Loading...
HomeMy WebLinkAbout826 N Lacy St - PlanREVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 SHEET INDEX COVER SHEET PV-1 SITE PLAN PV-2 STRUCTURAL LAYOUT DETAIL PV-3 SINGLE-LINE DIAGRAM PV-4 LABELS PV-5 SPECIFICATION SHEETS SS-6+ GOVERNING CODESVICINITY MAP DESIGN CRITERIA OCCUPANCY TYPE: U RISK CATEGORY: CATEGORY II WIND SPEED: 95 MPH ASCE 7-22 WIND EXPOSURE: B SNOW LOAD: 0 CONSTRUCTION TYPE: VB N PV-1 COVER SHEET GENERAL NOTES SCOPE OF WORK STAMPS & SIGNATURES 1. ALL WORK SHALL COMPLY WITH 2020 NEC, 2022 CEC, 2022 CRC, 2022 CFC, 2022 CBC, 2022 CEES, AND 2022 CGBSC. 2. ALL WORK SHALL BE COMPLETED BY QUALIFIED PERSONNEL. 3. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS' INSTALLATION SPECIFICATIONS AND THE 2022 CEC. 4. PHOTOVOLTAIC PANELS ARE TESTED, LISTED, AND IDENTIFIED WITH A FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703 AND UL 61730. 5. PHOTOVOLTAIC PANELS, RACKING SYSTEM, AND INVERTERS ARE TESTED AND LISTED UNDER UL 2703. 6. INVERTERS ARE LISTED UNDER UL 1741, UL 1741-SA, AND UL 1741-SB. 7. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT SERVICE ENTRANCE. 8. SYSTEM SHALL COMPLY WITH CEC 690.12 REQUIREMENT FOR RAPID SHUTDOWN. 9. SYSTEM SHALL BE INTERCONNECTED ONLY AFTER RECEIVING APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY. 10. EACH PV SYSTEM DISCONNECTING MEANS SHALL BE PERMANENTLY MARKED TO IDENTIFY IT AS A PV SYSTEM DISCONNECT. 11. MEANS SHALL BE PROVIDED TO DISCONNECT EQUIPMENT AND ALL UNGROUNDED DC CONDUCTORS OF THE PV SYSTEM FROM ALL OTHER CONDUCTORS IN A BUILDING OR OTHER STRUCTURE. 12. APPROVED SMOKE ALARMS ARE REQUIRED TO BE INSTALLED PER CRC R314, IN EACH SLEEPING ROOM, OUTSIDE OF EACH SEPARATE SLEEPING ROOM, AND AT EACH STORY INCLUDING HABITABLE BASEMENT. BATTERY-OPERATED ALARMS ARE ACCEPTABLE FOR PHOTOVOLTAIC INSTALLATIONS. 13. APPROVED CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED PER CRC R315, OUTSIDE OF EACH SEPARATE SLEEPING ROOM, AND AT EACH STORY INCLUDING HABITABLE BASEMENT. BATTERY OPERATED DEVICES ARE ACCEPTABLE FOR PHOTOVOLTAIC INSTALLATIONS. 14. APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 365 DAYS FOLLOWING THE DATE OF APPLICATION SHALL AUTOMATICALLY EXPIRE. 15. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS, A SUCCESSFUL INSPECTION IS NOT OBTAINED WITHIN 180 DAYS. PERMITS WHICH HAVE BECOME INVALID SHALL PAY A RENEWAL FEE. INSTALL NEW SOLAR ROOFTOP PHOTOVOLTAIC SYSTEM ON A DETACHED GARAGE AS A SUPPLEMENTAL ELECTRICAL SUPPLY SYSTEM CONNECTED TO THE UTILITY SUPPLY THROUGH THE SERVICE EQUIPMENT. SYSTEM SIZE: 2.600 kW DC / 2.314 kW CEC-AC EQUIPMENT: MODULE: (8) JINKO SOLAR JKM325PP-72 (325W) INVERTER: (8) ENPHASE ENERGY IQ8PLUS-72-2-US (240V) COMBINER BOX: (1) ENPHASE ENERGY X2-IQ-AM1-240-4C (WITH IQ GATEWAY) RACKING: SNAPNRACK ULTRA RAIL UR-40 ATTACHMENT: SNAPNRACK ULTRA RAIL UMBRELLA L FOOT & FLASHING RACKING TYPE: ROOF MOUNT ATTACHMENT TYPE: FLUSH MOUNT BUILDING/ STRUCTURE: DETACHED GARAGE NUMBER OF STORIES: 1 BUILDING SQUARE FOOTAGE: SINGLE FAMILY DWELLING: 1869 SQFT DETACHED GARAGE: 441 SQFT ELECTRICAL: (E) MAIN SERVICE PANEL 200A MAIN / 225A BUS 120/240 VAC SINGLE-PHASE, 3-WIRE END-FED 120% RULE: 70A MAX SOLAR OCPD: 20A 2020 NATIONAL ELECTRICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE www. Loyd W Martin .com Solar Structures Engineering #2023-4435 Structural Only August 8, 2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101116334 Elec# 20180694 Issued 08/24/23 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 SLD PV-4 NOTES SYSTEM SIZE DC RATING 2.600 kW CEC-AC RATING 2.314 kW VOLTAGE DROP % ONE-WAY DISTANCE Imax OHMS/kFT (PER T-8) NOMINAL VOLTAGE VOLTAGE DROP 50 FT 9.68 A 1.98 240 V 9.68 A x [1.98 OHMS/kFT] x [50' x 2/1000'] / 240 V x 100 % = 0.8 % < 2 % >> OK + - + - + - + - (E) 200A MAIN / 225A BUS END-FED 120/240VAC, 1PHASE, 3W ELECTRICAL SERVICE ENTRANCE (N) 20A 2P PV OCPD (E ) L O A D S (E) 200A MAIN OCPD(N) AC DISCONNECT NON-FUSIBLE LOCKABLE SWITCH 30A/240V 2P, NEMA 3R (N) AC COMBINER ENPHASE ENERGY X2-IQ-AM1-240-4C 125A BUS WITH (1) 15A 2P IQ GATEWAY OCPD AND (1) 20A 2P PV OCPD JUNCTION BOX NEMA 4X (8) PV MODULES JINKO SOLAR JKM325PP-72 (8) MICROINVERTERS ENPHASE ENERGY IQ8PLUS-72-2-US (240V) (E) GEC CONDUCTOR SIZING CALCULATIONS Imax (690.8(A)) Icont (690.8(B)(1)) CONDUCTOR TYPE AMPACITY @ 75°C RATING AMBIENT TEMP FACTOR # OF CURRENT-CARRYING CONDUCTORS DERATED AMPACITY @ 90°C RATING (690.8(B)(2)) 1 (8) x 1.21 A = 9.68 A 9.68 A x 1.25 = 12.1 A #12 THWN-2 25 A > Icont >> OK 0.91 1-3 >> 1.00 30 A x 0.91 x 1.00 = 27.3 A > Imax >> OK CONDUIT SCHEDULE CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE MFG Q-CABLES NONE (1) #6 BARE COPPER 2 1/2" EMT OR EQUIVALENT (2) #12 THWN-2 NONE (1) #8 THWN-2 3 1/2" EMT OR EQUIVALENT (2) #12 THWN-2 (1) #12 THWN-2 (1) #8 THWN-2 1. LOWEST AND HIGHEST EXPECTED AMBIENT TEMPERATURE ARE BASED ON ASHRAE DRY BULB EXTREMES (2°C MIN, 39°C MAX). 2. RACEWAYS ARE GREATER THAN 7/8TH INCHES ABOVE ROOF SURFACE. NO TEMPERATURE ADDER REQUIRED. NEC 2020 310.15(B)(2). 3. INVERTER IS COMPLIANT WITH CALIFORNIA RULE 21 UL 1741-SA AND IEEE 1547:2018 UL 1741-SB. 4. THE SYSTEM IS AN UNGROUNDED ARRAY. ALL EQUIPMENT GROUNDING MADE VIA MECHANICAL MEANS OR BY A #8 AWG GROUNDING CONDUCTOR. 5. MODULES, INVERTERS, AND RACKING SYSTEM UTILIZE GROUNDING PER UL 2703. 6. SYSTEM SHALL COMPLY WITH CEC 690.12 REQUIREMENT FOR RAPID SHUTDOWN. 7. PV OCPD AT POINT OF INTERCONNECTION INSTALLED AT OPPOSITE END FROM INPUT FEEDER SHALL COMPLY WITH THE 120% RULE PER NEC 705.12 (B)(3)(2 & 4). AC COMBINER BOX MODEL BRAND ENPHASE ENERGY MODEL NUMBER X2-IQ-AM1-240-4C SYSTEM VOLTAGE 120/240 VAC BUSBAR RATING 125 A MAX OUTPUT CURRENT 65 A MAX OCPD RATING 80 A MICROINVERTER MODEL BRAND ENPHASE ENERGY MODEL NUMBER IQ8PLUS-72-2-US (240V) POWER RATING 290 VA NOM. AC VOLTAGE 240 V MAX OUTPUT CURRENT 1.21 A START VOLTAGE 22 V / 58 V MAX UNITS/BRANCH 13 MAX DC INPUT Isc 25 A PV MODULE MODEL BRAND JINKO SOLAR MODEL NUMBER JKM325PP-72 Pmax 325 W Voc 46.7 V Vmp 37.6 V Isc 9.10 A Imp 8.66 A 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 LABELS PV-5 PLACARD ATTACHED TO MAIN SERVICE PANEL LABELS ATTACHED TO INVERTER/AC COMBINER BOX LABEL ATTACHED TO CONDUITS AT EVERY 10 FEET LABEL ATTACHED TO MAIN SERVICE PANEL LABELS ATTACHED TO AC DISCONNECT LABEL PLACED NEXT TO SOLAR BREAKER INSIDE MAIN SERVICE PANEL LABEL ATTACHED TO JUNCTION BOX NOTES 1. PLACARD SHALL BE PLASTIC WITH MACHINE-ENGRAVED WHITE LETTERING ON RED BACKGROUND, AND ATTACHED TO MAIN SERVICE PANEL WITH POP-RIVETS OR SCREWS. 2. ALL SIGNAGES SHALL BE CLEARLY LABELED WITH WHITE LETTERING ON RED BACKGROUND, ALL CAPITALS, ARIAL OR SIMILAR FONT, 3/8" MINIMUM LETTER HEIGHT, REFLECTIVE, WEATHER RESISTANT MATERIAL. 3. LABEL FOR RAPID SHUTDOWN SWITCH SHALL BE LOCATED NO MORE THAN 3 FEET FROM THE SWITCH. 240 OPERATING VOLTAGE = 240 V / MAX. CURRENT = 20 A WARNING: DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN * DO NOT RELOCATE PV OVERCURRENT DEVICE * 826 LACY ST, SANTA ANA, CA 92701 SOLAR INSTALLER: GRID ALTERNATIVES,GLA CA.PHONE: 310.735.9762 SOLAR MODULES ARE ON THE ROOF (1) MAIN SERVICE PANEL (2) AC DISCONNECT (3) AC COMBINER BOX YOU ARE HERE (1) (2), (3) 9.68 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 LEGEND ARRAY KEY ARRAY - #AZIMUTH PITCH 01 243°10:12 (39°) 02 63°10:12 (39°) ARRAY COVERAGE ARRAYS COVER APPROXIMATELY 27% OF AVAILABLE ROOF SPACE. NOTES LADDER ACCESS POINT 1. ROOF ACCESS AND PATHWAYS ON DETACHED GARAGE ARE EXEMPT PER CFC 1205.2 & CRC R324.6 EXCEPTION 1. 2. LADDER ACCESS POINTS SHALL BE LOCATED AT UNOBSTRUCTED, STRONG POINTS OF BUILDING CONSTRUCTION. 3. WORKSPACE CLEARANCE AROUND ALL ELECTRICAL EQUIPMENT SHALL BE AT LEAST 30" WIDE AND 36" IN FRONT OF EQUIPMENT (NEC 110.26) 4. ALL PV ELECTRICAL EQUIPMENT SHALL BE INSTALLED AT LEAST 36" AWAY FROM ANY EXISTING GAS RISER. 5. CONDUIT SHALL RUN UNDER ROOF EAVE. 1/2" EMT FLUSH-MOUNTED 1" OR GREATER ABOVE ROOFTOP. 6. CONDUIT SHALL BE HIDDEN AND PAINTED TO MATCH WITH BUILDING WALL. 7. SYSTEM SHALL COMPLY WITH CEC 690.12 REQUIREMENT FOR RAPID SHUTDOWN.SITE PLAN SCALE: 1/16" = 1' N PV-2 SITE PLAN PROPERTY LINES 21' 1" 6' 7" 8' 7" 150' 3" 50' (N) ARRAY - 01 (N) ARRAY - 02 (E) MAIN SERVICE PANEL (N) AC COMBINER BOX (N) AC DISCONNECT (STACKED) 21' 6' 9" 37' 8" FIRE SETBACKS EXCEPTION CFC 1205.2 & CRC R324.6 22' LA C Y S T DETACHED GARAGE DRIVEWAY SFD AL L E Y 2.600 kW DC / 2.314 kW CEC-AC SOLAR ELECTRIC SYSTEM MODULE MICROINVERTER COMBINER BOX (1) ENPHASE ENERGY X2-IQ-AM1-240-4C WITH IQ GATEWAY (8) ENPHASE ENERGY IQ8PLUS-72-2-US (240V) (8) JINKO SOLAR JKM325PP-72 www. Loyd W Martin .com Solar Structures Engineering #2023-4435 Structural Only August 8, 2023 NOTE: Engineer of Record assumes that all structural components of the existing building were permitted and met the requirements of the Building Code at the time of construction. Solar Contractor shall field verify that the roof framing is in its existing permitted condition and capable of supporting required live loads. Framing specified on solar plans shall be assumed to be minimum size and spacing, actual framing may be different. 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 STRUCTURAL LAYOUT PV-3 STRUCTURAL INFORMATION # OF STORIES 1 ROOF TYPE COMPOSITION SHINGLES # OF LAYERS 1 FRAME TYPE 2" x 4" ENGINEERED TRUSSES RAFTER/TRUSS SPACING 24" OC MAX UNSUPPORTED RAFTER SPAN 6' - 10" ATTACHMENT TYPE FLUSH MOUNT # OF ATTACHMENTS 16 ARRAY AREA 167.26 SQFT ARRAY WEIGHT 535.44 LBS POINT LOAD 33.47 LBS/ATTACHMENT DISTRIBUTION LOAD 3.2 PSF STRUCTURAL LAYOUT SCALE: NTS N ARRAY - 01 PITCH: 10:12 (39°) AZIMUTH: 243° NOTES: 1. ROOF PENETRATIONS ARE SEALED WITH CHEMLINK M1 AND FLASHINGS. 2. ARRAYS SHALL NOT COVER ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 3. INSTALLERS TO VERIFY RAFTER SIZE AND SPACING. 4. SYSTEM SHALL NOT HAVE ANY HANGING WIRES UNDERNEATH THE PV PANELS.MAX ATTACHMENT SPACING: 4' SCALE: NTS ROOF ATTACHMENT DETAIL SCALE: NTS 39.1" 77.0" 4' 6' 5" 4' 5" 3' 4' 5" 3' 13' 3" 6' 5" 13' 3" (N) 4 - MICROINVERTERS (N) 4 - MICROINVERTERS SNAPNRACK ULTRA RAIL UMBRELLA L FOOT SNAPNRACK ULTRA RAIL UR-40 2" x 4" ENGINEERED TRUSSES @ 24" OC N ARRAY - 02 PITCH: 10:12 (39°) AZIMUTH: 63°3" - 6" SNAPNRACK ULTRA RAIL UR-40 PV MODULE SNAPNRACK COMP FLASHING SNAPNRACK ULTRA RAIL UMBRELLA L FOOT (1) 5/16" x 4" SS UMBRELLA LAG SCREW 2-1/2" MINIMUM EMBEDMENT INTO FRAMING 2" x 4" ENGINEERED TRUSSES @ 24" OC www. Loyd W Martin .com Solar Structures Engineering #2023-4435 Structural Only August 8, 2023 826 N Lacy St 08/30/23 www.jinkosolar.com PowerWarranty PID-FREE 2400 Pa 5400 Pa RESISTANT LOW LIGHT CLIMATE DURABILITY KEY FEATURES Through the internal nano-level reflection technology to improve the power output, Polycrystalline 72-cell module achieves a power output up to 325Wp LINEAR PERFORMANCE WARRANTY JKM325PP-72(Plus) Positive power tolerance of 0/+3% 310-325Watt POLY CRYSTALLINE MODULE ISO9001:2008 ISO14001:2004 OHSAS18001 certified factory. IEC61215 IEC61730 certified products. Extreme high efficiency module: Through the unique high reliability encapsulating technology to make sure the module possess anti-PID characteristics under high temperature and humidity for a long time, Have passed anti-PID test 60 /85% RH condition for 1000h Anti-PID Guarantee: Advanced glass and surface texturing allow for excellent performance in low-light environments. Low-light Performance: Certified to withstand: wind load (2400 Pascal) and snow load (5400 Pascal). Severe Weather Resilience: 100% 97.5% 90% 80.7%Gu a r a n t e e d P o w e r P e r f o r m a n c e New linear performance warranty High salt mist and ammonia resistance certified by TUV NORD. Durability against extreme environmental conditions: Improved temperature coefficient decreases power loss during high temperatures. Temperature Coefficient: Plus 826 N Lacy St 08/30/23 Engineering Drawings SPECIFICATIONS Mechanical Characteristics Electrical Performance & Temperature Dependence Packaging Configuration 35 404.5 14 95.5 70 70 3 8 19 5 6 992 40 10 0 86 0 13 6 0 L 942 Installing Holes Label Junction box Cathode - + Anode Connector Grounding Holes A A Current-Voltage & Power-Voltage Curves (310W) Temperature Dependence of Isc,Voc,Pmax Isc Voc Pmax 2-Ø4 ² 5 10 15 20 25 30 35 0 40 45 0 1 2 3 4 5 6 7 8 9 10 0 45 90 135 180 225 270 315 -40 1000VDC (IEC) 15A 0~+3% -0.40%/ -0.30%/ 0.06%/ 45±2 JKM310PP(Plus) 310Wp 37.0V 8.38A 45.9V 8.96A 15.98% 231Wp 6.81A 33.9V 42.7V 7.26A JKM315PP(Plus) 315Wp 37.2V 8.48A 46.2V 9.01A 16.23% 235Wp 6.84A 34.3V 43.2V 7.29A ~+85 JKM320PP(Plus) 320Wp 37.4V 8.56A 46.4V 9.05A 16.49% 238Wp 6.86A 34.7V 43.7V 7.30A JKM325PP(Plus) 325Wp 37.6V 8.66A 46.7V 9.10A 16.75% 242Wp 6.91A 35.0V 44.0V 7.34A 826 N Lacy St 08/30/23 826 N Lacy St 08/30/23 826 N Lacy St 08/30/23 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery • Supports Wi-Fi, Ethernet, or cellular connectivity • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) 826 N Lacy St 08/30/23 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage) 64A Max. fuse/circuit rating (output) Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input) IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD) Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Wire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors • 60A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Altitude INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C 826 N Lacy St 08/30/23 mwatkins Solar Mounting Solutions B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in Iyy 0.132 in Sx (TOP) 0.150 in³ Sx (BOT) 0.158 in³ Sy (LEFT) 0.175 in³ Sy (RIGHT) 0.175 in³ 9-21 826 N Lacy St 08/30/23 MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 802 UP, 1333 DOWN, 356 SIDE 2005 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 0.79 - 1.03 REVISION: mwatkins C PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA RAIL UMBRELLA L FOOT, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK232-01375, 232-01376, 232-0137713 3 1 2 9-21 826 N Lacy St 08/30/23 ALL DIMENSIONS IN INCHES REVISION: mwatkins C 11.75 3.25 8.75 .45 6.75 4.20 .30 1.50 .30 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM 232-01377 COMP FLASHING, 9" X 12", BLACK GALVALUME .35 1.00 105° 1.00 SLOT .38 1.62 2.78 1.78 1.501.80 3.25 1.37 .30 .25 9-21 826 N Lacy St 08/30/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2 -1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 826 N Lacy St 08/30/23 Structural Calculations for a Roof Mounted Solar Photovoltaic System for: Habitat for Humanity OC 826 N Lacy St Santa Ana, CA 92701 Applicable Codes: 2022 California Building Code, 2022 California Electric Code, 2022 California Mechanical Code, American Society of Civil Engineers Standard ASCE 7-16 Minimum Design Loads for Buildings and Other Structures, American Wood Council 2018 National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adopted by reference or enacted by law. Assumed Design Parameters: The existing structure has been built under a building permit and is in its original condition. The existing roof structure is capable of its code required live load and the ability of the roof structure to support live loads has not been substantially reduced by the age of the structure, termites or mold, or unauthorized modifications to the existing structure. Solar Energy Contractor shall make an inspection of the existing roof framing system prior to installation of the roof mounted solar energy system to verify that the existing roof is capable of supporting minimum roof live loads. Assumed Design Parameters: All 2x members are grade Douglas Fir #2 or better All 4X members are grade Douglas Fir #1 or better All Roof Connectors are Simpson Strong-Tie or Equal All Concrete Foundations are f'c = 2500 psi or stronger Sht # 1 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Original Structure was built to the Type-V Wood Framed Standards of the Applicable Building Code at the time of Construction. 826 N Lacy St 08/30/23 Note to Building Official: Based upon a review of the proposed plans I am confident that the existing roof framing system is capable of safely supporting the additional loads caused by the new solar photovoltaic energy system. The contractor shall field verify that the existing roof structure is in its original permited condition and verify that it can support the normal code required roof live loads. Attached in this package are several calculations showing that the roof members can support the additional weight of the solar array. Furthermore, an analysis of the solar array's support for wind forces and a seismic analysis of the existing structure are also included. Check Existing 2X4 Roof Trusses @ 24" O.C.: w = 30 psf x 2 ft. = 60 plf Total load on trusses = 60 plf x 14.3 ft. = 858 lbs Sht # 2 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com 5 :'/// 5 14.3' 826 N Lacy St 08/30/23 Check Existing 2X4 Roof Trusses @ 24" O.C.: Snow Load = 0 psf Dead Load = 14 psf Live Load = 16 psf WDL + LL = 30 psf x 2 ft. = 60 plf WDL = 14 psf x 2 ft. = 28 plf w = 30 psf x 2 ft. = 60 plf Total load on trusses = ( 60 plf x 7.9 ft ) + ( 28 plf x 6.4 ft ) + ( 4' x 3.2' x 3 psf x 2 ) = 730 lbs < 858 lbs OK OK. Per 2022 California Existing Building Code Section 503.3 Alterations Check attachment of Support to Existing Structure for Wind Uplift CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2. NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA: FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT BE LESS THAN ONE-THIRD ITS LENGTH. EFFECTIVE AREA = 15 SQ FT Sht # 3 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com % CHANGE =730 lbs - 858 lbs x 100 = -14.9% < 5% OK858 lbs Z //Z '/ 55   3 3 826 N Lacy St 08/30/23 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Tributary Area to Each Solar Mount = 4 ft. x 3.2 ft. = 12.8 sq. ft. ( Max ) Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C): p = q h (GC p )(γE )(γ a )Eq'n 29.4-7 ASCE 7-16 q h = 0.00256 K z K zt K d K e V2 Eq'n 26.10-1 ASCE 7-16 Note: K z = velocity pressure coefficient Section 29.10.1 ASCE 7-16 K z = 0.9 (Exposure C, Height = 20 ft or less) K zt = Topographical Factor = 1.0 K d = Wind Directionality Factor = 0.85 K e = Ground Elevation Factor = 1.0 V = 130 mph ; VASB = 101 mph q h = 0.00256 (0.9) (1.0) (0.85) (1.0) (101)² q h = 19.98 psf GC p = -2.0 (Zone 2 ; Effective Area = 15 sq. ft. ) γE = Exposure Factor = 1.5 γa = Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4-8 ASCE 7-16 p = q h (GC p )( γE )( γa ) p = 19.98 psf (-2.0) (1.5) (0.7) = 42 psf Sht # 4 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com 826 N Lacy St 08/30/23 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Nominal (Unfactored) Uplift at each support = 42 psf x 12.8 sq. ft. = 537.6 lbs Note: Section 2.4.1 of ASCE 7-16, Basic Load Combinations for Allowable Stress Design. Note: Applicable Load Combination #5 (D + 0.6W) Design (Factored) Uplift at each support = 0.6 x 537.6 lbs = 323 lbs Load per lag screw = 323 lbs / 1 = 323 lbs Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below according to the 2018 NDS. W ' = W x Cd x Ct Table 10.3.1 2018 NDS where W = 266 lbs / in. of embedment per Table 12.2a Cd = 1.6 per Table 2.3.2 of 2018 NDS Ct = 1.0 per Table 2.3.3 of 2018 NDS W' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 323 lbs OK Sht # 5 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Use Support connected to 2x Min. Roof Member w/ (1) 5/16" x 4" lag screws per connection minimum. 826 N Lacy St 08/30/23 Check Seismic load due to added dead load of photovoltaic system. Determine Seismic Weight of Existing Building: Effective Existing Seismic Weight Area of (E) Building = Approximately 600 Sq. ft Approximate Effective = 600 sq. ft. x 15 psf ave. = 9,000 LBS Seismic Weight DETERMINE BASE SHEAR V = Cs W EQ'N 12.8-1 ASCE 7-16 EQ'N 12.8-2 ASCE 7-16 R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1 R = 6.5 WOOD SHEAR WALLS Ie = 1.0 IMPORTANCE FACTOR SDS = 2/3 x SMS SMS = FA x SS SMS = 1.2 x 1.5 = 1.8 SDS = 2/3 x 1.8 = 1.2 Cs == 0.185 EQ'N 12.8-2 ASCE 7-16 Sht # 6 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Cs = SDS R Ie SDS R Ie 826 N Lacy St 08/30/23 EXISTING BASE SHEAR V = 0.185 x 9,000 LBS = 1,665 LBS DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING SEISMIC = 9,000 LBS WEIGHT NEW SOLAR ARRAY = 3 PSF x 8 PANELS x 6.4' x 3.3' = 507 LBS NEW SEISMIC = 9,000 LBS + 507 LBS = 9,507 LBS WEIGHT THEREFORE NEW BASE SHEAR: V = 0.185 x 9,507 = 1,759 LBS EQ'N 12.8-1 ASCE 7-16 OK. PER ASCE 7-16 SECTION 11B.4 ALTERATIONS EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT FROM ANALYSIS SINCE NEW SEISMIC FORCE IS LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE Sht # 7 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 "Alterations may be made to any structure without requiring the existing structure to comply with this standard, provided that the alterations comply with the requirements for a new structure. Alterations that increase the seismic force in any existing structural element by more than 10% or decrease the design strength of any existing structural element to resist seismic forces by more than 10% shall not be permitted unless the entire seismic force-resisting system is determined to comply with this standard for a new structure." End of Calculations Email: loydwmartin@gmail.com www.loydwmartin.com % CHANGE =1,759 LBS - 1,665 LBS x 100 = 5.6 % < 10 % OK 1,665 LBS 826 N Lacy St 08/30/23 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 826 N Lacy St 08/30/23 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 826 N Lacy St 08/30/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan 826 N Lacy St 08/30/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 826 N Lacy St 08/30/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram 826 N Lacy St 08/30/23 23/08/2023, 10:51 GRID Alternatives Mail - Letter of approval for Lacy Street projects https://mail.google.com/mail/u/0/?ik=679fea25c8&view=pt&search=all&permmsgid=msg-f:1774673989055701694&simpl=msg-f:1774673989055701694 1/1 Freida Galindo <fgalindo@gridalternatives.org> Letter of approval for Lacy Street projects Allan Cabrera <allan@habitatoc.org> Sat, Aug 19, 2023 at 9:03 AM To: Malcolm Vivian <mvivian@gridalternatives.org> Cc: Freida Galindo <fgalindo@gridalternatives.org>, Raymond Harrison <raymond@habitatoc.org>, Rita Ross <rita@habitatoc.org>, Mike Speck <mikes@habitatoc.org> Hi Malcolm, Apologies for the delayed response. Please see below. Habitat for Humanity authorizes GRID alternaƟves to install rooŌop solar at the following addresses: 826 North Lacy Street, Santa Ana 92701 830 North Lacy Street, Santa Ana 92701 Thank you, From: Malcolm Vivian <mvivian@gridalternatives.org> Sent: Friday, August 18, 2023 4:59 PM To: Lauren Hahn <lauren@habitatoc.org> Cc: Freida Galindo <fgalindo@gridalternatives.org>; Allan Cabrera <allan@habitatoc.org> Subject: Re: LeƩer of approval for Lacy Street projects CAUTION: This email originated from outside of the organizaƟon. Do not click links or open aƩachments unless you recognize the sender and know the content is safe. [Quoted text hidden] 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 SHEET INDEX COVER SHEET PV-1 SITE PLAN PV-2 STRUCTURAL LAYOUT DETAIL PV-3 SINGLE-LINE DIAGRAM PV-4 LABELS PV-5 SPECIFICATION SHEETS SS-6+ GOVERNING CODESVICINITY MAP DESIGN CRITERIA OCCUPANCY TYPE: U RISK CATEGORY: CATEGORY II WIND SPEED: 95 MPH ASCE 7-22 WIND EXPOSURE: B SNOW LOAD: 0 CONSTRUCTION TYPE: VB N PV-1 COVER SHEET GENERAL NOTES SCOPE OF WORK STAMPS & SIGNATURES 1. ALL WORK SHALL COMPLY WITH 2020 NEC, 2022 CEC, 2022 CRC, 2022 CFC, 2022 CBC, 2022 CEES, AND 2022 CGBSC. 2. ALL WORK SHALL BE COMPLETED BY QUALIFIED PERSONNEL. 3. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS' INSTALLATION SPECIFICATIONS AND THE 2022 CEC. 4. PHOTOVOLTAIC PANELS ARE TESTED, LISTED, AND IDENTIFIED WITH A FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703 AND UL 61730. 5. PHOTOVOLTAIC PANELS, RACKING SYSTEM, AND INVERTERS ARE TESTED AND LISTED UNDER UL 2703. 6. INVERTERS ARE LISTED UNDER UL 1741, UL 1741-SA, AND UL 1741-SB. 7. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT SERVICE ENTRANCE. 8. SYSTEM SHALL COMPLY WITH CEC 690.12 REQUIREMENT FOR RAPID SHUTDOWN. 9. SYSTEM SHALL BE INTERCONNECTED ONLY AFTER RECEIVING APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY. 10. EACH PV SYSTEM DISCONNECTING MEANS SHALL BE PERMANENTLY MARKED TO IDENTIFY IT AS A PV SYSTEM DISCONNECT. 11. MEANS SHALL BE PROVIDED TO DISCONNECT EQUIPMENT AND ALL UNGROUNDED DC CONDUCTORS OF THE PV SYSTEM FROM ALL OTHER CONDUCTORS IN A BUILDING OR OTHER STRUCTURE. 12. APPROVED SMOKE ALARMS ARE REQUIRED TO BE INSTALLED PER CRC R314, IN EACH SLEEPING ROOM, OUTSIDE OF EACH SEPARATE SLEEPING ROOM, AND AT EACH STORY INCLUDING HABITABLE BASEMENT. BATTERY-OPERATED ALARMS ARE ACCEPTABLE FOR PHOTOVOLTAIC INSTALLATIONS. 13. APPROVED CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED PER CRC R315, OUTSIDE OF EACH SEPARATE SLEEPING ROOM, AND AT EACH STORY INCLUDING HABITABLE BASEMENT. BATTERY OPERATED DEVICES ARE ACCEPTABLE FOR PHOTOVOLTAIC INSTALLATIONS. 14. APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 365 DAYS FOLLOWING THE DATE OF APPLICATION SHALL AUTOMATICALLY EXPIRE. 15. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS, A SUCCESSFUL INSPECTION IS NOT OBTAINED WITHIN 180 DAYS. PERMITS WHICH HAVE BECOME INVALID SHALL PAY A RENEWAL FEE. INSTALL NEW SOLAR ROOFTOP PHOTOVOLTAIC SYSTEM ON A DETACHED GARAGE AS A SUPPLEMENTAL ELECTRICAL SUPPLY SYSTEM CONNECTED TO THE UTILITY SUPPLY THROUGH THE SERVICE EQUIPMENT. SYSTEM SIZE: 2.600 kW DC / 2.314 kW CEC-AC EQUIPMENT: MODULE: (8) JINKO SOLAR JKM325PP-72 (325W) INVERTER: (8) ENPHASE ENERGY IQ8PLUS-72-2-US (240V) COMBINER BOX: (1) ENPHASE ENERGY X2-IQ-AM1-240-4C (WITH IQ GATEWAY) RACKING: SNAPNRACK ULTRA RAIL UR-40 ATTACHMENT: SNAPNRACK ULTRA RAIL UMBRELLA L FOOT & FLASHING RACKING TYPE: ROOF MOUNT ATTACHMENT TYPE: FLUSH MOUNT BUILDING/ STRUCTURE: DETACHED GARAGE NUMBER OF STORIES: 1 BUILDING SQUARE FOOTAGE: SINGLE FAMILY DWELLING: 1869 SQFT DETACHED GARAGE: 441 SQFT ELECTRICAL: (E) MAIN SERVICE PANEL 200A MAIN / 225A BUS 120/240 VAC SINGLE-PHASE, 3-WIRE END-FED 120% RULE: 70A MAX SOLAR OCPD: 20A 2020 NATIONAL ELECTRICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE www. Loyd W Martin .com Solar Structures Engineering #2023-4435 Structural Only August 8, 2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101116334 Elec# 20180694 Issued 08/24/23 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 SLD PV-4 NOTES SYSTEM SIZE DC RATING 2.600 kW CEC-AC RATING 2.314 kW VOLTAGE DROP % ONE-WAY DISTANCE Imax OHMS/kFT (PER T-8) NOMINAL VOLTAGE VOLTAGE DROP 50 FT 9.68 A 1.98 240 V 9.68 A x [1.98 OHMS/kFT] x [50' x 2/1000'] / 240 V x 100 % = 0.8 % < 2 % >> OK + - + - + - + - (E) 200A MAIN / 225A BUS END-FED 120/240VAC, 1PHASE, 3W ELECTRICAL SERVICE ENTRANCE (N) 20A 2P PV OCPD (E ) L O A D S (E) 200A MAIN OCPD(N) AC DISCONNECT NON-FUSIBLE LOCKABLE SWITCH 30A/240V 2P, NEMA 3R (N) AC COMBINER ENPHASE ENERGY X2-IQ-AM1-240-4C 125A BUS WITH (1) 15A 2P IQ GATEWAY OCPD AND (1) 20A 2P PV OCPD JUNCTION BOX NEMA 4X (8) PV MODULES JINKO SOLAR JKM325PP-72 (8) MICROINVERTERS ENPHASE ENERGY IQ8PLUS-72-2-US (240V) (E) GEC CONDUCTOR SIZING CALCULATIONS Imax (690.8(A)) Icont (690.8(B)(1)) CONDUCTOR TYPE AMPACITY @ 75°C RATING AMBIENT TEMP FACTOR # OF CURRENT-CARRYING CONDUCTORS DERATED AMPACITY @ 90°C RATING (690.8(B)(2)) 1 (8) x 1.21 A = 9.68 A 9.68 A x 1.25 = 12.1 A #12 THWN-2 25 A > Icont >> OK 0.91 1-3 >> 1.00 30 A x 0.91 x 1.00 = 27.3 A > Imax >> OK CONDUIT SCHEDULE CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE MFG Q-CABLES NONE (1) #6 BARE COPPER 2 1/2" EMT OR EQUIVALENT (2) #12 THWN-2 NONE (1) #8 THWN-2 3 1/2" EMT OR EQUIVALENT (2) #12 THWN-2 (1) #12 THWN-2 (1) #8 THWN-2 1. LOWEST AND HIGHEST EXPECTED AMBIENT TEMPERATURE ARE BASED ON ASHRAE DRY BULB EXTREMES (2°C MIN, 39°C MAX). 2. RACEWAYS ARE GREATER THAN 7/8TH INCHES ABOVE ROOF SURFACE. NO TEMPERATURE ADDER REQUIRED. NEC 2020 310.15(B)(2). 3. INVERTER IS COMPLIANT WITH CALIFORNIA RULE 21 UL 1741-SA AND IEEE 1547:2018 UL 1741-SB. 4. THE SYSTEM IS AN UNGROUNDED ARRAY. ALL EQUIPMENT GROUNDING MADE VIA MECHANICAL MEANS OR BY A #8 AWG GROUNDING CONDUCTOR. 5. MODULES, INVERTERS, AND RACKING SYSTEM UTILIZE GROUNDING PER UL 2703. 6. SYSTEM SHALL COMPLY WITH CEC 690.12 REQUIREMENT FOR RAPID SHUTDOWN. 7. PV OCPD AT POINT OF INTERCONNECTION INSTALLED AT OPPOSITE END FROM INPUT FEEDER SHALL COMPLY WITH THE 120% RULE PER NEC 705.12 (B)(3)(2 & 4). AC COMBINER BOX MODEL BRAND ENPHASE ENERGY MODEL NUMBER X2-IQ-AM1-240-4C SYSTEM VOLTAGE 120/240 VAC BUSBAR RATING 125 A MAX OUTPUT CURRENT 65 A MAX OCPD RATING 80 A MICROINVERTER MODEL BRAND ENPHASE ENERGY MODEL NUMBER IQ8PLUS-72-2-US (240V) POWER RATING 290 VA NOM. AC VOLTAGE 240 V MAX OUTPUT CURRENT 1.21 A START VOLTAGE 22 V / 58 V MAX UNITS/BRANCH 13 MAX DC INPUT Isc 25 A PV MODULE MODEL BRAND JINKO SOLAR MODEL NUMBER JKM325PP-72 Pmax 325 W Voc 46.7 V Vmp 37.6 V Isc 9.10 A Imp 8.66 A 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 LABELS PV-5 PLACARD ATTACHED TO MAIN SERVICE PANEL LABELS ATTACHED TO INVERTER/AC COMBINER BOX LABEL ATTACHED TO CONDUITS AT EVERY 10 FEET LABEL ATTACHED TO MAIN SERVICE PANEL LABELS ATTACHED TO AC DISCONNECT LABEL PLACED NEXT TO SOLAR BREAKER INSIDE MAIN SERVICE PANEL LABEL ATTACHED TO JUNCTION BOX NOTES 1. PLACARD SHALL BE PLASTIC WITH MACHINE-ENGRAVED WHITE LETTERING ON RED BACKGROUND, AND ATTACHED TO MAIN SERVICE PANEL WITH POP-RIVETS OR SCREWS. 2. ALL SIGNAGES SHALL BE CLEARLY LABELED WITH WHITE LETTERING ON RED BACKGROUND, ALL CAPITALS, ARIAL OR SIMILAR FONT, 3/8" MINIMUM LETTER HEIGHT, REFLECTIVE, WEATHER RESISTANT MATERIAL. 3. LABEL FOR RAPID SHUTDOWN SWITCH SHALL BE LOCATED NO MORE THAN 3 FEET FROM THE SWITCH. 240 OPERATING VOLTAGE = 240 V / MAX. CURRENT = 20 A WARNING: DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN * DO NOT RELOCATE PV OVERCURRENT DEVICE * 826 LACY ST, SANTA ANA, CA 92701 SOLAR INSTALLER: GRID ALTERNATIVES,GLA CA.PHONE: 310.735.9762 SOLAR MODULES ARE ON THE ROOF (1) MAIN SERVICE PANEL (2) AC DISCONNECT (3) AC COMBINER BOX YOU ARE HERE (1) (2), (3) 9.68 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 LEGEND ARRAY KEY ARRAY - #AZIMUTH PITCH 01 243°10:12 (39°) 02 63°10:12 (39°) ARRAY COVERAGE ARRAYS COVER APPROXIMATELY 27% OF AVAILABLE ROOF SPACE. NOTES LADDER ACCESS POINT 1. ROOF ACCESS AND PATHWAYS ON DETACHED GARAGE ARE EXEMPT PER CFC 1205.2 & CRC R324.6 EXCEPTION 1. 2. LADDER ACCESS POINTS SHALL BE LOCATED AT UNOBSTRUCTED, STRONG POINTS OF BUILDING CONSTRUCTION. 3. WORKSPACE CLEARANCE AROUND ALL ELECTRICAL EQUIPMENT SHALL BE AT LEAST 30" WIDE AND 36" IN FRONT OF EQUIPMENT (NEC 110.26) 4. ALL PV ELECTRICAL EQUIPMENT SHALL BE INSTALLED AT LEAST 36" AWAY FROM ANY EXISTING GAS RISER. 5. CONDUIT SHALL RUN UNDER ROOF EAVE. 1/2" EMT FLUSH-MOUNTED 1" OR GREATER ABOVE ROOFTOP. 6. CONDUIT SHALL BE HIDDEN AND PAINTED TO MATCH WITH BUILDING WALL. 7. SYSTEM SHALL COMPLY WITH CEC 690.12 REQUIREMENT FOR RAPID SHUTDOWN.SITE PLAN SCALE: 1/16" = 1' N PV-2 SITE PLAN PROPERTY LINES 21' 1" 6' 7" 8' 7" 150' 3" 50' (N) ARRAY - 01 (N) ARRAY - 02 (E) MAIN SERVICE PANEL (N) AC COMBINER BOX (N) AC DISCONNECT (STACKED) 21' 6' 9" 37' 8" FIRE SETBACKS EXCEPTION CFC 1205.2 & CRC R324.6 22' LA C Y S T DETACHED GARAGE DRIVEWAY SFD AL L E Y 2.600 kW DC / 2.314 kW CEC-AC SOLAR ELECTRIC SYSTEM MODULE MICROINVERTER COMBINER BOX (1) ENPHASE ENERGY X2-IQ-AM1-240-4C WITH IQ GATEWAY (8) ENPHASE ENERGY IQ8PLUS-72-2-US (240V) (8) JINKO SOLAR JKM325PP-72 www. Loyd W Martin .com Solar Structures Engineering #2023-4435 Structural Only August 8, 2023 NOTE: Engineer of Record assumes that all structural components of the existing building were permitted and met the requirements of the Building Code at the time of construction. Solar Contractor shall field verify that the roof framing is in its existing permitted condition and capable of supporting required live loads. Framing specified on solar plans shall be assumed to be minimum size and spacing, actual framing may be different. 826 N Lacy St 08/30/23 REVISION DESCRIPTION GRID ALTERNATIVES GREATER LOS ANGELES 1662 LONG BEACH AVE, LOS ANGELES, CA 90021 310-735-9762 (P) | 310-388-0288 (F) CLC C-10, C-46 #867533 DESIGNED BY A. HU 07/31/2023 PROJECT INFORMATION CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 APN: 398-041-18 VALUATION: $10,000 STRUCTURAL LAYOUT PV-3 STRUCTURAL INFORMATION # OF STORIES 1 ROOF TYPE COMPOSITION SHINGLES # OF LAYERS 1 FRAME TYPE 2" x 4" ENGINEERED TRUSSES RAFTER/TRUSS SPACING 24" OC MAX UNSUPPORTED RAFTER SPAN 6' - 10" ATTACHMENT TYPE FLUSH MOUNT # OF ATTACHMENTS 16 ARRAY AREA 167.26 SQFT ARRAY WEIGHT 535.44 LBS POINT LOAD 33.47 LBS/ATTACHMENT DISTRIBUTION LOAD 3.2 PSF STRUCTURAL LAYOUT SCALE: NTS N ARRAY - 01 PITCH: 10:12 (39°) AZIMUTH: 243° NOTES: 1. ROOF PENETRATIONS ARE SEALED WITH CHEMLINK M1 AND FLASHINGS. 2. ARRAYS SHALL NOT COVER ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 3. INSTALLERS TO VERIFY RAFTER SIZE AND SPACING. 4. SYSTEM SHALL NOT HAVE ANY HANGING WIRES UNDERNEATH THE PV PANELS.MAX ATTACHMENT SPACING: 4' SCALE: NTS ROOF ATTACHMENT DETAIL SCALE: NTS 39.1" 77.0" 4' 6' 5" 4' 5" 3' 4' 5" 3' 13' 3" 6' 5" 13' 3" (N) 4 - MICROINVERTERS (N) 4 - MICROINVERTERS SNAPNRACK ULTRA RAIL UMBRELLA L FOOT SNAPNRACK ULTRA RAIL UR-40 2" x 4" ENGINEERED TRUSSES @ 24" OC N ARRAY - 02 PITCH: 10:12 (39°) AZIMUTH: 63°3" - 6" SNAPNRACK ULTRA RAIL UR-40 PV MODULE SNAPNRACK COMP FLASHING SNAPNRACK ULTRA RAIL UMBRELLA L FOOT (1) 5/16" x 4" SS UMBRELLA LAG SCREW 2-1/2" MINIMUM EMBEDMENT INTO FRAMING 2" x 4" ENGINEERED TRUSSES @ 24" OC www. Loyd W Martin .com Solar Structures Engineering #2023-4435 Structural Only August 8, 2023 826 N Lacy St 08/30/23 www.jinkosolar.com PowerWarranty PID-FREE 2400 Pa 5400 Pa RESISTANT LOW LIGHT CLIMATE DURABILITY KEY FEATURES Through the internal nano-level reflection technology to improve the power output, Polycrystalline 72-cell module achieves a power output up to 325Wp LINEAR PERFORMANCE WARRANTY JKM325PP-72(Plus) Positive power tolerance of 0/+3% 310-325Watt POLY CRYSTALLINE MODULE ISO9001:2008 ISO14001:2004 OHSAS18001 certified factory. IEC61215 IEC61730 certified products. Extreme high efficiency module: Through the unique high reliability encapsulating technology to make sure the module possess anti-PID characteristics under high temperature and humidity for a long time, Have passed anti-PID test 60 /85% RH condition for 1000h Anti-PID Guarantee: Advanced glass and surface texturing allow for excellent performance in low-light environments. Low-light Performance: Certified to withstand: wind load (2400 Pascal) and snow load (5400 Pascal). Severe Weather Resilience: 100% 97.5% 90% 80.7%Gu a r a n t e e d P o w e r P e r f o r m a n c e New linear performance warranty High salt mist and ammonia resistance certified by TUV NORD. Durability against extreme environmental conditions: Improved temperature coefficient decreases power loss during high temperatures. Temperature Coefficient: Plus 826 N Lacy St 08/30/23 Engineering Drawings SPECIFICATIONS Mechanical Characteristics Electrical Performance & Temperature Dependence Packaging Configuration 35 404.5 14 95.5 70 70 3 8 19 5 6 992 40 10 0 86 0 13 6 0 L 942 Installing Holes Label Junction box Cathode - + Anode Connector Grounding Holes A A Current-Voltage & Power-Voltage Curves (310W) Temperature Dependence of Isc,Voc,Pmax Isc Voc Pmax 2-Ø4 ² 5 10 15 20 25 30 35 0 40 45 0 1 2 3 4 5 6 7 8 9 10 0 45 90 135 180 225 270 315 -40 1000VDC (IEC) 15A 0~+3% -0.40%/ -0.30%/ 0.06%/ 45±2 JKM310PP(Plus) 310Wp 37.0V 8.38A 45.9V 8.96A 15.98% 231Wp 6.81A 33.9V 42.7V 7.26A JKM315PP(Plus) 315Wp 37.2V 8.48A 46.2V 9.01A 16.23% 235Wp 6.84A 34.3V 43.2V 7.29A ~+85 JKM320PP(Plus) 320Wp 37.4V 8.56A 46.4V 9.05A 16.49% 238Wp 6.86A 34.7V 43.7V 7.30A JKM325PP(Plus) 325Wp 37.6V 8.66A 46.7V 9.10A 16.75% 242Wp 6.91A 35.0V 44.0V 7.34A 826 N Lacy St 08/30/23 826 N Lacy St 08/30/23 826 N Lacy St 08/30/23 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery • Supports Wi-Fi, Ethernet, or cellular connectivity • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) 826 N Lacy St 08/30/23 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage) 64A Max. fuse/circuit rating (output) Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input) IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD) Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Wire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors • 60A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Altitude INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C 826 N Lacy St 08/30/23 mwatkins Solar Mounting Solutions B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in Iyy 0.132 in Sx (TOP) 0.150 in³ Sx (BOT) 0.158 in³ Sy (LEFT) 0.175 in³ Sy (RIGHT) 0.175 in³ 9-21 826 N Lacy St 08/30/23 MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 802 UP, 1333 DOWN, 356 SIDE 2005 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 0.79 - 1.03 REVISION: mwatkins C PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA RAIL UMBRELLA L FOOT, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK232-01375, 232-01376, 232-0137713 3 1 2 9-21 826 N Lacy St 08/30/23 ALL DIMENSIONS IN INCHES REVISION: mwatkins C 11.75 3.25 8.75 .45 6.75 4.20 .30 1.50 .30 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM 232-01377 COMP FLASHING, 9" X 12", BLACK GALVALUME .35 1.00 105° 1.00 SLOT .38 1.62 2.78 1.78 1.501.80 3.25 1.37 .30 .25 9-21 826 N Lacy St 08/30/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2 -1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 826 N Lacy St 08/30/23 Structural Calculations for a Roof Mounted Solar Photovoltaic System for: Habitat for Humanity OC 826 N Lacy St Santa Ana, CA 92701 Applicable Codes: 2022 California Building Code, 2022 California Electric Code, 2022 California Mechanical Code, American Society of Civil Engineers Standard ASCE 7-16 Minimum Design Loads for Buildings and Other Structures, American Wood Council 2018 National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adopted by reference or enacted by law. Assumed Design Parameters: The existing structure has been built under a building permit and is in its original condition. The existing roof structure is capable of its code required live load and the ability of the roof structure to support live loads has not been substantially reduced by the age of the structure, termites or mold, or unauthorized modifications to the existing structure. Solar Energy Contractor shall make an inspection of the existing roof framing system prior to installation of the roof mounted solar energy system to verify that the existing roof is capable of supporting minimum roof live loads. Assumed Design Parameters: All 2x members are grade Douglas Fir #2 or better All 4X members are grade Douglas Fir #1 or better All Roof Connectors are Simpson Strong-Tie or Equal All Concrete Foundations are f'c = 2500 psi or stronger Sht # 1 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Original Structure was built to the Type-V Wood Framed Standards of the Applicable Building Code at the time of Construction. 826 N Lacy St 08/30/23 Note to Building Official: Based upon a review of the proposed plans I am confident that the existing roof framing system is capable of safely supporting the additional loads caused by the new solar photovoltaic energy system. The contractor shall field verify that the existing roof structure is in its original permited condition and verify that it can support the normal code required roof live loads. Attached in this package are several calculations showing that the roof members can support the additional weight of the solar array. Furthermore, an analysis of the solar array's support for wind forces and a seismic analysis of the existing structure are also included. Check Existing 2X4 Roof Trusses @ 24" O.C.: w = 30 psf x 2 ft. = 60 plf Total load on trusses = 60 plf x 14.3 ft. = 858 lbs Sht # 2 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com 5 :'/// 5 14.3' 826 N Lacy St 08/30/23 Check Existing 2X4 Roof Trusses @ 24" O.C.: Snow Load = 0 psf Dead Load = 14 psf Live Load = 16 psf WDL + LL = 30 psf x 2 ft. = 60 plf WDL = 14 psf x 2 ft. = 28 plf w = 30 psf x 2 ft. = 60 plf Total load on trusses = ( 60 plf x 7.9 ft ) + ( 28 plf x 6.4 ft ) + ( 4' x 3.2' x 3 psf x 2 ) = 730 lbs < 858 lbs OK OK. Per 2022 California Existing Building Code Section 503.3 Alterations Check attachment of Support to Existing Structure for Wind Uplift CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2. NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA: FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT BE LESS THAN ONE-THIRD ITS LENGTH. EFFECTIVE AREA = 15 SQ FT Sht # 3 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com % CHANGE =730 lbs - 858 lbs x 100 = -14.9% < 5% OK858 lbs Z //Z '/ 55   3 3 826 N Lacy St 08/30/23 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Tributary Area to Each Solar Mount = 4 ft. x 3.2 ft. = 12.8 sq. ft. ( Max ) Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C): p = q h (GC p )(γE )(γ a )Eq'n 29.4-7 ASCE 7-16 q h = 0.00256 K z K zt K d K e V2 Eq'n 26.10-1 ASCE 7-16 Note: K z = velocity pressure coefficient Section 29.10.1 ASCE 7-16 K z = 0.9 (Exposure C, Height = 20 ft or less) K zt = Topographical Factor = 1.0 K d = Wind Directionality Factor = 0.85 K e = Ground Elevation Factor = 1.0 V = 130 mph ; VASB = 101 mph q h = 0.00256 (0.9) (1.0) (0.85) (1.0) (101)² q h = 19.98 psf GC p = -2.0 (Zone 2 ; Effective Area = 15 sq. ft. ) γE = Exposure Factor = 1.5 γa = Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4-8 ASCE 7-16 p = q h (GC p )( γE )( γa ) p = 19.98 psf (-2.0) (1.5) (0.7) = 42 psf Sht # 4 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com 826 N Lacy St 08/30/23 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Nominal (Unfactored) Uplift at each support = 42 psf x 12.8 sq. ft. = 537.6 lbs Note: Section 2.4.1 of ASCE 7-16, Basic Load Combinations for Allowable Stress Design. Note: Applicable Load Combination #5 (D + 0.6W) Design (Factored) Uplift at each support = 0.6 x 537.6 lbs = 323 lbs Load per lag screw = 323 lbs / 1 = 323 lbs Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below according to the 2018 NDS. W ' = W x Cd x Ct Table 10.3.1 2018 NDS where W = 266 lbs / in. of embedment per Table 12.2a Cd = 1.6 per Table 2.3.2 of 2018 NDS Ct = 1.0 per Table 2.3.3 of 2018 NDS W' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 323 lbs OK Sht # 5 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Use Support connected to 2x Min. Roof Member w/ (1) 5/16" x 4" lag screws per connection minimum. 826 N Lacy St 08/30/23 Check Seismic load due to added dead load of photovoltaic system. Determine Seismic Weight of Existing Building: Effective Existing Seismic Weight Area of (E) Building = Approximately 600 Sq. ft Approximate Effective = 600 sq. ft. x 15 psf ave. = 9,000 LBS Seismic Weight DETERMINE BASE SHEAR V = Cs W EQ'N 12.8-1 ASCE 7-16 EQ'N 12.8-2 ASCE 7-16 R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1 R = 6.5 WOOD SHEAR WALLS Ie = 1.0 IMPORTANCE FACTOR SDS = 2/3 x SMS SMS = FA x SS SMS = 1.2 x 1.5 = 1.8 SDS = 2/3 x 1.8 = 1.2 Cs == 0.185 EQ'N 12.8-2 ASCE 7-16 Sht # 6 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Cs = SDS R Ie SDS R Ie 826 N Lacy St 08/30/23 EXISTING BASE SHEAR V = 0.185 x 9,000 LBS = 1,665 LBS DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING SEISMIC = 9,000 LBS WEIGHT NEW SOLAR ARRAY = 3 PSF x 8 PANELS x 6.4' x 3.3' = 507 LBS NEW SEISMIC = 9,000 LBS + 507 LBS = 9,507 LBS WEIGHT THEREFORE NEW BASE SHEAR: V = 0.185 x 9,507 = 1,759 LBS EQ'N 12.8-1 ASCE 7-16 OK. PER ASCE 7-16 SECTION 11B.4 ALTERATIONS EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT FROM ANALYSIS SINCE NEW SEISMIC FORCE IS LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE Sht # 7 of 7 2023-4435 Grid Alt LA Habitat for Humanity OC August 8, 2023 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 "Alterations may be made to any structure without requiring the existing structure to comply with this standard, provided that the alterations comply with the requirements for a new structure. Alterations that increase the seismic force in any existing structural element by more than 10% or decrease the design strength of any existing structural element to resist seismic forces by more than 10% shall not be permitted unless the entire seismic force-resisting system is determined to comply with this standard for a new structure." End of Calculations Email: loydwmartin@gmail.com www.loydwmartin.com % CHANGE =1,759 LBS - 1,665 LBS x 100 = 5.6 % < 10 % OK 1,665 LBS 826 N Lacy St 08/30/23 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 826 N Lacy St 08/30/23 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 826 N Lacy St 08/30/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan 826 N Lacy St 08/30/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 826 N Lacy St 08/30/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram 826 N Lacy St 08/30/23 23/08/2023, 10:51 GRID Alternatives Mail - Letter of approval for Lacy Street projects https://mail.google.com/mail/u/0/?ik=679fea25c8&view=pt&search=all&permmsgid=msg-f:1774673989055701694&simpl=msg-f:1774673989055701694 1/1 Freida Galindo <fgalindo@gridalternatives.org> Letter of approval for Lacy Street projects Allan Cabrera <allan@habitatoc.org> Sat, Aug 19, 2023 at 9:03 AM To: Malcolm Vivian <mvivian@gridalternatives.org> Cc: Freida Galindo <fgalindo@gridalternatives.org>, Raymond Harrison <raymond@habitatoc.org>, Rita Ross <rita@habitatoc.org>, Mike Speck <mikes@habitatoc.org> Hi Malcolm, Apologies for the delayed response. Please see below. Habitat for Humanity authorizes GRID alternaƟves to install rooŌop solar at the following addresses: 826 North Lacy Street, Santa Ana 92701 830 North Lacy Street, Santa Ana 92701 Thank you, From: Malcolm Vivian <mvivian@gridalternatives.org> Sent: Friday, August 18, 2023 4:59 PM To: Lauren Hahn <lauren@habitatoc.org> Cc: Freida Galindo <fgalindo@gridalternatives.org>; Allan Cabrera <allan@habitatoc.org> Subject: Re: LeƩer of approval for Lacy Street projects CAUTION: This email originated from outside of the organizaƟon. Do not click links or open aƩachments unless you recognize the sender and know the content is safe. [Quoted text hidden] 826 N Lacy St 08/30/23