Loading...
HomeMy WebLinkAbout3050 S Bradford Pl Unit# G - PlanPROJECT INFORMATION PROPERTY OWNER NAME:PEDRO ALCANTRA PHONE:- CONTRACTOR NAME:ILUM SOLAR PHONE:1-888-696-4586 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: B WIND SPEED: 95 MPH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (ENERGY) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2020 NATIONAL ELECTRICAL CODE (NEC) 2022 CALIFORNIA FIRE CODE (CFC) SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ T-1 TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE SSP SCOPE OF WORK SYSTEM SIZE: STC: 15 X 400W = 6.000kW PTC: 15 X 376.7W = 5.651kW (15) CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES (15) ENPHASE IQ8PLUS-72-2-US [240V] MICROINVERTERS (1) 125A ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C) BOX (2) ENPHASE IQ BATTERY 5P (IQ BATTERY-5P-1P-NA) [240V] (1) 60A KNIFE AC DISCONNECT (SQUARE D DU222RB) (1) 100A KNIFE AC DISCONNECT (SQUARE D DTU223RB) (1) 200A SUB SERVICE PANEL MSP UPGRADE: NO MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: UNIRAC FLASHLOC RM FOR EPDM FLAT ROOF ROOF RACKING TYPE: UNIRAC SM- ROOF MOUNT RACKING HARDWARE ALCANTRA RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 6.000 kW COORDINATES: 33.707830, -117.875453 AERIAL VIEW SHEET # T-1 T-2 PV-1 PV-2 PV-3 E-1, E-2 E-3 S-1 S-2 S-3 S-4 S-5 S-6 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET S-7 SPEC SHEET S-8 SPEC SHEET E-4 ELEVATION SHEET S-9 S-10 S-11 SPEC SHEET SPEC SHEET SPEC SHEET S-12 SPEC SHEET S-13 SPEC SHEET Signed 6/13/2024 Structural Only ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. *** Bldg#: 101119758 Elec#: 20183184 Approvals: Elec: MSmith 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 1.1.PROJECT NOTES: 1.2. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.5(A) 1.5. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.9.SCOPE OF WORK: 1.10. PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11.WORK INCLUDES: 1.12. PV ROOF ATTACHMENTS - UNIRAC FLASHLOC RM FOR EPDM FLAT ROOF ROOF 1.13. PV RACKING SYSTEM INSTALLATION - UNIRAC SM ROOF MOUNT RACKING HARDWARE 1.14. PV MODULE AND INVERTER INSTALLATION - CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES / ENPHASE IQ8PLUS-72-2-US [240V] MICROINVERTERS 1.15. PV EQUIPMENT GROUNDING 1.16. PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17. PV LOAD CENTERS (IF INCLUDED) 1.18. PV METERING/MONITORING (IF INCLUDED) 1.19. PV DISCONNECTS 1.20. PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21. PV FINAL COMMISSIONING 1.22. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23. SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24.SITE NOTES: 1.25. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. 1.27. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 1.29. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE.SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ T-2 1.56. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [2022 CEC 250.119] 1.59. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. 1.60. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41 IN GENERAL AND CEC 690.41 (A)(1) SPECIFICALLY. 1.61.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 1 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC 690.12(B)]. LOCATION OF LABEL ACCORDING TO AHJ 1.65. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. 1.66. EQUIPMENT THAT IS LISTED, LABELED, OR BOTH SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING. CEC 110.3(B). 1.67. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. 1.68.ELECTRICAL INTERCONNECTION NOTES: 1.69. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF THE BUSBAR RATING. 1.70. WHEN THE SUM OF THE PV SOURCES EQUALS >100% OF THE BUSBAR RATING, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD. 1.71. AT MULTIPLE PV OUTPUT COMBINER PANEL, THE TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED. 1.72. SUPPLY-SIDE TAP INTERCONNECTION SHOULD BE WITH SERVICE ENTRANCE CONDUCTORS. 1.73. BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING. 1.30.EQUIPMENT LOCATIONS: 1.31. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2022 CEC 110.26. 1.32. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2022 CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO 2022 CEC 690.34. 1.34. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT . 1.35. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2022 CEC APPLICABLE CODES. 1.36. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37.STRUCTURAL NOTES: 1.38. RACKING SYSTEM 1.39. PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45.WIRING & CONDUIT NOTES: 1.46. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47. CONDUCTORS SIZED ACCORDING TO 2022 CEC 690.8, 2022 CEC 690.7. 1.48. VOLTAGE DROP LIMITED TO 2%. 1.49. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNCECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [2022 CEC 110.15 1.51.GROUNDING NOTES: 1.52. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO 2022 CEC 690.43 AND MINIMUM 2022 CEC TABLE 250.122. 1.54. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDING WITH 2022 CEC 250.134 AND 2022 250.136(A). 1.55. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 N SCALE: 3/64" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 6 kW DC CONSTRUCTION NOTES SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ PV-1 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND SPEED OF 95 MPH (3 SECOND GUST), WIND EXPOSURE B. 3. THE ROOF MEMBERS ARE 2"X 4" RAFTERS AT 24" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.7.1, CBC 3111.2.1) 6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. (15) CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTERS MOUNTED TO THE BACK OF EACH MODULE MOUNTED ON EPDM FLAT ROOF ROOF LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 LEGEND M METER MAIN COMBO CB COMBINER BOX BATT BATTERY SSP NEW SOLAR PANELS ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT PER 2022 CALIFORNIA RESIDENTIAL CODE R328.4 SUB SERVICE PANEL ACD AC DISCONNECT Roof Section 1 Roof Azimuth: 240° Roof Tilt: 2° M CB ROOF OBSTRUCTIONS BATT ACD AC D CAL-FIRE ROOF LADDER ACCESS POINT CONDO C CONDO D CONDO B GARAGE A GARAGE D GARAGE C GARAGE B CONDO A EME R S O N P L DIC K E N S P L BATT GARAGE E GARAGE F GARAGE G CONDO E CONDO F CONDO G LOCATION OF (2) ENPHASE IQ BATTERY 5P WALK W A Y WA L K W A Y LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 PRO P E R T Y L I N E PR O P E R T Y L I N E KIPL I N G P L THE HEAT DETECTOR WILL BE INTERCONNECTED TO THE SMOKE ALARMS (N) HEAT DETECTOR PR O P E R T Y L I N E CAL-FIRE ROOF LADDER ACCESS POINT SS P LOCATION OF METER MAIN COMBO. PV INTERCONNECTION POINT. LOCATION OF SUB SERVICE PANEL, (1) AC DISCONNECT, COMBINER BOX & (2) ENPHASE IQ BATTERY 5P MOUNTED ON INTERIOR WALL AND METER MAIN COMBO,(1) AC DISCONNECT MOUNTED ON EXTERIOR WALL OF A GARAGE. Signed 6/13/2024 Structural Only 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 N 6'6' SCALE: 3/32" = 1'-0" PV SYSTEM MOUNTING DETAILS UNIRAC FLASHLOC RM FOR EPDM FLAT ROOF @ 72" O.C MAX PROPOSED UNIRAC SM RACKING PROPOSED CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) PV SOLAR MODULES EXISTING 2"X 4" ROOF RAFTERS @ 24"O.C. SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ PV-2 Roof Section 1 Roof Azimuth: 240° Roof Tilt: 2° EXISTING EPDM FLAT ROOF ROOF Structural Only 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 910 10 6 21 7 9 21 7 S-5 D5 20 15 18 22121413 S-5 D4 26 1 2 54 8 3 25 24 23 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ PV-3 EPDM FLAT ROOF 1. ROOF MATERIAL:EPDM FLAT ROOF 2. ROOF STRUCTURE: RAFTERS 3. ATTACHMENT TYPE: UNIRAC FLASHLOC RM 4. MODULE MANUFACTURER: CANADIAN SOLAR 5. MODULE MODEL: CS6R-400MS-HL (BLK) (400W) 6. MODULE LENGTH: 67.8'' 7. MODULE WIDTH: 44.6" 8. MODULE WEIGHT: 49.4 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 11. RAFTERS SPACING: 24" O.C. 12. RAFTERS SIZE: 2"X 4" NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 15. TOTAL # OF ATTACHMENTS: 40 16. TOTAL AREA: 314.99 SQ. FT. 17. TOTAL WEIGHT: 741.00 LBS. 18. WEIGHT PER ATTACHMENT: 18.53 LBS. 19. DISTRIBUTED LOAD: 2.35 PSF 20. MAX. HORIZONTAL STANDOFF: 72 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 39 IN. 22. STANDOFF STAGGERING: NO 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):UNIRAC SM 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. RAFTERS SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. Signed 6/13/2024 Structural Only 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 7 PV CIRCUIT 1: 7 MODULES/PARALLEL RO O F T O P GR O U N D L E V E L - HO U S E E X T E R I O R 8 PV CIRCUIT 2: 8 MODULES/PARALLEL 12 12 1 1 (N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE 2 20A 20A N 15A (N) 15 CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) SOLAR MODULES WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTER ATTACHED TO THE BACK OF EVERY MODULE. NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH END OF THE EMT CONDUIT WITH THE WIRE THEN FREE AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL 3 40A 5 (N) ENPHASE IQBATTERY-5P-1P-NA [240V] (N) VISIBLE LOCKABLE 2 POLE 100A 'KNIFE' AC DISCONNECT (SQUARE D DU222RB) (N) ENPHASE IQBATTERY-5P-1P-NA [240] (N) 125A/240V AC COMBINER BOX 5/5C (X-IQ-AM1-240-5/5C) WITH ENPHASE IQ ENVOY COMM. GATEWAY [CRD-PCS NON-EXPORT] 1. ENVOY MUST BE NO FARTHER THAN 150' FROM THE LAST MICROINVERTER. 2. MAX DISTANCE BETWEEN ENSEMBLE DEVICES IS 50' LINE OF SIGHT WITH NO OBSTRUCTIONS. EN P H A S E I Q E N V O Y CO M M U N I C A T I O N S GA T E W A Y CELL MODEM GATEWAY WIRELESS COMM 3 (N) VISIBLE LOCKABLE 2 POLE 100A 'KNIFE' AC DISCONNECT (SQUARE D DTU223RB) CT CABLE M POINT OF DELIVERY AND INTERCONNECTION 100A EXISTING 240V/125A METER MAIN COMBO SINGLE PHASE (E) GROUNDING ELECTRODE OR (UFER) N BACKFEED BREAKER NEW 240V/200A SUB SERVICE PANEL SINGLE PHASE 70A N 100A 4 55 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ E-1 SUB SERVICE PANEL 240/120V 1Ø, 3W MAIN BUSS: 200A MAX BREAKER SIZE: (200A X 1.2) - 100A = 140A ESS DETAILS MODEL NAME ENPHASE IQ BATTERY-5P-1P-NA [240V] PEAK OUTPUT POWER 6.14 kVA TOTAL CAPACITY 5.0 kWh ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT PER 2022 CALIFORNIA RESIDENTIAL CODE R328.4 ALL EQUIPMENT LISTED IS SUBJECT TO AVAILABILITY AND MAY BE REPLACED WITH AN EQUIVALENT PRODUCT. METER # 222012989048 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ E-2 Inverter Ratings Inverter Make/Model ENPHASE IQ8PLUS-72-2-US [240V] Max DC Volt Rating 60V Max con output Power 290W Max Nominal Voltage 240V Max AC Current 1.21A Max OCPD Rating 20A DESIGN TEMPERATURES ASHRAE EXTREME LOW 2°C ASHRAE 2% HIGH 31°C PV Module Ratings @ STC Module Make/Model CANADIAN SOLAR CS6R-400MS-HL (BLK) (400W) Max Power-Point Current (Imp)12.99A Max Power-Point Voltage (Vmp)30.8V Open-Circuit Voltage (Voc)36.8V Short-Circuit Current (Isc)13.85A Max Series Fuse (OCPD)25A Nominal Maximum Power at STC (Pmax)400W Maximum System Voltage 1000V Voc Temperature Coefficient -0.26%/°C SYSTEM SUMMARY BRANCH #1 BRANCH #2 INVERTERS PER BRANCH 7 8 MAX AC CURRENT 8.47A 9.68A MAX AC OUTPUT POWER 2030W 2320W ARRAY STC POWER 6000W MAX AC CURRENT 18.15A MAX AC POWER 4350W Conduit and Conductor Schedule Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 Enphase Q cable - THWN-2 12 AWG 2 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 12 AWG 4 3 THWN-2 4 AWG 3 EMT 1" 3 THWN-2 - Ground 8 AWG 1 EMT THWN-2 THWN-2 - Ground 5 5 EMT2 1 8 AWG 10 AWG 3/4" 3/4" EMT 3/4" 2 THWN-2 - Ground 10 AWG 1 EMT 3/4" EMT 1" 4 THWN-2 3 AWG 3 EMT 1" 4 THWN-2 - Ground 8 AWG 1 EMT 1" 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: (N) SOLAR PANELS AND MICRO-INVERTERS ON ROOF SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ E-3 PV INTERCONNECTION POINT. LOCATION OF SUB SERVICE PANEL 1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE 3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(3) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 705.15(C)(4)& 690.13(B) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022:690.56(C)(2), CFC 2022: 1204.5.3 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 18.15 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 CAUTION TRI POWER SOURCES SECOND SOURCE IS PV SYSTEM THIRD SOURCE IS AC BATTERY ! LABEL LOCATION : BATTERY F.D. – ELECTRICAL BLDG DISCONNECT # 2 of 2 # 2 F.D. – ELECTRICAL BLDG DISCONNECT # 1 of 2 # 1 LOCATION OF (2) ENPHASE IQ BATTERY 5P. COMBINER BOX & (1) AC DISCONNECT EM E R S O N P L DICKENS PL KI P L I N G P L LOCATION OF METER MAIN COMBO & (1) AC DISCONNECT 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 2'-4" ME T E R M A I N C O M B O ENPHASEe ENPHASE IQ COMBINER 5/5C AC DISCONNECT 1 2' 3'-3" 1'-11" 1' ENPHASEe ENPHASE IQ BATTERY-5P-1P-NA [240V] 2 AC DISCONNECT 2' 3'-3" 1'-11" 1' ENPHASEe ENPHASE IQ BATTERY-5P-1P-NA [240V] 6" 6" 6" ON EXTERIOR WALL OF GARAGE ON INTERIOR WALL OF GARAGE SUB SERVICE PANEL INSIDE HOUSE SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ E-4 EQUIPMENT ELEVATION VIEW ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE DISCONNECT NUMBER DISCONNECTION OPERATION/EQUIPMENT/DEVICE 1 OF 2 2 OF 2 100A MAIN BREAKER 100A BLADE DISCONNECT ENERGY SOURCE NEW SOLAR PV+ ESS UTILITY SERVICE 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-10 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-11 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-12 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-13 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-1 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-2 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-3 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-4 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-5 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-6 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-7 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-8 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 SHEET CONTRACTOR ILUM SOLAR 3050 BRADFORD PL APT G, SANTA ANA, CA 92707 APN:93312042 DATE:6/11/2024 ALCANTRA RESIDENCE License#:1092865, C-46 & C-10 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHQ S-9 3050 S Bradford Pl Unit# G- 101119758 & 20183184 7/17/2024 3050 S Bradford Pl Unit# G- 101119758 & 201831847/17/2024 IL□m ENERGY SOLUTIONS November 16, 2023 To Whom It May Concern: This letter is to confirm that Colton Kelsey, Sharonda Holt, Matt Morales, R eyna Carrillo, Joseph Pratti and Hector Silva are authorized agents for ILUM SOLAR and have the permission to pull permits and city business licenses for our company. Should you have any questions, please do not hesitate to contact us at 888-696-4586 Sincerely, 8e11jAw.i11 Her11rtedf CSLB: 1092865 / 3050 S Bradford Pl Unit# G- 101119758 & 201831847/17/2024 CALIFORNIA ACKNOWLEDGMEN-T CIVIL CODE § 1189 A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. State of California County of SAL-C c:L fl-4' A. -f 0 } onWov, ll� 2-ol3 before me, lc:,ffl� EJl,ro if,IJ0/v9 Pv!olt"e-Datel /-)o_(_V\_ S _H-1-�-e-J�s-,�rt�N�a-m-e-an...,d�T.�it-le_o,_f_t_li -1e-O-ffi�i�ce�r���-personally appeared �13�_,e:_n-r-+j_g.........._m�1'_,_n _____ r(�c:.. _____ �T ______________ _ 0 Name(s) of Signer(s) who proved to me on the basis of satisfactory evidence to be the person(81 whose nam� •is/a.re subscribed to the within instrument and acknowledged to me that he/she'ft� executed the same in his/her/th.eir authorized capacity(ies)<'and that by his/hef1thfai1' signature(:;)'on the instrument the person�),.>or the entity upon behalf of which the perso�acted, executed the instrument. Place Notary Seal andlbr Stamp Above I certify under PENAL TY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature ---�---= ___ L_--........___.._· ______ _ Signature of Notary Public OPTIONAL Completing this information can deter alteration of the document or fraudulent reattachment of this form to an unintended document. Description of Attached Document Title or Type of Document: ___________________________ _ Document Date: _____________________ Number of Pages: ____ _ Signer(s) Other Than Named Above: ________________________ _ Capacity(ies) Claimed by Signer(s) Signer's Name: ____________ _ □Corporate Officer -Title(s): ______ _□Partner -□ Limited □ General□Individual □Attorney in Fact□Trustee □Guardian or Conservator□Other:Signer is Representing: _________ _ ©2018 National Notary Association Signer's Name: □Corporate Officer -Title(s): ______ _□Partner -□ Limited □ General□Individual □Attorney in Fact□Trustee □Guardian or Conservator□Other:Signer is Representing: _________ _ 3050 S Bradford Pl Unit# G- 101119758 & 201831847/17/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 3050 Bradford Pl. Unit G Santa Ana Ca 92707 Ilum Solar 1092865 Reyna G. Carrillo 562.525.2868 6.19.24 rcarrillo@ilumsolar.com 3050 S Bradford Pl Unit# G- 101119758 & 201831847/17/2024