Loading...
HomeMy WebLinkAbout1330 E Seventeenth St - Plan.. \ . . \ . . \ . . \ . . \ . . \ _ D o c u m e n t s - E n g i n e e r i n g \ S e a l s \ x S i g n a t u r e - C A . j p g · · · Bldg #101120775 Elect #20183938 APPROVALS: PLNG - P. Raj BLDG - K. Ahangian PUBLIC WORKS - Y. Soto ELECT - M. Smith 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 .. \ . . \ . . \ . . \ . . \ . . \ _ D o c u m e n t s - E n g i n e e r i n g \ S e a l s \ x S i g n a t u r e - C A . j p g 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K D A T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SETRACKING CONSTRUCTION SET GENERAL NOTES: 1. ALL SITE, PROJECT, AND BUILDING DETAILS ARE PROVIDED BY CUSTOMER OR GENERATED VIA SATELLITE IMAGERY FROM INFORMATION PROVIDED BY CUSTOMER. PANELCLAW IS NOT RESPONSIBLE FOR SITE INACCURACIES THAT COULD LEAD TO CHANGES TO THESE DRAWING DETAILS AND ARRAY LAYOUT CONFIGURATIONS. ALL INFORMATION CONTAINED WITHIN THESE DOCUMENTS ARE TO BE FIELD VERIFIED BY CUSTOMER AND INSTALLER. ANY CHANGES OR MODIFICATIONS TO THESE DOCUMENTS, CONTAINED INFORMATION, OR FINAL ARRAY AND MOUNTING SYSTEM INSTALLATIONS MUST BE SUBMITTED TO PANELCLAW AND OTHER PROJECT AUTHORITIES FOR APPROVAL. 2. REFER TO AND FOLLOW THE APPROPRIATE PANELCLAW INSTALLATION MANUALS AND PROCEDURES DURING THE INSTALLATION PROCESS. NOT FOLLOWING SUCH PROCEDURES AND METHODS COULD RESULT IN DAMAGE TO THE COMPONENTS OR MAY VOID THE PRODUCT WARRANTY. 3. ARRAY SETBACKS: ALL ARRAYS ARE REQUIRED TO BE SETBACK 4-FEET FROM ALL ROOF EDGES UNLESS OTHERWISE SPECIFIED AND CALLED OUT ON THE ARRAY DIAGRAMS ON THIS PAGE OR ON ADDITIONAL ARRAY BALLAST PAGES 4. REFER TO THE SPECIFIC ARRAY BALLAST SHEETS FOR BALLASTING REQUIREMENTS BASED ON THE PROVIDED SITE INFORMATION 5. SYSTEM PSF INCLUDES ALL PANELCLAW RACKING COMPONENTS, MECHANICAL ATTACHMENTS (IF APPLICABLE), PV MODULE AND BALLAST BLOCKS. FOR MAXIMUM SYSTEM POINT LOAD SUMMARY (PLS), REFER TO CALCULATIONS. 6. PANELCLAW AND/OR PANELCLAW CONSULTING ENGINEERS ARE NOT RESPONSIBLE FOR DETERMINING THE ADEQUACY OF THE STRUCTURE TO SUPPORT LOADS IMPOSED BY THE ARRAY AND MOUNTING SYSTEM. SUPPORT STRUCTURE TO BE CHECKED BY OTHERS 7. ALWAYS ALLOW 6” CLEARANCE BETWEEN NEIGHBORING SUBARRAYS, 6” BETWEEN SUBARRAYS AND ALL FIXED ROOF OBJECTS AND 4' BETWEEN SUBARRAYS AND ROOF EDGES. REFER TO LOCAL FIRE CODES AND ELECTRICAL CODES FOR ADDITIONAL REQUIREMENTS WHICH MAY GOVERN DESIGN. SUBARRAYS THAT USE A SEISMIC ANALYSIS METHOD OF DELTA MPV PER SEAOC OR ASCE 7-16 HAVE THEIR OWN CLEARANCE REQUIREMENTS. REFER TO THE BALLAST LAYOUT SHEETS WITHIN THIS DOCUMENT FOR DETAILS. 8. BALLAST BLOCK DIMENSIONS MUST CONFORM TO THE FOLLOWING SPECIFICATIONS: 3-3/4” THICK MAX., 7-5/8” ± 1/8” WIDTH, 15-5/8” ± 1/8” LENGTH. 9. IF AN ARRAY CLEARANCES TABLE APPEARS BELOW ON THIS PAGE, THE DESIGN UTILIZES THIRD PARTY SEISMIC NON-LINEAR RESPONSE ANALYSIS TO ESTIMATE MAXIMUM ARRAY SEISMIC DISPLACEMENT. THE PREDICTED MOVEMENT IS ONLY AN ESTIMATE. PANELCLAW IS NOT RESPONSIBLE OR LIABLE FOR ANY DAMAGES OR COSTS ASSOCIATED WITH PV ARRAY MOVEMENT INCLUDING MOVEMENT IN EXCESS OF THE CLEARANCES NOTED IN THIS DOCUMENT OR ANY REQUIREMENT TO REPOSITION THE ARRAYS IF MOVEMENT OCCURS. 10. DEFLECTORS MUST BE INSTALLED WHEN WINDS ARE EXPECTED TO EXCEED APPROX. 25% OF WIND SPEED DOCUMENTED IN SITE DESIGN CRITERIA TABLE. DEFLECTORS ARE REQUIRED ON ALL MODULES UNLESS OTHERWISE NOTED ON BALLAST LAYOUT PAGES. REQUIRED ARRAY CLEARANCES PER ASCE 7-16 CONDITION MINIMUM SEPARATION DISTANCE (IN.) BETWEEN SEPARATE SOLAR ARRAYS OF SIMILAR CONSTRUCTION (0.5) (Mpv)4 BETWEEN A SOLAR ARRAY AND A FIXED OBJECT ON THE ROOF OR SOLAR ARRAY OF DIFFERENT CONSTRUCTION (Mpv)7 BETWEEN A SOLAR ARRAY AND A ROOF EDGE WITH A QUALIFYING PARAPET (Mpv)7 BETWEEN A SOLAR ARRAY AND A ROOF EDGE WITHOUT A QUALIFYING PARAPET (2.0) (Mpv) >= 4ft 48 NOTE: SUFFICIENT SLACK IN ARRAY ELECTRICAL WIRING MUST BE PROVIDED TO ACCOMMODATE ALL POTENTIAL ARRAY MOVEMENT. SHEET INDEX NO.DESCRIPTION PC-1 COVER SHEET PC-2 PROJECT SUMMARY PC-3 ARRAY SITE MAP PC-4 TYPICAL ARRAY DIMENSIONS PC-5 ASSEMBLIES PC-6 RACKING COMPONENTS PC-7 BALLAST LEGEND PC-8 TO PC-22 BALLAST LAYOUT - 1 TO 15 Site Design Criteria - Flat Roof PV System Basis of Design Roof Live Load (psf)20(see footnote 1) Ground Snow Pg (psf)0 Flat Roof Snow Pf (psf)0 Snow Importance Factor (Is)1.0 Wind Design Data Basic Wind Speed (mph)95 Risk Category II Wind Exposure C Earthquake Design Data Risk Category II Importance Factor (Ie)1.00 Component Importance Factor (Ip)1.0 Mapped Acceleration Parameter (Ss)1.303 Mapped Acceleration Parameter(S1)0.464 Seismic Site Class D Design Spectral Acceleration Parameter (Sds)1.042 Design Spectral Acceleration Parameter (Sd1)0.568 Seismic Design Category (SDC)D Basic seismic-force-resisting system(s)ASCE 7 sec. 13.6.12 Base Design Shear = Fp x W 0.50 W Response Modification Factor (R)2.5 Analysis Procedure ASCE 7 sec. 13.6.12 Design Code (with local amendments)2022 CBC -ASCE 7 - 16 ALTERNATE DESIGN METHOD -SEAOC PV2 1. Roof Live Load only applicable to areas not covered by PV modules. Reference SEAOC Design Guidelines AERIAL PHOTO / SITE DIAGRAM THIS CONSTRUCTION SET PROVIDES THE RACKING LAYOUT FOR ALL ARRAYS WITH NUMBER OF BALLAST BLOCKS AND/OR MECHANICAL ATTACHMENTS BASED ON THE APPROVED STRUCTURAL CALCULATIONS FOR THE COMPLETED INSTALLED CONDITION OF THE SOLAR ARRAY. THE INSTALLER IS RESPONSIBLE FOR THE SAFETY AND CARE OF THE ARRAY DURING ALL PHASES OF INSTALLATION. THEREFORE, THE INSTALLER MUST MONITOR THE WEATHER FORECAST AND TAKE NECESSARY PRECAUTIONS (SEE GENERAL NOTE #10) TO TEMPORARILY SHORE/BRACE ALL ARRAYS DURING CONSTRUCTION UNTIL INSTALLATION IS COMPLETED IN CONFORMANCE WITH THIS APPROVED CONSTRUCTION SET AND THE PRODUCT INSTALLATION MANUAL (SEE GENERAL NOTE #2). THE INSTALLER HAS SOLE RESPONSIBILITY FOR THE MEANS, METHODS, AND TECHNIQUES OF CONSTRUCTION OF THE SOLAR ARRAY FOR COMPLIANCE WITH LAWS, REGULATIONS, AND CODES, AND FOR THE SAFETY OF CONSTRUCTION APPLICABLE TO THIS WORK. APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA COVER SHEET PC-11 24.05.14.1 v3.0.9405.5.2 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.3 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 26 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 13.78 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 60 Module Connector 52 Rail 71 Cam 52 Cam Claw 52 Deflector 26 Base Pad 0 Ballast Block 25 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 3079 ARRAY AREA (SQ. FT)892 ARRAY LOAD (PSF) 3.45 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.3 PC-101 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.3 PC-10 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 1 1 2 1 1 1 1 1 1 1 1 2 1 2 1 2 2 45.81' 29.92' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 8 SOUTH ASSEMBLY 8 MIDDLE ASSEMBLY 36 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.4 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 48 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 25.44 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 132 Module Connector 96 Rail 165 Cam 96 Cam Claw 96 Deflector 48 Base Pad 0 Ballast Block 48 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 5835 ARRAY AREA (SQ. FT)1641 ARRAY LOAD (PSF) 3.56 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.4 PC-111 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.4 PC-11 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 22 2 2 1 2 2 11 1 1 2 11 2 111 2 111 2 22 2 12 2 2 2 22.87' 134.82' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 34 SOUTH ASSEMBLY 34 MIDDLE ASSEMBLY 26 NORTH SOUTH ASSEMBLY 2 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.5 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 54 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 28.62 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 144 Module Connector 108 Rail 162 Cam 108 Cam Claw 108 Deflector 54 Base Pad 0 Ballast Block 26 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 5598 ARRAY AREA (SQ. FT)1847 ARRAY LOAD (PSF) 3.03 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.5 PC-121 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.5 PC-12 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 21 1 1 2 111111111111112 1 2 13.70' 134.82' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 36 SOUTH ASSEMBLY 36 MIDDLE ASSEMBLY 36 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.6 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 50 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 26.5 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 114 Module Connector 100 Rail 131 Cam 100 Cam Claw 100 Deflector 50 Base Pad 0 Ballast Block 35 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 5482 ARRAY AREA (SQ. FT)1715 ARRAY LOAD (PSF) 3.20 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.6 PC-131 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.6 PC-13 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 2 1 1 1 2 1 1 1 1 1 2 1 1 2 2 1 1 1 1 1 2 1 1 2 2 50.40' 52.40' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 14 SOUTH ASSEMBLY 14 MIDDLE ASSEMBLY 72 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.7 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 26 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 13.78 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 62 Module Connector 52 Rail 69 Cam 52 Cam Claw 52 Deflector 26 Base Pad 0 Ballast Block 19 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 2881 ARRAY AREA (SQ. FT)891 ARRAY LOAD (PSF) 3.23 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.7 PC-141 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.7 PC-14 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 1 1 1 1 2 1 1 1 2 1 2 2 27.46' 37.41'ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 10 SOUTH ASSEMBLY 10 MIDDLE ASSEMBLY 32 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.8 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 186 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 98.58 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 422 Module Connector 372 Rail 490 Cam 372 Cam Claw 372 Deflector 186 Base Pad 0 Ballast Block 122 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 20128 ARRAY AREA (SQ. FT)6381 ARRAY LOAD (PSF) 3.15 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.8 PC-151 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.8 PC-15 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 21 1 1 1 1 2 11 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 2 1 2 2 1 1 1 1 1 1 2 2 2 2 1 1 1 1 2 2 1 2 2 1 2 2 1 1 2 1 1 1 1 2 1 2 1 1 1 1 1 1 2 2 1 1 2 1 12 2 2 1 2 1 2 1 1 2 1 2 2 2 2 87.10' 134.82' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 50 SOUTH ASSEMBLY 50 MIDDLE ASSEMBLY 272 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.9 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 106 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 56.18 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 230 Module Connector 212 Rail 255 Cam 212 Cam Claw 212 Deflector 106 Base Pad 0 Ballast Block 48 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 10709 ARRAY AREA (SQ. FT)3639 ARRAY LOAD (PSF) 2.94 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.9 PC-161 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.9 PC-16 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 1 2 1 2 2 2 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 2 2 1 1 2 1 1 2 73.33' 67.38' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 18 SOUTH ASSEMBLY 18 MIDDLE ASSEMBLY 176 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.10 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 18 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 9.54 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 46 Module Connector 36 Rail 53 Cam 36 Cam Claw 36 Deflector 18 Base Pad 0 Ballast Block 17 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 2134 ARRAY AREA (SQ. FT)616 ARRAY LOAD (PSF) 3.46 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.10 PC-171 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.10 PC-17 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 11 1 1 1 1 2 2 2 2 27.46' 37.41'ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 8 SOUTH ASSEMBLY 8 MIDDLE ASSEMBLY 18 NORTH SOUTH ASSEMBLY 2 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.11 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 34 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 18.02 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 80 Module Connector 68 Rail 95 Cam 68 Cam Claw 68 Deflector 34 Base Pad 0 Ballast Block 42 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 4336 ARRAY AREA (SQ. FT)1166 ARRAY LOAD (PSF) 3.72 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.11 PC-181 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.11 PC-18 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 21 2 1 1 1 1 2 2 1 21 12 22 22 22 22 12 1 2 59.57' 37.41' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 10 SOUTH ASSEMBLY 10 MIDDLE ASSEMBLY 46 NORTH SOUTH ASSEMBLY 2 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.12 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 36 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 19.08 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 86 Module Connector 72 Rail 103 Cam 72 Cam Claw 72 Deflector 36 Base Pad 0 Ballast Block 32 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 4190 ARRAY AREA (SQ. FT)1234 ARRAY LOAD (PSF) 3.40 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.12 PC-191 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.12 PC-19 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 21 2 1 2 1 2 1 1 1 1 2 2 1 1 1 1 1 2 2 1 1 2 27.46' 52.40'ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 14 SOUTH ASSEMBLY 14 MIDDLE ASSEMBLY 44 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: SITE MAP A PC-2NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA PROJECT SUMMARY PC-21 24.05.14.1 v3.0.9405.5.2 clawFRplus 10 Degree - 29 cm PROJECT PART QUANTITY ITEM PART NUMBER QTY Base 500050202 1994 BASE, 02, CFR Module Connector 500063304 1700 MODULE CONNECTOR, 1150, 10D, CFRP Rail 2000895 2308 RAIL, 2500, CFR Cam 5000630 1700 CAM, 10D, CFRP Cam Claw 2000854 1700 CAM CLAW, CFRP Deflector 200088705 850 DEFLECTOR, 10D, 2300, CFR Bolt 2000697 8459 BLT, HEX FLG, TRI, M6X16, GR8.8, PATCH Base Pad 2000678 0 PAD, BASE, CFR CONCRETE MASONRY UNIT N/A 656 BLOCK, CONCRETE, 32.6 LB, - Xin x 8in x 16in NOMINAL, PARTNER SUPPLIED, SEE INSTALLATION MANUAL APPROVED FOR CONSTRUCTION PROJECT SUMMARY MODULE TYPE CANADIAN SOLAR CS6W-530MB-AG MODULE DIMENSIONS (IN.)89.21 X 44.65 X 1.38 NUMBER OF MODULES 850 MODULE WATTAGE (W STC)530 SYSTEM SIZE (kW STC)450.5 SYSTEM WEIGHT (LB)95399 SYSTEM AREA (SQ FT.)29146 AGGREGATE SYSTEM LOAD (PSF)3.27 NUMBER OF ARRAYS 15 ARRAY TILT (DEG)8.99 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 Roof 1 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.13 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 8 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 4.24 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 24 Module Connector 16 Rail 27 Cam 16 Cam Claw 16 Deflector 8 Base Pad 0 Ballast Block 16 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 1234 ARRAY AREA (SQ. FT)273 ARRAY LOAD (PSF) 4.52 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.13 PC-201 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.13 PC-20 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 3 2 3 2 222 13.70' 29.92' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 4 SOUTH ASSEMBLY 4 MIDDLE ASSEMBLY 4 NORTH SOUTH ASSEMBLY 4 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.14 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 10 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 5.3 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 26 Module Connector 20 Rail 30 Cam 20 Cam Claw 20 Deflector 10 Base Pad 0 Ballast Block 15 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 1368 ARRAY AREA (SQ. FT)342 ARRAY LOAD (PSF) 4.00 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.14 PC-211 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.14 PC-21 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 2 1 2 2 2 2 2 18.28' 22.42' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 6 SOUTH ASSEMBLY 6 MIDDLE ASSEMBLY 8 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.15 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 6 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 3.18 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 18 Module Connector 12 Rail 20 Cam 12 Cam Claw 12 Deflector 6 Base Pad 0 Ballast Block 13 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 958 ARRAY AREA (SQ. FT)205 ARRAY LOAD (PSF) 4.68 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.15 PC-221 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.15 PC-22 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 3 3 23 2 9.11' 22.42' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 6 SOUTH ASSEMBLY 6 MIDDLE ASSEMBLY 0 NORTH SOUTH ASSEMBLY 0 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: # RACKING CONSTRUCTION SET NOTES: 1.ALL DIMENSIONS SHOWN ARE BASED UPON INFORMATION PROVIDED TO PANELCLAW. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION OF THE SOLAR ARRAY. NOTIFY PANELCLAW OF ANY DISCREPANCIES. APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA ARRAY SITE MAP PC-32 24.10.25.1 v3.0.9405.9.5 CM ROOF NAME ROOF SETBACK (FT.) ROOF HEIGHT (FT) PARAPET HEIGHT (FT) ROOF TILT (DEG) Roof 1 10.00 20.00 2.0 2 KEEPOUT NAME KEEPOUT CLEARANCE (FT.) KEEPOUT HEIGHT (IN.) Group 1 4 24 Group 2 4 96 Group 3 4 72 Group 4 4 48 Group 5 0.5 6 Group 6 2 24 3 2 Re v i s e d M o d u l e a n d L a y o u t GZ 20 2 4 - 1 1 - 0 4 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 180' 15' 79'1'60'1'39' 105' 40' 219' 319' 134' 23'2'24' 56' 1' 9' 1'2'6' 51' 6'2'1' 9' 0' 12' 1' 33' 1 2 3 4 5 6 7 8 9 10 11 12 TROY E.TURLEY 11/ 1 3 / 2 0 2 4 24-0242-3081.1 1330 E Seventeenth St4/10/2025 'L' RAIL INSTALLATION: USE THE OUTER SET OF HOLES WHEN INSTALLING RAILS BETWEEN MODULES. RAIL ON “L” SPACING IS ALWAYS ON TOP OF RAIL ON “S” SPACING. THIS INSTALLATION SEQUENCE IS CRITICAL TO SYSTEM PERFORMANCE. FOR MORE INFORMATION REVIEW THE INSTALLATION MANUAL AND VIDEOS. A (REPEAT DIMENSION EAST-WEST) PL (PANEL LENGTH) M (PROJECTED PANEL WIDTH) B (REPEAT DIMENSION NORTH-SOUTH) C J PT P D PW D ° O W K X 18 mm (0.709 in)N G 32 . 9 m m ( 1 . 2 9 5 i n ) S (ON-MODULE BASE SPACING) L (BETWEEN-MODULE BASE SPACING)R AEBE RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY TOP VIEW B NTSSCALE: ARRAY CROSS SECTION VIEW A NTS SCALE: RAIL DETAIL C NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 24.05.14.1 v3.0.9405.5.2 INSTALLED ARRAY DIMENSIONS A B C D G J K M N O P R W X Theta (DEG)D/J (#:1)G.C.R.* mm 2284 1398 121 278 116 177 209 1120 81 59 92 516 253 137 8.99 1.57 0.81UNITS inches 89.92 55.05 4.75 10.96 4.56 6.97 8.23 44.10 3.20 2.31 3.61 20 5/16 9.95 5.39 8.99 1.57 0.81 * G.C.R = (PW) / B INSTALLATION MEASUREMENTS AEBE S L CAM SPACING* mm 486 1234 1050 53UNITS inches 19 1/8 48 9/16 41 5/16 2 1/8 *CAM SPACING SHOWN ON ASSEMBLIES PAGE. MODULE DIMENSIONS PL PW PT mm 2266 1134 35UNITS inches 89.21 44.65 1.38 PC-4 PC-4 PC-4 TYPICAL ARRAY DIMENSIONS PC-4 APPROVED FOR CONSTRUCTION 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA ASSEMBLIES PC-51 24.05.14.1 v3.0.9405.5.2 APPROVED FOR CONSTRUCTION PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 274 SOUTH ASSEMBLY 274 MIDDLE ASSEMBLY 1132 NORTH SOUTH ASSEMBLY 20 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 53UNITS inches 2 1/8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 NOTE: EXAMPLE BALLASTING SHOWN ON THIS PAGE IS FOR REFERENCE ONLY AND DO NOT REFLECT TYPICAL BALLAST PLACEMENT. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST REQUIREMENTS. BASE RAIL DEFLECTOR CAM BRACKET AND CAM CLAW TRANSPARENT MODULE MODULE CONNECTOR RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM BRACKET C NTS SCALE: CAM CLAW B NTS SCALE: RAIL F NTS SCALE: BASE D NTS SCALE: MODULE CONNECTOR E NTSSCALE: DEFLECTOR G NTS SCALE: EXAMPLE RAIL AND BLOCK CONFIGURATION A NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 APPROVED FOR CONSTRUCTION PC-6 RACKING COMPONENTS 24.05.14.1 v3.0.9405.5.2 PC-6 PC-6 PC-6 PC-6 PC-6 PC-6PC-6 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 MECHANICAL ATTACHMENT AT INDICATED LOCATION NOTE: EXAMPLE BALLAST AND ATTACHMENTS SHOWN ON THIS PAGE ARE FOR REFERENCE ONLY. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST/ATTACHMENT REQUIREMENTS. BALLAST QUANTITY: "#"=QUANTITY OF BALLAST BLOCK INSTALLED CENTERED UNDER MODULE IF NO BALLAST QUANTITY SHOWN, DO NOT PLACE BALLAST SEE INSTALLATION MANUAL FOR NOTES ON INSTALLING MORE THAN FOUR BALLAST BLOCKS PER MODULE DO NOT INSTALL ADDITIONAL RAIL TO HOLD BALLAST ON MODULES WITH NO BALLAST SHOWN. MODULES LONGER THAN 2100 MM WITH 7 OR 8 BALLAST BLOCKS REQUIRE TWO (2) RAILS. 6 2 2 2 4 2 85 5 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY TOP VIEW B NTSSCALE: ARRAY CROSS SECTION VIEW A NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 PC-7 BALLAST LEGEND APPROVED FOR CONSTRUCTION 24.05.14.1 v3.0.9405.5.2 PC-7 PC-7 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.1 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 46 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 24.38 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 114 Module Connector 92 Rail 149 Cam 92 Cam Claw 92 Deflector 46 Base Pad 0 Ballast Block 113 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 7745 ARRAY AREA (SQ. FT)1576 ARRAY LOAD (PSF) 4.92 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.1 PC-81 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.1 PC-8 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 31 2 2 3 4 3 2 3 4 2 3 4 1 2 2 1 2 1 34 1 1 2 12 1 5 1 26 4 2 1 24 3 2 4 24 26 3 82.51' 44.90' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 16 SOUTH ASSEMBLY 16 MIDDLE ASSEMBLY 54 NORTH SOUTH ASSEMBLY 6 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.2 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT) 2.0 ROOF TILT (DEG) 2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 196 MODULE POWER (W) 530 ARRAY OUTPUT (Kw) 103.88 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 436 Module Connector 392 Rail 488 Cam 392 Cam Claw 392 Deflector 196 Base Pad 0 Ballast Block 85 LOADING DETAILS SINGLE MODULE WT (LB) 71.0 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 19724 ARRAY AREA (SQ. FT)6727 ARRAY LOAD (PSF) 2.93 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.) 4 CONDITION 2 (in.) 7 CONDITION 3 (in.) 7 CONDITION 4 (in.) 48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.2 PC-91 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.2 PC-9 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 2 2 1 1 2 1 2112 21 2 73.33' 127.33' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 40 SOUTH ASSEMBLY 40 MIDDLE ASSEMBLY 308 NORTH SOUTH ASSEMBLY 4 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA ASSEMBLIES PC-51 24.05.14.1 v3.0.9405.5.2 APPROVED FOR CONSTRUCTION PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 274 SOUTH ASSEMBLY 274 MIDDLE ASSEMBLY 1132 NORTH SOUTH ASSEMBLY 20 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 53UNITS inches 2 1/8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 NOTE: EXAMPLE BALLASTING SHOWN ON THIS PAGE IS FOR REFERENCE ONLY AND DO NOT REFLECT TYPICAL BALLAST PLACEMENT. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST REQUIREMENTS. BASE RAIL DEFLECTOR CAM BRACKET AND CAM CLAW TRANSPARENT MODULE MODULE CONNECTOR RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM BRACKET C NTS SCALE: CAM CLAW B NTS SCALE: RAIL F NTS SCALE: BASE D NTS SCALE: MODULE CONNECTOR E NTSSCALE: DEFLECTOR G NTS SCALE: EXAMPLE RAIL AND BLOCK CONFIGURATION A NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 APPROVED FOR CONSTRUCTION PC-6 RACKING COMPONENTS 24.05.14.1 v3.0.9405.5.2 PC-6 PC-6 PC-6 PC-6 PC-6 PC-6PC-6 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t MM 20 2 4 - 0 5 - 2 8 TROY E.TURLEY 24-0242-3081 7-19-24 1330 E Seventeenth St4/10/2025 INVERTER UL1741-SB COMPLIANT ANSI ELEMENT #Pickup Real Level Delay (sec)Curve Description 27 243.87 422.4V 88.0%21.00 Slow UV 27 138.56 240V 50.0%1.50 Fast UV 59 304.84 528V 110.0%13.00 Slow OV 59 332.55 576V 120.0%0.16 Fast OV 81U-1 57.00 57.0Hz 95.0%0.16 Fast UF 81U-2 58.50 58.5Hz 97.5%300.00 Slow UF 81O-1 62.00 62Hz 103.3%0.16 Fast OF 81O-2 60.10 60.1Hz 100.2%300.00 Slow OF PF Set Point 1.00 Power Factor Control Var Control OFF Reactive Power Control Ramp Rate 10%/1 sec dkw / dt Freq Control OFF Speed Control .. \ . . \ . . \ . . \ . . \ . . \ _ D o c u m e n t s - E n g i n e e r i n g \ S e a l s \ x S i g n a t u r e - C A . j p g 1330 E Seventeenth St4/10/2025 “” ” ” 1330 E Seventeenth St4/10/2025 PF-MH-IFP#2 1330 E Seventeenth St4/10/2025 ⁰ ⁰ ⁰ ⁰ PF-MH-IFP#3 1330 E Seventeenth St4/10/2025 TABLE 250.102(C)(1) SIZE OF LARGEST UNGROUNDED CONDUCTOR OR EQUIVALENT AREA FOR PARALLEL CONDUCTORS (AWG/KCMIL) SIZE OF GROUNDED CONDUCTOR OR BONDING JUMPER (AWG/KCMIL) COPPER ALUMINUM OR COPPER-CLAD ALUMINUM COPPER ALUMINUM OR COPPER-CLAD ALUMINUM 2 OR SMALLER 1/0 OR SMALLER 8 6 1 OR 1/0 2/0 OR 3/0 6 4 2 OR 2/0 4/0 OR 250 4 2 OVER 3/0 THROUGH 350 OVER 250 THROUGH 500 2 1/0 OVER 350 THROUGH 600 OVER 500 THROUGH 900 1/0 3/0 OVER 600 THROUGH 1100 OVER 900 THROUGH 1750 2/0 4/0 OVER 1100 OVER 1750 REFER TO NOTES IN NEC TABLE 250.102(C)(1) TABLE 250.122 OVERCURRENT DEVICE CIRCUIT NOT EXCEEDING (AMPERES) SIZE (AWG OR KCMIL) COPPER ALUMINUM 15 14 12 20 12 10 60 10 8 100 8 6 200 6 4 300 4 2 400 3 1 500 2 1/0 600 1 2/0 800 1/0 3/0 1000 2/0 4/0 1200 3/0 250 1600 4/0 350 2000 250 400 2500 350 600 3000 400 600 4000 500 750 1330 E Seventeenth St4/10/2025 MAXIMUM CONDUIT HARDWARE SPACING CONDUIT TYPE ENCLOSURE TO SUPPORT (A) SUPPORT TO SUPPORT (B)NEC ARTICLE ELECTRICAL METALLIC TUBING (EMT)3'10'358 INTERMEDIATE METAL CONDUIT (IMC)3'10'342 RIGID METAL CONDUIT (RMC)3'10'344 LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC)1'4.5'350 PVC (SCH40 & 80) [0.5" - 1"]3'3'352 PVC (SCH40 & 80) [1.25" - 2"]3'5'352 PVC (SCH40 & 80) [2.5" - 3"]3'6'352 PVC (SCH40 & 80) [3.5" - 5"]3'7'352 PVC (SCH40 & 80) [6"]3'8'352 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS PV SYSTEM INSTALLER INFORMATION INSTALLATION COMPANY: EMERGENCY PHONE #: WARNING: PHOTOVOLTAIC POWER SOURCE 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 PARTNER SECTION ELECTRICAL DATA | STC* Nominal Max. Power (Pmax) Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Module CS6W-520MB-AG 520 W 40.5 V 12.84 A 48.4 V 13.70 A 20.2% Bifacial Gain** 5%546 W 40.5 V 13.48 A 48.4 V 14.39 A 21.2% 10%572 W 40.5 V 14.12 A 48.4 V 15.07 A 22.3% 20%624 W 40.5 V 15.41 A 48.4 V 16.44 A 24.3% CS6W-525MB-AG 525 W 40.7 V 12.90 A 48.6 V 13.75 A 20.4% Bifacial Gain** 5%551 W 40.7 V 13.55 A 48.6 V 14.44 A 21.4% 10%578 W 40.7 V 14.21 A 48.6 V 15.13 A 22.5% 20%630 W 40.7 V 15.48 A 48.6 V 16.50 A 24.5% CS6W-530MB-AG 530 W 40.9 V 12.96 A 48.8 V 13.80 A 20.6% Bifacial Gain** 5%557 W 40.9 V 13.62 A 48.8 V 14.49 A 21.7% 10%583 W 40.9 V 14.26 A 48.8 V 15.18 A 22.7% 20%636 W 40.9 V 15.55 A 48.8 V 16.56 A 24.8% CS6W-535MB-AG 535 W 41.1 V 13.02 A 49.0 V 13.85 A 20.8% Bifacial Gain** 5%562 W 41.1 V 13.68 A 49.0 V 14.54 A 21.9% 10%589 W 41.1 V 14.34 A 49.0 V 15.24 A 22.9% 20%642 W 41.1 V 15.62 A 49.0 V 16.62 A 25.0% CS6W-540MB-AG 540 W 41.3 V 13.08 A 49.2 V 13.90 A 21.0% Bifacial Gain** 5%567 W 41.3 V 13.73 A 49.2 V 14.60 A 22.1% 10%594 W 41.3 V 14.39 A 49.2 V 15.29 A 23.1% 20%648 W 41.3 V 15.70 A 49.2 V 16.68 A 25.2% CS6W-545MB-AG 545 W 41.5 V 13.14 A 49.4 V 13.95 A 21.2% Bifacial Gain** 5%572 W 41.5 V 13.80 A 49.4 V 14.65 A 22.3% 10%600 W 41.5 V 14.46 A 49.4 V 15.35 A 23.3% 20%654 W 41.5 V 15.77 A 49.4 V 16.74 A 25.5% * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell tempe- rature of 25°C. ** Bifacial Gain: The additional gain from the back side compared to the power of the front side at the standard test condition. It depends on mounting (structure, height, tilt angle etc.) and albedo of the ground. ENGINEERING DRAWING (mm) Rear View ELECTRICAL DATA | NMOT* Nominal Max. Power (Pmax) Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) CS6W-520MB-AG 390 W 38.0 V 10.27 A 45.7 V 11.05 A CS6W-525MB-AG 394 W 38.2 V 10.32 A 45.9 V 11.09 A CS6W-530MB-AG 397 W 38.3 V 10.38 A 46.1 V 11.13 A CS6W-535MB-AG 401 W 38.5 V 10.42 A 46.3 V 11.17 A CS6W-540MB-AG 405 W 38.7 V 10.47 A 46.5 V 11.21 A CS6W-545MB-AG 409 W 38.9 V 10.52 A 46.7 V 11.25 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. 35 23 Mounting Hole CS6W-530MB-AG / I-V CURVES 7 10 R 9 14 R ELECTRICAL DATA Operating Temperature -40°C ~ +85°C Max. System Voltage 1500 V (IEC/UL) or 1000 V (IEC/UL) Module Fire Performance TYPE 29 (UL 61730) or CLASS C (IEC61730) Max. Series Fuse Rating 30 A Class A Power Tolerance Power Bifaciality*70 % * Power Bifaciality = Pmaxrear / Pmaxfront, both Pmaxrear and Pmaxfront are tested under STC, Bifaciality Tolerance: ± 5 % MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement Dimensions Weight 32.2 kg (71.0 lbs) Front Glass 2.0 mm heat strengthened glass with anti- Back Glass 2.0 mm heat strengthened glass Frame Anodized aluminium alloy J-Box IP68, 3 bypass diodes Cable 4.0 mm² (IEC), 12 AWG (UL) Cable Length (Including Connector) 410 mm (16.1 in) (+) / 290 mm (11.4 in) (-) or customized length* Connector T4 or MC4 series Per Pallet 30 pieces Per Container (40‘ HQ)600 pieces or 540 pieces (only for US) * For detailed information, please contact your local Canadian Solar sales and technical representatives. Frame Cross Section A-A TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A V A 1000 W/m 2 800 W/m 2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 06 55 05 54 04 53 03 52 02 51 01 5 06 55 05 54 04 53 03 52 02 51 01 5 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 ~ + 10 W products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. have professional skills and please carefully read the safety and installation instructions before using our PV modules. 35 AA 1105 1134 50 50 6-5Grounding Hole 400 790 1155 8-10x7Mounting Hole(tracker) 4-14x9 Mounting Hole 2266 Feb. 2022 | All rights reserved | PV Module Product Datasheet v2.0_F42_J2_NACSI SOLAR (USA) CO., LTD. C M Y CM MY CY CMY K CS-Datasheet-BiHiKu6_CS6W-MB-AG_v2.0_F42_J1_NA.pdf 2 1/21/2022 9:51:49 AM 1330 E Seventeenth St4/10/2025 MORE POWER MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 545 W 545 W Minimizes micro-crack impacts Heavy snow load up to 5400 Pa, wind load up to 2400 Pa* Better shading tolerance 30 12Years Years BiHiKu6 520 W ~ 545 W BIFACIAL MONO PERC CS6W-520|525|530|535|540|545MB-AG FRONT BACK Compatible with mainstream trackers, cost effective product for utility power plant Up to 12.3 % lower LCOE Up to 5.2 % lower system cost PRODUCT CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system ISO 45001: 2018 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES* products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. *According to the applicable Canadian Solar Limited Warranty Statement. Enhanced Product Warranty on Materials and Workmanship* Linear Power Performance Warranty* 1st year power degradation no more than 2% Subsequent annual power degradation no more than 0.45% IEC 61215 / IEC 61730 / CE / INMETRO / MCS / UKCA CEC listed (US California) UL 61730 / IEC 61701 / IEC 62716 / IEC 60068-2-68 Take-e-way C M Y CM MY CY CMY K CS-Datasheet-BiHiKu6_CS6W-MB-AG_v2.0_F42_J1_NA.pdf 1 1/21/2022 9:51:49 AM RACKING CONSTRUCTION SET 1330 E Seventeenth St4/10/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1330 E Seventeenth St4/10/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1330 E Seventeenth St4/10/2025 15445 Innovation Drive San Diego, CA 92128 Planning and Building Agency 20 Civic Center Plaza Santa Ana CA 92701 2nd April, 2025 Dear Kathy Hernandez, This letter pertains to the permit for 1330 E Seventeenth St for the installation of a rooftop PV system in the city of Santa Ana. The permit was originally applied for under the Powerflex contractor license, and we would like to request that it be transferred to our subcontractors - Barnum & Celillo Electric, Inc., who will be performing the required work at the site. Their license number is 599724 and I have uploaded a copy of their city business license as well. Please let me know if you require any additional information or documents as we work towards the issuance of this permit. Thank you for your assistance. Sincerely, 1330 E Seventeenth St4/10/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 www.ctsaz.com Job No. 24-0242-3081.1 Sheet No. Cover By DML/TET Date 11/13/24 CLIENT: 1600 Osgood Street Suite 2023 North Andover, MA 01845 PROJECT: CA Target T0286 Santa Ana 1330 17th Street Santa Ana, CA GENERAL INFORMATION: BUILDING CODE: 2022 CBC, ASCE 7-16 With SEAOC PV1-2012 and PV2-2017 11/13/202 4 1330 E Seventeenth St4/10/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 www.ctsaz.com Date: November 13, 2024 Mr. Ryan Heil PanelClaw 1600 Osgood Street, Ste. 2023 North Andover, MA 01845 RE: Evaluation of PanelClaw system Project Name: CA Target T0286 Santa Ana CTS Job No.: 24-0242-3081.1 Per the request of Ryan Heil at PanelClaw, CTS was asked to review the PanelClaw racking system with respect to the system’s ability to resist uplift and sliding caused by wind and seismic loads. Wind Evaluation: PanelClaw has provided CTS with wind tunnel testing performed by CPP, Inc. The system tested was the “clawFRplus 10 Degree” system. This system consists of photovoltaic panels installed at a 10 degree tilt onto support assemblies. The support assemblies consist of a support frame for the PV panels, wind deflectors and areas for additional mass/weight as required for the ballast loads. The wind tunnel testing was performed per Chapter 31 of ASCE 7-16. The parameters of the testing were a flat roof system in both Exposure B and C on a building with and without parapets. The testing has resulted in pressure and/or force coefficients that were applied to the velocity pressure qz in order to obtain the wind loads on the PV system. From the wind load results it is then possible to calculate the ballast loads required to resist the uplift and sliding forces. PanelClaw has provided CTS with the excel tool that was developed to obtain the uplift and sliding forces. CTS has reviewed this tool and the wind forces obtained to find that the amounts of ballast provided are within the values required. Furthermore, CTS agrees with the methodologies used to develop the uplift and sliding forces for the “clawFRplus 10 Degree” system per the wind tunnel testing results. Seismic Evaluation for Arrays: 1.2-1.12 Calculations have been provided utilizing the method found in SEAOC PV1 -2012, Section 9 for the use of non -linear response history analysis to determine the seismic displacement of non-structural components located on a roof per SEAOC PV-2012 and ASCE Section 13.6.12. These calculations have determined that the friction generated from the ballast (allowed per CBC Section 1613.3 and ASCE Section 13.6.12 per Section 13.4 exception ) is sufficient to restrict displacement due to seismic forces to acceptable distances, and that no mechanical attachments are required. 1330 E Seventeenth St4/10/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 www.ctsaz.com Seismic Evaluation for Array 1.1: CTS was asked to review the PanelClaw system to determine attachments required to resist seismic loading of the ballasted solar support system on the roof of the existing building. Following CBC Load Combination 16-16 and ASCE Section 2.4.5, the Dead Load value has been reduced by subtracting the vertical component of the seismic forces (0.6*D - 0.14Sds*D). The contribution of friction due to the component weight was not considered to resist lateral forces caused by seismic loads per ASCE Section 13.4. Utilizing this method, calculations have been provided for the number of mechanical attachments that are required to resist seismic forces that are applied to the system. Conclusion: Therefore, it has been determined that the system as provided by PanelClaw is sufficient to resist both wind and seismic loads at this project. Please contact CTS with any questions regarding this letter or attachments. Respectfully, Dylan Le Troy Turley, SE, PE, LEED AP Structural Designer Partner 11/13/202 4 1330 E Seventeenth St4/10/2025 Partner Name:PowerFlex Project Name:CA Target T0286 Santa Ana Project Location:1330 17th Street, Santa Ana, CA, USA Racking System:clawFRplus 10 Degree Structural Calculations for Roof-Mounted Solar Array Submittal Release: Rev 2 Engineering Seal 11/04/2024 APPROVED FOR CONSTRUCTION 11/13/202 4 1330 E Seventeenth St4/10/2025 Table of Contents Section:Page # 11/04/2024 APPROVED FOR CONSTRUCTION 2 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information 4 1.1 General 4 1.2 Building Information 4 1.3 Structural Design Information 5 2.0 Snow Load 6 2.1 Snow Load Data 6 2.2 Snow Load Per Module 6 3.0 Wind Load 7 3.1 Wind Load Data 7 3.2 Roof / Array Zone Map 7 3.3 Wind Design Equations 7 4.0 Design Loads - Dead 8 4.1 Dead Load of the Arrays 8 5.0 Design Loads - Wind 9 5.1.1 Global Wind Uplift Summary Table 9 5.1.2 Global Wind Shear Summary Table 10 6.0 Design Loads - Downward 11 6.1 Downward Wind Load Calculation 11 6.2 Racking Dimensions for Point Loads 11 6.3 Point Load Summary 12 7.0 Design Loads - Seismic 13 7.1 Seismic Load Data 13 7.2 Seismic Design Equations 13 7.3 Lateral Seismic Force Check 14 7.3.1 Seismic Displacement of Unattached Solar Arrays:15 7.4 Vertical Seismic Force Check 17 1330 E Seventeenth St4/10/2025 Appendix: A. Wind Tunnel Tests and Load Analysis for PANELCLAW ROOF MOUNT 10° TILT SOUTH-FACING, CPP Project 19784, Dated 16 April 2024. B. Seismic displacement demand of unattached (ballast-only) solar arrays 11/04/2024 APPROVED FOR CONSTRUCTION 3 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 1.0 Project Information: 1.1 General: Project Name:CA Target T0286 Santa Ana Project Location:1330 17th Street, Santa Ana, CA, USA Racking System:clawFRplus 10 Degree Module:CANADIAN SOLAR CS7N-690TB-AG Module Weight:83.56 lbs. Module Tilt:7.81 deg. Module Width:51.30 in. Module Length:93.86 in. Module Area:33.44 sq.ft. Ballast Block Weight:32.60 lbs. 1.2 Building Information: Roof Name Height (ft.)Parapet Height (ft.) Roof 1 20 2.0 Sub-Array Name Pitch (deg.)Membrane Material Coeff. of Friction (μ) 1.1 2 PVC 0.71 1.2 2 PVC 0.71 1.3 2 PVC 0.71 1.4 2 PVC 0.71 1.5 2 PVC 0.71 1.6 2 PVC 0.71 1.7 2 PVC 0.71 1.8 2 PVC 0.71 1.9 2 PVC 0.71 1.10 2 PVC 0.71 1.11 2 PVC 0.71 1.12 2 PVC 0.71 11/04/2024 APPROVED FOR CONSTRUCTION 4 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 1.0 Project Information (Cont.): 1.3 Structural Design Information: ASCE Code:ASCE 7-16 Building Code:2022 CBC Risk Cat.:II Basic Wind Speed (V):95 mph Exposure Category:C Ground Snow Load (Pg):0 psf Is:1 Site Class:D Short Period Spectral Resp. (5%) (Ss):1.303 1s Spectral Response (5%) (S1):0.464 Ie:1 Ip:1 11/04/2024 APPROVED FOR CONSTRUCTION 5 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 2.0 Snow Load: Snow Calculations per ASCE 7-16, Chapter 7 2.1 Snow Load Data: Ground Snow Load (Pg)=0.00 psf (ASCE, Figure 7.2-1) Exposure Factor (Ce)=1 (ASCE, Table 7.3-1) Thermal Factor (Ct)=1.2 (ASCE, Table 7.3-2) Importance Factor (Is)=1 (ASCE, Table 1.5-2) Flat Roof Snow Load (Pf) =0.7*Pg*Ce*Ct*Is=0.00 psf (ASCE 7.3-1) Min Snow Load for Low Slope Roof =Pg*Is =0.00 psf (ASCE 7.3.4) Snow Load on Array (SLA) =0.00 psf SLA Fig. 2.1 - Uniform Roof Snow Load on Array 2.2 Snow Load Per Module: Snow Load per Module (SLM) =Module Projected Area SLA Where; Module Projected Area (Amp) = Module Area * Cos(Module Tilt) Where; Module Area =33.44 sq.ft. Module Tilt =7.81 deg. Amp =33.13 sq.ft. SLM =   Amp     SLA   = 0.00     lbs. 11/04/2024 APPROVED FOR CONSTRUCTION 6 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 3.0 Wind Load: Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 3.1 Wind Load Data: Basic Wind Speed (Vult) =95 mph (ASCE, Fig. 26.5-1) Exposure Category:C (ASCE, Sec. 26.7.3) Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) Exposure Coefficient (Kz) =0.90 (ASCE, Table 26.10-1) Ground Elevation Factor (Ke) =0.99 (ASCE, Table 26.9-1) Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =17.61 psf (ASCE, Eqn. 26.10-1) 3.2 Roof / Array Zone Map: Figure 3-1. South corner zones – 90-180° wind directions Figure 3-2. North corner zones – 0- 90° wind direction Roof Zone Map Dimensions per CPP Wind Tunnel Study Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) 20 20.00 17.61 *LB = Characteristic length per wind tunnel study 3.3 Wind Design Equations: FL = qz Aref GCL FL = sum of lift on panel and deflector. FD = qz Aref GCD FD = sum of drag on panel and deflector. FL - D Companion = qz Aref GCL - D Companion FD - L = The accompanying uplift corresponding to maximum drag. Where qz = Velocity Pressure (Ref. Section 3.1, Wind Load) Aref = Module Area (Ref. Section 1.1, General) GCL GCD , GCL-D Companion= Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) 11/04/2024 APPROVED FOR CONSTRUCTION 7 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 4.0 Design Loads - Dead: There are two categories of dead load used to perform the structural analysis of the PanelClaw racking system; Dead Load of the Array (DLA) and Dead Load of the Components (DLC). DLA is defined as the weight of the entire array including all of the system components and total ballast used on the array. DLC is defined as the weight of the modules and the racking components within an array. The DLC does not include the ballast used to resist loads on this array. 4.1 Dead Load of the Arrays: Array Information Results Sub- Array Name Number of Modules DLC (lbs.) DLA (lbs.) DLC (lbs.)/module Sub- Array Area (ft.^2) Sub-Array Roof Pressure (DLC) (psf) Sub-Array Roof Pressure (DLA) (psf) Max Allowable Pressure on Roof (psf) Acceptable? 1.1 36 3,690 6,037 102 1,453 2.54 4.16 6.00 Yes 1.2 163 16,232 20,144 100 6,587 2.46 3.06 6.00 Yes 1.3 23 2,306 3,447 100 929 2.48 3.71 6.00 Yes 1.4 34 3,486 4,725 103 1,368 2.55 3.45 6.00 Yes 1.5 40 4,071 5,506 102 1,611 2.53 3.42 6.00 Yes 1.6 38 3,800 5,300 100 1,535 2.48 3.45 6.00 Yes 1.7 24 2,398 3,310 100 969 2.47 3.42 6.00 Yes 1.8 146 14,604 20,146 100 5,898 2.48 3.42 6.00 Yes 1.9 84 8,356 10,508 99 3,395 2.46 3.10 6.00 Yes 1.10 22 2,207 3,250 100 888 2.49 3.66 6.00 Yes 1.11 30 3,020 4,324 101 1,211 2.49 3.57 6.00 Yes 1.12 13 1,312 2,127 101 524 2.50 4.06 6.00 Yes Total:  653 65,481 lbs.88,823 lbs. *Racking component weight range between 13 to 15 pounds per module Table 4.1 - Array Dead Loads and Roof Pressures 11/04/2024 APPROVED FOR CONSTRUCTION 8 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 5.0 Design Loads - Wind: 5.1.1 Global Wind Uplift Summary Table: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL = Total Wind Uplift (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Calculated Factor of Safety* Check 1.1 7,604 6,037 350 2,276 1.82 OK 1.2 19,681 20,144 N/A 0 1.71 OK 1.3 3,416 3,447 N/A 0 1.68 OK 1.4 4,548 4,725 N/A 0 1.73 OK 1.5 5,490 5,506 N/A 0 1.67 OK 1.6 5,267 5,300 N/A 0 1.68 OK 1.7 3,281 3,310 N/A 0 1.68 OK 1.8 20,097 20,146 N/A 0 1.67 OK 1.9 10,309 10,508 N/A 0 1.70 OK 1.10 3,221 3,250 N/A 0 1.68 OK 1.11 4,288 4,324 N/A 0 1.68 OK 1.12 1,950 2,127 N/A 0 1.82 OK Total:89,152 lbs.88,823 lbs. 2,276 lbs. Table 5.1 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(.6)WIND LOAD 11/04/2024 APPROVED FOR CONSTRUCTION 9 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 5.0 Design Loads - Wind (Cont.): 5.1.2 Global Wind Shear Summary Table: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL-D = Wind Uplift (lbs.) FD = Wind Drag (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Check Calculated Factor of Safety* Check 1.1 3,958 1,213 6,037 333 2,331 2.46 OK 1.2 9,299 3,178 20,144 333 0 2.44 OK 1.3 2,173 784 3,447 333 0 1.75 OK 1.4 2,702 1,127 4,725 333 0 1.84 OK 1.5 3,189 1,393 5,506 333 0 1.78 OK 1.6 3,096 1,178 5,300 333 0 1.86 OK 1.7 2,137 765 3,310 333 0 1.72 OK 1.8 8,706 3,481 20,146 333 0 2.47 OK 1.9 5,485 1,881 10,508 333 0 2.15 OK 1.10 2,062 765 3,250 333 0 1.72 OK 1.11 2,606 981 4,324 333 0 1.81 OK 1.12 1,346 529 2,127 333 0 1.69 OK Total:46,759 lbs.17,275 lbs.88,823  2,331 lbs. Table 5.2 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(((.6)WIND SHEAR/FRICTION)+(.6)WIND UPLIFT) 11/04/2024 APPROVED FOR CONSTRUCTION 10 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 6.0 Design Loads - Downward: 6.1 Downward Wind Load Calculation: WLin = qz * Am * GCP * cos θ Where: qz =17.61 psf (Ref. Section 3.1, Wind Load Data) Am =33.44 sq.ft.(Single Module Area)(Ref. Section 1.1, General Project Information) θ =7.81 deg.(Ref. Section 1.1, General Project Information) GCP =1.13 (Inward)(Proprietary Wind Tunnel Data) GCP =0.30 (Inward with snow)(ASCE, Fig. 30.3-5A) WLin(no snow) = 659 lbs./module WLin(with snow) = 175 lbs./module Contact Base by Location:                                                        Contact Pad by Information: 1 =South Distance Between C.C. outer Pads =12.5 in. 2 =Interior Typical Pad Area =9 sq.in. 3 =2nd from North 4 =North 6.2 Racking Dimensions for Point Loads: Inter-Module Support spacing (S) = 53.23 in. Inter-Column Support Spacing (L) = 41.34 in. Fig. 6.1 Typical Array Plan View (Section A-A) on Next Page 11/04/2024 APPROVED FOR CONSTRUCTION 11 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 6.0 Design Loads - Downward (Cont.): 6.2 Racking Dimensions for Point Loads (Cont.): Fig. 6.2 Section A-A 6.3 Point Load Summary:Notes: DLsys = 103 lbs./module -Base 2 repeat for larger width arrays. Total DL = (Varies on location and ballast quantity) SLm = 0 lbs./module WLin (no snow) = 659 lbs./module WLin (with snow) = 175 lbs./module Max Total Load Per Base (lbs.) load combinations (ASD) Location Base DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) South 1 72 171 91 Interior 2 105 303 145 2nd From North 3 93 291 132 North 4 137 236 157 Table 6.1-A Max Total Load per Base (lbs.) Max Contact Pressure Table Per Base (psi) load combinations (ASD)# of Pads Location Base DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) South 1 4 9 5 Interior 2 6 16 8 2nd From North 3 5 16 7 2 North 4 7 13 9 South 1 2 5 2 Interior 2 3 8 4 2nd From North 3 3 8 4 4 North 4 4 6 4 Table 6.1-B Max Point Load Summary (psi) 11/04/2024 APPROVED FOR CONSTRUCTION 12 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 7.0 Design Loads - Seismic: Seismic Calculations per ASCE 7-16, Chapter 11 - Seismic Design Criteria Chapter 13 - Requirements for Nonstructural Components 7.1 Seismic Load Data: Site Class :D (Ref. Project Information) Seismic Design Category :D (ASCE, Tables 11.6-1 and 11.6-2) Short Period Spectral Resp. (5%) (Ss) :1.303 (Ref. Project Information) 1s Spectral Response (5%) (S1) :0.464 (Ref. Project Information) Bldg. Seismic Imp. Factor (Ie) =1 (ASCE, Table 1.5-2) Adj. MCE Spec. Resp. (Short) (Sms) =Fa*Ss =1.564 (ASCE, Eqn. 11.4-1) Adj. MCE Spec. Resp. (1 sec.) (Sm1) =Fv*S1 =0.852 (ASCE, Eqn. 11.4-2) Short Period Spectral Response (Sds) =2/3(Sms) =1.042 (ASCE, Eqn. 11.4-3) One Second Spectral Response (Sd1) =2/3(Sm1) =0.568 (ASCE, Eqn. 11.4-2) Component Seismic Imp. Factor (Ip) =1 (ASCE, Sec. 13.1.3) Repsonse Modification Factor (Rp) =2.5 (ASCE, Table 13.6-1) Amplification Factor (ap) =1 (ASCE, Table 13.6-1) 7.2 Seismic Design Equations: Lateral Force (Fp) =(ASCE, Eqn. 13.3-1) Lateral Force (FPLmin) =(ASCE, Eqn. 13.3-3) Lateral Force (FPLmax) =(ASCE, Eqn. 13.3-2) Vertical Force (Fpv)) =(ASCE, Eqn. 12.4-4) Lateral Resisting Force (FRL)* =(Factored Load, ASD) Vertical Resisting Force (FRV) =(Factored Load, ASD) * Frictional resistance due to the components weight may be used to resist lateral forces caused by seismic loads. 11/04/2024 APPROVED FOR CONSTRUCTION 13 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 7.0 Design Loads - Seismic (Cont.): 7.3 Lateral Seismic Force Check: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPL = Lateral Seismic Force FRL = Lateral Seismic Resisting Force Array Information Lateral Force Verification Results Sub- Array Name WP (lbs.) FPL (lbs.) FRL (lbs.) 0.7 FPL - FRL (lbs.) MA's Required Total MA Capacity (lbs.) MA's Provided Acceptable 1.1 6,037 3,021 0 2,114 7 2,331 7 Yes 1.2 20,144 10,079 4,546 2,509 0 0 0 Yes 1.3 3,447 1,725 778 429 0 0 0 Yes 1.4 4,725 2,364 1,066 589 0 0 0 Yes 1.5 5,506 2,755 1,242 686 0 0 0 Yes 1.6 5,300 2,652 1,196 660 0 0 0 Yes 1.7 3,310 1,656 747 412 0 0 0 Yes 1.8 20,146 10,080 4,546 2,510 0 0 0 Yes 1.9 10,508 5,258 2,371 1,309 0 0 0 Yes 1.10 3,250 1,626 733 405 0 0 0 Yes 1.11 4,324 2,164 976 539 0 0 0 Yes 1.12 2,127 1,064 480 265 0 0 0 Yes Totals:88,823 lbs 44,443 lbs.18,682 lbs.12,428 lbs.7 2,331 7 Table 7.1 -Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPL-FRL/MA strength 11/04/2024 APPROVED FOR CONSTRUCTION 14 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 7.0 Design Loads - Seismic (Cont.): 7.3.1 Seismic Displacement of Unattached Solar Arrays: Per ASCE 7-16, Section 13.6.12, the use of non-linear response history(NLRH) analysis is permitted to determine the seismic displacement of non-structural components located on the roof. μ =specific to each array, see table 7.3 Roof Pitch :specific to each array, see table 7.3 lp =1 for all arrays le =1 for all arrays PanelClaw, Inc. has engaged the services of a 3rd party consulting engineer to perform NLRH analysis on its clawFR and clawFRplus product. Utilizing that analysis, and the report contained in the Appendix of this package, we are able to determine the displacement of the arrays during seismic events, for the system design life of 25 years. The distance, called Δ MPV, noted below represents the displacement due to the maximum seismic event with a 700 year MRI. The Δ MPV also incorporates the cumulative displacements, over the arrays design life, of smaller seismic events. As a company policy, PanelClaw, Inc., limits the use of this data to Δ MPV displacement of 48" or less. ΔMPV distances are derived from App. B, "Executive Summary: Seismic Displacement Demand of Unattached (ballast-only) Solar Arrays." Using the ΔMPV value above, ASCE 7-16 has adopted the following equations to set the minimum separation between unattached solar arrays and rooftop obstructions. Table 7.3 below lists the required separation. ARRAY CLEARANCES PER ASCE 7 Condition #Condition Description Minimum Separation Equation 1 Between separate solar arrays of similar construction (0.5)(Mpv) 2 Between a solar array and a fixed object on the roof or solar array of different construction (Mpv) 3 Between a solar array and a roof edge with a qualifying parapet (Mpv) 4 Between a solar array and a roof edge without a qualifying parapet (2.0)(Mpv) >= 4 ft NOTE: YOU SHOULD PROVIDE SUFFICIENT SLACK IN ARRAY ELECTRICAL WIRING TO ACCOMMODATE ALL POTENTIAL ARRAY MOVEMENT. 11/04/2024 APPROVED FOR CONSTRUCTION 15 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 7.0 Design Loads - Seismic (Cont.): 7.3.1 Seismic Displacement of Unattached Solar Arrays (Cont.): Sub-Array Information Required Clearances per Condition (in) Min. Provided Clearance per Condition (in) Is Provided Clearance Acceptable (Y/N) Sub-Array Name(s) μ = Slope (deg) ΔMPV (in) 1 2 3 4 1 2 3 4 1 2 3 4 1.2 0.71 2 7 4 7 7 48 121 20 252 252 Y Y Y Y 1.3 0.71 2 7 4 7 7 48 190 22 431 431 Y Y Y Y 1.4 0.71 2 7 4 7 7 48 62 28 506 506 Y Y Y Y 1.5 0.71 2 7 4 7 7 48 62 162 260 260 Y Y Y Y 1.6 0.71 2 7 4 7 7 48 190 27 411 411 Y Y Y Y 1.7 0.71 2 7 4 7 7 48 185 23 814 814 Y Y Y Y 1.8 0.71 2 7 4 7 7 48 153 18 251 251 Y Y Y Y 1.9 0.71 2 7 4 7 7 48 121 26 1,008 1,008 Y Y Y Y 1.10 0.71 2 7 4 7 7 48 179 24 810 810 Y Y Y Y 1.11 0.71 2 7 4 7 7 48 129 22 256 256 Y Y Y Y 1.12 0.71 2 7 4 7 7 48 153 19 819 819 Y Y Y Y Table 7.3 - Sub-Array predicted movement, required clearances, provided clearances, and acceptance 11/04/2024 APPROVED FOR CONSTRUCTION 16 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 7.0 Design Loads - Seismic (Cont.): 7.4 Vertical Seismic Force Check: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPV = Vertical Seismic Force FRV = Vertical Seismic Resisting Force Array Information Vertical Force Verification Results Sub- Array Name WP (lbs.) FPV (lbs.) FRV (lbs.) 0.7 FPV - FRV (lbs.) MA's Required Total MA Capacity (lbs.) Total MA's Provided Acceptable 1.1 6,037 1,259 3,622 -2,741 0 2,276 7 Yes 1.2 20,144 4,200 12,086 -9,146 0 0 0 Yes 1.3 3,447 719 2,068 -1,565 0 0 0 Yes 1.4 4,725 985 2,835 -2,145 0 0 0 Yes 1.5 5,506 1,148 3,303 -2,500 0 0 0 Yes 1.6 5,300 1,105 3,180 -2,406 0 0 0 Yes 1.7 3,310 690 1,986 -1,503 0 0 0 Yes 1.8 20,146 4,200 12,087 -9,147 0 0 0 Yes 1.9 10,508 2,191 6,305 -4,771 0 0 0 Yes 1.10 3,250 678 1,950 -1,476 0 0 0 Yes 1.11 4,324 901 2,594 -1,963 0 0 0 Yes 1.12 2,127 443 1,276 -966 0 0 0 Yes Total:88,823 lbs.18,518 lbs.53,294 lbs.-40,331 lbs.0 2,276 7 Table7.2 - Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPV - FRV/MA strength 11/04/2024 APPROVED FOR CONSTRUCTION 17 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A Appendix A 18 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A 19 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A 20 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A 21 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A 22 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A 23 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix A 24 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B Appendix B25 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B26 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B27 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B28 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B29 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B30 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Appendix B31 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1330 E Seventeenth St4/10/2025 Presented by: Structural Analysis of Building for a Proposed Rooftop Solar PV System N Grand Ave & 17th St, Santa Ana, CA 92705 Target T0286 - Santa Ana For The Project: Presented to: 805 Third Avenue, 14th Floor New York, NY 10022 Rev. 0 Pure Power Engineering, Inc. 111 River Street - Suite 1110 Hoboken, NJ 07030 www.PurePower.com (201)687-9975 July 19, 2024 Ying Liu, PE Patrick Bair, PE PPE Project No. PPE-05184.03 Ahmed Youssef, PE 1330 E Seventeenth St4/10/2025 Table of Contents Executive Summary Reserved Load/Girder Location Plan(s) Standard Conditions for Engineering Services on Existing Structures Codes and Design Criteria Analysis Assumptions Conclusion Appendix A - Calculations Appendix B - Existing Plans Appendix C - Racking Plans Target T0286 - Santa Ana - Final Report PPE-05184.03 Table of Contents Checked by AY Prepared by PB 7/19/2024 1.1 3.1 - 3.2 4.1 5.1 6.1 2.1 - 2.2 1330 E Seventeenth St4/10/2025 Executive Summary • Existing building is feasible for PV solar system. • Reserved capacity and maximum allowable deck loads for the existing roof: Reserved Capacity = Maximum system weight = Deck Downward = (controlled by 2x4 purlin for point load spaced at 4.0 ft o.c.) Assuming using U-Anchor 2400/2600 with 8-#14 fasteners and w/ PanelClaw racking system with U-bracket Uplift = Shear = 0 (in a 2.0' wide strip X 6.5' long spans, point loads spaced at 3.0' and 3.7' o.c.) Assuming using OMG PowerGrip Plus with 8-#14 fasteners and w/ PanelClaw racking system with U-bracket Uplift = Shear = 0 Assuming using Facet with 8-#14 fasteners and w/ PanelClaw racking system with U-bracket Uplift = Shear = Notes: Existing Structure Target T0286 - Santa Ana - Final Report The original structure is Target T0286 - Santa Ana building located at N Grand Ave & 17th St, Santa Ana, CA 92705. The referenced building is a one story wood frame structure, which was built circa 1966. The approximate total area is 107370 square feet. Typical roof construction consists of 1/2 Plywood Deck (assumed) supported by wood joists spaced at 1'-4" o.c., supported by wood purlins spaced at 8'-0" o.c. Purlins are supported by girders spaced at 30' o.c. 350.0 lb 335 lb 200 lb PPE-05184.03 7/19/2024 A (PV) Solar Array is proposed to be installed with modules mounted to a ballasted (and/or mechanically attached) racking system and supported on the rooftop of the subject building. Pure Power has performed a structural analysis and determined the following: 320.0 lb Sheet 1.1 Prepared by PB 315 lb 224,084 lb Checked by AY 6.0 psf • The allowable deck loads will be dependent on the racking system used. At the time of the writing of this report, this information was not available. The allowable deck loads are subject to change upon receiving this information. •PPE has reviewed the racking package produced by PanelClaw dated 07/06/2024 and verified conformance to the structural loading limitations presented in this report. All allowable capacities listed above are based on min. 0.5" penertration in existing plywood sheathing. 450 lb 200 lb 333 lb 1330 E Seventeenth St4/10/2025 Reserved Load Plan Target T0286 - Santa Ana - Final Report 7/19/2024 Sheet 2.1 Prepared by PB PPE-05184.03 Checked by AY (Blue Shaded Area) Reserved Capacity = 6 psf No PV in the Red Shaded Areas 1330 E Seventeenth St4/10/2025 Girder Location Plan Target T0286 - Santa Ana - Final Report 7/19/2024 PPE-05184.03 Sheet 2.2 Prepared by PB Checked by AY Red lines indicate girder locations. Locate new rooftop equipment over exisiting girder locations shown below. Verify in Field exact locations of existing girders. 1330 E Seventeenth St4/10/2025 Standard Conditions for Engineering Services on Existing Structures Proposed PV-Panels and Preliminary Design Target T0286 - Santa Ana - Final Report 7/19/2024 Sheet 3.1 Prepared by PB Checked by AY • PV solar panels shall be installed on the roof as arrays on a ballasted racking system. A typical ballasted racking system is designed to resist wind uplift and sliding by placing concrete blocks (ballast) as counterweight on the racks. The system does not increase uplift on the building because the ballast should be designed to resist the additional uplift in order to provide the code required factor of safety. • If the PV racking system is mechanically attached to the roof deck, then the uplift and shear forces at each mechanical attachment are not to exceed the capacity noted in this report under the conclusion section. • It is assumed that the panels will be approximately 12 inches above the rooftop at the high end. • It is assumed that the average design weight includes the weight of the panels, racking system and the ballast and all required assemblies. PPE-05184.03 • The analysis is based on the information gathered from the field and/or information provided to Pure Power Engineering and is assumed to be current and accurate. • Unless noted otherwise, the structure and the foundation system are assumed to be in good condition, free of defects, and can achieve theoretical strength. • It is assumed that the structure has been properly maintained and shall be properly maintained during its service. The superstructure and the foundation system are assumed to be designed with proper engineering practice and fabricated, constructed and erected in accordance with the design documents. Pure Power will accept no liability which may arise due to any existing deficiency in design, material, fabrication, erection, construction, etc. or lack of maintenance. • The analysis results are only applicable for the proposed additions and alterations specified in this report. Any deviation of the proposed equipment and placement, etc., will require Pure Power to generate an additional structural analysis. • The analysis does not include the design of the racking system or the ballast it requires. The analysis is performed to verify the capacity of the main structural system. Connections are assumed to have the capacity of the main structural members. • Pure Power assumes that the existing building has NOT been modified or altered from its original design. Building landlord/client shall inform PPE with any kind of modification and/or alteration that may have been done to the existing building during its lifetime. 1330 E Seventeenth St4/10/2025 Existing Building Code Allowance Target T0286 - Santa Ana - Final Report PPE-05184.03 Checked by AY • Pursuant to CA Existing Building Code section 502.4, any existing gravity load-carrying structural element for which additions and/or alterations cause an increase in design gravity load of no more than 5 percent, shall be permitted to remain unaltered, thus considered to be code-compliant and adequate. Any existing gravity load- carrying structural element for which additions and/or alterations cause an increase in design gravity loads exceeding 5 percent is checked against the applicable Code criteria for new structures. • Pursuant to CA Existing Building Code Sections 502.5, any existing lateral load-carrying structural element whose demand-capacity ratio with the addition and/or alteration considered is no more than 10 percent greater than its demand-capacity ratio with the addition and/or alteration ignored shall be permitted to remain unaltered, thus considered to be Code-compliant and adequate. If the demand- capacity ratio increase is more than 10 percent, the subject structural element is checked against the applicable Code criteria for new structures. • Pursuant International Building Code section 1607A.13.5.1, where PV panels are installed on building roof, it is not necessary to include roof live load in the area(s) covered by the panels when these area(s) are inaccessible, or signs are posted prohibiting storage under the panels. Therefore, Pure Power has applied the roof live/snow load in all areas that are still accessible and subject to foot traffic, maintenance workers, storage, etc., but not directly under the modules. Sheet 3.2 7/19/2024 Prepared by PB 1330 E Seventeenth St4/10/2025 Codes and References 2022 California Building Code, Adopting 2021 International Building Code with Amendments Minimum Design Loads for Buildings and Other Structures, ASCE 7-16 2018 National Design Specification, NDS, by the American Wood Council Design Criteria Snow Load (Service) Ground Snow Load: Risk Category: Snow Exposure: Ce: Snow Load Important Factor Is: Thermal Factor Ct: Flat Snow Load: Roof Live Load (Service) Wind Load Risk Category: Ultimate Wind Speed: Exposure Category: Seismic Load Risk Category: Ie, Seismic Importance Factor: Site Class: SS, Mapped spectral response acceleration at short periods: SDS, Design spectral response acceleration at short periods: S1, Mapped spectral response acceleration at 1s period: SD1, Design spectral response acceleration at 1s period: Seismic Design Category: Target T0286 - Santa Ana - Final Report Checked by AY 7/19/2024 Sheet 4.1 Prepared by PB 0 psf II 1.0 II 1.255 0.664 0.575 94 mph 1.0 1.0 20.0 psf II 1.00 C 1.882 0.0 psf B Note: The racking manufacturer/the racking manufacturer’s structural engineer shall be responsible to verify the design criteria when designing the racking system. PPE-05184.03 D 1330 E Seventeenth St4/10/2025 Analysis Assumptions for Existing Roof The proposed PV system is to weigh a maximum Therefore, the proposed loading, including the weight of the PV system is as follows: Roofing & Insulation Plywood Sheathing Wood Framing MEP, Sprinklers & Ceiling Total Roof DL = PV System Weight Roof SL = Total Roof Load = Target T0286 - Santa Ana - Final Report Sheet 5.1 Prepared by PB The building was analyzed based on the construction drawings by John E Mackel and Associates - Consulting Structural Engineers dated 02/25/1966. 5.0 psf 7/19/2024 Checked by AY PPE performed structural analysis for the roof elements. It was found that the weight of the proposed solar array with ballasts plus the design roof dead load did not exceed the members capacity. Therefore, the structure may remain unaltered. PPE-05184.03 13.5 psf 6.0 psf 0.0 psf 19.5 psf 2.0 psf 1.5 psf 5.0 psf PPE understands that the area where the clear space between the panels and rooftop is not more than 24 in. Therefore, as per the current state code (section 1607A.13.5.1), roof live load does NOT need to be considered on areas where the proposed PV system will be installed. 6.0 psf 1330 E Seventeenth St4/10/2025 Conclusion Sincerely, Ying Liu, PE Ahmed Youssef, PE Patrick Bair, PE Target T0286 - Santa Ana - Final Report 7/19/2024 Sheet 6.1 Prepared by PB Based on our experience and engineering analysis of the information available at the time of this writing, it is the opinion of this organization that the added stresses due to the weight of the proposed PV modules are considered acceptable and will not exceed the capacity of the existing roof structure. The proposed PV modules may be installed at Target T0286 - Santa Ana under the conditions outlined in the body of this report. Do not stage pallets on roof unless staging plan drawing is provided by PPE. This report does not represent an approval of the proposed PV system design. It is the racking designer’s responsibility to ensure any proposed racking system is within the limits stated in this report and their system is designed in accordance with the requirements in the governing building code. PPE can review the existing framing adequacy for anchorage reaction loads upon request and if the racking design are supplied to PPE by the racking designer. PPE-05184.03 Checked by AY 1330 E Seventeenth St4/10/2025 APPENDIX A CALCULATIONS 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.1 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 A. Gravity Loads A.1. Snow Loads SL = 0 psf A.2. Load Combinations (ASD) The weight of the proposed PV system shall be considered a dead load Dead Load, DL = 13.5 psf Solar Load, PV = 6 psf (considered as DL) Live Load, LL = 0 psf (concurrent with solar) Snow Load, SL = 0 psf LC1: DL = 13.5 psf LC2: DL + PV + SL = 19.5 psf LC3: DL + LL = 13.5 psf Therefore, LC2 governs. 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.2 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 A.3. Sub-Purlins A.3.1. 2x4 @ 16” o.c. Span: 8’-0” Joist Spacing: 1’-4” Proposed Load: 19.5 psf – 5 psf (wood framing) = 14.5 psf * 1.33’ = 19.28 plf Sub-purlin self-weight account for in the software In accordance with the ANSI/AF&PA NDS-2018 using the LRFD method Tedds calculation version 1.7.10 Applied loading Beam loads Dead self weight of beam ´ 1 Dead full UDL 19 lb/ft Load combinations 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.3 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Load combination 1 Support A Dead ´ 1.40 Live ´ 0.00 Span 1 Dead ´ 1.40 Live ´ 0.00 Support B Dead ´ 1.40 Live ´ 0.00 Analysis results Maximum moment;Mmax = 213 lb_ft; Mmin = 0 lb_ft Design moment; M = max(abs(Mmax),abs(Mmin)) = 213 lb_ft Maximum shear; Fmax = 111 lb; Fmin = -111 lb Design shear; F = max(abs(Fmax),abs(Fmin)) = 111 lb Total load on member; Wtot = 222 lb Reaction at support A; RA_max = 111 lb; RA_min = 111 lb Unfactored dead load reaction at support A; RA_Dead = 79 lb Reaction at support B; RB_max = 111 lb; RB_min = 111 lb Unfactored dead load reaction at support B; RB_Dead = 79 lb Sawn lumber section details Nominal breadth of sections; bnom = 2 in Dressed breadth of sections; b = 1.5 in Nominal depth of sections; dnom = 4 in Dressed depth of sections; d = 3.5 in Number of sections in member; N = 1 Overall breadth of member; bb = N ´ b = 1.5 in Species, grade and size classification; Douglas Fir-Larch, No.1 grade, 2'' & wider Bending parallel to grain; F b = 1000 lb/in 2 Tension parallel to grain; Ft = 675 lb/in2 Compression parallel to grain; Fc = 1500 lb/in2 Compression perpendicular to grain; Fc_perp = 625 lb/in2 Shear parallel to grain; F v = 180 lb/in 2 Modulus of elasticity; E = 1700000 lb/in2 Modulus of elasticity, stability calculations; Emin = 620000 lb/in2 Mean shear modulus; Gdef = E / 16 = 106250 lb/in2 Member details Service condition; Dry Length of span; Ls1 = 7.7 ft Length of bearing; Lb = 1 in The beam is one of three or more repetitive members Section properties Cross sectional area of member; A = N ´ b ´ d = 5.25 in2 Section modulus; Sx = N ´ b ´ d2 / 6 = 3.06 in3 Sy = d ´ (N ´ b)2 / 6 = 1.31 in3 Second moment of area; Ix = N ´ b ´ d3 / 12 = 5.36 in4 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.4 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 I y = d ´ (N ´ b)3 / 12 = 0.98 in 4 Adjustment factors Resistance factor for bending - Table 2.3.6; fb = 0.85 Resistance factor for tension - Table 2.3.6; ft = 0.80 Resistance factor for compression - Table 2.3.6; fc = 0.90 Resistance factor for shear - Table 2.3.6; fv = 0.75 Resistance factor for modulus of elasticity - Table 2.3.6 fs = 0.85 Format conversion factor for bending -Table 2.3.5; KFb = 2.54 Format conversion factor for tension -Table 2.3.5; KFt = 2.70 Format conversion factor for compression - Table 2.3.5 KFc = 2.40 Format conversion factor for shear -Table 2.3.5; KFv = 2.88 Format conversion factor for perp.compression - Table 2.3.5 KFc_perp = 1.67 Format conversion factor for modulus of elasticity - Table 2.3.5 KFE = 1.76 Time effect factor - Table N.3; l = 0.60 Temperature factor - Table 2.3.3; Ct = 1.00 Size factor for bending - Table 4A; CFb = 1.50 Size factor for tension - Table 4A; CFt = 1.50 Size factor for compression - Table 4A; CFc = 1.15 Flat use factor - Table 4A; Cfu = 1.10 Incising factor for modulus of elasticity - Table 4.3.8 CiE = 1.00 Incising factor for bending, shear, tension & compression - Table 4.3.8 Ci = 1.00 Incising factor for perpendicular compression - Table 4.3.8 Cic_perp = 1.00 Repetitive member factor - cl.4.3.9; Cr = 1.15 Bearing area factor - cl.3.10.4; Cb = 1.00 Depth-to-breadth ratio; dnom / (N ´ bnom) = 2.00 - Beam is fully restrained Beam stability factor - cl.3.3.3; CL = 1.00 Bearing perpendicular to grain - cl.3.10.2 Design compression perpendicular to grain; Fc_perp' = Fc_perp ´ KFc_perp ´ fc ´ Ct ´ Cic_perp ´ Cb = 939 lb/in2 Applied compression stress perpendicular to grain; fc_perp = RA_max / (N ´ b ´ Lb) = 74 lb/in2 fc_perp / Fc_perp' = 0.079 PASS - Design compressive stress exceeds applied compressive stress at bearing Strength in bending - cl.3.3.1 Design bending stress; F b' = Fb ´ KFb ´ fb ´ l ´ Ct ´ CL ´ CFb ´ Ci ´ Cr = 2235 lb/in 2 Actual bending stress; f b = M / Sx = 836 lb/in 2 fb / Fb' = 0.374 PASS - Design bending stress exceeds actual bending stress Strength in shear parallel to grain - cl.3.4.1 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.5 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Design shear stress; F v' = Fv ´ KFv ´ fv ´ l ´ Ct ´ Ci = 233 lb/in 2 Actual shear stress - eq.3.4-2; fv = 3 ´ F / (2 ´ A) = 32 lb/in2 fv / Fv' = 0.136 PASS - Design shear stress exceeds actual shear stress Deflection - cl.3.5.1 Modulus of elasticity for deflection; E' = E ´ C ME ´ Ct ´ CiE = 1700000 lb/in 2 Design deflection; dadm = 0.0083 ´ Ls1 = 0.767 in Total deflection; db_s1 = 0.178 in db_s1 / dadm = 0.233 PASS - Total deflection is less than design deflection Utilization: = 37.4 % ≤ 105% ⇒ OK A.4. Purlins A.4.1. 6x16 @ 16” o.c. Span: 30’-0” (29.4 ft end to end) Joist Spacing: 8’-0” Proposed Loads are reactions from sub-purlin applied as point load to purlin: DL from sub-purlin = 0.079k x 2 = 0.158k @ 1.33 ft o.c. Purlin self-weight account for in the software In accordance with the ANSI/AF&PA NDS-2018 using the LRFD method Tedds calculation version 1.7.10 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.6 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Applied loading Beam loads Dead self weight of beam ´ 1 Dead point load 158 lb at 15.96 in Dead point load 158 lb at 31.92 in Dead point load 158 lb at 47.88 in Dead point load 158 lb at 63.84 in Dead point load 158 lb at 79.80 in Dead point load 158 lb at 95.76 in Dead point load 158 lb at 111.72 in Dead point load 158 lb at 127.68 in Dead point load 158 lb at 143.64 in Dead point load 158 lb at 159.60 in Dead point load 158 lb at 175.56 in Dead point load 158 lb at 191.52 in Dead point load 158 lb at 207.48 in Dead point load 158 lb at 223.44 in Dead point load 158 lb at 239.40 in Dead point load 158 lb at 255.36 in Dead point load 158 lb at 271.32 in Dead point load 158 lb at 287.28 in Dead point load 158 lb at 303.24 in Span 1 loads Dead point load 158 lb at 319.20 in Dead point load 158 lb at 335.16 in Dead point load 158 lb at 352.80 in Dead point load 158 lb at 0.00 in Load combinations Load combination 1 Support A Dead ´ 1.40 Live ´ 0.00 Span 1 Dead ´ 1.40 Live ´ 0.00 Support B Dead ´ 1.40 Live ´ 0.00 Analysis results Maximum moment;Mmax = 21095 lb_ft; Mmin = 0 lb_ft Design moment; M = max(abs(Mmax),abs(Mmin)) = 21095 lb_ft Maximum shear; Fmax = 2981 lb; Fmin = -2959 lb 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.7 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Design shear; F = max(abs(Fmax),abs(Fmin)) = 2981 lb Total load on member; Wtot = 5940 lb Reaction at support A; RA_max = 2981 lb; RA_min = 2981 lb Unfactored dead load reaction at support A; RA_Dead = 2129 lb Reaction at support B; RB_max = 2959 lb; RB_min = 2959 lb Unfactored dead load reaction at support B; RB_Dead = 2114 lb Sawn lumber section details Nominal breadth of sections; bnom = 6 in Dressed breadth of sections; b = 5.5 in Nominal depth of sections; dnom = 16 in Dressed depth of sections; d = 15.5 in Number of sections in member; N = 1 Overall breadth of member; bb = N ´ b = 5.5 in Species, grade and size classification; Douglas Fir-Larch, No.1 grade, Beams and stringers Bending parallel to grain; Fb = 1350 lb/in2 Tension parallel to grain; F t = 675 lb/in 2 Compression parallel to grain; Fc = 925 lb/in2 Compression perpendicular to grain; Fc_perp = 625 lb/in2 Shear parallel to grain; F v = 170 lb/in 2 Modulus of elasticity; E = 1600000 lb/in2 Modulus of elasticity, stability calculations; Emin = 580000 lb/in2 Mean shear modulus; G def = E / 16 = 100000 lb/in 2 Member details Service condition; Dry Length of span; Ls1 = 29.4 ft Length of bearing; Lb = 2 in Section properties Cross sectional area of member; A = N ´ b ´ d = 85.25 in2 Section modulus; Sx = N ´ b ´ d2 / 6 = 220.23 in3 Sy = d ´ (N ´ b)2 / 6 = 78.15 in3 Second moment of area; Ix = N ´ b ´ d3 / 12 = 1706.78 in4 Iy = d ´ (N ´ b)3 / 12 = 214.90 in4 Adjustment factors Resistance factor for bending - Table 2.3.6; fb = 0.85 Resistance factor for tension - Table 2.3.6; ft = 0.80 Resistance factor for compression - Table 2.3.6; fc = 0.90 Resistance factor for shear - Table 2.3.6; fv = 0.75 Resistance factor for modulus of elasticity - Table 2.3.6 fs = 0.85 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.8 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Format conversion factor for bending -Table 2.3.5; KFb = 2.54 Format conversion factor for tension -Table 2.3.5; KFt = 2.70 Format conversion factor for compression - Table 2.3.5 KFc = 2.40 Format conversion factor for shear -Table 2.3.5; KFv = 2.88 Format conversion factor for perp.compression - Table 2.3.5 KFc_perp = 1.67 Format conversion factor for modulus of elasticity - Table 2.3.5 KFE = 1.76 Time effect factor - Table N.3; l = 0.60 Temperature factor - Table 2.3.3; Ct = 1.00 Size factor for bending - Table 4D; CFb = 0.97 Size factor for tension - Table 4D; CFt = 1.00 Size factor for compression - Table 4D; CFc = 1.00 Flat use factor - Table 4D; Cfu = 1.00 Incising factor for modulus of elasticity - Table 4.3.8 CiE = 1.00 Incising factor for bending, shear, tension & compression - Table 4.3.8 Ci = 1.00 Incising factor for perpendicular compression - Table 4.3.8 Cic_perp = 1.00 Repetitive member factor - cl.4.3.9; Cr = 1.00 Bearing area factor - cl.3.10.4; Cb = 1.00 Depth-to-breadth ratio; dnom / (N ´ bnom) = 2.67 Effective laterally unsupported span length; le = 1.33 ft Slenderness ratio for bending members - eq.3.3-5; R b = Ö[le ´ d / (N ´ b) 2] = 2.860 Adjusted bending design value for bending; F b * = Fb ´ KFb ´ fb ´ l ´ CMb ´ Ct ´ CFb ´ Ci ´ Cr = 1700 lb/in2 Adjusted modulus of elasticity for member stability; Emin' = Emin ´ CME ´ Ct ´ CiE ´ KFE ´ fs = 867680 lb/in2 Critical buckling design value for bending; F bE = 1.2 ´ Emin' / Rb 2 = 127321 lb/in 2 Beam stability factor - eq.3.3-6 C L = [1 + (FbE / Fb * )] / 1.9 - Ö[([1 + (FbE / Fb *)] / 1.9)2 - (FbE / Fb*) / 0.95] = 1.00 Bearing perpendicular to grain - cl.3.10.2 Design compression perpendicular to grain; Fc_perp' = Fc_perp ´ KFc_perp ´ fc ´ Ct ´ Cic_perp ´ Cb = 939 lb/in2 Applied compression stress perpendicular to grain; f c_perp = RA_max / (N ´ b ´ Lb) = 271 lb/in 2 fc_perp / Fc_perp' = 0.289 PASS - Design compressive stress exceeds applied compressive stress at bearing Strength in bending - cl.3.3.1 Design bending stress; F b' = Fb ´ KFb ´ fb ´ l ´ Ct ´ C L ´ CFb ´ Ci ´ Cr = 1699 lb/in 2 Actual bending stress; fb = M / Sx = 1149 lb/in2 fb / Fb' = 0.677 PASS - Design bending stress exceeds actual bending stress Strength in shear parallel to grain - cl.3.4.1 Design shear stress; Fv' = Fv ´ K Fv ´ f v ´ l ´ C t ´ Ci = 220 lb/in 2 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.9 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Actual shear stress - eq.3.4-2; f v = 3 ´ F / (2 ´ A) = 52 lb/in 2 fv / Fv' = 0.238 PASS - Design shear stress exceeds actual shear stress Deflection - cl.3.5.1 Modulus of elasticity for deflection; E' = E ´ CME ´ Ct ´ C iE = 1600000 lb/in2 Design deflection; dadm = 0.0083 ´ Ls1 = 2.928 in Total deflection; db_s1 = 0.857 in db_s1 / dadm = 0.293 PASS - Total deflection is less than design deflection Utilization: = 67.7 % ≤ 105% ⇒ OK A.5. Girders A.5.1. G1 - 7 x 38 7/8 (controlling girder) Span: 77’-6” Purlin Spacing: 8’-0” Proposed Loads are reactions from purlin applied as point load to girder: DL from Purlin = 2.129k x 2 = 4.258k @ 8 ft o.c. Girder self-weight accounted for in the software In accordance with the ANSI/AF&PA NDS-2018 using the LRFD method Tedds calculation version 1.7.10 Applied loading Beam loads Dead self weight of beam ´ 1 Span 1 loads Dead point load 4258 lb at 96.00 in Dead point load 4258 lb at 192.00 in Dead point load 4258 lb at 288.00 in Dead point load 4258 lb at 384.00 in Dead point load 4258 lb at 480.00 in Dead point load 4258 lb at 576.00 in Dead point load 4258 lb at 672.00 in Dead point load 4258 lb at 768.00 in 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.10 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Span 2 loads Dead point load 4258 lb at 78.00 in Dead point load 10765 lb at 144.00 in Load combinations Load combination 1 Support A Dead ´ 1.40 Live ´ 0.00 Span 1 Dead ´ 1.40 Live ´ 0.00 Support B Dead ´ 1.40 Live ´ 0.00 Span 2 Dead ´ 1.20 Live ´ 1.60 Support C Dead ´ 1.20 Live ´ 1.60 Analysis results Maximum moment;Mmax = 348135 lb_ft; Mmin = -193943 lb_ft Design moment; M = max(abs(Mmax),abs(Mmin)) = 348135 lb_ft Maximum shear; Fmax = 21303 lb; Fmin = -32406 lb Design shear; F = max(abs(Fmax),abs(Fmin)) = 32406 lb Total load on member; Wtot = 72689 lb Reaction at support A; RA_max = 21303 lb; RA_min = 21303 lb Unfactored dead load reaction at support A; RA_Dead = 14861 lb Reaction at support B; RB_max = 51386 lb; RB_min = 51386 lb Unfactored dead load reaction at support B; RB_Dead = 39319 lb Reaction at support C; RC_max = 0 lb; RC_min = 0 lb Unfactored dead load reaction at support C; RC_Dead = 0 lb Glulam section details Net finished breadth of sections; b = 7 in Net finished depth of sections; d = 38.875 in Number of sections in member; N = 1 Overall breadth of member; bb = N ´ b = 7 in Alignment of laminations; Horizontal Stress class; 24F-V8 DF/DF Tension parallel to grain; Ft = 1100 lb/in2 Compression parallel to grain; Fc = 1650 lb/in2 Bending about X-X axis properties (loaded perpendicular to wide faces of laminations): Positive bending; Fbx_pos = 2400 lb/in2 Negative bending; Fbx_neg = 2400 lb/in2 Compression perpendicular to grain; Fc_perp = 650 lb/in2 Shear parallel to grain; Fv = 265 lb/in2 Modulus of elasticity; E = 1800000 lb/in2 Modulus of elasticity, stability calculations; Emin = 950000 lb/in2 Mean shear modulus; Gdef = E / 16 = 112500 lb/in2 Bending about Y-Y axis properties (loaded parallel to wide faces of laminations): Bending; Fby = 1550 lb/in2 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.11 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Modulus of elasticity; stability calculations; Eymin = 850000 lb/in2 Member details Service condition; Dry Length of span 1; Ls1 = 65 ft Length of span 2; Ls2 = 12 ft Length of bearing; Lb = 12 in The beam is one of three or more repetitive members Section properties Cross sectional area of member; A = N ´ b ´ d = 272.13 in2 Section modulus; Sx = N ´ b ´ d2 / 6 = 1763.14 in3 Sy = d ´ (N ´ b)2 / 6 = 317.48 in3 Second moment of area; Ix = N ´ b ´ d3 / 12 = 34271.10 in4 Iy = d ´ (N ´ b)3 / 12 = 1111.18 in4 Adjustment factors Resistance factor for bending - Table 2.3.6; fb = 0.85 Resistance factor for tension - Table 2.3.6; ft = 0.80 Resistance factor for compression - Table 2.3.6; fc = 0.90 Resistance factor for shear - Table 2.3.6; fv = 0.75 Resistance factor for modulus of elasticity - Table 2.3.6 fs = 0.85 Format conversion factor for bending -Table 2.3.5; KFb = 2.54 Format conversion factor for tension -Table 2.3.5; KFt = 2.70 Format conversion factor for compression - Table 2.3.5 KFc = 2.40 Format conversion factor for shear -Table 2.3.5; KFv = 2.88 Format conversion factor for perp.compression - Table 2.3.5 KFc_perp = 1.67 Format conversion factor for modulus of elasticity - Table 2.3.5 KFE = 1.76 Time effect factor - Table N.3; l = 0.60 Temperature factor - Table 2.3.3; Ct = 1.00 Flat use factor - Table 5A; Cfu = 1.04 Bearing area factor - cl.3.10.4; Cb = 1.00 Length of beam between points of zero moment; L0 = 55 ft For species other than Southern Pine; x = 10 Volume factor - eq.5.3-1; CV = min((21 ft / L0)1/x ´ (12 in / d)1/x ´ (5.125 in / b)1/x, 1) = 0.78 Depth-to-breadth ratio; d / (N ´ b) = 5.55 Effective laterally unsupported span length; le = 8 ft Slenderness ratio for bending members - eq.3.3-5; Rb = Ö[le ´ d / (N ´ b)2] = 8.727 Adjusted bending design value for bending; Fb* = Fbx_pos ´ KFb ´ fb ´ l ´ CMb ´ Ct ´ Cc = 3109 lb/in2 Adjusted modulus of elasticity for member stability; Eymin' = Eymin ´ CME ´ Ct ´ KFE ´ fs = 1271600 lb/in2 Critical buckling design value for bending; FbE = 1.2 ´ Eymin' / Rb2 = 20035 lb/in2 Beam stability factor - eq.3.3-6 CL = [1 + (FbE / Fb*)] / 1.9 - Ö[([1 + (FbE / Fb*)] / 1.9)2 - (FbE / Fb*) / 0.95] = 0.99 Bearing perpendicular to grain - cl.3.10.2 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.12 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 Design compression perpendicular to grain; Fc_perp' = Fc_perp ´ KFc_perp ´ fc ´ Ct ´ Cb = 977 lb/in2 Applied compression stress perpendicular to grain; fc_perp = RB_max / (N ´ b ´ Lb) = 612 lb/in2 fc_perp / Fc_perp' = 0.626 PASS - Design compressive stress exceeds applied compressive stress at bearing Strength in bending - cl.3.3.1 Design bending stress; Fb' = Fbx_pos ´ KFb ´ fb ´ l ´ Ct ´ min(CL, CV) ´ Cc = 2433 lb/in2 Actual bending stress; fb = Mmax / Sx = 2369 lb/in2 fb / Fb' = 0.974 PASS - Design bending stress exceeds actual bending stress Strength in shear parallel to grain - cl.3.4.1 Design shear stress; Fv' = Fv ´ KFv ´ fv ´ l ´ Ct = 343 lb/in2 Actual shear stress - eq.3.4-2; fv = 3 ´ F / (2 ´ A) = 179 lb/in2 fv / Fv' = 0.520 PASS - Design shear stress exceeds actual shear stress Deflection - cl.3.5.1 Modulus of elasticity for deflection; E' = Ex ´ CME ´ Ct = 1800000 lb/in2 Design deflection; dadm = 0.0083 ´ 2 ´ Ls2 = 2.390 in Total deflection; db_s2 = -0.904 in db_s2 / dadm = -0.378 PASS - Total deflection is less than design deflection Utilization: = 97.4% ≤ 105% ⇒ OK 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.13 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 B. Lateral Loads As per the existing building code, the lateral load resistance system shall be permitted to remain unaltered if the stresses are increased by 10% or less. Roof diaphragm is one of the lateral load-carrying members and the reserved capacity will be governed by its capacity. Total roof area = 107,370 ft2 Assumed Original Dead Load = 15 psf DL = 15 psf x 107,370 ft2 = 1610.550 kips Wall weight = 2 x ½ x 289 ft x 28.67 ft x 94 psf (12” CMU) = 630.2884kip Roof Diaphragm Original Total Mass Dead Loads; Wpx-Orig. = 2,240.84 kip = 20.87psf PV-System Max. Weight = 10% x 20.87 psf = 2.1 psf PV-System Max. Weight = 2.1psf x 107,370 ft2 = 224,084 lbs PV-System Max. Weight = 224,084 lbs 1330 E Seventeenth St4/10/2025 7/19/2024 Sheet A.14 Prepared by PB Checked by AY Target T0286- Santa Ana – Final Report PPE-05184.03 C. Roof Deck 1 ½” plywood roof deck Span = 1’-4” Max load = 3.5 psf roofing, insulation, and deck + 6+ psf solar = 9.5 psf Plywood capacity = 91 psf/2.5 factor of safety = 36.4 psf Allowable Load = 36.4 psf Utilization = 9.5 / 36.4 = 26.1% ⇒ OK 1330 E Seventeenth St4/10/2025 APPENDIX B EXISTING DRAWINGS 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 1330 E Seventeenth St4/10/2025 APPENDIX C RACKING DRAWINGS 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SETRACKING CONSTRUCTION SET GENERAL NOTES: 1. ALL SITE, PROJECT, AND BUILDING DETAILS ARE PROVIDED BY CUSTOMER OR GENERATED VIA SATELLITE IMAGERY FROM INFORMATION PROVIDED BY CUSTOMER. PANELCLAW IS NOT RESPONSIBLE FOR SITE INACCURACIES THAT COULD LEAD TO CHANGES TO THESE DRAWING DETAILS AND ARRAY LAYOUT CONFIGURATIONS. ALL INFORMATION CONTAINED WITHIN THESE DOCUMENTS ARE TO BE FIELD VERIFIED BY CUSTOMER AND INSTALLER. ANY CHANGES OR MODIFICATIONS TO THESE DOCUMENTS, CONTAINED INFORMATION, OR FINAL ARRAY AND MOUNTING SYSTEM INSTALLATIONS MUST BE SUBMITTED TO PANELCLAW AND OTHER PROJECT AUTHORITIES FOR APPROVAL. 2. REFER TO AND FOLLOW THE APPROPRIATE PANELCLAW INSTALLATION MANUALS AND PROCEDURES DURING THE INSTALLATION PROCESS. NOT FOLLOWING SUCH PROCEDURES AND METHODS COULD RESULT IN DAMAGE TO THE COMPONENTS OR MAY VOID THE PRODUCT WARRANTY. 3. ARRAY SETBACKS: ALL ARRAYS ARE REQUIRED TO BE SETBACK 4-FEET FROM ALL ROOF EDGES UNLESS OTHERWISE SPECIFIED AND CALLED OUT ON THE ARRAY DIAGRAMS ON THIS PAGE OR ON ADDITIONAL ARRAY BALLAST PAGES 4. REFER TO THE SPECIFIC ARRAY BALLAST SHEETS FOR BALLASTING REQUIREMENTS BASED ON THE PROVIDED SITE INFORMATION 5. SYSTEM PSF INCLUDES ALL PANELCLAW RACKING COMPONENTS, MECHANICAL ATTACHMENTS (IF APPLICABLE), PV MODULE AND BALLAST BLOCKS. FOR MAXIMUM SYSTEM POINT LOAD SUMMARY (PLS), REFER TO CALCULATIONS. 6. PANELCLAW AND/OR PANELCLAW CONSULTING ENGINEERS ARE NOT RESPONSIBLE FOR DETERMINING THE ADEQUACY OF THE STRUCTURE TO SUPPORT LOADS IMPOSED BY THE ARRAY AND MOUNTING SYSTEM. SUPPORT STRUCTURE TO BE CHECKED BY OTHERS 7. ALWAYS ALLOW 6” CLEARANCE BETWEEN NEIGHBORING SUBARRAYS, 6” BETWEEN SUBARRAYS AND ALL FIXED ROOF OBJECTS AND 4' BETWEEN SUBARRAYS AND ROOF EDGES. REFER TO LOCAL FIRE CODES AND ELECTRICAL CODES FOR ADDITIONAL REQUIREMENTS WHICH MAY GOVERN DESIGN. SUBARRAYS THAT USE A SEISMIC ANALYSIS METHOD OF DELTA MPV PER SEAOC OR ASCE 7-16 HAVE THEIR OWN CLEARANCE REQUIREMENTS. REFER TO THE BALLAST LAYOUT SHEETS WITHIN THIS DOCUMENT FOR DETAILS. 8. BALLAST BLOCK DIMENSIONS MUST CONFORM TO THE FOLLOWING SPECIFICATIONS: 3-3/4” THICK MAX., 7-5/8” ± 1/8” WIDTH, 15-5/8” ± 1/8” LENGTH. 9. IF AN ARRAY CLEARANCES TABLE APPEARS BELOW ON THIS PAGE, THE DESIGN UTILIZES THIRD PARTY SEISMIC NON-LINEAR RESPONSE ANALYSIS TO ESTIMATE MAXIMUM ARRAY SEISMIC DISPLACEMENT. THE PREDICTED MOVEMENT IS ONLY AN ESTIMATE. PANELCLAW IS NOT RESPONSIBLE OR LIABLE FOR ANY DAMAGES OR COSTS ASSOCIATED WITH PV ARRAY MOVEMENT INCLUDING MOVEMENT IN EXCESS OF THE CLEARANCES NOTED IN THIS DOCUMENT OR ANY REQUIREMENT TO REPOSITION THE ARRAYS IF MOVEMENT OCCURS. 10. DEFLECTORS MUST BE INSTALLED WHEN WINDS ARE EXPECTED TO EXCEED APPROX. 25% OF WIND SPEED DOCUMENTED IN SITE DESIGN CRITERIA TABLE. DEFLECTORS ARE REQUIRED ON ALL MODULES UNLESS OTHERWISE NOTED ON BALLAST LAYOUT PAGES. REQUIRED ARRAY CLEARANCES PER ASCE 7-16 CONDITION MINIMUM SEPARATION DISTANCE (IN.) BETWEEN SEPARATE SOLAR ARRAYS OF SIMILAR CONSTRUCTION (0.5) (Mpv)4 BETWEEN A SOLAR ARRAY AND A FIXED OBJECT ON THE ROOF OR SOLAR ARRAY OF DIFFERENT CONSTRUCTION (Mpv)7 BETWEEN A SOLAR ARRAY AND A ROOF EDGE WITH A QUALIFYING PARAPET (Mpv)7 BETWEEN A SOLAR ARRAY AND A ROOF EDGE WITHOUT A QUALIFYING PARAPET (2.0) (Mpv) >= 4ft 48 NOTE: SUFFICIENT SLACK IN ARRAY ELECTRICAL WIRING MUST BE PROVIDED TO ACCOMMODATE ALL POTENTIAL ARRAY MOVEMENT. SHEET INDEX NO.DESCRIPTION PC-1 COVER SHEET PC-2 PROJECT SUMMARY PC-3 ARRAY SITE MAP PC-4 TYPICAL ARRAY DIMENSIONS PC-5 ASSEMBLIES PC-6 RACKING COMPONENTS PC-7 BALLAST LEGEND PC-8 TO PC-22 BALLAST LAYOUT - 1 TO 15 Site Design Criteria - Flat Roof PV System Basis of Design Roof Live Load (psf)20(see footnote 1) Ground Snow Pg (psf)0 Flat Roof Snow Pf (psf)0 Snow Importance Factor (Is)1.0 Wind Design Data Basic Wind Speed (mph)95 Risk Category II Wind Exposure C Earthquake Design Data Risk Category II Importance Factor (Ie)1.00 Component Importance Factor (Ip)1.0 Mapped Acceleration Parameter (Ss)1.303 Mapped Acceleration Parameter(S1)0.464 Seismic Site Class D Design Spectral Acceleration Parameter (Sds)1.042 Design Spectral Acceleration Parameter (Sd1)0.568 Seismic Design Category (SDC)D Basic seismic-force-resisting system(s)ASCE 7 sec. 13.6.12 Base Design Shear = Fp x W 0.50 W Response Modification Factor (R)2.5 Analysis Procedure ASCE 7 sec. 13.6.12 Design Code (with local amendments)2022 CBC -ASCE 7 - 16 ALTERNATE DESIGN METHOD -SEAOC PV2 1. Roof Live Load only applicable to areas not covered by PV modules. Reference SEAOC Design Guidelines AERIAL PHOTO / SITE DIAGRAM THIS CONSTRUCTION SET PROVIDES THE RACKING LAYOUT FOR ALL ARRAYS WITH NUMBER OF BALLAST BLOCKS AND/OR MECHANICAL ATTACHMENTS BASED ON THE APPROVED STRUCTURAL CALCULATIONS FOR THE COMPLETED INSTALLED CONDITION OF THE SOLAR ARRAY. THE INSTALLER IS RESPONSIBLE FOR THE SAFETY AND CARE OF THE ARRAY DURING ALL PHASES OF INSTALLATION. THEREFORE, THE INSTALLER MUST MONITOR THE WEATHER FORECAST AND TAKE NECESSARY PRECAUTIONS (SEE GENERAL NOTE #10) TO TEMPORARILY SHORE/BRACE ALL ARRAYS DURING CONSTRUCTION UNTIL INSTALLATION IS COMPLETED IN CONFORMANCE WITH THIS APPROVED CONSTRUCTION SET AND THE PRODUCT INSTALLATION MANUAL (SEE GENERAL NOTE #2). THE INSTALLER HAS SOLE RESPONSIBILITY FOR THE MEANS, METHODS, AND TECHNIQUES OF CONSTRUCTION OF THE SOLAR ARRAY FOR COMPLIANCE WITH LAWS, REGULATIONS, AND CODES, AND FOR THE SAFETY OF CONSTRUCTION APPLICABLE TO THIS WORK. APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA COVER SHEET PC-11 24.05.14.1 v3.0.9405.5.2 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 4 Patrick Bair, PE 07/17/2024BY DATE Review is only for general conformance with the design concept and the Contract Documents. Corrections or comments made on this/these documents during review shall not be construed as relieving the contractor from the requirements of the contract documents and specifications. Review does not authorize changes to contract sum unless stated in separate document. Contractor shall be responsible for all detailing, accuracy and correlating sizes, quantities and dimensions for means of assembly. REJECTED SHOP DRAWING / SUBMITTAL REVIEW REVISE AND RESUBMIT REVIEWED AS NOTED REVIEWED (NO EXCEPTIONS TAKEN) APPROVED Provide stamped copy for records. 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: SITE MAP A PC-2NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA PROJECT SUMMARY PC-21 24.05.14.1 v3.0.9405.5.2 clawFRplus 10 Degree - 29 cm PROJECT PART QUANTITY ITEM PART NUMBER QTY Base 500050202 1994 BASE, 02, CFR Module Connector 500063304 1700 MODULE CONNECTOR, 1150, 10D, CFRP Rail 2000895 2308 RAIL, 2500, CFR Cam 5000630 1700 CAM, 10D, CFRP Cam Claw 2000854 1700 CAM CLAW, CFRP Deflector 200088705 850 DEFLECTOR, 10D, 2300, CFR Bolt 2000697 8459 BLT, HEX FLG, TRI, M6X16, GR8.8, PATCH Base Pad 2000678 0 PAD, BASE, CFR CONCRETE MASONRY UNIT N/A 656 BLOCK, CONCRETE, 32.6 LB, - Xin x 8in x 16in NOMINAL, PARTNER SUPPLIED, SEE INSTALLATION MANUAL APPROVED FOR CONSTRUCTION PROJECT SUMMARY MODULE TYPE CANADIAN SOLAR CS6W-530MB-AG MODULE DIMENSIONS (IN.)89.21 X 44.65 X 1.38 NUMBER OF MODULES 850 MODULE WATTAGE (W STC)530 SYSTEM SIZE (kW STC)450.5 SYSTEM WEIGHT (LB)95399 SYSTEM AREA (SQ FT.)29146 AGGREGATE SYSTEM LOAD (PSF)3.27 NUMBER OF ARRAYS 15 ARRAY TILT (DEG)8.99 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 Roof 1 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY SITE MAP A PC- NTS EXISTING ROOF PERIMETER ARRAY # (TYP) ROOF SETBACK (TYP) KEEPOUTS (TYP) # RACKING CONSTRUCTION SET NOTES: 1. ALL DIMENSIONS SHOWN ARE BASED UPON INFORMATION PROVIDED TO PANELCLAW. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION OF THE SOLAR ARRAY. NOTIFY PANELCLAW OF ANY DISCREPANCIES. APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA ARRAY SITE MAP PC-31 24.05.14.1 v3.0.9405.5.2 ROOF NAME ROOF SETBACK (FT.) ROOF HEIGHT (FT) PARAPET HEIGHT (FT) ROOF TILT (DEG) Roof 1 10.00 20.00 2.0 2 KEEPOUT NAME KEEPOUT CLEARANCE (FT.) KEEPOUT HEIGHT (IN.) Group 1 4 24 Group 2 4 96 Group 3 4 72 Group 4 4 48 Group 5 0.5 6 Group 6 2 24 3 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 180' 15' 79' 1' 60' 1' 39' 105' 40' 219' 319' 134' 23' 2'24' 56' 1' 9' 1'2'6' 51' 6'2'1' 9' 0' 12' 1' 33' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1330 E Seventeenth St4/10/2025 'L' RAIL INSTALLATION: USE THE OUTER SET OF HOLES WHEN INSTALLING RAILS BETWEEN MODULES. RAIL ON “L” SPACING IS ALWAYS ON TOP OF RAIL ON “S” SPACING. THIS INSTALLATION SEQUENCE IS CRITICAL TO SYSTEM PERFORMANCE. FOR MORE INFORMATION REVIEW THE INSTALLATION MANUAL AND VIDEOS. A (REPEAT DIMENSION EAST-WEST) PL (PANEL LENGTH) M (PROJECTED PANEL WIDTH) B (REPEAT DIMENSION NORTH-SOUTH) C J PT P D PW D ° O W K X 18 mm (0.709 in) N G 32 . 9 m m ( 1 . 2 9 5 i n ) S (ON-MODULE BASE SPACING) L (BETWEEN-MODULE BASE SPACING) R AEBE RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY TOP VIEW B NTSSCALE: ARRAY CROSS SECTION VIEW A NTS SCALE: RAIL DETAIL C NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 24.05.14.1 v3.0.9405.5.2 INSTALLED ARRAY DIMENSIONS A B C D G J K M N O P R W X Theta (DEG) D/J (#:1)G.C.R.* mm 2284 1398 121 278 116 177 209 1120 81 59 92 516 253 137 8.99 1.57 0.81UNITS inches 89.92 55.05 4.75 10.96 4.56 6.97 8.23 44.10 3.20 2.31 3.61 20 5/16 9.95 5.39 8.99 1.57 0.81 * G.C.R = (PW) / B INSTALLATION MEASUREMENTS AEBE S L CAM SPACING* mm 486 1234 1050 53UNITS inches 19 1/8 48 9/16 41 5/16 2 1/8 *CAM SPACING SHOWN ON ASSEMBLIES PAGE. MODULE DIMENSIONS PL PW PT mm 2266 1134 35UNITS inches 89.21 44.65 1.38 PC-4 PC-4 PC-4 TYPICAL ARRAY DIMENSIONS PC-4 APPROVED FOR CONSTRUCTION 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1330 E Seventeenth St4/10/2025 BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1" BASE HOLE "3" BASE HOLE "1" BASE HOLE "3"BASE HOLE "3" BASE HOLE "1" BASE HOLE "3" BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER CAM SPACING RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM SPACING DETAIL A NTS SCALE: NORTH ASSEMBLY B NTS SCALE: SOUTH ASSEMBLY D NTS SCALE: MIDDLE ASSEMBLY C NTS SCALE: NORTH SOUTH ASSEMBLY E NTS SCALE: EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA ASSEMBLIES PC-51 24.05.14.1 v3.0.9405.5.2 APPROVED FOR CONSTRUCTION 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 274 SOUTH ASSEMBLY 274 MIDDLE ASSEMBLY 1132 NORTH SOUTH ASSEMBLY 20 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 53UNITS inches 2 1/8 1330 E Seventeenth St4/10/2025 NOTE: EXAMPLE BALLASTING SHOWN ON THIS PAGE IS FOR REFERENCE ONLY AND DO NOT REFLECT TYPICAL BALLAST PLACEMENT. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST REQUIREMENTS. BASE RAIL DEFLECTOR CAM BRACKET AND CAM CLAW TRANSPARENT MODULE MODULE CONNECTOR RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: CAM BRACKET C NTS SCALE: CAM CLAW B NTS SCALE: RAIL F NTS SCALE: BASE D NTS SCALE: MODULE CONNECTOR E NTSSCALE: DEFLECTOR G NTS SCALE: EXAMPLE RAIL AND BLOCK CONFIGURATION A NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 APPROVED FOR CONSTRUCTION PC-6 RACKING COMPONENTS 24.05.14.1 v3.0.9405.5.2 PC-6 PC-6 PC-6 PC-6 PC-6 PC-6PC-6 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1330 E Seventeenth St4/10/2025 MECHANICAL ATTACHMENT AT INDICATED LOCATION NOTE: EXAMPLE BALLAST AND ATTACHMENTS SHOWN ON THIS PAGE ARE FOR REFERENCE ONLY. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST/ATTACHMENT REQUIREMENTS. BALLAST QUANTITY: "#"=QUANTITY OF BALLAST BLOCK INSTALLED CENTERED UNDER MODULE IF NO BALLAST QUANTITY SHOWN, DO NOT PLACE BALLAST SEE INSTALLATION MANUAL FOR NOTES ON INSTALLING MORE THAN FOUR BALLAST BLOCKS PER MODULE DO NOT INSTALL ADDITIONAL RAIL TO HOLD BALLAST ON MODULES WITH NO BALLAST SHOWN. MODULES LONGER THAN 2100 MM WITH 7 OR 8 BALLAST BLOCKS REQUIRE TWO (2) RAILS. 6 2 2 2 4 2 85 5 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY TOP VIEW B NTSSCALE: ARRAY CROSS SECTION VIEW A NTS RACKING CONSTRUCTION SET PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA 1 PC-7 BALLAST LEGEND APPROVED FOR CONSTRUCTION 24.05.14.1 v3.0.9405.5.2 PC-7 PC-7 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.1 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 46 MODULE POWER (W)530 ARRAY OUTPUT (Kw)24.38 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 114 Module Connector 92 Rail 149 Cam 92 Cam Claw 92 Deflector 46 Base Pad 0 Ballast Block 113 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)7745 ARRAY AREA (SQ. FT)1576 ARRAY LOAD (PSF)4.92 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.1 PC-81 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.1 PC-8 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 31 2 2 3 4 3 2 3 4 2 3 4 1 2 2 1 2 1 34 1 1 2 12 1 5 1 26 4 2 1 2 4 3 2 4 24 26 3 82.51' 44.90' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 16 SOUTH ASSEMBLY 16 MIDDLE ASSEMBLY 54 NORTH SOUTH ASSEMBLY 6 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.2 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 196 MODULE POWER (W)530 ARRAY OUTPUT (Kw)103.88 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 436 Module Connector 392 Rail 488 Cam 392 Cam Claw 392 Deflector 196 Base Pad 0 Ballast Block 85 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)19724 ARRAY AREA (SQ. FT)6727 ARRAY LOAD (PSF)2.93 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.2 PC-91 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.2 PC-9 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 2 2 1 1 2 1 211 2 21 2 73.33' 127.33' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 40 SOUTH ASSEMBLY 40 MIDDLE ASSEMBLY 308 NORTH SOUTH ASSEMBLY 4 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.3 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 26 MODULE POWER (W)530 ARRAY OUTPUT (Kw)13.78 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 60 Module Connector 52 Rail 71 Cam 52 Cam Claw 52 Deflector 26 Base Pad 0 Ballast Block 25 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)3079 ARRAY AREA (SQ. FT)892 ARRAY LOAD (PSF)3.45 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.3 PC-101 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.3 PC-10 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 1 1 2 1 1 1 1 1 1 1 1 2 1 2 1 2 2 45.81' 29.92' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 8 SOUTH ASSEMBLY 8 MIDDLE ASSEMBLY 36 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.4 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 48 MODULE POWER (W)530 ARRAY OUTPUT (Kw)25.44 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 132 Module Connector 96 Rail 165 Cam 96 Cam Claw 96 Deflector 48 Base Pad 0 Ballast Block 48 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)5835 ARRAY AREA (SQ. FT)1641 ARRAY LOAD (PSF)3.56 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.4 PC-111 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.4 PC-11 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 22 2 2 1 2 2 11 1 1 2 1 1 2 1 1 1 2 1 1 1 2 2 2 2 1 2 2 2 2 22.87' 134.82' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 34 SOUTH ASSEMBLY 34 MIDDLE ASSEMBLY 26 NORTH SOUTH ASSEMBLY 2 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.5 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 54 MODULE POWER (W)530 ARRAY OUTPUT (Kw)28.62 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 144 Module Connector 108 Rail 162 Cam 108 Cam Claw 108 Deflector 54 Base Pad 0 Ballast Block 26 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)5598 ARRAY AREA (SQ. FT)1847 ARRAY LOAD (PSF)3.03 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.5 PC-121 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.5 PC-12 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 21 1 1 2 1 1 1 1 1 11 1 1 1 1 1 1 12 1 2 13.70' 134.82' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 36 SOUTH ASSEMBLY 36 MIDDLE ASSEMBLY 36 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.6 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 50 MODULE POWER (W)530 ARRAY OUTPUT (Kw)26.5 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 114 Module Connector 100 Rail 131 Cam 100 Cam Claw 100 Deflector 50 Base Pad 0 Ballast Block 35 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)5482 ARRAY AREA (SQ. FT)1715 ARRAY LOAD (PSF)3.20 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.6 PC-131 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.6 PC-13 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 2 1 1 1 2 1 1 1 1 1 2 1 1 2 2 1 1 1 1 1 2 1 1 2 2 50.40' 52.40' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 14 SOUTH ASSEMBLY 14 MIDDLE ASSEMBLY 72 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.7 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 26 MODULE POWER (W)530 ARRAY OUTPUT (Kw)13.78 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 62 Module Connector 52 Rail 69 Cam 52 Cam Claw 52 Deflector 26 Base Pad 0 Ballast Block 19 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)2881 ARRAY AREA (SQ. FT)891 ARRAY LOAD (PSF)3.23 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.7 PC-141 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.7 PC-14 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 1 1 1 1 2 1 1 1 2 1 2 2 27.46' 37.41'ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 10 SOUTH ASSEMBLY 10 MIDDLE ASSEMBLY 32 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.8 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 186 MODULE POWER (W)530 ARRAY OUTPUT (Kw)98.58 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 422 Module Connector 372 Rail 490 Cam 372 Cam Claw 372 Deflector 186 Base Pad 0 Ballast Block 122 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)20128 ARRAY AREA (SQ. FT)6381 ARRAY LOAD (PSF)3.15 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.8 PC-151 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.8 PC-15 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/12" = 1'-0" 21 1 1 1 1 2 11 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 2 1 2 2 1 1 1 1 1 1 2 2 2 2 1 1 1 1 2 2 1 2 2 1 2 2 1 1 2 1 1 1 1 2 1 2 1 1 1 1 1 1 2 2 1 1 2 1 1 2 2 2 1 2 1 2 1 1 2 1 2 2 2 2 87.10' 134.82' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 50 SOUTH ASSEMBLY 50 MIDDLE ASSEMBLY 272 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.9 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 106 MODULE POWER (W)530 ARRAY OUTPUT (Kw)56.18 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 230 Module Connector 212 Rail 255 Cam 212 Cam Claw 212 Deflector 106 Base Pad 0 Ballast Block 48 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)10709 ARRAY AREA (SQ. FT)3639 ARRAY LOAD (PSF)2.94 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.9 PC-161 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.9 PC-16 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 1 2 1 2 2 2 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 2 2 1 1 2 1 1 2 73.33' 67.38' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 18 SOUTH ASSEMBLY 18 MIDDLE ASSEMBLY 176 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.10 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 18 MODULE POWER (W)530 ARRAY OUTPUT (Kw)9.54 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 46 Module Connector 36 Rail 53 Cam 36 Cam Claw 36 Deflector 18 Base Pad 0 Ballast Block 17 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)2134 ARRAY AREA (SQ. FT)616 ARRAY LOAD (PSF)3.46 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.10 PC-171 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.10 PC-17 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 1 11 1 1 1 1 2 2 2 2 27.46' 37.41'ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 8 SOUTH ASSEMBLY 8 MIDDLE ASSEMBLY 18 NORTH SOUTH ASSEMBLY 2 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.11 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 34 MODULE POWER (W)530 ARRAY OUTPUT (Kw)18.02 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 80 Module Connector 68 Rail 95 Cam 68 Cam Claw 68 Deflector 34 Base Pad 0 Ballast Block 42 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)4336 ARRAY AREA (SQ. FT)1166 ARRAY LOAD (PSF)3.72 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.11 PC-181 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.11 PC-18 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 21 2 1 1 1 1 2 2 1 21 12 22 22 22 22 12 1 2 59.57' 37.41' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 10 SOUTH ASSEMBLY 10 MIDDLE ASSEMBLY 46 NORTH SOUTH ASSEMBLY 2 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.12 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 36 MODULE POWER (W)530 ARRAY OUTPUT (Kw)19.08 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 86 Module Connector 72 Rail 103 Cam 72 Cam Claw 72 Deflector 36 Base Pad 0 Ballast Block 32 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)4190 ARRAY AREA (SQ. FT)1234 ARRAY LOAD (PSF)3.40 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.12 PC-191 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.12 PC-19 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 21 2 1 2 1 2 1 1 1 1 2 2 1 1 1 1 1 2 2 1 1 2 27.46' 52.40'ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 14 SOUTH ASSEMBLY 14 MIDDLE ASSEMBLY 44 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.13 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 8 MODULE POWER (W)530 ARRAY OUTPUT (Kw)4.24 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 24 Module Connector 16 Rail 27 Cam 16 Cam Claw 16 Deflector 8 Base Pad 0 Ballast Block 16 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)1234 ARRAY AREA (SQ. FT)273 ARRAY LOAD (PSF)4.52 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.13 PC-201 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.13 PC-20 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 3 2 3 2 222 13.70' 29.92' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 4 SOUTH ASSEMBLY 4 MIDDLE ASSEMBLY 4 NORTH SOUTH ASSEMBLY 4 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.14 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 10 MODULE POWER (W)530 ARRAY OUTPUT (Kw)5.3 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 26 Module Connector 20 Rail 30 Cam 20 Cam Claw 20 Deflector 10 Base Pad 0 Ballast Block 15 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)1368 ARRAY AREA (SQ. FT)342 ARRAY LOAD (PSF)4.00 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.14 PC-211 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.14 PC-21 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 2 2 1 2 2 2 2 2 18.28' 22.42' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 6 SOUTH ASSEMBLY 6 MIDDLE ASSEMBLY 8 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INC ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS PROPERTY OF PANELCLAW, INC. THE PURPOSE OF THIS DOCUMENT IS TO FACILITATE THE INSTALLATION OF PANELCLAW SOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0" 1/2" 1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION: SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.15 ROOF INFORMATION ROOF HEIGHT (FT)20.00 PARAPET HEIGHT (FT)2.0 ROOF TILT (DEG)2 ROOF TYPE PVC SPECIFICATIONS NUMBER OF MODULES 6 MODULE POWER (W)530 ARRAY OUTPUT (Kw)3.18 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 18 Module Connector 12 Rail 20 Cam 12 Cam Claw 12 Deflector 6 Base Pad 0 Ballast Block 13 LOADING DETAILS SINGLE MODULE WT (LB)71.0 SINGLE CMU WT (LB)32.6 TOTAL ARRAY WT (LB)958 ARRAY AREA (SQ. FT)205 ARRAY LOAD (PSF)4.68 REQUIRED CLEARANCES PER ASCE 7-16 CONDITION 1 (in.)4 CONDITION 2 (in.)7 CONDITION 3 (in.)7 CONDITION 4 (in.)48 APPROVED FOR CONSTRUCTION PowerFlex CA Target T0286 Santa Ana 1330 17th Street, Santa Ana, CA, USA BALLAST LAYOUT - 1.15 PC-221 24.05.14.1 v3.0.9405.5.2 BALLAST LAYOUT - 1.15 PC-22 1 Re v i s e d B a l l a s t M a p L a y o u t RH 20 2 4 - 0 6 - 0 7 0 In i t i a l L a y o u t M M 20 2 4 - 0 5 - 2 8 1/6" = 1'-0" 3 3 23 2 9.11' 22.42' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 6 SOUTH ASSEMBLY 6 MIDDLE ASSEMBLY 0 NORTH SOUTH ASSEMBLY 0 1330 E Seventeenth St4/10/2025 MORE POWER MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 545 W 545 W Minimizes micro-crack impacts Heavy snow load up to 5400 Pa, wind load up to 2400 Pa* Better shading tolerance 30 12 Years Years BiHiKu6 520 W ~ 545 W BIFACIAL MONO PERC CS6W-520|525|530|535|540|545MB-AG FRONT BACK Compatible with mainstream trackers, cost effective product for utility power plant Up to 12.3 % lower LCOE Up to 5.2 % lower system cost PRODUCT CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system ISO 45001: 2018 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES* products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. *According to the applicable Canadian Solar Limited Warranty Statement. Enhanced Product Warranty on Materials and Workmanship* Linear Power Performance Warranty* 1 st year power degradation no more than 2% Subsequent annual power degradation no more than 0.45% IEC 61215 / IEC 61730 / CE / INMETRO / MCS / UKCA CEC listed (US California) UL 61730 / IEC 61701 / IEC 62716 / IEC 60068-2-68 Take-e-way 1330 E Seventeenth St4/10/2025 PARTNER SECTION ELECTRICAL DATA | STC* Nominal Max. Power (Pmax) Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Module CS6W-520MB-AG 520 W 40.5 V 12.84 A 48.4 V 13.70 A 20.2% Bifacial Gain** 5% 546 W 40.5 V 13.48 A 48.4 V 14.39 A 21.2% 10% 572 W 40.5 V 14.12 A 48.4 V 15.07 A 22.3% 20% 624 W 40.5 V 15.41 A 48.4 V 16.44 A 24.3% CS6W-525MB-AG 525 W 40.7 V 12.90 A 48.6 V 13.75 A 20.4% Bifacial Gain** 5% 551 W 40.7 V 13.55 A 48.6 V 14.44 A 21.4% 10% 578 W 40.7 V 14.21 A 48.6 V 15.13 A 22.5% 20% 630 W 40.7 V 15.48 A 48.6 V 16.50 A 24.5% CS6W-530MB-AG 530 W 40.9 V 12.96 A 48.8 V 13.80 A 20.6% Bifacial Gain** 5% 557 W 40.9 V 13.62 A 48.8 V 14.49 A 21.7% 10% 583 W 40.9 V 14.26 A 48.8 V 15.18 A 22.7% 20% 636 W 40.9 V 15.55 A 48.8 V 16.56 A 24.8% CS6W-535MB-AG 535 W 41.1 V 13.02 A 49.0 V 13.85 A 20.8% Bifacial Gain** 5% 562 W 41.1 V 13.68 A 49.0 V 14.54 A 21.9% 10% 589 W 41.1 V 14.34 A 49.0 V 15.24 A 22.9% 20% 642 W 41.1 V 15.62 A 49.0 V 16.62 A 25.0% CS6W-540MB-AG 540 W 41.3 V 13.08 A 49.2 V 13.90 A 21.0% Bifacial Gain** 5% 567 W 41.3 V 13.73 A 49.2 V 14.60 A 22.1% 10% 594 W 41.3 V 14.39 A 49.2 V 15.29 A 23.1% 20% 648 W 41.3 V 15.70 A 49.2 V 16.68 A 25.2% CS6W-545MB-AG 545 W 41.5 V 13.14 A 49.4 V 13.95 A 21.2% Bifacial Gain** 5% 572 W 41.5 V 13.80 A 49.4 V 14.65 A 22.3% 10% 600 W 41.5 V 14.46 A 49.4 V 15.35 A 23.3% 20% 654 W 41.5 V 15.77 A 49.4 V 16.74 A 25.5% * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell tempe- rature of 25°C. ** Bifacial Gain: The additional gain from the back side compared to the power of the front side at the standard test condition. It depends on mounting (structure, height, tilt angle etc.) and albedo of the ground. ENGINEERING DRAWING (mm) Rear View ELECTRICAL DATA | NMOT* Nominal Max. Power (Pmax) Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) CS6W-520MB-AG 390 W 38.0 V 10.27 A 45.7 V 11.05 A CS6W-525MB-AG 394 W 38.2 V 10.32 A 45.9 V 11.09 A CS6W-530MB-AG 397 W 38.3 V 10.38 A 46.1 V 11.13 A CS6W-535MB-AG 401 W 38.5 V 10.42 A 46.3 V 11.17 A CS6W-540MB-AG 405 W 38.7 V 10.47 A 46.5 V 11.21 A CS6W-545MB-AG 409 W 38.9 V 10.52 A 46.7 V 11.25 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. 35 23 Mounting Hole CS6W-530MB-AG / I-V CURVES 7 10 R 9 14 R ELECTRICAL DATA Operating Temperature -40°C ~ +85°C Max. System Voltage 1500 V (IEC/UL) or 1000 V (IEC/UL) Module Fire Performance TYPE 29 (UL 61730) or CLASS C (IEC61730) Max. Series Fuse Rating 30 A Class A Power Tolerance Power Bifaciality* 70 % * Power Bifaciality = Pmaxrear / Pmaxfront, both Pmaxrear and Pmaxfront are tested under STC, Bifaciality Tolerance: ± 5 % MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement Dimensions Weight 32.2 kg (71.0 lbs) Front Glass 2.0 mm heat strengthened glass with anti- Back Glass 2.0 mm heat strengthened glass Frame Anodized aluminium alloy J-Box IP68, 3 bypass diodes Cable 4.0 mm² (IEC), 12 AWG (UL) Cable Length (Including Connector) 410 mm (16.1 in) (+) / 290 mm (11.4 in) (-) or customized length* Connector T4 or MC4 series Per Pallet 30 pieces Per Container (40‘ HQ) 600 pieces or 540 pieces (only for US) * For detailed information, please contact your local Canadian Solar sales and technical representatives. Frame Cross Section A-A TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A V A 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 06 55 05 54 04 53 03 52 02 51 01 5 06 55 05 54 04 53 03 52 02 51 01 5 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 ~ + 10 W products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. have professional skills and please carefully read the safety and installation instructions before using our PV modules. 35 AA 1105 1134 50 50 6- 5 Grounding Hole 40 0 79 0 11 5 5 8-10x7 Mounting Hole(tracker) 4-14x9 Mounting Hole 22 6 6 Feb. 2022 | All rights reserved | PV Module Product Datasheet v2.0_F42_J2_NACSI SOLAR (USA) CO., LTD. 1330 E Seventeenth St4/10/2025 Presented by: Feasibility Structural Analysis of Building for a Proposed Rooftop Solar PV System N Grand Ave & 17th St, Santa Ana, CA 92705 Target T0286 - Santa Ana For The Project: Presented to: 805 Third Avenue, 14th Floor New York, NY 10022 Rev. 0 Pure Power Engineering, Inc. 111 River Street - Suite 1110 Hoboken, NJ 07030 www.PurePower.com (201) 687-9975 December 7, 2022 Ying Liu, PE Drit Sokoli, Ph.D PPE Project No. PPE-05184.03 Ahmed Youssef, PE 1330 E Seventeenth St4/10/2025 Table of Contents Executive Summary Reserved Load/Snow Drift Plan(s) Standard Conditions for Engineering Services on Existing Structures Codes and Design Criteria Analysis Assumptions Conclusion Target T0286 - Santa Ana - Feasibility Report PPE-05184.03 Table of Contents Checked by AY Prepared by DS 12/7/2022 1.1 3.1 - 3.2 4.1 5.1 6.1 2.1 1330 E Seventeenth St4/10/2025 Executive Summary • Existing building is feasible for PV solar system. • Reserved capacity and maximum allowable deck loads for the existing roof: Reserved Capacity = Maximum system weight = Deck Downward = (controlled by 2x4 purlin for point load spaced at 4.0 ft o.c.) Assuming using U-Anchor 2400/2600 with 8-#14 fasteners and w/ PanelClaw racking system with U-bracket Uplift = Shear = 0 (in a 2.0' wide strip X 6.5' long spans, point loads spaced at 3.0' and 3.7' o.c.) Assuming using OMG PowerGrip Plus with 8-#14 fasteners and w/ PanelClaw racking system with U-bracket Uplift = Shear = 0 Assuming using Facet with 8-#14 fasteners and w/ PanelClaw racking system with U-bracket Uplift = Shear = Notes: Existing Structure Target T0286 - Santa Ana - Feasibility Report PPE-05184.03 12/7/2022 A (PV) Solar Array is proposed to be installed with modules mounted to a ballasted (and/or mechanically attached) racking system and supported on the rooftop of the subject building. Pure Power has performed a structural analysis and determined the following: 320.0 lb Sheet 1.1 Prepared by DS 315 lb 224,084 lb Checked by AY 6.0 psf The original structure is Target T0286 - Santa Ana building located at N Grand Ave & 17th St, Santa Ana, CA 92705. The referenced building is a one story wood frame structure, which was built circa 1966. The approximate total area is 107370 square feet. Typical roof construction consists of 1/2 Plywood Deck (assumed) supported by wood joists spaced at 1'-4" o.c., supported by wood purlins spaced at 8'-0" o.c. Purlins are supported by girders spaced at 30' o.c. 350.0 lb 335 lb 200 lb • The allowable deck loads will be dependent on the racking system used. At the time of the writing of this report, this information was not available. The allowable deck loads are subject to change upon receiving this information. • Racking manufacturer shall select the racking system such that satisfies both the above specified uniform load reserve capacities and the maximum allowable downward, uplift and shear loads on the roof deck, respectively. All allowable capacities listed above are based on min. 0.5" penertration in existing plywood sheathing. 450 lb 200 lb 333 lb 1330 E Seventeenth St4/10/2025 Reserved Load Plan Target T0286 - Santa Ana - Feasibility Report 12/7/2022 Sheet 2.1 Prepared by DS PPE-05184.03 Checked by AY (Blue Shaded Area) Reserved Capacity = 6 psf No PV in the Red Shaded Areas 1330 E Seventeenth St4/10/2025 Standard Conditions for Engineering Services on Existing Structures Proposed PV-Panels and Preliminary Design Target T0286 - Santa Ana - Feasibility Report 12/7/2022 Sheet 3.1 Prepared by DS Checked by AY • PV solar panels shall be installed on the roof as arrays on a ballasted racking system. A typical ballasted racking system is designed to resist wind uplift and sliding by placing concrete blocks (ballast) as counterweight on the racks. The system does not increase uplift on the building because the ballast should be designed to resist the additional uplift in order to provide the code required factor of safety. • If the PV racking system is mechanically attached to the roof deck, then the uplift and shear forces at each mechanical attachment are not to exceed the capacity noted in this report under the conclusion section. • It is assumed that the panels will be approximately 12 inches above the rooftop at the high end. • It is assumed that the average design weight includes the weight of the panels, racking system and the ballast and all required assemblies. PPE-05184.03 • The analysis is based on the information gathered from the field and/or information provided to Pure Power Engineering and is assumed to be current and accurate. • Unless noted otherwise, the structure and the foundation system are assumed to be in good condition, free of defects, and can achieve theoretical strength. • It is assumed that the structure has been properly maintained and shall be properly maintained during its service. The superstructure and the foundation system are assumed to be designed with proper engineering practice and fabricated, constructed and erected in accordance with the design documents. Pure Power will accept no liability which may arise due to any existing deficiency in design, material, fabrication, erection, construction, etc. or lack of maintenance. • The analysis results are only applicable for the proposed additions and alterations specified in this report. Any deviation of the proposed equipment and placement, etc., will require Pure Power to generate an additional structural analysis. • The analysis does not include the design of the racking system or the ballast it requires. The analysis is performed to verify the capacity of the main structural system. Connections are assumed to have the capacity of the main structural members. • Pure Power assumes that the existing building has NOT been modified or altered from its original design. Building landlord/client shall inform PPE with any kind of modification and/or alteration that may have been done to the existing building during its lifetime. 1330 E Seventeenth St4/10/2025 Existing Building Code Allowance Target T0286 - Santa Ana - Feasibility Report PPE-05184.03 Checked by AY • Pursuant to CA Existing Building Code section 502.4, any existing gravity load-carrying structural element for which additions and/or alterations cause an increase in design gravity load of no more than 5 percent, shall be permitted to remain unaltered, thus considered to be code-compliant and adequate. Any existing gravity load- carrying structural element for which additions and/or alterations cause an increase in design gravity loads exceeding 5 percent is checked against the applicable Code criteria for new structures. • Pursuant to CA Existing Building Code Sections 502.5, any existing lateral load-carrying structural element whose demand-capacity ratio with the addition and/or alteration considered is no more than 10 percent greater than its demand-capacity ratio with the addition and/or alteration ignored shall be permitted to remain unaltered, thus considered to be Code-compliant and adequate. If the demand- capacity ratio increase is more than 10 percent, the subject structural element is checked against the applicable Code criteria for new structures. • Pursuant International Building Code section 1607A.13.5.1, where PV panels are installed on building roof, it is not necessary to include roof live load in the area(s) covered by the panels when these area(s) are inaccessible, or signs are posted prohibiting storage under the panels. Therefore, Pure Power has applied the roof live/snow load in all areas that are still accessible and subject to foot traffic, maintenance workers, storage, etc., but not directly under the modules. Sheet 3.2 12/7/2022 Prepared by DS 1330 E Seventeenth St4/10/2025 Codes and References 2019 California Building Code, Adopting 2018 International Building Code with Amendments Minimum Design Loads for Buildings and Other Structures, ASCE 7-16 2018 National Design Specification, NDS, by the American Wood Council Design Criteria Snow Load (Service) Ground Snow Load: Risk Category: Snow Exposure: Ce: Snow Load Important Factor Is: Thermal Factor Ct: Flat Snow Load: Roof Live Load (Service) Wind Load Risk Category: Ultimate Wind Speed: Exposure Category: Seismic Load Risk Category: Ie, Seismic Importance Factor: Site Class: SS, Mapped spectral response acceleration at short periods: SDS, Design spectral response acceleration at short periods: S1, Mapped spectral response acceleration at 1s period: SD1, Design spectral response acceleration at 1s period: Seismic Design Category: Target T0286 - Santa Ana - Feasibility Report Checked by AY 12/7/2022 Sheet 4.1 Prepared by DS 0 psf II 1.0 II 1.255 0.664 0.575 94 mph 1.0 1.0 20.0 psf II 1.00 C 1.882 0.0 psf B Note: The racking manufacturer/the racking manufacturer’s structural engineer shall be responsible to verify the design criteria when designing the racking system. PPE-05184.03 D 1330 E Seventeenth St4/10/2025 Analysis Assumptions for Existing Roof The proposed PV system is to weigh a maximum Therefore, the proposed loading, including the weight of the PV system is as follows: Roofing & Insulation Plywood Sheathing Wood Framing MEP, Sprinklers & Ceiling Total Roof DL = PV System Weight Roof SL = Total Roof Load = Target T0286 - Santa Ana - Feasibility Report Sheet 5.1 Prepared by DS The building was analyzed based on the construction drawings by John E Mackel and Associates - Consulting Structural Engineers dated 02/25/1966. 5.0 psf 12/7/2022 Checked by AY PPE performed structural analysis for the roof elements. It was found that the weight of the proposed solar array with ballasts plus the design roof dead load did not exceed the members capacity. Therefore, the structure may remain unaltered. PPE-05184.03 13.5 psf 6.0 psf 0.0 psf 19.5 psf 2.0 psf 1.5 psf 5.0 psf PPE understands that the area where the clear space between the panels and rooftop is not more than 24 in. Therefore, as per the current state code (section 1607A.13.5.1), roof live load does NOT need to be considered on areas where the proposed PV system will be installed. 6.0 psf 1330 E Seventeenth St4/10/2025 Conclusion Sincerely, Ying Liu, PE Ahmed Youssef, PE Drit Sokoli, Ph.D Target T0286 - Santa Ana - Feasibility Report 12/7/2022 Sheet 6.1 Prepared by DS Based on our experience and engineering analysis of the information available at the time of this writing, it is the opinion of this organization that the added stresses due to the weight of the proposed PV modules are considered acceptable and will not exceed the capacity of the existing roof structure. The proposed PV modules may be installed at Target T0286 - Santa Ana under the conditions outlined in the body of this report. Do not stage pallets on roof unless staging plan drawing is provided by PPE. This report does not represent an approval of the proposed PV system design. It is the racking designer’s responsibility to ensure any proposed racking system is within the limits stated in this report and their system is designed in accordance with the requirements in the governing building code. PPE can review the existing framing adequacy for anchorage reaction loads upon request and if the racking design are supplied to PPE by the racking designer. PPE-05184.03 Checked by AY 1330 E Seventeenth St4/10/2025