HomeMy WebLinkAbout1913 W Edinger Ave - 101118671 & 20182410 - PlanCALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO. DATE DESCRIPTION NO. DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 TITLE SHEET SITE ADDRESS: UNITED PACIFIC #5669 1913 W EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/23 5669 TITLE ALVARO CORONA SHEET T1 UNITED PACIFIC #5669 UNDERGROUND STORAGE TANK INSTALLATION (SEE SHEET F-1 FOR SCOPE OF WORK) 1913 W EDINGER AVE. SANTA ANA, CA 92704 T1 DRAWING NAME TITLE SHEET SITE PLAN & SCOPE OF WORK UST INSTALLATION NOTES UST AND SUMP DETAILS DETAILS AND LIST OF EQUIPMENT DRAWING INDEX SHEET # F1 F2 F3-1 F4-2 SITE ELECTRICAL CONDUIT PLANF5 ELECTRICAL NOTESF6 VEEDER ROOT ELECTRICALF7 ELECTRICAL DETAILSF8 B A C D E F G H I J B A C D E F G H I J 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 LICENSED CONTRACTOR STATE OF CALIFORNIA CORONA CONSTRUCTIONCO. 797455 EXPIRES 07/31/2025 GENERAL NOTES SUMMARY: 1. PROVIDE ALL LABOR. MATERIAL EQUIPMENT AND SYSTEMS REQUIRED FOR FULL PERFORMANE AND COMPLETION OF WORK AS SHOWN ON THE DRAWINGS, SPECIFIED HEREIN AND AS REQUIRED FOR THE CONSTRUCTION OF A COMPLETE, OPERATIONAL, SERVEABLE TURN-KEY PROJECT. 2. THESE GENERAL REQUIERMENTS APPLY TO ALL SECTIONS OF THESE SPECIFICATIONS AS IF STATED SEPARATELY IN EACH SECTION. CONSTRUCTION DOCUMENTS: 1. EXAMINE THE CONSTRUCTION DOCUMENTS INCLUDING THESE NOTES, THE DRAWINGS, DETAILS, PERMITS, ALL EQUIPMENT MANUFACTURER SPECIFICATIONS/INSTALLATION INSTRUCTIONS AND BID DOCUMENTS. 2. READ THE SPECIFICATOINS. 3. VISIT THE SITE OF THE WORK. 4. ADDRESS ANY AND ALL QUESTIONS REGARDING THE CONSTRUCTION DOCUMENTS TO THE OWNER FOR INTERPRETATION. 5. BECOME THOROUGHLY ACQUAINTED WITH ALL REQUIREMENTS OF THE PROJECT, EXISTING CONDITIONS, AND LIMITATIONS UNDER WHICH THE WORK SHALL BE EXECUTED, BIDS SHALL REFLECT A SUM TO COVER THE COST OF ALL ITEMS REQUIRED TO PERFORM THE WORK AS SET FORTH IN THE CONSTRUCTION DOCUMENTS. NO ALLOWANCE WILL BE MADE FOR THE LACK OF EXAMINATION OR KNOWLEDGE OF THE PROJECT. SUBMISSION OF A BID SHALL BE CONSIDERED AS CONCLUSIVE EVIDENCE THAT THE BIDDER HAS MADE A THOROUGH EXAMINATION. CHANGE ORDERS FOR DISCREPANCIES ONCE CONSTRUCTION HAS STARTED WILL NOT BE ALLOWED. 6. CONSTRUCTION DOCUMENTS CONSIST OF THE PERMIT SET OF PLANS (DRAWINGS), SPECIFICATIONS AND SUPPLEMENTAL DOCUMENTS ISSUED TO DEFINE THE NATURE AND SCOPE OF THE PROJECT. 7. THESE CONSTRUCTION DOCUMENTS (DRAWINGS AND SPECIFICATIONS) HAVE BEEN PREPARED TO DEFINE THE INSTALLATION OF NEW UNDERGROUND STORAGE TANKS, PIPING AND DISPENSERS. SEE SHEET F1 FOR COMPLETE SCOPE OF WORK. 8. WRITTEN DIMENSIONS AND NOTATIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND DRAWING CONFIGURATIONS. DO NOT SCALE DRAWINGS. 9. WORK NOT DETAILED OR SPECIFIED SHALL BE SAME QUALITY AND TYPE AS WORK DETAILED OR SPECIFIED AS REQUIRED FOR THE CONSTRUCTION OF A COMPLETE AND SERVICEABLE PROJECT. 10. ALL INSTRUCTIONS NOTED IN THE CONSTRUCTION DOCUMENTS ARE ADDRESSED DIRECTLY TO THE GENERAL CONTRACTOR AND ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 11. VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE. 12. REPORT IMMEDIATELY IN WRITING TO THE OWNER ANY AND ALL DISCREPANCIES FOUND OR PERCEIVED TO EXISTING BETWEEN DRAWINGS, SPECIFICATIONS, AND SITE CONDITIONS EITHER EXISTING OR CREATED. 13. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND THE CONTRACTOR SHALL INFORM THE OWNER IN WRITING OF ALL DISCREPANCIES AND DEVIATIONS FROM INFORMATION PRESENTED ON THESE DRAWINGS AND SPECIFICATIONS. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK WILL BE PERFORMED. CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. THE BUILDER AND ALL SUBCONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THESE DOCUMENTS. IT IS THE INTENT OF THESE PLANS THAT THE CONTRACTOR PROVIDE A COMPLETE “TURN-KEY” PROJECT AND THAT NO CHANGE ORDERS WILL BE ISSUED FOR DISCREPANCIES ONCE CONSTRUCTION HAS STARTED. 14. WHERE A DISCREPANCY IS NOTED PRIOR TO BIDDING, THE OWNER SHALL RENDER A DECISION AND ESTABLISH THE PRECEDENCE OF THE INFORMATION IN QUESTION PRIOR TO CONSTRUCTION. 15. MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS, AS-BUILT INSTALLED. CHANGES IN DESIGN, INCLUDING DIMENSIONS AND PHOTOGRAPHS OF ALL UNDERGROUND INSTALLATIONS. 16. RETURN MARKED UP CONSTRUCTION DOCUMENTS, AS-BUILT DOCUMENTS TO THE OWNER AT SUBSTANTIAL COMPLETION. 17. RETURN ALL DRAWINGS AND SPECIFICATIONS FURNISHED BY OWNER AT COMPLETION OF WORK. DRAWINGS AND SPECIFICATIONS ARE OWNERS' PROPERTY AND SHALL BE RETURNED. 18. THE TERM “PRODUCT” INCLUDES MATERIALS, SYSTEMS, AND EQUIPMENT. THE TERM “PROVIDE” INCLUDES FURNISHING AND INSTALLING A PRODUCT, COMPLETE IN PLACE, OPERATING, TESTED, AND APPROVED. THE TERM “BUILDING CODE” AND THE TERM “CODE” REFER TO PUBLISHED REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION. THE TERMS “APPROVED”, “REQUIRED” AND “AS DIRECTED” REFER TO AND INDICATE THE WORK OR MATERIALS THAT MAY BE APPROVED, REQUIRED OR DIRECTED BY THE ARCHITECT ACTING AS THE AGENT OF THE OWNER. THE TERM “SIMILAR”, MEANS IN ITS GENERAL SENSE AND NOT NECESSARILY IDENTICAL. THE TERMS “SHOWN”, “INDICATED”, “NOTED”, “SCHEDULED”, AND TERMS OF SIMILAR IMPORT, REFER TO REQUIREMENTS CONTAINED IN THE CONTRACT DOCUMENTS. 19. COMPLY WITH ALL LAWS, CODES, ORDINANCES AND REGULATIONS WHICH APPLY TO THIS PROJECT. 20. RESOLVE ALL DEVIATIONS BETWEEN DRAWINGS AND SPECIFICATIONS AND ANY LAWS, CODES, ORDINANCES, OR REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION BEFORE INSTALLATION OF WORK IN QUESTION PRIOR TO THE START OF CONSTRUCTION. CONTROL OF SITE: 1. THE SITE WILL BE AVAILABLE TO THE CONTRACTOR SUBSEQUENT TO RECEIPT OF THE OWNER'S WRITTEN NOTICE TO PROCEED. CARE, CUSTODY, AND CONTROL OF THE SITE WITHIN THE LIMITS SET FORTH ON THE DRAWINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR FOR THE DURATION OF THE AGREEMENT. 2. ORGANIZE AND PERFORM WORK SO THAT THE OPERATIONS OF EXISTING FACILITIES AND ADJOINING PROPERTY OWNERS CAN CONTINUE NORMALLY AND WITH A MINIMUM OF INTERRUPTIONS. 3. PROTECT EXISTING CONSTRUCTION IDENTIFIED TO REMAIN INCLUDING, BUT NOT NECESSARILY LIMITED TO EXISTING LANDSCAPING, EARTHWORK, ADJOINING PROPERTY, STREET, ETC... FROM DAMAGE AND GIVE PROPER WRITTEN NOTICE OF PROPOSED WORK TO ADJOINING PROPERTY OWNERS. 4. REPAIR ALL DAMAGE TO ADJOINING PROPERTIES CAUSED BY OPERATIONS OF THIS PROJECT TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE. 5. PROTECT COMPLETED WORK FROM DAMAGE UNTIL ACCEPTED BY OWNER. 6. PROVIDE SITE BARRIERS AND SECURITY FENCING TO ISOLATE THE SITE FORM THE GENERAL PUBLIC AND CONTROL SITE ACCESS AT ALL TIMES. 7. PROVIDE ALL SAFETY SIGNAGE POSTED IN CONSPICUOUS LOCATIONS AS REQUIRED BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION, INCLUDING BUT NOT NECESSARILY LIMITED TO OSHA, U.S. DEPT. OF LABOR, CITY BUILDING DEPARTMENT, LOCAL FIRE AND FOR TRAFFIC CONTROL. 8. PROVIDE DEMOLITION AND CLEAR THE SITE IN COMPLIANCE WITH LOCAL BEST MANAGEMENT PRACTICES. 9. MAINTAIN SITE IN ACCESSIBLE CONDITION FOR ALL SUBCONTRACTORS. ACCESSIBLITY NOTES: 1. WALKS AND SIDEWALKS SUBJECT TO THESE REGULATIONS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY STEPS AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH. 2. SURFACES WITH A SLOPE OF LESS THAN 6 PERCENT GRADIENT SHALL BY AT LEAST AS SLIP-RESISTANT AS THAT DESCRIBED AS A MEDIUM SALTED FINISH. 3. SURFACES WITH A SLOPE OF 6 PERCENT GRADIENT OR GREATER SHALL BE SLIP RESISTAN. 4. SURFACE CROSS SLOPES SHALL NOT EXCEED ¼ INCH PER FOOT. 5. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED ½ INCH. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 EXCEPT THAT LEVEL CHANGES NOT EXCEEDING ¼ INCH MAY BE VERTICAL. 6. ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIES WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS AT INACCESSIBLE, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 7. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 6 FEET, 8 INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY ISN'T LESS THAN 32 INCHES, ALL DOORS SHALL SWING OUTWARD IN THE PATH OF TRAVEL TO EXIT. 8. THE MAXIMUM SLOPE OF ACCESSIBLE PARKING AND PASSENGER LOADING ZONE SURFACE AND ANY DIRECTION SHALL NOT EXCEED 2% PER ADA ACCESSIBILITY STANDARDS. THE MAXIMUM SLOPE AT THE PASSENGER LOADING ZONE SHALL NOT EXCEED 2%. 9. NEW SCOPE OF WORK NOT TO AFFECT EXISTING ACCESSIBLE PATH OF TRAVEL. SEE SHEETS F1 & F5. CODES AND STANDARDS: APPLICALBE CODES, STANDARDS AND SPECIFICATIONS INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. NATIONAL FIRE PROTECTION ASSOCIATION, VOL. 30, “FLAMMABLE AND COMUSTIBLE LIQUIDS CODE”. 2. FEDERAL CODE OF REGULATIONS (CFR), PARTS 280-281 3. CALIFORNIA HEALTH & SAFETY CODE, CHAPTER 6.7. 4. CALIFORNIA CODE OF REGUALTIONS (CCR) TITLE 23 (CALIFORNIA UST REGULATIONS) 5. NATIONAL INSTITUTE FOR OCCUPATIONAL SAFETY AND HEALTH, NIOSH, “WORKING IN CONFINED SPACE”. 6. 7. DEPARTMENT OF TRANSPORTATION REGULATIONS 49 CFR, PARTS 171 THROUGH 180. 8. TITLE 22 CALIFORNIA CODE OF REGULATIONS, DIVISION 4.5, CHAPTER 32, SECTION 67383. 9. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT REGULATIONS - RULES 1166 AND 1149. 10. NATIONAL FIRE PROTECTION ASSOCIATION, NFPA 70, NATIONAL ELECTRICAL CODE, ARTICLES 500 THROUGH 516. 11. ORANGE COUNTY ENVIRONMENTAL DIVISION (CUPA) REQUIREMENTS. 12. REQUIREMENTS OF THE CITY OF SANTA ANA BUILDING AND SAFETY DEPARTMENT. 13. ASTM STANDARD DOCUMENT D4021-92. 14. FACTORY MUTUAL SYSTEMS APPROVAL FOR DOUBLE WALL J.I. IM7A0.AF. 15. THE LATEST EDITION OF THE CALIFORNIA FIRE CODE. 16. THE EQUIPMENT MANUFACTURERS INSTALLATIONS INSTRUCTIONS AND SPECIFICATIONS. 17. CAL OSHA REGULATIONS FOR EXCAVATIONS AND CONFINED SPACE. CAL OSHA PERMIT IS REQUIRED FOR EXCAVATION 5' OR DEEPER. 18. LATEST EDITION OF THE CALIFORNIA BUILDING CODE. 19. CALIFORNIA CODE OF REGULATIONS, TITLE 23, DIVISION 3, CHAPTER 16, UNDERGROUND TANK REGULATIONS. 20. CALIFORNIA HEALTH AND SAFTEY COD, CHAPTER 6.7, UNDERGROUND STORAGE OF HAZARDOUS SUBSTANCES. 21. PEDESTRIAN PROTECTION DURING CONSTRUCTION SHALL BE PROVIDED PER CBC SEC. 3306. 22. DISPENSERS SHALL COMPLY WITH 2013 CBC, CHAPTER 1, SECTION 111B-220.2. QUALITY ASSURANCE AND WARRANTIES: 1. MAINTAIN A COPY OF APPROVED DRAWINGS, CUPA PERMIT AND FIRE PERMIT WITH ADDENDA AT THE JOB SITE DURING ALL CONSTRUCTION ACTIVITIES THROUGH RECEIPT OF FINAL INSPECTION. 2. PROVIDE WRITTEN GUARANTEE AGAINST DEFECTS IN MATERIALS, EQUIPMENT, OR WORKMANSHIP OF THIS CONTRACTOR FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION AS ESTABLISHED BY RECEIPT OF CERTIFICATE OF OCCUPANCY, ITEMS CARRYING MANUFACTURERS' WARRANTEES OF LONGER DURATION SHALL COMMENCE CONCURRENT WITH THE CONTRACTORS GUARANTEE. 3. PROVIDE MATERIALS AND EQUIPMENT OF BRANDS AND GRADES WHICH ARE SPECIFIED AND INCLUDED TO ESTABLISH TYPE AND QUALITY REQUIREMENT. THESE BRANDS AND GRADES SHALL BE APPROVED BY THE OWNER AS SPECIFIED. 4. IT IS THE RESPONSIBILITY OF THE PARTY REQUESTING SUBSTITUTION TO PROVIDE PRODUCTS REPRESENTED AS EQUAL WITH DOCUMENTATION OF EQUALITY. 5. PROVIDE QUALIFIED, RESPONSIBLE REPRESENTATIVE ON SITE AT ALL TIMES THROUGH SUBSTANTIAL COMPLETION, WHO UNDERSTANDS, SPEAKS, AND WRITES ENGLISH FLUENTLY. 6. UTILIZE ADEQUATE NUMBERS OF SKILLED PERSONNEL WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK OF THIS SECTION. 7. PROVIDE WORKMANSHIP OF GOOD QUALITY, ACCEPTABLE TO THE OWNER OR THE OWNER'S REPRESENTATIVE AND MEETING THE “INDUSTRY STANDARD” FOR THE TYPE OF WORK SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. 8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION LAYOUT AND SCHEDULING, AND COORDINATING ALL PORTIONS OF THE WORK, AND SHALL REQUIRE HIS SUBCONTRACTORS TO PROMPTLY NOTIFY HIM OF THEIR LAYOUT AND SCHEDULING NEEDS. 9. EMPLOY SKILLED PERSONNEL TO PERFORM BUILDING LAYOUT INCLUDING OVERALL WIDTH, LENGTH, AND HEIGHT AND SUCH SPECIFIC GRADES, LINES, AND LEVELS AS SHOWN ON THE PROJECT DOCUMENTS. 10. ESTABLISH AND MAINTAIN ALL LINES, LEVELS, AND GRADES SHOWN ON DRAWINGS OR OTHERWISE REQUIRED. 11. ELEVATIONS NOTED ARE REFERENCED TO BENCHMARKS SHOWN ON BUILDING PLANS. 12. COORDINATE THE SCHEDULING OF ALL INSTALLATIONS TO FACILITATE THE TIMELY PROCESS OF THE WORK WITHOUT REMOVAL OF ANY INSTALLED CONSTRUCTION. TESTING, SAFETY AND INSPECTIONS: 1. PROVIDE TESTS AND/OR INSPECTIONS AS SPECIFIED ON THE DRAWINGS AND SPECIFICATIONS AND AS MAY ADDITIONALLY BE REQUIRED DURING THE COURSE OF CONSTRUCTION. 2. PROVIDE TESTING BY A RECOGNIZED REPUTABLE TESTING AGENCY. 3. MAKE SUBMITTALS OF ALL MATERIAL SAFTEY DATA SHEETS (MSD'S) FOR ALL MATERIALS AND PRODUCTS IN OR ON THIS PROJECT. 4. SUBMITTALS SHALL BE MADE FOR AS MANY MATERIALS AS POSSIBLE BEFORE THE START OF THE WORK. 5. MAINTAIN A COMPLETE THREE RING BINDER AT THE JOB SITE CONTAINING MANUFACTURER INSTALLATION, OPERATION, AND MAINTENANCE MANUALS. BINDER SHALL BE PROVIDED TO THE OWNER AT COMPLETION OF THE PROJECT. 6. MAKE THE BINDER AVAILABLE TO ALL WORKERS, SAFETY PERSONNEL, INSPECTORS, SUBCONTRACTORS AND THE OWNER. 7. CONDUCT REGULAR SAFETY MEETINGS AND DISCUSS WITH PERSONNEL THE SPECIFICS RELATIVE TO ALL ON GOING MATERIALS AND PRODUCT USAGE. 8. SCAQMD TESTING SHALL BE PROVIDED IN ACCORDANCE WITH EXECUTIVE ORDER VR-204-Q. 9. PROVIDE SB-989 TESTING AND PROVIDE A NEW MONITORING SYSTEM CERTIFICATION PRIOR TO FINAL INSPECTION. MATERIALS AND EQUIPMENT: 1. COORDINATE AND EXPEDITE PROCUREMENT OF MATERIALS AND EQUIPMENT. 2. STORE MATERIALS BLOCKED OR ON PLATFORMS ABOVE GROUND AND STORE IN A MANNER THAT WILL PROTECT UNITS FROM CONTACT WITH SOIL AND EXPOSURE TO WEATHER. 3. EXERCISE CARE IN HANDLING MATERIALS AND OPERATION OF EQUIPMENT TO PREVENT DAMAGE. 4. LOCATE STORAGE AREAS WHERE THEY WILL NOT BE DISTURBED OR DAMAGED BY CONSTRUCTION OPERATIONS. 5. STOCKPILE MATERIALS SUFFICIENTLY IN ADVANCE OF NEED TO ASSURE THEIR AVAILABILITY IN A TIMELY MANNER FOR THIS WORK. 6. MAKE AS MANY TRIPS TO THE JOB SITE AS ARE NEEDED TO DELIVER MATERIALS FOR THIS PROJECT IN A TIMELY MANNER TO ENSURE ORDERLY PROGRESS OF THE WORK. 7. DO NOT PERMIT MATERIALS NOT COMPLYING WITH THE PROVISIONS OF THESE SPECIFICATIONS TO BE BROUGHT ONTO OR TO BE STORED AT THE JOB SITE. 8. REMOVE PROMPLTY NON-COMPLYING MATERIALS FROM THE JOB SITE AND REPLACE WITH MATERIALS MEETING THE REQUIREMENTS OF THIS SECTION. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE SECURE, LOCKABLE STORAGE FOR ALL CONSTRUCTION MATERIALS AND EQUIPMENT. REPLACEMENT AFTER RECEIPT SHALL BE BY THE CONTRACTOR. 10. THE CONTRACTOR SHALL TAKE RECEIPT OF ALL OWNER SUPPLIED EQUIPMENT, CONFIRM MADEL AND QUANTITY AND NOTIFY OWNER OF ANY DISCREPANCIES. CLEAN UP AND ADJUSTMENT: 1. CLEAN ALL AREAS OF THE FACILITY AFFECTED BY THE PROJECT. 2. REMOVE ALL DEBRIS AND LEAVE PREMISES BROOM CLEAN. 3. CLEAN AND POLSIH ALL GLASS AND PLUMBING, INCLUDING FIXTURES. 4. WIPE CLEAN AND POLISH FACILITY EQUIPMENT (PUMPS/DISPENSERS, SIGNS, SHELVING, COOLERS, LIGHTS, AND NEW EQUIPMENT IN CONSTRUCTION DISTRUVED AREAS, ETC.). 5. EXERCISE CAUTION TO AVOID DAMAGING OR STAINING PAINT, CONCRETE, TILE, ETC. 6. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTIONG ALL DAMAGE UP TO SUBSTANTIAL COMPLETION. DETAILS AND LIST OF EQUIPMENTF4-1 F3-2 UST AND SUMP DETAILS ELECTRICAL DETAILSF9 1 5/14/24 UPDATED DRAWING INDEX. ADDED CAL OSHA NOTE. 1 1 SIGNED 5/14/24 1 1 ADDED DISABLED ACCESS COMPLIANCE DOCUMENT SHORING DETAILSF10 Bldg# 101118671 Elec# 20182410 APPROVALS: PLNG - ASevilla BLDG - CSG Consultant ELEC - CSG Consultant 1913 W Edinger Ave - 101118671 & 201824107/2/2024 NO PARKING CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 SITE PLAN & SCOPE OF WORK SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F1 ALVARO CORONA SHEET F1 1 SETUP SAFETY BARRICADES AND FENCE. EXCAVATE AS NEEDED FOR NEW TANKS AND PIPING. BACKFILL TANK EXCAVATION TO TOP OF TANK WITH APPROVED BACKFILL MATERIAL. ITEM 2 3 DRESS TRENCH EXCAVATION WITH APPROVED BACKFILL MATERIAL. INSTALL NEW DOUBLE WALL FIBERGLASS SUMP RISERS ON TANK COLLARS PER MANUFACTURER SPECIFICATIONS. INSTALL NEW BRAVO DOUBLE WALL UNDER DISPENSER CONTAINMENT SUMPS AT ALL DISPENSER LOCATIONS. INSTALL NEW DOUBLE WALL BRAVO VENT TRANSITION SUMP (SEE DETAIL E ON SHEET F4) B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 DESCRIPTION PROVIDE OSHA SHIRED TANK HOLE. PREPARE EXCAVATION WITH FILTER FABRIC LINER AND APPROVED TANK BED MATERIAL PER MANUFACTURER SPECIFICATIONS (SEE SHEET F3). 4 INSTALL (3) NEW 12K GALLON XERXES DOUBLE WALL FIBERGLASS UNDERGROUND STORAGE TANKS PER THE MANUFACTURERS INSTALLATION SPECIFICATIONS (SEE SHEET F3 FOR DETAILS). 5 6 7 8 9 10 INSTALL NEW DOUBLE WALL PRODUCT, VENT AND VAPOR PIPING PER MANUFACTURER SPECIFICATIONS. PROVIDE PRESSURE TESTING AND INSPECTION OF PRIMARY AND SECONDARY PIPING SYSTEMS. INSTALL NEW TANK TOP EQUIPMENT (SEE DETAILS C & D ON SHEET F3). INSTALL NEW UNDER DISPENSER CONTAINMENT EQUIPMENT (SEE SHEET F4). INSTALL VENT TRANSITION SUMP EQUIPMENT (SEE DETAIL E ON SHEET F4). 11 12 13 14 INSTALL NEW RAISED CONCRETE ISLANDS AND BOLLARDS. INSTALL NEW ELECTRICAL CONDUITS TO INSIDE TANK SUMPS, VENT SUMP AND TO UDC ELECTRICAL OFFSET AREAS. 15 16 19 PROVIDE HYDROSTATIC TESTING AND INSPECTION OF NEW TANK SUMPS, UNDER DISPENSER CONTAINMENT SUMPS AND NEW VENT TRANSITION SUMP. PROVIDE HELIUM (OR OTHER APPROVED) ENHANCED LEAK DETECTION PRE-TESTING. 17 18 INSTALL ELECTRICAL CONDUITS, FITTINGS, J-BOXES, SEALS AND CONDUCTORS. INSTALL NEW VEEDER ROOT TLS-350 PANEL. INSTALL TURBINE CONTROLLER AND NEW BREAKERS AT FUEL SYSTEM ELECTRICAL PANEL (SEE SHEET F8). INSTALL NEW STEEL VENT RISERS AND VAPOR SYSTEM MANIFOLD – USE EXISTING HEALY TANK.20 22 21 PROVIDE INSPECTIONS (ELECTRICAL, FIRE, AIR QUALITY AND DEH) AND BACKFILL EXCAVATIONS WITH APPROVED BACKFILL MATERIAL TO SUB CONCRETE GRADE - SET STEEL MANWAYS. CONNECT AND TEST ELECTRICAL AND FUEL SYSTEM PIPING CONNECTIONS.23 24 PLACE AND FINISH CONCRETE AT NEW TANK SLAB AND DRIVE SLABS.25 COORDINATE FUEL DROP – PRIME AND PURGE FUEL SYSTEM PIPING.26 CALIBRATE, PROGRAM, TEST FOR FUEL SYSTEM PROPER OPERATION AND CERTIFY ALL FUEL SYSTEM COMPONENTS.27 PROVIDE ENHANCED LEAK DETECTION TESTING PER ORANGE COUNTY ENVIRONMENTAL HEALTH.28 INSTALL NEW DISPENSER DECALS AND FUEL SYSTEM SIGNAGE.29 PROVIDE FINAL INSPECTIONS AND DEMONSTRATE FUEL SYSTEM OPERATION.30 REMOVE CONSTRUCTION DEBRIS AND CLEAN SITE.31 32 33 34 35 36 37 38 39 40 41 NOTE:TANK ANNULARS, SUMP RISERS, UNDER DISPERNSER CONTAINMENT SUMPS AND VENT TRANSITION SUMP ARE HYDROSTATICALLY MONITORED. SCOPE OF WORK VAPOR RETURN LINE – 4”/3” PART 91 UL PRODUCT PIPE – 3”/2” 91 UL VENT PIPE – 3”/2” LINE LENGTH 2 91 UL VAC TUBE CONDUIT BETWEEN SUMPS – 3”/2” 87 UL PRODUCT PIPE – 3”/2” 87 UL VENT PIPE – 3”/2” 87 UL VAC TUBE CONDUIT BETWEEN SUMPS – 3”/2” VAPOR RETURN LINE – 3”/2” PART VACUUM ZONE TABLE SS MODULE CHANNEL 7 8 9 3 4 6 VAC SENSOR MONITORED ZONE 30' 210’ 175’ 110’ 30’ 190’ 100' 30' VOL. GAL/FT 0.23 GAL/FT 0.276 GAL/FT 0.23 GAL/FT 0.23 GAL/FT 0.23 GAL/FT 0.23 GAL/FT 0.23 GAL/FT 0.23 GAL/FT CALCULATED ZONE VOLUME 6.9 GAL. 58 GAL. 40.25 GAL. 25.3 GAL. 6.9 GAL. 437 GAL. 23 GAL. 6.9 GAL. THE WORK, IN GENERAL, IS THE INSTALLATION OF NEW UNDERGROUND STORAGE TANKS, NEW FUEL SYSTEM PIPING AND NEW FUEL DISPENSERS AS FOLLOWS: 1 10 11 12 DIESEL UL PRODUCT PIPE – 3”/2” DIESEL UL VENT PIPE – 3”/2” DIESEL UL VAC TUBE CONDUIT BETWEEN SUMPS – 3”/2” 200’ 90' 30’ 0.23 GAL/FT 0.23 GAL/FT 0.23 GAL/FT 46 GAL. 20.7 GAL. 6.9 GAL. SITE PLAN SCALE: 3/32" = 1' - 0" 0'5'10'20' GRAPHIC SCALE NORTH 2A:20BC FIRE EXTINGUISHERS (2 LOCATIONS) COLUMN, CANOPY SUPPORTS EXISTING IMPACT PROTECTORS ( 6 LOCATIONS) S R A I T T S T . (E) DIESEL 12K PLANTER W EDINGER AVE. (E) 87 12K (E) 91 12K 12 10 11 9 8 6 7 5 4 2 3 1 PLANTER PLANTER BUILDING EXISTING TRASH ENCLOSURE INSTALL 5 NEW GILBARCO ENCORE 700 3+0 AND (1) GILBARCO ENCORE 700 3+1 DISPENSERS (BLENDING GASOLINE). INSTALL NEW DISPENSER HOSES, NOZZLES AND BREAKAWAYS – (SEE DETAIL G ON SHEET F4). EXISTING REMEDIATION COMPOUND CANOPY COLUMN EXISTING HEALY TANK NEW VENTS NEW VENT BOX CROSS OVER EXISTING ACCESSIBLE PATH OF TRAVEL EXISTING ACCESSIBLE PATH OF TRAVEL SCOPE OF WORK NOT TO AFFECT EXISTING ACCESSIBLE PATH OF TRAVEL 1 5/14/24 NOTED EXISTING ACCESSIBLE PATH OF TRAVEL SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 UST INSTALLATION NOTES SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F2 ALVARO CORONA SHEET F2 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 TANK AND PIPING INSTALLATION NOTES MATERIAL AND WORKMANSHIP 1.UNLESS OTHERWISE SPECIFICALLY PROVIDED IN THESE DOCUMENTS, ALL EQUIPMENT, MATERIAL, AND ARTICLES INCORPORATED IN THE WORK COVERED BY THESE DOCUMENTS ARE TO BE NEW AND OF THE MOST SUITABLE GRADE FOR THE PROCESS INTENDED. CONTRACTOR SHALL NOT DEVIATE FROM MATERIALS OR PRODUCTS SPECIFIED UNLESS THROUGH MUTUAL AGREEMENT WITH THE OWNER'S CONSTRUCTION MANAGER APPROVAL MUST BE IN WRITING, SIGNED BY OWNER'S CONSTRUCTION MANAGER SUBSTITUTE MATERIALS SHALL BE DESCRIBED, SPECIFYING ANY DIFFERENCE IN COST AND PERFORMANCE. ONLY NEW MATERIALS SHALL BE USED. CONTRACTOR SHALL BE CERTIFIED FOR THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS CONTAINED IN THIS PROJECT. 3.THE CONTRACTOR SHALL FURNISH TO THE OWNER'S REPRESENTATIVE FOR HIS APPROVAL, THE NAME OF THE MANUFACTURER, THE MODEL NUMBER, AND OTHER IDENTIFYING DATA AND INFORMATION RESPECTING THE PERFORMANCE, CAPABILITY, NATURE, AND RATING OF THE MACHINERY, MECHANICAL AND OTHER EQUIPMENT, MATERIAL OR ARTICLES WHICH THE CONTRACTOR CONTEMPLATES INCORPORATING IN THE WORK WHEN REQUIRED BY THE OWNER'S REPRESENTATIVE. 4.MACHINERY, EQUIPMENT, MATERIAL, AND ARTICLES INSTALLED OR USED WITHOUT REQUIRED WRITTEN APPROVAL SHALL BE AT THE RISK OF SUBSEQUENT REJECTION. 5.CONTRACTOR TO PROVIDE ALL MATERIALS NOT LISTED ON THE OWNER'S SUPPLIED EQUIPMENT LIST, BUT REQUIRED FOR A COMPLETE AND OPERATING FUEL STORAGE AND DISPENSING SYSTEM. 6.CONTRACTOR IS RESPONSIBLE FOR COORDINATING, RECEIVING AND UNLOADING THE ENTIRE OWNER'S SUPPLIED EQUIPMENT DELIVERED TO CONTRACTORS WAREHOUSE, OR JOB SITE. THE SECURING OF EQUIPMENT REMAINS THE CONTRACTOR'S RESPONSIBILITY UNTIL THE PROJECT RETAINAGE IS PAID. CONTRACTOR TO DISTRIBUTE ALL RECEIVING DOCUMENTS TO THE OWNER'S CONSTRUCTION MANAGER. 7.ALL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. 8.ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS AND THESE DOCUMENTS. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 9.IF ANY OF THESE DOCUMENTS INDICATE A CONFLICT WITH THE STATE OR LOCAL REQUIREMENTS AS ARE CURRENTLY IN EFFECT AT THE TIME OF THIS PROJECT, IT IS EXPECTED THAT THE MOST RESTRICTIVE CONDITION(S) WOULD APPLY. GENERAL CONDITIONS 1.CONTRACTOR EMPLOYEES SHALL HAVE COMPLETED 40 HOURS OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA) TRAINING COURSE PRIOR TO THE START OF WORK CERTIFICATION OF THIS MUST BE PROVIDED TO THE OWNER'S REPRESENTATIVE PRIOR TO THE START OF WORK. 2.CONTRACTOR EMPLOYEES SHALL HAVE COMPLETED THE EQUIPMENT (INCLUDING, BUT NOT LIMITED TO, TANK, PIPING, SUMPS, DISPENSERS, MONITORING) MANUFACTURER'S TRAINING REQUIREMENTS IN ACCORDANCE WITH, BUT NOT LIMITED TO, CALIFORNIA UNDERGROUND STORAGE TANK (UST) REGULATIONS AND CALIFORNIA AIR RESOURCES BOARD (CARB) REQUIREMENTS. CERTIFICATES SHALL BE PROVIDED TO OWNER. CONTRACTOR SHALL COMPLETE THE INSTALLATION CHECKLISTS SUPPLIED BY MANUFACTURERS AND SHALL FURNISH THE CHECKLISTS TO OWNER. 3.CONTRACTOR SHALL HAVE THE FOLLOWING LICENSES: A:GENERAL ENGINEERING (A) B:HAZARDOUS MATERIAL SUBSTANCE HANDLING (HAZ) 4.CONTRACTOR SHALL HAVE THE FOLLOWING INSURANCE. CONTRACTOR SHALL HAVE PROOF OF SUCH INSURANCE ON FILE WITH OWNER BY NAMING OWNER AS "ADDITIONAL INSURED." A:STATUTORY WORKMAN'S COMPREHENSIVE LIABILITY B:COMPREHENSIVE GENERAL LIABILITY, WITH A COMBINED SINGLE LIMIT OF NOT LESS THAN $1,000,000 PER OCCURRENCE FOR BODILY INJURY AND PROPERTY DAMAGE. C:AUTOMOBILE LIABILITY COVERING USE OF ALL OWNED OR HIRED VEHICLES WITH A COMBINED SINGLE LIMIT OF LIABILITY OF NOT LESS THAN $1,000,000 PER OCCURRENCE FOR BODILY INJURY AND PROPERTY DAMAGE. 5.CONTRACTOR TO FURNISH ALL LABOR, MATERIAL, EQUIPMENT, AND SERVICES NECESSARY FOR OR REASONABLY INCIDENTAL TO THE SATISFACTORY COMPLETION OF ALL WORK SHOWN ON, CALLED FOR OR REQUIRED BY THE DRAWINGS, EXCEPT AS NOTED AS SUPPLIED BY OWNER OR OTHERS. 6.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CALIF. BUILDING CODE, CALIFORNIA FIRE CODE, CALIF. ELECTRICAL CODE. CALIF. UNDERGROUND STORAGE TANK REGULATIONS. OSHA CONSTRUCTION SAFETY ORDERS, NATIONAL FIRE PROTECTION ASSOC. (NFPA), UNDERWRITER'S LABORATORIES, INC. (UL), CARB EXECUTIVE ORDERS AND GUIDANCE LETTERS AND ANY OTHER APPLICABLE STANDARD OR STATE REGULATION, COUNTY OR CITY ORDINANCES. 7.All PETROLEUM PERMITS TO BE SECURED BY OWNER OR OWNER'S AGENT AND SUPPLIED TO THE CONTRACTOR WHO IS RESPONSIBLE FOR COMPLYING WITH All PERMIT CONDITIONS. CONTRACTOR SHALL SECURE MISCELLANEOUS ELECTRICAL PERMIT UNLESS WORK IS COVERED BY OTHER BUILDING PERMITS FOR THE PROJECT. 8.CONTRACTOR SHALL VISIT SITE AND FAMILIARIZE HIMSELF OF ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. 9.CONTRACTOR SHALL PROTECT ALL EXISTING FACILITIES TO REMAIN UNLESS NOTED OTHERWISE. CONTRACTOR SHALL REPAIR OR REPLACE TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE ANY EXISTING FACILITIES THAT ARE DAMAGED BV THE CONTRACTOR'S OPERATIONS. 10.CONTRACTOR SHALL KEEP THE SITE FREE OF WASTE AND RUBBISH AT ALL TIMES CONTRACTOR SHALL HAVE THE WORK AREA PROFESSIONALLY CLEANED THE DAY BEFORE THE OWNER'S FINAL PROJECT INSPECTION. 11.WHEN AN INSTALLATION IS MADE AT AN EXISTING STORE, THE CONTRACTOR IS TO SCHEDULE ANO PERFORM HIS WORK SO AS NOT TO INTERFERE WITH THE NORMAL STORE OPERATIONS. ALL DEBRIS, EXCESS EXCAVATION MATERIALS, MACHINERY AND EQUIPMENT TO BE REMOVED AND MAINTAINED CLEAR OF THE DRIVEWAYS THAT ARE IN USE EACH DAY & LIGHTED BARRICADES SHALL BE PROVIDED FOR THE PUBLIC'S PROTECTION. WHEN IT BECOMES NECESSARY TO CLOSE A DRIVEWAY FOR MORE THAN 24 HOURS, THE CONTRACTOR Will PROVIDE TEMPORARY TRAVEL SERVICE FOR TRAFFIC. 12.A COPY OF THE SPECIFICATIONS AND DRAWINGS, 4.LONG WITH APPROVED SITE PLAN, WITH AS-BUILT NOTATIONS, SHALL BE ON SITE AT ALL TIMES. 13.CONTRACTOR 1S RESPONSIBLE FOR ANY PRODUCT IN TANKS AND IN LINES UNTIL LOCATION OPENS OR REOPENS FOR GASOLINE BUSINESS. ANY PRODUCT LOSS DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. PA/QA TO PROJECT ACCEPTANCE, THE OWNER SHALL RECONCILE INVENTORY BY COMPARING PRODUCT IN TANKS AND LINES TO AMOUNT DELIVERED SHORTAGES SHALL BE BILLED TO CONTRACTOR AT FULL RETAIL PRICE. 14.CONTRACTOR MUST PROVIDE ADEQUATE PROVISIONS TO MITIGATE RA.IN DAMAGE AND DELAYS (I E. PUMPS. TARPS. ETC.) 15.UPON COMPLETION OF PROJECT, CONTRACTOR SHALL PROVIDE OWNER WITH "AS-BUILT" DRAWINGS OF ALL ITEMS INSTALLED BY SAME. “AS-BUILT” SHALL BE COMPLETED ON-SITE WITH INFORMATION NOTED DIRECTLY ON APPROVED JOB COPY. 16.CONTRACTOR TO WARRANTY ALL WORKMANSHIP AND CONTRACTOR SUPPLIED MATERIAL FOR 1 YEAR THE OWNER SHALL PERFORM A 10 MONTH WARRANTY INSPECTION TO EVALUATE CONTRACTOR PERFORMANCE ANO QUALITY OF WORKMANSHIP. CONTRACTOR MUST COMPLETE ALL PUNCH LIST ITEMS IDENTIFIED DURING THIS 10 MONTH INSPECTION. 17.CONTRACTOR SHALL PROVIDE A LIST OF SUB-CONTRACTORS. IF ANY, WHO WILL BE USED ON THE PROJECT, IF REQUIRED. 18.CONTRACTOR IS TO SCHEDULE ALL SUBCONTRACTORS, INCLUDING THOSE CONTRACTED .DIRECTLY WITH THE OWNER'S CONSTRUCTION MANAGER. THE OWNER WILL PROVIDE A LIST OF SUBCONTRACTORS, CONTACTS AND PHONE NUMBERS FOR THOSE SUBCONTRACTORS THAT HAVE CONTRACTS DIRECTLY WITH THE OWNER. 19.CONTRACTOR SHALL COORDINATE ALL INSPECTIONS AND APPROVALS AND OBTAIN, AT THE COMPLETION OF THE PROJECT, ALL CERTIFICATES REQUIRED TO RUN THE FACILITY. 20.CONTRACTOR SHALL PLACE THE HIGHEST PRIORITY ON SAFETY AND HEALTH DURING THE PROGRESS OF WORK PERFORMED AT THE OWNER'S STORE LOCATIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND MAINTAIN A SAFE WORKING ENVIRONMENT FOR ITS EMPLOYEES DURING THE PROGRESS OF WORK AND TO PROTECT THE HEALTH AND SAFETY OF CONTRACTOR'S AGENTS, SUBCONTRACTORS, THE PUBLIC AND ANY THIRD PARTIES. ALL TOOLS, MATERIALS, EQUIPMENT, FACILITIES AND OTHER ITEMS USED BY THE CONTRACTOR AND PRACTICES EMPLOYED BY THE CONTRACTOR IN ACCOMPLISHING THE WORK ARE CONSIDERED TO BE PART OF THE WORKING ENVIRONMENT, 21.CONTRACTOR TO KEEP ON SITE MATERIAL SAFETY DATA SHEETS (MSOS) FOR CHEMICAL COMPOUNDS REGULATED THROUGH USEPA THAT WILL BE USED ON-SITE OR HAS THE POTENTIAL FOR HUMAN CONTACT (I.E. GASOLINE, DAY ICE, SOLVENTS.GLUES.ETC) 22.WHILE ON SITE AND DURING WORKING HOURS, CONTRACTOR'S PERSONNEL MUST WEAR SHIRTS, LONG PANTS, HARD HATS WHEN REQUIRED, AND ACCEPTABLE FOOT WEAR PER OSHA REGULATIONS. 23.CONTRACTOR TO DEVELOP A SPECIFIC SITE SAFETY PLAN FOR TANK AND EQUIPMENT INSTALLATION PRIOR TO THE START OF WORK, CONTRACTOR WILL CONDUCT WEEKLY JOB SITE SAFETY MEETINGS WITH ITS EMPLOYEES AND THE MEETING MINUTES WILL BE SUPPLIED TO OWNER. D: STEEL PIPE: ALL METAL PIPING SHALL BE BLACK IRON SCHEDULE 40, OR EXTRA STRONG GALVANIZED PIPE IS NOT ALLOWED. FITTING SHALL SE 300 PSI MALLEABLE IRON. ALL STEEL PIPE BELOW GRADE IS TO BE DOUBLE WRAPPED WITH 20 MIL PVC PIPE WRAP, OVER A PIPE WRAP PRIMER FOR USE WITH VINYL TAPES, AND SHALL BE BY THE SAME MANUFACTURER AS THE WRAP. E: ALL THREADED CONNECTIONS SHALL BE THREADED WITH SEALANT WHICH SHALL BE CURRENTLY WARRANTED BY MANUFACTURER FOR FULL COMPATIBILITY WITH THE PIPING MATERIAL USED, AND FOR USE WITH PETROLEUM SOLVENTS, FUELS, OILS, DIESEL, AND 100 % METHANOL, WHICH SHALL BE VERIFIED BY CURRENT MANUFACTURER'S PRODUCT DATA SHEET. F: CONTRACTOR SHALL DEMONSTRATE TO OWNER'S REPRESENTATIVE THAT ALL MATERIALS ARE NEW AND CONFORM TO ABOVE SPECS, IF REQUIRED. 19.DO NOT PLACE PRODUCT PIPING UNDER BUILDINGS. PIPING RUNS OVER TANKS SHALL BE MINIMIZED. MAINTAIN MINIMUM CLEARANCE AS REQUIRED BY MANUFACTURER MINIMIZED CROSSING OTHER LINES AND CONDUIT. IF PIPING IS NOT SHOWN ON SITE PLAN, CONTRACTOR SHALL RUN LINES THE MOST DIRECT ROUTE SUBJECT TO APPROVAL BY OWNER'S REPRESENTATIVE. 20.PROVIDE AND INSTALL CONDUIT & WIRING FOR PETROLEUM SYSTEM(S) AS INDICATED. 21.All CONDUIT IS TO BE ¾” (MINIMUM). 22.INSTALL NEW MONITORING COMPONENTS, AS REQUIRED. PER DRAWINGS AND EQUIPMENT LIST. 23.INSTALL DISPENSERS AND MISCELLANEOUS PETROLEUM SYSTEMS, AS INDICATED ON PLANS AND DESCRIBED IN THE EQUIPMENT LIST. 24.INSTALL NEW CONCRETE TANK AND DRIVE SLABS AND OTHER FUELING SYSTEM CONCRETE AS INDICATED ON SITE PLAN. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI. CONCRETE DESIGN SHALL OTHERWISE COMPLY WITH CIVIL/ARCH DRAWINGS DOCUMENTS. GC SHALL COORDINATE CONCRETE SLABS WORK W/ PETROLEUM CONTRACTOR OR PETROLEUM SUBCONTRACTOR. DISPENSERS PURGE THE AIR FROM THE PIPING SYSTEM USING INDUSTRY STANDARD PRACTICES AND A GROUNDED CONTAINER APPROVED FOR STORAGE AND HANDLING CLASS I FLAMMABLE LIQUIDS. 2.DISPENSERS SHALL BE SECURELY ATTACHED TO ANCHOR BOLTS WHICH SHALL BE SET IN CONCRETE ISLANDS. EXPANSION BOLTS MAY ONLY BE USED WITH THE WRITTEN APPROVAL OF THE OWNER'S CONSTRUCTION MANAGER. QUANTITY AND SIZE OF ANCHOR BOLTS SHALL BE AS SPECIFIED IN DISPENSER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE DISPENSERS ARE TO BE INSTALLED LEVEL AND ARE TO BE CAULKED WITH A GRAY SILICONE AT ISLAND/DISPENSER INTERFACE. 3.DISPENSERS SHALL BE ACTIVATED ONLY IN PRESENCE OF AN AUTHORIZED DISPENSER REPRESENTATIVE. CONTRACTOR HAS SOLE RESPONSIBILITY FOR DAMAGE TO DISPENSER(S) IF THIS INSTRUCTION IS NOT FOLLOWED. 4.CONFIRM DISPENSER OPERATIONS (STP ISOLATION, BRAND PANELS, DECALS AND NOZZLES MATCH, ETC.) IF MISCONNECTIONS OR OTHER PROBLEMS ARE DETECTED DURING CONFIRMATION OF DISPENSER OPERATIONS MAKE CORRECTIONS AND REPEAT DISPENSER CHEACK-OUT PROCEDURE. 5.CALIBRATE AND SEAL METERS PER LOCAL REGULATIONS. ANY RE-CALIBRATION REQUIRED TO OBTAIN APPROVAL FROM LOCAL REGULATORS SHALL BE CONTRACTOR'S RESPONSIBILITY. 6.CONTRACTOR TO FURNISH AND INSTALL NEW DISPENSER FILTERS AFTER COMPLETING ALL LIQUID TESTING AND PRODUCT LINE PURGING. ACTIVATE EACH PRODUCT ON EACH DISPENSER AND INSPECT FILTER FOR LEAKS, RECHECK PRIMARY LINE CONNECTIONS AT DISPENSER BASE AND STOP FOR LEAKS. 7.CONTRACTOR SHALL PERFORM START-UP IF APPROVED BY THE DISPENSER/POS MANUFACTURER. IF CONTRACTOR IS NOT APPROVED BY THE DISPENSER/POS MANUFACTURER, THEN AN AUTHORIZED CONTRACTOR SHALL BE SUBCONTRACTED TO PERFORM START-UP. CONTRACTOR SHALL ALSO PROVIDE AN AUTHORIZED SERVICE TECHNICIAN TO PROVIDE UP TO 8 HOURS OF ON-SITE TRAINING FOR STORE PERSONNEL. CONTRACTOR IS RESPONSIBLE FOR START-UP AND CALIBRATION OF FUELING SYSTEMS. COST MUST BE INCLUDED IN CONTRACTOR'S BASE BID. 8.CONTRACTOR SHALL PROVIDE AND INSTALL PUMP NUMBERS, OCTANE DECALS. NO SMOKING DECALS AND EMERGENCY SHUT-OFF SIGNS, PER THE OWNER'S IMAGE GUIDELINES AND ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL INSTALL ALL OWNER PROVIDED DECALS, PUMP TOPPERS AND WINDSHIELD CADDIES/TRASH CANS PRIOR TO FINAL PROJECT ACCEPTANCE. 9.CONTRACTOR TO FURNISH AND INSTALL FIRE EXTINGUISHERS AND APPROPRIATE DECALS PER APPLICABLE REGULATIONS. TESTING 1.OWNER'S REPRESENTATIVE SHALL WITNESS ALL TESTING AT HIS/HER DISCRETION. CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE TWO DAYS PRIOR TO ANY TESTING, IN WRITING. 2.ALL TESTING SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND REQUIREMENTS, TRADE STANDARDS AND GOVERNING RULES AND CODES, INCLUDING THE USE OF CERTIFIED AND APPROVED INDEPENDENT THIRD PARTY TESTERS, WHEN REQUIRED. 3.FINAL TESTING SHALL BE CONDUCTED BY A THIRD PARTY TESTING COMPANY SUBCONTRACTED TO THE CONTRACTOR TESTING METHODS MUST BE APPROVED BY THE OWNER'S CONSTRUCTION MANAGEMENT AND CONFORM TO ALL REGULATIONS AND CODES. CONTRACTOR SHALL SCHEDULE AND COORDINATE THE TESTING CONTRACTOR ALONG WITH ANY LOCAL INSPECTIONS REQUIRED TO OPEN THE STORE. CONTRACTOR SHALL HAVE A REPRESENTATIVE ON-SITE DURING ALL TESTING. 4.ANY COSTS ASSOCIATED WITH FAILED TESTS AND SUBSEQUENT REPAIRS/RE-TESTS WILL BE THE CONTRACTOR'S RESPONSIBILITY. CONTRACTOR MUST USE AND PAY THE OWNER'S TESTING COMPANY FOR ANY RE-TESTS. 5.CONTRACTOR MUST OBTAIN A COPY OF ALL TEST REPORTS FROM TESTING COMPANY TO BE SUBMITTED WITH THE PROJECT CLOSE OUT REQUIREMENTS. 6.FULLY TEST ALL SYSTEMS, AND REPAIR AS NECESSARY SECURE ALL REQUIRED TESTS, INSPECTIONS, AND APPROVALS OF THE COMPLETED SYSTEM. MAKE ALL REQUIRED ADJUSTMENTS AND CORRECTIONS. DO NOT BACKFILL TRENCHES OR TANK TOP UNTIL AUTHORIZED BY OWNER'S REPRESENTATIVE. 7.CONTRACTOR SHALL PROVIDE ENHANCED LEAK DETECTION (ELD) IOTA TEST ON SYSTEM AFTER PAVING IS COMPLETE AND PRIOR TO FINAL PROJECT ACCEPTANCE TEST SHALL BE CONDUCTED BY A CERTIFIED TESTER CONTRACTOR SHALL PROVIDE WRITTEN REPORT ON ELD TEST TO OWNER'S REPRESENTATIVE PRIOR TO OWNER'S ACCEPTANCE OF PROJECT. 8.PROVIDE A STATIC PRESSURE (LEAK DECAY) TEST. ACCORDING TO THE AIR QUALITY MANAGEMENT DISTRICT MANUAL OF PROCEDURES OR SOURCE TEST PROCEDURE PER CARB PROCEDURE TP-201. 9.PROVIDE DOCUMENTATION OF A DYNAMIC BACKPRESSURE TEST OF ALL VAPOR RETURN LINES ACCORDING TO CARB PROCEDURE TP-201, OR AS REQUIRED BY LOCAL REGULATIONS. 10.PROVIDE LIQUID REMOVAL TEST FOR BALANCE SYSTEMS (GASOLINE) WITH A LIQUID REMOVAL DEVICE REQUIRED BY A CARB EXECUTIVE ORDER, IF MORE THAN 100 ML OF LIQUID IS FOUND IN THE VAPOR PATH. THIS SHALL BE DETERMINED BY LOWERING THE GASOLINE DISPENSING NOZZLE INTO A CONTAINER AND DRAWING ALL LIQUID, THEN MEASURING THE AMOUNT OF LIQUID, USING A GRADUATED CYLINDER OR BEAKER. IF REQUIRED, THE LIQUID REMOVAL TEST SHALL BE CONDUCTED AND PASSED ACCORDING TO CARB TEST PROCEDURE TP-201. 11.PROVIDE STATIC TORQUE TEST OF ROTATABLE PHASE I VAPOR ADAPTERS ACCORDING TO CARS PROCEDURE TP-201. 12.PROVIDE LEAK RATE TEST OF OVERFILL PREVENTION DEVICE ACCORDING TO CARB PROCEDURE TP-201. 13.PROVIDE LEAK RATE TEST OF PRESSURE/VACUUM VENT VALVES ACCORDING TO CARB PROCEDURE TP-201. 14.PROVIDE ALL OTHER TESTING AS REQUIRED BY STATE AND LOCAL REGULATIONS, MANUFACTURER REQUIREMENTS, AUTHORITIES TO CONSTRUCT, EXECUTIVE ORDERS AND APPROVAL LETTERS, INCLUDING REQUIREMENTS OF VERIFICATION AND REVERIFICATIONS TESTING AFTER SYSTEM OPERATION BEGINS AND AFTER STATUTORY OPERATIONAL INTERVALS REQUIRED AS PART OF THE INSTALLATION REQUIREMENTS OF THE FUELING SYSTEM. INCLUDING (BUT NOT LIMITED TO): USTS, PIPING, DISPENSING, CONTAINMENT, MONITORING AND VAPOR RECOVERY SUB-SYSTEMS. 24.SAFETY PLAN: CONTRACTOR SHALL DEVELOP AND MAINTAIN FOR THE DURATION OF THE CONTRACT A SITE HEALTH & SAFETY PLAN (SAFETY PLAN) THAT WILL EFFECTIVELY INCORPORATE AND IMPLEMENT REQUIRED SAFETY PROVISIONS. AND: A: APPOINT AN EMPLOYEE AS THE SAFETY OFFICER WHO IS QUALIFIED AND AUTHORIZED TO SUPERVISE AND ENFORCE COMPLIANCE WITH THE SAFETY PLAN SUBMIT THE NAME AND OUALIF1CATIONS OF THE SAFETY OFFICER TO THE OWNER'S REPRESENTATIVE PRIOR TO COMMENCING WORK ON THE SITE B: THE SAFETY PLAN SHALL CONTAIN THE NAMES, ADDRESSES AND TELEPHONE NUMBERS OF THE SUPERVISORY PERSONNEL, THE HOSPITAL FACILITIES NEAREST THE SITE, AND A MAP TO THE HOSPITAL. PROCEDURES SHALL BE WRITTEN IN THE SAFETY PLAN FOR ACTIONS TO BE TAKEN SHOULD STRANGE ODORS OR HAZARDOUS SUBSTANCES BE UNCOVERED. C: IF, DURING THE COURSE OF THE WORK UNSAFE CONDITIONS DEVELOP OR ARE ENCOUNTERED, TAKE IMMEDIATE MEASURE TO CORRECT THE CONDITION. IF THE REPRESENTATIVE, CONSTRUCTION WORK SHALL CEASE UNTIL CORRECTIVE ACTION CAN BE IMPLEMENTED. D: PROVIDE A MINIMUM OF TWO FIRE EXTINGUISHERS WITH A MINIMUM CLASS RATING OF 4A:40B:C DRY CHEMICAL WITHIN 30 FEET OF THE OPERATION. 25.UNDERGROUND SERVICE ALERT (USA) - THE CONTRACTOR SHALL NOTIFY MEMBERS OF USA 2 FULL WORKING DAYS IN ADVANCE OF PERFORMING ANY EXCAVATION WORK BY CALLING THE TOLL-FREE ONE-CALL PROGRAM NUMBER (8OO) 227-2600 (OFF-SITE WORK). EXCAVATION 20.ALL EXCAVATIONS SHALL BE PERFORMED IN COMPLIANCE WITH OSHA AND STATE REGULATIONS. THE CONTRACTOR IS REFERRED TO THE OSHA BOOKLET, “EXCAVATING AND TRENCHING OPERATIONS," FOR A SAFE WORK PRACTICES GUIDE FOR PERFORMING EXCAVATION WORK 21.EXCAVATION SHALL BE SIZED PER TANK MANUFACTURER'S GUIDELINES PIPELINE TRENCHING SHALL BE PER PIPELINE MANUFACTURER'S GUIDELINES. 22.THE OWNER RESERVES THE RIGHT TO DESIGN AND/OR CONSTRUCT SHORING UNDER AN AMENDED AGREEMENT WITH CONTRACTOR OR SEPARATELY WITH ANOTHER COMPANY. IF THE OWNER ENGAGES CONTRACTOR, CONTRACTOR SHALL SUBMIT SHORING DESIGN TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL. SUPPLEMENTAL JOB SCOPE AND COST SHALL BE AGREED TO IN TERMS OF A CONTRACT CHANGE ORDER PRIOR TO COMMENCING WORK, SHORING SHALL BE REMOVED PRIOR TO INSTALLING PRODUCT PIPING UNLESS APPROVED BY THE OWNER'S CONSTRUCTION MANAGER TO ABANDON IN PLACE. 23.UNSTABLE SOILS MAY BE REQUIRED TO HAVE A FILTER FABRIC EXCAVATION LINER. CONSULT BID DOCUMENTS OR THE OWNER'S CONSTRUCTION MANAGER FOR SPECIFIC INFORMATION REGARDING THIS ISSUE 24.MINIMIZE SURFACE WATER ENTERING EXCAVATIONS BY CONSTRUCTING 0I1/EASION DAMS AROUND TANK FIELD EXCAVATION AND PIPING TRENCHES. 25.A CONTINGENCY PLAN SHALL BE DEVELOPED WITH THE OWNER'S CONSTRUCTION MANAGER OUTLINING EMERGENCY PROCEDURES FOR OBTAINING THE NECESSARY EQUIPMENT AND/OR PERSONNEL TO HANDLE UNEXPECTED WATER ENTRY INTO TANK FIELD EXCAVATION OR PIPING TRENCHES. WHEN WATER MAY CONTAIN HYDROCARBONS, CONSULT THE OWNER'S CONSTRUCTION MANAGER PRIOR TO REMOVING IT FROM SITE. FUEL SYSTEM 1.PRIOR TO THE START OF WORK, PROVIDE OWNER WITH WORK PLAN AND SCHEDULE THAT COORDINATES SCHEDULING WITH OTHER PORTIONS OF THE PROJECT TO THE FULLEST EXTENT POSSIBLE. 2.CONTRACTOR SHALL COORDINATE DELIVERY DATE OF TANKS WITH THE MANUFACTURER, THE OWNER'S CONSTRUCTION MANAGER AND THE PROJECT SCHEDULE. 3.CONTRACTOR TO PROVIDE 6' CHAIN LINK SECURITY FENCING AND BARRICADES DURING ALL CONSTRUCTION PHASES, OR AS DIRECTED BY THE OWNER'S CONSTRUCTION MANAGER. POST “KEEP OUT” SIGNS ON FENCE EVERY 30 FEET. AT THE END OF EACH WORK DAY, SECURE FENCING PANELS TOGETHER. 4.EXCAVATE AS NECESSARY FOR THE INSTALLATION OF NEW TANK EQUIPMENT, PIPING AND FUEL SYSTEM CONDUITS. 5.WHEN SOIL IS TO BE STOCKPILED ON SITE FOR SAMPLING PRIOR TO OFF-HAUL, PETROLEUM CONTRACTOR SHALL PLACE EXCAVATED SOIL ON AND SHALL COVER WITH 4 MIL. PLASTIC UNTIL SOIL IS REMOVED, IN AN AREA TO BE APPROVED BY OWNER/GENERAL CONTRACTOR (GC) GC SHALL PROVIDE FOR DISTRIBUTION OF ALL EXCAVATED SOIL, PER GENERAL PROJECT REQUIREMENTS 6.INSTALL "TYPAR" FILTER FABRIC LINER IN TANK HOLE AND TRENCHES. WHERE REQUIRED BY WET-HOLE OR UNSTABLE SOIL CONDITIONS, INSTALL TANK HOLD-DOWNS 7.THE OWNER'S CONSTRUCTION MANAGER SHALL WITNESS PRE-INSTALLATION TANK TESTING. CONTRACTOR SHALL NOTIFY THE OWNER'S CONSTRUCTION MANAGER TWO WORKING DAYS PRIOR TO TESTING AND TANK INSTALLATION. 8.TANK MANUFACTURER'S INSTALLATION PROCEDURE SHALL BE FOLLOWED, AND THE INSTALLATION CHECKLIST SHALL BE INITIALED/SIGNED BY CONTRACTOR AND THE OWNER'S CONSTRUCTION MANAGER AS APPROPRIATE AS EACH STEP IS COMPLETED. 9.AN UNDERGROUND EQUIPMENT INSTALLATION AFFIDAVIT SHALL BE FILLED OUT BY CONTRACTOR AND SUBMITTED TO THE OWNER'S CONSTRUCTION MANAGER IN BOUND PROJECT CLOSE OUT FOLDER. 10.CONTRACTOR TO PROVIDE TANK TEST MANIFOLDS PER MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS. PRESSURE GAUGES SHALL BE IN GOOD REPAIR AND HAVE A CALIBRATION DATE WITHIN 30 DAYS OF USE. PRESSURE GAUGES DAMAGED OR OUT OF CALIBRATION WILL NOT BE PERMITTED. 11.THE CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR PROPER HANDLING AND INSTALLATION OF THE UNDERGROUND STORAGE TANKS AND SHALL ENSURE THAT GOOD WORKMANSHIP PRACTICES AND CONSTRUCTION PROCEDURES ARE FOLLOWED REGARDLESS OF THE INCLUSION OR OMISSIONS OF ANY APPLICABLE SUGGESTIONS IN THESE INSTRUCTIONS. 12.UNKNOWN SITUATIONS OR CONDITIONS NOT COVERED IN THESE SPECIFICATIONS AND THE MANUFACTURER'S INSTRUCTIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR. MANUFACTURER'S SPECIALISTS ARE AVAILABLE FOR CONSULTATION. THE PRESENCE OF THE OWNER'S CONSTRUCTION MANAGER OR THE MANUFACTURER'S OBSERVER AT ANY INSTALLATION SITE DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY FOR THE PROPER INSTALLATION OF THE TANKS OR OTHER EQUIPMENT. 13.TANKS SHALL BE PLACED ACCORDING TO THE TANK MANUFACTURER'S INSTALLATION MANUAL AND THE OWNER'S TANK DRAWINGS. PLEASE NOTE THAT IF THE SOIL IS UNSTABLE. THE STANDARDS MAY BE INCREASED. DISTANCE BETWEEN TANKS SHALL BE GOVERNED BY MANUFACTURER'S OR STATE AND LOCAL REQUIREMENTS, WHICHEVER IS GREATER. 14.TANKS ARE TO BE SET LEVEL AND BACKFILLED TO TOP OF TANK THE SAME DAY AS TESTING. 15.INSTALL TANK TRIM & EQUIPMENT PER DRAWINGS AND CURRENT MANUFACTURER'S INSTRUCTIONS, WHICH SHALL BE FOLLOWED AT ALL TIMES, AND SHALL HAVE PRECEDENCE OVER OTHER INSTRUCTIONS. MANUFACTURER'S CHECKLISTS SHALL BE COMPLETED BY THE PETROLEUM CONTRACTOR AS EACH STEP IS COMPLETED. TESTING SHALL CONFORM TD MANUFACTURER'S REQUIREMENTS OWNER'S REPRESENTATIVE SHALL WITNESS ALL TANK TESTING AT HIS/HER DISCRETION. 16.PETROLEUM CONTRACTOR TO INSTALL NEW ELECTRICAL SYSTEMS PER PLANS AND MANUFACTURER'S REQUIREMENTS, ARRANGE FOR ALL INSPECTIONS, PROVIDE CONDUITS/WAITNG, J-BOXES, ETC. REQUIRED FOR ELECTRICAL SYSTEMS. 17.INSTALL EQUIPMENT AS LISTED IN EQUIPMENT LIST AND PROVIDE AND INSTALL ALL OTHER EQUIPMENT AS REQUIRED TO PROVIDE A COMPLETE AND WORKABLE FUELING SYSTEM. 18.PROVIDE AND INSTALL NEW PRODUCT, VENT, VAPOR, AND SECONDARY CONTAINMENT LINES PER DRAWINGS. CURRENT MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED AT ALL TIMES, AND SHALL HAVE PRECEDENCE OVER OTHER INSTRUCTIONS. MANUFACTURER'S CHECKLISTS SHALL BE COMPLETED BY THE PETROLEUM CONTRACTOR AS EACH STEP IS COMPLETED. A: FIBERGLASS REINFORCED PLASTIC (FRP) PIPING: PRIMARY PIPING WITH CONTAINMENT SYSTEM SHALL BE RED THREAD 11A AND RED THREAD 11 WITH FITTINGS AND DS-7000 AND DS-8000 SERIES ADHESIVE, OR AMERON DUALOY 300/LCX WITH ALCOHOL FITTINGS AND PSX34 ADHESIVE. DO NOT MIX DIFFERENT MANUFACTURER'S MATERIALS. ALL PIPING AND CONTAINMENT SYSTEMS SHALL BE UL APPROVED FOR 100% METHANOL. CONTAINMENT SYSTEM SHALL BE BY THE SAME MANUFACTURER WITH THE SAME SERIES ADHESIVES AND/OR FITTINGS. B: VENT/VAPOR PIPING: SAME AS FRP PIPING. C: PERSONS INSTALLING PIPING MUST BE CERTIFIED AS HAVING BEEN TRAINED BY MANUFACTURER, SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 NO PARKING CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/21/2025 SITE ELECTRICAL CONDUIT PLAN SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F5 ALVARO CORONA SHEET F5 1 INSTALL NEW 3/4" CONDUIT WITH POWER, DATA, GROUND AND SENSOR CONDUCTORS - INSTALL NEW 3/4" CONDUIT WITH (1) BELDON #88760 CABLE FOR ANNULAR SENSOR - LOOP TO J-BOX IN FILL SUMP. ITEM 2 3 NEW 1" CONDUIT WITH NEW TURBINE CONDUCTORS AND (4) NEW #12 THWN CONDUCTORS FOR TURBINE POWER AND GROUND TO POWER PANEL. B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 DESCRIPTION INSTALL NEW 3/4" CONDUIT WITH (7) BELDON #88760 CABLES FOR VEEDER ROOT PRESSURE SENSORS, TANK LEVEL, RISER RESERVOIR SENSOR AND PUMP SENSOR - LOOP TO FILL SUMP. 4 INSTALL NEW 3/4" CONDUIT WITH (2) BELDON #88760 CABLES FOR VEEDER ROOT ATMOSPHERIC SMART SENSOR AND VEEDER ROOT SUMP SENSOR. 5 6 ELECTRICAL CONDUIT LEGEND 1 2 3 5 6 4 2'-0" TYP.37'-2" NEW 1" CONDUIT WITH NEW AND NEW BELDON CABLES FOR VEEDER ROOT SENSORS TO EXISTING INTRINSICALLY SAFE WIRE WAY AND VEEDER ROOT TLS-350 PANEL. GENERAL NOTES 1.FURNISH ANY INSTALL COMPLETE ELECTRICAL SYSTEM AS DEPIATED FROM PLANS AND SPECIFICATIONS. 2.THE E.C. SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS WHICH MAY AFFECT HIS BID WORK. 3.ALL UNDERGROUND CONDUITS TO BE MINIMUM OF 3/4" RIGID, PVC COATED RIGID, PVC SCH40. 4.ALL CONDUITS ENTERING AND EXITING THE HAZARDOUS AREAS MUST BE PVC COATED RIGID. ALL OTHER CONDUITS CAN BE SCH40 PVC IF INSTALLED BELOW 24". MIN. 3/4" 5.ALL CONDUCTORS MUST BE THWN TYPE "GAS & OIL" AND SHALL COMPLY WITH THE CODE PROVISIONS FOR THOSE AREAS (ART. 500 TRU 516). 6.ALL SWITCHES TO BE MOUNTED AS PER HANDICAP +48" AFF. 7.ALL CURRENT CARRING CONDUCTORS INSIDE FUEL AREA SHALL BE SWITCH WITH SWITCH NEUTRAL BREAKERS ANY CONTROLLED BY EMERGENCY SHUT OFF CIRCUIT. 8.MAXIMUM PERMITTED CROO-SECTION FILL OF SEALS SHALL NOT EXCEED 25% OF THE CROSS SECTION AREA OF A CONDUIT OF THE SAME TRADE SIZE UNLESS SPECIFICALLY APPROVED. (ART 501-5(C)(6)). 9.ALL EQUIPMENT TO BE U.L. LISTED. 10.ALL WORK SHALL BE DONE IN ACCORDANCE WITH CALIFORNIA ELECTRICAL CODE (2007) EDITION, AND ALL APPLICABLE STATE, COUNTY, AND LOCAL CODES. 11.SEE SHEET F9 FOR ADDITIONAL NOTES AND REQUIREMENTS. HAZARDOUS AREA NOTES A TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK- FILL OPENING) EXTENT OF CLASS 1. GROUP D, DIVISION 1 LOCATIONS: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN DIVISION 1 OR 2 CLASSIFIED LOCATION. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: UP TO 18" ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS OF 10 FEET FROM A LOOSE FILL CONNECTION AND WITHIN A HORIZONTAL RADIUS OF 5 FEET FROM A TIGHT FILL CONNECTION. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK-VENT-DISCHARGING UPWARD EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: WITHIN 3 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATIONS: SPACE BETWEEN 3 FEET AND 5 FEET OF OPEN END VENT, EXTENDING IN ALL DIRECTIONS. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP-OUTDOOR EXTENT OF CLASS 1 GROUP D, DIVISION 1 LOCATION: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL IF ANY PART IS WITHIN A HORIZONTAL DISTANCE OF 10FT. FROM ANY EDGE OF PUMP. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: WITHIN 3 FEET OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. ALSO UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET HORIZONTALLY FROM ANY EDGE OF PUMP. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE-PITS) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION. ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH THE DIVISION 1 OR 2 CLASSIFIED LOCATION. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE-DISPENSER) EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN ANSI/UL 87. "POWER OPERATED DISPENSING DEVICES FOR PETROLEUM PRODUCTS." TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE-OUTDOOR) EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OF THE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE-OUTDOOR) EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF ANY EDGE OF ENCLOSURE. B C D E F G SITE ELECTRICAL PLAN SCALE: 3/32" = 1' - 0" 0'5'10'20' GRAPHIC SCALE NORTH 4 S R A I T T S T . (E) DIESEL 12K PLANTER EXISTING HEALY TANK W EDINGER AVE. (E) 87 12K (E) 91 12K 12 10 11 9 8 6 7 5 4 2 3 1 PLANTER PLANTER BUILDING EXISTING VENTS EXISTING TRASH ENCLOSURE EXISTING REMEDIATION COMPOUND 8' - 0 " SCOPE OF WORK NOT TO AFFECT EXISTING ACCESSIBLE PATH OF TRAVEL 1 5/14/24 NOTED EXISTING ACCESSIBLE PATH OF TRAVEL SIGNED 5/14/24 EXISTING ACCESSIBLE PATH OF TRAVEL EXISTING ACCESSIBLE PATH OF TRAVEL 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 ELECTRICAL NOTES SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F6 ALVARO CORONA SHEET F6 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 ELECTRICAL SPECIFICATIONS PART 1 - GENERAL 1.01 SCOPE OF WORK: FURNISH AND INSTALL ALL MATERIALS AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENCE AND SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND/OR SPECIFIED HEREIN. ALSO INCLUDE ALL OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED, BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION INCLUDING ALL ACCESSORIES AND APPURTENANCES REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. 1.02 REGULATORY REQUIREMENTS: CODE COMPLIANCE IS MANDATORY NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMIT WORK NOT CONFORMING TO THESE CODES. WHERE WORK IS SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (OSHA). 2. NFPA 170: NATIONAL ELECTRIC CODE (NEC). 3. NFPA #101: LIFE SAFETY CODE. 4. STATE FIRE MARSHAL. 5. LOCAL UTILITIES COMPANIES. 6. LANDLORD REQUIREMENTS. 1.03 LICENSE, FEES AND PERMITS: ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMIT AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. 1.04 SAFETY AND INDEMNITY: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, NO ACT. SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER, AND ENGINEERS OR THEIR CONSULTANTS, IS INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN OR NEAR THE CONSTRUCTION SITE. 1.05 DRAWINGS AND SPECIFICATIONS: ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF THIS DIVISION SHOWN ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENT SHALL BE GOVERNED BY CONDITIONS OF THIS JOB. CONSULT ALL OTHER DRAWINGS IN PREPARATION OF THE BID. EXTRA LENGTHS OF WIRING OR ADDITION OF PULL OR JUNCTION BOXES, ETC., NECESSITATE BY SUCH CONDITIONS SHALL BE INCLUDED IN THE BID. 1.06 CONDITIONS AT SITE: VISIT SITE OF THE WORK, COMPARE IT WITH THE DRAWINGS AND SPECIFICATIONS AS TO THE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED, ASCERTAIN AND CHECK ALL CONDITIONS AND ELEVATIONS AND TAKE ALL MEASUREMENTS WHICH MAY AFFECT THE WORK NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE FOR ANY EXTRA EXPENSE OR CLAIMS DUE TO FAILURE OR NEGLECT UNDER THIS REQUIREMENT TO MAKE SUCH EXAMINATION, INCLUDING EXAMINATION OF RESTRICTED WORKING CONDITIONS OR SUCH OTHER DIFFICULTIES VISUALLY OBSERVED DURING SITE VISIT. CONTRACTOR IS RESPONSIBLE FOR BECOMING COMPLETELY FAMILIAR WITH THE ARCHITECTURAL TOOLS AND MATERIALS REQUIRED TO PRODUCE A COMPLETELY CONCEALED INSTALLATION AS INDICATED ON THE PLANS, SPECIFICATIONS, AND REQUIRED BY THE CODE. 1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF THE WORK. 1.08 SHOP DRAWINGS AND MATERIALS LISTS: SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS LIST, AS NOTED BELOW, FOR REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. SUBMITTALS REQUIRED AS FOLLOWS: 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. 2. SWITCHBOARD & ENCLOSURES FOR UTILITY COMPANY METERING. 3. MAIN FUSED DISCONNECT SWITCH. 4. PANEL BOARDS. 5. DISCONNECT SWITCHES. 6. LIGHTING FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. 1.09 SUBSTITUTIONS: ONE OR MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION IS PERMITTED. NO WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE OWNER. THE OWNER IS THE SOLE JUDGE OF ACCEPTABILITY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM IS PERMITTED, AND ANY RE-DESIGN EFFORT IS THEREBY NECESSITATED. THE REQUIRED RE-DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.10 COORDINATION: COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH-IN AND CONNECTION FOR EQUIPMENT FURNISHED UNDER OTHER TRADES THAT REQUIRE ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES OF THE REQUIRED ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABILITY AND CODE COMPLIANCE. VERIFY EQUIPMENT DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. 1.11 CUTTING AND PATCHING: ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION IS INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND OTHER TRADES IS IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER HOLES, SUPPORTS, ETC. 1.12 ACCEPTANCE DEMONSTRATION: UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR THE OWNER THE OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. PROPERLY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND/OR TEST TIME SWITCHES PROGRAMMING. 1.13 RECORD DRAWINGS, EQUIPMENT DATA: MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH "AS-BUILT" INFORMATION AS FEEDER AND SERVICE ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION DELIVER COMPLETED DRAWINGS TO THE OWNER. SUBMIT TO THE OWNER'S REPRESENTATIVE A SET OF "AS BUILT" DRAWINGS IN VELLUM AND CAD FILE. AS BUILT COMMENTS SHALL BE WRITTEN IN A LEGIBLE MANNER IN THE SAME STYLE AS THE CONTRACT DOCUMENTS. ALSO SUBMIT THREE COPIES OF DATA SHEETS OR OTHER CURRENT MANUFACTURERS' PUBLICATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT INCLUDING AT LEAST THESE DATA: 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS LIST. 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. 3. USER'S MANUAL AND OPERATION INSTRUCTIONS. 4. MANUFACTURER'S WARRANTY. 1.14 CLEAN-UP: RID THE PREMISES OF SCARP MATERIALS. TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. 1.15 GUARANTEE: GUARANTEE THE INSTALLATION IS FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHARGE. 1.16 TEMPORARY SERVICES PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE PREMISES. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: 1. THREE 20-AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE GFI TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA REQUIREMENTS. 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARALLEL TO THE DEMISING WALLS, WITH ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN ROWS TO SIXTEEN FEET OR LESS. 3. FLOOD LIGHTING AND TASK LIGHTING FOR PAINTING AND OTHER FINISH WORK. 4. WHEN PERMANENT ELECTRICAL SERVICE IS OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR REMOVAL OF TEMPORARY SERVICE PROVISIONS. 3.03 INSTALLATION OF WIRES: A. PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS BEEN COMPLETED. B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL. SPLICES IN CABLES WHEN REQUIRED SHALL BE MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES. MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8” OF CORRECTLY COLOR-CODED TAILS LEFT IN THE BOX. C. SPLICES IN WIRES AND CABLES SHALL BE MADE UTILIZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. D. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS TO RECEPTACLE AND WIRING DEVICE TERMINALS AS RECOMMENDED BY MANUFACTURE. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE IS NOT APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. E. PROVED BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD. 3.04 WIRE COLOR CODE: COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12AWG THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF ANY SIZE IN CABLE ASSEMBLES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND 120/208V BLACK RED BLUE WHITE GREEN 277/480V BROWN ORANGE YELLOW GRAY GREEN 3.05 IDENTIFICATION: A. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND CIRCUIT NUMBER TO WHICH THE DEVISE IS CONNECTED. B. EACH PANEL BOARD SHALL CONTAIN A METAL-FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. C. PANEL BOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANEL BOARD SCHEDULES FOR ALL PANEL BOARDS. 3.06 REMODELING WORK A. EXISTING ELECTRICAL WIRING WHICH WILL NOT BE MADE OBSOLETE AND WHICH WILL BE DISTURBED DUE TO CONSTRUCTION CHANGES REQUIRED BY THIS CONTRACT SHALL BE RESTORED TO OPERATING CONDITION. WHERE CONSTRUCTION CHANGES REQUIRE, OUTLETS AND CONDUIT RUNS SHALL BE RELOCATED. EXTEND CONDUITS AND PULL IN NEW WIRING OR INSTALL JUNCTION BOXES AND SPLICE IN NEW WIRING. B. OUTLETS FROM WHICH FIXTURES, SWITCHES, RECEPTACLES, AND/OR OTHER ELECTRICAL DEVICES ARE REMOVED AND WHICH ARE NOT REPLACES OR REUSED SHALL BE REMOVED, WHERE OUTLETS BOXES, ETC, ARE COMPLETELY REMOVES, THE CONTRACTOR SHALL CUT OFF CONDUITS AND REMOVE WIRING. C. WHERE CONDUITS EXTENDING THROUGH FLOORS ARE TO BE ABANDONED, THE CONTRACTOR SHALL CUT AND CAP OR D. WHERE EXISTING CONDUIT IS TO BE ABANDONED, THE CONDUIT SHALL BE REMOVED IF IT IS EXPOSED, IN A CRAWL SPACE PLUG CONDUIT, AND THE CONDUIT SHALL NOT PROTRUDE ABOVE THE FLOOR. OR IN ACCESSIBLE CEILING. WHERE IT IS IMPOSSIBLE TO REMOVE THE CONDUIT, IT SHALL BE CUT OFF AND CAPPED OR PLUGGED. E. REMOVE ALL EXISTING WIRING NOT REUSED OR REQUIRED TO MAINTAIN CONTINUITY TO CIRCUITS TO REMAIN. F. THE CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR THE PROPER RESTORATION OF ALL EXISTING SURFACES REQUIRING PATCHING, PLASTERING, PAINTING AND/OR OTHER REPAIRS DUE TO THE INSTALLATION OF ELECTRICAL WORK UNDER THE TERMS OF THIS SPECIFICATION. CLOSE ALL OPENING. REPAIR ALL SURFACES. ETC. AS REQUIRED. G. MAINTAIN CIRCUIT CONTINUITY TO AREAS OUTSIDE OF THIS WORK. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED TO MAINTAIN CONTINUITY AND MAINTAIN AREA AS EXISTING. 3.07 GROUNDING: A. ELECTRICAL SERVICES AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE 250-3 TO 250-26, INCLUSIVE. B. GROUND NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR CABLE TRAYS TO PROVIDE A LOW IMPENDENCE PATH FOR LINE-TO-GROUND FAULT CURRENT AND TO BAND ALL NON-CURRENT CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250-95 UNLESS LARGER CONDUCTORS ARE SHOWN ON DRAWINGS. C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER SIZES, BLACK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVISE ENCLOSURE. HAZARDOUS LOCATION NOTES GENERAL INSTALLATION REQUIREMENTS/FUEL EQUIPMENT COMPATIBILITY: 1. EARTH GROUND IS REQUIRED FOR PROPER EQUIPMENT OPERATION. EACH FUEL-ASSOCIATED DEVICE IS TO BE CONNECTED TO THE GROUND BUS OF THE MAIN POWER PANEL WITH A GREEN INSULATED WIRE TO PROVIDE A SINGLE REFERENCE POINT FOR EARTH GROUND. THE GROUND BUS BAR WILL THEN BE CONNECTED TO A COPPER CLAD GROUND ROD DRIVEN NO LESS THAN 9 FT. INTO THE GROUND. GROUNDING SHALL MEET CEC SECTION 250 REQUIREMENTS. 2. ALL FUEL EQUIPMENT (I.E. DISPENSERS, MONITORING SYSTEM. POS. AND STPS) MUST BE CONNECTED TO THE SAME ELECTRICAL PHASE. 3. EQUIPMENT WHICH COULD POTENTIALLY CREATE ELECTRICAL NOISE OR POWER SURGES (E.G. COOLERS, COMPRESSORS. FLUORESCENT LIGHTING, ETC.) SHALL NOT SHARE A CIRCUIT WITH POS EQUIPMENT. 4. SUBMERSIBLE TURBINE PUMPS (STPS). A. STP CONDUIT SHALL BE PVC COATED RIGID. STPS SHALL NOT SHARE A CIRCUIT WITH PIC OR POS EQUIPMENT. STP WIRING SHALL NOT BE ROUTED THROUGH THE SAME RACEWAY AS THE PIC COMMUNICATION WIRES. B. VARIABLE SPEED STP CONTROLLERS (I.E. RED JACKET OR FE PETRO) SHALL BE INSTALLED A MINIMUM OF 3 FT. FROM THE SAME MODULE. HAZARDOUS LOCATIONS SPECIFICATIONS: A. PROVIDE EXPLOSION PROOF JUNCTION BOX AND SEAL OFF FITTINGS PER ARTICLES 514 OF THE CEC FOR HAZARDOUS LOCATIONS. B. ALL CONDUIT AND WIRING TO FUEL DISPENSERS AND SUBMERSIBLE PUMPS SHALL BE INSTALLED AND USED IN ACCORDANCE WITH FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE NFPA 30 AND APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC) ARTICLE 514. “MOTOR FUEL DISPENSING FACILITIES,” INCLUDING THE FOLLOWING: PROVIDE EXPLOSION PROOF/SEAL-OFF FITTINGS ON ALL POWER SUPPLY LINES LOCATED AT FUEL DISPENSERS, SUBMERSIBLE PUMPS AND ANY OTHER ELECTRICAL EQUIPMENT LOCATED IN A 20' RADIUS OF THE GASOLINE FUEL DISPENSER ISLAND. AN AREA PER FIGURE 5143 OF THE CEC IS DEFINED AS A HAZARDOUS LOCATION WITHIN A 20' RADIUS FROM THE END OF EACH DISPENSER ALL ELECTRICAL EQUIPMENT AND WIRING WITHIN THIS AREA SHALL BE PER CEC 514. C. AN APPROVED SEAL (EXPLOSION PROOF/SEAL-OFF FITTING) SHALL BE PROVIDED IN EACH CONDUIT RUN ENTERING OR LEAVING A DISPENSER OR ANY CAVITIES OR ENCLOSURES IN DIRECT COMMUNICATION THEREWITH. THE SEALING FITTING SHALL BE THE FIRST FITTING AFTER THE CONDUIT EMERGES FROM THE EARTH OR CONCRETE. ADDITIONAL SEAL SHALL BE PROVIDED AT BOUNDARIES IN ACCORDANCE WITH CEC SECTION 501.5 (A)(4) AND 501.5(BX2) APPLYING TO BOTH HORIZONTAL AS WELL AS VERTICAL BOUNDARIES OF CLASS I LOCATIONS. D. PROVIDE EXPLOSION PROOF/SEAL·OFF FITTING AT THE POINT OF CONDUIT STUB-UP ENTRANCE (AT PANEL BOARD) INTO THE SERVICE BUILDING FOR ALL POWER SUPPLY CONDUITS TO FUEL DISPENSERS, SUBMERSIBLE PUMPS AND OTHER ELECTRICAL EQUIPMENT LOCATED IN THE ABOVE DEFINED HAZARDOUS LOCATIONS. E. ALL BELOW GRADE CONDUIT RUNNING THROUGH (ENTERING OR LEAVING - THEN THE ENTIRE CONDUIT RUN SHALL BE RGS) THE CLASS I DIVISION 1 HAZARDOUS LOCATION AS DESCRIBED ABOVE AND AS DEFINED PER CEC ARTICLE 514 SHALL BE RGS. RIGID NON-METALLIC CONDUIT (PVC) MAY ONLY BE USED AS LONG AS THE PROVISIONS OF CEC ARTICLE 514.8. EXCEPTION NO.2 ARE STRICTLY ADHERED TO INCLUDING THE REQUIREMENTS FOR AN EQUIPMENT GROUNDING CONDUCTOR IN THE RIGID NON-METALLIC CONDUIT AND THE EQUIPMENT GROUNDING CONDUCTOR MUST BE BONDED TO THE EXPLOSION-PROOF RACEWAY SYSTEM INSIDE THE DISPENSER (THIS MAY BE ACCOMPLISHED BY TERMINATING THE EQUIPMENT GROUNDING CONDUCTOR ON THE GROUND SCREW PROVIDED IN THE JUNCTION BOX). WHERE RIGID NON-METALLIC CONDUIT IS USED IT SHALL BE USED FOR THE LAST 2 FEET OF THE UNDERGROUND RUN TO EMERGENCE OR POINT OF CONNECTION TO THE ABOVE GROUND RACEWAY. F. EACH CIRCUIT LEADING TO OR THROUGH A DISPENSING PUMP SHALL BE PROVIDED WITH A SWITCH TO DISCONNECT SIMULTANEOUSLY FROM THE SOURCE OF SUPPLY ALL AND CONDUCTORS OF THE CIRCUIT INCLUDING THE GROUNDED CONDUCTOR. G. THE METAL PORTION OF DISPENSING PUMPS, METAL RACEWAYS AND ALL NON-CURRENTCARAYING METAL PARTS OF ELECTRIC EQUIPMENT, REGARDLESS OF VOLTAGE, SHALL BE GROUNDED AS PROVIDED IN CEC ARTICLE 250. ELECTRICAL EQUIPMENT, REGARDLESS OF VOLTAGE, SHALL BE GROUNDED AS PROVIDED IN CEC ARTICLE 250. PART 2 - PRODUCTS 2.01 MATERIAL APPROVAL ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITER'S LABORATORIES LABEL. MATERIALS THAT ARE NOT COVERED BY UL TESTING STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AFTER INSTALLATION. 2.02 CONDUITS AND OTHER RACEWAYS: A. ALL POWER CONDUITS TO BE 3/4" PVC COATED. B. LOW VOLTAGE CONDUITS TO BE 3/4" PVC WITH PVC COATED RIGID ENDS AS REQUIRED IN HAZARDOUS AREAS UNLESS NOTED OTHERWISE. C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO-GALVANIZED. D. WIREWAY: CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND OUTDOORS. 2.03 WIRES AND CABLES: A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: 1. CONDUCTOR: MINIMUM SIZE #12 AWG. A. #12 AND #10 AWG SOLID COPPER. B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. 2. INSULATION TYPE: A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THHN FOR DRY LOCATIONS. B. #1/0 THROUGH #4/0 AWG: XHHW (55 MILS). C. #250 MCM AND LARGER: XHHW (65 MILS). D. GROUNDING WIRE: TW. B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #18 AWG MINIMUM, WITH THWN INSULATION FOR UNDERGROUND OR WET LOCATIONS AND THHN INSULATION FOR DRY LOCATIONS. C. ACCEPTABLE PRODUCTS: GENERAL ELECTRIC. ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING APPLICABLE IPCEA STANDARDS. 2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: A. OUTLET BOXES. 4” SQUARE X 1-1/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO-TYPE WITH PLASTER RING AND COVER FOR GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). B. JUNCTION BOXES (FLOOR BOX NOT INCLUDED) SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE-GAUGE STEEL IN LARGER SIZES WITH SURFACE OR FLUSH-TYPE SCREW-MOUNTED TRIMCOVERS, BOTH BOXES AND COVERS INHIBITOR-PRIMED AND POINTED INSIDE OUT. C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN 4-11/16" SQUARE X 2-1/8” DEEP WITH SINGLE-GONG RING AND SIERRA #S-754N SPLIT PLATE BUSHING. 2.05 WIRING DEVICES AND PLATES: UNLESS OTHERWISE INDICATED, ALL WIRING DEVICES AND COVER PLATES SHALL BE FURNISHED AND INSTALLED IN COLOR TO MATCH FINISH SURFACE WHERE IT IS LOCATED ON, IE, DARK BROWN, BEIGE, WHITE OR STAINLESS STEEL. 2.06 CONDUIT HANGERS: FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR POWERSTRUT. FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM REFLECTION NOT GREATER THAN 1/8”. 2.07 WIRE CONNECTORS: FOR WIRE SIZES #8 AWG AND SMALLER: INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C, 600V, FOR BUILDING WIRING AND 1000V IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL. FOR WIRE SIZE #6 AWG AND LARGER: T & B OR EQUIVALENT COMPRESSION TYPE WITH 3M #33+ OR PLYMOUTH "SLIPKNOT GREY" TAPE INSULATION. 2.08 PANEL BOARDS: A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL BE OF COLD-ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20" FINISH EXPOSED PART WITH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GREY ENAMEL SUITABLE FOR OVERPAINTING IT. B. CIRCUIT BREAKERS: SHALL BE QUICK-MAKE, QUICK-BREAK, MOLDED CASE TYPE: 1. 120/240 VOLT PANELS. SHALL BE GENERAL ELECTRIC TYPE “Q” LINE. BOLT-ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING CAPACITY AS SHOWN. 2. PROVIDE MULTI-POLE UNITS WITH COMMON TRIP ELEMENT. 3. CIRCUIT BREAKERS USED ON "ON-OFF" CONTROL OF FLUORESCENT LIGHTING (PANEL BOARD SWITCHING) SHALL BE UNDERWRITERS' LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABILITY. C. IDENTIFICATION. PROVIDE SCREWED-ON (NO ADHESIVES) BAKELITE OR PHOTO-ETCHED METALLIC NAMEPLATE IDENTIFICATION ON OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE AND PHASE IN MINIMUM 1/8" HIGH LETTERS. EACH PANEL SHALL CONTAIN A METAL-FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. D. COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. 2.09 MISCELLANEOUS MATERIALS: A. SAFETY SWITCHES HEAVY DUTY TYPE, 480V OR 240V, HORSEPOWER RATED FOR MOTORS, FUSED OR NON-FUSED AS REQUIRED. MOUNT IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR WESTINGHOUSE. PART 3 - EXECUTION 3.01 WIRING METHODS: A. INSTALL ALL WIRING IN RACEWAY. OR USE MC GABLE WHERE APPROVED BY ALL APPLICABLE CODES AND REGULATIONS. CONDUIT SHALL BE RIGID STEEL, IMC OR EMC AS FOLLOWS: 1. ABOVE GROUND: USE RIGID STEEL, IMC OR EMT. A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. B. LOCATIONS SUBJECT TO MECHANICAL INJURY RIGID STEEL OR IMC ONLY. C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMT, IMC, OR RIGID STEEL CONDUIT. 2. UNDERGROUND: USE RIGID STEEL B. USE FLEXIBLE CONDUITS OR MC CABLE IN THE FOLLOWING APPLICATIONS: 1. FINAL CONNECTIONS TO MOTOR. 2. FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. 3. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. 4. INTER-CONNECTIONS BETWEEN ALL LIGHT FIXTURES (NOT TO INCLUDE HOMERUN FROM FIXTURE OR DEVICE TO PANEL BOARD, WHICH MUST BE RIGID). 5. FINAL CONNECTIONS WHERE RIGID CONDUIT IS NOT PRACTICAL. 6. IN WALLS (FOR LIGHT SWITCHES AND 120V POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). C. FLEXIBLE METALLIC CONDUIT OR MC CABLE MUST BE THE SAME SIZE AS THE RIGID CONDUIT TO WHICH IT IS CONNECTED. D. THE CONNECTION TO OUTDOOR EQUIPMENT MUST BE WEATHERPROOF. I.E. LIQUID TIGHT OR SEAL TIGHT. E. MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES IF APPROVED BY ALL APPLICABLE CODES MINIMUM SIZE FOR ALL OTHER LOCATIONS SHALL BE 3/4" IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A 3/4" MINIMUM, UNLESS OTHERWISE NOTED ON DRAWINGS. ALL IN/UNDER FLOOR CONDUITS SHALL BE 3/4" MINIMUM SIZE. 3.02 INSTALLATION OF CONDUITS: A. GENERAL: 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENTER LINES OF COLUMNS AND BEAMS. 3. CONDUITS ABOVE CEILINGS SHALL NOT OBSTRUCT REMOVAL OF CEILING TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED WITH MECHANICAL WORK TO AVOID ANY CONFLICT. B. CONDUIT SUPPORTS: 1. SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURES AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY CONDUIT TO MECHANICAL DUCTS AND PIPES. 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING. SUPPORT WIRES WITH CADDY CLIPS ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT IS PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG SUCH CONDUIT SO AS NOT TO AFFECT LEVEL OF CEILING OR LIFTING TILES. 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT IS NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FOR FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURES. C. CONDUIT PENETRATION: 1. PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING. SEAL PENETRATION WITH FIRE RETARDANT SEALANT SPECIFIED HEREIN. 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF ORA EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL: INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS DETAILED ON THE DRAWINGS. 4. PENETRATING NON-FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED. PENETRATIONS MUST BE SEALED WITH PLASTER PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH IS APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH ESCUTCHEONS, ONE ON EACH SIDE OF WALL. 5. PENETRATING SUSPENDED CEILING: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION. PROVIDE ESCUTCHEON FOR EACH CONDUIT BELOW CEILING. CEC TABLE 514.3 (B)(1) - CLASS II, GROUP D LOCATIONS LOCATION UNDERGROUND TANK DIVISION EXTEND OF CLASSIFIED LOCATION FILL OPENING DIV.1 ANY PIT, BOX OR SPACE BELOW GRADE LEVEL. ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. DIV.2 UP TO 18 IN. ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS OF 10 FT. FROM A VENT -DISCHARGING UPWARD DIV.1 WITHIN 3 FT OF OPEN END VENT. EXTENDING IN ALL DIRECTIONS DISPENSING DEVICE DIV.2 SPACE BETWEEN 3 FT. AND 5 FT. OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. PITS DIV.1 ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. DISPENSER SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN "POWER OPERATED DISPENSING DEVISED FOR PETROLEUM PRODUCTS". ANSI/UL 67-1990 DIV.2 WITHIN 18 IN, HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OF THE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. OUTDOOR DIV.2 UP TO 18 IN. ABOVE GRADE LEVEL WITHIN 20 FT. HORIZONTALLY OF ANY EDGE OF ENCLOSURE. REMOTE PUMP-OUTDOOR DIV.1 FROM ANY EDGE OF PUMP. DIV.2 WITHIN 3 FT. OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. ALSO UP TO 1 BIN. ABOVE GRADE LEVEL WITHIN 10 FT. HORIZONTALLY FROM ANY EDGE OF PUMP. SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 GASOLINE GASOLINE GASOLINE GASOLINE GASOLINE GASOLINE+DIESEL CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 VEEDER ROOT ELECTRICAL SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 07/19/2023 5669 F7 ALVARO CORONA SHEET F7 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 SENSOR ALARM SUMMARY OTHER ALARMS ISD ALARM SUMMARY DISPLAY MESSAGE INDICATOR LIGHT AUDIBLE ALARM ACTIVATION RESULTS CAUSE LIQUID SENSOR STATUS INDICATORS - PIPING SUMP SENSOR (VR-794390-208) & STEEL TANK INTERSTITIAL SENSOR (VR-794390-420) FUEL ALARM RED YES SHUT DOWN OF PROGRAMMED DEVICES, AUDIO, VISUAL & PRINTED COPY OF ALARM AN INTERSTITIAL OR PIPING SUMP LIQUID SENSOR DETECTS LIQUID IN A TANK'S INTERSTITIAL SPACE OR PIPING SUMP. SENSOR OUT ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES, AUDIO, VISUAL & PRINTED COPY OF ALARM A SENSOR IS DISCONNECTED OR IS NOT FUNCTIONING PROPERLY SHORT ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES, AUDIO, VISUAL & PRINTED COPY OF ALARM AN INTERNAL SHORT HAS OCCURRED IN THE SENSOR SETUP DATA WARNING YELLOW YES AUDIO, VISUAL & PRINTED COPY OF ALARM PROGRAMMING ERROR PRESSURIZED LINE LEAK DETECTOR STATUS INDICATOR - PLLD SENSORS WITH SWIFT CHECK VALVE (VR-848480-003) SHUTDOWN ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES, AUDIO, VISUAL & PRINTED COPY OF ALARM SYSTEM SHUT DOWN LINE BECAUSE OF FAILED LINE LEAK TEST, OR AN ALARM ASSIGNED TO DISABLE THE LINE IS ACTIVE GROSS LINE FAIL RED YES SHUTDOWN OF PROGRAMMED DEVICES. AUDIO, VISUAL & PRINTED COPY OF ALARM A.3GPH (11.3 LPH) LINE TEST FAILURE. DISPENSING HALTS WHILE A.LARM IS ACTIVE. FUEL OUT RED YES SHUTDOWN OF PROGRAMMED DEVICES. AUDIO, VISUAL & PRINTED COPY OF ALARM TANK PRODUCT LEVEL BELOW 10-INCH ( 25.4 CM) LEVEL. CANNOT PUMP WHEN ACTIVE, DELIVERY NEEDED SETUP DATA WARNING YELLOW YES AUDIO, VISUAL & PRINTED COPY OF ALARM THE DEFAULT LINE LENGTH WAS NOT CHANGED TO REFLECT THE ACTUAL LINE LENGTH OPEN ALARM RED YES SHUTDOWN OF PROGRAMMED DEVICES. AUDIO, VISUAL & PRINTED COPY OF ALARM PRESSURE SENSOR READING IS LESS THAN -8PSI (-51.2 KPA). ONLY TESTED WHILE PUMP IS RUNNING DISPLAYED MESSAGE ISD MONITORING CATEGORY INDICATOR LIGHT OPEN ALARM ISD VAPOR LEAKAGE WARN CONTAINMENT YELLOW VAPOR LEAKAGE DETECTION TEST - WARNING ISD VAPOR LEAKAGE FAIL*CONTAINMENT RED VAPOR LEAKAGE DETECTION TEST - 8TH CONSECUTIVE FAILURE ISD GROSS PRESSURE WARN CONTAINMENT YELLOW GROSS OVER-PRESSURE TEST - WARNING ISD GROSS PRESSURE FAIL*CONTAINMENT RED GROSS OVER-PRESSURE TEST - 8TH CONSECUTIVE FAILURE ISD DEGRAD PRESSURE WARN CONTAINMENT YELLOW DEGRADATION OVER-PRESSURE TEST - WARNING ISD DEGRAD PRESSURE FAIL*CONTAINMENT RED DEGRADATION OVER-PRESSURE TEST - 30TH CONSECUTIVE FAILURE HM: GROSS COLLECT WARNING COLLECTION YELLOW 1-DAY GROSS A/L TEST - WARNING HM: GROSS COLLECT FAIL*COLLECTION RED 1-DAY GROSS A/L TEST - 2ND CONSECUTIVE FAILURE HM: DEGRAD COLLECT WARNING COLLECTION YELLOW 7-DAY DEGRADATION A/L TEST - WARNING HM: DEGRAD COLLECT FAIL*COLLECTION RED 7-DAY DEGRADATION A/L TEST - CONSECUTIVE FAILURE ISD SENSOR OUT PRESSURE WARN SELF-TEST YELLOW ISD SENSOR OUT (SELF-TEST) - WARNING ISD SENSOR OUT PRESSURE FAIL*SELF-TEST RED ISD SENSOR OUT (SELF-TEST) - 8TH CONSECUTIVE FAILURE ISD SETUP WARNING SELF-TEST YELLOW SYSTEM SETUP (SELF-TEST) - WARNING ISD SETUP FAIL*SELF-TEST RED SYSTEM SETUP (SELF-TEST) - 8TH CONSECUTIVE FAILURE DISPLAYED MESSAGE INDICATOR LIGHT SET CONDITIONS CLEAR CONDITIONS MISSING REPLAY SETUP RED ONE OR MORE REQUIRED SHUT DOWN ALARMS HAVE NOT BEEN ASSIGNED TO A RELAY SETUP REQUIRED SHUT DOWN ALARMS MISSING TANK SETUP RED THERE ARE NO VAPOR RECOVERY (GASOLINE) TANKS DEFINED OR A GASOLINE PUMP HAS NOT BEEN ASSIGNED TO A CONTROL (SHUT DOWN) DEVICE IN AT LEAST ONE TANK. COMPLETED GASOLINE TANK SETUP MISSING HOSE SETUP RED THERE ARE NO PRODUCT METERS ASSIGNED TO A HOSE ASSIGN AT LEAST 1 PRODUCT METER TO A HOSE HM: VAPOR FLOW METER SETUP RED INCOMING TRANSACTION FROM A HOSE WITH AN UNAVAILABLE VAPOR FLOW METER CONFIGURE VAPOR FLOW METER (SMART SENSOR) AND ENABLE IT IN ISD MISSING VAPOR PRESSURE SENSOR RED THERE IS NO VAPOR PRESSURE SENSOR SETUP OR DETECTED COMPLETE VAPOR PRESSURE SENSOR SETUP MISSING VAPOR FLOW METER RED THERE IS NO VAPOR FLOW METER SETUP OR DETECTED COMPLETE VAPOR FLOW METER SETUP HM: CHECK VAPOR FLOW METER RED FAILURE OF VOLUME MEASURE TEST. POSSIBLE PROBLEM - VAPOR FLOW METER VOLUME MEASURE TEST PASSES OR VAPOR FLOW METER DECONFIGURED OR TEST CLEARED IMPORTANT: THIS IS A CONTROL DRAWING ONLY AND DOES NOT REFLECT THE ACTUAL LOCATIONS OF CONDUIT ENTRY (SEE NOTE 7 BELOW). WARNING: IN INSTALLATION AND USE OF THIS PRODUCT, COMPLY WITH THE NATIONAL ELECTRICAL CODE; FEDERAL, STATE AND LOCAL CODES. IN ADDITION, TURN OFF POWER AND TAKE OTHER NECESSARY PRECAUTIONS DURING INSTALLATION, SERVICE AND REPAIR TO PREVENT PERSONAL INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. WARNING: DISCONNECT ALL POWER BEFORE MAKING ANY CONNECTIONS TO PREVENT DEATH, SERIOUS INJURY, EXPLOSION, OR ELECTRICAL SHOCK. MONITOR MUST NEVER BE OPERATED UNLESS THE FRONT COVER IS CLOSED OVER THE BARRIER TERMINALS IN THE INTRINSICALLY SAFE AREA . 1. INTRINSICALLY SAFE WIRING BONDED CONDUIT MEANS THAT THE METALLIC SECTIONS OF CONDUIT ARE PERMANENTLY JOINED TO FORM AN ELECTRICALLY CONDUCTIVE PATH THAT WILL ASSURE ELECTRICAL CONTINUITY, AND THAT THE CONDUIT HAS THE CAPACITY TO CONDUCT SAFELY, ANY CURRENT LIKELY TO BE IMPOSED. A) BONDED & NON-BONDED - THE WIRES BETWEEN THE MONITOR AND EACH PROBE/SENSOR LOCATION MUST BE #14, #16 OR #18 AWG STRANDED COPPER WIRES WITHIN A SHIELDED CABLE. SHIELDED CABLE UST BE RATED AT LESS THAN 100 PICOFARAD PER FOOT AND MUST BE MANUFACTURED WITH A MATERIAL SUITABLE FOR THE ENVIRONMENT, SUCH AS CAROL(TM) C2534 OR BELDEN(TM) 88760 OR 8760. 2. CONNECT THE BARRIER GROUND TO THE EARTH GROUND BUS AT THE POWER DISTRIBUTION PANEL WITH #12 AWG (OR LARGER) CONDUCTOR. 3. DENOTES FIELD WIRING CONNECTION USING WATERPROOF CONNECTORS SUPPLIED WITH THE PROBE(S) AND SENSOR(S). 4. INTRINSICALLY SAFE WIRING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 504-20 OF THE NEC, ANSI/NFPA 70. 5. TO MAINTAIN INTRINSIC SAFETY, PROBE/SENSOR WIRING MUST BE INSTALLED WITH EITHER SEALED CONDUIT OR DIRECT BURIAL METHODS. REFER TO "DIRECT BURIAL CABLE INSTALLATION", MANUAL NO. 576013-858. 6. ELECTRICAL RATING POWER INPUT 120 VAC, 50/60 HZ, 100 VA MAXIMUM. 7. THIS DOCUMENT IS NOT TO BE USED AS A SUBSTITUTE FOR SPECIFIC EQUIPMENT INSTALLATION MANUALS. FOR INSTALLATION DETAILS USE THE RESPECTIVE MANUAL: TLS-350(R)576013-879 PLLD 576013-902 WPLLD 576013-923 REPORT PRINTER MULTIPORT CARD OR RS-232 CARD SMART SENSOR MODULE DIM CARD SENSOR MODULE 1/0 COMBO MODULE OUTPUT RELAY MODULE EVR/ISD SYSTEM LL CONTROLLER MODULE PLLD CONTROL MODULE NVMEM BOARD - FLAS EEPROM & RAM (REQUIRED) SENSOR MODULE PROBE MODULE SYMBOL LEGEND * ISD SETUP TLS SETUP * ** ** CONNECT TO PUMP CONTROL OF THE SELF SERVE SYSTEM. OR DISPENSER, ON THE PRODUCT RELAY OR PUMP CONTRACTOR TO PUMP CONTROLS (SEE NOTE 7.) CIRCUIT BREAKER PANEL WATER WHITE GREEN BLACK GROUND REDFUEL VAPOR WHITE BLACK WATER GROUND RED BLACK WHITE GROUND B A WHITE WHITE WHITE BLACK BLACK BLACK (E)JUNCTION BOX NON - HAZARDOUS AREA HAZARDOUS AREA WEATHERPROOF JUNCTION BOXES 1 PER PROBE OR SENSOR (13) SUMP SENSORS (3) TANK LEVEL PROBES (3) TANK ANNULAR (7) PIPING VAC SENSORS (1) ATMOSPHERIC SENSOR (1) ISD PRESSURE SENSOR (13) RESERVOIR SENSORS (3) PLLDs (6) ISD FLOW METERS MODEL #794380-208 (4 AT TANKS- 6 AT DISPENSERS) MODEL #847390-111 MODEL #794390-303 MODEL #330020-471 MODEL #33250-001 (1 AT VAPOR POLISHER) MODEL #331946-001 MODEL #794380-304 (4 AT TANKS- 6 AT DISPENSERS 1 AT VENT TRANSITION SUMP) MODEL #848480-001 MODEL #332374 WPLLD CONNECTION TO L1 & L2 (PUMP POWER) FOR DATA COLLECTION WPPLD TO PUMP CONTROLS (SEE NOTE 7.) AIR FLOW METER VAPOR PRESSURE SENSOR DISPENSER FUEL METER DATA SUMP SENSORS ISD REPORT ACCESS RS-232 OVERFILL ALARM OR STP CONTROL PLLD's MAG PROBES SUMP SENSORS NEW TLS-350 PANEL ATMOSPHERIC SENSOR HEALY TANK 2" VENTS TO VENT RISERS AND CANISTERS DISPENSER VAPOR RETURN LINE TANK #1 TANK #2 MAG PROBE MAG PROBE STPSTP TO TLS CONSOLE TO TLS CONSOLE TO TLS CONSOLE TO TLS CONSOLE 91 U/L87 U/L TO SMART SENOR MODULE TO SMART SENOR MODULE TO SMART SENOR MODULE TO SMART SENOR MODULE DISPENSER VAPOR RETURN LINE TO TANKS VAPOR PRESSURE SENSOR (1 PER SITE) AIR FLOW METER (1 PER DISPENSER) FROM HOSE VAPOR LINE BARRIER GROUND CHASSIS GROUND AC NEUTRAL AC LINE RIGID CONDUIT VEEDER ROOT TLS-350 PANEL INSTALL NEW SOFTWARE VERSION 1.05 1 2 3 41234 PROBE/THERMISTOR INTERFACE MODULE PROBE THERMISTOR 1 2 3 4 5 6 1 2 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 1 1 1 1 2 2 3 3 4 4 5 5 2 2 3 3 4 4 5 5 2 3 4 5 6 CA B CA B CA B CA B CA B CA B GF W GF W GF W GF W GF W GV W GV W GV W GV W GV W 1 2 3 4 3 3 4 4 M UPR PO M UPR PO M UPR PO M UPR PO M UPR PO M UPR PO NC NO C NC NO C I/D COMBINATION MODULE PRESSURE LINE LEAK CONTROLLER MODULE WPLLD CONTROLLER MODULE WPLLD AC INTERFACE MODULE PUMP SENSE MODULE SMART SENSOR / PRESS MODULE INTERSTITIAL SENSOR INTERFACE MODULE VAPOR SENSOR INTERFACE MODULE GROUNDWATER SENSOR INTERFACE MODULE TYPE A INTERFACE MODULE TYPE B INTERFACE MODULE PRESSURE LINE LEAK INTERFACE MODULE NC NO C NC NO C INPUT OUTPUT OVERFILL ALARM - MODEL #790091-001 ACKNOWLEDGMENT SWITCH - MODEL #790095-001 (SHIELD DEVICE CABLES) RIGID CONDUIT TERMINATION POINTS FOR SHIELDED CABLE 115 VAC HOT 115 VAC NEUTRAL N L 1 2 3 RIGID CONDUIT RIGID CONDUIT INPUT RELAY PRESSURE XMIT PROBE THERMISTOR SENSOR SENSOR GROUND WATER SENSOR VAPOR SENSOR SENSOR SMART SENSOR PUMP 1-2 3-4 5-6 7-8 9-10 SUMP SENSOR 323 304 TANK #3 MAG PROBE STP TO TLS CONSOLE TO TLS CONSOLE DIESEL SUMP SENSOR 323 304 SUMP SENSOR 323304 SUMP SENSOR 323304 SUMP SENSOR 208 304 11-12 304 TO SMART SENOR MODULE TO SMART SENOR MODULE SUMP SENSOR 208 SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 ELECTRICAL DETAILS SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F8 ALVARO CORONA SHEET F8 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 NOTE: CONTRACTOR TO FURNISH AND INSTALL ALL COMPONENTS TO MAKE ALL GROUNDING CONNECTIONS AS REQUIRED BY LOCAL AGENCIES. 13 26 7 8 5 4 SCALE: SCALE:SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: NTSNTS NTSNTS NTS NTS 3"=1'-0" NTS CONDUIT TRENCH DETAIL STORAGE TANK GROUNDING DETAIL TYPICAL CONDUIT STUN-UP DETAIL CONDUIT STUN-UP DETAIL DISPENSER GROUNDING DETAIL (IF REQUIRED) DISPENSER CONDUIT DETAIL ASPHALT TO ASPHALT PATCH BACK NOTES: 1. THREADED PVC COATED RIGID METAL CONDUIT SHALL BE USED FOR THE LAST 2 FEET OF UNDERGROUND RUN TO EMERGENCE PER N.E.C. 514. 2. UNDERGROUND PVC CONDUIT SHALL BE USED ONLY AS ALLOWED BY N.E.C. 514-8, EXCEPTION NO. 2 AND APPLICABLE LOCAL CODES. VERIFY SUITABILITY WITH ALL APPROPRIATE AGENCIES. PVC CONDUIT SHALL BE SCHEDULE 40 OVER OR HEAVIER WITH ALL PORTIONS BURIED A MINIMUM 2 FEET BELOW GRADE. NOTE: CONTRACTOR TO FURNISH AND INSTALL ALL COMPONENTS TO MAKE ALL GROUNDING CONNECTIONS AS REQUIRED BY LOCAL AGENCIES. CONTRACTOR TO FIELD VERIFY PAVEMENT THICKNESS AND MATCH EXISTING EXISTING PAVING NEW PAVING NATIVE SOIL EXISTING 4" ROCK BASE OR MATCH EXISTING AC PAVING/CONC. WHERE INDICATED. REPAIR TRENCH TO MATCH EXIST. +1" IN THICKNESS (5"MIN) (E) GRADE (MATCH) CONDUIT (TYP.) CONDUIT SPACER (TYP.) 2'-0" 12" MIN. COMPACTED SOIL - 95% MAX. DENSITY PAVING 8" THK. CRUSHED ROCK @ AC COMPACTED TO 95% MAX. DENSITY 18" MIN. FINISHED SURFACE CONDUITS (STUBBED-UP 18" A.F.F.) CONDUIT SEAL-OFF AT ALL BOUNDARIES OF HAZARDOUS AREAS UNDER DISPENSER CONTAIMENT BRACKET (DO NOT PENETRATE SUMP) 1" CONDUIT TO CONTROL PANEL FOR POWER & DATA 3/4" CONDUIT TO SALES AREA FOR INTERCOM 3/4" CONDUIT TO MONITOR SYSTEM FOR BRINE & LIQUID SENSOR EXPLOSION SEAL OFF APPLETON GR 75 OR EQUAL EXPLOSION PROOF J-BOX APPLETON GRSS75 OR EQUAL 24" MIN. SEAL (TYP.) PVC COATED RIGID CONDUIT BUILDING WALL DISPENSER PVC CONDUIT PVC TO METAL CONUIT COUPLER (TYP.) EXISTING GUTTER BOX INTRINSICALLY SAFE PVC COATED RIGID STEEL CONDUIT DISPENSER SUMP PENETRATION BOOT DISPENSER SUMP PAINT BOLTS AND NUTS BLACK TO BLEND WITH FRAME JUNCTION BOX STABILIZER FROM FRAME OF DISPENSER MOUNTING BRACKET MOUNTING BOLT CRIMPON LUGS TO WIRE EXP. JUNCTION BOX WITH GROUND #10 STANDARD WIRE CONDUIT CRIMPON LUGS TO WIRE DISPENSER LOWER BEZEL-AXCESS TO METER AND SHEAR VALVE LOWER BASE OF DISPENSER FRAME CONCRETE SLOPE AT BOX 3/8" BOLT X 1 1/2" 3/8" NUTS-TYPICAL (3) DISPENSER BOX CONTRACTOR TO DRILL 7/16" HOLE IN BASE FOR MOUNTING GROUND INSIDE DISPENSER 3/8" CRIMP ON CONNECTOR CONC. SLAB 12" MANHOLE GROUND ROD CLAMP 5/8" X 8'-0" GROUND ROD INTO NATIVE SOIL GROUND WIRE TO GROUND ROD NATIVE SOIL CONDUIT CLAMPS RISER SPACER 4" RISER 4" 6" SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 ELECTRICAL DETAILS SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/23/2023 5669 F9 ALVARO CORONA SHEET F9 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 TLS 350 GUTTER BOX UD C S U M P 1 / 2 UD C S U M P 3 / 4 UD C S U M P 5 / 6 UD C S U M P 7 / 8 VE N T S U M P MINI HYDROSTATIC SENSOR 36 3-WAY RELIEF BALL VALVE (TYP.) 57 MINI HYDROSTATIC SENSOR 36 MINI HYDROSTATIC SENSOR 36 MINI HYDROSTATIC SENSOR 36 MINI HYDROSTATIC SENSOR 36 3-WAY RELIEF BALL VALVE (TYP.) 57 91 DIESEL VR MINI HYDROSTATIC SENSOR36 FILL SUMP VAC J-BOX WITH CORD GRIP ENTRIES MONITOR PANEL TURBINE SUMP POWER 12K GALLON DIESEL TANK 3-WAY RELIEF BALL VALVE (TYP.) 57 2 ZONE VACUUM SENSOR WITH MOUNTING KIT 74 VACUMM SOURCE FROM TURBINES' SIPHON CHECK VALVE PORT TURBINE SIPHONE CHECK VALVE VAC VACVAC VAC PR O D . L I N E D D VE N T D VENT D V E N T VR VR VR 91 91 91 87 87 87 QTY SENSOR / MAKE / MODEL LOCATION MODE 1 3 ZONE VACUUM SENSOR VEEDER ROOT #330020-485 TANK #1 (87) #1 - PRODUCT #2 - VENT #3 - VAPOR RETURN 1 2 ZONE VACUUM SENSOR VEEDER ROOT #330020-480 TANK #2 (91)#1 - PRODUCT #2 - VENT 1 2 ZONE VACUUM SENSOR VEEDER ROOT #330020-480 TANK #3 (DIESEL)#1 - PRODUCT #2 - VENT NOTES 1.ALL VACUUM TUBING MUST BE VEEDER ROOT APPROVED VACUUM TUBING. 2.AN EXTERNAL SIPHON CHECK VALVE MUST BE USED WHEN MAKING A VACUUM SOURCE CONNECTION BETWEEN THE SCVS SYSTEM SENSORS AND THE SIPHON PORT CARTRIDGE FOR ALL TURBINES. 3.DOUBLE WALL OF ALL PRODUCT, VENT, AND VAPOR RETURN PIPING TO BE VACUUM MONITORED. 4.DOUBLE WALL OF ALL TURBINE SUMP, FILL SUMP, UDC, AND VENT TRANSITION SUMP TO BE HYDROSTATIC MONITORED. 5.DOUBLE WALL OF ALL UST'S TO BE HYDROSTATIC MONITORED. 87 VAPOR RETURN 91 87 VR 91 87 3-WAY RELIEF BALL VALVE (TYP.) 57 VAPOR RETURN 91 87 VR 91 87 3-WAY RELIEF BALL VALVE (TYP.) 57 3-WAY RELIEF BALL VALVE (TYP.) VAPOR RETURN 91 87 VR 91 87 VAPOR RETURN 91 87 VR 91 87 MINI HYDROSTATIC SENSOR36 FILL SUMP VAC VAC J-BOX WITH CORD GRIP ENTRIES MONITOR PANEL TURBINE SUMP POWER 12K GALLON 87 TANK 3-WAY RELIEF BALL VALVE (TYP.) 57 3 ZONE VACUUM SENSOR WITH MOUNTING KIT 16 VACUMM SOURCE FROM TURBINES' SIPHON CHECK VALVE PORT TURBINE SIPHONE CHECK VALVE VACVACVAC VACVAC VAC 3" OVER 2" FRP FOR VEEDER ROOT TUBING VACUUM MONITORING PR O D . L I N E 87 87 87 VA P O R R E T U R N VE N T VR VENT MINI HYDROSTATIC SENSOR36 FILL SUMP VAC J-BOX WITH CORD GRIP ENTRIES MONITOR PANEL TURBINE SUMP POWER 12K GALLON 91 TANK VACUMM SOURCE FROM TURBINES' SIPHON CHECK VALVE PORT TURBINE SIPHONE CHECK VALVE VAC VACVAC PR O D . L I N E 91 91 91 VE N T VENT 87 V E N T 87 V E N T 87 V E N T 91 V E N T D D D D UD C S U M P 9 / 1 0 MINI HYDROSTATIC SENSOR 36 3-WAY RELIEF BALL VALVE (TYP.) 57 VAPOR RETURN 91 87 VR 91 87 UD C S U M P 1 1 / 1 2 MINI HYDROSTATIC SENSOR 36 3-WAY RELIEF BALL VALVE (TYP.) 57 VAPOR RETURN 91 87 VR 91 87 DIESEL D VR 91 87 VR 87 VR 91 87 VR 91 87 VR 91 87 VAC 3-WAY RELIEF BALL VALVE (TYP.) 57 2 ZONE VACUUM SENSOR WITH MOUNTING KIT 74 SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 ASSEMBLYPUMP-MOTORPETROLEUM CM FARLAND, WI MINI-HYDO SENSOR SUMP SENSOR AT LOWEST POINT 4" BLACK IRON RISER EXISTING STEEL STRIKER PLATES TYP. SWIVEL FILL ADAPTOR EXPLOSION PROOF J-BOX W/SEAL-OFF (TYP.) DOUBLE WALL FIBERGLASS SUMP FILL CAP NEW 42" MULTIPORT COVER W/ (2) 5 GALLON BUCKETS WATER TIGHT SHROUD ASSEMBLY SWIVEL STAGE I VAPOR ADAPTOR EXTRACTOR TEE W/ PLUG 6" 45 ° TO VEEDER-ROOT PANEL STAGE I VAPOR CAP OVERFILL PROTECTION DROP TUBE SET AT 95% (TYP.) RISER SUPPORT BRACKET 24 38 17 45 36 19 SUMP SENSOR AT LOWEST POINT DOUBLE WALL FIBERGLASS SUMP TO VEEDER-ROOT PANEL CONDUIT PENETRATION 24 38 4 3" OVER 2" FRP TO TURBINE SUMP4241 3" OVER 2" FRP VENT PIPE4241 4" OVER 3" FRP VAPOR RETURN 42 41 5" 2" SS BALL VALVE PLLD TURBINE MANHOLE COVER ATG CONDUIT PENETRATION TO VEEDER-ROOT PANEL EXPLOSION PROOF J-BOX W/SEAL-OFF DOUBLE WALL FIBERGLASS SUMP SET AUDIBLE & VISUAL ALARM @ 90% CAPACITY 2" FLEX CONNECTOR NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION 3" OVER 2" FRP TO FILL SUMP 3" OVER 2" FRP PRODUCT LINE VAC SENSORS CONDUIT PENETRATION 12"x24"x11GA STEEL STRIKER PLATES TYP. UNDER ALL OPENINGS W/ MANWAYS ON FIBERGLASS TANK (BY TANK MANF.) TRAPPER SCREEN SUMP SENSOR AT LOWEST POINT DOUBLE WALL FIBERGLASS SUMP EXTRACTOR TEE CONDUIT PENETRATION TO VEEDER-ROOT PANEL NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION EXPLOSION PROOF J-BOX W/SEAL-OFF TURBINE PLLD CONDUIT PENETRATION 3" OVER 2" FRP TO FILL SUMP VAC SENSORS 3-WAY BALL VALVE (TYP.) 3" OVER 2" FRP PRODUCT LINE NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION 2" FLEX CONNECTOR 3"X3" FOAM SPACER PER MANUFACTURER'S SPECIFICATIONS SUMP SENSOR AT LOWEST POINT EXTRACTOR TEE BALL BLOAT SET @ 95% OF TANK CAPACITY 38 38 26 26 4 4 4 4 4241 4241 4241 25 25 11 11 17 17 45 45 1 1 23 57 10 MINI-HYDO SENSOR SUMP SENSOR AT LOWEST POINT 4" BLACK IRON RISER EXISTING STEEL STRIKER PLATES TYP. SWIVEL FILL ADAPTOR EXPLOSION PROOF J-BOX W/SEAL-OFF (TYP.) DOUBLE WALL FIBERGLASS SUMP FILL CAP NEW 42" MULTIPORT COVER W/ (2) 5 GALLON BUCKETS WATER TIGHT SHROUD ASSEMBLY SWIVEL STAGE I VAPOR ADAPTOR EXTRACTOR TEE W/ PLUG 6" 45 ° TO VEEDER-ROOT PANEL STAGE I VAPOR CAP OVERFILL PROTECTION DROP TUBE SET AT 95% (TYP.) RISER SUPPORT BRACKET 24 38 17 45 36 19 SUMP SENSOR AT LOWEST POINT DOUBLE WALL FIBERGLASS SUMP TO VEEDER-ROOT PANEL CONDUIT PENETRATION 24 38 4 3" OVER 2" FRP TO TURBINE SUMP4241 3" OVER 2" FRP VENT PIPE4241 4" OVER 3" FRP VAPOR RETURN 42 41 5" 2" SS BALL VALVE PLLD TURBINE MANHOLE COVER ATG CONDUIT PENETRATION TO VEEDER-ROOT PANEL EXPLOSION PROOF J-BOX W/SEAL-OFF DOUBLE WALL FIBERGLASS SUMP SET AUDIBLE & VISUAL ALARM @ 90% CAPACITY 2" FLEX CONNECTOR NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION 3" OVER 2" FRP TO FILL SUMP 3" OVER 2" FRP PRODUCT LINE VAC SENSORS CONDUIT PENETRATION 12"x24"x11GA STEEL STRIKER PLATES TYP. UNDER ALL OPENINGS W/ MANWAYS ON FIBERGLASS TANK (BY TANK MANF.) TRAPPER SCREEN SUMP SENSOR AT LOWEST POINT DOUBLE WALL FIBERGLASS SUMP EXTRACTOR TEE CONDUIT PENETRATION TO VEEDER-ROOT PANEL NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION EXPLOSION PROOF J-BOX W/SEAL-OFF TURBINE PLLD CONDUIT PENETRATION 3" OVER 2" FRP TO FILL SUMP VAC SENSORS 3-WAY BALL VALVE (TYP.) 3" OVER 2" FRP PRODUCT LINE NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION 2" FLEX CONNECTOR 3"X3" FOAM SPACER PER MANUFACTURER'S SPECIFICATIONS SUMP SENSOR AT LOWEST POINT EXTRACTOR TEE BALL BLOAT SET @ 95% OF TANK CAPACITY 38 38 26 26 4 4 4 4 4241 4241 4241 25 25 11 11 17 17 45 45 1 1 23 57 10 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 UST & SUMP DETAILS SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/23 5669 F3-1 ALVARO CORONA SHEET F3-1 B A C D E F G H J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 SECTION THROUGH TANK AND EXCAVATION SCALE: 1/4" = 1' - 0" TURBINE FILL ANNULAR MONITOR DETAIL C - THIS SHEET 8" 4' - 0 " 8' - 0 " DE P T H T O G R O U N D W A T E R + - 2 4 ' B F G SO U R C E : A N T E A G R O U P ( 8 0 0 - 4 7 7 - 7 4 1 1 ) A 13 TANK SHALL BE INSTALLED BY XERXES TANK CERTIFIED CONTRACTOR. LEAK MONTORING SYSTEM SHALL BE INSTALLED BY VEEDER ROOT CERTIFIED CONTRACTOR. PIPING SYSTEM TO BE INSTALLED A.O. SMITH CERTIFIED CONTRACTOR. UNDER DISPENSER CONTAINMENT SUMPS SHALL BE INSTALLED BY BRAVO CERTIFIED CONTRACTOR. TESTING AND CERTIFICATION SHALL BE DONE BY AN I.C.C. CERTIFIED TECHNICIAN. 37'-2" UNDERGROUND STORAGE TANK - XERXES 2'-0" (MIN.) 8'-0" (TYP.) 2'-0" (MIN.) 8" 4' - 0 " 8' - 0 " 4' - 0 " 4'-0" DE P T H T O G R O U N D W A T E R + - 2 4 ' B F G SO U R C E : A N T E A G R O U P ( 8 0 0 - 4 7 7 - 7 4 1 1 ) 13 13 STEEL MANWAY (TYP.) DETAIL AT 87 TANK TURBINE SUMP SCALE: 1/2" = 1' - 0" DETAIL AT 87 TANK FILL SUMP SCALE: 1/2" = 1' - 0" DETAIL AT 91 TANK TURBINE SUMP SCALE: 1/2" = 1' - 0" DETAIL AT 91 TANK FILL SUMP SCALE: 1/2" = 1' - 0" DIESEL 12K 87 12K 91 12K PLEASE SEE XERXES TANK DRAWING SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 ASSEMBLYPUMP-MOTORPETROLEUM CM FARLAND, WI 6" SUMP SENSOR AT LOWEST POINT 4" BLACK IRON RISER 45 ° STEEL STRIKER PLATES TYP. SWIVEL FILL ADAPTOR EXPLOSION PROOF J-BOX W/SEAL-OFF (TYP.) CONDUIT PENETRATION DOUBLE WALL FIBERGLASS SUMP FILL CAPMULTIPORT COVER W/ (1) 5 GALLON BUCKET WATER TIGHT SHROUD ASSEMBLY RUBBER CAP RISER ADAPTOR TO VEEDER-ROOT PANEL OVERFILL PROTECTION DROP TUBE SET AT 95% (TYP.) SUMP SENSOR AT LOWEST POINT DOUBLE WALL FIBERGLASS SUMP 4" PLUG 24 38 24 38 45 19 TO VEEDER-ROOT PANEL CONDUIT PENETRATION4 3" OVER 2" FRP TO TURBINE SUMP4241 3" OVER 2" FRP VENT PIPE4241 MINI-HYDO SENSOR 36 5" 2" SS BALL VALVE PLLD TURBINE MANHOLE COVER MINI-HYDO SENSOR ATG CONDUIT PENETRATION TO VEEDER-ROOT PANEL EXPLOSION PROOF J-BOX W/SEAL-OFF DOUBLE WALL FIBERGLASS SUMP SET AUDIBLE & VISUAL ALARM @ 90% CAPACITY 2" FLEX CONNECTOR NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION 3" OVER 2" FRP TO FILL SUMP 3" OVER 2" FRP PRODUCT LINE VAC SENSORS CONDUIT PENETRATION 12"x24"x11GA STEEL STRIKER PLATES TYP. UNDER ALL OPENINGS W/ MANWAYS ON FIBERGLASS TANK (BY TANK MANF.) TRAPPER SCREEN SUMP SENSOR AT LOWEST POINT DOUBLE WALL FIBERGLASS SUMP EXTRACTOR TEE CONDUIT PENETRATION TO VEEDER-ROOT PANEL EXPLOSION PROOF J-BOX W/SEAL-OFF TURBINE PLLD CONDUIT PENETRATION VAC SENSORS 3-WAY BALL VALVE (TYP.) 3" OVER 2" FRP PRODUCT LINE NOV FIBERGLASS SYSTEMS FRP PIPE PENETRATION 2" FLEX CONNECTOR 3"X3" FOAM SPACER PER MANUFACTURER'S SPECIFICATIONS SUMP SENSOR AT LOWEST POINT EXTRACTOR TEE BALL BLOAT SET @ 95% OF TANK CAPACITY 38 38 26 26 4 4 4 4 4241 4241 25 25 11 11 17 17 45 45 1 1 36 23 57 10 3" OVER 2" FRP TO FILL SUMP4241 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 UST & SUMP DETAILS SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/23 5669 F3-2 ALVARO CORONA SHEET F3-2 B A C D E F G H J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 SECTION THROUGH TANK AND EXCAVATION SCALE: 1/4" = 1' - 0" TURBINE FILL ANNULAR MONITOR DETAIL C - THIS SHEET 8" 4' - 0 " 8' - 0 " DE P T H T O G R O U N D W A T E R + - 2 4 ' B F G SO U R C E : A N T E A G R O U P ( 8 0 0 - 4 7 7 - 7 4 1 1 ) A 13 TANK SHALL BE INSTALLED BY XERXES TANK CERTIFIED CONTRACTOR. LEAK MONTORING SYSTEM SHALL BE INSTALLED BY VEEDER ROOT CERTIFIED CONTRACTOR. PIPING SYSTEM TO BE INSTALLED A.O. SMITH CERTIFIED CONTRACTOR. UNDER DISPENSER CONTAINMENT SUMPS SHALL BE INSTALLED BY BRAVO CERTIFIED CONTRACTOR. TESTING AND CERTIFICATION SHALL BE DONE BY AN I.C.C. CERTIFIED TECHNICIAN. 37'-2" UNDERGROUND STORAGE TANK - XERXES 2'-0" (MIN.) 8'-0" (TYP.) 2'-0" (MIN.) 8" 4' - 0 " 10 ' - 4 " 4' - 0 " 4'-0" DE P T H T O G R O U N D W A T E R + - 2 4 ' B F G SO U R C E : A N T E A G R O U P ( 8 0 0 - 4 7 7 - 7 4 1 1 ) 13 13 STEEL MANWAY (TYP.) DETAIL AT DIESEL TANK TURBINE SUMP SCALE: 1/2" = 1' - 0" DETAIL AT DIESEL TANK FILL SUMP SCALE: 1/2" = 1' - 0" DIESEL 12K 87 12K 91 12K PLEASE SEE XERXES TANK DRAWING SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 DETAILS & LIST OF EQUIPMENT SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F4-1 ALVARO CORONA SHEET F4-1 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 EQUIPMENT LEGEND NO EQUIPMENT DESCRIPTION MANUFACTURER QTY PART NUMBER 1 2" SS FLEX CONNECTOR FLEXING 14 FF20X18M346XF 2 DBL. WALL VENT TRANSITION SUMP BRAVO (AB2481) - DBL. WALL 1 B-600-F4S-BD-AB 3 SUMP ENTRY /TERMINATION FITTING A.O. SMITH 30 3" = 012030-626-0 4 CONDUIT PENETRATION FITTING BRAVO 0 F-17-RR-D 5 DBL. WALL UNDER DISPENSER SUMP BRAVO (AB2481) - DBL. WALL 5 B9000 F2L-BD-AB-EO-FRM 6 GEO-TEXTILE FILTER FABRIC TYPAR 1 3401 7 CONCENTRIC REDUCER A.O. SMITH 0 3" X 2" = 012030-238-3 8 BRASS GROUNDING ROD & CLAMPS BRAVO 4 F-17-GR 9 RESERVOIR WITH MINI SENSOR VEEDER ROOT 14 VEEDER ROOT 10 42" TURBINE MANWAY FIBERLITE 4 FL42F 11 1.5 HP SUBMERSIBLE TURBINE F.E. PERTO 4 STPRAG150VL2-24 W/CONTROLLER 12 18" MANWAY OPW 4 6110-128WT 13 DBL. WALL FRP UNDERGROUND TANK XERXES 4 (3) 15K, (1) 10K GAL. 14 5 GALLON FILL BUCKET OPW 4 1C-2100-DEVR WITH DRAIN 15 5 GALLON VAPOR BUCKET OPW 3 1C-2100-PERV 16 17 EXTRACTOR TEE ASSEMBLY OPW 4 233VM-4432 18 PRESSURE VACUUM VALVE HUSKY 1 4895 19 OVERFILL FLAPPER VALVE OPW 4 61SOM-412C-EVR 20 JACK SCREW ASSEMBLY OPW 4 61JSK-44CB-EVR 21 FUEL FILL SWIVEL ADAPTER OPW 4 61 SALP-1020EVR 22 FILL ADAPTER CAP OPW 4 634 TT -7085EVR 23 2" BALL VALVE JOMAR 4 100-708 24 42" DBL. WALL FRP SUMP W/O COVER XERXES 4 42X48 8 SIDES BRINE FILLED 25 48" DBL. WALL FRP SUMP W/COVER XERXES 4 48X48 8 SIDES BRINE FILLED 26 VACUUM SENSOR ASSEMBLY VEEDER ROOT 1 4 SENSOR KIT - MODEL #330020-471 27 DUAL POINT HYDROSTATIC SENSOR VEEDER ROOT 4 794380-303 28 2" FLOAT MAG PROBE INSTALL KIT VEEDER ROOT 4 846400-100 29 PROBE CAP AND RING KIT VEEDER ROOT 4 312020-952 30 VACUUM TUBE VEEDER ROOT 1 332310-003 31 CLEAN AIR SEPARATOR FRANKLIN FUELING SYSTEM 1 9931 (EXISTING) 32 DISPENSER (GASOLINE ONLY)GILBARCO ENCORE 700 4 ENC700SNN1 (3+1) 33 GASOLINE COAXIAL WHIP HOSE VST 8 VSTA-EVR 34 GASOLINE BREAKAWAY OPW 8 66CLP 35 8'9" GASOLINE HOSE VST 8 VDV-EVR 36 MINI HYDROSTATIC SENSOR VEEDER ROOT 14 VR794380-304 RESERVOIRS BY TANK AND SUMP MANUFACTURER 37 GASOLINE MAG UEVEL PROBE VEEDER ROOT 4 VR846390-111 38 SUMP SENSOR VEEDER ROOT 1 VR794380-208 39 42" MULTIPORT MANWAY OPW 4 6571EVRB-164042RT052 40 GASOLINE NOZZLE VST 8 VST-EVR-NB 41 2" FRP PRIMARY PIPE A.O. SMITH RED THREAD IIA 300 011020-069-1 42 3" FRP SECONDARY PIPE A.O. SMITH RED THREAD IIA 600 011030-069-4 43 3" FRP PRIMARY PIPE A.O. SMITH RED THREAD IIA 300 011030-069-3 44 4" FRP SECONDARY PIPE A.O. SMITH RED THREAD IIA 400 011040-077-6 45 EXPLOSION PROOF J-BDX APPLETON 14 GRSS75 46 CONDUIT SEAL APPLETON 20 EYS75 47 4" NPT FITTING TANK MANUFACTURER 48 PRESSURIZED LINE LEAK DETECTOR VEEDER ROOT 4 848480-001 49 ISD VAPOR FLOW METER VEEDER ROOT 4 332374 50 51 ISD SOFTWARE UPGRADE VEEDER ROOT 1 VERSION 1.05 52 VAPOR SWIVEL ADAPTER OPW 3 61VSA-1020-EVR 53 VAPOR TOP SEAL CAP OPW 6 1711T-7085-EVR 54 FACE SEAL ADAPTER OPW 6 FSA-400-S 55 ATMOSPHERIC SMART SENSOR VEEDER ROOT 1 332250-001 56 SUMP SENSOR VEEDER ROOT 14 794380-323 57 1/4" STAINLESS STEEL BALL VALVE JOMAR 1 500-099 58 3" STAINLESS STEEL FLEX CONNECTOR FLEXING 3 FF30X18F346 59 2" STAINLESS STEEL FLEX CONNECTOR FLEXING 17 FF32X18MS90 60 4X3 FRP CONCENTRIC REDUCER A.O. SMITH RED THREAD IIA 4 012040-238-3 (FOR 3” OVER 2" PIPE) 61 5X 4 FRP CONCENTRIC REDUCER A.O. SMITH RED THREAD IIA 012050-238-3 (FOR 4” OVER 3" PIPE) 62 4” PENETRATION A.O. SMITH RED THREAD IIA 2 012040-626-0 63 OVERFILL ALARM VEEDER ROOT 1 790091-001 64 ACKNOWLEDGEMENT SWITCH VEEDER ROOT 1 790095-001 65 TLS-350 MONITORING PANEL VEEDER ROOT 1 848290-022 66 SS FLEX CONNECTOR FLEXING 18 FF20X12HXMS90 67 PRODUCT SHEAR VALVE OPW 13 10P-0152 68 VAPOR SHEAR VALVE OPW 4 60VP-1001 69 PENETRATION FITTING SMITH 32 012030-626-0 70 DRAIN KIT OPW 4 1DK-2100 71 TANK BOTTOM PROTECTOR OPW 4 6111-1400 72 DROP TUBE OPW 4 61-T 73 SS FLEX CONNECTOR FLEXING 18 FF20X 12HMXMS90 NEW RED THREAD IIA PIPE LEGEND ITEM DESCRIPTION MODEL # A 2" FIBERGLASS PIPE 01102-069-2 B 3” FIBERGLASS PIPE 01103-069-2 C 4" FIBERGLASS PIPE 01104-069-2 D 4X3 CONCENTRIC REDUCER (2 PIECE)012040-283-3 E 3X2 PRIMARY FIBERGLASS REDUCER 012030-231-4 F 2" 45 DEGREE FIBERGLASS PRIMARY ELBOW 01202-310-4 G 3" PRIMARY ELBOW 012040-310-3 H 3” SECONDARY FIBERGLASS TEE (2 PIECE)01203-410-3 I 3" 45 DEGREE SECONDARY FIBERGLASS ELBOW 01203-310-3 J 4” SECONDARY FIBERGLASS TEE (2 PIECE) 0 12060-410-3 K 3" PRIMARY FIBERGLASS TEE 012030-410-4 L 4” SECONDARY ELBOW 012040-310-3 M 4" SECONDARY ELBOW 012040-310-3 (N) COAXIAL HOSE (N) BREAKAWAY (N) DISPENSER (N) COAXIAL HOSE (N) VST EVR NOZZLE NOTE: UDC INTERSTITIAL AND SENSOR RESERVOIR SHALL BE FILLED WITH BRAVO #IMI-1GAL MONITORING FLUID (PROPLYNE GLYCOL) (N) BRAVO RESERVOIR & SENSOR (N) 5/8" COPPER PIPE TO BALL VALVE AND DISPENSER VAPOR PIPING (N) VEEDER ROOT ISD PRESSURE SENSOR (N) VEEDER ROOT ISD FLOW METER (N) VAPOR SHEAR VALVE (N) VAPOR PIPE PENETRATION (N) BRAVO FIBERGLASS UNDER DISPENSER CONTAINMENT BOX (N) 3 WAY BALL VALVE (N) 1/4" TUBING NOTE: INSTALL VEEDER ROOT BALANCE ENHANCED PHASE II VAPOR RECOVERY EQUIPMENT PER EXECUTIVE ODER VR-204-Q. 91 U L (N) SUMP SENSOR (N) SS FLEX (TYP.) VA P O R (N) PRODUCT OF PIPE PENETRATION (TYP. OF 2) 87 U L 5 69 40 35 32 34 33 50 49 68 9 56 69 66 22 3/4 4 1/8 6 3/8 2 MI N I M U M C O N C R E T E 8 " 31 3 / 4 20 MI N I M U M C O N C R E T E 2 4 " OP T I O N A L EO - E B S GRADE CONCRETE PLAN PER PRODUCT INSTRUCTION, RAISE TOP OF COVER 2" ABOVE GRADE, AND SLOPE 1" DOWN AND 12" AWAY FROM THE TOP EDGE OF MIDFRAME, 360 AROUND BRAVO-CERTIFICATION REQUIRED National Test covers this product at sbravo.com/cert 3 1 / 2 23 4 38 1/2 33 1/2 251 2 C/ L E A B G H 8 C/ L E F OP T I O N A L EO - E B S FRONT VIEW FRONT VIEW TOP VIEW RIGHT SIDE VIEW E D VFA-2' ON 3' HALF NIPPLE (TYP. OF 2) BILL OF MATERIALS NO.QYT.PART DESCRIPTION A 1 FRP BOX 20Wx25-1/2Lx24-1/2D B 1 B500 MIDFRAME SMALL C 1 B500 LID SMALL D 2 VFA-2' ON 3' HALF NIPPLE E 1 OPTIONAL EO-EBS F 1 GAUGE ASSEMBLY (BOX) G 1 TUBING ASSEMBLY H 1 MANOMETER ASSEMBLY J 1 ATMOSPHERIC MANOMETER ASSEMBLY K 2 INTERSTITIAL FLUID (1 GAL.) (N) FLEX CONNECTOR (N) TRANSITION SUMP (N) SENSOR SLEEVE (N) SUMP SENSOR PENETRATION (TYP. OF 2) JOINT(N) CONCRETE (N) VENT RACK (N) 2" STEEL RISER (N) VENT MANIFOLD (N) P/V VALVE 46 36 59 2 69 45 18 NOTE: SUMP INTERSTITIAL AND SENSOR RESERVOIR SHALL BE FILLED WITH BRAVO #IMI-1GAL MONITORING FLUID (PROPLYNE GLYCOL) PLAN AT NEW VENT TRANSITION SUMP SCALE: 1" = 1' - 0"E GILBARCO SINGLE DISPENSER DETAIL [GASOLINE ONLY] SCALE: 3/4" = 1' - 0"G VENT TRANSITION SUMP NTSH NEW BRAVO FIBERGLASS UDC WITH GILBARCO ENCORE 700 S MODEL PIPE AND UDC AT DISPENSERS 1-10 SCALE: 1" = 1'-0'F 4" / 3 " V A P O R R E T U R N 3" / 2 " 9 1 U L SS FLEX CONNECTOR BELOW SHEAR VALVE (TYP.) VAPOR SHEAR VALVE FUEL DISPENSER H M F I B A B A B C ED GL KJ A 91 UL VAPOR 66 38 36 5 BRAVO UDC NOTE: UDC INTERSTITIAL AND SENSOR RESERVOIR SHALL BE FILLED WITH BRAVO #IMI-1GAL MONITORING FLUID (PROPLYNE GLYCOL) G F4 69 69 12 ' - 0 " EXISTING HEALY TANK SEE PG F3 B 3" / 2 " 8 7 U L 87 UL B A DIESEL 56 SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 DETAILS & LIST OF EQUIPMENT SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 7/19/2023 5669 F4-2 ALVARO CORONA SHEET F4-2 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 EQUIPMENT LEGEND NO EQUIPMENT DESCRIPTION MANUFACTURER QTY PART NUMBER FILL & STAGE I EQUIPMENT 74 I.D. MARKER (E85)OPW 1 1 TAG-CE85 W/ 1 TAG-BE85 75 I.D. MARKER (E85 VAPOR)OPW 1 1 TAG-7000 W/ 1 TAG-7010 76 4" FILL CAP OPW 4 634TT-7085-EVR 77 4" SWIVEL FILL ADAPTER OPW 4 61SALP-MA 78 4" VAPOR CAP OPW 3 7085-EVR 79 4" SWIVEL VAPOR ADAPTER OPW 3 1711T-61VSA-MA 80 4" FACE SEAL ADAPTERS OPW 7 EXISTING 81 OVERFILL PREVENTION OPW 4 71SOM-412C 82 RISER SUPPORT BRACKET OPW 4 6511-RB16 DISPENSER & ASSOCIATED EQUIPMENT 83 FLEXIBLE FUEL DISPENSER 3+1 W/O VAPOR VAC, W/ JUNCTION BOX OPTION, W/ CARD READER OPTIONS (BALANCE READY). GILBARCO ENCORE 700S MODEL: APRO-700S-NL1-2 84 85 86 87 88 89 1-1/2" SHEAR VALVE, DBL POPPET OPW 4 10P-0152E85 TURBINE, FLEX CONNECTORS & VALVES 90 2HP SUBMERGED TURBINE PUMP W/RISER FE PETRO 1 ISTM-2R W/ #403522924 RISER 91 TURBINE CONTROLLER FE PETRO 1 STP-DHI 92 2" STAINLESS STEEL BALL VALVE JOMAR 1 100-968 93 FLEX CONNECTOR - 2" X 24" - M X M (@TURB.)FIREFLEX 1 FF20X24HMXM346 MONITORING EQUIPMENT 94 POSITION SENSITIVE SUMP SENSOR VEEDER ROOT 13 794380-323 95 TANK LEVEL PROBE - E85 VEEDER ROOT 1 846391-608 96 MECHANICAL LINE LEAK DETECTOR FRANKLIN FUELING SYSTEM 1 403169901 STP-MLD+AG (E85) 97 4" FLOAT KIT - E85 (WITH 10' CABLE)VEEDER ROOT 1 846400-014 DISPENSER & ASSOCIATED EQUIPMENT 98 3/4" MALE X 12" GREEN HARDWALL WHIP HOSE MALE X MALE SWIVEL ENDS 2 GYG 3/4 X 1 MXMS WHIP 99 3/4" MALE X 8'-6" GREEN HARDWALL HOSE MALE X MALE SWIVEL ENDS 2 GYG 3/4 X 1 MXMS WHIP 100 3/4" MALE X 3/4" FEMALE MULTI-PLANE SWIVEL HUSKY 2 350 101 3/4" FEMALE X 3/4" FEMALE SAFE T BREAK RECONNECTABLE BREAKAWAY HUSKY 2 3360 102 GREEN LEADED/DIESEL NOZZLE WITH HOLD OPEN CLIP OPW 2 11B-0100 NOTE: INSTALL VEEDER ROOT BALANCE ENHANCED PHASE II VAPOR RECOVERY EQUIPMENT PER EXECUTIVE ODER VR-204-Q. GILBARCO DISPENSER DETAIL [GASOLINE AND DIESEL] SCALE: 3/4" = 1' - 0"G NEW BRAVO FIBERGLASS UDC WITH GILBARCO ENCORE 700 S MODEL (N) COAXIAL HOSE (N) BREAKAWAY (N) DISPENSER (N) COAXIAL HOSE (N) VST EVR NOZZLE NOTE: UDC INTERSTITIAL AND SENSOR RESERVOIR SHALL BE FILLED WITH BRAVO #IMI-1GAL MONITORING FLUID (PROPLYNE GLYCOL) (N) BRAVO RESERVOIR & SENSOR (N) 5/8" COPPER PIPE TO BALL VALVE AND DISPENSER VAPOR PIPING (N) VEEDER ROOT ISD FLOW METER (N) VAPOR SHEAR VALVE (N) VAPOR PIPE PENETRATION (N) BRAVO FIBERGLASS UNDER DISPENSER CONTAINMENT BOX (N) 1/4" TUBING 91 U L (N) SUMP SENSOR (N) SS FLEX (TYP.) VA P O R (N) PRODUCT OF PIPE PENETRATION (TYP. OF 2) 87 U L 5 69 40 35 32 34 33 49 68 9 56 69 66 DI E S E L NEW RED THREAD IIA PIPE LEGEND ITEM DESCRIPTION MODEL # A 2" FIBERGLASS PIPE 01102-069-2 B 3” FIBERGLASS PIPE 01103-069-2 C 4" FIBERGLASS PIPE 01104-069-2 D 4X3 CONCENTRIC REDUCER (2 PIECE)012040-283-3 E 3X2 PRIMARY FIBERGLASS REDUCER 012030-231-4 F 2" 45 DEGREE FIBERGLASS PRIMARY ELBOW 01202-310-4 G 3" PRIMARY ELBOW 012040-310-3 H 3” SECONDARY FIBERGLASS TEE (2 PIECE)01203-410-3 I 3" 45 DEGREE SECONDARY FIBERGLASS ELBOW 01203-310-3 J 4” SECONDARY FIBERGLASS TEE (2 PIECE) 0 12060-410-3 K 3" PRIMARY FIBERGLASS TEE 012030-410-4 L 4” SECONDARY ELBOW 012040-310-3 M 4" SECONDARY ELBOW 012040-310-3 PIPE AND UDC AT DISPENSERS 11-12 SCALE: 1" = 1'-0'F 4" / 3 " V A P O R R E T U R N 3" / 2 " D I E S E L 3" / 2 " 9 1 U L SS FLEX CONNECTOR BELOW SHEAR VALVE (TYP.) VAPOR SHEAR VALVE FUEL DISPENSER H M F I B A B A A BB C ED GL KJ A A 91 UL DIESEL VAPOR 38 36 5 BRAVO UDC NOTE: UDC INTERSTITIAL AND SENSOR RESERVOIR SHALL BE FILLED WITH BRAVO #IMI-1GAL MONITORING FLUID (PROPLYNE GLYCOL) G F4 69 69 69 B B 3" / 2 " 8 7 U L 87 UL B A SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 CALL TOLL FREE 1 (800) 227-2600 TWO WORKING DAYS BEFORE YOU DIG REVISIONS NO.DATE DESCRIPTION NO.DATE DESCRIPTION CONTRACTOR: CORONA CONSTRUCTION CO. 615 E. ALLEN AVE. SAN DIMAS, CA 91773 PHONE: 626-926-7487 CA. LIC. #797455 CLASS A-B-HAZ C10 EXPIRES 07/31/2025 SHORING DETAILS SITE ADDRESS: UNITED PACIFIC #5669 1913 WEST EDINGER AVE. SANTA ANA, CA 92704 SCALE: DRAWN BY: DATE: JOB NO. DRAWING NO. CHECKED BY: AS NOTED ETHAN BUI 5/14/2024 5669 F10 ALVARO CORONA SHEET F10 B A C D E F G H I J B A C D E F G H I J 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L ICENSED CONTRACTOR STATE OF CAL IFORNIA CORONA CONSTRUCTION CO. 797455 EXPIRES 07/31/2025 SIGNED 5/14/24 1913 W Edinger Ave - 101118671 & 201824107/2/2024 APRO, LLC DBA UNITED PACIFIC SOUTHERN CA OFFICE: 4130 Cover Street • Long Beach, California • 90808 • Telephone: 310-323-3992 To: Orange County Health Care Agency Attn: Permits/Licensing Department From: APRO, LLC dba United Oil & United Pacific Date: August 2, 2023 RE: Authorization for Vendor to Permit & Perform Line and UST Replacement: United #5669 (CERS ID 1039729) 1913 W Edinger Avenue Santa Ana, CA 92704 To Whom It May Concern: Please allow this letter to serve as APRO, LLC authorization to allow our company’s vendor, “CORONA CONSTRUCTION, INC” to obtain a permit and perform “Line and Underground Storage Tank (UST)” replacement at our gas station site (“5669”) referenced above. APRO, LLC owns the underground storage tanks at this Station. If you should have any questions, please contact me at (310) 930-5415. Thank you. Sincerely, Tom M. Robins Staff Geologist / Environmental Specialist United Pacific 4130 Cover Street Long Beach, CA 90808 P: (310) 323-3992; 2012 C: (310) 930-5415 1913 W Edinger Ave - 101118671 & 201824107/2/2024 Facility/Site United 5669 CERS ID 10397629 Santa Ana, CA 92704 1913 W Edinger Ave Property Owner CF UNITED PROPCO LLC (310) 323-3992 Long Beach, CA 90808 4130 Cover Street Type of Action Confirmed/Updated Information Tank Owner APRO LLC (925) 884-0800 Long Beach, CA 90808 4130 Cover Street Non-Government Tank Owner Type Facility Information United 5669 1913 W Edinger Ave Santa Ana, CA 92704 44040092 Board of Equalization Account Number Motor Vehicle Fueling Facility Type No Is the facility located on Indian Reservation/Trust lands? Tank Operator APRO LLC (310) 323-3992 Long Beach, CA 90808 4130 Cover Street Permit Holder Information Facility Operator Permit Holder Notification Information Supervisor of Division, Section, or Office (Required for Public Agencies Only) Financial Responsibility Mechanism(s) Indicate which approved mechanism(s) are being used to show financial responsibility either as contained in the federal regulations (40 CFR, Part 280, Subpart H, Sections 280.93 through 280.107) or CCR, Title 23, Division 3, Chapter 18, Section 2808.1. Self-Insured Guarantee Insurance Yes Exemption Letter of Credit Surety Bond Local Government Mechanism State Fund and CD State Fund and CFO Letter Other Mechanism Submittal Status Comments by submitter: uploaded MC for 2023 This was a Draft submittal as of 8/2/2023; Last updated by Atlas Environmental on 7/17/2023 3:48 PM California Environmental Reporting System (CERS)Underground Storage Tank - Facility Information Printed on 8/2/2023 5:58 AM 1913 W Edinger Ave - 101118671 & 201824107/2/2024 Monitoring System Certification UST Site Plan site Address: UN|TED #5669 1913 W EDTNGER AVENUE, SANTA ANA, CA 92704 -,-. -+ :l SO :*. i- 'lr' .{ L6 .- -YV99 ,L2 'vR2ob.: H F. ri-. ,-,-rr' . . VB2PB, ip ntr-o l>:'-1 PETRO /:S , Ii F 'it i208 r - ,l I FE PETRO S TP MI.t).i-----HJ-,,-g do -t VR2OB 'l o o Date map was drawn: _l _.lJ_, I nstru ciionq If you already have a diagrarn that shows all required inlbrmation, you may include it, rather than this page, with your Monitoring System Certification, On your site plan, show the genelal layout ol tanks and piping. Clearly identify locations of the following equipmetrt, if installed: rnonitoring system conhol panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spi1l containers, or other secondary containment areas; mechanical or elecffonic line leak detectors; and in-tank liquid ievel probes (if used fbr leak detection), In the space plovided, note the date this Site Plan was prepared, vA:oR . FILL' c (D ol*'f1* : . TURBINE, *nI'l?*: El ''VENT. O. @o .t,:'19 . ,ATG oul'uli,,- -J I i"y l: F T) 87 '7 1913 W Edinger Ave - 101118671 & 201824107/2/2024 1913 W Edinger Ave - 101118671 & 201824107/2/2024 1913 W Edinger Ave - 101118671 & 201824107/2/2024 E09318CA Page 1 of 13 112016 ed. Effective date of this Endorsement: 01-Jul-2019 This Endorsement is attached to and forms a part of Policy Number: W27DD0190101 Syndicates 623/2623 at Lloyd’s Referred to in this endorsement as either the “Insurer” or the “Underwriters” ENDORSEMENT OF INSURANCE TO DEMONSTRATE FINANCIAL RESPONSIBILITY FOR STORAGE TANKS STATE OF CALIFORNIA Beazley “ECLIPSE” ENVIRO COVERED LOCATION INSURANCE POLICY – SITE ENVIRONMENTAL Name: Apro, LLC Address: 4130 Cover St., Long Beach, CA 90808 Policy Number: W27DD0190101 Period of Coverage: July 01, 2019 to July 01, 2024 Name of Insurer: Syndicate 2623/623 at Lloyd’s of London Address of Insurer: 30 Batterson Park Drive, Farmington, CT 06032 Name of Insured: Apro, LLC Address of Insured: 4130 Cover St., Long Beach, CA 90808 Certification: 1. The Insurer, as identified above, hereby certifies that it has issued liability insurance covering the following underground storage tank(s): SEE TANK LIST BELOW for taking corrective action and compensating third parties for bodily injury and property damage caused by accidental releases in accordance with and subject to the limits of liability, exclusions, conditions, and other terms of the policy arising from operating the underground storage tank(s) identified above. The limits of liability are $1,000,000 "each occurrence" and $2,000,000 "annual aggregate", exclusive of legal defense costs. This coverage is provided under Policy Number W27DD0190101. The effective date of said policy is 01-Jul-2019. 2. The Insurer further certifies the following with respect to the insurance described in paragraph 1: a. Bankruptcy or insolvency of the insured shall not relieve the Insurer of its obligations under the policy to which this certificate applies. b. The Insurer is liable for the payment of amounts within any deductible applicable to the policy, to the provider of corrective action or a damaged third-party, with a right of reimbursement by the insured for any payment made by the Insurer. This provision does not apply with respect to that 1913 W Edinger Ave - 101118671 & 201824107/2/2024 E09318CA Page 2 of 13 112016 ed. amount of any deductible for which coverage is demonstrated under another mechanism or combination of mechanisms as specified in 40 CFR 280.95-280.102. c. Whenever requested by a Director of an implementing agency, the Insurer agrees to furnish to the Director a signed duplicate original of the policy and all endorsements. d. Cancellation or any other termination of the insurance by the Insurer, except for non-payment of premium or misrepresentation by the insured, will be effective only upon written notice and only after the expiration of 60 days after a copy of such written notice is received by the insured. Cancellation for non-payment of premium or misrepresentation by the insured will be effective only upon written notice and only after expiration of a minimum of 10 days after a copy of such written notice is received by the insured. e. The insurance covers claims otherwise covered by the policy that are reported to the Insurer within six months of the effective date of cancellation or non-renewal of the policy except where the new or renewed policy has the same retroactive date or a retroactive date earlier than that of the prior policy, and which arise out of any covered occurrence that commenced after the policy retroactive date, if applicable, and prior to such policy renewal or termination date. Claims reported during such extended reporting period are subject to the terms, conditions, limits, including limits of liability, and exclusions of the policy. I hereby certify that the wording of this instrument is identical to the wording in 40.CFR 280.95-280.102 and that the Insurer is licensed to transact the business of insurance, or eligible to provide insurance as an excess or surplus lines insurer, in one or more states. _____________________________________________ Signature of authorized representative of Insurer Douglas Colosky Head of US Operations, Authorized Representative of Lloyd’s Syndicate 623/2623 30 Batterson Park Road, Farmington, CT 06032 1913 W Edinger Ave - 101118671 & 201824107/2/2024 10293154 UNITED #5647 105 S VINCENT AVE WEST COVINA 91790 10342927 UNITED #5651 250 Tiburon Boulevard TIBURON 94920 10483006 UNITED #5654 5201 W 1st St SANTA ANA 92703 10343089 UNITED #5662 100 Marinwood Avenue SAN RAFAEL 94903 10397344 UNITED #5665 475 W Colorado St GLENDALE 91204 10397347 UNITED #5666 6322 Westminster Blvd WESTMINSTER 92683 10397629 UNITED #5669 1913 W Edinger Ave SANTA ANA 92704 10427509 UNITED #5670 727 S EAST ST ANAHEIM 92805 10346890 UNITED #5671 1640 N MILPITAS BL MILPITAS 95035 10397632 UNITED #5681 2756 N Tustin St ORANGE 92865 10397635 UNITED #5686 1401 Munras Ave MONTEREY 93940 10293136 UNITED #5695 551 N SUNSET AVE LA PUENTE 91744 10200811 UNITED #5696 1445 Channel Islands Blvd.OXNARD 93033 10638727 UNITED #5698 200 Milpas St SANTA BARBARA 93103 10326694 UNITED #5699 19995 Indian Ave NORHT PALM SPRIN 92258 10254148 UNITED #5701 8525 S SEPULVEDA BLVD UN A LOS ANGELES 90045 10392004 UNITED #5703 17011 W BERNARDO DR SAN DIEGO 92127 10253086 UNITED #5706 304 N VERMONT AVE LOS ANGELES 90004 10293157 UNITED #5710 1696 AZUSA AVE INDUSTRY 91748 10293163 UNITED #5730 28203 DOROTHY DR AGOURA 91301 10167951 UNITED #5734 2950 AUTOMALL PKWY FREMONT 94536 10037641 UNITED #5736 2525 S ARCHIBALD AVE ONTARIO 91761 10397638 UNITED #5737 13724 Bear Valley Rd VICTORVILLE 92392 10397644 UNITED #5742 32611 Niguel Rd DANA POINT 92629 10188701 UNITED #5748 6401 DUBLIN BLVD DUBLIN 94568 10405735 UNITED #5749 1801 Santa Rita Rd PLEASANTON 94566 10223287 UNITED #5754 191 IRON POINT RD FOLSOM 95630 10167957 UNITED #5760 34867 ARDENWOOD BLVD FREMONT 94555 10412320 UNITED #5764 5630 E 7th St LONG BEACH 90804 10326568 UNITED #5793 41010 California Oaks Rd Murrieta 92562 10412323 UNITED #5945 4760 Irvine Blvd IRVINE 92620 10204264 UNITED #7237 4047 SOUTH SHINGLE RD SHINGLE SPRINGS 95682 10007185 UNITED #7240 8998 ALCOSTA BLVD SAN RAMON 94583 10363162 UNITED #7953 481 SWEETWATER RD SPRING VALLEY 91977 10357399 UNITED #7961 1666 ALPINE BLVD ALPINE 91901 10037608 UNITED #7963 4125 PHELAN RD PHELAN 92371 10360627 UNITED #7964 8899 LA MESA BLVD LA MESA 91941 10326460 UNITED #7965 80980 Highway 111 INDIO 92201 10202494 UNITED #7966 2650 CAMERON PARK Dr CAMERON PARK 95682 10219888 UNITED #7968 6500 MACK RD SACRAMENTO 95823 10253968 APRO Distribuition # 35 270 S Western Ave LOS ANGELES 90004 10254067 APRO Distribuition # 49 6101 W Olympic Blvd LOS ANGELES 90048 10632370 Long Beach Travel Center 1666 W Pacific Coast Highway LONG BEACH 90810 1913 W Edinger Ave - 101118671 & 201824107/2/2024 z^ EK ,16758&7,216 25$1*( &2817< ),5( $87+25,7< 3ODQ6XEPLWWDO&ULWHULD &200(5&,$/SURMHFWV08/7,)$0,/<5(6,'(17,$/SURMHFWV DQG5(6,'(17,$/75$&7GHYHORSPHQWV )LOOLQWKHSURMHFWEXVLQHVVDGGUHVVDQGSURYLGHDEULHIGHVFULSWLRQRIWKHVFRSHRIZRUNDQGW\SHRIEXVLQHVVRSHUDWLRQWKDWZLOOWDNHSODFH $QVZHUTXHVWLRQVWKURXJKUHDGDQGLQLWLDOLWHPVDQGWKHQFRPSOHWHDQGVLJQWKHFHUWLILFDWLRQVHFWLRQ ,I\RXDQVZHU³<(6´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¶IURPD'LYLVLRQRI2LO*DVDQG*HRWKHUPDO5HVRXUFHV '2**5 ILHOGERXQGDU\¶IURP DQRLOJDVVHHSRU¶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¶ ¶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ŶŝƚŝĂůƐFRQWUDFWRUWRGHWHUPLQHLIPRGLILFDWLRQLVQHHGHGLIVRFRQWUDFWRUVKDOOVXEPLWSODQVSULRUWRPDNLQJPRGLILFDWLRQV  )LUH+D]DUG6HYHULW\=RQH&RQVXOWPDSVDYDLODEOHDWEXLOGLQJGHSDUWPHQWRURQ2&)$ZHEVLWHWRGHWHUPLQHLI\RXUVLWHLVORFDWHG LQD)+6=%XLOGLQJVLQD)+6=PD\EHVXEMHFWWRVSHFLDOFRQVWUXFWLRQUHTXLUHPHQWVGHWDLOHGLQ&%&&KDSWHU$RU&5&5² /ŶŝƚŝĂůƐWKHEXLOGLQJGHSDUWPHQWZLOOGHWHUPLQHVSHFLILFUHTXLUHPHQWV ,FHUWLI\XQGHUSHQDOW\RISHUMXU\XQGHUWKHODZVRIWKH6WDWHRI&DOLIRUQLDWKDWWKHDERYHLVWUXH 3ULQW1DPH 6LJQDWXUH 3KRQH1XPEHU; Ϳ 'DWHͬͬ %XLOGLQJ'HSDUWPHQW,I\RXKDYHYHULILHGWKDWDOORIWKHTXHVWLRQVKDYHEHHQDQVZHUHGDFFXUDWHO\DV³12´DQGWKHSURMHFWGRHVQRWRWKHUZLVHUHTXLUH2&)$ UHYLHZRIVSULQNOHURUDODUPSODQV WKHQ\RXPD\DFFHSWWKLVVLJQHGIRUPDVDZULWWHQUHOHDVHWKDW2&)$UHYLHZLVQRWUHTXLUHG6KRXOG\RXVWLOOUHTXLUHWKDWWKH DSSOLFDQWKDYHSODQVDSSURYHGE\2&)$SOHDVHLQLWLDOKHUH RUDWWDFKDQ2&)$UHIHUUDOIRUPDQGKDYHWKHDSSOLFDQWVXEPLWWKHIRUPDORQJZLWKWKH DSSURSULDWHSODQVDQGIHHVIRU2&)$UHYLHZϭϬͲϬϴͲϭϰ KD d d ͬͬ VWUX 1913 W Edinger Ave ✔ Replace underground storage tanks at gas station. ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Tone Bui 626 862-8663 03 08 2024 Santa Ana 1913 W Edinger Ave - 101118671 & 201824107/2/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS: … No further action required on this specific plan type, based on information provided on: ____/______/______. … Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ Updated: 06/02/2020 rs 1913 W Edinger Ave - 101118671 & 201824107/2/2024 ��etion Co. 615 E. Allen Ave. • San Dimas • CA • 91773 • • (626) 926-7487 • fax (626) 205-9278 License#: 797455 I am properly licensed as required by the State of California, and hereby authorize Thong Bui to act on my behalf in obtaining permits and to sign permit applications for me. Company Name: Alvaro Corona Construction Company, Inc. DBA Corona Construction Company B��Alvaro Corona =icensed Contractor ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validitv of that document. State of California / � County of _ 0� � � before me, .........._._._1-'-. -�-'Ct(-'-�--·---_N--'�+--''----­(insert name and title of the offic personally appe ared ---- J/ 0 ttJ f (} 'fl...-4_who proved to me on the basis of satisfactory evidence to be the_ �on ) whose name�1;,t ebscribed to the within instrument and acknow�ed ed �o me tha�/t �lt!)eY executed the same in 'tr��ir authorized capacity(i�, and that b i ¥rl�r signature�"on the instrument thesonr'• or the entity upon be h�lf of which the rso?fS} acted, executed the instrument. I certify under PENAL TY OF PERJURY under the Jaws of the State of California that the foregoingparagraph is tru e and correct. WITNESS my hand and official seal. Signature")/� (Seal) 1913 W Edinger Ave - 101118671 & 201824107/2/2024 Rev: 02/01/2023 Page 1 of 2 DISABLED ACCESS COMPLIANCE ACC-01 CBC 2022 A. PURPOSE OF THIS DOCUMENTATION: (check one) Finding of unreasonable hardship for projects UNDER the valuation threshold* Finding of unreasonable hardship for projects OVER the valuation threshold* Certification of Full Compliance with the 2022 California Building Code * Valuation threshold as defined in the 2022 California Building Code, Section 11B-202.4 (Exception #8) and Section 202 is $195,358.00 (as of January 2023) B. PROJECT INFORMATION TO BE COMPLETED BY PETITIONER: Project Address: $ $ 1. The cost of all construction contemplated in the determination of the valuation of improvement threshold based on the valuation of site and building improvements for the last three-year period. 2. 20% of Total Construction Cost or Project Valuation: $ 3. The actual amount to be spent to provide disabled access: $ 4. Describe the impact of the proposed improvements on financial feasibility of the project. 5. Describe the proposed improvements related to accessibility upgrades on this project. Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1913 W. Edinger Ave., Santa Ana, CA 92704 Replace (e) underground storage tanks 101118671 & 20182410 My Goods Market #5669 350,000 (310) 323-3992 APRO, LLC dba United Oil & United Pacific (310) 323-3992 N/A N/A N/A N/A 70,000 N/A SCOPE OF WORK NOT TO AFFECT EXISTING ACCESSIBLE PATH OF TRAVEL SCOPE OF WORK NOT TO AFFECT EXISTING ACCESSIBLE PATH OF TRAVEL 1913 W Edinger Ave - 101118671 & 201824107/2/2024 6. Identify the accessibility features and equivalent facilities that WILL be brought into compliance with the latest edition of Title 24 as a part of this project and an estimate of the cost of each item: (Documentation may be required) Accessible Features to be Made Accessible Cost of Improvement a. Entrance: Door Landing Stairway/Steps Ramp $ b. Path of Travel: Path of travel from accessible parking to the building entrance and area of remodel $ $ Path of travel from the public way to the building entrance $ c. Sanitary facilities ( Floor no. ) $ d. Public phone(s) $ e. Drinking fountain(s) $ f. Parking $ g. Signage & Alarms $ i. Other: $ Total: $ 7. Identify the accessibility features that WILL NOT comply if a request for unreasonable hardship is granted. Provide an estimated cost of compliance for each item: (Documentation may be required) Accessible Features Not to be Improved Cost of Improvement a. $ b. $ c. $ Total: $ 8. Petitioner must be the legal property owner or his/her legal representative: I certify that the above noted information is true and correct. Legal Property Owner Architect/Engineer Contractor Other: Print Name: Phone No. Address: Signature: Date: FOR AGENCY USE ONLY Approved by: Date: N/A N/A Tone Bui (626) 862-8663 615 E Allen Ave., San Dimas, CA 91773 5/14/24 Agent for G.C. 1913 W Edinger Ave - 101118671 & 201824107/2/2024