Loading...
HomeMy WebLinkAbout4021 W Mary Cir - PlanSCOPE OF WORK: INSTALL (18) APTOS DNA-120-BF10-440W SOLAR ELECTRIC MODULES AND (18) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY TAR & GRAVEL ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) LG CHEM RESU 16H PRIME BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. HOMEOWNER: LESLIE YAM PH: 714.856.1988 ADDRESS: 4021 MARY CIRCLE SANTA ANA, CA 92703 DATE: 7/30/24 ING ELECTRIC INC 1451 DOMIGUEZ RANCH ROAD CORONA, CA 92882 PH: 951.399.2555 NORAN ING C10 - 1048140 VICINITY MAP YAM RESIDENCE SHEET INDEX: SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK SHEET 2 SITE/ROOF PLAN SHEET 3 ELEVATION DETAIL, WALL ELEVATION DETAIL SHEET 4 ELECTRIC LINE DRAWING, GROUNDING DETAIL SHEET 5 SIGNS SHEET 6 CALCULATIONS ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, STRUCTURAL REPORT NTS SHEET NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. 1 OF 6 PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 (18) APTOS DNA-120-BF10-440W PEAK POWER = 440 W MAX OPERATING CURRENT = 12.68 A MAX OPERATING VOLTAGE = 34.71 V OPEN CIRCUIT VOLTAGE = 41.51 V SHORT CIRCUIT CURRENT = 12.88 A MAX SERIES FUSE RATING = 30 A TEMP. COEFF. OF Voc = -0.27%/°C DIMENSIONS = 75.1" X 44.6" X 1.3" WEIGHT = 50.2 LBS GENERAL NOTES: 1. THIS SYSTEM COMPLIES WITH THE 2022 CRC, 2022 CBC, 2022 CFC, AND THE 2022 CEC. 2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY HAS BEEN NOTIFIED. 3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. 4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. 5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE UL 1741 COMPLIANT. 6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER. 7. CONDUCTORS ARE 90° C RATED COPPER WIRE. 8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED IN A METAL RACEWAY. 10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE PROTECTED IN CONDUIT. 11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES AND RAILS AND SECURED IN PLACE. 12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. 17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS. 70402PV5 INVERTER/DC DISCONNECT: (1) SOLAREDGE ENERGY HUB SE7600H-US MAX DC INPUT VOLTAGE = 480 V NOMINAL DC INPUT VOLTAGE = 400 V MAX DC INPUT CURRENT = 20.0 A DC DISCONNECT MAX INPUT CURRENT = 45.0 A NUMBER OF DC INPUTS = 2 RATED AC POWER = 7600 W AC VOLTAGE = 240 V MAX AC OUTPUT CURRENT = 32.0 A NEMA 4X ENCLOSURE DIMENSIONS = 17.7" X 14.6" X 6.8" WEIGHT = 26 LBS PHOTOVOLTAIC SOLAR PROJECT INFORMATION: SYSTEM SIZE: 7.920 kW (DC), 7.260 kW (AC) MODULES: MODULE ADD-ON:(18) SOLAREDGE S440 DC POWER OPTIMIZERS MAX DC INPUT VOLTAGE = 60 V OPERATING VOLTAGE RANGE = 8 V - 60 V MAX DC INPUT CURRENT = 14.5 A MAX DC OUTPUT CURRENT = 15 A DC OUTPUT VOLTAGE = 380 V MAX POWER PER STRING (CONTROLLED BY INVERTER) = 5700 W NEMA 6P ENCLOSURE DIMENSIONS = 5.1" X 6.1" X 1.2" WEIGHT = 1.6 LB ARRAY:INSTALLED WEIGHT = 2.9 PSF ROOF COVERAGE = 420 SF, ARRAYS COVER 18% OF TOTAL ROOF AREA MOUNTING HARDWARE: K2 CROSSRAIL 48XL RAIL K2 SPLICE FOOT WITH K2 EVERSEAL ATTACHMENTS 5 16" STAINLESS STEEL LAG BOLTS @ 64" OC OR LESS WITH A MINIMUM OF 212" PENETRATION INTO ROOF RAFTERS EXISTING ROOF INFO: 1 STORY, TAR & GRAVEL 4 X 6 RAFTERS @ 32" OC BATTERY: (1) LG CHEM RESU 16H PRIME USABLE ENERGY = 16 kWh PEAK POWER = 11 kW FOR 10SEC. PEAK CURRENT = 32.8 A FOR 10SEC. MAX POWER = 7.0 kW IP55 ENCLOSURE DIMENSIONS = 19.8" X 42.8" X 11.6" WEIGHT = 350 LBS JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101120659 Elec# 20183864 Approvals: Elec. MSmith 4021 W Mary Cir 9/12/2024 SCOPE OF WORK: INSTALL (18) APTOS DNA-120-BF10-440W SOLAR ELECTRIC MODULES AND (18) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY TAR & GRAVEL ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) LG CHEM RESU 16H PRIME BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. HOMEOWNER: LESLIE YAM PH: 714.856.1988 ADDRESS: 4021 MARY CIRCLE SANTA ANA, CA 92703 DATE: 7/30/24 ING ELECTRIC INC 1451 DOMIGUEZ RANCH ROAD CORONA, CA 92882 PH: 951.399.2555 NORAN ING C10 - 1048140 NOTE: DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO SCALE BUT WERE TAKEN FROM A FIELD SURVEY AND APPROXIMATIONS MADE USING GOOGLE EARTH. (E) 200 AMP MAIN SERVICE PANEL MARY C I R C L E N SCALE: 1/16"=1' 8 16 32 48 CHIMNEY SITE/ROOF PLAN PROPERTY LINE SHEET NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. 2 OF 6 PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 1.5' FIRE CLEARANCE 70402PV5 ROOF ACCESS POINTS ARE AT THE STRUCTURALLY STRONG PART OF THE BUILDING AND DO NOT REQUIRE LADDERING OVER OPENINGS. * TOTAL ROOF AREA = 2352 SF TOTAL SOLAR AREA = 420 SF 420 SF/2352 SF = 0.18 ARRAYS COVER 18% OF TOTAL ROOF AREA ARRAY #1: (6) MODULES TILT = 9°, AZ = 316° ARRAY #2: (12) MODULES TILT = 9°, AZ = 136° VENT (TYP) * * 13 14 11 12 1 2 3 4 5 6 PROPERTY LINE (N) INVERTER/DC DISCONNECT, (N) BATTERY & (N) AC DISCONNECT 15 16 9 10 17 18 7 8 (E) DETACHED PATIO COVER PROPERTY LINE PROPERTY LINE (E) SHED 5'-3" 25'-5" 11'-6" 39'-6" (E) DETACHED PATIO COVER 1'-6" 3' (E) HOUSE JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 SCOPE OF WORK: INSTALL (18) APTOS DNA-120-BF10-440W SOLAR ELECTRIC MODULES AND (18) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY TAR & GRAVEL ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) LG CHEM RESU 16H PRIME BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. HOMEOWNER: LESLIE YAM PH: 714.856.1988 ADDRESS: 4021 MARY CIRCLE SANTA ANA, CA 92703 DATE: 7/30/24 ING ELECTRIC INC 1451 DOMIGUEZ RANCH ROAD CORONA, CA 92882 PH: 951.399.2555 NORAN ING C10 - 1048140 SHEET NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. 3 OF 6 PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 70402PV5 EXISTING 1-STORY ROOF: TAR & GRAVEL, FELT & 1 2" SHEATHING OVER RAFTERS EXISTING 4 X 6 RAFTERS @ 32" OC MODULES: 75.1" X 44.6" 50.2 LBS EACH K2 CROSSRAIL 48XL RAIL MOUNTING SYSTEM WITH K2 SPLICE FOOT WITH K2 EVERSEAL ATTACHMENTS (USE 5 16" STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM EMBEDMENT OF 21 2" INTO ROOF RAFTERS), WATERPROOF ALL CONNECTION LOCATIONS PER MANUFACTURER'S INSTRUCTIONS 3" MIN. 8" MAX. NTS ELEVATION DETAIL WALL ELEVATION DETAIL SCALE: 1/4" = 1'-0" (N) INVERTER/ DC DISCONNECT WA L L C O R N E R GROUND LEVEL (N) AC DISCONNECT (N) BATTERY 1'-1" JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 This Spec added for additional information. MAS(19) 4021 W Mary Cir 9/12/2024 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 4021 W Mary Cir 9/12/2024 4021 W Mary Cir 9/12/2024 4021 W Mary Cir 9/12/2024 SCOPE OF WORK: INSTALL (18) APTOS DNA-120-BF10-440W SOLAR ELECTRIC MODULES AND (18) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY TAR & GRAVEL ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) LG CHEM RESU 16H PRIME BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. HOMEOWNER: LESLIE YAM PH: 714.856.1988 ADDRESS: 4021 MARY CIRCLE SANTA ANA, CA 92703 DATE: 7/30/24 ING ELECTRIC INC 1451 DOMIGUEZ RANCH ROAD CORONA, CA 92882 PH: 951.399.2555 NORAN ING C10 - 1048140 ELECTRICAL LINE DIAGRAM SHEET NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. 4 OF 6 PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 MAIN SERVICE INFO: 200 A, 120/240 VAC, 1Ø, 3-WIRE 40A 200A EXISTING BUILDING GROUNDING ELECTRODE SYSTEM M EXISTING SERVICE PANEL: 200 A BUS RATED, 240 VAC, 1Ø G L1 L2 60 A, 240 VAC, 1Ø AC DISCONNECT LOCKABLE, VISIBLE KNIFE-BLADE TYPE (3) 8 AWG THWN-2 & (1) 8 AWG GROUND IN 3 4" EMT CONDUIT (3) 8 AWG THWN-2 & (1) 8 AWG GROUND IN 3 4" EMT CONDUIT L1 L2 N G SOLAREDGE INTEGRATED DC DISCONNECT, AC DISCONNECT & RAPID SHUTDOWN DEVICE SOLAREDGE ENERGY HUB SE7600H-US 240 VAC, 1Ø TRANSFORMERLESS INVERTER - + PV BAT NC NC NONO L1 L2 NOTE TO INSTALLERS: PLEASE SEE THE INSTALLATION MANUAL FOR PROPER CT INSTALLATION (THEY ARE DIRECTIONAL) FOR MONITORING AND OPERATION. APTOS DNA-120-BF10-440W + - + - SOURCE CIRCUIT #1: 9 MODULES, 600 VDC + - + - (4) 10 AWG PV IN AIR (9) 600 VDC SOLAREDGE S440 OPTIMIZERS + - + - + - + - SOURCE CIRCUIT #2: 9 MODULES, 600 VDC + - + - + - + - (9) 600 VDC SOLAREDGE S440 OPTIMIZERS NEMA 3R, 600 VDC JUNCTION BOX (4) 10 AWG THWN-2 & (1) 8 AWG GROUND IN 3 4" EMT CONDUIT USE K2 INTEGRATED GROUNDING TO GROUND ALL MODULES, OPTIMIZERS, JUNCTION BOXES AND ANY OTHER METAL PARTS AND #6 AWG SOLID COPPER WHERE NECESSARY 70402PV5 APTOS DNA-120-BF10-440W APTOS DNA-120-BF10-440W APTOS DNA-120-BF10-440W APTOS DNA-120-BF10-440W APTOS DNA-120-BF10-440W -+ LG CHEM RESU 16H PRIME 400V BATTERY G BI-DIRECTIONAL POWER FLOW (2) 8 AWG THWN-2 & (1) 8 AWG GROUND IN 3 4" EMT CONDUIT JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL PLAN CHECK NOTE: The main service panel is being replaced under Permit #2018-3618. Service panel must be approved prior to this PV permit approval. MAS(19) 4021 W Mary Cir 9/12/2024 SCOPE OF WORK: INSTALL (18) APTOS DNA-120-BF10-440W SOLAR ELECTRIC MODULES AND (18) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY TAR & GRAVEL ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) LG CHEM RESU 16H PRIME BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. HOMEOWNER: LESLIE YAM PH: 714.856.1988 ADDRESS: 4021 MARY CIRCLE SANTA ANA, CA 92703 DATE: 7/30/24 ING ELECTRIC INC 1451 DOMIGUEZ RANCH ROAD CORONA, CA 92882 PH: 951.399.2555 NORAN ING C10 - 1048140 SYSTEM SIGNAGESYSTEM SIGNAGE ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH WEATHERPROOF ADHESIVE OR OTHER APPROVED METHOD. ALL LETTERS SHALL BE A MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH "WARNING: PHOTOVOLTAIC POWER SOURCE". WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT ALL SERVICEABLE PANELS OR BOXES AND AT ALL DISCONNECTS: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED MAY BE ENERGIZED SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION CAUTION: MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN. ADDRESS: 4021 MARY CIRCLE, SANTA ANA, CA 92703 SOLAR ARRAY (ON ROOF) N INVERTER & DC DISCONNECT TO BE INSTALLED ON THE OUTSIDE COVER OF THE MAIN SERVICE DISCONNECT: PV SOLAR DC DISCONNECT MAXIMUM VOLTAGE = 480.00 V MAXIMUM CIRCUIT CURRENT = 30.00 A MAXIMUM RATED OUTPUT CURRENT OF THE DC-TO-DC CONVERTER = 15.00 A TO BE INSTALLED ON THE FRONT OF THE DC DISCONNECT: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM AC OUTPUT CURRENT = 32.00 A NOMINAL OPERATING AC VOLTAGE = 240 V TO BE INSTALLED ON THE FRONT OF THE AC DISCONNECT: WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE TO BE INSTALLED AT THE BACKFED BREAKER SERVING THE PV SOLAR SYSTEM: TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TO BE INSTALLED ON THE FRONT OF THE MAIN SERVICE DISCONNECT: "SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN" SHALL BE BLACK LETTERING ON YELLOW BACKGROUND. THE REMAINDER OF THE SIGN SHALL BE BLACK LETTERING ON WHITE BACKGROUND. SHEET NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. 5 OF 6 PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 70402PV5 WARNING ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED DO NOT OPERATE CONTROLS OR OPEN COVERS WITHOUT APPROPRIATE PERSONAL PROTECTION EQUIPMENT. FAILURE TO COMPLY MAY RESULT IN INJURY OR DEATH! REFER TO NFPA 70E FOR MINIMUM PPE REQUIREMENTS TO BE INSTALLED ON THE FRONT OF THE BATTERY: ENERGY STORAGE SYSTEM DISCONNECT TO BE INSTALLED ON THE FRONT OF THE INVERTER: BATTERY JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 SCOPE OF WORK: INSTALL (18) APTOS DNA-120-BF10-440W SOLAR ELECTRIC MODULES AND (18) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY TAR & GRAVEL ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) LG CHEM RESU 16H PRIME BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. HOMEOWNER: LESLIE YAM PH: 714.856.1988 ADDRESS: 4021 MARY CIRCLE SANTA ANA, CA 92703 DATE: 7/30/24 ING ELECTRIC INC 1451 DOMIGUEZ RANCH ROAD CORONA, CA 92882 PH: 951.399.2555 NORAN ING C10 - 1048140 SHEET NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. 6 OF 6 PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 SYSTEM CALCULATIONS: MODULE POWER = 440 W NUMBER OF MODULES IN LONGEST STRING = 9 (9) 440 W = 3960 W OPTIMIZER MAX POWER PER STRING = 6000 W 3960 W < 6000 W, OK OPERATING CURRENT = POWER RATING/OPERATING VOLTAGE = 3960 W/400 V = 9.90 A OPTIMIZER TO INVERTER TARGET VOLTAGE/OPERATING VOLTAGE = 400 V MAX SYSTEM VOLTAGE (Voc) CONTROLLED BY INVERTER = 480 V SHORT-CIRCUIT CURRENT (Isc) CONTROLLED BY OPTIMIZER = 15.00 A INVERTER MAX OUTPUT CURRENT = 32.00 A 32.00 A (1.25) = 40.00 A [Ic], USE 40 A BREAKER MAIN SERVICE PANEL BUS RATING = 200 A MAIN SERVICE PANEL MAIN OCPD = 200 A 200 A + 40 A SOLAR OCPD = 240 A 200 A BUS (1.2) = 240 A 240 A = 240 A, OK WIRE CALCULATIONS: FROM OPTIMIZERS TO INVERTER/DC DISCONNECT: AMBIENT TEMPERATURE = 34°C TEMPERATURE ADDER FOR CONDUIT NOT OFFSET FROM ROOF = 33°C ADJUSTMENT FACTOR PER TABLE 310.15(B)(1) FOR 90°C INSULATED CONDUCTOR AT 34°C + 33°C = 67°C = 0.58 Isc = 15.00 A 15.00 A/0.58 = 25.86 A NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 4 ADJUSTMENT FACTOR PER TABLE 310.15(C)(1) FOR CONDUIT FILL (4-6 CONDUCTORS IN CONDUIT) = 0.80 25.86 A/0.80 = 32.33 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 32.33 A, USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 40 A SELECT CONDUIT FOR (4) 10 AWG THWN-2 & (1) 8 AWG GROUND = 3 4" EMT CONDUIT FROM THE INVERTER TO THE MAIN SERVICE PANEL: ADJUSTMENT FACTOR PER TABLE 310.15(B)(1) FOR 90°C INSULATED CONDUCTOR AT 34°C = 0.96 Ic = 40.00 A 40.00 A/0.96 = 41.67 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 41.67 A, USE 8 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 55 A SELECT CONDUIT FOR (3) 8 AWG THWN-2 & (1) 8 AWG GROUND = 3 4" EMT CONDUIT 70402PV5 JENNIFER KEMME No: 73054 Exp: 12/31/24 CIVIL 4021 W Mary Cir 9/12/2024 4021 W Mary Cir 9/12/2024 4021 W Mary Cir 9/12/2024 STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROMHIS SITE INSPECTION. 1 Project Information:PV SOLAR ARRAY: YAM RESIDENCELatitude33.7551°deg N 4021 MARY CIRCLE, SANTA ANA, CA 92703Longitude-117.924°deg WWind Speed 110 mph 95 mph (ASCE 7-22)Wind Exposure CSite Class DSeismic Design Category D 2 Loads: Existing Roof Dead Loads:4 x 6 Beams @ 32" OC 1.7 psf1/2" Roof Sheathing 1.7 psfRoof Felt 1.5 psfTar & Gravel 8.0 psfMiscellaneous3.1 psfTotal16.0 psf Existing Snow Load:0.0 psfExisting Roof Live Load:20.0 psfProposed Roof Live Load: 20.0 psf Wind Load: Using CBC 2022 (ASCE 7-22), Chapter 29: Wind Loads on Rooftop Equipment, the following wind pressures were calculated.p = qh (GCp) (ge) (ga) = 7.84 -40.34 psfqh = 0.00256 Kz Kzt Kd Ke V2 =21.76 psfKz = 0.85 (0-15 = 0.85, 20 = 0.90, 25 = 0.94, 30 = 0.98, 40 = 1.04)GCp =0.7 -3.6 (Roof pitch = 9 deg, Zone = 2, Aeff = 23.3 sf) ge = 1.50 ga = 0.80 Lag Bolt Capacity:5/16" lag bolt capacity = 270 lbs per inch embedmentWith 2 1/2" minimum embedment, capacity = 675 lbsRequired Capacity:40.34 psf *18 modules *23.3 sf =16920.6 lbs16920.6 lbs /30 lag bolt connections = 564.0 lbsThe pull-out capacity of the 5/16" lag bolts with a minimum 2 1/2" embedment into the roof rafter is sufficientto meet the demand of the wind uplift force on the solar system. Seismic Load: Per the CEBC 2022 Section 503.4, if the demand-capacity ratio of the lateral load-carrying elements increases less than 10% due to the addition of the solar system, no special provisions or structuralmodifications are required.Existing Roof Weight = 16.0 psf *2352 sf =37632 lbsWeight of Solar System = 18 modules *51.8 lbs +210 lbs of racking = 1142 lbs1142lbs / 37632 lbs =0.03The increase in load from the solar system will not increase the demand-capacity ratio of the existing lateralload-carrying elements by over 10%. NOTICE: VISION CIVIL ENGINEERING: JENNIFER KEMME, PEANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300,JENKEMME@VISIONCE.COMCIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/24 Prepared by JENNIFER KEMME 7/31/2024 Page 1 4021 W Mary Cir 9/12/2024 STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROMHIS SITE INSPECTION. 3 Analysis of Existing Rafter Capacity:PV SOLAR ARRAY: YAM RESIDENCE4021 MARY CIRCLE, SANTA ANA, CA 92703 Rafter Loads:Solar system dead load = 1142 lbs /30 lag bolts total =38.1 lbs at each lag boltExisting roof dead load =16 psfSnow load = 0 psfRoof live load =20 psfWind load = 109.7 lbs,564.0 lbsRafter span =15.0 ft Load Combinations That Apply:#1: D + Lr or S = 16 psf +38.1 lbs at each lag bolt +20.0 psf#2: D + 0.75(0.6W) + 0.75(Lr or S) = (16 psf +38.1 lbs at each lag bolt) + (0.75 (0.6)109.7 lbs at each lag bolt) + (0.75 (20 psf))#3: 0.6D + 0.6W = 0.6 (16 psf + 38.1 lbs at each lag bolt) - (0.6)564.0 lbs at each lag bolt Calculated Maximum Bending Moment:#1:1012.5 ft/lbs +142.8 ft/lbs = 1155.3 ft/lbs[(36 psf) (15 ft^2)] / 8 = 1012.5 ft/lbs[(38.07 lbs) (15.0 ft)] / 4 =142.76 ft/lbs#2:450.0 ft/lbs +142.8 ft/lbs +185.1 ft/lbs +421.9 ft/lbs =1199.7 ft/lbs[(16 psf) (15 ft^2)] / 8 = 450.0 ft/lbs[(38.07 lbs) (15.0 ft)] / 4 =142.76 ft/lbs109.7 lbs) (15 ft)] / 4 = 185.1 ft/lbs0.75 [(20 psf) (15 ft^2)] / 8 = 421.9 ft/lbs#3:270.0 ft/lbs +85.7 ft/lbs -1269.0 ft/lbs =-913.4 ft/lbs0.6 [(16 psf) (15 ft^2)] / 8 = 270.0 ft/lbs0.6 [(38.07 lbs) (15.0 ft)] / 4 =85.658 ft/lbs0.6 [(564.0 lbs) (15 ft)] / 4 =1269.0 ft/lbs Section Required:1199.7 ft/lbs (12) (0.7) / 1518 psi = 6.6 cu inSection Provided:3.5 (5.5 ^2) / 6 =17.6 cu in17.6 cu in >6.6 cu in, OK Calculated Deflection:[5(36 psf / 12) (180 in^4)] / [384 (1200000) (48.5 )] =0.70 inAllowable Deflection:180 in / 240 = 0.75 in0.75 in >0.70 in, OK NOTICE: VISION CIVIL ENGINEERING: JENNIFER KEMME, PEANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300,JENKEMME@VISIONCE.COMCIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/24 0.75 [(0.6)( Prepared by JENNIFER KEMME 7/31/2024 Page 2 4021 W Mary Cir 9/12/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 4021 W Mary Cir 9/12/2024