HomeMy WebLinkAbout2307 N Towner St - Plan0 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV DAVID VANDERVOORT 18 18 ENPHASE IQ8PLUS-72-2-US 2307 N TOWNER ST, SANTA ANA, CA 92706 AC DisconnectACD SSP Service Sub Panel M CONCRETE TILE 2,741 SQFT 00121406 CITY OF SANTA ANA ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 7.20 KW DC 7.20 KW 6.49 KW AC NEW UPGRADED 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER SEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 10,496 SQFT Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES ECOFASTEN CLICKFIT 2"X4" @ 24" O.CFRAMING OCCUPANCY: R ONE STORY BUILDING 175A 225A HANWHA 400W Q.PEAK DUO BLK ML-G10+ 400 (don't delete this note) 0 COVER PAGE SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET ROOF PLAN WIRE SIZE CALCULATIONS D2 D3 D4 D5 GROUNDING SPECS IQ COMBINER BOX DATA SHEET 1 2 1.1 SITE PLAN D6 SURVEY PHOTO D7 1 TESLA POWERWALL 2 AC BATTERY WITH TESLA BACKUP GATEWAY D8 BATTERY DATA SHEET ATTACHMENT DATA SHEET ATTACHMENT DATA SHEETD5.1 IRONRIDGE ROOF MOUNT GROUNDING SPECS D4.1 RACKING DATA SHEET D6.1 D9 3.1 PANEL SCHEDULES 3.2 GENERATION PANEL LOAD CALCULATIONS NEW PV SYSTEM SIZE EXISTING PV SYSTEM SIZE TOTAL PV SYSTEM SIZE 7.20 KW AC 10.26 KW AC 17.46 KW AC Signed 08/09/2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101114193 Elec# 20178963 MSmith Issued 10/17/23 2307 N Towner St - 2017896310/18/2023 1.1 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR SITE PLAN N 0° S 180° E 90° W 270° SCALE 20ft1050 POOL 130' 80' 48' 5' 23' 64' Driveway N T o w n e r S t Pu b l i c S i d e w a l k Gate Gate MSP PROPERTY LINE ACD IQ TESLA BACKUP GATEWAY GENERATION PANEL TESLA POWERWALL AC II BATTERY NOTE: Meter Spot is approved for the same location. Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 1 ROOF PLAN PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 4,610 SOLAR AREA (SQ.FT.) - (E)760+(N)378=1,138 % OF COVERED AREA - 24.7% PHOTOVOLTAIC SYSTEM 18 Enphase Energy Microinverters (IQ8PLUS-72-2-US) FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT7.20 KW DC 18 Hanwha 400W Modules (Q.PEAK DUO BLK ML-G10+ 400) N 0° S 180° E 90° W 270° SCALE 0 51 10ft 18'' fire setback 18'' f i r e s e t b a c k 18'' f i r e s e t b a c k 18'' f i r e s e t b a c k MSP J/B N T o w n e r S t Existing Solar System Existing Solar System Solar Array 3 11 Hanwha Q.Cell 400W 11 IQ8+ Microinverters Pitch: 20 Deg Azimuth: 180 Deg Solar Array 2 3 Hanwha Q.Cell 400W 3 IQ8+ Microinverters Pitch: 20 Deg Azimuth: 180 Deg Gate Gate TESLA BACKUP GATEWAY GENERATION PANEL TESLA POWERWALL AC II BATTERY ACD IQ a a a b b b bb b b bb bb 18'' f i r e s e t b a c k 18 ' ' f i r e s e t b a c k a a a a Solar Array 1 4 Hanwha Q.Cell 400W 4 IQ8+ Microinverters Pitch: 20 Deg Azimuth: 270 Deg Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 2 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 M MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY 2 3 INVERTER PEAK PWR TRACKING VOLTAGE CEC EFFICIENCY PROTECTION RATING: MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM CONTINUOUS OUTPUT POWER 4 18 Enphase Energy Microinverters (IQ8PLUS-72-2-US) 29-45 V 97.0 % NEMA 6 15.0 A 1.21 A 235-440 W 290 W IQ COMBINER INSTALL 15A PV 2-POLE C/B INSTALL 20A PV 2-POLE C/B 0 1 8 1 15A PV 2-POLE C/B (2)#14 AWG THWN-2 (L1+L2) (1)#14 AWG-NEUTRAL IQ GATEWAY INFORMATION ENPHASE IQ COMBINER BOX WITH ENPHASE IQ GATEWAY 120/240V, NEMA 3R MODEL# X-IQ-AM1-240-(4/4C) 30AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 NEW UPGRADED PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AND COMPLIANT WITH NEC 690.12 1175A 225A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 18 HANWHA 400W Q.PEAK DUO BLK ML-G10+ 400 Voc = 45.30V Vmp =37.13V Isc = 11.14A Imp = 10.77A 1 4 3 1 8 15A 2 3 20A 10 CT R L 100A TESLA BACKUP GATEWAY NEMA3R, 100A MAX (3) #3 AWG TWHN-2 (1) #8 AWG EGC/GEC 1 1/4" EMT TYPE CONDUIT TESLA POWERWALL AC II BATTERY (3) #10 AWG TWHN-2 (1)#8 AWG EGC/GEC 7 20A Branch a : (7) Modules, (7) Microinverters GENERATION PANEL 120/240V 1P/3W10 125A 1GENERATION PANEL 13.5 kWh POWERWALL 2 AC 120/240V 1P/3W7 1TESLA BATTERY (N) 175A 30A EXISTING ABB PVI-3.8-OUTD-US INVERTER EXISTING (19) TRINASOLAR TSM-270PD05. 18 270W MODULES EXISTING ABB PVI-3.8-OUTD-US INVERTER EXISTING (19) TRINASOLAR TSM-270PD05. 18 270W MODULES 6 3 100A INSTALL 2P 30A CB(PV) EXISTING (2)#10 AWG THWN-2 (1)#8 AWG BARE CU EGC 3/4'' EMT TYPE CONDUIT EXISTING (2)#10 AWG PV-WIRE (1) #6 AWG BARE CU EGC EXISTING (2)#10 AWG THWN-2 (1)#8 AWG BARE CU EGC 3/4'' EMT TYPE CONDUIT Branch b : (11) Modules, (11) Microinverters 20A 225A NEW Existing PV system is NOT RS compliant. 20A Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 97% 0.97 1.21 1.21 18 IQ8PLUS-72-2-US (CEC) FROM JBOX TO IQ COMBINER BOX FROM IQ COMBINER BOX TO GENERATION PANEL 1 1/2'' TEMP. DERATE FACTOR (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR 3 WIRE SIZE CALCULATIONSFROM PV MODULES TO JBOX #12 AWG Q-CABLE, PV WIRE(4)1 (1) #6 AWG BARE CU EGC 2 #8 AWG CU EGC, (3) 3 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT WALL TEMPERATURE FACTOR OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT 1.25 0.91 (4) (1) 18 Pmax (PTC Rating) 3/4'' EMT TYPE CONDUIT 3/4'' EMT TYPE CONDUIT #10 AWG THWN-2 WIRE CHART WIRE CHART a b 2 BRANCH CIRCUITS INVERTER OUTPUT MAX CURRENT COEFFICIENT 1.25 BRANCH CIRCUIT CURRENT a: 7 BREAKER SIZE PER BRANCH CRCT 20A 0.8ADJST. FACTOR (4 thru 6 WIRES) * *1.257 1.21 10.6A ADJUSTED CONDUCTOR AMPACITY / /16.6 0.58 0.8 35.8A NUMBER OF MICROINVERTERS 7.20KW 6.49KW MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 30A 175A 225A 270A 175A''MB'' + (N)30A "SOLAR"+(E)30A "SOLAR"= 235A ≤ 270A MAX WIRE CHART QTY CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS (A)1.25* *18 1.21 27.2 *1.25 / 0.91*18 1.21 29.9 #10 AWG THWN-2 TEMPERATURE ADJUSTMENT (A) 18 18 18 400W * 400 371.5W * 371.5 * Q.PEAK DUO BLK ML-G10+ 400 117 BRANCH CIRCUIT CURRENT b: 11 BREAKER SIZE PER BRANCH CRCT 20A* *1.2511 1.21 16.6A a) The feeder and OCPD supplying the backup loads panel must have an ampacity greater than the backup loads calculation. b) Utility power must be able to supply 100% of the backup loads. c)Any one load cannot exceed the sustained power output rating of the non-utility backup source(s). CEC 702.4(B)(1) The ampacity of relocated load conductors must be adjusted for ambient temperature and number of current-carrying conductors in a conduit. CEC 310.15(A, B, C(1)) a) Conductors routed on the exterior will need to be adjusted for a maximum ambient temperature of 96°F-104°F. CEC 310.15(B)(1) b) More than 9 current-carrying conductors in a 24in. or longer conduit will generally require an increase in wire gauge due to reduced ampacity. CEC 310.15(C)(1) c) The adjusted conductor ampacity must be equal to or greater than the circuit ampacity (OCPD). CEC 240.4 Arc-fault circuit-interrupter (AFCI) protection must be provided for relocated circuits when the extending raceway(s) is greater than 6 feet. This applies to all dwelling unit 120-volt 15A and 20A branch circuits except those supplying outlets and devices exclusively in bathrooms, garages, attics, crawl spaces, and outdoors. CEC 210.12(A) A Surge-Protective Device is required for this new service panel. The 2022 California Electrical Code (CEC) requires all dwelling units to have an SPD installed for any new or replaced service. These shall be of SPD Type 1 or Type 2. CEC Section 230.67, Article 242 Multi-wire circuits must be preserved. When multi-wire circuits are relocated, they must be grouped, tagged, and otherwise identified as to the two ungrounded and single grounded (neutral) conductors. 2-pole circuit breakers are required for each relocated multi-wire circuit. CEC 210.4(B,D) Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 11.14 A CODE REQUIRED SIGNAGE 4 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR 60 Hz 290 W N/A CAUTION NEC 705.10(B) & NEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. N 0° S 180° E 90° W 270° CONTACT EXO ENERGY SOLAR (888) 463-9667 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) DC D i s c o n n e c t ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 NEC 690.13(B) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(I) NEC 690.54 AC D i s c o n n e c t NEC 690.54 NEC 690.52 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) PM M E T E R NEC 705.12(D)(3) & NEC 690.59 Ma i n / S u b P a n e l NEC 690.54 NEC 690.13 (F), NEC 705.12(B)(3-4) & NEC 690.59 NEC 705.12(D)(3) & NEC 690.59 NEC 690.15 (C) & NEC 690.33(E)(2) NEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT NEC 710.15(C) & 692.9 (C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) NEC 705.12 (B)(2)(c) LABELING REQUIREMENTS FOR ARTICLE 690 NEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked “PV SYSTEM DISCONNECT” or equivalent. Additional markings shall be permitted based upon the specific system configuration. For PV system disconnecting means where the line and load terminals may be energized in the open position, the device shall be marked with the following words or equivalent. NEC 690.13(F) Type of Disconnect. A dc PV system disconnecting means shall be marked for use in PV systems or be suitable for backfeed operation. NEC 690.15(C) An isolating device shall be rated to open the maximum circuit current under load or be marked “Do Not Disconnect Under Load” or “Not for Current Interrupting.” NEC 690.31(B)(1) PV system circuit conductors shall be identified at all accessible points of termination, connection and splices. The means of identification shall be permitted by separate color coding, marking tape, tagging or other approved means. NEC 690.31(G)(1) Where circuits are embedded in build up, laminate or membrane roofing materials not covered by PV modules and associated equipment, the location of the circuits shall be clearly marked. NEC 690.31(G)(4) PV dc system circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. NEC 690.31(I) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. NEC 690.33(E)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting.” NEC 690.52 Alternating-current modules shall be marked with identification of terminals or leads and with identification of the following ratings. NEC 690.53A permanent label for the dc PV power source indicating items (1) through (3) shall be provided by the installer at dc PV system disconnecting means and at each dc equipment disconnecting means required by 690.15. Where a disconnecting means has more than one dc PV power source, the values in 690.53 (1) through (3) shall be specified for each source. NEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked as an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. NEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. NEC 690.56(B)Plaques or directories shall be installed in accordance with 705.10. NEC 690.56(C)(3) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch that includes the following wording. NEC 690.56(C)(1)(a-b) The type of PV system shall be labeled as described in a) or b): NEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY IFC 605.11.3.1(1) & 690.56(C)(1)(a) NEC 690.56(C)(3) NEC 690.31(G)(3)(4) NEC 690.31(G)(1)CO N D U I T RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) DC DISCONNECT PHOTOVOLTAIC WARNING WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUT DOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW WARNING FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGH TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 50.74 V 240 Vac 240 Vac 240 Vac 240 Vac NEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 30 A 21.78 A 21.78 A 21.78 A 21.78 A MAIN PANEL TESLA BATTERY GENERATION PANEL N T o w n e r S t PV DISCONNECT NOT RS COMPLIANT Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 ATTACHMENT LAYOUT 5 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 20° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 110 MPH EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # MICROINVERTER WEIGHT (LBS) 18 Roof 1 1 Layer M Concrete Tile EcoFasten Truss Stacked 48"2"X4" @ 24" O.C 2''X6'' Blocking SOLAR MODULE ROOF 1,2 ASCE 7-16 Max 3.5'' 48.5 Q.PEAK DUO BLK ML-G10+ 400 47 378 4610 873 175 43 1090 23.2 2.88 8.2 20°Roof 2 1 Layer Comp Shingle Ironridge XR10 Truss Stacked 48"2"X4" @ 24" O.C PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085D FLASHLOC COMP KIT DARK, 20 PACK SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT SS SERRATED FLANGE NUT FLASHLOC BASE MILL OR DARK 33 21 4" 31 2" 67 8" Unirac Flashloc Kit MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING 5/16" X 4.0" Ecofasten Universal Tile Hook ATTACHMENT DETAILS ROOF SHEETING WATERPROOF MEMBRAIN ROOF TILE ECOFASTEN RAIL 5/16"x4.0" LAG BOLT WITH 2 1/2"MIN THREAS PENETRATION ECOFASTEN'S CLICKFIT UNIVERSAL TILE HOOK TILE HOOK FLASHING TILE HOOK ADDENDUMSOLAR MODULE 48''24'' Roof 2 Roof 2 Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 D1 MODULE DATA SHEET PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 INVERTER DATA SHEET PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D2 Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR IQ COMBINER BOX DATA SHEET D3 Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D4.1 RACKING DATA SHEET Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D4 RACKING DATA SHEET Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D5.1 ATTACHMENT DATA SHEET Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D5 ATTACHMENT DATA SHEET Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D6.1 GROUNDING SPECS Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D6 GROUNDING SPECS Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D7 BATTERY DATA SHEET Signed 08/09/2023 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D8 SURVEY PHOTO 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR D9 SURVEY PHOTO 2307 N Towner St - 2017896310/18/2023 3.1 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR PANEL SCHEDULES GENERATION PANEL SCHEDULE 1 2 3 4 15A 5 6 15A 7 8 20A 9 N/A / A/C 30A/30A 10 20A 11 A/C / N/A 30A/30A 12 20A 13 Old Solar/Batt 20A/30A 14 20A 15 Batt/Old Solar 30A/20A 16 20A 17 Old Solar/New Solar 20A/30A 18 19 New Solar/Old Solar 30A/20A 20 MAIN SERVICE PANEL SCHEDULE 1 A/C 40A 2 20A/20A 3 4 5 Tesla Gateway 100A 6 Range 50A 7 8 9 30A 10 50A 11 12 13 20A 14 20A 15 16 17 18 Meter 20A 19 20 2307 N Towner St - 2017896310/18/2023 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR 3.2 GENERATION PANEL LOAD CALCULATIONS 2307 N Towner St - 2017896310/18/2023 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com December 14, 2022 Revised May 16, 2023 EXO Energy 1247 Simpson Way Escondido, CA 92029 Re: Engineering Services Vandervoort Residence 2307 North Towner Street, Santa Ana CA 7.200 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A.Site Assessment Information 1.Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2.Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B.Description of Structure: Roof Framing: Assumed prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Concrete Tile & Composite Asphalt Shingles Roof Slope: 20 degrees Attic Access: Inaccessible Foundation: Permanent C.Loading Criteria Used •Dead Load o Existing Roofing and framing = 13 psf o New Solar Panels and Racking = 3 psf o TOTAL = 16 PSF •Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf •Live Load = 20 psf (reducible) – 0 psf at locations of solar panels •Ground Snow Load = 0 psf •Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 95 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2022 California Building Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. 2307 N Towner St - 2017896310/18/2023 Page 2 of 2 D.Solar Panel Anchorage 1.Concrete Tile i.The solar panels shall be mounted in accordance with the most recent EcoFasten installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. ii.The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National D esign Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. iii.Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on centers. 2.Composite Asphalt Shingles i.The solar panels shall be mounted in accordance with the most recent Unirac installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. ii.The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. iii.Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2022 California Building Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE California License No. 83664 2307 N Towner St - 2017896310/18/2023 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com Existing Vandervoort Residence Roof Dead Load 2307 North Towner Street 2.0 psf Composite Shingle Santa Ana, CA 1.6 psf 1/2" Plywood Sheathing 0.8 psf 2x4 Trusses @ 24 in. o.c. 1.0 psf Ceiling, Mechanical, Electrical 1.6 psf Miscellaneous 7.0 psf TOTAL Second Floor Dead Load 0 psf Floor Finishes 0 psf 1 1/8" Subfloor Sheathing 0 psf Joists @ 16' o.c. 0 psf Partitions 0 psf Ceiling, Mechanical, Electrical 0 psf Miscellaneous 0 psf TOTAL Roof Live Load Floor Live Load 20 psf 0 psf Roof Snow Load Ground SnowLoad=0 psf (to be divided by cosine of roof angle for horizontal projection ASCE 7 Sec. 7.4) pf = 0.7 Ce Ct I pg =0 psf Ce = 1, Ct = 1.1 Flat Roof Snow Load (ASCE 7-16 Eq. 7.3-1) Cs =0.91 ASCE 7-16 Figure 7.4-1 Additional Roof Dead Load - New Solar Panels 3 psf Roof Live Load at Solar Panels 0 psf Roof Snow Load at Solar Panels 0 psf Sloped Roof Snow Load (ASCE 7-16 Eq. 7.4-1) Total Total Existing Roof Load = (DLROOF + Max(LLROOF or S)) AreaROOF 124470 lbs Total New Roof Load = (DLROOF + DLADD + Max(LLROOF or S)) AreaROOF 117848 lbs Change in Demand = (Total New Roof Load - Existing Roof Load) / Existing Roof Load -5.32% 2021 IEBC Section 805.2 states: "Any existing gravity load-carrying structural element for which an alteration causes an increase in design gravity load of more than 5 percent shall be strengthened, supplemented, replaced or otherwise altered as needed to carry the increased gravity load required by this code for new structures." Gravity Loads Total New Gravity Loads are less than Existing Loads. OK Signed 5/16/2023 2307 N Towner St - 2017896310/18/2023 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com V =95 Basic Wind Speed Vandervoort Residence Exposure C ASCE 7-16, Section 26.7 2307 North Towner Street Kz =0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA Kzt =1 Topographic Factor, ASCE 7-16, Section 26.8.2 Kd =0.85 Directionality Factor, ASCE 7-16, Section 26.6 Ke =0.995 Ground Elevation Factor, ASCE 7-16, Section 26.9 qh =16.6 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) Roof Angle =20 deg Roof Type Gable sanchor =48 in Horizontal spacing of roof anchors Atrib =12.33 sf Panel Area tributary to each roof anchor GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 Roof Zone Zone 1 2e 2n 2r 3e 3r -2.00 -2.00 -2.98 -2.98 -2.98 -3.55 ga =0.79 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 gE =1.00 Edge Array Factor, ASCE 29.4.4 edges < 0.5*building height, and panel spacing < 4ft. pnet = qhGCpgEga =Design Wind Pressure, ASCE 7-16, Equation 29.4-7 Roof Zone 1 2e 2n 2r 3e 3r -26 psf -26 psf -39 psf -39 psf -39 psf -47 psf Min Pressure = -16 psf Use 26 psf Use 26 psf Use 39 psf Use 39 psf Use 39 psf Use 47 psf ULTIMATE x 0.6 =16 psf 16 psf 23 psf 23 psf 23 psf 28 psf ALLOWABLE Connection to Existing Roof Framing F.S. =1 Additional Factor of Safety applied to withdrawl force, if desired Atrib =12.3 ft2 DLpanel =3 psf Roof Zone 1 2e 2n 2r 3e 3r Wuplift =26 psf 26 psf 39 psf 39 psf 39 psf 47 psf Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor Roof Zone 1 2e 2n 2r 3e 3r -174.9 lbs -174.9 lbs -270.1 lbs -270.1 lbs -270.1 lbs -325.7 lbs Connection Capacity db =5/16 in Lag Screw diameter Dpen =2 1/2 in Lag Screw penetration into existing framing member No. of Screws 2 Screws per Connection Species of wood framing CD =1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 Ct =0.7 Temperature Factor, NDS Table 10.3.4 W =205 lb/in Withdrawl Capacity, NDS Equation 11.2-1 W' = CD x Ct x W =229 lb/in Adjusted withdrawl value Pallow = Dpen x W' =1147 lbs (Using (2) screws per connection) Roof Zone 1 2e 2n 2r 3e 3r DEMAND =175 lbs 175 lbs 270 lbs 270 lbs 270 lbs 326 lbs CAPACITY =1147 lbs 1147 lbs 1147 lbs 1147 lbs 1147 lbs 1147 lbs up to72in ok up to72in ok up to72in ok up to72in ok up to72in ok up to72in ok Spruce-Pine-Fir Wind Uplift Rooftop Solar Panels Parallel to Roof Surface ASCE 7-16, Section 29.4.4 This analysis calculates the capacity of the lag screws only. For capacity of the complete mounting system, please see manufacturer's recommendations. Signed 5/16/2023 2307 N Towner St - 2017896310/18/2023 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2307 N Towner St - 2017896310/18/2023 2307 N Towner St - 2017896310/18/2023 Certificate Of Completion Envelope Id: 1D151051274C4D8BA89565DE58EBBF7D Status: Completed Subject: Complete with DocuSign: Revision sheet -22.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 1 Initials: 0 Wesley Calland AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) pto@goexoenergy.com IP Address: 70.166.84.110 Record Tracking Status: Original 12/28/2022 10:17:00 AM Holder: Wesley Calland pto@goexoenergy.com Location: DocuSign Signer Events Signature Timestamp DAVID VANDERVOORT david.vandervoort@yahoo.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 76.170.1.138 Signed using mobile Sent: 12/28/2022 10:17:56 AM Viewed: 12/28/2022 10:27:06 AM Signed: 12/28/2022 10:27:22 AM Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Justin Romeo Justinr@goexoenergy.com Security Level: Email, Account Authentication (None) Sent: 12/28/2022 10:17:57 AM Electronic Record and Signature Disclosure: Not Offered via DocuSign Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 12/28/2022 10:17:57 AM Certified Delivered Security Checked 12/28/2022 10:27:06 AM Signing Complete Security Checked 12/28/2022 10:27:22 AM Completed Security Checked 12/28/2022 10:27:22 AM Payment Events Status Timestamps 2307 N Towner St - 2017896310/18/2023 3.1 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR PANEL SCHEDULES GENERATION PANEL SCHEDULE 1 2 3 4 15A 5 6 15A 7 8 20A 9 N/A / A/C 30A/30A 10 20A 11 A/C / N/A 30A/30A 12 20A 13 Old Solar/Batt 20A/30A 14 20A 15 Batt/Old Solar 30A/20A 16 20A 17 Old Solar/New Solar 20A/30A 18 19 New Solar/Old Solar 30A/20A 20 MAIN SERVICE PANEL SCHEDULE 1 A/C 40A 2 20A/20A 3 4 5 Tesla Gateway 100A 6 Range 50A 7 8 9 30A 10 50A 11 12 13 20A 14 20A 15 16 17 18 Meter 20A 19 20 Signed 08/09/2023 REVISION TO: 20178963 Revised 20181798 APPROVALS: ELEC - MSmith 2307 N Towner St - 201817982/9/2024 PV SYSTEM AS INDICATED AUGUST 09, 2023 DAVID VANDERVOORT 2307 N TOWNER ST, SANTA ANA, CA 92706 Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: CONTRACTOR 3.2 GENERATION PANEL LOAD CALCULATIONS Signed 08/09/2023 2307 N Towner St - 201817982/9/2024 CALIFORNIA LICENSE NO. C83664 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA PV-1 AERIAL MAP VICINITY MAP SCOPE OF WORK CONTRACTOR DATE: DRAWN BY: REVIEWED BY: CODE REFERENCE DESIGN CRITERIA 2307 NORTH TOWNER STREET, SANTA ANA, CALIFORNIA 92706 (33.767339,-117.879137) 18 MODULES - 7.200 KW DC 6.984 KW AC SYSTEM SIZE DAVID VANDERVOORT RESIDENCE - 2307 NORTH TOWNER STREET, SANTA ANA, CALIFORNIA 92706 NEW PV ROOFTOP AND BATTERY SYSTEM DESIGN ABD 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 2. ALL COMPONENTS SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND LISTED FOR THEIR SPECIFIC APPLICATION. 3. OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED OR BETTER. 4. ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING, AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER THE MANUFACTURER'S REQUIREMENTS. ALL PV MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 7. DC CONDUCTORS SHALL BE RUN IN EMT AND/OR MC (METAL CLAD CABLE) AND SHALL BE LABELED. ALL DC CONDUCTORS RUN INSIDE OF THE STRUCTURE SHALL BE INSTALLED A MINIMUM OF 18" BELOW THE ROOF DECK. 8. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH APPLICABLE NEC. 9. CONFIRM LINE SIDE VOLTAGE AT THE ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 10. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CODE. 11. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 12. ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED. 13. EQUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EQUIPMENT BASED ON AVAILABILITY. SUBSTITUTED EQUIPMENT SHALL COMPLY WITH DESIGN CRITERIA. 14. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 15. WHENEVER A DISCREPANCY IN THE QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ENGINEERS. GENERAL NOTES ATF SCOTT E. WYSSLING, P.E. INSTALL 7.200 KW DC ROOF MOUNTED PV SYSTEM UTILIZING (18) HANWHA Q.CELL BLK ML-G10+ 400 (18) ENPHASE IQ8PLUS-72-2-US (1) ENPHASE - X-IQ-AM1-240-4C (1) 30A PV AC DISCONNECT (1) 30A ESS AC DISCONNECT (1) 125 GENERATION PANEL (1) TESLA BACKUP GATEWAY 2 (1) TESLA POWERWALL AC II BATTERY ECOFASTEN CLICKFIT RAIL RACKING WITH (51) ECOFASTEN TILE HOOK FLASHING MOUNTS NEW 225 A BUSBAR WITH 175 A MAIN BREAKER INTERCONNECTION METHOD: LOAD SIDE BREAKER ROOF TYPE: CONCRETE W TILE NUMBER OF STORIES: 1 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 ASCE 7-16 WIND SPEED: 95 MPH EXPOSURE CATEGORY C GROUND SNOW LOAD: 0 PSF AHJ: SANTA ANA 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 7/26/2024 COVER SHEET SHEET INDEX PV-1 PV-3 PV-4 S-1 E-1 E-2 E-3 SITE PHOTOS PV LABELS EQUIPMENT INFORMATION ELECTRICAL DIAGRAM STRUCTURAL DETAILS MOUNTING PLAN SITE PLAN-2 COVER SHEET PV-5 MANUFACTURER'S SPECSSPECS 1-7 INSTALL CHECKLISTPV-6 E-4 PLACARD 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 DESIGN ENGINEER SOLAR COMPANY/CLIENT REVISIONS NO. 1 2 DATE swyssling@wysslingconsulting.com (201) 874-3483 COMMENTS PV-2 SITE PLAN-1 E-5 ELEVATION DETAILS 07/26/2024 ESS DISCONNECT LOCATION Signed 7/26/2024 Elec#: 20183254 Revision to: Elec# 20178963 & 20181798 Approvals: M Smith The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 2307 N Towner St 8/23/2024 EW S N VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 ÀPN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA UM MSPBI GENINVINVCOM AC ACB (E) CONCRETE DRIVEWAY NO R T H T O W N E R S T R E E T SWIMMING POOL (TYP.) FR O N T O F H O M E PROPERTY LINE B BB GATE GATE UTILITY METER MAIN SERVICE PANEL AC DISCONNECT DC DISCONNECT AC COMBINER PANEL INVERTER BACKUP INTERFACE BATTERY PRODUCTION METER SUBPANEL UNCTION BOX FIRE PATHWAY PROPERTY LINE ATTIC RUN CONDUIT EXTERNAL CONDUIT SATELLITE DISH SITE PLAN LEGEND MODULE SPEC AND ROOF INFO: SCALE: 1/16À À 1À-0À ROOF OBSTRUCTION (TYP.) CHIMNEY ROOF VENT (TYP.) COM PM B B UM MSP INV DC BI AC SUB PV MODULE TYPE - HANWHA .CELL BLK ML-G10À 400 (400W) SOLAR AREA - 380.44 S FT EXISTING SOLAR AREA - 635.04 S FT ROOF AREA - 4610 S FT ROOF COVERAGE -22.03 UTILITY: GAS METER GM PV-2 DATE:8/9/2024 SITE PLAN-1 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 I SYSTEM CONTROLLER I SITE PLAN NOTES: 1. VERIFY ALL OBSTRUCTIONS AND DIMENSIONS IN THE FIELD. 2. PROVIDE RAIL SPLICES AS REUIRED BY MANUFACTURERÀS GUIDELINES. 3. NO SIGNIFICANT SHADING WILL RESULT FROM EXISTING ROOF OBSTRUCTIONS. 4. PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ATTIC, PLUMBING, FURNACE OR WATER HEATER VENTS 5. AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESSIBLE. TO BE WITHIN 10À OF THE UTILITY METER 6. 3/4À OR GREATER CONDUIT RUN (7/8À ABOVE ROOF SURFACE) 7. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. LOAD CENTER LC 127À-11À 81À-11À 125À-4À 82À-5À 3À-9À 36À-11À 7À-1À 17À-11À 2307 N Towner St 8/23/2024 EW S N ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 ÀPN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 (E) INVERTER B (E) INVERTER NO R T H T O W N E R S T R E E T FR O N T O F H O M E B BB 18À FIRE PATHWAY (TYP.) ROOF ACCESS POINT ROOF OBSTRUCTION (TYP.) (E) UTILITY METER (N) BACKUP GATEWAY (N) BATTERY (N) MAIN SERVICE PANEL (N) GENERATION PANEL (N) AC COMBINER PANEL ROOF SECTION 1 TILT: 20À AZIMUTH: 270À ROOF SECTION 2 TILT: 20À AZIMUTH: 180À ROOF SECTION 3 TILT: 20À AZIMUTH: 180À (N) AC DISCONNECT (N) ESS DISCONNECT (E) PV SYSTEM CHIMNEY (TYP.) (N) PV MODULE EUIPPED W/ 1 MICRO-INVERTER PER MODULE AC UM MSPBI GENINVINVCOM AC UTILITY METER MAIN SERVICE PANEL AC DISCONNECT DC DISCONNECT AC COMBINER PANEL INVERTER BACKUP INTERFACE BATTERY PRODUCTION METER SUBPANEL UNCTION BOX FIRE PATHWAY PROPERTY LINE ATTIC RUN CONDUIT EXTERNAL CONDUIT SATELLITE DISH SITE PLAN LEGEND MODULE SPEC AND ROOF INFO: SCALE: 3/32À À 1À-0À ROOF OBSTRUCTION (TYP.) CHIMNEY ROOF VENT (TYP.) COM PM B B UM MSP INV DC BI AC SUB PV MODULE TYPE - HANWHA .CELL BLK ML-G10À 400 (400W) SOLAR AREA - 380.44 S FT EXISTING SOLAR AREA - 635.04 S FT ROOF AREA - 4610 S FT ROOF COVERAGE -22.03 UTILITY: GAS METER GM I SYSTEM CONTROLLER I SITE PLAN NOTES: 1. VERIFY ALL OBSTRUCTIONS AND DIMENSIONS IN THE FIELD. 2. PROVIDE RAIL SPLICES AS REUIRED BY MANUFACTURERÀS GUIDELINES. 3. NO SIGNIFICANT SHADING WILL RESULT FROM EXISTING ROOF OBSTRUCTIONS. 4. PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ATTIC, PLUMBING, FURNACE OR WATER HEATER VENTS 5. AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESSIBLE. TO BE WITHIN 10À OF THE UTILITY METER 6. 3/4À OR GREATER CONDUIT RUN (7/8À ABOVE ROOF SURFACE) 7. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. LOAD CENTER LC PV-3 DATE:8/9/2024 SITE PLAN-2 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 2307 N Towner St 8/23/2024 EW S N CALIFORNIA LICENSE NO. C83664 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA UM MS P BI GE N IN V IN V CO M AC ACB (E) CONCRETE DRIVEWAY NO R T H T O W N E R S T R E E T SWIMMING POOL (TYP.) FR O N T O F H O M E PROPERTY LINE JB JBJB GATE GATE UTILITY METER MAIN SERVICE PANEL AC DISCONNECT DC DISCONNECT AC COMBINER PANEL INVERTER BACKUP INTERFACE BATTERY PRODUCTION METER SUBPANEL JUNCTION BOX FIRE PATHWAY PROPERTY LINE ATTIC RUN CONDUIT EXTERNAL CONDUIT SATELLITE DISH SITE PLAN LEGEND MODULE SPEC AND ROOF INFO: SCALE: 1/16" = 1'-0" ROOF OBSTRUCTION (TYP.) CHIMNEY ROOF VENT (TYP.) COM PM B JB UM MSP INV DC BI AC SUB PV MODULE TYPE - HANWHA Q.CELL BLK ML-G10+ 400 (400W) SOLAR AREA - 380.44 SQ FT EXISTING SOLAR AREA - 635.04 SQ FT ROOF AREA - 4610.00 SQ FT ROOF COVERAGE -22.03% UTILITY: GAS METER GM PV-2 DATE: SCOTT E. WYSSLING, P.E. 7/26/2024 SITE PLAN-1 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 IQ SYSTEM CONTROLLER IQ SITE PLAN NOTES: 1. VERIFY ALL OBSTRUCTIONS AND DIMENSIONS IN THE FIELD. 2. PROVIDE RAIL SPLICES AS REQUIRED BY MANUFACTURER'S GUIDELINES. 3. NO SIGNIFICANT SHADING WILL RESULT FROM EXISTING ROOF OBSTRUCTIONS. 4. PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ATTIC, PLUMBING, FURNACE OR WATER HEATER VENTS 5. AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESSIBLE. TO BE WITHIN 10' OF THE UTILITY METER 6. 3/4" OR GREATER CONDUIT RUN (7/8" ABOVE ROOF SURFACE) 7. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. LOAD CENTER LC 127'-11" 81'-11" 125'-4" 82'-5" 3'-9" 36'-11" 7'-1" 17'-11" Signed 7/26/2024 2307 N Towner St 8/23/2024 EW S N ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 ÀPN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 B NO R T H T O W N E R S T R E E T FR O N T O F H O M E B BB ROOF OBSTRUCTION (TYP.) RAIL (TYP.) MOUNT (TYP.) SEE TABLE BELOW SEE TABLE BELOW FOR ROOF FRAMING SIZE ROOF SECTION 1 TILT: 20À AZIMUTH: 270À ROOF SECTION 2 TILT: 20À AZIMUTH: 180À ROOF SECTION 3 TILT: 20À AZIMUTH: 180À (E) PV SYSTEM ROOF FRAMING 24À ON CENTER 48À MAX MOUNT SPACING CHIMNEY (TYP.) (N) PV MODULE EUIPPED W/ 1 MICRO-INVERTER PER MODULE AC UM MSPBI GENINVINVCOM AC SCALE: 3/32À À 1À-0À ROOF FRAMING FRAMING SPACING ROOF TYPE MAX MOUNT SPACING MOUNT MOUNT TYPE EMBEDMENT DEPTH ROOF SECTION 1 2X4 - TRUSSES 24À CONCRETE W TILE 48À ECOFASTEN TILE HOOK FLASHING ROOF MOUNT 2-1/2À ROOF SECTION 2 2X4 - TRUSSES 24À CONCRETE W TILE 48À ECOFASTEN TILE HOOK FLASHING ROOF MOUNT 2-1/2À ROOF SECTION 3 2X4 - TRUSSES 24À CONCRETE W TILE 48À ECOFASTEN TILE HOOK FLASHING ROOF MOUNT 2-1/2À PROPERTY LINE ATTIC RUN CONDUIT EXTERNAL CONDUIT MOUNTING PLAN LEGEND RAIL MOUNT ROOF FRAMING ROOF OBSTRUCTION (TYP.) CHIMNEY ROOF VENT (TYP.) UTILITY METER MAIN SERVICE PANEL AC DISCONNECT DC DISCONNECT AC COMBINER PANEL INVERTER BACKUP INTERFACE BATTERY PRODUCTION METER SUBPANEL UNCTION BOX SATELLITE DISH COM PM B B UM MSP INV DC BI AC SUB GAS METER GM I SYSTEM CONTROLLER I LOAD CENTER LC METAL SEAMS MOUNTING PLAN NOTES: 1. VERIFY ALL OBSTRUCTIONS AND DIMENSIONS IN THE FIELD. 2. PROVIDE RAIL SPLICES AS REUIRED BY MANUFACTURERÀS GUIDELINES. 3. NO SIGNIFICANT SHADING WILL RESULT FROM EXISTING ROOF OBSTRUCTIONS. 4. PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ATTIC, PLUMBING, FURNACE OR WATER HEATER VENTS 5. ACTUAL ROOF CONDITIONS AND ROOF FRAMING (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS CANTILEVER NOTES: 1. CANTILEVER (OVERHANG) LENGTHS CAN BE UP TO 33 OF THE SPAN LENGTH. 2. THE CANTILEVER IS DEFINED AS THE DISTANCE FROM THE CENTER OF THE MOUNT TO THE EDGE OF THE RAIL PV-4 DATE:8/9/2024 MOUNTING PLAN swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 2307 N Towner St 8/23/2024 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com July 1, 2024 Exo Energy 1358 La Miranda Drive San Marcos, CA 92071 Re: Engineering Services Vandervoort Residence 2307 N Towner Street, Santa Ana, CA 7.200 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Tile Roofing Roof Slope: 20 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 13 psf o New Solar Panels and Racking = 3 psf o TOTAL = 16 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 0 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 95 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2022 California Building Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. 2307 N Towner St 8/23/2024 Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ecofasten installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2-1/2”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two 5/16” diameter lag screws with a minimum of 2-1/2” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2022 California Building Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE California License No. 83664 2307 N Towner St 8/23/2024 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com Existing Vandervoort Residence Roof Dead Load 2307 N Towner Street 9.0 psf Clay or Conc Tile Santa Ana, CA 1.6 psf 1/2" Plywood Sheathing 0.8 psf 2x4 Trusses @ 24 in. o.c. 1.0 psf Ceiling, Mechanical, Electrical 0.6 psf Miscellaneous 13.0 psf TOTAL Second Floor Dead Load 0 psf Floor Finishes 0 psf 1 1/8" Subfloor Sheathing 0 psf Joists @ 16' o.c. 0 psf Partitions 0 psf Ceiling, Mechanical, Electrical 0 psf Miscellaneous 0 psf TOTAL Roof Live Load Floor Live Load 20 psf 0 psf Roof Snow Load Ground SnowLoad=0 psf (to be divided by cosine of roof angle for horizontal projection ASCE 7 Sec. 7.4) pf = 0.7 Ce Ct I pg =0 psf Ce = 1, Ct = 1.1 Flat Roof Snow Load (ASCE 7-16 Eq. 7.3-1) Cs =0.91 ASCE 7-16 Figure 7.4-1 Additional Roof Dead Load - New Solar Panels 3 psf Roof Live Load at Solar Panels 0 psf Roof Snow Load at Solar Panels 0 psf Sloped Roof Snow Load (ASCE 7-16 Eq. 7.4-1) Total Total Existing Roof Load = (DLROOF + Max(LLROOF or S)) AreaROOF 152130 lbs Total New Roof Load = (DLROOF + DLADD + Max(LLROOF or S)) AreaROOF 145514 lbs Change in Demand = (Total New Roof Load - Existing Roof Load) / Existing Roof Load -4.35% 2021 IEBC Section 805.2 states: "Any existing gravity load-carrying structural element for which an alteration causes an increase in design gravity load of more than 5 percent shall be strengthened, supplemented, replaced or otherwise altered as needed to carry the increased gravity load required by this code for new structures." Gravity Loads Total New Gravity Loads are less than Existing Loads. OK Signed 7/01/2024 2307 N Towner St 8/23/2024 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com V =95 Basic Wind Speed Vandervoort Residence Exposure C ASCE 7-16, Section 26.7 2307 N Towner Street Kz =0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA Kzt =1 Topographic Factor, ASCE 7-16, Section 26.8.2 Kd =0.85 Directionality Factor, ASCE 7-16, Section 26.6 Ke =0.995 Ground Elevation Factor, ASCE 7-16, Section 26.9 qh =16.6 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) Roof Angle =20 deg Roof Type Hip sanchor =48 in Horizontal spacing of roof anchors Atrib =12.33 sf Panel Area tributary to each roof anchor GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 Roof Zone Zone 1 2e 2r Zone 3 -1.30 -1.79 -2.39 -1.79 ga =0.79 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 gE =1.00 Edge Array Factor, ASCE 29.4.4 edges < 0.5*building height, and panel spacing < 4ft. pnet = qhGCpgEga =Design Wind Pressure, ASCE 7-16, Equation 29.4-7 Roof Zone 1 2e 2r Zone 3 -17 psf -24 psf -31 psf -24 psf Min Pressure = -16 psf Use 17 psf Use 24 psf Use 31 psf Use 24 psf ULTIMATE x 0.6 =16 psf 16 psf 19 psf 16 psf ALLOWABLE Connection to Existing Roof Framing F.S. =1 Additional Factor of Safety applied to withdrawl force, if desired Atrib =12.3 ft2 DLpanel =3 psf Roof Zone 1 2e 2r Zone 3 Wuplift =17 psf 24 psf 31 psf 24 psf Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor Roof Zone 1 2e 2r Zone 3 -107.0 lbs -154.7 lbs -212.5 lbs -154.7 lbs Connection Capacity db =5/16 in Lag Screw diameter Dpen =2 1/2 in Lag Screw penetration into existing framing member No. of Screws 2 Screws per Connection Species of wood framing CD =1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 Ct =0.7 Temperature Factor, NDS Table 10.3.4 W =205 lb/in Withdrawl Capacity, NDS Equation 11.2-1 W' = CD x Ct x W =229 lb/in Adjusted withdrawl value Pallow = Dpen x W' =1147 lbs (Using (2) screws per connection) Roof Zone 1 2e 2r Zone 3 DEMAND =107 lbs 155 lbs 213 lbs 155 lbs CAPACITY =1147 lbs 1147 lbs 1147 lbs 1147 lbs up to72in ok up to72in ok up to72in ok up to72in ok Spruce-Pine-Fir Wind Uplift Rooftop Solar Panels Parallel to Roof Surface ASCE 7-16, Section 29.4.4 This analysis calculates the capacity of the lag screws only. For capacity of the complete mounting system, please see manufacturer's recommendations. Signed 7/01/2024 2307 N Towner St 8/23/2024 ROOF MOUNT CROSS SECTION DETAIL NTS ROOF FRAMING SEE TABLE ON SHEET PV-3 PV MODULE FINISHED ROOF GROUND END/MID CLAMP SHEATHING RAIL ECOFASTEN CLICKFIT UNIVERSAL TILE HOOK ROOF MOUNT WITH (2) SCREWS CONNECTED TO ROOF FRAMING WATERPROOF BUTYL (2) 5/16" x 4" LAG SCREWS PROVIDED BY MANUFACTURER CONNECTED INTO ROOF FRAMING EMBEDMENT DEPTH SEE TABLE ON SHEET PV-3 GENERAL ROOF MOUNT DETAIL NTS ROOF MOUNT PLAN VIEW DETAIL NTS ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA CALIFORNIA LICENSE NO. C83664 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 S-1 DATE: SCOTT E. WYSSLING, P.E. 7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 STRUCTURAL DETAILS ECOFASTEN CLICKFIT UNIVERSAL TILE HOOK FLASHING ROOF MOUNT SEE ROOF MOUNT CROSS SECTION DETAIL THIS SHEET FOR CONNECTION TO ROOF FRAMING ROOF FRAM I N G SEE TABLE O N S H E E T P V - 3 FINISHED ROOF ROOF SHEATHING PV MODULE RAIL 3" MIN - 6" MAX SPACE FROM ROOF SURFACE ECOFASTEN CLICKFIT UNIVERSAL TILE HOOK ROOF MOUNT WITH (2) SCREWS CONNECTED TO ROOF FRAMING (2) 5/16" x 4" LAG SCREWS PROVIDED BY MANUFACTURER CONNECTED INTO ROOF FRAMING 1.CONTRACTOR IS TO FOLLOW THE PLAN FOR INSTALLING ROOF MOUNTS. 2.IF THE CONTRACTOR IDENTIFIES THE ROOF FRAMING IS DIFFERENT FROM WHAT IS IDENTIFIED ON THIS PLAN, CONTRACTOR SHALL NOTIFY THE ENGINEER BEFORE PROCEEDING WITH INSTALLATION. 3.CONTRACTOR IS TO LOCATE THE ROOF FRAMING BY UTILIZING A HAMMER. 4.WHEN THE ROOF FRAMING IS LOCATED, CONTRACTOR IS TO DRILL A PILOT HOLE TO CONFIRM CENTER OF ROOF FRAMING. IF THE ROOF FRAMING IS MISSED, AND A NEW PILOT HOLE IS TO BE DRILLED, CONTRACTOR TO UTILIZE SILICON/CAULK TO SEAL THE ORIGINAL PILOT HOLE. 5.DIRECT TO DECK MOUNTS ARE ONLY TO BE USED WITH APPROVED DESIGN BY THE ENGINEER. DIRECT TO DECK MOUNT INSTALLATION IS NOT A SUBSTITUTION FOR LAG SCREWS INTO ROOF FRAMING. 6.CONTRACTOR TO FOLLOW MANUFACTURERS SPECIFICATIONS FOR INSTALLATION AND REQUIRED SCREWS. MOUNT INSTALLATION NOTES Signed 7/26/2024 2307 N Towner St 8/23/2024 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 DC AC DC AC DC AC DC AC DC AC DC AC BRANCH CIRCUIT (1): 7 MODULES (N) ENPHASE IQ COMBINER X-IQ-AM1-240-4C (N) 15A-2P ENVOY BREAKER NEW (2) 20A-2P 1 (N) NEMA 3 JUNCTION BOX 2 BRANCH CIRCUIT (2): 11 MODULES 1 L1 L2 N G G N ENPHASE IQ8PLUS-72-2-US MICROINVERTER(S) (N) NON-FUSED PV AC DISCONNECT VISIBLE, LOCKABLE, LABELED, OPEN 30A, 240V, 2-POLE 3 G (E) TESLA POWERWALL AC II BATTERY (N) 30A-2P (E) 20A-2P G N 3 = = = = = = L1 L2 G AC DC EXISTING DC CONVERTER L1 L2 N G (E) INVERTER (E) DC DISCONNECT (E) 20A-2P = = = = = = L1 L2 G (N) JUNCTION BOX AC DC L1 L2 N G (E) INVERTER (E) DC DISCONNECTEXISTING DC CONVERTER (N) JUNCTION BOX (N) 125A GENERATION PANEL 120/240V, 1-PHASE EXISTING STRING(S) EXISTING MODULE(S) EXISTING STRING(S) EXISTING MODULE(S) (N) NON-FUSED ESS DISCONNECT VISIBLE, LOCKABLE, LABELED, OPEN 30A, 240V, 2-POLE (N) 30A-2P (N) 100A-2P (N) 175A-2P (N) 100A-2P (N) 225A MAIN SERVICE PANEL (N) 175A / 2P MAIN BREAKER (E) LOADS SPD (N) SURGE PROTECTION DEVICE TYPE 1 (N) 20A-2P G N L2 L1 G N 4 EXISTING GROUNDING ELECTRODE SYSTEM POINT OF INTERCONNECTION: SINGLE BACKFED BREAKER 705.12 (B)(2)(3)(b) (E) UTILITY METER (2)#10 AWG PV-WIRE (1) #6 AWG BARE CU EGC (2)#10 AWG THWN-2 (1)#8 AWG BARE CU EGC 3/4'' EMT TYPE CONDUIT (2)#10 AWG THWN-2 (1)#8 AWG BARE CU EGC 3/4'' EMT TYPE CONDUIT (3) #10 AWG TWHN-2 (1) #8 AWG EGC/GEC (3) #10 AWG TWHN-2 (1) #8 AWG EGC/GEC SUPPLY CONNECTIONS MAIN LUGS OR MAIN BREAKER G N (E) TESLA BACKUP GATEWAY 2 200A, NEMA 3R, 120/240V (E) 100A-2P 4 Existing Module:Trina Solar TSM-270PD05.08 Existing Inverter:PVI-3.8-OUTD-US INVERTER Existing 2nd Inverter:PVI-3.8-OUTD-US INVERTER Existing Module QTY:36 Existing Interconnection:LOAD SIDE BREAKER Existing PV Breaker Amp: Existing System Output:16 x 2= 32 Existing System size:9.72 PCS SETTING SET TO 44A CT's CONDUCTOR SCHEDULE CONDUCTORS GROUND CONDUIT TAG ID WIRES IN CONDUIT WIRE AWG TYPE, MATERIAL AMPACITY SIZE TYPE, MATERIAL 1 3 #12 AWG Q CABLE 20 #6 AWG BARE, CU 2 5 #10 AWG THHN,CU 30 #8 AWG THHN,CU 3/4" CONDUIT 3 4 #10 AWG THHN,CU 30 #8 AWG THHN,CU 3/4" CONDUIT 4 4 #3 AWG THHN,CU 100 #8 AWG THHN,CU 1-1/4" CONDUIT 1. AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE, LOCKABLE AND READILY ACCESSIBLE. TO BE WITHIN 10' OF THE UTILITY METER 2. 3/4" OR GREATER CONDUIT RUN (7/8" ABOVE ROOF SURFACE 3. GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ (AUTHORITY HAVING JURISDICTION). 4. PER NEC REQUIREMENTS GROUNDING CONDUCTORS SMALLER THAN #6 AWG SHALL BE PROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64). 5. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 6. ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC 300.6 C1, 310.8 D). 7. ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. GENERAL NOTES INTEGRATED BONDING/ GROUNDING CONDUCTOR NOTES 1. ALL TERMINATIONS AND CONDUCTORS RATED FOR 75°C MINIMUM. 110.14(C)(1)(a)(3). INTERCONNECTION CALCULATIONS BUS RATING MAIN OCPD ALLOWED PV PER NEC AMPS AMPS AMPS 225A 175A 95A ITEM UNIT PANEL E-1 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 ELECTRICAL DIAGRAM EXISTING PV SYSTEM IS NOT RS COMPLIANT. 2307 N Towner St 8/23/2024 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 CONDUCTOR CALCULATIONS MODULE MANUFACTURER/ MODEL HANWHA Q.CELL BLK ML-G10+ 400 PMAX 400 W VOC 45.3 V VMP 37.13 V IMP 10.77 A ISC 11.14 A TEMPERATURE COOEFFICIENT OF PMAX -0.034 %/°C TEMPERATURE COEFFICIENT OF VOC -0.27 %/°C INVERTER MANUFACTURER/ MODEL ENPHASE IQ8PLUS-72-2-US MAX AC OUTPUT 1.21 A AC OUTPUT VOLTAGE 240 V MAX DC INPUT VOLTAGE 60 V MAX INPUT CURRENT 20 A WEIGHTED CEC EFFICIENCY 97.00% INVERTER WATTAGE 290 W TAG 1 (SEE E-1)TAG 2 (SEE E-1)TAG 3 (SEE E-1)TAG 4 (SEE E-1) UNDER MODULES, NOT IN CONDUIT #10 AWG MAX CURRENT = 30A #10 AWG MAX CURRENT = 30A #3 AWG MAX CURRENT = 100A #12 AWG MAX CURRENT = 20A ENPHASE IQ8PLUS-72-2-US MAX OUTPUT = 21.78A 8.47 A FOR CIRCUIT 1 8.47 A FOR CIRCUIT 1 21.78 * 1.25 (SAFETY FACTOR) = 27.225A 21.78 * 1.25 (SAFETY FACTOR) = 27.225A 13.31 A FOR CIRCUIT 2 13.31 A FOR CIRCUIT 2 RECOMMENDED OCPD = 30 TESLA POWERWALL OCPD = 30 EXISITING SYSTEM MAX OUTPUT= 32A 32*1.25(SAFETY FACTOR) = 40 TOTAL OUTPUT CURRENT = 27.225+30+40 = 97.225A RECOMMENDED OCPD = 100 EQUIPMENT INFORMATION E-2 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 EQUIPMENT INFORMATION 2307 N Towner St 8/23/2024 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 THE EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR RAPID SHUTDOWN SWITCH FOR SOLAR PV SECOND SOURCE IS PHTOVOLTAIC SYSTEM MAXIMUM AC OPERATING CURRENT: PHOTOVOLTAIC WARNING: PHOTOVOLTAIC POWER SOURCE PHOTOVOLTAIC AC DISCONNECT DUAL POWER SOURCE NOMINAL OPERATING AC VOLTAGE: DC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING ELECTRICAL SHOCK HAZARD DO NO TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS ! WARNING! 77.78 240 PHOTOVOLTAIC AC DISCONNECT !! LABELING NOTES: 1.LABELING REQUIREMENTS BASED ON THE 2022 CALIFORNIA ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 2.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 3.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [CEC 110.21] 4.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [CEC 690.54] AT POINT OF INTERCONNECTION. [CEC 705.12(C), 690.59] EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED [CEC. 690.13(B)] AT EACH DC DISCONNECTING MEANS [CEC 690.13(B)] AT EACH AC DISCONNECTING MEANS [CEC 690.13(B)] AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS [CEC 690.31(D)(2)] AT BUILDING OR STRUCTURE MAIN DISCONNECTING MEANS. [CEC 690.12(E), CEC 690.13(B)] A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH THAT INCLUDES THIS WORDING. THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED BACKGROUND.[CEC 690.56(C)(2)] FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. [CEC 690.56(C)(1)(A)] A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER. [CEC 705.12(B)(3)(2)] PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT E-3 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 PV LABELS PLACE LABEL AT MAIN SERVICE PANELCAUTION: DO NOT INSTALL ADDITIONAL LOADS IN THIS PANEL PLACE LABEL AT MAIN SERVICE PANEL THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING DO NOT ADD LOADS CAUTION AT EXTERNAL LOCATION NEAR METER AND UTILITY SERVICE DISCONNECT TRI POWER SOURCE SECOND SOURCE IS BATTERY THIRD SOURCE IS PHOTOVOLTAIC SYSTEM PLACE LABEL EXTERNAL AT MAIN SERVICE DISCONNECTENERGY STORAGE SYSTEM ON SITE LOCATED OUTSIDE PLACE ESS LABELS AT BATTERY AND/OR CONTROLLERWARNING ELECTRIC SHOCK IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED AT AC COMBINER PANEL. NEC 690.13(B) ON THE DEAD FRONT BELOW THE TRANSPARENT BREAKER, POSITION THE COVER FOR THE MAINS BREAKER. THE MAXIMUM CURRENT BACKFED BY THIS SYSTEM TO THE MAIN PANEL MAY BE CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. PC CONTROLLED CURRENT SETTINGS:AMPS44 2307 N Towner St 8/23/2024 UM MS P BG GE N IN V IN V CO M AC B NO R T H T O W N E R S T R E E T JB JBJB AC EW S N ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 2307 NORTH TOWNER STREET, SANTA ANA, CALIFORNIA 92706 CAUTION: LABEL LOCATION: MSP CODE REF: CEC 2022 - 705.10 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN FR O N T O F H O M E RSS EQUIPPED SOLAR ARRAY ON ROOFTOP AC COMBINER PANEL AC DISCONNECT MAIN SERVICE PANEL UTILITY METER YOU ARE HERE INVERTER WITH DC DISCONNECT E-4 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 PLACARD GENERATION PANEL BACKUP GATEWAY ESS DISCONNECTBATTERY(EXTERIOR) EXISTING PV SYSTEM IS NOT RS COMPLIANT. 2307 N Towner St 8/23/2024 TESLA BACKUP GATEWAY 2125A GENERATION PANEL TESLA POWERWALL 2 ABB PVI-3.8-OUTD-US INVERTER ABB PVI-3.8-OUTD-US INVERTER ENPHASE I COMBINER X-I-AM1-240-4C 30A ESS DISCONNECT 30A AC DISCONNECT TO GENERATION PANEL FROM ESS DISCONNECT METER MAIN ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 ÀPN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 1.EUIPMENT SHALL BE A MINIMUM OF 3À X 3À ACCESSIBLE WORKSPACE, FLAT, AND CLEAR OF DEBRIS AND OBSTACLES (TREES, BUSHES, PLANTS, ETC.) 2.BATTERIES TO BE SEPARATED BY A MINIMUM 3À BETWEEN EACH UNIT PER UL 9540A REPORT NOTES E-5 DATE:8/9/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 ELEVATION DETAIL SOUTH EXTERIOR ELEVATION DETAIL SCALE: NTS 2307 N Towner St 8/23/2024 UM MS P BG GE N IN V IN V CO M AC B JB JBJB AC VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 PV-6 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 INSTALL CHECKLIST 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-1 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 MODULE SPEC SHEET 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-2 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 INVERTER SPEC SHEET 2307 N Towner St 8/23/2024 UM MS P BG GE N IN V IN V CO M AC AC B NO R T H T O W N E R S T R E E T JB JBJB EW S N ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 2307 NORTH TOWNER STREET, SANTA ANA, CALIFORNIA 92706 CAUTION: LABEL LOCATION: MSP CODE REF: CEC 2022 - 705.10 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN FR O N T O F H O M E RSS EQUIPPED SOLAR ARRAY ON ROOFTOP AC COMBINER PANEL AC DISCONNECT MAIN SERVICE PANEL UTILITY METER YOU ARE HERE INVERTER WITH DC DISCONNECT E-4 DATE: swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 PLACARD GENERATION PANEL BACKUP GATEWAY ESS DISCONNECT BATTERY (EXTERIOR) Existing PV system is NOT RS compliant. VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 APN/PARCEL NO: 00121406 7/01/2024 2307 N Towner St 8/23/2024 ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 PV-5 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 SITE PHOTOS 2307 N Towner St 8/23/2024 B B BB AC UM MSPBI GENINVINVCOM AC VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 ÀPN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 PV-6 DATE:8/9/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 INSTALL CHECKLIST 2307 N Towner St 8/23/2024 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-1 DATE: swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 MODULE SPEC SHEET VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 APN/PARCEL NO: 00121406 7/01/2024 2307 N Towner St 8/23/2024 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-2 DATE: swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 INVERTER SPEC SHEET VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 APN/PARCEL NO: 00121406 7/01/2024 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-3 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 COMBINER PANEL SPEC SHEET 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-4 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 RAIL SPEC SHEET 2307 N Towner St 8/23/2024 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-4 DATE: swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 RAIL SPEC SHEET-1 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 APN/PARCEL NO: 00121406 7/01/2024 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-5 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 MOUNTING SPEC SHEET 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-6 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 GROUNDING SPEC 2307 N Towner St 8/23/2024 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-7 DATE: swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 BATTERY SPEC SHEET VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 APN/PARCEL NO: 00121406 7/01/2024 2307 N Towner St 8/23/2024 VANDERVOORT, DAVID 2307 NORTH TOWNER STREET SANTA ANA, CA 92706 PN/PARCEL NO: 00121406 EXO ENERGY 1358 LA MIRADA DRIVE SAN MARCOS, CA 92071 (208) 351-4153 MICHAEL ESPINOZA CSLB: 1063308 SPECS-7 DATE:7/26/2024 swyssling@wysslingconsulting.com (201) 874-3483 DESIGN ENGINEER SOLAR COMPANY/CLIENT 76 N. MEADOWBROOK DRIVE ALPINE, UTAH 84004 BATTERY SPEC SHEET 2307 N Towner St 8/23/2024 PCC-13 Rev. 06-17-2019 White-Plan Check Yellow-Applicant REVISION /SUPPLEMENTAL PLAN CHECK REQUEST PCC-13 CBC 2022 Rev 6-09-2023 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Project Address: _________________________________________ Suite #_______________________________ New Plan Check No.____________________________________________________________________________ Original Plan Check No.:__________________________________ Permit Issuance Date:____________________ Original Plan Checker: __________________________________________________________________________ Amount Paid: $__________________________________________ Misc. Receipt #: ________________________ Processed by: ___________________________________________ Date: ________________________________ Plan Checker Approval: ___________________________________ Date: ________________________________ Additional Hours:________________________________________ @ $257.88 = $ _________________________ Print Name:_____________________________________________ Signature: ____________________________ Representing: ________________________________________________________________________________ Telephone: ( ) ____________________________________ Fax: ( ) __________________________________ Contact Person: ________________________________________ Telephone: ( ) ________________________ E-mail (Strongly Recommended): _________________________________________________________________ PLANS PREPARED BY AN ARCHITECT OR ENGINEER MUST BE SIGNED BY THE PROFESSIONAL WHO PREPARES THEM. PLEASE WRITE A BRIEF DESCRIPTION OF THE REVISION/SUPPLEMENT AND IF POSSIBLE AREA OF WORK. ALL REVISIONS ARE TO BE CLOUDED AND PROPERLY IDENTIFIED: (i.e. Deltas,Sheet Numbers, etc.). Electrical, Plumbing and/or Mechanical plans – stamped job set shall accompany revised plans. ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ 2307 N Towner Street, Santa Ana, CA Scott E. Wyssling 201 874-3483 Wyssling Consulting swyssling@wysslingconsulting.com 1. Battery has been relocated for Clearances purposes see PV2, PV3, PV4, and E4. 2. 30A disconnect for the battery has been added see PV1, PV2, PV3, PV4, E1, and E4. 3. 100A main breaker added to the new 125A sub panel. See E1. 4. Structural stamps/calcs are provided. 2307 N Towner St 8/23/2024