HomeMy WebLinkAbout1312 E Warner Ave - PlanVICINITY MAP AERIAL MAP (N) AUGMENTATION UNITS AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT ATS AUTOMATIC TRANSFER SWITCH BESS BATTERY ENERGY STORAGE SYSTEM BLDG BUILDING CLR CLEAR CONC CONCRETE COMM COMMUNICATION DC DIRECT CURRENT DIA DIAMETER DIST DISTANCE EQ EQUAL EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EA. EACH EMT ELECTRICAL METALLIC TUBING EV ELECTRIC VEHICLE GAB GRADED AGGREGATE BASE GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HVAC HEATING, VENTILATION, & AIR CONDITIONING I CURRENT IMP CURRENT AT MAX POWER INV INVERTER ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT-HOUR LV LOW-VOLTAGE MAX MAXIMUM MIN MINIMUM MV MEDIUM-VOLTAGE (N) NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NRTL NATIONALLY-RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE OC ON CENTER PCC POINT OF COMMON COUPLING PL PROPERTY LINES PLC POWER LINE COMMUNICATION POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC PP POWERPACK PVC POLYVINYL CHLORIDE RSD RAPID SHUTDOWN SCH SCHEDULE SQ. IN. SQUARE INCHES SS STAINLESS STEEL SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS TYP TYPICAL UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY VIF VERIFY IN FIELD W WATT ABBREVIATIONS SHEET INDEX APPLICABLE CODES 2022 CEC 2022 CBC/ASCE 7-16 2022 CFC STRUCTURAL ENGINEER OF RECORD: KIRILL VORONOV TESLA, INC. 721 FERNCREST RD TRINIDAD, CA 95570 P:(818) 943-7621 KVORONOV@TESLA.COM PROJECT SCOPE INSTALLATION OF BATTERY ENERGY STORAGE SYSTEM AUGMENTATION UNITS AS PART OF PLANNED SERVICE ACTIONS. WORK TO INCLUDE · ANCHORING OF AUGMENTATION UNITS ON EXISTING FOUNDATIONS ·ANCHORING OF POWER SUPPLY CABINETS ON EXISTING FOUNDATIONS ·CONNECTING LOW VOLTAGE ELECTRICAL BETWEEN POWER SUPPLY CABINETS, AUGMENTATION UNITS, AND EXISTING EQUIPMENT 1. WIND DESIGN - DESIGN WIND SPEED = 95 MPH (ULTIMATE) - RISK CATEGORY = II - WIND EXPOSURE = C 2. SEISMIC DESIGN - RISK CATEGORY = II - SEISMIC IMPORTANCE FACTOR = 1.0 - S_S = 1.272 g, S_1 = 0.455 g - SITE CLASS = E - S_DS = 1.018 g, S_D1 = 0.696 g - SEISMIC DESIGN CATEGORY = D - BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT - R = 2.5 / a_p = 1.0 PROJECT TEAM SYSTEM SUMMARY PROJECT LOCATION BATTERY ENERGY STORAGE SYSTEM (BESS) AUGMENTATION AUGMENTATION UNIT RATINGS ENERGY RATING 480 kWh BATTERY BATTERY AUGMENTATION UNIT TYPE PP3 PART # 1930712-00-A QTY 8 DISCHARGE 4 HR SHEET # SHEET TITLE G-001 COVER PAGE G-002 NOTES E-101 ELECTRICAL SITE PLAN E-300 SINGLE LINE DIAGRAM E-301 SINGLE LINE DIAGRAM E-501 ELECTRICAL DETAILS E-601 CUTSHEETS S-501 STRUCTURAL DETAILS DESIGN CRITERIA N S EW N S EW ELECTRICAL ENGINEER OF RECORD: LEO WU TESLA, INC. 3500 DEER CREEK PALO ALTO, CA 94304 P:(415)830-0425 M:(415)830-0425 LEOWU@TESLA.COM CALPINE - PHASE 2 MEGAPACK SYSTEM AUGMENTATION APN: 016-150-52 PROJECT DESIGNER: ANTHONY FERREIRA TESLA, INC. 3500 DEER CREEK PALO ALTO, CA 94304 AFERREIRA@TESLA.COM PROJECT MANAGER: JUN LEE TESLA, INC. 3500 DEER CREEK ROAD PALO ALTO, CA 94304 LEEJU@TESLA.COM 1"12" 0 PROPRIETARY AND CONFIDENTIAL AB C D E F G H 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A C H A N G E S T O E L E C T R I C A L S H E E T S CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 COVER PAGE G-001 REV: A IFP VQUIRINDONGOPLOT DATE: 2/16/2024 9:22 AM JB-9275066 CA L P I N E - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N A Digitally signed by Leo Wu DN: C=US, E=leowu@tesla.com, O=Tesla Inc., OU=Energy Products Engineering, CN=Leo Wu Location: Palo Alto Reason: I am approving this document. Contact Info: 4158300425 Date: 2024.02.16 15:17:19-08'00' Bldg# 101117461 Elec# 20181504 APPROVALS: PLNG - HJacinto BLDG - GHuang ELEC - MSmith 1312 E Warner Ave - 101117461 & 201815044/29/2024 CONCRETE NOTES 1.ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE ACI. 2.CONCRETE SHALL BE NORMAL WEIGHT AND SHALL HAVE 2,500 PSI STRENGTH AT 28 DAYS. 3.REINFORCED CONCRETE IN THE FOUNDATION SHALL BE OF NATURAL AGGREGATE CONFORMING TO ASTM C-33. 4.TYPE I/II CEMENT TO MEET ASTM C150. 5.REINFORCING STEEL - ASTM A615 WITH THE FOLLOWING STRENGTHS: SIZE STRENGTH: #4 AND SMALLER GRADE 60 (fy = 60000 PSI) #5 AND LARGER GRADE 60 (fy = 60000 PSI) 6.FABRICATE AND PLACE REINFORCEMENT IN ACCORDANCE WITH ACI PUBLICATION SP-66, ACI DETAILING MANUAL - LATEST EDITION. 7.PLACE CONCRETE IN COMPLIANCE WITH ACI 304. ALL CONCRETE SHALL BE MECHANICALLY VIBRATED. 8.CONFORM TO ASTM C-94 FOR CONCRETE MIXING OPERATIONS. 9.CONCRETE COVER FOR REINFORCEMENT FOR NON-PRESTRESSED, CAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: CONDITION COVER CAST AGAINST EARTH 3" EXPOSED TO WEATHER #5 AND SMALLER 1-1/2" #6 AND LARGER 2" SLAB-ON-GRADE 2" 10.EMBEDS -ALL ITEMS TO BE CAST INTO CONCRETE SUCH AS REINFORCING DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY AND ACCURATELY POSITIONED INTO THE FORMS PRIOR TO PLACING THE CONCRETE. 11.ALL CONCRETE EXPOSED TO THE WEATHER TO BE AIR ENTRAINED AND SHALL CONFORM TO ASTM C-260. 12.PROVIDE CONTINUOUS REINFORCING BARS UNLESS WHERE SPLICES ARE SPECIFICALLY SHOWN ON THE DRAWINGS. 13.CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING CHLORIDE SALTS SHALL NOT BE ADDED TO THE CONCRETE. AUGMENTATION UNIT ANCHORAGE NTS 4.5" MIN EDGE DISTANCE CONCRETE PAD AALTERNATE AUGMENTATION UNIT ANCHORAGE NTS CONCRETE PAD 3 8" THICK A36 PAINTED STEEL PLATE TOP VIEW (2) 5 8" DIA. A325 GALV. THRU BOLTS B CONCRETE PAD 1" TYP.1" TYP. NOTCH CONCRETE TO ACCOMMODATE BOLT HEAD 4.5" MIN ANCHOR EDGE DISTANCE 5/8" DIA SS HILTI KWIK BOLT TZ2 INSTALLED PER ESR-4266 W/ 4.5" NOMINAL EMBED OR 5/8" DIA. SS HILTI HIT-HY 200 V3 ADHESIVE ANCHOR INSTALLED PER ESR-4868 W/4.5" EMBED FILL W/ NON-SHRINK GROUT EA. EA. 1" TYP. 5.5" MAX 6" SIDE OF (N) AUGMENTATION UNIT EDGE OF CONCRETE PAD WHERE OCCURS SIDE OF (E) MEGAPACK 6" MIN 5/8" DIA SS HILTI KWIK BOLT TZ2 INSTALLED PER ESR-4266 W/ 4.5" NOMINAL EMBED OR 5/8" DIA. SS HILTI HIT-HY 200 V3 ADHESIVE ANCHOR INSTALLED PER ESR-4868 W/4.5" EMBED POWER CABINET ANCHORAGE NTSC 2.5" MIN EDGE DISTANCE CONCRETE PAD 1/2" DIA SS HILTI KWIK BOLT TZ2 INSTALLED PER ESR-4266 W/ 3" NOMINAL EMBED OR 1/2" DIA. SS HILTI HIT-HY 200 V3 ADHESIVE ANCHOR INSTALLED PER ESR-4868 W/3" EMBED (E) MEGAPACK 2, TYP.(MIN. 8, MAX. 28) 51 2" 4" 4" 3'-1" 4" 4" 6" 1'-7"3' 2' (N) POWER SUPPLY CABINET (N) AUGMENTATION UNIT, TYP. (N) WORKING CLEARANCE (N) WORKING CLEARANCE10" 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 STRUCTURAL DETAILS S-501 REV: 0 PERMIT VQUIRINDONGOPLOT DATE: 10/27/2023 9:37 AM JB-######   CA L P I N E - - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N N S EWENLARGED STRUCTURAL SITE 1/2" = 1'-0" 0 1/2 1/4 A & B - C - POWER SUPPLY CABINET NTS 1312 E Warner Ave - 101117461 & 201815044/29/2024 (E) MEGAPACK 2 TYP. OF 28 (N) AUGMENTATION UNIT, TYP. of 8 (N) POWER SUPPLY CABINET, TYP. 1 PER AUGMENTATION UNIT (E) TRANSFORMER, TYP. FUTURE AUGMENTATION UNIT, TYP. FUTURE AUGMENTATION SCOPE ON SEPARATE PERMIT AREAS OF INTEREST (N) AUGMENTATION UNIT (E) LIGHT POLE (E) UTILITY POLE PROPERTY LINE SITE LEGEND (E) FENCE (E) MEGAPACK ENCLOSURE FUTURE AUGMENTATION UNIT 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 ELECTRICAL SITE PLAN E-101 REV: A IFP VQUIRINDONGOPLOT DATE: 2/16/2024 9:23 AM JB-9275066   CA L P I N E - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N NS E W ELECTRICAL SITE PLAN 1" = 20'0 20'40' A 1312 E Warner Ave - 101117461 & 201815044/29/2024 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 SINGLE LINE DIAGRAM E-300 REV: A IFP VQUIRINDONGOPLOT DATE: 2/16/2024 9:23 AM JB-9275066   CA L P I N E - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N REFERENCE ONLY SEE PREVIOUS PERMIT A 1312 E Warner Ave - 101117461 & 201815044/29/2024 STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-3.1B' 'AC-3.1A''AC-3.1C' TESLA MEGAPACK 3.1B TESLA MEGAPACK 3.1A TESLA MEGAPACK 3.1D TESLA MEGAPACK 3.1C 'AC-3.1D' 'MV-3.2' 8" PVC WITH: (3) 1/C 1000MCM AL MV-105, 15KV 100% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) BESS TRANSFORMER 3.1 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.43%, X/R=9.20 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 3.2 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.31%, X/R=9.10 NOTES: 1. XOB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XOA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 3.3 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.43%, X/R=9.13 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 3.4 1.800 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.62%, X/R=8.88 NOTES: 1. Xo TO BE BONDED TO GROUND PAD IN LV CABINET. STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-3.2B' 'AC-3.2A''AC-3.2C' TESLA MEGAPACK 3.2B TESLA MEGAPACK 3.2A TESLA MEGAPACK 3.2D TESLA MEGAPACK 3.2C 'AC-3.2D' 'MV-3.2' 8" PVC WITH: (3) 1/C 1000MCM AL MV-105, 15KV 100% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC 750MCM CU GEC INTEGRATED FUSE, SERVICEABLE ONLY BY TESLA FACTORY INSTALLED DC CONNECTION TORQUE AC TERMINALS PER INSTALLATION MANUAL 1600A 3P LSIG BATTERY / CONVERTER MODULE (TYP) FACTORY INSTALLED INTEGRATED THERMAL & OVER CURRENT PROTECTION 480V INVERTER AC OUTPUT UNGROUNDED DC SYSTEM INTEGRATED GFCI CTRL 1" EMT WITH: CU CAT 6A F/UTP SHIELDED CABLE TO FNE ENCLOSURE WIREWAY WITH: 1#750MCM EGC CU-XHHW2-TC & 4 SETS OF: 3#750MCM AL-XHHW2-TC G TESLA MEGAPACK 4.1A 4-HOUR RATED 480V, 1,082.5A OUTPUT 761.9 KW, 900.0KVA 3,047.6 kWh CAPACITY AC & DC GFCI 85kAIC NEMA 3R NOTE: CONTRACTOR IS RESPONSIBLE FOR INSTALLING TESLA MEGAPACK PER INSTALLATION MANUAL TYPICAL TESLA MEGAPACK STATIC SHIELD CLF EXP GXoBGXoA 'MV-3.1' 2 SETS OF 5" PVC EACH WITH: (3) 1/C 500MCM AL MV-105, 15KV 133% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) TO T1 SWITCHGEAR BREAKER 52-F3 SEE E300 G 2#4/0 CU GEC 'AC-4.1B' 'AC-4.1A''AC-4.1C' TESLA MEGAPACK 4.1B TESLA MEGAPACK 4.1D TESLA MEGAPACK 4.1C 'AC-4.1D' PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC 'MV-3.1' 2 SETS OF 5" PVC EACH WITH: (3) 1/C 500MCM AL MV-105, 15KV 133% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) TO T1 SWITCHGEAR BREAKER 52-F3 SEE E300 STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-3.3B' 'AC-3.3A''AC-3.3C' TESLA MEGAPACK 3.2B TESLA MEGAPACK 3.3A TESLA MEGAPACK 3.3D TESLA MEGAPACK 3.3C 'AC-3.3D' 'MV-3.3' 8" PVC WITH: (3) 1/C 1000MCM AL MV-105, 15KV 100% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC STATIC SHIELD CLF EXP GXo G 2#4/0 CU GEC 'AC-3.4B' 'AC-3.4A''AC-3.4C' TESLA MEGAPACK 3.4B TESLA MEGAPACK 3.4A TESLA MEGAPACK 3.4D TESLA MEGAPACK 3.4C 'AC-3.4D' 750MCM CU GEC (3) SAs 10kV 8.4MCOV BESS TRANSFORMER 4.1 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.09%, X/R=8.49 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 4.2 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.38%, X/R=9.0 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-4.2B' 'AC-4.2A''AC-4.2C' TESLA MEGAPACK 4.2B TESLA MEGAPACK 4.2A TESLA MEGAPACK 4.2D TESLA MEGAPACK 4.2C 'AC-4.2D' PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC 750MCM CU GEC BESS TRANSFORMER 4.3 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.36%, X/R=9.18 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 4.4 1.800 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.65%, X/R=8.88 NOTES: 1. Xo TO BE BONDED TO GROUND PAD IN LV CABINET. STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-4.3B' 'AC-4.3A''AC-4.3C' TESLA MEGAPACK 4.2B TESLA MEGAPACK 4.3A TESLA MEGAPACK 4.3D TESLA MEGAPACK 4.3C 'AC-4.3D' PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC STATIC SHIELD CLF EXP GXo G 2#4/0 CU GEC 'AC-4.4B' 'AC-4.4A''AC-4.4C' TESLA MEGAPACK 4.4B TESLA MEGAPACK 4.4A TESLA MEGAPACK 4.4D TESLA MEGAPACK 4.4C 'AC-4.4D' 750MCM CU GEC (3) SAs 10kV 8.4MCOV 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 SINGLE LINE DIAGRAM E-301 REV: A IFP VQUIRINDONGOPLOT DATE: 2/16/2024 9:23 AM JB-9275066   CA L P I N E - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N REFERENCE ONLY SEE PREVIOUS PERMIT A 1312 E Warner Ave - 101117461 & 201815044/29/2024 (E) MEGAPACK 2 TO XFMR 480/277V 3Φ 4W FUTURE AUGMENTATION CONNECTIONS (E) 1600A/3P (N) POWERPACK 3 AUGMENTATION UNIT, TYP. EXISTING BATTERY MODULES 300 MCM CU, XHHW-2 (3) WIRE + GND A GROUNDING DIAGRAM G (N) POWERPACK 3 AUGMENTATION UNIT (N) EGC 4/0 AWG CU. G (E) MEGAPACK 2 TO TRANSFORMER (E) GROUNDED CONDUCTOR AND CONNECTIONS LEGEND IRREVERSIBLE SPLICE OR CRIMP PER NEC 250.64(C) NEC 250.52(A)-COMPLIANT GROUNDING ELECTRODE PRIMARY OR SECONDARY COMMON TERMINAL, AS APPLICABLE G TERMINAL ON NEUTRAL OR GROUND BUSBAR N O NEUTRAL BUSBAR GROUND BUSBAR E701.118 DC CONDUIT AND JUNCTION BOXES LABEL RB POWER SUPPLY CABINET WARNING LABEL NTSE NOTE: 1. MARKING PER ART 690.56 2. REFLECTIVE, WATER RESISTANT MATERIAL 3. RED BACKGROUND 4. WHITE LETTERING, ALL CAPITAL LETTERS, ARIAL NON-BOLD FONT 5. TEXT HEIGHT: 3/8" MIN. CAUTION: SHOCK HAZARD 6" 3 4" B TYP. AUGMENTED MEGAPACK TESLA SUPPLIED KEPS NUT WITH INTEGRATED SPRING WASHER. TORQUE TO MFR SPECIFICATIONS & MARK WITH PAINT PEN AFTER TORQUING. UL-LISTED, 600V-RATED CRIMP. ONLY USE MFR-APPROVED CRIMP TOOL & DIE FOR CONNECTOR SIZE. APPLY ANTIOXIDANT COMPOUND BEFORE CRIMPING. BUSBAR OR TRANSFORMER SPADE TERMINATIONS TO BE COMPRESSION LUGS ONLY. BUSBAR WITH INTEGRATED STUD E501.101 COMPRESSION LUG TERMINATION DETAIL RA COMPRESSION LUG TERMINATION DETAIL NTSC QTY (1) - 4 HR RATED 480V 480 kWh 85kAIC NEMA 3R (N) POWERPACK 3 POWER SUPPLY CABINET, TYP. TO PP3 DC LOADS A A 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 ELECTRICAL DETAILS E-501 REV: A IFP VQUIRINDONGOPLOT DATE: 2/16/2024 9:23 AM JB-9275066   CA L P I N E - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N SHEET NOTES: 1.NO MORE THAN 8 AUGMENTATION UNITS TO BE INSTALLED. 2.NO MORE THAN ONE AUGMENTATION UNIT PER MEGAPACK. 3.EXACT LOCATION OF EACH AUGMENTATION UNIT TO BE DETERMINED AT TIME OF INSTALLATION. 1312 E Warner Ave - 101117461 & 201815044/29/2024 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 CUTSHEETS E-601 REV: 0 PERMIT VQUIRINDONGOPLOT DATE: 10/27/2023 9:36 AM JB-######   CA L P I N E - - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N 1312 E Warner Ave - 101117461 & 201815044/29/2024 ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM TESLA OF ANY DISCREPANCIES. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE SUBCONTRACTORS SOLE EXPENSE. SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TESLA FOR APPROVAL BEFORE MAKING ANY CHANGES. DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM TESLA PLACES LIABILITY ON THE SUBCONTRACTOR. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE DRAWINGS. NEW PAVEMENT INSTALLED AS PART OF THIS PROJECT SHALL MATCH EXISTING PAVEMENT SECTION. ASPHALT AND GAB DEPTHS SHALL BE MAINTAINED. GENERAL NOTES GENERAL NOTES 1.ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. 2.ALL WIRING SHALL BE MANAGED IN A PROFESSIONAL, WORKMAN-LIKE MANNER AND MUST BE SUPPORTED, SECURED, AND PROTECTED TO PREVENT DAMAGE. 3.AC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER ART 210.5 OR 215.12. UNLESS OTHERWISE REQUIRED BY ART 210.5(1) OR AHJ, COLOR-CODING OF POWER CONDUCTORS SHALL BE AS FOLLOWS: CONDUCTOR 277/480V 120/208V PHASE A BROWN BLACK PHASE B ORANGE RED PHASE C YELLOW BLUE NEUTRAL GRAY WHITE 4.DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED PER ART 210.5 OR 215.12: CONDUCTOR STD COLOR ALT COLOR DC+RED RED-STRIPED DC-BLACK BLACK-STRIPED 5.TERMINATIONS OF AC, DC, AND COMMUNICATIONS CONDUCTORS SHALL BE PROFESSIONALLY AND LEGIBLY LABELED WITH CIRCUIT SCHEDULE IDENTIFIER, CONDUCTOR SIZE (AS APPLICABLE) AND TERMINATION TORQUE. 6.ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, ENGINEERING APPROVAL SHALL BE OBTAINED PRIOR TO EQUIPMENT MODIFICATION, AND THE EQUIPMENT SHALL BE RELISTED BY A SUITABLE NRTL. 7.UNDERGROUND CONDUCTORS & CABLES TO BE INSTALLED IN CONDUIT UON. 8.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NRTL LISTING. 9.REFER TO MANUFACTURER'S CURRENT PLANNING AND INSTALLATION MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. 10.ALL CONDUCTOR TERMINATIONS ON BUSSING OR TRANSFORMER SPADES SHALL BE MADE WITH HIGH-PRESS CRIMP LUGS UON. 11.ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY INSTALLED WITH BEST PRACTICES INCLUDING BUT NOT LIMITED TO: ·USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE ·ALLOWANCE FOR MOVEMENT DUE TO THERMAL EXPANSION/CONTRACTION ·PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION COMPOUND ·USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO REQUIRED SETTINGS 12.DUCT SEAL COMPOUND SHALL BE APPLIED WHEREVER CONDUITS TRANSITION INDOOR/OUTDOOR OR UNDERGROUND/ABOVEGROUND. REFER TO EQUIPMENT NOTES FOR ADDITIONAL DUCT SEAL REQUIREMENTS. 13.BELL ENDS SHALL BE INSTALLED WHEREVER CONDUIT ENTERS EQUIPMENT FROM UNDERGROUND AND WHEREVER POTENTIAL FOR DAMAGE TO CONDUCTORS IS PRESENT AT ANY POINT. BELL ENDS SHALL NOT PREVENT THE USE OF GROUNDING FITTINGS OR COUPLERS WHEN REQUIRED. 14.ALL STUB-UPS WITHIN FLOOR-MOUNTED EQUIPMENT SHALL BE 3-5" ABOVE FINISHED GRADE. 15.ALL CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE SHALL BE RIGID GALVANIZED STEEL. 16.GROUND LUGS SHALL BE RATED FOR THEIR ENVIRONMENT AND CONDITION OF USE. ELECTRICAL NOTES 1.LOAD SIDE INTERCONNECTIONS SHALL COMPLY WITH NEC ART 705.12(B). 2.WHERE THE INTERCONNECTION POINT OCCURS ON FEEDERS, THE FEEDER AMPACITY SHALL NOT BE LESS THAN THE SUM OF ALL THE SOURCES CONNECTED TO THE FEEDER UNLESS THE FEEDER IS PROTECTED ON THE LOAD SIDE OF THE INTERCONNECTION POINT WITH OVERCURRENT PROTECTION NO GREATER THAN THE AMPACITY OF THE FEEDER. 3.TAP CONNECTIONS SHALL COMPLY WITH ART 240.21(B). 4.WHERE THE SUM OF ALL THE OVERCURRENT DEVICE RATINGS ON THE PANEL LOAD SIDE OF A MAIN OVERCURRENT PROTECTION DEVICE ARE LESS THAN THE RATING OF THE PANEL, PERMANENT WARNING LABELS WITH THE FOLLOWING WORDING MUST BE APPLIED: WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. 5.WHERE THE SUM OF THE UTILITY OVERCURRENT DEVICE AND 125% OF INVERTER OUTPUT CIRCUIT CURRENT DOES NOT EXCEED 120% OF THE RATING OF THE BUSBAR, THE INTERCONNECTION POINT MUST BE ON THE OPPOSITE END OF THE BUSBAR FROM THE INCOMING UTILITY SOURCE AND A PERMANENT WARNING LABEL MUST BE APPLIED TO THE INTERCONNECTION POINT. 6.LOAD SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE THE NRTL LISTING OF THE EQUIPMENT. WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, EQUIPMENT MUST BE RELISTED BY AN APPROVED NRTL SUITABLE FOR THE EQUIPMENT. UTILITY-INTERACTIVE INVERTER LOAD-SIDE INTERCONNECTION NOTES 1.CAT5E/6 SHIELDED CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS OF INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL DISTANCE OF 328 FEET (100M) PER CHAIN. 2.RS485 CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS OF INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL DISTANCE OF 3280 FEET (1000M) PER CHAIN. 3.SWITCHES, METERS, POWERPACK CONTROLLERS, CT'S, AND PT'S, AND CONDUCTORS MARKED "PRE-INSTALLED" IN THE LINE DIAGRAM WILL ARRIVE TO SITE PRE-INSTALLED WITHIN THE SWITCHBOARD, AND WILL NOT REQUIRE ANY FIELD INSTALLATION OR MODIFICATION OF ANY KIND. 4.FIBER OPTIC CABLE RUNS SHALL UTILIZE OUTDOOR DUCT OR DIRECT BURIAL RATED SINGLE MODE (OS2) CABLES COMPATIBLE WITH COMMUNICATION WAVELENGTHS BETWEEN 1310 - 1550 NM. COMMUNICATION NOTES GENERAL NOTES 1.REFER TO THE SPECIFIC PRODUCT MANUFACTURER'S INSTALLATION AND OPERATION MANUAL FOR MORE INFORMATION. 2.BATTERY ENERGY STORAGE SYSTEM (BESS) SHALL BE SERVICED ONLY BY MANUFACTURER-CERTIFIED TECHNICIANS. 3.SECONDARY CONTAINMENT IS NOT REQUIRED FOR THE BATTERY BESS. 4.BATTERY PACK DC CONNECTIONS TO BESS INVERTER SHALL ONLY BE MADE WITH MANUFACTURER-PROVIDED CONDUCTOR HARNESSES. 5.BESS DISCONNECTING MEANS SHALL BE LABELED PER ART 706.7(D). BESS AND INTERCONNECTION SHALL BE LABELED PER ART 706.11. BESS NOTES SITE LEGEND (E) ACCESSIBLE PARKING SPACE (E) LIGHT POLE FH (E) FIRE HYDRANT G E SS SD T TV ? W GV HB IV WV WR T CO (E) STORM MANHOLE (E) GUY WIRE - ELECTRIC (E) HOSE BIB (E) GAS VALVE (E) IRRIGATION VALVE (E) WATER VALVE (E) SPRINKLER HEAD (E) WATER RISER (E) SPRINKLER HEAD (E) CLEANOUT (E) ELECTRIC MANHOLE (E) GAS MANHOLE (E) SANITARY SEWER MANHOLE (E) TELEPHONE MANHOLE (E) TELEVISION MANHOLE (E) UNKNOWN MANHOLE (E) POTABLE WATER MANHOLE (E) UTILITY POLE - ELECTRIC (E) UTILITY POLE - TELEPHONE (E) GUY WIRE (E) TREE UE (E) UNDERGROUND ELECTRIC LINE ST (E) UNDERGROUND STORM DRAIN LINE WL (E) UNDERGROUND WATER LINE UG (E) UNDERGROUND GAS LINE OE (E) OVERHEAD ELECTRIC LINE UT (E) UNDERGROUND TELEPHONE LINE SS (E) UNDERGROUND SANITARY SEWER LINE (E) VENT PIPE (E) ROOF ACCESS HATCH (E) EXHAUST FAN (E) SKYLIGHT (E) HVAC UNIT (E) OPERABLE SKYLIGHT (E) CONDENSATION CONDUIT LINEWL GAS ELE (E) GAS CONDUIT LINE (E) ELECTRICAL CONDUIT LINE (E) UTILITY POLE GENERAL NOTES 1.TESLA, AT THE TIME OF INSTALLATION, SHALL CONFIGURE THE AUGMENTED MEGAPACKS SUCH THAT: 1.1.THE INTERNAL MEGAPACK CONTROLLER ADJUSTS THE MAXIMUM ALLOWABLE CURRENT OF THE INVERTERS WITH FIRMWARE SO THAT THE AUGMENTED MEGAPACK'S CURRENT CAPABILITY AND THUS KVA RATING ARE MAINTAINED, REGARDLESS OF THE NUMBER OF INVERTERS. 1.2.THE CURRENT IS LIMITED AT THE INVERTER LEVEL, THE SHORT-CIRCUIT CONTRIBUTION OF THE AUGMENTED MEGAPACK REMAINS UNCHANGED. BESS AUGMENTATION NOTES 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 CA L P I N E I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 NOTES G-002 REV: 0 PERMIT VQUIRINDONGOPLOT DATE: 10/27/2023 9:36 AM JB-######   CA L P I N E - - P H A S E 2 ME G A P A C K S Y S T E M A U G M E N T A T I O N 1312 E Warner Ave - 101117461 & 201815044/29/2024 EQUIPMENT ANCHORAGE CALCULATIONS PROJECT: Calpine Phase 2, Megapack System Augmentation 1312 E Warner Ave Santa Ana CA REPORT PREPARED FOR: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 PROJECT DESIGNED BY: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 1 1312 E Warner Ave - 101117461 & 201815044/29/2024 1. Lateral Loads Calculation for Equipment (2022 CBC) 1.1 Earthquake Load Latitude =36.2538 Longitude =-120.2394 Soil Site Class =D Seismic Use Group =II From Spectrum Data:(from output of Seismic Design Parameters) 1.272 g SMS =1.5264 g SDS =2/3 SMS =1.018 g 0.455 g SM1 =1.045 g SD1 =2/3 SM1 =0.696 g Seismic Design Category =D ρ =1.0 (ASCE 7, 12.3.4.1) Seismic Design Force : 2.5 ap 1.0 (ASCE 7, Table 13.6-1) p 1.0 z/h =0.0 CMA 11,000 lbs =1,791.0 lbs =17,909.8 lbs =3358.1 lbs Therefore 3,358 lbs Power Supply Cabinet 364 lbs =59.3 lbs =592.7 lbs =111.1 lbs Therefore 111 lbs 2 1312 E Warner Ave - 101117461 & 201815044/29/2024 1.2 Wind Loads on Equipment (2022 CBC) Basic Wind Speed =95 mph Exposure =C Mean Roof Height (h) =8.4 ft <60 ft Wind Loads on Other Structures CMA 5.9 ft D =3.7 ft H =8.4 ft Eff. Wind Area =49.4 ft2 30.8 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16, Fig. 29.4-1) =1.32 α 15.00 ft 900 ft α =9.5 0.85 =1.0 0.9 Threfore, 17.7 psf Threfore, 19.8 psf Wind Force W =980 lbs 3 1312 E Warner Ave - 101117461 & 201815044/29/2024 Power Supply Cabinet W =2.0 ft D =1.6 ft 5.9 ft Eff. Wind Area =11.8 ft2 9.4 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16, Fig. 29.4-1) =1.35 α 15.00 ft 900 ft α =9.5 0.85 1.0 0.9 Threfore, 17.7 psf Threfore, 20.2 psf 239 lbs 4 1312 E Warner Ave - 101117461 & 201815044/29/2024 1.3 Anchor Bolt Design CMA 2022 CBC Wind=980 lbs SDC=D EQ*Ω=6,716 lbs Ω=2 Load combination used for the design: 0.696 DL +1.0 EQ DS 1 V =6,716 lbs 1 V x 0.3=2,015 lbs (orthogonal direction) c 8.4 ft.COG =4.2 ft. c 3.8 ft.W c 4.4 ft. p 7,661 lbs OT OT 28,054 lb-ft =8,416 lb-ft R p c R p c 14,604 lb-ft =16,919 lb-ft M =OT R OT R =13,450 lb-ft =-8,502 lb-ft Anchor Bolts for CMA 4 T (Tension on Bolt) =(M / Dc) / 2 bolts T (Tension on Bolt) =(M / Wc) / 2 bolts =1,764 lbs.=0 lbs. V (Shear on Bolt) =V / 4 bolts V (Shear on Bolt) =V / 4 bolts =1,679 lbs.=504 lbs. V W p Hc 5 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 1 Kirill Voronov kvoronov@tesla.com 10/9/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 5/8 (4) hnom3 Item number: 2210279 KB-TZ2 5/8x6 SS304 Effective embedment depth: hef,act = 4.000 in., hnom = 4.500 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.625 in. Anchor plateR : lx x ly x t = 2.000 in. x 6.000 in. x 0.625 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] 6 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 2 Kirill Voronov kvoronov@tesla.com 10/9/2023 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 1,764; Vx = 1,679; Vy = 504; Mx = 0; My = 0; Mz = 0; yes 99 Tension 1 x y2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1,764 1,753 1,679 504 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 1,764 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,764 14,132 13 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**1,764 2,683 66 OK * highest loaded anchor **anchor group (anchors in tension) 7 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 3 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.16 114,604 Calculations Nsa [lb] 18,843 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 18,843 0.750 1.000 14,132 1,764 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 4.000 4.500 1.000 9.000 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 126.00 144.00 0.925 1.000 6,800 Results Ncb [lb]f concrete f seismic f nonductile f Ncb [lb]Nua [lb] 5,504 0.650 0.750 1.000 2,683 1,764 8 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 4 Kirill Voronov kvoronov@tesla.com 10/9/2023 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*1,753 8,034 22 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**1,753 7,705 23 OK Concrete edge failure in direction x+**1,753 2,680 66 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.16 114,604 1.000 Calculations Vsa,eq [lb] 12,360 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 12,360 0.650 1.000 8,034 1,753 9 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 5 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 2 4.000 4.500 1.000 cac [in.]kc l a f' c [psi] 9.000 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 126.00 144.00 0.925 1.000 6,800 Results Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] 11,007 0.700 1.000 1.000 7,705 1,753 10 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 6 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.3 Concrete edge failure in direction x+ Vcb = (AVc AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) f Vcb ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] 4.500 12.000 1.000 12.000 4.000 l a da [in.]f' c [psi]y parallel,V 1.000 0.625 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] 91.13 91.13 1.000 1.000 3,829 Results Vcb [lb]f concrete f seismic f nonductile f Vcb [lb]Vua [lb] 3,829 0.700 1.000 1.000 2,680 1,753 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.657 0.654 5/3 99 OK bNV = bz N + bz V <= 1 11 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 7 Kirill Voronov kvoronov@tesla.com 10/9/2023 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 12 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 1 Kirill Voronov kvoronov@tesla.com 10/9/2023 Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200 V3 + HAS-R 304/316 SS 5/8 Item number: 2045007 HAS-R 316 SS 5/8"x7 5/8" (element) / 2334276 HIT-HY 200-R V3 (adhesive) Effective embedment depth: hef,act = 4.500 in. (hef,limit = - in.) Material: ASTM F 593 Evaluation Service Report: ESR-4868 Issued I Valid: 11/1/2022 | 11/1/2024 Proof: Design Method ACI 318-19 / Chem Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.625 in. Anchor plateR : lx x ly x t = 2.000 in. x 6.000 in. x 0.625 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in., Temp. short/long: 32/32 °F Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] 13 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 2 Kirill Voronov kvoronov@tesla.com 10/9/2023 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 1,764; Vx = 1,679; Vy = 504; Mx = 0; My = 0; Mz = 0; yes 90 Tension 1 x y2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1,764 1,753 1,679 504 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 1,764 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,764 14,690 13 OK Bond Strength**1,764 3,210 55 OK Sustained Tension Load Bond Strength*N/A N/A N/A N/A Concrete Breakout Failure**1,764 2,967 60 OK * highest loaded anchor **anchor group (anchors in tension) 14 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 3 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4868 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.23 100,000 Calculations Nsa [lb] 22,600 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 22,600 0.650 1.000 14,690 1,764 15 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 4 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.2 Bond Strength Na = (ANa ANa0)y ed,Na y cp,Na Nba ACI 318-19 Eq. (17.6.5.1a) f Na ³ Nua ACI 318-19 Table 17.5.2 ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b) ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a) cNa = 10 da √t uncr 1100 ACI 318-19 Eq. (17.6.5.1.2b) y ed,Na = 0.7 + 0.3 (ca,min cNa )£1.0 ACI 318-19 Eq. (17.6.5.4.1b) y cp,Na = MAX(ca,min cac , cNa cac )£1.0 ACI 318-19 Eq. (17.6.5.5.1b) Nba = l a · t k,c · aN,seis · p · da · hef ACI 318-19 Eq. (17.6.5.2.1) Variables t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]aoverhead t k,c [psi] 2,220 0.625 4.500 4.500 1.000 1,170 cac [in.]l a aN,seis 6.587 1.000 0.990 Calculations cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na 8.839 235.80 312.50 0.853 y cp,Na Nba [lb] 1.000 10,234 Results Na [lb]f bond f seismic f nonductile f Na [lb]Nua [lb] 6,585 0.650 0.750 1.000 3,210 1,764 16 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 5 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.3 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 4.500 4.500 1.000 6.587 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 151.87 182.25 0.900 1.000 8,114 Results Ncb [lb]f concrete f seismic f nonductile f Ncb [lb]Nua [lb] 6,086 0.650 0.750 1.000 2,967 1,764 17 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 6 Kirill Voronov kvoronov@tesla.com 10/9/2023 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*1,753 6,509 27 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength (Concrete Breakout Strength controls)** 1,753 8,520 21 OK Concrete edge failure in direction x+**1,753 2,744 64 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4868 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.23 100,000 0.800 Calculations Vsa,eq [lb] 10,848 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 10,848 0.600 1.000 6,509 1,753 18 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 7 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.2 Pryout Strength (Concrete Breakout Strength controls) Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 2 4.500 4.500 1.000 cac [in.]kc l a f' c [psi] 6.587 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 151.87 182.25 0.900 1.000 8,114 Results Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] 12,171 0.700 1.000 1.000 8,520 1,753 19 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 8 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.3 Concrete edge failure in direction x+ Vcb = (AVc AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) f Vcb ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] 4.500 12.000 1.000 12.000 4.500 l a da [in.]f' c [psi]y parallel,V 1.000 0.625 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] 91.13 91.13 1.000 1.000 3,920 Results Vcb [lb]f concrete f seismic f nonductile f Vcb [lb]Vua [lb] 3,920 0.700 1.000 1.000 2,744 1,753 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.595 0.639 5/3 90 OK bNV = bz N + bz V <= 1 20 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: Tesla | CMA Page: Specifier: E-Mail: Date: 9 Kirill Voronov kvoronov@tesla.com 10/9/2023 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the Evaluation Service Report for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 21 1312 E Warner Ave - 101117461 & 201815044/29/2024 Power Supply Cabinet 2022 CBC Wind=239 lbs SDC=D EQ*Ω=222 lbs Ω=2 Load combination used for the design: 0.900 DL +1.0 W DS 1 V =239 lbs 1 V x 0.3=72 lbs (orthogonal direction) c 5.9 ft.COG =3.0 ft. c 1.1 ft.W c 1.5 ft. p 328 lbs OT OT 707 lb-ft =212 lb-ft R p c R p c 177 lb-ft =246 lb-ft M =OT R OT R =529 lb-ft =-34 lb-ft Anchor Bolts for Power Supply Cabinet 4 T (Tension on Bolt) =(M / Dc) / 2 bolts T (Tension on Bolt) =(M / Wc) / 2 bolts =244 lbs.=0 lbs. V (Shear on Bolt) =V / 4 bolts V (Shear on Bolt) =V / 4 bolts =60 lbs.=18 lbs. V W p Hc 22 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 1 Kirill Voronov kvoronov@tesla.com 10/9/2023 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (2 1/2) hnom2 Item number: 2210260 KB-TZ2 1/2x3 3/4 SS304 Effective embedment depth: hef,act = 2.500 in., hnom = 3.000 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 2.000 in. x 2.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] 23 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 2 Kirill Voronov kvoronov@tesla.com 10/9/2023 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 244; Vx = 60; Vy = 18; Mx = 0; My = 0; Mz = 0; yes 23 Tension 1 x y2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 244 63 60 18 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 244 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*244 8,906 3 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**244 1,101 23 OK * highest loaded anchor **anchor group (anchors in tension) 24 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 3 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 120,404 Calculations Nsa [lb] 11,875 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 11,875 0.750 1.000 8,906 244 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 1.667 2.500 1.000 6.000 21 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 25.00 25.00 1.000 1.000 2,259 Results Ncb [lb]f concrete f seismic f nonductile f Ncb [lb]Nua [lb] 2,259 0.650 0.750 1.000 1,101 244 25 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 4 Kirill Voronov kvoronov@tesla.com 10/9/2023 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*63 5,426 2 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**63 3,163 2 OK Concrete edge failure in direction y+**63 567 12 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.10 120,404 1.000 Calculations Vsa,eq [lb] 8,348 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 8,348 0.650 1.000 5,426 63 26 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 5 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 2 1.667 2.500 1.000 cac [in.]kc l a f' c [psi] 6.000 21 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 25.00 25.00 1.000 1.000 2,259 Results Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] 4,518 0.700 1.000 1.000 3,163 63 27 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 6 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.3 Concrete edge failure in direction y+ Vcb = (AVc AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) f Vcb ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] 2.500 2.500 1.000 12.000 2.500 l a da [in.]f' c [psi]y parallel,V 1.000 0.500 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] 18.75 28.12 0.900 1.000 1,350 Results Vcb [lb]f concrete f seismic f nonductile f Vcb [lb]Vua [lb] 810 0.700 1.000 1.000 567 63 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.222 0.110 5/3 11 OK bNV = bz N + bz V <= 1 28 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 7 Kirill Voronov kvoronov@tesla.com 10/9/2023 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 29 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 1 Kirill Voronov kvoronov@tesla.com 10/9/2023 Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200 V3 + HAS-R 304/316 SS 1/2 Item number: 2045003 HAS-R 316 SS 1/2"x6 1/2" (element) / 2334276 HIT-HY 200-R V3 (adhesive) Effective embedment depth: hef,act = 3.000 in. (hef,limit = - in.) Material: ASTM F 593 Evaluation Service Report: ESR-4868 Issued I Valid: 11/1/2022 | 11/1/2024 Proof: Design Method ACI 318-19 / Chem Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 2.000 in. x 2.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in., Temp. short/long: 32/32 °F Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] 30 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 2 Kirill Voronov kvoronov@tesla.com 10/9/2023 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 244; Vx = 60; Vy = 18; Mx = 0; My = 0; Mz = 0; yes 94 Tension 1 x y2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 244 63 60 18 max. concrete compressive strain: - [‰] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 244 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*244 9,223 3 OK Bond Strength**244 260 94 OK Sustained Tension Load Bond Strength*N/A N/A N/A N/A Concrete Breakout Failure**244 892 28 OK * highest loaded anchor **anchor group (anchors in tension) 31 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 3 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4868 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.14 100,000 Calculations Nsa [lb] 14,190 Results Nsa [lb]f steel f nonductile f Nsa [lb]Nua [lb] 14,190 0.650 1.000 9,223 244 32 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 4 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.2 Bond Strength Na = (ANa ANa0)y ed,Na y cp,Na Nba ACI 318-19 Eq. (17.6.5.1a) f Na ³ Nua ACI 318-19 Table 17.5.2 ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b) ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a) cNa = 10 da √t uncr 1100 ACI 318-19 Eq. (17.6.5.1.2b) y ed,Na = 0.7 + 0.3 (ca,min cNa )£1.0 ACI 318-19 Eq. (17.6.5.4.1b) y cp,Na = MAX(ca,min cac , cNa cac )£1.0 ACI 318-19 Eq. (17.6.5.5.1b) Nba = l a · t k,c · aN,seis · p · da · hef ACI 318-19 Eq. (17.6.5.2.1) Variables t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]aoverhead t k,c [psi] 2,220 0.500 3.000 2.500 1.000 1,135 cac [in.]l a aN,seis 4.427 1.000 0.990 Calculations cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na 7.071 25.00 200.00 0.806 y cp,Na Nba [lb] 1.000 5,295 Results Na [lb]f bond f seismic f nonductile f Na [lb]Nua [lb] 534 0.650 0.750 1.000 260 244 33 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 5 Kirill Voronov kvoronov@tesla.com 10/9/2023 3.3 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 1.667 2.500 1.000 4.427 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 25.00 25.00 1.000 1.000 1,829 Results Ncb [lb]f concrete f seismic f nonductile f Ncb [lb]Nua [lb] 1,829 0.650 0.750 1.000 892 244 34 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 6 Kirill Voronov kvoronov@tesla.com 10/9/2023 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*63 4,087 2 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength (Bond Strength controls)**63 747 9 OK Concrete edge failure in direction y+**63 588 11 OK * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4868 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.14 100,000 0.800 Calculations Vsa,eq [lb] 6,812 Results Vsa,eq [lb]f steel f nonductile f Vsa,eq [lb]Vua [lb] 6,812 0.600 1.000 4,087 63 35 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 7 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.2 Pryout Strength (Bond Strength controls) Vcp =kcp[(ANa ANa0)y ed,Na y cp,Na Nba ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANa see ACI 318-19, Section 17.6.5.1, Fig. R 17.6.5.1(b) ANa0 = (2 cNa)2 ACI 318-19 Eq. (17.6.5.1.2a) cNa = 10 da √t uncr 1100 ACI 318-19 Eq. (17.6.5.1.2b) y ed,Na = 0.7 + 0.3 (ca,min cNa )£1.0 ACI 318-19 Eq. (17.6.5.4.1b) y cp,Na = MAX(ca,min cac , cNa cac )£1.0 ACI 318-19 Eq. (17.6.5.5.1b) Nba = l a · t k,c · aN,seis · p · da · hef ACI 318-19 Eq. (17.6.5.2.1) Variables kcp aoverhead t k,c,uncr [psi]da [in.]hef [in.]ca,min [in.]t k,c [psi] 2 1.000 2,220 0.500 3.000 2.500 1,135 cac [in.]l a aN,seis 4.427 1.000 0.990 Calculations cNa [in.]ANa [in.2]ANa0 [in.2]y ed,Na 7.071 25.00 200.00 0.806 y cp,Na Nba [lb] 1.000 5,295 Results Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] 1,067 0.700 1.000 1.000 747 63 36 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 8 Kirill Voronov kvoronov@tesla.com 10/9/2023 4.3 Concrete edge failure in direction y+ Vcb = (AVc AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) f Vcb ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b) AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] 2.500 2.500 1.000 12.000 3.000 l a da [in.]f' c [psi]y parallel,V 1.000 0.500 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] 18.75 28.12 0.900 1.000 1,400 Results Vcb [lb]f concrete f seismic f nonductile f Vcb [lb]Vua [lb] 840 0.700 1.000 1.000 588 63 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.938 0.107 1.000 88 OK bNV = (bN + bV) / 1.2 <= 1 37 1312 E Warner Ave - 101117461 & 201815044/29/2024 www.hilti.com Hilti PROFIS Engineering 3.0.88 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Company: Address: Phone I Fax: Design: Fastening point: Tesla | Power Supply Page: Specifier: E-Mail: Date: 9 Kirill Voronov kvoronov@tesla.com 10/9/2023 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the Evaluation Service Report for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 38 1312 E Warner Ave - 101117461 & 201815044/29/2024 Date: April 12, 2024 LETTER OF AUTHORIZATION Please be advised that Tesla Inc. California General Contractor License #949283 authorizes Jun Lee to act as an agent on our behalf in all matters related to obtaining any and all permits for Tesla Inc. General Contractor. This authorization letter is valid for six months from the date listed above. Our agent is designated and responsible for the following: • Delivering or providing our payment for fees and deposits, • Submitting drawings for review. • Retrieving jobsite copies of permit drawings. • And conducting any other activities required to fulfill the normal business of a general contractor We further understand and agree that we shall remain responsible for all permit conditions, permit provisions, fees, deposits, additional charges, and collections resulting from permit application processing, permit issuance and inspection of work. Sincerely, _______________________ Bradley Harbidge RME CSLB Lic. 949283 Tesla Inc, General Contractor 901 Page Ave. Attn: Licensing Fremont, CA 94538 Business Phone Number: (510) 602-3159 RME Phone Number (510) 508-6026 45500 Fremont Blvd., Fremont, CA 94538 P 520 249 3500 1312 E Warner Ave - 101117461 & 201815044/29/2024 Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304, U.S.A. February 12th, 2024 Subject: Tesla Megapack Augmentation To whom it may concern, Tesla energy products: Megapack 1 Battery Energy Storage System, BESS (Model #: 1462965*), Megapack 2 BESS (Model #: 1748844*), Megapack 2XL BESS (Model #: 1848844*) and Powerpack 3 BESS (Model #: 1930712*) have been evaluated to the UL 1741:2021, ANSI/CAN/UL 9540:2020 and ANSI/CAN/UL 9540A:2019 product safety standards. The power supply used with our Powerpack 3 BESS is certified and being documented in the product construction report. TUV Rheinland of North America, Inc., an OSHA's Nationally Recognized Testing Laboratory (NRTL), has issued us a positive Statement of Opinion based on the test report no. US23Q4JP.001. Tesla’s commitment to product safety informs every design decision and has guided 15+ years of experience in battery system designing and manufacturing of our electrical vehicles and energy storage products. Tesla’s approach to product safety involves comprehensive design and tests to cover the entire product lifecycle, the cell, the battery module, the inverter, the thermal system, and the overall system-level assemblies which are closely linked and worked together. The safety of the electrical connections between the Megapacks, the Powerpacks, and the external power supplies will be ensured in the installation site, which is to be done by the Tesla trained and qualified personnels according to the specified installation instructions. Products must be installed and operated with reference to the instructions in the Product Manual. *Model number may be preceded by further alphanumeric character(s) ___________________________________________ Viraj Andrabadu K. P. Sr. Manager, Compliance Engineering vandrabadukurundu@tesla.com 1312 E Warner Ave - 101117461 & 201815044/29/2024 VICINITY MAP AERIAL MAP (N) AUGMENTATION UNITS AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT ATS AUTOMATIC TRANSFER SWITCH BESS BATTERY ENERGY STORAGE SYSTEM BLDG BUILDING CLR CLEAR CONC CONCRETE COMM COMMUNICATION DC DIRECT CURRENT DIA DIAMETER DIST DISTANCE EQ EQUAL EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EA. EACH EMT ELECTRICAL METALLIC TUBING EV ELECTRIC VEHICLE GAB GRADED AGGREGATE BASE GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HVAC HEATING, VENTILATION, & AIR CONDITIONING I CURRENT IMP CURRENT AT MAX POWER INV INVERTER ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT-HOUR LV LOW-VOLTAGE MAX MAXIMUM MIN MINIMUM MV MEDIUM-VOLTAGE (N) NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NRTL NATIONALLY-RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE OC ON CENTER PCC POINT OF COMMON COUPLING PL PROPERTY LINES PLC POWER LINE COMMUNICATION POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC PP POWERPACK PVC POLYVINYL CHLORIDE RSD RAPID SHUTDOWN SCH SCHEDULE SQ. IN. SQUARE INCHES SS STAINLESS STEEL SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS TYP TYPICAL UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY VIF VERIFY IN FIELD W WATT ABBREVIATIONS SHEET INDEX APPLICABLE CODES 2022 CEC 2022 CBC/ASCE 7-16 2022 CFC STRUCTURAL ENGINEER OF RECORD: YOO JIN KIM TESLA, INC. 1216 STEALTH ST. LIVERMORE, CA 94551 P:(925) 292-2724, M:(949) 285-6177 YOKIM@TESLA.COM PROJECT SCOPE INSTALLATION OF BATTERY ENERGY STORAGE SYSTEM AUGMENTATION UNITS AS PART OF PLANNED SERVICE ACTIONS. WORK TO INCLUDE · ANCHORING OF AUGMENTATION UNITS ON EXISTING FOUNDATIONS ·ANCHORING OF POWER SUPPLY CABINETS ON EXISTING FOUNDATIONS ·CONNECTING LOW VOLTAGE ELECTRICAL BETWEEN POWER SUPPLY CABINETS, AUGMENTATION UNITS, AND EXISTING EQUIPMENT 1. WIND DESIGN - DESIGN WIND SPEED = 95 MPH (ULTIMATE) - RISK CATEGORY = II - WIND EXPOSURE = C 2. SEISMIC DESIGN - RISK CATEGORY = II - SEISMIC IMPORTANCE FACTOR = 1.0 - S_S = 1.272 g, S_1 = 0.455 g - SITE CLASS = E - S_DS = 1.018 g, S_D1 = 0.696 g - SEISMIC DESIGN CATEGORY = D - BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT - R = 2.5 / a_p = 1.0 PROJECT TEAM SYSTEM SUMMARY PROJECT LOCATION BATTERY ENERGY STORAGE SYSTEM (BESS) AUGMENTATION AUGMENTATION UNIT RATINGS ENERGY RATING 480 kWh BATTERY BATTERY AUGMENTATION UNIT TYPE PP3 PART # 1930712-00-A QTY 72 DISCHARGE 4 HR SHEET # SHEET TITLE G-001 COVER PAGE G-002 NOTES E-101 ELECTRICAL SITE PLAN E-300 SINGLE LINE DIAGRAM E-301 SINGLE LINE DIAGRAM E-302 SINGLE LINE DIAGRAM E-501 ELECTRICAL DETAILS E-601 CUTSHEETS S-501 STRUCTURAL DETAILS S-502 STRUCTURAL DETAILS DESIGN CRITERIA N S EW N S E W ELECTRICAL ENGINEER OF RECORD: LEO WU TESLA, INC. 3500 DEER CREEK PALO ALTO, CA 94304 P:(415)830-0425 M:(415)830-0425 LEOWU@TESLA.COM CALPINE MEGAPACK SYSTEM AUGMENTATION APN: 016-150-52 PROJECT DESIGNER: ANTHONY FERREIRA TESLA, INC. 3500 DEER CREEK PALO ALTO, CA 94304 AFERREIRA@TESLA.COM PROJECT MANAGER: JUN LEE TESLA, INC. 3500 DEER CREEK ROAD PALO ALTO, CA 94304 LEEJU@TESLA.COM (E) UTILITY METER 1"12" 0 PROPRIETARY AND CONFIDENTIAL AB C D E F G H 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A C H A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 COVER PAGE G-001 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:26 AM JB-9275066 CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N B B B B B B Digitally signed by Leo Wu DN: C=US, E=leowu@tesla.com, O=Tesla Inc., OU=Energy Products Engineering, CN=Leo Wu Location: Palo Alto Reason: I am approving this document. Contact Info: 4158300425 Date: 2024.05.22 16:26:31-07'00' Revision to Bldg #101117461& Elect #20181504 (issued on 4/25/2024) APPROVALS: PLNG - H. Jacinto BLDG - G. Huang PUBLIC WORKS - Y. Soto ELECT - M. Smith 1312 E Warner Ave 2/10/2025 CONCRETE NOTES 1.ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE ACI. 2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL HAVE 2,500 PSI STRENGTH AT 28 DAYS. 3. REINFORCED CONCRETE IN THE FOUNDATION SHALL BE OF NATURAL AGGREGATE CONFORMING TO ASTM C-33. 4. TYPE I/II CEMENT TO MEET ASTM C150. 5. REINFORCING STEEL - ASTM A615 WITH THE FOLLOWING STRENGTHS: SIZE STRENGTH: #4 AND SMALLER GRADE 60 (fy = 60000 PSI) #5 AND LARGER GRADE 60 (fy = 60000 PSI) 6. FABRICATE AND PLACE REINFORCEMENT IN ACCORDANCE WITH ACI PUBLICATION SP-66, ACI DETAILING MANUAL - LATEST EDITION. 7. PLACE CONCRETE IN COMPLIANCE WITH ACI 304. ALL CONCRETE SHALL BE MECHANICALLY VIBRATED. 8. CONFORM TO ASTM C-94 FOR CONCRETE MIXING OPERATIONS. 9. CONCRETE COVER FOR REINFORCEMENT FOR NON-PRESTRESSED, CAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: CONDITION COVER CAST AGAINST EARTH 3" EXPOSED TO WEATHER #5 AND SMALLER 1-1/2" #6 AND LARGER 2" SLAB-ON-GRADE 2" 10.EMBEDS -ALL ITEMS TO BE CAST INTO CONCRETE SUCH AS REINFORCING DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY AND ACCURATELY POSITIONED INTO THE FORMS PRIOR TO PLACING THE CONCRETE. 11.ALL CONCRETE EXPOSED TO THE WEATHER TO BE AIR ENTRAINED AND SHALL CONFORM TO ASTM C-260. 12.PROVIDE CONTINUOUS REINFORCING BARS UNLESS WHERE SPLICES ARE SPECIFICALLY SHOWN ON THE DRAWINGS. 13.CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING CHLORIDE SALTS SHALL NOT BE ADDED TO THE CONCRETE. AUGMENTATION UNIT ANCHORAGE NTS 4.5" MIN EDGE DISTANCE CONCRETE PAD AALTERNATE AUGMENTATION UNIT ANCHORAGE NTS CONCRETE PAD 3 8" THICK A36 PAINTED STEEL PLATE TOP VIEW (2) 5 8" DIA. A325 GALV. THRU BOLTS B CONCRETE PAD 1" TYP.1" TYP. NOTCH CONCRETE TO ACCOMMODATE BOLT HEAD 4.5" MIN ANCHOR EDGE DISTANCE 5/8" DIA SS HILTI KWIK BOLT TZ2 INSTALLED PER ESR-4266 W/ 4.5" NOMINAL EMBED OR 5/8" DIA. SS HILTI HIT-HY 200 V3 ADHESIVE ANCHOR INSTALLED PER ESR-4868 W/4.5" EMBED FILL W/ NON-SHRINK GROUT EA. EA. 1" TYP. 5.5" MAX 6" SIDE OF (N) AUGMENTATION UNIT EDGE OF CONCRETE PAD WHERE OCCURS SIDE OF (E) MEGAPACK 6" MIN 5/8" DIA SS HILTI KWIK BOLT TZ2 INSTALLED PER ESR-4266 W/ 4.5" NOMINAL EMBED OR 5/8" DIA. SS HILTI HIT-HY 200 V3 ADHESIVE ANCHOR INSTALLED PER ESR-4868 W/4.5" EMBED POWER CABINET ANCHORAGE NTSC 2.5" MIN EDGE DISTANCE CONCRETE PAD 1/2" DIA SS HILTI KWIK BOLT TZ2 INSTALLED PER ESR-4266 W/ 3" NOMINAL EMBED OR 1/2" DIA. SS HILTI HIT-HY 200 V3 ADHESIVE ANCHOR INSTALLED PER ESR-4868 W/3" EMBED (E) MEGAPACK 2, TYP. 51 2" 4" 4" 3'-1" 4" 4" 6" 1'-7"3' 2' (N) POWER SUPPLY CABINET (N) AUGMENTATION UNIT, TYP. (N) WORKING CLEARANCE (N) WORKING CLEARANCE10" 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A C H A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 STRUCTURAL DETAILS S-501 REV: B IFP VQUIRINDONGOPLOT DATE: 5/10/2024 10:26 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N N S EW ENLARGED STRUCTURAL SITE FOR MP2 - PLAN VIEW 1/2" = 1'-0"0 1/2 1/4 A & B - C - POWER SUPPLY CABINET NTS Yoo Jin Kim Digitally signed by Yoo Jin Kim Date: 2024.05.10 10:29:45 -07'00' 1312 E Warner Ave 2/10/2025 POWER SUPPLY CABINET ANCHORAGEB (E) COLUMN 1/2" DIA SS OR GALVANIZED THROUGH BOLT (A307 OR BETTER) (E) GRADE ALTERNATE AUGMENTATION UNIT ANCHORAGE NTS (E) GRAVEL 1/2" DIA. SS OR GALVANIZED THROUGH BOLT (A307 OR BETTER) M18 - 5/8 HOLLO-BOLT BY LINDAPTER, PER ESR-3330, TYP OF 2 (E) GRAVEL (N) (2) HSS 6x2x3/8 ATTACHED W/ C4x7.25 MEMBER SECTION - AA SECTION - BB BOTTOM OF (N) AUGMENTATION UNIT 3"@6" 1/2" DIA. SS OR GALVANIZED THROUGH BOLT (A307 OR BETTER) LENGTH TO COVER ANCHOR AUGMENTATION EDGE (E) COLUMN (E) COLUMN SIDE OF (N) POWER SUPPLY (E) GRAVEL (E) GRADE 2" MIN. (E) C12 CHANNEL (E) C12 CHANNEL 1.5" MIN 6" FROM FACE OF MEGAPACK TO FACE OF AUGMENTATION UNIT SIDE OF (E) MEGAPACK 1'-81 4" (E) W8 COLUMN (12) PER CHANNEL 3'-6"3'-6"3'-6" 6" 6" 1.5" MIN CLEAR FROM HSS STEEL EDGE 6" 4"6"6" 6" MIN 6" 4"1' 12" 1.5" MIN CLEAR FROM HSS STEEL EDGE (E) C12 CHANNEL 1'-81 4" (E) W8 COLUMN (12) PER CHANNEL 3'-6"3'-6"3'-6" 6" 6" 1.5" MIN CLEAR FROM HSS STEEL EDGE 6" 4"6"6" 6" MIN 6" 4"1' 12" 1.5" MIN CLEAR FROM HSS STEEL EDGE (E) C12 CHANNEL 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A C H A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 STRUCTURAL DETAILS S-502 REV: B IFP VQUIRINDONGOPLOT DATE: 5/10/2024 10:26 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N NS E W 0 1/2 1/4 B -A - 6"4" SIDE OF (N) AUGMENTATION UNIT (ABOVE HSS STEEL TUBE AND CHANNEL) SIDE OF (E) MEGAPACK (2) M18 - 5/8 HOLLO-BOLT BY LINDAPTER, PER ESR-3330 (N) (2) HSS 6x2x3/8 ATTACHED W/ C4x7.25 MEMBER 1'-9" TOP VIEW 3" 1.5" MIN CLEAR FROM HSS STEEL EDGE 1/2" DIA. SS OR GALVANIZED THROUGH BOLT (A307 OR BETTER) 6" BB AA NS E W ENLARGED STRUCTURAL SITE MP2 XL - PLAN VIEW 1/2" = 1'-0"0 1/2 1/4 B -A - 3"@6" A (N) (2) HSS 6X2X3/8 ATTACHED W/ C4X7.25 MEMBER (E) MEGAPACK 2 XL (WT=84,000 LBS)(N) AUGMENTATION UNIT (WT=10,500 LBS) (N) POWER SUPPLY (WT= 364 LBS) SIDE OF (E) MEGAPACK (2) M18 - 5/8 HOLLO-BOLT BY LINDAPTER, PER ESR-3330 1.5" MIN CLEAR FROM HSS STEEL EDGE SIDE OF (N) AUGMENTATION UNIT (ABOVE HSS STEEL TUBE AND CHANNEL) (N) (2) HSS 6x2x3/8 ATTACHED W/ C4x7.25 MEMBER 1/2" DIA. SS OR GALVANIZED THROUGH BOLT (A307 OR BETTER) 6"4"1'-9"3" 6" BB AA B EDGE OF (N) HSS STEEL EDGE OF (N) HSS STEEL Yoo Jin Kim Digitally signed by Yoo Jin Kim Date: 2024.05.10 10:29:38 -07'00' 1312 E Warner Ave 2/10/2025 (E) MEGAPACK 2 TYP. OF 28 (N) AUGMENTATION UNIT, TYP. of 72 (N) POWER SUPPLY CABINET, TYP. 1 PER AUGMENTATION UNIT (E) TRANSFORMER, TYP. FUTURE AUGMENTATION UNIT, TYP. (E) MEGAPACK 2 XL TYP. OF 44 AREAS OF INTEREST (N) AUGMENTATION UNIT (E) LIGHT POLE (E) UTILITY POLE PROPERTY LINE SITE LEGEND (E) FENCE (E) MEGAPACK 2 ENCLOSURE FUTURE AUGMENTATION UNIT (E) MEGAPACK 2 XL ENCLOSURE 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 ELECTRICAL SITE PLAN E-101 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N NS E W ELECTRICAL SITE PLAN 1" = 20'0 20'40' B B B 1312 E Warner Ave 2/10/2025 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 SINGLE LINE DIAGRAM E-300 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N REFERENCE ONLY SEE PREVIOUS PERMIT 1312 E Warner Ave 2/10/2025 STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-3.1B' 'AC-3.1A''AC-3.1C' TESLA MEGAPACK 3.1B TESLA MEGAPACK 3.1A TESLA MEGAPACK 3.1D TESLA MEGAPACK 3.1C 'AC-3.1D' 'MV-3.2' 8" PVC WITH: (3) 1/C 1000MCM AL MV-105, 15KV 100% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) BESS TRANSFORMER 3.1 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.43%, X/R=9.20 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 3.2 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.31%, X/R=9.10 NOTES: 1. XOB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XOA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 3.3 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.43%, X/R=9.13 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 3.4 1.800 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.62%, X/R=8.88 NOTES: 1. Xo TO BE BONDED TO GROUND PAD IN LV CABINET. STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-3.2B' 'AC-3.2A''AC-3.2C' TESLA MEGAPACK 3.2B TESLA MEGAPACK 3.2A TESLA MEGAPACK 3.2D TESLA MEGAPACK 3.2C 'AC-3.2D' 'MV-3.2' 8" PVC WITH: (3) 1/C 1000MCM AL MV-105, 15KV 100% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC 750MCM CU GEC INTEGRATED FUSE, SERVICEABLE ONLY BY TESLA FACTORY INSTALLED DC CONNECTION TORQUE AC TERMINALS PER INSTALLATION MANUAL 1600A 3P LSIG BATTERY / CONVERTER MODULE (TYP) FACTORY INSTALLED INTEGRATED THERMAL & OVER CURRENT PROTECTION 480V INVERTER AC OUTPUT UNGROUNDED DC SYSTEM INTEGRATED GFCI CTRL 1" EMT WITH: CU CAT 6A F/UTP SHIELDED CABLE TO FNE ENCLOSURE WIREWAY WITH: 1#750MCM EGC CU-XHHW2-TC & 4 SETS OF: 3#750MCM AL-XHHW2-TC G TESLA MEGAPACK 4.1A 4-HOUR RATED 480V, 1,082.5A OUTPUT 761.9 KW, 900.0KVA 3,047.6 kWh CAPACITY AC & DC GFCI 85kAIC NEMA 3R NOTE: CONTRACTOR IS RESPONSIBLE FOR INSTALLING TESLA MEGAPACK PER INSTALLATION MANUAL TYPICAL TESLA MEGAPACK STATIC SHIELD CLF EXP GXoBGXoA 'MV-3.1' 2 SETS OF 5" PVC EACH WITH: (3) 1/C 500MCM AL MV-105, 15KV 133% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) TO T1 SWITCHGEAR BREAKER 52-F3 SEE E300 G 2#4/0 CU GEC 'AC-4.1B' 'AC-4.1A''AC-4.1C' TESLA MEGAPACK 4.1B TESLA MEGAPACK 4.1D TESLA MEGAPACK 4.1C 'AC-4.1D' PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC 'MV-3.1' 2 SETS OF 5" PVC EACH WITH: (3) 1/C 500MCM AL MV-105, 15KV 133% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) TO T1 SWITCHGEAR BREAKER 52-F3 SEE E300 STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-3.3B' 'AC-3.3A''AC-3.3C' TESLA MEGAPACK 3.2B TESLA MEGAPACK 3.3A TESLA MEGAPACK 3.3D TESLA MEGAPACK 3.3C 'AC-3.3D' 'MV-3.3' 8" PVC WITH: (3) 1/C 1000MCM AL MV-105, 15KV 100% EPR INCLUDE 1#2/0G CU-XHHW2 (600V) PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC STATIC SHIELD CLF EXP GXo G 2#4/0 CU GEC 'AC-3.4B' 'AC-3.4A''AC-3.4C' TESLA MEGAPACK 3.4B TESLA MEGAPACK 3.4A TESLA MEGAPACK 3.4D TESLA MEGAPACK 3.4C 'AC-3.4D' 750MCM CU GEC (3) SAs 10kV 8.4MCOV BESS TRANSFORMER 4.1 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.09%, X/R=8.49 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 4.2 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.38%, X/R=9.0 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-4.2B' 'AC-4.2A''AC-4.2C' TESLA MEGAPACK 4.2B TESLA MEGAPACK 4.2A TESLA MEGAPACK 4.2D TESLA MEGAPACK 4.2C 'AC-4.2D' PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC 750MCM CU GEC BESS TRANSFORMER 4.3 3,600 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.36%, X/R=9.18 NOTES: 1. XoB TO BE BONDED TO GROUND PAD IN LV CABINET B. 2. XoA TO BE REMOVED OR CAPPED FROM USE. BESS TRANSFORMER 4.4 1.800 KVA PAD MOUNTED FR-3 COOLED KNAN PRI: 13.8kV, 3∅, 3W SEC: 480Y/277V, 3∅, 4W Z=6.65%, X/R=8.88 NOTES: 1. Xo TO BE BONDED TO GROUND PAD IN LV CABINET. STATIC SHIELD CLF EXP GXoBGXoA G 2#4/0 CU GEC 'AC-4.3B' 'AC-4.3A''AC-4.3C' TESLA MEGAPACK 4.2B TESLA MEGAPACK 4.3A TESLA MEGAPACK 4.3D TESLA MEGAPACK 4.3C 'AC-4.3D' PROVISIONAL 750MCM CU GEC TO BE CAPPED AND NOT CONNECTED 750MCM CU GEC STATIC SHIELD CLF EXP GXo G 2#4/0 CU GEC 'AC-4.4B' 'AC-4.4A''AC-4.4C' TESLA MEGAPACK 4.4B TESLA MEGAPACK 4.4A TESLA MEGAPACK 4.4D TESLA MEGAPACK 4.4C 'AC-4.4D' 750MCM CU GEC (3) SAs 10kV 8.4MCOV 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 SINGLE LINE DIAGRAM E-301 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N REFERENCE ONLY MP 2 SEE PREVIOUS PERMIT 1312 E Warner Ave 2/10/2025 BATTERY ENERGY STORAGE SYSTEM EQUIPMENT:GENERAL NOTES POD - SCE JOHANNA SUBSTATION 220kV M M PR 3 TRANSFORMER "T2" 33/44/55MVA 69KV DELTA PRIMARY 13.8KV WYE-G SECONDARY PR 5 5 2 2 2 6 7 8 (E) CONTROL HOUSE SANTA ANA PHASE III (E) SUBSTATION MV CONDUIT SCHEDULE 8 LEGEND: 2 3 4 5 UTILITY & CAISO METER KEYED NOTES 1 7 ɸ SANTA ANA STORAGE PHASE III 40 MWAC - 4 HOUR EQUIPMENT NAMING CONVENTION 6 6 1312 E. WARNER AVE. SANTA ANA, CA 92705 MV FEEDER SCHEDULE 4 1 1 ONE-LINE DIAGRAM -SCALE: NTS 222028 WRY E-2.0 CG NONE 52 ON E L I N E D I A G R A M 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 SINGLE LINE DIAGRAM E-302 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N REFERENCE ONLY MP 2 XL SEE PREVIOUS PERMIT B 1312 E Warner Ave 2/10/2025 (E) MEGAPACK TO XFMR 480/277V 3Φ 4W FUTURE AUGMENTATION CONNECTIONS (E) 1600A/3P (N) POWERPACK 3 AUGMENTATION UNIT, TYP. EXISTING BATTERY MODULES 300 MCM CU, XHHW-2 (3) WIRE + GND A GROUNDING DIAGRAM G (N) POWERPACK 3 AUGMENTATION UNIT (N) EGC 4/0 AWG CU. G (E) MEGAPACK 2 TO TRANSFORMER (E) GROUNDED CONDUCTOR AND CONNECTIONS LEGEND IRREVERSIBLE SPLICE OR CRIMP PER NEC 250.64(C) NEC 250.52(A)-COMPLIANT GROUNDING ELECTRODE PRIMARY OR SECONDARY COMMON TERMINAL, AS APPLICABLE G TERMINAL ON NEUTRAL OR GROUND BUSBAR N O NEUTRAL BUSBAR GROUND BUSBAR E701.118 DC CONDUIT AND JUNCTION BOXES LABEL RB POWER SUPPLY CABINET WARNING LABEL NTSE NOTE: 1. MARKING PER ART 690.56 2. REFLECTIVE, WATER RESISTANT MATERIAL 3. RED BACKGROUND 4. WHITE LETTERING, ALL CAPITAL LETTERS, ARIAL NON-BOLD FONT 5. TEXT HEIGHT: 3/8" MIN. CAUTION: SHOCK HAZARD 6" 3 4" B TYP. AUGMENTED MEGAPACK 2 OR MEGAPACK 2 XL WITH POWER SUPPLY TESLA SUPPLIED KEPS NUT WITH INTEGRATED SPRING WASHER. TORQUE TO MFR SPECIFICATIONS & MARK WITH PAINT PEN AFTER TORQUING. UL-LISTED, 600V-RATED CRIMP. ONLY USE MFR-APPROVED CRIMP TOOL & DIE FOR CONNECTOR SIZE. APPLY ANTIOXIDANT COMPOUND BEFORE CRIMPING. BUSBAR OR TRANSFORMER SPADE TERMINATIONS TO BE COMPRESSION LUGS ONLY. BUSBAR WITH INTEGRATED STUD E501.101 COMPRESSION LUG TERMINATION DETAIL RA COMPRESSION LUG TERMINATION DETAIL NTSC QTY (1) - 4 HR RATED 480V 480 kWh 85kAIC NEMA 3R (N) POWERPACK 3 POWER SUPPLY CABINET, TYP. TO PP3 DC LOADS (N) BOLTED CONNECTION TO AC BUSBAR (N) PSR FUSES 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 ELECTRICAL DETAILS E-501 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N SHEET NOTES: 1.NO MORE THAN 72 AUGMENTATION UNITS TO BE INSTALLED. 2.NO MORE THAN ONE AUGMENTATION UNIT PER MEGAPACK. 3.EXACT LOCATION OF EACH AUGMENTATION UNIT TO BE DETERMINED AT TIME OF INSTALLATION. B B B B 1312 E Warner Ave 2/10/2025 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 CUTSHEETS E-601 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N 1312 E Warner Ave 2/10/2025 ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM TESLA OF ANY DISCREPANCIES. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE SUBCONTRACTORS SOLE EXPENSE. SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TESLA FOR APPROVAL BEFORE MAKING ANY CHANGES. DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM TESLA PLACES LIABILITY ON THE SUBCONTRACTOR. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE DRAWINGS. NEW PAVEMENT INSTALLED AS PART OF THIS PROJECT SHALL MATCH EXISTING PAVEMENT SECTION. ASPHALT AND GAB DEPTHS SHALL BE MAINTAINED. GENERAL NOTES GENERAL NOTES 1.ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. 2.ALL WIRING SHALL BE MANAGED IN A PROFESSIONAL, WORKMAN-LIKE MANNER AND MUST BE SUPPORTED, SECURED, AND PROTECTED TO PREVENT DAMAGE. 3.AC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER ART 210.5 OR 215.12. UNLESS OTHERWISE REQUIRED BY ART 210.5(1) OR AHJ, COLOR-CODING OF POWER CONDUCTORS SHALL BE AS FOLLOWS: CONDUCTOR 277/480V 120/208V PHASE A BROWN BLACK PHASE B ORANGE RED PHASE C YELLOW BLUE NEUTRAL GRAY WHITE 4.DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED PER ART 210.5 OR 215.12: CONDUCTOR STD COLOR ALT COLOR DC+RED RED-STRIPED DC-BLACK BLACK-STRIPED 5.TERMINATIONS OF AC, DC, AND COMMUNICATIONS CONDUCTORS SHALL BE PROFESSIONALLY AND LEGIBLY LABELED WITH CIRCUIT SCHEDULE IDENTIFIER, CONDUCTOR SIZE (AS APPLICABLE) AND TERMINATION TORQUE. 6.ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, ENGINEERING APPROVAL SHALL BE OBTAINED PRIOR TO EQUIPMENT MODIFICATION, AND THE EQUIPMENT SHALL BE RELISTED BY A SUITABLE NRTL. 7.UNDERGROUND CONDUCTORS & CABLES TO BE INSTALLED IN CONDUIT UON. 8.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NRTL LISTING. 9.REFER TO MANUFACTURER'S CURRENT PLANNING AND INSTALLATION MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. 10.ALL CONDUCTOR TERMINATIONS ON BUSSING OR TRANSFORMER SPADES SHALL BE MADE WITH HIGH-PRESS CRIMP LUGS UON. 11.ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY INSTALLED WITH BEST PRACTICES INCLUDING BUT NOT LIMITED TO: ·USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE ·ALLOWANCE FOR MOVEMENT DUE TO THERMAL EXPANSION/CONTRACTION ·PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION COMPOUND ·USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO REQUIRED SETTINGS 12.DUCT SEAL COMPOUND SHALL BE APPLIED WHEREVER CONDUITS TRANSITION INDOOR/OUTDOOR OR UNDERGROUND/ABOVEGROUND. REFER TO EQUIPMENT NOTES FOR ADDITIONAL DUCT SEAL REQUIREMENTS. 13.BELL ENDS SHALL BE INSTALLED WHEREVER CONDUIT ENTERS EQUIPMENT FROM UNDERGROUND AND WHEREVER POTENTIAL FOR DAMAGE TO CONDUCTORS IS PRESENT AT ANY POINT. BELL ENDS SHALL NOT PREVENT THE USE OF GROUNDING FITTINGS OR COUPLERS WHEN REQUIRED. 14.ALL STUB-UPS WITHIN FLOOR-MOUNTED EQUIPMENT SHALL BE 3-5" ABOVE FINISHED GRADE. 15.ALL CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE SHALL BE RIGID GALVANIZED STEEL. 16.GROUND LUGS SHALL BE RATED FOR THEIR ENVIRONMENT AND CONDITION OF USE. ELECTRICAL NOTES 1.LOAD SIDE INTERCONNECTIONS SHALL COMPLY WITH NEC ART 705.12(B). 2.WHERE THE INTERCONNECTION POINT OCCURS ON FEEDERS, THE FEEDER AMPACITY SHALL NOT BE LESS THAN THE SUM OF ALL THE SOURCES CONNECTED TO THE FEEDER UNLESS THE FEEDER IS PROTECTED ON THE LOAD SIDE OF THE INTERCONNECTION POINT WITH OVERCURRENT PROTECTION NO GREATER THAN THE AMPACITY OF THE FEEDER. 3.TAP CONNECTIONS SHALL COMPLY WITH ART 240.21(B). 4.WHERE THE SUM OF ALL THE OVERCURRENT DEVICE RATINGS ON THE PANEL LOAD SIDE OF A MAIN OVERCURRENT PROTECTION DEVICE ARE LESS THAN THE RATING OF THE PANEL, PERMANENT WARNING LABELS WITH THE FOLLOWING WORDING MUST BE APPLIED: WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. 5.WHERE THE SUM OF THE UTILITY OVERCURRENT DEVICE AND 125% OF INVERTER OUTPUT CIRCUIT CURRENT DOES NOT EXCEED 120% OF THE RATING OF THE BUSBAR, THE INTERCONNECTION POINT MUST BE ON THE OPPOSITE END OF THE BUSBAR FROM THE INCOMING UTILITY SOURCE AND A PERMANENT WARNING LABEL MUST BE APPLIED TO THE INTERCONNECTION POINT. 6.LOAD SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE THE NRTL LISTING OF THE EQUIPMENT. WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, EQUIPMENT MUST BE RELISTED BY AN APPROVED NRTL SUITABLE FOR THE EQUIPMENT. UTILITY-INTERACTIVE INVERTER LOAD-SIDE INTERCONNECTION NOTES 1.CAT5E/6 SHIELDED CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS OF INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL DISTANCE OF 328 FEET (100M) PER CHAIN. 2.RS485 CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS OF INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL DISTANCE OF 3280 FEET (1000M) PER CHAIN. 3.SWITCHES, METERS, POWERPACK CONTROLLERS, CT'S, AND PT'S, AND CONDUCTORS MARKED "PRE-INSTALLED" IN THE LINE DIAGRAM WILL ARRIVE TO SITE PRE-INSTALLED WITHIN THE SWITCHBOARD, AND WILL NOT REQUIRE ANY FIELD INSTALLATION OR MODIFICATION OF ANY KIND. 4.FIBER OPTIC CABLE RUNS SHALL UTILIZE OUTDOOR DUCT OR DIRECT BURIAL RATED SINGLE MODE (OS2) CABLES COMPATIBLE WITH COMMUNICATION WAVELENGTHS BETWEEN 1310 - 1550 NM. COMMUNICATION NOTES GENERAL NOTES 1.REFER TO THE SPECIFIC PRODUCT MANUFACTURER'S INSTALLATION AND OPERATION MANUAL FOR MORE INFORMATION. 2.BATTERY ENERGY STORAGE SYSTEM (BESS) SHALL BE SERVICED ONLY BY MANUFACTURER-CERTIFIED TECHNICIANS. 3.SECONDARY CONTAINMENT IS NOT REQUIRED FOR THE BATTERY BESS. 4.BATTERY PACK DC CONNECTIONS TO BESS INVERTER SHALL ONLY BE MADE WITH MANUFACTURER-PROVIDED CONDUCTOR HARNESSES. 5.BESS DISCONNECTING MEANS SHALL BE LABELED PER ART 706.7(D). BESS AND INTERCONNECTION SHALL BE LABELED PER ART 706.11. BESS NOTES SITE LEGEND (E) ACCESSIBLE PARKING SPACE (E) LIGHT POLE FH (E) FIRE HYDRANT G E SS SD T TV ? W GV HB IV WV WR T CO (E) STORM MANHOLE (E) GUY WIRE - ELECTRIC (E) HOSE BIB (E) GAS VALVE (E) IRRIGATION VALVE (E) WATER VALVE (E) SPRINKLER HEAD (E) WATER RISER (E) SPRINKLER HEAD (E) CLEANOUT (E) ELECTRIC MANHOLE (E) GAS MANHOLE (E) SANITARY SEWER MANHOLE (E) TELEPHONE MANHOLE (E) TELEVISION MANHOLE (E) UNKNOWN MANHOLE (E) POTABLE WATER MANHOLE (E) UTILITY POLE - ELECTRIC (E) UTILITY POLE - TELEPHONE (E) GUY WIRE (E) TREE UE (E) UNDERGROUND ELECTRIC LINE ST (E) UNDERGROUND STORM DRAIN LINE WL (E) UNDERGROUND WATER LINE UG (E) UNDERGROUND GAS LINE OE (E) OVERHEAD ELECTRIC LINE UT (E) UNDERGROUND TELEPHONE LINE SS (E) UNDERGROUND SANITARY SEWER LINE (E) VENT PIPE (E) ROOF ACCESS HATCH (E) EXHAUST FAN (E) SKYLIGHT (E) HVAC UNIT (E) OPERABLE SKYLIGHT (E) CONDENSATION CONDUIT LINEWL GAS ELE (E) GAS CONDUIT LINE (E) ELECTRICAL CONDUIT LINE (E) UTILITY POLE GENERAL NOTES 1.TESLA, AT THE TIME OF INSTALLATION, SHALL CONFIGURE THE AUGMENTED MEGAPACKS SUCH THAT: 1.1.THE INTERNAL MEGAPACK CONTROLLER ADJUSTS THE MAXIMUM ALLOWABLE CURRENT OF THE INVERTERS WITH FIRMWARE SO THAT THE AUGMENTED MEGAPACK'S CURRENT CAPABILITY AND THUS KVA RATING ARE MAINTAINED, REGARDLESS OF THE NUMBER OF INVERTERS. 1.2.THE CURRENT IS LIMITED AT THE INVERTER LEVEL, THE SHORT-CIRCUIT CONTRIBUTION OF THE AUGMENTED MEGAPACK REMAINS UNCHANGED. BESS AUGMENTATION NOTES 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 / 1 6 / 2 4 A CH A N G E S T O E L E C T R I C A L S H E E T S 05 / 0 3 / 2 4 B AD D I T I O N A L A U G M E N T A T I O N U N I T S AD D E D B CA L P I N E I I & I I I 13 1 2 E W A R N E R A V E SA N T A A N A , C A 9 2 7 0 5 NOTES G-002 REV: B IFP VQUIRINDONGOPLOT DATE: 5/22/2024 9:22 AM JB-9275066   CA L P I N E ME G A P A C K S Y S T E M A U G M E N T A T I O N 1312 E Warner Ave 2/10/2025 EQUIPMENT CONCRETE PAD / ANCHORAGE CALCULATIONS PROJECT: Calpine - Phase 2 & 3 - Megapack System Aygmentation 1312 East Warner Avenue Santa Ana, CA 92264 REPORT PREPARED FOR: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 OWNER: Calpine Calpine 1312 East Warner Avenue Santa Ana, CA 92264 PROJECT DESIGNED BY: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 1 1312 E Warner Ave 2/10/2025 ASCE Hazards Report Address: 1312 E Warner Ave Santa Ana, California 92705 Standard:ASCE/SEI 7-16 Latitude:33.715594 Risk Category:II Longitude:-117.853724 Soil Class:E - Soft Clay Soil Elevation:62.916768952312914 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Wed Mar 06 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Wed Mar 06 2024 2 1312 E Warner Ave 2/10/2025 SS : 1.272 S1 : 0.455 F a : N/A F v : N/A SMS : N/A SM1 : N/A SDS : N/A SD1 : N/A T L : 8 PGA : 0.537 PGA M : 0.625 F PGA : 1.163 Ie : 1 C v : N/A Seismic Site Soil Class: Results: Data Accessed: Date Source: E - Soft Clay Soil USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Wed Mar 06 2024 Page 2 of 3https://ascehazardtool.org/Wed Mar 06 2024 3 1312 E Warner Ave 2/10/2025 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Wed Mar 06 2024 4 1312 E Warner Ave 2/10/2025 1. Lateral Loads Calculation for Equipment (2022 CBC) 1.1 Earthquake Load Latitude =33.7156 Longitude =-117.8537 Soil Site Class =E Seismic Use Group =II From Spectrum Data: (from output of Seismic Design Parameters) SS =1.272 g SMS =1.5264 g SDS = 2/3 SMS =1.018 g S1 =0.455 g SM1 =1.045 g SD1 = 2/3 SM1 =0.696 g Seismic Design Category =D  =1.0 (ASCE 7, 12.3.4.1) Seismic Design Force :(for Nonstructural Components) R =2.5 ap =1.0 (ASCE 7, Table 13.6-1) Ip =1.0 z/h =0.0 Powerpack 3.0 Wp =11,000 lbs Fp = [0.4 ap SDS Wp / (Rp/Ip)] x (1+2(z/h))(ASCE 7, 13.3-1) =1,791.0 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =17,909.8 lbs =3358.1 lbs Therefore Fp =3,358 lbs Power Supply Cabinet Wp =364 lbs Fp = [0.4 ap SDS Wp / (Rp/Ip)] x (1+2(z/h))(ASCE 7, 13.3-1) =59.3 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =592.7 lbs =111.1 lbs Therefore Fp =111 lbs 5 1312 E Warner Ave 2/10/2025 1.2 Wind Loads on Equipment (2022 CBC) Basic Wind Speed =95 mph Exposure =C Mean Roof Height (h) =8.4 ft < 60 ft Wind Loads on Other Structures (ASCE 7-10, 29.5 / ASCE 7-16, 29.4) Powerpack 3.0 W =5.9 ft D =3.6 ft H =8.4 ft Eff. Wind Area =49.3 ft2 30.1 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16, Fig. 29.4-1) =1.32 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =17.7 psf Threfore, p =19.8 psf Wind Force W =977 lbs 6 1312 E Warner Ave 2/10/2025 Power Supply Cabinet W =2.0 ft D =1.6 ft H =5.9 ft Eff. Wind Area =11.8 ft2 9.4 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16, Fig. 29.4-1) =1.35 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =17.7 psf Threfore, p =20.2 psf Wind Force W =239 lbs 7 1312 E Warner Ave 2/10/2025 1.3 Anchor Bolt Design Powerpack 3.0 (on Steel Beam)2022 CBC Wind=977 lbs SDC= D EQ*Ω=3,358 lbs Ω= 1 (Anchor into Steel Beam) Load combination used for the design: 0.696 DL + 1.0 EQ (0.9-0.2SDS) if EQ Governs 1 V =3,358 lbs 1 V x 0.3=1,007 lbs (orthogonal direction) Hc =8.4 ft. COG =4.2 ft. Dc =3.8 ft.Wc =3.8 ft. Wp =0.696 DL =7,661 lbs MOT =V x COG MOT =V x COG =14,027 lb-ft =4,208 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =14,445 lb-ft =14,579 lb-ft M =MOT - MR M =MOT - MR =-418 lb-ft =-10,370 lb-ft Anchor Bolts for Powerpack 3.0 Bolt Number =4 Dia. of Bolt =1/2 inch / A307 or better T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =0 lbs. =0 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =840 lbs. =252 lbs. Max. Tension, T =0 lbs. Max. Shear, V =876 lbs. Fnv =24.0 ksi.Fnt =45.0 ksi.=0.75 A =  r2 =0.196 in2 fv =V / A =4.46 ksi. < Fv =18.0 ksi. (O.K.) ft =T / A =0.00 ksi. < Ft =33.8 ksi. (O.K.) V Wp Hc T Dc 8 1312 E Warner Ave 2/10/2025 9 1312 E Warner Ave 2/10/2025 Power Supply Cabinet (on Steel Beam)2022 CBC Wind=239 lbs SDC= D EQ*Ω=111 lbs Ω= 1 (Anchor into Steel Beam) Load combination used for the design: 0.900 DL + 1.0 W (0.9-0.2SDS) if EQ Governs 1 V =239 lbs 1 V x 0.3=72 lbs (orthogonal direction) Hc =5.9 ft. COG =3.0 ft. Dc =0.7 ft.Wc =0.7 ft. Wp =0.9 DL =328 lbs MOT =V x COG MOT =V x COG =707 lb-ft =212 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =109 lb-ft =109 lb-ft M =MOT - MR M =MOT - MR =598 lb-ft =103 lb-ft Anchor Bolts for Power Supply Cabinet Bolt Number =4 Dia. of Bolt =1/2 inch / A307 or better T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =448 lbs. =77 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =60 lbs. =18 lbs. Max. Tension, T =525 lbs. Max. Shear, V =62 lbs. Fnv =24.0 ksi.Fnt =45.0 ksi.=0.75 A =  r2 =0.196 in2 fv =V / A =0.32 ksi. < Fv =18.0 ksi. (O.K.) ft =T / A =2.68 ksi. < Ft =33.8 ksi. (O.K.) V Wp Hc T Dc 10 1312 E Warner Ave 2/10/2025      ! " #$% & ' "  & (23 4"!556789:;<=5;7" !   "! J9<869!;8 "! JMNQ4;8S6 TA"UA 4967"UA;99: 6=5;8;RV9K7<$; 6<';AA8<9$;W<$867@;A:9 WR !8;;X; TA7<$9: 46A (!;7Y$;6<A;98;7; 6<W<$867AZK;<55;[67$< 6< @_ _)T`[8# 4";:S8% 6< @_ _)T`[8# 4";:S8%*QNaghFi;99:!87;AA'<86_jklml 6=K9<869 n@n ZS;7;=<U==6$$7A !5<9 49o>S "6Z<K;(JT[8 p9o>S "6Z<K;qrsmstuv9A;[678SAA5<9 !5<9 ZS;7;=<U==6$$7A 6$<8696[=<U==69A5<9 !5<9 6< 6=K9<869 n@!;$869A;[678SAA5<9 qrsm4 "55;4<U==!S;<7!87;AA'<86_jT[8 p "55;wJ'<86_w)@;[;$8696Z9Z<77<9A;98@;[;$869 )9 J'<86_ x_5Z<77<9A;98@;[;$869 9 '<86_6Z9Z<768<@;[;$869 9 '<86_ x_)5Z<768<@;[;$869 9 !5<9   y9R9z<!5<9  n@nJ 9z<}Q~MQQQOM^O],O€NbNObQ!5<9 !==<7R6[46=;98p<;A !==<7R6[!9<869 4<U!87;AA'<86A4 p =<U4'= p9R44<U >So49R K p4<U49R98 ;9:8S_[8    J J  ( J )_[8  ( (    (  )_[8       (  )_[8       (  )_[8  J J    (  ) 11 1312 E Warner Ave 2/10/2025      ! " #$% & ' "  & (23 4"!556789:;<=B9<869 !55678 !55678EGHI L<;A9 >!<7K76= 6< <A;A ) )) ) ( ( ( (S )( )() ) 12 1312 E Warner Ave 2/10/2025 Powerpack 3.0 (on Concrete Pad)2022 CBC Wind=977 lbs SDC= D EQ*Ω=6,716 lbs Ω= 2 Load combination used for the design: 0.696 DL +1.0 EQ (0.9-0.2SDS) if EQ Governs 1 V =6,716 lbs 1 V x 0.3=2,015 lbs (orthogonal direction) Hc =8.4 ft.COG =4.2 ft. Dc =3.8 ft.Wc =3.8 ft. Wp =0.696 DL =7,661 lbs MOT =V x COG MOT =V x COG =28,054 lb-ft =8,416 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =14,445 lb-ft =14,579 lb-ft M =MOT - MR M =MOT - MR =13,609 lb-ft =-6,162 lb-ft Anchor Bolts for Powerpack 3.0 Bolt Number =4 T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =1,805 lbs.=0 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =1,679 lbs.=504 lbs. V Wp Hc T Dc 13 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Powerpack 3 Page: Specifier: E-Mail: Date: 1 Yoo Jin Kim yokim@tesla.com 5/6/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 5/8 (2 3/4) hnom1 Item number: 2210278 KB-TZ2 5/8x4 3/4 SS304 Effective embedment depth: hef,act = 2.750 in., hnom = 3.250 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2023 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.625 in. Anchor plateR : lx x ly x t = 6.000 in. x 2.063 in. x 0.625 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: present, shear: present; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, ft.lb] 14 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Powerpack 3 Page: Specifier: E-Mail: Date: 2 Yoo Jin Kim yokim@tesla.com 5/6/2024 1.1 Design results Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 1,805; Vx = 504; Vy = 1,679; Mx = 0.000; My = 0.000; Mz = 0.000; yes 89 15 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Powerpack 3 Page: Specifier: E-Mail: Date: 3 Yoo Jin Kim yokim@tesla.com 5/6/2024 2 Proof I Utilization (Governing Cases) Design values [lb]Utilization Loading Proof Load Capacity bN / bV [%]Status Tension Concrete Breakout Failure 1,805 2,693 68 / -OK Shear Concrete edge failure in direction y+1,753 3,197 - / 55 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.670 0.548 5/3 89 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 16 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Powerpack 3 Page: Specifier: E-Mail: Date: 4 Yoo Jin Kim yokim@tesla.com 5/6/2024 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 17 1312 E Warner Ave 2/10/2025 Power Supply Cabinet (on Concrete Pad)2022 CBC Wind=239 lbs SDC= D EQ*Ω=222 lbs Ω= 2 Load combination used for the design: 0.900 DL +1.0 W (0.9-0.2SDS) if EQ Governs 1 V =239 lbs 1 V x 0.3=72 lbs (orthogonal direction) Hc =5.9 ft.COG =3.0 ft. Dc =0.7 ft.Wc =0.7 ft. Wp =0.9 DL =328 lbs MOT =V x COG MOT =V x COG =707 lb-ft =212 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =109 lb-ft =109 lb-ft M =MOT - MR M =MOT - MR =598 lb-ft =103 lb-ft Anchor Bolts for Power Supply Cabinet Bolt Number =4 T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =448 lbs.=77 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =60 lbs.=18 lbs. V Wp Hc T Dc 18 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Power Supply Page: Specifier: E-Mail: Date: 1 Yoo Jin Kim yokim@tesla.com 5/6/2024 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (3 1/4 ) hnom3 Item number: 2210261 KB-TZ2 1/2x4 1/2 SS304 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2023 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 4.000 in. x 4.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 12.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, ft.lb] 19 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Power Supply Page: Specifier: E-Mail: Date: 2 Yoo Jin Kim yokim@tesla.com 5/6/2024 1.1 Design results Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 525; Vx = 60; Vy = 18; Mx = 0.000; My = 0.000; Mz = 0.000; yes 22 20 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Power Supply Page: Specifier: E-Mail: Date: 3 Yoo Jin Kim yokim@tesla.com 5/6/2024 2 Proof I Utilization (Governing Cases) Design values [lb]Utilization Loading Proof Load Capacity bN / bV [%]Status Tension Concrete Breakout Failure 525 2,428 22 / -OK Shear Concrete edge failure in direction y+63 2,666 - / 3 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.216 0.024 5/3 8 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 21 1312 E Warner Ave 2/10/2025 www.hilti.com Hilti PROFIS Engineering 3.0.94 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Power Supply Page: Specifier: E-Mail: Date: 4 Yoo Jin Kim yokim@tesla.com 5/6/2024 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 22 1312 E Warner Ave 2/10/2025