PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800)994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
TITLE SHEET
1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE
COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY
2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED
3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED
4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER.
5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING
COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED.
6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY
AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL
INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY.
7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE
COORDINATED WITH OTHER TRADES.
8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS
RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT.
9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE
WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE.
10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE
SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS.
OWNER
SCOPE
PROJECT
ADDRESS
PROJECT DATA GENERAL NOTES VICINITY MAP
SHEET INDEX
0 COVER PAGE
PHOTOVOLTAIC NOTES
SATELLITE VIEW
BUILDING
INFORMATION:
SINGLE LINE DIAGRAM
CODE REQUIRED SIGNAGE
3
4
ATTACHMENT LAYOUT5
6
7
INVERTER DATA SHEET
D1 MODULE DATA SHEET
RACKING DATA SHEET
RACKING CERTIFICATE
ATTACHMENT DATA SHEET
ELECTRICAL
INFORMATION
MAIN SERVICE PANEL
BUSBAR RATING
MAIN SERVICE
BREAKER RATING
1ɸ, 3W, 120/240V
ROOF PLAN
MODULE MAP
RACKING
INFORMATION
Main Service Panel
Solar Module
Micro Inverter /
Optimizer
EMT / FMT / PVC
/ RMC type conduit/
Romex NM Cable/
FNMT (Fluid non-metalic tube)
36'' SetbackInverter
Utility Meter
Production Meter
PV Load Center
IQ Combiner Box
Junction Box
Sunpower PV Supervisor
18'' Setback
EV Outlet
CONSTRUCTION TYPE: V-B
ROOF
TYPE
AHJ
APN
LOT AREA
LIVING AREA
MSP
UM
PM
INV
PV
PVS6
IQ
J/B
EV
AREA ANZURES
10
1 SOLAR EDGE ENERGY HUB SE6000H-USSNBBL14 (240V)
1 SOLAR EDGE ENERGY BANK BATTERY 10kWh
415 S HURON DR,
SANTA ANA, CA 92704
AC Disconnect ACD
SSP Service Sub Panel
COMPOSITION SHINGLE
1,448 SQFT
10982113
CITY OF SANTA ANA
WIRE SIZE CALCULATIONS
INVERTER MAP
D2
D3
D4
D5
D6
GROUNDING SPECSD7
ROOF MOUNT INSTALLATION OF
DC PHOTOVOLTAIC SYSTEM
4.00 KW DC
4.00 KW
3.70 KW AC
NEW UPGRADED
D8
ALL OTHER ORDINANCE ADOPTED BY THE
LOCAL GOVERNING AGENCIES
THE INSTALLATION OF SOLAR ARRAYS AND
PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY
WITH THE FOLLOWING CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
2022 CALIFORNIA HISTORICAL CODE
2022 CALIFORNIA EXISTING BUILDING CODE
2022 CALIFORNIA REFERENCED STANDARDS CODE
2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE
1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703.
2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS
3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED.
4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER
OUTAGE.
5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING
ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS.
6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE.
7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE
ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED.
8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION
9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED
10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT.
11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING
MEANS AS PER 230.82(6)
12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING
AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122
13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122.
14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS
OPTIMIZER DATA SHEET
1
2
6,534 SQFT 1.1 SITE PLAN
Battery BackupBB
Auto TransformerAT
Solar Edge Meter EnclosureSEM
Distribution PanelDP
Rapid Shutdown Controller RSC
Rapid Shutdown Box RSB
Itron MeterIM
UNIT INDEX
CODE REFERENCES
IRONRIDGE RACKING
TRUSSES 2"X4" @ 24" O.C
OCCUPANCY: R
ONE STORY BUILDING
200A
200A
CANADIAN SOLAR 400W
CS6R-400MS-HL
(don't delete this note)
BATTERY DATA SHEET
The scope of the plans is for the
installation of the solar photovoltaic
system only and the approval is
subject to compliance with all
applicable city and state codes and
regulations regarding construction.
The approval of the plans does not
constitute any certification of the
accuracy, completeness, or building
permit status of the existing buildings
and structures as shown.
Bldg#: 101118683
Elec#:20182415
Approvals:
Elec: MSmith
415 S Huron Dr -
201824154/10/2024
PV 0.0
ROOF PLAN
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
N
0°
S
180°
E
90°
W
270°
SCALE
0 51 10ft
PHOTOVOLTAIC SYSTEM
1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V)
Solar Edge S440 Power Optimizers10
FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER
THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.00 KW DC
10 Canadian Solar 400W Modules (CS6R-400MS-HL)
Gate
Gate
S
H
u
r
o
n
D
r
18'' fire setback
36
'
'
f
i
r
e
s
e
t
b
a
c
k
MSP
SolarEdge Energy Bank Battery
INV
ACD
J/B
Solar Array
10 Canadian 400W Modules
10 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
ROOF AREA CALCULATIONS
FIRE SPRINKLERS - NO
TOTAL ROOF AREA (SQ.FT.) - 2865
SOLAR AREA (SQ.FT.) - 210
% OF COVERED AREA - 7.3%
415 S Huron Dr -
201824154/10/2024
PV 1.0
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
SITE PLAN
N
0°
S
180°
E
90°
W
270°
PROPERTY LINE
Gate
Gate
S
H
u
r
o
n
D
r
Driveway
Pu
b
l
i
c
S
i
d
e
w
a
l
k
Pu
b
l
i
c
S
i
d
e
w
a
l
k
S
F
a
i
r
v
i
e
w
S
t
100'
60'
100'
21'
6'
61'
48'
65'
MSP
INV
ACD
SCALE
0 51 10ft
SolarEdge Energy Bank Battery
415 S Huron Dr -
201824154/10/2024
ATTACHMENT
LAYOUT
S 1.0
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
STRUCTURAL STAMPROOF
PITCH
ROOFING
TYPE
ATTACHMENT
TYPE
FRAMING
TYPE
FRAMING
SIZE
PENETRATION
PATTERN
22°
RACKING
TYPE
MAX
PENETRATION
SPACING
ROOFING
LAYERS
WIND SPEED 95 MPH
SNOW LOAD 0 PSF
EXPOSURE C
LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE
SEALED WITH CHEM LINK SEALANT OR EQUIVALENT.
MODULE WEIGHT (LBS)
# OF MODULES
TOTAL MODULE WEIGHT (LBS)
RACK WEIGHT (LBS)
TOTAL SYSTEM WEIGHT (LBS)
# OF STANDOFFS
LOADING PER STANDOFF (LBS)
TOTAL MODULE AREA (SQ.FT.)
LOADING (PSF)
WEIGHT LOAD CALCULATION INDEX
ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER
SURFACE IS FACED WITH FELT PAPER
TOTAL ROOF AREA (Sq. FT)
% OF COVERED AREA
PV MODULE MODEL #
OPTIMIZERS WEIGHT (LBS)
10
Roof 1 Layer Comp Shingle Ironridge XR10 Truss Stacked 72"2"X4" @ 24" O.C
3
1
2
4
ITEM NO.
1
DESCRIPTION
2
3
4
BOLT LAG 5/16 X 4.75"
ASSY, FLASHING
ASSY, CAPFOOT
WASHER, EPDM BACKED
Qty in Kit
4
4
4
4
5/16" X 4.75"
Flash Foot 2
MIN 2.5" EMBEDMENT
RACKING RAIL
ATTACHMENT
ROOF FRAMING
16
210
2865
494
99
15
608
38.0
2.89
7.3
2''X6'' Blocking
ASCE 7-16
49.4
CS6R-400MS-HL
72"24"
SOLAR MODULE
ROOF
Max 3.5''
415 S Huron Dr -
201824154/10/2024
E 1.0
SINGLE LINE
DIAGRAM
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
ITEM DESCRIPTION QTY#
PV MODULE
MAIN SERVICE PANEL
MAIN SERVICE PANEL
& UTILITY METER
BUSBAR RATING
BREAKER RATING
1
ITEM DESCRIPTION QTY#
PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3
1
1
1
5
3
1
4
6
MAIN
SERVICE
PANEL
120/240V
1P,3W
2
EXISTING
GROUNDING SYSTEM
UTILITY
M
2
3
5700W
INVERTER
PEAK PWR TRACKING VOLTAGE
INVERTER EFFICIENCY
ENCLOSURE :
MAXIMUM INPUT CURRENT
MAXIMUM OUTPUT CURRENT
MAXIMUM INPUT POWER
MAXIMUM OUTPUT POWER
4 1
380 V
99.0 %
NEMA 4
16.5 A
25.0 A
12,000 W
6,000 W
SOLAREDGE ENERGY HUB SE6000H-USSNBBL14 (240V)
SOLAREDGE POWER OPTIMIZER
RATED DC INPUT POWER
MAXIMUM INPUT VOLTAGE
MPPT RANGE
MAXIMUM SHORT CIRCUIT CURRENT (Isc)
MAXIMUM OUTPUT CURRENT
OPTIMIZER WEIGHT
MAXIMUM POWER PER STRING
5
S440
440W
60 Vdc
8 to 60 Vdc
14.5 Adc
15 Adc
1.5 Lbs
10POWER OPTIMIZER
60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE,
BLADE TYPE, NEMA 3R, 120/240V 16
NEW UPGRADED
NEW
2
1
33
200A
200A
200A
FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3
INSTALL 2P
40A CB(PV) AT
OPPOSITE END
OF BUS FROM
MAIN FEEDER CB
10
Canadian Solar 400W
CS6R-400MS-HL
Voc = 36.8V
Vmp = 30.8V
Isc = 13.85A
Imp = 12.99A
(N)200A
7
(1)#10 AWG (10-12 AWG), 600V insulated
(1)#24 AWG (16-24 AWG), 600V insulated or CAT6
1" EMT TYPE Conduit
7 BATTERY BACKUP BATTERY BACKUP SYSTEMS
SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 1
String: (10) Modules, (10) Optimizers
415 S Huron Dr -
201824154/10/2024
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
E 1.1
FROM PV MODULES TO JBOX
FROM JBOX TO INVERTER
(2)
WIRE SIZE
CALCULATIONS
1
(1) #6 AWG BARE CU EGC,
2
#8 AWG CU EGC,
(3)
3
(1) #8 AWG CU EGC,
MAXIMUM INVERTER OUTPUT CURRENT (A)
TEMPERATURE FACTOR
TEMPERATURE ADJUSTMENT (A)
OUTPUT CALCULATIONS
PV SYSTEM MAX DC OUTPUT
PV SYSTEM MAX AC OUTPUT
MAXIMUM POWER (W)
PEAK PWR TRACKING VOLTAGE (V)
CONSIDER CONTINUOUS COEFFICIENT
SHORT CIRCUIT CURRENT (A)
ADJUSTED CONDUCTOR AMPACITY (A)
1.25
1.25
1.25
0.91
(2)
(1)
Pmax (PTC Rating)
25.0
380
99.0 %
25.0 * 1.25 / 0.91 34.4
#8 AWG THWN-2
SOLAR EDGE SE6000H-USSNBBL14 (240V)
25.0 * 1.25 31.3
1
1 1/2''
(TEMP - 39 + 22 = 61C)0.58
RACEWAY HEIGHT FROM ROOF
ADJST. FACTOR (1 thru 3 WIRES)1.0
FREE IN THE AIR
3/4'' FMT TYPE CONDUIT
1'' EMT TYPE CONDUIT
MAIN SERVICE PANEL RATING
BUSBAR RATING
MAIN BREAKER
PV BACKFEED BREAKER SIZE
120% RULE:
MAX ALLOWED FEED
40A
*/*1.25 *1.2510400 380 16.4
/ /16.4 0.58 1.0 28.3
#10 AWG THWN-2
WIRE CHART WIRE CHART
*10 400 4.00 KW
* *10 373.9 0.99 3.70 KW
CONSIDER CONTINUOUS COEFFICIENT
CONSIDER CONTINUOUS COEFFICIENT
200A
200A
240A
200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX
FROM INVERTER TO MAIN SERVICE PANEL
CONSIDER CONTINUOUS (A)
MAX NUMBER OF MODULES IN STRING 10
#10 AWG PV-WIRE
10
CS6R-400MS-HL 400 W
373.9 W
400
415 S Huron Dr -
201824154/10/2024
CODE REQUIRED
SIGNAGE
PV 2.0
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
JB
B
O
X
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
CEC 110.27(C)
DC
D
i
s
c
o
n
n
e
c
t
CEC 690.13(B)
In
v
e
r
t
e
r
/
P
V
L
o
a
d
WARNING
THE DISCONNECTION OF THE
GROUNDING CONDUCTOR(S)
MAY RESULT IN OVERVOLTAGE
ON THE EQUIPMENT
CEC 690.31(E)
CEC 690.54
AC
D
i
s
c
o
n
n
e
c
t
CEC 690.54
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
PM
M
E
T
E
R
Ma
i
n
/
S
u
b
P
a
n
e
l
CEC 690.54
CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59
CEC 690.15 (B) & CEC 690.33(D)(2)
CEC 690.13(B)
SINGLE 120-VOLT SUPPLY
DO NOT CONNECT
MULTIWIRE BRANCH CIRCUIT!
CEC 710.15(C)
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
CEC 110.27(C)
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
CEC 705.12 (B)(3)(2)
LABELING REQUIREMENTS FOR ARTICLE 690
CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether
in the open (off) or closed (on) position and be permanently marked “PV SYSTEM
DISCONNECT” or equivalent. Additional markings shall be permitted based upon
the specific system configuration.
CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall
simultaneously disconnect the PV system conductors that are not solidly grounded
from all conductors of other wiring systems. The PV system disconnecting means or
its remote operating device or the enclosure providing access to the disconnecting
means shall be capable of being locked in accordance with 110.25.
CEC 690.15(B) An isolating device shall not be required to have an interrupting
rating. Where an isolating device is not rated for interrupting the circuit current, it shall
be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An
isolating device shall not be required to simultaneously disconnect all current-carrying
conductors of a circuit.
CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all
termination, connection, and splice points by color coding, marking tape, tagging, or
other approved means.
CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring
methods and enclosures that contain PV system dc circuit conductors shall be marked with the
wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of
permanently affixed labels or other approved permanent marking.
CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring
system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between
labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft).
Labels required in this section shall be suitable for the environment where they are installed.
CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a
permanent, legible warning notice indicating that the disconnection of the grounded
conductor(s) may result in overvoltage on the equipment.
CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a
tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”.
CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors,
and inverters shall be considered as internal components of an ac module or ac module
system.
CEC 690.53 A permanent readily visible label indicating the highest
maximum dc voltage in a PV system, calculated in accordance with 690.7,
shall be provided by the installer.
CEC 690.54 All interactive system(s) points of interconnection with other
sources shall be marked at an accessible location at the disconnecting
means as a power source and with the rated ac output current and the
nominal operating ac voltage.
CEC 690.55 The PV system output circuit conductors shall be marked to
indicate polarity where connected to energy storage systems.
CEC 690.56(A) Plaques or directories shall be installed in accordance with
705.10.
CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on
or no more than 1 meter (3 ft) from the switch.
CEC 690.59 PV systems connected to other sources shall be installed in
accordance with Parts I and II of Article 705 and Article 712.
SOLAR ELECTRIC
PV PANELS
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH ON THE
"OFF" POSITION TO
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN ARRAY
CFC 1205.4.1(1) & CEC 690.56(C)
CEC 690.56(C)(2)
CEC 690.31(D)(2)
CEC 690.31(D)(2)CO
N
D
U
I
T
RATED AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT
DC DISCONNECT
PHOTOVOLTAIC
WARNING
RATED AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT
RATED AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT WARNING
CAUTION
PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED
WARNING
POWER SOURCE OUTPUT
CONNECTION. DO NOT
RELOCATE THIS
OVERCURRENT DEVICE.
WARNING
DO NOT DISCONNECT
UNDER LOAD
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING
PHOTOVOLTAIC POWER SOURCE
DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW
FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT
DOWN THE ARRAY AND THE CONDUCTORS LEAVING
THE ARRAY, A LABEL SHALL BE PROVIDED. THE
FIRST TWO LINES OF THE LABEL SHALL BE
UPPERCASE CHARACTERS WITH A MINIMUM
HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A
YELLOW BACKGROUND. THE REMAINING
CHARACTERS SHALL BE UPPERCASE WITH A
MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON
A WHITE BACKGROUND. [CFC 1205.4.1(1)]
240 Vac
240 Vac
240 Vac
CEC 690.13(B)
AC DISCONNECT
PHOTOVOLTAIC
25.0 A MAX
25.0 A MAX
25.0 A MAX
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
CEC 705.10
CAUTION
MULTIPLE SOURCES OF POWER
CEC 705.10
CAUTION
MULTIPLE SOURCES OF POWER
CEC 690.53
OF PV SYSTEM
MAXIMUM DC VOLTAGE
CEC 690.53
MAXIMUM SYSTEM VOLTAGE
RATED SHORT CIRCUIT CURRENT
N/AMAX RATED AC OPERATING VOLTAGE
N/ARATED AC OPERATING VOLTAGE
MAX RATED AC OPERATING CURRENT
RATED AC OPERATING CURRENT
N/A
N/A
N/A
N/A
CAUTION
N
0°
S
180°
E
90°
W
270°
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN:
CEC 705.10 & CEC 690.56(B)
Permanent directory or plaque providing location of service disconnecting means and
photovoltaic system disconnecting means, if not located at the same location. (Plaques shall
be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a
contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the
required location using an approved method that is suitable to withstand the environment to which it
is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion
requirements of Underwriters Laboratories marking and labeling system 969(UL969).
Plaques will have red background & white lettering.
SERVICE POINT &
UTILITY METERING
PV SYSTEM DISCONNECT
FOR UTILITY OPERATION
SOLAR INVERTER
SOLAREDGE ENERGY
BANK BATTERY
SOLAR ARRAY
ON THE ROOF
S
H
u
r
o
n
D
r
415 S Huron Dr -
201824154/10/2024
PV 2.1
MODULE
MAP
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
[FOR INSTALLER USE ONLY]
PHOTOVOLTAIC SYSTEM
1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V)
Solar Edge S440 Power Optimizers10
4.00 KW DC
10 Canadian Solar 400W Modules (CS6R-400MS-HL)
Solar Array
10 Canadian 400W Modules
10 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
415 S Huron Dr -
201824154/10/2024
PV 3.0
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
INVERTER
MAP
INVERTERPHOTOVOLTAIC SYSTEM
1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V)
Solar Edge S440 Power Optimizers10
4.00 KW DC
[FOR INSTALLER USE ONLY]
10 Canadian Solar 400W Modules (CS6R-400MS-HL)
Solar Array
10 Canadian 400W Modules
10 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
415 S Huron Dr -
201824154/10/2024
PV 3.1
MODULE
DATA SHEET
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
415 S Huron Dr -
201824154/10/2024
INVERTER
DATA SHEET
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
PV 4.0
415 S Huron Dr -
201824154/10/2024
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
OPTIMIZER
DATA SHEET
PV 4.1
415 S Huron Dr -
201824154/10/2024
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
ATTACHMENT
SPECIFICATIONS
PV 5.1
415 S Huron Dr -
201824154/10/2024
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
PV 6.0
RACKING
CERTIFICATE
415 S Huron Dr -
201824154/10/2024
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
PV 6.1
GROUNDING
SPECS
415 S Huron Dr -
201824154/10/2024
PV SYSTEM
AS INDICATED
DECEMBER 19, 2023
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
PV7
BATTERY
DATA SHEET
415 S Huron Dr -
201824154/10/2024
Expedited Permit Process for PV Systems 1
Expedited Permit Process for PV Systems
Standard String System
The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro-
cess provides a means to differentiate systems that can be permitted quickly and easily
due to their similarity with the majority of small-scale PV systems. Those systems with
unique characteristics may be handled with small additions to this Expedited Permit
Process or may require much more information, depending on the uniqueness of the
installation.
The following pages contain forms for the Standard String System to use with the Expe-
dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms
are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic-
tions that have adopted the Expedited Permit Process for PV Systems, these forms can
be filled out electronically and submitted in either printed form and via email. An elec-
tronic format is used so that the supplied information is standardized and legible for the
local jurisdiction.
415 S Huron Dr -
201824154/10/2024
Expedited Permit Process for PV Systems 2
Expedited Permit Process for Small-Scale PV Systems
Standard String System
The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations
are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential
systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been
suggested to provide as a path to permit approval.
Required Information for Permit:
1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it
should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings
with a 3’ perimeter space at ridge and sides may not need separate fire service review.
2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects,
required signs, and ac connection to building (see supplied standard electrical diagram).
3. Specification sheets and installation manuals (if available) for all manufactured components including, but not
limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system.
Step 1: Structural Review of PV Array Mounting System
Is the array to be mounted on a defined, permitted roof structure? l Yes l No
If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1.
Roof Information:
1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________
____________________________________________________________________________________________________
If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…).
2. Does the roof have a single roof covering? l Yes l No
If No, submit completed worksheet for roof structure WKS1.
3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________
Mounting System Information:
1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap
beneath the module frames? l Yes l No
If No, provide details of structural attachment certified by a design professional.
2. For manufactured mounting systems, fill out information on the mounting system below:
a. Mounting System Manufacturer ___________Product Name and Model#________________________________
b. Total Weight of PV Modules and Rails ___________lbs
c. Total Number of Attachment Points____________
d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1)
e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for
maximum spacing allowed based on maximum design wind speed)
f. Total Surface Area of PV Modules (square feet)_________________ ft2
g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2
If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1.
Step 2: Electrical Review of PV System (Calculations for Electrical Diagram)
In order for a PV system to be considered for an expedited permit process, the following must apply:
1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems.
2. The PV array is composed of 4 series strings or less per inverter.
3. The total inverter capacity has a continuous ac power output 13,440 Watts or less
4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)).
5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV
system. Interactive PDF diagrams are available at www.solarabcs.org/permitting.
Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant
understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively
communicate, provide an alternative diagram with appropriate detail.
415 S Huron Dr -
201824154/10/2024
E
x
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
3
Standard String System Site Plan
Gate
Gate
S
H
u
r
o
n
D
r
18'' fire setback
36
'
'
f
i
r
e
s
e
t
b
a
c
k
MSP
SolarEdge Energy Bank Battery
INV
ACD
J/B
Solar Array
10 Canadian 400W Modules
10 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
415 S Huron Dr -
201824154/10/2024
E
x
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
4
Standard String System Electrical Diagram
415 S Huron Dr -
201824154/10/2024
E
x
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
5
Notes for Standard String System Electrical Diagram
Contractor Name,
Address and Phone:
_________________
_________________
_________________
_________________
Notes for One-Line Standard Electrical
Diagram for Single-Phase PV Systems
Site Name: __________________________
Site Address: ________________________
System AC Size: ______________________
SIZE FSCM NO DWG NO REV
SCALE NTS Date:SHEET
Drawn By:
Checked By:
MAX POWER-POINT CURRENT (IMP)
MAX POWER-POINT VOLTAGE (VMP)
OPEN-CIRCUIT VOLTAGE (VOC)
SHORT-CIRCUIT CURRENT (ISC)
MAX SERIES FUSE (OCPD)
MAXIMUM POWER (PMAX)
MAX VOLTAGE (TYP 600VDC)
VOC TEMP COEFF (mV/oC or %/oC )
IF COEFF SUPPLIED, CIRCLE UNITS
A
V
V
A
A
W
V
MODULE MAKE
MODULE MODEL
PV MODULE RATINGS @ STC (Guide Section 5)
MAX DC VOLT RATING
MAX POWER @ 40oC
NOMINAL AC VOLTAGE
MAX AC CURRENT
MAX OCPD RATING
V
W
V
A
A
INVERTER MAKE
INVERTER MODEL
INVERTER RATINGS (Guide Section 4)
1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THEREQUIREMENT? YES NO N/A
2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THEREQUIREMENT? YES NO N/A
3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAXCURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT
4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTEROCPD AMPERE RATING. (See Guide Section 9)
5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTALSUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)?YES NO
NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):
1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEANEXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC
2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHESTMONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC
2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT ATLEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF47oC OR LESS (ALL OF UNITED STATES),
a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLERFUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLERFUSE.
NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D):
OCPD = OVERCURRENT PROTECTION DEVICE
NATIONAL ELECTRICAL CODE® REFERENCES
SHOWN AS (NEC XXX.XX)
NOTES FOR ALL DRAWINGS:
SIGNS–SEE GUIDE SECTION 7
SIGN FOR DC DISCONNECT
SIGN FOR INVERTER OCPD AND
AC DISCONNECT (IF USED)
RATED MPP CURRENT
RATED MPP VOLTAGE
MAX SYSTEM VOLTAGE
MAX CIRCUIT CURRENT
A
V
V
A
PHOTOVOLTAIC POWER SOURCE
WARNING: ELECTRICAL SHOCK
HAZARD–LINE AND LOAD MAY BE
ENERGIZED IN OPEN POSITION
AC OUTPUT CURRENT
NOMINAL AC VOLTAGE
A
V
SOLAR PV SYSTEM
AC POINT OF CONNECTION
THIS PANEL FED BY MULTIPLE
SOURCES (UTILITY AND SOLAR)
415 S Huron Dr -
201824154/10/2024
•• ••• ••
CLEAN ENERGY
SOLUTIONS
To whom it may concern,
Clean Energy Solutions
417 W. Allen Ave Suite #105
San Dimas CA, 91773
800)994-1134
This letter authorizes B ernard Albosta to pull permits/ business license on behalf of Clean Energy Solutions.
If you have any question, please call us at 800) 994-1134
Sincerely,
David Gomez
CEO
A notary public or other officer comple�ng this
cerlificate verifies only the Identity of the
individual who signed lhe document 10 which lhis
certificate is attached, and nol the lruthlulness
accuracy, or validily of lhat document.
State of California County of / f)S �lc.J
Subscribe�nd sworn to (or affirmed)beore me
on thisl_day of ?:(� ,20 1-!J
by � Q-y\<k (-,ol\Jv+;.
proved to me on the basis of satisfactory evidence
to be the person( who app ared before me.
Signature (Nolary Seat)
'
@
ANDRE ROBINSONI , r. COMM # 2433203 �
:;; NOTARY PUBLIC· CAUFORNIA !'? I LOS ANGELES COUNTY Ilily Com! Ell)ltS JANUARY ll. 2027
q • 0
415 S Huron Dr -
201824154/10/2024
415 S Huron Dr -201824154/10/2024
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE
COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY
2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED
3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED
4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER.
5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING
COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED.
6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY
AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL
INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY.
7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE
COORDINATED WITH OTHER TRADES.
8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS
RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT.
9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE
WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE.
10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE
SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS.
OWNER
SCOPE
PROJECT
ADDRESS
PROJECT DATA GENERAL NOTES VICINITY MAP
SHEET INDEX
PHOTOVOLTAIC NOTES
SATELLITE VIEW
BUILDING
INFORMATION:
ELECTRICAL
INFORMATION
MAIN SERVICE PANEL
BUSBAR RATING
MAIN SERVICE
BREAKER RATING
1ɸ, 3W, 120/240V
RACKING
INFORMATION
Main Service Panel
Solar Module
Micro Inverter /
Optimizer
EMT / FMT / PVC
/ RMC type conduit/
Romex NM Cable/
FNMT (Fluid non-metalic tube)
36'' SetbackInverter
Utility Meter
Production Meter
PV Load Center
IQ Combiner Box
Junction Box
Sunpower PV Supervisor
18'' Setback
EV Outlet
CONSTRUCTION TYPE: V-B
ROOF
TYPE
AHJ
APN
LOT AREA
LIVING AREA
MSP
UM
PM
INV
PV
PVS6
IQ
J/B
EV
AREA ANZURES
10
1 SOLAR EDGE ENERGY HUB SE6000H-USSNBBL14 (240V)
1 SOLAR EDGE ENERGY BANK BATTERY 10kWh
415 S HURON DR,
SANTA ANA, CA 92704
AC DisconnectACD
SSP Service Sub Panel
COMPOSITION SHINGLE
1,448 SQFT
10982113
CITY OF SANTA ANA
ROOF MOUNT INSTALLATION OF
DC PHOTOVOLTAIC SYSTEM
3.95 KW DC
3.95 KW
3.68 KW AC
NEW UPGRADED
ALL OTHER ORDINANCE ADOPTED BY THE
LOCAL GOVERNING AGENCIES
THE INSTALLATION OF SOLAR ARRAYS AND
PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY
WITH THE FOLLOWING CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
2022 CALIFORNIA HISTORICAL CODE
2022 CALIFORNIA EXISTING BUILDING CODE
2022 CALIFORNIA REFERENCED STANDARDS CODE
2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE
1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703.
2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS
3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED.
4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER
OUTAGE.
5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING
ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS.
6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE.
7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE
ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED.
8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION
9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED
10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT.
11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING
MEANS AS PER 230.82(6)
12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING
AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122
13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122.
14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS
6,534 SQFT
Battery Backup BB
Auto TransformerAT
Solar Edge Meter EnclosureSEM
Distribution PanelDP
Rapid Shutdown Controller RSC
Rapid Shutdown Box RSB
Itron MeterIM
UNIT INDEX
CODE REFERENCES
IRONRIDGE RACKING
TRUSSES 2"X4" @ 24" O.C
OCCUPANCY: R
ONE STORY BUILDING
200A
200A
CANADIAN SOLAR 395W
CS6R-395MS-HL
(don't delete this note)
0 TITLE SHEET
SINGLE LINE DIAGRAM
CODE REQUIRED SIGNAGE
E 1.1
PV 2.0
ATTACHMENT LAYOUTS 1.0
PV 2.1
PV 3.0
INVERTER DATA SHEET
MODULE DATA SHEET
RACKING SPECIFICATIONS
ATTACHMENT SPECIFICATIONS
ROOF PLAN
MODULE MAP
WIRE SIZE CALCULATIONS
INVERTER MAP
GROUNDING SPECIFICATIONS
OPTIMIZER DATA SHEET
PV 0.0
E 1.0
SITE PLANPV 1.0
PV 3.1
PV 4.0
PV 4.1
PV 5.0
PV 5.1
PV 6.0
PV 6.1 BATTERY DATA SHEET
0
TITLE SHEET
The scope of the plans is for the installation of the solar
photovoltaic system only and the approval is subject to
compliance with all applicable city and state codes and
regulations regarding construction. The approval of the plans
does not constitute any certification of the accuracy,
completeness, or building permit status of the existing
buildings and structures as shown.
REVISION TO:
Bldg# 101118683
Elec# 20182415
Bldg# 101119092
Elec# 20182662
APPROVALS:
ELEC - MSmith
415 S Huron Dr -
101119092&20182662
REV5/21/2024
ROOF PLAN
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
N
0°
S
180°
E
90°
W
270°
SCALE
0 51 10ft
PHOTOVOLTAIC SYSTEM
1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V)
Solar Edge S440 Power Optimizers10
FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER
THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT3.95 KW DC
10 Canadian Solar 395W Modules (CS6R-395MS-HL)
Gate
Gate
S
H
u
r
o
n
D
r
18'' fire setback
36
'
'
f
i
r
e
s
e
t
b
a
c
k
MSP
SolarEdge Energy Bank Battery
INV
ACDJ/B
Solar Array 1
8 Canadian 395W Modules
8 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
ROOF AREA CALCULATIONS
FIRE SPRINKLERS - NO
TOTAL ROOF AREA (SQ.FT.) - 2865
SOLAR AREA (SQ.FT.) - 210
% OF COVERED AREA - 7.3%
PV 0.0
36'' fire setback
36'' fire setback
18
'
'
f
i
r
e
s
e
t
b
a
c
k
Solar Array 2
2 Canadian 395W Modules
2 S440 Optimizers
Tilt: 22 Deg
Azimuth: 95 Deg
415 S Huron Dr -
101119092&20182662
REV5/21/2024
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
SITE PLAN
N
0°
S
180°
E
90°
W
270°
PROPERTY LINE
Gate
Gate
S
H
u
r
o
n
D
r
Driveway
Pu
b
l
i
c
S
i
d
e
w
a
l
k
Pu
b
l
i
c
S
i
d
e
w
a
l
k
S
F
a
i
r
v
i
e
w
S
t
100'
60'
100'
21'
8'
33'
65'
MSP
INV
ACD
SCALE
0 51 10ft
SolarEdge Energy Bank Battery
PV 1.0
40'
415 S Huron Dr -
101119092&20182662
REV5/21/2024
ATTACHMENT
LAYOUT
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
STRUCTURAL STAMPROOF
PITCH
ROOFING
TYPE
ATTACHMENT
TYPE
FRAMING
TYPE
FRAMING
SIZE
PENETRATION
PATTERN
22°
RACKING
TYPE
MAX
PENETRATION
SPACING
ROOFING
LAYERS
WIND SPEED 95 MPH
SNOW LOAD 0 PSF
EXPOSURE C
LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE
SEALED WITH CHEM LINK SEALANT OR EQUIVALENT.
MODULE WEIGHT (LBS)
# OF MODULES
TOTAL MODULE WEIGHT (LBS)
RACK WEIGHT (LBS)
TOTAL SYSTEM WEIGHT (LBS)
# OF STANDOFFS
LOADING PER STANDOFF (LBS)
TOTAL MODULE AREA (SQ.FT.)
LOADING (PSF)
WEIGHT LOAD CALCULATION INDEX
ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER
SURFACE IS FACED WITH FELT PAPER
TOTAL ROOF AREA (Sq. FT)
% OF COVERED AREA
PV MODULE MODEL #
OPTIMIZERS WEIGHT (LBS)
10
Roof 1 Layer Comp Shingle Ironridge XR10 Truss Stacked 72"2"X4" @ 24" O.C
3
1
2
4
ITEM NO.
1
DESCRIPTION
2
3
4
BOLT LAG 5/16 X 4.75"
ASSY, FLASHING
ASSY, CAPFOOT
WASHER, EPDM BACKED
Qty in Kit
4
4
4
4
5/16" X 4.75"
Flash Foot 2
MIN 2.5" EMBEDMENT
RACKING RAIL
ATTACHMENT
ROOF FRAMING
20
210
2865
494
99
15
608
30.4
2.89
7.3
2''X6'' Blocking
SOLAR MODULE
ROOF
ASCE 7-16
Max 3.5''
49.4
CS6R-395MS-HL
S 1.0
72"24"
415 S Huron Dr -
101119092&20182662
REV5/21/2024
SINGLE LINE
DIAGRAM
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
ITEM DESCRIPTION QTY#
PV MODULE
MAIN SERVICE PANEL
MAIN SERVICE PANEL
& UTILITY METER
BUSBAR RATING
BREAKER RATING
1
ITEM DESCRIPTION QTY#
PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3
1
1
1
5
3
1
4
6
MAIN
SERVICE
PANEL
120/240V
1P,3W
2
EXISTING
GROUNDING SYSTEM
UTILITY
M
2
3
5700W
INVERTER
PEAK PWR TRACKING VOLTAGE
INVERTER EFFICIENCY
ENCLOSURE :
MAXIMUM INPUT CURRENT
MAXIMUM OUTPUT CURRENT
MAXIMUM INPUT POWER
MAXIMUM OUTPUT POWER
4 1
380 V
99.0 %
NEMA 4
16.5 A
25.0 A
12,000 W
6,000 W
SOLAREDGE ENERGY HUB SE6000H-USSNBBL14 (240V)
SOLAREDGE POWER OPTIMIZER
RATED DC INPUT POWER
MAXIMUM INPUT VOLTAGE
MPPT RANGE
MAXIMUM SHORT CIRCUIT CURRENT (Isc)
MAXIMUM OUTPUT CURRENT
OPTIMIZER WEIGHT
MAXIMUM POWER PER STRING
5
S440
440W
60 Vdc
8 to 60 Vdc
14.5 Adc
15 Adc
1.5 Lbs
10POWER OPTIMIZER
60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE,
BLADE TYPE, NEMA 3R, 120/240V 16
NEW UPGRADED
NEW
2
1
33
200A
200A
200A
FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3
INSTALL 2P
40A CB(PV) AT
OPPOSITE END
OF BUS FROM
MAIN FEEDER CB
10
Canadian Solar 395W
CS6R-395MS-HL
Voc = 36.6V
Vmp = 30.6V
Isc = 13.77A
Imp = 12.91A
(N)200A
7
(1)#10 AWG (10-12 AWG), 600V insulated
(1)#24 AWG (16-24 AWG), 600V insulated or CAT6
1" EMT TYPE Conduit
7 BATTERY BACKUP BATTERY BACKUP SYSTEMS
SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 1
String: (10) Modules, (10) Optimizers
E 1.0
415 S Huron Dr -
101119092&20182662
REV5/21/2024
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
FROM PV MODULES TO JBOX
FROM JBOX TO INVERTER
(2)
WIRE SIZE
CALCULATIONS
1
(1) #6 AWG BARE CU EGC,
2
#8 AWG CU EGC,
(3)
3
(1) #8 AWG CU EGC,
MAXIMUM INVERTER OUTPUT CURRENT (A)
TEMPERATURE FACTOR
TEMPERATURE ADJUSTMENT (A)
OUTPUT CALCULATIONS
PV SYSTEM MAX DC OUTPUT
PV SYSTEM MAX AC OUTPUT
MAXIMUM POWER (W)
PEAK PWR TRACKING VOLTAGE (V)
CONSIDER CONTINUOUS COEFFICIENT
SHORT CIRCUIT CURRENT (A)
ADJUSTED CONDUCTOR AMPACITY (A)
1.25
1.25
1.25
0.91
(2)
(1)
Pmax (PTC Rating)
25.0
380
99.0 %
25.0 * 1.25 / 0.91 34.4
#8 AWG THWN-2
SOLAR EDGE SE6000H-USSNBBL14 (240V)
25.0 * 1.25 31.3
1
1 1/2''
(TEMP - 39 + 22 = 61C)0.58
RACEWAY HEIGHT FROM ROOF
ADJST. FACTOR (1 thru 3 WIRES)1.0
FREE IN THE AIR
3/4'' FMT TYPE CONDUIT
1'' EMT TYPE CONDUIT
MAIN SERVICE PANEL RATING
BUSBAR RATING
MAIN BREAKER
PV BACKFEED BREAKER SIZE
120% RULE:
MAX ALLOWED FEED
40A
*/*1.25 *1.2510395380 16.2
//16.2 0.58 1.0 27.9
#10 AWG THWN-2
WIRE CHART WIRE CHART
*10 395 3.95 KW
**10 371.9 0.99 3.68 KW
CONSIDER CONTINUOUS COEFFICIENT
CONSIDER CONTINUOUS COEFFICIENT
200A
200A
240A
200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX
FROM INVERTER TO MAIN SERVICE PANEL
CONSIDER CONTINUOUS (A)
MAX NUMBER OF MODULES IN STRING 10
#10 AWG PV-WIRE
10
CS6R-395MS-HL 395 W
371.9 W
395
E 1.1
415 S Huron Dr -
101119092&20182662
REV5/21/2024
MODULE
MAP
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
[FOR INSTALLER USE ONLY]
PHOTOVOLTAIC SYSTEM
1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V)
Solar Edge S440 Power Optimizers10
3.95 KW DC
10 Canadian Solar 395W Modules (CS6R-395MS-HL)
Solar Array 1
8 Canadian 395W Modules
8 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
PV 2.1
Solar Array 2
2 Canadian 395W Modules
2 S440 Optimizers
Tilt: 22 Deg
Azimuth: 95 Deg
415 S Huron Dr -
101119092&20182662
REV5/21/2024
CODE REQUIRED
SIGNAGE
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
JB
B
O
X
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
CEC 110.27(C)
DC
D
i
s
c
o
n
n
e
c
t
CEC 690.13(B)
In
v
e
r
t
e
r
/
P
V
L
o
a
d
WARNING
THE DISCONNECTION OF THE
GROUNDING CONDUCTOR(S)
MAY RESULT IN OVERVOLTAGE
ON THE EQUIPMENT
CEC 690.31(E)
CEC 690.54
AC
D
i
s
c
o
n
n
e
c
t
CEC 690.54
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
PM
M
E
T
E
R
Ma
i
n
/
S
u
b
P
a
n
e
l
CEC 690.54
CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59
CEC 690.15 (B) & CEC 690.33(D)(2)
CEC 690.13(B)
SINGLE 120-VOLT SUPPLY
DO NOT CONNECT
MULTIWIRE BRANCH CIRCUIT!
CEC 710.15(C)
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
CEC 110.27(C)
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
CEC 705.12 (B)(3)(2)
LABELING REQUIREMENTS FOR ARTICLE 690
CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether
in the open (off) or closed (on) position and be permanently marked “PV SYSTEM
DISCONNECT” or equivalent. Additional markings shall be permitted based upon
the specific system configuration.
CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall
simultaneously disconnect the PV system conductors that are not solidly grounded
from all conductors of other wiring systems. The PV system disconnecting means or
its remote operating device or the enclosure providing access to the disconnecting
means shall be capable of being locked in accordance with 110.25.
CEC 690.15(B) An isolating device shall not be required to have an interrupting
rating. Where an isolating device is not rated for interrupting the circuit current, it shall
be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An
isolating device shall not be required to simultaneously disconnect all current-carrying
conductors of a circuit.
CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all
termination, connection, and splice points by color coding, marking tape, tagging, or
other approved means.
CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring
methods and enclosures that contain PV system dc circuit conductors shall be marked with the
wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of
permanently affixed labels or other approved permanent marking.
CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring
system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between
labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft).
Labels required in this section shall be suitable for the environment where they are installed.
CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a
permanent, legible warning notice indicating that the disconnection of the grounded
conductor(s) may result in overvoltage on the equipment.
CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a
tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”.
CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors,
and inverters shall be considered as internal components of an ac module or ac module
system.
CEC 690.53 A permanent readily visible label indicating the highest
maximum dc voltage in a PV system, calculated in accordance with 690.7,
shall be provided by the installer.
CEC 690.54 All interactive system(s) points of interconnection with other
sources shall be marked at an accessible location at the disconnecting
means as a power source and with the rated ac output current and the
nominal operating ac voltage.
CEC 690.55 The PV system output circuit conductors shall be marked to
indicate polarity where connected to energy storage systems.
CEC 690.56(A) Plaques or directories shall be installed in accordance with
705.10.
CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on
or no more than 1 meter (3 ft) from the switch.
CEC 690.59 PV systems connected to other sources shall be installed in
accordance with Parts I and II of Article 705 and Article 712.
SOLAR ELECTRIC
PV PANELS
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH ON THE
"OFF" POSITION TO
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN ARRAY
CFC 1205.4.1(1) & CEC 690.56(C)
CEC 690.56(C)(2)
CEC 690.31(D)(2)
CEC 690.31(D)(2)CO
N
D
U
I
T
RATED AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT
DC DISCONNECT
PHOTOVOLTAIC
WARNING
RATED AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT
RATED AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT WARNING
CAUTION
PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED
WARNING
POWER SOURCE OUTPUT
CONNECTION. DO NOT
RELOCATE THIS
OVERCURRENT DEVICE.
WARNING
DO NOT DISCONNECT
UNDER LOAD
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING
PHOTOVOLTAIC POWER SOURCE
DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW
FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT
DOWN THE ARRAY AND THE CONDUCTORS LEAVING
THE ARRAY, A LABEL SHALL BE PROVIDED. THE
FIRST TWO LINES OF THE LABEL SHALL BE
UPPERCASE CHARACTERS WITH A MINIMUM
HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A
YELLOW BACKGROUND. THE REMAINING
CHARACTERS SHALL BE UPPERCASE WITH A
MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON
A WHITE BACKGROUND. [CFC 1205.4.1(1)]
240 Vac
240 Vac
240 Vac
CEC 690.13(B)
AC DISCONNECT
PHOTOVOLTAIC
25.0 A MAX
25.0 A MAX
25.0 A MAX
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
CEC 690.13(B)
CEC 705.10
CAUTION
MULTIPLE SOURCES OF POWER
CEC 705.10
CAUTION
MULTIPLE SOURCES OF POWER
CEC 690.53
OF PV SYSTEM
MAXIMUM DC VOLTAGE
CEC 690.53
MAXIMUM SYSTEM VOLTAGE
RATED SHORT CIRCUIT CURRENT
N/AMAX RATED AC OPERATING VOLTAGE
N/ARATED AC OPERATING VOLTAGE
MAX RATED AC OPERATING CURRENT
RATED AC OPERATING CURRENT
N/A
N/A
N/A
N/A
CAUTION
N
0°
S
180°
E
90°
W
270°
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN:
CEC 705.10 & CEC 690.56(B)
Permanent directory or plaque providing location of service disconnecting means and
photovoltaic system disconnecting means, if not located at the same location. (Plaques shall
be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a
contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the
required location using an approved method that is suitable to withstand the environment to which it
is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion
requirements of Underwriters Laboratories marking and labeling system 969(UL969).
Plaques will have red background & white lettering.
SERVICE POINT &
UTILITY METERING
PV SYSTEM DISCONNECT
FOR UTILITY OPERATION
SOLAR INVERTER
SOLAREDGE ENERGY
BANK BATTERY
SOLAR ARRAY
ON THE ROOF
S
H
u
r
o
n
D
r
PV 2.0
415 S Huron Dr -
101119092&20182662
REV5/21/2024
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
INVERTER
MAP
INVERTERPHOTOVOLTAIC SYSTEM
1 Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNBBL14 (240V)
Solar Edge S440 Power Optimizers10
3.95 KW DC
[FOR INSTALLER USE ONLY]
10 Canadian Solar 395W Modules (CS6R-395MS-HL)
PV 3.0
Solar Array 1
8 Canadian 395W Modules
8 S440 Optimizers
Tilt: 22 Deg
Azimuth: 185 Deg
Solar Array 2
2 Canadian 395W Modules
2 S440 Optimizers
Tilt: 22 Deg
Azimuth: 95 Deg
415 S Huron Dr -
101119092&20182662
REV5/21/2024
MODULE
DATA SHEET
PV SYSTEM
AS INDICATED
APRIL 22, 2024
AREA ANZURES
415 S HURON DR,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Inter Solar Cad
www.intersolarcad.com
PV 3.1
415 S Huron Dr -
101119092&20182662
REV5/21/2024
415 S. HURON DR.
SANTA ANA, CA 92704
ANZURES, AREA
Design Criteria
1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16
2 - Wind: 95 MPH, Exposure: C
3 - Wood Species: DF-L No. 1 (SG = 0.5 )
Notice: Use restrictions of these calculations.
The attached Calculations are valid only when bearing original signature hereon.
Contractor/Client to verify existing dimensions/conditions prior to construction
& solar racking is installed per manufacturer span requirements.
The use of these calculations is solely intended for the above mentioned project.
1-844-PV ELITE | info@yoursolarplans.com
3000 E. Birch Street Suite 201 | Brea CA 92821
4/26/2024
Structural Calculations for
SOLAR POWER SYSTEM CONNECTION CHECK AT:
Job:
415 S Huron Dr -
101119092&20182662
REV5/21/2024
!"#$%&