HomeMy WebLinkAbout1312 S Hickory St - PlanPAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA ANA, CA, 92707 PROJECT NUMBER: 109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. CEC 2022. CEC 2022. INVERTER. SYSTEM COMPLIES WITH 690.41(A). ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS 13.51 AMPS MODULE SHORT CIRCUIT CURRENT. VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). THROUGH A WALL OR PARTITION PER 706.15(D). THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) 3) TESLA MID CIRCUIT INTERRUPTER (MCI-2) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE ENERGY STORAGE SYSTEM: (1) TESLA: POWERWALL 3 1707000-XX-Y WITH INTEGRATED INVERTER: 13.5 kWh PER PW3 TOTAL ENERGY CAPACITY: (IN kWh): 27kWh (1) TESLA: POWERWALL 3 EXPANSION 1807000-XX-Y ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING, SNR-DC-00339 INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CONT. PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUP LOADS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE NEW 125 AMP LOAD CENTER TO BE INSTALLED. EXISTING SYSTEM SIZE: 5.85KW DC, 3.8KW AC COMBINED SYSTEM SIZE: 8.91KW DC, 15.3KW AC Bldg #101123331 Elect #20185628 APPROVALS: ELECT - M. Smith ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** 1312 S Hickory St 5/5/2025 PL PL PL PL PL PL PL PL PLPLPLPL PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 S  H I C K O R Y   S T SITE PLAN PV-2.0 (E) SHED #SSTAMPSP #ESTAMPSP POWERWALL ENERGY  STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANELMAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METERSERVICE ENTRANCE  INTERIOR EQUIPMENT  SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMAGROUNDING  ELECTRODE ENERGY STORAGE  SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE  1 COMMUNICATION  WIRES AM MD MICROGRID  INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEM PV LOAD CENTERLC LEGENG SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 2643 SQFT.  TOTAL PV ARRAY AREA (E+N) : 494.6 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 (E+N) = 18.71% RAIL STANDOFFS &  FOOTINGS SOLAR  MODULES ARRAY  PITCH PV AREA  (SQFT) AR-01 10° 167.93 TRUE  AZIM MAG  AZIM 78°90° ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN  ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED  FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE  SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE  ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID  SHUTDOWN DEVICE INSTALLED PER CEC 690.12 SITE PLAN - SCALE = 1/16" = 1'-0" A A A A A A A A MD (E) RESIDENCE (N) ARRAY AR-01 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) (E) GATE (TYP.) MP SE ACINV    (E) PV ARRAY  (E) PV EQUIPMENT INV AC    LC ROOF PATHWAYS (3' TYP) (E) CLOTH GAZEBO I V IL REGISTERED PROFESSIONAL ENGINEER STATE OF C ALIFORNIA ROBERT SMYTHEC56136 EXP. 12/31/26 1312 S Hickory St 5/5/2025 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. UMBRELLA  SCREW: 2.5" MIN EMBEDMENT  INTO FRAMING PV-3.0 LAYOUT 4" SOLAR MODULE SNAPNRACK  RACKING MODULE ELEVATION DETAIL - SCALE: NTS ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max  Span OC  Spacing Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X6 RAFTERS 12'-5" 16" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 5'-4"2'-1"5'-4"2'-1"STACKED INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL  ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM:90° PITCH:10° 5'-4" TYP 30'-2" 5'-8" 1'-10"9'-7" 16'-2" 10" 5" 4'-5" 5'-7" * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"  BOUNDARY REGION OF ANY ROOF PLANE  EDGES (EXCEPT VALLEYS), THEN  ATTACHMENTS NEED TO BE ADDED AND  OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING  INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON  PLANS TO BE 1/5TH OF ALLOWABLE  ATTACHMENT SPACING INDICATED ON PLANS. I V IL REGISTERED PROFESSIONAL ENGINEER STATE OF C ALIFORNIA ROBERT SMYTHEC56136 EXP. 12/31/26 1312 S Hickory St 5/5/2025 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL INSTALLED SECTION VIEW DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO RAFTERSNR-DC-00339 1 5 7 2019 NEW DETAIL 1 6 18 2019 DRO-00138 B 6 22 2023 DC002707 REV: ADATE: DNS 6 22 2023 DRAFTER:    M.AFFENTRANGER E.FERGUSON M.AFFENTRANGER Solar Mounting Solutions MJA MJA MJA BIN: 8 214" 112" 112" 158" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 516"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212" INTO STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING. REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE REFER TO SNAPNRACK INSTALLATION MANUAL FOR516"Ø HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447" STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. SNAPNRACK5 16"n UMBRELLA LAG SCREW, S.S. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL SNAPNRACK UMBRELLA FLASHING 212" MIN. EMBEDMENT INTO WOOD MEMBER MODULE HEIGHT OFF ROOF: UR-40: 338" - 438" UR-60: 4" - 5" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA LAG AND FLASHING SNAPNRACK UMBRELLA FLASHING #SSTAMP PV-3.1 MOUNTING DETAIL I V IL REGISTERED PROFESSIONAL ENGINEER STATE OF C ALIFORNIA ROBERT SMYTHEC56136 EXP. 12/31/26 1312 S Hickory St 5/5/2025 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 EXISTING 200/200A MAIN  PANEL SCHEDULE NEW 125A LOAD  CENTER 60 NEW PV +ESS  BREAKER 20 0 20 EXISTING PV  BREAKER 70 20 10 0 FEEDER  BREAKER TRM SUB PANEL MAINB  BREAKER PANEL  SCHEDULE #ESTAMP 20 15 20 20 15 20 20 15 20 LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES LIGHTS/RECEPTACLES PV-4.4 1312 S Hickory St 5/5/2025 FACILITY  GROUND 120/240 VAC SINGLE PHASE SERVICE EXISTING 200A MAIN BREAKER  CENTER FED EXISTING 200A MAIN PANEL 200A  BUS M TESLA  BACKUP  SWITCH 70A UL 9540  FACTORY WIRING  ASSEMBLY (1 ) TESLA POWERWALL 3 EXPANSION PACK 1807000-XX-Y TESLA POWERWALL 3 1707000-XX-Y POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 J-BOX SILFAB SIL-420QD STRING 1 OF 8 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES 12  LOAD BREAKER AT EITHER END OF A  CENTER-FED PANELBOARD 222013-106356  = 80A USED FOR INTERCONNECTION CALCULATIONS J-BOX 18 Canadian Solar Inc.:  CS1H-325MS EE Existing SolarEdge Technologies: SE3800H-USE Existing Inverter(s) E AC DISCONNECT E EXISTING SYSTEM E 20A OCPD (N)LOAD  CENTER 125A  4 (1) 60A PV & ESS  BREAKER  60A  (E) 20A PV   BREAKER  (N)TESLA REMOTE METER (1)SOLAR PV CURRENT TRANSFORMER (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 PV-4.0 ELECTRICAL #ESTAMP 1312 S Hickory St 5/5/2025 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG  (PV WIRE)N/A 6 AWG  (BARE)Open Air 2 Inverter Input (2) 10 AWG  THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Load Center (2) 4 AWG  THHN/THWN-2 (1) 4 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT E EXISTING PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 #ESTAMP PV-4.1 ELECTRICAL CONT. POWER CONTROL SYSTEM (PCS): SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. WITH 240.6(C).  SETPOINTS:           - 56A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL           - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) General Notes: COLD WATER GAS BOND 1312 S Hickory St 5/5/2025 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 Inverter Calculations Each Inverter has the following values which are calculated following these formulas: Inverter X: Load)(690.8(B)(1)) [((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc * (# Modules / String) Inverter Powerwall 3 1707000-xx-y Wire Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit Conductors use the ampacity in the 75°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current Inverter Overcurrent Protection:    (Inverter(s) Max Combined Current) x (Continous Load) =    48 A x 1.25 + 20A = 80 A → 70 A Overcurrent Protection Using PCS Allowable Backfeed  Max Allowed Total Generation Backfeed OCPD = Main Breaker Rating = 200A  70 A ≤ 200A → Interconnection meets CEC 2022: 705.13 requirements. PV-4.2 ELECTRICAL CALCS 1312 S Hickory St 5/5/2025 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL DEMAND  LOAD 1 20A-1P LIGHTS/RECEPTACLES 1500 W 2 15A-1P LIGHTS/RECEPTACLES 1500 W 3 20A-1P LIGHTS/RECEPTACLES 1500 W 4 20A-1P LIGHTS/RECEPTACLES 1500 W 5 15A-1P LIGHTS/RECEPTACLES 1500 W 6 20A-1P LIGHTS/RECEPTACLES 1500 W 7 20A-1P LIGHTS/RECEPTACLES 1500 W 8 15A-1P LIGHTS/RECEPTACLES 1500 W 9 20A-1P LIGHTS/RECEPTACLES 1500 W 10 100A-2P SUB PANEL 19200 W 11 20A-2P TRM 720 W PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 PV-4.3 BACKUP  LOADS 1312 S Hickory St 5/5/2025 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 SIGNAGE PV-5.0 #ESTAMP SOLAR PANELS ON ROOF NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): NEC 706.15(C), CEC 706.15(C) 120/240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE  REQUIREMENTS OF THE CEC 2022 ARTICLE  110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE  REQUIRED BY SECTION 690, OR IF REQUESTED BY  THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF  HAZARDS USING EFFECTIVE WORDS, COLORS  AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE  EQUIPMENT OR WIRING METHOD AND SHALL NOT  BE HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO  WITHSTAND THE ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI  Z535.4-2011, PRODUCT SAFETY SIGNS AND  LABELS, UNLESS OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER  LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) THIS EQUIPMENT FED BY  MULTIPLE SOURCES. TOTAL  RATING OF ALL OVERCURRENT  DEVICES EXCLUDING MAIN  SUPPLY OVERCURRENT DEVICE  SHALL NOT EXCEED AMPACITY OF  BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND  ANY PANEL THAT UTILIZES "THE SUM  OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3),  CEC 2022: 705.12 (B)(3)(3) PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 CAUTION  1312 S HICKORY ST, SANTA ANA, CA, 92707 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER (E) PV ARRAY PV SYSTEM(S) ARE EQUIPPED WITH  RAPID SHUTDOWN DEVICE(S) RAPID SHUTDOWN DISCONNECT LOCATION  (EXISTING SYSTEM AC DISCONNECT) (E) PV EQUIPMENT LOAD CENTER SERVICE ENTRANCE WITH TESLA  BACKUP SWITCH INVERTER + ENERGY STORAGE  (EXT) - PCS CONTROLLED EXPANSION PACK (EXT) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT 1312 S Hickory St 5/5/2025 PAGE REV: A 3/7/2025 THEODORE ARROYOS 1312 S HICKORY ST, SANTA  ANA, CA, 92707 PROJECT NUMBER:   109R-131ARRO SHEET DESIGNER: VIPIN YADAV CUSTOMER RESIDENCE: TEL. (714) 747-5758 APN: 014-203-25 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 SIGNAGE PV-5.1 #ESTAMP NO ADDITIONAL LOADS  TO BE ADDED LABEL LOCATION: BACKED UP LOADS PANEL WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE  BY CLAMP SIZE 4.25" X 0.75" INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING:  56A   THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. ONLY THIS INVERTER HAS  RAPID SHUT DOWN 1312 S Hickory St 5/5/2025 Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing up to 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads rated up to 185 LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 Expansions make it easier and more affordable to scale up customers’ systems to meet their current or future needs.Powerwall 3 is designed for fast and ef cient installations,modular system expansion,and simple connection to any electrical service. 22024Powerwall 3 Datasheet Powerwall 3 Technical Specifications System Technical Speci cations Model Number 1707000-xx-y Nominal Grid Voltage (Input & Output)120/240 VAC Grid Type Split phase Frequency 60 Hz Nominal Battery Energy 13.5 kWh AC 1 Nominal Output Power (AC)5.8 kW 7.6 kW 10 kW 11.5 kW Maximum Apparent Power 5,800 VA 7,600 VA 10,000 VA 11,500 VA Maximum Continuous Current 24 A 31.7 A 41.7 A 48 A Overcurrent Protection Device 2 30 A 40 A 60 A 60 A Con gurable Maximum Continuous Discharge Power Off-Grid (PV Only, -20°C to 25°C) 15.4 kW 3 Maximum Continuous Charge Current / Power (Powerwall 3 only) 20.8 A AC / 5 kW Maximum Continuous Charge Current / Power (Powerwall 3 with up to (3) Expansion units) 33.3 A AC / 8 kW Output Power Factor Rating 0 -1 (Grid Code con gurable) Maximum Output Fault Current (1 s)160 A Maximum Short-Circuit Current Rating 10 kA Load Start Capability 185 LRA Solar to Battery to Home/Grid Ef ciency 89% 1,4 Solar to Home/Grid Ef ciency 97.5% 5 Power Scalability Up to 4 Powerwall 3 units supported Energy Scalability Up to 3 Expansion units (for a maximum total of 7 units) Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz),Ethernet,Cellular (LTE/4G 6) Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certi ed switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/-0.5%,ANSI C12.20) Protections Integrated arc fault circuit interrupter (AFCI),Isolation Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years 1 Values provided for 25°C (77°F),at beginning of life.3.3 kW charge/discharge power. 2 See Powerwall 3 Installation Manual for fuse requirements if using fuse for overcurrent protection. 3 15.4kW off-grid maximum continuous discharge power is only available if on-grid rating is 11.5 kW. If enabled, Powerwall 3 must be installed with an 80 A breaker and appropriately sized conductors. 4 Typical solar shifting use case. 5 Tested using CEC weighted ef ciency methodology. 6 The customer is expected to provide internet connectivity for Powerwall 3; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 1312 S Hickory St 5/5/2025 32024Powerwall 3 Datasheet Powerwall 3 Technical Specifications Environmental Speci cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 9 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F),up to 95%RH,non- condensing,State of Energy (SOE):25%initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 (Battery &Power Electronics) IP55 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m <50 db(A)typical <62 db(A)maximum 9 Performance may be de-rated at operating temperatures above 40°C (104°F). Compliance Information Certi cations UL 1741, UL 9540, UL 9540A, UL 3741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 1699B, UL 1998, CSA C22.2 No. 0.8, CSA C22.2 No. 107.1, CSA C22.2 No. 330, CSA 22.3 No. 9, IEEE 1547, IEEE 1547A, IEEE 1547.1, CA Rule No.21 Grid Connection United States and Canada Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156,IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A Solar Technical Speci cations Maximum Solar STC Input 20 kW Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (I mp)15 A 7, 8 Maximum Short Circuit Current per MPPT (Isc)19 A 8 7 Only applicable to Powerwall 3 units with 15 A IMP on the product label. Otherwise, Powerwall 3 has an IMP of 13 A. 8 When PV strings are combined on the roof and the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs into a single input to intake DC current up to 30 A IMP / 38 A ISC (or 26 A IMP / 30 A ISC if Powerwall 3 is labeled with 13 A IMP / 15 A ISC). 42024Powerwall 3 Datasheet Mechanical Speci cations Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in) 10 Total Weight of Installed Unit 132 kg (291.2 lb) Weight of Powerwall 3 124 kg (272.5 lb) Weight of Glass Front Cover 6.5 kg (14.5 lb) Weight of Wall Bracket 1.9 kg (4.2 lb) Mounting Options Floor or wall mount 609 mm 193 mm 1105 mm 10 These dimensions include the glass front cover being installed on Powerwall 3. Powerwall 3 Technical Specifications 1312 S Hickory St 5/5/2025 52024Powerwall 3 Datasheet Powerwall 3 Expansion Technical Specifications Environmental Speci cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 12 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F),up to 95%RH,non- condensing,State of Energy (SOE):25%initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 Pollution Rating PD3 Compliance Information Certi cations UL 1973, UL 9540 12 Performance may be de-rated at operating temperatures above 40°C (104°F). Battery Technical Speci cations Model Number 1807000-xx-y Nominal Battery Energy 13.5 kWh Voltage Range 52 - 92 V DC 11 11 Powerwall 3 Expansion units are connected in parallel and are not eld serviceable. Mechanical Speci cations Dimensions 1105 x 609 x 168 mm (43.5 x 24 x 6.6 in) 13 Total Weight of Wall- Mounted Expansion Unit 118.5 kg (261.2 lb) Weight of Expansion Unit 110 kg (242.5 lb) Weight of Glass Front Cover 6.5 kg (14.5 lb) Weight of Wall Bracket 1.9 kg (4.2 lb) Weight of Expansion Accessories 0.7 kg (1.5 lb) Mounting Options Floor or wall mount Stacking Capability (Floor Mount Only) Up to (3)Expansion units behind a Powerwall 3 Compatibility with Other Systems Only compatible with Powerwall 3 Connection to Powerwall 3 or Expansions Powerwall 3 Expansion harness 14 14 The Powerwall 3 Expansion harness is a listed component of the UL 9540 certi cation. 13 These dimensions include the glass front cover being installed on Powerwall 3 Expansion. 609 mm 168 mm 1105 mm 62024Powerwall 3 Datasheet Electrical Speci cations Model MCI-1 MCI-2 MCI-2 High Current Nominal Input DC Current Rating (IMP)13 A 13 A 15 A Maximum Input Short Circuit Current (ISC)19 A 17 A 19 A Maximum System Voltage 600 V DC 1000 V DC 15 1000 V DC 15 Maximum Disconnect Voltage 16 600 V DC 165 V DC 165 V DC Solar Shutdown Device Technical Specifications Environmental Speci cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X / IP65 RSD Module Performance Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is integral to the rapid shutdown (RSD)function required for rooftop PV systems in accordance with Article 690 of the NEC. When paired with Powerwall 3, solar array shutdown is initiated by an External System Shutdown Switch or the On/Off Enable switch located on Powerwall 3. Systems not subject to rapid shutdown requirements must still install one or more MCIs for functional purposes; see the Powerwall 3 installation manual for details. Mechanical Speci cations Electrical Connections MC4 Connector Housing Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip Compliance Information Certi cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 15 Maximum System Voltage is limited by Powerwall to 600 V DC. 16 Maximum Disconnect Voltage is the maximum voltage allowed across each MCI in the open position (Rapid Shutdown Initiated).An individual MCI-2 has a voltage rating of 165V but in combination (connected in the same string)their voltage ratings are additive. UL 3741 PV Hazard Control (and PVRSA) Compatibility See UL 3741 Application Addendum 1312 S Hickory St 5/5/2025 52024Powerwall 3 Datasheet Powerwall 3 Expansion Technical Specifications Environmental Speci cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 12 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F),up to 95%RH,non- condensing,State of Energy (SOE):25%initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 Pollution Rating PD3 Compliance Information Certi cations UL 1973, UL 9540 12 Performance may be de-rated at operating temperatures above 40°C (104°F). Battery Technical Speci cations Model Number 1807000-xx-y Nominal Battery Energy 13.5 kWh Voltage Range 52 - 92 V DC 11 11 Powerwall 3 Expansion units are connected in parallel and are not eld serviceable. Mechanical Speci cations Dimensions 1105 x 609 x 168 mm (43.5 x 24 x 6.6 in) 13 Total Weight of Wall- Mounted Expansion Unit 118.5 kg (261.2 lb) Weight of Expansion Unit 110 kg (242.5 lb) Weight of Glass Front Cover 6.5 kg (14.5 lb) Weight of Wall Bracket 1.9 kg (4.2 lb) Weight of Expansion Accessories 0.7 kg (1.5 lb) Mounting Options Floor or wall mount Stacking Capability (Floor Mount Only) Up to (3)Expansion units behind a Powerwall 3 Compatibility with Other Systems Only compatible with Powerwall 3 Connection to Powerwall 3 or Expansions Powerwall 3 Expansion harness 14 14 The Powerwall 3 Expansion harness is a listed component of the UL 9540 certi cation. 13 These dimensions include the glass front cover being installed on Powerwall 3 Expansion. 609 mm 168 mm 1105 mm 62024Powerwall 3 Datasheet Electrical Speci cations Model MCI-1 MCI-2 MCI-2 High Current Nominal Input DC Current Rating (IMP)13 A 13 A 15 A Maximum Input Short Circuit Current (ISC)19 A 17 A 19 A Maximum System Voltage 600 V DC 1000 V DC 15 1000 V DC 15 Maximum Disconnect Voltage 16 600 V DC 165 V DC 165 V DC Solar Shutdown Device Technical Specifications Environmental Speci cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X / IP65 RSD Module Performance Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is integral to the rapid shutdown (RSD)function required for rooftop PV systems in accordance with Article 690 of the NEC. When paired with Powerwall 3, solar array shutdown is initiated by an External System Shutdown Switch or the On/Off Enable switch located on Powerwall 3. Systems not subject to rapid shutdown requirements must still install one or more MCIs for functional purposes; see the Powerwall 3 installation manual for details. Mechanical Speci cations Electrical Connections MC4 Connector Housing Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip Compliance Information Certi cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 15 Maximum System Voltage is limited by Powerwall to 600 V DC. 16 Maximum Disconnect Voltage is the maximum voltage allowed across each MCI in the open position (Rapid Shutdown Initiated).An individual MCI-2 has a voltage rating of 165V but in combination (connected in the same string)their voltage ratings are additive. UL 3741 PV Hazard Control (and PVRSA) Compatibility See UL 3741 Application Addendum 1312 S Hickory St 5/5/2025 92024Powerwall 3 Datasheet Backup Gateway 2 Performance Speci cations Model Number 1232100-xx-y AC Voltage (Nominal)120/240 V Feed-in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short Circuit Current 10 kA 20 Overcurrent Protection Device 100 - 200 A, Service entrance rated Overvoltage Category Category IV Mechanical Speci cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-Bush mount Environmental Speci cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, Class B, ICES 003 411 mm 660 mm 149 mm 20 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. In this system con guration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled. Internal Primary AC Meter +/- 0.2% Internal Auxiliary AC Meter +/- 2% Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 102024Powerwall 3 Datasheet Powerwall 3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup 1312 S Hickory St 5/5/2025 112024Powerwall 3 Datasheet Backup Switch Load center Backup loads SolarSolar Grid Meter Meter socket panel Generation panel SolarSolar SolarSolar SolarSolar Powerwall 3 Powerwall 3 Expansion Powerwall 3 Powerwall 3 Powerwall 3 Powerwall 3 Expansion Powerwall 3 Expansion Powerwall 3 Expansion Load center Backup loads SolarSolar Grid Meter Meter socket panel Gateway 3 Powerwall 3 Powerwall 3 Expansion Powerwall 3 Expansion Powerwall 3 Expansion Powerwall 3 with Backup Switch (4) Powerwall 3 Units with (3) Expansion Units (Maximum System Size) Powerwall 3 with Gateway 3 (1) Powerwall 3 with (3) Expansion Units Powerwall 3 Example System Configurations 1312 S Hickory St 5/5/2025 Product datasheet Characteristics HOM1224L125PRB Main Product or component type Load Center Range of product Homeline Load center type Main lugs Line Rated Current 125 A Number of spaces 12 Number of circuits 24 NEMA degree of protection NEMA 3R outdoor Cover type Surface cover Electrical connection Lugs Complementary Short-circuit current 10 kA Number of tandem circuit breakers 12 Phase 1 phase System Voltage 120/240 V AC WG gauge WG 6...AWG 2/0 (aluminium) WG 6...AWG 1 (copper) Wiring configuration 3-wire Cover finish Gray baked enamel Material Tin plated aluminium busbar Enclosure material Welded galvannealed steel Surface finish Baked enamel grey Box number 3R Height 29.84 in (758 mm) Width 14.76 in (375 mm) Depth 4.53 in (115 mm) Environment product certifications UL E-6294 Offer Sustainability Green Premium product Green Premium product Compliant - since 1414 - Schneider Electric declaration of conformity Compliant - since 1414 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold vailable vailable Need no specific recycling operations Need no specific recycling operations WARNING: This product can expose you to chemicals including: WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm. Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov Th e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d / o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n . Th i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s . It i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f th e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . 1 / 1 1312 S Hickory St 5/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] 1312 S Hickory St 5/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 4 1.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) 1312 S Hickory St 5/5/2025 SIL-420/430 QD S I L FA B S O L A R . CO M • Improved Shade Tolerance • Improved Low-Light Performance • Increased Performance in High Temperatures • Enhanced Durability • Reduced Degradation Rate • Industry-Leading Warranty I N T R O D U C I N G N E X T- G E N E R A T I O N N -T Y P E C E L L T E C H N O LO G Y NTC MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 21 kg ± 0.2 kg 46.3 lbs ± 0.4 lbs Dimensions (H x L x D) 1721 mm x 1133 mm x 35 mm 67.8 in x 44.6 in x 1.37 in Maximum surface load (wind/snow)* 4000 Pa rear load / 5400 Pa front load 83.5 lb/2 rear load / 112.8 lb/2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 108 Half cells - N-Type Silicon solar cell 182 mm x 91 mm 108 Half cells - N-Type Silicon solar cell 7.16 in x 3.58 in Glass 3.2 mm high transmittance, tempered, antireflective coating 0.126 in high transmittance, tempered, antireflective coating Cables and connectors (refer to installation manual) 1350 mm, ø 5.7 mm, MC4 from Staubli 53.1 in, ø 0.22 in (12 AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized aluminum (Black) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated, 3 diodes TEMPERATURE RATINGS Temperature Coe icient Isc 0.04 %/°C Temperature Coe icient Voc -0.24 %/°C Temperature Coe icient Pmax -0.29 %/°C NOCT (± 2 °C) 45 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 98% end 1st yr ≥ 94.7% end 12th yr ≥ 90.8% end 25th yr ≥ 89.3% end 30th yr SHIPPING SPECS Modules Per Pallet: 26 or 26 (California) Pallets Per Truck 32 or 30 (California) Modules Per Truck 832 or 780 (California) CERTIFICATIONS Product UL 61215, UL 61730, CSA C22.2#61730, IEC 61215, IEC 61730, IEC 61701 (Salt Mist Corrosion), IEC 62716 (Ammonia Corrosion), CEC Listed, UL Fire Rating: Type 2 Factory ISO9001:2015 * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. 44 . 6 " [ 1 1 3 3 m m ] 11.8" [300.5mm]44.1" [1120mm]11.8" [300.5mm] Ø0 . 1 7 " [ Ø 4 . 2 m m ] ( x 2 ) Gr o u n d i n g H o l e Mounting Hole (x4) Drainage Hole (x8) 43 " [ 1 0 9 3 m m ] 2.4" [60mm]8" [200mm] 53.15" [1350mm] Cable Length 1.4" [35mm] 1. 4 " [ 3 5 m m ] 0.06" [1.5mm] 67.8" [1721mm] 1. 4 " [ 3 5 m m ] 0.5" [12mm] 0. 3 " [ 7 m m ] 0. 6 " [ 1 5 m m ] Si d e Ba c k V i e w Pr o f i l e ELECTRICAL SPECIFICATIONS 420 430 Test Conditions STC NOCT STC NOCT Module Power (Pmax) Wp 420 313 430 321 Maximum power voltage (Vpmax) V 33.08 30.86 33.25 31.02 Maximum power current (Ipmax) A 12.70 10.15 12.93 10.33 Open circuit voltage (Voc) V 38.84 36.52 38.91 36.58 Short circuit current (Isc) A 13.50 10.85 13.87 11.15 Module e iciency % 21.5% 20.1% 22.1% 20.6% Maximum system voltage (VDC) V 1000 Series fuse rating A 25 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m • AM 1.5 • Temperature 25 °C • NOCT 800 W/m • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10 W. 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 info@silfabsolar.com S I L FA B S OL AR . C O M 7149 Logistics Lane Fort Mill SC 29715 USA T +1 839.400.4338 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-420/430-QD-20240227 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2022. Silfab Solar® is a registered trademark of Silfab Solar Inc. SILFAB SOLAR INC. 1312 S Hickory St 5/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547- 2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547- 2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547- 2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547- 2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B HIGH FREQUENCY RIDE- THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547- 2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547- 2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547- 2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547- 2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547- 2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547- 2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547- 2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547- 2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547- 2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547- 2018 VOLTAGE-ACTIVE POWER (VOLT- WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547- 2018 TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547- 2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547- 2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547- 2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547- 2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547- 2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547- 2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547- 2018 1312 S Hickory St 5/5/2025 1312 S Hickory St 5/5/2025 Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production,fast and ef𿿿cient installations,easy system expansion,and simple connection to any electrical service. 22024Powerwall 3 Datasheet Solar Technical Speci￿cations Maximum Solar STC Input 20 kW Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (Imp)13 A 5 Maximum Short Circuit Current per MPPT (Isc)15 A 5 Powerwall 3 Technical Specifications 1 Typical solar shifting use case. 2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. 3 Tested using CEC weighted ef𿿿ciency methodology. 4 The customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A ISC. Battery Technical Speci￿cations Nominal Battery Energy 13.5 kWh AC 2 Maximum Continuous Discharge Power 11.5 kW AC Maximum Continuous Charge Power 5 kW AC Output Power Factor Rating 0 -1 (Grid Code con𿿿gurable) Maximum Continuous Current 48 A Maximum Output Fault Current 10 kA Load Start Capability (1 s)185 A LRA Power Scalability Up to 4 Powerwall 3 units supported System Technical Speci￿cations Model Number 1707000-xx-y Nominal Grid Voltage (Input &Output)120/240 VAC Grid Type Split phase Frequency 60 Hz Overcurrent Protection Device 60 A Solar to Battery to Home/Grid Ef￿ciency 89% 1,2 Solar to Home/Grid Ef￿ciency 97.5% 3 Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4) Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certi𿿿ed switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years 1312 S Hickory St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eb 3, 2020 : !!761;!: ;: ;:  , 3 4 3 <) =2::5,3< 2#15()<==  . )( *C . */3.%D //  . )( *  . )( //    . --8  (/. 88  .#1 $+  8  . E8 *  - ( .(.3+  .( -8. 4   ,.4.   / (/.     .3 .A 8 '  -2- ./- .3 44428#14 ..3 2 23' $  3( .$  (  . $ / /"C   ' -8( .  (  . E '*- (/ C % */ C  E -8 ../- .C  .  3( . .  (  .   '  .  (  .< / . ( 3 ( 8 = .'.- . ( (   .'.- . (/( (  */( . / 8 / *(.38  . .    (4  . *   . *:6-.  1312 S Hickory St 5/5/2025 32024Powerwall 3 Datasheet Mechanical Speci￿cations Dimensions 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) Weight 130 kg (287 lb) Mounting Options Floor or wall mount Powerwall 3 Technical Specifications Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m < 50 db(A) typical <62 db(A)maximum Compliance Information Certi￿cations UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 193 mm 1099 mm 42024Powerwall 3 Datasheet Electrical Speci￿cations Model MCI-1 MCI-2 Nominal Input DC Current Rating (IMP)13 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Speci￿cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X /IP65 NEMA 4X /IP65 RSD Module Performance Maximum Number of Devices per String 5 5 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Speci￿cations Electrical Connections MC4 Connector MC4 Connector Housing Plastic Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip Compliance Information Certi￿cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 7 Maximum System Voltage is limited by Powerwall to 600 V DC. UL 3741 PV Hazard Control (and PVRSA)Compatibility See Powerwall 3 Installation Manual 1312 S Hickory St 5/5/2025 52024Powerwall 3 Datasheet Gateway 3 8 Only Eaton CSR or BWH main breakers are 25 kA rated. Performance Speci￿cations Model Number 1841000-01-y Nominal Grid Voltage 120/240 V AC Grid Con￿guration Split phase Grid Frequency 60 Hz Continuous Current Rating 200 A Maximum Supply Short Circuit Current 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker 8 IEC Protective Class Class I Overvoltage Category Category IV Mechanical Speci￿cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 16.3 kg (36 lb) Mounting options Wall mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 107.1, CSA 22.2 29 Emissions FCC Part 15, ICES 003 — Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based control, and backup operation. 411 mm 660 mm 149 mm AC Meter Revenue accurate (+/- 0.5%) Communication CAN User Interface Tesla App Backup Transition Automatic disconnect for seamless backup Overcurrent Protection Device 100–200 A Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers Internal Panelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or Square D HOM breakers rated to 10–125A Warranty 10 years 62024Powerwall 3 Datasheet Backup Switch 9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Performance Speci￿cations Model Number 1624171-xx-y Continuous Load Rating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 9 Communication CAN AC Meter Revenue accurate (+/- 0.5%) Expected Service Life 21 years Warranty 10 years Mechanical Speci￿cations Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) Weight 2.8 lb Meter and Socket Compatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override 10 Reset button Conduit Compatibility 1/2-inch NPT Environmental Speci￿cations Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) Enclosure Rating NEMA 3R Pollution Rating PD3 Compliance Information Safety Standards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 Emissions FCC, ICES 10 Manually overrides the contactor position during a service event. — The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 204.86 74 176 mm 205 mm 74 mm 1312 S Hickory St 5/5/2025 72024Powerwall 3 Datasheet Backup Gateway 2 Performance Speci￿cations Model Number 1232100-xx-y AC Voltage (Nominal)120/240 V Feed-in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short Circuit Current 10 kA 11 Overcurrent Protection Device 100 - 200 A, Service entrance rated 9 Overvoltage Category Category IV Internal Primary AC Meter Revenue accurate (+/- 0.2%) Internal Auxiliary AC Meter Revenue accurate (+/- 2%) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G) 12 Mechanical Speci￿cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-Bush mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 411 mm 660 mm 149 mm 11 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 12 Cellular connectivity subject to network operator service coverage and signal strength. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. In this system con𿿿guration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled. User Interface Tesla App Operating Modes Support for solar self- consumption, time-based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 82024Powerwall 3 Datasheet Powerwall 3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup 1312 S Hickory St 5/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 1312 S Hickory St 5/5/2025 STRUCTURAL CERTIFICATION REPORT Roof-mounted Solar Panels March 07, 2025 To: Sunrun Re: Theodore Arroyos 1800 Ashton Blvd 1312 S Hickory St Lehi, UT 84043 Santa Ana, CA 92707 AHJ: Santa Ana (City), CA Sunrun proposes to install new roof-mounted solar panels at this residence and asked Right Angle Engineering to review the existing structure for suitability. This letter summarizes the methods that were used to survey, evaluate, and certify the existing roof framing and the attachment of the new solar panels to it. STRUCTURAL DESIGN Building Code:California Residential Code 2022 Design Standards:ASCE 7-16 Snow:Ground: pg= 0.0 psf | Flat Roof: pf= 0.0 psf | Sloped Roof: ps= 0.0 psf Wind:Ultimate Wind Speed = 96.0 mph | Exposure = C Seismic:Risk Category = 2 | Seismic Design Category = A | Site Class = D STRUCTURE Field Technicians from Sunrun visited the site and observed the existing structure : Array Name Panel Quantity Roof Framing Material Pitch Array 1 8 2x6 Rafter| 16" o.c.Asphalt Shingles 10° ANCHORAGE The solar panel anchorage shall be installed according to the manufacturer's most current installation manual. The attachment configuration should match the certified building plans. The solar panels should be mounted parallel (max 5 inches) to the roof surface. Array Name Connection Type Fastener Max Anchorage Spacing Array 1 Umbrella L-Foot 5/16” lag screw (2.5" embedment) into roof substructure 64" Installation Instructions Solar panels and the equipment shall be installed per the manufacturer's installation specifications. Improper installation will void this certification. If deviations from the approved structural plans occur, Right Angle Engineering must be notified. Prior to installation, the installer should: Confirm that the existing structure matches the information provided in the site survey, the approved installation plans and this certification. Identify discrepancies between this certification and the approved installation plans. If found, then this certification shall govern. Identify structural elements that are dangerous (cracked, broken, excessive sag, signs of overstress, rot, decay, fire, water). If found, installation shall cease until those elements are adequately abated and made to comply with the referenced building code. Verify that both the existing structure and the solar addition has been permitted through the AHJ. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 1 of 6 1312 S Hickory St 5/5/2025 STRUCTURAL CERTIFICATION I certify the addition of solar panels on the roof of this structure does not cause the structure to become unsafe or make it generally less compliant with the life-safety requirements of the referenced building code. Based on the evaluation methods described below, for the loads that exist at this site, the existing framing will safely support the new solar panels if they are installed and attached correctly. Electrical design is not included in this certification. Array Name Certification Method Retrofits Array 1 Stress analysis California Residential code 324.4.1 None required Regards, 03/07/2025 Robert D. Smythe, P.E. Right Angle Engineering 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 2 of 6 1312 S Hickory St 5/5/2025 Job Details Roof Snow Load - ASCE 7-16 Ground Snow Load (pg) Section 7.2 0.0 psf Exposure Factor (Ce) Table 7.3-1 0.9 Thermal Factor (Ct) Table 7.3-2 1.1 Importance Factor (Is) Table 1.5-2 1 Flat Roof Snow Load (pƒ) Equation 7.3-1 0.0 psf Non-Slippery Surface Slope Factor (Cs) Figure 7.4-1 1 Slippery Surface Slope Factor (Cs) Figure 7.4-1 1 Roof Snow Load Equation 7.4-1 0.0 psf Reduced Snow Load (Slippery Surface) Equation 7.4-1 0.0 psf Design Criteria Wind Speed (Vult) Local Design Criteria 96.0mph Exposure Category C Risk Category 2 Mean Roof Height 20 ft Roof Type Gable Roof Building Type Enclosed Roof Live Load Existing Roof Live Load ASCE 7-16 Table 4.3-1 20 psf 1Roof Dead Load Asphalt Shingles 2.0 psf No Drywall 0.0 psf 5/8" Plywood Sheathing 2.0 psf Solar Panel Array 2.74 psf Roof Framing 2.36 psf Dead Load Without Panels 7.56 psf Insulation 1.2 psf 1Roof Dead Load is taken from the worst case scenario dead load from all arrays of the job in order to provide a more conservative evaluation. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 3 of 6 1312 S Hickory St 5/5/2025 Array 1 Array Details Roof Framing 2x6 Rafter DF No.2 Spacing 16.0" Beam Span 15.0' Roof Pitch 10° Solar Rails UR-40 Panel Quantity 8 Panel Array Area 173.08 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type Umbrella L-Foot 5/16” lag screw Shear Capacity NDS 2015 Table 12K 190.0 lbs Pullout Capacity NDS 2015 Table 12K 665.0 lbs Velocity Pressure Equation 26.10-1 (Kz=0.9, Kht=1, Kd=0.85, Ke=1.0) 15.59 psf GCP Zones 1/2e 2n/2r /3e 3r GCp Figure 30.3-(2A-5B)-1.93 -2.52 -3.0 Design Pressure Up [psf] Equation 29.4-7 ga=0.53 gE=1.0,-16.0 -20.9 -24.9 Factored Design Pressure Up [psf] ASD LC (.6D + .6W) -8.0 -10.9 -13.3 Exposed Design Pressure Up [psf] ga=0.53 gE=1.5, -24.0 -31.4 -37.4 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]83.3 60.8 49.9 Maximum Connection Spacing [in]319 233 192 Maximum Rail Span [in]80 80 77 Maximum Rail Cantilever [in]21 21 21 Design Connection Spacing [in] *Adjusted 64 64 64 Design Connection Spacing (exposed) [in]64 64 64 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 4 of 6 1312 S Hickory St 5/5/2025 Design Ratio Member ID Axial Momentz Sheary Combined Slenderness Deflection Status 1 0.005 0.485 0.162 0.49 0.044 0.276 Pass 2 0.001 0.036 0.044 0.037 0.044 0.423 Pass Member Design Capacity (LRFD) Member ID FI b(ksi)FI t(ksi)FI v(ksi)FI c(ksi)FI cp(ksi)EI(ksi)Emin I(ksi) 1 2.324 1.292 0.311 2.566 0.939 1600.0 1041.216 2 2.324 1.292 0.311 2.566 0.939 1600.0 1041.216 Node Coordinates ID X Coordinate Y Coordinate 1 0.000 0.000 2 15.000 2.645 3 -1.500 -0.264 Members ID Node A Node B Section Node A Fixity Node B Fixity Length 1 1 2 1 FFFFFF FFFFFF 15.231 2 3 1 1 FFFFFF FFFFFF 1.523 Supports ID Node ID Restraint Code 1 2 RFFRRR 2 1 FFFFFR Materials ID Name Young's Modulus Density Poisson's Ratio 1 NDS - Table 4A - DOUGLAS FIR-LARCH - No.2- 2in & wider 1600.000 33.308 0.400 Sections ID Name Depth Width Shear Area Z Shear Area Y Torsion Radius 1 1.5 x 5.5 6.000 1.500 7.502 7.500 1.495 ID Centroid Y Centroid Z Area Y-Axis Mol Z-Axis Mol Torsion Constant 1 0.750 3.000 9.000 1.688 27.000 5.687 Point Loads ID Load Group Member Position %Y Magnitude 1 Solar-Snow 1 30.000%0.000 2 Solar 1 30.000%-0.030 Member Distributed Loads ID Load Group Start Position End Position Member Y Magnitude 1 Dead Load 0.000%100.000%2 -0.010 2 Dead Load 0.000%100.000%1 -0.010 3 Roof Live Load 0.000%100.000%2 -0.027 4 Roof Live Load 0.000%23.333%1 -0.027 5 Roof Live Load 64.410%100.000%1 -0.027 6 Snow Load 0.000%100.000%2 0.000 7 Snow Load 0.000%23.333%1 0.000 8 Snow Load 64.410%100.000%1 0.000 Load Combinations ID Name Dead Load Factor Snow Load Factor Solar Factor Solar-Snow Factor Roof Live Load Factor 1 1. 1.4D 1.4 0 1.4 0 0 2 3. 1.2D + 1.6Lr 1.2 0 1.2 0 1.6 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 5 of 6 1312 S Hickory St 5/5/2025 3 3. 1.2D + 1.6S 1.2 1.6 1.2 1.6 0 4 4. service loads A 0 1 0 1 0 5 5. service loads B 0 0 0 0 1 Internal Member Forces and Moments Member Axial Force (Min/Max) Shear Force Y (Min/Max) Shear Force Z (Min/Max) Torsion (Min/Max) Bending Moment Y (Min/Max) Bending Moment Z (Min/Max) 1 -0.053 / 0.051 -0.302 / 0.292 0.000 / 0.000 0.000 / 0.000 0.000 / 0.000 -0.063 / 0.846 2 -0.014 / 0.000 -0.082 / 0.000 0.000 / 0.000 0.000 / 0.000 0.000 / 0.000 -0.063 / 0.000 Member Displacement Span Check Member Length Max Relative Displacement Span Method 1 1 15.231 0.280 L/652 2 1.523 0.086 L/213 Member Stresses Member Axial Stress (Min/Max) Torsion Stress (Min/Max) Shear Stress Y (Min/Max) Shear Stress Z (Min/Max) Top Bending Moment Z (Min/Max) Bottom Bending Moment Z (Min/Max) 1 -0.006 / 0.006 0.000 / 0.000 -0.050 / 0.049 -0.000 / -0.000 -0.083 / 1.128 -1.128 / 0.083 2 -0.002 / 0.000 0.000 / 0.000 -0.014 / 0.000 0.000 / 0.000 -0.083 / 0.000 0.000 / 0.083 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 6 of 6 1312 S Hickory St 5/5/2025 City of Santa Ana, I, Theodore Arroyos, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar on my residence located at 1312 s hickory st , SANTA ANA, CA, 92707. SIGNATURE:___________________ DATE:__________ 717 17th Street, Ste. 200 | Denver, CO 80202  Docusign Envelope ID: BE41ABB4-1960-493B-98B7-E24D8CC27BB0 3/31/2025 1312 S Hickory St 5/5/2025 Certificate Of Completion Envelope Id: BE41ABB4-1960-493B-98B7-E24D8CC27BB0 Status: Completed Subject: Sunrun needed for permits URGENT Complete with Docusign: Solar Authorization Letter.pdf EmployeeName: TermDate: Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Bobby Cautela AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 robert.cautela@sunrun.com IP Address: 174.65.135.37 Record Tracking Status: Original 3/31/2025 11:24:45 AM Holder: Bobby Cautela robert.cautela@sunrun.com Location: DocuSign Signer Events Signature Timestamp Theodore Arroyos papitas1997@yahoo.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 99.9.59.21 Signed using mobile Sent: 3/31/2025 11:25:45 AM Viewed: 3/31/2025 12:20:28 PM Signed: 3/31/2025 12:21:06 PM Electronic Record and Signature Disclosure: Accepted: 2/14/2025 3:18:25 PM ID: c8264e9b-e612-4b7a-a37c-793e4dc4759c In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 3/31/2025 11:25:45 AM Certified Delivered Security Checked 3/31/2025 12:20:28 PM Signing Complete Security Checked 3/31/2025 12:21:06 PM Completed Security Checked 3/31/2025 12:21:06 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure 1312 S Hickory St 5/5/2025 CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Theodore Arroyos 1312 S Hickory St 5/5/2025 How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X 1312 S Hickory St 5/5/2025 Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute 1312 S Hickory St 5/5/2025 the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. 1312 S Hickory St 5/5/2025 Article 220 - Service/Feeder calculation for (address):Job Code 1312 S Hickory St Santa Ana CA USA 92707 109R-131ARRO Section 220.83 Existing Dwelling Unit Part #1 - Section 220.83(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Building Square Footage VA (watts)Amps House 1251 3753 15.64 Amps Box A (VA) 15.64 3753Total for Part #1: Part #2 - Section 220.83(B)(2),(4) a, b, c, d - Appliances and Dedicated Circuits: Dedicated Circuit Size in VA Dedicated Circuit Size in VA Stove 9600 N/A Laundry 1500 N/A Appliance Circuit(s)3000 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Amps Box B (VA) N/A 14100 58.75Total for Part #2: Total VA from Parts #1 and #2 combined:Box A + Box B = 3811.75 Total VA 17853 First 8000 VA @ 100% 8000 Remaining VA @ 40% Remaining VA = 9853 9853 x 40% = 3941.2 VA Adding First 8,000 VA 8000 VA 11941.2 VA 49.76 Amps Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits: Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits: Part #3 - Section 220.83(B) Heating and A/C loads: 100% of all the Heating or A/C loads in VA: 0 VA 100% of all the Heating or A/C loads in Amps: 0 A *Combine the larger loads of either the Heating or the A/C loads togther Totals from all Parts VA Volts Amps Parts #1 & #2 11941.2 240 49.76 Part #3 0 240 0 Total VA for all Parts: 11941.2 Totals Service/Feeder Load 49.76 1312 S Hickory St 5/5/2025 Panel 1 of 1 Bus Rating: 200 Main Rating: 200 Panel % of Sq.Ft: 100%Panel % of 100% VA: 100% Stove 9600 Appliance Circuit 1 1500 laundry 1500 Appliance Circuit 2 1500 Itemized House and 240V Loads for Panel: (VA) Not Fed by other panels Load Calc: (This Panel) 49.76 Total Load Calc: 49.76 1312 S Hickory St 5/5/2025 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST SUNRUN CA CL #750184 1312 S Hickory St Santa Ana CA USA 92707 YES NO Are the following applicable to the proposed project? 1.  Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.  Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.  Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.  Will the PV system weigh maximum 4 pounds per square feet or less? 5.  Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.  Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.  Will the PV system be installed without using any ballast system or counter-weight system? 8.  Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.  Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.  Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: caitlyn hernandez 3854005019 oc_permits@sunrunc.om 4.11.25 1312 S Hickory St 5/5/2025