HomeMy WebLinkAbout2300 N Tustin Ave - REV1 - PlanOCCUPANCY LOAD PER CBC
ROOM/SPACE AREA
(SQ. FT.)
OCC. LOAD
FACTOR
KITCHEN OCC.
DINING OCC.
QUEUING OCC.
STORAGE OCC.
RESTROOMS, CIRCULATION, ETC.OCC.
OFFICE
TOTAL OCCUPANTS OCC.
2022 CALIFORNIA BUILDING CODE - CBC
2022 CALIFORNIA PLUMBING CODE - CPC
2022 CALIFORNIA MECHANICAL CODE - CMC
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA FIRE CODE
NFPA 54-2022 CODE
2022 GREEN BUILDING CODE & 2022 ENERGY CODE
2022 CALIFORNIA BUILDING CODE - CBC (CHAPTER 11B)
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
CITY OF SANTA ANA MUNICIPAL CODE
IMAGE UPGRADE TO EXTERIOR, NEW SIGNS UNDER SEPARATE PERMIT. NEW
PAINT AND DECORATIVE ROOF PARAPETS. NEW ARCHITECTURAL FEATURE.
INTERIOR TI TO INCLUDE NEW HALLWAY, NEW DRIVE-THRU AND SERVICE
COUNTERS, SEATING UPGRADE BY VENDOR AND NEW EXTERIOR LIGHTING.
ZONING C5 ARTERIAL COMMERCIAL
APN 396-261-36
OCCUPANCY CLASSIFICATION A-2
CONSTRUCTION TYPE V-B
FIRE SPRINKLER SYSTEM NOT SPRINKLERED
EXISTING BUILDING AREA 1,886 SQ. FT.
PROPOSED ADDITION 210 SQ. FT.
TOTAL NEW BUILDING 2,096 SQ. FT.
G001 COVER SHEET
G002 ACCESSIBILITY DETAILS
A002 PROPOSED SITE PLAN
A003 SITE PLAN DETAILS
A005 EXISTING FLOOR PLAN
A010 DEMOLITION PLAN
A101 FLOOR PLAN
A121 REFLECTED CEILING PLAN
A131 ROOF PLAN
A132 ROOF DETAILS
A201 EXTERIOR ELEVATIONS
A201C COLORED EXTERIOR ELEVATIONS
A202 EXTERIOR ELEVATIONS
A202C COLORED EXTERIOR ELEVATIONS
A601 DOOR, WINDOW, FINISH SCHEDULE AND DETAILS
A601.1 MANF FLOOR SPEC
A603 DETAILS
A604 DETAILS
SCOPE OF WORK
APPLICABLE CODES SHEET INDEX
SHEET DESCRIPTIONTR
A
D
E
AR
C
H
I
T
E
C
T
U
R
A
L
OWNER:
DEL TACO
25521 COMMERCE CENTRE DR.,
SUITE 200
LAKE FOREST, CA 92630
CONTACT: KORI SEKI - DIRECTOR OF
DESIGN & ARCHITECTURE
EMAIL: KSEKI@DELTACO.COM
C: 949-706-4727
ARCHITECT:
PAUL DEPPE
ARMET DAVIS NEWLOVE
1330 OLYMPIC BLVD SANTA MONICA,
CA 90404
T: 310.452.5533 EXT. 203
C: 310.503.7778
EMAIL: DEPPE@ ADNARCH.COM
ELECTRICAL/PLUMBING ENGINEER:
AMOS SLUTZKY
AMELECT, INC.
1330 OLYMPIC BLVD. SANTA MONICA,
CA 90404
EMAIL: AMELECT@IX.NETCOM.COM
STRUCTURAL ENGINEER:
RICK TAYLOR
HTK STRUCTURAL ENGINEERS, LLP
14288 DANIELSON STREET, SUITE 200
POWAY, CA 920604
T: 858-679-8989 EXT. 24
EMAIL: RICKY@HTKSE.COM
PROJECT DIRECTORY
OCCUPANT LOAD
PROJECT SUMMARY:
VICINITY MAP
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
LA
N
D
S
C
A
P
E
OCCUPANT LOAD SHALL BE POSTED IN THE ASSEMBLY ROOM
EXIT REQUIREMENTS: < 50 OCCUPANTS 1 EXITS REQUIRED / 2 PROVIDED
> 50 OCCUPANTS 2 EXITS REQUIRED / 2 PROVIDED
MINIMUM PLUMBING FIXTURE CALCULATION:
BASED ON TOTAL OCC. LOAD: DINING AREA / 30 = 625 SF / 30 = 21 OCC.
MINIMUM PLUMBING FIXTURES FOR CPC 422.1 TABLE A:
1 PER 50 MALES REQUIRED / 1 WATER CLOSET PROVIDED - EXISTING
1 PER 50 FEMALES REQUIRED / 1 WATER CLOSET PROVIDED - EXISTING
E001 SYMBOLS LIST, GENERAL NOTES AND ABBREVIATIONS
E101 LIGHTING PLAN
E201 ELECTRICAL POWER PLAN
E302 ELECTRICAL PANEL SCHEDULES
E501 INTERIOR ENERGY COMPLIANCE FORMS
E502 INTERIOR ENERGY COMPLIANCE FORMS
E503 EXTERIOR ENERGY COMPLIANCE FORMS
E504 EXTERIOR ENERGY COMPLIANCE FORMS
EL
E
C
T
R
I
C
A
L
P001 PLUMBING NOTES, SCHEDULES, LEGEND AND ABBREVIATIONS
P002 PLUMBING SPECIFICATIONS
P101 PLUMBING FLOOR PLAN
P201 PLUMBING SITE PLAN
PL
U
M
B
I
N
G
GEOTECHNICAL ADDENDUM LETTER
ENGINEER:
GEO ENVIRONMENTAL RESOURCES INC
2511 WEST LA PALMA AVE.,
SUITE E
ANAHEIM, CA, 92801
CONTACT: ALEXANDER A. RASTEGAR
PROJECT ENGINEER
EMAIL: ALEXRASTEGAR@YAHOO.COM
C: 714-995-9001
S1 FOUNDATIOIN PLAN AND FRAMING DETAILS
S2 STRUCTURAL NOTES AND DETAILS
ST
R
U
C
T
.
L100 PLANTING PLAN
L101 PLANTING NOTES
L200 IRRIGATION PLANS
L201 IRRIGATION NOTES
L300 DETAILS
L301 DETAILS
L400 SPECIFICATIONS
L401 SPECIFICATIONS
L402 SPECIFICATIONS
Signed On: 6-14-24
Bldg# 101117751-52
Plmg# 30146715
APPROVALS:
PLNG - CSantana
BLDG - CSG Consultants
PLMG - CSG Consultants
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
TYP. STD. LAYOUT OF ACCESSIBLE TOLIET
UNOBSTRUCTTED SIDE REACH
UNOBSTRUCTED FORWARD REACH
·
·
·
·
INTERNATIONAL SYM. OF ACCESSIBILITY
OBSTRUCTED HIGH SIDE REACH
OBSTRUCTED HIGH FORWARD REACH
STD. VISUAL/TACTILE SIGNAGE
SINK AND URINAL CLEARANCES STD. LAYOUT OF ACCESSIBLE LAVATORY
STD. HEIGHT REQUIREMENTS
STD. LAYOUT OF ACCESSIBLE URINAL
GRAB BAR MOUNTING
ALL GENDER RESTROOM SYMBOL
EXIT
·
·
·
·
EXIT
TOE & KNEE CLEARANCE REQUIREMENT
@ DINING SURFACES
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed On: 6-14-24
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
E
S
A
N
T
A
C
L
A
R
A
A
V
E
N TUSTIN AVE
PROPOSED SITE PLAN
KEY NOTES
PARKING LEGEND
PARKING ANALYSIS
EV
CAPABLE
EV
CAPABLE
EV
CA
P
A
B
L
E
EV
CA
P
A
B
L
E
NO PARKING
ENLARGED REAR DOORS
A - REAR HALLWAY DOOR
B - REAR SERVICE DOOR
VAN
42
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
PARKING ONLY
MINIMUM FINE $250
VAN
ACCESSIBLE
UNAUTHORIZED PARKING
INT. SYM. OF ACCESSIBILITY
ACCESSIBLE PARKING SIGN
DETECTABLE WARNING
TRASH ENCLOSURE FLOOR PLAN TRASH ENCLOSURE ROOF PLAN
EXISTING TRASH ENCLOSURE PARKING LOT STRIPPING
TYP. ACCESSIBLE PARKING STALLACCESSIBLE CURB RAMPCONCRETE CURB AT PLANTERGUARD RAIL @ RAMP
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
EXISTING FLOOR PLAN
STORAGE
AREA
KITCHEN
DRIVE
THRU
SERVICE
AREA
OFFICE
AREA
ALL GENDER
RESTROOM
ALL GENDER
RESTROOM
STORAGE
AREA
DINING
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
DEMOLITION PLAN
WALL LEGEND
DEMOLITION GENERAL NOTES
MINOR WORK DONE IN KITCHEN
AREA. PROTECT KITCHEN
EQUIPMENT DURING
CONSTRUCTION. ALL KITCHEN
EQUIPMENT TO REMAIN.
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
ITEM
NO
QTY.EQUIPMENT CATEGORY MARK
1
1
1 (N) ICE DISPENSER ON BEVERAGE MACHINE
(N) HAND SINK1
(N) MAGNETIC MENU BOARD1
(N) BEVERAGE BAR
(N) BEVERAGE MACHINE
1
1
(E) POS3
1 (E) 4'-0" GRILL
(E) HEAVY FRYERS2
1 (E) 3 COMP SINK
(E) WALK IN COOLER1
(E) BAG IN THE BOX AND (1) RACK #401
1 (E) CO2 TANK
(E) FRY FREEZER1
(E) WATER HEATER1
2 (E) STOCK POT RANGE 2 BURNER
(E) MOP SINK1
(N) FRY DUMP STATION1
1 (E) MANAGER DESK
(E) FWE HEATED HOLDING CABINET1
(E) ELECT. PANEL1
(E) SHAKE MACHINE
1
(E) COFFEE/TEA BREWER1
7 (E) STORAGE RACKS
1
(E) SANDWICH PREP. TABLE
(MAFG.: MANITOWOC, MODEL: IB-1094YC)
((E) 75 GAL. W/75,000 KBTU RATING)
(MFR.: TRUE, MODEL: TSSU-27-08-HC)
1
EQUIPMENT SCHEDULE
(E) PREP SINK
(MFR.: JOHN BOOS , MODEL: 1B18244-2D18 )
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
(E) BEV. MACHINE W/ TOP ICE DISPENSER
RELOCATED
(N) TABLE BY AVANTI
1
(N) DRIVE-THRU COUNTER 8'-6" X 3'-0"
41 1 (N) SERVICE COUNTER 9'-7-1/2" X 2'-6"
REPLACE (E)
REPLACE (E)
REPLACE (E)
REPLACE (E)
1 (E) SS TABLE W/ WHEELS
1
1
(E) FLOOR SINK 7
2
1 (E) FILING CABINET
1
1 (E) ICE MACHINE
(E) L-TACO BAR LINE
(E) HAND SINK1
REPLACE (E)
RELOCATED
REPLACE (E)
(1) RELOCATE
RELOCATED F.S.
(N) FLOOR SINK
RELOCATED1
1 (N) PREFAB. WALK-IN FREEZER
(MFR. Kolpak, CUSTOM)
2 (E) AIR CURTAINS RELOCATED
1 (E) AIR CURTAIN
1 (N) STORAGE RACK42
5 (N) WIRE SHELVING FOR WIC42
1- FOR NEW WALK-IN CONDENSATE
2- FOR FUTURE COMBI OVEN
RELOCATE F.S. @ SERV. COUNTER
TO D.T. COUNTER SINK #36.
(N) EMPLOYEE LOCKER143
30X
4
8
24x42
SS5'-
0
"
24x45
SS
CH
5'-
0
"
24x45
SS
24x45
SS
LB
B
5
4
LB
B
7
2
LB
B
7
2
LB
B
5
4
24x24
SS
24x42
SS
CH
24x42
SS
LBB42
LBB42
LBB42
BS
22x27
LABS
24x42
SS
24x42
SS
LBB42
LBB42
LBB42
CH
CH
CH
CH
CH
CH
CH
24x24
SS
24x24
SS
24x24
SS
24x42
SS
CHCH
WR
1
WR2
(E)
(E)
(E)(E)
(E)(E)
(E)
1
2
19
16
40
4040
22
13
12
34
27
40 40 40
26
23
1425
3 3638 41
246
21
18
28
15
8
17
20
30
4
5 32
7
5 53937
2911
1111
11
11
11 11
10
9
9
31
31
33
42 42
42 42
42
1836-5
42
(N)
(N)
(A)
43
FLOOR PLAN
GENERAL NOTES
KEY NOTES
STORAGE
AREA
KITCHEN
SERVICE
AREA
OFFICE
AREA
ALL GENDER
RESTROOM
ACC. ALL
GENDER
RESTROOM
STORAGE
AREA
WALL LEGEND
1.SEE SHEET A601 "ROOM FINISH
SCHEDULE" FOR FINISHES.
HALLWAY
DINING
DRIVE-
THRU
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed On: 6-14-24
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
REFLECTED CEILING PLAN
GENERAL NOTES
CEILING PLAN LEGEND
INT. MATERIAL/FINISH SCHEDULE
WALL TO (E) OVERHANG
WALL @ (E) OVERHANG - TYP.
KEY NOTES
SPECIFICATIONSSYMBOLMK.
A2
B1
B3
H2
EM1
EX1
B1X
A3
1.SEE SHEET A601 "ROOM FINISH SCHEDULE" FOR
WALL FINISHES
G1
R1
DRIVE
THRU
KITCHEN
OFFICE
AREA
STORAGE
AREA
DINNING
(E) ACC. ALL GENDER
RESTROOM
(E) ACC. ALL GENDER
RESTROOM
SERVICE
AREA
R2
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
ROOF PLAN
G.C. SCOPE NOTES
ROOF PLAN NOTES
KEY NOTES
LIGHTING LEGEND
J3
42
42
EXISTING ROOFING AND
EQUIPMENT IS LOCATED
WITHIN ROOF STRUCTURE
AND THEY ARE TO REMAIN
UNCHANGED.
NO WORK DONE IN THIS
AREA.
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
PARAPET FRAMING @ MANSARD
ARCH. FEATURE FRAMING @ MANSARD
SECTION THROUGH HALLWAY
BASE FLASHING
TYPICAL CRICKET
PARAPET FLASHING
PARAPETWEEP SCREED
A B
NOT USED NOT USED
NOT USED
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
GENERAL NOTES
DEMOLITION / FINISH NOTES
NORTH ELEVATION
GENERAL NOTES
DEMOLITION / FINISH NOTES
EAST ELEVATION
2300
EXT. MATERIAL/FINISH SCHEDULEEXT. MATERIAL/FINISH SCHEDULE
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
GENERAL NOTES
DEMOLITION / FINISH NOTES
WEST ELEVATION
GENERAL NOTES
DEMOLITION / FINISH NOTES
SOUTH ELEVATION
EXT. MATERIAL/FINISH SCHEDULEEXT. MATERIAL/FINISH SCHEDULE
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
F-4 FLOOR TO BE APPLIED
PER THESE SPECS AND
PROVIDED MANF. SECTION
099726 CEMENTITIOUS
COATING SPECS.
DOOR SCHEDULEINT. MATERIAL/FINISH SCHEDULE
ACCESSIBLE SIGNAGE
ROOM FINISH SCHEDULE
DOOR TYPES
HARDWARE SCHEDULEDOOR NOTES
KEY PLAN
WINDOW SCHEDULE WINDOW TYPES
NOT
USE
D
DINING
KITCHEN
ACC. R.R.
R.R.
HALL-
WAY
SERVICE
COUNTER
DRIVE
THRU
NOT
USE
D NOT
USE
D
SELF
SERVE
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
(N) FOOTING TO (E) FOOTING@ HALLWAY
DESIGN NOTES:
WIND SEISMIC
DESIGN LOADS
FOUNDATION NOTES
GENERAL NOTES
WOOD NOTES (CBC CHAPTER 23)
COLD-FORMED STEEL FRAMING (CBC CHAPTER 22)
TYPICAL INTERIOR WALL SECTIONTYPICAL CONNECTION DETAILS
FOUNDATION PLAN
HALLWAY
DINING
KITCHEN
(E)
RESTROOM
SERVICE
AREA
DRIVE
THRU
ACC.
RESTROOM
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
SIGNED 2-25-2024
SIGNED 2-25-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
ALUM. WINDOW HEADER/JAMB
ALUM. WINDOW SILL
INTERIOR DOOR SILL
INTERIOR DOOR HEADER/JAMB
INTERIOR EXTERIOR
2
1
INTERIOR EXTERIOR
ALUM. DOOR SILL
ALUM. DOOR HEADER/JAMB
ALUM. STOREFRONT SILLINTERIOR DOOR SILL
INTERIOR DOOR HEADER/JAMB
NOT USED
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
OBSTRUCTED HIGH REACH SIDEACCESSIBLE SEATING
NOT USED
ENLARGED ACCESSIBLE RESTROOM
TYP. BASE DETAIL
EXPANSION JOINT
SERVICE AND D.T COUNTER ELEVATIONS
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
(N) FOOTING TO (E) FOOTING@ HALLWAY
FOUNDATION PLAN
HALLWAY
DINING
KITCHEN
(E)
RESTROOM
SERVICE
AREA
DRIVE
THRU
ACC.
RESTROOM
PARAPET FRAMING @ MANSARD
ARCH. FEATURE FRAMING @ MANSARD
SECTION THROUGH HALLWAY
NOT USED
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
CHECK IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN
CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE
INFORMATION GIVEN IN THE CONTRACT DOCUMENTS.
GER INC.
NO EXCEPTION TAKEN
BY DATE
APPROVED AS NOTED
REJECTED
REVISE AND RESUBMIT
FOR INFORMATION ONLY
4
Alexander A. Rastegar 5/06/24
Signed: 5-16-2024
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
TYPICAL INTERIOR WALL SECTION
TYPICAL CONNECTION DETAILS
STRUCTURAL NOTES
DESIGN NOTES:
WIND SEISMIC
DESIGN LOADS
FOUNDATION NOTES
GENERAL NOTES
WOOD NOTES (CBC CHAPTER 23)
COLD-FORMED STEEL FRAMING (CBC CHAPTER 22)
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
Signed: 5-16-2024
Signed: 5-16-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
Signed: 5-15-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
Signed: 5-15-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
Signed: 5-15-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
WALLS LAYOUT CEILINGS LAYOUT
FLOORS LAYOUT
WALK - IN SPECIFICATIONS
L
U
}
1. SUBMITTAL DRAWING NOT INTENDED FOR INSTALLATION.
AS-BUILT DRAWING FOR INSTALLATION WILL BE AVAILABLE AFTER ORDER IS P LACED. HARD COPY OF AS-BUILT DRAWING WILL BE IN HARDWARE
BOX WITH WALK-IN SHIPMENT TO JOBSITE. ALL AS-BUILT DRAWINGS SHOW PART NUMBERS AND ID LABELS ON PLAN VIEWS.
2. ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE
3. PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS
4. ALLOW 2" MINIMUM CLEARANCE WITH AIRFLOW OF 5 CFM PER 100 SQ FT AROUND ENTIRE PANEL SURFACES. INDOOR WALK-INS REQUIRE A
75°F AMBIENT AND 55% RELATIVE HUMIDITY OR LESS AROUND THE EXTERIOR OF THE WALK-IN.
5. GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MANUAL FOR FLOOR DETAIL INFORMATION
6. QUARRY TILE OR CONCRETE FLOOR APPLICATIONS: METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE
CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS. IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED.
SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS
7. PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS
8. WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE
9. IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24" OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES
10. FLOOR, CURB, AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY. THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE
DESIGN OR PREPARATION OF THE INSULATED FLOOR, SUB-SLAB OR CURBS, WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED
ENGINEER. ALL FOOTINGS, FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR ARCHITECT.
11. THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS: FLAME SPREAD RATING: 20; SMOKE
DEVELOPED RATING: 450; FLASH IGNITION TEMPERATURE RATING: 915°f; SPONTANEOUS IGNITION TEMPERATURE RATING: 950°f.
12. R-VALUES MEET DOE REQUIREMENTS AND ARE ASTM C518 TESTED. COOLER R-VALUES ARE R-29 FOR 4" THICK, R-36 FOR 5" THICK, AND
R-44 FOR 6" THICK PANELS. FREEZER R-VALUES ARE R-32 FOR 4" THICK, R-40 FOR 5" THICK, R-48 FOR 6" THICK PANELS, AND R-29 FOR 4" FLOORS.
13. FLOORS NOT DESIGNED FOR WET MOPPING, PALLET JACKS, OR FORKLIFT TRAFFIC.
! ATTENTION
DATE:_____________ BY:_____________________________
YOU MUST REVIEW ALL NOTES, DETAILS, DIMENSIONS,
FINISHES, DOORS SIZES, LOCATIONS AND SWINGS
APPROVAL- NO CHANGE REQUIRED, MANUFACTURE AS
DRAWN.
APPROVED AS NOTED - MAKE REQUIRED CHANGES AND
MANUFACTURE AS DRAWN.
NOT APPROVED- DESIGN CHANGES REQUIRE DRAWING
REVISION AND RESUBMISSION.
FOR APPROVAL
SMOOTH FINISH DISCLAIMER
Panels with non-textured and/or no-profile panel finishes (smooth finishes) on the
exterior and interior faces may exhibit “oil canning" and flatness imperfections on the
surface. Our standard panels have a stucco embossed texture on both faces that helps to
reduce oil canning and any other irregularities in the exposed surface. Please be aware
of this potential situation in your specification process. Such “oil canning” and flatness
issues are typical and are not covered under standard warranties.
D
AT
E:
QUOTE
R
EVISI
ON
D
EL TAC
O - STANTON
STANTON,CA 90680 USA
A
VAN
TI RES
TAUR
ANT
S
OLUTIO
NS
AD-1 of 2
DR
AWING #:
2915 Tennes
see A
ven
ue Nor
th, Par
sons
, T
N 3
8363 (731) 847
-636
1 *(8
00) 826-
7036*
0
4/20
/
20
21
DATE
:
CHECK
B
Y:
D
ATE
:
KAD
D
RAW
N B
Y:
SHEET #
A
188429R
1
0
01
®
UNI
T #:
O
RDER #:
}NSF
Kolpak and Harford walk-ins are compliant with UL standards.
• Door panels are UL471, UL file listing E46140.
• Standard Evaporator coils are UL412.
•Condensing Units are UL1995.
U NOTICE:L}
F01 -
FREEZER :
W/FLOOR
9' - 0 1/4" O.A. HEIGHT
8' - 4 5/8" I.D.
PANELS
FOAMED IN PLACE URETHANE FOAM 4"
EXTERIOR FINISH
WALL: GALVALUME - EMBOSSED 26 GA
TOP: GALVALUME - EMBOSSED 26 GA
FLOOR: GALVALUME - EMBOSSED 26 GA
INTERIOR FINISH
WALL: ALUMINUM - EMBOSSED WHITE .040
TOP: ALUMINUM - EMBOSSED WHITE .040
FLOOR TYPE
F01 FREEZER :
STANDARD 1000# ERA
ALUMINUM - SMOOTH ALUMINUM .100
WALK-IN ACCESSORIES
(50) COVE BASE, ALUMINUM EMBOSSED WHITE .040 1.25 X 4.25
(1) LIGHT FIXTURE - KASON 1810LC LED 48IN 120/230V 50/60HZ (DIODE STRIPS)
(7) TIE DOWN ANGLE - 1-1/2" X 1-1/2" X 96" (INT WALL TO CL INCL PARTITIONS)
(3) TRIM ANGLED 3" X 3" X 8FT GALVALUME EMBOSSED 26 GA
REFRIGERATION
F01 FREEZER :
KPC198LZOP-2E, R448A, VOLTS: 208-230-60-1,BTU:6240
KEL16-049-2EC-PR-8 VOLTS: 208-230-60-1,BTU:6503
TEMP: WALK-IN -10,AMBIENT TEMP: 90
6'-93 4 "
7'-53 4 "
6'-7
"
7'-3
"
36
1
4"
2
13
8"
2
13
8"
4
31
2
"
431
2"
1'-3
"
A
Freezer
OVERALL SIZE: 7'-5 3/4" X 7'-3" X 9'-0 1/4" (INDOOR)
6'-9 3/4"
6'-11" X 7'-8 1/2" X 9-0 1/4"
6'
-
1
1
"
6'
-
3
"
7'-8"
EQ
EQ
CL 42.5 X 92.75
CL 40.5 X 92.75
FL 42.5 X 92.75
FL 40.5 X 92.75
EQ
EQ
DAVID M
FULTON
C89429
^WIL-EN®NBErR
SIGNED 2-21-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
DW-1
DRAWN BY:
DATE:
CHECK BY:
DATE:
SHEET #
KAD
09/24/2021
AVANTI RESTAURANT
SOLUTIONS
2915 Tennessee Avenue North, Parsons, TN 38363 (731) 847-6361 *(800) 826-7036*
AD-2 of 2
UNIT #:
DEL TACO GLENDALE #153 REMODEL -
WALK-IN FREEZER
GLENDALE,CA 91201 USA
DRAWING #:
ORDER #:
QUOTE REVISION
DATE:
A202371R1
001
®
®
DOOR
SWEEP GASKET
HEATER WIRE
THRESHOLD
FLOOR PANEL
BOTTOM PLATE
FINISHED
FLOOR
4 1/8"3 5/8"
FLOOR OR
METAL SCREED
LATCH
STRIKE
LOCKS SPACED
@23" O.C.
(2) #14 x 1" HEX HEAD TEK
SCREWS (ICC-ESR-1976)
LOCATED @ 12" ON CENTER
1.5" x 1.5" TIE DOWN ANGLE
TO MATCH CEILING FINISH
ANTI-DELAMINATION BRACKET
AT EVERY ENTRANCE CONDUIT, FORCE SEALANT AROUND THE
EXTERIOR OF THE ELECTRICAL CONDUIT AND INSIDE THE CONDUIT
AROUND THE WIRES. FAILURE TO ELIMINATE AIRFLOW IN THE
CONDUIT WILL ALLOW MOISTURE TO DAMAGE ELECTRICAL
COMPONENTS ESPECIALLY LIGHTS WHICH
WILL NOT BE COVERED UNDER WARRANTY.
COVER PLATE
CONDUIT NUT
THERMAL RESISTIVE
CONDUIT SUCH AS
SCHEDULE 40 PVC.
J-BOX (AS NEEDED)
PANEL
LEAD WIRES TO BE PULLED
THROUGH CONDUIT
*NOTE*
FOR OUTDOOR WALK-IN,
DO NOT PENETRATE
CEILING PANELS.
DRILL THROUGH HOLE INSIDE CAMLOCK POCKET INTO
FOUNDATION USING 1/4" X 8" CARBIDE DRILL BIT.
DO NOT USE IMLPACT WRENCHES TO INSTALL INTO
HOLLOW CMU. AFTER DRILLING, BLOW DUST OUT
OF EACH HOLE USING COMPRESSED AIR.
BE SURE DRILL AND ANCHOR
DO NOT COME INTO CONTACT
WITH LOCK PIN
4" FLOOR OR
METAL SCREED
DRIVE SIMPSON STRONG TIE TITEN HD SEISMIC ANCHOR THDB25412CS
(ICC ESR-2713 FOR CRACKED AND UNCRACKED CONCRETE AND ICC ESR-1056 FOR
MASONRY) UNTIL THE BOTTOM OF THE COUNTERSUNK HEAD CONTACTS BOTTOM
OF THE CAM LOCK POCKET. THE HEAD WILL SLIGHTLY EXPAND CAM POCKET,
BE SURE ANCKOR WILL NOT INTERFERE WITH MATING CAM LOCK HOOK.
FASTENER @ 11.5" ON CENTER
2" MIN.
EMBED
1/4" MIN.
OVERDRILLSIDE VIEW
CONCRETE SLAB ASSUMED TO BE 4” MINIMUM THICKNESS
AND 2500PSI MINIMUM COMPRESSIVE STRENGTH
COMPARTMENT
DESCRIPTION
TEMP F
WI QTY MODEL#
COMPRESSOR
TYPE L (A) W (B)LBS
DIMENSIONS
H (C)
CONNECTIONS O.D.
VV SUCTФHZ FLALRAHP
COMPRESSOR
RLA
TOTAL
AMPS
MX AMP
DISC
CONDENSER FAN MTR
Ф LIQ @ 90% FULL (lbs)
RCV CAP
CONDENSING UNIT
REFRIGERANT
1-10 KPC198LZOP-2E 33SCROLL 18625.5 19.25 13.62 208-23061 60 1 1.2 208-230 15.11 30 10.4F01 FREEZER 7/8 3/8R448A
COMPARTMENT
DESCRIPTION
TEMP F
WI QTY
MODEL #
(DEFROST: A-AIR E-ELECTRIC)L (D) W (E) H (F)LBS
DIMENSIONS
TOTAL AMPS V
FAN
UNIT COOLER
TOTAL AMPS
HEATER
V Ф SUCT
CONNECTIONS O.D.
DRAINLIQREFRIGERANT
-10 1 KEL16-049-2EC-PR-8 27.125 15.5 47 116.75 208-230 3/44.9 3/8208-230 5/80.5F01 FREEZER R448A SUCTION AND
LIQUID LINE
AIR INLET
CONDENSING UNIT ASSEMBLY
A
B
C
CLEARANCE REQUIREMENT
MINIMUM CLEARANCE
REQUIRED FOR
PROPPER OPERATION
AIR FLOW
SIDE VIEW
36"
REQUIRED
FOR
SERVICING
18"
ELECTRICAL
CONNECTIONS
(IN REAR)
SUCTION
CONNECTION
(IN REAR)
D
EVAPORATOR - MODEL AM, EM, EL, AMB, ELB
LIQUID
(IN REAR)MPT DRAIN
CONNECTION
E
F
58"
443
4"
FRAME:
RECESSED 0" WITH 0" LEVELING SAND AND 0" TILE AND GROUT
EXT: GALVALUME - EMBOSSED 26 GA
INT: ALUMINUM - EMBOSSED WHITE .040
PLUG:
EXT: GALVALUME - EMBOSSED 26 GA
EXT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH
INT: ALUMINUM - EMBOSSED WHITE .040
INT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH
HARDWARE AND ACCESSORIES:
(1) 115/60/1 ELECTRICAL
(1) DOOR CLOSER - KASON 1094 BRUSHED CHROME (STD)
(1) HANDLE - KASON 28 WITH LOCKING ASSEMBLY (STD)
(1) HEATER WIRE, 5 WATT / FT
(2) HINGE - KASON 1346 BRUSHED CHROME ADJUSTABLE / SPRING ASSISTED
(STD)
(1) LIGHT FIXTURE - KASON 1803 LED W/BULB, GLOBE AND NIGHTLIGHT
120V (STD)
(1) STRIP CURTAIN 36X78
(1) SWITCH - WEATHERPROOF PRESS 120/230V
(1) THERMOMETER - 2 INCH DIAL W/6' LEAD (STD)
(3) THRESHOLD, STAINLESS STEEL 14 GA
(1) VENT - PRESSURE RELIEF, HEATED KASON 1825 (STD)
DOOR ELECTRICAL INFORMATION
DESCRIPTION QTY VOLT AMP AMP LOAD
115 VOLT, SINGLE PHASE, 60 Hz, TOTAL DOOR AMPS: 0
A
DETAIL - 4IN FLOOR-HTR WIRE
Scale: NTS1
DETAIL - PANEL CONNECTION AT FLOORS OR METAL
SCREEDS
Scale: NTS2
DETAIL - TIE DOWN ANGLE-INT WALL TO CL INCLUDING
PARTITIONS
Scale: NTS3
DETAIL - FOOT-LIGHT ROLLING CART FLOOR
CONSTRUCTION
Scale: NTS4 DETAIL - ELECTRICAL CONDUIT PENETRATION
Scale: NTS5 DETAIL - TITEN HD ANCHOR
Scale: NTS6
NOTE:
(*) 1/4″ X 4″ X 3′ ALUMINUM DOOR THRESHOLD. THETHRESHOLD IS MADE OF
DURABLE ALUMINUM AND DESIGN TO WIHSTAND HEAVY TRAFFIC. PROVIDE
SMOOTH TRANSITION BETWEEN FLOOR AND DOOR, CORROSION-RESISTANT.
(*)
DAVID M
FULTON
C89429
^WIL-EN®NBErR
SIGNED 2-21-2024
2300 N Tustin Ave -
101117751-52 & 30146715
8/22/2024
Rev: 02/01/2023 Page 1 of 2
DISABLED ACCESS COMPLIANCE
ACC-01 CBC 2022 A. PURPOSE OF THIS DOCUMENTATION: (check one)
Finding of unreasonable hardship for projects UNDER the valuation threshold*
Finding of unreasonable hardship for projects OVER the valuation threshold*
Certification of Full Compliance with the 2022 California Building Code
* Valuation threshold as defined in the 2022 California Building Code, Section 11B-202.4 (Exception #8) and
Section 202 is $195,358.00 (as of January 2023)
B. PROJECT INFORMATION TO BE COMPLETED BY PETITIONER:
Project Address:
$ $
1. The cost of all construction contemplated in the determination of the valuation of improvement threshold
based on the valuation of site and building improvements for the last three-year period.
2. 20% of Total Construction Cost or Project Valuation: $
3. The actual amount to be spent to provide disabled access: $
4. Describe the impact of the proposed improvements on financial feasibility of the project.
5. Describe the proposed improvements related to accessibility upgrades on this project.
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
X
2300 N. Tustin Ave., Santa Ana, CA 92705
Restaurant TI
Del Taco #130 / Del Taco, LLC
Devling Place Apartments
714-541-3722
949-706-4727
220,000
Accessible work as part of the scope will bring the building into full compliance .
The accessible parking space will be moved where the grades work and a path to
the right of way will be built. The restrooms will comply and all needed clearances
are shown on the site and floor plans. There will be no hardship needed with work
to achieve full compliance included in the project scope.
30146715
1
Full compliance provided.
15,000
44,000
15,000
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
6. Identify the accessibility features and equivalent facilities that WILL be brought into compliance with the
latest edition of Title 24 as a part of this project and an estimate of the cost of each item: (Documentation
may be required)
Accessible Features to be Made Accessible Cost of Improvement
a. Entrance:
Door Landing Stairway/Steps Ramp $
b. Path of Travel:
Path of travel from accessible parking to the building entrance
and area of remodel $
$
Path of travel from the public way to the building entrance $
c. Sanitary facilities ( Floor no. ) $
d. Public phone(s) $
e. Drinking fountain(s) $
f. Parking $
g. Signage & Alarms $
i. Other: $
Total: $
7. Identify the accessibility features that WILL NOT comply if a request for unreasonable hardship is
granted. Provide an estimated cost of compliance for each item: (Documentation may be required)
Accessible Features Not to be Improved Cost of Improvement
a. $
b. $
c. $
Total: $
8. Petitioner must be the legal property owner or his/her legal representative:
I certify that the above noted information is true and correct.
Legal Property Owner Architect/Engineer Contractor Other:
Print Name: Phone No.
Address:
Signature: Date:
FOR AGENCY USE ONLY
Approved by: Date:
X
X
8,500
6,500
15,000
X
Paul Deppe, ADN Architects
1330 Olympic Blvd., Santa Monica, CA 90404
310-503-7778
resigned 5-15-2024
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
STRUCTURAL CALCULATIONS
PROJECT: Del Taco, Santa Ana, CA
DESIGN ASSUMPTIONS
Concrete Strength at 28 days: ≔f'c 2500 psi
Masonry (Grade N Concrete Block): ≔f'm 2000 psi
Mortar (Type S): ≔f'm 2000 psi
Grout:≔f'g 2000 psi
Reinforcing Steel:A-615 Grade 40 (#4 and less)≔Fy40 40000 psi
Grade 60 (#5 and larger)≔Fy60 60000 psi
Structural Steel: A-36 Yield Strength:≔Fy 50000 psi
Lumber: Douglas Fir-Larch ≔Es ⋅29 10 6 psi
4x Joists, Beams and Posts: #2 (UON)≔Fv4x 95 psi
≔Fb4x 900 psi
≔E4x ⋅1.6 10 6 psi
6x Joists, Beams and Posts: #1 (UON)≔Fv6x 85 psi
≔Fb6x 1350 psi
≔E6x ⋅1.6 10 6 psi
Studs:Stud Grade (UON)
Manufactured: PSL:≔FvPSL 290 psi LSL:≔FvLSL 310 psi
≔FbPSL 2900 psi ≔FbLSL 2325 psi
≔EPSL ⋅2.0 10 6 psi ≔ELSL ⋅1.55 10 6 psi
DESIGN LOADS:
ROOF DEAD LOAD FLOOR DEAD LOAD WALL DEAD LOAD
SLOPING FLAT INTERIOR EXTERIOR ≔DLwallext 16 psf
Roofing:
Plywood:
Joists:
Insul. & Clg:
Sprink:
Misc:
4 psf
2 psf
5 psf
1 psf
2 psf
2 psf
Flooring:
Plywood:
Joists:
Insul. & Clg:
Sprink:
Misc:
2 psf
2 psf
5 psf
2 psf
2 psf
1 psf
4 psf
2 psf
5 psf
2 psf
2 psf
1 psf
≔DLwallint 10 psf
ROOF LIVE LOAD
≔LLroofslope 20 psf
≔LLroofflat 20 psf
≔DLroofslope 16 psf ≔DLfloorint 14 psf FLOOR LIVE LOAD
≔DLroofflat 16 psf ≔DLfloorext 16 psf ≔LLfloorint 40 psf
≔DLtrellis 3 psf ≔LLfloorext 60 psf
≔LLfloorexit 100 psf
SOIL DESIGN VALUES
Report by: CBC MINIMUMS Reporty No.: N/A
Report Date: 2019 CBC Bearing Pressure: ≔qb 1500 psf
These calculaons are limited only to the items included herein, selected by the client and do not imply approval
of any other poron of the structure by this office. These calculaons are not valid if altered in any way, or not
accompanied by a wet stamp and signature of the Engineer of Record.
Job No.Designed By Date
24-315 RT 2/12/2024
LATERAL ASSUMPTIONS:
San Diego -14288 Danielson Street, Suite # 200, Poway, CA 92064, (858) 679-8989, Fax (858) 679-8959
Signed: 5-15-2024
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
Job No:
Basic Parameters
Wind Directionality Factor, Kd 0.85 Table 26.6-1
Topographic Factor, Kzt 1.00 Section 26.8
Ground Elevation Factor, Ke 1.00 Table 26.9-1
Internal Pressure Coefficient, GCpi +/- 0.18 Table 26.11-1
Pressure Coefficients
Wall External Pressure Coefficient, GCpf 0.53 Table 28.4-1, Surface 1
Roof External Pressure Coefficient, GCpf -0.69 Table 28.4-1, Surface 2
Roof External Pressure Coefficient, GCpf -0.48 Table 28.4-1, Surface 3
Wall External Pressure Coefficient, GCpf -0.43 Table 28.4-1, Surface 4
Structure Pressure Summary (Add Internal Pressure qzGCpi or qhGCpi as Necessary) (Normal to Roof Slope)
Windward Leeward Total*0.6 Windward Leeward Total*0.6 Uplift Gcp Pnet*0.6
-8.6 psf 11.1 psf -8.6 psf 0.0 psf -2.2 psf
-8.6 psf 11.1 psf -8.6 psf 0.0 psf -2.2 psf
-8.6 psf 11.1 psf -8.6 psf 0.0 psf -2.2 psf
-8.6 psf 11.1 psf -8.6 psf 0.0 psf -2.2 psf
-9.3 psf 12.1 psf -9.3 psf 0.0 psf -2.4 psf
-9.9 psf 12.9 psf -9.9 psf 0.0 psf -2.5 psf
-10.4 psf 13.5 psf -10.4 psf 0.0 psf -2.7 psf
Structure Pressure Summary (Add Internal Pressure qzGCpi or qhGCpi as Necessary) (Normal to Gable or Parapet)
Parapets
Windward Leeward Total*0.6 Windward Leeward Total*0.6 Uplift Gcp Pnet*0.6 Pnet*0.6
-6.6 psf 8.8 psf -8.6 psf 0.0 psf -2.2 psf 21.1 psf
-6.6 psf 8.8 psf -8.6 psf 0.0 psf -2.2 psf 21.1 psf
-6.6 psf 8.8 psf -8.6 psf 0.0 psf -2.2 psf 21.1 psf
-6.6 psf 8.8 psf -8.6 psf 0.0 psf -2.2 psf 21.1 psf
-7.2 psf 9.6 psf -9.3 psf 0.0 psf -2.4 psf 22.9 psf
-7.6 psf 10.2 psf -9.9 psf 0.0 psf -2.5 psf 24.4 psf
-8.0 psf 10.7 psf -10.4 psf 0.0 psf -2.7 psf 25.6 psf
Del Taco - Santa Ana
Positive means
no uplift
Negative can
be ignored
C&C WallsRoofs
C&C WallsRoofs
2/12/2024
MWFRS Wind Loads
ASCE 7-16
Enclosed & Partially Enclosed Low Rise Buildings (Chapter 28, Part 1)
Enclosed
Height, z K z q z
Walls
q zKzHeight, z
Page 1 of 1
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
STRUCTURAL CALCULATIONS
LATERAL ASSUMPTIONS:
WIND DESIGN (See Printout)
Basic Wind Speed:≔W 96 mph ≔Pw 11.1 psf ≔Pparapet =⋅Pw ⎛⎝+1 1.5⎞⎠27.75 psf
Exposure C ≔Pwind25 27.75 psf
Wind Pressure:≔PW Pwind25
First Floor Wall Height:≔PLHT 12.5
Parapet Height:≔ParaHT 5
Tower Height:≔Paratower 9
Roof Wall Pressure:≔Wroof =⋅Pwind25 ―――――
⎛⎝+PLHT ParaHT⎞⎠
2
⋅2 PLHT
340 plf
SEISMIC DESIGN
Risk Category:II
Site Class:D
Response Modificaon Coefficient:≔R 6.5 ASD Load Cases Used (Worse Cases)
(ASCE7-16 2.4 & 2.45)Seismic Design Value:≔SDS 1.19
Redundancy:≔ρ 1.3 1. DL
2. DL + LL
3. DL+ 0.6W (Wind)
4. DL+0.7Eh (Seismic)
Seismic Response Coefficient:≔CS =――SDS
R
0.183
Design Base Shear:≔Vbs =⋅0.7 CS ρ 0.167 ≔Ev =−0.6 ⋅⋅0.7 0.2 SDS 0.43
BASE SHEAR
≔wallext 10 psf ≔DL DLroofflat ≔LL LLroofflat ≔TL +DL LL
≔wallint 5 psf
≔ws =+DLroofflat wallext wallint 31 psf
≔VB =⋅Vbs ws 5.16 psf
Lateral & Overturning Analysis (New wall line at overhang, exisng wall not to be modified)
Line 1
≔V1EQ ⋅VB
⎛
⎝
⎛
⎝⋅43 ――5
2
⎞
⎠
⎞
⎠
=V1EQ 555.19 lbf
≔P1W ⋅Pwind25
⎛
⎝⋅
⎛
⎝
PLHT
2
⎞
⎠
⎛
⎝
5
2
⎞
⎠
⎞
⎠=P1W 433.59 lbf
≔F1 max ⎛⎝,V1EQ P1W⎞⎠
=F1 555.19 lbf
Wall Length
≔L11 12.8 ≔L12 0
≔M1OT ―――⋅F1 PLHT
2
=M1OT 3469.97 ⋅lbf
cont. on next page...
San Diego -14288 Danielson Street, Suite # 200, Poway, CA 92064, (858) 679-8989, Fax (858) 679-8959
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
STRUCTURAL CALCULATIONS
≔M1RES ⋅Ev ―――――――――――――
⋅⎛
⎝+⎛
⎝DL ――5
2
⎞
⎠16 psf ⎛⎝+PLHT ParaHT⎞⎠
⎞
⎠L11⎞⎠2
2
=M1RES 11361.32 ⋅lbf
≔UPLIFT1 ――――−M1OT M1RES
L11
=UPLIFT1 −616.51 lbf
≔V1S ――F1
L11
=V1S 43.37 ―lbf
Use 3/8" min. ply w/ 8d @ 6"
o.c. (B.N. & E.N.)
Check new tower wind load against MWFRS (parapet
heights to match exisng mansard height therefore no new
wind loads are present in these areas.
≔Pwexisng =⋅Pwind25
⎛
⎝
⋅+PLHT ParaHT⎞⎠
2
⋅2 PLHT
55
⎞
⎠
18696.56 lbf
≔Pwnew =⋅Pwind25
⎛
⎝
+
⎛
⎝
⋅+PLHT ParaHT⎞⎠
2
⋅2 PLHT
45
⎞
⎠
⎛
⎝
⋅
⎛
⎝
⎛
⎝
+PLHT Paratower⎞⎠
2
⋅2 PLHT
⎞
⎠
⎞
⎠
10
⎞
⎠
⎞
⎠
20428.16 lbf
≔Percentincrease =⋅
⎛
⎝
−Pwnew Pwexisng ⎞⎠
Pwnew
⎞
⎠
100 8.48 %
New tower loads are less an increase of
8.48% (less than 10%), therefore no
retrofit to the MWFRS is required.
Exisng lateral condions are adequate.
Parapet Analysis
≔pwind 27.75 psf
≔M =―――――――⋅⋅pwind 1.33 ⎛⎝5 ⎞⎠
2
2
461.34 ⋅lbf
≔Sxreq =――――M
⋅.6 33000 psi
0.28 in 3 Parapet Studs -362S162-33 @
16" o.c.
≔Connecon =⋅⋅pwind 1.33 ―――――
――――⎛⎝+5 5 ⎞⎠
2
⋅2 5
cos ⎛⎝45 °⎞⎠521.95 lbf Tension/compression & pullout
load
at brace
≔Areqbrace =――――⋅Connecon 2
33000 psi
0.03 in 2 Braces -362S162-33 @ 32" o.c.
-2-#10 ea. end of brace 3-#8 x
3" ea. blk & joist (typ.)
San Diego -14288 Danielson Street, Suite # 200, Poway, CA 92064, (858) 679-8989, Fax (858) 679-8959
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
STRUCTURAL CALCULATIONS
Gravity Analysis
Hallway Framed Wall Headers (Worst Case)
≔LB1 15
≔wB1 =⎛
⎝⋅TL ――4
2
⎞
⎠72 plf
≔vB1 =⋅wB1 ―LB1
2
540 lbf
≔MB1 =⋅wB1 ――LB1
2
8
2025 ⋅lbf
≔Sx1req =――――MB1
⎛⎝⋅Fb4x 1.25⎞⎠
21.6 in 3
≔IB1req =――――――――
⎛⎝⋅⋅⋅5 wB1 LB1
4 1728⎞⎠
⋅⎛
⎝384 E4x
⎛
⎝LB1 ――12
240
⎞
⎠
⎞
⎠12 2
68.34 in 4
(N) 4x12
Foundaon Analysis (worse case)
≔wframing =⋅⎛
⎝+⎛
⎝⋅TL ――33
2
⎞
⎠⋅DLwallext PLHT⎞⎠
⎞
⎠1 794 lbf
≔wconc =⋅⋅⋅150 pcf 1.5 1 1 225 lbf
≔wfoong =+wframing wconc 1019 lbf
12" wide min. x 18" deep
foong w/ 2 -#4 top & boom
minimum (unless stated by soils
report)
≔Afoong =―――wfoong
qb
0.68 2
≔bfoong =‾‾‾‾‾Afoong 9.89 in
San Diego -14288 Danielson Street, Suite # 200, Poway, CA 92064, (858) 679-8989, Fax (858) 679-8959
STOREFRONT ANALYSIS BASED ON DETAIL A603. 2
GLAZED OPENINGS +/- 15' LENGTH.
BASED ON STANDARD ALUMINUM CENTER
STYLE JAMB CONDITION. WOOD HEADERS
AT EACH OPENING HAVE BEEN SIZED
ACCORDINGLY PER PLAN.
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
STRUCTURAL CALCULATIONS
LATERAL ASSUMPTIONS:
Anchor Design for Walkin Cooler
SEISMIC DESIGN
Risk Category:II
Site Class:D
Seismic Design Value:≔SDS 1.067
Importance Factor:≔Ip 1.0
Wall Weight:≔Wp 16 psf
Wall Height:≔h 9
≔l 10
≔w 9
Anchor Spacing:≔Sa 11.5 in
Wall Force:≔Vmax =―――――
⎛
⎝5 psf w ―l
2
⎞
⎠
w
25 ―lbf
Out of Plane Wall Force:≔Fp =⋅⋅⋅0.4 SDS Ip Wp 6.829 psf
Anchor Force:=⋅⋅Fp Sa ―h
2
29.45 lbf
Upli at End Wall:≔Fup =――――
⋅⎛
⎝Fp ―h
2
l
⎞
⎠h
w
307.3 lbf
Cooler Length:
Cooler Width:
-Use 1/4" dia. TAPCON screw
anchor w/ 1.25" min. embed @
11.5" on center (typ).
San Diego -14288 Danielson Street, Suite # 200, Poway, CA 92064, (858) 679-8989, Fax (858) 679-8959
ONS 2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
! !
"#$ !%%
"&'()' *+,-.,/
0#')1 23,4567839:,5;7*5,6 <=7>33,+;?@;++A+;BC
DEFF& ! ! %
GHIJ
GHIJ
KF$&LMFN
O//5PQR+=/ 4SB O44;3T+97U45=7>Q5;/BC49V W
7 XOY> !C49V W
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
BOARD OF
BUILDING AND SAFETY
COMMISSIONERS
____
VAN AMBATIELOS
PRESIDENT
JAVIER NUNEZ
VICE PRESIDENT
JOSELYN GEAGA-ROSENTHAL
GEORGE HOVAGUIMIAN
ELVIN W. MOON
____
CITY OF LOS ANGELES
CALIFORNIA
ERIC GARCETTI
MAYOR
DEPARTMENT OF
BUILDING AND SAFETY
201 NORTH FIGUEROA STREET
LOS ANGELES, CA 90012
____
OSAMA YOUNAN, P.E.
GENERAL MANAGER
SUPERINTENDENT OF BUILDING
JOHN WEIGHT
EXECUTIVE OFFICER
____
RR 24808
Page 1 of 3
LADBS G-5 (Rev.02/20/2014) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER
Welbilt RESEARCH REPORT: RR 24808
(Kolpak and Hardford Brands) (CSI # 13030)
2915 Tennesee Avenue N
Parsons, TN 38363 Expires: January 1, 2023
Issued Date: April 01, 2021
Attn: Tony Moffett Code: 2020 LABC
(731) 847-5629
GENERAL APPROVAL –Renewal - Kolpak Modular Walk-In Cooler/Freezers.
DETAILS
Kolpak prefabricated wall and ceiling panels consist of a 4-inch-thick minimum 2-part spray-in
polyurethane foam core with 26 gage (0.019”) aluminum coated galvanized steel, 16-22 gage
galvanized steel (uncoated or galvanealed), or 0.040” aluminum skin. Part A of the polyurethane
foam is Voracor CE 108 Isocyanate by DOW, part B is Voracor CD 2101 by DOW. The average
in-place density of the foam is 2.22 pounds per cubic foot. Max panel width is 46 inches. The
Panels are fastened together by use of Posi-Loc fastening devices along the edges. Flame spread
index and smoke developed index ratings are less than 75 and 450 respectively for the core
material. Surface burning characteristics of the finished building unit do not exceed 25 for flame
spread index and 450 for smoke developed index. Flash ignition and self-ignition temperatures
exceed the minimum required temperatures of 600°F and 800°F, respectively.
Kolpak freestanding walk-in coolers and freezers constructed of panels described above
are approved with the following requirements:
1. The coolers and freezers may be installed in the interior of buildings and outdoors.
2. Height of units shall not exceed 20 feet.
3. An approved fire-retardant roof covering (class “A” or “B”) consistent with ASTM E108
shall be installed over the panels when used as an outdoor roof panel.
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
Kolpak
RE: Kolpak Modular Walk-In Cooler/Freezer
RR 24808
Page 2 of 3
4. The panels shall be considered combustible and may be installed only in areas where
combustible materials are permitted by the Code.
5. Complete design calculations, including the panel connections to the foundation or
building substrate, shall be submitted to the Structural Plan Check Section for each
project. Plans and calculations shall bear the stamp and signature of a licensed civil or
structural engineer or architect.
6. Refer to attached tables for allowable panel loads. No increase in allowable stress is
allowed for the values indicated above for short duration of loads due to wind or seismic
forces.
7. Where the aggregate enclosed area of the cooler and/or freezer exceeds 400 square feet,
one of the two following conditions shall be met:
a. A thermal barrier of shall be installed to separate the foam plastic from the
interior of the building per Section 2306.4 of the Los Angeles Building Code.
b. The cooler/freezer shall be protected by an automatic sprinkler system in
accordance with Section 903.3.1.1 of the Los Angeles Building Code.
Furthermore, where the unit is within a building, both the cooler/freezer and that
part of the building in which it is located shall be sprinklered.
8. Panels fabrication shall follow regulations and only be fabricated by a Type I licensed
shop that is approved by the Los Angeles Building Department. Type II fabricators are
required when piping or other utilities are in the walls or ceilings. Shops not licensed by
the Los Angeles City Building Department will invalidate this approval.
DISCUSSION
The report is in compliance with the 2020 City of Los Angeles Building Code.
The approval is based on the foam plastic insulation requirements of Section 2603 and structural
tests and analysis.
Addressee to whom this Research Report is issued is responsible for providing copies of it,
complete with any attachments indicated, to architects, engineers and builders using items
approved herein in design or construction which must be approved by Department of Building
and Safety Engineers and Inspectors.
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
Kolpak
RE: Kolpak Modular Walk-In Cooler/Freezer
RR 24808
Page 3 of 3
This general approval of an equivalent alternate to the Code is only valid where an engineer
and/or inspector of this Department has determined that all conditions of this approval have been
met in the project in which it is to be used.
____________________________________
QUAN NGHIEM, Chief
Engineering Research Section
201 N. Figueroa St., Room 880
Los Angeles, CA 90012
Phone- 213-202-9812
Fax- 213-202-9943
QN
RR24808
TLB2100051
R04/01/2021
2603
Attachment: Certified Panel Span Tables (2 pages)
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
KOLPRK
PLANNORTH
A Welbilt Brand
• SPAN CHART • Allowable Applied Load fpsQ
Length
Standard Core Super Era OS
4 in 5 in*6 in 4 in 4 in 6 in
U180 U240 L/180 U240 U180 1/240 U240 (+)L/240 (•)L/240 (+)L/240 (-)U240 (+)L/240 (-)
5'135 104 175 135 214 165 191 195 398 405 388 396
5'-6'120 94 153 120 187 147 172 170 356 363 368 376
6'106 84 134 107 163 130 155 149 318 326 349 357
6'-6'93 76 118 96 142 115 140 130 285 293 331 339
T 83 68 103 85 123 102 126 114 255 263 314 322
r-6'73 62 90 76 108 91 114 99 228 236 297 306
8'65 55 79 68 94 81 103 87 204 212 282 291
CO
m
57 50 69 61 82 72 93 76 182 191 268 276
9'50 45 61 54 71 64 84 66 163 171 254 262
9'-6'45 41 53 48 62 56 75 58 146 154 241 249
10'39 37 47 43 54 50 68 51 130 138 228 236
10"-6"35 33 41 39 47 44 61 44 117 124 216 225
11'31 30 36 35 41 39 55 39 104 111 205 213
11'-6"27 27 31 31 36 35 50 34 93 100 195 203
12'24 24 28 28 31 31 45 29 83 90 185 192
12'-6"22 22 25 25 28 28 41 27 77 82 172 181
13'21 21 23 23 26 26 37 25 71 76 160 170
13'-6"19 19 21 21 23 23 34 23 65 70 149 159
14'18 18 19 19 21 21 31 21 60 64 138 148
14'-6"16 16 18 18 19 19 28 20 55 59 129 139
15'15 15 16 16 17 17 25 18 51 55 119 129
IS'-e"14 14 15 15 16 16 23 17 47 51 111 121
16'13 13 13 13 14 14 21 16 43 47 103 113
16'-6-12 12 12 12 13 13 19 15 40 43 96 106
17 11 11 11 11 12 12 17 14 37 40 89 99
17-6"10 10 10 10 11 11 16 13 34 37 83 92
18'9 9 9 9 9 9 14 12 31 34 77 86
18'-6"8 8 9 9 9 9 13 11 29 31 72 81
19'8 8 8 8 8 8 12 10 26 29 67 75
19'-6"7 7 7 7 7 7 11 9 24 26 62 71
20'7 7 7 7 6 6 9 9 22 24 58 66
Self Weight:2.5 psf 2,75 psf 3 psf 4.2 psf 6.4 psf 8 psf
V/near interpolatd values
Does not meet minimum outdoor L, =20 psf
Does not meet minimum indoor L, = 10psf
DAVID M
FULTON
C89429
..CIVIL-B^lNEeR'
m
Standard Core: Unreinforced indoor/outdoor panel
Super Hat channel reinforced panel w/ 20 6a exterior skin
Era OS: High capacity reinforced panel w/ 20 Ga exterior skin
Notes: P^nel capacities shown are based on the maximum permisable loading normal to the panel span direclioir^^WS'
to achieve the specified deflection criteria or the allowable stress load (applied FOS = 3) whichever was
more stringent. (NTA test report KLPK091719-108 05/22/2020)
Panel self weight may be added to the listed positive load capacity when designing
wall configurations.
Specifier shall check combined stress of transverse and axial __ rransgppned Axialgppnea < ^ g
loads on wall panel using the following equation: combined - rransm,owadie A*«a'aiit)wabie"
LARR 24808 2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
»>► KOLPPK
A Welbilt Brand
PLANNORTH
t K t . -
IN-PLANE SHEAR CAPACITY
h/L Allowable Load
2 93 pif
4 43 pif
4"170 pif
'b ■ 14 Ga base angle fastened directly to panel using #14 screws @3 in o.c.
PANEL AXIAL CAPACirr
Skin Type 4 in.
Panel Thickness
5 in.6fn.
Ga/Ga 593 pif 485 pif 376 pif
Al/AI 414 pif 338 pif 263 pif
Ga/Al 477 pif 390 pif 302 pif
'Panels height nof te exceed 20 ft.
PANEL CAMLOCK CAPACITY
Loading Mode Max Allowable Load
IN-PLANE SHEAR 176.3 lb
TENSION 203.3 lb
OUT-OF-PLANE SHEAR 131.7 lb
OUT-OF-PLANE SHEAR"171.1 lb
'b - includes racking dip in camlock houdng
DAVID M
FULTON
C89429
^WIL-EN®NBErR
LARR 24808 2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
STRUCTURAL CALCULATIONS
LATERAL ASSUMPTIONS:
Anchor Design for Walkin Cooler
SEISMIC DESIGN
Risk Category:II
Site Class:D
Seismic Design Value:≔SDS 1.067
Importance Factor:≔Ip 1.0
Wall Weight:≔Wp 16 psf
Wall Height:≔h 9
≔l 10
≔w 9
Anchor Spacing:≔Sa 11.5 in
Wall Force:≔Vmax =―――――
⎛
⎝5 psf w ―l
2
⎞
⎠
w
25 ―lbf
Out of Plane Wall Force:≔Fp =⋅⋅⋅0.4 SDS Ip Wp 6.829 psf
Anchor Force:=⋅⋅Fp Sa ―h
2
29.45 lbf
Upli at End Wall:≔Fup =――――
⋅⎛
⎝Fp ―h
2
l
⎞
⎠h
w
307.3 lbf
Cooler Length:
Cooler Width:
-Use 1/4" dia. TAPCON screw
anchor w/ 1.25" min. embed @
11.5" on center (typ).
San Diego -14288 Danielson Street, Suite # 200, Poway, CA 92064, (858) 679-8989, Fax (858) 679-8959
ONS 2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
! !
"#$ !%%
"&'()' *+,-.,/
0#')1 23,4567839:,5;7*5,6 <=7>33,+;?@;++A+;BC
DEFF& ! ! %
GHIJ
GHIJ
KF$&LMFN
O//5PQR+=/ 4SB O44;3T+97U45=7>Q5;/BC49V W
7 XOY> !C49V W
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
BOARD OF
BUILDING AND SAFETY
COMMISSIONERS
____
VAN AMBATIELOS
PRESIDENT
JAVIER NUNEZ
VICE PRESIDENT
JOSELYN GEAGA-ROSENTHAL
GEORGE HOVAGUIMIAN
ELVIN W. MOON
____
CITY OF LOS ANGELES
CALIFORNIA
ERIC GARCETTI
MAYOR
DEPARTMENT OF
BUILDING AND SAFETY
201 NORTH FIGUEROA STREET
LOS ANGELES, CA 90012
____
OSAMA YOUNAN, P.E.
GENERAL MANAGER
SUPERINTENDENT OF BUILDING
JOHN WEIGHT
EXECUTIVE OFFICER
____
RR 24808
Page 1 of 3
LADBS G-5 (Rev.02/20/2014) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER
Welbilt RESEARCH REPORT: RR 24808
(Kolpak and Hardford Brands) (CSI # 13030)
2915 Tennesee Avenue N
Parsons, TN 38363 Expires: January 1, 2023
Issued Date: April 01, 2021
Attn: Tony Moffett Code: 2020 LABC
(731) 847-5629
GENERAL APPROVAL –Renewal - Kolpak Modular Walk-In Cooler/Freezers.
DETAILS
Kolpak prefabricated wall and ceiling panels consist of a 4-inch-thick minimum 2-part spray-in
polyurethane foam core with 26 gage (0.019”) aluminum coated galvanized steel, 16-22 gage
galvanized steel (uncoated or galvanealed), or 0.040” aluminum skin. Part A of the polyurethane
foam is Voracor CE 108 Isocyanate by DOW, part B is Voracor CD 2101 by DOW. The average
in-place density of the foam is 2.22 pounds per cubic foot. Max panel width is 46 inches. The
Panels are fastened together by use of Posi-Loc fastening devices along the edges. Flame spread
index and smoke developed index ratings are less than 75 and 450 respectively for the core
material. Surface burning characteristics of the finished building unit do not exceed 25 for flame
spread index and 450 for smoke developed index. Flash ignition and self-ignition temperatures
exceed the minimum required temperatures of 600°F and 800°F, respectively.
Kolpak freestanding walk-in coolers and freezers constructed of panels described above
are approved with the following requirements:
1. The coolers and freezers may be installed in the interior of buildings and outdoors.
2. Height of units shall not exceed 20 feet.
3. An approved fire-retardant roof covering (class “A” or “B”) consistent with ASTM E108
shall be installed over the panels when used as an outdoor roof panel.
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
Kolpak
RE: Kolpak Modular Walk-In Cooler/Freezer
RR 24808
Page 2 of 3
4. The panels shall be considered combustible and may be installed only in areas where
combustible materials are permitted by the Code.
5. Complete design calculations, including the panel connections to the foundation or
building substrate, shall be submitted to the Structural Plan Check Section for each
project. Plans and calculations shall bear the stamp and signature of a licensed civil or
structural engineer or architect.
6. Refer to attached tables for allowable panel loads. No increase in allowable stress is
allowed for the values indicated above for short duration of loads due to wind or seismic
forces.
7. Where the aggregate enclosed area of the cooler and/or freezer exceeds 400 square feet,
one of the two following conditions shall be met:
a. A thermal barrier of shall be installed to separate the foam plastic from the
interior of the building per Section 2306.4 of the Los Angeles Building Code.
b. The cooler/freezer shall be protected by an automatic sprinkler system in
accordance with Section 903.3.1.1 of the Los Angeles Building Code.
Furthermore, where the unit is within a building, both the cooler/freezer and that
part of the building in which it is located shall be sprinklered.
8. Panels fabrication shall follow regulations and only be fabricated by a Type I licensed
shop that is approved by the Los Angeles Building Department. Type II fabricators are
required when piping or other utilities are in the walls or ceilings. Shops not licensed by
the Los Angeles City Building Department will invalidate this approval.
DISCUSSION
The report is in compliance with the 2020 City of Los Angeles Building Code.
The approval is based on the foam plastic insulation requirements of Section 2603 and structural
tests and analysis.
Addressee to whom this Research Report is issued is responsible for providing copies of it,
complete with any attachments indicated, to architects, engineers and builders using items
approved herein in design or construction which must be approved by Department of Building
and Safety Engineers and Inspectors.
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
Kolpak
RE: Kolpak Modular Walk-In Cooler/Freezer
RR 24808
Page 3 of 3
This general approval of an equivalent alternate to the Code is only valid where an engineer
and/or inspector of this Department has determined that all conditions of this approval have been
met in the project in which it is to be used.
____________________________________
QUAN NGHIEM, Chief
Engineering Research Section
201 N. Figueroa St., Room 880
Los Angeles, CA 90012
Phone- 213-202-9812
Fax- 213-202-9943
QN
RR24808
TLB2100051
R04/01/2021
2603
Attachment: Certified Panel Span Tables (2 pages)
2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
KOLPRK
PLANNORTH
A Welbilt Brand
• SPAN CHART • Allowable Applied Load fpsQ
Length
Standard Core Super Era OS
4 in 5 in*6 in 4 in 4 in 6 in
U180 U240 L/180 U240 U180 1/240 U240 (+)L/240 (•)L/240 (+)L/240 (-)U240 (+)L/240 (-)
5'135 104 175 135 214 165 191 195 398 405 388 396
5'-6'120 94 153 120 187 147 172 170 356 363 368 376
6'106 84 134 107 163 130 155 149 318 326 349 357
6'-6'93 76 118 96 142 115 140 130 285 293 331 339
T 83 68 103 85 123 102 126 114 255 263 314 322
r-6'73 62 90 76 108 91 114 99 228 236 297 306
8'65 55 79 68 94 81 103 87 204 212 282 291
CO
m
57 50 69 61 82 72 93 76 182 191 268 276
9'50 45 61 54 71 64 84 66 163 171 254 262
9'-6'45 41 53 48 62 56 75 58 146 154 241 249
10'39 37 47 43 54 50 68 51 130 138 228 236
10"-6"35 33 41 39 47 44 61 44 117 124 216 225
11'31 30 36 35 41 39 55 39 104 111 205 213
11'-6"27 27 31 31 36 35 50 34 93 100 195 203
12'24 24 28 28 31 31 45 29 83 90 185 192
12'-6"22 22 25 25 28 28 41 27 77 82 172 181
13'21 21 23 23 26 26 37 25 71 76 160 170
13'-6"19 19 21 21 23 23 34 23 65 70 149 159
14'18 18 19 19 21 21 31 21 60 64 138 148
14'-6"16 16 18 18 19 19 28 20 55 59 129 139
15'15 15 16 16 17 17 25 18 51 55 119 129
IS'-e"14 14 15 15 16 16 23 17 47 51 111 121
16'13 13 13 13 14 14 21 16 43 47 103 113
16'-6-12 12 12 12 13 13 19 15 40 43 96 106
17 11 11 11 11 12 12 17 14 37 40 89 99
17-6"10 10 10 10 11 11 16 13 34 37 83 92
18'9 9 9 9 9 9 14 12 31 34 77 86
18'-6"8 8 9 9 9 9 13 11 29 31 72 81
19'8 8 8 8 8 8 12 10 26 29 67 75
19'-6"7 7 7 7 7 7 11 9 24 26 62 71
20'7 7 7 7 6 6 9 9 22 24 58 66
Self Weight:2.5 psf 2,75 psf 3 psf 4.2 psf 6.4 psf 8 psf
V/near interpolatd values
Does not meet minimum outdoor L, =20 psf
Does not meet minimum indoor L, = 10psf
DAVID M
FULTON
C89429
..CIVIL-B^lNEeR'
m
Standard Core: Unreinforced indoor/outdoor panel
Super Hat channel reinforced panel w/ 20 6a exterior skin
Era OS: High capacity reinforced panel w/ 20 Ga exterior skin
Notes: P^nel capacities shown are based on the maximum permisable loading normal to the panel span direclioir^^WS'
to achieve the specified deflection criteria or the allowable stress load (applied FOS = 3) whichever was
more stringent. (NTA test report KLPK091719-108 05/22/2020)
Panel self weight may be added to the listed positive load capacity when designing
wall configurations.
Specifier shall check combined stress of transverse and axial __ rransgppned Axialgppnea < ^ g
loads on wall panel using the following equation: combined - rransm,owadie A*«a'aiit)wabie"
LARR 24808 2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
»>► KOLPPK
A Welbilt Brand
PLANNORTH
t K t . -
IN-PLANE SHEAR CAPACITY
h/L Allowable Load
2 93 pif
4 43 pif
4"170 pif
'b ■ 14 Ga base angle fastened directly to panel using #14 screws @3 in o.c.
PANEL AXIAL CAPACirr
Skin Type 4 in.
Panel Thickness
5 in.6fn.
Ga/Ga 593 pif 485 pif 376 pif
Al/AI 414 pif 338 pif 263 pif
Ga/Al 477 pif 390 pif 302 pif
'Panels height nof te exceed 20 ft.
PANEL CAMLOCK CAPACITY
Loading Mode Max Allowable Load
IN-PLANE SHEAR 176.3 lb
TENSION 203.3 lb
OUT-OF-PLANE SHEAR 131.7 lb
OUT-OF-PLANE SHEAR"171.1 lb
'b - includes racking dip in camlock houdng
DAVID M
FULTON
C89429
^WIL-EN®NBErR
LARR 24808 2300 N Tustin Ave -
101117751-52 & 301467158/22/2024
PARAPET FRAMING @ MANSARD
ARCH. FEATURE FRAMING @ MANSARD
SECTION THROUGH HALLWAY
BASE FLASHING
TYPICAL CRICKET
PARAPET FLASHING
PARAPET WEEP SCREED
A B
NOT USED NOT USED
NOT USED
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
T T
3 #3 X 3" SCREWS EACH BLK AND TOP
CHORD OF TRUSS
SEE 1/A21
SEE 1/A21
(N) 2X4 WD
2X4 WD LEDGER - 2
16D EACH STUD. 2X
BLOCKING IN BETWEEN
EACH STUD 16" O.C.
2X4 WD BRACING EVERY 48" -
NAIL TO SIDE OF EXISTING
STUDS - 16D MIN 2 PER STUD.
(N) 5/8" GYP BOARD
CEILING AT HALL
A
A CONTRACTOR SHALL INSTALL
MST 16 STRAPS ON ROOF
DECK AT NEW HALLWAY WALL
FASTENED TO EACH TOP
CHORD OF EXISTING TRUSS
FOR LENGTH OF NEW WALL.
(E) TRUSS
FRAMING REVISION
2/05/25
2/05/25 FRAMING REVISION
si
si
si
psi
EVERY 4'-0" (TRUSS SPACING)
2x4 B
R
A
C
I
N
G
E
V
E
R
Y
O
T
H
E
R
T
R
U
S
S
2
-
1
6
D
M
I
N
E
A
E
N
D
INFILL BLOCKING/BRACING
Revision to #101117751 (issued on 2/22/24)
REV 1 - #101122567
APPROVALS:
PLNG - C. Santana
BLDG - CSG
2300 N Tustin Ave -
REV13/7/2025