Cover Sheet
A0
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
-
---
Vicinity Map
Scope of Work
Project Info Applicable Codes
Building Summary Consultants
SHEET INDEX
Sheet Sheet Name
A0 Cover Sheet
A0.1 Site Plans
A1 Floor Plans + Schedules
A2 Elevations + Sections
A3 Roof + Electrical Plan
A4 Main Home Elevations
GN General Notes
GRN1 Green Notes
S1 General Notes + Details
S2 Deputy Inspection + Structural
Observation Notes
S3 General Details
S4 Wood Shear Wall Framing + Notes
S5 Foundation + Roof Framing Plan
S6 Section + Details
S7 Section + Details
T24 Title 24 Energy Analysis
T24.2 Title 24 Energy Analysis
Convert Existing Garage (397 SF)
to ADU with 150 SF Addition
&
Removal of Existing unpermitted
A/C
Construction Type:
Occupancy Group:
Fire Sprinklers:
Legal Description-
Tract #:
Lot #:
Block #:
APN #:
Zoning:
# of Stories:
Lot Size:
VB
R3
Not Required
TR 1057
5
###
405-292-05
R1-1
1
8,160 SQ. FT.
ADU : SFD =
Existing Dwelling:
Existing Garage
ADU conversion:
ADU Addition:
Lot Area:
Existing Lot Coverage:
Proposed Lot Coverage:
547 SF: 1910 SF.
= 28.6% Ratio
1,910 SQ. FT.
397 SQ. FT.
150 SQ. FT.
8,160 SQ. FT.
28%
30 %
Structural Eng.
Keshishian Engineering
2654 Risa Dr
Glendale, CA 91208
818 939 7870
Title 24
Promech Eng. INC
325 Parkwood Dr.
Glendale CA 91202
Tel. (818) 281 7654
- 2022 CA BUILDING CODE
- 2022 CA RESIDENTIAL CODE
- 2022 CA ENERGY CODE
- 2022 CA GREEN BUILDING STANDARDS
- 2022 CA HISTORICAL BUILDING CODE
- 2022 CA EXISTING BUILDING CODE
- 2022 CA PLUMBING CODE
- 2022 CA ELECTRICAL CODE
- 2022 CA FIRE CODE
- 2022 CA MECHANICAL CODE
- City of Santa Ana Municipal Code Requirements
At time of permit issuance, contractor shall show their valid
workers' compensation insurance certificate. All work shall
conform to all requirements of State of California Title 24
regardless of the information indicated on these plans. It is
the responsibility of the individual supervising the
construction to ensure that the work is done in accordance
with Code requirements prior to requesting inspection.
Excess or waste concrete may not be washed into the
public way or any other drainage system. Provisions shall
be made to retain concrete wastes on site until they can be
disposed of as solid waste. Sediments and other materials
may not be tracked from the site by vehicle traffic. The
construction entrance roadways may be stabilized so as to
inhibit sediments from being disposited into public way.
Accidental depositions be swept up immediately and may
not be washed down by rain or other means. Stockpiles of
earth and other construction related materials must be
protected from being transported from the site by the
forces of wind or water. Trash and construction related
solid wastes must be deposited into a covered receptacle
to prevent contamination of rainwater and dispersal by
wind. Fuels, oils, solvents and other toxic materials must
be stored in accordance with their listing and are not to
contaminate the soil and surface waters. All approved
storage containers are to be protected from the weather.
Spills must be cleaned up immediately and disposed of in a
properly manner. Spills may not be washed into the
drainage system. South Coast Air Quality Management
District (SCAQMD) shall not be notified in accordance with
California State Law prior to start of any demolition,
addition, and/or remodel work. The South Coast Air Quality
Management District Office is located at 21865 Copley
Drive, Diamond Bar Phone No (909)396-2000. Be sdvised,
SCAQMD may require a 10 day wait period prior to start of
work. All non compliant plumbing fixtures shall be replaced
with water-conserving plumbing fixture prior to final
inspection. Due to the possible presence of lead-based
paint,lead-safe work practices are required for all repairs
and that disturb paint in pre-1979 buildings. Failure to do
so could create could create lead hazards that violate
California Health and Safety Code,
Sections 17920.10 and 105256 with potential fines for
violations up to $5,000 (Section (d) amend) or
imprisonment for not more than 6 months in the county jail
or both.
COMMON AREA CALC:
Common SF:
Bedroom SF:
COMMON >= BEDROOMS
388 SF
120 SF
388 > 120
SITE
Owner
Debbini, Lubna
1108 N Towner Street
Santa Ana, CA 92703
+1 (213) 477-5807
SIDE YARD
All concealed work installed without permits must
be exposed for inspection to the satisfaction of
the Building Inspector. This includes methods of
attachment and all footings, structural members,
mechanical, electrical, plumbing and insulation.
Bldg #101120573
APPROVALS:
PLNG - C. Santana
BLDG - J. Lo
POLICE - B. Martin
PUBLIC WORKS - B. Sarlak
1108 N Towner St &
#212/13/2024
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
AVD24D019
Debbini, Lubna
General Notes
GN
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
Checker
---
1. The construction shall not restrict a five-foot clear and unobstructed access to
any water or power distribution facility (Power poles, pull-boxes, transformers,
vaults, pumps, valves, meters, appurtenances, etc.) or to the location of the
hook-up. The construction shall not be within ten feet of any power lines -
whether or not the lines are located on the property. Failure to comply may
cause construction delays and/or additional expenses.” Obtain approval from
Real Estate Business Unit of DWP (213) 367-0562.
2. Obtain permits from Public Works prior to Construction for:
a. Temporary pedestrian protection as required by LABC Section 3306.
b. For any construction near any street or public area.
3. Outlets along wall counter space, island and peninsula counter space in
kitchens shall have a maximum spacing of 48". (210-52 NEC)
4. The first light in the new and remodeled bathrooms and kitchen shall be an
energy efficient light meeting a minimum of 40 Lumens per watt (e.g. fluorescent
lamp).(T-24, Sec. 130(b) & 150(k))
5. Every space intended for human occupancy shall be provided with natural
light by means of exterior glazed openings in accordance with Section R303.1 or
shall be provided with artificial light that is adequate to provide an average
illumination of 6 foot-candles over the area of the room at a height of 30 inches
above the floor level. (R303.1)
6. A copy of the evaluation report and/or conditions of listing shall be made
available at the job site
7. The sprinkler system shall be approved by Plumbing Division prior to
installation.
8. Plumbing fixtures are required to be connected to a sanitary sewer or to an
approved sewage disposal system (R306.3)
9. Kitchen sinks, lavatories, bathtubs, showers, bidets, laundry tubs and washing
machine outlets shall be provided with hot and cold water and connected to an
approved water supply (R306.4)
10. Automatic garage door openers, if provided, shall be listed in accordance
with UL 325. (R309.4)
11. Los Angeles City Electrical Test Lab Research Report is required to use an
electro-mechanical lift for provided parking spaces.
12. “A maintenance of vehicle lift system (2-levels or more) affidavit ” shall be
approved andrecorded prior to issuing a building permit.
13. A minimum of 65 percent of the nonhazardous construction and demolition
waste shallbe recycle and/or salvage for reuse in accordance with California
Green Building Standards Code, Chapter 4 Division 4.4. (R324)
14. Finish materials including adhesives, sealants, caulks, paints and coating,
aerosol paints and systems and composite wood products shall meet the volatile
organic compound (VOC) emission limits in accordance with the California
Green Building Standards Code, Chapter 4 Division 4.5. (R330)
15. When a vapor retarder is required, a capillary break shall be installed in
accordance with the California Green Building Standards Code, Chapter 4,
Division 4.5. (R506.2.3.1)
16. Annular space around pipes, electric cables, conduits or other openings in
bottom/sole plates at exterior walls shall be protected against the passage of
rodents by closing such openings in accordance with the California Green
Building Standards Code, Chapter 4, Division 4.4. (R602.3.4.1)
A. BATHROOMS
1. All shower enclosures, regardless of shape, shall have a minimum finished
interior area of not less than 1024 square inches (0.66 m2) and shall be capable
of encompassing a 30 inch diameter (0.76 m) circle. The minimum area and
dimensions shall be maintained to a point 70 inches (1.8 m) above the shower
drain outlet. (Plumbing Code Section 410.4)
2. Bathtub and shower floors, walls above bathtubs with a showerhead, and
shower compartments shall be finished with a nonabsorbent surface. Such wall
surfaces shall extend to a height of not less than 6 feet above the floor (R307.2).
3. Provide ultra low flush water closets for all new construction. Existing shower
heads and toilets must be adapted for low water consumption.
4. A min 12" sq. access panel to the bathtub trap slip joint connection is
required. (Plumbing Code Section 405.2)
5. Provide 15" minimum between the center of water closet to any side wall.
(Calif. Plumb. Code 407.6)
6. Provide 24" clear spacce infront of any water closet . (Calif. Plumb. Code
407.6)
B. LAUNDRY ROOM
1. Clothes dryer(s) located in an area that is habitable or containing fuel burning
appliances shall be exhausted to the outside or to an area which is not habitable
and does not contain other fuel burning appliances (but not beneath the building
or in the attic area). (M.C. 504.3.1)
2. A 4" clothes dryer moisture exhaust duct is limited to a 14 feet length with two
elbows from the clothes dryer to the point of termination. Reduce this length by 2
feet for every elbow in excess of 2. (M.C. 504.3.2, M.C. 908)
C. MEANS OF EGRESS
1. Provide 32" wide doors to all interior accessible rooms within a dwelling unit.
(LARC Section R311.2, LABC Section 6304.1)
2. Provide emergency egress from sleeping rooms. Min.- 24" clear ht, 20" clear
width, 5.7 sq.ft. min. area. (LARC Section R310, LABC Section 1029)
3. Occupied roofs shall be provided with exits as required for stories.
4. Provide minimum 9 sf window wells (with fixed ladder) at escape and rescue
opening windows below grade. (R310.2.3)
14. 50 percent of nonhazardous construction and demolition waste shall be recycled and/or
salvaged for reuse in accordance with the California Green Building Code, Chapter 4,
Division 4.4. (R324)
H. STRUCTURAL REQUIREMENTS
1. Provide lead hole 40%-70% of threaded shank dia. and full dia. for smooth shank
portion of Lag Bolts.
2. All bolt holes, other than Lag Bolt holes, shall be drilled 1/32 to 1/16" oversized.
3. Provide lateral support for the top of interior non-bearing walls when manufactured
trusses are used. (LABC 1607.13)
4. Provide double joists under parallel bearing partitions. (LARC Sec. R502.4, LABC
Section 2308.8.4)
5. Provide full length studs (balloon frame) on exterior walls of rooms with vaulted ceiling.
(LARC Section R602.3, LABC Section 2308.9,Table 2308.9.1).
6. All roof and shear wall nailing shall utilize common nails or galvanized box. Nail guns
using “Clipped head” or Sinker nails are not acceptable. (LARC Table R602.3(1), LABC
Table 2304.9.1)
7. Roof nailing to be inspected before covering. Face grain of plywood shall be
Perpendicular to supports. Floor shall have tongue and groove or blocked panel edges.
Plywood spans shall conform with Table 2304.7(3). (LABC Section 2304.7)
8. All horizontal joints occurring in braced wall panels shall occur over blocking equal in
size to the studding. (LARC Section R602.10.8, LABC Section 2308.9.3)
9. Stucco shear walls shall utilize furring, galvanized nails (having a minimum 11 ga.,
1-1/2" long, 7/16" diameter head, and furred out a min of 1/4") to attach the lath to the
studs. Staples shall not be used.” (Table 2507.2). Self furring lath approved by a Los
Angeles Research Report is permitted.
10. Structural wood shear walls shall be covered with minimum two layers 15#
felt underlay prior to placing finish material.
11. Shop welds must be performed in a LA City Bldg. Dept. licensed fabricator ’s shop.
12. Plate washers are required for all hold downs. (LABC Table 2306.4.1)
13. Foundation sills shall be Douglas-Fir (Group II Lumber ) pressure treated or foundation
grade Redwood.(LABC Section .2304.11.2.4).
14. Hold-down connector bolts into wood framing require approved plate washers; and
hold-downs shall be tightened just prior to covering the wall framing.
15. All bolt holes shall be drilled a maximum of 1/16" oversized AND inspector shall verify at
job site.
16. Cutting, Notching, and Boring of Wood Framing Members . (LARC R602.6, LABC Sec.
2089.10, 11)(see diagrams below).
Bored Holes D/3
2 x 6 = 1 13/16"
2 x 8 = 2 7/16"
2 x 10 = 3 1/16"
2 x 12 = 3 3/4"
GENERAL NOTES
D. GRADING AND FOUNDATION
1. If adverse soil conditions are encountered, a soils investigation report may be required.
(LARC Section R401.4)
2. Foundation and floor slabs shall conform to the following or the recommendation of an
approved soils report :
a. Depth of footings below the natural and finished grades shall not be less than 24
inches for exterior and 18 inches for interior footings.
b. Exterior walls and interior bearing walls shall be supported on continuous
footings.
c. Footings shall be reinforced with a minimum 4 - ½ -inch diameter deformed
reinforcing bars. Two bars shall be placed within 4 inches of the bottom of the
footing and two bars within 4 inches of the top of the footings.
d. The soil below an interior concrete slab shall be saturated with moisture to a
depth of 18 inches prior to placing the concrete.
e. Concrete floor slabs on grade shall be placed on a 4" fill of coarse aggregate or
on a moisture barrier membrane. The slabs shall be at least 3½ inch thick and shall be
reinforced with #4 rebars at 16 inch on center in both directions.
3. Concrete slabs on expansive soil, compacted fill or slopes over 1:10 shall be placed on
a 4-inch fill of coarse aggregate or on a 2" sand bed covered moisture barrier
membrane. The slabs shall be at least 3-1/2 inches thick and reinforced with #4 bars
spaced at intervals not exceeding 16 inches on center each way.
(LABC Section 1808.6 , LARC Section R403.1.8, R506.1)
4. Provide Under-floor net ventilation opening size and locations equal to 1 sq. ft. for each
150 sq. ft. of under floor area and an access opening through the floor (18 ” x 24” min) or
an opening through a perimeter wall not less than (16 ” x 24” min). (LARC R408, LABC
Section 2304.11.9, 1203.3)
5. Openings shall be as close to corners as practicable and shall provide cross ventilation
along the length of at least two opposite sides. Opening shall have 1/4 inch corrosion
resistant metal mesh covering. (LABC Section 1203.3, LARC R408.2)
6. Provide corrosion resistant weep screed below the stucco a minimum of 4" above earth
or 2" above paved area. (LARC Section R703.6.2.1, LABC Section 2512.1.2)
7. Provide rain gutters and convey rain water to the street. (LARC R903.4, LABC 1503.4.1,
7013.9)
E. ZONING NOTES
1. A/C units and water heaters are not allowed in the required side yards and front yard
unless specifically allowed by exception per Information bulletin P/ZC 2002-006.
G. SPECIAL HAZARDS
1. Glazing in hazardous locations shall be tempered. (LARC R308, LABC Section 2406.4)
Fixed or operable panels in swinging, sliding and bifold doors and fixed or operable panels
adjacent to doors; Fixed or operable window panels with panes larger than 9 square feet
and are less than 18 inches above the floor, have a top edge greater than 36 inches above
the floor and have one or more walking surfaces within 36 inches, measured horizontally
and in a straight line, of the glazing. Glazing in guards and railings, adjacent to wet
surfaces, adjacent to stairs and ramps, and adjacent to bottom stair landings.
2. Each light of safety glazing material installed in hazardous locations shall be identified
by a permanent label that specifies the labeler, and states that safety glazing material
has been utilized in such installations.
3. Unit Skylights shall be labeled by a LA City Approved Labeling Agency. Such label
shall state the approved labeling agency name, product designation and performance
grade rating (research report not required). (R308.6.9)
4. Pre-fab fireplaces are required to have manufacturer, model, and Underwriter
Laboratories certification (or ICC).
5. Provide an approved spark arrester for the chimney of a fireplace, stove, or barbecue
which uses fuel burning material.” (L.A.M.C. 57.20.25 )
6. An approved Seismic gas shutoff valve will be installed on the fuel gas line on the down
stream side of the utility meter and be rigidly connected to the exterior of the building or
structure containing the fuel gas piping.”(Per Ordinance 171,874-for work over $10,000.)
7. Water heater must be strapped to wall. Section 508.2, LAPC. See Information Bulletin
P/PC 2011-003 “How to Brace Your Water Heater ” for details.
8. For existing pool on site, provide an alarm for doors to the dwelling that form a part of
the pool enclosure. The alarm shall sound continuously for a min. of 30 seconds when
the door is opened. It shall automatically reset and be equipped with a manual means to
deactivate (for 15 seconds. Max.) for a single opening. The deactivation switch shall be
at least 54" above the floor. (6109 of LABC)
9. For existing pool on site, provide anti –entrapment cover meeting the current ASTM or
ASME for the suction outlets of the swimming pool, toddler pool and spa for single
family dwellings per Assembly Bill (AB)No. 2977. (3162B)
10. Smoke detectors shall be provided for all dwelling units intended for human occupancy,
upon the owner’s application for a permit for alterations, repairs, or additions, exceeding
one thousand dollars ($1,000). (R314.6.2)
11. An approved smoke alarm shall be installed in each sleeping room & hallway or area
giving access to a sleeping room, and on each story and basement for dwellings with
more than one story. Smoke alarms shall be interconnected so that actuation of one
alarm will activate all the alarms within the individual dwelling unit. In new construction
smoke alarms shall receive their primary power source from the building wiring and
shall be equipped with battery back up and low battery signal. (R314)
12. An approved carbon monoxide alarm shall be installed in dwelling units
and in sleeping units within which fuel-burning appliances are installed and in dwelling units
that have attached garages. Carbon monoxide alarm shall be provided outside of each
separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s) and on
every level of a dwelling unit including basements. (R315)
13. Where a permit is required for alterations, repairs or additions exceeding one thousand
dollars ($1,000), existing dwellings or sleeping units that have attached garages or
fuel-burning appliances shall be provided with a carbon monoxide alarm in accordance
with Section R315.1. Carbon monoxide alarms shall only be required in the specific
dwelling unit or sleeping unit for which the permit was obtained. (R315.2.2)
14. 50 percent of nonhazardous construction and demolition waste shall be recycled and/or
salvaged for reuse in accordance with the California Green Building Code, Chapter 4,
Division 4.4. (R324)
FLOOR PLAN NOTES:
1. ALL EXTERIOR DOORS SHALL BE WEATHER STRIPPED.
1.1 THE LAND AT REQUIRED OUT-SWINGING DOOR SHALL NOT BE MORE THAN 1 1/2" LOWER THAN THE TOP.
1.2 THE LANDING AT IN-SWINGING DOORS AND DOORS OTHER THAN THE REQUIRED EGRESS SHALL NOT BE
THAN 7 3/4" BELOW THE TOP OF THE THRESHOLD.
2. WALL INSULATION SHALL BE R-15
3. ROOF INSULATION SHALL BE R-38
4. UNDER FLOOR INSULATION SHALL BE R-19
5.. ALL RECEPTACLES IN KITCHEN, BATH AND GARAGE SHALL BE GF1. OUTSIDE RECEPTACLES SHALL BE
WEATHERPROOF.
6. LAMPS USED IN LUMINAIRES FOR GENERAL LIGHTING IN KITCHEN AND BATHROOM SHALL HAVE EFFICIENCY OF NOT
LESS THAN 40 LUMENS PER WATT.
7. ALL WINDOWS SHOULD BE DUAL PANEL
8. ALL BEDROOMS AND HALL AREAS THAT ACCESS BEDROOMS SHALL HAVE SMOKE DETECTORS, HARD WIRE WITH
BATTERY.
9. PROVIDE 30”X22” ATTIC ACCESS SWITCH & LIGHT & RECP.
10. FANS SHALL HAVE 5 AIR CHANGES PER HOUR.
11. WALL COVERING SHALL BE CEMENT PLASTER. TITLE OR APPROVED EQUAL TO 72 ” INCHES ABOVE DRAIN AT
SHOWERS OR TUBS WITH SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS SHALL BE MOISTURE
RESISTANT. GLASS ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY ll. SWING DOOR OUTWARD. NET
AREA OF SHOWER RECEPTOR SHALL NOT BE LESS THAN 1.024 SQ IN OF FLOOR.
12. GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE OF SAFETY GLAZING MATERIAL IN ACCORDANCE WITH
SECTION 2406.4 (SEE EXCEPTIONS):
A) WHERE THE BOTTOM EXPOSED EDGE OF THE WINDOW GLAZING IS LESS THAN 60 INCHES ABOVE A STANDING
SURFACE AND DRAIN INLET OF TUBS AND SHOWERS. @ POWDER ROOM OFF OF KITCHEN.
13. SMOKE DETECTORS ARE REQUIRED IN EACH SLEEPING ROOM, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS, ON EACH STORY, BASEMENT AND HABITABLE ATTICS.
13.1. SMOKE ALARMS SHALL COMPLY WITH SPECIFIC LOCATION REQUIREMENTS PER NFPA 72 SECTION 29.8.3.4 [CRC
R314.3.3]
13.2. SMOKE ALARMS SHALL BE INSTALLED FOR NEW CONSTRUCTION AND ALTERATION [CRC R314.2.1, R314.2.2]
13.3. BATTERY OPERATED SMOKE ALARMS PERMITTED IN EXISTING BUILDINGS WHERE NO CONSTRUCTION IS TAKING
PLACE OR IN BUILDING UNDERGOING ALTERATION OR REPARATION THAT DO NOT RESULT IN THE REMOVAL OF
INTERIOR WALLS, OR CEILING FINISHES, UNLESS THERE IS AN ATTIC, CRAWL SPACE OR BASEMENT. [CRC R314.6,
EXCEPTIONS 1,3]
13.4. SMOKE ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARMS IN THE INDIVIDUAL
DWELLING UNIT [CRC R314.4]
13.5. SMOKE DETECTORS SHALL BE “HARD WIRED ” AND SHALL BE EQUIPPED WITH BATTERY BACKUP. [CRC R314.6]
14. CARBON MONOXIDE ALARM [CRC R315.3]:
SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS
AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENT
14.1. CARBON MONOXIDE ALARM SHALL BE INSTALLED FOR NEW CONSTRUCTION AND ALTERATION [CRC R314.2.1,
R314.2.2]
14.2. CO ALARMS SHALL BE “HARD WIRED ” AND SHALL BE EQUIPPED WITH BATTERY BACK UP.
14.3. CO ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARMS IN THE INDIVIDUAL
DWELLING UNIT [CRC R314.4]
14.4 CO ALARMS SHALL BE INSTALLED FOR COMPLIANCE WITH UL 2034, UL 217, UL 2075 AND MAINTAINED PER NFPA 720
[CRC R315.1.1, CRC R315.6.1, CRC 315.6.2]
14.5 CO ALARMS SHALL BE INSTALLED FOR COMPLIANCE WITH UL 2034, UL 217, UL 2075 AND MAINTAINED PER NFPA 720
[CRC 315.1.1, CRC 315.6.1, CRC 315.6.2]
15. THE ELEVATION OF LANDING SHALL NOT EXCEED 7 1/2 INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY
(IF DOOR DOES NOT SWING OVER THE LANDING). BACK UP.
16. ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (11 LUX).
17. FOR CLOTHES DRYER:
16.1 A MINIMUM 4” MOISTURE EXHAUST DUCT MUST BE PROVIDED
CMC 504.4.2.1
16.2 DRYER EXHAUST CANNOT EXCEED 14 FT. WITH A MAX OF TWO 90 DEG. ELBOWS
CMC 504.4.2.2
16.3. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT. AND CANNOT BE CONCEALED
CMC 504.4.2.2
18. A MINIMUM OF 1” OF SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF
SHEATHING AND AT THE LOCATION OF VENTS FOR VAULTED CEILING OR FLAT ROOFS [CRC R806.3]
OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH
1/16 INCH MIN. AND 1/4 INCH IN MAX. OPENING
A MINIMUM OF 1-INCH AIRSPACE SHALL BE PROVIDED BETWEEN INSULATION AND ROOF SHEATHING
UNVENTED ATTIC ASSEMBLIES SHALL MEET ALL THE CONDITIONS IN SECTION R806.4
1108 N Towner St &
#212/13/2024
A/C to be
removed
Electric Meter
(E
)
D
r
i
v
e
w
a
y
(E) Landscape
(E) Landscape
(E) Pool
(E) Garage
(E) 1,900 SF HOUSE -
NOT SPRINKLERED
60' - 0"
13
7
'
-
0
"
7' - 6"
9' - 1"
12' - 1"12' - 0"19' - 4"
7'
-
1
1
3
/
4
"
11' - 8"
26
'
-
9
"
22
'
-
3
3
/
4
"
24' - 3"7' - 6"28' - 3"
28
'
-
9
"
52
'
-
4
"
14' - 1 1/4"
29
'
-
6
1
/
2
"
(E) SOLAR
(E
)
S
O
L
A
R
Water Meter
Gas Meter
2%2%
2%
2%
2%
5%
(E) Hardscape
ShrubsGrass Dirt
(E) 6ft
Wooden
Fence
(E) 6ft
Wooden
Fence
Gate
Gate
5'
-
0
"
5' Easement
Gate
(E
)
D
r
i
v
e
w
a
y
(E) Landscape To Remain
(E) Hardscape
(E) 1,910 SF HOUSE -
NOT SPRINKLERED
(E) Garage - ADU
Conversion W/
Addition
547 SF
60' - 0"
13
7
'
-
0
"
(E) Patio
2%2%
2%
2%
2%
5%
5%
9' - 1"
Gate
7' - 6"
9' - 1"
12' - 4"11' - 9 1/4"19' - 3 3/4"
26
'
-
3
"
22
'
-
3
3
/
4
"
24' - 3"7' - 6"28' - 3"
28
'
-
9
"
52
'
-
4
"
Water Meter
Gas Meter
0'
-
3
"
(E) SOLAR
(E
)
S
O
L
A
R
ShrubsGrass Dirt
19
'
-
8
1
/
4
"
Landing
(E) Landscape
(E) Pool
11' - 8"14' - 1 1/4"
5%
23' - 6"11
'
-
4
"
23
'
-
0
"
Landing
Minisplit
Condenser
(E) 6ft
Wooden
Fence
(E) 6ft
Wooden
Fence
5'
-
0
"
7"
5' Easement
Remove
Existing
Eave
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
1/8" = 1'-0"
AVD24D019
Debbini, Lubna
Site Plans
A0.1
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
-
---
1/8" = 1'-0"1 Existing Site Plan
1/8" = 1'-0"2 Proposed Site PlanN N
1108 N Towner St & 1108 N Towner St #2
A separate permit is
required for PV system.
The property owner shall
be responsible for confirming all
existing utility easements and /or
clearance on-site that may affect
the project.
1108 N Towner St & 1108 N Towner St #2
1108 N Towner St &
#212/13/2024
Wa
s
h
e
r
Dr
y
e
r
REF.
DW
280 CFM Vent
Hood
Wa
s
h
e
r
Dr
y
e
r
Min. 50 CFM W/Humidity sensor
exhaust fan W/Min. 5 air changes
per hour.
Fans shall be Energy Star compliant
and be ducted to terminate outside
of the building.
SYMBOLS:
Smoke & Carbon Monoxide
Combination Detector
S/C
Hard wired Smoke Detector
W/backup battery
SD
Hard wired Carbon MonoxideCM
Door Alarm DA
TE
M
P
E
R
E
D
22
'
-
0
1
/
2
"
36
"
48"
Landing
MINISPLIT
CONDENSER
(N)
Bedroom
(N) Living
(N) Kitchen
(N)
Bathroom
(N) Hallway
(N) Closet
Shelving
Shower
94
95
92
96
3' - 1"3' - 2 1/2"
Op
e
n
i
n
g
3'
-
6
"
20"
30
"
ATTIC
ACCESS
TANKLESS
WATERHEATER
36"
84
"
Landing
13' - 1 3/4"9' - 0"
5' - 4 3/4"
50
49
48
93
51
9'
-
7
3
/
4
"
12
'
-
0
"
9' - 0"
5' - 1"
3'
-
0
"
LANDING
S/C
DA
DA
DA
S/C
1.5" Max.
1.5" Max.
1.5" Max.
97
EXISTING WALL
TO BE DEMOLISHED
NEW WALL
WALL LEGEND:
1 HR FIRE RATED
WALL
(E)
Garage
EXISTING GARAGE DOOR TO BE DEMOLISHED
Bedroom
Bath
Bedroom
Bath
Bath
Laundry
Kitchen
Bedroom
Dining
Room
Living
Room
Closet
Heater
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
As indicated
AVD24D019
Debbini, Lubna
Floor Plans +
Schedules
A1
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
-
---
DOOR SCHEDULE
Mark
Phase
Created Width Height Thickness Fire Rating Comments Count U-Factor SHGC
87 NEW 3' - 0"7' - 0"0' - 1 1/2"To be Alarmed - Pool 1
92 NEW 2' - 8"7' - 0"0' - 1 1/2"1
93 NEW 6' - 0"7' - 0"To be Alarmed - Pool 1
94 NEW 2' - 8"7' - 0"0' - 1 1/2"1
95 NEW 2' - 8"7' - 0"0' - 1 1/2"1
96 NEW 6' - 0"6' - 8"0' - 1 1/2"1
97 NEW 3' - 0"7' - 0"0' - 1 1/2"1
WINDOW SCHEDULE
Mark
Phase
Created
Window Size Head
Height Location Comments Count U-Factor SHGC TypeWidthHeight
48 NEW 3' - 0"3' - 10"6' - 8"1 DBL-HUNG
49 NEW 3' - 0"3' - 0"6' - 8"(N) Kitchen 1 SLIDING-D
BL
50 NEW 2' - 2"3' - 6"6' - 8"(N) Bathroom 1 DBL-HUNG
51 NEW 3' - 0"5' - 0"6' - 8"(N) Bedroom 1 DBL-HUNG
52 NEW 3' - 0"4' - 0"6' - 8"1
3/8" = 1'-0"1 Proposed ADU Floorplan
ASPHALT SHINGLES CLASS “A”
(ICC (AC10) ESR-1475,) STYE PER OWNER OR MATCH EXISTING, W/1 LAYER ASTM D 4869 TYPE 1
UNDERLAYMENT AND CORROSION RESISTANT DRIP EDGE, INSTALLED PER MFR. INSTRUCTIONS.
MANUFACTURER - GAF
WINDOW 47, 51 - EGGRESS
3/8" = 1'-0"4 Existing Garage Floor Plan
3/16" = 1'-0"3 Existing House Floor Plan
1108 N Towner St &
#212/13/2024
50STUCCO
New wall materials to match
the existing wall material FIRST FLOOR0' - 0"
B.O.P8' - 0"
T.O.R. ADU11' - 8 3/4"
Vinyl Trim
EXISTING 1 HR FIRE RATED WALL
87
51
STUCCO
Vinyl Trim
VAULTED CEILING
R38
R19R1949
48
R38
R13
R19 R19
94
92
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
As indicated
AVD24D019
Debbini, Lubna
Elevations +
Sections
A2
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
-
---
3/8" = 1'-0"1 ADU West
3/8" = 1'-0"2 ADU South
3/8" = 1'-0"3 ADU East
3/8" = 1'-0"4 ADU North
1/4" = 1'-0"5 Section 1
1/4" = 1'-0"6 Section 2
Natural Stone - Brick Patterned Wall Tile
Stucco (blue)
Vinyl Trim
1 Hour Fire Rated Wall
1108 N Towner St &
#212/13/2024
Wa
s
h
e
r
Dr
y
e
r
REF.
DW
280 CFM Vent
Hood
Min. 50 CFM W/Humidity sensor
exhaust fan W/Min. 5 air changes
per hour.
Fans shall be Energy Star compliant
and be ducted to terminate outside
of the building.
SYMBOLS:
Smoke & Carbon Monoxide
Combination Detector
S/C
Hard wired Smoke Detector
W/backup battery
SD
Hard wired Carbon MonoxideCM
Recessed Can Lights (LED Lights)
Outlet (AFCI)
Outlet GFCI (Ground Fault Circuit
Interrupter)GFCI
Outlet GFCI (Ground Fault Circuit
Interrupter) / WaterproofGFCI
WP
Outlet - Cable / TV /Phone
Switch
Switch W/Occupancy SensorOS
ATTIC VENTILATION CALCULATIONS
ATTIC VENTILATION SHALL NOT BE LESS THAN 1/150
OF THE AREA OF THE SPACE VENTILATED.
TOTAL ROOF AREA VENTILATION AREA REQ.
500 SQ FT 3.5 SQ FT
VENT SIZE & AREA TOTAL No. OF VENTS -> VNET AREA
24" x 12" Dormer = .7 SQ FT 5 VENTS @ .7 SQ FT
REQUIRED < PROVIDED
3.5 SQ FT < 3.5 SQ FT
DORMER
VENT
DORMER
VENT
DORMER
VENT
Roofing Material Type
Class "A" Shingles per
ICC # ESR-1745
To match existing
DORMER
VENT
DORMER
VENT
(N
)
3
:
1
2
(N
)
3
:
1
2
(E) 4 :12
(E
)
4
:
1
2
(E
)
4
:
1
2
1' - 0"
1'
-
0
"
7' - 6"
16' - 10 1/2"
23
'
-
0
"
1'
-
0
"
19' - 0"
5
A2
6
A2
EX
I
S
T
I
N
G
E
A
V
E
T
O
B
E
D
E
M
O
L
I
S
H
E
D
1
H
O
U
R
F
I
R
E
R
A
T
E
D
E
A
V
E
P
E
R
D
E
T
A
I
L
(
I
F
A
P
P
L
I
C
A
B
L
E
)
GFCI
WP
Linen
GF
C
I
WP
GF
C
I
WP
GF
C
I
WP
GFCI
WP
GFCI
WP
GFCI
WP
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
As indicated
AVD24D019
Debbini, Lubna
Roof +
Electrical Plan
A3
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
Checker
---
A. PANEL LOCATIONS
PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY GINITABLE MATERIAL, SUCH AS CLOTHES CLOSETS, OR IN
BATHROOMS [CEC 240-24(D)]
B.NON-METALLIC SHEATHED CABLE [CEC 334]
NON-METALLIC SHEATHED CABLE SHALL BE:
1. PROTECTED BY RIGID METAL CONDUIT, ELECTRICAL METALLIC, TUBING SCHEDULE 80 PVC CONDUIT, PIPE OR OTHER
MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. [CEC 334.15(B)]
2. PROTECTED BY A 1/16” STEEL PLATE OR SLEEVE OR BE NOT LESS THAN 1-1/4" FROM THE NEAREST EDGE OF THE
FRAMING MEMBER, WHEN INSTALLED THROUGH FRAMING MEMBERS. STEEL PLATES ARE SLEEVES ARE REQUIRED ON ALL
DOUBLE SHEAR WALLS WHEN CABLE IS INSTALLED EITHER THROUGH PARALLEL TO FRAMING MEMBERS [CEC 334.17]
3.PROTECTED BY GUARD STRIPS WITHIN 6 FEET OF AN ATTIC ACCESS WHEN NO PERMANENT STAIRS OR LADDERS ARE
PROVIDED [CEC 334.23, 320.23]
4.PROTECTED BY GUARD STRIPS IN THE ENTIRE ATTIC WHEN PERMANENT STAIRS OR LADDER ARE PROVIDED. ACCESS
PANELS OR DOOR FROM THE SECOND FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS
ARE REQUIRED IN THE ENTIRE ATTIC.
5. HAVING A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE [CEC 334.24]
6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12 ” OF EVERY OUTLET BOX, JUNCTION BOX, CABINET
OR FITTING [CEC 334.30]
C.CIRCUITS AND RECEPTACLES
1. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED AS SPECIFIED IN DWELLING UNITS IN ALL AREAS SPECIFIED
IN 210.52 [CEC 406.12]
2.RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACES IS MORE THAN
6 FT FROM AN OUTLET, INCLUDING ANY WALL SPACE 2FT WIDE OR GREATER. NOTE: A FIXED PANEL OF SLIDING GLASS DOOR
IS CONSIDERED WALL SPACE. [CEC 210.52(A)].
3. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A CIRCUITS SHALL BE PROVIDED
[CEC 210.11(C)(1)]. COUNTER SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)] AND INSTALLED:
3.1.AT EACH WALL COUNTER SPACE THAT IS 12IN. OR GREATER [CEC 210.52(C)(1)]
3.2.NO MORE THAN 48IN. O.C. [CEC 210.52(C)(1)]
3.3.MAXIMUM 24IN. FROM THE END OF THE SURFACE [CEC 210.52(C)(1)]
3.4.MAXIMUM 20IN. ABOVE COUNTER SURFACE [CEC 210.52(C)(5)]
3.5.ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN) NOT MORE THAN 12IN. BELOW COUNTER SURFACE
[CEC 210.52(C)(5) EXEMPTION]. AN ISLAND WITH LESS THAN 12IN BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVING
THE COUNTERTOP INTO TWO SEPARATE SPACES [CEC 210.52(C)(2)]
3.6.ON PENINSULAR COUNTER SPACES (ONE RECEPTACLE MIN) NOT MORE THAN 12IN. BELOW COUNTER
SURFACE [CEC 210.52 (C)(5) EXCEPTION]
4.BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT [CEC 210.11(C)(3)] WITH AT LEAST ONE GFCI WALL RECEPTACLES
WITHIN 36IN OF EACH BASIN [CEC 210.8(A)(1); CEC 210.52(D)]
5.LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE SHALL BE PROVIDED [CEC
201.11(C)(2)]. ALL RECEPTACLES WITHIN 6 FT. OF THE SINK SHALL BE GFCI
6.IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED [CEC 210.52(G)]. ALL OTHER GARAGE
RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE NOT READILY ACCESSIBLE SHALL BE GFCI [CEC
210.8(A)(2)]
7.IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE PROVIDED [CEC 210.8(A)(7)]
8.OUTDOOR OUTLETS SHALL BE GFCI [CEC 210.8(A)(3)]. ONE OUTLET SHALL BE INSTALLED AT THE FRONT OF THE
DWELLING AND ONE AT THE REAR OF THE DWELLING. RECEPTACLES SHALL BE ACCESSIBLE AT GRADE LEVEL AND NOT
MORE THAN 6-1/2 FT. ABOVE GRADE [CEC 210.52(E)]
9.ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(4)]
10.ALL INFINISHED BASEMENT RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(5)] OR ARE SERVICE A DEDICATED
APPLIANCES [CEC 210.8(A)(5)]
11. ALL RECEPTACLES WITHIN 6 FT. OF A WET BAR SHALL BE GFCI [CEC 210.8(A)(7)]
12.ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
PARLORS, LABRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS HALLWAYS OR SIMILAR ROOMS OR
AREAS SHALL BE PROTECTED BY COMBINATION-TYPE-ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING SWITCHED
OUTLETS [CEC 210.12(A)]
13.ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1 HP OR 6 AMPS SHALL BE ON A SEPARATE
CIRCUIT.
14.FOR HVAC EQUIPMENT, A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE RECEPTACLE AT THE EQUIPMENT
SHALL BE PROVIDED WITHIN 25 FT OF THE EQUIPMENT [CEC 210.63]. IF LOCATED IN AN UNDER-FLOOR AEA, THE RECEPTACLE
SHALL BE GFCI [CEC 210.8(4)]
15. BASEMENT, GARAGES AND ACCESSORY BUILDINGS. FOR ONE-FAMILY DWELLING, AT LEAST ONE RECEPTACLE OUTLET
SHALL BE INSTALLED IN THE AREAS SPECIFIED IN 210.2(G)(1) THROUGH (3)/ THESE RECEPTACLES SHALL BE IN ADDITION TO
RECEPTACLES REQUIRED FOR SPECIFIC EQUIPMENT.
15.1.GARAGES. IN EACH ATTACHED GARAGE AND IN EACH DETACHED GARAGE WITH ELECTRICAL POWER THE
BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE(S) SHALL NOT SUPPLY OUTLETS OF SIDE OF THE GARAGE. AT LEAST ONE
RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH CAR SPACE.
15.2.ACCESSORY BUILDINGS. IN EACH ACCESSORY BUILDING WITH ELECTRICAL POWER.
15.3.BASEMENT. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT.
D.LIGHTING [CEC 210.70]
1.SWITCHED LIGHTING SHALL BE INSTALLED IN:
1.1 ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL.
1.2 GARAGES.
1.3 AT ALL OUTDOOR ENTRANCES AND EXITS.
1.4 IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR STORAGE.
1.5 NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS, WITH A SWITCH AT THE
ACCESS POINT.
2.LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED FLUORESCENT FIXTURE OR
A SURFACE MOUNTED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT
FIXTURE WITH COMPLETELY ENCLOSED LAMPS. SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF
12IN. FROM THE NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED LIGHTING SHALL
BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A STORAGE SPACE [CEC 410.16(C)]
3. 100% OF THE LUMINARIES IN A KITCHEN MUST BE HIGH EFFICACY.
4. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE
SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR.
5. BEDROOMS, LIVING ROOMS, FAMILY ROOMS AND OTHER ROOMS USED FOR LIVING AND SLEEPING MUST HAVE HIGH
EFFICACY LIGHTING, AND MAY REQUIRE AN OCCUPANT SENSOR WITH A MANUAL-ON/AUTO-OFF FEATURE, OR DIMMERS.
6. EXTERIOR LIGHTING MUST BE HIGH EFFICACY, A PHOTOCELL AND MOTION SENSOR MAY BE INSTALLED.
E.FANS
1. IN BATHROOMS CONTAINING TUBS OR SHOWERS, A FAN CAPABLE OF EXHAUSTING 50 CFM SHALL BE INSTALLED
[ENERGY STANDARDS 150(O)]
2. KITCHEN REQUIRED EXHAUST FAN WITH A MINIMUM 100 CFM DUCTED TO THE EXTERIOR.
3. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50% TO A
MAXIMUM 80% A HUMIDITY CONTROL MAY UTILIZE MANUAL AUTOMATIC
F.SMOKE ALARMS
IN NEW CONSTRUCTION. SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FRONT THE BUILDING WIRING. THE
WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED OR
OVERCURRENT PROTECTION [CRC R314.4]
A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A MINIMUM OF 4 ” IN DIAMETER. THE EXHAUST DUCT SHALL NOT
EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 ’, INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET
SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO (504.3.1.1 & 504.3.1.2 CMC)
ELECTRICAL NOTES
NOTE ALL BATHROOMS FANS:
MINIMUM 50 CFM FAN TESTED AT A STATIC PRESSURE OF .25 WC AND RATED @ 3 SONES OR LESS REQUIRED TO BE INSTALLED
FAN MUST BE ATTACHED TO A MINIMUM 4 ” DUCT AND NO LONGER THAN 70 ’ OF FLEX DUCT. SUBTRACT 15 ’ OF ALLOWED LENGTH
FOR EACH ELBOW.
NOTE ALL KITCHEN RANGE HOODS:
MINIMUM 100 CFM FAN TESTED AT A STATIC PRESSURE OF .25 WC AND RATED @ 3 SONES OR LESS REQUIRED TO BE INSTALLED.
FAN MUST BE ATTACHED TO A MINIMUM 5 ” SMOOTH DUCT AND NO LONGER THAN 85 ’. SUBTRACT 15’ OF ALLOWED LENGTH FOR
EACH ELBOW.
3/8" = 1'-0"1 Roof Plan
3/8" = 1'-0"2 Electrical Plan
ELECTRIC READY NOTES
1.WATER HEATING SYSTEM (WATER HEATER) (SECTION 150.0(N))
A.SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A SPACE AT
LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER
(HPWH) BY MEETING EITHER A OR B LISTED UNDER SECTION 150.0(N).
I.IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER:
A.A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3
CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER.
II. ISOLATE BOTH ENDS OF THE UNUSED CONDUCTOR.
B.A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER
C.A CONDENSATE DRAIN THAT ALLOWS NATURAL DRAINING OF THE WATER HEATER.
D.. IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER HEATER: SEE ADDITIONAL CODE REQUIREMENTS.
B.WHEN A SECOND WATER HEATER IS INSTALLED AS PART OF THE ADDITION SHALL COMPLY WITH SECTION (150.2(A)(D).
1108 N Towner St &
#212/13/2024
FIRST FLOOR
0' - 0"
B.O.P8' - 0"
GRADE-1' - 0"
T.O.R. ADU11' - 8 3/4"
Top of Roof House
13' - 6 1/2"
FIRST FLOOR0' - 0"
B.O.P
8' - 0"
GRADE-1' - 0"
T.O.R. ADU
11' - 8 3/4"
Top of Roof House13' - 6 1/2"
WHITE/GREY STUCCO
WHITE/GREY SIDING
BROWN BRICK
ROOF SLOPE 4:12GREY SHINGLES
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
WHITE WOOD FENCE
FIRST FLOOR0' - 0"
B.O.P
8' - 0"
GRADE
-1' - 0"
T.O.R. ADU
11' - 8 3/4"
Top of Roof House13' - 6 1/2"
FIRST FLOOR0' - 0"
B.O.P8' - 0"
GRADE-1' - 0"
T.O.R. ADU11' - 8 3/4"
Top of Roof House
13' - 6 1/2"
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
1/4" = 1'-0"
AVD24D019
Debbini, Lubna
Main Home
Elevations
A4
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
Checker
---
1/4" = 1'-0"1 Left Elevation (South) - Main Home
1/4" = 1'-0"2 Front Elevation (East) - Main Home
1/4" = 1'-0"3 Right Elevation (North) - Main Home
1/4" = 1'-0"4 Rear Elevation (West) - Main Home
1108 N Towner St &
#212/13/2024
GENERAL NOTES AND
DETAILS
S-1
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
12.11.23
AD
U
C
O
N
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2023 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
#
2
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
1108 N Towner St &
#212/13/2024
’
’
’
’
’
’
’’
DEPTUY INSPECTION
AND STRUCTURAL
OBSERVATION NOTES
S-2
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
12.11.23
AD
U
C
O
N
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2023 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
#
2
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
1108 N Towner St &
#212/13/2024
GENERAL DETAILS
S-3
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
12.11.23
AD
U
C
O
N
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2023 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
#
2
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
1108 N Towner St &
#212/13/2024
TABLE 1 - SHEAR WALL NAILING SCHEDULE PER TABLES 4.3A AND 4.3C OF NDS' SDPWS-2021
PL
A
T
E
L
I
N
E
PLATE LINE PLATE LINE
PL
A
T
E
L
I
N
E
TABLE 2 - HOLDOWN SCHEDULE
"HOLDOWN" AT NEW FOOTING
AL
L
S
I
L
L
P
L
A
T
E
S
I
N
TH
I
S
C
O
L
U
M
N
A
R
E
2
x
NOTE SILL
PLATES SIZES IN
THIS COLUMN
WOOD SHEAR WALL
FRAMING AND NOTES
S-4
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
12.11.23
AD
U
C
O
N
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2023 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
#
2
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
1108 N Towner St &
#212/13/2024
SLAB ON GRADE
FOUNDATION AND
ROOF FRAMING PLAN
S-5
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
11.06.24
AD
U
C
ON
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2024 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
PC 2 10.17.24
PC 3 11.06.24
IF EXISTING FOUNDATION IS NOT FOUND OR INADEQUATE TO
MEET MINIMUM AND NEW FOUNDATION IS REQUIRED TO BE
CONSTRUCTED, NO CONSTRUCTION BEYOND PROPERTY LINE
MAY BE DONE.
1108 N Towner St &
#212/13/2024
TYPICAL NAILING SCHEDULE 2 2
19
4
6
11 7 3
2 18 10
(N) STUD WALL AT (E) STUD WALL
5 13
16 12 20 SLAB ON GRADE FOOTINGS
A- EXTERIOR FOOTINGB- EXTERIOR FOOTING W/ CURB
(N) FOOTING ATTACHMENT TO (E) FOOTING
(N) HOLDOWN AT (E) FOUNDATION(N) SHEAR WALL AT (E) FOOTINGS (N) INTERIOR PAD FOOTING AT (E) SLAB ON GRADE
ROOF RAFTER AT EXTERIOR WALL
SHEAR WALL PARALLEL TO ROOF RAFTER
WOOD POST AT CONCRETE SLAB ON GRADE
WOOD BEAM AT STUD WALL
SHEATING AT CALIFORNIA FRAMING14 RIDGE BEAM(N) BEAM AT (E) ROOF
PLATE LINE
PL
A
T
E
L
I
N
E
KING POST DETAIL
SECTIONS AND
DETAILS
S-6
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
12.11.23
AD
U
C
O
N
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2023 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
#
2
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
1108 N Towner St &
#212/13/2024
19
16
517
8
14
13
4
610
15 11 7 3
2
1 9
18
1220
WOOD BEAM AT WOOD POST
(N) PAD FOOTING UNDER (E) FOOTING
SECTIONS AND
DETAILS
S-7
JOB NO.:
DATE:
SCALE:
SHEET TITLE:
SHEET NUMBER:
AS INDICATED
12.11.23
AD
U
C
O
N
V
E
R
S
I
O
N
REVISIONS:
PC 1 12.11.23
23064
818.939.7870
ak@keshishians.com
2023 KESHISHIAN ENGINEERING. THE ABOVE DRAWINGS, SPECIFICATIONS, DESIGNS & ARRANGEMENTS REPRESENTED ARE & SHALL REMAIN THE PROPERTY OF THE ENGINEER OF RECORD, & NO PART THEREFORE SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED & DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. VISUAL CONTACT WITH THESE DRAWINGS & SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF THESE RESTRICTIONS.C
11
0
8
N
T
O
W
N
E
R
S
T
#
2
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
1108 N Towner St &
#212/13/2024
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
AVD24D019
Debbini, Lubna
Green Notes
GRN1
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
Checker
---
1108 N Towner St &
#212/13/2024
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
AVD24D019
Debbini, Lubna
Title 24 Energy
Analysis
T24
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
Checker
---
1108 N Towner St &
#212/13/2024
SHEET TITLE:
SCALE:
SHEET NO.
PR
O
J
E
C
T
DA
T
E
RE
V
I
S
I
O
N
PROJECT NUMBER:
OWNER / CLIENT:
DATE ISSUED:
DATE SUBMITTED:
DRAWN BY:
CHECKED BY:
THESE DRAWINGS ARE THE PROPERTY
OF TREEIUM INC AND SHALL NOT BE
USED ON ANY OTHER WORK EXCEPT
BY AGREEMENT WITH TREEIUM INC
48
2
1
L
A
N
K
E
R
S
H
I
M
B
L
V
D
S
T
E
F
#
4
4
5
NO
R
T
H
H
O
L
L
Y
W
O
O
D
,
C
A
31
0
.
6
9
4
.
0
8
3
5
WW
W
.
A
V
D
E
S
I
G
N
.
L
A
AV
D
E
S
I
G
N
AVD24D019
Debbini, Lubna
Title 24 Energy
Analysis
T24.2
To
w
n
e
r
A
D
U
11
0
8
N
T
o
w
n
e
r
S
t
&
1
1
0
8
N
To
w
n
e
r
S
t
r
e
e
t
#
2
Sa
n
t
a
A
n
a
,
C
A
9
2
7
0
3
ER/CB
Checker
---
1108 N Towner St &
#212/13/2024
K e s h i s h i a n E n g i n e e r i n g
( 8 1 8 ) 9 3 9 . 7 8 7 0
a k @ k e s h i s h i a n s . c o m
ADU C ONVERSION
S TRUCTURAL C ALCULATIONS
PC 1
1108 N T OWNER ST
S ANTA A NA , CA 92703
KE Job No. 23064
12/11/23
Page 1
1108 N Towner St &
#212/13/2024
ASCE/SEI 7-16
DEAD LOAD GRAVITY SEISMIC NOTES
Roofing 3.0 3.0 psf
Sheathing 4.0 4.0 psf
Framing 4.0 4.0 psf
Insulation 1.0 1.0 psf
Ceiling Joists 1.0 1.0 psf
Gyp Board 1.0 1.0 psf
Misc. 1.0 1.0 psf
TOTAL DEAD LOAD 15.0 15.0 psf
LIVE LOAD
Roof Live Load 20.0 psf
DEAD LOAD GRAVITY SEISMIC NOTES
Framing 2.0 2.0 psf
Ceiling 2.0 2.0 psf
Insulation 0.5 0.5 psf
Misc. 0.5 0.5 psf
TOTAL DEAD LOAD 5.0 5.0 psf
LIVE LOAD
Roof Live Load 10.0 psf
DEAD LOAD GRAVITY SEISMIC NOTES
Stucco 10.0 10.0 psf
1/2" Plywood 1.5 1.5 psf
Batt Insulation 1.0 1.0 psf
Framing 1.0 1.0 psf
Interior Gypboard 2.0 2.0 psf
Miscellaneous 0.5 0.5 psf
TOTAL DEAD LOAD 16.0 8.0 psf
Non-Reducible
ROOF RAFTERS
Reducible
DESIGN CRITERIA
1108 N TOWNER ST KE Job # 23064JOB NAME:
Ceiling Joists
1/2 Wall Height for seismic
WOOD FRAMED WALLS - STUCCO
Page 2
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RR
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase
Allowable Stress Design
Douglas Fir-Larch
No.2
900
900
1350
625
1600
580
180
575 31.21
Analysis Method :
Eminbend - xx ksi
Wood Species :
Wood Grade :
Fb +
psi
psi
Fv psi
Fb -
Ft psi
Fc - Prll psi
psiFc - Perp
E : Modulus of Elasticity
Ebend- xx ksi
Density pcf
Load Combination :ASCE 7-16
.Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft
.DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio 0.726: 1
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 5.750 ft
45.11 psi=
=
1,681.88 psi
2x6Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1=
Load Combination +D+Lr
=
=
=
225.00 psi==
Section used for this span 2x6
Maximum Shear Stress Ratio 0.201 : 1
0.000 ft=
=
1,221.07 psi
Maximum Deflection
0 <240
249
Ratio =0 <180
Max Downward Transient Deflection 0.316 in 436Ratio =>=240
Max Upward Transient Deflection 0.000 in Ratio =
Max Downward Total Deflection 0.554 in Ratio =>=180
Max Upward Total Deflection 0.000 in
fb: Actual
Fb: Allowable
fv: Actual
Fv: Allowable
.Maximum Forces & Stresses for Load Combinations
Span #
Moment ValuesLoad Combination
C i C LC CCCF/V mr td
Shear ValuesMax Stress Ratios
M CV fbM fvF'b V F'vSegment Length
D Only 0.00 0.00 0.000.00
1.00Length = 11.50 ft 1 0.432 0.119 0.90 1.300 1.15 1.00 1.00 0.33 523.32 1210.95 0.11 162.001.00 19.33
1.00+D+Lr 1.300 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 11.50 ft 1 0.726 0.201 1.25 1.300 1.15 1.00 1.00 0.77 1,221.07 1681.88 0.25 225.001.00 45.11
1.00+D+0.750Lr 1.300 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 11.50 ft 1 0.622 0.172 1.25 1.300 1.15 1.00 1.00 0.66 1,046.63 1681.88 0.21 225.001.00 38.67
1.00+0.60D 1.300 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 11.50 ft 1 0.146 0.040 1.60 1.300 1.15 1.00 1.00 0.20 313.99 2152.80 0.06 288.001.00 11.60
.
Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl
Overall Maximum Deflections
+D+Lr 1 0.5537 5.792 0.0000 0.000
.
Page 3
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RR
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Load Combination Support 1 Support 2
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Overall MAXimum 0.268 0.268
Overall MINimum 0.153 0.153
D Only 0.115 0.115
+D+Lr 0.268 0.268
+D+0.750Lr 0.229 0.229
+0.60D 0.069 0.069
Lr Only 0.153 0.153
Page 4
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:CJ
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase
Allowable Stress Design
Douglas Fir-Larch
No.2
900
900
1350
625
1600
580
180
575 31.21
Analysis Method :
Eminbend - xx ksi
Wood Species :
Wood Grade :
Fb +
psi
psi
Fv psi
Fb -
Ft psi
Fc - Prll psi
psiFc - Perp
E : Modulus of Elasticity
Ebend- xx ksi
Density pcf
Load Combination :ASCE 7-16
.Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0050, Lr = 0.010 ksf, Tributary Width = 1.330 ft
.DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio 0.191: 1
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 4.500 ft
14.77 psi=
=
1,681.88 psi
2x6Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1=
Load Combination +D+Lr
=
=
=
225.00 psi==
Section used for this span 2x6
Maximum Shear Stress Ratio 0.066 : 1
8.573 ft=
=
320.52 psi
Maximum Deflection
0 <240
1213
Ratio =0 <180
Max Downward Transient Deflection 0.059 in 1819Ratio =>=240
Max Upward Transient Deflection 0.000 in Ratio =
Max Downward Total Deflection 0.089 in Ratio =>=180
Max Upward Total Deflection 0.000 in
fb: Actual
Fb: Allowable
fv: Actual
Fv: Allowable
.Maximum Forces & Stresses for Load Combinations
Span #
Moment ValuesLoad Combination
C i C LC CCCF/V mr td
Shear ValuesMax Stress Ratios
M CV fbM fvF'b V F'vSegment Length
D Only 0.00 0.00 0.000.00
1.00Length = 9.0 ft 1 0.088 0.030 0.90 1.300 1.15 1.00 1.00 0.07 106.84 1210.95 0.03 162.001.00 4.92
1.00+D+Lr 1.300 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 9.0 ft 1 0.191 0.066 1.25 1.300 1.15 1.00 1.00 0.20 320.52 1681.88 0.08 225.001.00 14.77
1.00+D+0.750Lr 1.300 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 9.0 ft 1 0.159 0.055 1.25 1.300 1.15 1.00 1.00 0.17 267.10 1681.88 0.07 225.001.00 12.31
1.00+0.60D 1.300 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 9.0 ft 1 0.030 0.010 1.60 1.300 1.15 1.00 1.00 0.04 64.10 2152.80 0.02 288.001.00 2.95
.
Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl
Overall Maximum Deflections
+D+Lr 1 0.0890 4.533 0.0000 0.000
.
Page 5
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:CJ
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Load Combination Support 1 Support 2
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Overall MAXimum 0.090 0.090
Overall MINimum 0.060 0.060
D Only 0.030 0.030
+D+Lr 0.090 0.090
+D+0.750Lr 0.075 0.075
+0.60D 0.018 0.018
Lr Only 0.060 0.060
Page 6
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-1
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Beam Bracing :Beam is Fully Braced against lateral-torsional buckling
Allowable Stress Design
Douglas Fir-Larch
No.1
1,350.0
1,350.0
925.0
625.0
1,600.0
580.0
170.0
675.0 31.210
Analysis Method :
Eminbend - xx ksi
Wood Species :
Wood Grade :
Fb +
psi
psi
Fv psi
Fb -
Ft psi
Fc - Prll psi
psiFc - Perp
E : Modulus of Elasticity
Ebend- xx ksi
Density pcf
Load Combination :ASCE 7-16
.Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 12.0 ft
.DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio 0.693: 1
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 7.500 ft
65.43 psi=
=
1,687.50 psi
6x12Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1=
Load Combination +D+Lr
=
=
=
212.50 psi==
Section used for this span 6x12
Maximum Shear Stress Ratio 0.308 : 1
14.069 ft=
=
1,169.27 psi
Maximum Deflection
0 <240
417
Ratio =0 <180
Max Downward Transient Deflection 0.247 in 730Ratio =>=240
Max Upward Transient Deflection 0.000 in Ratio =
Max Downward Total Deflection 0.431 in Ratio =>=180
Max Upward Total Deflection 0.000 in
fb: Actual
Fb: Allowable
fv: Actual
Fv: Allowable
.Maximum Forces & Stresses for Load Combinations
Span #
Moment ValuesLoad Combination
C i C LC CCCF/V mr td
Shear ValuesMax Stress Ratios
M CV fbM fvF'b V F'vSegment Length
D Only 0.00 0.00 0.000.00
1.00Length = 15.0 ft 1 0.412 0.183 0.90 1.000 1.00 1.00 1.00 5.06 501.12 1215.00 1.18 153.001.00 28.04
1.00+D+Lr 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 15.0 ft 1 0.693 0.308 1.25 1.000 1.00 1.00 1.00 11.81 1,169.27 1687.50 2.76 212.501.00 65.43
1.00+D+0.750Lr 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 15.0 ft 1 0.594 0.264 1.25 1.000 1.00 1.00 1.00 10.13 1,002.23 1687.50 2.36 212.501.00 56.09
1.00+0.60D 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 15.0 ft 1 0.139 0.062 1.60 1.000 1.00 1.00 1.00 3.04 300.67 2160.00 0.71 272.001.00 16.83
.
Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl
Overall Maximum Deflections
+D+Lr 1 0.4314 7.555 0.0000 0.000
.
Page 7
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-1
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Load Combination Support 1 Support 2
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Overall MAXimum 3.150 3.150
Overall MINimum 1.800 1.800
D Only 1.350 1.350
+D+Lr 3.150 3.150
+D+0.750Lr 2.700 2.700
+0.60D 0.810 0.810
Lr Only 1.800 1.800
Page 8
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-2
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Beam Bracing :Beam is Fully Braced against lateral-torsional buckling
Allowable Stress Design
iLevel Truss Joist
Parallam PSL 2.2E
2900
2900
2900
750
2200
1118.19
290
2025 45.07
Analysis Method :
Eminbend - xx ksi
Wood Species :
Wood Grade :
Fb +
psi
psi
Fv psi
Fb -
Ft psi
Fc - Prll psi
psiFc - Perp
E : Modulus of Elasticity
Ebend- xx ksi
Density pcf
Load Combination :ASCE 7-16
.Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 8.0 ft
Point Load : D = 1.30, Lr = 1.80 k @ 11.50 ft, (RB-1)
Uniform Load : D = 0.0050, Lr = 0.010 ksf, Tributary Width = 12.0 ft, (CEILING)
.DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio 0.710: 1
Load Combination +D+Lr
Span # where maximum occurs Span # 1
Location of maximum on span 11.500 ft
97.01 psi=
=
3,563.50 psi
7x14Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1=
Load Combination +D+Lr
=
=
=
362.50 psi==
Section used for this span 7x14
Maximum Shear Stress Ratio 0.268 : 1
0.000 ft=
=
2,531.68 psi
Maximum Deflection
0 <240
227
Ratio =0 <180
Max Downward Transient Deflection 0.729 in 378Ratio =>=240
Max Upward Transient Deflection 0.000 in Ratio =
Max Downward Total Deflection 1.215 in Ratio =>=180
Max Upward Total Deflection 0.000 in
fb: Actual
Fb: Allowable
fv: Actual
Fv: Allowable
.Maximum Forces & Stresses for Load Combinations
Span #
Moment ValuesLoad Combination
C i C LC CCCF/V mr td
Shear ValuesMax Stress Ratios
M CV fbM fvF'b V F'vSegment Length
D Only 0.00 0.00 0.000.00
1.00Length = 23.0 ft 1 0.396 0.148 0.90 0.983 1.00 1.00 1.00 19.38 1,016.90 2565.72 2.52 261.001.00 38.63
1.00+D+Lr 0.983 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 23.0 ft 1 0.710 0.268 1.25 0.983 1.00 1.00 1.00 48.24 2,531.68 3563.50 6.34 362.501.00 97.01
1.00+D+0.750Lr 0.983 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 23.0 ft 1 0.604 0.227 1.25 0.983 1.00 1.00 1.00 41.03 2,152.98 3563.50 5.38 362.501.00 82.41
1.00+0.60D 0.983 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00
1.00Length = 23.0 ft 1 0.134 0.050 1.60 0.983 1.00 1.00 1.00 11.63 610.14 4561.28 1.51 464.001.00 23.18
.
Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl
Overall Maximum Deflections
+D+Lr 1 1.2150 11.584 0.0000 0.000
.
Page 9
1108 N Towner St &
#212/13/2024
Wood Beam
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-2
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Load Combination Support 1 Support 2
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Overall MAXimum 6.840 6.840
Overall MINimum 4.120 4.120
D Only 2.720 2.720
+D+Lr 6.840 6.840
+D+0.750Lr 5.810 5.810
+0.60D 1.632 1.632
Lr Only 4.120 4.120
Page 10
1108 N Towner St &
#212/13/2024
Wall Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:TYP CONT FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
1.50
Analysis Settings
250.0ksi
No
ksfAllowable Soil Bearing =
=
2.50
60.0
2,850.0
150.0 =0.30
Flexure =0.90
Shear =
Valuesj
0.00090
Soil Passive Resistance (for Sliding)
1.0
1.0
=
Increases based on footing Width
Allow. Pressure Increase per foot of width = ksf
when footing is wider than = ft:
=
AutoCalc Footing Weight as DL Yes
Adjusted Allowable Bearing Pressure ksf=1.50
when base footing is below ft
pcf
Increase Bearing By Footing Weight
= pcf
Min. Overturning Safety Factor
=
: 1
Increases based on footing Depth0.750 =
Soil/Concrete Friction Coeff.
Ec : Concrete Elastic Modulus
Min. Sliding Safety Factor
=
=
: 1
Reference Depth below Surface ft
=Allow. Pressure Increase per foot of depth ksf
=
=
=
Concrete Density
=
Min Allow % Temp Reinf.
ksif'c : Concrete 28 day strength
fy : Rebar Yield ksi
Min Steel % Bending Reinf.
Dimensions
Footing Width 1 ft=
Wall center offset
from center of footing 0 in
=
=
Wall Thickness 4.0 in
Footing Thickness 24.0 in=
Rebar Centerline to Edge of Concrete...
= inat Bottom of footing 3.0
Reinforcing
#
Bars along X-X Axis
Reinforcing Bar Size
=
4
# of Bars in 12" Width
=
2
Applied Loads
1.0 0.20 0.0
D Lr
ksf
L S
P : Column Load
OB : Overburden =
k
W E
M-zz
V-x =k
k-ft
Vx applied = in above top of footing
=
H
=
Page 11
1108 N Towner St &
#212/13/2024
Wall Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:TYP CONT FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
DESIGN SUMMARY Design OK
Governing Load CombinationFactor of Safety Item Applied Capacity
PASS 1.0 Soil Bearing 1.50 ksf 1.50 ksf +D+Lr
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
Utilization Ratio Item Applied Capacity Governing Load Combination
PASS 0.002826 Z Flexure (+X) 0.1044 k-ft 36.953 k-ft +1.20D+1.60Lr
PASS 0.001759 Z Flexure (-X) 0.0650 k-ft 36.953 k-ft +0.90D
PASS n/a 1-way Shear (+X) 0.0 psi 75.0 psi n/a
PASS 0.0 1-way Shear (-X)0.0 psi 0.0 psi n/a
Detailed Results
Rotation Axis &
Xecc
Actual Soil Bearing Stress Actual / Allowable
Soil Bearing
Gross Allowable -X +X RatioLoad Combination...
, D Only 1.50 ksf 1.30 ksf 1.30 ksf 0.8670.0 in
, +D+Lr 1.50 ksf 1.50 ksf 1.50 ksf 1.0000.0 in
, +D+0.750Lr 1.50 ksf 1.450 ksf 1.450 ksf 0.9670.0 in
, +0.60D 1.50 ksf 0.780 ksf 0.780 ksf 0.5200.0 in
Rotation Axis &
Overturning Stability Units :k-ft
Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio
Footing Has NO Overturning
Force Application Axis
Sliding Stability
Load Combination...StatusSliding Force Resisting Force Sliding SafetyRatio
Footing Has NO Sliding
Flexure Axis & Load Combination k-ft
As Req'd
Footing Flexure
Tension @ Bot.Which Actual As
Statusk-ft
Mu
Side ? or Top ?in^2in^2 in^2
Gvrn. As Phi*Mn
, +1.40D 0.1011 -X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.40D 0.1011 +X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.20D+0.50Lr 0.09222 -X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.20D+0.50Lr 0.09222 +X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.20D 0.08667 -X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.20D 0.08667 +X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.20D+1.60Lr 0.1044 -X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +1.20D+1.60Lr 0.1044 +X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +0.90D 0.065 -X Bottom 0.2592 Min Temp %0.4 36.953 OK
, +0.90D 0.065 +X Bottom 0.2592 Min Temp %0.4 36.953 OK
One Way Shear Units :k
Vu @ +XLoad Combination... Vu @ -X Vu:Max Vu / Phi*VnPhi Vn Status
+1.40D 0 0 0 75 0psipsipsipsi OK
+1.20D+0.50Lr 0 0 0 75 0psipsipsipsi OK
+1.20D 0 0 0 75 0psipsipsipsi OK
+1.20D+1.60Lr 0 0 0 75 0psipsipsipsi OK
+0.90D 0 0 0 75 0psipsipsipsi OK
Page 12
1108 N Towner St &
#212/13/2024
General Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-1 FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
1.50
Analysis Settings
250.0ksi
No
ksfAllowable Soil Bearing =
=
2.50
60.0
2,850.0
145.0 =0.30
Flexure =0.90
Shear =
Valuesj
0.00180
Soil Passive Resistance (for Sliding)
1.0
=
Increases based on footing plan dimension
Add Pedestal Wt for Soil Pressure No:
Use Pedestal wt for stability, mom & shear No:
Allowable pressure increase per foot of depth
= ksf
when max. length or width is greater than
= ft
:
=
Add Ftg Wt for Soil Pressure Yes
Yes:Use ftg wt for stability, moments & shears
when footing base is below ft
pcf
Increase Bearing By Footing Weight
= pcf
Min. Overturning Safety Factor
=
: 1
Increases based on footing Depth0.750
=
Soil/Concrete Friction Coeff.
Ec : Concrete Elastic Modulus
=
=Footing base depth below soil surface ft
=Allow press. increase per foot of depth ksf
=
: 11.0Min. Sliding Safety Factor =
=
Concrete Density
=
Min Allow % Temp Reinf.
ksif'c : Concrete 28 day strength
fy : Rebar Yield ksi
Min Steel % Bending Reinf.
#
Dimensions
Width parallel to X-X Axis 2.0 ft
Length parallel to Z-Z Axis
=
2.0 ft
=
Pedestal dimensions...
px : parallel to X-X Axis in
pz : parallel to Z-Z Axis in
Height =
=
in
Footing Thickness
=
18.0 in=
Rebar Centerline to Edge of Concrete...
= inat Bottom of footing 3.0
Reinforcing
#
Bars parallel to X-X Axis
Reinforcing Bar Size
=
4
Number of Bars
=
4
Bars parallel to Z-Z Axis
Reinforcing Bar Size =4
Number of Bars =4
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
1.5 2.0
D Lr
ksf
L S
P : Column Load
OB : Overburden =
k
W E
M-zz
V-x
=
=k
V-z k
M-xx =
k-ft=
k-ft
H
=
Page 13
1108 N Towner St &
#212/13/2024
General Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-1 FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
DESIGN SUMMARY Design OK
Governing Load CombinationMin. Ratio Item Applied Capacity
PASS 0.7287 Soil Bearing 1.093 ksf 1.50 ksf +D+Lr about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.02390 Z Flexure (+X) 0.6250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS 0.02390 Z Flexure (-X) 0.6250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS 0.02390 X Flexure (+Z) 0.6250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS 0.02390 X Flexure (-Z) 0.6250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS n/a 1-way Shear (+X) 0.0 psi 75.0 psi n/a
PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a
PASS n/a 1-way Shear (+Z) 0.0 psi 75.0 psi n/a
PASS n/a 1-way Shear (-Z) 0.0 psi 75.0 psi n/a
PASS n/a 2-way Punching 3.420 psi 75.0 psi +1.20D+1.60Lr
Detailed Results
Rotation Axis &ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow
Soil Bearing
(in)Gross Allowable Bottom, -Z Top, +Z Left, -X Right, +X RatioLoad Combination...
X-X, D Only 1.50 n/a0.5925 0.5925 n/a 0.3950.0n/a
X-X, +D+Lr 1.50 n/a1.093 1.093 n/a 0.7290.0n/a
X-X, +D+0.750Lr 1.50 n/a0.9675 0.9675 n/a 0.6450.0n/a
X-X, +0.60D 1.50 n/a0.3555 0.3555 n/a 0.2370.0n/a
Z-Z, D Only 1.50 0.5925n/a n/a 0.5925 0.395n/a0.0
Z-Z, +D+Lr 1.50 1.093n/a n/a 1.093 0.729n/a0.0
Z-Z, +D+0.750Lr 1.50 0.9675n/a n/a 0.9675 0.645n/a0.0
Z-Z, +0.60D 1.50 0.3555n/a n/a 0.3555 0.237n/a0.0
Rotation Axis &
Overturning Stability
Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio
Footing Has NO Overturning
Force Application Axis
Sliding Stability All units k
Load Combination...StatusSliding Force Resisting Force Stability Ratio
Footing Has NO Sliding
Flexure Axis & Load Combination in^2 in^2 in^2 k-ft
As Req'd
Footing Flexure
Tension
k-ft
Actual As StatusMu Side
Surface
Gvrn. As Phi*Mn
X-X, +1.40D 0.2625 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.40D 0.2625 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+0.50Lr 0.350 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+0.50Lr 0.350 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D 0.2250 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D 0.2250 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+1.60Lr 0.6250 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+1.60Lr 0.6250 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +0.90D 0.1688 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +0.90D 0.1688 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.40D 0.2625 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.40D 0.2625 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D+0.50Lr 0.350 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D+0.50Lr 0.350 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D 0.2250 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D 0.2250 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Page 14
1108 N Towner St &
#212/13/2024
General Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-1 FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Flexure Axis & Load Combination in^2 in^2 in^2 k-ft
As Req'd
Footing Flexure
Tension
k-ft
Actual As StatusMu Side
Surface
Gvrn. As Phi*Mn
Z-Z, +1.20D+1.60Lr 0.6250 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D+1.60Lr 0.6250 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +0.90D 0.1688 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +0.90D 0.1688 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
One Way Shear
Vu @ +XLoad Combination... Vu @ -X Vu @ -Z Vu @ +Z Vu:Max Vu / Phi*VnPhi Vn Status
+1.40D 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+1.20D+0.50Lr 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+1.20D 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+1.20D+1.60Lr 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+0.90D 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
Vu / Phi*Vn
Two-Way "Punching" Shear All units k
StatusVu Phi*VnLoad Combination...
+1.40D 1.44 150.00 0.009576 OKpsipsi
+1.20D+0.50Lr 1.92 150.00 0.01277 OKpsipsi
+1.20D 1.23 150.00 0.008208 OKpsipsi
+1.20D+1.60Lr 3.42 150.00 0.0228 OKpsipsi
+0.90D 0.92 150.00 0.006156 OKpsipsi
Page 15
1108 N Towner St &
#212/13/2024
General Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-2 FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
1.50
Analysis Settings
250.0ksi
No
ksfAllowable Soil Bearing =
=
2.50
60.0
2,850.0
145.0 =0.30
Flexure =0.90
Shear =
Valuesj
0.00180
Soil Passive Resistance (for Sliding)
1.0
=
Increases based on footing plan dimension
Add Pedestal Wt for Soil Pressure No:
Use Pedestal wt for stability, mom & shear No:
Allowable pressure increase per foot of depth
= ksf
when max. length or width is greater than
= ft
:
=
Add Ftg Wt for Soil Pressure Yes
Yes:Use ftg wt for stability, moments & shears
when footing base is below ft
pcf
Increase Bearing By Footing Weight
= pcf
Min. Overturning Safety Factor
=
: 1
Increases based on footing Depth0.750
=
Soil/Concrete Friction Coeff.
Ec : Concrete Elastic Modulus
=
=Footing base depth below soil surface ft
=Allow press. increase per foot of depth ksf
=
: 11.0Min. Sliding Safety Factor =
=
Concrete Density
=
Min Allow % Temp Reinf.
ksif'c : Concrete 28 day strength
fy : Rebar Yield ksi
Min Steel % Bending Reinf.
#
Dimensions
Width parallel to X-X Axis 2.50 ft
Length parallel to Z-Z Axis
=
2.50 ft
=
Pedestal dimensions...
px : parallel to X-X Axis in
pz : parallel to Z-Z Axis in
Height =
=
in
Footing Thickness
=
18.0 in=
Rebar Centerline to Edge of Concrete...
= inat Bottom of footing 3.0
Reinforcing
#
Bars parallel to X-X Axis
Reinforcing Bar Size
=
4
Number of Bars
=
5.0
Bars parallel to Z-Z Axis
Reinforcing Bar Size =4
Number of Bars =5.0
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
3.0 4.0
D Lr
ksf
L S
P : Column Load
OB : Overburden =
k
W E
M-zz
V-x
=
=k
V-z k
M-xx =
k-ft=
k-ft
H
=
Page 16
1108 N Towner St &
#212/13/2024
General Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-2 FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
DESIGN SUMMARY Design OK
Governing Load CombinationMin. Ratio Item Applied Capacity
PASS 0.8920 Soil Bearing 1.338 ksf 1.50 ksf +D+Lr about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.04780 Z Flexure (+X) 1.250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS 0.04780 Z Flexure (-X) 1.250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS 0.04780 X Flexure (+Z) 1.250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS 0.04780 X Flexure (-Z) 1.250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60Lr
PASS n/a 1-way Shear (+X) 0.0 psi 75.0 psi n/a
PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a
PASS n/a 1-way Shear (+Z) 0.0 psi 75.0 psi n/a
PASS n/a 1-way Shear (-Z) 0.0 psi 75.0 psi n/a
PASS n/a 2-way Punching 8.333 psi 75.0 psi +1.20D+1.60Lr
Detailed Results
Rotation Axis &ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow
Soil Bearing
(in)Gross Allowable Bottom, -Z Top, +Z Left, -X Right, +X RatioLoad Combination...
X-X, D Only 1.50 n/a0.6975 0.6975 n/a 0.4650.0n/a
X-X, +D+Lr 1.50 n/a1.338 1.338 n/a 0.8920.0n/a
X-X, +D+0.750Lr 1.50 n/a1.178 1.178 n/a 0.7850.0n/a
X-X, +0.60D 1.50 n/a0.4185 0.4185 n/a 0.2790.0n/a
Z-Z, D Only 1.50 0.6975n/a n/a 0.6975 0.465n/a0.0
Z-Z, +D+Lr 1.50 1.338n/a n/a 1.338 0.892n/a0.0
Z-Z, +D+0.750Lr 1.50 1.178n/a n/a 1.178 0.785n/a0.0
Z-Z, +0.60D 1.50 0.4185n/a n/a 0.4185 0.279n/a0.0
Rotation Axis &
Overturning Stability
Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio
Footing Has NO Overturning
Force Application Axis
Sliding Stability All units k
Load Combination...StatusSliding Force Resisting Force Stability Ratio
Footing Has NO Sliding
Flexure Axis & Load Combination in^2 in^2 in^2 k-ft
As Req'd
Footing Flexure
Tension
k-ft
Actual As StatusMu Side
Surface
Gvrn. As Phi*Mn
X-X, +1.40D 0.5250 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.40D 0.5250 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+0.50Lr 0.70 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+0.50Lr 0.70 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D 0.450 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D 0.450 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+1.60Lr 1.250 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +1.20D+1.60Lr 1.250 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +0.90D 0.3375 +Z Bottom 0.3888 Min Temp %0.40 26.153 OK
X-X, +0.90D 0.3375 -Z Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.40D 0.5250 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.40D 0.5250 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D+0.50Lr 0.70 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D+0.50Lr 0.70 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D 0.450 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D 0.450 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Page 17
1108 N Towner St &
#212/13/2024
General Footing
Keshishian EngineeringLic. # : KW-06012794
DESCRIPTION:RB-2 FOOTING
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.10.31
File: 23064.ec6
Flexure Axis & Load Combination in^2 in^2 in^2 k-ft
As Req'd
Footing Flexure
Tension
k-ft
Actual As StatusMu Side
Surface
Gvrn. As Phi*Mn
Z-Z, +1.20D+1.60Lr 1.250 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +1.20D+1.60Lr 1.250 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +0.90D 0.3375 -X Bottom 0.3888 Min Temp %0.40 26.153 OK
Z-Z, +0.90D 0.3375 +X Bottom 0.3888 Min Temp %0.40 26.153 OK
One Way Shear
Vu @ +XLoad Combination... Vu @ -X Vu @ -Z Vu @ +Z Vu:Max Vu / Phi*VnPhi Vn Status
+1.40D 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+1.20D+0.50Lr 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+1.20D 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+1.20D+1.60Lr 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
+0.90D 0.00 0.00 0.00 0.00 0.00 75.00 0.00psipsipsipsipsipsi OK
Vu / Phi*Vn
Two-Way "Punching" Shear All units k
StatusVu Phi*VnLoad Combination...
+1.40D 3.50 150.00 0.02333 OKpsipsi
+1.20D+0.50Lr 4.67 150.00 0.03111 OKpsipsi
+1.20D 3.00 150.00 0.02 OKpsipsi
+1.20D+1.60Lr 8.33 150.00 0.05556 OKpsipsi
+0.90D 2.25 150.00 0.015 OKpsipsi
Page 18
1108 N Towner St &
#212/13/2024
! ! "##$#"#%&'()*%
##"# +,
--./010234567089:08;59;0<5;:0=<0>?@.A:0B8<
C;9D9EF6:0C35GD9EF6H0AAI@JK>>>>:0L--@I//.J?/A
M;96 NO
M6PDG50=3F60Q6R6765S60M3SET659 U
VWOX Y
QDPZ0=;96G37[\\
8D960=];PP X!"#^
_
2[`6 a;]E6 M6PS7D`9D35
NY
VWb" ^!N _
NYc
VWb" ^! N _
cYO
X ! ###"
"##X
d
X ! ###"
Nc e" #"N
U
"##X
d e" #" N
U
2[`6 a;]E6 M6PS7D`9D35
V "##X
d
f
g
#!!N
g"##X
d
#!! N
U Ncc
VW+" #
g U
#!! U
U
NYY
! +" #
hi d iX
bh NY #+X " ^N _
j NY g "!Xk ^l#f!, cNf_##
cd g ##"^N _
bh NYc #+X " ^ N _
j NcN g "!Xk ^l#f!, cNf_##
NY g ##"^ N _
U NYc g ##"^ +" U#_
Uj Ncc !Xk ^l#f!, cNf_ +" U#
Vb
N
#"!+!!
Vb Nc
#"!+!! !
Vm Y m#!!
Page 19
1108 N Towner St &
#212/13/2024
Project:
Job No.:Job No.:
By:
Date:Date:
Page:Page:
Page 20
1108 N Towner St &
#212/13/2024
Fv 1.7 (Tbl 11.4-2)Seismic Category is D
SS 1.306 Roof Dead Load 15.0 PSF
SDS 1.045 (Eq 11.4-3)Floor Partition Load 8.0 PSF
SD1 0.527 (Eq 11.4-4)Total 23.0 PSF
S1 0.465 (Sec 11.4.2)
R Factor 6.5 (Tbl 12.2-1)Roof Height 15.0 ft (from 1st floor)
I 1 (Tbl 1.5-2)
ASD Factor 0.7
Redun. Factor 1.3 (Sec 12.3.4.2)
TL 8 (Fig 22-14)
Ct 0.020 (Tbl 12.8-2)
x 0.75 (Tbl 12.8-2)
T0 0.101 (Sec 11.4.6)
T 0.152 (Eq 12.8-7)Cross on Graph
Ts 0.504 (Sec 11.4.6)
Cs 0.161 (Eq 12.8-2)
Cs Limits 0.532 (Eq 12.8-3)
0.046 (Eq 12.8-5)
0.000 (Eq 12.8-6)
Cs 0.161 (Sec 12.8.1.1)
Final Cs 0.146 C s x Redun. Factor x ASD
Base Shear 3.36 PSF (ASD)
Wind Load 20.0 PSF (LRFD)
Trib. Height 4.5 ft
Bldg. "Depth"23.0 ft
ASD Factor 0.60
Wind Load 2.348 PSF (ASD)
Governing Load Seismic
3.36 PSF Shear Walls
3.36 PSF Diaphragm
15 ft
Diaphragm Aanlysis
Diaphragm Length (Short Side)23.00 ft
Diaphragm Width (Long Side)25.00 ft
Diaphragm Shear 42 plf
Allow. Shear (ASD)
15/32" STR-I plywood with 10d nails @ 6",12" unblocked 215 plf
15/32" STR-I plywood with 8d nails @ 6",12" unblocked 180 plf
15/32" plywood with 10d nails @ 6",12" unblocked 190 plf
15/32" plywood with 8d nails @ 6",12" unblocked 180 plf
Seismic Loading and Distribution per ASCE 7-16
0.00
0.20
0.40
0.60
0.80
1.00
1.20
0.00 0.50 1.00 1.50 2.00 2.50 3.00
Sp
e
c
t
r
a
l
A
c
c
e
l
e
r
a
t
i
o
n
(
g
)
Period (s)
Page 21
1108 N Towner St &
#212/13/2024
Wall and Seismic Information
QE (ASD)1050 lb E 1700000 psi Notes:
QE (LRFD)1500 lb Ga 16 kips/in Ga increased 20% per NDS (4 or 5 ply plywood)
Wall Height 8.00 ft Δa 0.125 in Deflections based on QE
Wall Length 4.00 ft A (post)12.25 in 2
Wall Weight 16 psf Drift Limit 0.020
r 1.33 Cd 4
Sds 1.045 Dead Loads 15 PSF Input
Cs (ASD)0.146 Live Loads 20 PSF Output
W 2.5 DL/LL Tributary 1.00 ft
Load Combinations with Seismic Load Effects ASCE 12.4.2 OTM RM T/C
(1.0 + 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 8 compression (ASD)8620 1311 2483
(1.0 + 0.10 SDs)D+0.525rQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)6465 1384 1962
(0.6 - 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 10 Tension (ASD)8620 519 -2025
Load Combinations with Seismic Load Effects and Overstrength Factor ASCE 12.4.3
(1.0 + 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 8 compression (ASD)16520 1311 4458
(1.0 + 0.105 SDs)D+0.525WQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)12390 1384 3443
(0.6 - 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 10 Tension (ASD)16520 519 -4000
NDS Tbl. 4.3.4 262.5
Ratio FLR/RF DL FLR/RF LL 4.3.3.4.1 (1) 4.3.4.2 Governs Shear Wall Deflection
2.00 15 20 N/A N/A N/A Term 1 0.0193 in
Term 2 0.1966 in
Forces with no Irregularity Term 3 0.2500 in
1050 lb Total 1.864 in (x C d )
Limit 1.9200 in
8 ft
4 ft Reduced
Tension Force = -2025 lb.HDU2 2306 1 86 N/A
Compression Force = 2483 lb.HDU4 3423 2 100 N/A
HDU5 4233 3 129 N/A
Forces with Horizontal Irregularity (Includes W)HDU8 4x 5227 4 260 N/A
1050 lb HDQ8 4x 5722 5 280 N/A
HDU8 6x 5902 6 286 N/A
HDU11 6x 7001 7 312 N/A
8 ft HDU14 6x6 10834 8 380 N/A
9 424 N/A
4 ft CMST14 4856 10 470 N/A
Tension Force = -4000 lb.CMST12 6911 11 489 N/A
Compression Force = 4458 lb.12 552 N/A
13 611 N/A
14 708 N/A
15 800 N/A
280.8
Holdown Values Shearwall Values
Shear Wall Calculation for Seismic Loads per SDPWS 2021
NORTH
Loads in (ASD)
PLF Loads at wall Reduced Shear Capacity
V (lb/ft) ASD
8ℎ
+
ℎ
1000
+
ℎ
∆
Page 22
1108 N Towner St &
#212/13/2024
Wall and Seismic Information
QE (ASD)1050 lb E 1700000 psi Notes:
QE (LRFD)1500 lb Ga 16 kips/in Ga increased 20% per NDS (4 or 5 ply plywood)
Wall Height 8.00 ft Δa 0.125 in Deflections based on QE
Wall Length 23.00 ft A (post)12.25 in 2
Wall Weight 16 psf Drift Limit 0.020
r 1.33 Cd 4
Sds 1.045 Dead Loads 15 PSF Input
Cs (ASD)0.146 Live Loads 20 PSF Output
W 2.5 DL/LL Tributary 4.00 ft
Load Combinations with Seismic Load Effects ASCE 12.4.2 OTM RM T/C
(1.0 + 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 8 compression (ASD)9664 57001 2898
(1.0 + 0.10 SDs)D+0.525rQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)7248 70792 3393
(0.6 - 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 10 Tension (ASD)9664 22561 561
Load Combinations with Seismic Load Effects and Overstrength Factor ASCE 12.4.3
(1.0 + 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 8 compression (ASD)19991 57001 3347
(1.0 + 0.105 SDs)D+0.525WQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)14993 70792 3730
(0.6 - 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 10 Tension (ASD)19991 22561 112
NDS Tbl. 4.3.4 45.6521739
Ratio FLR/RF DL FLR/RF LL 4.3.3.4.1 (1) 4.3.4.2 Governs Shear Wall Deflection
0.35 60 80 N/A N/A N/A Term 1 0.0008 in
Term 2 0.0448 in
Forces with no Irregularity Term 3 0.0435 in
1050 lb Total 0.356 in (x C d )
Limit 1.9200 in
8 ft
23 ft Reduced
Tension Force = 561 lb.HDU2 2306 1 86 N/A
Compression Force = 3393 lb.HDU4 3423 2 100 N/A
HDU5 4233 3 129 N/A
Forces with Horizontal Irregularity (Includes W)HDU8 4x 5227 4 260 N/A
1050 lb HDQ8 4x 5722 5 280 N/A
HDU8 6x 5902 6 286 N/A
HDU11 6x 7001 7 312 N/A
8 ft HDU14 6x6 10834 8 380 N/A
9 424 N/A
23 ft CMST14 4856 10 470 N/A
Tension Force = 112 lb.CMST12 6911 11 489 N/A
Compression Force = 3730 lb.12 552 N/A
13 611 N/A
14 708 N/A
15 800 N/A
64.0
Holdown Values Shearwall Values
Shear Wall Calculation for Seismic Loads per SDPWS 2021
SOUTH
Loads in (ASD)
PLF Loads at wall Reduced Shear Capacity
V (lb/ft) ASD
8ℎ
+
ℎ
1000
+
ℎ
∆
Page 23
1108 N Towner St &
#212/13/2024
Wall and Seismic Information
QE (ASD)1050 lb E 1700000 psi Notes:
QE (LRFD)1500 lb Ga 16 kips/in Ga increased 20% per NDS (4 or 5 ply plywood)
Wall Height 8.00 ft Δa 0.125 in Deflections based on QE
Wall Length 16.00 ft A (post)12.25 in 2
Wall Weight 16 psf Drift Limit 0.020
r 1.33 Cd 4
Sds 1.045 Dead Loads 15 PSF Input
Cs (ASD)0.146 Live Loads 20 PSF Output
W 2.5 DL/LL Tributary 4.00 ft
Load Combinations with Seismic Load Effects ASCE 12.4.2 OTM RM T/C
(1.0 + 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 8 compression (ASD)9279 27585 2304
(1.0 + 0.10 SDs)D+0.525rQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)6959 34259 2576
(0.6 - 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 10 Tension (ASD)9279 10918 102
Load Combinations with Seismic Load Effects and Overstrength Factor ASCE 12.4.3
(1.0 + 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 8 compression (ASD)18712 27585 2894
(1.0 + 0.105 SDs)D+0.525WQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)14034 34259 3018
(0.6 - 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 10 Tension (ASD)18712 10918 -487
NDS Tbl. 4.3.4 65.625
Ratio FLR/RF DL FLR/RF LL 4.3.3.4.1 (1) 4.3.4.2 Governs Shear Wall Deflection
0.50 60 80 N/A N/A N/A Term 1 0.0014 in
Term 2 0.0588 in
Forces with no Irregularity Term 3 0.0625 in
1050 lb Total 0.491 in (x C d )
Limit 1.9200 in
8 ft
16 ft Reduced
Tension Force = 102 lb.HDU2 2306 1 86 N/A
Compression Force = 2576 lb.HDU4 3423 2 100 N/A
HDU5 4233 3 129 N/A
Forces with Horizontal Irregularity (Includes W)HDU8 4x 5227 4 260 N/A
1050 lb HDQ8 4x 5722 5 280 N/A
HDU8 6x 5902 6 286 N/A
HDU11 6x 7001 7 312 N/A
8 ft HDU14 6x6 10834 8 380 N/A
9 424 N/A
16 ft CMST14 4856 10 470 N/A
Tension Force = -487 lb.CMST12 6911 11 489 N/A
Compression Force = 3018 lb.12 552 N/A
13 611 N/A
14 708 N/A
15 800 N/A
83.9
Holdown Values Shearwall Values
Shear Wall Calculation for Seismic Loads per SDPWS 2021
EAST
Loads in (ASD)
PLF Loads at wall Reduced Shear Capacity
V (lb/ft) ASD
8ℎ
+
ℎ
1000
+
ℎ
∆
Page 24
1108 N Towner St &
#212/13/2024
Wall and Seismic Information
QE (ASD)1050 lb E 1700000 psi Notes:
QE (LRFD)1500 lb Ga 16 kips/in Ga increased 20% per NDS (4 or 5 ply plywood)
Wall Height 8.00 ft Δa 0.125 in Deflections based on QE
Wall Length 11.00 ft A (post)12.25 in 2
Wall Weight 16 psf Drift Limit 0.020
r 1.33 Cd 4
Sds 1.045 Dead Loads 15 PSF Input
Cs (ASD)0.146 Live Loads 20 PSF Output
W 2.5 DL/LL Tributary 4.00 ft
Load Combinations with Seismic Load Effects ASCE 12.4.2 OTM RM T/C
(1.0 + 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 8 compression (ASD)9004 13038 2004
(1.0 + 0.10 SDs)D+0.525rQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)6753 16193 2086
(0.6 - 0.14 SDs)D+0.7rQE ASCE 2.4.5 eq. 10 Tension (ASD)9004 5160 -349
Load Combinations with Seismic Load Effects and Overstrength Factor ASCE 12.4.3
(1.0 + 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 8 compression (ASD)17799 13038 2803
(1.0 + 0.105 SDs)D+0.525WQE+0.75L+0.75Lr ASCE 2.4.5 eq. 9 compression (ASD)13349 16193 2686
(0.6 - 0.14 SDs)D+0.7WQE ASCE 2.4.5 eq. 10 Tension (ASD)17799 5160 -1149
NDS Tbl. 4.3.4 95.4545455
Ratio FLR/RF DL FLR/RF LL 4.3.3.4.1 (1) 4.3.4.2 Governs Shear Wall Deflection
0.73 60 80 N/A N/A N/A Term 1 0.0028 in
Term 2 0.0796 in
Forces with no Irregularity Term 3 0.0909 in
1050 lb Total 0.694 in (x C d )
Limit 1.9200 in
8 ft
11 ft Reduced
Tension Force = -349 lb.HDU2 2306 1 86 N/A
Compression Force = 2086 lb.HDU4 3423 2 100 N/A
HDU5 4233 3 129 N/A
Forces with Horizontal Irregularity (Includes W)HDU8 4x 5227 4 260 N/A
1050 lb HDQ8 4x 5722 5 280 N/A
HDU8 6x 5902 6 286 N/A
HDU11 6x 7001 7 312 N/A
8 ft HDU14 6x6 10834 8 380 N/A
9 424 N/A
11 ft CMST14 4856 10 470 N/A
Tension Force = -1149 lb.CMST12 6911 11 489 N/A
Compression Force = 2803 lb.12 552 N/A
13 611 N/A
14 708 N/A
15 800 N/A
113.8
Holdown Values Shearwall Values
Shear Wall Calculation for Seismic Loads per SDPWS 2021
WEST
Loads in (ASD)
PLF Loads at wall Reduced Shear Capacity
V (lb/ft) ASD
8ℎ
+
ℎ
1000
+
ℎ
∆
Page 25
1108 N Towner St &
#212/13/2024
SANTA ANA CITY COUNCIL
Mayor
vamezcua@santa-ana.org
Mayor Pro Tem, Ward 1
tphan@santa-ana.org
Ward 2
bvazquez@santa-ana.org
Ward 3
jessielopez@santa-ana.org
Ward 4
pbacerra@santa-ana.org
Ward 5
jryanhernandez@santa-ana.org
Ward 6
dpenaloza@santa-ana.org
MAYOR
Valerie Amezcua
MAYOR PRO TEM
Thai Viet Phan
COUNCILMEMBERS
Phil Bacerra
Johnathan Ryan Hernandez
Jessie Lopez
David Penaloza
Benjamin Vazquez
CITY OF SANTA ANA
PLANNING AND BUILDING AGENCY
20 Civic Center Plaza ● P.O. Box 1988
Santa Ana, California 92702
www.santa-ana.org
INTERIM CITY MANAGER
Alvaro Nuñez
CITY ATTORNEY
Sonia R. Carvalho
CITY CLERK
Jennifer L. Hall
July 1, 2024
Also sent via email to: eduardo@avdesign.la
Lubna Debbini
1108 North Towner Street
Santa Ana, CA 92703
Subject: Address Assignment for a Detached Accessory Dwelling Unit located at 1108
North Towner Street (APN: 405-292-05) in Santa Ana, CA
Dear Lubna,
The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal
addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment
for a 547-square-foot garage-conversion ADU located at 1108 North Towner Street (APN: 405-
292-05). Notice is hereby given that the following assigned address shall be posted onsite per the
approved address plan, attached hereto as Exhibit A.
Address to be Activated/Posted
1108
To subdivide commercial and/or residential units into multiple units, a building permit (and all other
associated permits), plans, and inspection approvals by the PBA are required. The address will
be verified during inspections by the Building Safety Division.
Please update your records accordingly. Should you have any questions, feel free to contact me
by phone at (714) 664-2753 or by email at PRaj@santa-ana.org.
Sincerely,
Punkaj Raj
Planning Technician
Exhibit A – Address Plan
1108 N Towner St &
#212/13/2024
Address Letter for 1108 North Towner Street
Page 2 of 2
c:
Vencent Quaglia, United States Post Office
Chris Tuiolosega, United States Post Office
Cipriano Corona, Marketing Manager, United States Post Office
Alex Alvarez, Postmaster Santa Ana, United States Post Office
Federal Express, Administration
Cathy Joseph, Garden Grove Unified School District
Christine Hy, Garden Grove Unified School District
Cathy Slader, Orange Unified School District
Orin Williams, Santa Ana Unified School District
Yvette Miranda, Santa Ana Unified School District
Cristina Bernal, Tustin Unified School District
Mishele Richards, Orange County Fire Authority, GEO Files Coordinator
Orange County Fire Authority
Neal Kelly, Registrar of Voters
Members, Board of Supervisors
Southern California Gas Company
Southern California Edison Company
Claude Parrish, County Assessor's Office
SAG, AT&T
UPS, Administration
City Manager’s Office
Beverly Martin, Police Community Services Specialist
Boris Duran, Police Systems Manager
Jennifer Mendoza, Police Communications Manager
Chris Hubbard, Police Systems Support Analyst
Alejandra Gutierrez, Treasury & Customer Services Manager
Hector Jimenez, Revenue Supervisor
Alfonso Chavez, Utilities Customer Services Supervisor
Judson Brown, Housing & Neighborhood Development Manager
Rudy Rosas, Principal Civil Engineer
Zdenek (Zed) Kekula, Principal Civil Engineer
Jason Kwak, Building Safety Manager
Evelyn LaRocca, Permit Supervisor
Kathy Hernandez, Permit Technician
Julie Amsden, Permit Technician
Ali Pezeshkpour, Planning Manager
Jerry Guevara, Senior Planner
Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager
1108 N Towner St &
#212/13/2024
(N) ADU1108 N. TOWNER STREET, UNIT 2
(E) SINGLE-FAMILY DWELLING1108 N. TOWNER STREET
EXHIBIT A: ADDRESS PLAN
1108 N Towner St &
#212/13/2024
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Submittal Criteria Form
Required for Single Family or Duplex Residences
(Use Commercial form for lots with 3+ dwelling units or new residential tracts)
Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification.
Project Information
New Single Family Residence/Duplex Addition/Remodel ADU Other
Address: Unit #: City or Unincorporated County Area: ZIP:
Scope of Work:
Existing Area to Total Resulting Stories: Area Added in Past 2 Years
Yes No Questionnaire OCFA Plan Type if “Yes”
1. New – Is this a new single family residence or duplex? *(PR160) Residential Site
with Water Availability
2. ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler
Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire
sprinkler retrofit based on a threshold set by local ordinance?
(PR400-402) Fire Sprinkler
4. Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site
5. Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non-
sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all
*(PR160) Residential Site
with Water Availability
6. Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or
removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed
(PR400-402) Fire Sprinkler
Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a
garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold
*(PR160) Residential Site
(PR400-402) Fire Sprinkler
8. Gate – Is a gate being installed across a driveway or road that is designated as a fire department
access roadway, or a driveway or road that serves more than a single home/duplex?
(PR180) Gate
9. Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal
Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas
seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only
applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000
*(PR160) Residential Site
*(PR172-174) Methane
Test/Mitigation Plans
10. Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to
slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation,
or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as
*(PR125) Fuel Modification
(PR182) Accessory
Structure
*OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals.
Applicant Certification
I certify, under penalty of perjury, under the laws of the State of California, that the information above is true:
Print Name:_______________________________________ Signature:___________________________________________ Date:______________
Phone Number:_____________________________________________ Email:_____________________________________________________________
Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a
written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required.
______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes”
and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral
Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination.
For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100
SFR
1108 N Towner St &
#212/13/2024
1108 N Towner St &
#212/13/2024