Loading...
HomeMy WebLinkAbout901 E Myrtle St Unit# 2 - Plan2% W G 5% 5% 5% 5% 2% 2% 2% 5% 2% 2% 5% 5% 2% 2% 2% 5%5% 5% 5% 2% 2% 2% 2% W G 5% 5% 5% 5% 2% 2% 2% 5% 2% 2% 5% 5% 2% 2% 2% G W 2% 2% 2% 5% 2% 5% 5% 5%2% 2%2% 1 (N) ELECTRICAL SUB-PANEL 225AMPS FOR ADU 2 PERIMETER FENCE / BLOCK WALL 4 5 6 7 8 9 10 11 12 (E) WALK WAY LANDSCAPE (E) TREE (N) CONSUMER TANK WITH/ HEAT PUMP (E) GATE 17 (N) HEAT PUMP UNIT ON 3''. THK CONCRETE PAD (E) MAIN HOUSE ELECTRICAL PANEL V.I.F (E) WATER METER (N) ELECTRICAL METER FOR ADU (E) GAS METER V.I.F 3 ROOF LINE ABOVE (N) LANDING 18 (N) GAS METER (N) WATER METER (1" MINIMUM PER CITY REQUIREMENTS) (E) A/C UNIT V.I.F (E) POST 13 14 15 16 19 (N) 6X6 POST 20 21 1-HR FIRE RESISTANT EAVE PROJECTION SEE DETAIL 05/AD.20 & 01/AD.20 PROVIDE 2-2X FULL HEIGHT FIRE BLOCKING FROM TOP PLATE TO UNDERSIDE OF EXISTING ROOF SHEATHING, NO VENT HOLE ALLOWED. 22 1-HR FIRE RATED WALL, SEE SHEET 01/AD20 FOR DETAIL. 23 (N) DRIVE WAY 23 ELECTRICAL VEHICLE CHARGING STATION LOCATION. 208/240-VOLT BRANCH CIRCUIT (40 AMP) 1 DRAINAGE DIRECTION AND SLOPE PROPERTY LINE CORNER POINTS AND ELEVATION DATUM #KEYNOTE CALLOUTS EXISTING TO BE REMAINED AND NEW CONSTRUCTION EXISTING TO BE DEMOLISHED F.S.D F.S.L FIRE SEPARATION DISTANCE FIRE SEPARATION LINE (IMAGINARY PROPERTY LINE) 1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE- WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE AS- BUILT INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS REQUIRED. 2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, PPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. 5. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES. 6. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. 7. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. 1 1. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 2. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 3. PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. 4. FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. 5. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND AMENDMENTS. 6. A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. 7. WATER HEATER MUST BE STRAPPED TO WALL. 8. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 9. CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT THERE IS NO TRACEOF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. 10. SHEARWALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARD LISTED IN CH.6 & CH.7 CRC 11. UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. 12. UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE TV. AND TELEPHONE 13. ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED 14. BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED RECEPTACLE OUTLETS. 15. PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT OPENABLE WINDOW. 16. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC 17. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. 18. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. 19. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. 20. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. 21. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND THE DESIGNER/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. 22. VERIFY WITH AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. 23. WHEN SOLAR PANEL IS REQUIRED, SOLAR PLANS SHALL BE REVIEWED AND APPROVED BY BUILDING DIVISION PRIOR TO ROOF SHEATHING INSPECTION. 24. FOR EACH DWELLING UNIT, INSTALL A LISTED RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT (40 AMP) COMPLIANCE WITH SECTION 4.106.4.1 25. THE SERVICE PANEL OR SUB-PANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE". 1 THE PROPOSED PROJECT IS A NEW 791 SF DETACHED ADU, ATTACHED 302 SF 1-CAR GARAGE AND CONSIST OF: • 2 BEDROOMS, 2 BATHROOMS. • KITCHEN, DINING, LIVING ROOM. • 52 SF PATIO, 19 SF LANDING. • NEW CENTRAL AC, NEW HEATPUMP WATER HEATER, NEW AIR HANDLERS. • DUAL-GANG ELEC PANEL METER AND SUB-PANEL. THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE . SANTA ANA, AMENDMENTS AND MUNICIPAL CODE. LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92701 1 THE DESIGN OF THE ACCESSORY DWELLING UNIT SHALL BE ARCHITECTURALLY COMPATIBLE WITH THE MAIN DWELLING UNIT, WITH ALL DESIGN. THE DESIGN, ROOF PITCH, DEPTH OF EAVE, COLOR, MATERIAL AND TEXTURE OF THE ROOF SHALL BE SUBSTANTIALLY THE SAME AS THE MAIN DWELLING UNIT. PL 56.58' PL 1 0 0 . 0 2 ' PL 6 4 . 8 7 ' PL 1 4 .28' PL 35. 4 6 ' PL 42.84' (E) 42'-11 1/2" (E ) 25 ' - 9 " (E ) F R O N T S E T B A C K 22 ' - 5 1 / 2 " (E ) S E T B A C K 4' - 1 0 " (E) 32'-4" 27 ' - 0 " (E ) 27 ' - 0 " (E) S E T B A C K 5'-8 1/2" (E) 13'-8" (E) 5'-0" (E ) 3' - 0 " (E) 23'-8" (E) 21'-0" (E ) 19 ' - 1 " (E) 20'-1" (E) 2- CAR GARAGE 420 SF SINGLE FAMILY RESIDENCE 1044 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 (E) PROCH STREET CURB & GUTTER CENTERLINE OF STREET CENTERLINE OF STREET (E ) 22 ' - 6 " (E) POWER POLE 1 2 2 2 8 4 4 4 8 9 9 9 9 3 15 16 7 5 2 9 9 9 9 4 21 2 2 9 (E ) 1' - 0 " (E) 18'-8" (E) 4'-9 1/2" (E) 1'-0" (E) 1'-0" (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) SET BACK 5'-9 1/2" (E ) 3' - 1 0 " (E) 31'-4" (E ) 1' - 0 " (E ) 1' - 0 " (E) 19'-3 1/2" (E ) 22 ' - 9 " (E ) 4' - 0 " (E ) 3' - 0 " (E ) 6" TO C E N T E R L I N E 30 ' - 0 " (E ) 20 ' - 0 " E MYRTLE ST S S T A N D A R D A V E ALLEY PL 56.58' PL 1 0 0 . 0 2 ' PL 64 . 87 ' PL 14.28' PL 3 5 . 46' PL 42.84' (E ) 1' - 0 " (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" (E ) T O C E NT E R L I N E 30 ' - 0 " (E) 42'-11 1/2" (E ) 25 ' - 9 " (E ) F R O N T S E T B A C K 22 ' - 5 1 / 2 " (E ) S E T B A CK 4' - 1 0 " (E) 2- CAR GARAGE 420 SF SINGLE FAMILY RESIDENCE 1044 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 (E) 1'-0" (E) 1'-0" (E ) 1' - 0 " TO C E N T E RL I N E 10 ' - 0 " (E) SE TBA C K 5'-8 1/ 2" (E) 13'-8" (E) TOCENTER LINE 30'-0" (E) PROCH STREET CURB & GUTTER CENTERLINE OF STREET CENTERLINE OF STREET (E ) 4' - 0 " (E ) 3' - 0 " (E ) 6" (E ) 22 ' - 6 " (E) 5'-0" (E ) 3' - 0 " (E) 19'-3 1/2" (E) 23'-8" (E) 4'-0" (E) 3'-0" (E) 6" (E) POWER POLE (E ) 19 ' - 1 " (E) 20'-1" 1 2 2 2 8 44 4 8 9 9 9 9 3 15 16 7 5 2 9 9 9 1'-0" 1' - 0 " 1' - 0 " 1'-0" 1' - 0 " DI S T A N C E 6' - 0 " F. S . D 3' - 0 " F. S . D 3' - 0 " DISTANCE 5'-1" (N) ADU 1-CAR GARAGE 302 SF 20 20 20 4 F.S.L 17'-4 1/2"9'-10 1/2" 10'-2" (E) SETBACK 18'-0" (N) DETACHED ADU - UNIT 2 791 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 (E) SETBACK 5'-9 1/2" 21 22 22 F. S . D 3' - 0 " F. S . D 3' - 0 " 22 2 AD.20 2 AD.20 14 (E) 1'-0" (E) 18'-0" (E) 4'-9 1/2" 9 9 23 9 3' - 1 0 " 51'-7" 41 ' - 0 " 22 9 2 AD.20 19 19 17 13 MIN. 2'-0" 18 23 35 ' - 1 0 " 10 10 11 12 (E ) 1' - 0 " DI S T A N C E 6' - 0 " (N) WALKWAY CLR 12'-0"9 E MYRTLE ST S S T A N D A R D A V E 4' - 0 " ADU SETBACK 5'-0" 16'-4 1/2"1'-0" 1'-0" 4'-0" ALLEY 21 ' - 5 " 20 5 AD.20 1 9 E JURISDICTION HAVING AUTHORITY: CITY OF SANTA ANA, CA 92701 LEGAL DESCRIPTION: N TRACT 2482 BLK, LOT 72 ASSESSORS PARCEL NO. APN: 404-011-11 IN FLOOD ZONE FEMA SHFA'S: FLOOD ZONE X CONSTRUCTION TYPE: V-B ZONING: R1 (SINGLE FAMILY RESIDENTIAL) OCCUPANCY GROUP: R3/U SPRINKLERS: EXISTING: NO ADU: NO (E) MAINHOUSE MAX HEIGHT: 15 FT ADU MAX. HEIGHT: 14 FT (E) REQUIRED SETBACKS: FRONT: 4 FT SIDE: 4 FT REAR: 4 FT DISTANCE TO (E) STRUCT: 6 FT LOT SIZE: 6,554 SF EXISTING: (E) MAIN HOUSE LIVING AREA: 1,044 SF (E) GARAGE: 420 SF EXISTING TOTAL: 1,464 SF NEW CONSTRUCTION (N) DETACHED ADU: 791 SF (N) GARAGE: 302 SF (N) COVER PORCH: 52 SF (N) LANDING: 19 SF NEW TOTAL: 1,164 SF MAXIMUM LOT COVERAGE: 35% OVERALL LOT COVERAGE: (1,164 SF + 1,464 SF) / 6,554 SF = 40,1% LOT COVERAGE AND USE INTENSITY MAXIMUM ESTABLISHED IN ZONING DISTRICT MAY BE EXCEEDED TO PERMIT AN ADU UP TO EIGHT HUNDRED (800) SQUARE FEET IN SIZE PARKING REQUIREMENT NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN ACCORDANCE WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN ACCESSORY DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING DISTANCE OF PUBLIC TRANSIT. TOTAL PARKING REQUIRED (E) MAIN HOUSE: 2 STALLS (N) ADU 1 STALL (SEE EXCEPTION ABV.) TOTAL: 3 STALLS PROJECT LOCATION IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATE DELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK 03/11/2024 2ND PLAN CHECK2 A.00 SITE PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 SHEET INDEX SITE PLAN KEYNOTES GENERAL NOTES PROJECT DATA ARCHITECTURAL A.04 EXISTING - FLOOR PLAN A.05 PROPOSED ADU FLOOR & ROOF PLAN A.06 PROPOSED ADU SECTIONS & ELEVATIONS AD.10 ARCHITECTURAL DETAILS AD.20 ARCHITECTURAL DETAILS D.01 DRAINAGE PLAN T24.1 TITLE 24 T24.2 TITLE 24 (CONT.) T24.3 TITLE 24 (CONT.) STRUCTURAL S-0.10 GENERAL NOTES & REQUIREMENTS S-0.11 GENERAL NOTES & REQUIREMENTS S-1.0 FOUNDATION PLAN S-2.0 FRAMING PLAN SD1.0 FOUNDATION DETAILS SD2.0 STRUCTURAL DETAILS WSWH1 STRONG WALL WSWH ANCHORAGE DETAIL WSWH 1.1 STRONG WALL WSWH ANCHORAGE ALTERNATE DETAIL WSWH2 STRONG WALL WSWH FRAMING DETAIL APPLICABLE CODE SPECIAL NOTES 1" = 10'-0" 1EXISTING SITE PLAN 1" = 10'-0" 2PROPOSED SITE PLAN SYMBOL LEGEND CONSTRUCTION NOTES VINCITY MAP DEFERRED SUBMITTALS SCOPE OF WORK 2.41 KW PER T24 PV SYSTEM WILL BE UNDER A SEPARATE PERMIT FOR ADU THE MAIN ELECTRICAL SERVICE PANEL RATING OF 225 AMPS. THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BURSAR A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". SOLAR PV SYSTEM MUST BE APPROVED REQ BUILDING DIVISION PRIOR ROOF SHEATHING INSPECTION. 2.15 kW PHOTOVOLTAIC SYSTEM WILL BE SUBMITTED UNDER A SEPARATE PERMIT AND SHALL BE ISSUED PRIOR TO BUILDING FRAME INSPECTION REQUEST (E) BLOCK WALL TO BE DEMOLISHED NOTE: THE APPLICANT / PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND / OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT. 1 1 1 2 A.01 CAL GREEN CODE A.02 CAL GREEN CODE A.03 GENERAL DETAILS A.00 SITE PLAN A.08 ROOM FINISH & DOOR/WINDOW SCHEDULE & INTERIOR DETAILS A.07 PROPOSED ADU ELECTRICAL PLAN S-0.20 TYPICAL DETAILS S-0.12 SOIL REPORT S-0.13 SOIL REPORT S-0.14 SOIL REPORT & SOIL REPORT BLDG# 101118160 APPROVALS PLNG - ASevilla BLDG - GHuang POLICE - BMartin 901 E Myrtle St Unit# 2 - 1011181606/27/2024 1. WINDOW MANUFACTURER AND INSTALLER SHALL INSURE THAT ALL WINDOWS MEET OR EXCEED ALL EGRESS REQUIREMENTS OF CRC R310 & R312 2. ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE INSTALLED PER AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION AAMA 2400=02 RECOMMENDATIONS "STANDARD PRACTICE FOR INSTALLATION OF WINDOWS WITH INTEGRAL MOUNTING FLANGES IN STUD FRAME CONSTRUCTION". 3. INSTALL AN ISOLATION MEMBRANE BELOW THE THRESHOLD OF ALL SLIDING GLASS DOORS THAT REST ON A CONCRETE SLAB. 4. ALL SEALANT SHALL BE OF HIGH QUALITY AND REVIEWED OFR COMPATIBILITY WITH ASPHALTIC MEMBRANES AND FLASHING MATERIAL. 44 " M A X I M U M 24 " M I N . 20" MINNIMUM F.F. > 72" ABV. FINISH GRADE. 24 " M I N I M U M @ 44 " M A X I M U M 20" MINNIMUM F.F. > 72" ABV. FINISH GRADE. 24 " M I N I M U M @ 5.7 S.F MINIMUM 24 " M I N . 5. 7 S . F M I N I M U M 1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. 2. MIN. SET CLEAR HEIGHT OF 24 INCHES. 3. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE FLOOR. EMERGENCY EGRESS WINDOW AND DOOR NOTE AGING IN PLACE R327.1.3 INTERIOR DOORS EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN 32 INCHES (812.8 MM), MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED POSITION; OR, IN THE CASE OF A TWOOR THREE-STORY SINGLE FAMILY DWELLING, ON THE SECOND OR THIRD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. R327.1.4 DOORBELL BUTTONS DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. R327.1.1 REINFORCEMENT FOR GRAB BARS AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 39 1/4 INCHES (997 MM) ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. EXCEPTIONS: 1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PREFABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORYINSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. 3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. 4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. 5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS: ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES (1219.2 MM) MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. EXCEPTIONS: 1. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. 2. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW,IS LESS THAN 15 INCHES (381 MM) 1. ALL DOORS AND WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE. 2. ALL EXTERIOR DOORS & WINDOWS SHALL BE WEATHER TIED AND PROVIDE WITH INSECT SCREEN-METAL. DOORS & WINDOWS SHALL BE IN COMPLIANCE WITH ANSI. STD. A13 OR A1342. 3. THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE W ITH THE ENERGY CALCULATIONS. 4. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. 5. ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, LASER-ETCHED, OR EMBOSSED PER CRC 2406.3. 6. GLAZING AND INSULATION SHALL CONFORM TO THE STATE ENERGY INSULATION STANDARD. 7. DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE) 8. GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR 9. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY SURFACE AVAILABLE FOR USE BY THE PUBLIC SHALL BE CAPABLE OF BEING LOCKING SECURELY. MOVEABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME. 10. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING DOOR. SUCH VIEW MAY BE POVIDED BY A DOOR VIEW, A VIEW PORT, WINDOW, OR OTHER OPENING. 11. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUM THROW OF 1 INCH AND AN EMBEDMENT OF NOT LESS THAN 5/8 INCH. 12. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORS SHALL BE EQUIPPED WITH A DEAD BOLT. 13. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM THE OUTSIDE WHEN THE DOOR IS CLOSED. 14. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/2" THICK. 15. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/4" THICK. 16. ANY GLASS WHICH IS LOCATED WITHIN 40 INCHES OF THE BLOCKING DEVICE ON A DOOR SHALL BE FULLY TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR GRILLS. 17. IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM DOOR/W INDOW ROUGH OPENING DIMENSIONS WITH THE MANUFACTURE/SUPPLIER PRIOR TO BEGIN CONSTRUCTION 18. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. (R309.4) 19. EMERGENCY EGRESS: A. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. B. MIN. SET CLEAR HEIGHT OF 24 INCHES. C. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE FLOOR. ATTIC AIR HANDLER 20' MAX. 30" MIN. MIN. 30X30" WORKING PLATFORM SECURED IN PLACE 22x30" MIN. ATTIC ACCESS MIN. 24" WIDE SOLID FLOORING FROM ACCESS OPENING TO FURNACE WORKING PLATFORM LIGHT SWITCH 30 " M I N . 30 " M I N . ELECTRIC OUTLET AND LIGHT FIXTURE AIR HANDLER DISCONNECT AND ELECTRICAL OUT LET IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM A.03 GENERAL DETAILS (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 DOOR/ WINDOW NOTES ATTIC AIR HANDLER REQUIREMENTS WATER HEATER REQUIREMENTS 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Refrigerator A.04 3 A. 0 4 4 A. 0 4 5 A.04 6 (E) 1' - 0 " (E) 1'-0" (E) 1'-0" (E) 1' - 0 " (E) 1' - 0 " (E) 1'-0" (E) 2' - 0 " (E) 4' - 0 " (E) ROOF 4: 1 2 4: 1 2 (E) PORCH (E) WALL LINE BELOW (E) WALL LINE BELOW (E ) W A L L L I N E B E L O W (E ) W A L L L I N E B E L O W (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E) (E) A.04 3 A. 0 4 4 A. 0 4 5 A.04 6 (E) BEDROOM#2(E) BEDROOM#1 (E) BEDROOM#3 (E) POST (E) PORCH (E) KITCHEN (E) LIVING (E) DINING (E) CLOSET (E) BATH (E) (E) MAIN HOUSE 1ST F.F 1' -6" (E) MAIN HOUSE APPX. HEIGHT 15' -0" (E) MAIN HOUSE TOP PL. 10' -6" (E) 1'-0" (E) 1'-0" (E)(E)(E)(E)(E) 4: 1 2 (E ) 9' - 0 " (E ) 1' - 6 " (E ) M A I N H O U S E A P P X . H E I G H T 15 ' - 0 " (E) ROOF (E) STUCCO WALL & PAINT (E) MAIN HOUSE 1ST F.F 1' -6" (E) MAIN HOUSE APPX. HEIGHT 15' -0" (E) MAIN HOUSE TOP PL. 10' -6" 4:12 4:12 (E) (E) (E ) 9' - 0 " (E ) 1' - 6 " (E ) M A I N H O U S E A P P X . H E I G H T 15 ' - 0 " (E) STUCCO WALL & PAINT (E) 1'-0" (E) 1'-0" (E) MAIN HOUSE 1ST F.F 1' -6" (E) MAIN HOUSE APPX. HEIGHT 15' -0" (E) MAIN HOUSE TOP PL. 10' -6" 4:12 4:12 (E) (E ) 1' - 6 " (E ) 9' - 0 " (E ) M A I N H O U S E A P P X . H E I G H T 15 ' - 0 " (E) STUCCO WALL & PAINT (E) 1'-0" (E) 1'-0" (E) MAIN HOUSE 1ST F.F 1' -6" (E) MAIN HOUSE APPX. HEIGHT 15' -0" (E) MAIN HOUSE TOP PL. 10' -6" (E) 1'-0" (E) 1'-0" (E) 1'-0" (E ) 9' - 0 " (E ) 1' - 6 " (E ) B U I L D I N G A P P X . H E I G H T 15 ' - 0 " (E)(E) (E) ROOF (E)(E)(E) 4: 1 2 (E) STUCCO WALL & PAINT (E) BRICK WALL (E) STUCCO WALL & PAINT (E) POST IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM A.04 EXISTING - FLOOR PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 1/4" = 1'-0"2EXISTING - ROOF PLAN 1/4" = 1'-0"1EXISTING - FLOOR PLAN 1/4" = 1'-0"3EXISTING NORTH ELEVATION 1/4" = 1'-0"4EXISTING EAST ELEVATION 1/4" = 1'-0"5EXISTING WEST ELEVATION 1/4" = 1'-0"6EXISTING SOUTH ELEVATION NOTE: ALL EXISTING DIMENSIONS IS FOR REFERENCE ONLY AND TO BE VERIFIED IN FIELD BY THE CONTRACTOR 901 E Myrtle St Unit# 2 - 1011181606/27/2024 AT T I C HP W/H RE F . DW DW AT T I C HP 1. VERIFY ALL APPLIANCE EQUIPMENT AND FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO CASEWORK FABRICATION INSTALLATION. 2. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & PAINT EXPOSED GYP. BD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BD. 3. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NON- ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. 6. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING FINISH. 7. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE HARD WIRED WITH BATTERY BACK-UP AND LOCATED (1) IN EACH BEDROOM, HALLWAYS OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM SOUND MUST BE AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER MFGR. LISTED REQUIREMENTS. 8. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING ROOMS PER CHAPTER 3 CRC. 9. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE DUCTED TO THE EXTERIOR OF THE BUILDING 10. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD REQUIREMENTS. 11. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. 12. PROVIDE TWO LAYERS OF GRADE D OR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE SHEATHING AT EXTERIOR WALLS. 13. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE OF 3½ INCHES SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) 14. ACCESS TO ATTIC FURNACE MUST BE WITHIN 20' OF UNIT AND SHALL HAVE A CONTINUOUS SOLID WALKWAY AT LEAST 24" WIDE. A SWITCH CONTROL IS ALSO REQUIRED (CMC 304.4.1) 15. DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET (4267 MM), INCLUDING TWO 90 DEGREE (1.57 RAD) ELBOWS. A LENGTH OF 2 FEET (610 MM) SHALL BE DEDUCTED FOR EACH 90 DEGREE (1.57 RAD) ELBOW IN EXCESS OF TWO. 16. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 17. WATER HEATER MUST BE STRAPPED TO WALL. 18. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. 19. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC 20. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. 21. ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(N)1A-D) A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. D. A GAS SUPPLY LINE WITH AVAILABLE CAPACITY FOR NOT LESS THAN A 200,000 BTU/HR SYSTEM. 22. ADU FINISH FLOOR ELEVATION IS NOT NOT LOWER THAN THE FINISH FLOOR OF THE MAIN HOUSE AND HIGHER 1' MINIMUM THAN BASE FLOOD ELEVATION. EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF) (N) 2X4 INTERIOR WALL (N) 2X4 EXTERIOR WALL / INFILL WITH INSULATION PER T-24 1-HOUR FIRE RATED WALL EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL IAQ FAN: ( MIN 46 CFM PER T-24 ) PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE HB 3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ BATTERY BACK UP CD 22X30 ATTIC ACCESS HEATPUMP + AIR HANDLER HEATPUMP UNIT ON PAD 3" MIN. LAUNDRY DRYER EXHAUST CEILING AIR DIFFUSER ELECTRICAL PANEL/METER PER KEYNOTE CONSUMER TANK WITH/ HEAT PUMP DOOR TYPE SEE A.08 FOR SCHEDULE WINDOW TYPE SEE A.08 FOR SCHEDULE KEY NOTE FLOOR DEPRESSION1.5'' XX XX XX WHOLE HOUSE FAN: 1186.5 CFM PER T-24 E ELECTRICAL VEHICLE CHARGING STATION LOCATION. 208/240-VOLT BRANCH CIRCUIT (40 AMP) 1 1 2 3 4 5 7 9 EXHAUST FAN FOR BATHROOM SHALL BE MINIMUM 50 CFM AND CONTAIN HUMIDISTAT (EXHAUST THROUGH ROOF). 10 EXHAUST FAN ABOVE KITCHEN GAS RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF) 11 8 (N) DUAL-GANG ELECT. METER BOX (N) ELECTRICAL SUB-PANEL 225 AMPS (N) LANDING. 1 1/2" BELOW THRESHOLD. MINIMUM 36" IN DEPTH.MIN. 2% SLOPE AWAY FROM BUILDING. (N) 22X30 ATTIC ACCESS 2'' SHOWER CURB MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL/ROOF) 6 (N) HEAT PUMP UNIT ON 3" THIK. CONCRETE PAD (N) 6X6 POST TEMPERED GLASS 12 (N) CONSUMER TANK WITH/ HEAT PUMP, DETAIL ON SHEET A.03 13 APPROVED PRE-FABRICATED SHOWER ENCLOSURES WALL PANELS WITH FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS. SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET 14 FUTURE INSTALLED FLOOR MOUNTED FOLDABLE GRAB BAR 15 2X8 BACKING FOR FUTURE GRAB BAR INSTALLATION 16 32'' MIN. CLR. INTERIOR DOOR SEE NOTE ON ''AGING-IN-PLACE'' 17 18 OBSCURED,TEMPERED GLASS 19 1HR FIRE RATED WALL, UPNPROTECTED OPENING MAX 25% WALL AREA, SEE CALCULATION ON ELEV. 01/A.06,02/A.06 20 8'' GARAGE CURB, SEE STRUCTURAL DWG 21 DOOR BETWEEN GARAGE AND LIVING AREA SHALL BE 20 MIN. RATED 1-3/8" SOLID CORE WITH CLOSER AND LATCHING HARDWARE, SMOKE SEAL @ JAMB, HEAD @ METAL THRESHOLD 5/8" TYPE "X" GYPSUM BOARD ALL WALLS, CEILINGS, BEAMS, POSTS AND COLUMNS, SMOOTH FINISH TYPICAL AT GARAGE 1.ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. 2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. 3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT. 4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. 5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER TH AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR0IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER. ATTIC AREA: 800 SF USE BALANCE METHOD : 1/300 NET VENT AREA REQUIRE : 800/300 x 144 SQ.IN. = 384 SQ.IN FOR WHOLE HOUSE VENT: 1186.5 CFM-227 SQ.IN VENT NFA IS REQUIRED ( 144 SQFT PER 750 CFM) TOTAL VENT AREA REQUIRED: 611 SQ.IN NOTE: MAX 50% ON UPPER ROOF AREA LOW: USE 3 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) = 216 SQ.IN (1/3 LOW AREA OF ROOF) HIGHT: USE 3 UNITS O'HAGIN VENT (72 SQ.IN/UNIT)= 216 SQ.IN (1/3 HEIGHT AREA OF ROOF) + 10 FT RIGDE VENT (18 SQ.IN/FOOT)= 180 SQ.IN TOTAL = 612 SQ.IN 4'-9 1/2"4'-9 1/2" 9'-7 1/2" 2' - 0 " 3'-1" 11 ' - 4 1 / 2 " 2' - 4 1 / 2 " 3' - 8 " 3' - 5 " 20 ' - 1 0 " 15'-1 1/2"8'-10"5'-4 1/2" 5' - 7 1 / 2 " 4' - 7 " 3'-10"8'-4"5'-4 1/2" B A.06 B A.06 GARAGE 15"15" 17 " 17 " 21'-1 1/2"12'-8" 5' - 8 " 17 ' - 1 1 " 8'-0" 5' - 0 " 5'-0" 14 ' - 9 " 51'-4" A.06 2 A. 0 6 3 A.06 1 A. 0 6 4 8' - 8 1 / 2 " 11'-9 1/2" 3' - 6 " 5' - 3 " 11 ' - 0 " 8'-11 1/2" 5'-0" A A.06 A A.06 SD CDSD CDSD SD 30" 3'-0" 6' - 0 " 1. 5 ' ' 1.5'' 1 2 3 5 3 3 3 4 6 5' - 0 " 20'-9" 14 ' - 1 " A B B C 30'' CLR 30'' CLR 12 6 11 3 3 11 16 9 9 7 10 13 13 11 5 5 15 3'-5 1/2" 36'' CLR. FRONT OF PANEL 15 14 14 BEDROOM#1 10FT CL'G KITCHEN 10FT CL'G LIVING 10FT CL'G BEDROOM#2 10FT CL'G W.I.C 10FT CL'G BATH#1 10FT CL'G BATH#2 10FT CL'G PORCH CLOSET 4' - 6 1 / 2 " EE&RO EE&RO 18 18 19 19 2 AD.20 2 AD.20 88 21 NOTE: NO INSULATION NO HEATING NO COOLING 20 17 2 AD.20 6 AD.20 2'' 4 11 2020 10FT CL'G 19 COVER PORCH 12'-0" 6'-4"6'-0" 7 1 1 1 1 21 ' - 5 " EELECTRICAL VEHICLE CHARGING STATION LOCATION. 208/240-VOLT BRANCH CIRCUIT (40 AMP) 1 B A.06 B A.06 1'-0"1'-0" 6' - 2 " 1' - 0 " 1'-0" WA L L L I N E B E L O W WALL LINE BELOW WALL LINE BELOW WA L L L I N E B E L O W WA L L L I N E B E L O W WALL LINE BELOW WALL LINE BELOW WA L L L I N E B E L O W A.06 2 A. 0 6 3 A.06 1 A. 0 6 4 ROOF MATERIAL COVERING CLASS "A", TO MATCH WITH EXISTING ROOF (EXISTING ROOFING MATERIAL TYPE: ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537). OVER PLYWOOD SHEATING OVER RADIANT BARRIER OVER RAFTERS PWE STRUCTURAL DWGS. 3'-0" 4:12 4: 1 2 4: 1 2 A A.06 A A.06 O'HAGIN VENT 72 SQ.IN TYP. O'HAGIN VENT 72 SQ.IN TYP. 3FT MIN. 3' - 4 " 3FT MIN. 3'-0" O'HAGIN VENT 72 SQ.IN TYP. FUTURE SOLAR ZONE 100 SF FUTURE SOLAR ZONE 160 SF POST BELOW POST BELOW 2 AD.20 2 AD.20 2 AD.20 1' - 0 " 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1' - 0 " 11" RIDGE VENT 10'-0" EQEQEQ EQ EQ EQ IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK A.05 PROPOSED ADU FLOOR & ROOF PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 1/4" = 1'-0"1PROPOSED ADU FLOOR PLAN 1/4" = 1'-0"2PROPOSED ADU ROOF PLAN ROOF VENTILATION NOTES: (CRC R806)PLAN KEYNOTES FLOOR PLAN NOTES PLAN LEDGEND ROOF VENTILATION CALCULATION ROOF PLAN GENERAL NOTES 1. ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & PER THE INSTALLATION OF ROOF COVERING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 2. PROJECTIONS LESS THAN 5'-0" (HOUSE WITH NO SPRINKLER) TO PROPERTY LINE TO BE 1-HOUR CONSTRUCTION, TYP. 3. ROOF VENT : SEE ROOF VENTILATION CALCULATION. 901 E Myrtle St Unit# 2 - 1011181606/27/2024 1. PROVIDE FIRE BLOCKING IN CONCEALED SPACES 10' O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES, CRC R302.11. 2. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" TO THE EXPOSED GROUND SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY, CRC R317.2(2). 3. ALL WALLS TO BE SMOOTH FINISH U.N.O. 4. CONTRACTOR TO INCLUDE ALL FINISH AND COLOR SPECIFIED BY OWNER AND INTERIOR DESIGNER. 5. CONTRACTOR TO VERIFY W/ OWNER'S INTERIOR DESIGNER FOR MATERIAL SELECTION AND COLOR PRIOR TO FINAL PRICING AND CONSTRUCTION. 6. MIN. 3/8" CDX PLYWOOD THROUGH-OUT @ OUTSIDE FACE OF WALL 7. CONTRACTOR TO INCLUDE INSULATION OF CLOSET ORGANIZER. (SELECTED BY OWNER) 8. CONTRACTOR TO VERIFY ALL OWNER'S APPLIANCE MANUAL SPEC. PRIOR TO CONSTRUCTION. 9. DESIGN BUILT CABINET TO FIT 10. ALL INTERIOR, DOOR, WINDOW SIDE, HEAD AND SILL TO BE MOLDING 11. EXTERIOR CONCRETE LANDING TO COMPLY 2022 CRC R311.3 A. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A DIMENSION OF NOT LESS THAN 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT). B. LANDINGS AT THE REQUIRED DOOR SHALL NOT MORE THAN 1 1/2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. EXCEPTION: THE LANDING SHALL BE NOT MORE THAN 7 3/4 INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING 12. GROUND ADJACENT TO THE FOUNDATION SHALL FALL A MINIMUN OF 8 INCHES WITHIN THE FIRST 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE FOUNDATION WALL. (CRC R401.3) XX DOOR TYPE, SEE SCHEDULE A.10 WINDOW TYPE, SEE SCHEDULE A.10 XX KEY NOTE XX LEGEND EE&RO EGRESS ESCAPE AND RESCUE OPENING 3 4 7 8 5 6 ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & TEXTURE TO MATCH EXISTING HOUSE. STUCCO, PAINT AND MATERIAL TO MATCH EXISTING1 2 FASCIA & TRIMMING -PAINT TO MATCH EXISTING HOUSE 2 1/2" VINYL MOLDING TRIM FOR ALL WINDOWS TO MATCH EXISTING HOUSE CONCRETE LANDING ROOF VENTS WOOD POST TEMP. OBSCURED GLASS 9 TEMPERED GLASS A 6x8 RIDGE BOARD PER STRUCT. B 2x8 ROOF RAFTER PER STRUCT. C 2x8 CEILING JOISTS PER STRUCT D CONCRETE SLAB PER STRUCT. E FOOTING PER STRUCT. F 2x4 STUD WALL PER STRUCT. G ATTIC INSULATION PER T-24 H WALL INSULATION PER T-24 I WEEP SCREED FOR STUCCO, 2" ABOVE PAVED AREAS, 8" ABOVE NATURAL GRADE J K DEPTH OF EAVE TO MATCH MAIN DWELLING, TYP. O'HAGIN VENT 72 SQ.IN TYP. L 1HR FIRE RESISTANCE EAVE, SEE DTL 05/ AD.20 M 1-HR FIRE RATED WALL, SEE SHEET 01/AD20 FOR DETAIL. ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 15' -0" 6' - 8 " 1'-0"11" 1'-0" 1'-0" 4:12 4:12 4: 1 2 2' - 8 " 4' - 0 " 5'-0" 6' - 8 " 5'-0" 8" 10 ' - 0 " AD U M A X . H E I G H T 15 ' - 0 " 9 1 4 6 EE&RO EE&RO 4 A 5 2 3 6 F.S.D = 4 FT (3FT<F.S.D<5FT) UNPROTECTED OPENING MAXIMUM 25% WALL AERA. WALL AREA = 282 SF, OPENING = 20 SF. 20 / 282 = 7.1 % <25% (OK) WINDOW = 20 SF (N) GARAGE 8 4:12 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 15' -0" 6' - 8 " 4:12 4:12 2' - 0 " 4' - 8 " 1'-0"1'-0"2'-0"2'-0"1'-0" F.S.D 3'-0" F.S.D 3'-0" TO (E) STRUCT 6'-0" (E ) M A I N H O U S E F. S . L 10 ' - 0 " 8" (N ) A D U M A X . H E I G H T 15 ' - 0 " 3 2 1 B 3'-0" 6' - 8 " 1 8 55 6 9 7 4 4: 1 2 1 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 15' -0" 10 ' - 0 " 4: 1 2 4:12 4:12 1'-0" 1'-0" 6' - 8 " 4' - 8 " 2' - 0 " 8" 7' - 0 " 3' - 6 " 3' - 6 " (N) ADU GARAGE (N ) A D U M A X . H E I G H T 15 ' - 0 " C B 6 1 F.S.D = 4 FT (3FT<F.S.D<5FT) UNPROTECTED OPENING MAXIMUM 25% WALL AERA. WALL AREA = 547 SF, OPENING = 17.25 SF. 17.25 / 547 = 3.2% <25% (OK) 2'-6" 3'-6" WINDOW = 12,25 SF WINDOW = 5 SF 2 4'-0" TO PROPERTY LINE 5'-0" 7 4 4 PR O P E R T Y L I N E 3 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 15' -0" 2'-0"2'-0"1'-0" 1'-0" 4: 1 2 4: 1 2 (N) GARAGE 8" 10 ' - 0 " (N ) A D U M A X . H E I G H T 15 ' - 0 " 2 1 8 3 1'-0" TO (E) STRUCT 6'-0" 3'-10" TO PROPERTY LINE 4'-10" (E ) M A I N H O U S E F.S.D 3'-0" F.S.D 3'-0" F. S . L 5 PR O P E R T Y L I N E ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 15' -0" GARAGE 4:124:12 1'-0"1'-0"R38-INSULATION R19-INSULATION 10 ' - 0 " 8" AD U M A X . H E I G H T 15 ' - 0 " D EE 6 AD.20 ED CG B J J AD.20 3 1 AD.10 1 AD.20 A BATH#2 10FT CL'G BATH#1 10FT CL'G LIVING 10FT CL'G KITCHEN 10FT CL'G CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING R15-INSULATIONR15- INSULATION ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 15' -0" CEILING SOFFIT REF.CLOSET DE E F H G C F H I 1 AD.20 1'-0"1'-0" J B G CR38-INSULATION R19-INSULATION 2 AD.20 M A L BEDROOM#1 10FT CL'G KITCHEN 10FT CL'G CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING R15- INSULATION R15- INSULATION IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK A.06 PROPOSED ADU SECTIONS & ELEVATIONS (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 1/4" = 1'-0"1PROPOSED ADU NORTH ELEVATION 1/4" = 1'-0"4PROPOSED ADU WEST ELEVATION 1/4" = 1'-0"2PROPOSED ADU SOUTH ELEVATION 1/4" = 1'-0"3PROPOSED ADU EAST ELEVATION 1/4" = 1'-0"BPROPOSED SECTION B-B1/4" = 1'-0"APROPOSED SECTION A-A ELEVATION KEYNOTES ELEVATION & SECTION NOTES SECTION KEYNOTES 11 901 E Myrtle St Unit# 2 - 1011181606/27/2024 RE F . DW DOOR/WINDOW REMARKS: (1) DOOR SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WHEN MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP,WITH THE DOOR OPEN AT 90 DEGREE. (2) DOOR SHALL HAVE A MINIMUM CLEAR HEIGHT OF 78", MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP (3) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (4) SELF-CLOSING, TIGHT FITTING, SOLID WOOD, 1-3/8'' THICK DOOR, NOT LESS THAN 20- MIN FIRERATED DOOR AT OPENING TO DWELLING (CBC 715.4.3). (5) THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY CALCULATIONS. (6) THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. (7) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (8) ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, ASER-ETCHED, OR EMBOSSED PER CRC 2406.3. (9) DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE (10) GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR 1. ALL DOORS AND WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE. 2. ALL EXTERIOR DOORS & WINDOWS SHALL BE WEATHER TIED AND PROVIDE WITH INSECT SCREEN-METAL. DOORS & WINDOWS SHALL BE IN COMPLIANCE WITH ANSI. STD. A13 OR A1342. 3. THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY CALCULATIONS. 4. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. 5. ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, LASER-ETCHED, OR EMBOSSED PER CRC 2406.3. 6. GLAZING AND INSULATION SHALL CONFORM TO THE STATE ENERGY INSULATION STANDARD. 7. DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE) 8. GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR 9. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY SURFACE AVAILABLE FOR USE BY THE PUBLIC SHALL BE CAPABLE OF BEING LOCKING SECURELY. MOVEABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME. 10. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING DOOR. SUCH VIEW MAY BE POVIDED BY A DOOR VIEW, A VIEW PORT, WINDOW, OR OTHER OPENING. 11. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUM THROW OF 1 INCH AND AN EMBEDMENT OF NOT LESS THAN 5/8 INCH. 12. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORS SHALL BE EQUIPPED WITH A DEAD BOLT. 13. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM THE OUTSIDE WHEN THE DOOR IS CLOSED. 14. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/2" THICK. 15. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/4" THICK. 16. ANY GLASS WHICH IS LOCATED WITHIN 40 INCHES OF THE BLOCKING DEVICE ON A DOOR SHALL BE FULLY TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR GRILLS. 17. IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM DOOR/WINDOW ROUGH OPENING DIMENSIONS WITH THE MANUFACTURE/SUPPLIER PRIOR TO BEGIN CONSTRUCTION 18. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. (R309.4) 19. EMERGENCY EGRESS: A. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. B. MIN. SET CLEAR HEIGHT OF 24 INCHES. C. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE FLOOR. FINISH NOTES: (1) SEAL AND PAINTED W/ A COAT FLAT VINYL. (2) UNDERCOAT AND FINISH W/SEMI-GLOSS ENAMEL (3) KNOCKDOWN TEXTURE. (4) TAPED DRYWALL JOINTS. (5) SPRAYED SIMULATED ACOUSTIC PLASTER. (6) ORANGE PEEL FINISH. 1.GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. CRC R702.3.7.1 2.ALL DOORS & WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE 3.CONCRETE SLAB AND UNDER FLOOR INSPECTIONS SHALL BE MADE AFTER IN-SLAB OR UNDER-FLOOR REINFORCING STEEL AND BUILDING SERVICE EQUIPMENT, CONDUITS, PIPING OR OTHER ANCILLARY BUILDING TRADE PRODUCTS OR EQUIPMENT ARE INSTALLED, BUT BEFORE ANY CONCRETE IS PLACED OR FLOOR SHEATHING IS INSTALLED, INCLUDING THE SUBFLOOR R109.1.1.1 4.ROUGH INSPECTION OF PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS SHALL BE MADE PRIOR TO COVERING OR CONCEALMENT, BEFORE FIXTURES OR APPLIANCES ARE SET OR INSTALLED, AND PRIOR TO FRAMING INSPECTION R109.1.2 5.WATER PIPING MATERIAL WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC 604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC 604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX 1 OF THE CPC AND MANUFACTURERS RECOMMENDED INSTALLATION STANDARDS. CPVC WATER PIPING REQUIRESA CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC 604.4.1.1 OF THE CPC PRIOR TO PERMIT ISSUANCE. BUILDING DEPT. NOTES: 8' - 5 1 / 2 " 5'-0" 17 " 17 " 2' - 1 1 1 / 2 " 2' - 1 0 " 2' - 8 " 8' - 5 1 / 2 " A.081 2 30'' CLR ADU F.F. 0' -8" ADU TOP PL 10' -8" 1' - 0 " 2' - 6 " 1' - 6 " 3' - 0 " 10 ' - 0 " CEILING SOFFIT RANGE RE F R I G E R A T O R 2' - 0 " ADU F.F. 0' -8" ADU TOP PL 10' -8" WI N D O W WI N D O W CEILING SOFFIT DISH WASHER 3' - 0 " 1' - 6 " 2' - 6 " 1' - 0 " 10 ' - 0 " RE F R I G E R A T O R 2'-1"1'-11"3'-6"1'-6" 8'-11" 1' - 0 " ADU F.F. 0' -8" MIRROR 3' - 0 " 6" 3' - 0 " 17"17" 6' - 0 " 2'-8"2'-10"2'-11 1/2" 8'-5 1/2" WI N D O W WI N D O W SHOWER ADU F.F. 0' -8" 5'-0" 3' - 0 " 3' - 0 " 3'-3"1'-9" 31 1/2" 6' - 0 " SHOWER 2'-0"2'-0"3'-6"1'-6" 9'-0" 3' - 0 " 2' - 0 " 2' - 6 " 2' - 0 " 1' - 6 " 2' - 0 " 13 ' - 0 " A.06 1 2 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM A.08 ROOM FINISH & DOOR/WINDOW SCHEDULE & INTERIOR DETAILS (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 NUMBE R DOOR SIZE QTY DESCRIPTION U-FACTOR SHGC REMARKS 1 3' - 0" x 6' - 8" 1 EXTERIOR DOOR 1 PANEL/TEMPERED GLASS, VINYL FRAME, PAINTED FINISH 0.5 ENTRY DOOR (1) (2) (3) (9) 2 2' - 8" x 6' - 8" 1 SOLID CORE 1 PANEL, WOOD FRAME, PAINTED FINISH, 20 MINUTES MIN. FIRE RATED DOOR GARAGE TO HOUSE (4) 3 2' - 8" x 6' - 8" 4 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR 4 5' - 0" x 6' - 8" 1 SIDELITE SOLID CORE/TEMP. GLASS, VINYL FRAME, PAINTED FINISH EXTERIOR (1) (2) (3) (9) 5 3' - 0" x 6' - 8" 1 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR 6 5' - 0" x 6' - 8" 1 SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH INTERIOR 7 8' - 0" x 8' - 0" 1 METAL GARAGE DOOR Grand total: 10 DOOR SCHEDULEXWINDOW SCHEDULEX ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARKS A 1 5' - 0" x 4' - 0"SLIDER, DUAL GLASS/ VINYL FRAME SOLID CORE, FINISH PER MFGR. 0.3 0.23 B 2 2' - 6" x 2' - 0"SLIDER, DUAL GLASS/ VINYL FRAME SOLID CORE, FINISH PER MFGR. 0.3 0.23 TEMP. OBSCURED @BATH (5), (10) C 1 3' - 6" x 3' - 6"SLIDER, DUAL GLASS/ VINYL FRAME SOLID CORE, FINISH PER MFGR. 0.3 0.23 Grand total: 4 DOOR/WINDOW NOTES ROOM FINISH SCHEDULE ROOM FLOOR BASE WALL MATERIAL WALL FIN. CEILING MATERIAL CEILING FIN. HEIGHT BEDROOM#1 VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' KITCHEN VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' LIVING VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' BEDROOM#2 VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' W.I.C VINYL WOOD 1/2'' GYP.BD. 1,3 1/2'' GYP.BD. 1,3 10'-0'' BATH#1 TILE WOOD 1/2'' GYP.BD. 2,3 1/2'' GYP.BD. 2,3 10'-0'' BATH#2 TILE WOOD 1/2'' GYP.BD. 2,3 1/2'' GYP.BD. 2,3 10'-0'' 1/2" = 1'-0"1PROPOSED ADU BATH#2 PLAN 1/2" = 1'-0"2KITCHEN ELEVATION 1 1/2" = 1'-0"3KITCHEN ELEVATION 2 1/2" = 1'-0"4PROPOSED BATH#2 SECTION1 1/2" = 1'-0"5PROPOSED BATH#2 SECTION 2 1/2" = 1'-0"6PROPOSED ADU KITCHEN PLAN 1. STRING SHALL BE FABRICATED FROM EITHER HARD-DRAWN SPRING WIRE ( PER ASTM A227-21) OR OIL-TEMPERED WIRE ( PER ASTM A229-71) 2. MINIMUM DESIGN STANDARD SHALL BE 9000 CYCLES. 3. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED TESTING AGENCY. 4. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED DEVICE CAPABLE OF RESTRAINING THE SPRING OR ANY PART THERE OF IN THE EVENT IT BREAKS. CONTAINMENT DEVICE SHALL BE TESTED AND CERTIFIED BY AN APPROVED TESTING AGENCY. GARAGE DOOR STRINGS PER SEC. R309.5 901 E Myrtle St Unit# 2 - 1011181606/27/2024 WHEN WALL IS SHEATHED ON THE EXTERIOR, LAP BOTH LAYERS OF BUILDING PAPER OVER THE WEEP SCREED FLANGE EXTERIOR FINISH GRADE MIN. 26 GA. G.S. PLASTER WEEP SCREED W/ 3-1/2" VERTICAL NAILING FLANGE STUCCO OVER 2 LAYERS GRADE 'D' PAPER PRESSURE TREATED WOOD PLATE SEAL TO CONCRETE W/ CONT. BEAD OF SEALANT WHEN WALL IS SHEATHED ON THE EXTERIOR, LAP BOTH LAYERS OF BUILDING PAPER OVER THE WEEP SCREED FLANGE CONC. SLAB FOOTING OR CURB CONCRETE SLAB MIN. 26 GA. G.S. PLASTER WEEP SCREED W/ 3-1/2" VERTICAL NAILING FLANGE STUCCO OVER 2 LAYERS GRADE 'D' PAPER PRESSURE TREATED WOOD PLATE SEAL TO CONCRETE W/ CONT. BEAD OF SEALANT CONC. SLAB FOOTING OR CURB MI N . 1 ' ' 6' ' M I N . TO F I N . G R A D E 8' ' M I N . MIN. 1' ' 6' ' M I N . TO FIN. GRADE 8' ' M I N . FIN. SLAB PER PLAN POLYVINYL-CHLORIDE COATED STEEL SPIRAL DUCT SIZE PER MECHANICAL ENGINEER W/ ALL JOISTS TAPED AND SEALED ANY AND ALL DUCK PENETRATIONS TO BE ABOVE 9.00 NAVD88 0' - 4 " 0' - 4" VAPOR BARRIER 4" MIN. CONCRETE SURROUND ALL DUCTS GRAVEL FILL FLOOR FINISH, SEE SCHEDULE SEE STRUCT. DWGS FOR SLAB UNDER LAYER FACE OF STUD PORCH SLAB ISOLATED SLAB FROM CONC. SEE STRUCT. SLAB AND UNDER LAYER SEE STRUCT. DWGS INTERIOR FINISH, SEE SCHEDULE INTERIOR FINISH, SEE SCHEDULE 2x4 STUD WALL FLOOR FINISH, SEE SCHEDULE 1/2" GYPSUM BOARD @ CEILING, U.N.O FLOOR PLYWOOD SHEATHING, PER. STRUCT. FLOOR JOISTS, PER .STRUCT. CLEVAGE MEMBRANE METAL LATH MORTAR BED WATERPROOF MEMBRANE OR CRACK ISOLATION MEMBRANE, OPTIONAL FOR WET AREABOND COAT CERAMIC TILE IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM AD.10 ARCHITECTURAL DETAILS (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 N/A 1WEEP SCREET N/A 2UNDER SLAB DUCT SYSTEM N/A 6HOUSE TO PORCH N/A 3NON-BEARING WALL N/A 9WINDOW SILL -STUCCO-TRIM N/A 10DOOR JAM AT EXT. WALL N/A 12WINDOW SILL N/A 13DOOR HEAD/JAM N/A 14VENT THROUGH ROOFN/A 17CERAMIC TILE FLOORING N/A 7WINDOW HEAD-STUCCO N/A 15WINDOW SILL-SHOWER N/A 16WINDOW JAM-STUCCO 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SEE PLAN ROOFING (SEE PLAN) OVER 2 LAYERS 30# BUILDING PAPER OVER ROOF SHEATHING OVER RADIANT BARRIER OVER ROOF FRAMING 2X BLK'G GUTTER WHERE OCCURS 1x4 OVER 2x6 FASCIA 1X4 ''V'' GROOVE T+G SOFFIT OVER 5/8'' TYPE 'X' GYP. BD WHEN LESS THAN 5'-0" TO PROPERTY LINE SEALANT EXT . MATERIAL OVER HOUSEWRAP COPPER FLASHING 1/2" GYP. SEE FINISH SCHEDULE 1/2" GYP. WHERE SLOPE CEILING OCCURS. STUCCO SYSTERM ON LATH, INSTALL PER MFR, MATCH TO EXISTING HOUSE. ROOFING (SEE PLAN) OVER 2 LAYERS 30# BUILDING PAPER OVER ROOF SHEATHING OVER RADIANT BARRIER OVER ROOF FRAMING ROOFING 2x FLAT OUTRIGGER @24" O.C. ROOF FRAMINGDRIP EDGE FLASHING ROOF FASCIA 1/2" GYP. SEE SCHEDULE 1X4 ''V'' GROOVE T+G SOFFIT OVER 5/8'' TYPE 'X' GYP. BD WHEN LESS THAN 5'-0" TO PROPERTY LINE SEALANT EXT . MATERIAL OVER HOUSEWRAP STUCCO SYSTERM ON LATH, INSTALL PER MFR, MATCH TO EXISTING HOUSE. 2" X 4" WOOD STUDS AT 16" WITH DOUBLE TOP PLATES, SINGLE BOTTOM PLATE; INTERIOR AND EXTERIOR SIDES COVERED WITH TYPE X GYPSUM WALLBOARD AND SHEATHING, RESPECTIVELY, 4' WIDE, APPLIED HORIZONTALLY OR VERTICALLY WITH VERTICAL JOINTS OVER STUDS, AND FASTENED WITH 2 1/4" TYPE S DRYWALL SCREWS, SPACED 12" ON CENTER. CAVITY TO BE FILLED WITH 3 1/2" " MINERAL WOOL INSULATION. PER CBC TABLE 721.1(2) ITEM 15-1.15 7/8" 3-COATS STUCCO OVER METAL LATH/WALL SIDING WHERE OCCUR. 2 LAYERS OF GRADE "D" BUILDING PAPER (VAPOR BARRIER) PLYWOOD SHEATHING (PER STRUCTURAL DESIGN) MIN. MIN. 3/8" CDX PLYWOOD 2X4 FRAMING INSULATION PER T-24 1 LAYER OF 5/8" TYPE "X" GYPSUM BOARD CAUKLING ROOF RAFTER 2x FULL HEIGH FIRE BLOCK NO VENT HOLE ALLOWED SOLID FASCIA SLOPE 5% MIN. AT N.G SLOPE 2% MIN. AT PAVED CBC TABLE 721.1(2) ITEM 15-1.15 1/2" GYP. VAULTED CEILING WHERE OCCUR 5/8" TYPE "X" GYP. SHEATHING FOR OVERHANGE DETAIL 05 SEE AD.20 ROOFING (SEE PLAN) OVER 2 LAYERS 30# BUILDING PAPER OVER ROOF SHEATHING OVER RADIANT BARRIER OVER ROOF FRAMING 1/2" GUPSUM WALLBOARD OR SHEATHING APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6D COOLER OR WALLBOARD NAILS AT 7" O.C. WITH END JOINTS ON NAILING MEMBERS. STAGGER JONTS EACH SIDE. U OCC. GARAGEEXTERIOR MINIMUM 2X4 WOOD STUDS AT 16" O.C MAXIMUM 5/8" GUPSUM SHEATHING (EXTERIOR EXPOSURE) NAILED WITH I 3/4" BY NO.II GAUGE BY 7/16" HEAD GALVANIZED NAILS AT 8" O.C. FINISH MATERIALS NAILE WITH MINIMUM 7D GALVANIZED SMOOTH BOX NAILS (VERIFY WITH MATERIAL MAUFACTURER) OVER BUILDING PAPER ALL NON-FIRE RATED FINISH MATERIALS WALLS THAT SUPPORT THE STRUCTURE OF OCCUPANCY ABOVE REQ'D FIRE BARRIER CRC SEC. R302.6 MINIMUM 2X4 WOOD STUDS AT 16" O.C MAIMUM 7/8" EXTERIOR CEMRNT PLASTER (MEASURES FROM THE FACE OF STUDS) ON THE EXTERIOR SURFACE PLASTER MIX 1:4 FOR SCRATCH COAT AND 1:5 FOR BROWN COAT, BY VOLUME, CEMENT TO SAND. OVER METAL LATH OVER BUILDING PAPER 1/2" GUPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6D COOLER OR WALLBOARD NAILS AT 7" O.C WITH END JONTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. U OCC. GARAGEEXTERIOR 2X FRAMING BATT INSULATION 1 LAYER OF 5/8" TYPE "X" GYPSUM BOARD EXTEND FROM FOUNDATION TO THE ROOF SHEATING 1/2" GYP. CEILING 1/2" GYP. CEILING TYP. 1/2" GYPSUM BOARD ROOF PLYWOOD SHEATHING PER STRUCT. CONCRETE FOUNDATION/SLAB PER STRUCT. GARAGE U-OCC. HOUSE R3-OCC. 1 2% SLOPE FLOOR FINISH, SEE SCHEDULE SEE STRUCT. DWGS FOR SLAB UNDER LAYER PRESSURE TREATED WOOD PLATE SEAL TO CONCRETE W/ CONT. BEAD OF SEALANT 1 LAYER OF TYPE "X" GYP. FROM FOUNDATION TO THE UNDER SIDE OF FLOOR/ROOF SHEATHING, SEE FINISH SCHEDULE 1/2" GYP. SEE FINISH SCHEDULE 2x STUD WALL, SEE STRUCT. INSULATION PER T-24 GARAGE SLAB 1/2 " MIN. GYPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALT NAILED WITH 6D COOLER OR WALLBOARD NAILS AT 7" O.C WITH END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE.MINIMUM 2X4 WOOD STUDS AT 24" O.C MAIMUM MINERAL / GLASS FIBER BATT INSULATION NON-RATED FINISH MATERIAL NON-RATED PENNETRATION ALLOWED ON THIS SIDE U OCC. GARAGE R-3 OCC DWELLING REQ'D FIRE BARRIER CRC SEC. R302.6 1/2" GUPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6D COOLER OR WALLBOARD NAILS AT 7" O.C WITH END JONTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. U OCC. GARAGE U OCC. GARAGE SUPPORT POST LESS THAN 8X8 (NOMINAL)22-GA STEEL JACKET AROUND COLUMN OR CORNER GUARDS FOR IMPACT PROTECTION NOT LESS THAN 5FT ABOVE F.F < 8X8(NORMINAL) REQ'D FIRE BARRIER CRC SEC. R302.6 POSTS THAT SUPPORT THE STRUCTURE OF OCCUPANCY ABOVE IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK AD.20 ARCHITECTURAL DETAILS (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 N/A 5EAVE DETAIL N/A 1ROOF GABLE OVERHANG N/A 21HR EXT. WALL AND ROOF OVERHANG N/A 4SUPPORT WALL N/A 61HR FIRE WALL HOUSE/GARAGE N/A 3HOUSE TO GARAGE. N/A 7GARAGE TO DWELLING N/A 8ISOLATED POST 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/26/2023 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/26/2023 S-0.20 TY P I C A L D E T A I L S EXTERIOR SHEATHING SEE ARCH. FOR INSULATION AND MEMBRANE STEEL ANGLE SCHEDULE SIZE SPAN MAX. L4x3 1/2x3/8 L6x3 1/2x1/2 L7x4x5/8 8'-0" 14'-0" 16'-0" ADD 9 GAUGE WIRE JOINT REINF. @24" O.C. VERTICAL FOR BUILDING IN SEISMIC DESIGN CATEGORIES C, D, E, F. FERO PAC-TIE WITH 2-#6 x 2" DECK SCREW AND WASHERS AS FOLLOWS: - TYPICAL AT 16" HORIZONTAL AND AT 24" VERTICAL - AROUND OPENINGS AT 12" HORIZONTAL AND AT 16" VERTICAL - NOT MORE THAN 12" FROM EDGE OF OPENINGS. - LOCATE ROW OF TIES MAX 12" ABOVE BEARING LEVEL AND 8" FROM TOP OF WALL. LLV STEEL ANGLE SUPPORT 3'-6" VENEER HEIGHT MAX AND NEED TO EXTENT AND BEAR ON EACH SIDE OF OPENING 4" MIN. SEE SCHEDULE FOR SIZE STUD WALL PER PLAN BEAM OR HEADER PER PLAN 1/2" DIA. LAG SCREW @12" O.C. WITH 2.5" MIN. EMBED TO BEAM OR HEADER OPENING VENEER TO WOOD WALL 4 2 3 5 6 TY P I C A L D E T A I L S 1 810 11 7 8 9 12 CONCRETE FLOOR CONDITION WOOD FLOOR CONDITION 1' MIN.PARTIAL SHEET AT WALL END ONLY 1' MI N . WH E R E RE Q ' D 7" MI N . STAGGER HORIZ. PANEL JOINTS, TYP OR USE FULL HEIGHT SHEETS WHERE POSSIBLE FULL SIZE PLYWOOD SHEET TYP. U.O.N. END POST AT HD EDGE NAIL TO HOLD DOWN END POST ANCHOR BOLTS PER SHEAR WALL SCHEDULE EDGE NAIL TO SILL BLK'G AT PANEL EDGES SAME SIZE AS PANEL EDGE STUD WITH STAGG. E.N. FIELD NAILING @12" O.C. EDGE NAIL AT PANEL EDGES TYP. STUDS PLYWOOD FACE GRAIN PARALLEL TO STUD EDGE NAIL TO SOLE PLATE SOLE PLATE NAILING A35 PER SHEAR WALL SCHEDULENOTES: 1.PROVIDE STAGGERED NAILING AT ALL PANEL EDGES. 2. STUDS ARE SPACED @ 16" O.C. MAX. U.O.N. 3. PROVIDE 1/8" GAP BETWEEN ADJACENT PANELS. EDGE NAIL TO TOP PLATES STAGGER NAILS EDGE NAIL AT ALL VERTICAL PANEL SPLICES (STAGG.). POST SIZE AT SPLICE PER SHEAR WALL SCHEDULE NOTES. SHEAR WALL FRAMING ELEVATION 1/ 2 " GA P FLOOR LINE H TOP OF PARTITION PARALLEL TO JOISTS 1/ 2 " GA P FLOOR LINE H TOP OF PARTITION PERPENDICULAR TO JOISTS 1/2 "GAP TOP OF PARTITION TO CONC. SLAB 1/ 2 " GA P 4x W/ 1/2" Ø HILTI KH-EZ @48" O.C. W/ 5" EMBED EA SIDE DBL. TOP PLATES CEILING WHERE OCCURS SLAB PER PLAN 2-16d TOE NAIL 2x4 FLAT @ 48" O.C. DBL. TOP PLATES 2x6 BRACING W/ (3)16d EA END @ 8'-0" WHERE WALL IS: 2x4 AND H> 14'-0" 2X6 AND H> 22'-0" PROVIDE 2x6 CONT. @ MIDSPAN WHERE BRACE EXCEEDS 6'-0" W/(2) 16dCEILING WHERE OCCURS SIMPSON DTC (SLOT VERTICAL) AT EA JOIST OR RAFTER DBL. TOP PLATES CEILING WHERE OCCURS SIMPSON DTC (SLOT VERTICAL) CLIP @ EA RAFTER CEILING WHERE OCCURS SIMPSON STCT CLIP (SLOTS VERTICAL) WHERE REQUIRED @ EA RAFTER PARTITION WALL (NON-BEARING/ NON-SHEARWALL) FRAMING AT NON BEARING WALLS NON BEARING WALLS FLOOR JOIST PER PLAN SIMPSON Z CLIP EA. END 2X BLOCKING @16" O.C. SIMPSON Z CLIP EA. END 2X BLOCKING @16" O.C. WALL PARALLEL TO JOIST WALL PERPENDICULAR TO JOIST NON BEARING WALLS PROVIDE DOUBLE JOISTS UNDER NON BEARING WALLS NON BEARING WALLS PROVIDE FULL HEIGHT BLK'G UNDER NON BEARING WALLS 2x SAWN LUMBER 1 3/4" ENGINEERED LUMBER WEB STIFFENER WALL PARALLEL TO JOIST OPTION NOTES: 1. NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING. 2. PLYWOOD OSB PIECES SHALL CONTAIN NOT LESS THAN 8 SQ. FT. NOR BE LESS THAN 2-0" WIDE. 3. MAXIMUM UNSUPPORTED SHEATHING TO BE 24". 4. FRAMING AT ADJOINING PANEL EDGE SHALL BE 3" NOMINAL OR WIDER AND NAILS AT ALL PANEL EDGES SHALL BE STAGG. WHERE PANEL EDGE NAILING IS SPECIFIED AT 2 1/2" 0.C. OR LESS. 5. ALL PANEL EDGES OF THE FLOOR SHEATHING SHALL HAVE APPROVED T AND G JOINTS OR SHALL BE SUPPORTED BY BLK'G. PER IBC/CBC TABLE 2304.8 (3) FOOTNOTE D. 6. DIAPHRAGM BOUNDARY SHALL BE SUPPORTED BY FRAMING MEMBERS WITH BOUNDARY NAILING. SECTION A-A PLAN 1/8" GAP 4'-0"x8-0" SHEETS, STAGG. AS SHOWN FIELD NAINILG SHEATHING EDGE NAILS 2x MIN. FRAMING DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT DISCONTINUOUS EDGE W/2x MIN. FRAMING BLK'G. CONT. EDGE W/2x MIN. BLK'G. AT BLOCKED DIAPHRAGM JOIST PER PLAN CONT. EDGE W/O BLK'G. @ UNBLK'G. DIAPHRAGMEDGE NAILING STAGG. AA PANEL JOINT ROOF OR FLOOR SHEATHING LAYOUT 4' - 0 " M A X 1" MIN PENETRATION SECTION OF DOUBLE JOISTS PLAN VIEW NOTES: SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF OPENING WOOD JOISTS PER PLAN SHEATHING PER PLAN MSTA30 W/2x BLOCK TYP. @ CORNER DOUBLE JOISTS TAIL JOIST HANGER PER PLAN EDGE NAILING COMMON NAILS @ 6" O.C. EACH FACE TOP AND BOTTOM WEB STIFFENER AT HANGER (I-JOIST ONLY) TYP. FLOOR AND ROOF OPENING 1. 1/2" 3D MAX. L/3 MIN. D MIN. D/ 4 MA X . 2" M I N 2" M I N D/ 5 MA X . D ℄ JOIST AND HOLE NOTE: 1. D = DEPTH OF JOIST OR BEAM D1= STUD WIDTH L = CLEAR SPAN 2. PERDRILL CORNERS OF NOTCHES 3. NOTCH MAY OCCUR TOP OR BOTTOM, NOT BOTH. 4. NOTCHES AND HOLES ARE NOT ALLOWED IN CANTILEVER PORTION OF JOISTS. 5. MAX. ALLOWED IS A COMBINATION OF TWO NOTCHES AND/OR HOLES IN L/3 SPAN. D/ 6 MA X . RAFTER, JOIST OR BEAM DRILLING HOLES AND NOTCHING OF THE JOIST ROOF TRUSSES OR RAFTER PER PLAN NOTE: - USE PRE-FAB. STEP-DOWN TRUSSES PERPENDICULAR TO ROOF TRUSSES IN-LIEU OF 2x JACK RAFTERS 2x4 OR 2X6 RAFTERS @ 24" O.C. MAX. MAX. SPAN: 2x4 = 4'-0" 2x6 = 8'-0" 2x VALLEY PLATE W/(3) 16d INTO EACH RAFTER OR TRUSS ADD 2x4 STRUT FROM JACK RAFTER TO RAFTER OR TRUSS BELOW TO LIMIT OVER FRAMING RAFTER SPAN 2x RIDGE BOARD W/ DEPTH GREATER THAN JACK RAFTER OVER FRAMING INTERSECTION w/ POST INTERSECTION w/o POST OUTSIDE CORNER w/ POST OUTSIDE CORNER w/o POST NOTE: SEE FRAMING PLAN FOR SHEAR WALL LOCATIONS, ORIENTATIONS AND SCHEDULE REFERENCES 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD PLYWOOD AT DOUBLE-SIDED WALL POST AT PER PLAN 16d @ 12" O.C. POST AT PER PLAN 2x OR 3x STUD AS REQ'D., TYP. PER S.W. SCHED. PLY. CONT. THRU WALL INTERSECTION ATDOUBLE-SIDED WALL 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD DOUBLE 2x, MIN. 16d @ 12" O.C. SHEAR WALL/ INTERSECTION DOUBLE STUDS 16d @24" O.C. TYP. WALL INTERSECTION DOUBLE TOP PLATES SILL PLATE NOTE : WHERE NOTCH IS GREATER THAN 1" PROVIDE 10 GA STRAP W/ WIDTH SAME AS DBL TOP PL.TOP PL OF SHEAR WALLS SHALL NOT BE NOTCHED UNLESS SPECIFICALLY DETAILED. NOTE : WHERE DEPTH OF NOTCH "B" OS GREATER THAN D/5 PROVIDE ANCHOR BOLT EA SIDE OF NOTCH PER END REQUIREMENT. NO MORE THAN ONE NOTCH IS PERMITTED IN EVERY 12'-0" @ SHEAR WALL 5" MIN. 9" MAX. 5" MIN. 9" MAX. 5" MIN. 9" MAX. 2D MIN. D D/ 2 D/ 2 "B" 8" MAX @ SHEAR WALL "B " D/ 3 8) 16D SIDE OF NOTCH (4PL) 5" 3" MAX.5"NOTCH D/ 2 MA X . 2D MIN. D/ 3 D/ 2 D/ 2 D DRILLED HOLE END OF SILL PL END OF SILL PL PLATE NOTCH AT NON SHEAR WALL NON BEARING STUDS BEARING STUDS NOTES: 1. NOTCHING AND BORING SHOULD NOT OCCUR IN SAME STUD SECTION 2. NO MORE THAN TWO SUCCESSIVE DOUBLE STUDS MAY HAVE 60% MAX BORING HOLES 5/8" MIN. DISTANCE TYP. ALL STUD 5/8" MIN. DISTANCE TYP. ALL STUD 1-1/2" 1-1/2" 40% MAX. STUD WIDTH NOTCH 60% MAX. STUD WITH BORE NOTCH SCHEDULE 25% 40% 60% 7/8" 1-3/8" 2" 2 x 4 % OF STUDS NOTCH/BORE 1-3/4" 2-1/8" 4-1/4" 2 x 8 60% MAX. STUD WITH BORE STUD NOTCHING/BORING LIMITS 1-3/8" 2-1/8" 3-1/4" 2 x 6 POST SEE PLAN OR SOLID BLK'G. SEAT ON HEADER (2)2x TOP PL'S PROVIDE FULL WIDTH BLK'G. UNDER POST ABOVE JOIST SEE PLAN FOR DIRECTION POST SEE PLAN SIMP. A34 EACH SIDE 2x SOLE PL. PLYWOOD SHEATHING SEE PLAN BLOCKING AT POSTS/TRIMMERS13 NOTES: 1. INSTALL SOLE PLATE ANCHORAGE AS SHOWN AND AT SPACING INDICATED IN WOOD SHEARWALL BASE CONNECTION SCHEDULE. 2. STAGGER ANCHORS AT DOUBLE SIDE OF SHEARWALL SHEARWALL WHERE OCCURS SOLE PLATE ANCHORAGE PER SHEARWALL SCHEDULE 1/2" MAX. SHEARWALL WHERE OCCURS CONCRETE SLAB PLATE WASHER 0.229"x3"x3"- MIN. @SHEARWALL APPLICABLE NOTE 2@SHEARWALL APPLICABLE NOTE 2 WOOD SHEARWALL SILL PLATE ANCHORAGE 1/2" MAX. 14 SPLICE LENGTH OF REINFORCEMENT REBAR TENSION SPLICE LENGTH (PROVIDED MASONRY COVER, CLEAR BAR SPACING AND TRANSVERSE REINFORCEMENT ARE IN COMPLIANCE WITH ACI 530-13, SECTION 9.3.3.3 ) fy f'm 1500 3 4 5 6 7 8 9 SPLICE LENGTH IN INCHES 19 34 45 54 63 72 81 18 30 45 54 63 72 81 18 26 41 54 63 72 81 18 24 38 54 63 72 81 BAR SIZE (psl)(psl) 2000 2500 3000 60000 CLASS B REBAR TENSION SPLICE LENGTH (PROVIDED CONCRETE COVER, CLEAR BAR SPACING AND TRANSVERSE REINFORCEMENT ARE IN COMPLIANCE WITH ACI 318-19, CHAPTER 25) f'c 25 0 0 P S I NO R M A L WE I G H T CO N C R E T E 30 0 0 P S I NO R M A L WE I G H T CO N C R E T E LOCATION *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS Fy 40 60 40 60 40 60 40 60 3 4 5 6 7 8 9 10 11 SPLICE LENGTH IN INCHES 20 27 34 41 59 68 76 86 95 30 41 51 61 89 101 114 129 143 16 21 26 31 46 52 59 66 73 23 31 39 47 68 78 88 99 110 19 25 31 37 54 62 70 78 87 28 37 46 56 81 93 104 118 131 14 19 24 28 42 47 54 60 67 21 28 36 43 62 71 80 90 100 45 0 0 P S I NO R M A L WE I G H T CO N C R E T E *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS 40 60 40 60 17 22 28 33 49 55 63 70 78 25 33 42 50 73 83 94 105 117 13 17 22 26 37 43 48 54 60 19 26 32 38 56 64 72 81 90 15 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 FRAMING NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.USP CONNECTORS CAN BE USED IN LIEU OF SIMPSON STRONG TIE IN THIS PROJECT. CONTACT E.O.R. FOR CONVERSION TABLE OR SUBMIT SHOP DRAWINGS TO E.O.R. FOR REVIEW AND APPROVAL. 4.ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS, UNO. ON PLAN OR DETAIL. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ALL FRAMING LEVELS (3B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 x 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.HEADER AT NON-BEARING WALLS, USE 2x4 FOR OPENINGS UP TO 3'-0" MAX., (2)2x4 FOR OPENINGS UP TO 6'-0" MAX., 4x6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). USE 4x4 FOR OPENINGS LESS THAN 16" AT BEARING WALLS WITHOUT POINT LOADS. 9.WOOD HEADER OR POSTS MADE UP OF 2 OR MORE 2X'S SHALL BE SPIKED TOGETHER PER THE NAILING SCHEDULE. 10.SHEARWALL PANEL TO BE NAILED TO ALL MULTIPLE STUDS RECEIVING HOLDOWNS AND DO NOT BREAK AT PERPENDICULAR WALL LOCATIONS, UNO. FRAMING SCHEDULE DENOTES POST OR TRIMMER AS NOTED LEGEND KEY NOTES DENOTES SHEAR PANEL LENGTH DENOTES PANEL TYPE, REFER TO SHEARWALL SCHEDULE DENOTES BEAM NUMBER, REFER TO E.O.R. CALCULATIONS DENOTES FLOOR TO FLOOR HOLDOWN PER SCHEDULE IN DETAIL 1/SD3.0 DENOTES DIRECTION OF FRAMING MEMBER PER FRAMING SCHEDULE DENOTES DETAIL SHEET NUMBER DENOTES KEY NOTE NUMBER DENOTES BEARING WALL DENOTES OVER FRAMING DENOTES POST OR TRIMMER FROM FLOOR ABOVE DENOTES DETAIL NUMBER DENOTES DROP BEAM OR HEADER PER PLAN DENOTES FLUSH BEAM PER PLAN MARK MEMBER TYPE RR1 2 X 8 ROOF RAFTERS @ 16" O.C. X X X X SDX DENOTES DRAG DIRECTION BLOCKED ROOF DIAPHRAGM 8d's @ 4" B.N. 8d's @ 6" E.N. 8d's @ 12" F.N. 10 X X'-X" X X X CJ1 2 X 6 CEILING JOISTS @ 16" O.C. DENOTES FRAMING ZONE DIVISION X DENOTES SHEARWALL LINE IN CALCULATIONS GARAGE BEDROOM#1 10FT CL'G KITCHEN 10FT CL'G LIVING 10FT CL'G BEDROOM#2 10FT CL'G W.I.C 10FT CL'G BATH#1 10FT CL'G BATH#2 10FT CL'G 4x6 HDR 1 CONT. 4x8 HDR 4x6 HDR4x6 HDR 4x 6 H D R 4x6 HDR 4x 6 H D R 4x 6 H D R 4x6 HDR4x6 HDR 3 6x6 DR BM 2 6x 6 D R B M CA N T . C O L . 6x 6 2 6x 6 D R B M 4 3 1 / 2 " x 1 1 7 / 8 " L V L C L ' G B M R. R . W / E . N . R. R . W / E . N . 2x10 RIDGE BOARD RR 1 RR 1 2x 1 0 R I D G E B O A R D RR1RR1 R.R. W/E.N.R.R. W/E.N. R.R. W/E.N.R.R. W/E.N. 2x 1 0 R I D G E B O A R D RR1 RR1 4x4 A B C D SW2 8'-0"4x 4 4x 4 SW2 8'-0"4x 4 SW1 2'-3"4x 4 4x 4 SW1 2'-5"4x 4 4x 4 R.R. W/E.N.R.R. W/E.N. xWSWH AB1HS 12 10 1 SW 1 8' - 0 " 4x4 4x4 2 SW 2 8' - 0 " 4x4 4x4 3 SW 1 8' - 0 " 4x4 4x4 4 SW 1 8' - 0 " 4x4 4x4 CJ1CJ1 R.R. W/E.N.R.R. W/E.N. 1B SD2.0 1B SD2.0 1B SD2.0 2B SD2.0 2B SD2.0 2B SD2.0 4 SD2.0 4 SD2.0 4 SD2.0 4 SD2.0 4 SD2.0 5 SD2.0 5 SD2.0 5 SD2.0 5 SD2.0 6 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 CJ1 CJ 1 9 SD2.0 9 SD2.0 10 SD2.0 MIN 6'-0" RR W/EN 11A SD2.0 11A SD2.0 12 SD2.0 12 SD2.0 7 SD2.0 13 SD2.0 8 S-0.20TYP. 6 WSWH2 5 SD2.0 8 SD2.0 LOW HIGH 15 SD2.0 14 SD2.0 16 SD2.0 16 SD2.0 17 SD2.0 4x4 K.P. E 1 CA N T . C O L . 1 2022 CALIFORNIA BUILDING CODE (1), (3) (4) (2) (1) 870 (PLF) SHEAR ALLOWABLE 220 PANEL TYPE SHEAR 8 d's 10 d's @ 2" O.C. 8 d's @ 2" O.C. @ 3" O.C. 15/32" APA Structural I rated 3/8" APA rated 10 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's@ 6" O.C. 3/8" APA rated rated3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C.8 d's FIELD (COMMON) NAILING PERIODIC SPECIAL INSPECTION IS REQUIRED. (4) (2) (5) (6) USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). SINKER 16d's CONNECTION SILL PLATE @ 4" O.C. @ 6" O.C. @ 3" O.C. @ 2" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. @ 6" O.C. @ 5" O.C. SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. FRAMING CLIPS A35's, LS50's OR LTP4's (5), (6) 2 ROWS STAGG. @ 3" O.C. 1/4"Øx6" SCREWS SDS (8) 260 320 380 410 490 (7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. (8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. (9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. (9) (7) (7) (7) 3/8" APA rated 530 640 (7) (10)FOR DOUBLE SIDED SHEAR PANELS: (10)(10)(10) (10)(10)(10) (10)(10)(10) a. USE HALF THE SPACING OF SILL PLATE ANCHOR BOLTS FOR TYPES SW3, SW4 & SW5. c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND HALF THE SPACING, FOR TYPES SW3, SW4 & SW5. 5/8" Ø 2X A.B. SPC'G @ 24" O.C. @ 16" O.C. @ 8" O.C. @ 8" O.C. @ 6" O.C. 48" 42" 36" 24" 18" SHEAR WALL SCHEDULE (4) (2) (4) (2) (4) (2) (3)STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES SW4 & SW5. SW1 SW2 SW3 SW4 SW5 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 02/29/2024 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 02/29/2024 02 / 2 0 / 2 0 2 4 PL A N C H E C K S-2.0 RO O F F R A M I N G P L A N ROOF FRAMING PLAN SCALE : 1/4" = 1'-0" 901 E Myrtle St Unit# 2 - 1011181606/27/2024 2 3 8 CONT. REBAR PER PLAN MIN. 10 MIL VAPOR BARRIER OVER 2" CLEAN SAND 4" THICK BASEOF 1/2" OR LARGER CLEAN AGGREGATE TOP OF NATURAL GRADE OR COMPACT FILL MIN. 6" OVERLAP (U.N.O.) D= 1 8 " M I N . MI N . 7" PLYWOOD OR OSB PER PLAN EXTERIOR FINISH (SEE ARCHITECTURAL DETAILS FOR WATER RESISTANT BARRIER/WEEP SCREED) MI N . 8" INTERIOR FINISH 2x STUDS PER PLAN 2x PTDF SILL (USE 3x WHERE REQUIRED PER PLANS) w/ 5/8" DIA. ANCHOR BOLTS CONC. SLAB PER PLAN SLAB REINF. PER PLAN W=12" MIN. ALT.1 ALT.2 TOP OF NATURAL GRADE 3" CLR. COVERPOSSIBLE COLD JOINT SEE NOTES NOTES: 1.FOR TWO POUR CONSTRUCTION, SEE FOOTING COLD JOINT DETAIL. 2.MAXIMUM WATER CEMENT RATIO FOR SLAB CONCRETE SHALL BE W/C=0.45. 3.EMBEDMENT DEPTH, "D" SHALL BE MEASURED FROM THE LOWEST ADJACENT GRADE. TYPICAL EXTERIOR FOOTING FOR DUAL POUR, 7" EMBED. INTO THE 1st POUR START FROM THE COLD JOINT REBAR CONT. T&B (U.N.O.) PER PLAN CONC. SLAB PER PLAN TOP OF NATURAL GRADE OR COMPACT FILL D= 1 8 " M I N . 4" 2" M I N . (P E R A R C H . ) ISOLATE SLAB FROM STEM WALL (USE 1/2" FIBERBOARD MATERIAL) PORCH SLAB SLOPE TO DRAIN PER ARCH PLANS STUD BEYOND 3" CLR. COVER, TYP. W=12" NOTE: SEE DETAIL 1/SD1.0 FOR ADDITIONAL INFORMATION NOT SHOWN. 8" M I N . HOUSE TO PORCH TIE BEAM PER PLAN (WHERE OCCUR) 6" MIN. 6" M I N . 2 1 / 4 " 1-3/4" MIN. STANDOFF (SO) PER MANUF. de F F TO T A L R O D L E N G T H 2F MIN. SQUARE PAD SIZE PER SCHEDULE EXTERIOR CONDITION FINISH GRADE EXT. FTNG. REBAR PER PLAN CONC. SLAB & REINF. PER PLAN CENTERLINE OF A.B., POST & PAD FOOTING CL HOLDOWN PER PLAN TOP OF NATURAL GRADE OR COMPACT FILL 2 1 / 4 " 1-3/4" MIN. STANDOFF (SO) PER MANUF. de F F TO T A L R O D L E N G T H 2F MIN. SQUARE PAD SIZE PER SCHEDULE CONC. SLAB & REINF. PER PLAN CENTERLINE OF A.B., POST & PAD FOOTING CL HOLDOWN PER PLAN FTNG. REBAR PER PLAN ALT. EXTERIOR CURB CONDITION CL TO T A L R O D L E N G T H ALT. INTERIOR CURB CONDITION CL TO T A L R O D L E N G T H 1-3/4" MIN. SEE HOLDOWN MANUF. SPECS. FOR REQUIRED BOLT STANDOFF le SS T B E M B E D M E N T L E N G T H 3" CLR. COVER, TYP. PER PLAN FINISH GRADE FTG. REBAR PER PLAN CONC. SLAB & REINF. PER PLAN CENTERLINE OF A.B. & POST CL HOLDOWN PER PLAN 3" - 5 " (1)#4 BAR L=100" CENTERED AT SSTB PAB ANCHOR AT EXTERIOR FTG.PAB ANCHOR AT INTERIOR FTG.SB/SSTB ANCHOR BOLT HOLDOWN ANCHOR BOLT FOR MONOLITHIC CAST-IN-PLACE CONCRETE FOOTING PAB ANCHOR BOLT CURB CONDITION PAB ANCHOR BOLT HDU4 HDU5 HDU8 HDU11 HDU14 SLAB ON GRADE SSTB24 - SB5/8x24 EMBEDMENT (de) 11" TYPE PAB8 SLAB ON GRADE CURB/ STEMWALL SQUARE SSTB24 SSTB28 SB5/8x24 SB7/8x24 SB1x30 34" 45° 24 ANCHORBOLT (TYP.) OUTEREDGEOFCONCRETE(TYP.) 0° 135°/90°/45° 0° 45°45° 0° 135° 1.BOLTS SHALL BE SECURED IN PLACE PRIOR TO FOUNDATION POUR, U.O.N. 2.REFER TO MANUF. REQUIREMENTS, SPECIFICATIONS, AND APPLICABLE ICC-ESR REPORT. 3.POST TENSION CABLE MAY NOT BE COUNTED AS REQ'D HOLDOWN REBAR. 4.FOOTING TOP REBAR(S) MAY BE COUNTED AS REQ'D HOLDOWN REBAR(S). 5.HOLDOWNS MAY BE RAISED OFF MUD-SILL TO ACCOMMODATE MIS-LOCATED ANCHOR BY1-1/2" MAX. REFER TO MANUF. SPECS. 6.FOR ALL INFORMATION NOT SHOWN, REFER TO DETAIL1. 7.USE OF MULTIPLE WASHERS TO ACCOMPLISH TOTAL REQ'D THICKNESSIS NOT PER MITTED. 8.REBAR IS REQUIRED AT TOP OF STEM WALL FOUNDATION, BUT IS NOT REQUIRED FOR SLAB ON GRADE EDGE AND GARAGE CURB IF FOOTING WIDTH IS 12" OR GREATER. REFER TO MANUFACTURER FOR MIN. END DISTANCES. HOLDOWN SIMPSON TYPE CURB/ STEMWALL - SSTB28 - - - -- - SB5/8x24 SB5/8x24 SB1x30 - - - - - - - - - 24 PLAN VIEW OF SB/SSTB PLACEMENT INCONCRETE ANCHOR ORIENTATION 24 NOTES: 9.CURB SHALL BE 6" WIDE AT HTT5 AND HDU5 AND 8" WIDE AT HDU8 AND BEYOND SIMPSON "SSTB" ANCHOR BOLT SIMPSON "SB" ANCHOR BOLT SIMPSON "PAB" PRE-ASSEMBLED ANCHOR BOLT CORNER INSTALLATION (INSTALL WITH ARROW ON TOP OF THE BOLT ORIENTED AS SHOWN) NON-CORNER INSTALLATION (BOLT MAY BE INSTALLED @ 45° TO 135° AS SHOWN) CORNER INSTALLATION (INSTALL WITH ARROW ON TOP OF THE BOLT ORIENTED AS SHOWN) PAD SIZE (2F) 3" #4 CONT. 3" #4 CONT. 3" CLR. COVER, TYP. 3" CLR. COVER, TYP. HDU2 SSTB24 SB5/8x24-SB5/8x24 -- 12" MIN. 18 " M I N . ±6 " DE P T H T O M A T C H BO T T O M O F F T G . 8" M I N . PE R A R C H . 2" 6" MIN. PER ARCH. (1) 4# CONT. #4 VERT. @18" O.C. AT CENTER WHERE H >18" ±6 " DE P T H T O M A T C H BO T T O M O F F T G . FINISH GRADE (2)#5-TOP &BOTT. CONT. EXTEND MIN. 24" TO THE CONNECTING FOOTING OR TERMINATE W/ STANDARD HOOK AT FAR SIDE. 12" MIN. 12 " M I N . 3" CLR. COVER, TYP.3" CLR. COVER, TYP.(2)#5-TOP &BOTT. CONT. EXTEND MIN. 24" TO THE CONNECTING FOOTING OR TERMINATE W/ STANDARD HOOK AT FAR SIDE. WITH CURB BELOW GRADE H TIE BEAM NON-BEARING INTERIOR WALL CONC. SLAB PER PLAN USE SIMPSON 0.157"Ø PDPAWL SHOT PINS @ 16" O.C. OR APPROVED EQUIVALENT FOR NON-SHEAR WALLS, ICC-ES ESR-2138 2x STUDS PER PLAN INTERIOR FINISH NOTE: SEE DETAIL 1/SD1.0 AND NAILING & HARDWARE NOTE 10/S0.10 FOR ADDITIONAL INFORMATION NOT SHOWN. COLUMN & SPANDREL TIE BEAM & JOIST STIRRUP 6d bNOT E 1 135° SPANDREL & BEAM SUPPLEMENTARY TIE CROSS TIE db dbdb db db D D D 6db 3" MIN . 6db FOR #3 THRU #5 CROSS TIE 6d b F O R # 3 ~ # 5 12 d b F O R # 6 ~ # 8 12 d b DETAILING DIMENSION DETAILING DIMENSION D = 6db FOR #3 THRU. #8 BARS D = 8db FOR #9 THRU #11 BARS D = 10DB FOR #14 AND #18 BARS BEND BAR DIAMETER, D ALT. CROSS TIE END IN ALL CASES 6d b NOTE 1: BUT NOT LESS THAN 3" (SEISMIC HOOK) 90° STANDARD HOOK 180° STANDARD HOOK 6db 3" MIN . D D 2 1/2" MIN. BAR BENDING & STANDARD HOOKS STD. HOOK MI N . L A P 48 d b TYP. CONT. FTG. REBAR 0" 0" STD. HOOK TYP. CONT. FTG. REBAR 0" 0" 0" 0" MI N . L A P 4 8 d b MIN. LAP 48db T CONDITION CORNER CONDITION REINF. DETAILS AT FOOTING JUNCTIONS6 10 9 FTG. REINF. PER TYP. EXTERIOR FTG. DETAIL 12 " M I N . 7" M I N . 3" C L R . C O V E R TOP OF CONC. SLAB PER PLAN SLAB REINF. PER PLAN 0" 18" MIN. ADD #4@18" DOWELS (NOTE 1) 18" MIN. CONC. SLAB PER PLAN SLAB REINF. 7" M I N . 12 " M I N . 3" C L R . C O V E R 0" FTG. REINF PER PLAN FOR PAD FTG./ TYP. EXTERIOR FTG. DETAIL FOR CONT. FTG. COLD JOINT (ROUGHENED TO 1/4" AMPLITUDE) ANCHOR BOLT ANCHOR BOLT ADD #4@18" EXTERIOR FOOTING INTERIOR / PAD FOOTING NOTES: 1.DOWELS ARE REQUIRED WHERE ANCHOR BOLTS EMBEDMENT IS LESS THAN 7" IN FIRST POUR. 2.SLAB REBAR CAN BE BENT INTO THE FIRST POUR AND COUNTED TOWARDS REQUIRED DOWELS CROSSING COLD JOINT. 3.FOR BALANCE OF INFORMATION SEE TYPICAL FOOTING DETAILS. TYPICAL COLD JOINT IN FOOTING COLD JOINT (ROUGHENED TO 1/4" AMPLITUDE) 14 57 11 CONT. REBAR PER DETAIL 1.D MI N . E M B E D M E N T PE R 1 / S D 1 . 0 7" MI N . INTERIOR FINISH 2x STUDS PER PLAN PLYWOOD PER PLAN EXTERIOR FINISH (SEE ARCHITECTURAL DETAILS FOR WATER RESISTANT BARRIER/WEEP SCREED) 2x PTDF SILL CONC. SLAB PER PLAN TOP OF NATURAL GRADE OR COMPACT FILL SLAB REINF. PER PLAN 8" MI N . ISOLATE SLAB FROM STEM WALL w/ 1/2" FIBERBOARD MATERIAL 8" MI N . 4" MIN. PER PLAN 3" CLR. COVER, TYP. NOTE: SEE DETAIL 1/SD1.0 FOR ADDITIONAL INFORMATION NOT SHOWN. . EXTERIOR BEARING AT GARAGE CURB H PER ARCH. 6” WIDE CURB TYPICAL. INCREASE WIDTH TO 8” WHEN CURB IS GREATER THAN 12” IN HEIGHT OR MORE THAN ONE STORY ABOVE #4 VER. BAR AT 16” O.C. WHEN CURB IS TALLER THAN 12” CONC. SLAB PER PLAN DRIVEWAY SLAB CONC. CURB BEYOND REBAR CONT. T&B (U.N.O.) PER DETAIL 1. INTERIOR FINISH2x STUDS PER PLAN PTDF SILL & A.B. PER PLAN CONC. SLAB PER PLAN TOP OF NATURAL GRADE OR COMPACT FILL PER PLAN 4" ISOLATE SLAB FROM STEM WALL w/ 1/2" FIBERBOARD MATERIAL CONC. SLAB PER PLAN ISOLATE SLAB w/ 1/2" FIBERBOARD MATERIAL CONC. SLAB PER PLAN DRIVEWAY SLAB CONC. CURB BEYOND ISOLATE SLAB w/ 1/2" FIBERBOARD MATERIAL 3" CLR. COVER, TYP. SLAB REINF. PER PLAN SLAB REINF. PER PLAN D PE R D E T A I L 1/ S D 1 . 0 3" CLR. COVER, TYP. REBAR CONT. T&B (U.N.O.) PER DETAIL 1. PER PLAN 3" CLR. COVER, TYP. SLAB REINF. PER PLAN D PE R D E T A I L 1/ S D 1 . 0 SLAB REINF. PER PLAN HOUSE TO GARAGE SLAB GARAGE TO APRON - ALT 1 GARAGE TO APRON - ALT 2 NOTE: SEE DETAIL 1/SD1.0 FOR ADDITIONAL INFORMATION NOT SHOWN. NOTE: SEE DETAIL 1/SD1.0 FOR ADDITIONAL INFORMATION NOT SHOWN. NOTE: SEE DETAIL 1/SD1.0 FOR ADDITIONAL INFORMATION NOT SHOWN. PER PLAN D PE R D E T A I L 1/ S D 1 . 0 REBAR CONT. T&B (U.N.O.) PER DETAIL 1. MIN. 15 MIL VAPOR BARRIER (U.N.O) 4" GRAVEL OR AS RECOMMENDED BY GEOTECHNICAL REPORT (U.N.O.) TOP OF NATURAL GRADE OR COMPACT FILL GARAGE TO HOUSE/DRIVEWAY ISOLATED PAD FOOTING POST PER PLAN 3" CLR1'-8" SQUARE (MIN.) WIDTH PER PLAN 1" S T A N D O F F 7 1 / 4 " 3" C L R 1 1 / 2 " TY P . 6" MIN. SIDECOVER (TYP.) 2" T Y P . 11 1 / 2 " (M I N . ) DE P T H PE R P L A N 3" C L R 3" A A SECTION A-A WIDTH PER PLAN (8) #5 VERTICAL REBAR AT 8" ON CENTER #4 HORIZONTAL TIES @ 3" SPACING (SQUARE AND DIAMOND SHAPED TIES) 3" EXTENSION AT TIE HOOK (1/2" CLEAR FROM MPBZ) POST PER PLAN SIMPSON MPBZ SIMPSON MPBZ 1 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 03/20/2024 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 03/20/2024 02 / 2 0 / 2 0 2 4 PL A N C H E C K 2 03 / 1 1 / 2 0 2 4 PL A N C H E C K SD1.0 FO U N D A T I O N DE T A I L S 1 2 2 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SIMPSON STRAP PER SCHEDULE BEAM PER PLAN POST PER PLAN STRAP SCHEDULE STRAP END LENGTH A ST12 6" B ST18 9" C ST6215 8" - 2900# 5600# CAPACITYMARK EA. SIDE END VIEWISOMETRIC VIEW EN D LE N G T H EN D LE N G T H EN D LE N G T H NOTES: 1.ADD SHIMS EA. SIDE WHERE BEAM & POST WIDTH ARE DIFFERENT (MIN. 10D PENETRATION INTO MAIN MEMBER IS REQ'D, WHERE "D" IS THE SHANK DIAMETER OF NAIL) 2.PROVIDE FULL NAILING PER MANUF. REQUIREMENTS. 3.INCREASE STRAP LENGTH ON POST SIDE WHERE THERE IS DBL. TOP PLATE BETWEEN POST AND BEAM. SIMPSON STRAP PER SCHEDULE EN D LE N G T H BEAM/POST CONNECTION STRAP SCHEDULE END LENGTH A CS16 18" B (2) CS16 18" 1700# 3400# CAPACITYMARK END LEN G T H END L E N G T H 2ND STRAP (WHERE OCCURS) SIMPSON CS16 PER SCHEDULE AT CONDITION B, ADD 2x4x48" LONG MEMBER TO RECEIVE 2ND CS16 & NAIL. SISTER w/ 16d @ 4" O.C. STAGG. TO ROOF RAFTER ROOF RAFTER w/ E.N. PER PLAN DBL. TOP PLATE TYP. R/R STUD/POST SIMPSON STRAP FULL DEPTH BLK'G NOTES: 1.PROVIDE FULL NAILING PER MANUFACTURER TO PROVIDE STRAP FULL CAPACITY. 2.ROOF SHEATHING NOT SHOWN FOR CLARITY. DBL. T O P P L A T E TYP. R / R BLK'G DRAG AT REENTRANT CORNER NOTE: APPLICATION OF STRAP OVER PLYWOOD SHEATHING IS ACCEPTABLE. E.N. NOT REQUIRED OVER THE STRAP LENGTH WHERE STRAP APPLIED OVER PLYWOOD. DBL. ROOF RAFTERS OR BM. W/ EDGE NAILING TO ROOF SHEATHING RIDGE PER PLAN HANGER PER PLAN DBL. ROOF RAFTERS W/ EDGE NAILING TO ROOF SHEATHING. SIMPSON CS14x30"LONG STRAP FULLY NAILED PER MANUF. ROOF SHEATHING w/ EDGE NAILING TO DBL. ROOF RAFTERS DRAG DETAIL AT FLUSH RIDGE CONNECTION E.Q.E.Q. STRAP SCHEDULE SIMPSON STRAP MIN BEAM/JOIST WIDTH END LENGTH A (1) CS16 2x 18" (2) CS16 2-2x OR 3x 18" C 24" CMST14 4x 36" 1700# 3400# 4585# 6490# CAPACITY TO RECEIVE STRAP MARK D B FLUSH BEAM CONDITION FLUSH BEAM/JOIST(S) W/ LINE OF E.N. PER PLAN POST OR MULTISTUD PER PLAN DBL. TOP PL. CONT. BEAM/BLK'G PER FRAMING PLAN EQ.EQ. STUD SIMPSON STRAP PER SCHEDULE NOTE: PROVIDE FULL NAILING PER MANUF. TO DEVELOP FULL CAPACITY OF THE STRAP. DRAG STRAP AT WALL END DROP BEAM CONDITION DROP BEAM PER PLAN POST OR MULTISTUDS PER PLAN SIMPSON STRAP PER SCHEDULE EQ.EQ. DBL. TOP PL. STUD ALT. STRAP LOCATION 2-2x OR 3x(2) CS14 B.N.ROOF SHEATHING 2x R.R. OR L.V.L. RIM PER PLAN SIMPSON CLIP PER SHEAR WALL SCHEDULE (@48" O.C. MAX.) E.N. SHEAR PANEL PER PLAN ALT. LOCATION OF SIMPSON A35/LTP4 ROOF SHEATHING 2x R.R. OR L.V.L. RIM PER PLAN 2x STUD WALL2x STUD WALL ALIGNED CONDITION OFFSET CONDITION INTERIOR SHEAR TRANSFER AT ROOF RAFTER EXTERIOR PLYWOOD SHEAR PANEL TYPE 2 ENTIRE WALL FROM LOW ROOF TO HIGH ROOF OVER ENTIRE LENGTH OF WALL U.N.O. B.N. ROOF SHEATHING 2x R/R OR TOP CHORD OF TRUSS EXTERIOR PLYWOOD APPLY PRIOR TO LOW ROOF INSTALLATION. BEAM PER PLAN B.N. EXTERIOR PLYWOOD SHEAR PANEL TYPE 2 FROM LOW ROOF TO HIGH ROOF OVER ENTIRE LENGTH OF THE WALL U.N.O. ROOF SHEATHING 2x R/R OR TOP CHORD OF TRUSS 2x LEDGER MATCHING R.R. SIZE U.N.O. 2x STUD PER PLAN E.N. H2.5A @ 48" O.C. FROM LEDGER TO STUDS. SLIT THE PLYWOOD TO INSTALL. 16d @ 6" O.C. U.N.O. 2x BLOCKING (NOTE 1) INTERIOR SHEAR PANEL PER PLAN 2x BLK'G. w/16d @ 6" O.C. U.N.O. TO LEDGER 8d COMMON PER SHEAR WALL SCHEDULE. (@ 4" O.C. MAX. U.N.O.) B.N. EXTERIOR PLYWOOD SHEAR PANEL TYPE 2 FROM LOW ROOF TO HIGH ROOF OVER ENTIRE LENGTH OF THE WALL U.N.O. ROOF SHEATHING 2x STUD PER PLAN H2.5A @ 48" O.C. FROM LEDGER TO STUDS. SLIT THE PLYWOOD TO INSTALL. CONDITION I-SHEAR PANEL AT INTERIOR SIDE CONDITION III-SHEAR TRANSFER AT BEAM E.N. 16d's @ 6" O.C. U.N.O. 2x STUDS H2.5A @ 48" O.C. FROM LEDGER TO STUDS. SLIT THE PLYWOOD TO INSTALL 2x LEDGER MATCHING R.R. SIZE U.N.O. EXTERIOR PLYWOOD SHEAR PANEL PER PLAN. INSTALL PRIOR TO LOW ROOF CONSTRUCTION. CONDITION II-SHEAR PANEL AT EXTERIOR SIDE NOTE 1: INSTALL HARDWARE AT EXTERIOR WALLS PRIOR TO BLOCKING INSTALL SHEAR TRANSFER AT HIGH ROOF TO LOW ROOF F.H. BLOCKING @48" O.C. F.H. BLOCKING @48" O.C. SHEAR PANEL PER PLAN FULL HEIGHT BLK'G. ROOF SHEATHING SIMPSON A35 PER SHEAR WALL SCHEDULE MAX.48" O.C. SIMPSON H2.5A @ 48" O.C. U.N.O. DBL. TOP PLATE OR BM. PER PLAN ROOF RAFTERS PER PLAN POST/STUD VAULTED CEILING CONDITION B.N. E.N. 2x CONT. FASCIA w/ 2-16d FACE NAILS TO EACH RAFTER SHEAR TRANSFER AT R/R PER. TO EXTERIOR WALL SIMPSON H2.5A @ 48" O.C. U.N.O. DBL. TOP PLATE OR BM. PER PLAN ROOF RAFTERS PER PLAN POST/STUD SIMPSON A35 PER SHEAR WALL SCHEDULE MAX. 48" O.C. CJ w/ 8-16d FACE NAILS TO R/R PER PLAN. SHEAR PANEL PER PLAN w/ CEILING JOISTS CONDITION FULL HEIGHT BLK'G. ROOF SHEATHING B.N. E.N. 2x CONT. FASCIA w/ 2-16d FACE NAILS TO EACH RAFTER 18" MAX.24" MIN. B.N. (2) 16d's TO EA. OUTRIGGER SHEAR WALL PER PLAN BALLOON FRAMED STUDS TYPICAL ROOF RAFTER PER PLAN (2) 16d's PER CONNECTION 2x4 FLAT OUTRIGGER @ 24" O.C. ROOF SHEATHING2x FLAT BLOCKS W/ 16d's @ 4" O.C. TO PLATE BELOW. 2x FASCIA BOARD CONDITION I - TRANSFER THROUGH BLOCKING E.N. SHEAR TRANSFER R/R PARALLEL TO EXTERIOR WALL TYPICAL ROOF RAFTER PER PLAN (2) 16d's PER CONNECTION 2x4 FLAT OUTRIGGER @ 24" O.C. ROOF SHEATHING 18" MAX.24" MIN. B.N. (2) 16d's PER CONNECTION. SHEAR WALL PER PLAN BALLOON FRAMED STUDS 2x FLAT BLK'G 2x FASCIA BOARD CONDITION II - TRANSFER THROUGH R.R. 16d's @ 4" O.C. 2x R.R. ADJACENT TO WALL NOTCHED AT OUTRIGGERS (DO NOT OVER-CUT) E.N. B.N. ALT 1: STRAP SPLICE SIMPSON STRAP PER SCHEDULE EQ.EQ. ALT 2: LAP SPLICE LAP SPLICE LENGTH PER SCHEDULE 2x STUDS (PLACE AT JOINT TYP.) 16d SEE SCHEDULE FOR REQ'D # 2x STUDS (PLACE AT JOINT TYP.) 2 1/2" (MIN.) 16d NAIL PATTERN TOP PLATE (PLAN VIEW @ LAP ZONE) NOTES: 1.NAILING SHOULD BE PER MANUFACTURER TO DEVELOP 100% CAPACITY OF THE STRAP. 2.FOR NAIL SIZE AND SPACING OUTSIDE THE LAP LENGTH REFER TO NAILING SCHEDULE OF GENERAL NOTES. 3.STAGGER NAILS AND SPACE EVENLY TO AVOID SPLITTING. TOTAL STRAP LENGTH TOP PLATE SPLICE 2x STUDS (PLACE AT JOINT TYP.)2x STUD (PLACE AT JOINT TYP.) SIMPSON STRAP PER SCHEDULE EQ.EQ. EQ.EQ. HIP CONDITION VALLEY CONDITION SIMPSON STRAP PER SCHEDULE NO. OF 16d LAP SPLICE LENGTH SIMPSON STRAP A 18 4'-0"ST22 B 28 4'-0"ST6224 C 40 6'-0" 42 ST6236 MARK E 8'-0"MSTC52 D 62 8'-0"MSTC37 (NOTE 1) SPLICE SCHEDULE @ EACH LAP (NOTE 2) LAP SPLICE STRAP SPLICE 1 2 3 4 5 6 8 BM. PER PLAN ST18 AT POST TO BEAM BELOW, TYP OF (2) 16d NAILS @ 4" O.C. STAGGERED EACH SIDE KING POST BM. PER PLAN 2x KING STUD AT EITHER SIDE OF POST SIMPSON ST18 EACH SIDE OF KING POST TO BEAM. ALT1: w/ KING STUD ALT 2: w/ STRAPS KING POST KING POST CONNECTION NOTES: - ROOF FRAMING NOT SHOWN FOR CLARITY - PROVIDE FULL HEIGHT POST PER PLAN WHERE NO BEAM BELOW OCCURS STRAP KING STUDS ABOVE & BELOW WITH (1)CS16 (MIN. 18" END LENGTH) EA. STUD - AT LOCATIONS WHERE KING POST IS BEARING ON SOLE PLATE; PROVIDE SIMPSON A35 EACH SIDE OF POST 7 COLLAR TIE CONNECTION DETAIL EQ EQ H E.N.E.N. SIMPSON ST22 STRAP @ EACH R.R. 6-16d FACE NAILS RAFTER TIES/ CEILING JOIST @ 16" O.C. (*) 2x4 COLLAR TIE @ 48" O.C.6-16d FACE NAILS AT EA. ENDS H / 3 L=14'-0" MAX. B.N.B.N. ROOF SHEATHING NOTE: (*) RAFTER TIES SHALL BE INSTALLED AT LOWER THIRD OF THE ROOF SYSTEM AND CAN BE USED AS CEILING JOISTS AS SHOWN. NOTIFY E.O.R. WHERE CEILING JOISTS ARE CONFLICTED WITH RAFTER TIES 2X RIDGE BOARD PER PLAN 2X R.R. PER PLAN REFER TO DETAIL 4/S-D2.0REFER TO DETAIL 4/S-D2.0 COLLAR TIE CONNECTION DETAIL L=22'-3" MAX. EQ EQ H E.N.E.N. B.N.B.N. SIMPSON ST22 STRAP @ EACH R.R. 2x R/R PER PLAN PLWD. SHT'D. W/E.N. 2x RIDGE BOARD PER PLAN REFER TO DETAIL 4/SD2.0 2x COLLAR TIE/CEILING JOIST PER PLAN. 6-16d COMMON FACE NAILS6-16d COMMON FACE NAILS 2x COLLAR TIE/CEILING JOIST PER PLAN. 12" LAP MIN. W/ (8)16d 2x4 COLLAR TIE @ 48" O.C.6-16d FACE NAILS AT EA. ENDS H / 3 A35 EACH CEILING JOIST 9 10 11 PROVIDE SOLID SHIM UNDER AND AT THE SIDE AS REQUIRED SIMPSON MSTC 28, U.N.O. POST PER PLAN w/ SIMPSON CCQ OR CC EQ.EQ. SIMPSON ECCQ OR SIMILAR POST PER PLAN w/ SIMPSON ECCQ OR ECC END CONDITION MIDDLE CONDITION (EQUAL BEAM HEIGHTS) MIDDLE CONDITION (UNEQUAL BEAM HEIGHTS) LARGER BEAM SMALLER BEAMFIRST BEAM SECOND BEAMBEAM EQ.EQ. NOTES: 1.BEAMS SHALL BE ALIGNED TO RECEIVE STRAP. ALTERNATIVELY STRAP MAY BE PLACED OVER THE TOP OF BEAM. 2.SHIM TIGHT WHERE REQUIRED. 3.STRAP NOT REQUIRED AT INTERIOR SUPPORT OF CONTINUOUS BEAMS. BEAM TO POST CONNECTION ALT. CONDITION SIMPSON ECCL OR SIMILAR BEAM POST PER PLAN WOOD BEAM SEE PLAN SIMPSON ECCLQ/CCCQ/CCT OR SIMILAR BEAM POST PER PLAN BEAM WOOD BEAM SEE PLAN EQ.EQ.SIMPSON MSTC 28, U.N.O. 12 SHEAR PANEL AT GARAGE NOTE: (*) EMBEDMENT SHOULD BE SATISFY HOLDOWN REQUIREMENT PER DETAIL 10/SD1.0, DEEPEN FOOTING AS REQUIRED. (**) CONTRACTOR TO VERIFY CURB DIMENSIONS PIOR TO INSTALL STRAP OR HOLDOWN A35 CLIPS PER SW SCHED. 2-2X TOP PLATE SHEATHING ENTIRELY ABOVE HEADER, MATCH SHEAR WALL TYPE PER PLAN (MIN. TYPE 1) (U.N.O) NAIL KING STUD WHERE OCCURS TO POST/ TRIMMER w/ 16d @ 6" O.C. INSTALL ST6236 ON BOTH SIDES OF EACH POST (STAGGERED AT FRONT & BACK) FASTENING ALL HOLES w/ 16d (U.N.O) 3-16d CONT. HDR PER PAN NAIL KING STUD WHERE OCCURS TO POST/ TRIMMER w/ 16d @ 6" O.C. BOUNDARY NAIL SHEAR WALL SHEATHING PER PLAN OPPOSITE POST w/ STRAP AS OCCURS PER PLAN A.B. PER SHEAR WALL SCHED. CONT. HDR ABOVE HOLD DOWN PER PLAN ST6236 STRAP AS OCCURS, SEE SIMPSON CATOLOG FOR STRAP INFO. AND NAILING PATTERN MIN. 5.5" 4X OR 6X POST/ TRIMMER PER PLAN SHEAR WALL SHEATHING PER PLAN OPPOSITE POST w/ STRAP AS OCCURS PER PLAN 2X P.T. SILL PLATE TOP OF CONC. SLAB OR CURB 5/8" ROD DIAMETER A.B. BOLTS PER SHEAR WALL SCHEDULED (MIN. 2) STRAP-TIE/ HOLDOWN PER PLAN (**) ELEVATION VIEW PLAN VIEW (* ) GARAGE OPENING 13 FLUSH BEAM SIMPSON A34 (TYP.) MULTIPLE STUDS (SISTER w/FACE NAILS PER NAILING SCHEDULE) OR POST, PER PLAN DBL. TOP PLATES SILL/SOLE PLATE FRONT VIEW SIDE VIEW CONT. FLUSH BEAM WHERE OCCURS FLUSH BEAM TO DBL TOP PLATES CONNECTION14 SHEAR TRANSFER DETAIL ROOF SHEATHING. PER PLAN (SEE S-0.10) BN. ROOF RAFTERS PER PLAN E.N. E.N. 2X BLK'G W/E.N. W/16d @ 6"O.C. TO BEAM CL'G BEAM PER PLAN ROOF SHEATHING. PER PLAN (SEE S-0.10) APPROVED SLOPED HANGER (SIMPSON LRUZ IN LIEU OF PLAN SPEC) ROOF RAFTERS PER PLAN CL'G JOIST W/ APPROVED HANGER PER PLAN (WHERE OCCURS) 2X CRIPPLE WALL SHEAR PANEL MIN. TYPE 1 DBL TOP PLATE 2X SILL PLATE W/ 16d @ 6" O.C. TO BEAM E.N. OVER FRAMING. (REFER TO 8/S-0.20) 15 BE A M D E P T H PE R P L A N NO T C H T O M A T C H RO O F S L O P E , (D O N O T O V E R C U T ) NOTCH @ BEAM DBL. TOP PLATES, BEAM OR POST BEAM PER PLAN TO BE NOTCHED AS SHOWN A34 EACH SIDE OF BEAM TO TOP PLATES (2) TOTAL HEADER WHERE OCCURS 16 17 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 02/29/2024 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 02/29/2024 02 / 2 0 / 2 0 2 4 PL A N C H E C K SD2.0 ST R U C T U R A L DE T A I L S 1 1 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 02/29/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 #4 TWO PIECE ASSEMBLY#4 SINGLE PIECE HOOP - 3 - 4 1 3 6 2 4 5 GRADE BEAM ELEVATION AT 18" AND 24" WALL MODELSGRADE BEAM SECTION AT ANCHOR REINFORCEMENTCLOSED TIE ANCHOR REINFORCEMENT GRADE BEAM ELEVATION AT 12" WALL MODEL GRADE BEAM SECTION AWAY FROM ANCHOR REINFORCEMENT WSWH-AB ANCHOR GRADE BEAM REINFORCEMENT AND DESIGN MOMENTS WSWH GRADE BEAM ANCHOR REINFORCEMENT HIGH STRENGTH STRONG-WALL® WOOD SHEARWALL WIDTH (in.) ANCHOR MODEL NO. ANCHOR DIAMETER (in.) ANCHOR REINFORCEMENT FOR WIND AND SEISMIC3,8,9 AMPLIFIED LRFD APPLIED DESIGN SEISMIC MOMENT (ft.-lbs.)4,5,6,7 STANDARD STRENGTH WSWH-AB1 HIGH STRENGTH (HS) WSWH-AB1HSSTANDARD STRENGTH WSWH-AB1 HIGH STRENGTH (HS) WSWH-AB1HS 2 - 1 - 2 - 1 - - 3 - 4 ST R O N G - W A L L W S W H AL T E R N A T E A N C H O R A G E D E T A I L S EN G I N E E R E D D E S I G N S ® WSWH1.1 N.T.S. 03-16-2021 0 10 - 1 2 - 2 0 2 0 FI R S T R E L E A S E - 2 0 1 8 I B C 1 03 - 1 6 - 2 0 2 1 20 2 1 I B C R E V I S I O N S SI M P S O N S t r o n g - T i e , C o . I n c . TH E R E I S N O E Q U A L TH E R E I S N O E Q U A L . 02/29/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 ® MODEL NO.W (in.)H (in.)ANCHOR BOLTS TOTAL WALL WEIGHT (lb.)QUANTITY DIA. (in.) ® ® ® ® GARAGE HEADER ROUGH OPENING HEIGHT MODEL NO.TRIMMED PANEL HEIGHTH CURB ROUGH OPENING HEIGHT ® GARAGE WALL OPTION 1 GARAGE WALL OPTION 2 ® WSWH-TP CONNECTION MODEL NO.FASTENER QUANTITY SWS16150 SDS25600 SECTION VIEW 2X6 OR WIDER FRAMING EDGE DISTANCE FOR SCREWS ® ® ® PLAN VIEW SDS SCREW SPACING QTY. OF SDS14"x6" SCREWS REQ'D. SECTION ® · · · · 1" TO 4" SHIM BLOCK418" TO 12" SHIM BLOCK ® CRIPPLE WALL ® ® ® ® ® ® SECTION 4x FRAMING SECTION 6x FRAMING STRONG-WALL® HIGH STRENGTH WOOD SHEARWALL MODELS 1STRONG-WALL® WSWH MODELS 2SINGLE STORY WSWH ON CONCRETE 4STANDARD INSTALLATION BASE CONNECTION 6TOP CONNECTION 9TOP OF WALL HEIGHT ADJUSTMENTS 5WOOD FLOOR SYSTEM BASE CONNECTION 7BACK-TO-BACK TOP CONNECTION 10TRIM ZONE AND ALLOWABLE HOLES 3ALTERNATE WSWH GARAGE FRONT OPTIONS 8RAKE WALL 11NOTES ® 6 - 4 - 5 - 6 - 6 - 4 - 4 - ALLOWABLE SMALL HOLES FACE AND EDGE DRILL ZONES ALLOWABLE LARGE HOLES IN ADDITION TO ALLOWABLE SMALL HOLES · · · · · ● ● ● WSWH-TP CONNECTION MODEL NO.FASTENER QUANTITY SWS16150 SDS25600 ® SECTION 8x FRAMING ST R O N G - W A L L W S W H FR A M I N G D E T A I L S EN G I N E E R E D D E S I G N S ® WSWH2 N.T.S. 03-16-2021 0 11 - 2 0 - 2 0 2 0 FI R S T R E L E A S E - 2 0 1 8 I B C 1 03 - 1 6 - 2 0 2 1 20 2 1 I B C R E V I S I O N S SI M P S O N S t r o n g - T i e , C o . I n c . TH E R E I S N O E Q U A L TH E R E I S N O E Q U A L 02/29/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK A.01 CAL GREEN CODE (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 x Contractor x Contractor x Contractor x Architect x Engineer x Architect x Architect x x x Architect x Architect x Architect x x Owner x Architect x Contractor x Contractor x Contractor x Contractor x Contractor x 901 E Myrtle St Unit# 2 - 1011181606/27/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK A.02 CAL GREEN CODE (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 x Contractor x Contractor x Contractor x Architect x Engineer x Architect x Architect x x x Architect x Architect x Architect x x Owner x Architect x Contractor x Contractor x Contractor x Contractor x Contractor x 901 E Myrtle St Unit# 2 - 1011181606/27/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM T24.1 TITLE 24 (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM T24.2 TITLE 24 (CONT.) (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 1 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM T24.3 TITLE 24 (CONT.) (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 W GG W 5% MIN. 5% MIN. 2% 5% MIN. 5%MI N . 5%MIN . 2% MIN. 2% MIN. 2% 2% 2% 2% 5% MIN. 2% 2% MIN. 2% 5% MIN. 2% MIN. 5%MI N . 5%MI N . PL 56.58' PL 1 0 0 . 0 2 ' PL 64.87' PL 14.28' PL 35.46' PL 42.84' (E) TO CENTER LINE 30 ' - 0 " (E) 2-CAR GARAGE 420 SF SINGLE FAMILY RESIDENCE 1044 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 TO CENTERLINE 10 ' - 0 " (E) TOCENTER LINE 30'-0" (E) PROCH STREET CURB & GUTTER CENTERLINE OF STREET CENTERLINE OF STREET (E) 22 ' - 6 " DISTANCE 6' - 0 " F.S.D 3' - 0 " F.S.D 3' - 0 " (N) ADU 1-CAR GARAGE 305 SF F.S.L (N) DETACHED ADU -UNIT 2 791 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 F.S.D 3' - 0 " F.S.D 3' - 0 " 35 ' - 1 0 " DISTANCE 6' - 0 " (N) WALKWAY E MYRTLE ST S S T A N D A R D A V E ADU SETBACK 5'-0" ALLEY A D.01 HIGH POINT FLOW LINE FLOW LINE OVER FLOW OVER FLOW WM-08 FLOW LINE SE-6 SE-6 SE-6SE-6 SE-6 SE-6 RE Q . S E T B A C K 4' - 1 0 " DISTANCE 5'-1"22'-3" 15 ' - 0 " 41 ' - 0 " A D.01  5% MIN 5% MIN BUILDING DRAINAGE DETAIL NOT TO SCALE A MI N . 8 " FF PAD WEEPSCREEDPER PLAN WIDTH SE-6: PLACE GRAVEL BAG BERM BMP PER CASQA STANDARDS. DETAIL HEREON. WM-8: IMPLEMENT CONCRETE WASHOUT AREA PER CASQA STANDARDS. DETAIL HEREON. EROSION CONTROL CONSTRUCTION NOTES SECTION A -A FINISH GRADE FINISH GRADE TWO (2) BAGS HEIGHT TWO (2) BAGS WIDE A A SE-6: GRAVEL BAG DETAIL NTS GRAVEL BAG BERM SECTION B-B 3 . 0 ' LATH & FLAGGING ON ALL SIDES (WATERPROOFED) VA R I E S 10' MIN. GRAVEL BAG BB 10 MIL. PLASTIC LINING N SCALE: 1"=10' 010'20'20'10'5'15' STREET CENTER LINE FLOW LINE EXISTING SLOPE LEGEND: PROPERTY LINE LANDSCAPE AREA SLOPE SURFACEX% IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK D.01 DRAINAGE PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 PREFABRICATED OR SPECIALTY ITEMS AND THEIR COMPONENTS, WHICH ARE INDICATED BY THE STRUCTURAL DRAWINGS TO BE DESIGNED BY OTHERS, MAY BE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER OF RECORD FOR REVIEW AS A DEFERRED SUBMITTAL PROVIDED THAT SUCH SUBMITTAL IS AUTHORIZED BY THE BUILDING DEPARTMENT. DEFERRED SUBMITTALS REQUIRED TO BE SUBMITTED TO THE STRUCTRURAL ENGINEER OF RECORD SHALL INCLUDE BUT NOT BE LIMITED TO: A. MECHANICAL, ELECTRICAL AND PLUMPING EQUIPMENT B. SELF SUPPORTING, PRE-MANUFACTURED STAIR ASSEMBLY C. PREFABRICATED ROOF & FLOOR TRUSSES D. HVAC STRUCTURAL SUPPORT REQUIREMENTS E. AWNINGS, SIGNAGE, FASCIAS, ETC. F. FIRE SPRINKLERS G. CONTINUOUS TIE DOWN SYSTEM H. CONCRETE MIX DESIGN CONTINUOUS AND PERIODIC SPECIAL INSPECTION IS REQUIRED FOR THE WORK AS DESCRIBED IN IBC/CBC CHAPTER 17, SEE INSPECTION SCHEDULE BELOW, ONLY CHECKED ITEMS ARE REQUIRED. APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OF FAILURE TO COMPLY WITH THE PLANS OR SPECIFICATIONS, ANY DETAIL THAT FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE STRUCTURAL ENGINEER FOR INTERPRETATION OR CLARIFICATION. CONTINUOUS SPECIAL INSPECTION PER AWS D1.1 IS REQUIRED FOR ALL STRUCTURAL STEEL WELDING, EXCEPT FOR SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE. STRUCTURAL WOOD, PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEARWALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING OF COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM, INCLUDING WOOD SHEARWALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, SHEAR PANELS, AND HOLD-DOWNS, EXCEPTION: SPECIAL INSPECTION IS NOT REQUIRED FOR WOOD SHEARWALLS, SHEAR PANELS AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING AND OTHER FASTENING TO OTHER COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM, WHERE THE FASTENER SPACING OF THE SHEATHING IS MORE THAN 4 INCHES ON CENTER. INSPECTIONS SHALL BE PERFORMED BEFORE COVERING. 1. 1. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. SHOP DRAWINGS ARE REVIEWED ONLY FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DRAWINGS. DESIGN ACCURACY OF SUCH PRODUCT, DIMENSIONS AND QUANTITY OF THE PRODUCT IS NOT REVIEWED BY EOR. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DRAWINGS SHALL BE CLOUDED ANY OF THE AFOREMENTIONED SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW UNLESS SPECIFICALLY NOTED ACCORDINGLY. 3. THE SHOP DRAWINGS DO NOT SUPERSEDE OR REPLACE THE ORIGINAL CONTRACT DRAWINGS. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN APPROPRIATELY REGISTERED ENGINEER. ENGINEERING SYSTEM SOLUTIONS SHALL NOT BE RESPONSIBLE FOR THE ADEQUACY OF ENGINEERING DESIGNS PERFORMED BY OTHERS. 4. SHOP DRAWINGS SHALL REFERENCE DATE AND DELTA (IF ANY) OF CONTRACT DRAWINGS.5. ALL DEFERRED SUBMITTALS SHALL INCLUDE CALCULATIONS AND DRAWINGS PREPARED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AND STAMPED BY AN APPROPRIATELY LICENSED PROFESSIONAL ENGINEER. SUBMITTALS SHALL SHOW LOCATION AND MAGNITUDE OF LOADS, SIZE AND CONFIGURATIONS OF MEMBERS, AND COMPATIBILITY WITH THE PRIMARY STRUCTURAL SYSTEM. 2. CONTRACTOR RESPONSIBLE FOR CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THIS STATEMENT OF SPECIAL INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH A SYSTEM OR COMPONENT PER SEC 1704.4. WHERE FABRICATION OF MEMBERS AND ASSEMBLIES IS PERFORMED ON THE PREMISES OF A FABRICATOR'S SHOP, SPECIAL INSPECTION OF THE FABRICATED ITEMS SHALL BE REQUIRED BY THIS SECTION, UNLESS THE FABRICATOR IS REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION, APPROVAL SHALL BE BASED UPON REVIEW OF THE FABRICATOR'S WRITTEN PROCEDURAL AND QUALITY CONTROL MANUALS AND PERIODIC AUDITING OF FABRICATION PRACTICES BY AN APPROVED SPECIAL INSPECTION AGENCY, AT COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE OF VERIFYING APPROVAL OF FABRICATOR. 2. 3. 4. 5. 6. SUBMITTALS AND SHOP DRAWINGS STATEMENT OF SPECIAL INSPECTION: THE SPECIAL INSPECTOR SHALL BE A QUALIFIED INDIVIDUAL WHO WILL DEMONSTRATE COMPETENCE, AND KNOWLEDGE TO THE BUILDING OFFICIAL, FOR THE SPECIFIC TYPE OF SPECIAL INSPECTION REQUIREMENT REQUIRED PER SCHEDULE BELOW. 7. WOOD SPECIAL INSPECTIONS SHALL BE PER CBC SECTION 1705.5.8. SPECIAL INSPECTIONS FOR WIND AND SEISMIC RESISTANCE SHALL BE PER SECTION 1705.11 AND 1705.12 RESPECTIVELY. 9. REQ'D(?) STATEMENT OF SPECIAL INSPECTIONS (ONLY INDICATED ITEMS ARE REQUIRED) INSPECTION ITEMS SPECIAL INSPECTIORS (NAME, PHONE#, REGISTRATION#) STRUCTURAL STEEL (1705.2.1) STEEL FRAME JOINT DETAILS COLD-FORMED STEEL DECK (1705.2.2) OPEN-WEB STEEL JOISTS AND JOISTS GIRDERS (1705.2.3) REINFORCING STEEL AND PRE-STRESSING STEEL TENDONS SHOTCRETE (CURING TEMPERATURE, DESIGN MIX, PLACEMENT, STRENGTH ETC. PER TABLE 1705.3) COLD-FORMED STEEL TRUSSES SPANNING >= 60 FT CONCRETE CONSTRUCTION (DESIGN MIX, FORMWORK, PLACEMENT, ETC. PER TABLE 1705.3) (SEE 1705.3 EXCEPTIONS) STRUCTURAL WELDING/REBAR WELDING ALL MASONRY CONSTRUCTION (1705.4) WOOD FOR HIGH LOAD DIAPHRAGMS (1705.5.1) METAL-PLATE-CONNECTED WOOD TRUSSES SPANNING >=60 FT SOILS (EXCAVATION, FILL, ETC. PER 1705.6) (SEE 1705.6 EXCEPTIONS) DRIVEN PILES PER 1705.7 CAST IN PLACE PILES PER 1705.8 HELICAL PILE FOUNDATIONS PER 1705.9 ERECTION OF PRE- CAST CONCRETE MEMBERS BOLTS INSTALLED IN CONCRETE HIGH STRENGTH BOLTING/MATERIAL VERIFICATION WOOD DIAPHRAGM AND SHEAR WALLS* *: FOR SPECIAL INSPECTION OF WOOD DIAPHRAGMS AND SHEAR WALLS, CONTACT EOR FOR SCHEDULE. EPOXY/ POST INSTALLED ANCHORS YES 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/26/2023 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/26/2023 GE N E R A L N O T E S & RE Q U I R E M E N T S S-0.11 & SO I L R E P O R T 901 E Myrtle St Unit# 2 - 1011181606/27/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/26/2023 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/26/2023 SO I L R E P O R T S-0.12 901 E Myrtle St Unit# 2 - 1011181606/27/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/26/2023 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/26/2023 SO I L R E P O R T S-0.13 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 W/H AT T I C HP R GD J RE F . DW DW AT T I C HP R R R R R R R R R R R R R R R R R R J GD 1. ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. 2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR OR OCCUPANT SENSOR PROVIDED THE OCCUPANT SENSOR IS INITIALLY PROGRAMMED LIKE A VACANCY SENSOR (MANUAL-ON OPERATION). 150(K) 2I 3. LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL THE FOLLOWING: LISTED FOR ZERO CLEARANCE INSULATION, LABELLED THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH A LEAKAGE LESS THAN 2.0CFM AT 75 PASCALS, SEALED WITH A GASKET OR CAULK, ALLOW REPLACEMENT AND MAINTENANCE TO BE READILY ACCESSIBLE FROM BELOW THE CEILING WITHOUT CUTTING HOLES IN THE CEILING, SHALL NOT CONTAIN SCREW BASE SOCKETS, AND SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH JA8. 4. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON AND ONE OF THE FOLLOWING: CONTROLLED BY PHOTOCELL AND MOTION SENSOR, PHOTO CONTROL AND AUTOMATIC SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY MANAGEMENT CONTROL SYSTEM. CBEES 150(K)3 5. NO CONTROLS SHALL BYPASS A DIMMER OR VACANCY SENSOR FUNCTION WHERE THAT DIMMER OR VACANCY SENSOR HAS BEEN INSTALLED TO COMPLY WITH 150.0(K). 1. ALL WORK SHALL BE IN FULL ACCORDANCE WITH ALL APPLICABLE AND REGULATIONS OF GOVERNING AGENCIES AND SHALL COMPLY WITH THE REQUIREMENTS OF THE SERVING POWER AND TELEPHONE COMPANIES. 2. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52. 3. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC ARTICLE 210-70. 4. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8 5. ELECTRICAL SERVICE SIZE: 225 AMPS, MIN. 6. GFCI OUTLETS ARE REQUIRED: FOR ALL KITCHEN RECEPTACLES THAT ARE DESIGNED TO SERVE COUNTERTOP SURFACES, DISHWASHERS, BATHROOMS, IN UNDER-FLOOR SPACES OR BELOW GRADE LEVEL, IN UNFINISHED BASEMENTS, CRAWL SPACE LIGHTING OUTLETS, IN EXTERIOR OUTLETS, WITHIN 6’ OF A LAUNDRY/UTILITY/WET BAR SINK, LAUNDRY AREAS, AND IN ALL GARAGE OUTLETS INCLUDING OUTLETS DEDICATED TO A SINGLE DEVICE OR GARAGE DOOR OPENER. (CEC 210.8). KITCHEN AND LAUNDRY RECEPTACLE SHALL BE BOTH AFCI AND GFCI PROTECTED. 7. OUTDOOR RECEPTACLES SHALL BE LOCATED PER CODE MINIMUM REQUIREMENTS, AND AFCI, GFCI, W.R., AND W.P. WITH A BUBBLE COVER. 8. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO REINFORCING BAR IN CONCRETE FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN. 9. RECEPTACLES AND WALL SWITCHES SHALL BE INSTALLED NOT LESS THAN 15" MEASURED FROM BOTTOM OF IT TO FINISH FLOOR AND LOCATED NO MORE THAN AT 48" MEASURED FROM TOP OF RECEPTACLES AND WALL SWITCHES TO FINISH FLOOR IN VERTICAL DIRECTION, UNLESS OTHERWISE NOTED. ( CBC 1136 ). 10. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24". BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE AND INTERCOM OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY) 11. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION 12. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50% 13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR OBSTRUCTION. 14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO EXCEED 50 DBA (55 DBA WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION 10.26.045 OF THE LOCATION OF MEASUREMENTS TO BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY 15. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE REPLACEMENT 16. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED. 17. PROVIDE RECEPTACLES AT 6' FROM CORNERS, 12' ON CENTER. 18. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM. 19. ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUIT IN KITCHEN, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECT BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI) COMBINATION TYPE (CEC210.12). 20. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 30 MINUTES AND BE MICROWAVE / ULTRASONIC OR PASSIVE INFRA-RED TYPE. 21. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO SLEEPING ROOMS, IN EACH SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE, OR WITHIN 3 FEET OF DOORS TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY BACK-UP. DETECTORS TO BE INTERCONNECTED TO SOUND AT THE SAME TIME. 22. PROVIDE A MINIMUM OF 2 –20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED .(210-52(B)(2) 23. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHW ASHER, CLOTHES WASHER, DRYER, BUILT- IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT 24. ALL 15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPERRESISTANT RECEPTACLES ,ALL 15/20 AMPERE RECEPTACLES IN WET LOCATIONS SHALL HAVE IN-USE (BUBBLE) COVERS INSTALLED. ALL RECEPTACLES IN WET LOCATIONS SHALL ALSO BE LISTED W EATHER-RESISTANT TYPE GFCI. (CEC 406.9(B) (1)) 25. ALL LIGHTS ARE HIGH EFFICACY 26. ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1)) 27. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH EFFICACY. AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. 28. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE A ZERO CLEARANCE INSULATION COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND THE CEILING 29. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT CANDLE (11 LUX). 30. AT LEAST ONE LIGHTING SHALL BE INSTALLED IN THE ATTIC. 31. A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. 210-11(C)3) 32. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR AREA WITHIN 6FT FROM EDGE OF THE SINKS (CEC 210-8) 33. PROVIDE A MINIMUM OF 1 –20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. (210.11(C)(2) 34. IN THE KITCHEN AND DINING AREA, A RECEPTACLE SHALL BE PROVIDED FOR ISLAND COUNTERTOP SPACES WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES OR GREATER. (210-52(C)(2) 35. AT LEAST ONE LIGHT OUTLET, CONTROLLED BY A WALL SWITCH, SHALL BE INSTALLED IN EVERY HABITABLE ROOM, BATH ROOM, HALLWAY, GARAGE AND AT EACH OUT DOOR ENTRANCE. 36. GFCI AT ISLAND CANNOT HAVE MORE THAN 6 INCHES OVERHANG WHERE INSTALLED. 37. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL ON/OFF SWITCH MOTION SENSOR WITHOUT OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION SENSOR AND: A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES ASTRONOMICAL CLOCK C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT ALLOWS LUMINAIRES TO BE ALWAYS ON D. RATED FOR WET LOCATIONS 38. THE MINIMUM SIZE GROUND WIRE SHALL BE #8 CU OR #6 AL. 39. ALL SERVICES SHALL BE GROUNDED WITH A CONCRETE ENCASED ELECTRODE OR A GROUND ROD AND BONDED TO THE COLD WATER PIPE (N) DUAL-GANG ELECT. METER BOX (N) ADU ELECTRICAL SUB-PANEL 225 AMPS (PROVIDE MINIMUM 20 FEET UFER GROUND) MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL/ROOF) PHOTOCELL CONTROL / MOTION SENSOR 1 2 3 4 5 7 (N) HEAT PUMP UNIT ON 3'' THIK.CONCRETE PAD6 120-V WATERPROOF RECEPTACLE W/COVER8 EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF)9 10 EXHAUST FAN FOR BATHROOM SHALL BE MIN. 50 CFM AND CONTAIN HUMIDISTAT (EXHAUST THROUGH ROOF) (N) CONSUMER TANK WITH/ HEAT PUMP (N) 22X30 ATTIC ACCESS EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF) EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL IAQ FAN: ( MIN 46 CFM PER T-24 ) PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ BATTERY BACK UPCD 22X30 ATTIC ACCESS AIR HANDLERS HEATPUMP ON PAD 3" MIN. HEATPUMP WATER HEATER L.E.D. RECESSED LIGHT FIXTURE GF C I 110V DUPLEX OUTLET, ARC FAULT CIRCUIT INTERRUPTER (ENTIRE CIRCUIT) AF C I CEILING AIR DIFFUSER 110V DUPLEX OUTLET, GROUND FAULT CIRCUIT INTERRUPT (ENTIRE CIRCUIT) GARBAGE DISPOSAL SWITCH W/ MOTION SENSOR (VACANCY SENSOR) VS 2-WAY SWITCH 2D VANITY WALL LIGHT EXTERIOR WALL SCONCE LIGHT VS DIMMER SWITCH D ELECTRICAL PANEL/METER/INVERTER PER KEYNOTE MEDIA OUTLET P PHOTO CELL M J-BOX (CEILING FAN/LIGHT FIXTURE) DRYER EXHAUST W/P : WEATHER -RESISTANT W/R : WATER PROOF T THERMOSTAT WHOLE HOUSE FAN: 1186.5 CFM PER T-24 E ELECTRICAL VEHICLE CHARGING STATION LOCATION. 208/240-VOLT BRANCH CIRCUIT (40 AMP) 1 9F T C L ' G SD CDSD CDSD SD 30" 3 5 10 10 6 9 G/ A AFCI D AF C I P GFCI W/P,W/R 12 ' ' GF C I G/A G/A G/A GFCI 12'' GFCI 60'' FUTURE 240V -READY USE P AFCI AFCI 2D AF C I AF C I AFCI AF C I P P D D P P D 2D D VS VS VS 9FT CL'G 9FT CL'G 9FT CL'G 9FT CL'G 9FT CL'G 9FT CL'G VS GF C I GFCI 22 0 V G/ A , W / P 22 0 V G/ A , W / P D T T FUTURE 240V -READY USE 2D AFCI AFCI 2D 36'' CLR. FRONT OF PANEL D W/P.W/R GFCI FUTURE 240V -READY USE 2D 2D 2D GF C I E D GFCI GFCI GF C I GF C I AF C I 2D 7 7 77 AFCI 4 7 7 9FT CL'G D 12 ' ' GF C I 10 FT MIN. 12 ' - 1 1 " D ELECTRICAL VEHICLE CHARGING STATION LOCATION. 208/240-VOLT BRANCH CIRCUIT (40 AMP) 1 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2BATHS, LIVING , KITCHEN, DINING , GARAGE-1 CAR PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 28/11/2023 PLANNING CORRECTIONS LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/22/2024 1ST PLAN CHECK A.07 PROPOSED ADU ELECTRICAL PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 ELECTRICAL NOTESELECTRICAL PLAN KEYNOTESCEILING/ELECTRICAL PLAN LEGEND 1/4" = 1'-0"1PROPOSED ADU CEILING/LIGHTING & POWER PLAN LIGHTING REQUIREMENTS 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org NOTICE TO PROPERTY OWNER Dear Property Owner: APP-13 CBC 2016 An application for a building permit has been submitted in your nat,e listing yourself as the builder of the property improvements specified at q O l • M 1 f" t \ e.. St r U Y ½~ 2. 1 Set~ h. th,, I& , Yl: • We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your names as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEGMENT AND VERIFICATION OF INFORMATON DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. t,f 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner-Builder" build- ing permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my prop- erty. (( 2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. vf 3. I understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own . ..!f._ 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. (;p 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total vaite"ot my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. ~6. I understand if I am considered an "employer" under state and Federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment com- pensation of each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. J£_1. I understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless a// work is performed by licensed subcontrac- tors and the number of structures does not exceed four within any calendar years, or all of the work is performed under contract with a licensed general building Contractor. t4' 8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any finan-ci'a1or' personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workman- ship or materials. 901 E Myrtle St Unit# 2 - 1011181606/27/2024 ~9. I understand I may obtain more information regarding my obligations as an "employer'' from the Internal Revenue Ser- vice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Divi- sion of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800- 321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. t:f 10. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsi le for proposed construction activity at the following ad- dress: 0 E M r t,. V'\1' ~C:\V\fv. C-. (;f 11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. J£_ 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contactors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license. form notariza- tion. or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Signature of Property Owner -----~-4-~_P_h_~_VVI __________ Date: ___ O_k_f_z.._1_)_t.-1' __ '1-L1 __ Print name of Owner LO frN P 1-f {ti\/\ ____ ___;. ___ ~;._ ___________ _ AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project Scope of Construction Project (or Description of Work): _______________________ _ Project Location or Address:--------------------------------- Name of Authorized Agent:---------------------------------- Address of Authorized Agent: _______________________________ _ Phone Number of Authorized Agent:------------------------------- 1 declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Property Owner's Signature: ______________________ Date:. _________ _ Print Name of Owner: __________________________ _ Note: A copy of the owner's driver's 1/cense, form notarization, or other verification acceptable to the agency Is re- quired to be presented when the permit Is Issued to verify the property owner's signature. 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Structural Calculations Project No.: Amir Deihimi, 901 E Myrtle St Unit# 2 - 1011181606/27/2024 January, 18, 2023 Project: 23011 Location: 5463 Wadean PI Oakland, CA 94601, USA Client: N/A TABLE OF CONTENTS 901 E Myrtle St Unit# 2 - 1011181606/27/2024 ASCE 7 Hazards Report Address: 901 E Myrtle St Santa Ana, California 92701 Standard:ASCE/SEI 7-16 Latitude:33.741885 Risk Category:II Longitude:-117.856714 Soil Class:D - Default (see Section 11.4.3) Elevation:115.50170286928271 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Dec 26 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://asce7hazardtool.online/Tue Dec 26 2023 1 901 E Myrtle St Unit# 2 - 1011181606/27/2024 2 901 E Myrtle St Unit# 2 - 1011181606/27/2024 3 901 E Myrtle St Unit# 2 - 1011181606/27/2024 BUILDING INFORMATION A.General: Number of stories 1 Building risk category II Design Code 2022 CBC Load standard ASCE 7-16 Design Load Combination ASD B.Lateral Loads Data: WIND STANDARD ASCE 7-16(Directional Procedure) Exposure C Wind Speed V 95 Enclosure Enclosed Building Velocity pressure qz 0.00256KzKztKdKeV2 (26.10-1) Velocity pressure exposure coefficient Kz from (Table 26.10-1) Directionality Factor Kd 0.85 (Table 26.6-1) Topographic factor defined Kzt 1 (26.8.2) Gust Effect Factor G 0.85 (26.11) Pressures for MWFRS p qGCp – qi(GCpi)(27.3-1) External pressure coefficient Cp from (Fig. 27.3-1) Internal pressure coefficient (GCpi)0.18 (Table 26.13-1)} SEISMIC STANDARD ASCE 7-16(Equivalent Lateral Force Procedure) Seismic Design Category D (Table 11.6-1) Importance factor Ie 1 (Table 1.5-2) Soil Site Class D-Default (Table 20-3-1) Response Spectral Acc. (0.2 sec) Ss 1.284 Response Spectral Acc. (1.0 sec) S1 0.458 TL (sec)8 Fa 1.2 (Table 11.4-1) Fv 1.842 (Table 11.4-2) Max. Considered earthquake acc. SMS 1.541 (11.4-1) Max. Considered earthquake acc. SM1 .844 (11.4-2) Design spectral acc. At short period SDS 1.02 (11.4-3) Design spectral acc. at 1s period SD1 0.562 (11.4-4) Response modification coefficient R 6.5 (Table 12.2-1) System overstrength coefficient Ω2.5 (Table 12.2-1) Approximate fundamental period parameters Ct = 0.02 x = 0.75 (Table 12.8-2) Building Height (ft)15 Building period T=Ta (sec)0.152 (12.8-7) Base Shear Adjustment Factor 1 Minimum Cs 0.045 (12.8-5 & 12.8-6) Maximum Cs 0.568 (12.8-3 & 12.8-4) Seismic response coefficient Cs 0.158 (12.8-2) Adjusted Cs 0.158 For allowable stress design V = 0.7CsW 0.111W vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 .8 4 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Roof Loads (Load_Roof) Clay Tile 10 psf Framing 2.5 psf Sheathing (1/2" CDX)1.5 psf Ceiling 2.5 psf Insulation 1.5 psf Misc.2 psf Total De ad Load 20 psf Liv e Load 20 psf Total Load 40 psf Interior Wall (Wall_In) Insulation 1 psf Drywall 5 psf Studs 1 psf Misc.3 psf Total De ad Load 10 psf Exterior Wall (Wall_Ex) 7/8" Stucco 10 psf Insulation 1 psf Drywall 2.5 psf Studs 1 psf Misc.2.5 psf Total De ad Load 17 psf Ceiling Loads (Load_Ceiling) Framing 6 psf Total De ad Load 6 psf Liv e Load 10 psf Total Load 16 psf DESIGN LOADS vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 5 901 E Myrtle St Unit# 2 - 1011181606/27/2024 6 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SECTION D1 – DIRECTION X Bui l di ng Di m ensi on (ft):B = 41 L = 51.5 M ean Hei ght = 15 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 16.75 Depth = 9.75 Wi nd Hei ght = 15 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10.8' WIND LOAD: L/B =51.5/41=1.26, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.45, qh = 16.79 PSF Wal l (LW) P = GCplqh = 6.41 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 17.76 18.42 18.96 19.49 20.29 20.96 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Hi p W=16.75', L=9.75', Sl ope = 18.43° WW Hi p W=16.75', L=9.75', Sl ope = 18.43° LW -1.9 46.78 23.48 21.4 46.78 -1.9 21.4 23.48 D1X_ROOF = 82.86 = 0.6 x 138.09 PLF M AX T OT AL = 82.86 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 197 / 16.75 = 235.22 Wal l _Ex (DL)= 17 x 11.5 x (10.8/2) / 16.75 = 63.03 Cs*W = 0.1106 x (235.22 + 63.03)= 32.99 T OT AL SEISM IC LOAD 32.99 = 32.99 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D1X_ROOF 298.25 10.8 1 32.99 32.99 298.25 32.99 43.77 87.53 43.77 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D1X_ROOF 16.75 9 .75 3 7 .6 157.4 71.2 2 9 8 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e SECTION D1 – DIRECTION Y Bui l di ng Di m ensi on (ft):B = 51.5 L = 41 M ean Hei ght = 15 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 9.75 Depth = 16.75 Wi nd Hei ght = 11.5 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10.8' WIND LOAD: L/B =41/51.5=0.8, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.5, qh = 16.79 PSF Wal l (LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Gabl e W=9.75', L=16.75' WW Gabl e W=9.75', L=16.75' LW 5.88 7.11 10.11 2.88 7.11 5.88 2.88 10.11 D1Y_ROOF = 66.09 = 0.6 x 110.15 PLF M AX T OT AL = 66.09 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 197 / 9.75 = 404.10 Wal l _Ex (DL)= 17 x 10 x (10.8/2) / 9.75 = 94.15 Cs*W = 0.1106 x (404.10 + 94.15)= 55.11 T OT AL SEISM IC LOAD = 55.11 = 55.11 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D1Y_ROOF 498.26 10.8 1 55.11 55.11 498.26 55.11 73.12 146.23 73.12 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D1Y_ROOF 9.75 16.7 5 2 1 .3 51.9 19.2 46.9 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 7 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SECTION D2 – DIRECTION X Bui l di ng Di m ensi on (ft):B = 41 L = 51.5 M ean Hei ght = 15 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 24.5 Depth = 22.25 Wi nd Hei ght = 15 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10.8' WIND LOAD: L/B =51.5/41=1.26, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.45, qh = 16.79 PSF Wal l (LW) P = GCplqh = 6.41 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 17.76 18.42 18.96 19.49 20.29 20.96 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Hi p W=24.5', L=22.25', Sl ope = 18.43° WW Hi p W=24.5', L=22.25', Sl ope = 18.43° LW -1.9 46.78 23.48 21.4 46.78 -1.9 21.4 23.48 D2X_ROOF = 82.86 = 0.6 x 138.09 PLF M AX T OT AL = 82.86 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 641 / 24.5 = 523.27 Wal l _Ex (DL)= 17 x 35 x (10.8/2) / 24.5 = 131.14 Wal l _In (DL)= 10 x 25 x (10.8/2) / 24.5 = 55.10 Cs*W = 0.1106 x (523.27 + 131.14 + 55.10)= 78.47 T OT AL SEISM IC LOAD 78.47 = 78.47 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D2X_ROOF 709.51 10.8 1 78.47 78.47 709.51 78.47 104.12 208.23 104.12 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D2X_ROOF 24.5 22.2 5 5 7 .3 351.1 45.6 279.4 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e SECTION D2 – DIRECTION Y Bui l di ng Di m ensi on (ft):B = 51.5 L = 41 M ean Hei ght = 15 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 22.25 Depth = 24.5 Wi nd Hei ght = 11.5 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10.8' WIND LOAD: L/B =41/51.5=0.8, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.5, qh = 16.79 PSF Wal l (LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Gabl e W=22.25', L=24.5' WW Gabl e W=22.25', L=24.5' LW 5.88 7.11 10.11 2.88 7.11 5.88 2.88 10.11 D2Y_ROOF = 66.09 = 0.6 x 110.15 PLF M AX T OT AL = 66.09 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 641 / 22.25 = 576.18 Wal l _Ex (DL)= 17 x 34 x (10.8/2) / 22.25 = 140.28 Cs*W = 0.1106 x (576.18 + 140.28)= 79.24 T OT AL SEISM IC LOAD = 79.24 = 79.24 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D2Y_ROOF 716.46 10.8 1 79.24 79.24 716.46 79.24 105.14 210.27 105.14 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D2Y_ROOF 22.25 2 4 .5 4 7 .7 265.6 30 166.9 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 8 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SECTION D3 – DIRECTION X Bui l di ng Di m ensi on (ft):B = 41 L = 51.5 M ean Hei ght = 15 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 15 Depth = 29.5 Wi nd Hei ght = 11.5 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10.8' WIND LOAD: L/B =51.5/41=1.26, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.45, qh = 16.79 PSF Wal l (LW) P = GCplqh = 6.41 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 17.76 18.42 18.96 19.49 20.29 20.96 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Gabl e W=15', L=29.5' WW Gabl e W=15', L=29.5' LW 5.88 6.6 10.11 2.37 6.6 5.88 2.37 10.11 D3X_ROOF = 63.42 = 0.6 x 105.69 PLF M AX T OT AL = 63.42 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 500 / 15 = 666.67 Wal l _Ex (DL)= 17 x 15 x (10.8/2) / 15 = 91.80 Wal l _In (DL)= 10 x 25 x (10.8/2) / 15 = 90.00 Cs*W = 0.1106 x (666.67 + 91.80 + 90.00)= 93.84 T OT AL SEISM IC LOAD 93.84 = 93.84 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D3X_ROOF 848.47 10.8 1 93.84 93.84 848.47 93.84 124.51 249.01 124.51 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D3X_ROOF 1 5 2 9 .5 3 1 .7 118.7 16.1 60.5 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e SECTION D3 – DIRECTION Y Bui l di ng Di m ensi on (ft):B = 51.5 L = 41 M ean Hei ght = 15 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 29.5 Depth = 15 Wi nd Hei ght = 15 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10.8' WIND LOAD: L/B =41/51.5=0.8, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.5, qh = 16.79 PSF Wal l (LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Hi p W=29.5', L=15', Sl ope = 18.43° WW Hi p W=29.5', L=15', Sl ope = 18.43° LW -1.9 46.78 23.48 21.4 46.78 -1.9 21.4 23.48 D3Y_ROOF = 85.23 = 0.6 x 142.04 PLF M AX T OT AL = 85.23 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 500 / 29.5 = 338.98 Wal l _Ex (DL)= 17 x 57 x (10.8/2) / 29.5 = 177.38 Wal l _In (DL)= 10 x 14 x (10.8/2) / 29.5 = 25.63 Cs*W = 0.1106 x (338.98 + 177.38 + 25.63)= 59.94 T OT AL SEISM IC LOAD = 59.94 = 59.94 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D3Y_ROOF 541.99 10.8 1 59.94 59.94 541.99 59.94 79.53 159.07 79.53 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D3Y_ROOF 29.5 15 7 8 .2 576.8 83.8 618.1 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 9 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SHEARWALL AND HARDWARE SCHEDULES (De sign Code : 2022 CBC) A. SHEARWALL SCHEDULE Pane l Type She athing Edge Nail Fie ld Nail Se ismic Allowable (plf) Wind Allowable (plf)Sole Plate Nailing She ar Clip M udsill Anchors Ga (k/in)2x Mudsill 3x Mudsill SW1 3/8" Sheathing 8d @ 6 8d @ 12 260 364 16d Nails @ 6 A35 @ 24 5/8 x 10 @48 -13 SW2 3/8" Sheathing 8d @ 4 8d @ 12 380 532 16d Nails @ 4 A35 @ 16 5/8 x 10 @ 42 -19 SW3 3/8" Sheathing 8d @ 3 8d @ 12 490 686 16d Nails @ 3 A35 @ 8 5/8 x 10 @ 36 -25 SW4 3/8" Sheathing 8d @ 2 8d @ 12 640 896 16d Nails @ 2 A35 @ 8 5/8 x 10 @ 24 -39 SW5 15/32" Structural I 10d @ 2 10d @ 12 800 1120 (2) Rows Stagg, 16d Nails @ 3 A35 @ 6 5/8 x 10 @18 -51 SW3D 3/8" Sheathing 8d @ 3 8d @ 12 980 1372 SDS1/4x6 @ 4 (Both Sides)A35 @ 8 -5/8 x 12 @ 22 50 SW4D 3/8" Sheathing 8d @ 2 8d @ 12 1280 1792 SDS1/4x6 @ 3 (Both Sides)A35 @ 8 -5/8 x 12 @ 16 78 SW5D 15/32" Structural I 10d @ 2 10d @ 12 1600 2241 SDS1/4x6 @ 2 (Both Sides)A35 @ 6 -5/8 x 12 @8 102 B. HOLDOWN SCHEDULE Holdown M in. Post Conne ctors Anchor Bolt Allowable (lbs)Displace me nt all da (in)Re marks HDU2 4X4 6-SDS1/4x2 1/2 5/8"3075 0.088 HD1 HDU4 4X4 10-SDS1/4x2 1/2 5/8"4565 0.114 HD2 HDU5 4X4 14-SDS1/4x2 1/2 5/8"5645 0.115 HD3 HDU8 4X6 20-SDS1/4x2 1/2 7/8"7870 0.113 HD4 HDU11 4X8 30-SDS1/4x2 1/2 1"11175 0.137 HD5 HDU14 4X8 36-SDS1/4x2 1/2 1"14375 0.177 HD6 C. HOLDOWN STRAP SCHEDULE Strap M in. Post Conne ctors Allowable (lbs)Displace me nt all da (in)Re marks CS16 2X4 22-10d 1705 0.026 A (2)CS16 2-2X4 22-10d 3410 0.026 B (2)CS14 2-2X4 30-10d 4980 0.031 C CMST14 4X4 80-16d 6490 0.052 D (3)CS14 3-2X4 30-10d 7470 0.031 C* CMST12 4X6 104-16d 9200 0.069 E (2)CMST14 4X8 80-16d 12980 0.052 F (2)CMST12 6X8 104-16d 18400 0.069 G D. PLATE SPLICE STRAP SCHEDULE Straps Alt. Nails pe r top plate splice Allowable Te nsion Loads Re marksTypeGaFasteners Simpson ST22 16 18-16d 10-16d sinker 1420 A Simpson ST6224 16 28-16d 16-16d sinker 2540 B Simpson ST6236 14 40-16d 22-16d sinker 3845 C Simpson MST37 12 42-16d 24-16d sinker 5080 D Simpson MSTC52 16 62-16d 32-16d sinker 5649 E Simpson MST60 10 68-16d 36-16d sinker 6730 F Simpson CMST12x72"12 74-16d 42-16d sinker 9215 G vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 10 901 E Myrtle St Unit# 2 - 1011181606/27/2024 OVERTURNING LOAD COMBINATIONS (De sign Code : 2022 CBC) ULIFT DOWN 1. 0.6D - 0.6W 1. D + 0.6W 2. (0.6 - 0.14Sds)D - 0.7ρE 2. D + 0.75(L + Lr + 0.6W) 3. D + 0.75(L + S + 0.6W) 4. (1+0.105Sds)D + 0.75(L + S + 0.7ρE) 5. (1+0.14Sds)D + 0.7ρE vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 11 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE A 1st Floor Passe d Exterior Wall Drection X Location:(1.14, -15.85) Loads SECTION D3X_ROOF: W=468 LB, E=692 LB (14.75ft) SECTION D2X_ROOF: W=1005 LB, E=951 LB (24.25ft) Wall Self-Weight Seismic = 635 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 54.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 184 346 380 532 380 SW2 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1910 2766 680 226 0 0 0 1910 2766 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 3285 3854 HDU4/4X4 0.72/0.50 3285 3854 HDU4/4X4 0.72/0.50 1.694 2.400 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 12 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE B 1st Floor Passe d Exterior Wall Drection X Location:(1.14, -1.12) Loads SECTION D3X_ROOF: W=476 LB, E=704 LB (15ft) SECTION D2X_ROOF: W=1025 LB, E=971 LB (24.75ft) Wall Self-Weight Seismic = 433 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 51.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 188 326 380 532 380 SW2 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1947 2605 680 226 0 0 0 1947 2605 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 3076 3645 HDU4/4X4 0.67/0.48 3076 3645 HDU4/4X4 0.67/0.48 1.593 2.400 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 13 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE C 1st Floor Passe d Exterior Wall Drection X Location:(30.49, 5.96) Loads SECTION D1X_ROOF: W=787 LB, E=313 LB (19ft) SECTION D2X_ROOF: W=404 LB, E=383 LB (9.75ft) Wall Self-Weight Seismic = 181 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 22.00 Total panel Length (ft): 4.68 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 2.43 7.40 3.05 255 232 380 462 330 SW2 (2) B 2.25 7.40 3.29 255 232 380 446 319 SW2 (2) Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 207 226 0 0 0 2893 2029 207 226 0 0 0 2893 2029 B 191 226 0 0 0 2925 2051 191 226 0 0 0 2925 2051 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 2.43 10.00 2769 3119 HDU2/4X4 0.90/0.41 2769 3119 HDU2/4X4 0.90/0.41 2.003 2.400 B 2.25 10.00 2810 3151 HDU2/4X4 0.91/0.41 2810 3151 HDU2/4X4 0.91/0.41 2.141 2.400 (2) Tension on strap = 2215 < 3300x2 = 6000 Use (2)ST6236 Each Post. See detail on plan for more information. vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 14 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE D 1st Floor Passe d Exterior Wall Drection X Location:(30.49, 19.72) Loads SECTION D1X_ROOF: W=694 LB, E=276 LB (16.75ft) Wall Self-Weight Seismic = 75 LB USE STANDARD SIM PSON HIGH STRONG WALL WOOD SHEARWALL Total Length (ft): 10.00 Total panel Length (ft): 1.00 ρ = 1.3 No. of Pane l M ode l Wind She ar (lbs)Se ismic She ar (lbs)De fle ction (in) Dist. She ar Allow. She ar Dist. She ar Allow. She ar Wind Se ismic Allow. 1 WSWH12x10 694 900 434 700 0.517 0.31 2.4 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 15 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE E 1st Floor Passe d Exterior Wall Drection X Location:(0.00, 0.00) Loads SECTION D1X_ROOF: W=217 LB, E=87 LB (5.25ft) Wall Self-Weight Seismic = 13 LB She arwall De sign USE TYPE: SW1 Total Length (ft): 10.00 Total panel Length (ft): 0.00 ρ = 1.0 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 16 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Seismic Calcs Date: 2/29/2024 LINE E : Timber Frames Lateral Load is imported from Wood Frame Analysis (R = 6.5, p = 1.3, ASD Method) ww =0.217 kip Ew =0.099 kip Lateral Load is increased ( Timber Frames ) (R = 1.5, p = 1.3, LRFD Method) W w 0.217 0.6 0.6 Ew x 6.5 0.099 x 6.5 1.5 x 0.7 1.5 x 0.7 Total load on Each Cant. Column 0.36 2 0.47 2 W= E = W= E = = = = = 0.18 kip 0.24 kip = = 0.36 0.47 kip kip 17 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Wood Column LIC# : KW-06014368, Build:20.23.2.14 .(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE E Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: .Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 6x6Analysis Method : 9Overall Column Height ft Load Resistance Factor Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top Free, Bottom Fixed Wood Species Douglas Fir-Larch Wood Grade No.1 Fb +1,200.0 1,200.0 psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf.Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi No Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 9 ft, K = 2.1 Unbraced Length for buckling ABOUT Y-Y Axis = 9 ft, K = 2.1 Brace condition for deflection (buckling) along columns : .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 59.006 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 9.0 ft, D = 0.1720, Lr = 0.1390 k BENDING LOADS . . . Lat. Point Load at 9.0 ft creating Mx-x, W = 0.180, E = 0.240 k .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.3708 Location of max.above base 0.0 ft Applied Axial 0.3247 k Applied Mx -2.160 k-ft Load Combination +1.405D+E Load Combination +0.6946D-E Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 11.901 psi 367.20Allowable Shear psi 0.02161 : 1 Bending Compression Tension LRFD - Format Conversion factor 2.541 2.400 2.700 LRFD - Resistance factor 0.850 0.900 0.800Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0 k Bottom along Y-Y 0.240 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.8218 in at 9.0 ft above base for load combination :E Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 402.161 psi Other Factors used to calculate allowable stresses . . . for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCLambdaLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +1.20D+0.50Lr 0.800 PASS PASS0.0 0.0 0.0 ft0.230 ft0.02888 +1.20D 0.800 PASS PASS0.0 0.0 0.0 ft0.230 ft0.02309 +1.20D+1.60Lr 0.800 PASS PASS0.0 0.0 0.0 ft0.230 ft0.04161 +1.20D+1.60Lr+0.50W 0.800 PASS PASS0.0 0.01013 0.0 ft0.230 ft0.1777 +1.20D+1.60Lr-0.50W 0.800 PASS PASS0.0 0.01013 0.0 ft0.230 ft0.1777 +1.20D+0.50W 0.800 PASS PASS0.0 0.01013 0.0 ft0.230 ft0.1733 +1.20D-0.50W 0.800 PASS PASS0.0 0.01013 0.0 ft0.230 ft0.1733 +1.20D+0.50Lr+W 1.000 PASS PASS0.0 0.01621 0.0 ft0.186 ft0.2789 +1.20D+0.50Lr-W 1.000 PASS PASS0.0 0.01621 0.0 ft0.186 ft0.2789 18 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Wood Column LIC# : KW-06014368, Build:20.23.2.14 .(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE E Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCLambdaLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +1.20D+W 1.000 PASS PASS0.0 0.01621 0.0 ft0.186 ft0.2770 +1.20D-W 1.000 PASS PASS0.0 0.01621 0.0 ft0.186 ft0.2770 +0.90D+W 1.000 PASS PASS0.0 0.01621 0.0 ft0.186 ft0.2753 +0.90D-W 1.000 PASS PASS0.0 0.01621 0.0 ft0.186 ft0.2753 +1.405D+E 1.000 PASS PASS0.0 0.02161 0.0 ft0.186 ft0.3708 +1.405D-E 1.000 PASS PASS0.0 0.02161 0.0 ft0.186 ft0.3708 +0.6946D+E 1.000 PASS PASS0.0 0.02161 0.0 ft0.186 ft0.3654 +0.6946D-E 1.000 PASS PASS0.0 0.02161 0.0 ft0.186 ft0.3654 . k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.231 +D+Lr 0.370 +D+0.750Lr 0.335 +D+0.60W 0.2310.108 0.972 +D-0.60W 0.231-0.108 -0.972 +D+0.750Lr+0.450W 0.3350.081 0.729 +D+0.750Lr-0.450W 0.335-0.081 -0.729 +D+0.450W 0.2310.081 0.729 +D-0.450W 0.231-0.081 -0.729 +0.60D+0.60W 0.1390.108 0.972 +0.60D-0.60W 0.139-0.108 -0.972 +D+0.70E 0.2310.168 1.512 +D-0.70E 0.231-0.168 -1.512 +D+0.5250E 0.2310.126 1.134 +D-0.5250E 0.231-0.126 -1.134 +0.60D+0.70E 0.1390.168 1.512 +0.60D-0.70E 0.139-0.168 -1.512 Lr Only 0.139 W Only 0.180 1.620 -W -0.180 -1.620 E Only 0.240 2.160 E Only * -1.0 -0.240 -2.160 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin0.000 +D+Lr 0.0000 0.000 0.000ftftinin0.000 +D+0.750Lr 0.0000 0.000 0.000ftftinin0.000 +D+0.60W 0.0000 0.370 9.000ftftinin0.000 +D-0.60W 0.0000 -0.370 9.000ftftinin0.000 +D+0.750Lr+0.450W 0.0000 0.277 9.000ftftinin0.000 +D+0.750Lr-0.450W 0.0000 -0.277 9.000ftftinin0.000 +D+0.450W 0.0000 0.277 9.000ftftinin0.000 +D-0.450W 0.0000 -0.277 9.000ftftinin0.000 +0.60D+0.60W 0.0000 0.370 9.000ftftinin0.000 +0.60D-0.60W 0.0000 -0.370 9.000ftftinin0.000 +D+0.70E 0.0000 0.575 9.000ftftinin0.000 +D-0.70E 0.0000 -0.575 9.000ftftinin0.000 +D+0.5250E 0.0000 0.431 9.000ftftinin0.000 +D-0.5250E 0.0000 -0.431 9.000ftftinin0.000 +0.60D+0.70E 0.0000 0.575 9.000ftftinin0.000 +0.60D-0.70E 0.0000 -0.575 9.000ftftinin0.000 Lr Only 0.0000 0.000 0.000ftftinin0.000 W Only 0.0000 0.616 9.000ftftinin0.000 -W 0.0000 -0.616 9.000ftftinin0.000 E Only 0.0000 0.822 9.000ftftinin0.000 E Only * -1.0 0.0000 -0.814 8.940ftftinin0.000 . 19 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Wood Column LIC# : KW-06014368, Build:20.23.2.14 .(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE E Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 20 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE 1 1st Floor Passe d Exterior Wall Drection Y Location:(1.14, -15.85) Loads SECTION D3Y_ROOF: W=1246 LB, E=877 LB (29.25ft) Wall Self-Weight Seismic = 168 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 15.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 156 163 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1617 1305 680 226 0 0 0 1617 1305 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 1386 1955 HDU2/4X4 0.45/0.26 1386 1955 HDU2/4X4 0.45/0.26 1.028 2.400 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 21 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE 2 1st Floor Passe d Exterior Wall Drection Y Location:(30.49, -1.42) Loads SECTION D1Y_ROOF: W=322 LB, E=269 LB (9.75ft) SECTION D2Y_ROOF: W=727 LB, E=872 LB (22ft) SECTION D3Y_ROOF: W=1268 LB, E=892 LB (29.75ft) Wall Self-Weight Seismic = 259 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 26.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 290 363 380 532 380 SW2 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 3006 2895 680 226 0 0 0 3006 2895 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 3453 4022 HDU4/4X4 0.76/0.53 3453 4022 HDU4/4X4 0.76/0.53 1.776 2.400 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 22 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE 3 1st Floor Passe d Exterior Wall Drection Y Location:(40.10, 8.33) Loads SECTION D1Y_ROOF: W=330 LB, E=276 LB (10ft) Wall Self-Weight Seismic = 139 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 11.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 41 62 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 429 496 680 226 0 0 0 429 496 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 335 904 HDU2/4X4 0.11/0.12 335 904 HDU2/4X4 0.11/0.12 0.353 2.400 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 23 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SW_LINE 4 1st Floor Passe d Exterior Wall Drection Y Location:(52.48, -15.85) Loads SECTION D2Y_ROOF: W=727 LB, E=872 LB (22ft) Wall Self-Weight Seismic = 296 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 16.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 91 179 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 943 1426 680 226 0 0 0 943 1426 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 1543 2112 HDU2/4X4 0.50/0.28 1543 2112 HDU2/4X4 0.50/0.28 1.129 2.400 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 24 901 E Myrtle St Unit# 2 - 1011181606/27/2024 LOAD COMBINATIONS (Load Standard: ASCE 7-16) id Load case De ad Sds*De ad Liv e Roof Liv e Snow Wind Se ismic Dire ction Load Dur ation Factor CD 1 D 1 0.9 2 D + L 1 1 1 3 D + Lr 1 1 1.25 4 D + S 1 1 1.15 5 D + 0.75L + 0.75Lr 1 0.75 0.75 1.25 6 D + 0.75L + 0.75S 1 0.75 0.75 1.15 7 D + 0.6W (N)1 0.6 N_S 1.6 8 D + 0.6W (S)1 0.6 S_N 1.6 9 D + 0.6W (E)1 0.6 E_W 1.6 10 D + 0.6W (W)1 0.6 W_E 1.6 11 D + 0.75(0.6W) (N) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 N_S 1.6 12 D + 0.75(0.6W) (S) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 S_N 1.6 13 D + 0.75(0.6W) (E) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 E_W 1.6 14 D + 0.75(0.6W) (W) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 W_E 1.6 15 D + 0.75(0.6W) (N) + 0.75L + 0.75S 1 0.75 0.75 0.45 N_S 1.6 16 D + 0.75(0.6W) (S) + 0.75L + 0.75S 1 0.75 0.75 0.45 S_N 1.6 17 D + 0.75(0.6W) (E) + 0.75L + 0.75S 1 0.75 0.75 0.45 E_W 1.6 18 D + 0.75(0.6W) (W) + 0.75L + 0.75S 1 0.75 0.75 0.45 W_E 1.6 19 0.6D + 0.6W (N)0.6 0.6 N_S 1.6 20 0.6D + 0.6W (S)0.6 0.6 S_N 1.6 21 0.6D + 0.6W (E)0.6 0.6 E_W 1.6 22 0.6D + 0.6W (W)0.6 0.6 W_E 1.6 23 (1.0 + 0.14Sds)D + 0.7ΩE (N)1 0.14 0.7 N_S 1.6 24 (1.0 + 0.14Sds)D + 0.7ΩE (S)1 0.14 0.7 S_N 1.6 25 (1.0 + 0.14Sds)D + 0.7ΩE (E)1 0.14 0.7 E_W 1.6 26 (1.0 + 0.14Sds)D + 0.7ΩE (W)1 0.14 0.7 W_E 1.6 27 (1.0 + 0.105Sds)D + 0.525ΩE (N) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 N_S 1.6 28 (1.0 + 0.105Sds)D + 0.525ΩE (S) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 S_N 1.6 29 (1.0 + 0.105Sds)D + 0.525ΩE (E) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 E_W 1.6 30 (1.0 + 0.105Sds)D + 0.525ΩE (W) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 W_E 1.6 31 (0.6 - 0.14Sds)D + 0.7ΩE (N)0.6 -0.14 0.7 N_S 1.6 32 (0.6 - 0.14Sds)D + 0.7ΩE (S)0.6 -0.14 0.7 S_N 1.6 33 (0.6 - 0.14Sds)D + 0.7ΩE (E)0.6 -0.14 0.7 E_W 1.6 34 (0.6 - 0.14Sds)D + 0.7ΩE (W)0.6 -0.14 0.7 W_E 1.6 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 25 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Be am ID: RR1 Section type:Douglas Fir-Larch No.2 Section name:2x8 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 53.4PLF =2.67 x (20+20)/2 @ 0' to 10.75' SELF WEIGHT 2.55PLF From 0' to 10.75' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.2 Cfu = 1 Ci = 1 Cr = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 157 0 144 0 0 0 0 0 301/0 2 157 0 144 0 0 0 0 0 301/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)808 5.38 1478 55 1.25 Shear (lbs)265 0 1631 16 1.25 Live Deflection 0.105 5.38 0.358 29 - Total Deflection 0.221 5.38 0.538 41 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: CJ1 Section type:Douglas Fir-Larch No.2 Section name:2x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Ceiling 21.36PLF =2.67 x (6+10)/2 @ 0' to 14' SELF WEIGHT 1.93PLF From 0' to 14' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 70 0 93 0 0 0 0 0 163/0 2 70 0 93 0 0 0 0 0 163/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)571 7 922 62 1.25 Shear (lbs)152 0 1238 12 1.25 Live Deflection 0.347 7 0.467 74 - Total Deflection 0.605 7 0.7 86 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 26 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Be am ID: 1 Section type:Douglas Fir-Larch No.2 Section name:4x8 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 8.42 Ignore shear within (d): True Repetitive member : False Applie d Loads: Wall_Ex 76.5PLF =4.5 x 17 @ 0' to 8.42' Load_Roof 60PLF =3 x (20+20)/2 @ 0' to 8.42' SELF WEIGHT 5.95PLF From 0' to 8.42' Factors: Ct = 1 Cm = 1 CL = 0.99 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 473 0 126 0 0 0 0 0 600/0 2 473 0 126 0 0 0 0 0 600/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)997 4.21 2664 37 0.9 Shear (lbs)402 0 2741 15 0.9 Live Deflection 0.019 4.21 0.281 7 - Total Deflection 0.091 4.21 0.421 22 - Passe d Max Moment: D Max Shear: D Max Deflection: D + Lr Be am ID: 2 Section type:Douglas Fir-Larch No.1 Section name:6x6 Fb(+)/Fb(-) (psi): 1350/1350 Fv (psi): 170 E (psi): 1600000 Lu (ft): 5.08 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 235PLF =11.75 x (20+20)/2 @ 0' to 5.08' SELF WEIGHT 7.09PLF From 0' to 5.08' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 316 0 298 0 0 0 0 0 615/0 2 316 0 298 0 0 0 0 0 615/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)781 2.54 3889 20 1.25 Shear (lbs)497 5.08 4285 12 1.25 Live Deflection 0.014 2.54 0.169 8 - Total Deflection 0.030 2.54 0.254 12 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 27 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Be am ID: 3 Section type:Douglas Fir-Larch No.1 Section name:6x6 Fb(+)/Fb(-) (psi): 1350/1350 Fv (psi): 170 E (psi): 1600000 Lu (ft): 9.28 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 60PLF =3 x (20+20)/2 @ 0' to 9.28' SELF WEIGHT 7.09PLF From 0' to 9.28' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 172 0 139 0 0 0 0 0 311/0 2 172 0 139 0 0 0 0 0 311/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)722 4.64 3880 19 1.25 Shear (lbs)281 0 4285 7 1.25 Live Deflection 0.041 4.64 0.309 13 - Total Deflection 0.092 4.64 0.464 20 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: 4 Section type:Ve rsa Lam 3100 Section name:3 1/2x11 7/8 Fb(+)/Fb(-) (psi): 3100/3100 Fv (psi): 285 E (psi): 2000000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 425PLF =21.25 x (20+20)/2 @ 0' to 14.4' Load_Roof 26.6PLF =1.33 x (20+20)/2 @ 0' to 14.4' SELF WEIGHT 9.74PLF From 0' to 14.4' Factors: Ct = 1 Cm = 1 CL = 1.00 Cr = 1 Cv = 1.00 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 1696 0 1626 0 0 0 0 0 3322/0 2 1696 0 1626 0 0 0 0 0 3322/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)11958 7.2 26563 45 1.25 Shear (lbs)3322 14.4 9871 34 1.25 Live Deflection 0.224 7.2 0.48 47 - Total Deflection 0.457 7.2 0.72 63 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 28 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Project: COLAR TIE Location: CT1 page of StruCalc 9.0 StruCalc Version 10.0.1.5 4/5/2022 12:54:40 AM Collar Tie [2015 International Building Code(2015 NDS)] 1.5 IN x 7.25 IN x 12.0 FT (11 + 1) @ 16 O.C. #2 - Douglas-Fir-Larch - Dry Use 1.5 x 5.5 Solid Sawn Lumber with minimum Ft = 575 Section Adequate By: 72.8% Controlling Factor: Deflection DEFLECTIONS Live Load Dead Load Total Load Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 0.14 0.14 0.28 IN L/1011 in IN L/505 Center -0.04 -0.04 -0.08 IN 2L/622 in IN 2L/312 Right RAFTER REACTIONS Lower Live Load @ A & B Lower Dead Load @ A & B Lower Total Load @ A & B Collar Tie Tension LOADS 253 253 506 plf plf plf REACTIONS 337 337 674 924 lb lb lb lb RAFTER SUPPORT DATA Bearing Length B 0.72 in RAFTER DATA Span Length Unbraced Length-Bottom Rafter Pitch Collar Tie Location Roof Duration Factor Peak Notch Depth Base Notch Depth 11 11.6 4 4.07 1.15 0.00 0.00 ft ft Interior :12 ft 1 1.05 ft ft Eave MATERIAL PROPERTIES Bending Stress: Shear Stress: Modulus of Elasticity: Comp. ┴ to Grain: Controlling Moment: 5.502 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: At a distance d from right support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2, 3 Comparisons with required sections: Section Modulus: Area (Shear): Moment of Inertia (deflection): Moment: Shear: Fb = Cd=1.15 CF=1.20 Cr=1.15 Fv = Cd=1.15 E = Fc - ┴ = 843 ft-lb -266 lb 900 180 1600 625 psi psi ksi psi Base Values Fb' = Fv' = E' = Fc - ┴' = 1428 207 1600 625 psi psi ksi psi Adjusted 7.08 1.93 27.56 843 -266 in3 in2 in4 ft-lb lb Req'd 13.14 10.88 47.63 1564 1501 in3 in2 in4 ft-lb lb Provided RAFTER LOADING Uniform Floor Loading Roof Live Load: Roof Dead Load: Slope Adjusted Spans And Loads Interior Span: Eave Span: Rafter Live Load: Eave Live Load: Rafter Dead Load: Rafter Total Load: Eave Total Load: LL = DL = L-adj = L-Eave-adj = wL-adj = wL-Eave-adj = wD-adj = wT-adj = wT-Eave-adj = 20 20 11.6 1.05 24 24 25 49 49 psf psf ft ft plf plf plf plf plf LOADING DIAGRAM 1 ft 11 ft 4.07 ft 22 ft 0.23 ft COLLAR TIE DESIGN 1.5 x 5.5 Solid Sawn Lumber with minimum Ft = 575 Tension Parallel to Grain Collar Tie Location Collar Tie Tension Collar Tie Capacity Nailing Required @ Both Ends 16d Common 16d Sinker 16d Box Ft = Cd=1.15 Cf=0.00 575 4.07 924 8183 6 Nails 7 Nails 8 Nails psi ft lb lb Base Values Ft' = 992 psi Adjusted 29 901 E Myrtle St Unit# 2 - 1011181606/27/2024 Weight of Footing Load_Roof Wall_Ex Footing/Pad ID: CF1 Continuous Footing Soil Bearing: SB = 2400 PSF Post with parallel to footing: Bp = 3.5 in Loads: 225.00 PLF = 150 x 1.00' x 1.50' 490PLF =24.5 x (20+20)/2 153PLF =9 x 17 Design Footing: Total Weight: Wtotal = 868 PLF Footing Width Required: Bf = Wtotal / SB = 868/2400 x 12 = 4.34 in USE 12" WIDE X 18" DEEP Continuous Footing with #4 Cont. @ T & B (U.N.O) vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 GENERAL INFORMATION 01 Project Name 901 E Myrtle St - Unit 2 ADU 02 Run Title Title 24 Analysis 03 Project Location 901 E Myrtle St 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92701 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)791 19 Glazing Percentage (%)9.55% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 38.2 37.5 27.9 Proposed Design 37.2 37.5 27.9 1 0 0 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.15 kWdc •PV System resized to 2.15 kWdc (a factor of 2.148) to achieve 'Standard Design PV' PV scaling 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.34 1.6 0.46 3.35 -0.12 -1.75 Space Cooling 1.24 26.8 1.2 29.29 0.04 -2.49 IAQ Ventilation 0.45 4.71 0.45 4.71 0 0 Water Heating 2.21 23.33 1.76 19.05 0.45 4.28 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 4.24 56.44 3.87 56.4 0.37 0.04 Photovoltaics -2.98 -89.38 -2.98 -89.16 Battery 0 0 Flexibility Indoor Lighting 1.04 9.74 1.04 9.74 Appl. & Cooking 6.97 46.95 6.95 46.82 Plug Loads 5.74 58.48 5.74 58.48 Outdoor Lighting 0.21 1.81 0.21 1.81 TOTAL COMPLIANCE 15.22 84.04 14.83 84.09 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 23.34 22.64 0.7 3 Net EUI2 8.2 7.5 0.7 8.54 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.15 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Whole house fan •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Fan Efficacy Watts/CFM •Verified HSPF2 •Verified heat pump rated heating capacity •Duct leakage testing BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 901 E Myrtle St - Unit 2 ADU 791 1 2 1 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Area Conditioned HVAC System1 791 10 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) North Wall Living Area R-15 Wall1 0 Left 310 53.33 90 South Wall Living Area R-15 Wall1 180 Right 310 17.25 90 West Wall Living Area R-15 Wall1 270 Front 285 25 90 East Wall Living Area R-15 Wall1 90 Back 91 0 90 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) GRG > ADU __Garage__>>Living Area R-15 Wall n/a n/a 192 0 n/a Roof Living Area R-38 + R-19 Roof Attic n/a n/a 791 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 305 n/a n/a North Wall 2 __Garage__R-0 Wall 0 Left 100 64 90 South Wall 2 __Garage__R-0 Wall 180 Right 100 0 90 East Wall 2 __Garage__R-0 Wall 90 Back 192 0 90 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Attic Living Area Attic RoofLiving Area Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading D-5068 Window North Wall Left 0 1 33.33 0.3 NFRC 0.23 NFRC Bug Screen WA-5040 Window North Wall Left 0 1 20 0.3 NFRC 0.23 NFRC Bug Screen WB-2620 Window South Wall Right 180 1 5 0.3 NFRC 0.23 NFRC Bug Screen WC-3636 Window South Wall Right 180 1 12.25 0.3 NFRC 0.23 NFRC Bug Screen WB-2620 2 Window West Wall Front 270 1 5 0.3 NFRC 0.23 NFRC Bug Screen 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1-3068 West Wall 20 0.5 D7-8080 North Wall 2 64 1 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Living Area 791 150 none 0 80%No Slab-on-Grade 2 __Garage__305 50 none 0 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall1 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Other Side Finish: Gypsum Board 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofLiving Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-38 + R-19 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem PROPH40 T2 RH37530 (40 gal, JA13) TankZone __Garage____Garage__ WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF2 9.5 36000 24000 EER2SEER2 18 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 450 Required Required No Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 46 0.35 Exhaust No n/a / n/a No Yes COOLING VENTILATION 01 02 03 04 05 06 07 08 09 Name Airflow Rate (CFM/ft2)Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans CFVCS Type Exhausts to HERS Verification Whole House Fan 1.5 1186.5 0.14 166.11 1 Not a CFVCS Attic 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2023-12-19T15:57:49+07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-19   00:58:59 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   901 E Myrtle St Unit# 2 - 1011181606/27/2024 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 PLB-02 CPC 2022 1" MINIMUM FROM COMBUSTIBLES Applicable Codes: 1.2022 California Plumbing Code (CPC) 2.2022 California Mechanical Code (CMC) 3.2022 California Energy Code (Title24, Part 6) 4.2022 California Building Code (CBC) 5.Santa Ana Municipal Code 6.City of Santa Ana Citywide Design Guidelines APPROVED RIGID METALBRACKET INTO THE BLDG. THE PLANNING DIVISION FOR SHED SUBMIT A SITE PLAN SHOWING EXACT OF THE SHED ON THE PLANNING DIVISION’S IS REQUIRED PRIOR TO THE AND ANY COMBUSTIBLE MATERIAL SHUT-OFF VALVE U.L. LISTED B-VENT (DBL-WALL) VENT CONNECTOR PIPE APPROVED THE DISCHARGE PIPE NO 24"OR LESS THAN 6"ABOVE DO NOT REDUCE PIPE DRAINLINE SHALL BE METAL WATER HEATER INS- (IN-HOUSE OR GARAGE) SHALL EXTEND TO EXTERIOR 1/4"PER FOOT DRAIN LINE APPLIANCE VALVE WITH FLEX-CONNECTOR,LENGTH36" SHALL BE RESPONSIBLE FOR THE ACTUAL DESIGN OF EARTHQUAKE FIELD INSPECTOR LOCATED IN GARAGE THAN ALL BURNERS AND IGNITION DEVICESMUST BE AT LEAST 18" ABOVE THE FLOOR. REFER TO NOTES ON PAGE 4 OF 4. Rev: 12/28/22 Page 1 of 4 MINIMUM 5'-0" 4' -0" MI N I M U M Tankless water heater requirements on reverse side CITY OF SANTAANA& B It is unlawful for a person to install, remove, or replace or cause to be installed, removed, or replaced a water heater without first obtaining a permit from the City. 901 E Myrtle St Unit# 2 - 1011181606/27/2024 SNUG SPACER REQUIRED BETWEEN THE WATER INSULATION BLANKET, LEAVE WRAPPED AROUND TANK AND SNUG SPACER PROVIDED BETWEEN THE WATER HEATER ANDWALL, WITHIN UPPER 1/3 & LOWER 1/3 OF ITS VERTICAL DIMENSION. SCREW WITH WASHER (FOR CONCRETE WALLS,SUBSTITUTE 1/4" EXPANSION BOLTS HEATER THAT IS ADJACENT TO A WALL. TANK FEET NEED TO BE BOLTED TO THE FLOOR AND THE HEATER HOOKED STEEL 2X4 TO CREATE SNUG FIT BETWEEN OF BRACING FOR Tankless water heaters are becoming a popular, energy-efficient replacement for standard tank-type heater. When installing a tankless water heater there are many things to consider. CAUTION: Manufacturer’s installation instructions often require special venting materials and specific installation practices. NOTE: Most installations require larger combustion air openings/ducts to be installed. BEWARE: Typical tankless water heater gas demands require gas pipe sizes to be significantly increased or additional dedicated piping, from the gas meter to the water heater, to be installed. The following items will need to be provided to the inspector at the time of the initial water heater inspection: 1.Water heater and venting material manufacturers’ installation instructions. 2.Calculations/drawings for the increased gas demand. TANKLESS WATER HEATERS 901 E Myrtle St Unit# 2 - 1011181606/27/2024 CITY OF SANTA ANA CITYWIDE DESIGN GUIDELINES Figure 6-49: Locate accessory structures to the rear of a property 1. Mechanical equipment such as air-condition units, utility meters, transformers, water heaters, satellitedishes, etc. may not be located on the front elevation. On new homes or when additions are proposed, water heaters should be located within a building'sfoot print. Water heater enclosures are discouraged. When used, enclosures should be architecturallycompatible with the primary structure and fully enclosed. Solar panels should not directly face to the street and should be installed in recesses into the roofstructure whenever possible. Solar panels should be fully integrated into the roof structure. When possible, consider the installation of solar panels on accessory structures, patios or ground Figure 6-50: Water heater enclosures should be architecturally compatible with the house. APPROPRIATE INAPPROPRIATE Street Street APPROPRIATE INAPPROPRIATE 901 E Myrtle St Unit# 2 - 1011181606/27/2024 NOTES: CPC Installation in Residential Garages (1)Gas utilization equipment inresidential garages and in adjacentspaces that open to the garage andare not part of the living space of adwelling unit shall be installed sothat all burners and burner-ignitiondevices are located not than less18 inches above the floor unlesslisted as flammable vapor ignition protected so it is not subject tophysical damage by a moving separate, enclosed space havingaccess from only out-side of thegarage, such equipment may beinstalled at floor level, providing therequired combustion air is taken be provided and installed in 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 901 E Myrtle St Unit# 2 - 1011181606/27/2024 2% W G 5% 5% 5% 5% 2% 2% 2% 5% 2% 2% 5% 5% 2% 2% 2% 5%5% 5% 5% 2% 2% 2% 2% W G 5% 5% 5% 5% 2% 2% 2% 5% 2% 2% 5% 5% 2% 2% 2% G W 2% 2% 2% 5% 2% 5% 5% 5%2% 2% 2% 1 (N) ELECTRICAL SUB-PANEL 200 AMP WITH 225 AMP BUS RATING FOR ADU 2 PERIMETER FENCE / BLOCK WALL 4 5 6 7 8 9 10 11 12 (E) WALK WAY LANDSCAPE (E) TREE (N) CONSUMER TANK WITH/ HEAT PUMP (E) GATE 17 (N) HEAT PUMP UNIT ON 3''. THK CONCRETE PAD (E) MAIN HOUSE ELECTRICAL PANEL V.I.F (E) WATER METER (N) ELECTRICAL METER FOR ADU (E) GAS METER V.I.F 3 ROOF LINE ABOVE (N) LANDING 18 (N) GAS METER (N) WATER METER (1" MINIMUM PER CITY REQUIREMENTS) (E) A/C UNIT V.I.F (E) POST 13 14 15 16 19 WOOD POST, SIZE PER STRUCT 20 21 1-HR FIRE RESISTANT EAVE PROJECTION SEE DETAIL 05/AD.20 & 02/AD.20 PROVIDE 2-2X FULL HEIGHT FIRE BLOCKING FROM TOP PLATE TO UNDERSIDE OF EXISTING ROOF SHEATHING, NO VENT HOLE ALLOWED. 22 1-HR FIRE RATED WALL, SEE SHEET 02/AD20 FOR DETAIL. 23 (N) DRIVE WAY DRAINAGE DIRECTION AND SLOPE PROPERTY LINE CORNER POINTS AND ELEVATION DATUM #KEYNOTE CALLOUTS EXISTING TO BE REMAINED AND NEW CONSTRUCTION EXISTING TO BE DEMOLISHED F.S.D F.S.L FIRE SEPARATION DISTANCE FIRE SEPARATION LINE (IMAGINARY PROPERTY LINE) 1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE- WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE AS- BUILT INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS REQUIRED. 2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, PPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. 5. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES. 6. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. 7. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. 1. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 2. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 3. PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. 4. FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. 5. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND AMENDMENTS. 6. A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. 7. WATER HEATER MUST BE STRAPPED TO WALL. 8. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 9. CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT THERE IS NO TRACEOF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. 10. SHEARWALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARD LISTED IN CH.6 & CH.7 CRC 11. UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. 12. UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE TV. AND TELEPHONE 13. ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED 14. BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED RECEPTACLE OUTLETS. 15. PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT OPENABLE WINDOW. 16. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC 17. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. 18. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. 19. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. 20. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. 21. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND THE DESIGNER/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. 22. VERIFY WITH AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. 23. WHEN SOLAR PANEL IS REQUIRED, SOLAR PLANS SHALL BE REVIEWED AND APPROVED BY BUILDING DIVISION PRIOR TO ROOF SHEATHING INSPECTION. 24. FOR EACH DWELLING UNIT, INSTALL A LISTED RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT (40 AMP) COMPLIANCE WITH SECTION 4.106.4.1 25. THE SERVICE PANEL OR SUB-PANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE". THE PROPOSED PROJECT IS A NEW 799 SF DETACHED ADU, CONSIST OF: • 2 BEDROOMS, 2 BATHROOMS. • KITCHEN, DINING, LIVING ROOM. • 206 SF COVER PATIO, 19 SF LANDING, 66 SF COVER PORCH • NEW CENTRAL AC, NEW HEATPUMP WATER HEATER, NEW AIR HANDLERS. • DUAL-GANG METER, 225 APMS SUB-PANEL. THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE . SANTA ANA, AMENDMENTS AND MUNICIPAL CODE. LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92701 THE DESIGN OF THE ACCESSORY DWELLING UNIT SHALL BE ARCHITECTURALLY COMPATIBLE WITH THE MAIN DWELLING UNIT, WITH ALL DESIGN. THE DESIGN, ROOF PITCH, DEPTH OF EAVE, COLOR, MATERIAL AND TEXTURE OF THE ROOF SHALL BE SUBSTANTIALLY THE SAME AS THE MAIN DWELLING UNIT. PL 56.58' PL 1 0 0 . 0 2 ' PL 64 . 87 ' PL 14. 28' PL 3 5 .46' PL 42.84' (E) 42'-11 1/2" (E ) 25 ' - 9 " (E ) F R O N T S E T B A C K 22 ' - 5 1 / 2 " (E ) S E T B A C K 4' - 1 0 " (E) 29'-0" 27 ' - 0 " (E ) 27 ' - 0 " (E) SETB A C K 8'-1" (E) 17'-0" (E) 5'-0" (E ) 3' - 0 " (E) 23'-8" (E) 21'-0" (E ) 19 ' - 1 " (E) 20'-1" (E) 2- CAR GARAGE 420 SF SINGLE FAMILY RESIDENCE 1,044 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 STREET CURB & GUTTER CENTERLINE OF STREET CENTERLINE OF STREET (E ) 22 ' - 6 " (E) POWER POLE 1 2 2 2 8 4 4 4 6 9 9 9 9 3 15 16 7 5 2 9 9 9 9 4 21 2 2 9 (E ) 1' - 0 " (E) 18'-8" (E) 4'-9 1/2" (E) 1'-0" (E) 1'-0" (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) SET BACK 5'-9 1/2" (E ) 3' - 1 0 " (E) 28'-0" (E ) 1' - 0 " (E ) 1' - 0 " (E) 19'-3 1/2" (E ) 22 ' - 9 " (E ) 4' - 0 " (E ) 3' - 0 " (E ) 6" TO C E N T E R L I N E 30 ' - 0 " (E ) 20 ' - 0 " E MYRTLE ST S S T A N D A R D A V E ALLEY (E) PORCH PL 56.58' PL 1 0 0 . 0 2 ' PL 6 4 . 87 ' PL 14. 28' PL 3 5 .46' PL 42.84' (E ) 1' - 0 " (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" (E ) T O C E NT E R L I N E 30 ' - 0 " (E) 42'-11 1/2" (E ) 25 ' - 9 " (E ) F R O N T S E T B A C K 22 ' - 5 1 / 2 " (E ) S E T B A CK 4' - 1 0 " (E) 2- CAR GARAGE 420 SF SINGLE FAMILY RESIDENCE 1,044 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 (E) 1'-0" (E) 1'-0" (E ) 1' - 0 " TO C E N T E RL I N E 10 ' - 0 " (E) SETBACK 8'-1" (E) 17'-0" (E) TOCENTER LINE 30'-0" (E) PORCH STREET CURB & GUTTER CENTERLINE OF STREET CENTERLINE OF STREET (E ) 4' - 0 " (E ) 3' - 0 " (E ) 6" (E ) 22 ' - 6 " (E) 5'-0" (E ) 3' - 0 " (E) 19'-3 1/2" (E) 23'-8" (E) 4'-0" (E) 3'-0" (E) 6" (E) POWER POLE (E ) 19 ' - 1 " (E) 20'-1" 1 2 2 2 8 44 4 6 9 9 9 9 3 15 16 7 5 2 9 9 9 1'-0" 1' - 0 " 1' - 0 " 1'-0" 1' - 0 " DI S T A N C E 6' - 0 " F. S . D 3' - 0 " F. S . D 3' - 0 " DISTANCE 5'-0" 20 20 20 4 F.S.L 13'-10"10'-2" 13'-5" (E) SETBACK 18'-0" (N) DETACHED ADU - UNIT 2 799 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 (E) SETBACK 5'-9 1/2" 21 22 22 F. S . D 3' - 0 " F. S . D 3' - 0 " 22 2 AD.20 14 (E) 1'-0" (E) 18'-0" (E) 4'-9 1/2" 9 9 9 3' - 1 0 " 41 ' - 0 " 22 9 2 AD.20 19 19 17 13 MIN. 2'-0" 18 23 34 ' - 6 " 10 10 12 11 (E ) 1' - 0 " DI S T A N C E 6' - 0 " (N) WALKWAY 9 E MYRTLE ST S S T A N D A R D A V E 4' - 0 " 12'-10"1'-0" 4'-0" ALLEY 20 9 29'-0" 1'-0" ADU SETBACK 5'-0" (N) COVER PATIO 206 SF 19 (N) COVER PORCH 66 SF F.S.L (N) LANDING 19 SF HB HB 1 1 JURISDICTION HAVING AUTHORITY: CITY OF SANTA ANA, CA 92701 LEGAL DESCRIPTION: N TRACT 2482 BLK, LOT 72 ASSESSORS PARCEL NO. APN: 404-011-11 IN FLOOD ZONE FEMA SHFA'S: FLOOD ZONE X CONSTRUCTION TYPE: V-B ZONING: R1 (SINGLE FAMILY RESIDENTIAL) OCCUPANCY GROUP: R3/U SPRINKLERS: EXISTING: NO ADU: NO (E) MAINHOUSE MAX HEIGHT: 15 FT (ALLOWABLE: 27 FT) ADU MAX. HEIGHT: 14'-6" FT (ALLOWABLE: 20 FT) ADU REQUIRED SETBACKS: FRONT: 4 FT SIDE: 4 FT REAR: 4 FT DISTANCE TO (E) STRUCT: 6 FT LOT SIZE: 6,554 SF EXISTING: (E) MAIN HOUSE LIVING AREA: 1,044 SF (E) GARAGE: 420 SF EXISTING TOTAL: 1,464 SF NEW CONSTRUCTION (N) DETACHED ADU: 799 SF (EXEMPT) (N) COVER PATIO: 206 SF (N) COVER PORCH: 66 SF (N) LANDING: 19 SF NEW TOTAL: 1,090 SF MAXIMUM LOT COVERAGE: 35% OVERALL LOT COVERAGE: (1,071 SF + 1,464 SF) / 6,554 SF = 38.7% LOT COVERAGE AND USE INTENSITY MAXIMUM ESTABLISHED IN ZONING DISTRICT MAY BE EXCEEDED TO PERMIT AN ADU UP TO EIGHT HUNDRED (800) SQUARE FEET IN SIZE PARKING REQUIREMENT NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN ACCORDANCE WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN ACCESSORY DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING DISTANCE OF PUBLIC TRANSIT. TOTAL PARKING REQUIRED (E) MAIN HOUSE: 2 STALLS (N) ADU 0 STALL TOTAL: 2 STALLS PROJECT LOCATION IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATE DELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 A.00 SITE PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 SHEET INDEX SITE PLAN KEYNOTES GENERAL NOTES PROJECT DATA ARCHITECTURAL A.00 SITE PLAN A.01 CAL GREEN CODE A.02 CAL GREEN CODE A.03 GENERAL DETAILS A.04 EXISTING - FLOOR PLAN A.05 PROPOSED ADU FLOOR & ROOF PLAN A.06 PROPOSED ADU SECTIONS & ELEVATIONS A.07 PROPOSED ADU ELECTRICAL PLAN A.08 ROOM FINISH & DOOR/WINDOW SCHEDULE & INTERIOR DETAILS AD.10 ARCHITECTURAL DETAILS AD.20 ARCHITECTURAL DETAILS D.01 DRAINAGE PLAN T24.1 TITLE 24 T24.2 TITLE 24 (CONT.) T24.3 TITLE 24 (CONT.) STRUCTURAL S-0.10 GENERAL NOTES & REQUIREMENTS S-0.11 GENERAL NOTES & REQUIREMENTS & SOIL REPORT S-0.12 SOIL REPORT S-0.13 SOIL REPORT S-0.14 SOIL REPORT S-0.20 TYPICAL DETAILS S-1.0 FOUNDATION PLAN S-2.0 FRAMING PLAN SD1.0 FOUNDATION DETAILS SD2.0 STRUCTURAL DETAILS APPLICABLE CODE SPECIAL NOTES 1" = 10'-0" 1EXISTING SITE PLAN 1" = 10'-0" 2PROPOSED SITE PLAN SYMBOL LEGEND CONSTRUCTION NOTES VINCITY MAP DEFERRED SUBMITTALS SCOPE OF WORK 2.05 KW PER T24 PV SYSTEM WILL BE UNDER A SEPARATE PERMIT FOR ADU THE MAIN ELECTRICAL SERVICE PANEL RATING OF 225 AMPS. THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BURSAR A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". SOLAR PV SYSTEM MUST BE APPROVED REQ BUILDING DIVISION PRIOR ROOF SHEATHING INSPECTION. 2.05 kW PHOTOVOLTAIC SYSTEM WILL BE SUBMITTED UNDER A SEPARATE PERMIT AND SHALL BE ISSUED PRIOR TO BUILDING FRAME INSPECTION REQUEST (E) BLOCK WALL TO BE DEMOLISHED NOTE: THE APPLICANT / PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND / OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT. 1 1 Revision to 101118160 (issued on 6/25/24) REV 1 - 101121896 APPROVALS: PLNG -C. Santana BLDG - G. Huang 901 E Myrtle St Unit# 23/14/2025 AT T I C HP W/H RE F . DW W/ D AT T I C HP 1. VERIFY ALL APPLIANCE EQUIPMENT AND FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO CASEWORK FABRICATION INSTALLATION. 2. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & PAINT EXPOSED GYP. BD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BD. 3. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NON- ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. 6. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING FINISH. 7. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE HARD WIRED WITH BATTERY BACK-UP AND LOCATED (1) IN EACH BEDROOM, HALLWAYS OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM SOUND MUST BE AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER MFGR. LISTED REQUIREMENTS. 8. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING ROOMS PER CHAPTER 3 CRC. 9. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE DUCTED TO THE EXTERIOR OF THE BUILDING 10. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD REQUIREMENTS. 11. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. 12. PROVIDE TWO LAYERS OF GRADE D OR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE SHEATHING AT EXTERIOR WALLS. 13. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE OF 3½ INCHES SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) 14. ACCESS TO ATTIC FURNACE MUST BE WITHIN 20' OF UNIT AND SHALL HAVE A CONTINUOUS SOLID WALKWAY AT LEAST 24" WIDE. A SWITCH CONTROL IS ALSO REQUIRED (CMC 304.4.1) 15. DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET (4267 MM), INCLUDING TWO 90 DEGREE (1.57 RAD) ELBOWS. A LENGTH OF 2 FEET (610 MM) SHALL BE DEDUCTED FOR EACH 90 DEGREE (1.57 RAD) ELBOW IN EXCESS OF TWO. 16. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 17. WATER HEATER MUST BE STRAPPED TO WALL. 18. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. 19. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC 20. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. 21. ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(N)1A-D) A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. D. A GAS SUPPLY LINE WITH AVAILABLE CAPACITY FOR NOT LESS THAN A 200,000 BTU/HR SYSTEM. 22. ADU FINISH FLOOR ELEVATION IS NOT NOT LOWER THAN THE FINISH FLOOR OF THE MAIN HOUSE AND HIGHER 1' MINIMUM THAN BASE FLOOD ELEVATION. EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF) (N) 2X4 INTERIOR WALL (N) 2X4 EXTERIOR WALL / INFILL WITH INSULATION PER T-24 1-HOUR FIRE RATED WALL EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL IAQ FAN: ( MIN 46 CFM PER T-24 ) PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE HB 3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ BATTERY BACK UP CD 22X30 ATTIC ACCESS HEATPUMP + AIR HANDLER HEATPUMP UNIT ON PAD 3" MIN. LAUNDRY DRYER EXHAUST CEILING AIR DIFFUSER ELECTRICAL PANEL/METER PER KEYNOTE CONSUMER TANK WITH/ HEAT PUMP DOOR TYPE SEE A.08 FOR SCHEDULE WINDOW TYPE SEE A.08 FOR SCHEDULE KEY NOTE FLOOR DEPRESSION1.5'' XX XX XX 1 2 3 4 5 7 9 EXHAUST FAN FOR BATHROOM SHALL BE MINIMUM 50 CFM AND CONTAIN HUMIDISTAT (EXHAUST THROUGH ROOF). 10 EXHAUST FAN ABOVE KITCHEN GAS RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF) 11 8 (N) DUAL-GANG ELECT. METER BOX (N) ELECTRICAL SUB-PANEL 200 AMP WITH 225 AMP BUS RATING FOR ADU (N) LANDING. 1 1/2" BELOW THRESHOLD. MINIMUM 36" IN DEPTH.MIN. 2% SLOPE AWAY FROM BUILDING. (N) 22X30 ATTIC ACCESS 2'' SHOWER CURB MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL/ROOF) 6 (N) HEAT PUMP UNIT ON 3" THIK. CONCRETE PAD (N) 6X6 POST TEMPERED GLASS 12 (N) CONSUMER TANK WITH/ HEAT PUMP, DETAIL ON SHEET A.03 13 APPROVED PRE-FABRICATED SHOWER ENCLOSURES WALL PANELS WITH FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS. SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET 14 FUTURE INSTALLED FLOOR MOUNTED FOLDABLE GRAB BAR 15 2X8 BACKING FOR FUTURE GRAB BAR INSTALLATION 16 32'' MIN. CLR. INTERIOR DOOR SEE NOTE ON ''AGING-IN-PLACE'' 17 18 OBSCURED,TEMPERED GLASS 19 1HR FIRE RATED WALL, UPNPROTECTED OPENING MAX 25% WALL AREA, SEE CALCULATION ON ELEV. 01/A.06,02/A.06 20 NOT USE NOT USE 1. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. 2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. 3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT. 4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. 5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER TH AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR0IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER. ATTIC AREA: 799 SF USE BALANCE METHOD : 1/300 NET VENT AREA REQUIRE : 799/300 x 144 SQ.IN. = 383 SQ.IN LOW: USE 3 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) = 216 SQ.IN (1/3 LOW AREA OF ROOF) HIGHT: USE 3 UNITS O'HAGIN VENT (72 SQ.IN/UNIT)= 216 SQ.IN (1/3 HEIGHT AREA OF ROOF) + 10 FT RIGDE VENT (18 SQ.IN/FOOT) = 180 SQ.IN TOTAL = 612 SQ.IN 9'-11" 2' - 0 " 3'-2" 6' - 7 1 / 2 " 10 ' - 0 1 / 2 " 2' - 4 1 / 2 " 3' - 8 " 3' - 5 " 19 ' - 6 " 15'-1 1/2"8'-10"5'-4 1/2" 5' - 7 1 / 2 " 4' - 7 " 3'-10"8'-4"5'-4 1/2" B A.06 B A.06 COVER PATIO 15"15" 16 " 18 " 21'-5"9'-3" 8'-0" 5' - 0 " 5'-0" 14 ' - 9 " A.06 2 A. 0 6 3 A.06 1 A. 0 6 4 8' - 8 1 / 2 " 11'-9 1/2" 3' - 6 " 5' - 3 " 9' - 8 " 9'-3" 5'-0" A A.06 A A.06 SD CDSD CDSD SD 30" 3'-0" 6' - 0 " 1. 5 ' ' 1.5'' 1 2 3 5 3 3 3 4 7 5' - 0 " 21'-0 1/2" 14 ' - 1 " A B B C 30'' CLR 30'' CLR 6 11 3 3 11 16 99 7 10 13 5 14 3'-5 1/2" 36'' CLR. FRONT OF PANEL 15 14 15 BEDROOM#1 KITCHEN LIVINGBEDROOM#2 W.I.C BATH#1 BATH#2 PORCH CLOSET 4' - 6 1 / 2 " EE&RO EE&RO 18 18 19 19 2 AD.20 2 AD.20 88 2 AD.20 1.5" 4 11 19 COVER PORCH 8 8 8 8 12 3 10 FT MIN. 14 ' - 2 " PHOTO- ELECTRIC TYPE MIN. 20FT20'-3 1/2" MIN. 3'-0" 13 11 13 2 1 21 HB HB 4'-11 1/2"4'-11 1/2" 2'-10 1/2" 6 15 1515 10'-2" 24 ' - 5 1 / 2 " 1 1 B A.06 B A.06 1'-0" 1'-0" 6' - 2 " WALL LINE BELOW WA L L L I N E B E L O W WA L L L I N E B E L O W WALL LINE BELOW WA L L L I N E B E L O W A.06 2 A. 0 6 3 A.06 1 A. 0 6 4 ROOF MATERIAL COVERING CLASS "A", TO MATCH WITH EXISTING ROOF (EXISTING ROOFING MATERIAL TYPE: ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537). OVER PLYWOOD SHEATING OVER RAFTERS PWE STRUCTURAL DWGS. 4: 1 2 4: 1 2 A A.06 A A.06 O'HAGIN VENT 72 SQ.IN TYP. O'HAGIN VENT 72 SQ.IN TYP. 3FT MIN. 3' - 0 " 3FT MIN. 3'-0" O'HAGIN VENT 72 SQ.IN TYP. FUTURE SOLAR ZONE 140 SF FUTURE SOLAR ZONE 110 SF UNDER SEPARATE PERMIT POST BELOW POST BELOW 2 AD.20 2 AD.20 2 AD.20 1' - 0 " 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1' - 0 " 1'-0" RIDGE VENT 10'-0" 4:12 4:12 1' - 0 " POST BELOW POST BELOW PO S T B E L O W PO S T B E L O W WA L L L I N E B E L O W 1'-0" 4:12 4:12 4:12 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 A.05 PROPOSED ADU FLOOR & ROOF PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 1/4" = 1'-0"1PROPOSED ADU FLOOR PLAN 1/4" = 1'-0"2PROPOSED ADU ROOF PLAN ROOF VENTILATION NOTES: (CRC R806)PLAN KEYNOTES FLOOR PLAN NOTES PLAN LEDGEND ROOF VENTILATION CALCULATION ROOF PLAN GENERAL NOTES 1. ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & PER THE INSTALLATION OF ROOF COVERING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 2. PROJECTIONS LESS THAN 5'-0" (HOUSE WITH NO SPRINKLER) TO PROPERTY LINE TO BE 1-HOUR CONSTRUCTION, TYP. 3. ROOF VENT : SEE ROOF VENTILATION CALCULATION. 901 E Myrtle St Unit# 23/14/2025 1. PROVIDE FIRE BLOCKING IN CONCEALED SPACES 10' O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES, CRC R302.11. 2. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" TO THE EXPOSED GROUND SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY, CRC R317.2(2). 3. ALL WALLS TO BE SMOOTH FINISH U.N.O. 4. CONTRACTOR TO INCLUDE ALL FINISH AND COLOR SPECIFIED BY OWNER AND INTERIOR DESIGNER. 5. CONTRACTOR TO VERIFY W/ OWNER'S INTERIOR DESIGNER FOR MATERIAL SELECTION AND COLOR PRIOR TO FINAL PRICING AND CONSTRUCTION. 6. MIN. 3/8" CDX PLYWOOD THROUGH-OUT @ OUTSIDE FACE OF WALL 7. CONTRACTOR TO INCLUDE INSULATION OF CLOSET ORGANIZER. (SELECTED BY OWNER) 8. CONTRACTOR TO VERIFY ALL OWNER'S APPLIANCE MANUAL SPEC. PRIOR TO CONSTRUCTION. 9. DESIGN BUILT CABINET TO FIT 10. ALL INTERIOR, DOOR, WINDOW SIDE, HEAD AND SILL TO BE MOLDING 11. EXTERIOR CONCRETE LANDING TO COMPLY 2022 CRC R311.3 A. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A DIMENSION OF NOT LESS THAN 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT). B. LANDINGS AT THE REQUIRED DOOR SHALL NOT MORE THAN 1 1/2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. EXCEPTION: THE LANDING SHALL BE NOT MORE THAN 7 3/4 INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING 12. GROUND ADJACENT TO THE FOUNDATION SHALL FALL A MINIMUN OF 8 INCHES WITHIN THE FIRST 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE FOUNDATION WALL. (CRC R401.3) XX DOOR TYPE, SEE SCHEDULE A.10 WINDOW TYPE, SEE SCHEDULE A.10 XX KEY NOTE XX LEGEND EE&RO EGRESS ESCAPE AND RESCUE OPENING 3 4 7 8 5 6 ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & TEXTURE TO MATCH EXISTING HOUSE. STUCCO, PAINT AND MATERIAL TO MATCH EXISTING1 2 FASCIA & TRIMMING -PAINT TO MATCH EXISTING HOUSE 2 1/2" VINYL MOLDING TRIM FOR ALL WINDOWS TO MATCH EXISTING HOUSE CONCRETE LANDING ROOF VENTS WOOD POST TEMP. OBSCURED GLASS 9 TEMPERED GLASS A 2x10 RIDGE BOARD PER STRUCT. B 2x8 ROOF RAFTER PER STRUCT. C 2x6 CEILING JOISTS PER STRUCT D CONCRETE SLAB PER STRUCT. E FOOTING PER STRUCT. F 2x4 STUD WALL PER STRUCT. G ATTIC INSULATION PER T-24 H WALL INSULATION PER T-24 I WEEP SCREED FOR STUCCO, 2" ABOVE PAVED AREAS, 8" ABOVE NATURAL GRADE J K DEPTH OF EAVE TO MATCH MAIN DWELLING, TYP. O'HAGIN VENT 72 SQ.IN TYP. L 1HR FIRE RESISTANCE EAVE, SEE DTL 05/ AD.20 M 1-HR FIRE RATED WALL, SEE SHEET 02/AD20 FOR DETAIL. ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 14' -6" 6' - 8 " 1'-0" 1'-0" 1'-0" 4:12 4:12 4: 1 2 2' - 8 " 4' - 0 " 5'-0" 6' - 8 " 5'-0" 8" 10 ' - 0 " AD U M A X . H E I G H T 14 ' - 6 " 9 1 4 6 EE&RO EE&RO 4 A 5 2 3 6 F.S.D = 4 FT (3FT<F.S.D<5FT) UNPROTECTED OPENING MAXIMUM 25% WALL AERA. WALL AREA = 262 SF, OPENING = 20 SF. 20 / 262 = 7.6 % <25% (OK) WINDOW = 20 SF 8 4:12 1 1 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 14' -6" 6' - 8 " 4:12 4:12 2' - 0 " 4' - 8 " 1'-0"1'-0"2'-0"2'-0"1'-0" F.S.D 3'-0" F.S.D 3'-0" TO (E) STRUCT 6'-0" (E ) M A I N H O U S E F. S . L 10 ' - 0 " 8" (N ) A D U M A X . H E I G H T 14 ' - 6 " 3 2 1 B 3'-0" 6' - 8 " 1 8 55 6 9 7 4 4: 1 2 1 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 14' -6" 10 ' - 0 " 4: 1 2 4:12 4:12 1'-0" 6' - 8 " 4' - 8 " 2' - 0 " 8" 7' - 0 " 3' - 6 " 3' - 6 " (N ) A D U M A X . H E I G H T 14 ' - 6 " C B 6 1 F.S.D = 4 FT (3FT<F.S.D<5FT) UNPROTECTED OPENING MAXIMUM 25% WALL AERA. WALL AREA = 414 SF, OPENING = 30.60 SF. 30.60 / 414 = 7.4% <25% (OK) 2'-6" 3'-6" WINDOW = 12,25 SF WINDOW = 5 SF 2 4'-0" 7 4 4 PR O P E R T Y L I N E 3 1'-0" 1 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 14' -6" 2'-0"2'-0"1'-0" 1'-0" 4: 1 2 COVER PATIO 8" 10 ' - 0 " (N ) A D U M A X . H E I G H T 14 ' - 6 " 2 1 8 3 1'-0"3'-10" TO PROPERTY LINE 4'-10" (E ) M A I N H O U S E F.S.D 3'-0" F. S . L 5 PR O P E R T Y L I N E 2 8 TYP. 4: 1 2 1 1 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 14' -6" COVER PATIO 4:12 1'-0"R38-INSULATION R19-INSULATION 10 ' - 0 " 8" AD U M A X . H E I G H T 14 ' - 6 " D EE CG B J J AD.10 6 1 AD.10 1 AD.20 A BATH#2 BATH#1 LIVING KITCHEN CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING R15-INSULATION R15- INSULATION 1'-0" K 4:12 1 ADU F.F. 0' -8" ADU TOP PL 10' -8" ADU MAX. HEIGHT 14' -6" CEILING SOFFIT REF.CLOSET DE E F H G C F H I 1 AD.20 1'-0"1'-0" J B G CR38-INSULATION R19-INSULATION 2 AD.20 M A L BEDROOM#1 KITCHEN CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING R15- INSULATION R15- INSULATION K LAUNDRY AD U M A X . H E I G H T 14 ' - 6 " 10 ' - 0 " 8" 4:12 4:12 1 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 A.06 PROPOSED ADU SECTIONS & ELEVATIONS (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 1/4" = 1'-0"1PROPOSED ADU NORTH ELEVATION 1/4" = 1'-0"4PROPOSED ADU WEST ELEVATION 1/4" = 1'-0"2PROPOSED ADU SOUTH ELEVATION 1/4" = 1'-0"3PROPOSED ADU EAST ELEVATION 1/4" = 1'-0"BPROPOSED SECTION B-B1/4" = 1'-0"APROPOSED SECTION A-A ELEVATION KEYNOTES ELEVATION & SECTION NOTES SECTION KEYNOTES 901 E Myrtle St Unit# 23/14/2025 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N S-0.20 TY P I C A L D E T A I L S EXTERIOR SHEATHING SEE ARCH. FOR INSULATION AND MEMBRANE STEEL ANGLE SCHEDULE SIZE SPAN MAX. L4x3 1/2x3/8 L6x3 1/2x1/2 L7x4x5/8 8'-0" 14'-0" 16'-0" ADD 9 GAUGE WIRE JOINT REINF. @24" O.C. VERTICAL FOR BUILDING IN SEISMIC DESIGN CATEGORIES C, D, E, F. FERO PAC-TIE WITH 2-#6 x 2" DECK SCREW AND WASHERS AS FOLLOWS: - TYPICAL AT 16" HORIZONTAL AND AT 24" VERTICAL - AROUND OPENINGS AT 12" HORIZONTAL AND AT 16" VERTICAL - NOT MORE THAN 12" FROM EDGE OF OPENINGS. - LOCATE ROW OF TIES MAX 12" ABOVE BEARING LEVEL AND 8" FROM TOP OF WALL. LLV STEEL ANGLE SUPPORT 3'-6" VENEER HEIGHT MAX AND NEED TO EXTENT AND BEAR ON EACH SIDE OF OPENING 4" MIN. SEE SCHEDULE FOR SIZE STUD WALL PER PLAN BEAM OR HEADER PER PLAN 1/2" DIA. LAG SCREW @12" O.C. WITH 2.5" MIN. EMBED TO BEAM OR HEADER OPENING VENEER TO WOOD WALL 4 2 3 5 6 TY P I C A L D E T A I L S 1 810 11 7 8 9 12 CONCRETE FLOOR CONDITION WOOD FLOOR CONDITION 1' MIN.PARTIAL SHEET AT WALL END ONLY 1' MI N . WH E R E RE Q ' D 7" MI N . STAGGER HORIZ. PANEL JOINTS, TYP OR USE FULL HEIGHT SHEETS WHERE POSSIBLE FULL SIZE PLYWOOD SHEET TYP. U.O.N. END POST AT HD EDGE NAIL TO HOLD DOWN END POST ANCHOR BOLTS PER SHEAR WALL SCHEDULE EDGE NAIL TO SILL BLK'G AT PANEL EDGES SAME SIZE AS PANEL EDGE STUD WITH STAGG. E.N. FIELD NAILING @12" O.C. EDGE NAIL AT PANEL EDGES TYP. STUDS PLYWOOD FACE GRAIN PARALLEL TO STUD EDGE NAIL TO SOLE PLATE SOLE PLATE NAILING A35 PER SHEAR WALL SCHEDULENOTES: 1.PROVIDE STAGGERED NAILING AT ALL PANEL EDGES. 2. STUDS ARE SPACED @ 16" O.C. MAX. U.O.N. 3. PROVIDE 1/8" GAP BETWEEN ADJACENT PANELS. EDGE NAIL TO TOP PLATES STAGGER NAILS EDGE NAIL AT ALL VERTICAL PANEL SPLICES (STAGG.). POST SIZE AT SPLICE PER SHEAR WALL SCHEDULE NOTES. SHEAR WALL FRAMING ELEVATION 1/ 2 " GA P FLOOR LINE H TOP OF PARTITION PARALLEL TO JOISTS 1/ 2 " GA P FLOOR LINE H TOP OF PARTITION PERPENDICULAR TO JOISTS 1/2 "GAP TOP OF PARTITION TO CONC. SLAB 1/ 2 " GA P 4x W/ 1/2" Ø HILTI KH-EZ @48" O.C. W/ 5" EMBED EA SIDE DBL. TOP PLATES CEILING WHERE OCCURS SLAB PER PLAN 2-16d TOE NAIL 2x4 FLAT @ 48" O.C. DBL. TOP PLATES 2x6 BRACING W/ (3)16d EA END @ 8'-0" WHERE WALL IS: 2x4 AND H> 14'-0" 2X6 AND H> 22'-0" PROVIDE 2x6 CONT. @ MIDSPAN WHERE BRACE EXCEEDS 6'-0" W/(2) 16dCEILING WHERE OCCURS SIMPSON DTC (SLOT VERTICAL) AT EA JOIST OR RAFTER DBL. TOP PLATES CEILING WHERE OCCURS SIMPSON DTC (SLOT VERTICAL) CLIP @ EA RAFTER CEILING WHERE OCCURS SIMPSON STCT CLIP (SLOTS VERTICAL) WHERE REQUIRED @ EA RAFTER PARTITION WALL (NON-BEARING/ NON-SHEARWALL) FRAMING AT NON BEARING WALLS NON BEARING WALLS FLOOR JOIST PER PLAN SIMPSON Z CLIP EA. END 2X BLOCKING @16" O.C. SIMPSON Z CLIP EA. END 2X BLOCKING @16" O.C. WALL PARALLEL TO JOIST WALL PERPENDICULAR TO JOIST NON BEARING WALLS PROVIDE DOUBLE JOISTS UNDER NON BEARING WALLS NON BEARING WALLS PROVIDE FULL HEIGHT BLK'G UNDER NON BEARING WALLS 2x SAWN LUMBER 1 3/4" ENGINEERED LUMBER WEB STIFFENER WALL PARALLEL TO JOIST OPTION NOTES: 1. NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING. 2. PLYWOOD OSB PIECES SHALL CONTAIN NOT LESS THAN 8 SQ. FT. NOR BE LESS THAN 2-0" WIDE. 3. MAXIMUM UNSUPPORTED SHEATHING TO BE 24". 4. FRAMING AT ADJOINING PANEL EDGE SHALL BE 3" NOMINAL OR WIDER AND NAILS AT ALL PANEL EDGES SHALL BE STAGG. WHERE PANEL EDGE NAILING IS SPECIFIED AT 2 1/2" 0.C. OR LESS. 5. ALL PANEL EDGES OF THE FLOOR SHEATHING SHALL HAVE APPROVED T AND G JOINTS OR SHALL BE SUPPORTED BY BLK'G. PER IBC/CBC TABLE 2304.8 (3) FOOTNOTE D. 6. DIAPHRAGM BOUNDARY SHALL BE SUPPORTED BY FRAMING MEMBERS WITH BOUNDARY NAILING. SECTION A-A PLAN 1/8" GAP 4'-0"x8-0" SHEETS, STAGG. AS SHOWN FIELD NAINILG SHEATHING EDGE NAILS 2x MIN. FRAMING DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT DISCONTINUOUS EDGE W/2x MIN. FRAMING BLK'G. CONT. EDGE W/2x MIN. BLK'G. AT BLOCKED DIAPHRAGM JOIST PER PLAN CONT. EDGE W/O BLK'G. @ UNBLK'G. DIAPHRAGMEDGE NAILING STAGG. AA PANEL JOINT ROOF OR FLOOR SHEATHING LAYOUT 4' - 0 " M A X 1" MIN PENETRATION SECTION OF DOUBLE JOISTS PLAN VIEW NOTES: SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF OPENING WOOD JOISTS PER PLAN SHEATHING PER PLAN MSTA30 W/2x BLOCK TYP. @ CORNER DOUBLE JOISTS TAIL JOIST HANGER PER PLAN EDGE NAILING COMMON NAILS @ 6" O.C. EACH FACE TOP AND BOTTOM WEB STIFFENER AT HANGER (I-JOIST ONLY) TYP. FLOOR AND ROOF OPENING 1. 1/2" 3D MAX. L/3 MIN. D MIN. D/ 4 MA X . 2" M I N 2" M I N D/ 5 MA X . D ℄ JOIST AND HOLE NOTE: 1. D = DEPTH OF JOIST OR BEAM D1= STUD WIDTH L = CLEAR SPAN 2. PERDRILL CORNERS OF NOTCHES 3. NOTCH MAY OCCUR TOP OR BOTTOM, NOT BOTH. 4. NOTCHES AND HOLES ARE NOT ALLOWED IN CANTILEVER PORTION OF JOISTS. 5. MAX. ALLOWED IS A COMBINATION OF TWO NOTCHES AND/OR HOLES IN L/3 SPAN. D/ 6 MA X . RAFTER, JOIST OR BEAM DRILLING HOLES AND NOTCHING OF THE JOIST ROOF TRUSSES OR RAFTER PER PLAN NOTE: - USE PRE-FAB. STEP-DOWN TRUSSES PERPENDICULAR TO ROOF TRUSSES IN-LIEU OF 2x JACK RAFTERS 2x4 OR 2X6 RAFTERS @ 24" O.C. MAX. MAX. SPAN: 2x4 = 4'-0" 2x6 = 8'-0" 2x VALLEY PLATE W/(3) 16d INTO EACH RAFTER OR TRUSS ADD 2x4 STRUT FROM JACK RAFTER TO RAFTER OR TRUSS BELOW TO LIMIT OVER FRAMING RAFTER SPAN 2x RIDGE BOARD W/ DEPTH GREATER THAN JACK RAFTER OVER FRAMING INTERSECTION w/ POST INTERSECTION w/o POST OUTSIDE CORNER w/ POST OUTSIDE CORNER w/o POST NOTE: SEE FRAMING PLAN FOR SHEAR WALL LOCATIONS, ORIENTATIONS AND SCHEDULE REFERENCES 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD PLYWOOD AT DOUBLE-SIDED WALL POST AT PER PLAN 16d @ 12" O.C. POST AT PER PLAN 2x OR 3x STUD AS REQ'D., TYP. PER S.W. SCHED. PLY. CONT. THRU WALL INTERSECTION ATDOUBLE-SIDED WALL 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD DOUBLE 2x, MIN. 16d @ 12" O.C. SHEAR WALL/ INTERSECTION DOUBLE STUDS 16d @24" O.C. TYP. WALL INTERSECTION DOUBLE TOP PLATES SILL PLATE NOTE : WHERE NOTCH IS GREATER THAN 1" PROVIDE 10 GA STRAP W/ WIDTH SAME AS DBL TOP PL.TOP PL OF SHEAR WALLS SHALL NOT BE NOTCHED UNLESS SPECIFICALLY DETAILED. NOTE : WHERE DEPTH OF NOTCH "B" OS GREATER THAN D/5 PROVIDE ANCHOR BOLT EA SIDE OF NOTCH PER END REQUIREMENT. NO MORE THAN ONE NOTCH IS PERMITTED IN EVERY 12'-0" @ SHEAR WALL 5" MIN. 9" MAX. 5" MIN. 9" MAX. 5" MIN. 9" MAX. 2D MIN. D D/ 2 D/ 2 "B" 8" MAX @ SHEAR WALL "B " D/ 3 8) 16D SIDE OF NOTCH (4PL) 5" 3" MAX.5"NOTCH D/ 2 MA X . 2D MIN. D/ 3 D/ 2 D/ 2 D DRILLED HOLE END OF SILL PL END OF SILL PL PLATE NOTCH AT NON SHEAR WALL NON BEARING STUDS BEARING STUDS NOTES: 1. NOTCHING AND BORING SHOULD NOT OCCUR IN SAME STUD SECTION 2. NO MORE THAN TWO SUCCESSIVE DOUBLE STUDS MAY HAVE 60% MAX BORING HOLES 5/8" MIN. DISTANCE TYP. ALL STUD 5/8" MIN. DISTANCE TYP. ALL STUD 1-1/2" 1-1/2" 40% MAX. STUD WIDTH NOTCH 60% MAX. STUD WITH BORE NOTCH SCHEDULE 25% 40% 60% 7/8" 1-3/8" 2" 2 x 4 % OF STUDS NOTCH/BORE 1-3/4" 2-1/8" 4-1/4" 2 x 8 60% MAX. STUD WITH BORE STUD NOTCHING/BORING LIMITS 1-3/8" 2-1/8" 3-1/4" 2 x 6 POST SEE PLAN OR SOLID BLK'G. SEAT ON HEADER (2)2x TOP PL'S PROVIDE FULL WIDTH BLK'G. UNDER POST ABOVE JOIST SEE PLAN FOR DIRECTION POST SEE PLAN SIMP. A34 EACH SIDE 2x SOLE PL. PLYWOOD SHEATHING SEE PLAN BLOCKING AT POSTS/TRIMMERS13 NOTES: 1. INSTALL SOLE PLATE ANCHORAGE AS SHOWN AND AT SPACING INDICATED IN WOOD SHEARWALL BASE CONNECTION SCHEDULE. 2. STAGGER ANCHORS AT DOUBLE SIDE OF SHEARWALL SHEARWALL WHERE OCCURS SOLE PLATE ANCHORAGE PER SHEARWALL SCHEDULE 1/2" MAX. SHEARWALL WHERE OCCURS CONCRETE SLAB PLATE WASHER 0.229"x3"x3"- MIN. @SHEARWALL APPLICABLE NOTE 2@SHEARWALL APPLICABLE NOTE 2 WOOD SHEARWALL SILL PLATE ANCHORAGE 1/2" MAX. 14 SPLICE LENGTH OF REINFORCEMENT REBAR TENSION SPLICE LENGTH (PROVIDED MASONRY COVER, CLEAR BAR SPACING AND TRANSVERSE REINFORCEMENT ARE IN COMPLIANCE WITH ACI 530-13, SECTION 9.3.3.3 ) fy f'm 1500 3 4 5 6 7 8 9 SPLICE LENGTH IN INCHES 19 34 45 54 63 72 81 18 30 45 54 63 72 81 18 26 41 54 63 72 81 18 24 38 54 63 72 81 BAR SIZE (psl)(psl) 2000 2500 3000 60000 CLASS B REBAR TENSION SPLICE LENGTH (PROVIDED CONCRETE COVER, CLEAR BAR SPACING AND TRANSVERSE REINFORCEMENT ARE IN COMPLIANCE WITH ACI 318-19, CHAPTER 25) f'c 25 0 0 P S I NO R M A L WE I G H T CO N C R E T E 30 0 0 P S I NO R M A L WE I G H T CO N C R E T E LOCATION *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS Fy 40 60 40 60 40 60 40 60 3 4 5 6 7 8 9 10 11 SPLICE LENGTH IN INCHES 20 27 34 41 59 68 76 86 95 30 41 51 61 89 101 114 129 143 16 21 26 31 46 52 59 66 73 23 31 39 47 68 78 88 99 110 19 25 31 37 54 62 70 78 87 28 37 46 56 81 93 104 118 131 14 19 24 28 42 47 54 60 67 21 28 36 43 62 71 80 90 100 45 0 0 P S I NO R M A L WE I G H T CO N C R E T E *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS 40 60 40 60 17 22 28 33 49 55 63 70 78 25 33 42 50 73 83 94 105 117 13 17 22 26 37 43 48 54 60 19 26 32 38 56 64 72 81 90 15 Pr o j e c t A d d r e s s : NE W D E T A C H E D A D U 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 01 / 2 2 / 2 0 2 5 1 RE V I S I O N # 1 901 E Myrtle St Unit# 23/14/2025 FOOTING SCHEDULE LEGEND FOUNDATION NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.TOP OF ALL EXTERIOR FOOTING, GRADE BEAM FOOTING, PAD FOOTING, OR FLAG POLE FOOTING TO BE MIN. 6" BELOW FINISH GRADE. 4.FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 5.FOR DOUBLE SHEAR PANEL TYPES SW3, SW4, SW5 USE MIN. 3X6 SILL PLATES U.N.O. DENOTES HOLDOWN PER SCHEDULE DENOTES PAD NUMBER PER SCHEDULE DENOTES SLAB STEP PER ARCH. (VERIFY PRIOR TO CONSTRUCTION) DENOTES FOOTING HOLDOWN SCHEDULE DENOTES DETAIL SHEET NUMBER DENOTES DETAIL NUMBER DENOTES PAD REFER TO DETAIL 10/SD1.0 PAD SIZESYMBOL 2'-0" SQ. x 18" THICK SYMBOL SIMPSON HOLDOWN USP HOLDOWN NOTES -HDU2 X SDX DENOTES SHEAR PANEL LENGTH DENOTES PANEL TYPE, REFER TO SHEARWALL SCHEDULE STEP REINFORCEMENT (3) #4 E.W. X X X X'-X" P1 HD1 DENOTES POST OR TRIMMER AS NOTED #X DENOTES PAD NUMBER IN CALCULATIONS CF1 CONT. W=12", D=18"CONT. (2) #4 TOP & BOTTOM -HDU4HD2 1 BEDROOM#1 KITCHEN LIVINGBEDROOM#2 W.I.C BATH#1 BATH#2 A B D SW1 8'-0" SW2 12'-0" 1 SW 1 8' - 0 " 2 SW 2 8' - 0 " HD2 3 P1 P1 THICK CONVENTIONAL AND UNDERLAYMENT PER DETAIL 1/SD1.0 SLAB w/#4 @ 18" O.C. E.W. 5" ST E P STEP 1 SD1.0 1 SD1.0 1 SD1.0 1 SD1.0 1 SD1.0 3 SD1.0 2 SD1.0 TYP. MP B 6 6 Z 5 SD1.0 9 SD1.0 9 SD1.0 3 SD1.0 9 SD1.0 HD1HD1 HD1 HD1 HD1 HD1 HD1 E MP B 6 6 Z 5 SD1.0 STEP 9 SD1.0 9 SD1.0 9 SD1.0 MPB66 Z 5 SD1.0 MPB66 Z 5 SD1.0 MPB66 Z 5 SD1.0 MPB66 Z 5 SD1.0 P1 P1 P1 P1 1' - 0 " CF1, TYP. 1' - 0 " CF1, TYP. 1'-0" CF1, TYP. 1'-0" CF1, TYP. 1'-0" CF1, TYP. 1'-0" CF1, TYP. HD1 SW 1 12 ' - 0 " HD1 HD1 SW1 2'-4" SW1 2'-4" 3 SD1.0 HD1HD1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 2022 CALIFORNIA BUILDING CODE (1), (3) (4) (2) (1) 800 (PLF) SHEAR ALLOWABLE 220 PANEL TYPE SHEAR 8 d's 10 d's @ 2" O.C. 8 d's @ 2" O.C. @ 3" O.C. 15/32" APA Structural I rated 3/8" APA rated 10 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's@ 6" O.C. 3/8" APA rated rated3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C.8 d's FIELD (COMMON) NAILING PERIODIC SPECIAL INSPECTION IS REQUIRED. (4) (2) (5) (6) USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). SINKER 16d's CONNECTION SILL PLATE @ 4" O.C. @ 6" O.C. @ 3" O.C. @ 2" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. @ 6" O.C. @ 5" O.C. SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. FRAMING CLIPS A35's, LS50's OR LTP4's (5), (6) 2 ROWS STAGG. @ 3" O.C. 1/4"Øx6" SCREWS SDS (8) 260 320 380 410 490 (7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. (8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. (9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. (9) (7) (7) (7) 3/8" APA rated 530 640 (7) (10)FOR DOUBLE SIDED SHEAR PANELS: (10)(10)(10) (10)(10)(10) (10)(10)(10) a. USE HALF THE SPACING OF SILL PLATE ANCHOR BOLTS FOR TYPES SW3, SW4 & SW5. c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND HALF THE SPACING, FOR TYPES SW3, SW4 & SW5. 5/8" Ø 2X A.B. SPC'G @ 24" O.C. @ 16" O.C. @ 8" O.C. @ 8" O.C. @ 6" O.C. 48" 42" 36" 24" 18" SHEAR WALL SCHEDULE (4) (2) (4) (2) (4) (2) (3)STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES SW4 & SW5. SW1 SW2 SW3 SW4 SW5 1 FOUNDATION PLAN SCALE : 1/4" = 1'-0" R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 01/24/2025 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 01/24/2025 01 / 2 2 / 2 0 2 5 1 S-1.0 FO U N D A T I O N P L A N RE V I S I O N # 1 901 E Myrtle St Unit# 23/14/2025 FRAMING NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.USP CONNECTORS CAN BE USED IN LIEU OF SIMPSON STRONG TIE IN THIS PROJECT. CONTACT E.O.R. FOR CONVERSION TABLE OR SUBMIT SHOP DRAWINGS TO E.O.R. FOR REVIEW AND APPROVAL. 4.ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS, UNO. ON PLAN OR DETAIL. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ALL FRAMING LEVELS (3B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 x 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.HEADER AT NON-BEARING WALLS, USE 2x4 FOR OPENINGS UP TO 3'-0" MAX., (2)2x4 FOR OPENINGS UP TO 6'-0" MAX., 4x6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). USE 4x4 FOR OPENINGS LESS THAN 16" AT BEARING WALLS WITHOUT POINT LOADS. 9.WOOD HEADER OR POSTS MADE UP OF 2 OR MORE 2X'S SHALL BE SPIKED TOGETHER PER THE NAILING SCHEDULE. 10.SHEARWALL PANEL TO BE NAILED TO ALL MULTIPLE STUDS RECEIVING HOLDOWNS AND DO NOT BREAK AT PERPENDICULAR WALL LOCATIONS, UNO. FRAMING SCHEDULE DENOTES POST OR TRIMMER AS NOTED LEGEND DENOTES SHEAR PANEL LENGTH DENOTES PANEL TYPE, REFER TO SHEARWALL SCHEDULE DENOTES BEAM NUMBER, REFER TO E.O.R. CALCULATIONS DENOTES DIRECTION OF FRAMING MEMBER PER FRAMING SCHEDULE DENOTES DETAIL SHEET NUMBER DENOTES KEY NOTE NUMBER DENOTES BEARING WALL DENOTES OVER FRAMING DENOTES DETAIL NUMBER DENOTES DROP BEAM OR HEADER PER PLAN DENOTES FLUSH BEAM PER PLAN MARK MEMBER TYPE RR1 2 X 6 ROOF RAFTERS @ 16" O.C. X X X X SDX DENOTES DRAG DIRECTION X X'-X" X X CJ1 2 X 6 CEILING JOISTS @ 16" O.C. DENOTES FRAMING ZONE DIVISION X DENOTES SHEARWALL LINE IN CALCULATIONS 1 BEDROOM#1 KITCHEN LIVINGBEDROOM#2 W.I.C BATH#1 BATH#2 6 4x6 HDR4x6 HDR 4x 6 H D R 4x6 HDR 4x 6 H D R 4x 6 H D R 3 6x6 DR BM 2 6x 6 D R B M 6x 6 6x 6 2 4 R. R . w / E . N . R. R . w / E . N . 2x8 RIDGE BOARD RR 1 RR 1 2x 8 R I D G E B O A R D RR1RR1 R.R. w/E.N.R.R. w/E.N. R.R. w/E.N. 2x 8 R I D G E B O A R D RR1 RR1 4x4 A B D SW1 8'-0"4x 4 4x 4 SW2 12'-0" 4x 4 R.R. w/E.N.R.R. w/E.N. 1 SW 1 8' - 0 " 4x4 4x4 2 SW 2 8' - 0 " 4x4 4x4 3 4x4 CJ1 R.R. w/E.N.R.R. w/E.N. 1A SD2.0 1A SD2.0 1B SD2.0 2B SD2.0 2B SD2.0 2B SD2.0 4 SD2.0 4 SD2.0 4 SD2.0 4 SD2.0 5 SD2.0 5 SD2.0 5 SD2.0 6 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 7 SD2.0 CJ1 CJ 1 9 SD2.0 9 SD2.0 R.R. w/EN 11A SD2.0 7 SD2.0 12 SD2.0 12 SD2.0 8 S-0.20 TYP. 5 SD2.0 8 SD2.0 LO. HI. 15 SD2.0 16 SD2.0 E CA N T . C O L . CA N T . C O L . DB L . C . J . DB L . C . J . C.J. C.J. 1 6x 6 D R B M 1 6x 6 D R B M 1 6x 6 D R B M 6x6 R.R. w/E.N. 12 SD2.0 4 SD2.0 14 SD2.0 R. R . w / E . N . R. R . w / E . N . R.R. w/E.N. 7 SD2.0 6x6 12 SD2.0 6x6 12 SD2.0 6x6 12 SD2.0 4x 1 2 F L B M 1.1 SW1 2'-4" SW1 2'-4" 13B SD2.0 HUCHUC 9 S-0.20 TYP. 6x 6 D R B M 4x6 HDR 4x 4 4x 4 4x6 HDR SW 1 12 ' - 0 " 4x4 4x4 4x4K.P . 17 SD2.0 4x 6 17 SD2.0 5 2x 8 R I D G E B M 10A SD2.0 18 SD2.0 7 SD2.0 1 1 1 1 1 1 1 1 1 4 CANT. C O L . CANT. C O L . CANT. C O L . CANT. C O L . 2022 CALIFORNIA BUILDING CODE (1), (3) (4) (2) (1) 800 (PLF) SHEAR ALLOWABLE 220 PANEL TYPE SHEAR 8 d's 10 d's @ 2" O.C. 8 d's @ 2" O.C. @ 3" O.C. 15/32" APA Structural I rated 3/8" APA rated 10 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's@ 6" O.C. 3/8" APA rated rated3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C.8 d's FIELD (COMMON) NAILING PERIODIC SPECIAL INSPECTION IS REQUIRED. (4) (2) (5) (6) USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). SINKER 16d's CONNECTION SILL PLATE @ 4" O.C. @ 6" O.C. @ 3" O.C. @ 2" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. @ 6" O.C. @ 5" O.C. SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. FRAMING CLIPS A35's, LS50's OR LTP4's (5), (6) 2 ROWS STAGG. @ 3" O.C. 1/4"Øx6" SCREWS SDS (8) 260 320 380 410 490 (7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. (8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. (9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. (9) (7) (7) (7) 3/8" APA rated 530 640 (7) (10)FOR DOUBLE SIDED SHEAR PANELS: (10)(10)(10) (10)(10)(10) (10)(10)(10) a. USE HALF THE SPACING OF SILL PLATE ANCHOR BOLTS FOR TYPES SW3, SW4 & SW5. c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND HALF THE SPACING, FOR TYPES SW3, SW4 & SW5. 5/8" Ø 2X A.B. SPC'G @ 24" O.C. @ 16" O.C. @ 8" O.C. @ 8" O.C. @ 6" O.C. 48" 42" 36" 24" 18" SHEAR WALL SCHEDULE (4) (2) (4) (2) (4) (2) (3)STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES SW4 & SW5. SW1 SW2 SW3 SW4 SW5 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 01/24/2025 Pr o j e c t A d d r e s s : SI N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , C A 9 2 7 0 1 Pr o j e c t N a m e : DE S C R I P T I O N 01/24/2025 01 / 2 2 / 2 0 2 5 1 S-2.0 RO O F F R A M I N G P L A N ROOF FRAMING PLAN SCALE : 1/4" = 1'-0" RE V I S I O N # 1 901 E Myrtle St Unit# 23/14/2025 RE V I S I O N # 1 901 E Myrtle St Unit# 23/14/2025 RE V I S I O N # 1 901 E Myrtle St Unit# 23/14/2025 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 T24.1 TITLE 24 (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 1 901 E Myrtle St Unit# 23/14/2025 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 T24.2 TITLE 24 (CONT.) (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 901 E Myrtle St Unit# 23/14/2025 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 T24.3 TITLE 24 (CONT.) (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 901 E Myrtle St Unit# 23/14/2025 W GG W 5% MIN. 2% MIN. 2% 5% MIN. 5%MI N . 5%MIN . 2% MIN. 2% MIN. 2% 2% 2% 2% 5% MIN. 2% 2% MIN. 2% 5% MIN. 2% MIN. 5%MI N . 5%MI N . 2% 2% PL 56.58' PL 1 0 0 . 0 2 ' PL 64.87' PL 14.28' PL 35.46' PL 42.84' (E) TO CENTER LINE 30 ' - 0 " (E) 2-CAR GARAGE 420 SF SINGLE FAMILY RESIDENCE 1044 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 TO CENTERLINE 10 ' - 0 " (E) TOCENTER LINE 30'-0" (E) PROCH STREET CURB & GUTTER CENTERLINE OF STREET CENTERLINE OF STREET (E) 22 ' - 6 " F.S.D 3' - 0 " F.S.D 3' - 0 " (N) COVER PATIO 206 SF F.S.L (N) DETACHED ADU -UNIT 2 799 SF 901 E MYRTLE ST, SANTA ANA, CA 92701 F.S.D 3' - 0 " F.S.D 3' - 0 " E MYRTLE ST S S T A N D A R D A V E ALLEY A D.01 HIGH POINT FLOW LINE FLOW LINE OVER FLOW OVER FLOW WM-08 FLOW LINE SE-6 SE-6 DISTANCE 5'-0" A D.01 SE-6 SE-6 EXISTING BLOCK WALL EXISTING BLOCK WALL  5% MIN 5% MIN BUILDING DRAINAGE DETAIL NOT TO SCALE A MI N . 8 " FF PAD WEEPSCREEDPER PLAN WIDTH SE-6: PLACE GRAVEL BAG BERM BMP PER CASQA STANDARDS. DETAIL HEREON. WM-8: IMPLEMENT CONCRETE WASHOUT AREA PER CASQA STANDARDS. DETAIL HEREON. EROSION CONTROL CONSTRUCTION NOTES SECTION A -A FINISH GRADE FINISH GRADE TWO (2) BAGS HEIGHT TWO (2) BAGS WIDE A A SE-6: GRAVEL BAG DETAIL NTS GRAVEL BAG BERM SECTION B-B 3 . 0 ' LATH & FLAGGING ON ALL SIDES (WATERPROOFED) VA R I E S 10' MIN. GRAVEL BAG BB 10 MIL. PLASTIC LINING N SCALE: 1"=10' 010'20'20'10'5'15' STREET CENTER LINE FLOW LINE EXISTING SLOPE LEGEND: PROPERTY LINE LANDSCAPE AREA SLOPE SURFACEX% IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 D.01 DRAINAGE PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 901 E Myrtle St Unit# 23/14/2025 W/H AT T I C HP R GD J WP RE F . DW W/ D AT T I C HP R R R R R R R R R R R R WP WP R R R R J GD WP WP WP WP 1. ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. 2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR OR OCCUPANT SENSOR PROVIDED THE OCCUPANT SENSOR IS INITIALLY PROGRAMMED LIKE A VACANCY SENSOR (MANUAL-ON OPERATION). 150(K) 2I 3. LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL THE FOLLOWING: LISTED FOR ZERO CLEARANCE INSULATION, LABELLED THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH A LEAKAGE LESS THAN 2.0CFM AT 75 PASCALS, SEALED WITH A GASKET OR CAULK, ALLOW REPLACEMENT AND MAINTENANCE TO BE READILY ACCESSIBLE FROM BELOW THE CEILING WITHOUT CUTTING HOLES IN THE CEILING, SHALL NOT CONTAIN SCREW BASE SOCKETS, AND SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH JA8. 4. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON AND ONE OF THE FOLLOWING: CONTROLLED BY PHOTOCELL AND MOTION SENSOR, PHOTO CONTROL AND AUTOMATIC SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY MANAGEMENT CONTROL SYSTEM. CBEES 150(K)3 5. NO CONTROLS SHALL BYPASS A DIMMER OR VACANCY SENSOR FUNCTION WHERE THAT DIMMER OR VACANCY SENSOR HAS BEEN INSTALLED TO COMPLY WITH 150.0(K). 1. ALL WORK SHALL BE IN FULL ACCORDANCE WITH ALL APPLICABLE AND REGULATIONS OF GOVERNING AGENCIES AND SHALL COMPLY WITH THE REQUIREMENTS OF THE SERVING POWER AND TELEPHONE COMPANIES. 2. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52. 3. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC ARTICLE 210-70. 4. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8 5. ELECTRICAL SERVICE SIZE: 225 AMPS, MIN. 6. GFCI OUTLETS ARE REQUIRED: FOR ALL KITCHEN RECEPTACLES THAT ARE DESIGNED TO SERVE COUNTERTOP SURFACES, DISHWASHERS, BATHROOMS, IN UNDER-FLOOR SPACES OR BELOW GRADE LEVEL, IN UNFINISHED BASEMENTS, CRAWL SPACE LIGHTING OUTLETS, IN EXTERIOR OUTLETS, WITHIN 6’ OF A LAUNDRY/UTILITY/WET BAR SINK, LAUNDRY AREAS, AND IN ALL GARAGE OUTLETS INCLUDING OUTLETS DEDICATED TO A SINGLE DEVICE OR GARAGE DOOR OPENER. (CEC 210.8). KITCHEN AND LAUNDRY RECEPTACLE SHALL BE BOTH AFCI AND GFCI PROTECTED. 7. OUTDOOR RECEPTACLES SHALL BE LOCATED PER CODE MINIMUM REQUIREMENTS, AND AFCI, GFCI, W.R., AND W.P. WITH A BUBBLE COVER. 8. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO REINFORCING BAR IN CONCRETE FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN. 9. RECEPTACLES AND WALL SWITCHES SHALL BE INSTALLED NOT LESS THAN 15" MEASURED FROM BOTTOM OF IT TO FINISH FLOOR AND LOCATED NO MORE THAN AT 48" MEASURED FROM TOP OF RECEPTACLES AND WALL SWITCHES TO FINISH FLOOR IN VERTICAL DIRECTION, UNLESS OTHERWISE NOTED. ( CBC 1136 ). 10. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24". BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE AND INTERCOM OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY) 11. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION 12. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50% 13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR OBSTRUCTION. 14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO EXCEED 50 DBA (55 DBA WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION 10.26.045 OF THE LOCATION OF MEASUREMENTS TO BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY 15. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE REPLACEMENT 16. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED. 17. PROVIDE RECEPTACLES AT 6' FROM CORNERS, 12' ON CENTER. 18. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM. 19. ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUIT IN KITCHEN, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECT BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI) COMBINATION TYPE (CEC210.12). 20. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 30 MINUTES AND BE MICROWAVE / ULTRASONIC OR PASSIVE INFRA-RED TYPE. 21. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO SLEEPING ROOMS, IN EACH SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE, OR WITHIN 3 FEET OF DOORS TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY BACK-UP. DETECTORS TO BE INTERCONNECTED TO SOUND AT THE SAME TIME. 22. PROVIDE A MINIMUM OF 2 –20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED .(210-52(B)(2) 23. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHW ASHER, CLOTHES WASHER, DRYER, BUILT- IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT 24. ALL 15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPERRESISTANT RECEPTACLES ,ALL 15/20 AMPERE RECEPTACLES IN WET LOCATIONS SHALL HAVE IN-USE (BUBBLE) COVERS INSTALLED. ALL RECEPTACLES IN WET LOCATIONS SHALL ALSO BE LISTED W EATHER-RESISTANT TYPE GFCI. (CEC 406.9(B) (1)) 25. ALL LIGHTS ARE HIGH EFFICACY 26. ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1)) 27. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH EFFICACY. AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. 28. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE A ZERO CLEARANCE INSULATION COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND THE CEILING 29. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT CANDLE (11 LUX). 30. AT LEAST ONE LIGHTING SHALL BE INSTALLED IN THE ATTIC. 31. A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. 210-11(C)3) 32. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR AREA WITHIN 6FT FROM EDGE OF THE SINKS (CEC 210-8) 33. PROVIDE A MINIMUM OF 1 –20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. (210.11(C)(2) 34. IN THE KITCHEN AND DINING AREA, A RECEPTACLE SHALL BE PROVIDED FOR ISLAND COUNTERTOP SPACES WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES OR GREATER. (210-52(C)(2) 35. AT LEAST ONE LIGHT OUTLET, CONTROLLED BY A WALL SWITCH, SHALL BE INSTALLED IN EVERY HABITABLE ROOM, BATH ROOM, HALLWAY, GARAGE AND AT EACH OUT DOOR ENTRANCE. 36. GFCI AT ISLAND CANNOT HAVE MORE THAN 6 INCHES OVERHANG WHERE INSTALLED. 37. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL ON/OFF SWITCH MOTION SENSOR WITHOUT OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION SENSOR AND: A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES ASTRONOMICAL CLOCK C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT ALLOWS LUMINAIRES TO BE ALWAYS ON D. RATED FOR WET LOCATIONS 38. THE MINIMUM SIZE GROUND WIRE SHALL BE #8 CU OR #6 AL. 39. ALL SERVICES SHALL BE GROUNDED WITH A CONCRETE ENCASED ELECTRODE OR A GROUND ROD AND BONDED TO THE COLD WATER PIPE (N) DUAL-GANG ELECT. METER BOX (N) ELECTRICAL SUB-PANEL 200 AMP WITH 225 AMP BUS RATING FOR ADU (PROVIDE MINIMUM 20 FEET UFER GROUND) MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL/ROOF) PHOTOCELL CONTROL / MOTION SENSOR 1 2 3 4 5 7 (N) HEAT PUMP UNIT ON 3'' THIK.CONCRETE PAD6 120-V WATERPROOF RECEPTACLE W/COVER8 EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF)9 10 EXHAUST FAN FOR BATHROOM SHALL BE MIN. 50 CFM AND CONTAIN HUMIDISTAT (EXHAUST THROUGH ROOF) (N) CONSUMER TANK WITH/ HEAT PUMP (N) 22X30 ATTIC ACCESS EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF) EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL IAQ FAN: ( MIN 46 CFM PER T-24 ) PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ BATTERY BACK UPCD 22X30 ATTIC ACCESS AIR HANDLERS HEATPUMP ON PAD 3" MIN. HEATPUMP WATER HEATER L.E.D. RECESSED LIGHT FIXTURE GF C I 110V DUPLEX OUTLET, ARC FAULT CIRCUIT INTERRUPTER (ENTIRE CIRCUIT) AF C I CEILING AIR DIFFUSER 110V DUPLEX OUTLET, GROUND FAULT CIRCUIT INTERRUPT (ENTIRE CIRCUIT) GARBAGE DISPOSAL SWITCH W/ MOTION SENSOR (VACANCY SENSOR) VS 3-WAY SWITCH 3 VANITY WALL LIGHT EXTERIOR WALL SCONCE LIGHT VS DIMMER SWITCH D ELECTRICAL PANEL/METER/INVERTER PER KEYNOTE MEDIA OUTLET P PHOTO CELL M J-BOX (CEILING FAN/LIGHT FIXTURE) DRYER EXHAUST W/P : WEATHER -RESISTANT W/R : WATER PROOF T THERMOSTAT 3 WAY DIMMER SWITCH 3D L.E.D. RECESSED LIGHT FIXTURE (WATER PROOF) SD CDSD CDSD SD 30" 3 5 1010 6 9 G/ A AFCI D AF C I 12 ' ' GF C I AFCI D AF C I AF C I AFCI AF C I P P D D VS OS OS VS GF C I GFCI T T 3D AFCI 36'' CLR. FRONT OF PANEL W/P.W/R GFCI FUTURE 240V -READY USE 3 3 3 AF C I 3 AFCI 4 7 7 D 12 ' ' GF C I 10 FT MIN. 14 ' - 2 " P 7 2 1 P 7 P 7 P 7 P P 77 3D AFCI G/A G/A G/A GFCI 12'' 240V G/A,W/P FUTURE 240V -READY USE 240V GFCI, W/P FUTURE 240V -READY USE 240V G/A,W/P GFCI 18" GFCI 60'' IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING , KITCHEN, DINING PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM CONSTRUCTION DOCUMENTS TECHNOLOGIST TAM VO, CDT, LEED AP SIGNATURE 1 1/23/2025 REVISION #1 A.07 PROPOSED ADU ELECTRICAL PLAN (N ) D E T A C H E D A D U , U N I T 2 90 1 E M Y R T L E S T , SA N T A A N A , C A 9 2 7 0 1 (E ) S I N G L E F A M I L Y R E S I D E N C E 90 1 E M Y R T L E S T , S A N T A A N A , CA 9 2 7 0 1 ELECTRICAL NOTESELECTRICAL PLAN KEYNOTESCEILING/ELECTRICAL PLAN LEGEND 1/4" = 1'-0"1PROPOSED ADU CEILING/LIGHTING & POWER PLAN LIGHTING REQUIREMENTS 901 E Myrtle St Unit# 23/14/2025 Structural Calculations Project No.: Amir Deihimi, 231014 901 E MYRTLE ST, SANTA ANA, CA 92701 901 E Myrtle St Unit# 23/14/2025 January, 18, 2023 Project: 23011 Location: 5463 Wadean PI Oakland, CA 94601, USA Client: N/A TABLE OF CONTENTS 901 E Myrtle St Unit# 23/14/2025 ASCE 7 Hazards Report Address: 901 E Myrtle St Santa Ana, California 92701 Standard:ASCE/SEI 7-16 Latitude:33.741885 Risk Category:II Longitude:-117.856714 Soil Class:D - Default (see Section 11.4.3) Elevation:115.50170286928271 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Dec 26 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https://asce7hazardtool.online/ Page 1 901 E Myrtle St Unit# 23/14/2025 Page 2 901 E Myrtle St Unit# 23/14/2025 Page 3 901 E Myrtle St Unit# 23/14/2025 BUILDING INFORMATION A.General: Number of stories 1 Building risk category II Design Code 2022 CBC Load standard ASCE 7-16 Design Load Combination ASD B.Lateral Loads Data: WIND STANDARD ASCE 7-16(Directional Procedure) Exposure C Wind Speed V 95 Enclosure Enclosed Building Velocity pressure qz 0.00256KzKztKdKeV2 (26.10-1) Velocity pressure exposure coefficient Kz from (Table 26.10-1) Directionality Factor Kd 0.85 (Table 26.6-1) Topographic factor defined Kzt 1 (26.8.2) Gust Effect Factor G 0.85 (26.11) Pressures for MWFRS p qGCp – qi(GCpi)(27.3-1) External pressure coefficient Cp from (Fig. 27.3-1) Internal pressure coefficient (GCpi)0.18 (Table 26.13-1)} SEISMIC STANDARD ASCE 7-16(Equivalent Lateral Force Procedure) Seismic Design Category D (Table 11.6-1) Importance factor Ie 1 (Table 1.5-2) Soil Site Class D-Default (Table 20-3-1) Response Spectral Acc. (0.2 sec) Ss 1.284 Response Spectral Acc. (1.0 sec) S1 0.458 TL (sec)8 Fa 1.2 (Table 11.4-1) Fv 1.842 (Table 11.4-2) Max. Considered earthquake acc. SMS 1.541 (11.4-1) Max. Considered earthquake acc. SM1 .844 (11.4-2) Design spectral acc. At short period SDS 1.02 (11.4-3) Design spectral acc. at 1s period SD1 0.562 (11.4-4) Response modification coefficient R 6.5 (Table 12.2-1) System overstrength coefficient Ω2.5 (Table 12.2-1) Approximate fundamental period parameters Ct = 0.02 x = 0.75 (Table 12.8-2) Building Height (ft)15 Building period T=Ta (sec)0.152 (12.8-7) Base Shear Adjustment Factor 1 Minimum Cs 0.045 (12.8-5 & 12.8-6) Maximum Cs 0.568 (12.8-3 & 12.8-4) Seismic response coefficient Cs 0.158 (12.8-2) Adjusted Cs 0.158 For allowable stress design V = 0.7CsW 0.111W vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 .8 Page 4 901 E Myrtle St Unit# 23/14/2025 Roof Loads (Load_Roof) Clay Tile 10 psf Framing 2.5 psf Sheathing (1/2" CDX)1.5 psf Ceiling 2.5 psf Insulation 1.5 psf Misc.2 psf Total De ad Load 20 psf Liv e Load 20 psf Total Load 40 psf Interior Wall (Wall_In) Insulation 1 psf Drywall 5 psf Studs 1 psf Misc.3 psf Total De ad Load 10 psf Roof Loads_Patio (Load_Roof) Asphalt shingles 2 psf Framing 2.5 psf Sheathing (1/2" CDX)1.5 psf Solar 4 psf Total De ad Load 10 psf Liv e Load 20 psf Total Load 30 psf Exterior Wall (Wall_Ex) 7/8" Stucco 10 psf Insulation 1 psf Drywall 2.5 psf Studs 1 psf Misc.2.5 psf Total De ad Load 17 psf Ceiling Loads (Load_Ceiling) Framing 6 psf Total De ad Load 6 psf Liv e Load 10 psf Total Load 16 psf DESIGN LOADS vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 5 901 E Myrtle St Unit# 23/14/2025 BEDROOM#1 KITCHEN LIVINGBEDROOM#2 W.I.C BATH#1 BATH#2 SHEARWALL LAYOUT 1 Company : Project : SINGLE FAMILY RESIDENCE Job No.: 231014 Plan : Designed : T.M. Checked : P.P. Date : 08/26/2024 Client : N/A 3 A B D 2 3 D1 D2 D3 E D4 Page 6 901 E Myrtle St Unit# 23/14/2025 SECTION D1 – DIRECTION X Building Dimension (ft):B = 41 L = 48.25 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 16.75 Depth = 10 Wind Height = 15 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =48.25/41=1.18, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.46, qh = 16.79 PSF Wall(LW) P = GCplqh = 6.63 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 17.98 18.65 19.18 19.72 20.52 21.19 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Hip W=16.75', L=10', Slope = 18.43° WW Hip W=16.75', L=10', Slope = 18.43° LW -2.27 55.69 27.96 25.47 55.69 -2.27 25.47 27.96 D1X_ROOF = 84.2 = 0.6 x 140.34 PLF MAX TOTAL = 84.2 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 214 / 16.75 = 255.52 Wall_Ex (DL)= 17 x 20 x (10/2) / 16.75 = 101.49 Cs*W = 0.1106 x (255.52 + 101.49)= 39.49 TOTAL SEISMIC LOAD 39.49 = 39.49 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D1X_ROOF 357.01 10 1 39.49 39.49 357.01 39.49 52.39 104.78 52.39 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D1X_ROOF 16.75 10 43.9 183.7 70.5 295.3 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice SECTION D1 – DIRECTION Y Building Dimension (ft):B = 48.25 L = 41 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 10 Depth = 16.75 Wind Height = 11.5 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =41/48.25=0.85, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.5, qh = 16.79 PSF Wall(LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Gable W=10', L=16.75' WW Gable W=10', L=16.75' LW 12.59 15.24 21.66 6.17 15.24 12.59 6.17 21.66 D1Y_ROOF = 48.95 = 0.6 x 81.58 PLF MAX TOTAL = 48.95 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 214 / 10 = 428.00 Wall_Ex (DL)= 17 x 10 x (10/2) / 10 = 85.00 Cs*W = 0.1106 x (428.00 + 85.00)= 56.74 TOTAL SEISMIC LOAD = 56.74 = 56.74 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D1Y_ROOF 513 10 1 56.74 56.74 513 56.74 75.28 150.56 75.28 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D1Y_ROOF 10.75 16.75 24.2 64.9 15.7 42.2 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 7 901 E Myrtle St Unit# 23/14/2025 SECTION D2 – DIRECTION X Building Dimension (ft):B = 41 L = 48.25 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 24.5 Depth = 18.75 Wind Height = 15 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =48.25/41=1.18, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.46, qh = 16.79 PSF Wall(LW) P = GCplqh = 6.63 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 17.98 18.65 19.18 19.72 20.52 21.19 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Hip W=24.5', L=22.25', Slope = 18.43° WW Hip W=24.5', L=22.25', Slope = 18.43° LW -2.27 55.69 27.96 25.47 55.69 -2.27 25.47 27.96 D2X_ROOF = 64.31 = 0.6 x 107.18 PLF MAX TOTAL = 64.31 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 292 / 24.5 = 238.37 Wall_Ex (DL)= 17 x 34 x (10/2) / 24.5 = 117.96 Wall_In (DL)= 10 x 3 x (10/2) / 24.5 = 6.12 Cs*W = 0.1106 x (238.37 + 117.96 + 6.12)= 40.09 TOTAL SEISMIC LOAD 40.09 = 40.09 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D2X_ROOF 362.45 10 1 40.09 40.09 362.45 40.09 53.19 106.37 53.19 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D2X_ROOF 24.5 18.75 34.8 212.8 42 257.3 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice SECTION D2 – DIRECTION Y Building Dimension (ft):B = 48.25 L = 41 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 18.75 Depth = 24.5 Wind Height = 11.5 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =41/48.25=0.85, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.5, qh = 16.79 PSF Wall(LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Gable W=22.25', L=24.5' WW Gable W=22.25', L=24.5' LW 14.94 18.08 25.7 7.32 18.08 14.94 7.32 25.7 D2Y_ROOF = 73.47 = 0.6 x 122.45 PLF MAX TOTAL = 73.47 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 292 / 18.75 = 311.47 Wall_Ex (DL)= 17 x 15.75 x (10/2) / 18.75 = 71.40 Wall_In (DL)= 10 x 6 x (10/2) / 18.75 = 16.00 Cs*W = 0.1106 x (311.47 + 71.40 + 16.00)= 44.11 TOTAL SEISMIC LOAD = 44.11 = 44.11 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D2Y_ROOF 398.87 10 1 44.11 44.11 398.87 44.11 58.53 117.06 58.53 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D2Y_ROOF 18.75 24.5 22.4 105 28.1 131.8 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 8 901 E Myrtle St Unit# 23/14/2025 SECTION D3 – DIRECTION X Building Dimension (ft):B = 41 L = 48.25 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 14.75 Depth = 29.5 Wind Height = 11.5 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =48.25/41=1.18, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.46, qh = 16.79 PSF Wall(LW) P = GCplqh = 6.63 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 17.98 18.65 19.18 19.72 20.52 21.19 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Gable W=15', L=29.5' WW Gable W=15', L=29.5' LW 12.81 14.73 22.03 5.51 14.73 12.81 5.51 22.03 D3X_ROOF = 68.67 = 0.6 x 114.45 PLF MAX TOTAL = 68.67 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 498.5 / 14.75 = 675.93 Wall_Ex (DL)= 17 x 14.75 x (10/2) / 14.75 = 85.00 Wall_In (DL)= 10 x 22 x (10/2) / 14.75 = 74.58 Cs*W = 0.1106 x (675.93 + 85.00 + 74.58)= 92.41 TOTAL SEISMIC LOAD 92.41 = 92.41 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D3X_ROOF 835.51 10 1 92.41 92.41 835.51 92.41 122.61 245.21 122.61 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D3X_ROOF 14.75 29.5 30.7 113 17.2 63.3 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice SECTION D3 – DIRECTION Y Building Dimension (ft):B = 48.25 L = 41 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 29.5 Depth = 14.75 Wind Height = 15 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =41/48.25=0.85, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.5, qh = 16.79 PSF Wall(LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Hip W=29.5', L=15', Slope = 18.43° WW Hip W=29.5', L=15', Slope = 18.43° LW -2.27 55.69 27.96 25.47 55.69 -2.27 25.47 27.96 D3Y_ROOF = 85.72 = 0.6 x 142.86 PLF MAX TOTAL = 85.72 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 20 x 498.5 / 29.5 = 337.97 Wall_Ex (DL)= 17 x 59 x (10/2) / 29.5 = 170.00 Wall_In (DL)= 10 x 14 x (10/2) / 29.5 = 23.73 Cs*W = 0.1106 x (337.97 + 170.00 + 23.73)= 58.81 TOTAL SEISMIC LOAD = 58.81 = 58.81 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D3Y_ROOF 531.69 10 1 58.81 58.81 531.69 58.81 78.02 156.04 78.02 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D3Y_ROOF 29.5 14.75 78 575.4 85.7 632.2 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 9 901 E Myrtle St Unit# 23/14/2025 SECTION D4 – DIRECTION X Building Dimension (ft):B = 41 L = 48.25 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 26.5 Depth = 10 Wind Height = 14.5 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =48.25/41=1.18, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.46, qh = 16.79 PSF Wall(LW) P = GCplqh = 6.63 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 17.98 18.65 19.18 19.72 20.52 21.19 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Hip W=26.5', L=10', Slope = 18.43° WW Hip W=26.5', L=10', Slope = 18.43° LW -2.04 50.13 25.16 22.92 50.13 -2.04 22.92 25.16 D4X_ROOF = 81 = 0.6 x 135 PLF MAX TOTAL = 81 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 10 x 263 / 26.5 = 99.25 Cs*W = 0.1106 x 99.25 = 10.98 TOTAL SEISMIC LOAD 10.98 = 10.98 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D4X_ROOF 99.25 10 1 10.98 10.98 99.25 10.98 14.56 29.13 14.56 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D4X_ROOF 26.5 10 19.3 127.8 107.3 711 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice SECTION D4 – DIRECTION Y Building Dimension (ft):B = 48.25 L = 41 Mean Height = 15 Base Height = 0.5 Section Dimension (ft):Width = 10 Depth = 26.5 Wind Height = 12.5 Base Height = 0.5 Plate Height:ROOF = 10' WIND LOAD: L/B =41/48.25=0.85, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.5, qh = 16.79 PSF Wall(LW) P = GCplqh = 7.14 PLF WIND HEIGHT (FT):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wall P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 ROOF ELEMENT WDir+WDir-OWDir+OWDir- Gable W=10', L=26.5' LW Gable W=10', L=26.5' WW 25.4 20.99 10.28 36.1 20.99 25.4 36.1 10.28 D4Y_ROOF = 81.49 = 0.6 x 135.82 PLF MAX TOTAL = 81.49 PLF SEISMIC LOAD:V = 0.1106W W_ROOF: Load_Roof (DL)= 10 x 263 / 10 = 263.00 Cs*W = 0.1106 x 263.00 = 29.09 TOTAL SEISMIC LOAD = 29.09 = 29.09 PLF Story Wx (PLF)Hx (ft) Wxxhx /sum(Wixhi) Fx (PLF) Sum(Fi)Sum(Wi)Fpx(PLF) Fpx Min Fpx Max Fpx Design D4Y_ROOF 263 10 1 29.09 29.09 263 29.09 38.59 77.19 38.59 DIAPHRAGM DESIGN: Story Width (ft) Depth (ft) Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) D4Y_ROOF 10 26.5 7.3 18.2 15.4 38.4 15/32 Sheathing and Single-Floor Unblocked w/8d COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) (10 ) 16d sinker per top plate splice vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 10 901 E Myrtle St Unit# 23/14/2025 SHEARWALL AND HARDWARE SCHEDULES (De sign Code : 2022 CBC) A. SHEARWALL SCHEDULE Pane l Type She athing Edge Nail Fie ld Nail Se ismic Allowable (plf) Wind Allowable (plf)Sole Plate Nailing She ar Clip M udsill Anchors Ga (k/in)2x Mudsill 3x Mudsill SW1 3/8" Sheathing 8d @ 6 8d @ 12 260 364 16d Nails @ 6 A35 @ 24 5/8 x 10 @48 -13 SW2 3/8" Sheathing 8d @ 4 8d @ 12 380 532 16d Nails @ 4 A35 @ 16 5/8 x 10 @ 42 -19 SW3 3/8" Sheathing 8d @ 3 8d @ 12 490 686 16d Nails @ 3 A35 @ 8 5/8 x 10 @ 36 -25 SW4 3/8" Sheathing 8d @ 2 8d @ 12 640 896 16d Nails @ 2 A35 @ 8 5/8 x 10 @ 24 -39 SW5 15/32" Structural I 10d @ 2 10d @ 12 800 1120 (2) Rows Stagg, 16d Nails @ 3 A35 @ 6 5/8 x 10 @18 -51 SW3D 3/8" Sheathing 8d @ 3 8d @ 12 980 1372 SDS1/4x6 @ 4 (Both Sides)A35 @ 8 -5/8 x 12 @ 22 50 SW4D 3/8" Sheathing 8d @ 2 8d @ 12 1280 1792 SDS1/4x6 @ 3 (Both Sides)A35 @ 8 -5/8 x 12 @ 16 78 SW5D 15/32" Structural I 10d @ 2 10d @ 12 1600 2241 SDS1/4x6 @ 2 (Both Sides)A35 @ 6 -5/8 x 12 @8 102 B. HOLDOWN SCHEDULE Holdown M in. Post Conne ctors Anchor Bolt Allowable (lbs)Displace me nt all da (in)Re marks HDU2 4X4 6-SDS1/4x2 1/2 5/8"3075 0.088 HD1 HDU4 4X4 10-SDS1/4x2 1/2 5/8"4565 0.114 HD2 HDU5 4X4 14-SDS1/4x2 1/2 5/8"5645 0.115 HD3 HDU8 4X6 20-SDS1/4x2 1/2 7/8"7870 0.113 HD4 HDU11 4X8 30-SDS1/4x2 1/2 1"11175 0.137 HD5 HDU14 4X8 36-SDS1/4x2 1/2 1"14375 0.177 HD6 C. HOLDOWN STRAP SCHEDULE Strap M in. Post Conne ctors Allowable (lbs)Displace me nt all da (in)Re marks CS16 2X4 22-10d 1705 0.026 A (2)CS16 2-2X4 22-10d 3410 0.026 B (2)CS14 2-2X4 30-10d 4980 0.031 C CMST14 4X4 80-16d 6490 0.052 D (3)CS14 3-2X4 30-10d 7470 0.031 C* CMST12 4X6 104-16d 9200 0.069 E (2)CMST14 4X8 80-16d 12980 0.052 F (2)CMST12 6X8 104-16d 18400 0.069 G D. PLATE SPLICE STRAP SCHEDULE Straps Alt. Nails pe r top plate splice Allowable Te nsion Loads Re marksTypeGaFasteners Simpson ST22 16 18-16d 10-16d sinker 1420 A Simpson ST6224 16 28-16d 16-16d sinker 2540 B Simpson ST6236 14 40-16d 22-16d sinker 3845 C Simpson MST37 12 42-16d 24-16d sinker 5080 D Simpson MSTC52 16 62-16d 32-16d sinker 5649 E Simpson MST60 10 68-16d 36-16d sinker 6730 F Simpson CMST12x72"12 74-16d 42-16d sinker 9215 G vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 11 901 E Myrtle St Unit# 23/14/2025 OVERTURNING LOAD COMBINATIONS (De sign Code : 2022 CBC) ULIFT DOWN 1. 0.6D - 0.6W 1. D + 0.6W 2. (0.6 - 0.14Sds)D - 0.7ρE 2. D + 0.75(L + Lr + 0.6W) 3. D + 0.75(L + S + 0.6W) 4. (1+0.105Sds)D + 0.75(L + S + 0.7ρE) 5. (1+0.14Sds)D + 0.7ρE vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 12 901 E Myrtle St Unit# 23/14/2025 SW_LINE A 1st Floor Passe d Exterior Wall Drection X Location:(0.00, 0.00) Loads SECTION D3X_ROOF: W=506 LB, E=682 LB (14.75ft) SECTION D2X_ROOF: W=474 LB, E=296 LB (14.75ft) Wall Self-Weight Seismic = 500 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 48.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 123 221 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1272 1767 680 226 0 0 0 1272 1767 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 1986 2555 HDU2/4X4 0.65/0.33 1986 2555 HDU2/4X4 0.65/0.33 1.414 2.400 vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 13 901 E Myrtle St Unit# 23/14/2025 SW_LINE B 1st Floor Passe d Exterior Wall Drection X Location:(0.00, 0.00) Loads SECTION D3X_ROOF: W=506 LB, E=682 LB (14.75ft) SECTION D2X_ROOF & D1X_ROOF: W=1492 LB, E=911 LB (34ft & 11.5ft) Wall Self-Weight Seismic = 366 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 48.00 Total panel Length (ft): 12.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 12.00 10.00 0.83 167 203 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 1020 226 0 0 0 1707 1601 1020 226 0 0 0 1707 1601 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 12.00 10.00 1615 2339 HDU2/4X4 0.53/0.31 1615 2339 HDU2/4X4 0.53/0.31 1.129 2.400 vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 14 901 E Myrtle St Unit# 23/14/2025 SW_LINE D 1st Floor Passe d Exterior Wall Drection X Location:(0.00, 0.00) Loads SECTION D1X_ROOF & D2X_ROOF: W=1071 LB, E=519 LB (16.75ft & 9.5ft) Wall Self-Weight Seismic = 77 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 10.00 Total panel Length (ft): 4.75 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 2.38 7.00 2.94 226 158 260 321 229 SW1 (2) B 2.37 7.00 2.95 226 158 260 321 229 SW1 (2) Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 202 226 0 0 0 2570 1388 202 226 0 0 0 2570 1388 B 201 226 0 0 0 2571 1389 201 226 0 0 0 2571 1389 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 2.38 10.00 2449 2796 HDU2/4X4 0.80/0.37 2449 2796 HDU2/4X4 0.80/0.37 1.908 2.400 B 2.37 10.00 2451 2798 HDU2/4X4 0.80/0.37 2451 2798 HDU2/4X4 0.80/0.37 1.915 2.400 (2) Tension on strap = 1841 < 3300x2 = 6000 Use (2)ST6236 Each Post. See detail on plan for more information. vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 15 901 E Myrtle St Unit# 23/14/2025 SW_LINE E 1st Floor Passe d Exterior Wall Drection X Location:(0.00, 0.00) Loads SECTION D1X_ROOF: W=221 LB, E=107 LB (5.25ft) Wall Self-Weight Seismic = 16 LB Pane l Type : USER DESGIN Total Length (ft): 10.00 Total panel Length (ft): 0.00 ρ = 1.3 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 16 901 E Myrtle St Unit# 23/14/2025 Seismic Calcs Date: 8/26/2024 LINE E : Timber Frames Lateral Load is imported from Wood Frame Analysis (R = 6.5, p = 1.3, ASD Method) ww =0.221 kip Ew =0.156 kip Lateral Load is increased ( Timber Frames ) (R = 1.5, p = 1.3, LRFD Method) W w 0.221 0.6 0.6 Ew x 6.5 0.156 x 6.5 1.5 x 0.7 1.5 x 0.7 Total load on Each Cant. Column 0.37 2 0.74 2 kip kip 0.185 kip 0.37 kip = = 0.37 0.74 W= E = W= E = = = = = Page 17 901 E Myrtle St Unit# 23/14/2025 Wood Column LIC# : KW-06014368, Build:20.23.2.14 Core Structure, inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE E Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: .Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 6x6Analysis Method : 9Overall Column Height ft Load Resistance Factor Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top Free, Bottom Fixed Wood Species Douglas Fir-Larch Wood Grade No.1 Fb +1,200.0 1,200.0 psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf.Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi No Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 9 ft, K = 2.1 Unbraced Length for buckling ABOUT Y-Y Axis = 9 ft, K = 2.1 Brace condition for deflection (buckling) along columns : .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 59.006 lbs * Dead Load Factor BENDING LOADS . . . Lat. Point Load at 9.0 ft creating Mx-x, W = 0.1850, E = 0.370 k .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.5597 Location of max.above base 0.0 ft Applied Axial 0.08293 k Applied Mx -3.330 k-ft Load Combination +1.405D+E Load Combination +0.6946D-E Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 18.347 psi 367.20Allowable Shear psi 0.03331 : 1 Bending Compression Tension LRFD - Format Conversion factor 2.541 2.400 2.700 LRFD - Resistance factor 0.850 0.900 0.800Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0 k Bottom along Y-Y 0.370 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 1.267 in at 9.0 ft above base for load combination :E Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 402.161 psi Other Factors used to calculate allowable stresses . . . for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCLambdaLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +1.20D 0.800 PASS PASS0.0 0.0 0.0 ft0.230 ft0.005898 +1.20D+0.50W 0.800 PASS PASS0.0 0.01041 0.0 ft0.230 ft0.1747 +1.20D-0.50W 0.800 PASS PASS0.0 0.01041 0.0 ft0.230 ft0.1747 +1.20D+W 1.000 PASS PASS0.0 0.01666 0.0 ft0.186 ft0.2796 +1.20D-W 1.000 PASS PASS0.0 0.01666 0.0 ft0.186 ft0.2796 +0.90D+W 1.000 PASS PASS0.0 0.01666 0.0 ft0.186 ft0.2792 +0.90D-W 1.000 PASS PASS0.0 0.01666 0.0 ft0.186 ft0.2792 +1.405D+E 1.000 PASS PASS0.0 0.03331 0.0 ft0.186 ft0.5597 +1.405D-E 1.000 PASS PASS0.0 0.03331 0.0 ft0.186 ft0.5597 +0.6946D+E 1.000 PASS PASS0.0 0.03331 0.0 ft0.186 ft0.5578 +0.6946D-E 1.000 PASS PASS0.0 0.03331 0.0 ft0.186 ft0.5578 . Page 18 901 E Myrtle St Unit# 23/14/2025 Wood Column LIC# : KW-06014368, Build:20.23.2.14 Core Structure, inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE E Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.059 +D+0.60W 0.0590.111 0.999 +D-0.60W 0.059-0.111 -0.999 +D+0.450W 0.0590.083 0.749 +D-0.450W 0.059-0.083 -0.749 +0.60D+0.60W 0.0350.111 0.999 +0.60D-0.60W 0.035-0.111 -0.999 +D+0.70E 0.0590.259 2.331 +D-0.70E 0.059-0.259 -2.331 +D+0.5250E 0.0590.194 1.748 +D-0.5250E 0.059-0.194 -1.748 +0.60D+0.70E 0.0350.259 2.331 +0.60D-0.70E 0.035-0.259 -2.331 W Only 0.185 1.665 -W -0.185 -1.665 E Only 0.370 3.330 E Only * -1.0 -0.370 -3.330 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin0.000 +D+0.60W 0.0000 0.380 9.000ftftinin0.000 +D-0.60W 0.0000 -0.380 9.000ftftinin0.000 +D+0.450W 0.0000 0.285 9.000ftftinin0.000 +D-0.450W 0.0000 -0.285 9.000ftftinin0.000 +0.60D+0.60W 0.0000 0.380 9.000ftftinin0.000 +0.60D-0.60W 0.0000 -0.380 9.000ftftinin0.000 +D+0.70E 0.0000 0.887 9.000ftftinin0.000 +D-0.70E 0.0000 -0.887 9.000ftftinin0.000 +D+0.5250E 0.0000 0.665 9.000ftftinin0.000 +D-0.5250E 0.0000 -0.665 9.000ftftinin0.000 +0.60D+0.70E 0.0000 0.887 9.000ftftinin0.000 +0.60D-0.70E 0.0000 -0.887 9.000ftftinin0.000 W Only 0.0000 0.633 9.000ftftinin0.000 -W 0.0000 -0.633 9.000ftftinin0.000 E Only 0.0000 1.267 9.000ftftinin0.000 E Only * -1.0 0.0000 -1.254 8.940ftftinin0.000 . Page 19 901 E Myrtle St Unit# 23/14/2025 Wood Column LIC# : KW-06014368, Build:20.23.2.14 Core Structure, inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE E Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches Page 20 901 E Myrtle St Unit# 23/14/2025 SW_LINE 1 1st Floor Passe d Exterior Wall Drection Y Location:(1.14, -15.85) Loads SECTION D3Y_ROOF: W=1275 LB, E=875 LB (29.75ft) Wall Self-Weight Seismic = 168 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 15.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 159 163 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1654 1302 680 226 0 0 0 1654 1302 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 1383 1952 HDU2/4X4 0.45/0.25 1383 1952 HDU2/4X4 0.45/0.25 1.026 2.400 vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 21 901 E Myrtle St Unit# 23/14/2025 SW_LINE 2 1st Floor Passe d Exterior Wall Drection Y Location:(0.00, 0.00) Loads SECTION D1Y_ROOF: W=245 LB, E=284 LB (10ft) SECTION D2Y_ROOF: W=367 LB, E=221 LB (10ft) SECTION D3Y_ROOF: W=1275 LB, E=875 LB (29.75ft) Wall Self-Weight Seismic = 249 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 41.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 236 255 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 2448 2038 680 226 0 0 0 2448 2038 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 2339 2907 HDU2/4X4 0.76/0.38 2339 2907 HDU2/4X4 0.76/0.38 1.641 2.400 vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 22 901 E Myrtle St Unit# 23/14/2025 SW_LINE 3 1st Floor Passe d Exterior Wall Drection Y Location:(0.00, 0.00) Loads SECTION D1Y_ROOF: W=245 LB, E=284 LB (10ft) SECTION D2Y_ROOF: W=358 LB, E=215 LB (9.75ft) SECTION D4Y_ROOF: W=357 LB, E=127 LB (8.75ft) Wall Self-Weight Seismic = 496 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 41.00 Total panel Length (ft): 12.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 12.00 13.00 1.08 80 109 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 1326 294 0 0 0 1065 1119 1326 294 0 0 0 1065 1119 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 12.00 13.00 849 1791 HDU2/4X4 0.28/0.23 849 1791 HDU2/4X4 0.28/0.23 0.804 3.120 vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 23 901 E Myrtle St Unit# 23/14/2025 SW_LINE 4 1st Floor Passe d Exterior Wall Drection Y Location:(0.00, 0.00) Loads SECTION D4Y_ROOF: W=357 LB, E=127 LB (8.75ft) Wall Self-Weight Seismic = 50 LB Pane l Type : USER DESGIN Total Length (ft): 24.00 Total panel Length (ft): 0.00 ρ = 1.3 vG23.06.30 : : : : Company Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 24 901 E Myrtle St Unit# 23/14/2025 Seismic Calcs Date: 03/05/2025 LINE 4 : Timber Frames Lateral Load is imported from Wood Frame Analysis (R = 6.5, p = 1.3, ASD Method) 0.357 kip 0.216 kip Lateral Load is increased ( Timber Frames ) (R = 1.5, p = 1.3, LRFD Method) W= =0.357 = 0.6 kip0.6 0.6 E = =0.216 x 6.5 = 1.03 kip1.5 x 0.7 1.5 x 0.7 Total load on Each Cant. Column W=0.60 =0.15 kip4 E =1.03 = 0.26 kip4 ww = Ew = Ww Ew x 6.5 Page 25 901 E Myrtle St Unit# 23/14/2025 Wood Column LIC# : KW-06014368, Build:20.23.2.14 Core Structure, inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE 4 Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: .Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 6x6Analysis Method : 10Overall Column Height ft Load Resistance Factor Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top Free, Bottom Fixed Wood Species Douglas Fir-Larch Wood Grade No.1 Fb +1,200.0 1,200.0 psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf.Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi No Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 10 ft, K = 2.1 Unbraced Length for buckling ABOUT Y-Y Axis = 10 ft, K = 2.1 Brace condition for deflection (buckling) along columns : .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 65.563 lbs * Dead Load Factor BENDING LOADS . . . Lat. Point Load at 10.0 ft creating Mx-x, W = 0.150, E = 0.260 k .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.4381 Location of max.above base 0.0 ft Applied Axial 0.09214 k Applied Mx -2.60 k-ft Load Combination +1.405D+E Load Combination +0.6946D-E Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 12.893 psi 367.20Allowable Shear psi 0.02341 : 1 Bending Compression Tension LRFD - Format Conversion factor 2.541 2.400 2.700 LRFD - Resistance factor 0.850 0.900 0.800Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0 k Bottom along Y-Y 0.260 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 1.221 in at 10.0 ft above base for load combination :E Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 328.844 psi Other Factors used to calculate allowable stresses . . . for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCLambdaLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +1.20D 0.800 PASS PASS0.0 0.0 0.0 ft0.188 ft0.007989 +1.20D+0.50W 0.800 PASS PASS0.0 0.008440 0.0 ft0.188 ft0.1578 +1.20D-0.50W 0.800 PASS PASS0.0 0.008440 0.0 ft0.188 ft0.1578 +1.20D+W 1.000 PASS PASS0.0 0.01350 0.0 ft0.152 ft0.2524 +1.20D-W 1.000 PASS PASS0.0 0.01350 0.0 ft0.152 ft0.2524 +0.90D+W 1.000 PASS PASS0.0 0.01350 0.0 ft0.152 ft0.2519 +0.90D-W 1.000 PASS PASS0.0 0.01350 0.0 ft0.152 ft0.2519 +1.405D+E 1.000 PASS PASS0.0 0.02341 0.0 ft0.152 ft0.4381 +1.405D-E 1.000 PASS PASS0.0 0.02341 0.0 ft0.152 ft0.4381 +0.6946D+E 1.000 PASS PASS0.0 0.02341 0.0 ft0.152 ft0.4360 +0.6946D-E 1.000 PASS PASS0.0 0.02341 0.0 ft0.152 ft0.4360 . Page 26 901 E Myrtle St Unit# 23/14/2025 Wood Column LIC# : KW-06014368, Build:20.23.2.14 Core Structure, inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE 4 Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.066 +D+0.60W 0.0660.090 0.900 +D-0.60W 0.066-0.090 -0.900 +D+0.450W 0.0660.068 0.675 +D-0.450W 0.066-0.068 -0.675 +0.60D+0.60W 0.0390.090 0.900 +0.60D-0.60W 0.039-0.090 -0.900 +D+0.70E 0.0660.182 1.820 +D-0.70E 0.066-0.182 -1.820 +D+0.5250E 0.0660.137 1.365 +D-0.5250E 0.066-0.137 -1.365 +0.60D+0.70E 0.0390.182 1.820 +0.60D-0.70E 0.039-0.182 -1.820 W Only 0.150 1.500 -W -0.150 -1.500 E Only 0.260 2.600 E Only * -1.0 -0.260 -2.600 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000 ftftinin0.000 +D+0.60W 0.0000 0.423 10.000 ftftinin0.000 +D-0.60W 0.0000 -0.423 10.000 ftftinin0.000 +D+0.450W 0.0000 0.317 10.000 ftftinin0.000 +D-0.450W 0.0000 -0.317 10.000 ftftinin0.000 +0.60D+0.60W 0.0000 0.423 10.000 ftftinin0.000 +0.60D-0.60W 0.0000 -0.423 10.000 ftftinin0.000 +D+0.70E 0.0000 0.855 10.000 ftftinin0.000 +D-0.70E 0.0000 -0.855 10.000 ftftinin0.000 +D+0.5250E 0.0000 0.641 10.000 ftftinin0.000 +D-0.5250E 0.0000 -0.641 10.000 ftftinin0.000 +0.60D+0.70E 0.0000 0.855 10.000 ftftinin0.000 +0.60D-0.70E 0.0000 -0.855 10.000 ftftinin0.000 W Only 0.0000 0.705 10.000 ftftinin0.000 -W 0.0000 -0.705 10.000 ftftinin0.000 E Only 0.0000 1.221 10.000 ftftinin0.000 E Only * -1.0 0.0000 -1.209 9.933 ftftinin0.000 . Page 27 901 E Myrtle St Unit# 23/14/2025 Wood Column LIC# : KW-06014368, Build:20.23.2.14 Core Structure, inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CANT. COLUMN LINE 4 Project File: 231014.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches Page 28 901 E Myrtle St Unit# 23/14/2025 LOAD COMBINATIONS (Load Standard: ASCE 7-16) id Load case De ad Sds*De ad Liv e Roof Liv e Snow Wind Se ismic Dire ction Load Dur ation Factor CD 1 D 1 0.9 2 D + L 1 1 1 3 D + Lr 1 1 1.25 4 D + S 1 1 1.15 5 D + 0.75L + 0.75Lr 1 0.75 0.75 1.25 6 D + 0.75L + 0.75S 1 0.75 0.75 1.15 7 D + 0.6W (N)1 0.6 N_S 1.6 8 D + 0.6W (S)1 0.6 S_N 1.6 9 D + 0.6W (E)1 0.6 E_W 1.6 10 D + 0.6W (W)1 0.6 W_E 1.6 11 D + 0.75(0.6W) (N) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 N_S 1.6 12 D + 0.75(0.6W) (S) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 S_N 1.6 13 D + 0.75(0.6W) (E) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 E_W 1.6 14 D + 0.75(0.6W) (W) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 W_E 1.6 15 D + 0.75(0.6W) (N) + 0.75L + 0.75S 1 0.75 0.75 0.45 N_S 1.6 16 D + 0.75(0.6W) (S) + 0.75L + 0.75S 1 0.75 0.75 0.45 S_N 1.6 17 D + 0.75(0.6W) (E) + 0.75L + 0.75S 1 0.75 0.75 0.45 E_W 1.6 18 D + 0.75(0.6W) (W) + 0.75L + 0.75S 1 0.75 0.75 0.45 W_E 1.6 19 0.6D + 0.6W (N)0.6 0.6 N_S 1.6 20 0.6D + 0.6W (S)0.6 0.6 S_N 1.6 21 0.6D + 0.6W (E)0.6 0.6 E_W 1.6 22 0.6D + 0.6W (W)0.6 0.6 W_E 1.6 23 (1.0 + 0.14Sds)D + 0.7ΩE (N)1 0.14 0.7 N_S 1.6 24 (1.0 + 0.14Sds)D + 0.7ΩE (S)1 0.14 0.7 S_N 1.6 25 (1.0 + 0.14Sds)D + 0.7ΩE (E)1 0.14 0.7 E_W 1.6 26 (1.0 + 0.14Sds)D + 0.7ΩE (W)1 0.14 0.7 W_E 1.6 27 (1.0 + 0.105Sds)D + 0.525ΩE (N) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 N_S 1.6 28 (1.0 + 0.105Sds)D + 0.525ΩE (S) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 S_N 1.6 29 (1.0 + 0.105Sds)D + 0.525ΩE (E) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 E_W 1.6 30 (1.0 + 0.105Sds)D + 0.525ΩE (W) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 W_E 1.6 31 (0.6 - 0.14Sds)D + 0.7ΩE (N)0.6 -0.14 0.7 N_S 1.6 32 (0.6 - 0.14Sds)D + 0.7ΩE (S)0.6 -0.14 0.7 S_N 1.6 33 (0.6 - 0.14Sds)D + 0.7ΩE (E)0.6 -0.14 0.7 E_W 1.6 34 (0.6 - 0.14Sds)D + 0.7ΩE (W)0.6 -0.14 0.7 W_E 1.6 vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 29 901 E Myrtle St Unit# 23/14/2025 Be am ID: 1.1 Section type:Douglas Fir-Larch No.2 Section name:2x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : True Applie d Loads: Load_Roof 53.2PLF =2.66 x (20+20)/2 @ 0' to 9' SELF WEIGHT 1.93PLF From 0' to 9' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1.15 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 128 0 120 0 0 0 0 0 248/0 2 128 0 120 0 0 0 0 0 248/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)558 4.5 1060 53 1.25 Shear (lbs)222 0 1238 18 1.25 Live Deflection 0.118 4.5 0.3 39 - Total Deflection 0.245 4.5 0.45 54 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: 1 Section type:Douglas Fir-Larch No.1 Section name:6x6 Fb(+)/Fb(-) (psi): 1350/1350 Fv (psi): 170 E (psi): 1600000 Lu (ft): 7.5 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 225PLF =11.25 x (20+20)/2 @ 0' to 7.5' SELF WEIGHT 7.09PLF From 0' to 7.5' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 448 0 422 0 0 0 0 0 870/0 2 448 0 422 0 0 0 0 0 870/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)1632 3.75 3884 42 1.25 Shear (lbs)758 7.5 4285 18 1.25 Live Deflection 0.066 3.75 0.25 26 - Total Deflection 0.135 3.75 0.375 36 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 30 901 E Myrtle St Unit# 23/14/2025 Be am ID: 2 Section type:Douglas Fir-Larch No.1 Section name:6x6 Fb(+)/Fb(-) (psi): 1350/1350 Fv (psi): 170 E (psi): 1600000 Lu (ft): 6.25 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 140PLF =7 x (20+20)/2 @ 0' to 6.25' SELF WEIGHT 7.09PLF From 0' to 6.25' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 241 0 219 0 0 0 0 0 460/0 2 241 0 219 0 0 0 0 0 460/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)718 3.12 3887 18 1.25 Shear (lbs)390 6.25 4285 9 1.25 Live Deflection 0.020 3.12 0.208 10 - Total Deflection 0.041 3.12 0.312 13 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: 5 Section type:Douglas Fir-Larch No.2 Section name:2x8 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 240PLF =12 x (20+20)/2 @ 0' to 6.25' SELF WEIGHT 2.55PLF From 0' to 6.25' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.2 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 383 0 375 0 0 0 0 0 758/0 2 383 0 375 0 0 0 0 0 758/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)1184 3.12 1478 80 1.25 Shear (lbs)598 0 1631 37 1.25 Live Deflection 0.054 3.12 0.208 26 - Total Deflection 0.109 3.12 0.312 35 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 31 901 E Myrtle St Unit# 23/14/2025 Be am ID: 3 Section type:Douglas Fir-Larch No.1 Section name:6x6 Fb(+)/Fb(-) (psi): 1350/1350 Fv (psi): 170 E (psi): 1600000 Lu (ft): 9.5 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 53.2PLF =2.66 x (20+20)/2 @ 0' to 9.5' POINT supp#2 of Beam 5 @ 4.75ft, (D=383 Lr=375) SELF WEIGHT 7.09PLF From 0' to 9.5' Point Load Location Factors: Ct = 1 Cm = 1 CL = 0.99 CF = 1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 352 0 314 0 0 0 0 0 665/0 2 352 0 314 0 0 0 0 0 665/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)2480 4.75 3880 64 1.25 Shear (lbs)639 9.5 4285 15 1.25 Live Deflection 0.135 4.75 0.317 43 - Total Deflection 0.282 4.75 0.475 59 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: 4 Section type:Douglas Fir-Larch No.2 Section name:4x12 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 180PLF =9 x (20+20)/2 @ 0' to 14.25' Load_Roof 26.6PLF =1.33 x (20+20)/2 @ 0' to 14.25' SELF WEIGHT 9.23PLF From 0' to 14.25' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 802 0 736 0 0 0 0 0 1538/0 2 802 0 736 0 0 0 0 0 1538/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)5478 7.12 7614 72 1.25 Shear (lbs)1331 0 5906 23 1.25 Live Deflection 0.144 7.12 0.475 30 - Total Deflection 0.301 7.12 0.712 42 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 32 901 E Myrtle St Unit# 23/14/2025 Be am ID: 6 Section type:Douglas Fir-Larch No.2 Section name:4x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 5.25 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 53.2PLF =2.66 x (20+20)/2 @ 0' to 5.25' Wall_Ex 68PLF =4 x 17 @ 0' to 5.25' POINT supp#1 of Beam 5 @ 2.5ft, (D=383 Lr=375) SELF WEIGHT 4.51PLF From 0' to 5.25' Point Load Location Factors: Ct = 1 Cm = 1 CL = 0.99 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 461 0 266 0 0 0 0 0 727/0 2 443 0 248 0 0 0 0 0 691/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)1425 2.5 2137 67 1.25 Shear (lbs)666 0 2888 23 1.25 Live Deflection 0.031 2.57 0.175 18 - Total Deflection 0.078 2.57 0.262 30 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 08/26/2024 Client N/A TIC Structure Design 2023 Page 33 901 E Myrtle St Unit# 23/14/2025 Project: Location: 901 E MYRTLE ST, SANTA ANA, CA 92701 page of StruCalc 9.0 StruCalc Version 10.0.1.5 8/21/2024 4:11:39 PM Collar Tie [201 International Building Code(201 NDS)] 1.5 IN x 5.5 IN x 8.0 FT (7 + 1) @ 16 O.C. #2 - Douglas-Fir-Larch - Dry Use 1.5 x 5.5 Solid Sawn Lumber with minimum Ft = 575 Section Adequate By: 178.0% Controlling Factor: Deflection DEFLECTIONS Live Load Dead Load Total Load Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 0.05 0.05 0.11 IN L/1665 in IN L/832 Center -0.03 -0.03 -0.05 IN 2L/1000 in IN 2L/500 Right RAFTER REACTIONS Lower Live Load @ A & B Lower Dead Load @ A & B Lower Total Load @ A & B Collar Tie Tension LOADS 169 169 338 plf plf plf REACTIONS 225 225 450 584 lb lb lb lb RAFTER SUPPORT DATA Bearing Length B 0.48 in RAFTER DATA Span Length Unbraced Length-Bottom Rafter Pitch Collar Tie Location Roof Duration Factor Peak Notch Depth Base Notch Depth 7 7.38 4 2.59 1.25 0.00 0.00 ft ft Interior :12 ft 1 0 ft ft Eave MATERIAL PROPERTIES Bending Stress: Shear Stress: Modulus of Elasticity: Comp. ┴ to Grain: Controlling Moment: 3.434 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: 6.641 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2, 3 Comparisons with required sections: Section Modulus: Area (Shear): Moment of Inertia (deflection): Moment: Shear: Fb = Cd=1.25 CF=1.30 Cr=1.15 Fv = Cd=1.25 E = Fc - ┴ = 337 ft-lb -373 lb 900 180 1600 625 psi psi ksi psi Base Values Fb' = Fv' = E' = Fc - ┴' = 1682 225 1600 625 psi psi ksi psi Adjusted 2.41 2.49 7.48 337 -373 in3 in2 in4 ft-lb lb Req'd 7.56 8.25 20.8 1060 1238 in3 in2 in4 ft-lb lb Provided RAFTER LOADING Uniform Floor Loading Roof Live Load: Roof Dead Load: Non-Snow Roof Loaded Area: Slope Adjusted Spans And Loads Interior Span: Eave Span: Rafter Live Load: Eave Live Load: Rafter Dead Load: Rafter Total Load: Eave Total Load: LL = DL = RLA = L-adj = L-Eave-adj = wL-adj = wL-Eave-adj = wD-adj = wT-adj = wT-Eave-adj = 20 20 0 7.38 1.05 24 24 25 49 49 psf psf sf ft ft plf plf plf plf plf LOADING DIAGRAM 1 ft 7 ft 2.59 ft 14 ft 0.23 ft COLLAR TIE DESIGN 1.5 x 5.5 Solid Sawn Lumber with minimum Ft = 575 Tension Parallel to Grain Collar Tie Location Collar Tie Tension Collar Tie Capacity Nailing Required @ Both Ends 16d Common 16d Sinker 16d Box Ft = Cd=1.25 Cf=0.00 575 2.59 584 8895 4 Nails 4 Nails 5 Nails psi ft lb lb Base Values Ft' = 1078 psi Adjusted 88 Page 34 901 E Myrtle St Unit# 23/14/2025 Weight of Footing Load_Roof Wall_Ex Footing/Pad ID: CF1 Continuous Footing Soil Bearing: SB = 2400 PSF Post with parallel to footing: Bp = 3.5 in Loads: 225.00 PLF = 150 x 1.00' x 1.50' 490PLF =24.5 x (20+20)/2 153PLF =9 x 17 Design Footing: Total Weight: Wtotal = 868 PLF Footing Width Required: Bf = Wtotal / SB = 868/2400 x 12 = 4.34 in USE 12" WIDE X 18" DEEP Continuous Footing with #4 Cont. @ T & B (U.N.O) vG23.06.30 : : : : Com pany Project (N) DETACHED ADU, UNIT 2 Job No.231014 Plan : : : : Designed T.M. Checked P.P. Date 2023-12-26 Client N/A TIC Structure Design 2023 Page 35 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 GENERAL INFORMATION 01 Project Name 901 E Myrtle St - Unit 2 ADU 02 Run Title Title 24 Analysis 03 Project Location 901 E Myrtle St 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92701 07 Software Version EnergyPro 9.3 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)799 19 Glazing Percentage (%)9.46% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 37 37.9 27.7 Proposed Design 36.6 37.1 27.3 0.4 0.8 0.4 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.05 kWdc •PV System resized to 2.05 kWdc (a factor of 2.046) to achieve 'Standard Design PV' PV scaling 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.18 0.89 1.05 7.83 -0.87 -6.94 Space Cooling 1.29 28.35 0.81 24.87 0.48 3.48 IAQ Ventilation 0.45 4.69 0.45 4.69 0 0 Water Heating 2.24 23.55 1.72 18.81 0.52 4.74 Self Utilization/Flexibility Credit 0 0 0 0 Efficiency Compliance Total 4.16 57.48 4.03 56.2 0.13 1.28 Photovoltaics -2.81 -84.48 -2.81 -83.99 Battery 0 0 Flexibility 0 Indoor Lighting 0.94 8.79 0.94 8.79 Appl. & Cooking 6.52 42.15 6.48 41.7 Plug Loads 5.69 57.9 5.69 57.9 Outdoor Lighting 0.21 1.81 0.21 1.81 TOTAL COMPLIANCE 14.71 83.65 14.54 82.41 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 22.52 21.71 0.81 3.6 Net EUI2 8.24 7.43 0.81 9.83 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.05 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Fan Efficacy Watts/CFM •Verified HSPF2 •Verified heat pump rated heating capacity •Duct leakage testing BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 901 E Myrtle St - Unit 2 ADU 799 1 2 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Area Conditioned HVAC System1 799 10 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) North Wall Living Area R-15 Wall 0 Left 310 53.33 90 South Wall Living Area R-15 Wall 180 Right 310 17.25 90 West Wall Living Area R-15 Wall 270 Front 285 25 90 East Wall Living Area R-15 Wall 90 Back 285 17.8 90 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Roof Living Area R-38 + R-19 Roof Attic n/a n/a 799 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Area Attic RoofLiving Area Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading D4-5068 Window North Wall Left 0 1 33.33 0.3 NFRC 0.22 NFRC Bug Screen WA-5040 Window North Wall Left 0 1 20 0.3 NFRC 0.22 NFRC Bug Screen WB-2620 Window South Wall Right 180 1 5 0.3 NFRC 0.22 NFRC Bug Screen WC-3636 Window South Wall Right 180 1 12.25 0.3 NFRC 0.22 NFRC Bug Screen WB-2620 2 Window West Wall Front 270 1 5 0.3 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1-3068 West Wall 20 0.5 D2-2868 East Wall 17.8 0.5 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Living Area 799 150 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofLiving Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. R-38 + R-19 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem PROPH40 T2 RH37530 (40 gal, JA13) Outside Living Area Living Area WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF2 9.5 36000 24000 EER2SEER2 18 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 450 Required Required No Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 1-hers-dist 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 46 0.35 Exhaust No n/a / n/a No Yes 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. 901 E Myrtle St Unit# 23/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:901 E Myrtle St - Unit 2 ADU Calculation Date/Time:2024-08-30T15:30:17+07:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:901 E Myrtle St, Santa Ana - Unit 2.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-08-30   01:32:11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Sang Luu BB Brothers Corporation 08/30/2024 949 South Coast Dr. Costa Mesa, CA 92626 9498365768 Tam Vo 424-P010194919A-000-000-0000000-0000 08/30/2024 01:39 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 901 E Myrtle St Unit# 23/14/2025