HomeMy WebLinkAbout2309 N Spurgeon St - PlanGENERAL NOTES PHOTOVOLTAIC NOTES AERIAL VIEW VICINITY MAP PV-0 COVER PAGE PROJECT DESCRIPTION:SCOPE:SCOPE: DATE:11/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT SOLAR MODULES: NEW SYSTEM SIZE: DC STC: 6.56 kW AC CEC: 5.93 kW INVERTERS OUTPUT: AC: 11.40 kW 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS. 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8. INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION. 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED. 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS. 12. ALL WORK SHALL BE IN ACCORD WITH THE 2022 CBC, 2022 CEC AND 2022 NEC WITH SPECIAL EMPHASIS ON ARTICLE 690. 13. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6). 14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER SEC 250.122 15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 16. PER ART NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. SHEET INDEX PV-2 PV-3 PV-4 D-1 D-2 D-3 D-4 D-5 D-6 D-7 SITE PLAN THREE LINE DIAGRAM DESCRIPTION PV-0 COVER PAGE PV-1 NOTES: ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED AND LICENSED ELECTRICAL CONTRACTOR. ALL SOLAR MODULES SHALL BE UL LISTED 1703 & CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741 CERTIFIED & CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. THE ELECTRICAL CONTRACTOR IS ADVISED THAT ALL DRAWINGS AND COMPONENT MANUALS ARE TO BE UNDERSTOOD PRIOR TO INSTALLATION. THE CONTRACTOR IS ADVISED TO HAVE ALL SWITCHES IN THE OFF POSITION AND FUSES REMOVED PRIOR TO INSTALLATION OF FUSE-BEARING COMPONENTS. THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL 1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PV SYSTEM WHEN THE UTILITY GRID IS NOT OPERATIONAL. PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS ARE OBTAINED FROM THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. THE METHOD OF ATTACHMENT CREATES A UNIFIED STRUCTURE TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. SOLAR MODULES WILL BE SECURED TO THE EXISTING ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PV SYSTEM. ALL STRUCTURAL DESIGN AND INSTALLATION COMPONENTS ARE THE RESPONSIBILITY OF OTHERS AND OUTSIDE THE SCOPE OF THIS DOCUMENT. ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR SITE CONDITIONS. CONNECTORS SHALL BE TORQUED PER DEVICE LISTING OR ENGINEERING RECOMMENDATIONS. ALL ROOFING REPAIR MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOF IN MANUFACTURER'S INSTALLATION REQUIREMENTS. EXISTING: MSP BUS: MAIN BREAKER: 1P, 3W, 120/240V 200A 200A ELECTRICAL INFORMATION THE FOLLOWING PLANS INCLUDES INSTALLATION OF TWO TESLA POWERWALL 3 LITIUM-ION AC BATTERIES. EACH BATTERY IS SINGLE ASSEMBLY WITH INVERTER. THESE BATTERIES WILL BE INSTALLED OUTSIDE TO EXISTING STUDS AND HAVE A CAPACITY OF 13.5 KWH. WITH TOTAL CAPACITY OF 27.0 KWH POWERWALL 3 MOUNTING DETAILS LOAD CALCULATION BSP SYSTEM CONFIGURATION (2) 11.5 kW TESLA POWERWALL 3 1707000-xx-y (120/240V) (ALL-IN-ONE SOLAR & BATTERY SYSTEM (DC-COUPLED SOLAR)) APPLICABLE CODES 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 NATIONAL ELECTRICAL CODE 2022 CALIFORNIA FIRE CODE ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES EQUIPMENT ELEVATION INVERTER & ESS: POWERWALL 3 MOUNTING DETAILS POWERWALL 3 MOUNTING DETAILS NOTE: SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE PROVIDED FOR THE DWELLING PER CRC R314 AND R315. TESLA GATEWAY DATA SHEET (19) JA SOLAR 395W (JAM54S31-395/MR)EXISTING EXISTING NEW INVERTER: (1) TIGO 11.4KW (TSI-11.4K-US) (120/240V) SOLAR MODULES: (16) SOLAREVER 410W (SE-182*91-410M-108) INVERTER: (1) ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A) (120/240V) INVERTER & ESS DATA SHEET EXISTING SYSTEM SIZE: DC STC: 7.51 kW AC CEC: 6.73 kW INVERTERS OUTPUT: AC: 3.60 kW NEW NEW ELECTRICAL CALCULATION ATTACHMENT LAYOUT STRUCTURAL DETAIL CODE REQUIRED SIGNAGE PV-5 PV-6 BATTERY REQUIRED SIGNAGEPV-7 PV-8 MODULE DATA SHEET RACKING DATA SHEET ATTACHMENT DATA SHEET GROUNDING SPECS RACKING CERTIFICATION RACKING DETAILS INVERTER DATA SHEET OPTIMIZER DATA SHEET D-8 D-9 D-10 D-11 D-12 D-13 D-14 D-15 RSD DEVICE DATA SHEETD-16 BLDG#101121197 ELEC#20184262 APPROVALS ELEC - MSmith 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT ROOF PLAN PV-1 SCALE 0 5 20ft10 ELECTRICAL EQUIPMENT INFORMATION #Quantity Description - 19 (E)JA SOLAR 395W (JAM54S31-395/MR) Modules - 19 (E) TIGO TS4-A-O Optimizers -16 (N)Solarever 410W (SE-182*91-410M-108) Modules -16 (N) TIGO TS4-A-O Optimizers 1 1 (N) Junction-Box 2 1 (E) ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A) (120/240V) Inverter 3 1 (E)30A Non-Fused AC Disconnect (120/240V) 4 1 (N) TIGO 11.4KW (TSI-11.4K-US) (120/240V) Inverter 5 1 (N)60A Non-Fused AC Disconnect (120/240V) 6 2 (N) 11.5 kW TESLA POWERWALL 3 1707000-xx-y (120/240V) (All-In-One Solar & Battery System (DC-Coupled Solar)) (Page D-1) 7 2 (N)60A Non-Fused AC Disconnect (120/240V) 8 1 (N) Tesla Backup Gateway 2 (120/240V) (Page D-2) 9 1 (N)200A Back-up Load Panel (120/240V) 10 1 (E)200A Main Service Panel (120/240V) Pu b l i c S i d e w a l k N S p u r g e o n S t Driveway 98' 62' Existing Solar System Existing Solar System Gate Gate [2] [3] [4] [5] [8] [9] [6] [7] [10] Solar Array 1 5 Solarever 410W 5 TIGO Optimizers Pitch: 20 Deg Orientation: 270 Deg [1] Solar Array 2 7 Solarever 410W 7 TIGO Optimizers Pitch: 20 Deg Orientation: 270 Deg Solar Array 3 4 Solarever 410W 4 TIGO Optimizers Pitch: 20 Deg Orientation: 90 Deg A A A A A A A A B B B B B B B B STRING CONFIGURATION A 8 MODULES B 8 MODULES FIRE SETBACK (36'' TYP) FIRE SETBACK (18'' TYP) Roof access is not located in areas that require placement of ground ladders over exterior wall openings CRC R331.4.1. PROPERTY LINE ROOF ACCESS ROOF ACCESS (N) Number of modules 16 (E) Number of modules 19 Module area (sq.ft)21 Total Module area (sq.ft)735 Total area of roof (sq.ft)2300 Total area of array covered in the roof (%)32.0 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-8 RACKING DETAILS 2309 N Spurgeon St12/11/2024 ATTACHMENT LAYOUT SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT PV-4 SOLAR ARRAY MOUNTING RAIL TYPE: UNIRAC STANDARD RAIL SOLAR ARRAY ATTACHMENT TYPE: UNIRAC FLASHLOC ATTACHMENT SPACING: 72'' MAX FRAMING: TRUSSES 2'' x 4'' @ 24'' O.C FINISHED ROOF SURFACE IS ONE LAYER OF COMPOSITION SHINGLE. WIND SPEED: 110 mph FOR EXPOSURE C SNOW LOAD: 0 psf 72'' 24'' 2309 N Spurgeon St12/11/2024 STRUCTURAL DETAIL SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT PV-5 WEIGHT LOAD CALCULATION MODULE WEIGHT(LBS):45 NUMBER OF MODULES:16 OPTIMIZER WEIGHT(LBS):1.08 NUMBER OF OPTIMIZERS:16 TOTAL WEIGHT OF MODULES(LBS):720 SOLAR RACKING WEIGHT(LBS):144 TOTAL RSD WEIGHT(LBS):17 TOTAL SYSTEM WEIGHT(LBS):881 NUMBER OF ATTACHMENTS:34 LOADING PER ATTACHMENT(LBS):25.9 SOLAR ARRAY DEAD LOAD(LBS/FT2):2.66 TOTAL SOLAR AREA(SQFT):331 TOTAL ROOF AREA(SQFT):2300 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%)14.4 MID-CLAMP AND END-CLAMP ANATOMY ROOF FRAMING DETAILS MODULE TO MODULE & MODULE TO RAIL T-BOLT GROUNDING LUG RAIL TO RAIL UNIVERSAL AF END CLAMP 15 8" UNIVERSAL AF MID CLAMP 11 2" 13 16"11 4" 30mm to 46mm MODULE FRAME 30mm to 46mm MODULE FRAME 1 2" UNIVERSAL MID CLAMP UNIVERSAL END CLAMP BONDING SPLICE BAR 1 1 2" 15 16" 4" 5/16"-18 TYPE F THREAD CUTTING SCREWS INCLUDED ATTACHMENT DETAIL- UNIRAC FLASHLOC NOTE:ROOF ATTACHMENTS WILL HAVE A MINIMUM OF 2.5" EMBEDMENT IN RAFTER. NOTE:STANDOFF LAG BOLTS ARE STAINLESS STEEL (SS) SCALE:NTS 6" MAX UNIRAC STANDARD RAIL-168" PV MODULES GROUNDING & END/MID CLAMP SS SERRATED T-BOLT SS SERRATED FLANGE NUT FLASHLOC BASE 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER WITH MIN 2 1/2" THREAD EMBEDMENT 5/16" X 3.5" LAG SCREW 1 BOLT PER PENETRATION MODULE LOAD BEARING WALL SCALE:NTS 20o 2''x4'' TRUSSES @24'' O.C. 2''x6'' BLOCKING 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT EQUIPMENT ELEVATION PV-8 Tesla Powerwall 3 BATTERY DISCONNECT Min 3' BACKUP LOADS PANEL TESLA GATEWAY SOLAR INVERTER SOLAR DISCONNECT SERVICE POINT & UTILITY METERING (E) SOLAR INVERTER (E) SOLAR DISCONNECT 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:11/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT PV-2 THREE LINE DIAGRAM NOTE: Photovoltaic system is rapid shut down ready 1 2 9 INV G N L2 L1 EXISTING CONDUIT EXISTING ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A) INVERTER EXISTING 3/4'' EMT CONDUIT (3) THWN-2, #10 (L1, L2, N) (1) #8, EGC CU 1 2 10 TESLA POWERWALL 3 L1 L2 N GG - + - + TESLA BATTERY TESLA POWERWALL 3 L1 L2 N GG - + - + TESLA BATTERY NEW 3/4'' EMT CONDUIT (3) THWN-2, #6 (L1, L2, N) (1) #8, EGC CU L1 L2 G L1 L2 G N N 8 NEW 3/4'' EMT CONDUIT (3) THWN-2, #6 (L1, L2, N) (1) #8, EGC CU L1 L2 G L1 L2 G N N N G L2L1 L2 L1 CTRL L2 L1 L1 L1 L2 L1 L2 L1 L2 L1 L1 L1 L2 L2 L2 N G L2 N G NEW 60A BREAKER NOTE: AFCI PROTECTION IS REQUIRED FOR CIRCUITS RELOCATED MORE THAN 6 FT. PER SECT. 210.12(B). NEW WIRING 2'' EMT CONDUIT (3) THWN-2, #3/0 (L1, L2, N) (1) #4, EGC CU NEW 200A OCPD L2 L1 L2 L1 L1 L2 G L1 L2 G N N 1 2 8 INV G N L2 L1 EXISTING SOLAR SYSTEM (19) JA SOLAR 395W MODULES TIGO 11.4KW (TSI-11.4K-US) INVERTER 1 2 8 L1 L2 G L1 L2 G N N 1 2 6 4 7 5 8 9 9 10 11 INSTALL 2P 20A CB(PV) FURTHEST FROM MAIN FEEDER CB 8' Minimum Embedment Rod at 6' From Equipment Ground Conductor Unless Existing Ground is UFER. N G M L1 L1 N L2 N L2 N L2 L1 L1 L2 EXISTING 200A CENTER FEED OCPD TO UTILITY GRID NEW 2P 200A 12 NOTE: 705.12.(B)(3)(3) connection method will be used. A B ELECTRICAL EQUIPMENT INFORMATION #Quantity Description -19 (E) JA SOLAR 395W (JAM54S31-395/MR) Modules 1 16 (N) Solarever 410W (SE-182*91-410M-108) Modules 2 16 (N) TIGO TS4-A-O Optimizers 3 1 (N) Junction-Box 4 1 (E) ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A) (120/240V) Inverter 5 1 (E) 30A Non-Fused AC Disconnect (120/240V) 6 1 (N) TIGO 11.4KW (TSI-11.4K-US) (120/240V) Inverter 7 1 (N) 60A Non-Fused AC Disconnect (120/240V) 8 2 (N) 11.5 kW TESLA POWERWALL 3 1707000-xx-y (120/240V) (All-In-One Solar & Battery System (DC-Coupled Solar)) (Page D-1) 9 2 (N) 60A Non-Fused AC Disconnect (120/240V) 10 1 (N) Tesla Backup Gateway 2 (120/240V) (Page D-2) 11 1 (N) 200A Back-up Load Panel (120/240V) 12 1 (E) 200A Main Service Panel (120/240V) 3 J/B C C STRINGS A,B (8) SOLAREVER 410W MODULES (8) TIGO TS4-A-O OPTIMIZERS STRING CALCULATION Number of Modules Module VOC Coefficient Total Inp. Voltage Max Inp. Voltage 8 37.12 1.12 332.6V <=600V [1] [2] [5] EXISTING ABB RAPID SHUTDOWN DEVICE SEE PAGE D-16 [6] Rerouted circuits will be 10 x #8 wires, and 33 x #10 wires Multiple conduit will be used 1 x 1 1/4'' EMT and 3 x 1'' EMT Conduits [7] 2309 N Spurgeon St12/11/2024 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). 2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS TO CEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRODE CONDUCTOR SIZED PER CEC 250.66. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(A). 8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. 10.CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE CEC 310.15(B)(16). SCOPE:SCOPE: DATE:11/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT PV-3 ELECTRICAL CALCULATION WIRE SIZE CALCULATION WIRE TAG#WIRE TYPE AND SIZE QUANTITY OF WIRES GROUNDING SIZE WIRE AMPACITY TEMPERATURE CONDUIT TYPE ABOVE ROOF TEMP. DERATE FACTOR ADJUSTING FACTOR CORRECTED CONDUCTOR AMP CURRENT AMP A PV WIRE #10 2 #6, BARE CU 40 A 90°Free in the air >3.5 - 12''0.71 1 N/A 28.4 18.8 B THWN-2 #10 2x(DC+,DC-)4 #8, EGC CU 40 A 90°3/4'' EMT >3.5 - 12''0.71 0.8 4 Thru 6 Wires 22.7 18.8 C THWN-2 #6 (L1,L2,N)3 #8, EGC CU 75 A 90°3/4'' EMT ALONG THE WALL 0.91 1 N/A 68.3 60.0 NEW PV SYSTEM OUTPUT CALCULATION 1 TIGO 11.4KW (TSI-11.4K-US)97.5 % 16 Solarever 410W (SE-182*91-410M-108)410.0 W Pmax (PTC Rating)380.0 W 1 Inverter Output 11400 W Max DC Output 16 * 410.0 6.56 KW Max AC Output 16 * 380.0 * 0.975 5.93 KW Inverters Output:1 * 11400.0 11.40 KW WIRE AMPACITY DC #RSD AMP CONSIDER CONTINUOUS COEFFICIENT CURRENT AMP A 15 1.25 18.8 B 15 1.25 18.8 WIRE AMPACITY AC # INVERTER MAX OUTPUT CURRENT QUANTITY CONSIDER CONTINUOUS COEFFICIENT CURRENT AMP C 48.0 1 1.25 60.0 EXISTING PV SYSTEM OUTPUT CALCULATION 1 ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A)96.0 % 19 JA SOLAR 395W (JAM54S31-395/MR)395.0 W Pmax (PTC Rating)368.7 W 1 Inverter Output 3600 W Max DC Output 19 * 395.0 7.51 KW Max AC Output 19 * 368.7 * 0.960 6.73 KW Inverters Output:1 * 3600.0 3.60 KW PANEL SCHEDULE BREAKER AMP PHOLES AMOUNT DESCRIPTION TYPE 20 1 1 Light Single 20 1 1 Bedroom Light Single 20 1 4 Kitchen Light Multi Wire Circuit 20 1 4 Kitchen Plug Multi Wire Circuit 30 2 1 Dryer - 40 2 1 AC Unit - 30 2 1 AC Unit - 20 1 1 El. Plugs Multi Wire Circuit 20 1 1 Washer Multi Wire Circuit 20 1 1 Garage Multi Wire Circuit 15 1 2 1st Floor Lights Multi Wire Circuit 20 1 2 1st Floor Plugs Multi Wire Circuit 50 2 1 EV Charger - 20 1 1 Bathroom+Bedroom Switch Multi Wire Circuit 50 2 1 SPA - [3] Note: All multi-wire circuits to be bundled with a single neutral. [4] 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:11/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT PV-6 CODE REQUIRED SIGNAGE CAUTION MULTIPLE SOURCES OF POWER PHOTOVOLTAIC ARRAY 14 METER MAIN SERVICE PANEL 7 9 12 13 AC DISCONNECT * if applicable 7 SUB-PANEL * if applicable 7 9 81110 7 9 6 PV SUB-PANEL * if applicable 81110 INVERTER *if applicable 3 INTEGRATED DC DISCONNECT 4 5 J BOX 1 2 8 10 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS 1 (TO BE LOCATED ON SUB-PANEL ONLY WHEN SUB-PANEL IS DEDICATED FOR PV ONLY) PV SUB-PANEL ONLY CAUTION AUTHORIZED SOLAR PERSONNAL ONLY! WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. RAPID SHUT DOWN SWITCH FOR SOLAR PV SYSTEM 705.12 (D)(3) CAUTION DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT: 48.0 A MAX NOMINAL AC OPERATING VOLTAGE: 240 Vac THIS PANEL FED BY MULTIPLE SOURCES (UTILITY & SOLAR) WARNING! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ALL SIGNAGE/LABELS SHALL BE IN THE FOLLOWING FORMAT: 1. WHITE LETTERING ON A RED BACKGROUND AND WEATHER RESISTANT 2. MINIMUM 3/8" LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT, NON-BOLD 5. SHALL BE IN ACCORDANCE WITH APPROPRIATE SECTIONS, TABLES AND ARTICLES OF THE NEC, IFC. (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) WARNING: PHOTOVOLTAIC POWER SOURCE2 14 3 4 5 6 7 (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. SOLAR WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE 9 10 11 8 (STICKER LOCATED ON THE PV SUB PANEL) 12 13 15 TRI POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM 15 PLAQUES SHALL BE METAL OR PLASTIC, WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE RATED MAX POWER POINT CURRENT- 13.08 AMPS RATED MAX POWER POINT VOLTAGE- 31.35 VOLTS MAXIMUM SYSTEM VOLTAGE- 41.57 VOLTS SHORT CIRCUIT CURRENT- 11.26 AMPS N S p u r g e o n S t TESLA BATTERY BATTERY DISCONNECT SERVICE POINT & UTILITY METERING SOLAR INVERTER SOLAR DISCONNECT SOLAR INVERTER SOLAR DISCONNECT CEC 705.10 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT PV-7 1 2 3 WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. REQ'D BY: NEC 705.12(B)(2)(3)(b) LABEL LOCATION: BATTERY BREAKERS REQ'D BY: NEC 705.12(B)(2)(3)(b) LABEL LOCATION: PV BREAKERS 4 FIRST SOURCE IS UTILITY ELECTRICAL GRID SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PV INVERTER CAUTION-TRI POWER SOURCE REQ'D BY: NEC 705.10 LABEL LOCATION: SUB PANEL OR BACKUP LOADS PANEL, BATTERY, INVERTER OUTPUT PANEL, MAIN SERVICE PANEL, METER/MAIN, AND PV AC DISCONNECT 5 NOMINAL ESS VOLTAGE: MAX SHORT-CIRCUIT CURRENT: ASSOCIATED CLEARING TIME: DATE CALCULATION WAS PERFORMED: WARNING ARC FLASH & SHOCK HAZARD 240V 48.0A 60ms 09/19/2024 LABEL LOCATION: BATTERY DISCONNECT 6 DO NOT ADD LOADS REQ'D BY: NEC 705.10 LABEL LOCATION: SUB PANEL OR BACKUP LOADS PANEL, BATTERY, INVERTER OUTPUT PANEL, MAIN SERVICE PANEL, METER/MAIN, AND PV AC DISCONNECT PLACARDS NOTES 1. CEC ARTICLES 690 AND 705 AND CRC SECTION R331 MARKINGS SHOW HEREON 2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR B. RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK C. ARIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS. 5. THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. 6. WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(8) FIELD MARKING]. 7. ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] BATTERY DISCONNECT DO NOT RELOCATE THIS OVERCURRENT DEVICE PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. BATTERY SYSTEM RATED AC OUTPUT CURRENT PV SYSTEM RATED AC OUTPUT CURRENT PV SYSTEM RATED AC OUTPUT VOLTAGE PV SYSTEM POWER PHASE 48.0A 64.0A 240V SINGLE MAIN SERVICE PANEL 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 (STICKER LOCATED ON THE ESS DISCONNECT) AC DISCONNECT ENERGY STORAGE SYSTEM INVERTER STORAGE BATTERY BATTERY DISCONNECT TESLA GATEWAY TESLA BATTERY BATTERY DISCONNECT REQ'D BY: NEC 705.12(B)(3) BATTERY DISCONNECT INVERTER STORAGE BATTERY SOLAR INVERTER SOLAR PANELS SOLAR DISCONNECT SOLAR INVERTER SOLAR PANELS SOLAR DISCONNECT BACKUP LOADS PANEL N Spurgeon St SERVICE POINT & UTILITY METERING SOLAR INVERTER SOLAR DISCONNECT SOLAR INVERTER SOLAR DISCONNECT BACK-UP LOADS PANEL TESLA GATEWAY PHOTOVOLTAIC ARRAY ON ROOF PHOTOVOLTAIC ARRAY ON ROOF PHOTOVOLTAIC ARRAY ON ROOF BATTERY REQUIRED SIGNAGE 2309 N Spurgeon St12/11/2024 D-1 SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT MODULE DATA SHEET 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-10 TESLA GATEWAY DATA SHEET 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-11 POWERWALL 3 MOUNTING DETAILS 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-12 POWERWALL 3 MOUNTING DETAILS 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-13 POWERWALL 3 MOUNTING DETAILS 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-14 SYSTEM CONFIGURATION 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-15 LOAD CALCULATION Standard Method for Dwelling Service Calculations Worksheet for the EVITP Step 7: Article 220.60 – Noncoincident Loads 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 Air conditioning Step 1: Section 220.12 – Lighting load for listed occupancies.32 A x 240 V x 1 =7,680 VA 2,614 Sq.ft x 3 VA =7,842 VA 24 A x 240 V x 1 =5,760 VA Step 2 : Section 220.52 – Small Appliance and Laundry load.0 A x 240 V x 1 =0 VA 2,614 Sq.ft x 3 VA =7,842 VA Other Loads 2 Appliances Circuits x 1,500 VA =3,000 VA 0 A x 240 V x 1 =0 VA 1 Laundry Circuit x 1,500 VA =1,500 VA 0 A x 240 V x 1 =0 VA General Lighting Load =12,342 VA 0 A x 240 V x 1 =0 VA Step 3: Table 220.42 Apply demand factors to the general lighting load.Total Load =13,440 VA First 3,000 VA at 100%=3,000 VA Step 8: 220.50 – 25% of largest motor FLA.* Remainder at 35%9,342 x 0.35 =3270 VA 50 A x 240 V x 25%=3,000 VA Net Load =6270 VA Step 9: 220.14(A) Other Loads – EVSE Step 4: 220.53 – Demand Factor – Appliance Loads – Dwelling Units.50 A x 240 V x 1 =12,000 VA Disposal =1,300 VA Sum of Calculated Loads Dishwasher =1,300 VA Lighting, Sm. Appliance, Laundry (Step 3)=6,270 VA Refrigerator =1,300 VA Fastened in Place Appliances (Step 4)=3,675 VA Microwave =1,000 VA Clothes Dryer (Step 5)=5,000 VA =0 VA Cooking Equipment (Step 6)=0 VA =0 VA Noncoincedent Heat – A/C (Step 7)=13,440 VA =0 VA 25% of Largest Motor (Step 8)=3,000 VA =0 VA Other Loads – (Step 9)=12,000 VA =0 VA Total Calculated Load =43,385 VA Total =4,900 VA Step 10: Table 310.15 (B)(6) – Size the service and conductors. 75% of total; four or more appliances =3,675 VA 43,385 VA/240V =180.770 A Step 5: 220.54 – Clothes Dryer – The greater of 5 kW or nameplate value.Conductor Size CU AL 5,000 kW Electric Dryer =5,000 VA Step 10: Table 310.15 (B)(6) – Size the service and conductors. Step 6: Table 220.55 -  Household cooking Equipment GEC Size CU AL Oven =0 VA * Remember that although the voltages shown in the tables in Article 430 indicate that motors are rated for 115,230 and 460 Volts, Section 220.5(A) requires nominal voltages of 120, 240 and 480 Volts to be used for load calculations. Range =0 VA =0 VA Total =0 VA 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:11/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-16 RSD DEVICE DATA SHEET [6] 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:09/19/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-2 INVERTER DATA SHEET 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-3 OPTIMIZER DATA SHEET 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-4 RACKING DATA SHEET 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-5 GROUNDING SPECS 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-6 ATTACHMENT DATA SHEET 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-7 RACKING CERTIFICATION 2309 N Spurgeon St12/11/2024 SCOPE:SCOPE: DATE:08/29/2024 SCALE:AS NOTED PAPER SIZE:17"x11" CUSTOMER INFORMATION BUILDING INFO: OMAR NASSER NAME: DOUG RISK ADDRESS: 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 CITY OF SANTA ANA UTILITY: SCE COMPANY NAME: TREEPUBLIC LICENSE:# 996593 ADDRESS: 3521 JACK NORTHROP AVE, HAWTHORNE CA 90250 PHONE: (800) 701-8073 6.56 KW DC Roof Mounted PV Electrical System 16 - Solarever 410W PV Modules 1 - Tigo 11.4KW Inverter 2 - Tesla Powerwall 3 Battery TWO STORY BUILDING ROOF TYPE: COMPOSITION SHINGLE ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C CONSTRUCTION TYPE:V-B OCCUPANCY GROUP: R3 FIRE SPRINKLERS: NO MOUNTING SYSTEM: IRONRIDGE RACKING PARCEL NUMBER: 00307232 LOT AREA: 6,000 SQFT LIVING AREA: 2,614 SQFT D-9 INVERTER & ESS DATA SHEET 2309 N Spurgeon St12/11/2024 State of Florida County of Broward This foregoing instrument was acknowledged before me by means of online notarization, this 06/05/2024 by Omar Nasser. Beverly Y Wimberly ___ Personally Known OR ___ Produced Identification Type of Identification Produced California DL 2309 N Spurgeon St12/11/2024 Address | City, St Zip Code SANTA ANA CITY PERMIT STAFF A 2309 N. Spurgeon St, Santa Ana, CA 92706. Please remove Solgen Construction, LLC as my contractor and replace with TreePublic as my new contractor. Please contact me if you have any questions. TreePublic License # 996593 3521 Jack Northrop Ave. Hawthorne, CA 90250 800-701-8073 SINCERELY, CAMILLE PEDROZA 714 -390 -6922 October 11 , 2 0 2 4 Contractor Info: I Camille Pedroza residing at: 2309 North Spurgeon st, Santa Ana, CA, 92706 Hereby authorize Treepublic Solar to install solar panels at my residence and pull any necessary Permits on my behalf. Please feel free to contact me if any additional information or documentation is required. 2309 N Spurgeon St12/11/2024 Address | City, St Zip Code September 20, 2024 SANTA ANA CITY PERMIT STAFF EVELYN LAROCCA This letter is to change contractors on my solar project at 2309 N. Spurgeon St, Santa Ana, CA 92706. Please remove Solgen Construction, LLC as my contractor and replace with TreePublic as my new contractor. Please contact me if you have any questions. New Contractor Info: TreePublic License # 996593 3521 Jack Northrop Ave. Hawthorne, CA 90250 800-701-8073 SINCERELY, CAMILLE PEDROZA 714 -390 -6922 2309 N Spurgeon St12/11/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2309 N Spurgeon Str, Santa Ana, CA, Treepublic Solar 996593 x x x x x x x x x x Robert Hayrapetyan 818-926-9307 permits@treepublic.com 10.04.24 2309 N Spurgeon St12/11/2024 treepublic Attn.: To Whom It May Concern re job:DOUG RISK 2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 Design Criteria: Code:2022 CBC ASCE 7-16 Live Load:20 psf Ult Wind Speed:110 mph Exposure Cat:C Ground Snow:0 psf Min Roof Snow:NA AHZ Consulting Engineers Inc. Professional Engineer projects@ahzengineers.com 10/8/2024 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. www.ahzengineers.com 2309 N Spurgeon St12/11/2024 Job Code: DOUG RISK 2 of 6 Roof Properties: Roof Type = Roof Pitch (deg) = Mean Roof Height (ft) = Attachment Trib Width (ft) = Attachment Spacing (ft) = Framing Type = Framing Size = Framing OC Spacing (in.) = Section Thickness, b (in.) = Section Depth, d (in.) = Section Modulus, Sx (in.^3) = Moment of Inertia, Ix (in.^4) = Framing Span (ft) = Deflection Limit D+L (in.) = Deflection Limit S or W (in.) = Framing Upgrade = Sister Size = Wood Species = Wood Fb (psi) = Wood Fv (psi) = Wood E (psi) = CD (Wind) = CD (Snow) = CM = Ct = CL = Ci = CF = Cfu = Cr = F'b_wind (psi) = F'b_snow (psi) = F'v_wind (psi) = F'v_snow (psi) = M_allowable_wind (lb-ft) = M_allowable_snow (lb-ft) = V_allowable_wind (lbs) = V_allowable_snow (lbs) = E' (psi) = 725 1600000 456 1008 207 634 1785 288 1.15 2484 1.5 1.00 1.0 1.6 1.15 180 1600000 DF #2 900 Adequate NA 0.93 7 1.4 3.1 5.4 1.5 3.5 2x4 24 6 Truss 13 3.25 Shingle 20 Roof 1 www.ahzengineers.com 2309 N Spurgeon St12/11/2024 Job Code: DOUG RISK 3 of 6 Load Calculation: Panels Dead Load (psf) = Roofing Weight (psf) = Decking Weight (psf) = Framing Weight (psf) = Misc. Additional Weight (psf) = Existing Dead Load (psf) = Total Dead Load (psf) = Ultimate Wind Speed (mph) = Directionality Factor, kd = Topographic Factor, kzt = Velocity Press Exp Factor, kz = Ground Elevation Factor, ke = Velocity Pressure, qz (psf) = Array Edge Factor, γE = Solar Equalization Factor, γa = External Pressure Up, GCp_1 = External Pressure Up, GCp_2 = External Pressure Up, GCp_3 = External Pressure Down, GCp = Design Pressure Up, p_1 (psf) = Design Pressure Up, p_2 (psf) = Design Pressure Up, p_3 (psf) = Design Pressure Down, p (psf) = Hardware Checks: Ref. Widthrawal Value, W (lb/in) = (CM = Ct = Ceg = 1.0) CD = Adjusted Widthrawal Value, W' (lb/in) = Lag Penetration, p (in.) = Allowable Widthrawal Force, W'p (lbs) = Applied Uplift Force (lbs) = 1064 -516 426 2.5 266 1.6 Lag Screw Checks: Roof 1 16.0 -50.8 -60.6 0.6 -39.1 -2.6 -3.1 1.25 0.70 -2 0.85 1.00 22.4 110 0.85 1.0 Roof 1 Wind Load Calculations: 6.6 9.6 0.6 1.0 3.0 2.0 Dead Load Calculations: 3.0 Roof 1 www.ahzengineers.com 2309 N Spurgeon St12/11/2024 Job Code: DOUG RISK 4 of 6 Uplift DCR = Ref. Lateral Value, Z (lbs) = (CM = Ct = CΔ = Ceg = 1.0) CD = Adjusted Lateral Value, Z' (lbs) = Applied Laeral Force (lbs) = Angle of Resultant Force, α (deg) = Adjusted Interaction Lateral Value, Z'α (lbs) = Lateral DCR = Roof Framing Checks: LC1: D+S Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC2: D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC3: D+0.75(S+0.6W) Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC4: 0.6D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = 0.50 0.39 634 1008 320 395 0.52 0.24 634 1008 327 245 0.62 0.29 634 1008 391 292 0.29 0.14 456 725 105 Force Checks: Roof 1 134 1059 0.02 20 88 0.9 243 0.49 270 www.ahzengineers.com 2309 N Spurgeon St12/11/2024 Job Code: DOUG RISK 5 of 6 LC1: D+L Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC2: S Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC3: W (Down) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC4: W (Up) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Seismic Check: Wall Weight (psf) = Tributary Wall Area (ft2) = Total Wall Weight (lbs) = Roof Weight (psf) = Roof Area (ft2) = Total Roof Weight (lbs) = Total Existing Weight (lbs) = Total Additional PV Weight (lbs) = (Existing W + Additional W)/(Existing W) =103% The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability: Additional PV Weight: 1030 Weight Increase: 1000 17000 7 2400 15844 32844 0.22 Existing Weight: 17 -0.20 0.93 0.93 0.09 0.00 0.08 0.00 0.93 1.4 0.06 Deflection Checks (Service Level): Roof 1 0.08 www.ahzengineers.com 2309 N Spurgeon St12/11/2024 Job Code: DOUG RISK 6 of 6 Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. www.ahzengineers.com 2309 N Spurgeon St12/11/2024