HomeMy WebLinkAbout1311 N Towner - PlanEX TREES 116'-3" 26'-8" NORTH Existing Site Plan Scale: 1/8"=1'0" UTILITY LINE - SEWER PROPERTY LINE (E) LANDSCAPE (E ) P A R K W A Y (E ) S I D E W A L K 16 ' - 1 " (E)POWER POLE (E) 100 AMP. ELEC. METER(E) DRIVEWAY EXISTING GARAGE 422 SQ. FT. EXISTING MAIN S.F.R 1,504 SQ. FT. NOT A PART OF SCOPE WATER METER GAS METER UP PROPERTY LINE 116.22' PR O P E R T Y L I N E 6 0 . 0 0 ' PROPERTY LINE 116.22' PR O P E R T Y L I N E 6 0 . 0 2 ' PROPERTY LINE 119.81' PR O P E R T Y L I N E 6 0 . 0 0 ' PROPERTY LINE 119.81' PR O P E R T Y LI N E 6 0 . 0 2 ' 26'-7" 24'-0" 7'-5" 8'-0"11'-9" 6'-10" 5'-0" 60 ' - 0 " 18 ' - 8 " 22 ' - 8 " 18 ' - 1 " 18 ' - 3 " 5' - 0 " 119'-10" 5'-0"12'-3" 33'-0" 34'-4" 27'-3" 30'-0" 5'-0"6'-11" 30'-0" 20 ' - 4 " 6' - 0 " 8'-0" CENTERLINE LINE SITE PLAN LEGEND W WUTILITY LINE - WATER GAS GAS GAS GASUTILITY LINE - GAS S S (E) BUILDING LINE (N) BUILDING EU EU EO EOUTILITY LINE - ELECTRIC OVERHEAD SERVICE UTILITY LINE - ELECTRIC UNDERGROUND SERVICE DRAIN FLOWLINE 7'-0" 5'-0" 12'-0" (E) LANDSCAPE (E) LANDSCAPE 7' - 6 " 6' - 0 " 6' - 2 " 21 ' - 6 " 10 ' - 3 " 12 ' - 2 " 8' - 1 1 " 10 ' - 3 " 11'-11" (E ) D R I V E W A Y AP P R O A C H NOT A PART OF SCOPE (E) CONC. WALKWAY SLAB (E) CONC. SLAB (E) CONC. SLAB (E) CONC. WALKWAY SLAB 60 ' - 0 " EXISTING BUILDING 216 SQ. FT. (E) CONC. WALKWAY SLAB UP 162 S.F. ADDITION UNDER SEPARATE PERMIT (101119806) NEW TANK-LESS WATER HEATER LOCATION GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS (E) 1" GAS LINE GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS (N) GAS LINE FOR WATER HEATER REVISION(S) 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M 24-107 MAY 2024 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 1 10/14/2024 11/05/2024 1/8"=1'0" (EX) SITE PLAN 1.0 NOTE: *SITE MEASUREMENTS OF THE PROPERTY LINE BOUNDARIES ARE AN ASSUMPTION AND ARE PRESENTED AS IS, WITH NO GUARANTEE OF ACCURACY OR COMPLETENESS. INFORMATION USED HERE IS CREATED FROM PUBLIC RECORDS AND EXISTING MAP SOURCES, NOT DIRECTLY FROM FIELD SURVEYS. THE PRECISE LOCATION OF PROPERTY BOUNDARIES MUST BE DETERMINED BY A LAND SURVEYOR REGISTERED TO PRACTICE IN THE STATE OF CALIFORNIA. PRIOR TO ANY COMMENCEMENT OF WORK IT IS THE OWNER(S)/CONTRACTOR RESPONSIBILITY TO VERIFY ALL PROPERTY BOUNDARIES THROUGH THE SERVICES OF A REGISTERED LAND SURVEYOR. AREA OF WORK 2 22 BLDG# 101120795 APPROVALS BLDG- CSG Consultants PLNG- CSantana 1311 N Towner 12/12/2024 (E) Bathroom 62 S.F. (E ) C l o s e t (E) Landing (E) Landing (E) Living Room 292 S.F. (E) Entrance 41 S.F. (E) Dining Room 159 S.F. (E) Kitchen 147 S.F. (E) Bedroom #1 161 S.F. (E) M. Bedroom 200 S.F. (E) Closet (E) Linen (E) Linen (E) Laundry 47 S.F. (E) Hallway 53 S.F. (E) Linen (E) WIC 46 S.F. (E) M. Bathroom 116 S.F. ROOF LEGEND (E) ASPHALT SHINGLES 3'-4" Existing Main House Floor Plan Scale: 1/4"=1'0" NO R T H NO R T H Existing Roof Plan Scale: 1/4"=1'0" 2'-1"4'-4" 17 ' - 1 0 " 7' - 5 " 11 ' - 3 " REF. 19 ' - 2 " 15'-3" 6' - 8 " 6'-2" 11'-9" 13 ' - 6 " 8'-6" 17 ' - 3 " 8'-6" 5' - 6 " 11'-9" 13 ' - 8 " 8'-1"2' - 7 " 3'-3"2'-5" 4' - 6 " 12 ' - 3 " 7'-1" 14'-4" 13 ' - 1 1 " W H 43'-9" 16'-1"6'-2"12'-5"9'-1" 7'-10"8'-3"1'-11"2'-3"4'-6"3'-7"4'-9" 34 ' - 4 " 2' - 1 1 " 6' - 2 " 4' - 1 1 " 8' - 6 " 7' - 4 " 3' - 3 " 3' - 5 " 4' - 0 " 8'-11" 6'-4"4'-1"4'-10" 34 ' - 4 " 19 ' - 1 0 " 14 ' - 6 " 4' - 0 " 12 ' - 0 " 3' - 3 " (E ) F . P . 3' - 1 0 " 4'-4" 15'-3" 13 ' - 6 " 8'-1"2' - 7 " 3'-3" 7' - 7 " 15'-4" 6' 7' - 7 " 7'-1" 8' - 9 " SD CM SD SD 6'-0" (E ) 5 : 1 2 (E ) 5 : 1 2 (E ) 5 : 1 2 (E ) 5 : 1 2 (E) 5:12 (E) 5:12 (E) 5:12 (E) 5:12 (E) 5:12 PR O P E R T Y L I N E 1 1 9 . 8 1 ' 0'-2" 5'-10" 5'-0" (E) ASPHALT SHINGLES (E) ASPHALT SHINGLES 3'-7" UP UPUP UP UP UP UP 7' - 1 1 " 2' - 1 1 " 11'-9" REVISION(S) 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M 24-107 MAY 2024 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 1 10/14/2024 11/05/2024 1.1 1/4"=1'0" WALL LEGEND EX.2X4 STUDS @ 16" O.C. DEMOLISHED WALLS NOTE: QUALITY INSULATION INSTALLATION REQUIRED (E) /DEMO FLOOR PLAN & (E) ROOF PLAN 1311 N Towner 12/12/2024 ROOF LEGEND Proposed House Remodel Floor Plan Scale: 1/4"=1'0" 5'-11" 12'-2" 3' - 4 " (E) Living Room 292 S.F. (E) Entrance 41 S.F. (E) Romdeled Dining Room 194 S.F. (E) Remodeled Kitchen 147 S.F. (E) Bedroom #1 161 S.F. (E) M. Bedroom 200 S.F. (E ) C l o s e t (E) Linen (E) Remodeled Laundry 33 S.F. (Ex) W.I.C. 46 S.F.(Ex) M.BATH 116 S.F. (E) Bath. 62 S.F. (E) Hallway 53 S.F. (E) Linen (N ) C l o s e t 12 . 5 S . F . 9'-1" 4'-6" 2' - 1 1 " 7' - 4 " 5'-10" 4'-4" (E) Landing 6' - 8 " SD SD (E) F.P. PR O P E R T Y L I N E 1 1 9 . 8 1 ' 10'-1" 16'-0"6'-9" 43'-9" 8' - 3 " 11 ' - 1 " 3' - 1 0 " 3' - 1 " 14 ' - 4 " 6' - 1 1 " 3' - 1 " 4' - 0 " 7' - 1 " 5' - 1 0 " 42 ' - 4 " 43'-9" 16'-1"6'-2"12'-5" 7'-10"8'-3"1'-11"2'-3"2'-1"3'-7"4'-4"4'-9" 42 ' - 4 " 17 ' - 1 0 " 6' - 2 " 7' - 5 " 13 ' - 5 " 3' - 3 " 3' - 5 " 4' - 0 " 6'-4"4'-0"4'-11" 8'-11" 7' - 7 " 13 ' - 1 1 " (E) Landing 15'-4" 6' 7' - 7 " 11'-9" 13 ' - 8 " 19 ' - 2 " 6'-2" 15'-3" 3' - 3 " 3'-4" 7'-1" 8' - 9 " 8' - 0 " SD CM 5' - 6 " 6'-1" 14'-4" 7'-1" UP UP 2' REF. (N) ISLAND 4' 6' 3' 4' - 6 " 4' - 6 " 16 ' - 6 " 11'-5" 17 ' - 3 " 5"3' NEW TANK-LESS WATER HEATER LOCATION REVISION(S) 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M 24-107 MAY 2024 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 1 10/14/2024 11/05/2024 PROPOSED FLOOR PLAN 2.0 1/4"=1'0" FLOOR NOTES NO.REMARKS SMOKE DETECTOR SHALL BE HOUSE INTERCONNECTED HARD-WIRED WITH WITH BATTERY BACKUP AND SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. SINGLE- OR MULTIPLE-STATION SMOKE ALARMS SHALL BE INSTALLED AND MAINTAINED IN GROUPS R-2, R-2.1, R-2.2, R-3, R-3.1 AND R-4 REGARDLESS OF OCCUPANT LOAD AT ALL OF THE FOLLOWING LOCATIONS: 1. ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. 2. IN EACH ROOM USED FOR SLEEPING PURPOSES. 3. IN EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. 4. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL, PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. 5. IN A GROUP R-3.1 OCCUPANCIES, IN ADDITION TO THE ABOVE, SMOKE ALARMS SHALL BE PROVIDED THROUGHOUT THE HABITABLE AREAS OF THE DWELLING UNIT EXCEPT KITCHENS. SEE SECTION 907.2.11.8FOR SPECIFIC LOCATION REQUIREMENTS.(CBC 907.2.10.2) CARBON MONOXIDE ALARMS REQUIRED IN DWELLINGS WITH FUEL-BURNING APPLIANCES OR WITH ATTACHED GARAGES; SAME REQUIREMENT FOR ADDITIONS / ALTERATIONS SHALL BE LOCATED OUTSIDE EACH SLEEPING AREA AND ON EVERY LEVEL. CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP SHELF AND POLE ATTIC FURNACES AND COOLING EQUIPMENT SHALL COMPLY WITH THE FOLLOWING: 1. HAVE A 30"X30" MINIMUM ATTIC ACCESS OPENING WITHIN 20' OF THE EQUIPMENT. 2. HAVE A CONTINUOUS 24" WIDE SOLID FLOOR ACCESS PATH THERETO. 3. HAVE A 30" DEEP WORKING PLATFORM AT CONTROL SIDES. 4. HAVE AN ELECTRIC OUTLET AND A LIGHT FIXTURE (CONTROLLED BY SWITCH AT THE FURNACE PROVIDE MOIST-STOP FLASHING AROUND ALL WINDOWS, DOORS & OTHER OPENINGS. ALL WINDOWS SHALL BE DOUBLE PANEL LOW "E" WINDOWS. ALL NEW GLAZED OPENING SHALL BE LABELED INDICATING A CERTIFIED U VALUE. DEX-O-TEX (ESR-1757) DECK COVERING SAFETY GLAZING (TEMPERED). GLAZING IN HAZARDOUS LOCATIONS AS DEFINED IN CBC SECTION 2406.4 SHALL BE TEMPERED GLASS, INCLUDING: 1. SWINGING AND SLIDING DOORS. 2. SHOWER AND TUB ENCLOSURES, INCLUDING EXTERIOR WINDOW GLAZING. 3. GLAZING WITHIN 24" OF DOORS AND WITHIN 60" OF WALKING SURFACE. LANDING: 1. LANDING AT A DOOR SHALL HAVE MIN. OF 36" LENGTH IN THE DIRECTION OF TRAVEL AND A MAXIMUM SLOPE OF ANY LANDING SHALL NOT EXCEED 1/4 INCH PER FOOT. 2. LANDING SHALL BE PROVIDED AT THE TOP AND BOTTOM OF STAIRWAYS, EXCEPT FOR TOP OF INTERIOR FLIGHT OF STAIRS AND STAIRS IN AN ENCLOSED GARAGE. 3. ENTRY AND EXIT DOORS MUST OPEN OVER A LANDING NOT MORE THAN 1.5" BELOW THE THRESHOLD. EXCEPTION, PROVIDED THAT THE DOOR DOES NOT SWING OVER THE LANDING, LANDING SHALL BE NOT MORE THAN 7.75" BELOW THE THRESHOLD 4. STORM AND SCREEN DOORS ARE PERMITTED TO SWING OVER ALL EXTERIOR STAIRS AND LANDING. STAIRS, GUARDRAILS AND HANDRAILS (SEE DETAIL -----) 1. ALL GUARDRAILS SHALL BE 42" IN HEIGHT WITH LESS THAN 4 INCHES SPACING OPENING BETWEEN RAILS. 2. HEIGHT OF HANDRAILS SHALL BE BETWEEN THE HEIGHT OF 34"-38" MEASURED VERTICALLY FROM THE LEADING EDGE OF THE STAIR NOSING TREAD. 3. HANDGRIP PORTION OF HANDRAIL SHALL NOT BE LESS THAN 1.25" AND NO MORE THAN 2" CROSS-SECTIONAL DIMENSION HAVING A SMOOTH SURFACE WITH NO SHARP CORNERS. 4. MAXIMUM RISE OF STAIRS IS 7.75" AND MINIMUM RUN 10". 30"X60" TUB. INSTALL PER MANUFACTURER SPECS. WITH TILE SURROUND. UNDERLAYMENT HARDI-BACKER (NER 405) or EQUAL. (SELECTED BY OWNER) WALL COVERING SHALL BE TILE OR OF EQUALLY APPROVED MATERIAL 72" ABOVE DRAIN INLET. CEMENT, FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. FLUSH VOLUMES FOR LOW-CONSUMPTION AND WATER-SAVER WATER CLOSET SHALL BE PROVIDED WITH A MAX. OF 1.28 GALLONS PER FLUSH. LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS PER MINUTE. KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE. SHOWER HEAD FLOW SHALL NOT EXCEED 1.8 GALLON PER MINUTE SHOWERS AND TUB-SHOWERS SHALL BE PROVIDED W/ INDIVIDUAL CONTROLS OF THE PRESSURE BALANCE TYPE OR THE THERMOSTATIC MIXING VALVE. (SEE DETAIL 1, SHEET AD) FIBERGLASS TUB/SHOWER SHALL BE ICC or IAPMO LISTED. (SEE DETAIL 1, SHEET AD FOR ADDITIONAL CURB REQUIREMENTS) 3/4" HOSE BIB W/ ANTI-SIPHON DEVICE PROVIDE ONE-HOUR FIRE RESISTANT DOOR TIGHT FITTING, SELF-CLOSING AND SELF-LATCHING, SOLID WOOD OR SOLID OR HONEYCOMB CORE STEEL NOT LESS THAN 1 3/8 INCHES THICK, OR HAVE A MINIMUM FIRE PROTECTION RATING OF 20 MINUTES. (R302.5.1) PROVIDE FIRE RESISTANT 5/8" TYPE " X " GYPSUM BOARD TO GARAGE SIDE OF WALL FROM FLOOR TO ROOF SHEATHING AT ALL WALLS AND CEILING BETWEEN "U" OCCUPANCY (GARAGE) & "R" OCCUPANCY. -ALL OUTLETS IN FIREWALL SHALL HAVE PUTTY PADS -THE DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL BE CONSTRUCTED OF SHEET STEEL NOT LESS THAN 0.019 INCHES IN THICKNESS AND SHALL NOT HAVE OPENINGS INTO THE GARAGE. 5/8" TYPE "X" DRYWALL UNDER STAIRS, WALLS, CEILING, CLOSET AND BATHROOM. LINEN CLOSET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 NO.REMARKS BATHROOM EXHAUST FANS EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING: 1. FANS SHALL BE ENERGY STAR COMPLAINT AND DUCTED TO TERMINATE OUTSIDE THE BUILDING 2. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL. a. HUMIDITY CONTROL SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE LESS THAN OR EQUAL TO 50% TO A MAXIMUM OF 80%.A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. b. A HUMIDITY CONTROL MAY BE SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL (i.e. BUILT-IN) WASHER SPACE: PROVIDE WASTE DRAIN, HOT AND COLD WATER. CONDENSATE WASTE SHALL BE COLLECTED AND DISCHARGED TO AN APPROVED PLUMBING FIXTURE OR DISPOSAL AREA. CONDENSATE OR WASTEWATER SHALL NOT DRAIN OVER A PUBLIC WAY.(310.1) DRYER SPACE: PROVIDE 4" DIA. VENT TO OUTSIDE AIR. 14' MAX. LENGTH W/ 2 BENDS AND FIRE PROTECTED WHEN IT IS GOING THROUGH A WALL.DRYER SPACE: PROVIDE 4" DIA. VENT TO OUTSIDE AIR. 14' MAX. LENGTH W/ 2 BENDS AND FIRE PROTECTED WHEN IT IS GOING THROUGH A WALL. 30" x 30" ATTIC ACCESS. WITH ANY ATTIC AREA HAVING A CLEAR HEIGHT OF OVER 30" MIN. CLEAR HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT OR ABOVE THE ACCESS OPENING. VERIFY LOCATION ON SITE. GAS STOVE W/ KITCHEN EXHAUST HOOD (PER 2022 CEC TABLE 150.0-G) MANUF.: BROAN ELITE, MODEL: EW4830SS, 280 CFM, HVI CERTIFIED, 1.5 SONE , EXHAUST DUCT THROUGH ROOF/WALL (SEE DETAIL K1 SHEET 2.1) INDOOR AIR QUALITY FAN CFM MIN. PER T24, SOUND RATING A MAXIMUM OF 1 SONE IT SHALL BE CONTINUOUS AND DUCTED TO TERMINATE OUTSIDE THE BUILDING. MANUF:BROAN, MODEL: FIN-180B-HW 40 GALLON, HEAT PUMP WATER HEATER . MANUF: RHEEM, OR EQ. WHOLE HOUSE FAN CFM PER T24 REQUIREMENTS MANUF: QUITE COOL, OR EQ. 22 23 24 25 26 27 29 30 TABLE 150.0-G KITCHEN RANGE HOOD AIRFLOW RATES (CFM) AND ASTM E3087 CAPTURE EFFICIENCY (CE) RATING ACCORDING TO DWELLING UNIT FLOOR AREAS AND KITCHEN RANGE FUEL TYPE DWELLING UNIT FLOOR AREA (ft²) HOOD OVER ELECTRIC RANGE HOOD OVER NATURAL GAS RANGE >1500 50% CE OR 110 CFM 70% CE OR 180 CFM >1000-1500 50% CE OR 110 CFM 80% CE OR 250 CFM 750-1000 50% CE OR 130 CFM 85% CE OR 280 CFM <750 65% CE OR 160 CFM 85% CE OR 280 CFM 23 WALL LEGEND NEW 2X4 STUDS @ 16" O.C. NEW 2X4 STUDS @ 16" O.C. w/ 2X8 BLK'G FOR AGE-IN-PLACE ELEMENTS EX.2X4 STUDS @ 16" O.C. EX. 2X4 STUDS @ 16" O.C. w/ 2X8 BLK'G FOR AGE-IN-PLACE ELEMENTS NOTE: QUALITY INSULATION INSTALLATION REQUIRED 1 2 1 1 22 22 13 26 24 22 2 1311 N Towner 12/12/2024 8' - 0 " C L G . TY P I C A L Ceiling 15 " MA X . 7' - 0 " M I N . CL E A R CEILING MOUNTED FIXTURES ELECTRICAL OUTLETS48 " A. F . F . ELECTRICAL LIGHT SWITH SCALE: NONE ELECTRICAL FIXTURE PLACEMENTE1 DOORBELL BUTTON OR CONTROL 48 " A. F . F . SCALE: NONE TYPICAL KITCHEN APPLIANCE BRANCH CIRCUITSE2 HERS FEATURE SUMMARY HERS FEATURE SUMMARY ELECTRICAL RANGE (240V)50 AMPERES KITCHEN COUNTER TOP SMALL APPLIANCE BRANCH CIRCUIT (120V)20 AMPERES COUNTER-MOUNTED ELECTRIC COOKING UINT (240V)30 AMPERES DISHWASHER (120V)15-20 AMPERES GARBAGE DISPOSAL (120V)15 AMPERES WALL-MOUNTED ELECTRIC OVEN (240V)30-40 AMPERES MICROWAVE (120V)20 AMPERES TRASH COMPACTOR (120V)15 AMPERES 2' 2'2'-6"2' 2'4' 2' 2' 4' 4' 2'-6" RECEPTACLE OUTLETS ARE REQUIRED AT EACH COUNTER SPACE WIDER THAN 12 IN. SPACED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 IN. FROM A RECEPTACLE. ISLAND AND PENINSULAR TYPE COUNTER TOPS ARE REQUIRED TO HAVE ONE RECEPTACLE FOR EACH 4 FEET OF COUNTER-TOP. COUNTER-TOP OUTLETS ARE REQUIRED TO BE GROUND FAULT CIRCUIT INTERRUPTED (GFCI) PROTECTED. OUTLETS IN THE KITCHEN ARE REQUIRED TO BE DIVIDED BETWEEN TWO 20 AMP. CIRCUITS. PRIMARY TASK LIGHTING IN THE KITCHEN MUST BE FLUORESCENT, HOWEVER; SECONDARY TASK LIGHTING MAY BE INCANDESCENT. DISHWASHER/ GARBAGE DISPOSAL CIRCUITS UNDER SINK SINK PR I M A R Y FL U O R E S C E N T LI G H T I N G SEPARATE CIRCUIT REQUIRED FOR EACH OF THE ABOVE APPLIANCES AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI 240V SD Proposed House Remodel Elec. Plan Scale: 1/4"=1'0" SD CM SD WP GFI WP GFI F F UP UP REF. R R R R R PE N D A N T L I G H T S RR RR RR 3 3 240V 240V AFCI GFCI AFCI GFCI R R 240V AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI 3 3 F AFCI GFCI 3 3 AFCI AFCI AFCI AFCI AFCI NEW TANK-LESS WATER HEATER LOCATION AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI GFCI REVISION(S) 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M 24-107 MAY 2024 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 1 10/14/2024 11/05/2024 PROPOSED ELECTRICAL PLAN 2.1 1/4"=1'0" RECESSED LIGHT MOUNTED WALL LIGHT SWITCH R 208/240V OUTLET CEILING FAN F FAN SWITCH D DIMMER SWITCH 3 3-WAY SWITCH AFCI GFI WP GFI SD CD CARBON MONOXIDE DETECTOR VS VACANCY SENSOR SWITCH OS OCCUPANCY SENSOR SWITCH MS PC EXHAUST FAN W/ LITE MIN. 50 CFM ENERGY STAR WITH HUMIDISTAT SMOKE DETECTOR IN THE HOUSE WIRE WITH BATTERY BACK-UP CLG. MOUNTED LIGHT FIXTURE 110V OUTLET ARC FAULT CIRCUIT INTERRUPTOR 110V OUTLET GROUND FAULT CIRCUIT INTERRUPTOR 110V OUTLET WEATHER PROOFED GROUND FAULT CIRCUIT INTERRUPTOR PHOTOCONTROL CELL / MOTION SENSOR COMBINATION INDOOR AIR QUALITY FAN IAQ FAN SWITCH LIGHT SWITCH LABEL SHALL STATE THE FOLLOWING: "THIS SWITCH CONTROLS THE INDOOR AIR QUALITY OF THE DWELLING UNIT AND SHALL REMAIN ON WHILE OCCUPIED." IAQ ELECTRICAL NOTES · LIGHTING SHALL COMPLY WITH THE APPLICABLE HIGH EFFICACY · REQUIREMENT OF THE CALIFORNIA TITLE 24 PART 6 SECTION 150. · PROVIDE FLUORESCENT OR LED LIGHTING IN BATHROOMS WITH AT LEAST 40 LUMENS PER WATT. · PROVIDE A DEDICATED 20 Amp CIRCUIT FOR THE BATHROOM. · PROVIDE A MINIMUM OF TWO 20 Amp SMALL APPLIANCE CIRCUITS SERVING THE COUNTERS IN THE KITCHEN. · PROVIDE GFCI AND AFCI PROTECTION FOR EXTERIOR OUTLET, ALL COUNTER OUTLETS KITCHEN AND BATH OF ALL SINKS & AT LAUNDRY ROOM. · IF 2 OR MORE FIXTURES ARE PROVIDED IN BATHROOM, INCLUDING AREAS SEPARATED BY PRIVACY DOOR, ONE SHALL BE A FLUORESCENT OR LED WHICH IS SWITCHED FIRST UPON ENTERING AREA or IF ONE COMPARTMENT BATHROOM THEN ONE FLUORESCENT FIXTURE IS REQUIRED. · CEC 230.24(A). POWER LINE - 8' CLEARANCE BETWEEN THE SERVICE WIRE AND THE ROOF, IF THE SLOPE SLOPE IS LESS THAT 4"/12". THIS 8' CLEARANCE INCLUDES THE PATIO TRELLIS. · ELECTRICIAN SHALL PROVIDE GREEN SHEET/LINE DIAGRAM AT TIME OF PERMINT ISSUANCE. · AT LEAST THE SWITCHED CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE ROOM; IN BATHROOMS, HALLWAYS, STAIRS, GARAGES AND OUTDOOR ENTRNACES OR EXISTS. · A RECEPTICAL SHALL BE INSTALLED IN HALLWAY 10 FEET IN LENGHT OR GREATER. · ELECTRIC EXHAUST FAN CAPABLE OF PROVIDING 5 COMPLETE AIR CHANGE EVERY FIVE MINUTES · ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 & 20 AMPERE OUTLETS INSTALLED IN BEDROOMS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S) · HIGH EFFICACY LIGHTING (E.G. LED FLUORESCENT) IN LAUNDRY ROOM AND BATHROOM OR LIGHTING SHALL BE CONTROLLED BY MANUAL ON VACANCY SENSORS. · HIGH EFFICACY LIGHTING (E.G. LED FLUORESCENT) IN HALLWAYS, DINING ROOM, FAMILY ROOM, , LIVING ROOM , NOOK AND BEDROOMS - OR LIGHTING SHALL BE CONTROLLED BY MANUAL-ON OCCUPANT SENSORS OR DIMMER SWITCHES. · OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY OR MUST BE CONTROLLED BY A MOTION SENSORS OR DIMMER SWITCHES. · RECEPTACLE OUTLETS SHALL BE SPACED @ 12" O.C. MAX. AND SHALL BE LOCATED WITHIN 6' OF DOOR OPENINGS. ALSO, EVERY 2' OR WIDER OF WALLS. OUTLETS ALSO REQUIRED FOR COUNTER TOPS @ 4' O.C. AND WITHIN 2' OF ENDS OR COUNTERS. · ALL ROOMS EXCEPT BATHROOMS & GARAGES REQUIRE TO BE ARC FAULT PROTECTED · HIGH EFFICACY LUMINAIRES MUST BE PIN BASED. · NON-HIGH EFFICACY LUMINAIRES MUST BE SWITCHED ON A SEPERATE CIRCUIT FROM HIGH EFFICACY LUMINARIES. · VACANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 30 MINUTE MAXIMUM TIMER AND BE MICROWAVE/ ULTRASONIC OR PASSIVE INFRA-RED TYPE. · NO CORD-CONNECTED, CHAIN, CABLE, CORD-SUSPENDED, LIGHTING TRACK, PENDANT, LUMINAIRES OR CEILING-SUSPENDED FANS SHALL BE LOCATED WITHIN 3' HORIZONTALLY AND 8' VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER STALL. LUMINAIRES LOCATED IN THIS ZONE SHALL BE LISTED FOR DAMP AREAS OR LISTED FOR WET LOCATIONS WEHERE SUBJECT TO SHOWER SPRAY. · CONDUCTORS NORMALLY USED TO CARRY CURRENT SHALL BE OF COPPER. FOR ALUMINUM AND COPPER-CLAD ALUMINUM #6 AWG AND LARGER, SEE SEC. 31-15. EXCEPTION: ALUMINUM CONDUCTORS SMALLER THAN #6 AWG MAY BE USED PROVIDED THE METHOD OF CONNECTION IS APPROVED IN ADVANCE BY THE BUILDING OFFICIAL AND THE INSTALLATION IS MADE UNDER CONTINUOUS SPECIAL INSPECTION. · EVERY FIXED APPLIANCE, SUCH AS FOOD WASTE GRINDERS, DISHWASHERS, WASHING MACHINES, DRYERS, LAUNDRY TRAY LOCATIONS, BUILT-IN REFRIGERATORS OR FREZZERS, FURNACES, AC, BUILT-IN HEATERS OR ANY OTHER FIXED APLIANCE WITH A MOTOR OF 1/4 H.P. OR LARGER SHALL BE ON A SEPARATE 20 AMP. BRANCH CIRCUIT. · AT LEAST ONE RECEPTICAL AT GRADE LEVEL SHALL BE INSTALLED IN BOTH THE FRONT AND BACK OF EACH DWELLING KUNIT. (210.52 CEC) ELECTRICAL KEY NOTES GFIC OUTLET ALL KITCHEN, BATH, GARAGE, AND EXTERIOR. FLUORESCENT OR LED LIGHT FIXTURE 40 LUMENS PER WATT IN BATHROOM, KITCHEN, AND LAUNDRY E1 E2 ELECTRICAL SYMBOLS AGING-IN-PLACE DESIGN & FALL PREVENTION NOTES 1. GRAB BAR REINFORCEMENT FOR THE BATHROOM IDENTIFIED ON THE FLOOR PLANS FOR “AGING-IN-PLACE AND FALL PREVENTION” COMPLIANCE SHALL BE INSTALLED AT THE WATER CLOSET, SHOWER, BATHTUB AND BATHTUB/SHOWER AS STATED BELOW. 2. WATER CLOSET REINFORCEMENT: a. REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. b. FOR WATER CLOSET NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, REINFORCEMENT SHALL BE INSTALLED FOR FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BARS ADJACENT TO THE WATER CLOSET APPROVED BY THE ENFORCING AGENCY. c. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. 3. SHOWER REINFORCEMENT: a. REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. b. FOR SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS, REINFORCEMENT SHALL BE INSTALLED FOR FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. c. WHERE FACTORY-INSTALLED GRAB BARS OR FACTORY-INSTALLED REINFORCEMENT IS PROVIDED IN PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS, REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING. 4. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT: a. REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. b. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE OF THE REINFORCEMENT LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. c. FOR BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT, REINFORCEMENT SHALL BE INSTALLED FOR FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. d. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS INSTALLED ON CONCRETE SLAB FLOORS. REINFORCEMENT MATERIAL AND DIMENSIONS 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. 3. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 AND 39-¼ INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. DOCUMENTATION 1. INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATIONS OF THE GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. ELECTRICAL 1. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. 2. EXCEPTIONS TO THE INSTALLATION HEIGHTS: a. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. b. WALL RECEPTACLE OUTLETS WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR,SUCH AS A WINDOW, IS LESS THAN 15 INCHES. DOORBELL 1. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. 2. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. INTERIOR DOORS (EFFECTIVE JULY 1, 2024) 1. DOORWAYS FOR THE BATHROOM AND BEDROOM IDENTIFIED ON THE FLOOR PLANS FOR “AGING-IN-PLACE AND FALL PREVENTION” COMPLIANCE SHALL PROVIDE A NET CLEAR OPENING OF NOT LESS THAN 32 INCHES, MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED POSITION. E1 E1 E1 WALL LEGEND NEW 2X4 STUDS @ 16" O.C. NEW 2X4 STUDS @ 16" O.C. w/ 2X8 BLK'G FOR AGE-IN-PLACE ELEMENTS EX.2X4 STUDS @ 16" O.C. EX. 2X4 STUDS @ 16" O.C. w/ 2X8 BLK'G FOR AGE-IN-PLACE ELEMENTS NOTE: QUALITY INSULATION INSTALLATION REQUIRED E1 E1 E1 E1 E1 E1 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2E2 E2 E2 E5 2 1311 N Towner 12/12/2024 REVISION(S) 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M 24-107 MAY 2024 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 1 10/14/2024 11/05/2024 N.T.S. TITLE PAGE T1 VICINITY MAPLEGAL DESCRIPTION SHEET INDEX GENERAL NOTES 1311 N Towner St., Santa Ana, CA 92706 PARCEL MAP SCOPE OF WORK ASSESSOR'S ID. NUMBER: 405-301-09 TR #1064 , BLOCK 301 AND LOT #09 EX RESIDENCE: 1 YEAR BUILT: 1949 NUMBER OF STORIES: 1 TYPE OF CONSTRUCTION: V-B (E) M.F.D. SPRINKLERED: NO BUILDING HEIGHT:17'-5" PROJECT SUMMARY DESIGNER / AYMAN IVAN SHMEIT ENGINEER: MID-CITIES ENGINEERING 9744 MAPLE ST. #101 BELLFLOWER, CA 90706 TEL: (562) 866-3625 WWW.MIDCITIESENGINEERING.COM OWNER: DEAN HALL ADDRESS: 1311 N TOWNER ST., SANTA ANA, CA 92706 PHONE: (714) 864-1632 EMAIL: DEAN@CASAREVIVAL.COM CODES 1. THE GOVERNING CODES FOR THIS PROJECT ARE: 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECH. CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE -ALL WORK SHALL CONFORM TO: CITY OF SANTA ANA - ZONING AND DEPARTMENT OF BUILDING AND SAFETY. ZONING:R1 LOT AREA: 7,022 S.F. DIRECTORY OVERALL TOTAL HABITABLE 1,504 S.F. TITLE PAGE EXISTING SITE PLAN EXISTING /DEMOLISHED FLOOR PLAN & ROOF PLAN PROPOSED FLOOR PLAN PROPOSED ELECTRICAL PLAN TI 1.0 1.1 2.0 2.1 STRUCTURAL TITLE PAGE FOUNDATION & ROOF FRAMING PLAN STRUCTURAL NOTES STRUCTURAL NOTES S S1 SN1 SN2 1. OBTAIN SEPARATE APPLICATION FOR THE FOLLOWING ITEMS: a. RETAINING WALLS OR BLOCK FENCE WALLS b. GRADING WORK c. SWIMMING POOLS d. A SEPARATE STRUCTURE e. SHORING f. DEMOLITION 2. THE PERMIT APPLICATION MUST BE SIGNED BY THE PROPERTY OWNER, OR LICENSED CONTRACTOR, OR AUTHORIZED AGENT AT THE TIME THE PERMIT IS TO BE ISSUED: a. FOR OWNER-BUILDER PERMITS: OWNER’S SIGNATURE CAN BE VERIFIED WITH OWNER'S DRIVER LICENSE. OWNER’S REPRESENTATIVES MUST PRESENT OWNER’S APPROVAL WITH A NOTARIZED LETTER FROM THE OWNER. b. FOR CONTRACTOR BUILDING PERMITS: PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE CONTRACTOR SHALL HAVE THE FOLLOWING: 1) NOTARIZED LETTER OF AUTHORIZATION FOR AGENTS. 2) CERTIFICATE OF WORKERS COMPENSATION INSURANCE MADE OUT TO THE CONTRACTORS STATE LICENSE BOARD. 3) COPY OF CONTRACTORS STATE LICENSE OR POCKET ID. 4) COPY OF CITY BUSINESS TAX REGISTRATION CERTIFICATE OR A NEWLY PAID RECEIPT FOR ONE. EACH SHEET OF THE PLANS SHALL BEAR THE SIGNATURES, REGISTRATION OF AN ARCHITECT OR ENGINEER REGISTERED IN THE STATE OF CALIFORNIA. THE FINAL SET OF PLANS MUST BE STAMPED BY ALL CITY AGENCIES 3. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS THE WORK ON THE SITE AUTHORIZED BY SUCH PERMIT IS COMMENCED WITHIN 180 DAYS AFTER ITS ISSUANCE, OR IF THE WORK AUTHORIZED ON THE SITE BY SUCH PERMIT IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AFTER THE TIME THE WORK IS COMMENCED. THE BUILDING OFFICIAL IS AUTHORIZED TO GRANT ONE EXTENSION OF TIME FOR PERIOD OF NOT MORE THAN 180 DAYS. THE EXTENSION SHALL BE REQUESTED IN WRITING AND JUSTIFIABLE CAUSE DEMONSTRATED. EXTENSIONS SHALL ONLY BE GRANTED PRIOR TO THE EXPIRATION OF A PERMIT(SECTION 105.5) 4. THE CONTRACTOR SHALL ALL TIMES KEEP THE PREMISES FREE FROM ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS EMPLOYEES OR WORK, AND AT THE COMPLETION OF THE WORK, HE SHALL REMOVE ALL HIS RUBBISH FROM AND ABOUT THE BUILDING AND ALL HIS TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND SHALL LEAVE HIS WORK BROOM CLEAN OR ITS EQUIVALENT, UNLESS MORE EXACTLY SPECIFIED. IN CASE OF DISPUTE, THE OWNER MAY REMOVE THE RUBBISH AND CHARGE THE COST TO THE CONTRACTOR. 5. THESE DRAWINGS DO NOT PURPORT TO SHOW ALL EXISTING (E) CONDITIONS, EXISTING ITEMS TO BE REMOVED, INTERFACE BETWEEN EXISTING AND NEW. FURTHER, MANY EXISTING CONDITIONS WERE BASED ON ORIGINAL AND/ OR "AS-BUILT" DRAWINGS GENERATED FROM NONDESTRUCTIVE FIELD SURVEYS. ALTHOUGH THE BASIC INFORMATION IS ACCURATE, ACTUAL SITE CONDITIONS MAY VARY. 6. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER AND WITH INFORMATION FURNISHED BY THE OWNER AND SHALL AT ONCE REPORT TO THE ARCHITECT/ENGINEER ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED. THE CONTRACTOR SHALL NOT BE LIABLE TO THE OWNER OR ARCHITECT/ENGINEER FOR DAMAGE RESULTING FROM ERRORS, INCONSISTENCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS UNLESS THE CONTRACTOR RECOGNIZED SUCH ERROR, INCONSISTENCY OR OMISSION AND KNOWINGLY FAILED TO REPORT IT TO THE ARCHITECT/ENGINEER. IF THE CONTRACTOR PERFORMS ANY CONSTRUCTION ACTIVITY KNOWING IT INVOLVES A RECOGNIZED ERROR, INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT SUCH NOTICE TO THE ARCHITECT/ENGINEER, THE CONTRACTOR SHALL ASSUME APPROPRIATE RESPONSIBILITY FOR SUCH PERFORMANCE AND SHALL BEAR AN APPROPRIATE AMOUNT OF THE ATTRIBUTABLE COSTS FOR CORRECTION. 7. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS AND SHALL CAREFULLY COMPARE SUCH FIELD MEASUREMENTS AND CONDITIONS AND OTHER INFORMATION KNOWN TO THE CONTRACTOR WITH THE CONTRACT DOCUMENTS BEFORE COMMENCING ACTIVITIES. ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE ARCHITECT/ENGINEER AT ONCE. 8. THE CONTRACTOR WARRANTS TO THE OWNER AND ARCHITECT/ENGINEER THAT MATERIALS AND EQUIPMENT FURNISHED UNDER THE CONTRACT WILL BE OF GOOD QUALITY AND NEW UNLESS OTHERWISE REQUIRED OR PERMITTED BY THE CONTRACT DOCUMENTS, THAT THE WORK WILL BE FREE FROM DEFECTS NOT INHERENT IN THE QUALITY REQUIRED OR PERMITTED, AND THAT THE WORK WILL CONFORM WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. WORK NOT CONFORMING TO THESE REQUIREMENTS, INCLUDING SUBSTITUTIONS NOT PROPERLY APPROVED AND AUTHORIZED, MAY BE CONSIDERED DEFECTIVE. THE CONTRACTOR'S WARRANTY EXCLUDES REMEDY FOR DAMAGE OR DEFECT CAUSED BY ABUSE, MODIFICATIONS NOT EXECUTED BY THE CONTRACTOR, IMPROPER OPERATION, OR NORMAL WEAR AND TEAR UNDER NORMAL USAGE. IF REQUIRED BY THE ARCHITECT, THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF MATERIALS AND EQUIPMENT. 9. THE CONTRACTOR SHALL EMPLOY A COMPETENT SUPERINTENDENT AND NECESSARY ASSISTANTS WHO SHALL BE IN ATTENDANCE AT THE PROJECT SITE DURING PERFORMANCE OF THE WORK. THE SUPERINTENDENT SHALL REPRESENT THE CONTRACTOR, AND COMMUNICATIONS GIVEN TO THE SUPERINTENDENT SHALL BE AS BINDING AS IF GIVEN TO THE CONTRACTOR. IMPORTANT COMMUNICATIONS SHALL BE CONFIRMED IN WRITING. OTHER COMMUNICATIONS SHALL BE SIMILARLY CONFIRMED ON WRITTEN REQUEST IN EACH CASE. 10. CONTRACTORS AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOTE BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE DESIGNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 11. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT 1-800-422-4133, 48 HOURS IN ADVANCE OF COMMENCEMENT OF CONSTRUCTION, FOR EXISTING UTILITY LOCATIONS. ONLY WHEN WORK IS DONE OFF SITE IN THE PUBLIC RIGHT-OF-WAY. 12. THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING AT A SLOPE OF NOT LESS THAN ONE UNIT VERTICAL IN 20 UNITS HORIZONTAL (5%) FOR A MINIMUM DISTANCE OF 10 FEET MEASURED PERPENDICULAR TO THE FACE OF THE WALL(R401.3) 13. SITE MEASUREMENTS OF THE PROPERTY LINE BOUNDARIES ARE AN ASSUMPTION AND ARE PRESENTED AS IS, WITH NO GUARANTEE OF ACCURACY OR COMPLETENESS. INFORMATION USED HERE IS CREATED FROM PUBLIC RECORDS AND EXISTING MAP SOURCES, NOT DIRECTLY FROM FIELD SURVEYS. THE PRECISE LOCATION OF PROPERTY BOUNDARIES MUST BE DETERMINED BY A LAND SURVEYOR REGISTERED TO PRACTICE IN THE STATE OF CALIFORNIA. PRIOR TO ANY COMMENCEMENT OF WORK IT IS THE OWNER(S)/CONTRACTOR RESPONSIBILITY TO VERIFY ALL PROPERTY BOUNDARIES THROUGH THE SERVICES OF A REGISTERED LAND SURVEYOR. 14. DRAFTSTOPS SHALL BE INSTALLED WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, SO THAT THE AREA OF CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET AND IS DIVIDED INTO APPROXIMATELY EQUAL AREAS. DRAFTSTOPPING MATERIAL SHALL BE AS SPECIFIED IN SECTION R302.12. 15. FIREBLOCKING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.11: A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS AT THE CEILING AND FLOOR LEVEL, AND AT MAXIMUM 10-FOOT HORIZONTAL INTERVALS. BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED NONRIGID MATERIALS SHALL BE PERMITTED FOR COMPLIANCE WITH THE 10-FOOT HORIZONTAL FIREBLOCKING IN WALLS CONSTRUCTED USING PARALLEL ROWS OF STUDS OR STAGGERED STUDS B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. D. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003.19 16. FIREBLOCKING MATERIALS SHALL CONSIST OF ONE OF THE FOLLOWING (R302.11.1) A. 2-INCH NOMINAL LUMBER B. TWO THICKNESSES OF 1-INCH NOMINAL LUMBER WITH BROKEN LAP JOINTS. C. ONE THICKNESS OF 23/32INCH WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY 23/32 INCH WOOD STRUCTURAL PANELS. D. ONE THICKNESS OF 3/4-INCH PARTICLE BOARD WITH JOINTS BACKED BY 3/4 INCH PARTICLE BOARD, 1/2 INCH GYPSUM BOARD OR 1/4 INCH CEMENT-BASED MILLBOARD. E. BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. DEFERRED SUBMITTAL 1311 (S.F.D ) OCCUPANCY: R-3/U - (E) MAIN DWELLING 1,504 S.F. - (E) GARAGE 422 S.F. - (E) BUILDING 216 S.F. TOTAL HABITABLE 1,504 S.F. (GROSS) TOTAL BUILT 2,142 S.F. (GROSS) OVERALL TOTAL BUILT 2,142 S.F. 1) REMOVE EX. WALL BETWEEN DINING ROOM AND KITCHEN 2) REMOVE EX. CLOSET AND LINEN AND CREATE NEW CLOSET FOR BEDROOM #1 3) PROPOSED NEW KITCHEN CABINETS AND NEW ISLAND 4) ADDITION UNDER SEPARATE PERMIT (101119806) 2 NOTE: DIGITAL STAMPS AND SIGNATURES 1311 N Towner 12/12/2024 1/4"=1'0" STRUCTURAL TITLE SHEET S REVISION(S) 1 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M JULY. 2024 24-199 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 11-01-2024 SEISMIC DESIGN DATA SEISMIC IMPORTANCE FACTOR =1.0 SS = 1.308 S1 =0.466 SITE CLASS = D Fa = 1.20 Fv =1.70 SDS = 1.046 SD1 = 0.559 THE REDUNDANCY FACTOR () =1.3 SEISMIC DESIGN CATEGORY = D SEISMIC FORCE RESISTING SYSTEM(s) = -LIGHT FRAMED WALLS WITH SHEAR PANELS DESIGN BASE SHEAR V=0.16 W, (SD) =8.67 k,(SD) =0.11 W, (ASD)=6.19 k, (ASD) SEISMIC RESPONCE COEFFICIENT (s), Cs =0.2 CS= SDS /R 1 \ RESPONSE MODIFICATION FACTOR (s), R =6.5 ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL-FORCE PROCEDURE DESING LOADS ROOF LIVE LOAD =20 psf ROOF DEAD LOAD =20 psf STRUCTURAL OBSERVATION IS REQUIRED FOR THE PROJECT AND SHALL BE PERFORMED BY THE ENGINEER OF RECORD OR HIS DESIGNEE AS FOLLOW: 1 PRIOR TO POURING OF FOUNDATION (INSPECTION OF EXCAVATION, STEEL REINFORCEMENT, ANCHOR BOLTS, AND HOLD-DOWN BOLTS. CALL PRIOR TO ORDER OF CONCRETE) 2 AT THE COMPLETION OF ROUGH FRAMING 3 WHERE APPLICABLE, AT ERECTION OF STEEL/CONCRETE/MASONRY COLUMNS, BEAMS AND WALLS AND INSTALLATION OF MANUFACTURED WALLS( SIMPSON WALL OR HARDYFRAME) 4 PRIOR TO PLACEMENT OF ROOFING MATERIALS FOR NAILING OF ROOF SHEATHING. CONTRACTOR TO REVIEW WITH FRAMING SUBCONTRACTOR THE STRUCTURAL DRAWINGS, THE FLOOR PLANS AND INTERIOR ELEVATION SHEET AND VERIFY ALL SOFFITS, ARCHES AND SPECIAL FRAMING CONDITIONS AND REPORT TO THE ARCHITECT(s) / ENGINEER(s) ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR TO CONFIRM BEAM SIZES, CALL OUTS, SHEAR WALL LOCATIONS. BRING TO THE ARCHITECT(s) / ENGINEER(s) ATTENTION ANY DISCREPANCIES FOUND PRIOR TO START OF CONSTRUCITON. CONTRACTOR TO SCHEDULE FRAMING WALK-THROUGH WITH ARCHITECT(s) / ENGINEER(s) AFTER FRAMING IS CONSIDERED COMPLETED AND SHALL NOT COVER WALLS WITH INSULATION OR DRYWALL UNTIL ARCHITECT(s) / ENGINEER(s) HAVE SIGNED OFF WITH A STRUCTURAL OBSERVATION FORM. SPECIAL INSPECTION Shall be performed by special licensed inspector per sec. 1704 C.B.C. at the following times: ITEM REMARK REQUIRED NOT APPLICABLE SOIL COMPLIANCE PRIOR TO FOUNDATION INSPECTION X STRUCTURAL CONCRETE OVER 2500PSI OR STRUCTURAL GRADE BEAM & CAISSONS @3000PSI MINIMUM CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED FOR ALL CONCRETE DESIGNED WITH F'C GREATER THAN 2500PSI X FIELD WELDING FIELD WELDING MUST BE DONE BY WELDERS CERTIFIED BY THE GOVERNING AGENCY X IF USED EXPANSION ANCHORS USE IN INTERIOR FOOTINGS ONLY SIMP. SET-XP EPOXY FOR BOLTS DRILLED INTO CONCRETE INSTALL PER ICC ESR-2508 OR LARR 25744 X IF USED ANCHORS IN DRY-PACK FOR BOLTS DRILLED INTO CONCRETE INSTALL PER LARR 24968 X MANUFACTURED WALLS (SIMPSON STEEL WALL, HARDY FRAMES A LICENSED FABRICATOR IS REQUIRED BY THE GOVERNING AGENCY. CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED FOR ALL MANUFACTURED WALLS X IF USED STRUCTURAL NOTES UNLESS OTHERWISE NOTED THE FOLLOWING SHALL APPLY 1 SOIL BEARING VALUE IS ASSUMED 1,500 psf PER TABLE 1806.2 UNLESS A SOILS REPORT STATES OTHERWISE 2 AT ROOF DIAPHRAGM USE 15/32" CD-CC PLY. OR O.S.B. EQ. P.I. 32/16 W / 8d NAILS @ 6" O.C. EDGES & 12" O.C FIELD NO BLKG. REQ (U.N.O) 3 AT FLOOR DIAPHRAGM USE T & G 5/8" CD-CC PLY. OR O.S.B. EQ. W / 10d NAILS @ 6" O.C EDGES & 12" O.C. FIELD (U.N.O) *4 AT SHEAR WALL TYPE 4&5 USE 3X NOMINAL FRAMING AT ALL PLYWOOD EDGES WHERE NAILING IS @ 2" O.C. OR LESS 5 BOLT HOLES SHALL BE 1/16" (MAX) OVERSIZED AT THE CONNECTOR OF THE HOLDOWN. INSPECTOR TO VERIFY. 6 HOLDOWN CONNECTORS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 7 HOLDOWN ANCHOR BOLTS SHALL BE CONNECTED TO WOOD POSTS (4X MIN.) 8 CONNECTIONS AND FASTENERS SHALL COMPLY WITH TABLE 2304.10.2 (SEE DETAIL) 9 AT SHEAR VALUE GREATER THAN 350 PLF USE MIN 3x FRAMING AT ALL PLYWOOD EDGES AND MIN OF 1/2" FROM PANEL EDGE AND NOT LESS THAN 3/8" FROM THE EDGE OF CONNECTING MEMBERS 10 FOR THE NAILING. 2-2X MEMBERS JOINED W/ 16d NAILS @ 3" O.C. MAY BE USED IN-LIEU OF 3X MEMBER. 11 PROVIDE DBL F/J OR LINE OF FULL HT 2X BLOCKINGS UNDER 2ND FLOOR WALLS 12 FOR ALL PLYWOOD NAILING USE COMMON NAILS STAGGER (WHERE APPLICABLE) AND BLOCK ALL EDGES FOR ALL SHEARWALLS 13 ANCHOR BOLTS TO SILL MUST START MIN 3 " AND MAX 12" FROM SILL END MIN 2 ANCHOR BOLTS PER SHEAR PANNEL 14 15 SAME SIZE A307 THREADED ROD W/HILTI HIT-RE500-SD ADHESIVE ANCHOR MAY BE USED IN LIEU OFANCHOR BOLTS MIN 5"INTO CONCRETE W/ MIN EDGE DIST. 1 3/4 IN.) INSTALL PER LARR-25700 ESR-2322 OR APPROVED EQUAL. (SPECIAL INSPECTION IS REQUIRED). 16 IN LIEU OF ANCHOR BOLT HOLD DOWN BOLTS SIMP. SET XP EPOXY MAY BE USED INSTALL PER ICC ESR-2508 OR LARR-25744 MIN EMBEDMENT INTO CONC. 9-1 2" FOR 5 8 BOLTS 11-1 4" FOR 3 4"BOLTS AND 13-1 8" FOR 7 8" BOLTS (SPECIAL INSPECTION IS REQUIRED ) 17 PROVIDE 2 LAYERS OF GRADE "D" PAPER AT EXTERIOR SHEARWALL SHEATHING. MAX STUD SPACING 16" O.C 18 ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 19 3"X3"X0.229 PLATE WASHERS WITH SLOTTED CUT HOLE PER 2308.3.1.1 ARE REQUIRED FOR ALL HOLD DOWNS CONNECTION TO WOOD POSTS &SILL PLATE. FOUNDATION NOTES UNLESS OTHERWISE NOTED THE FOLLOWING SHALL APPLY 1 ANCHOR BOLTS FOR WALLS SHALL BE 5/8 Ø X 12" LONG EMBEDED 9" MIN INTO FIRST POUR OF ALL CONTINUOUS CONCRETE FOOTINGS AND SPACED AT 48"O.C MAX WITH PLATE WASHERS 3" X 3" X 0.229" U.N.O. 2 ANCHOR BOLTS SHALL START MIN 4-1/2 " AND MAX 12" OF SILL END WITH MIN 2 BOLTS PER WALL. 3 FOR INTERIOR NON BEARING WALLS SIMP. PDPWL 300 OR APPROVED EQ. @ 24"O.C MAY BE USED IN 4" MIN CONCRETE SLAB AND MUST BE INSTALLED PER MNFG SPECS IN CONFORMANCE WITH ICC ER-4546. 4 HD'S SHALL BE TIED AND INSTALLED IN PLACE AND INSPECTED PRIOR TO POURING OF CONCRETE. ALL SIMPSON ANCHORS TO BE INSTALLED PER MNFG SPECS AND IN CONFORMANCE WITH THE LATEST ICC REPORTS. 5 THE CONCRETE COMPRESSIVE STRENGTH OF ALL FOOTINGS AND SLABS SHALL BE A MINIMUM OF F'C=2500 PSI 6 ALL CONTINUOUS CONCRETE FOOTINGS SHALL BE REINFORCED WITH #4 BARS GRADE 60 CONFORMING TO ASTM A-615 ON TOP AND BOTTOM OF FOOTINGS. 7 INTERIOR SLABS SHALL HAVE MESH REINFORCING CONFORMING TO ASTM A-165 U.N.O. 8 MINIMUM SPLICE FOR REINFORCING STEEL SHALL BE 30 BAR DIAMETER OR 2 FEET 9 SEE 1ST FLOOR SHEARWALL SCHEDULE FOR BOLT SIZES AND MINIMUM SPACING 10 ALL SURFACE WATER SHALL DRAIN AWAY FROM BUILDING AND WALLS AT 2% MINIMUM 11 SAME SIZE HILTI EXPANSION BOLTS 7" INTO FIRST POUR CONC. MAY BE USED IN LIEU OF ANCHOR BOLTS. MIN CONC. EDGE DIST. = 2" 12 SAME SIZE BOLTS 5" MIN. INTO CONC. MAY BE USED W/SIMP. SET XP EPOXY PER ICC ESR-2508 OR RR-25744 WITH MIN CONC. EDGE DIST 1-3 4" ( SPECIAL INSPECTION IS REQUIRED ) 13 FOR HOLD DOWN BOLTS SIMP. SET XP EPOXY MAY BE USED INSTALL PER ICC ESR-2508 OR LARR-25744. MIN EMBEDMENT INTO CONC. 9-1 2" FOR 5 8 BOLTS 11-1 4" FOR 3 4"BOLTS AND 13-1 8" FOR 7 8" BOLTS. ( SPECIAL INSPECTION IS REQUIRED ) 14 CONCRETE DRIVEWAYS & OTHER LARGE CONC. SLABS SHOULD HAVE CRACK CONTROL JOINTS @ ± 10' O.C.. SMALL SLABS SHOULD HAVE CRACK CONTROL JOINTS @ ± 5' O.C. 15 ALL FOUNDATION EXCAVATION ARE TO BEAR IN LIKE MATERIAL 16 ALL SHEAR AND ANCHOR BOLTS WITH NON-STANDARD SPACING ARE TO BE TIED IN PLACE AT FOOTING INSPECTION 17 SATURATE THE SOIL 18" DEEP BEFORE PLACING THE CONCRETE SLAB 18 IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, CONSULT W/SOILS ENGINEER AND/OR ENGINEER OF RECORD. 19 IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. ROOF DIAPHRAGM USE 15/32 CDX APA RATED W/ 8d COMMON NAILS @ 6:6:12 OR O.S.B. EQ. (TYP.) P.I. 32/16 SEE DETAIL 70/SD3 SHEET INDEX THE GOVERNING CODES FOR THIS PROJECT ARE: FLOOR DIAPHRAGM USE 5/8" MIN. PLY. CD T&G W/ 10d COMMON NAILS @ 6:6:12 OR O.S.B. EQ. (TYP.) P.I. 32/16 SEE DETAIL 70/SD3 FLOOR SLAB CONCRETE FOOTINGS USE MIN 2500 PSI AT 28 DAYS WITH 2 -#4 BARS TOP & BOTTOM RISK CATEGORY =II FLOOR LIVE LOAD =40 psf FLOOR DEAD LOAD =12 psf BALCONY LIVE LOAD =60 psf WIND DESIGN DATA BASID WIND SPEED (mph) =110 RISK CATEGORY =II WIND EXPOSURE =C INTERNAL PRESSURE COEFFICIENT = +0.18 -0.18 FULL LEGEND IS SHOWN FOR REFERENCE ONLY. ONLY APPLICABLE CALLED OUT PADS ON FOUNDATION PLAN APPLY. FULL LEGEND IS SHOWN FOR REFERENCE ONLY. ONLY APPLICABLE CALLED OUT POSTS ON FLOOR FRAMNG AND/OR ROOF FRAMING PLAN APPLY. SHEAR WALL SCHEDULE PER 2021 SDPWS TABLE 4.3A S.W. TYPE SHEAR PANEL DESCRIPTION SHEAR VALUE # / FT REDUCED SHEAR VALUE (# / FT) TOP PLATETO BLK'G OR JOIST SILL PLATE CONNECTION TO FLR BELOW OR FOUNDATION HEIGHT / WIDTH REDUCED HEIGHT / WIDTH 15/32" CD, CC PLWD (4PLYS) OR O.S.B. EQ. W/ 8d COMMON NAILS @ 6"O.C. @ BNDRY/EDGES & 12"O.C. FIELD (FOR BACKING ONLY) N/A N/A SIMP. A35 @32" O.C. 16d Common Nails @ 4"O.C. for wood or 5/8" dia x 12" A.B. @ 48" O.C. W/3"X3"X0.229" Steel plate washer. 7/8" STUCCO OVER PAPER-BACKED LATH W/11 GAUGE 1-1/2" LONG, 7/16" DIAM HEAD NAIL FURRED MIN 1/4" @ 6" O.C @TOP & BOTTOM PLATES, EDGE OF SW & AT ALL STUDS 90 UNBLOCKED 90 BLOCKED SIMP. A35 @32" O.C. 16d Common Nails @ 4"O.C. for wood or 5/8" dia x 12" A.B. @ 48" O.C. 9" min. into conc. and W/3"X3"X0.229" Steel plate washer.1 1/2 : 1 2 : 1 15/32" STRUCTURAL I (4PLY) CD, CC-A.P.A. RATED PLYWD. OR O.S.B. EQ. W/ 8d COMMON NAILS AT 6"O.C. @ EDGES & BOUNDARY AND 12" O.C. ON FIELD 280 160 SIMP. A35 @16" O.C. 16d Common Nails @ 4"O.C. for wood or 5/8" dia x 12" A.B. @ 48" O.C. 9" min. into conc. and W/3"X3"X0.229" Steel plate washer.2:1 3 1/2 : 1 15/32" STRUCTURAL I (4PLY) CD, CC-A.P.A. RATED PLYWD. OR O.S.B. EQ. W/ 10d COMMON NAILS AT 6"O.C. @ EDGES & BOUNDARY AND 12" O.C. ON FIELD 340 199 SIMP. A35 @12" O.C. 16d Common Nails @ 3"O.C. staggered for wood or 5/8" dia x 12" A.B. @ 32" O.C. 9"min. into conc. and W/3"X3"X0.229" Steel plate washer.2:1 3 1/2:1 15/32" STRUCTURAL I (4PLY) CD, CC-A.P.A. RATED PLYWD OR O.S.B. EQ. W/ 10d COMMON NAILS AT 3" O.C. @ EDGES & BOUNDARY AND 8" O.C. ON FIELD. USE 3X NOMINAL FRAMING @ SILL PLATE & PLWD EDGES 665 379 SIMP. A35 @6" O.C. 1/4" x6" SDS screews @ 6"O.C. staggered (Use 3x Blk'g) or 5/8" dia x 12" A.B. @ 24" O.C. 9"min. into conc. and W/3"X3"X0.229" Steel plate washer.2:1 3 1/2:1 15/32" (4PLY) STRUCTURAL I PLWD OR O.S.B. EQ. W/ 10d COMMON NAILS AT 3" O.C. @ EDGES & BOUNDARY AND 8" O.C. ON FIELD. USE 3X NOMINAL FRAMING @ SILL PLATE & PLWD EDGES 1330 758 SIMP. A35 @6" O.C. EA. SIDE 1/4" x6" SDS screws @ 3"O.C. staggered (Use 3x Blk'g) or 5/8" dia x 12" A.B. @ 12" O.C. 9"min. into conc. and W/3"X3"X0.229" Steel plate washer.2:1 3 1/2:1 15/32" (MIN. 4PLY) STRUCTURAL I PLWD OR O.S.B. EQ. W/ 10d COMMON NAILS AT 2" O.C. @ EDGES & BOUNDARY AND 8" O.C. ON FIELD. USE 3X NOMINAL FRAMING @ SILL PLATE & PLWD EDGES 870 496 SIMP. A35 @5" O.C. 1/4" x6" SDS screws @ 4"O.C. staggered (Use 3x Blk'g) or 5/8" dia x 12" A.B. @ 12" O.C. 9"min. into conc. and W/3"X3"X0.229" Steel plate washer.2:1 3 1/2:1 15/32" (MIN. 4PLY) STRUCTURAL I PLWD OR O.S.B. EQ. W/ 10d COMMON NAILS AT 2" O.C. @ EDGES & BOUNDARY AND 8" O.C. ON FIELD. USE 3X NOMINAL FRAMING @ SILL PLATE & PLWD EDGES 1740 992 SIMP. A35 @5" O.C. EA. SIDE 1/2" x6" Lag Bolts @ 3"O.C. (Use 3x Blk'g) or 5/8" dia x 12" A.B. @ 6" O.C. 9"min. into conc. and W/3"X3"X0.229" Steel plate washer.2:1 3 1/2:1 USE MANUFACTURED WALL OR APPROVED EQUAL BY ICC. INSTALL PER MANUFACTURE(S) RECOMENDATIONS FOR HOLD DOWN AND ANCHOR BOLTS. ± 1000 PER MFG. CATALOGUE PER MFG. CATALOG USE MANUFACTURE TEMPLATE PER MFG. RECOMENDATION -Anchor bolts shall be connected to sill plate w/ 3-inch by 3-inch by 0.229 inch plate washer (per table 2303.3.11) * All framing members receiving edge nailing from abutting panels shall not be less than a single 3-inch nominal member, or two 2-inch nominal members fastened together w/16d face nails @ 3" o.c. wood structual panel joint and sill plate nailing shall be staggereed in all cases. * Use 3x sill plate for shear walls with a design load of over 350 plf. * Special inspection is required for wood diaphrams and shear wall with nailing at 4" on center or less. * Studs shall be connected to sill/sole plates with 2-16d end nails or 4-16d toe nials. Δ The sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by two times the number of bolts required by deign and 0.229-inch by 3-inch by 3-inch plate washers are used. Ω Where panels applied on both faces of a wall, panel joints shall be offset to fall on different framing members, or framing shall 3-inch nominal or thicker at adjoining panel edges and nails on each side shall be staggered. * * x This type of shear wall is not required based on lateral analysis it is provided as an additional shearwall to increase the lateral performance of the structure (conservative measure) X 1 2 3 4 4 4 5 5 5 6 20 ALL SIMPON STRONG TIE HARDWARE MUST BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS NOTE: ALL PADS SHALL BE MIN. 24" DEEP UNLESS SPECIFIED OTHERWISE ON DETAILS A B C D USE 4" CONC. SLAB. W/ #4 BARS @ 16" O.C. EACH WAY OVER 2" SAND OVER 10 MIL. VISQUEEN OVER 4" MIN.THICK BASE OF 1 2" OR LARGER CLEAN AGGREGATE REPORT NUMBERS UNLESS OTHERWISE NOTED THE FOLLOWING SHALL APPLY PRODUCTS INTERNATION CODE COUNCIL CITY AGENCY HOLDOWNS ESR-2330 LA RR 25720 ANCHOR BOLTS W/ SIMPSON SET-XP EPOXY ESR-2508 LA RR 25744 ANCHOR BOLTS W/SIMPSON SET-XP EPOXY (UNREINFORCED MANSONRY WALLS) ESR-2508 LA RR 25744 ANCHOR BOLTS W/ SIMPSON SET-EPOXY ESR-1772 LA RR 25279 HANGERS ESR-2552 LA RR 25807, LA RR 25800, LA RR 25803 STRAPS ESR-2105 LA RR 25713 LTT-HTT LA RR 25818-IAPMO COLUMN CAPS ESR-2604 LA RR 25714 HARDY FRAME ESR-2089 LA RR 25759 PARALLAM ESR-1387 LA RR 25202 SDS SIMP. WOOD SCREWS ESR-2236 LA RR 25711 PDPAWL ESR-2138 LA RR 25469 ESR-1161BEARING PLATES (BP), ANCHOR PLATE (FAP), TENSION TIE (HTT22) LATERAL TIE PLATE (LTP4) LA RR 25293 ER-130, ICC-ES AC155 SIMPSON STRONG WALLS ESR-2652 ESR-1679SIMPSON STEEL STRONG WALLS A34 / A35 ESR-3096 - ER 112 ESR-2330 ESR-2508 ESR-2508 ESR-2611SSTB-SB SAME SIZE SIMPSON WEDGE ANCHOR MAY BE USED IN LIEU OF ANCHOR BOLTS MIN 7"INTO CONCRETE and FULLY GROUTED CMU MASONRY OR MIN EDGE DIST. 6 1/2 IN.) INSTALL PER ICC ESR-1396 AND LARR-24682. 1311 N Towner 12/12/2024 UP UP UP UP 1/4"=1'0" FOUNDATION & ROOF PLAN S1 REVISION(S) 1 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M JULY. 2024 24-199 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 11-01-2024 1311 N Towner 12/12/2024 REVISION(S) 1 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M JULY. 2024 24-199 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 11-01-2024 N.T.S. STRUCTURAL NOTES SN1 1311 N Towner 12/12/2024 REVISION(S) 1 2 3 Scale: Date: Project #: PR O J E C T A D D R E S S OW N E R MI D - C I T I E S E N G I N E E R I N G R E S E R V E S I T S C O P Y R I G H T S T O T H E S E P L A N S A N D D R A W I N G S . W R I T T E N P E R M I S S I O N A N D C O N S E N T O F M . C . E . I S R E Q U I R E D P R I O R T O C H A N G I N G , R E P R O D U C I N G , C O P Y I N G I N A N Y F O R M O R M A N N E R W H A T S O E V E R O R A S S I G N I N G T O A N Y T H I R D P A R T Y . ( r e v 1 - 1 - 1 8 ) MI D C I T I E S E N G I N E E R I N G RE S I D E N T I A L C O M M E R C I A L I N D U S T R I A L 97 4 4 M A P L E S T . # 1 0 1 BE L L F L O W E R , C A 9 0 7 0 6 PH : ( 5 6 2 ) 8 6 6 - 3 6 2 5 , F X : ( 5 6 2 ) 2 3 2 - 4 1 2 1 WW W . M I D C I T I E S E N G I N E E R I N G . C O M JULY. 2024 24-199 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 DE A N H A L L (7 1 4 ) 8 6 4 - 1 6 3 2 13 1 1 N T O W N E R S T . , SA N T A A N A , C A 9 2 7 0 6 11-01-2024 N.T.S. STRUCTURAL NOTES SN2 x × × × x x x x x x x x x x x x x x x x × x x — x x x x x 1311 N Towner 12/12/2024 1311 N TOWNER ST SANTA ANA CA 92706 Work Description INTERIOR REMODELING Code 2022 California Building Code W/ Local Amendments Job Number 24-199 Date 24-Jul-24 We are engaged in providing structural calculations and consultation in relation to the above-described project. We have no authority insofar as contractor or owner’s personnel are concerned. It is solely the responsibility of the owner and/or contractor to observe all safety ordinances for protection of personnel. In making use of this document, the contractor/owner agree to hold our company harmless from all costs of litigation that may arise out of alleged damages or injuries associated with the work defined by this document. The designer provided all information regarding this project to our company. We did not make any inspection or investigation of the site. The calculations and details provided in this document are applicable only if the information provided to us is adequate and reflective of field conditions. In case of any discrepancies, please contact us immediately. MCE2020@GMAIL.COM Tel: (562) 866-3625 STRUCTURAL CALCULATIONS Midcities Engineering 9744 Maple St. Suite # 101 Bellflower, CA 90706 www.MidCitiesEngineering.com Job Address Responsibility 1311 N Towner 12/12/2024 FOUNDATION ANALYSIS (F) FOUNDATION ANALYSIS AND DESIGN SOIL BEARING PRESSURE IS LIMITED TO (PER TABLE 1806.2-UNLESS A SOIL REPORT IS SUBMITTED) : σ =1500 psf (IN CASE THE FOOTING DEPTH IS EQUAL TO 24" USE 10% INCREASE) 1- CONTINUOUS FOOTING UNIFORM LOAD: 12" WIDE = 15" WIDE = 18" WIDE = 2- CONCENTRATED LOAD ON CONTINUOUS FOOTING LOAD CAPACITY 12" WIDE BY 12" BELOW FINISH GRADE CONCENTRATED LOAD: L = 36 + 3.50 L = 39.5 in W= 3.5 in L = 39.5 x 12 = 474 in x = LBS S.F 15" WIDE BY 18" BELOW FINISH GRADE L = 48 + 3.50 D L = 51.5 in L = 51.5 x 15 = 772.5 in x = LBS S.F L=2*D+W D= FOOTING HIGHT+6" 18" WIDE BY 24" BELOW FINISH GRADE L = 60 + 3.50 L = 63.5 in L = 63.5 x 18 = 1143 in x = LBS S.F 3- CONCENTRATED LOAD ON PAD FOOTING, LOAD CAPACITY 12" DEEP Pall = 2.25 ft x σ Pall = 4 ft x σ 42" SQ Pall = lb 18SQ Pall = 3375 lb 24SQ Pall = 6000 lb 44" SQ Pall = lb 48" SQ Pall = lb Pall = 6.25 ft x σ Pall = 9 ft x σ 54" SQ Pall = lb 30SQ Pall = 9375 lb 36SQ Pall = 13500 lb Pall = 11.11 ft x σ 40SQ Pall = 16665 lb PAD FOOTING DESIGN: ASSUME ALLOWABLE SOIL PRESSURE = 1500 PSF PER TABLE 18-1-1 REACTION STATUS FOUND R CAPACITY 3814 NO FOUND 0.00 3146 NO FOUND 0.00 944 EX. FOUND 3.25 MEMBERS B1L A = R/1500 ft2 5.36 PAD NAME 4937.50 8046.88 13096.88 18375 20166 24000 30375 1500 lb/ft (F1) 24"*24"*24"2.54 S.F 2250 lb/ft 1875 lb/ft PAD AREA 8.73 3.29 1311 N TOWNER ST. SANTA ANA 8/6/202 SHEET OF CALCULATION 1311 N TOWNER ST SANTA ANA CA PROJECT NAME SUBJECT PAD DESIGN PROJECT NUMBER ADDRESS DAT FOUNDATION ANALYSIS B2L 0.63 S.F NO PAD B2R 2.10 S.F (F1) 24"*24"*24" σ 144 σ 144 σ 144 F1 1311 N Towner 12/12/2024 DATE: 8/23/2023 COMPANY: Mid-Cities Engineering STRUCALC BUILD: StruCalc Pro DESIGNED BY: Mid Cities Engineers CUSTOMER: MID-Cities Engineering REVIEWED BY: Mid Cities Engineers PROJ. ADDRESS: 9744 Maple St Suite 101 Bellflower, CA 90706 PROJECT SUMMARY Project Name: 24-107 1311 N TOWNER ST. SANTA ANA CA 92706 (5-9-24) Governing Codes:Building Code: 2021 International Building CodeASCE: ASCE 7-16Steel: AISC 360-16Concrete: ACI 318-19Masonry: TMS 402/602-16 Page 1 2021 International Building Code ASDPROJECT: 24-107 1311 N TOWNER ST. SANTA AN... Module Location: (B1) 5.25X9.5 PRLLM PSL 2.0E Module Level: Roof Module Type: Roof Beam Material Type: Structural Composite Lumber Weyerhaeuser 2.0E Parallam PSL Member Dimensions: (1) 5.25 in. X 9.5 in. X 12 ft Section Adequacy:34.12% Controlling Factor: Deflection Y Module Location: (B2) 5.25X9.5 PARALLAM PSL 2.0E Module Level: Roof Module Type: Roof Beam Material Type: Structural Composite Lumber Weyerhaeuser 2.0E Parallam PSL Member Dimensions: (1) 5.25 in. X 9.5 in. X 17.75 ft Section Adequacy:24.81% Controlling Factor: Deflection Y 1311 N Towner 12/12/2024 PASS DATE: 8/23/2023 COMPANY: Mid Cities Engineers STRUCALC BUILD: StruCalc Pro DESIGNED BY: Mid Cities Engineers CUSTOMER: MID-Cities Engineering REVIEWED BY: Mid Cities Engineers PROJ. ADDRESS: 9744 Maple St Suite 101 PROJECT NAME: 24-107 1311 N TOWNER ST. SANTA ANA CA 9... Bellflower, CA 90706 LEVEL: Roof LOADING: ASD MEMBER NAME: (B1) 5.25X9.5 PRLLM PSL 2.0E CODE: 2021 International Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Structural Composite Lumber Weyerhaeuser 2.0E Parallam PSL (1) 5.25 X 9.5 DRY (B1) 5.25X9.5 PRLLM PSL 2.0E DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 12 Member Slope: 0/12 Actual Length (ft): 12 Area Ix Iy BSW Lams Cfn Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 49.88 375.1 114.56 15.59 1 9 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 2900 2300 290 2900 625 2000 1016.535 Adjusted Values 2900 2300 290 2900 625 2000 1017 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 Bending Adjustment Factors C V = 1.03C r = 1 Volume factor Is applied on a load combination basis And Is Not reflected in the adjusted values BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 12 0 12 0 1.00 0.98 1.00 1.00 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (68.4%) PASS (53.3%) PASS (34.1%) PASS (61.3%) MAGNITUDE 114.7 1738.5 0.395 (=L/365) 242.1 STRENGTH 362.5 3720.3 0.600 (=L/240) 625.0 LOCATION (ft) 12 6 6 0 LOAD COMBO D+Lr D+Lr D+Lr D+Lr DURATION FACTOR CD 1.25 1.25 1.25 1.25 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 1954 1860 3814 B 1954 1860 3814 Reaction Location A B Page 2 2021 International Building Code ASDPROJECT: 24-107 1311 N TOWNER ST. SANTA AN... 1311 N Towner 12/12/2024 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Uniform 310 310 0 12 RoofLive Y Uniform (lbf/ft) Uniform 310 310 0 12 Dead Y Self Weight (lbf/ft) - 15.59 15.59 0 12 Dead Y Page 3 2021 International Building Code ASDPROJECT: 24-107 1311 N TOWNER ST. SANTA AN... Member Name: (B1) 5.25X9.5 PRLLM PSL 2.0E 1311 N Towner 12/12/2024 PASS DATE: 8/23/2023 COMPANY: Mid Cities Engineers STRUCALC BUILD: StruCalc Pro DESIGNED BY: Mid Cities Engineers CUSTOMER: MID-Cities Engineering REVIEWED BY: Mid Cities Engineers PROJ. ADDRESS: 9744 Maple St Suite 101 PROJECT NAME: 24-107 1311 N TOWNER ST. SANTA ANA CA 9... Bellflower, CA 90706 LEVEL: Roof LOADING: ASD MEMBER NAME: (B2) 5.25X9.5 PARALLAM PSL 2.0E CODE: 2021 International Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Structural Composite Lumber Weyerhaeuser 2.0E Parallam PSL (1) 5.25 X 9.5 DRY (B2) 5.25X9.5 PARALLAM PSL 2.0E DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 17.75 Member Slope: 0/12 Actual Length (ft): 17.75 Area Ix Iy BSW Lams Cfn Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 49.88 375.1 114.56 15.59 1 9 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 2900 2300 290 2900 625 2000 1016.535 Adjusted Values 2900 2300 290 2900 625 2000 1017 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 Bending Adjustment Factors C V = 1.03C r = 1 Volume factor Is applied on a load combination basis And Is Not reflected in the adjusted values BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 17.75 0 17.75 0 1.00 0.97 1.00 1.00 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (73.9%) PASS (52.5%) PASS (24.8%) PASS (68.0%) MAGNITUDE 94.6 1765.6 0.667 (=L/319) 199.8 STRENGTH 362.5 3720.3 0.887 (=L/240) 625.0 LOCATION (ft) 0 3.727 7.81 0 LOAD COMBO D+Lr D+Lr D+Lr D+Lr DURATION FACTOR CD 1.25 1.25 1.25 1.25 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 1679 1467 3146 B 551 393 944 Reaction Location A BLOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Self Weight (lbf/ft) - 15.59 15.59 0 17.75 Dead Y Page 4 2021 International Building Code ASDPROJECT: 24-107 1311 N TOWNER ST. SANTA AN... 1311 N Towner 12/12/2024 LINKED LOAD LIST Type Member Support Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf)(B1) 5.25X9.5 PRLLM PSL 2.0E B 1953.516 - 3.75 - Dead Y Point (lbf)(B1) 5.25X9.5 PRLLM PSL 2.0E B 1860 - 3.75 - RoofLive Y Page 5 2021 International Building Code ASDPROJECT: 24-107 1311 N TOWNER ST. SANTA AN... Member Name: (B2) 5.25X9.5 PARALLAM PSL 2.0E 1311 N Towner 12/12/2024