HomeMy WebLinkAbout301 N Bewley St - PlanCOVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 301N BEWLEY ST, SANTA ANA, CA, 92703 USA SHEET NAME SHEET NUMBER PV-0 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 GENERAL NOTES x THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. x REFER TO ELECTRICAL DRAWING PV-4 FOR PANEL DETAILED INFORMATION. x IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. x THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM. x THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR TO PERFORMING THE WORK. x ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES. x DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY. x LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. x LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. x DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION PANEL. x ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE BONDED. x PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. x RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE DC DISCONNECT. ELECTRICAL NOTES x ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. x ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 & 75 DEGREE C WET ENVIRONMENT. x WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. x WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. x DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. x WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. x ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. x MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. x MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E.G.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. x THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE INTERCONNECTION METHOD : BACKFEED BREAKER MSP UPGRADE: YES EXISTING MSP INFORMATION (E) 100A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER ROOF TYPE: - COMP SHINGLES NUMBER OF LAYERS: - 01 ROOF FRAME: - 2"X4"RAFTERS @ 24" O.C. STORY: - ONE STORY SNOW LOAD : - 0 PSF WIND SPEED :- 110 MPH WIND EXPOSURE:- C RISK CATEGORY:- II COORDINATE:- 33.747074, -117.917751 DESIGN CRITERIA: 19 MODULES-ROOF MOUNTED - 7.600 kWDC, 6.988 CEC kWAC SHEET INDEX PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3, 3.1 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM WITH CALCULATION PV-5 WARNING LABELS & PLACARD PV-6+ EQUIPMENT SPEC SHEETS 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA GREEN BUILDING CODE (CGBC) 2022 CALIFORNIA HISTORICAL BUILDING CODE (CHBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ENERGY CODE (CEC) GOVERNING CODES: SYSTEM SUMMARY: (N) 19 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (N) 01 - SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTER (N) 19 - SOLAREDGE S440 POWER OPTIMIZERS (N) JUNCTION BOX (N) 125A MAIN SERVICE PANEL WITH (N) 100A MAIN BREAKER (N) SURGE-PROTECTIVE DEVICE NOTE: INSTALLER TO DETERMINE OPTIMAL CONDUIT RUN ON SITE. ATTIC RUN IS OPTIONAL UNLESS REQUIRED BELOW. ATTIC RUN: OPTIONAL 6/30/2024 6WDPSHG 06/02/2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101115942 Elec# 20180375 Issued 07/26/23 301 N Bewley St 07/28/23 ~136.04' ~5 0 . 0 1 ' ~136.04' ~5 0 . 0 1 ' 21'-1" 2' - 5 " 51'-3" 16 ' - 1 " MS P UM INV JB 1' - 1 0 " 27'-0" JB MS P UM INV SITE PLAN WITH ROOF PLAN SHEET NAME SHEET NUMBER PV-1 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023 REVISION SITE PLAN WITH ROOF PLAN 1 SCALE: 3/32" = 1'-0" NOTE: A. ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ SUPPLY OR DEMAND PIPING. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) LEGEND JUNCTION BOXJB MSP MAIN SERVICE PANEL GATE FENCE TREES SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTERINV UTILITY METERUM VENT, ATTIC FAN (ROOF OBSTRUCTION) CHIMNEY PROPERTY LINE ONE- STORY HOUSE EXISTING DRIVEWAY N B E W L E Y S T (E) STRUCTURE TYP. ROOF ACCESS POINT ROOF ACCESS POINT A 6WDPSHG07/19/2023 6/30/2024 301 N Bewley St 07/28/23 11 ' - 1 " 19 ' - 8 " 13 ' - 7 " 10'-5" 6'-6" 9'-9" 10'-8" 13'-1" 3'-2" 9" 12 ' - 7 " 1' - 7 " 2'-4" 6'-3" 3'-9" MS P UM INV JB 4'-0" SHEET NAME SHEET NUMBER PV-2 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 1/8" = 1'-0"1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 19 MODULES MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULE WEIGHT = 48.5 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.30 PSF x PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS DISTRIBUTED DEAD LOAD = 2.56 PSF AVERAGE ROOF POINT DEAD LOAD = 23.85 LBS TOTAL SYSTEM WEIGHT: 1025.36 LBS ARRAY AREA & ROOF AREA CALC'S AREA OF NEW ARRAY (Sq. Ft.) AREA OF ROOF(PLAN VIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 401.30 2267.34 17.70% NOTE: APPROVED ROOF ATTACHMENT OPTIONS INDICATED ON PV-3 & PV-3.1 ATTACHMENT DETAILS PAGE(S) BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 10 UNIRAC SM LIGHT RAIL 168" MILL SPLICE 02 BND SPLICE BAR PRO SERIES MILL MID CLAMP 28 UNIVERSAL AF SERIES MID CLAMP END CLAMP 20 UNIVERSAL AF SERIES END CLAMP ATTACHMENT 43 UNIRAC FLASHLOC OR FLASHKIT PRO (OPTIONAL) GROUNDING LUG 05 GROUND LUG MICROINVERTER MOUNTING 19 MICRO MNT BND T-BOLT 1/4IN X 3/4IN SS NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 11 232.33 542.86 42.80 #2 02 42.24 167.12 25.28 #3 06 126.73 429.01 29.54 ROOF DESCRIPTION ROOF TYPE COMP SHINGLES ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 18°180°2"X4" 24" O.C. #2 18°180°2"X4" 24" O.C. #3 18°270° 2"X4" 24" O.C. LEGEND VENT, ATTIC FAN (ROOFOBSTRUCTION) CHIMNEY ROOF ATTACHMENT UNIRAC FLASHLOC OR FLASHKIT PRO @ 48" O.C. RAFTERS JUNCTION BOXJB MSP MAIN SERVICE PANEL FIRE PATHWAY UNIRAC SM LIGHT RAIL SOLAREDGE S440 POWER OPTIMIZERS SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTERINV UTILITY METERUM RE A R Y A R D N B E W L E Y S T FR O N T Y A R D 18" FIRE PATHWAY 18 " FI R E P A T H W A Y 36 " F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY 18" FIRE PATHWAY 18" FIRE P ATH W A Y 18" FIR E P ATH W A Y 36 " F I R E P A T H W A Y ROOF #1 ROOF #2 ROOF #3 18" FIR E P A T H W A Y 18" F I RE PAT H W A Y 6/30/2024 6WDPSHG 06/02/2023 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-3 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS SS SERRATED FLANGE NUT (N) PV MODULE (N) PV MODULE ENLARGED VIEW UNIRAC FLASHLOC BASE MILL SS SERRATED T-BOLT UNIRAC SM LIGHT RAIL 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND SS EPDM WASHER (E) 2"X4" RAFTE R S @ 24" O.C. ~4 " 2.5" MIN. EMBEDMENT ~4 " (E) COMP SHINGLES ROOF (E) COMP SHINGLES ROOF ROOF / DECK MEMBRANE BUILDING STRUCTURE END / MID CLAMP 1.26 " 1.2 6 " 6/30/2024 6WDPSHG 06/02/2023 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-3.1 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS (E) 2" X 4 " RAFTE R S @ 24" O.C ENLARGE VIEW (N) PV MODULES ~4 " PV MODULES UNIRAC SM LIGHT RAIL L-FOOT 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND SS EPDM WASHER UNIRAC FLASH KIT PRO BUILDING STRUCTURE ROOF / DECK MEMBRANE 2.5" MIN. EMBEDMENT ~4 " (E) COMP SHINGLES ROOF COMP SHINGLES ROOF END / MID CLAMP 1. 2 6 " 1.26 "6/30/2024 6WDPSHG 06/02/2023 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-4 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM ELECTRICAL LINE DIAGRAM WITH CALCULATION ELECTRICAL LINE DIAGRAM WITH CALCULATION SCALE: NTS1 #2 #1#10 DC AC #2 #1#09 10 MODULES CONNECTED IN STRING #1 09 MODULES CONNECTED IN STRING #2 (N) SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S (240V) OUTPUT: 240 VAC,25.0A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT G (N) JUNCTION BOX A B AMBIENT TEMPERTURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%) CONDUCTOR TEMPERATURE RATE (ON ROOF) CONDUCTOR TEMPERATURE RATE (OFF ROOF) 2°31°90°75° C (N) 125A MAIN SERVICE PANEL WITH (N) 100A MAIN BREAKER (TOP FED) L EXISTING GROUNDING SYSTEM (N) 40A PV BREAKER 100A 40A BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz INTERCONNECTION 120% RULE - CEC 705.12(b)(3)(2) UTILITY FEED + SOLAR BACKFEED 100A + 40A = 140A BUSS RATING x 120% 125A x 120% = 150A SOLAREDGE POWER OPTIMIZER S440 RATED DC INPUT POWER - 440 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 14.50 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM SOLAREDGE OPTIMIZERS HAVE INTEGRATED RAPID SHUT DOWN SERVICE FEED SOURCE: SCE 240V N/A SERVICE INFO. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) WIRE TAG CONDUIT WIRE QTY WIRE GAUGE WIRE TYPE TEMP. RATING WIRE AMPACITY (A) TEMP. DERATE CONDUIT FILL DERATE DERATED AMPACITY (A) ISC DESIGN CURRENT (A) GROUND SIZE GROUND WIRE TYPE A OPEN AIR 4 10 AWG PV-WIRE 90°C 40 0.96 0.8 38.40 15 15 06 AWG BARE CU GND B 3/4" EMT 4 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 15 15 10 AWG THWN-2 C 3/4" EMT 3 8 AWG THWN-2 75°C 50 0.94 1.0 47.00 -25.0 10 AWG THWN-2 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC TEMPERATURE COEFFICIENT OF Voc # OF MODULES HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+(400W)37.13 10.77 45.30 11.14 -0.27%/°C 19 MODULE DIMENSION 74.0" L x 41.1" W x 1.26"D INVERTER SPECIFICATIONS MANUFACTURER / MODEL # QUANTITY NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S 01 240 VAC 25.0A SYSTEM SIZE:- 19 X 400W = 7.600 KWDC 19 X 371.5W X 0.99 = 6.988 CEC KWAC MSP UPGRADE: YES EXISTING MSP INFORMATION (E) 100A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER (N) SURGE-PROTECTIVE DEVICE (AS PER 2020 NEC 230.67(A) & (D)) 20A-50A SURGE-PROTECTIVE DEVICE BREAKER NOTE: PV BREAKER CALCULATION (25.0X1.25X01=31.25~40A) (N) SURGE-PROTECTIVE DEVICE 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-5 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM WARNING LABELS & PLACARD LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(D)(2) LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER CEC 705.12(B)(3)(3) & CEC 690.59) NOTES AND SPECIFICATIONS: x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. x LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. x DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: CEC 706.15 (C)(4) & CEC 690.13(B) 25.0 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): 2022 CEC 690.56(C) 2022 CFC 1204.5.1 ! 4" 3" PHOTOVOLTAIC AC DISCONNECT WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.13(B)) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: CEC 690.13(B)) THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: CEC 705.12(B)(3)(3) LABEL LOCATION: MSP (PER CODE: CEC 705.12(D) & CEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING CEC 705.12 (B)(3)(2) ! ! ! LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2) WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! LABEL LOCATION: INVERTER PER CODE: CEC 690.31(E) CAUTION ! MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER-. POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . A V V A 20.00 380 480 30 LABEL LOCATION: DC DISCONNECT, INVERTER# (PER CODE: CEC 690.53) 301 N BEWLEY ST (N) PV ARRAY (E) UTILITY METER (N) 125A MAIN SERVICE PANEL WITH (N) 100A MAIN BREAKER (N) INVERTER 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-6 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-7 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-8 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-9 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-10 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-10.1 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-11 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-12 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 SHEET NAME SHEET NUMBER PV-13 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM SPEC SHEETS 301 N Bewley St 07/28/23 Hello, I, Michael Corday, have contracted with Powur PBC to install solar panels at my home at 301 N Bewley St Santa Ana, CA 927036. They are authorized to permit this project on my behalf through Santa Ana City. Thank you, Michael Corday kella079@gmail.com Phone: (714) 351-2986 Signature: Date Signed: DocuSign Envelope ID: 44056FC9-E554-4ACE-B302-9CD1B4029038 6/9/2023 301 N Bewley St 07/28/23 Certificate Of Completion Envelope Id: 44056FC9E5544ACEB3029CD1B4029038 Status: Completed Subject: Complete with DocuSign: 280233_Corday_Homeowner Authorization.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 1 Initials: 0 Permitting Team AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 2683 Via De La Valle #G321 Del Mar, CA 92014 permitting@powur.com IP Address: 68.108.34.67 Record Tracking Status: Original 6/9/2023 2:22:37 PM Holder: Permitting Team permitting@powur.com Location: DocuSign Signer Events Signature Timestamp Michael Corday kella079@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 172.58.23.119 Signed using mobile Sent: 6/9/2023 2:22:38 PM Viewed: 6/9/2023 4:51:57 PM Signed: 6/9/2023 4:52:10 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Mike Felber mike.felber@powur.com Security Level: Email, Account Authentication (None) Sent: 6/9/2023 2:22:37 PM Viewed: 6/9/2023 2:22:37 PM Signed: 6/9/2023 2:22:37 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 6/9/2023 2:22:38 PM Certified Delivered Security Checked 6/9/2023 4:51:57 PM Signing Complete Security Checked 6/9/2023 4:52:10 PM Completed Security Checked 6/9/2023 4:52:10 PM Payment Events Status Timestamps 301 N Bewley St 07/28/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST S OL-01 C BC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: Th e licensed contractor of record sh all com plete all sections, answer the ten qu estions and sign the certification section below. A copy of th is form shall be attach ed to each of TWO sets of plans, of m inim um 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will th e PV system layou t provide the required three -foot wide clear access pathways per S ection 605.11 of th e C alifornia Fire C ode, and is this sh own on the roof plan? 2. Will th e PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flu sh m ounted to the existing roof so that the plane of th e m odules (panels) are parallel to th e plane of th e roof? 4. Will the PV system weig h m axim um 4 pounds per squ are fee t or less? 5. Will th e PV system be installed where the m odules do not overh ang any roof edg es (such as eaves, g abled ends, ridg es and hips)? 6. Will th e PV system be installed with a space of 2” m inim um to 10” m axim um betwee n th e underside of m odule s and th e surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system ? 8. Will th e anchors be installed with a m axim um horizontal anch or spacing of 6 feet and is this m axim um h orizontal spacing sh own on the plans? 9. Will th e m inim um 5/16” lag screw s be installed with a m inim um of 2-1/2 inch em bedm ent into roof rafters (with pre-drilled holes) and is this m inim um em bedm en t shown on the plans? 10. Are ALL th e structu ral pages of th e plans stam ped and signed by a C alifornia licensed professional eng ineer? (including project specific site plan, P V layou t, anchorage spacing , anchorage details and m anufactu rer’s PV support inform ation.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Nam e: S ignatu re: P h one Num ber: Date: Em ail Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Powur, PBC Inc 1060243 Mike Felber 541-891-6175 mike.felber@powur.com 301 N Bewley St 6/12/2023 301 N Bewley S t 07/28/23 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 301 N Bewley St 07/28/23 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? NYes N No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? NYes N No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? N Yes N No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. ✔ Yes, COMP SHINGLES ✔ caulk ✔ unirac Flash Loc 1025.36 76 13.49 48 401.30 2.5 301 N Bewley St 07/28/23 ~136.04' ~5 0 . 0 1 ' ~136.04' ~5 0 . 0 1 ' 21'-1" 2' - 5 " 51'-3" 16 ' - 1 " MS P UM INV JB 1' - 1 0 " 27'-0" JB MS P UM INV SITE PLAN WITH ROOF PLAN SHEET NAME SHEET NUMBER PV-1 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023 REVISION SITE PLAN WITH ROOF PLAN 1 SCALE: 3/32" = 1'-0" NOTE: A. ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ SUPPLY OR DEMAND PIPING. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) LEGEND JUNCTION BOXJB MSP MAIN SERVICE PANEL GATE FENCE TREES SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTERINV UTILITY METERUM VENT, ATTIC FAN (ROOF OBSTRUCTION) CHIMNEY PROPERTY LINE ONE- STORY HOUSE EXISTING DRIVEWAY N B E W L E Y S T (E) STRUCTURE TYP. ROOF ACCESS POINT ROOF ACCESS POINT A 6WDPSHG07/19/2023 6/30/2024 301 N Bewley St 07/28/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram &RQWUDFWRU1DPH $GGUHVVDQG3KRQH BBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBB 2QH/LQH6WDQGDUG(OHFWULFDO'LDJUDPIRU 6PDOO6FDOH6LQJOH3KDVH396\VWHPV 6LWH1DPHBBBBBBBBBBBBBBBBBBBBBBBBB 6LWH$GGUHVVBBBBBBBBBBBBBBBBBBBBBBB 6\VWHP$&6L]HBBBBBBBBBBBBBBBBBBBB ^/&^DEK t'EK Zs ϭ͘ϭ ^>Ed^ĂƚĞ͗^,d ƌĂǁŶLJ͗ ŚĞĐŬĞĚLJ͗ '(6&5,37,2125&21'8&7257<3( 86(RU39:,5( %$5(&233(5(4*5'&21' (*& 7+:1RU;++:RU5+: 7+:1RU;++:RU5+: ,168/$7('(*& '&*5281',1*(/(&752'(&21' 7+:1RU;++:RU5+: ,168/$7('(*& d' ϭ Ϯ ϯ ϰ ϱ KEh/dEKEhdKZ^,h> &21' *$8*( 180%(52) &21'8&7256 KEh/d dzW Eͬ Eͬ &21'8,7 6,=( 1$ 1$ '(6&5,37,21 62/$53902'8/( 39$55$< -%2; ,)86(' &20%,1(5 ,)86(' '&',6&211(&7 '&$&,19(57(5 *(10(7(5 ,)86(' $&',6&211(&7 ,)86(' 6(59,&(3$1(/ d' ϭ Ϯ ϯ ϰ ϱ ϲ ϳ ϴ ϵ 3$57180%(5 127(6 BBBBB9$&BBBBBB$0$,1BBBBBB$%86BBBBBB$,19(57(52&3' 6((127()25,19(57(52&3'V$/626((*8,'(6(&7,21 )258186('6(5,(6675,1*6 3871$´LQ%/$1.$%29( 6((*8,'($33(1',;&)25 ,1)250$7,212102'8/($1' $55$<*5281',1* BBBBBBBB02'8/(6,1 6(5,(66285&(&,5&8,7 BBBBBBBB02'8/(6,1 6(5,(66285&(&,5&8,7 BBBBBBBB02'8/(6,1 6(5,(66285&(&,5&8,7 BBBBBBBB02'8/(6,1 6(5,(66285&(&,5&8,7 /^K /EsZdZ /^K D %8,/',1* *5281',1* (/(&752'( ' 'LVUHJDUGLI SURYLGHGZLWK LQYHUWHU KD/EZ D hd/>/dz ^Zs/ D/E^Zs/WE> D/E KW /EsZdZ KW :ͲKy ϭ ϭ ϯ ϰ ϱ ϲ ϳ ϵ Ϯ ϯ ϰ ϱ ϴ Ϯ Yh/WDEd^,h> HANWHA Q CELLS Q.PEAK DUO BL HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) 1 junction box SE6000H-US RGM W/ INTERNAL CT SE6000H-US RGM W/INTERNAL CT'S INVERTER 100 40125 10 9 ■10 4 ■10 4 ■ 10 3 280233_Corday_PV 301 N Bewley St 6.988 Powur, PBC Inc 2683 Via De La Valle Ste 321G Del Mar CA 92014 541-891-6175 301 N Bewley St 07/28/23 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40 oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) HANWHA Q CELLS 20 Q.PEAK DUO BLK ML-G10.A+( 380 10.77 480 30 11.14 45.30 37.13 40 480 400 6000 240 -0.27 SOLAREDGE SE6000H-US RGM 25 240 25 1 ■ 280233_Corday_PV 301 N Bewley St 6.988 Powur, PBC Inc 2683 Via De La Valle Ste 321G Del Mar CA 92014 541-891-6175 301 N Bewley St 07/28/23 Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com Design Criteria: Subject: Structural Certification for Installation of Residential Solar re job: Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout.  Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability.  The design criteria and structural adequacy are summarized below: 06-02-2023 06-02-2023 Powur PBC Michael Corday Powur PBC ROOF 1: Shingle roofing supported by 2x4 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 18 degrees and has a max beam span of 12.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Code: 2022 CBC, ASCE 7-16, Ult Wind Speed: 110 mph, Exposure Category: C , Ground Snow: 0 psf, Min Snow Roof: 0 psf 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 2683 Via De La Valle #321G 301 N Bewley St, Santa Ana, CA 92703, USA 301 N Bewley St 07/28/23 Attn.: To Whom It May Concern re job: The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Design Criteria: Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com 06-02-2023 Page 1 of 8 06-02-2023 Powur PBC 2683 Via De La Valle #321G Michael Corday 301 N Bewley St, Santa Ana, CA 92703, USA I certify that the roof structure has sufficient structural capacity for the applied PV loads. Code: 202 2 CBC, ASCE 7-16, Live Load: 20 psf Ult Wind Speed: 110 mph Exposure Cat: C Ground Snow: 0 psf Min Snow Roof: N/A 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 Roof Properties: Roof Type = Roof Pitch (deg) = Mean Root Height (ft) = Attachment Trib Width (ft) = Attachment Spacing (ft) = Framing Type = Framing Size = Framing OC Spacing (in.) = Section Thickness, b (in) = Section Depth, d (in) = Section Modulus, Sx (in3) = Deflection Limit D+L (in) = Deflection Limit S or W (in) = Attachments Pattern = Framing Upgrade = Sister Size = Wood Species = Wood Fb (psi) = Wood Fv (psi) = Wood E (psi) = CD (wind) = Cd (snow) = CLS = CM = Ct = CL = C i = CF = Cfu = Cr = F'b wind (psi) = F'b snow (psi) = F'v wind (psi) = F'v snow (psi) = M allowable wind (lb-ft) = M allowable snow (lb-ft) = V allowable wind (lbs) = V allowable snow (lbs) = E' (psi) = Moment of Inertia, lx (in ) = Unsupported Span (ft) = Upper Chord Length (ft) = Page 2 of 8 Shingle 18.0 13.0 3.25 4.0 Rafter 2x4 24.0 1.5 3.5 3.062 5.359 12.0 3.8 2.533 Fully Staggered No NA DF 900.0 180.0 1600000.0 1.6 1.15 1.0 1.0 1.5 1.0 1.15 2484.0 1785.37 288.0 207.0 633.94 455.64 1008.0 724.5 Roof 1 1600000.0 19.0 Michael Corday 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 Load Calculation: Dead Load Calculations: Panels Dead Load (psf) = Roofing Weight (psf) = Decking Weight (psf) = Framing Weight (psf) = Misc. Additional Weight (psf) = Existing Dead Load (psf) = Total Dead Load (psf) = Wind Load Calculations: Ultimate Wind Speed (mph) = Directionality Factor, kd = Topographic Factor, kzt = Velocity Press Exp Factor, kz = Velocity Pressure, qz (psf) = External Pressure Up, GCp_1 = External Pressure Up, GCp_2 = External Pressure Up, GCp_3 = External Pressure Down, GCp = Design Pressure Up, p_1 (psf) = Design Pressure Up, p_2 (psf) = Design Pressure Up, p_3 (psf) = Design Pressure Down, p (psf) = Snow Load Calculations: Ground Snow Load, pg (psf) = Min Flat Snow, pf_min (psf) = Sloped Snow, ps_min (psf) = Snow Importance Factor, Ic = Exposure Factor, Ce = Thermal Factor, Ct = Flat Roof Snow, pf (psf) = Slope Factor, Cs = Sloped Roof Snow, ps (psf) = Page 3 of 8 3.0 3.0 2.0 0.602 1.0 6.602 9.602 110.0 0.85 1.0 0.849 22.351 -2.0 -2.569 -3.058 0.465 -30.844 -39.624 -47.163 16.0 Roof 1 0.0 0.0 0.0 1.0 0.9 1.1 0.0 1.0 0.0 Michael Corday 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 Lag Screw Checks: Ref. Withdrawal Value, W (lb/in) = (Cm = Ct = Ceg = 1.0) CD = Adjusted Withdrawal Value, W' (lb/in) = Lag Penetration, p (in.) = Allowable Withdrawal Force, W'p (lbs) = Applied Uplift Force (lbs) = Uplift DCR = Ref. Lateral Value, Z (lbs) = (Cm = Ct = CΔ = Ceg = 1.0) CD = Adjusted Lateral Value, Z' (lbs) = Applied Lateral Force (lbs) = Angle of Resultant Force, α (deg) = Adjusted Interaction Lateral Value, Z'α (lbs) = Lateral DCR = Page 4 of 8 Roof 1 266.0 0.9 243.0 12.052 1.522 1055.397 0.011 266.0 1.6 425.6 2.5 1064.0 -245.059 0.23 Michael Corday 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 Roof Framing Checks: LC1: D+S Force Checks: Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC2: D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC3: D+0.75(S+0.6W) Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC4: 0.6D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = Page 5 of 8 Michael Corday 262.0 136.0 456.0 724.0 0.574 0.188 Roof 1 523.0 272.0 634.0 1008.0 0.825 0.27 458.0 238.0 634.0 1008.0 0.722 0.236 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 419.0 218.0 634.0 1008.0 0.66 0.216 301 N Bewley St 07/28/23 LC2: S LC3: W (Down) Deflection Checks (Service Level): LC1: D+L LC4: W (Up) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Page 6 of 8 2.403 3.8 0.632 0.0 2.533 0.0 0.405 2.533 0.16 0.78 2.533 0.308 Michael Corday 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 (Existing W + Additional W)/(Existing W) = Weight Increase: Existing Weight: Total Additional PV Weight (lbs) = Seismic Check: The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Wall Weight (psf) = Tributary Wall Area (ft2) = Total Wall Weight (lbs) = Roof Weight (psf) = Roof Area (ft2) = Total Roof Weight (lbs) = Total Existing Weight (lbs) = Page 7 of 8 17.0 970.0 16490.0 6.602 2322.0 15328.828 31818.828 1222.65 1.038 Michael Corday 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 Limits of Scope of Work and Liability: The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgments. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. This analysis is not stamped for water leakage. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. Page 8 of 8 Michael Corday 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 301 N Bewley St 07/28/23 301 N Bewley St 07/28/23 COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 301N BEWLEY ST, SANTA ANA, CA, 92703 USA SHEET NAME SHEET NUMBER PV-0 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 GENERAL NOTES x THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. x REFER TO ELECTRICAL DRAWING PV-4 FOR PANEL DETAILED INFORMATION. x IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. x THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM. x THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR TO PERFORMING THE WORK. x ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES. x DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY. x LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. x LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. x DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION PANEL. x ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE BONDED. x PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. x RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE DC DISCONNECT. ELECTRICAL NOTES x ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. x ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 & 75 DEGREE C WET ENVIRONMENT. x WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. x WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. x DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. x WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. x ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. x MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. x MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E.G.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. x THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE INTERCONNECTION METHOD : BACKFEED BREAKER MSP UPGRADE: YES EXISTING MSP INFORMATION (E) 100A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER ROOF TYPE: - COMP SHINGLES NUMBER OF LAYERS: - 01 ROOF FRAME: - 2"X4"RAFTERS @ 24" O.C. STORY: - ONE STORY SNOW LOAD : - 0 PSF WIND SPEED :- 110 MPH WIND EXPOSURE:- C RISK CATEGORY:- II COORDINATE:- 33.747074, -117.917751 DESIGN CRITERIA: 19 MODULES-ROOF MOUNTED - 7.600 kWDC, 6.988 CEC kWAC SHEET INDEX PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3, 3.1 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM WITH CALCULATION PV-5 WARNING LABELS & PLACARD PV-6+ EQUIPMENT SPEC SHEETS 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA GREEN BUILDING CODE (CGBC) 2022 CALIFORNIA HISTORICAL BUILDING CODE (CHBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ENERGY CODE (CEC) GOVERNING CODES: SYSTEM SUMMARY: (N) 19 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (N) 01 - SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTER (N) 19 - SOLAREDGE S440 POWER OPTIMIZERS (N) JUNCTION BOX (N) 125A MAIN SERVICE PANEL WITH (N) 100A MAIN BREAKER (N) SURGE-PROTECTIVE DEVICE NOTE: INSTALLER TO DETERMINE OPTIMAL CONDUIT RUN ON SITE. ATTIC RUN IS OPTIONAL UNLESS REQUIRED BELOW. ATTIC RUN: OPTIONAL 6/30/2024 STAMPED 09/08/2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. REVISION TO Bldg# 101115942 Issued 07/26/23 Bldg# 101116645 Issued 09/13/23 301 N Bewley St 09/14/23 ~136.04' ~5 0 . 0 1 ' ~136.04' ~5 0 . 0 1 ' 21'-1" 2' - 5 " 51'-3" 16 ' - 1 " MS P UM INV JB 1' - 1 0 " 27'-0" JB MS P UM INV SITE PLAN WITH ROOF PLAN SHEET NAME SHEET NUMBER PV-1 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B SITE PLAN WITH ROOF PLAN 1 SCALE: 3/32" = 1'-0" NOTE: A. ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ SUPPLY OR DEMAND PIPING. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) LEGEND JUNCTION BOXJB MSP MAIN SERVICE PANEL GATE FENCE TREES SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTERINV UTILITY METERUM VENT, ATTIC FAN (ROOF OBSTRUCTION) CHIMNEY PROPERTY LINE ONE- STORY HOUSE EXISTING DRIVEWAY N B E W L E Y S T (E) STRUCTURE TYP. ROOF ACCESS POINT ROOF ACCESS POINT A B 6/30/2024 STAMPED 09/08/2023 STRUCTURAL NOTES : 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMINGSUPPORTING THE PROPOSED PV INSTALLATION ONLY. 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 2x4 RAFTERS @ 24" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 10 FT. 301 N Bewley St 09/14/23 11 ' - 1 " 19 ' - 8 " 13 ' - 7 " 9'-7" 9'-10" 7'-3" 10'-8" 13'-1" 3'-2" 9" 12 ' - 7 " 1' - 7 " 2'-4" 6'-3" 3'-9" MS P UM INV JB 4'-0" SHEET NAME SHEET NUMBER PV-2 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 1/8" = 1'-0"1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 19 MODULES MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULE WEIGHT = 48.5 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.30 PSF x PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS DISTRIBUTED DEAD LOAD = 2.55 PSF AVERAGE ROOF POINT DEAD LOAD = 24.98 LBS TOTAL SYSTEM WEIGHT: 10224.30 LBS ARRAY AREA & ROOF AREA CALC'S AREA OF NEW ARRAY (Sq. Ft.) AREA OF ROOF(PLAN VIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 401.30 2267.34 17.70% NOTE: APPROVED ROOF ATTACHMENT OPTIONS INDICATED ON PV-3 & PV-3.1 ATTACHMENT DETAILS PAGE(S) BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 10 UNIRAC SM LIGHT RAIL 168" MILL SPLICE 02 BND SPLICE BAR PRO SERIES MILL MID CLAMP 28 UNIVERSAL AF SERIES MID CLAMP END CLAMP 20 UNIVERSAL AF SERIES END CLAMP ATTACHMENT 41 UNIRAC FLASHLOC OR FLASHKIT PRO (OPTIONAL) GROUNDING LUG 05 GROUND LUG MICROINVERTER MOUNTING 19 MICRO MNT BND T-BOLT 1/4IN X 3/4IN SS NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 10 211.21 542.86 38.91 #2 03 63.36 167.12 37.91 #3 06 126.73 429.01 29.54 ROOF DESCRIPTION ROOF TYPE COMP SHINGLES ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 18°180°2"X4" 24" O.C. #2 18°180°2"X4" 24" O.C. #3 18°270° 2"X4" 24" O.C. LEGEND VENT, ATTIC FAN (ROOFOBSTRUCTION) CHIMNEY ROOF ATTACHMENT UNIRAC FLASHLOC OR FLASHKIT PRO @ 48" O.C. RAFTERS JUNCTION BOXJB MSP MAIN SERVICE PANEL FIRE PATHWAY UNIRAC SM LIGHT RAIL SOLAREDGE S440 POWER OPTIMIZERS SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S INVERTERINV UTILITY METERUM RE A R Y A R D N B E W L E Y S T FR O N T Y A R D 18" FIRE PATHWAY 18 " FI R E P A T H W A Y 36 " F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY 18" FIRE PATHWAY 18" FIRE P ATH W A Y 18" FIR E P ATH W A Y 36 " F I R E P A T H W A Y ROOF #1 ROOF #2 ROOF #3 18" FIR E P A T H W A Y 18" F I RE PAT H W A Y B B B B 6/30/2024 STAMPED 09/08/2023 301 N Bewley St 09/14/23 SHEET NAME SHEET NUMBER PV-3 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS SS SERRATED FLANGE NUT (N) PV MODULE (N) PV MODULE ENLARGED VIEW UNIRAC FLASHLOC BASE MILL SS SERRATED T-BOLT UNIRAC SM LIGHT RAIL 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND SS EPDM WASHER (E) 2"X4" RAFTE R S @ 24" O.C. ~4 " 2.5" MIN. EMBEDMENT ~4 " (E) COMP SHINGLES ROOF (E) COMP SHINGLES ROOF ROOF / DECK MEMBRANE BUILDING STRUCTURE END / MID CLAMP 1.26 " 1.2 6 " 6/30/2024 STAMPED 09/08/2023 301 N Bewley St 09/14/23 SHEET NAME SHEET NUMBER PV-3.1 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS (E) 2" X 4 " RAFTE R S @ 24" O.C ENLARGE VIEW (N) PV MODULES ~4 " PV MODULES UNIRAC SM LIGHT RAIL L-FOOT 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND SS EPDM WASHER UNIRAC FLASH KIT PRO BUILDING STRUCTURE ROOF / DECK MEMBRANE 2.5" MIN. EMBEDMENT ~4 " (E) COMP SHINGLES ROOF COMP SHINGLES ROOF END / MID CLAMP 1. 2 6 " 1.26 "6/30/2024 STAMPED 09/08/2023 301 N Bewley St 09/14/23 SHEET NAME SHEET NUMBER PV-4 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B ELECTRICAL LINE DIAGRAM WITH CALCULATION ELECTRICAL LINE DIAGRAM WITH CALCULATION SCALE: NTS1 #2 #1#10 DC AC #2 #1#09 10 MODULES CONNECTED IN STRING #1 09 MODULES CONNECTED IN STRING #2 (N) SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S (240V) OUTPUT: 240 VAC,25.0A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT G (N) JUNCTION BOX A B AMBIENT TEMPERTURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%) CONDUCTOR TEMPERATURE RATE (ON ROOF) CONDUCTOR TEMPERATURE RATE (OFF ROOF) 2°31°90°75° C (N) 125A MAIN SERVICE PANEL WITH (N) 100A MAIN BREAKER (TOP FED) L EXISTING GROUNDING SYSTEM (N) 40A PV BREAKER 100A 40A BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz INTERCONNECTION 120% RULE - CEC 705.12(B)(3)(2) UTILITY FEED + SOLAR BACKFEED 100A + 31.25A = 131.25A BUSS RATING x 120% 125A x 120% = 150A SOLAREDGE POWER OPTIMIZER S440 RATED DC INPUT POWER - 440 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 14.50 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM SOLAREDGE OPTIMIZERS HAVE INTEGRATED RAPID SHUT DOWN SERVICE FEED SOURCE: SCE 240V N/A SERVICE INFO. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF) WIRE TAG CONDUIT WIRE QTY WIRE GAUGE WIRE TYPE TEMP. RATING WIRE AMPACITY (A) TEMP. DERATE CONDUIT FILL DERATE DERATED AMPACITY (A) ISC DESIGN CURRENT (A) GROUND SIZE GROUND WIRE TYPE A OPEN AIR 4 10 AWG PV-WIRE 90°C 40 0.96 0.8 38.40 15 15 06 AWG BARE CU GND B 3/4" EMT 4 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 15 15 10 AWG THWN-2 C 3/4" EMT 3 8 AWG THWN-2 75°C 50 0.94 1.0 47.00 -25.0 10 AWG THWN-2 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC TEMPERATURE COEFFICIENT OF Voc # OF MODULES HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+(400W)37.13 10.77 45.30 11.14 -0.27%/°C 19 MODULE DIMENSION 74.0" L x 41.1" W x 1.26"D INVERTER SPECIFICATIONS MANUFACTURER / MODEL # QUANTITY NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT SOLAREDGE SE6000H-US RGM W/ INTERNAL CT'S 01 240 VAC 25.0A SYSTEM SIZE:- 19 X 400W = 7.600 KWDC 19 X 371.5W X 0.99 = 6.988 CEC KWAC MSP UPGRADE: YES EXISTING MSP INFORMATION (E) 100A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER (N) SURGE-PROTECTIVE DEVICE (AS PER 2020 NEC 230.67(A) & (D)) 20A-50A SURGE-PROTECTIVE DEVICE BREAKER NOTE: PV BREAKER CALCULATION (25.0X1.25X01=31.25~40A) (N) SURGE-PROTECTIVE DEVICE 301 N Bewley St 09/14/23 SHEET NAME SHEET NUMBER PV-5 PROJECT NAME MI C H A E L C O R D A Y 30 1 N B E W L E Y S T , SA N T A A N A , C A , 9 2 7 0 3 U S A AP N # 1 9 8 2 4 2 3 6 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" DEL MAR, CA 92014, USA REVDATE DESCRIPTION VERSION UR03/16/2023 INITIAL RELEASE DESIGN SUPPORT DAY OF INSTALL: CHAT.POWUR.COM A04/19/2023REVISION 09/08/2023REVISION B WARNING LABELS & PLACARD LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(D)(2) LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER CEC 705.12(B)(3)(3) & CEC 690.59) NOTES AND SPECIFICATIONS: x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. x LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. x DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: CEC 706.15 (C)(4) & CEC 690.13(B) 25.0 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: MAIN SERVICE PANEL PER CODE(S): 2022 CEC 690.56(C) 2022 CFC 1204.5.1 ! 4" 3" PHOTOVOLTAIC AC DISCONNECT WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.13(B)) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: CEC 690.13(B)) THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: CEC 705.12(B)(3)(3) LABEL LOCATION: MSP (PER CODE: CEC 705.12(B)(3) & CEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING CEC 705.12 (B)(3)(2) ! ! ! LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2) WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! LABEL LOCATION: INVERTER PER CODE: CEC 690.31(E) CAUTION ! MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER- . POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . A V V A 20.00 380 480 30 LABEL LOCATION: DC DISCONNECT, INVERTER# (PER CODE: CEC 690.53) 301 N BEWLEY ST (N) PV ARRAY (E) UTILITY METER (N) 125A MAIN SERVICE PANEL WITH (N) 100A MAIN BREAKER (N) INVERTER B 301 N Bewley St 09/14/23