Loading...
HomeMy WebLinkAbout201 E MacArthur Blvd - PlanROOFTOP ANTENNA TITLE SHEET SITE NUMBER: SITE NAME: SITE TYPE: ADDRESS: COUNTY: JURISDICTION: APPROVALS: PROJECT DIRECTORY: CONSULTING TEAM: SHEET INDEX: CITY OF SANTA ANA DOUBLE TREE HOTEL SC071 LA02834A ORANGE COUNTY NO. DATE: DESCRIPTION: BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 E MACARTHUR BLVD., SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: T-1 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE VICINITY MAP: DRIVING DIRECTIONS: APPLICABLE CODES · · · · · · · · SI5 201 E MACARTHUR BLVD., SANTA ANA, CA 92707 · · PROJECT SUMMARY: · PROJECT TYPE: PROPERTY MANAGEMENT Bldg #101121870 APPROVALS: PLNG - C. Santana BLDG - CSG POLICE - B. Martin 201 E MacArthur Blvd3/13/2025 ABBREVIATIONS & SYMBOLS 2 GENERAL NOTES & SPECIFICATIONS 1 ABBREVIATIONS, SYMBOLS, GENERAL NOTES & SPECIFICATIONS NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: T-2 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 201 E MacArthur Blvd3/13/2025 SITE PLAN NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: A-1 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 1SITE PLAN E MACARTHUR BLVD MA C A R T H U R P I FIRST AMERICAN WAY APN: 411-072-08 ZONING: SPECIFIC DEVELOPMENT (SP43) 201 E MacArthur Blvd3/13/2025 ENLARGED SITE PLAN NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: A-2 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 1ENLARGED SITE PLAN 201 E MacArthur Blvd3/13/2025 EXISTING EQUIPMENT LAYOUT NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: A-3 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 1EXISTING EQUIPMENT LAYOUT AT ROOF DECK 201 E MacArthur Blvd3/13/2025 EXISTING AND NEW OPENING ELEVATIONS NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: A-4 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 24 1EXISTING WEST ACCESS OPENING ELEVATION NEW WEST ACCESS OPENING ELEVATION 3 EXISTING EAST ACCESS OPENING ELEVATION NEW EAST ACCESS OPENING ELEVATION 201 E MacArthur Blvd3/13/2025 ELEVATIONS NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: A-5 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 2 EXISTING EAST ELEVATION 1 NEW EAST ELEVATION 201 E MacArthur Blvd3/13/2025 ELEVATIONS NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: A-6 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 2 EXISTING WEST ELEVATION 1 NEW WEST ELEVATION 201 E MacArthur Blvd3/13/2025 STRUCTURAL STEEL FIELD WELDING NO.DATE:DESCRIPTION:BY: SHEET NUMBER: SHEET TITLE: SITE INFORMATION: SEAL: 201 3/4 E. MACARTHUR BLVD., #WCC01, SANTA ANA, CA 92707 DOUBLE TREE HOTEL SC071 LA02834A PLANS PREPARED BY: CONSULTING GROUP: S-1 A NUWAVE COMPANY SIGNAL HILL, CALIFORNIA 90755 1875 CORONADO AVE 2 3 WELDING DETAILS 1 5 6 4 8 9 7 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USEDNOT USED 201 E MacArthur Blvd3/13/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 201 E MacArthur Blvd3/13/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 201 E MacArthur Blvd3/13/2025 1875 Coronado Ave. Signal Hill, CA 90755 Rooftop Screen Modification Structural Calculations Pr oj e c t : T - M o b i le Pr o p e r t y m an ag e m e n t S it e n u m b e r : L A 0 2 8 3 4 A S it e n am e : Do u b le t r e e H o t e l S C 0 7 1 A d d r e s s: 2 0 1 ¾ E . M ac A r t h u r B lv d WWC C 0 1 S an t a A n a, C A 9 2 7 0 7 Da t e : 1 0 / 1 8 / 2 0 2 4 THESE CALCULATIONS ARE THE SOLE PROPERTY OF INTELOCITY, AND MAY NOT BE USED WITHOUT WRITTEN CONSENT. THE BUILDING OFFICIALS SHALL NOT ACCEPT THESE CALCULATIONS UNLESS WET STAMPED AND SIGNED BY THE ENGINEER OF RECORD. 201 E MacArthur Blvd3/13/2025 Description of the project: Existing rooftop screen framing modification at elevation 100’-0”. No footprint and no height increasing. Design Codes: 2022 California Building Code with local amendment. Design Criteria: Seismic: Risk Category II, Site D, Ss=1.46, S1=0.49 Sms=1.72, Sm1=1.17, Sds=1.14, Sd1=0.78 Wind: Exposure C, 95 mph. Appurtenances: See Next Pages References: n/a Passing Rate: 19.9 % Steel tubing screen framing Disclosure: Please be advised that the evaluation and recommendations made were based on minimum design loads per current building codes without full as-built plans and without on-site intrusive investigation and verifications. With this inherent limitation, the design and evaluation were done in accordance with generally accepted engineering principles and practice. The engineer of record shall be notified immediately when discrepancy occurs between the actual on-site condition and this report and/or drawings for remedial solutions. 1/10 201 E MacArthur Blvd3/13/2025 24NEW WEST ACCESS OPENING ELEVATION NEW EAST ACCESS OPENING ELEVATION 2/10 201 E MacArthur Blvd3/13/2025 3/10 201 E MacArthur Blvd3/13/2025 4/10 201 E MacArthur Blvd3/13/2025 ASCE Hazards Report Address: 4 E MacArthur Blvd Santa Ana, California 92707 Standard:ASCE/SEI 7-22 Latitude:33.699871 Risk Category:II Longitude:-117.86756 Soil Class:Default Elevation:36.32257420038008 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 102 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 133 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Fri Oct 18 2024 Page 1 of 5https://ascehazardtool.org/Fri Oct 18 2024 5/10 201 E MacArthur Blvd3/13/2025 PGA M : 0.65 SMS : 1.72 SM1 : 1.17 SDS : 1.14 SD1 : 0.78 T L : 8 SS : 1.46 S1 : 0.49 VS30 : 260 Seismic Design Category:D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 3 of 5https://ascehazardtool.org/Fri Oct 18 2024 6/10 201 E MacArthur Blvd3/13/2025 Seismic Calculation for Roof Top Screening Site Coordination = 33.699871, -117.86756 Soil Site Class =D Risk Category =II From Spectrum Data: SMS =1.72 g SDS = 2/3 SMS =1.147 g SM1 =1.17 g SD1 = 2/3 SM1 =0.780 g Seismic Design Category =D r 1.0 Seismic Design Force : Rp =2.5 ap =1.0 Ip =1.0 z/h =1.0 W p =95.0 lbs Screen Unit DL / ft Fp = [0.4 ap SDS W p / (Rp/Ip)] x (1+2(z/h)) =52.29 lbs Fp,MAX = 1.6 SDS Ip W p Fp,MIN = 0.3 SDS Ip W p =174.29 lbs =32.68 lbs Therefore Fp =52.29 lbs Seismic Load Effects E : E =rFp ± 0.2 SDS D =52.29 lbs ±21.79 lbs (Lateral) (Vertical) Seismic LRFD Coefficient = 0.55 Over strength factor=2.50 E mh = W Eh =130.72 lbs ASD design coefficient =0.39 7/10 201 E MacArthur Blvd3/13/2025 Screen Wind Loads for Member and Anchroage Design Basic Wind Speed =95 mph Exposure =C Category =II Mean Roof Height (h) =100 ft Screen Unit Dimension : W =12.0 in unit width per foot H =228.0 in screen ht Af Projection Area =19.0 s.f. Apply "Design Wind Loads on Other Structures" FWind =q h (G C f ) A f q h =velocity pressure evaluated at height z of the centroid og area of Af =0.00256 Kz Kzt Kd Ke V2 (psf) Kz =1.26 Kzt = (1 + K1 K2 K3)2 =1.0 Kd =0.85 Ke =1.00 qh =psf G Cf =1.9 ASD factor = 0.6 f wind (LRFD) =47.0 psf f wind (ASD) =28.2 psf Final Fw (LRFD) =893.3 lbs Final Fw (ASD) =536.0 lbs Optional with reduced screen / building factor Wide Face Wide face to bldg width ' t/b ' = 0.1 Reduction factor = 1.9 - [(1.9-1.0) x ' t/b ']= 1.81 Final Fw (LRFD) =44.8 psf Final Fw (ASD) =26.9 psf Narrow Face Narrow face to bldg width ' t/b ' = 0.2 Reduction factor = 1.9 - [(1.9-1.0) x ' t/b ']= 1.72 Final Fw (LRFD) =42.6 lbs Final Fw (ASD) =25.5 lbs 8/10 201 E MacArthur Blvd3/13/2025 Steel Beam LIC# : KW-06019495, Build:20.23.11.13 Reliant Land Services (c) ENERCALC INC 1983-2023 DESCRIPTION:CHECK (N) TS5X5X1/4 DOOR JAMB POST Project File: Nuwave T-Mobile_2022 CBC.ec6 Project Title: Engineer: CODE REFERENCES Material Properties Analysis Method : ksi Bending Axis :Major Axis Bending Completely Unbraced Load Resistance Factor Design Fy : Steel Yield :45.0 ksi Beam Bracing :E: Modulus :29,000.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight NOT internally calculated and added Uniform Load : D = 0.010, W = 0.0470 ksf, Tributary Width = 3.0 ft, (SCREEN WIND) Point Load : W = 0.70 k @ 5.0 ft, (HZ GIRT) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.199 : 1 Load Combination +1.20D+W Span # where maximum occurs Span # 1 1.235 k Mn * Phi : Allowable 19.879 k-ft Vn * Phi : Allowable HSS5x5x3/16Section used for this span Span # where maximum occurs Location of maximum on span Span # 1 Load Combination +1.20D+W 37.868 k Section used for this span HSS5x5x3/16 Mu : Applied Maximum Shear Stress Ratio =0.033 : 1 0.000 ft 3.963 k-ft Vu : Applied 0 <360 1067 Ratio =0 <180 Maximum Deflection Max Downward Transient Deflection 0.156 in 766Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.112 in Ratio =>=180 Max Upward Total Deflection 0 in Span: 1 : W Only n/a Span: 1 : +D+0.60W n/a .Maximum Forces & Stresses for Load Combinations Span # Max Stress Ratios M V max Mu -max Mu +Rm VnxMu Max Phi*Mnx Cb VuMaxMnx Phi*VnxSegment Length +1.40D Dsgn. L = 10.00 ft 1 0.026 0.006 0.53 0.53 22.09 19.88 1.14 1.00 0.21 42.08 37.87 1 0.023 0.005 0.45 0.45 22.09 19.88 1.14 1.00 0.18 42.08 37.87 1 0.111 0.019 2.21 2.21 22.09 19.88 1.20 1.00 0.71 42.08 37.87 1 0.199 0.033 3.96 3.96 22.09 19.88 1.21 1.00 1.24 42.08 37.87 1 0.194 0.031 3.85 3.85 22.09 19.88 1.21 1.00 1.19 42.08 37.87 1 0.017 0.004 0.34 0.34 22.09 19.88 1.14 1.00 0.14 42.08 37.87 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.1565 5.029 0.0000 0.000 . 9/10 201 E MacArthur Blvd3/13/2025 Steel Beam LIC# : KW-06019495, Build:20.23.11.13 Reliant Land Services (c) ENERCALC INC 1983-2023 DESCRIPTION:CHECK (N) TS5X5X1/4 DOOR JAMB POST Project File: Nuwave T-Mobile_2022 CBC.ec6 Project Title: Engineer: Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.055 1.055 Max Upward from Load Combinations 0.783 0.783 Max Upward from Load Cases 1.055 1.055 D Only 0.150 0.150 +D+0.60W 0.783 0.783 +D+0.450W 0.625 0.625 +0.60D+0.60W 0.723 0.723 +0.60D 0.090 0.090 W Only 1.055 1.055 10/10 201 E MacArthur Blvd3/13/2025