HomeMy WebLinkAbout415 S Huron Dr - Plan0 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800)994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com TITLE SHEET 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 6 7 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET RACKING CERTIFICATE ATTACHMENT DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V ROOF PLAN MODULE MAP RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV AREA ANZURES 10 1 SOLAR EDGE ENERGY HUB SE6000H-USSNBBL14 (240V) 1 SOLAR EDGE ENERGY BANK BATTERY 10kWh 415 S HURON DR, SANTA ANA, CA 92704 AC Disconnect ACD SSP Service Sub Panel COMPOSITION SHINGLE 1,448 SQFT 10982113 CITY OF SANTA ANA WIRE SIZE CALCULATIONS INVERTER MAP D2 D3 D4 D5 D6 GROUNDING SPECSD7 ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 4.00 KW DC 4.00 KW 3.70 KW AC NEW UPGRADED D8 ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS OPTIMIZER DATA SHEET 1 2 6,534 SQFT 1.1 SITE PLAN Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES IRONRIDGE RACKING TRUSSES 2"X4" @ 24" O.C OCCUPANCY: R ONE STORY BUILDING 200A 200A CANADIAN SOLAR 400W CS6R-400MS-HL (don't delete this note) BATTERY DATA SHEET The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg#: 101118683 Elec#:20182415 Approvals: Elec: MSmith 415 S Huron Dr - 201824154/10/2024 PV 0.0 ROOF PLAN PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com N 0° S 180° E 90° W 270° SCALE 0 51 10ft PHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V) Solar Edge S440 Power Optimizers10 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.00 KW DC 10 Canadian Solar 400W Modules (CS6R-400MS-HL) Gate Gate S H u r o n D r 18'' fire setback 36 ' ' f i r e s e t b a c k MSP SolarEdge Energy Bank Battery INV ACD J/B Solar Array 10 Canadian 400W Modules 10 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 2865 SOLAR AREA (SQ.FT.) - 210 % OF COVERED AREA - 7.3% 415 S Huron Dr - 201824154/10/2024 PV 1.0 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com SITE PLAN N 0° S 180° E 90° W 270° PROPERTY LINE Gate Gate S H u r o n D r Driveway Pu b l i c S i d e w a l k Pu b l i c S i d e w a l k S F a i r v i e w S t 100' 60' 100' 21' 6' 61' 48' 65' MSP INV ACD SCALE 0 51 10ft SolarEdge Energy Bank Battery 415 S Huron Dr - 201824154/10/2024 ATTACHMENT LAYOUT S 1.0 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 22° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 95 MPH SNOW LOAD 0 PSF EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # OPTIMIZERS WEIGHT (LBS) 10 Roof 1 Layer Comp Shingle Ironridge XR10 Truss Stacked 72"2"X4" @ 24" O.C 3 1 2 4 ITEM NO. 1 DESCRIPTION 2 3 4 BOLT LAG 5/16 X 4.75" ASSY, FLASHING ASSY, CAPFOOT WASHER, EPDM BACKED Qty in Kit 4 4 4 4 5/16" X 4.75" Flash Foot 2 MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING 16 210 2865 494 99 15 608 38.0 2.89 7.3 2''X6'' Blocking ASCE 7-16 49.4 CS6R-400MS-HL 72"24" SOLAR MODULE ROOF Max 3.5'' 415 S Huron Dr - 201824154/10/2024 E 1.0 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 5 3 1 4 6 MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY M 2 3 5700W INVERTER PEAK PWR TRACKING VOLTAGE INVERTER EFFICIENCY ENCLOSURE : MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM OUTPUT POWER 4 1 380 V 99.0 % NEMA 4 16.5 A 25.0 A 12,000 W 6,000 W SOLAREDGE ENERGY HUB SE6000H-USSNBBL14 (240V) SOLAREDGE POWER OPTIMIZER RATED DC INPUT POWER MAXIMUM INPUT VOLTAGE MPPT RANGE MAXIMUM SHORT CIRCUIT CURRENT (Isc) MAXIMUM OUTPUT CURRENT OPTIMIZER WEIGHT MAXIMUM POWER PER STRING 5 S440 440W 60 Vdc 8 to 60 Vdc 14.5 Adc 15 Adc 1.5 Lbs 10POWER OPTIMIZER 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 NEW UPGRADED NEW 2 1 33 200A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 INSTALL 2P 40A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 10 Canadian Solar 400W CS6R-400MS-HL Voc = 36.8V Vmp = 30.8V Isc = 13.85A Imp = 12.99A (N)200A 7 (1)#10 AWG (10-12 AWG), 600V insulated (1)#24 AWG (16-24 AWG), 600V insulated or CAT6 1" EMT TYPE Conduit 7 BATTERY BACKUP BATTERY BACKUP SYSTEMS SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 1 String: (10) Modules, (10) Optimizers 415 S Huron Dr - 201824154/10/2024 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com E 1.1 FROM PV MODULES TO JBOX FROM JBOX TO INVERTER (2) WIRE SIZE CALCULATIONS 1 (1) #6 AWG BARE CU EGC, 2 #8 AWG CU EGC, (3) 3 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A) OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A) 1.25 1.25 1.25 0.91 (2) (1) Pmax (PTC Rating) 25.0 380 99.0 % 25.0 * 1.25 / 0.91 34.4 #8 AWG THWN-2 SOLAR EDGE SE6000H-USSNBBL14 (240V) 25.0 * 1.25 31.3 1 1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF ADJST. FACTOR (1 thru 3 WIRES)1.0 FREE IN THE AIR 3/4'' FMT TYPE CONDUIT 1'' EMT TYPE CONDUIT MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 40A */*1.25 *1.2510400 380 16.4 / /16.4 0.58 1.0 28.3 #10 AWG THWN-2 WIRE CHART WIRE CHART *10 400 4.00 KW * *10 373.9 0.99 3.70 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT 200A 200A 240A 200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX FROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING 10 #10 AWG PV-WIRE 10 CS6R-400MS-HL 400 W 373.9 W 400 415 S Huron Dr - 201824154/10/2024 CODE REQUIRED SIGNAGE PV 2.0 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) DC D i s c o n n e c t CEC 690.13(B) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT CEC 690.31(E) CEC 690.54 AC D i s c o n n e c t CEC 690.54 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) PM M E T E R Ma i n / S u b P a n e l CEC 690.54 CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59 CEC 690.15 (B) & CEC 690.33(D)(2) CEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT! CEC 710.15(C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) CEC 705.12 (B)(3)(2) LABELING REQUIREMENTS FOR ARTICLE 690 CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked “PV SYSTEM DISCONNECT” or equivalent. Additional markings shall be permitted based upon the specific system configuration. CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall simultaneously disconnect the PV system conductors that are not solidly grounded from all conductors of other wiring systems. The PV system disconnecting means or its remote operating device or the enclosure providing access to the disconnecting means shall be capable of being locked in accordance with 110.25. CEC 690.15(B) An isolating device shall not be required to have an interrupting rating. Where an isolating device is not rated for interrupting the circuit current, it shall be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An isolating device shall not be required to simultaneously disconnect all current-carrying conductors of a circuit. CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all termination, connection, and splice points by color coding, marking tape, tagging, or other approved means. CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring methods and enclosures that contain PV system dc circuit conductors shall be marked with the wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of permanently affixed labels or other approved permanent marking. CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”. CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors, and inverters shall be considered as internal components of an ac module or ac module system. CEC 690.53 A permanent readily visible label indicating the highest maximum dc voltage in a PV system, calculated in accordance with 690.7, shall be provided by the installer. CEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. CEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. CEC 690.56(A) Plaques or directories shall be installed in accordance with 705.10. CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch. CEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705 and Article 712. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY CFC 1205.4.1(1) & CEC 690.56(C) CEC 690.56(C)(2) CEC 690.31(D)(2) CEC 690.31(D)(2)CO N D U I T RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT DC DISCONNECT PHOTOVOLTAIC WARNING RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT DOWN THE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY, A LABEL SHALL BE PROVIDED. THE FIRST TWO LINES OF THE LABEL SHALL BE UPPERCASE CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A YELLOW BACKGROUND. THE REMAINING CHARACTERS SHALL BE UPPERCASE WITH A MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON A WHITE BACKGROUND. [CFC 1205.4.1(1)] 240 Vac 240 Vac 240 Vac CEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 25.0 A MAX 25.0 A MAX 25.0 A MAX WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 690.53 OF PV SYSTEM MAXIMUM DC VOLTAGE CEC 690.53 MAXIMUM SYSTEM VOLTAGE RATED SHORT CIRCUIT CURRENT N/AMAX RATED AC OPERATING VOLTAGE N/ARATED AC OPERATING VOLTAGE MAX RATED AC OPERATING CURRENT RATED AC OPERATING CURRENT N/A N/A N/A N/A CAUTION N 0° S 180° E 90° W 270° POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CEC 705.10 & CEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION SOLAR INVERTER SOLAREDGE ENERGY BANK BATTERY SOLAR ARRAY ON THE ROOF S H u r o n D r 415 S Huron Dr - 201824154/10/2024 PV 2.1 MODULE MAP PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com [FOR INSTALLER USE ONLY] PHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V) Solar Edge S440 Power Optimizers10 4.00 KW DC 10 Canadian Solar 400W Modules (CS6R-400MS-HL) Solar Array 10 Canadian 400W Modules 10 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg 415 S Huron Dr - 201824154/10/2024 PV 3.0 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com INVERTER MAP INVERTERPHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V) Solar Edge S440 Power Optimizers10 4.00 KW DC [FOR INSTALLER USE ONLY] 10 Canadian Solar 400W Modules (CS6R-400MS-HL) Solar Array 10 Canadian 400W Modules 10 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg 415 S Huron Dr - 201824154/10/2024 PV 3.1 MODULE DATA SHEET PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com 415 S Huron Dr - 201824154/10/2024 INVERTER DATA SHEET PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com PV 4.0 415 S Huron Dr - 201824154/10/2024 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com OPTIMIZER DATA SHEET PV 4.1 415 S Huron Dr - 201824154/10/2024 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com ATTACHMENT SPECIFICATIONS PV 5.1 415 S Huron Dr - 201824154/10/2024 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com PV 6.0 RACKING CERTIFICATE 415 S Huron Dr - 201824154/10/2024 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com PV 6.1 GROUNDING SPECS 415 S Huron Dr - 201824154/10/2024 PV SYSTEM AS INDICATED DECEMBER 19, 2023 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com PV7 BATTERY DATA SHEET 415 S Huron Dr - 201824154/10/2024 Expedited Permit Process for PV Systems 1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 415 S Huron Dr - 201824154/10/2024 Expedited Permit Process for PV Systems 2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 415 S Huron Dr - 201824154/10/2024 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan               Gate Gate S H u r o n D r 18'' fire setback 36 ' ' f i r e s e t b a c k MSP SolarEdge Energy Bank Battery INV ACD J/B Solar Array 10 Canadian 400W Modules 10 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg 415 S Huron Dr - 201824154/10/2024 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                            415 S Huron Dr - 201824154/10/2024 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date:SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THEREQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THEREQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAXCURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTEROCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTALSUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)?YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEANEXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHESTMONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT ATLEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLERFUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLERFUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) 415 S Huron Dr - 201824154/10/2024 •• ••• •• CLEAN ENERGY SOLUTIONS To whom it may concern, Clean Energy Solutions 417 W. Allen Ave Suite #105 San Dimas CA, 91773 800)994-1134 This letter authorizes B ernard Albosta to pull permits/ business license on behalf of Clean Energy Solutions. If you have any question, please call us at 800) 994-1134 Sincerely, David Gomez CEO A notary public or other officer comple�ng this cerlificate verifies only the Identity of the individual who signed lhe document 10 which lhis certificate is attached, and nol the lruthlulness accuracy, or validily of lhat document. State of California County of / f)S �lc.J Subscribe�nd sworn to (or affirmed)beore me on thisl_day of ?:(� ,20 1-!J by � Q-y\<k (-,ol\Jv+;. proved to me on the basis of satisfactory evidence to be the person( who app ared before me. Signature (Nolary Seat) ' @ ANDRE ROBINSONI , r. COMM # 2433203 � :;; NOTARY PUBLIC· CAUFORNIA !'? I LOS ANGELES COUNTY Ilily Com! Ell)ltS JANUARY ll. 2027 q • 0 415 S Huron Dr - 201824154/10/2024 415 S Huron Dr -201824154/10/2024 PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV AREA ANZURES 10 1 SOLAR EDGE ENERGY HUB SE6000H-USSNBBL14 (240V) 1 SOLAR EDGE ENERGY BANK BATTERY 10kWh 415 S HURON DR, SANTA ANA, CA 92704 AC DisconnectACD SSP Service Sub Panel COMPOSITION SHINGLE 1,448 SQFT 10982113 CITY OF SANTA ANA ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 3.95 KW DC 3.95 KW 3.68 KW AC NEW UPGRADED ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS 6,534 SQFT Battery Backup BB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES IRONRIDGE RACKING TRUSSES 2"X4" @ 24" O.C OCCUPANCY: R ONE STORY BUILDING 200A 200A CANADIAN SOLAR 395W CS6R-395MS-HL (don't delete this note) 0 TITLE SHEET SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE E 1.1 PV 2.0 ATTACHMENT LAYOUTS 1.0 PV 2.1 PV 3.0 INVERTER DATA SHEET MODULE DATA SHEET RACKING SPECIFICATIONS ATTACHMENT SPECIFICATIONS ROOF PLAN MODULE MAP WIRE SIZE CALCULATIONS INVERTER MAP GROUNDING SPECIFICATIONS OPTIMIZER DATA SHEET PV 0.0 E 1.0 SITE PLANPV 1.0 PV 3.1 PV 4.0 PV 4.1 PV 5.0 PV 5.1 PV 6.0 PV 6.1 BATTERY DATA SHEET 0 TITLE SHEET The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. REVISION TO: Bldg# 101118683 Elec# 20182415 Bldg# 101119092 Elec# 20182662 APPROVALS: ELEC - MSmith 415 S Huron Dr - 101119092&20182662 REV5/21/2024 ROOF PLAN PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com N 0° S 180° E 90° W 270° SCALE 0 51 10ft PHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V) Solar Edge S440 Power Optimizers10 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT3.95 KW DC 10 Canadian Solar 395W Modules (CS6R-395MS-HL) Gate Gate S H u r o n D r 18'' fire setback 36 ' ' f i r e s e t b a c k MSP SolarEdge Energy Bank Battery INV ACDJ/B Solar Array 1 8 Canadian 395W Modules 8 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 2865 SOLAR AREA (SQ.FT.) - 210 % OF COVERED AREA - 7.3% PV 0.0 36'' fire setback 36'' fire setback 18 ' ' f i r e s e t b a c k Solar Array 2 2 Canadian 395W Modules 2 S440 Optimizers Tilt: 22 Deg Azimuth: 95 Deg 415 S Huron Dr - 101119092&20182662 REV5/21/2024 PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com SITE PLAN N 0° S 180° E 90° W 270° PROPERTY LINE Gate Gate S H u r o n D r Driveway Pu b l i c S i d e w a l k Pu b l i c S i d e w a l k S F a i r v i e w S t 100' 60' 100' 21' 8' 33' 65' MSP INV ACD SCALE 0 51 10ft SolarEdge Energy Bank Battery PV 1.0 40' 415 S Huron Dr - 101119092&20182662 REV5/21/2024 ATTACHMENT LAYOUT PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 22° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 95 MPH SNOW LOAD 0 PSF EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # OPTIMIZERS WEIGHT (LBS) 10 Roof 1 Layer Comp Shingle Ironridge XR10 Truss Stacked 72"2"X4" @ 24" O.C 3 1 2 4 ITEM NO. 1 DESCRIPTION 2 3 4 BOLT LAG 5/16 X 4.75" ASSY, FLASHING ASSY, CAPFOOT WASHER, EPDM BACKED Qty in Kit 4 4 4 4 5/16" X 4.75" Flash Foot 2 MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING 20 210 2865 494 99 15 608 30.4 2.89 7.3 2''X6'' Blocking SOLAR MODULE ROOF ASCE 7-16 Max 3.5'' 49.4 CS6R-395MS-HL S 1.0 72"24" 415 S Huron Dr - 101119092&20182662 REV5/21/2024 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 5 3 1 4 6 MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY M 2 3 5700W INVERTER PEAK PWR TRACKING VOLTAGE INVERTER EFFICIENCY ENCLOSURE : MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM OUTPUT POWER 4 1 380 V 99.0 % NEMA 4 16.5 A 25.0 A 12,000 W 6,000 W SOLAREDGE ENERGY HUB SE6000H-USSNBBL14 (240V) SOLAREDGE POWER OPTIMIZER RATED DC INPUT POWER MAXIMUM INPUT VOLTAGE MPPT RANGE MAXIMUM SHORT CIRCUIT CURRENT (Isc) MAXIMUM OUTPUT CURRENT OPTIMIZER WEIGHT MAXIMUM POWER PER STRING 5 S440 440W 60 Vdc 8 to 60 Vdc 14.5 Adc 15 Adc 1.5 Lbs 10POWER OPTIMIZER 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 NEW UPGRADED NEW 2 1 33 200A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 INSTALL 2P 40A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 10 Canadian Solar 395W CS6R-395MS-HL Voc = 36.6V Vmp = 30.6V Isc = 13.77A Imp = 12.91A (N)200A 7 (1)#10 AWG (10-12 AWG), 600V insulated (1)#24 AWG (16-24 AWG), 600V insulated or CAT6 1" EMT TYPE Conduit 7 BATTERY BACKUP BATTERY BACKUP SYSTEMS SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 1 String: (10) Modules, (10) Optimizers E 1.0 415 S Huron Dr - 101119092&20182662 REV5/21/2024 PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com FROM PV MODULES TO JBOX FROM JBOX TO INVERTER (2) WIRE SIZE CALCULATIONS 1 (1) #6 AWG BARE CU EGC, 2 #8 AWG CU EGC, (3) 3 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A) OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A) 1.25 1.25 1.25 0.91 (2) (1) Pmax (PTC Rating) 25.0 380 99.0 % 25.0 * 1.25 / 0.91 34.4 #8 AWG THWN-2 SOLAR EDGE SE6000H-USSNBBL14 (240V) 25.0 * 1.25 31.3 1 1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF ADJST. FACTOR (1 thru 3 WIRES)1.0 FREE IN THE AIR 3/4'' FMT TYPE CONDUIT 1'' EMT TYPE CONDUIT MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 40A */*1.25 *1.2510395380 16.2 //16.2 0.58 1.0 27.9 #10 AWG THWN-2 WIRE CHART WIRE CHART *10 395 3.95 KW **10 371.9 0.99 3.68 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT 200A 200A 240A 200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX FROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING 10 #10 AWG PV-WIRE 10 CS6R-395MS-HL 395 W 371.9 W 395 E 1.1 415 S Huron Dr - 101119092&20182662 REV5/21/2024 MODULE MAP PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com [FOR INSTALLER USE ONLY] PHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V) Solar Edge S440 Power Optimizers10 3.95 KW DC 10 Canadian Solar 395W Modules (CS6R-395MS-HL) Solar Array 1 8 Canadian 395W Modules 8 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg PV 2.1 Solar Array 2 2 Canadian 395W Modules 2 S440 Optimizers Tilt: 22 Deg Azimuth: 95 Deg 415 S Huron Dr - 101119092&20182662 REV5/21/2024 CODE REQUIRED SIGNAGE PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) DC D i s c o n n e c t CEC 690.13(B) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT CEC 690.31(E) CEC 690.54 AC D i s c o n n e c t CEC 690.54 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) PM M E T E R Ma i n / S u b P a n e l CEC 690.54 CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59 CEC 690.15 (B) & CEC 690.33(D)(2) CEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT! CEC 710.15(C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CEC 110.27(C) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) CEC 705.12 (B)(3)(2) LABELING REQUIREMENTS FOR ARTICLE 690 CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked “PV SYSTEM DISCONNECT” or equivalent. Additional markings shall be permitted based upon the specific system configuration. CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall simultaneously disconnect the PV system conductors that are not solidly grounded from all conductors of other wiring systems. The PV system disconnecting means or its remote operating device or the enclosure providing access to the disconnecting means shall be capable of being locked in accordance with 110.25. CEC 690.15(B) An isolating device shall not be required to have an interrupting rating. Where an isolating device is not rated for interrupting the circuit current, it shall be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An isolating device shall not be required to simultaneously disconnect all current-carrying conductors of a circuit. CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all termination, connection, and splice points by color coding, marking tape, tagging, or other approved means. CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring methods and enclosures that contain PV system dc circuit conductors shall be marked with the wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of permanently affixed labels or other approved permanent marking. CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”. CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors, and inverters shall be considered as internal components of an ac module or ac module system. CEC 690.53 A permanent readily visible label indicating the highest maximum dc voltage in a PV system, calculated in accordance with 690.7, shall be provided by the installer. CEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. CEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. CEC 690.56(A) Plaques or directories shall be installed in accordance with 705.10. CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch. CEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705 and Article 712. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY CFC 1205.4.1(1) & CEC 690.56(C) CEC 690.56(C)(2) CEC 690.31(D)(2) CEC 690.31(D)(2)CO N D U I T RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT DC DISCONNECT PHOTOVOLTAIC WARNING RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT DOWN THE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY, A LABEL SHALL BE PROVIDED. THE FIRST TWO LINES OF THE LABEL SHALL BE UPPERCASE CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A YELLOW BACKGROUND. THE REMAINING CHARACTERS SHALL BE UPPERCASE WITH A MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON A WHITE BACKGROUND. [CFC 1205.4.1(1)] 240 Vac 240 Vac 240 Vac CEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 25.0 A MAX 25.0 A MAX 25.0 A MAX WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.13(B) CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 705.10 CAUTION MULTIPLE SOURCES OF POWER CEC 690.53 OF PV SYSTEM MAXIMUM DC VOLTAGE CEC 690.53 MAXIMUM SYSTEM VOLTAGE RATED SHORT CIRCUIT CURRENT N/AMAX RATED AC OPERATING VOLTAGE N/ARATED AC OPERATING VOLTAGE MAX RATED AC OPERATING CURRENT RATED AC OPERATING CURRENT N/A N/A N/A N/A CAUTION N 0° S 180° E 90° W 270° POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CEC 705.10 & CEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION SOLAR INVERTER SOLAREDGE ENERGY BANK BATTERY SOLAR ARRAY ON THE ROOF S H u r o n D r PV 2.0 415 S Huron Dr - 101119092&20182662 REV5/21/2024 PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com INVERTER MAP INVERTERPHOTOVOLTAIC SYSTEM 1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V) Solar Edge S440 Power Optimizers10 3.95 KW DC [FOR INSTALLER USE ONLY] 10 Canadian Solar 395W Modules (CS6R-395MS-HL) PV 3.0 Solar Array 1 8 Canadian 395W Modules 8 S440 Optimizers Tilt: 22 Deg Azimuth: 185 Deg Solar Array 2 2 Canadian 395W Modules 2 S440 Optimizers Tilt: 22 Deg Azimuth: 95 Deg 415 S Huron Dr - 101119092&20182662 REV5/21/2024 MODULE DATA SHEET PV SYSTEM AS INDICATED APRIL 22, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com PV 3.1 415 S Huron Dr - 101119092&20182662 REV5/21/2024 415 S. HURON DR. SANTA ANA, CA 92704 ANZURES, AREA Design Criteria 1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16 2 - Wind: 95 MPH, Exposure: C 3 - Wood Species: DF-L No. 1 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. 1-844-PV ELITE | info@yoursolarplans.com 3000 E. Birch Street Suite 201 | Brea CA 92821 4/26/2024 Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: Job: 415 S Huron Dr - 101119092&20182662 REV5/21/2024     !"#$%&'( $)%'%*+(,$&-. /0 . 0  '%&0 1.  2 ,,,,3,,"  ",,4,,"3,,56 ,  ",,",, . 7%)8" 9:;<=>?@AB<C;DEB@&-. /.  '%&1. I %&')%'%*+%3)) +-&PI T**\%\%%\+\Z +'\ZZ '-\ZZZ \Z]*\ F9JKUVW^ YZ)[,%\ YZ-)[,%'\ YZ-)[,+-\ YZ)[,'\Y5 , Z \Y5 , ZZ \Y5 , ZZZ)Z]-\ F9JKUV^_ . 7%)-T.,,+-\ jhklgbjabcbmnon`cbpfbkgliqdglgbrcfrklflsbijsbigdgrgabtlfebdrcliqjbfhiblghrifhibdsljbjechiugabvehfjhiukrjbljrwghriwcrkbddxydbcddarefjkriphcsliqbjpcrsgahdgrrfzhgagabfrklf{egarchgq|lthiu}echdjhkghrivbprcbwcrkbbjhiuzhgajbdhuixgalggab{`|l€lcjdvq rklghrizbvdhgbzhffirgvbewjlgbjgrdewwrcg{‚ƒ„…††x‡hijregzaqx,,,3\‰, . 7%,,,,",, ,4, . 7%,,,,,,3,,Š\,,",,",‹,,",,,,3,‰,",,  ,Œ 7,"),,, ,,, ,,\,‰, "\33,",,,,,""),,,  ,,\,,", ,,‹\,3"\,,,",,,,‰,,, \,,3 ,\,,,,,,,,3,3"\,,,‹\‰,33, ,,,, ,,,,33\,,,  \,3\,,3,‰ ,‹,,,5", ,,3,3,3,3,,Ž,33,,,  ,,3,,‰,",,1,3,3\3\\, 3\,1,3,3",,,\‰, ‰,  ,,,,3 ,‰3, ,,,, ,,, U AD 415 S Huron Dr - 101119092&20182662 REV5/21/2024 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope =22 ° Roof Shape Gable Tributary Width s =6.00 ft Tributary Length l =2.83 ft Effective Area Ae =11.15 f 2 Height of Structure h =15 ft Wind Speed V =95 mph Exposure Categor C Building Width B =25 ft Building Length L =55 ft Zone Width a =3 ft Elevation Height zg =73 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.63 psf Solar Array Pressure Equalization a =0.79 Array Edge Factor E =1.50 Zone GCp p = qz(GCp)(E)(a) 3 - - 3r 3.32 -65.82 3e 2.49 -49.35 2 - - 2r 2.49 -49.35 2e - - 2n 2.49 -49.35 1 - - 1' - - 415 S Huron Dr - 101119092&20182662 REV5/21/2024 LAG SCREW ANALYSIS Loads Wind Pressures qz =-49.35 psf Solar Panel Load QD =3 psf Panel Length l =5.650 ft Panel Width b 3.7167 ft Attachment Spacing s =6 ft Portrait Tributary Area At =16.95 ft2 Wind Load PW = qz * At =-836 lbs Dead Load PD = QD * At =50.85 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-471 lbs Landscape Tributary Area At = b * s =11.15 ft2 Wind Load PW = qz * At =-550 lbs Dead Load PD = QD * At =33.45 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-310 lbs Lag Screw Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch) Diameter of Lag Screw D =5/16 in Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in Depth of Embedment lp =2.50 in Total Nominal Withdrawal Value W = W * l p =665 lbs Load Duration Factor CD =1.6 Withdrawal Design Value W' = W * C D =1064 lbs Demand Capacity Ratio DCR = Pa / W'=0.44 < 1 OK 415 S Huron Dr - 101119092&20182662 REV5/21/2024 ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check Roof Slope =22 ° Roof Shape Gable Tributary Width s =2.00 ft Tributary Length L =14.50 ft Effective Area A = L ( MAX [ s , L/3] )=70 f 2 Height of Structure h =15 ft Wind Speed V =95 mph Exposure Categor C Building Width B =25 ft Building Length L =55 ft Zone Width a =3 ft Elevation Height zg =73 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.63 psf Internal Pressure Coefficient (GCpi)=-0.18 Zone GCp p = qz [(GCp) - (Gcpi)] 3 - - 3r 1.80 -32.92 3e 1.94 -35.28 2 - - 2r 1.94 -35.28 2e - - 2n 1.94 -35.28 1 - - 1' - - 415 S Huron Dr - 101119092&20182662 REV5/21/2024 Beam/ Top Chord Check Lumber: Moment Demand # of Attachment per Rafter NA =Span :Orientation Lenght (ft) : Dead Load Roof Material:QD =psf Live Load QLr =psf Wind Load p = psf Snow Load QS =psf Rafter Spacing s = in Wind Load, Portrait Portrait UL = Wind Load, Landscape Landscape UW = Linear Dead Load wd =plf Live Load wLr = plf Start ft Start ft End ft End ft Snow Load ws = plf Start ft Start ft End ft End ft Ma, Moment D lb-ft D+Lr lb-ft D+S lb-ft 0.6D+0.6W lb-ft D+0.45W+0.75Lr lb-ft D+0.45W+0.75S lb-ft Moment Capacity Framing Member Size Lumber Grade : DF-L No. 1 CM = 1 Ct = 1 Cr= CF = fb =psi Cfu =Ci = Breadth b = in Depth d = in Section Modulus Sx = bd2 / 6 =in3 Bending Stress Capacity Fb = CM * Ct * Cr * CF * fb =psi Table 4.3.1 NDS 2015 Deflection Limit E = ksi I =in4 Transient Deflection in Transient Deflection Allowed > [OKAY] Total Deflection in Total Deflection Allowed > [OKAY] -35.28 DF-L No. 1 4 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs) Portrait 1 2.2 50.9 -598 0.0 6.4 50.9 -598 -393 0.0 4 10.2 33.5 -393 0.0 0.0 5.50 8.00 0.00 0.00 1.00 Landscape 3 7.9 33.5 10.00 1 2 3 4 Eave 2 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0 0.0Portrait0 0.0 0.0 0 0.0 20 40 0.0 0.0 0.0 0.0 0 0.0Portrait0 0.033.45 -393 0 0 0.0 0 1.5 0 0 0.0 Portrait 1.5 0.0Portrait0 0.0 0.0 AT (ft2) 16.95 11.15 pd (lbs) 50.85 -598 pw (lbs) ps (lbs) 0 10.87 2x4 1.15 1.5 14.50 10.87 14.50 1000 1.50 3.50 218 239 218 553 295 295 DCR 0.9 1553 psi D 854 psi 0.55 3.06 1725 CD Fb' = CD * Fb ASD Load Ma / Sx 1.15 1984 psi D+S 854 psi 0.43 OKAY OKAY 1.25 2156 psi D+Lr 935 psi 0.43 OKAY 1.6 2760 psi 0.446 215 120 1700 5.36 0.6D+0.6W 2168 psi 0.79 OKAY 1.0 1 20 0.00 24 Comp 0.388 247 180 1.6 2760 psi D+0.45W+0.75S 1156 psi 0.42 OKAY 1.6 2760 psi D+0.45W+0.75L 1156 psi 0.42 OKAY 𝑴𝒙 𝑹𝒊𝒙 𝑳𝒊 𝑷𝒋𝒙 𝒍𝒋 𝒘𝒅𝒙𝟐 𝟐 ‐800.0 ‐600.0 ‐400.0 ‐200.0 0.0 200.0 400.0 600.0 0.000 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000 415 S Huron Dr - 101119092&20182662 REV5/21/2024 EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model CS Panel Weight W panel = 49.4 lbs Number of Panels NPV = 10 Total PV System Weight W PV = W panel * NPV =494 lbs Existing Roof Weight Roof Weight QD =10.0 psf Building Length Lbuild =55 ft Building Width W build =25 ft Roof Area Abuild =1375 ft2 Building Perimeter Pbuild =160 ft Wall Height ht =8 ft Wall weight Qwall =15 psf Interior wall weight Qint =10 psf Roof Load W floor = Abuild * QD =13750 lbs Wall Load wall = ht /2 * Qwall * Pbuild + Abuild * Qint /=16475 lbs Total Story Weight W build = W floor + W wall =30225 lbs Percentage Weight Increas WPV / Wbuild = 1.63% < 10% OKAY 415 S Huron Dr - 101119092&20182662 REV5/21/2024 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED JULY 12, 2024 AREA ANZURES 415 S HURON DR, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 5 3 1 4 6 MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY M 2 3 5700W INVERTER PEAK PWR TRACKING VOLTAGE INVERTER EFFICIENCY ENCLOSURE : MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM OUTPUT POWER 4 1 380 V 99.0 % NEMA 4 16.5 A 25.0 A 12,000 W 6,000 W SOLAREDGE ENERGY HUB SE6000H-USSNBBL14 (240V) SOLAREDGE POWER OPTIMIZER RATED DC INPUT POWER MAXIMUM INPUT VOLTAGE MPPT RANGE MAXIMUM SHORT CIRCUIT CURRENT (Isc) MAXIMUM OUTPUT CURRENT OPTIMIZER WEIGHT MAXIMUM POWER PER STRING 5 S440 440W 60 Vdc 8 to 60 Vdc 14.5 Adc 15 Adc 1.5 Lbs 10POWER OPTIMIZER 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 NEW UPGRADED NEW 2 1 33 200A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 INSTALL 2P 40A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 10 Canadian Solar 395W CS6R-395MS-HL Voc = 36.6V Vmp = 30.6V Isc = 13.77A Imp = 12.91A (N)200A 7 (1)#10 AWG (10-12 AWG), 600V insulated (1)#24 AWG (16-24 AWG), 600V insulated or CAT6 3/4" EMT TYPE Conduit 7 BATTERY BACKUP BATTERY BACKUP SYSTEMS SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 1 String: (10) Modules, (10) Optimizers E 1.0 Elec#: 20183568 Revision to: Elec#: 20182415 & 20182662 Approvals: Elec: M Smith ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** 415 S Huron Dr 8/23/2024 Thank you, Clean Energy Solutions Inc. 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994-1134 To: City of Santa Ana Project name: Area Anzures Project Address: 415 S Huron Dr, Santa Ana, CA 92704 RESPONSE SHEET • The conduit size running from the inverter to the battery has been changed. (Page E 1.0) 415 S Huron Dr 8/23/2024 PCC-13 Rev. 06-17-2019 White-Plan Check Yellow-Applicant REVISION /SUPPLEMENTAL PLAN CHECK REQUEST PCC-13 CBC 2022 Rev 6-17-2024 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Project Address: _________________________________________ Suite #_______________________________ New Plan Check No.____________________________________________________________________________ Original Plan Check No.:__________________________________ Permit Issuance Date:____________________ Original Plan Checker: __________________________________________________________________________ Amount Paid: $__________________________________________ Misc. Receipt #: ________________________ Processed by: ___________________________________________ Date: ________________________________ Additional Hours:________________________________________ @ $269.90 = $ _________________________ Print Name:_____________________________________________ Signature: ____________________________ Representing: ________________________________________________________________________________ E-mail (Strongly Recommended): _________________________________________________________________ PLANS PREPARED BY AN ARCHITECT OR ENGINEER MUST BE SIGNED BY THE PROFESSIONAL WHO PREPARES THEM. PLEASE WRITE A BRIEF DESCRIPTION OF THE REVISION/SUPPLEMENT AND IF POSSIBLE AREA OF WORK. ALL REVISIONS ARE TO BE CLOUDED AND PROPERLY IDENTIFIED: (i.e. Deltas,Sheet Numbers, etc.). Electrical, Plumbing and/or Mechanical plans – stamped job set shall accompany revised plans. ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ Telephone: (800 ) ____________________________________ Fax: ( ) __________________________________ Contact Person: ________________________________________ Telephone: (800 ) ________________________ Plan Checker Approval: ___________________________________ Date: ________________________________ 415 S Huron Dr Santa Ana, CA 92704 101118683 4/10/2024 Smith, Mark $240.54 Melissa Luna Clean Energy Solutions 994-1134 Melissa Luna 994-1134 mluna@cleanenergysolutions.org The conduit size running from the inverter to the battery has been changed. (Page E 1.0) 415 S Huron Dr 8/23/2024