Loading...
HomeMy WebLinkAboutCANCELLED - 1622 E Trinidad Way - PlanCS3N-380|385|390|395|400MS 380 W ~ 400 W BLACK FRAME ON BLACK BACKSHEET MONO PERC MODULE MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 400 W Module efficiency up to 19.7%400 W Better shading tolerance Minimizes micro-crack impacts MORE POWER Lower LCOE & BOS cost HiKuBlack Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa* products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. PRODUCT CERTIFIC ATES* MANAGEMENT SYSTEM CERTIFICATES* IEC 61215 / IEC 61730 / CE FSEC (US Florida) UL 61730 / IEC 61701 / IEC 62716 CANADIAN SOLAR (USA), INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. Canadian Solar was recognized as the No. 1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey, and is a leading PV project developer and manufacturer of solar modules, with over 55 GW deployed around the world since 2001.* For detailed information, please refer to the Installation Manual. CANADIAN SOLAR (USA), INC. 3000 Oak Road, Suite 400, Walnut Creek, CA 94597, USA | www.csisolar.com/na | service.ca @csisolar.com 1 st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% 25 Years Years Linear Power Performance Warranty* Industry Leading Product Warranty on Materials and Workmanship* 1622 E Trinidad Way08/29/23 PARTNER SECTION ENGINEERING DRAWING (mm)CS3N-400MS / I-V CURVES products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. professional skills and please carefully read the safety and installation instructions before using our PV modules. MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement 132 [2 X (11 X 6) ] Dimensions Weight Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy Cable 4 mm2 (IEC), 12 AWG (UL) Cable Length (Including Connector) 1650 mm (65.0 in) (-) / 1000 mm (39.4 in) (+)* Connector T4 series or MC4 Per Pallet 30 pieces 720 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A 12 11 10 7 6 5 4 3 2 1 0 V A 1000 W/m2 2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 12 11 10 7 6 5 4 3 2 1 0 065 5 05 540 4 53 035 2 02 510 1 5 06 550 5 54 045 3 03 520 2 51 015 Rear View Mounting Hole 1 1 5 5 1 3 0 0 1000 6- 5 Grounding Hole Mounting Hole A A B B 1 4 Frame Cross Section A - A B - B 25 35 35 35 ELECTRICAL DATA | STC* CS3N 380MS 385MS 390MS 395MS 400MS 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp) 36.4 V 36.6 V 36.8 V 37.0 V 37.2 V Opt. Operating Current (Imp) 10.44 A 10.52 A 10.60 A 10.68 A 10.76 A Open Circuit Voltage (Voc) 43.7 V 43.9 V 44.1 V 44.3 V 44.5 V Short Circuit Current (Isc) 11.26 A 11.32 A 11.38 A 11.44 A 11.50 A 19.2% 19.4% 19.7%18.7% 18.9% Operating Temperature 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 61730 1500V) or TYPE 2 (UL 61730 1000V) or CLASS C (IEC 61730) 20 A Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m 2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3N 380MS 385MS 390MS 395MS 400MS 285 W 34.1 V 8.35 A 41.3 V 9.08 A 289 W 34.3 V 8.42 A 41.5 V 9.13 A 293 W 34.5 V 8.48 A 41.7 V 9.18 A 296 W 34.7 V 8.54 A 41.9 V 9.22 A 300 W 34.9 V 8.60 A 42.1 V 9.27 A Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. CANADIAN SOLAR (USA), INC. July 2021 | All rights reserved | PV Module Datasheet v2.7J25_F30_J3_NA 1622 E Trinidad Way08/29/23 solaredge.com SolarEdge Home Hub Inverter For North America SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) Optimized battery storage with HD-Wave technology Record -breaking 99% weighted efficiency with 200% DC oversizing Small, lightweight, and easy to install Modular design, future ready with optional upgrades to: DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge Home EV Charger Multi-inverter, scalable storage solution With enhanced battery power up to 10kW Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020, per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 12-25 YEAR WARRANTY HO M E B A C K U P 1622 E Trinidad Way08/29/23 SolarEdge Home Hub Inverter For North America SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) Applicable to inverters with part number SEXXXXH-USSNBBXX4 SE11400H – XXXXXBXX5 SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT – AC ON GRID Rated AC Power 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208 W Maximum AC Power Output 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208 W AC Frequency Range (min - nom - max)59.3 – 60 – 60.5(2)Hz Maximum Continuous Output Current @ 240V 16 25 32 42 47.5 A Maximum Continuous Output Current @ 208V 16 24 --48.5 A GFDI Threshold 1 A Total Harmonic Distortion (THD)< 3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if allowed)Yes Typical Nighttime Power Consumption < 2.5 W OUTPUT – AC BACKUP(3) Rated AC Power in Backup Operation(4)3800 6000 7600 10300 10300 W7600*10300* AC L-L Output Voltage Range in Backup 211 – 264 Vac AC L-N Output Voltage Range in Backup 105 – 132 Vac AC Frequency Range in Backup (min - nom - max)55 – 60 – 65 Hz Maximum Continuous Output Current in Backup Operation 16 25 32 43 43 A32*43* GFDI 1 A THD < 5 % OUTPUT – SOLAREDGE HOME EV CHARGER AC Rated AC Power 9600 W AC Output Voltage Range 211 – 264 Vac On-Grid AC Frequency Range (min - nom - max)59.3 – 60 – 60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery)40 Aac INPUT – DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT – DC (PV) Maximum DC Power @ 240V 7600 12000 15200 22000 22800 W15200*22800* Maximum DC Power @ 208V 6600 10000 --20000 W Maximum Input Current(5) @ 240V 10.5 16.5 20 27 31 Adc20*31* Maximum Input Current(5) @ 208V 9 13.5 --27 Adc Max. Input Short Circuit Current 45 Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % 2-pole Disconnection Yes * Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx. (1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x. (2) For other regional settings please contact SolarEdge support. (3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid. (4) Rated AC power in Backup Operation is valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated. (5) A higher current source may be used; the inverter will limit its input current to the values stated. 1622 E Trinidad Way08/29/23 SolarEdge Home Hub Inverter For North America SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) Applicable to inverters with part number SEXXXXH-USSNBBXX4 SE11400H – XXXXXBXX5 SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT – DC (BATTERY) Supported Battery Types SolarEdge Home Battery, LG RESU Prime(6) Number of Batteries per Inverter Up to 3 SolarEdge Home Battery, up to 2 LG RESU Prime Continuous Power(7)7600 10000 W Peak Power(7)7600 10000 W Max Input Current 20 26.5 Adc 2-pole Disconnection Yes SMART ENERGY CAPABILITIES Consumption Metering Built-in(8) Backup & Battery Storage With Backup Interface (purchased separately) for service up to 200A; up to 3 inverters EV Charging Direct connection to SolarEdge Home EV Charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular(9), Wi-Fi (optional), SolarEdge Home Network (optional) Revenue Grade Metering, ANSI C12.20 Built-in(8) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery)Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS AC Output and EV AC Output Conduit Size / AWG Range 1'' maximum / 14-4 AWG DC Input (PV and Battery) Conduit Size / AWG Range 1'' maximum / 14-6 AWG Dimensions with Connection Unit (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(10) in / mm17.7 x 14.6 x 6.8 / 450 x 370 x 174* Weight with Connection Unit 26 / 11.8 26 / 11.8 41.7 / 18.9 44.9 / 20.3 (10) lb / kg41.7 / 18.9* Noise < 25 < 25 < 50 dBA< 50* Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(11)˚F / ˚C Protection Rating NEMA 4 (6) The part numbers SExxxxH-USxMxxxxx only support the SolarEdge Home Battery. The part numbers SExxxxH-USxNxxxxx support both SolarEdge Home Battery and LG RESU Prime batteries. Requires supporting inverter firmware. (7) Discharge power is limited up to the inverter rated AC power for on-grid and backup applications. (8) For consumption metering current transformers should be ordered separately: SECT-SPL-225A-T-20 or SEACT0750-400NA-20 units per box. Revenue grade metering is only for production metering. (9) Information concerning the Data Plan's terms & conditions is available in the following link: SolarEdge Communication Plan Terms and Conditions.) (10) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4 will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (11) Full power up to at least 50°C / 122°F; for power de-rating information refer to the Temperature De-Rating Technical Note for North America. 1622 E Trinidad Way08/29/23 solaredge.com SolarEdge is a global leader in smart energy technology. By leveraging world-class engineering capabilities and with a relentless focus on innovation, SolarEdge creates smart energy solutions that power our lives and drive future progress. SolarEdge developed an intelligent inverter solution that changed the way power is harvested and managed in photovoltaic (PV) systems. The SolarEdge DC optimized inverter maximizes power generation while lowering the cost of energy produced by the PV system. Continuing to advance smart energy, SolarEdge addresses a broad range of energy market segments through its PV, storage, EV charging, UPS, and grid services solutions. SolarEdge @SolarEdgePV @SolarEdgePV SolarEdgePV SolarEdge www.solaredge.com/corporate/contact solaredge.com © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 23, 2023 DS-000189-NAM Subject to change without notice. Cautionary Note Regarding Market Data and Industry Forecasts: This brochure may contain market data and industry forecasts from certain third-party sources. This information is based on industry surveys and the preparer’s expertise in the industry and there can be no assurance that any such market data is accurate or that any such industry forecasts will be achieved. Although we have not independently verified the accuracy of such market data and industry forecasts, we believe that the market data is reliable and that the industry forecasts are reasonable. 1622 E Trinidad Way08/29/23 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents ƒRapid shutdown cables ƒMicro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): ƒ If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected – option 1 ƒIf the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-)BlaRed (+) with rapid shutdown resistor DC+ DC- 1622 E Trinidad Way08/29/23 solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules PO W E R O P T I M I Z E R 2 5 YEAR WARRANTY * Functionality subject to inverter model and firmware version 1622 E Trinidad Way08/29/23 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: November 8, 2022 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 S500B UNIT INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 125 Vdc MPPT Operating Range 8 – 60 12.5 – 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight (including cables) 655 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) For ambient temperatures above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers)25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6)See(6)13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. * 45mm for S500B 1622 E Trinidad Way08/29/23 solaredge.com SolarEdge Home Battery For North America BAT-10K1P Optimized for SolarEdge Home Hub Inverters(1) DC coupled battery featuring superior overall system efficiency, generating more energy to store and use for on-grid and backup power applications Integrates seamlessly with the complete SolarEdge Home ecosystem using SolarEdge Home Network, offering a single source for warranty, support, and training, to streamline logistics & operations Enhanced safety with Rapid Shutdown, SafeDC™ Qualified by the latest and most stringent UL fire safety standard Solar, storage, EV charging, and smart devices all monitored and managed by a single app to an optimized production, consumption, and backup* power Simple plug and play installation, with automatic SetApp-based configuration Flexible installation - wall or floor mount, all indoor or outdoor Wireless communication to the inverter, reducing wiring, labor, and installation BA T T E R I E S 10 YEAR WARRANTY * Backup applications are subject to local regulation and may require additional components and firmware upgrade 1622 E Trinidad Way08/29/23 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: August 14, 2022 DS-000167-NAM. Subject to change without notice. SolarEdge Home Battery For North America BAT-10K1P BAT-10K1PS0B-02 BATTERY SPECIFICATION Usable Energy (100% depth of discharge)9700 Wh Continuous Output Power 5000 W Peak Output Power (for 10 seconds)7500 W Peak Roundtrip Efficiency >94.5 % Warranty(1)10 Years Voltage Range 350-450 Vdc Communication Interfaces Wireless and RS485(2) Batteries per Inverter Up to 3(3) STANDARD COMPLIANCE Certification Cell UL1642 Battery UL1973, UL9540A, UL9540, UN38.3 Emissions FCC Part 15 Class B MECHANICAL SPECIFICATIONS Dimensions (W x H x D)31.1 x 46.4 x 9.84 / 790 x 1179 x 250 in / mm Weight 262 / 119 lb / kg Mounting Floor(4) or wall mount(5) Operating Temperature(6)+14 to +122 / -10 to +50 °F / °C Storage Temperature (more than 3 months)+14 to +86 / -10 to +30 °F / °C Storage Temperature (less than 3 months)-22 to + 140 / -30 to +60 °F / °C Altitude 6562 / 2000 ft / m Enclosure Protection IP55 / NEMA 3R - indoor and outdoor (water and dust protection) Cooling Natural convection Noise (at 1m distance)<25 dBA (1) For warranty details, see the SolarEdge Home Battery Limited Product Warranty. (2) The SolarEdge Home Battery is designed for use with SolarEdge Home Network for wireless communication. The inverter might require a matching SolarEdge Home Network Plug-in (more details below). Using RS485 could reduce the usable energy to 9500Wh. (3) Installations with multiple SolarEdge Home Battery connected to a single inverter require a pair of branch connectors (DC + and DC -) per battery excluding the last battery. The branch connectors should be purchased separately. (4) The floor stand is purchased separately. One floor stand is required per SolarEdge Home Battery. See the Accessories P/N table below. (5) Wall mount installation requires handles that should be purchased separately. See the Accessories P/N table below. (6) Note that operating the SolarEdge Home Batteries at extreme temperatures for extended durations of time may void the SolarEdge Home Battery warranty coverage. Please see the SolarEdge Home Battery Limited Product Warranty for additional details. SolarEdge Home Battery – Accessories (purchased separately) ACCESSORY P/N Floor stand IAC-RBAT-FLRSTD-01 Branch connectors set (includes a pair of DC + and DC - connectors) Required for installations with multiple SolarEdge Home Batteries with a single inverter IAC-RBAT-USYCBL-01 Handles IAC-RBAT-HANDLE-01 SolarEdge Home Network Plug-in ENET-HBNP-01 1622 E Trinidad Way08/29/23 (E)2x STUDS @ 16" O.C. W/ MIN. (2) 16d COMMON TOENAILS TO TOP/BOTTOM PLATE 9' - 0 " M A X . H E I G H T 2x4 BLK'G WHERE REQ'D W/ SIMPSON 'A35' CLIP EA. SIDE (E)SILL PLATE (E)DBL 2x TOP PLATE (N)SOLAREDGE ENERGY BANK (MAX. WT.: 270#) (4)1/4 " LAG SCREWS W/ 11 2" MIN. EMBED 1" M I N . T Y P . (E)WALLS SHALL HAVE 1 2" PLYWOOD, 1 2" DRYWALL OR 7 8" STUCCO 12'-6" MAX. TRIBUTARY WIDTH OF ROOF & FLOOR ABOVE 2x4 BLK'G WHERE REQ'D W/ SIMPSON 'A35' CLIP EA. SIDE9' - 0 " M A X . H E I G H T (E)2x4 STUDS @ 16" O.C., TYP. (4)1 4" LAG SCREWS W/ 11 2" MIN. EMBED (N)SOLAR EDGE ENERGY BANK (MAX. WT.: 270#) (4)1 4" LAG SCREWS W/ 11 2" MIN. EMBED N.T.S. SCALE:TYP. NOTES & SPECS 1N.T.S. SCALE: DETAILS McPHERSON ENGINEERING RYAN JAMES McPHERSON, P.E. JURUPA VALLEY, CA 92509 (909) 560-0066 SE@MCPE.GROUP E.O.R. SCALE: N.T.S PROJECT DESCRIPTION: BATTERY WALL MOUNT SHEET DESCRIPTION: EQUIPMENT WALL MOUNT 2 - 2 This item has been digitally signed and sealed on 10/4/2022 1)WORKING CLEARANCES AROUND BATTERY SYSTEM MINIMUM 3' WORKING CLEARANCES ARE REQUIRED AROUND THE SYSTEM FOR CODE COMPLIANCE 2)IF MORE THAN ONE SYSTEM IS INSTALLED - INDIVIDUAL ESS SYSTEMS SHALL BE SEPERATED FRIN EACH OTHER BY AT LEAST 3' EXCEPT WHERE SMALLER SEPERATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE SCALE FIRE TESTING COMPLYING WITH SECTION 1206.1.5 (CFC 1206.11.2.1) 1622 E Trinidad Way08/29/23 Intertek 3933 US Route 11 Cortland, NY 13045 Telephone: 607-753-7311 www.intertek.com Energy Storage System Test Verification of Conformity Applicant Name & Address Solaredge Technologies Ltd. 1 Hamada Street Herzeliya 4673335 ISRAEL Product(s) Tested Energy Storage System DCD-1PH-US-P4H-F-I, DCD-1PH-US-P4H-F-N, DCD-1PH-US-P6H-F-I, DCD-1PH-US-P6H-F-N, DCD-1PH-US-P3H-F-I, DCD-1PH-US-P2H-F-I, DCD-1PH-US-P3H-F-N, DCD-1PH-US-P2H-F-N. ESS Equipment List Equipment Manufacturer Model Inverter SolarEdge SE3000H-US, SE3800H-US SE6000H-US, SE7600H-US, SE10000H-US, SE11400H-US Storage Connection Unit SolarEdge DCD-1PH-US-P4H-F-I, DCD-1PH-US-P4H-F-N, DCD-1PH-US-P6H-F-I, DCD-1PH-US-P6H-F-N, DCD-1PH-US-P3H-F-I, DCD-1PH-US-P2H-F-I, DCD-1PH-US-P3H-F-N, DCD-1PH-US-P2H-F-N. Backup Interface SolarEdge BI-EUSGN-01, BI-NUSGN-01 Battery Pack SolarEdge BAT-10K1P LG Chem RESU10H type-R, RESU10H Prime RESU16H Prime Brand Name(s) SolarEdge Relevant Standard(s)Energy Storage Systems and Equipment [ANSI/CAN/UL 9540:2016 Ed.1] Verification Issuing Office 3933 US Route 11, Cortland, NY 13045 Verification/Report Number(s) 102311344CRT-001f NRTL Disclaimer, Different for each NRTL – Example: “This Verification is for the exclusive use of NRTL's Client and is provided pursuant to the agreement between NRTL and its Client. NRTL's responsibility and liability are limited to the terms and conditions of the agreement. NRTL assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification. Any use of the NRTL name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by NRTL. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply that the material, product, or service is or has ever been under an NRTL certification program.” Name: Mukund Rana Position: Engineering Team Leader Date: Jan-3rd - 2022 On the basis of the referenced test report(s), the sample(s) of the below product has been found to comply with the relevant standard(s) listed on this verification at the time the tests were carried out. 1622 E Trinidad Way08/29/23 FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out! PROTECT THE ROOF Install a high-strength waterproof attachment without lifting, prying or damaging shingles. FLASH LOC LOC OUT WATER With an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple Seal technology delivers a 100% waterproof connection. Cut Away View HIGH-SPEED INSTALL Simply drive lag bolt and inject sealant into the port 4 to create a permanent pressure seal. Cut Away View FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 3 2 4 1 TESTED TO TAS-100 WIND DRIVEN RAIN TEST AND UL441 RAIN TEST 1622 E Trinidad Way08/29/23 FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 FLASH LOC INSTALLATION GUIDE STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down-slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. PRE-INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4” below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32” pilot hole. Clean roof surface of dirt, debris, snow, and ice. Next, BACKFILL ALL PILOT HOLES WITH SEALANT. NOTE: Space mounts per racking system install specifications. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. NOTE: When installing included rail attachment hardware, torque nut to 30 ft/lbs. USE ONLY UNIRAC APPROVED SEALANTS: Chemlink Duralink 50 (included in kit) or Chemlink M-1 SEALANT GAP 1.75" 1622 E Trinidad Way08/29/23 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DRAWING 4/28/2020 FLASHLOC COMP KIT REVISION DATE: DRAWING TYPE: DESCRIPTION: FL - A 0 1 PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085D FLASHLOC COMP KIT DARK, 20 PACK 67 8 " 312 " 33 4" 214 " 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT FLASHLOC BASE MILL OR DARK SS SERRATED FLANGE NUT 1622 E Trinidad Way08/29/23 SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 1622 E Trinidad Way08/29/23 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONL I S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR Q UE S TI ON S OR C U S TOME R S E R VI C E VI S I T UN I R A C .C OM OR C A LL (5 0 5 ) 2 48 -2 7 0 2PUB2018AUG31 – PRINTED UPDATE 1622 E Trinidad Way08/29/23 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 NOTES SHEET P3 SITE PLAN P4 ROOF PLAN P5 RACKING & FRAMING P6 LINE DIAGRAM & DESIGN TABLES P7 PLACARDS & PLACARD MAP P8 OPTIMIZER MAP P9 JOB HAZARD ANALYSIS SS00 SPECIFICATION PAGES JURISDICTION STAMPS: Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 SYSTEM SIZE: 6,630 DC SYSTEM SIZE 6000 AC CEC POWER OUTPUT: 6193.1 CEC PROPERTY INFORMATION OWNER: Luz Ramos PHONE: 1714-803-7113 EMAIL: luz-er@att.net CONTRACTOR:BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: SANTA ANA (CA) UTILITY: SOUTHERN CALIFORNIA EDISON DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 130 MPH ROOF SURFACE: 2317 SQ.FT. PV SQ FOOTAGE: 363.09 PV COVERAGE: 15.67 % WEIGHT OF EQUIPMENT: 810.73 LBS WEIGHT PER ATTACHMENT: 20.27 LBS DISTRIBUTED WEIGHT: 2.23 PSF NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 39840117 LOT AREA: 6440 LIVING AREA: 1183 MODULE INFORMATION MODULE QTY: MODULE MFG: MODULE TYPE: INVERTER INFORMATION INVERTER QTY: 1 INVERTER MFG: SOLAREDGE INVERTER TYPE: POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 17 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 RAILING INFORMATION RAILING MFG: UNIRAC RAILING TYPE: UNIRAC SM LIGHT MOUNTING INFORMATION MOUNT FLASHING QTY: MOUNT FLASHING MFG: UNIRAC MOUNT FLASHING TYPE: 40 UNIRAC FLASHLOC - MILL 6000H-US (ENERGY HUB) RGM 17 CANADIAN SOLAR CS3N-390MS [Blk] BATTERY INFORMATION BATTERY QTY: BATTERY MFG: BATTERY TYPE: 1 SOLAREDGE ENERGY BANK 10kWh BAT-10K1P EXISTING SOLAR INFORMATION - N/A PROJECT DETAILS ADDITIONAL SCOPE OF WORK MAIN PANEL UPGRADE: (E) 100A/100A TO (N) 225A/200A DERATE MAIN BREAKER: N/A EV CHARGER: N/A ESS: OUTDOORS ON EXTERIOR WALL - (1) SOLAREDGE ENERGY BANK AT 10kWh EACH DISCONNECTS MINIMUM NUMBER OF DISCONNECTS REQUIRED TO TURN OFF POWER SOURCES FEEDING THE HOME 1. UTILITY AC DISCONNECT 2. PV RAPID SHUTDOWN INTEGRATED WITH INVERTER 3. ESS ALL WORK SHALL COMPLY WITH THE MOST CURRENT LOS ANGELES COUNTY FIRE CODE AND ITS SECTIONS. PROJECT SHALL COMPLY WITH THE CURRENT VERSION OF THE LOS ANGELES COUNTY FIRE DEPARTMENT ELECTRICAL POWER SOURCE DISCONNECT PLACARDING SYSTEM. UPSIZE MAIN BREAKER: N/A This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: NOTES SHEET P2 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2022 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND 2022 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). JURISDICTION NOTES ELECTRICAL NOTES CONSTRUCTION NOTES UTILITY NOTES 1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4. THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5. A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6. MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7. ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8. CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. 9. WE WILL MAINTAIN 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. 10. CONDUIT RUNS TO BE DETERMINED IN FIELD CODE REFERENCES · 2022 CALIFORNIA BUILDING CODE · 2022 CALIFORNIA RESIDENTIAL CODE · 2022 CALIFORNIA ELECTRICAL CODE · 2022 CALIFORNIA FIRE CODE · 2022 CALIFORNIA MECHANICAL CODE · 2022 CALIFORNIA GREEN CODE · 2022 CALIFORNIA PLUMBING CODE · 2022 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES GENERAL NOTES JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ROOFTOP CONDUIT SHALL BE A MINIMUM OF 1" ABOVE THE ROOF SURFACE. 5. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 MM INV B SITE PLAN N (N) 225A MAIN SERVICE PANEL P3 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: 1622 TRINIDAD WAY, SANTA ANA, CA 92701 3/32" = 1' JURISDICTION STAMPS: NOTES: (E) DRIVEWAY (E ) P R OP E R T Y L I N E BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 (N) SOLAREDGE 6000H-US (ENERGY HUB) RGM INVERTER (N) BATTERY BANK ARRAY 1 - (N) 11 CANADIAN SOLAR MODULES TILT: 18° AZIMUTH: 269° ARRAY 2 - (N) 6 CANADIAN SOLAR MODULES TILT: 18° AZIMUTH: 89° ROOF ACCESS POINT PER CRC 2022 (R324.6) This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 MM INVB CONDUIT RUN TO BE DETERMINED IN FIELD DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: 3/32" = 1' N ARRAY 1: MODULE QTY: 11 TILT: 18° AZIMUTH: 269° MATERIAL: Comp Asphalt Shingles ARRAY 2: MODULE QTY: 6 TILT: 18° AZIMUTH: 89° MATERIAL: Comp Asphalt Shingles ROOF PLAN P4 ROOF DETAILS:JURISDICTION STAMPS: FIRE CODE PATHWAY BACKUP INTERFACE BACKUP GATEWAYBG BI 3 4" EMT CONDUIT JB JUNCTION BOX LEGEND CALLOUTS: 1 1 4" PVC TRENCH COMBO METER/MAIN MM UTILITY METER MAIN SERVICE PANEL PV METER MSP PV INVERTER SUB PANEL INV SUB AC DISCONNECT AC COMBINER PANELACL AC EV CHARGER BATTERY EV B BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 UM REQUIRED ROOF ACCESS POINT PER CRC 2022 SECTION R324.6 LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS. 3' 6 ' 1'-6" This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 48" FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 2x6 TRUSS @24" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT 2x6 TRUSS TYPICAL WITH PRONGED TRUSS PLATE EITHER SIDE OF ALL JOINTS TYPICAL SOLAR M O D U L E S 14' INVERTER BATERRY METER/MSP WINDOW WINDOW DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE:RACKING & FRAMING DETAILS P5 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAILFRONT VIEW TYP FRAMING DETAIL JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 ELEVATION DETAIL This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 STRING 1: (9x) Canadian Solar CS3N-390MS [Blk] PV MODULES WITH 9 S440 SE POWER OPTIMIZERS 1 1 JUNCTION BOX - NEMA 3R AS REQUIRED 2 3+ - + - + - + - + - + - + - + - + - + - + - + - STRING 2: (8x) Canadian Solar CS3N-390MS [Blk] PV MODULES WITH 8 S440 SE POWER OPTIMIZERS 821 921 (N) INVERTER SOLAREDGE SE6000H-US (ENERGY HUB) RGM DC AC (1) (N) SOLAREDGE ENERGY BANK BAT-10K1P 5.0kW, 9.7kWh 4 (E) GROUNDING ELECTRODE (COPPER) GROUND ROD MAIN (N) 200A (N) 40A M BI-DIRECTIONAL UTILITY METER 1PH/240V SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER MAIN BONDING JUMPER TO UTILITY GRID (OVERHEAD) MAX BREAKER CALC.: 225A X 1.2 - 200A = 70A (N) 225A/200A MAIN SERVICE PANEL 240/120v 1-PH, 3-W POINT OF INTERCONNECTION LOAD SIDE 705.12(B)(3)(2) CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID CONDUCTOR (CU) CONDUIT CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING 2 3/4" EMT 4 & (1)G #8 0.91 15 18.75 40 36.4 90#10 THWN-2, in conduit 1 #10 PV Wire, in open air N/A N/A #6 0.91 15 18.75 40 36.4 90 #8 THWN-2, in conduit 3/4" EMT #8 0.91 32 40 55 50.05 903 & (1)G #10 THWN-2, in conduit 3/4" EMT #8 0.91 21 26 40 36.4 903 & (1)G4 3 DESIGN TEMPERATURES ASHRAE 2% HIGH 30°C 2°C ASHRAE EXTREME LOW INVERTER 1 SPECS SOLAREDGE 6000H-US (Energy Hub)_RGM AC VOLTAGE (V) 240 GROUND MAX OCPD (A) 35 RATED POWER (W) 6000 MAX OUTPUT (A) 25 MAX INPUT (A) 17 MAX INPUT (V) 480 EFFICIENCY (CEC) POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 STRING 2 15A 9 380V 25A 15A 8 380V 25A SYSTEM SUMMARY ARRAY STC POWER 6630W ARRAY PTC POWER 6193.1W MAX AC CURRENT 25A MAX AC POWER 6000W INVERTER 1MODULE SPECS Canadian Solar CS3N-390MS [Blk] PMAX (W) 390 PTC (W) 364.3 ISC (A) 11.38 IMP (A) 10.6 VOC (V) 44.1 VMP (V) 36.8 TEMP. COEFF. OF VOC -0.122 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY MAX OUTPUT(A) MAX DC (V) SOLAREDGE S440 Optimizer 440 15 98.6 15 60 METER NUMBER: 222013-159230 SOLAREDGE INVERTER EQUIPPED WITH RAPID SHUTDOWN PER 690.12 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: LINE DIAGRAM & DESIGN TABLES P6 JURISDICTION STAMPS: EQUIPMENT SPECS NOTES: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION: MULTIPLE SOURCES OF POWER SERVICE BY QUALIFIED PERSONNEL ONLY N1622 TRINIDAD WAY, SANTA ANA, CA 92701 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL INVERTER YOU ARE HERE PLACARD & PLACARD MAP P7 LABELING PLAN PROPERTY MAP NOTES: FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 BATTERY BANK THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY & SOLAR) 6 [690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES 9 [705.12(B)(3)(3)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR [690.14(C)(2)] PLACE ON AC DISCONNECT AC DISCONNECT8 AC PHOTOVOLTAIC POWER SOURCE 7 WARNING INVERTER OUTPUT CONNECTION DON'T RELOCATE THIS OVERCURRENT DEVICE PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) WARNING! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 3 [690.13(B)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 WARNING: PHOTOVOLTAIC POWER SOURCE [690.31(D)(2)] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM4 [690.56(C)(2)] PLACE ON INVERTER AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE5 MAX AC OPERATING CURRENT: AC OPERATING VOLTAGE: MAX VAC240 [690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [690.56(C)] PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE 11 LABEL LOCATED INSIDE PANEL NEXT TO PV BREAKER 25A DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE 2 MAXIMUM SYSTEM VOLTAGE: MAXIMUM CIRCUIT CURRENT: [690.53] AT EACH DC DISCONNECT MEANS (INVERTER 1) MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER (IF INSTALLED) AMPS15 480 VDC 25 AMPS SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 7 3 5 8 3 5 83 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE PRODUCTION METER WHEN APPLICABLE MINIMUM 2-INCH BY 3.5-INCH ENGRAVED ALL-WEATHER PLASTIC F.D. - ELECTRICAL BLDG DISCONNECT #1 OF 3 MINIMUM 2-INCH BY 3.5-INCH ENGRAVED ALL-WEATHER PLASTIC F.D. - ELECTRICAL BLDG DISCONNECT #2 OF 3 EXTERIOR PLACARDS FOR PLACEMENT OUTSIDE ENCLOSURES SMALL SECONDARY PLACARDS FOR PLACEMENT INSIDE ELECTRICAL ENCLOSURES #1 MINIMUM 2-INCH BY 3.5-INCH ENGRAVED ALL-WEATHER PLASTIC F.D. - ELECTRICAL BLDG DISCONNECT #3 OF 3 #2 #3 FIRE DEPARTMENT PLACARDS ENERGY STORAGE SYSTEM DISCONNECT CAUTION THIS PANEL HAS SPLICED FEED- THROUGH CONDUCTORS. LOCATION OF DISCONNECT AT ENERGY STORAGE BACK UP LOAD PANEL. [312.8(A)(3)] PLACE ON MAIN PANEL IF POINT OF INTERCONNECTION IS SUPPLY SIDE CAUTION TRI POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHT PLACE ON MAIN PANEL IF ESS IS IN LINE OF SIGHT ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL PLACE ON MAIN PANEL IF ESS IS ON ADJACENT WALL ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALL PLACE ON MAIN PANEL IF ESS IS ON OPPOSITE WALL ADDITIONAL PLACARDS FOR ENERGY STORAGE SYSTEM PLACE ON ACCESSIBLE ESS DISCONNECT ONLY 1 REQUIRED [705.12(D)(3)] PLACE ON MAIN PANEL IF PV SYSTEM IS ALSO CONNECTED TO PANEL This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/29/23 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P8 SYSTEM SIZE 6630 W DC MODULE TYPE Canadian Solar CS3N-390MS [Blk] MODULE QTY 17 INVERTER TYPE SOLAREDGE 6000H-US (Energy Hub) RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 17 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 51 55 59 63 67 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1622 E Trinidad Way08/29/23 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend.1622 Trinidad Way, Santa Ana, CA 92701 (E) DRIVEWAY(E) ENTRANCE NEAREST MEDICAL FACILITY: NAME: PHONE: ADDRESS: 1 1 4" PVC TRENCH DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION: DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: JOB HAZARD ANALYSIS P9 CREW LEAD: CREW: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1622 E Trinidad Way08/29/23 Date_____________ To Whom it May Concern, I ______________________________ , the owner of the property located at, Property Owner Name ADDRESS:_________________________________________ I Have hired, Better Earth Electric Inc, State Lic #1024460, to install a PV Solar System: __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ Kind Regards , ________________________________ Signature ________________________________ Print Name Better Earth Electric Inc. 1815 E Wilshire Ave. St., 908/909, Santa Ana CA 92705 888-373-9379 SantaAnaPermits@Betterearth.solar 7/16/2023 LUZ RAMOS 1622 E TRINIDAD WAY ROOF MOUNTED PV SYSTEM SIZE OF 6000AC WITH 17 MODULES, OPTIMIZERS, 1 INVERTER ENERGY BANK 5.0KW, 9.7 kWh, MAIN SERVICE PANEL UPGRADE FROM (E)100A/100A TO (N)225A/200A LUZ RAMOS 1622 E Trinidad Way08/29/23 Signature Certificate Reference number: MTEL5-3AOUQ-8XVB8-RC5FK Document completed by all parties on: 16 Jul 2023 00:51:47 UTC Page 1 of 1 Signer Timestamp Signature Luz Ramos Email: luz-er@att.net Recipient Verification: Sent:16 Jul 2023 00:39:33 UTC Viewed:16 Jul 2023 00:39:37 UTC Signed:16 Jul 2023 00:51:47 UTC ✔Email verified 16 Jul 2023 00:39:37 UTC IP address: 107.77.228.156 Signed with PandaDoc PandaDoc is a document workflow and certified eSignature solution trusted by 40,000+ companies worldwide. 1622 E Trinidad Way08/29/23 Digitally sealed by RJM on Date: Job #: 23 - 13044 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group 8/18/23 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Ramos Residence 1622 Trinidad Way Santa Ana, CA 92701 8/18/23 Designed in Accordance with CBC 2022, ASCE 7-16 8/18/2023 12:21 PM 1 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 By: E.C Date: 8/18/23 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On-site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre-engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or descrepancies between current condition of the structure or otherwise as this letter describes before proceding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 8/18/2023 12:21 PM 2 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 By: E.C Date: 8/18/23 Location: 1622 Trinidad Way Santa Ana, CA 92701 Existing Structure Info: Number of Stories = 1 Aroof = 2317 sq. ft. Roof Square Footage A3rd_flr = 0 sq. ft. Third Floor Square Footage (if applicable) A2nd_flr = 0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Lattitude = Longitude = Ss = 1.286 S1 = 0.459 Exposure Category = C Ult. Wind Speed = 130 m.p.h. P.V. Array Info: Model = CS3N-390MS Height of Panel = 76.40 in. Width of Panel = 41.30 in. Area of Panel = 21.9 ft.2 Number of New Panels = 17 Number of Exis. Panels = 0 Total Area of Array = 372.5 ft.2 Spacing of Anchors = 4.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 7-27 deg 33.749640 -117.846518 Project Info 8/18/2023 12:21 PM 3 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 By: E.C Date: 8/18/23 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x6 Trusses Misc = 1.0 p.s.f. DLr1 = 8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f. Drywall and framing DLr2 = 10.0 p.s.f. Total Existing Roof Dead Load LLr = 20.0 p.s.f. Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels = 2.8 p.s.f. weight of panels including rack system DLr1_proposed = 10.8 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 12.8 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) = 64.9 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) = 58.5 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - Wex = -9.90% TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! Wex 8/18/2023 12:21 PM 4 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 By: E.C Date: 8/18/23 Seismic Design Parameters Risk Category = 2 Per Table 1-5-1 R = 6.5 Response Modification Factor (Table 12-2.1) Site Class = D Per 11.4.2 Ie = 1 Seismic Importance Factor (Table 1.5-2) Ss = 1.29 Short Period P.G.A. S1 = 0.46 1-Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa = 1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv = 1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa = 1.54 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv = 0.78 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) = 1.03 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) = 0.52 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 15 ft Ct = 0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T = 0.15 sec Approximate Fundamental Period TL = 8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.79 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie = 0.05 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R = 0.04 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 ≥ 0.6g CS = 0.16 Design Seismic Coefficient Check Additional Base Shear Wexisting = 23.2 kips Weight of Existing Structure Wpanels = 1.0 kips Weight of Proposed Panels Vexisting = Cs Wexisting = 3.7 kips Roof Level Shear of Existing Structure Vpanels = Cs Wpanels = 0.2 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn) x = 4.44% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 8/18/2023 12:21 PM 5 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 By: E.C Date: 8/18/23 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult = 130 mph Kzt = 1.00 (sec 26.8.2) h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd = 0.85 (sec 26.6) Roof θ = 7-27 deg Ke = 1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V 2 qh = 31.26 (eq. 26.10-1) GPp = -2 uplift γE = 1.5 (sec 29.4.4) γa = 0.76 (fig 29.4-8) γE = 1.5 FIG 29.4-7)γc = 0.98 (fig 29.4-7) hpt = 0 γa = 0.76 (fig 29.4-8)γp = 0.9 (fig 29.4-7)ω = 0.00 deg (panel tilt) GPp = -2 uplift GCrm = 1.4 uplift p = qh (GPp) γE γa (eq 29.4-7)p = qh (GCrn) γE γC γp (eq 29.4-6) p = -71.1 p.s.f.p = 58.0 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL = 2.8 p.s.f.dead load of panel (inlcuding rack system) W = 71.1 p.s.f.wind load normal to face of panel Arealag = 12.7 sq. ft.area tributary to each anchor SPanc = 4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) = 522.0 lbs total uplift on anchor Material = DFL lumber anchor material Dialag = 5/16 in. diameter of screw Penlag = 2.5 in. min. penetration to existing framing Wlag = 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews = 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor Puplift Pallow Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) = 0.61 < 1.00 Anchor is OK! 8/18/2023 12:21 PM 6 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 By: E.C Date: 8/18/23 Gravity Loads: DEMAND DECREASED BY 9.9% = OK! Lateral Loads: DEMAND INCREASED BY 4.44% < 10% = OK! Anchorage: DEMAND OF 522.LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 8/18/2023 12:21 PM 7 of 7 ©McPherson Engineering 1622 E Trinidad Way08/29/23 Rev: 8/29/19 S OL-01 C BC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: Th e licensed contractor of record sh all complete all sections, answer the ten q uestions and sign the certification section below. A copy of th is form sh all be attached to each of TW O sets of plans , of minimum 11 ” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. W ill th e PV system layou t provid e the required th ree -foot wide clear access path way s per S ection 605.1 1 of th e C alifornia Fire C od e, and is th is sh own on th e roof plan? 2. W ill th e PV system be installed on a roof having only one roofing layer with no overlays? 3. W ill th e PV array be flu sh mou nted to th e existing roof so th at the plane of th e mod ules (panels) are parallel to th e plane of th e roof? 4. W ill th e PV system weig h maximum 4 pounds per square feet or less? 5. W ill th e PV system be installed wh ere the mod ules do not overh ang any roof ed g es (such as eaves, gabled end s, ridg es and hips)? 6. W ill th e PV system be installed with a space of 2” minimum to 10” maximum between th e u nderside of mod ule s and the surface of the roof? 7. W ill th e PV system be installed withou t u sing any ballast system or counter-weight system? 8. W ill th e anch ors be installed with a maximum horizontal anch or spacing of 6 feet and is this maximum h orizontal spacing shown on the plans? 9. W ill th e minimum 5/1 6” lag screws be installed with a minimum of 2 -1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL th e stru ctu ral pages of the plans stamped and signed by a C alifornia licensed professional eng ineer? (inclu ding project specific site plan, PV layou t, anchorage spacing , anchorag e details and manufactu rer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: S ignature: Ph one Number: Date: Email Ad d ress: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST BETTER EARTH ELE C TRIC INC 1024460 VIC TORIA RUIZ 323-398-9324 VIC TORIA.R@BETTEREARTH.S OLAR 8/22/2023 1622 TRINIDAD WAY 1622 E Trinidad W ay08/29/23 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 NOTES SHEET P3 SITE PLAN P4 ROOF PLAN P5 RACKING & FRAMING P6 LINE DIAGRAM & DESIGN TABLES P7 PLACARDS & PLACARD MAP P8 OPTIMIZER MAP P9 JOB HAZARD ANALYSIS SS00 SPECIFICATION PAGES JURISDICTION STAMPS:Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 SYSTEM SIZE: 6,630 DC SYSTEM SIZE 6000 AC CEC POWER OUTPUT: 6193.1 CEC PROPERTY INFORMATION OWNER: Luz Ramos PHONE: 1714-803-7113 EMAIL: luz-er@att.net CONTRACTOR:BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: SANTA ANA (CA) UTILITY: SOUTHERN CALIFORNIA EDISON DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 130 MPH ROOF SURFACE: 2317 SQ.FT. PV SQ FOOTAGE: 363.09 PV COVERAGE: 15.67 % WEIGHT OF EQUIPMENT: 810.73 LBS WEIGHT PER ATTACHMENT: 20.27 LBS DISTRIBUTED WEIGHT: 2.23 PSF NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 39840117 LOT AREA: 6440 LIVING AREA: 1183 MODULE INFORMATION MODULE QTY: MODULE MFG: MODULE TYPE: INVERTER INFORMATION INVERTER QTY: 1 INVERTER MFG: SOLAREDGE INVERTER TYPE: POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 17 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 RAILING INFORMATION RAILING MFG: UNIRAC RAILING TYPE: UNIRAC SM LIGHT MOUNTING INFORMATION MOUNT FLASHING QTY: MOUNT FLASHING MFG: UNIRAC MOUNT FLASHING TYPE: 40 UNIRAC FLASHLOC - MILL 6000H-US (ENERGY HUB) RGM 17 CANADIAN SOLAR CS3N-390MS [Blk] BATTERY INFORMATION BATTERY QTY: BATTERY MFG: BATTERY TYPE: 1 SOLAREDGE ENERGY BANK 10kWh BAT-10K1P EXISTING SOLAR INFORMATION - N/A PROJECT DETAILS ADDITIONAL SCOPE OF WORK MAIN PANEL UPGRADE: (E) 100A/100A TO (N) 225A/200A DERATE MAIN BREAKER: N/A EV CHARGER: N/A ESS: OUTDOORS ON EXTERIOR WALL - (1) SOLAREDGE ENERGY BANK AT 10kWh EACH DISCONNECTS MINIMUM NUMBER OF DISCONNECTS REQUIRED TO TURN OFF POWER SOURCES FEEDING THE HOME 1. UTILITY AC DISCONNECT 2. PV RAPID SHUTDOWN INTEGRATED WITH INVERTER 3. ESS ALL WORK SHALL COMPLY WITH THE MOST CURRENT LOS ANGELES COUNTY FIRE CODE AND ITS SECTIONS. PROJECT SHALL COMPLY WITH THE CURRENT VERSION OF THE LOS ANGELES COUNTY FIRE DEPARTMENT ELECTRICAL POWER SOURCE DISCONNECT PLACARDING SYSTEM. UPSIZE MAIN BREAKER: N/A This item has been digitally signed and sealed on Aug 18, 2023 Bldg# 101116306 Elec# 20180672 Issued 08/29/23 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 1622 E Trinidad Way 08/30/23 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: NOTES SHEET P2 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2022 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND 2022 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). JURISDICTION NOTES ELECTRICAL NOTES CONSTRUCTION NOTES UTILITY NOTES 1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4. THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5. A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6. MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7. ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8. CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. 9. WE WILL MAINTAIN 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. 10. CONDUIT RUNS TO BE DETERMINED IN FIELD CODE REFERENCES · 2022 CALIFORNIA BUILDING CODE · 2022 CALIFORNIA RESIDENTIAL CODE · 2022 CALIFORNIA ELECTRICAL CODE · 2022 CALIFORNIA FIRE CODE · 2022 CALIFORNIA MECHANICAL CODE · 2022 CALIFORNIA GREEN CODE · 2022 CALIFORNIA PLUMBING CODE · 2022 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES GENERAL NOTES JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ROOFTOP CONDUIT SHALL BE A MINIMUM OF 1" ABOVE THE ROOF SURFACE. 5. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/30/23 MM INV B SITE PLAN N (N) 225A MAIN SERVICE PANEL P3 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: 1622 TRINIDAD WAY, SANTA ANA, CA 92701 3/32" = 1' JURISDICTION STAMPS: NOTES: (E) DRIVEWAY (E ) P R OP E R T Y L I N E BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 (N) SOLAREDGE 6000H-US (ENERGY HUB) RGM INVERTER (N) BATTERY BANK ARRAY 1 - (N) 11 CANADIAN SOLAR MODULES TILT: 18° AZIMUTH: 269° ARRAY 2 - (N) 6 CANADIAN SOLAR MODULES TILT: 18° AZIMUTH: 89° ROOF ACCESS POINT PER CRC 2022 (R324.6) This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/30/23 MM INVB CONDUIT RUN TO BE DETERMINED IN FIELD DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: 3/32" = 1' N ARRAY 1: MODULE QTY: 11 TILT: 18° AZIMUTH: 269° MATERIAL: Comp Asphalt Shingles ARRAY 2: MODULE QTY: 6 TILT: 18° AZIMUTH: 89° MATERIAL: Comp Asphalt Shingles ROOF PLAN P4 ROOF DETAILS:JURISDICTION STAMPS: FIRE CODE PATHWAY BACKUP INTERFACE BACKUP GATEWAYBG BI 3 4" EMT CONDUIT JB JUNCTION BOX LEGEND CALLOUTS: 1 1 4" PVC TRENCH COMBO METER/MAIN MM UTILITY METER MAIN SERVICE PANEL PV METER MSP PV INVERTER SUB PANEL INV SUB AC DISCONNECT AC COMBINER PANELACL AC EV CHARGER BATTERY EV B BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 UM REQUIRED ROOF ACCESS POINT PER CRC 2022 SECTION R324.6 LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS. 3' 6 ' 1'-6" This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/30/23 48" FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 2x6 TRUSS @24" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT 2x6 TRUSS TYPICAL WITH PRONGED TRUSS PLATE EITHER SIDE OF ALL JOINTS TYPICAL SOLAR M O D U L E S 14' INVERTER BATERRY METER/MSP WINDOW WINDOW DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE:RACKING & FRAMING DETAILS P5 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAILFRONT VIEW TYP FRAMING DETAIL JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 ELEVATION DETAIL This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/30/23 STRING 1: (9x) Canadian Solar CS3N-390MS [Blk] PV MODULES WITH 9 S440 SE POWER OPTIMIZERS 1 1 JUNCTION BOX - NEMA 3R AS REQUIRED 2 3+ - + - + - + - + - + - + - + - + - + - + - + - STRING 2: (8x) Canadian Solar CS3N-390MS [Blk] PV MODULES WITH 8 S440 SE POWER OPTIMIZERS 821 921 (N) INVERTER SOLAREDGE SE6000H-US (ENERGY HUB) RGM DC AC (1) (N) SOLAREDGE ENERGY BANK BAT-10K1P 5.0kW, 9.7kWh 4 (E) GROUNDING ELECTRODE (COPPER) GROUND ROD MAIN (N) 200A (N) 40A M BI-DIRECTIONAL UTILITY METER 1PH/240V SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER MAIN BONDING JUMPER TO UTILITY GRID (OVERHEAD) MAX BREAKER CALC.: 225A X 1.2 - 200A = 70A (N) 225A/200A MAIN SERVICE PANEL 240/120v 1-PH, 3-W POINT OF INTERCONNECTION LOAD SIDE 705.12(B)(3)(2) CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID CONDUCTOR (CU) CONDUIT CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING 2 3/4" EMT 4 & (1)G #8 0.91 15 18.75 40 36.4 90#10 THWN-2, in conduit 1 #10 PV Wire, in open air N/A N/A #6 0.91 15 18.75 40 36.4 90 #8 THWN-2, in conduit 3/4" EMT #8 0.91 32 40 55 50.05 903 & (1)G #10 THWN-2, in conduit 3/4" EMT #8 0.91 21 26 40 36.4 903 & (1)G4 3 DESIGN TEMPERATURES ASHRAE 2% HIGH 30°C 2°C ASHRAE EXTREME LOW INVERTER 1 SPECS SOLAREDGE 6000H-US (Energy Hub)_RGM AC VOLTAGE (V) 240 GROUND MAX OCPD (A) 35 RATED POWER (W) 6000 MAX OUTPUT (A) 25 MAX INPUT (A) 17 MAX INPUT (V) 480 EFFICIENCY (CEC) POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 STRING 2 15A 9 380V 25A 15A 8 380V 25A SYSTEM SUMMARY ARRAY STC POWER 6630W ARRAY PTC POWER 6193.1W MAX AC CURRENT 25A MAX AC POWER 6000W INVERTER 1MODULE SPECS Canadian Solar CS3N-390MS [Blk] PMAX (W) 390 PTC (W) 364.3 ISC (A) 11.38 IMP (A) 10.6 VOC (V) 44.1 VMP (V) 36.8 TEMP. COEFF. OF VOC -0.122 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY MAX OUTPUT(A) MAX DC (V) SOLAREDGE S440 Optimizer 440 15 98.6 15 60 METER NUMBER: 222013-159230 SOLAREDGE INVERTER EQUIPPED WITH RAPID SHUTDOWN PER 690.12 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: LINE DIAGRAM & DESIGN TABLES P6 JURISDICTION STAMPS: EQUIPMENT SPECS NOTES: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/30/23 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION: MULTIPLE SOURCES OF POWER SERVICE BY QUALIFIED PERSONNEL ONLY N1622 TRINIDAD WAY, SANTA ANA, CA 92701 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL INVERTER YOU ARE HERE PLACARD & PLACARD MAP P7 LABELING PLAN PROPERTY MAP NOTES: FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS JURISDICTION STAMPS: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 BATTERY BANK THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY & SOLAR) 6 [690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES 9 [705.12(B)(3)(3)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR [690.14(C)(2)] PLACE ON AC DISCONNECT AC DISCONNECT8 AC PHOTOVOLTAIC POWER SOURCE 7 WARNING INVERTER OUTPUT CONNECTION DON'T RELOCATE THIS OVERCURRENT DEVICE PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) WARNING! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 3 [690.13(B)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 WARNING: PHOTOVOLTAIC POWER SOURCE [690.31(D)(2)] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM4 [690.56(C)(2)] PLACE ON INVERTER AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE5 MAX AC OPERATING CURRENT: AC OPERATING VOLTAGE: MAX VAC240 [690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [690.56(C)] PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE 11 LABEL LOCATED INSIDE PANEL NEXT TO PV BREAKER 25A DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE 2 MAXIMUM SYSTEM VOLTAGE: MAXIMUM CIRCUIT CURRENT: [690.53] AT EACH DC DISCONNECT MEANS (INVERTER 1) MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER (IF INSTALLED) AMPS15 480 VDC 25 AMPS SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 7 3 5 8 3 5 83 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE PRODUCTION METER WHEN APPLICABLE MINIMUM 2-INCH BY 3.5-INCH ENGRAVED ALL-WEATHER PLASTIC F.D. - ELECTRICAL BLDG DISCONNECT #1 OF 3 MINIMUM 2-INCH BY 3.5-INCH ENGRAVED ALL-WEATHER PLASTIC F.D. - ELECTRICAL BLDG DISCONNECT #2 OF 3 EXTERIOR PLACARDS FOR PLACEMENT OUTSIDE ENCLOSURES SMALL SECONDARY PLACARDS FOR PLACEMENT INSIDE ELECTRICAL ENCLOSURES #1 MINIMUM 2-INCH BY 3.5-INCH ENGRAVED ALL-WEATHER PLASTIC F.D. - ELECTRICAL BLDG DISCONNECT #3 OF 3 #2 #3 FIRE DEPARTMENT PLACARDS ENERGY STORAGE SYSTEM DISCONNECT CAUTION THIS PANEL HAS SPLICED FEED- THROUGH CONDUCTORS. LOCATION OF DISCONNECT AT ENERGY STORAGE BACK UP LOAD PANEL. [312.8(A)(3)] PLACE ON MAIN PANEL IF POINT OF INTERCONNECTION IS SUPPLY SIDE CAUTION TRI POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHT PLACE ON MAIN PANEL IF ESS IS IN LINE OF SIGHT ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL PLACE ON MAIN PANEL IF ESS IS ON ADJACENT WALL ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALL PLACE ON MAIN PANEL IF ESS IS ON OPPOSITE WALL ADDITIONAL PLACARDS FOR ENERGY STORAGE SYSTEM PLACE ON ACCESSIBLE ESS DISCONNECT ONLY 1 REQUIRED [705.12(D)(3)] PLACE ON MAIN PANEL IF PV SYSTEM IS ALSO CONNECTED TO PANEL This item has been digitally signed and sealed on Aug 18, 2023 1622 E Trinidad Way08/30/23 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION:DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P8 SYSTEM SIZE 6630 W DC MODULE TYPE Canadian Solar CS3N-390MS [Blk] MODULE QTY 17 INVERTER TYPE SOLAREDGE 6000H-US (Energy Hub) RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 17 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 51 55 59 63 67 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1622 E Trinidad Way08/30/23 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend.1622 Trinidad Way, Santa Ana, CA 92701 (E) DRIVEWAY(E) ENTRANCE NEAREST MEDICAL FACILITY: NAME: PHONE: ADDRESS: 1 1 4" PVC TRENCH DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 6630 DC / 6000 AC Luz Ramos 1622 Trinidad Way, Santa Ana, CA 92701 APN: 39840117 8/16/2023DATE: TIME: 10:37 am REVISION: DATE:DESCRIPTION: DRAWING TITLE: DRAWING PAGE: SCALE: DESIGNER SIGNATURE: JOB HAZARD ANALYSIS P9 CREW LEAD: CREW: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1622 E Trinidad Way08/30/23 CS3N-380|385|390|395|400MS 380 W ~ 400 W BLACK FRAME ON BLACK BACKSHEET MONO PERC MODULE MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 400 W Module efficiency up to 19.7%400 W Better shading tolerance Minimizes micro-crack impacts MORE POWER Lower LCOE & BOS cost HiKuBlack Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa* products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. PRODUCT CERTIFIC ATES* MANAGEMENT SYSTEM CERTIFICATES* IEC 61215 / IEC 61730 / CE FSEC (US Florida) UL 61730 / IEC 61701 / IEC 62716 CANADIAN SOLAR (USA), INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. Canadian Solar was recognized as the No. 1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey, and is a leading PV project developer and manufacturer of solar modules, with over 55 GW deployed around the world since 2001.* For detailed information, please refer to the Installation Manual. CANADIAN SOLAR (USA), INC. 3000 Oak Road, Suite 400, Walnut Creek, CA 94597, USA | www.csisolar.com/na | service.ca @csisolar.com 1 st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% 25 Years Years Linear Power Performance Warranty* Industry Leading Product Warranty on Materials and Workmanship* 1622 E Trinidad Way08/30/23 PARTNER SECTION ENGINEERING DRAWING (mm)CS3N-400MS / I-V CURVES products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. professional skills and please carefully read the safety and installation instructions before using our PV modules. MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement 132 [2 X (11 X 6) ] Dimensions Weight Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy Cable 4 mm2 (IEC), 12 AWG (UL) Cable Length (Including Connector) 1650 mm (65.0 in) (-) / 1000 mm (39.4 in) (+)* Connector T4 series or MC4 Per Pallet 30 pieces 720 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A 12 11 10 7 6 5 4 3 2 1 0 V A 1000 W/m2 2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 12 11 10 7 6 5 4 3 2 1 0 065 5 05 540 4 53 035 2 02 510 1 5 06 550 5 54 045 3 03 520 2 51 015 Rear View Mounting Hole 1 1 5 5 1 3 0 0 1000 6- 5 Grounding Hole Mounting Hole A A B B 1 4 Frame Cross Section A - A B - B 25 35 35 35 ELECTRICAL DATA | STC* CS3N 380MS 385MS 390MS 395MS 400MS 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp) 36.4 V 36.6 V 36.8 V 37.0 V 37.2 V Opt. Operating Current (Imp) 10.44 A 10.52 A 10.60 A 10.68 A 10.76 A Open Circuit Voltage (Voc) 43.7 V 43.9 V 44.1 V 44.3 V 44.5 V Short Circuit Current (Isc) 11.26 A 11.32 A 11.38 A 11.44 A 11.50 A 19.2% 19.4% 19.7%18.7% 18.9% Operating Temperature 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 61730 1500V) or TYPE 2 (UL 61730 1000V) or CLASS C (IEC 61730) 20 A Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m 2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3N 380MS 385MS 390MS 395MS 400MS 285 W 34.1 V 8.35 A 41.3 V 9.08 A 289 W 34.3 V 8.42 A 41.5 V 9.13 A 293 W 34.5 V 8.48 A 41.7 V 9.18 A 296 W 34.7 V 8.54 A 41.9 V 9.22 A 300 W 34.9 V 8.60 A 42.1 V 9.27 A Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. CANADIAN SOLAR (USA), INC. July 2021 | All rights reserved | PV Module Datasheet v2.7J25_F30_J3_NA 1622 E Trinidad Way08/30/23 solaredge.com SolarEdge Home Hub Inverter For North America SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) Optimized battery storage with HD-Wave technology Record -breaking 99% weighted efficiency with 200% DC oversizing Small, lightweight, and easy to install Modular design, future ready with optional upgrades to: DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge Home EV Charger Multi-inverter, scalable storage solution With enhanced battery power up to 10kW Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020, per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 12-25 YEAR WARRANTY HO M E B A C K U P 1622 E Trinidad Way08/30/23 SolarEdge Home Hub Inverter For North America SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) Applicable to inverters with part number SEXXXXH-USSNBBXX4 SE11400H – XXXXXBXX5 SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT – AC ON GRID Rated AC Power 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208 W Maximum AC Power Output 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208 W AC Frequency Range (min - nom - max)59.3 – 60 – 60.5(2)Hz Maximum Continuous Output Current @ 240V 16 25 32 42 47.5 A Maximum Continuous Output Current @ 208V 16 24 --48.5 A GFDI Threshold 1 A Total Harmonic Distortion (THD)< 3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if allowed)Yes Typical Nighttime Power Consumption < 2.5 W OUTPUT – AC BACKUP(3) Rated AC Power in Backup Operation(4)3800 6000 7600 10300 10300 W7600*10300* AC L-L Output Voltage Range in Backup 211 – 264 Vac AC L-N Output Voltage Range in Backup 105 – 132 Vac AC Frequency Range in Backup (min - nom - max)55 – 60 – 65 Hz Maximum Continuous Output Current in Backup Operation 16 25 32 43 43 A32*43* GFDI 1 A THD < 5 % OUTPUT – SOLAREDGE HOME EV CHARGER AC Rated AC Power 9600 W AC Output Voltage Range 211 – 264 Vac On-Grid AC Frequency Range (min - nom - max)59.3 – 60 – 60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery)40 Aac INPUT – DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT – DC (PV) Maximum DC Power @ 240V 7600 12000 15200 22000 22800 W15200*22800* Maximum DC Power @ 208V 6600 10000 --20000 W Maximum Input Current(5) @ 240V 10.5 16.5 20 27 31 Adc20*31* Maximum Input Current(5) @ 208V 9 13.5 --27 Adc Max. Input Short Circuit Current 45 Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % 2-pole Disconnection Yes * Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx. (1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x. (2) For other regional settings please contact SolarEdge support. (3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid. (4) Rated AC power in Backup Operation is valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated. (5) A higher current source may be used; the inverter will limit its input current to the values stated. 1622 E Trinidad Way08/30/23 SolarEdge Home Hub Inverter For North America SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) Applicable to inverters with part number SEXXXXH-USSNBBXX4 SE11400H – XXXXXBXX5 SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT – DC (BATTERY) Supported Battery Types SolarEdge Home Battery, LG RESU Prime(6) Number of Batteries per Inverter Up to 3 SolarEdge Home Battery, up to 2 LG RESU Prime Continuous Power(7)7600 10000 W Peak Power(7)7600 10000 W Max Input Current 20 26.5 Adc 2-pole Disconnection Yes SMART ENERGY CAPABILITIES Consumption Metering Built-in(8) Backup & Battery Storage With Backup Interface (purchased separately) for service up to 200A; up to 3 inverters EV Charging Direct connection to SolarEdge Home EV Charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular(9), Wi-Fi (optional), SolarEdge Home Network (optional) Revenue Grade Metering, ANSI C12.20 Built-in(8) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery)Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS AC Output and EV AC Output Conduit Size / AWG Range 1'' maximum / 14-4 AWG DC Input (PV and Battery) Conduit Size / AWG Range 1'' maximum / 14-6 AWG Dimensions with Connection Unit (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(10) in / mm17.7 x 14.6 x 6.8 / 450 x 370 x 174* Weight with Connection Unit 26 / 11.8 26 / 11.8 41.7 / 18.9 44.9 / 20.3 (10) lb / kg41.7 / 18.9* Noise < 25 < 25 < 50 dBA< 50* Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(11)˚F / ˚C Protection Rating NEMA 4 (6) The part numbers SExxxxH-USxMxxxxx only support the SolarEdge Home Battery. The part numbers SExxxxH-USxNxxxxx support both SolarEdge Home Battery and LG RESU Prime batteries. Requires supporting inverter firmware. (7) Discharge power is limited up to the inverter rated AC power for on-grid and backup applications. (8) For consumption metering current transformers should be ordered separately: SECT-SPL-225A-T-20 or SEACT0750-400NA-20 units per box. Revenue grade metering is only for production metering. (9) Information concerning the Data Plan's terms & conditions is available in the following link: SolarEdge Communication Plan Terms and Conditions.) (10) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4 will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (11) Full power up to at least 50°C / 122°F; for power de-rating information refer to the Temperature De-Rating Technical Note for North America. 1622 E Trinidad Way08/30/23 solaredge.com SolarEdge is a global leader in smart energy technology. By leveraging world-class engineering capabilities and with a relentless focus on innovation, SolarEdge creates smart energy solutions that power our lives and drive future progress. SolarEdge developed an intelligent inverter solution that changed the way power is harvested and managed in photovoltaic (PV) systems. The SolarEdge DC optimized inverter maximizes power generation while lowering the cost of energy produced by the PV system. Continuing to advance smart energy, SolarEdge addresses a broad range of energy market segments through its PV, storage, EV charging, UPS, and grid services solutions. SolarEdge @SolarEdgePV @SolarEdgePV SolarEdgePV SolarEdge www.solaredge.com/corporate/contact solaredge.com © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 23, 2023 DS-000189-NAM Subject to change without notice. Cautionary Note Regarding Market Data and Industry Forecasts: This brochure may contain market data and industry forecasts from certain third-party sources. This information is based on industry surveys and the preparer’s expertise in the industry and there can be no assurance that any such market data is accurate or that any such industry forecasts will be achieved. Although we have not independently verified the accuracy of such market data and industry forecasts, we believe that the market data is reliable and that the industry forecasts are reasonable. 1622 E Trinidad Way08/30/23 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents ƒRapid shutdown cables ƒMicro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): ƒ If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected – option 1 ƒIf the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-)BlaRed (+) with rapid shutdown resistor DC+ DC- 1622 E Trinidad Way08/30/23 solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules PO W E R O P T I M I Z E R 2 5 YEAR WARRANTY * Functionality subject to inverter model and firmware version 1622 E Trinidad Way08/30/23 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: November 8, 2022 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 S500B UNIT INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 125 Vdc MPPT Operating Range 8 – 60 12.5 – 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight (including cables) 655 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) For ambient temperatures above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers)25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6)See(6)13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. * 45mm for S500B 1622 E Trinidad Way08/30/23 solaredge.com SolarEdge Home Battery For North America BAT-10K1P Optimized for SolarEdge Home Hub Inverters(1) DC coupled battery featuring superior overall system efficiency, generating more energy to store and use for on-grid and backup power applications Integrates seamlessly with the complete SolarEdge Home ecosystem using SolarEdge Home Network, offering a single source for warranty, support, and training, to streamline logistics & operations Enhanced safety with Rapid Shutdown, SafeDC™ Qualified by the latest and most stringent UL fire safety standard Solar, storage, EV charging, and smart devices all monitored and managed by a single app to an optimized production, consumption, and backup* power Simple plug and play installation, with automatic SetApp-based configuration Flexible installation - wall or floor mount, all indoor or outdoor Wireless communication to the inverter, reducing wiring, labor, and installation BA T T E R I E S 10 YEAR WARRANTY * Backup applications are subject to local regulation and may require additional components and firmware upgrade 1622 E Trinidad Way08/30/23 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: August 14, 2022 DS-000167-NAM. Subject to change without notice. SolarEdge Home Battery For North America BAT-10K1P BAT-10K1PS0B-02 BATTERY SPECIFICATION Usable Energy (100% depth of discharge)9700 Wh Continuous Output Power 5000 W Peak Output Power (for 10 seconds)7500 W Peak Roundtrip Efficiency >94.5 % Warranty(1)10 Years Voltage Range 350-450 Vdc Communication Interfaces Wireless and RS485(2) Batteries per Inverter Up to 3(3) STANDARD COMPLIANCE Certification Cell UL1642 Battery UL1973, UL9540A, UL9540, UN38.3 Emissions FCC Part 15 Class B MECHANICAL SPECIFICATIONS Dimensions (W x H x D)31.1 x 46.4 x 9.84 / 790 x 1179 x 250 in / mm Weight 262 / 119 lb / kg Mounting Floor(4) or wall mount(5) Operating Temperature(6)+14 to +122 / -10 to +50 °F / °C Storage Temperature (more than 3 months)+14 to +86 / -10 to +30 °F / °C Storage Temperature (less than 3 months)-22 to + 140 / -30 to +60 °F / °C Altitude 6562 / 2000 ft / m Enclosure Protection IP55 / NEMA 3R - indoor and outdoor (water and dust protection) Cooling Natural convection Noise (at 1m distance)<25 dBA (1) For warranty details, see the SolarEdge Home Battery Limited Product Warranty. (2) The SolarEdge Home Battery is designed for use with SolarEdge Home Network for wireless communication. The inverter might require a matching SolarEdge Home Network Plug-in (more details below). Using RS485 could reduce the usable energy to 9500Wh. (3) Installations with multiple SolarEdge Home Battery connected to a single inverter require a pair of branch connectors (DC + and DC -) per battery excluding the last battery. The branch connectors should be purchased separately. (4) The floor stand is purchased separately. One floor stand is required per SolarEdge Home Battery. See the Accessories P/N table below. (5) Wall mount installation requires handles that should be purchased separately. See the Accessories P/N table below. (6) Note that operating the SolarEdge Home Batteries at extreme temperatures for extended durations of time may void the SolarEdge Home Battery warranty coverage. Please see the SolarEdge Home Battery Limited Product Warranty for additional details. SolarEdge Home Battery – Accessories (purchased separately) ACCESSORY P/N Floor stand IAC-RBAT-FLRSTD-01 Branch connectors set (includes a pair of DC + and DC - connectors) Required for installations with multiple SolarEdge Home Batteries with a single inverter IAC-RBAT-USYCBL-01 Handles IAC-RBAT-HANDLE-01 SolarEdge Home Network Plug-in ENET-HBNP-01 1622 E Trinidad Way08/30/23 (E)2x STUDS @ 16" O.C. W/ MIN. (2) 16d COMMON TOENAILS TO TOP/BOTTOM PLATE 9' - 0 " M A X . H E I G H T 2x4 BLK'G WHERE REQ'D W/ SIMPSON 'A35' CLIP EA. SIDE (E)SILL PLATE (E)DBL 2x TOP PLATE (N)SOLAREDGE ENERGY BANK (MAX. WT.: 270#) (4)1/4 " LAG SCREWS W/ 11 2" MIN. EMBED 1" M I N . T Y P . (E)WALLS SHALL HAVE 1 2" PLYWOOD, 1 2" DRYWALL OR 7 8" STUCCO 12'-6" MAX. TRIBUTARY WIDTH OF ROOF & FLOOR ABOVE 2x4 BLK'G WHERE REQ'D W/ SIMPSON 'A35' CLIP EA. SIDE9' - 0 " M A X . H E I G H T (E)2x4 STUDS @ 16" O.C., TYP. (4)1 4" LAG SCREWS W/ 11 2" MIN. EMBED (N)SOLAR EDGE ENERGY BANK (MAX. WT.: 270#) (4)1 4" LAG SCREWS W/ 11 2" MIN. EMBED N.T.S. SCALE:TYP. NOTES & SPECS 1N.T.S. SCALE: DETAILS McPHERSON ENGINEERING RYAN JAMES McPHERSON, P.E. JURUPA VALLEY, CA 92509 (909) 560-0066 SE@MCPE.GROUP E.O.R. SCALE: N.T.S PROJECT DESCRIPTION: BATTERY WALL MOUNT SHEET DESCRIPTION: EQUIPMENT WALL MOUNT 2 - 2 This item has been digitally signed and sealed on 10/4/2022 1)WORKING CLEARANCES AROUND BATTERY SYSTEM MINIMUM 3' WORKING CLEARANCES ARE REQUIRED AROUND THE SYSTEM FOR CODE COMPLIANCE 2)IF MORE THAN ONE SYSTEM IS INSTALLED - INDIVIDUAL ESS SYSTEMS SHALL BE SEPERATED FRIN EACH OTHER BY AT LEAST 3' EXCEPT WHERE SMALLER SEPERATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE SCALE FIRE TESTING COMPLYING WITH SECTION 1206.1.5 (CFC 1206.11.2.1) 1622 E Trinidad Way08/30/23 Intertek 3933 US Route 11 Cortland, NY 13045 Telephone: 607-753-7311 www.intertek.com Energy Storage System Test Verification of Conformity Applicant Name & Address Solaredge Technologies Ltd. 1 Hamada Street Herzeliya 4673335 ISRAEL Product(s) Tested Energy Storage System DCD-1PH-US-P4H-F-I, DCD-1PH-US-P4H-F-N, DCD-1PH-US-P6H-F-I, DCD-1PH-US-P6H-F-N, DCD-1PH-US-P3H-F-I, DCD-1PH-US-P2H-F-I, DCD-1PH-US-P3H-F-N, DCD-1PH-US-P2H-F-N. ESS Equipment List Equipment Manufacturer Model Inverter SolarEdge SE3000H-US, SE3800H-US SE6000H-US, SE7600H-US, SE10000H-US, SE11400H-US Storage Connection Unit SolarEdge DCD-1PH-US-P4H-F-I, DCD-1PH-US-P4H-F-N, DCD-1PH-US-P6H-F-I, DCD-1PH-US-P6H-F-N, DCD-1PH-US-P3H-F-I, DCD-1PH-US-P2H-F-I, DCD-1PH-US-P3H-F-N, DCD-1PH-US-P2H-F-N. Backup Interface SolarEdge BI-EUSGN-01, BI-NUSGN-01 Battery Pack SolarEdge BAT-10K1P LG Chem RESU10H type-R, RESU10H Prime RESU16H Prime Brand Name(s) SolarEdge Relevant Standard(s)Energy Storage Systems and Equipment [ANSI/CAN/UL 9540:2016 Ed.1] Verification Issuing Office 3933 US Route 11, Cortland, NY 13045 Verification/Report Number(s) 102311344CRT-001f NRTL Disclaimer, Different for each NRTL – Example: “This Verification is for the exclusive use of NRTL's Client and is provided pursuant to the agreement between NRTL and its Client. NRTL's responsibility and liability are limited to the terms and conditions of the agreement. NRTL assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification. Any use of the NRTL name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by NRTL. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply that the material, product, or service is or has ever been under an NRTL certification program.” Name: Mukund Rana Position: Engineering Team Leader Date: Jan-3rd - 2022 On the basis of the referenced test report(s), the sample(s) of the below product has been found to comply with the relevant standard(s) listed on this verification at the time the tests were carried out. 1622 E Trinidad Way08/30/23 FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out! PROTECT THE ROOF Install a high-strength waterproof attachment without lifting, prying or damaging shingles. FLASH LOC LOC OUT WATER With an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple Seal technology delivers a 100% waterproof connection. Cut Away View HIGH-SPEED INSTALL Simply drive lag bolt and inject sealant into the port 4 to create a permanent pressure seal. Cut Away View FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 3 2 4 1 TESTED TO TAS-100 WIND DRIVEN RAIN TEST AND UL441 RAIN TEST 1622 E Trinidad Way08/30/23 FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 FLASH LOC INSTALLATION GUIDE STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down-slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. PRE-INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4” below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32” pilot hole. Clean roof surface of dirt, debris, snow, and ice. Next, BACKFILL ALL PILOT HOLES WITH SEALANT. NOTE: Space mounts per racking system install specifications. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. NOTE: When installing included rail attachment hardware, torque nut to 30 ft/lbs. USE ONLY UNIRAC APPROVED SEALANTS: Chemlink Duralink 50 (included in kit) or Chemlink M-1 SEALANT GAP 1.75" 1622 E Trinidad Way08/30/23 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DRAWING 4/28/2020 FLASHLOC COMP KIT REVISION DATE: DRAWING TYPE: DESCRIPTION: FL - A 0 1 PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085D FLASHLOC COMP KIT DARK, 20 PACK 67 8 " 312 " 33 4" 214 " 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT FLASHLOC BASE MILL OR DARK SS SERRATED FLANGE NUT 1622 E Trinidad Way08/30/23 SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 1622 E Trinidad Way08/30/23 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONL I S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR Q UE S TI ON S OR C U S TOME R S E R VI C E VI S I T UN I R A C .C OM OR C A LL (5 0 5 ) 2 48 -2 7 0 2PUB2018AUG31 – PRINTED UPDATE 1622 E Trinidad Way08/30/23 Date_____________ To Whom it May Concern, I ______________________________ , the owner of the property located at, Property Owner Name ADDRESS:_________________________________________ I Have hired, Better Earth Electric Inc, State Lic #1024460, to install a PV Solar System: __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ Kind Regards , ________________________________ Signature ________________________________ Print Name Better Earth Electric Inc. 1815 E Wilshire Ave. St., 908/909, Santa Ana CA 92705 888-373-9379 SantaAnaPermits@Betterearth.solar 7/16/2023 LUZ RAMOS 1622 E TRINIDAD WAY ROOF MOUNTED PV SYSTEM SIZE OF 6000AC WITH 17 MODULES, OPTIMIZERS, 1 INVERTER ENERGY BANK 5.0KW, 9.7 kWh, MAIN SERVICE PANEL UPGRADE FROM (E)100A/100A TO (N)225A/200A LUZ RAMOS 1622 E Trinidad Way08/30/23 Signature Certificate Reference number: MTEL5-3AOUQ-8XVB8-RC5FK Document completed by all parties on: 16 Jul 2023 00:51:47 UTC Page 1 of 1 Signer Timestamp Signature Luz Ramos Email: luz-er@att.net Recipient Verification: Sent:16 Jul 2023 00:39:33 UTC Viewed:16 Jul 2023 00:39:37 UTC Signed:16 Jul 2023 00:51:47 UTC ✔Email verified 16 Jul 2023 00:39:37 UTC IP address: 107.77.228.156 Signed with PandaDoc PandaDoc is a document workflow and certified eSignature solution trusted by 40,000+ companies worldwide. 1622 E Trinidad Way08/30/23 Digitally sealed by RJM on Date: Job #: 23 - 13044 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group 8/18/23 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Ramos Residence 1622 Trinidad Way Santa Ana, CA 92701 8/18/23 Designed in Accordance with CBC 2022, ASCE 7-16 8/18/2023 12:21 PM 1 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 By: E.C Date: 8/18/23 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On-site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre-engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or descrepancies between current condition of the structure or otherwise as this letter describes before proceding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 8/18/2023 12:21 PM 2 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 By: E.C Date: 8/18/23 Location: 1622 Trinidad Way Santa Ana, CA 92701 Existing Structure Info: Number of Stories = 1 Aroof = 2317 sq. ft. Roof Square Footage A3rd_flr = 0 sq. ft. Third Floor Square Footage (if applicable) A2nd_flr = 0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Lattitude = Longitude = Ss = 1.286 S1 = 0.459 Exposure Category = C Ult. Wind Speed = 130 m.p.h. P.V. Array Info: Model = CS3N-390MS Height of Panel = 76.40 in. Width of Panel = 41.30 in. Area of Panel = 21.9 ft.2 Number of New Panels = 17 Number of Exis. Panels = 0 Total Area of Array = 372.5 ft.2 Spacing of Anchors = 4.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 7-27 deg 33.749640 -117.846518 Project Info 8/18/2023 12:21 PM 3 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 By: E.C Date: 8/18/23 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x6 Trusses Misc = 1.0 p.s.f. DLr1 = 8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f. Drywall and framing DLr2 = 10.0 p.s.f. Total Existing Roof Dead Load LLr = 20.0 p.s.f. Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels = 2.8 p.s.f. weight of panels including rack system DLr1_proposed = 10.8 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 12.8 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) = 64.9 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) = 58.5 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - Wex = -9.90% TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! Wex 8/18/2023 12:21 PM 4 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 By: E.C Date: 8/18/23 Seismic Design Parameters Risk Category = 2 Per Table 1-5-1 R = 6.5 Response Modification Factor (Table 12-2.1) Site Class = D Per 11.4.2 Ie = 1 Seismic Importance Factor (Table 1.5-2) Ss = 1.29 Short Period P.G.A. S1 = 0.46 1-Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa = 1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv = 1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa = 1.54 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv = 0.78 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) = 1.03 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) = 0.52 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 15 ft Ct = 0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T = 0.15 sec Approximate Fundamental Period TL = 8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.79 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie = 0.05 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R = 0.04 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 ≥ 0.6g CS = 0.16 Design Seismic Coefficient Check Additional Base Shear Wexisting = 23.2 kips Weight of Existing Structure Wpanels = 1.0 kips Weight of Proposed Panels Vexisting = Cs Wexisting = 3.7 kips Roof Level Shear of Existing Structure Vpanels = Cs Wpanels = 0.2 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn) x = 4.44% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 8/18/2023 12:21 PM 5 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 By: E.C Date: 8/18/23 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult = 130 mph Kzt = 1.00 (sec 26.8.2) h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd = 0.85 (sec 26.6) Roof θ = 7-27 deg Ke = 1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V 2 qh = 31.26 (eq. 26.10-1) GPp = -2 uplift γE = 1.5 (sec 29.4.4) γa = 0.76 (fig 29.4-8) γE = 1.5 FIG 29.4-7)γc = 0.98 (fig 29.4-7) hpt = 0 γa = 0.76 (fig 29.4-8)γp = 0.9 (fig 29.4-7)ω = 0.00 deg (panel tilt) GPp = -2 uplift GCrm = 1.4 uplift p = qh (GPp) γE γa (eq 29.4-7)p = qh (GCrn) γE γC γp (eq 29.4-6) p = -71.1 p.s.f.p = 58.0 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL = 2.8 p.s.f.dead load of panel (inlcuding rack system) W = 71.1 p.s.f.wind load normal to face of panel Arealag = 12.7 sq. ft.area tributary to each anchor SPanc = 4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) = 522.0 lbs total uplift on anchor Material = DFL lumber anchor material Dialag = 5/16 in. diameter of screw Penlag = 2.5 in. min. penetration to existing framing Wlag = 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews = 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor Puplift Pallow Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) = 0.61 < 1.00 Anchor is OK! 8/18/2023 12:21 PM 6 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 By: E.C Date: 8/18/23 Gravity Loads: DEMAND DECREASED BY 9.9% = OK! Lateral Loads: DEMAND INCREASED BY 4.44% < 10% = OK! Anchorage: DEMAND OF 522.LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 8/18/2023 12:21 PM 7 of 7 ©McPherson Engineering 1622 E Trinidad Way08/30/23 Rev: 8/29/19 S OL-01 C BC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: Th e licensed contractor of record sh all complete all sections, answer the ten q uestions and sign the certification section below. A copy of th is form sh all be attached to each of TW O sets of plans , of minimum 11 ” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. W ill th e PV system layou t provid e the required th ree -foot wide clear access path way s per S ection 605.1 1 of th e C alifornia Fire C od e, and is th is sh own on th e roof plan? 2. W ill th e PV system be installed on a roof having only one roofing layer with no overlays? 3. W ill th e PV array be flu sh mou nted to th e existing roof so th at the plane of th e mod ules (panels) are parallel to th e plane of th e roof? 4. W ill th e PV system weig h maximum 4 pounds per square feet or less? 5. W ill th e PV system be installed wh ere the mod ules do not overh ang any roof ed g es (such as eaves, gabled end s, ridg es and hips)? 6. W ill th e PV system be installed with a space of 2” minimum to 10” maximum between th e u nderside of mod ule s and the surface of the roof? 7. W ill th e PV system be installed withou t u sing any ballast system or counter-weight system? 8. W ill th e anch ors be installed with a maximum horizontal anch or spacing of 6 feet and is this maximum h orizontal spacing shown on the plans? 9. W ill th e minimum 5/1 6” lag screws be installed with a minimum of 2 -1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL th e stru ctu ral pages of the plans stamped and signed by a C alifornia licensed professional eng ineer? (inclu ding project specific site plan, PV layou t, anchorage spacing , anchorag e details and manufactu rer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: S ignature: Ph one Number: Date: Email Ad d ress: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST BETTER EARTH ELE C TRIC INC 1024460 VIC TORIA RUIZ 323-398-9324 VIC TORIA.R@BETTEREARTH.S OLAR 8/22/2023 1622 TRINIDAD WAY 1622 E Trinidad W ay08/30/23