Loading...
HomeMy WebLinkAbout1145 S Shelton St Unit# 2 - PlanHOUSE: 1,023 SQ. FT. (EXISTING) HOUSE: 800 SQ. FT. (PROPOSED ADU) HOUSE + ADU + GARAGE = 2,222 SQ. FT. BEDROOMS - 2 (EXISTING) BEDROOMS - 3 (PROPOSED ADU ) FIRE SPRINKLERS - NO - EXISTING FIRE SPRINKLERS - YES - PROPOSED ADU TYPE OF CONSTRUCTION (EXISTING) - V-B TYPE OF CONSTRUCTION - (PROPOSED ADU) -V-B(TITLE 25) EXTERIOR WALL - STUCCO - (EXISTING) EXTERIOR WALL - STUCCO - (PROPOSED ADU) ROOFING MATERIAL - COMPOSITION SHINGLE - EXISTING ROOFING MATERIAL - COMPOSITION SHINGLE - PROPOSED ADU LOT SIZE = 6,716 SQ.FT. LOT COVERAGE = 33% PROPERTY ADDRESS: 1145 S SHELTON ST., UNIT 2, SANTA ANA, CA 92707 PROPERTY OWNER: SCOTT, BRYAN B; SCOTT, KATHIE H LEGAL DESCRIPTION: LOT NUMBER: 61 TRACT NO: 557 GENERAL CONTRACTOR: USMODULAR INC. /LICENSE #943047 TODD KESSLER /951 809 2668 00-G-00: COVER PAGE 01-C-200: SITE PLAN 01-A-301: ELEVATIONS PROJECT: SCOTT ACCESSORY DWELLING UNIT APN: 013-061-14 TODDK@USMODULARINC.COM BILL CAVANAUGH /619 507 2727 ZONING: R-1 SINGLE FAMILY BRIEF DESCRIPTION: N TR 557 BLK LOT 61 BILLC@USMODULARINC.COM SOLAR - EXISTING - NO SOLAR - PROPOSED ADU - EXEMPT - TITLE 25 02-S1-1: FOUNDATION PLAN MANUFACTURED HOME REGULATIONS: CALIFORNIA CODE OF REGULATIONS TITLE 25 DIVISION 1, CHAPTER 3, SUBCHAPTER S 24 CFR 3280 & 3282 NOTES: FIRE SPRINKLER WILL BE INSTALLED IN THE ADU/MANUFACTURED HOME = NFPA 13D NO SOLAR REQUIRED - SEE SECTION 8 01-A-201: FLOOR PLANGARAGE: 399 SQ. FT. OPEN SPACE: 1,530 SQ.FT. 01-C-400: TRANSIT MAP 01-A-801: WINDOW AND DOOR SCHEDULE 02-S-3.1: STRUCTURAL ROOF PLAN 02-S-3.2: STRUCTURAL BUILDING SECTION 05-E-302: ELECTRICAL PLAN 07-P-303: PLUMBING PLAN 07-P-303.1: MECHANICAL PLAN 02-S1-1A: FOUNDATION PLAN 02-S1-1B: FOUNDATION PLAN 02-S1-1C: FOUNDATION PLAN CODE YEAR: 2022 CALIFORNIA CODE OF REGULATIONS WUI - YES - PROPOSED ADU 01-A-401: WUI SPECIFICAITONS SCOPE OF WORK: NEW CONSTRUCTION OF STATE OF CA APPROVED MANUFACTURED HOME AS ADU ON A STATE APPROVED PERMANENT FOUNDATION - CONNECTION TO EXISTING UTILITIES ADU SQ.FT. TO EXISTING HOUSE 800/1,023=78.2% NO ADU PARKING REQUIRED AS ADU IS WITHIN 1/2 MILE FROM PUBLIC TRANSIT 8' - 0 " 1ST FLOOR 1ST CEILING 18'-0" FRONT ELEVATION (E) 11 ' - 1 1 1 2" 1145 S SHELTON ST SANTA ANA, CA 92707 APN: 013-061-14 12 NOMINAL 3 12 ' - 9 1 2" 71 " COMP SHINGLE ROOF TO MATCH GARAGE AND EXISTING HOUSE STUCCO TO MATCH MAIN HOUSE COMP SHINGLE ROOF TO MATCH GARAGE AND EXISTING HOUSE HOUSE: 1,023 SQ. FT. (EXISTING) HOUSE: 800 SQ. FT. (PROPOSED ADU) HOUSE + ADU + GARAGE = 2,222 SQ. FT. BEDROOMS - 2 (EXISTING) BEDROOMS - 3 (PROPOSED ADU ) FIRE SPRINKLERS - NO - EXISTING FIRE SPRINKLERS - YES - PROPOSED ADU TYPE OF CONSTRUCTION (EXISTING) - V-B TYPE OF CONSTRUCTION - (PROPOSED ADU) -V-B(TITLE 25) EXTERIOR WALL - STUCCO - (EXISTING) EXTERIOR WALL - STUCCO - (PROPOSED ADU) ROOFING MATERIAL - COMPOSITION SHINGLE - EXISTING ROOFING MATERIAL - COMPOSITION SHINGLE - PROPOSED ADU LOT SIZE = 6,716 SQ.FT. LOT COVERAGE = 33% PROPERTY ADDRESS: 1145 S SHELTON ST., UNIT 2, SANTA ANA, CA 92707 PROPERTY OWNER: SCOTT, BRYAN B; SCOTT, KATHIE H LEGAL DESCRIPTION: LOT NUMBER: 61 TRACT NO: 557 GENERAL CONTRACTOR: USMODULAR INC. /LICENSE #943047 TODD KESSLER /951 809 2668 00-G-00: COVER PAGE 01-C-200: SITE PLAN 01-A-301: ELEVATIONS PROJECT: SCOTT ACCESSORY DWELLING UNIT APN: 013-061-14 TODDK@USMODULARINC.COM BILL CAVANAUGH /619 507 2727 ZONING: R-1 SINGLE FAMILY BRIEF DESCRIPTION: N TR 557 BLK LOT 61 BILLC@USMODULARINC.COM SOLAR - EXISTING - NO SOLAR - PROPOSED ADU - EXEMPT - TITLE 25 02-S1-1: FOUNDATION PLAN MANUFACTURED HOME REGULATIONS: CALIFORNIA CODE OF REGULATIONS TITLE 25 DIVISION 1, CHAPTER 3, SUBCHAPTER S 24 CFR 3280 & 3282 NOTES: FIRE SPRINKLER WILL BE INSTALLED IN THE ADU/MANUFACTURED HOME = NFPA 13D NO SOLAR REQUIRED - SEE SECTION 8 01-A-201: FLOOR PLANGARAGE: 399 SQ. FT. OPEN SPACE: 1,530 SQ.FT. 01-C-400: TRANSIT MAP 01-A-801: WINDOW AND DOOR SCHEDULE 02-S-3.1: STRUCTURAL ROOF PLAN 02-S-3.2: STRUCTURAL BUILDING SECTION 05-E-302: ELECTRICAL PLAN 07-P-303: PLUMBING PLAN 07-P-303.1: MECHANICAL PLAN 02-S1-1A: FOUNDATION PLAN 02-S1-1B: FOUNDATION PLAN 02-S1-1C: FOUNDATION PLAN CODE YEAR: 2022 CALIFORNIA CODE OF REGULATIONS WUI - YES - PROPOSED ADU 01-A-401: WUI SPECIFICAITONS SCOPE OF WORK: NEW CONSTRUCTION OF STATE OF CA APPROVED MANUFACTURED HOME AS ADU ON A STATE APPROVED PERMANENT FOUNDATION - CONNECTION TO EXISTING UTILITIES ADU SQ.FT. TO EXISTING HOUSE 800/1,023=78.2% NO ADU PARKING REQUIRED AS ADU IS WITHIN 1/2 MILE FROM PUBLIC TRANSIT 8' - 0 " 1ST FLOOR 1ST CEILING 18'-0" FRONT ELEVATION (E) 11 ' - 1 1 1 2" 1145 S SHELTON ST SANTA ANA, CA 92707 APN: 013-061-14 12 NOMINAL 3 12 ' - 9 1 2" 71 " COMP SHINGLE ROOF TO MATCH GARAGE AND EXISTING HOUSE STUCCO TO MATCH MAIN HOUSE COMP SHINGLE ROOF TO MATCH GARAGE AND EXISTING HOUSE Bldg #101121577 APPROVALS: PLNG - C. Santana BLDG - J. Lo POLICE - B. Martin PUBLIC WORKS - Y. Soto 1145 S Shelton St Unit# 24/22/2025 VS B 4 2 2-6 WA S H E R DR Y E R 2-8 SH E L F WH 36"x36" LANDING 2- 6 SH4046 BOX FOR FAN/LIGHT W.P. 2- 6 2- 6 SH3046 2- 6 2- 6 SH 3 0 4 6 VS B 4 2 2-6 W.P. 2- 6 W36121" F SB36 DW SH3030 W3030 B9 W3 0 1 2 WC2430 BB C 3 6 / 3 9 3"F W1 8 3 0 DB 1 8 2- 6 BOX FOR FAN/LIGHT FURNACE2- 0 CL G A C C PA N E L 3-0 36"x36" PORCH SH3046-2 9' - 5 " 9' - 5 " 10 ' - 0 " 10 ' - 0 " 20 ' - 0 " 4'-11"2'-6"3'-6"11'-1"4'-11"2'-0"8'-0" 40'-0" 9' - 5 " 9' - 5 " 8'-0"2'-0"15'-10"2'-0"10'-0" 8'-81 2" 3'-2" 1 1 / 2 " F 1145 S Shelton St Unit# 24/22/2025 8' - 0 " 1ST FLOOR 1ST CEILING LEFT ELEVATION (S) 18'-0" RIGHT ELEVATION (N) 12 NOMINAL 3 FRONT ELEVATION (E) REAR ELEVATION (W) 11 ' - 1 1 1 2" 8' - 0 " 1ST FLOOR 1ST CEILING 1145 S SHELTON ST SANTA ANA, CA 92707 APN: 013-061-14 12 NOMINAL 3 12 NOMINAL 3 12 ' - 9 1 2" 11 ' - 1 1 1 2" 12 ' - 9 1 2" 11 ' - 1 1 1 2" 12 ' - 9 1 2" 11 ' - 1 1 1 2" 12 ' - 9 1 2" 71 2" 71 2" 71 2" 71 2" 71 2" 6" 6" NOTE: EXTERIOR FINISHES OF ADU TO BE SUBSTANTIALLY SAME AS EXISTING PRIMARY DWELLING INCLUDING DESIGN, PITCH, COLOR AND TEXTURE & WINDOW TRIM. COMP SHINGLE ROOF TO MATCH GARAGE AND EXISTING HOUSE STUCCO TO MATCH MAIN HOUSE STUCCO TO MATCH MAIN HOUSE STUCCO TO MATCH MAIN HOUSE COMP SHINGLE ROOF TO MATCH GARAGE AND EXISTING HOUSE STUCCO TO MATCH MAIN HOUSE 1145 S Shelton St Unit# 24/22/2025 1'-4" 6' - 0 " 3' - 0 " 11" 11" 1'-0" 1' - 4 " 1' - 4 " 1' - 4 " 1' - 4 " 1' - 4 " 5' - 0 " U . N . O . 5' - 0 " (T - 7 ) 5' - 4 " (T - 6 ) 4' - 6 " (T - 3 ) 2' - 1 0 " (T - 2 ) 2' - 0 " (T - 1 ) 1145 S Shelton St Unit# 24/22/2025 20'-0"4.5' 93' 6' 4' - 0 " 40 ' - 0 " 4'-0" 1145 S Shelton St Unit# 24/22/2025 1145 S Shelton St Unit# 24/22/2025 1 of 3: 02-S1-1 1145 S Shelton St Unit# 24/22/2025 2 of 3: 02-S1-1A 1145 S Shelton St Unit# 24/22/2025 3 of 3: 02-S1-1B 1145 S Shelton St Unit# 24/22/2025 1145 S Shelton St Unit# 24/22/2025 VS B 4 2 2-6 WA S H E R DR Y E R 2-8 SH E L F WH 2- 6 SH4046 BOX FOR FAN/LIGHT W.P. 2- 6 2- 6 SH3046 2- 6 2- 6 SH 3 0 4 6 VS B 4 2 2-6 W.P. 2- 6 W3612 1" F SB36 DW SH3030 W3030 B9 W3 0 1 2 WC2430 BB C 3 6 / 3 9 3"F W1 8 3 0 DB 1 8 2- 6 BOX FOR FAN/LIGHT FURNACE 2- 0 CL G A C C PA N E L 3-0 SH3046-2 9' - 5 " 9' - 5 " 10 ' - 0 " 10 ' - 0 " 20 ' - 0 " 4'-11" 2'-6" 3'-6" 11'-1" 4'-11" 2'-0" 8'-0" 40'-0" 9' - 5 " 9' - 5 " 8'-0"2'-0"15'-10" 2'-0" 10'-0" 8'-81 2" 3'-2" 1 1 / 2 " F #23 Conforms to HUD MHCSS 06/25/23 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 8' - 0 " 1ST FLOOR 1ST CEILING LEFT ELEVATION 18'-0" RIGHT ELEVATION 12 NOMINAL 3 FRONT ELEVATION REAR ELEVATION 11 ' - 1 1 1 2" 8' - 0 " 1ST FLOOR 1ST CEILING 12 NOMINAL 3 12 NOMINAL 3 11 ' - 1 1 1 2" 11 ' - 1 1 1 2" 11 ' - 1 1 1 2" 6" 6" #23 Conforms to HUD MHCSS 06/25/23 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 NO M I N A L 3 : 1 2 NO M I N A L 3 : 1 2 6" 6" COMP SHINGLE COMP SHINGLE #23 Conforms to HUD MHCSS 06/25/23 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 BUILDING SECTION 12 NOMINAL 3 20'-0" 8' - 0 " 10 " 11 ' - 1 1 1 2" 10'-0"10'-0" 2' - 1 1 16 " 6"6" #23 Conforms to HUD MHCSS 06/25/23 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 GFI 100 CFM WH WP GFI GFI GFI BOX FOR FAN/LIGHT W.P. GFI 100 CFM W.P. GFI GFI BOX FOR FAN/LIGHT GFI to a t t i c l i g h t WP GFI ELECTRIC SYMBOLS WP GFI GFI SD/CO AC/DC SD AC/DC 100 CFM GFI SD/CO AC/DC SD AC/DC SD AC/DC SD AC/DC SD/CO AC/DC #23 Conforms to HUD MHCSS 06/25/24 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 #23 Conforms to HUD MHCSS 06/25/23 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 #23 Conforms to HUD MHCSS 06/25/24 Limited Approval 180 Days755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 R MODIFICATIONS PROJECT: DRAWN Y: DATE: SCALE: TITLE: FILENAME: DATE: SCALE: SHEET: PROPRIETARY AND CONFIDENTIAL THESE DRAWINGS AND SPECIFICATIONS ARE ORIGINAL PROPRIETARY AND CONFIDENTIAL MATERIALS OF CHAMPION. COPYRIGHT- +926-2021 BY CHAMPION HOME BUILDERS 755 W. BIG BEAVER ROAD, SUITE 1000 TROY, MI 48084 PHONE: 248-614-8200 1145 S Shelton St Unit# 24/22/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 3 jessielopez@santa-ana.org Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Jessie Lopez COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez David Penaloza Thai Viet Phan Benjamin Vazquez CITY OF SANTA ANA Planning and Building Agency 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Kristine Ridge CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall Also sent via email to: Bryanbscott@gmail.com October 5, 2023 Bryan Scott 1145 S. Shelton Street Santa Ana, CA 92707 Subject: Address Assignment for a new Accessory Dwelling Unit located at 1145 South Shelton Street (APN: 013-061-14) in Santa Ana, CA. Dear Bryan, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit located at 1145 South Shelton Street (APN: 013-061-14). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 1. 1145 South Shelton Street, Unit 2 (Address for New ADU) To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2709 or by email at ASevilla@santa-ana.org]. Sincerely, Alexis Sevilla Planning Technician Reviewed by: Jerry Guevara, Senior Planner Exhibit A – Address Plan 1145 S Shelton St Unit# 24/22/2025 Address Letter for 1145 South Shelton Street Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 1145 S Shelton St Unit# 24/22/2025 20'-0"4.5' 6' 4' - 0 " 40 ' - 0 " 4'-0" (E) 1145 SOUTH SHELTON STREET (N) 1145 SOUTH SHELTON STREET, UNIT 2 EXHIBIT A - ADDRESS PLAN 1145 S Shelton St Unit# 24/22/2025 State of California HEALTH AND SAFETY CODE Section 18551 18551. The department shall establish regulations for manufactured home, mobilehome, and commercial modular foundation systems that shall be applicable throughout the state. When established, these regulations supersede any ordinance enacted by any city, county, or city and county applicable to manufactured home, mobilehome, and commercial modular foundation systems. The department may approve alternate foundation systems to those provided by regulation if the department is satisfied of equivalent performance. The department shall document approval of alternate systems by its stamp of approval on the plans and specifications for the alternate foundation system. A manufactured home, mobilehome, or commercial modular may be installed on a foundation system as either a fixture or improvement to the real property, in accordance with subdivision (a), or a manufactured home or mobilehome may be installed on a foundation system as a chattel, in accordance with subdivision (b). (a)  Notwithstanding any other law, prior to a manufactured home, mobilehome, or commercial modular being deemed a fixture or improvement to the real property, the installation shall comply with all of the following: (1)  Prior to installation of a manufactured home, mobilehome, or commercial modular on a foundation system, the manufactured home, mobilehome, or commercial modular owner or a licensed contractor shall obtain a building permit from the appropriate enforcement agency. To obtain a permit, the owner or contractor shall provide the following: (A)  Written evidence acceptable to the enforcement agency that the manufactured home, mobilehome, or commercial modular owner owns, holds title to, or is purchasing the real property where the mobilehome is to be installed on a foundation system. A lease held by the manufactured home, mobilehome, or commercial modular owner, that is transferable, for the exclusive use of the real property where the manufactured home, mobilehome, or commercial modular is to be installed, shall be deemed to comply with this paragraph if the lease is for a term of 35 years or more, or if less than 35 years, for a term mutually agreed upon by the lessor and lessee, and the term of the lease is not revocable at the discretion of the lessor except for cause, as described in subdivisions 2 to 5, inclusive, of Section 1161 of the Code of Civil Procedure. Notwithstanding Section 18555, a registered owner of a manufactured home or mobilehome in a mobilehome park that is converted or proposed to be converted to a resident-owned subdivision formed pursuant to Section 11010.8 of the Business and Professions Code, stock cooperative, as defined in Section 4190 of the Civil Code, or condominium project, as defined in Section 4125 of the Civil Code, may submit 1145 S Shelton St Unit# 24/22/2025 written evidence of that owner’s resident ownership in the mobilehome park in order to comply with this paragraph. (B)  Written evidence acceptable to the enforcement agency that the registered owner owns the manufactured home, mobilehome, or commercial modular free of any liens or encumbrances or, in the event that the legal owner is not the registered owner, or liens and encumbrances exist on the manufactured home, mobilehome, or commercial modular, written evidence provided by the legal owner and any lienors or encumbrancers that the legal owner, lienor, or encumbrancer consents to the attachment of the manufactured home, mobilehome, or commercial modular upon the discharge of any personal lien, that may be conditioned upon the satisfaction by the registered owner of the obligation secured by the lien. (C)  Plans and specifications required by department regulations or a department-approved alternate for the manufactured home, mobilehome, or commercial modular foundation system. (D)  The manufactured home, mobilehome, or commercial modular manufacturer’s installation instructions, or plans and specifications signed by a California-licensed architect or engineer covering the installation of an individual manufactured home, mobilehome, or commercial modular in the absence of the manufactured home, mobilehome, or commercial modular manufacturer’s instructions. (E)  Building permit fees established by ordinance or regulation of the appropriate enforcement agency. (F)  A fee payable to the department in the amount of eleven dollars ($11) for each transportable section of the manufactured home, mobilehome, or commercial modular, that shall be transmitted to the department at the time the certificate of occupancy is issued with a copy of the building permit and any other information concerning the manufactured home, mobilehome, or commercial modular that the department may prescribe on forms provided by the department. (2)  (A)  Within five business days of the issuance of the certificate of occupancy for the manufactured home, mobilehome, or commercial modular by the appropriate enforcement agency, the enforcement agency shall record a document naming the owner of the real property, describing the real property with certainty, and stating that a manufactured home, mobilehome, or commercial modular has been affixed to that real property by installation on a foundation system pursuant to this subdivision. The document shall be recorded with the county recorder of the county where the real property, upon which the manufactured home, mobilehome, or commercial modular that has been installed, is situated. (B)  When recorded, the document referred to in subparagraph (A) shall be indexed by the county recorder to the named owner and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. (C)  Fees received by the department pursuant to subparagraph (F) of paragraph (1) shall be deposited in the Mobilehome-Manufactured Home Revolving Fund established under subdivision (a) of Section 18016.5. (3)  The certification of title and other indicia of registration shall be surrendered to the department pursuant to regulations adopted by the department providing for 1145 S Shelton St Unit# 24/22/2025 the cancellation of registration of a manufactured home, mobilehome, or commercial modular that is permanently attached to the ground on a foundation system pursuant to this subdivision. For the purposes of this subdivision, permanent affixation to a foundation system shall be deemed to have occurred on the day a certificate of occupancy is issued to the manufactured home, mobilehome, or commercial modular owner and the document referred to in subparagraph (A) of paragraph (2) is recorded. Cancellation shall be effective as of that date and the department shall enter the cancellation on its records upon receipt of a copy of the certificate of occupancy. This subdivision shall not be construed to affect the application of existing laws, or the department’s regulations or procedures with regard to the cancellation of registration, except as to the requirement therefor and the effective date thereof. (4)  Once installed on a foundation system in compliance with this subdivision, a manufactured home, mobilehome, or commercial modular shall be deemed a fixture and a real property improvement to the real property to which it is affixed. Physical removal of the manufactured home, mobilehome, or commercial modular shall thereafter be prohibited without the consent of all persons or entities who, at the time of removal, have title to any estate or interest in the real property to which the manufactured home, mobilehome, or commercial modular is affixed. (5)  For the purposes of this subdivision: (A)  “Physical removal” shall include, without limitation, the unattaching of the manufactured home, mobilehome, or commercial modular from the foundation system, except for temporary purposes of repair or improvement thereto. (B)  Consent to removal shall not be required from the owners of rights-of-way or easements or the owners of subsurface rights or interests in or to minerals, including, but not limited to, oil, gas, or other hydrocarbon substances. (6)  At least 30 days prior to a legal removal of the manufactured home, mobilehome, or commercial modular from the foundation system and transportation away from the real property to which it was formerly affixed, the manufactured home, mobilehome, or commercial modular owner shall notify the department and the county assessor of the intended removal of the manufactured home, mobilehome, or commercial modular. The department shall require written evidence that the necessary consents have been obtained pursuant to this section and shall require application for either a transportation permit or manufactured home, mobilehome, or commercial modular registration, as the department may decide is appropriate to the circumstances. Immediately upon removal, as defined in this section, the manufactured home, mobilehome, or commercial modular shall be deemed to have become personal property and subject to all laws governing the same as applicable to a manufactured home, mobilehome, or commercial modular. (b)  The installation of a manufactured home or a mobilehome on a foundation system as chattel shall be in accordance with Section 18613 and shall be deemed to meet or exceed the requirements of Section 18613.4. This subdivision shall not be construed to affect the application of sales and use or property taxes. No provisions of this subdivision are intended, nor shall they be construed, to affect the ownership interest of any owner of a manufactured home or mobilehome. 1145 S Shelton St Unit# 24/22/2025 (c)  Once installed on a foundation system, a manufactured home, mobilehome, or commercial modular shall be subject to state-enforced health and safety standards for manufactured homes, mobilehomes, or commercial modulars enforced pursuant to Section 18020. (d)  No local agency shall require that any manufactured home, mobilehome, or commercial modular currently on private property be placed on a foundation system. (e)  No local agency shall require that any manufactured home or mobilehome located in a mobilehome park be placed on a foundation system. (f)  No local agency shall require, as a condition for the approval of the conversion of a rental mobilehome park to a resident-owned park, including, but not limited to, a subdivision, stock cooperative, or condominium project for mobilehomes, that any manufactured home or mobilehome located there be placed on a foundation system. This subdivision shall only apply to the conversion of a rental mobilehome park that has been operated as a rental mobilehome park for a minimum period of five years. (Amended by Stats. 2018, Ch. 254, Sec. 1. (AB 1943) Effective September 5, 2018.) 1145 S Shelton St Unit# 24/22/2025 From: Westfall, John@HCD [mailto:John.Westfall@hcd.ca.gov] Sent: Thursday, June 4, 2020 9:32 AM To: Bill Cavanaugh; Todd Kessler Cc: Humphreys, Daniel@HCD Subject: MH Installation (MHI) Submittal Requirements Todd & Bill: Here’s what the local enforcing agency can ask for. We understand sometimes projects are behind and homeowner willing to do anything for kickstarting the permit: only encourages them for next MHI. I appreciate you sharing this information with them. Some installers regularly include this information with their submittals. The greater regulatory(HSC Div 12 Part 2 Chapter 5 Article 1 -18551) section(s) can be found at this link. This email and information are responsive to your original request for information. If you have any further questions, please ask. John J. Westfall District Representative II Manufactured and Factory-Built Housing Programs CA Department of Housing & Community Development 9342 Tech Center Drive, Suite 500 | Sacramento, CA 95826-2581 Phone: 916.263.7430 | Fax: 916.263.4713 john.westfall@hcd.ca.gov This email and any files attached are intended solely for the use of the individual or entity to which they are addressed. If you have received this email in error, please notify the sender immediately. This email and the attachments have been electronical ly scanned for email content security threats, including but not limited to viruses. 1145 S Shelton St Unit# 24/22/2025 Build Home Assign HUD Labels Manufacturer Certificate of Origin (MCO) DISTRIBUTION OF MCO Pink Copy (Original )= Inventory Creditor. If none, to Dealer. White copy = HCD Yellow copy = Transporter Goldenrod = Manufacturer Manufacturer’s Responsibilities Transporter’s Responsibilities Deliver home to Dealer’s lot Or Other specified location agreed to in the escrow instructions Dealer’s Responsibilities (Home not subject to Registration with HCD no titling documents issued) Sell home or Take order for home Obtain building permit to install home from enforcement agency. OR Owner responsibility Install home OR Owner responsibility Have home inspected by enforcement agency OR Owner responsibility Complete Dealer’s Report of Sale (DRS) and submit to HCD with all required documents and fees within 10 days of date of sale Date of Sale is the date escrow closes or the home is delivered. Provide ongoing warranty services as required Local Enforcement Agency Responsibilities Issue building permit to install home to dealer/ installer/owner Collect documents from the owner prior to issuing permit. Written Evidence: The registered owner owns, is purchasing, or has a transferable lease for the real property where the home is to be installed; The registered owner owns the home free of any liens or encumbrances or that any lien holders agree to the attachment of the home on the real property. (As evidenced by the submittal of the MCO to the enforcement agency for new homes or for used home that any title or registration card for the home be surrendered to the enforcement agency. Plans and specifications required by HCD regulations or an approved alternate for the homes foundation system. The manufacturer’s installation instructions, or plans and specifications signed by a California licensed architect or engineer covering the installation of the home when the manufacturer’s installation instructions cannot be provided Applicable permit fees. An $11 per section fee payable to HCD. Conduct the inspection and reinspection(s), if necessary MANUFACTURED HOMES INSTALLED ON A FOUNDATION SYSTEM AS AN IMPROVEMENT TO REAL PROPERTY (HEALTH AND SAFETY CODE SECTION 18551(a)) FLOWCHART Complete conditional sales contract or purchase order Obtain deposit/down payment Open escrow pursuant to HSC §18035.2 or §18035.26 Issue Certificate of Occupancy and record form HCD 433A with the county recorder where the home is located Forward copy of the recorded HCD 433A, the $11 per section fee, and the titling document to HCD Registration & Titling Page 1 of 2 (Revised 2/14) Owner installed units need to submit DRS prior to the home’s installation. 1145 S Shelton St Unit# 24/22/2025 County Recorder’s Responsibilities Index the HCD 433A to the named homeowner HCD’s Responsibilities Review and process application submitted by dealer to report the sale of the manufactured home onto the 18551(a) foundation system. HCD’s permanent title record is cancelled and the record status is changed to “Permanent Foundation 18551.” Fees are no longer collected by the department. Complete Dealer’s Report of Sale and submit to HCD with all required documents and fees within 10 days of the date of sale Submit Issue Certificate of Occupancy and record form HCD 433A with the county recorder where the manufactured home is located on within 5 days Forward copy of the recorded HCD 433A, the $11 per section fee, and the titling document to HCD Review Local Enforcement Agency’s Responsibilities Dealer’s Responsibilities 2Page 2 of 2 Open escrow (Revised 2/14) MANUFACTURED HOMES INSTALLED ON A FOUNDATION SYSTEM AS AN IMPROVEMENT TO REAL PROPERTY (HEALTH AND SAFETY CODE SECTION 18551(a)) FLOWCHART 1145 S Shelton St Unit# 24/22/2025 1145 S Shelton St Unit# 24/22/2025 1145 S Shelton St Unit# 24/22/2025 To: City of Santa Ana Building Department Plans Examiner Subject: Bryan Scott ADU 1145 S Shelton Street, #2 Santa Ana, CA 92707 APN: 013-061-14 References: State approved general foundation plan for this project, dated 01/10/2024 Orange Empire Foundation Requirements for Residential Projects and Accessory Structures, Rev: 7/1/2024 Architectural plan set for this project by US Modular, Inc., Rev: 11/22/2023 To whom it may concern, 1. Since the footings are already designed to bear at 28" min. below finish grade, the 24" minimum depth is met, embedded a minimum of 12" below the crawl space grade. I recommend installing (2) continuous #5 rebars in the footing and (2) continuous #5 rebars in the top course of the stem wall to meet the (2) #5 bars top and bottom, effectively creating 36" deep grade beams all around. To add shear resistance and possible out of plane soil pressure resistance, I recommend doubling the vertical bars by decreasing the spacing from 48" o.c. to 24" o.c. The stem wall shall be 8" thick with solid grout. The footing shall be of 4,500 psi, type 5 cement, with a maximum water : cement ratio of 0.45. The exterior side of the stem wall shall dampproofed and protected with an additional 10 mil. poly vapor barrier. 2. The interior pad footings shall be 18" thick, embedded 18" below the crawl space grade, sized to meet the required bearing area per the manufacturer's installation manual. Pad footings not more than 24" square will not experience bending forces. Therefore reinforcement is not required. Pad footing greater than 24" square shall have #4 bars at 8" max. o.c. each way, at 3" from the bottom. (951) 972-0769 Principal Engineer I have reviewed the referenced documents for this project. The referenced 800 sf manufactured ADU meets the exception requirement no. 2 . Therefore I recommend construction per the installation manual and the referenced general foundation plan set with the following comments and modifications to comply with the referenced foundation construction requirements: If you have any questions or concerns, please contact me at the number listed below. Sincerely, Neal G. Wanket, P.E. (CA RCE 68856) October 21, 2024 1145 S Shelton St Unit# 24/22/2025