Loading...
HomeMy WebLinkAboutFLOOD ZONE - 5121 W Roberts Dr & #2 - PlanA ACCES ACCESSORY ACOUS ACOUSTIC(AL) AFF ABOVE FINISHED FLOOR AL ALUMINUM ALT ALTERNATE ANNUNC ANNUNCIATOR ANOD ANODIZED APPL APPLIANCE ARCH ARCHITECT(URAL) AUTO AUTOMATIC AVG AVERAGE & AND B BLDG BUILDING BOLLD BOLLARD BD BOARD BLKG BLOCKING BRDLM BROADLOOM BU BUILT UP C CAB CABINET CPT CARPET CEM CEMENT(ITIOUS) CER CERAMIC CLG CEILING COATG COATING COILG COILING CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS(ATION) CONTR CONTRACT(OR) COV COVER CMU CONCRETE MASONRY UNIT D DBL DOUBLE DEPT DEPARTMENT DES DESIGN(ED) DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN $ DOLLAR (US CURRENCY) DR DOOR DSCON DISCONNECT DWR DRAWER E ELAST ELASTOMERIC ELEC ELECTRICAL EMBED EMBEDD(ED)(ING) ENGR ENGINEER(ED) ENTR ENTRANCE EQ EQUAL EQUIP EQUIPMENT EXIST EXISTING EXP JT EXPANSION JOINT EXPS EXPOSE(D) EXT EXTERIOR F FAB FABRICATION FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER AND CABINET FHC FIRE HOSE CABINET FIN FINISH FLDG FOLDING FPLC FIREPLACE FR FIRE RAT(ING)(ED) FRMG FRAMING FXD FIXED FXTR FIXTURE FLR FLOOR(ING) FURN FURNITURE FWC FABRIC WALL COVERING G GA GAUGE GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS FIBER REINFORCED GYPSUM GFRP GLASS FIBER REINFORCED PLASTER GL GLASS GR GRAD(E)(ING) GYP GYPSUM H HD HEAD HDWD HARDWOOD HDWE HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING, VENTILATING, AND AIR CONDITIONING I INFO INFORMATION INSTRUM INSTRUMENT(ATION) INSUL INSULATION INTLK INTERLOCK(ING) INT INTERIOR INFILTR INFILTRATION J JAN JANITOR K KIT KITCHEN L LAV LAVATORY LB POUND £ BRITISH POUND (CURRENCY) LT LIGHT LVLG LEVELING LVR LOUVER M MAX MAXIMUM MFD MANUFACTURED MFR MANUFACTURER MECH MECHANICAL MET METAL MEMB MEMBRANE MEZZ MEZZANINE MIN MINIMUM MISC MISCELLANEOUS MLWK MILLWORK MOIST MOISTURE MOT MOTOR(IZED) MTD MOUNTED N NIC NOT IN CONTRACT NO NUMBER NTS NOT TO SCALE O ORNA ORNAMENTAL OVFL OVERFLOW OVHD OVERHEAD OPNG OPENING(S) OPR OPERABLE P PTN PARTITION PEDTR PEDESTRIAN PBD PARTICLE BOARD PNL PANEL POLYST POLYSTYRENE PORT PORTABLE PREFIN PREFINISHED PREFAB PREFABRICATED PLAM PLASTIC LAMINATE PLAS PLASTER PLSTC PLASTIC PLYWD PLYWOOD PRTECN PROTECTION R RDR READER RECES RECESSED RECPT RECEPTACLE REF REFER(ENCE) REFL REFLECTED REFR REFRIGERATOR REQD REQUIRED RESIS RESIST(ANT)(IVE) REINF REINFORCE(D)(ING)(MENT) RESIL RESILIENT RFG ROOFING RM ROOM RO ROUGH OPENING S SCR SCRIBE SECUR SECURITY SF SQUARE FEET SGL SINGLE SHORG SHORING SIM SIMILAR SST STAINLESS STEEL STD STANDARD STL STEEL STRFR STOREFRONT STRUCT STRUCTURAL SURF SURFACE SUSP SUSPENDED SYS SYSTEM(S) T THK THICK TLT TOILET TRAF TRAFFIC TRANS TRANSPARENT TRTD TREATED T&G TONGUE AND GROOVE TYP TYPICAL U UNDRLAY UNDERLAYMENT UTIL UTILITY UNO UNLESS NOTED OTHERWISE V VEH VEHICLE VERT VERTICAL VIF VERIFY IN FIELD W W/ WITH WC WATER CLOSET WD WOOD WDW WINDOW W/O WITHOUT WT WEIGHT WTRPRF WATERPROOFING OWNER: 5121 W Roberts Dr. Santa Ana, CA 92704 Contact: LAM TRAN Phone: 949. 337. 5292 Email: proselytus@gmail.com ABBREVIATIONS ABBREVIATIONS (CONT.) PROJECT INFORMATION DRAWING INDEX PROJECT TEAM ARCHITECTURAL LEGENDS REVISION EQUIPMENT SYMBOL KEYNOTE DOOR NUMBER / FINISH TYPE WINDOW SYMBOL PLAN NORTH GRID OR COLUMN LINE DIMENSION FINISH ELEVATION ELEVATION CENTER LINE FACE DIMENSION CENTER LINE SECTION NUMBER PORTION OF PLAN SHOWN MATCH LINE DRAWN SHEET WHERE SHEET WHERE DRAWN ELEVATION NUMBER INTERIOR ELEVATION: SHEET WHERE DRAWN SECTION: DETAIL: DETAIL NUMBER A WALL TYPE FLUSH FINISH MATERIALS ENGINER OF RECORD / STRUCTURAL ENGINEER: PROJECT DESIGNER: VICINITY MAP ALL CONSTRUCTION SHALL CONFORM TO ALL GOVERNING LAWS, CODES AND ORDINANCES INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. TITLE 24 OF THE CALIFORNIA ADMINISTRATIVE CODE, THE 2022 CBC 2. 2022 CALIFORNIA ELECTRICAL CODE 3. 2022 CALIFORNIA MECHANICAL CODE 4. 2022 CALIFORNIA PLUMBING CODE 5. 2022 CALIFORNIA FIRE CODE 6. 2022 CALIFORNIA ENERGY CODE 7. 2022 CALIFORNIA GREEN CODE 8. 2022 CALIFORNIA RESIDENTIAL CODE 9. CITY OF SANTA ANA MUNICIPAL CODE CODE / AGENCIES CONFORMANCES BUILDING STORIES: PROJECT ADDRESS: ASSESSOR'S PARCEL NO.: ZONING : FRONT YARD: 20' REAR SETBACK: 10' 5121 W ROBERTS DR. SANTA ANA CA 92704 5121 W ROBERTS DR. #2 SANTA ANA CA 92704 R-1 R-3/U (MAIN HOUSE) & R-3 (ADU)OCCUPANCY TYPE : CONSTRUCTION TYPE : 188 062 27 1 LOT NO.: SETBACKS: PROJECT SCOPE OF WORK CONSTRUCTION MEANS CONSTRUCTING, CLEARING, GRADING OR EXCAVATION THAT RESULT IN SOIL DISTURBANCE. CONSTRUCTION INCLUDES STRUCTURE TEARDOWN (DEMOLITION). IT DOES NOT INCLUDE ROUTINE MAINTENANCE TO MAINTAIN ORIGINAL LINE AND GRADE, HYDRAULIC CAPACITY, OR ORIGINAL PURPOSE OF FACILITY; EMERGENCY CONSTRUCTION ACTIVITIES REQUIRED TO IMMEDIATELY PROTECT PUBLIC HEALTH AND SAFETY; INTERIOR REMODELING WITH NO OUTSIDE EXPOSURE OF CONSTRUCTION MATERIAL OR CONSTRUCTION WASTE TO STORM WATER; MECHANICAL PERMIT WORK; OR SIGN PERMIT WORK. 1. ERODED SEDIMENTS AND POLLUTANTS SHALL BE RETAINED ON SITE AND SHALL NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE OR WIND. 2. STOCKPILES OF EARTH AND OTHER CONSTRUCTION-RELATED MATERIALS SHALL BE COVERED AND/OR PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY WIND OR WATER. 3. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND SHALL NOT CONTAMINATE THE SOIL NOR THE SURFACE WATERS. ALL APPROVED TOXIC STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF PROPERLY AND SHALL NOT BE WASHED INTO THE DRAINAGE SYSTEM. 4. NON-STORM WATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING AND ANY OTHER ACTIVITY SHALL BE CONTAINED ON THE PROJECT SITE. 5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTE ON-SITE UNTIL IT CAN BE APPROPRIATELY DISPOSED OF OR RECYCLED. 6. TRASH AND CONSTRUCTION -RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF STORM WATER AND DISPERSAL BY WIND. 7. SEDIMENTS AND OTHER MATERIALS SHALL NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE STREET/PUBLIC WAYS. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR BY ANY OTHER MEANS. 8. RETENTION BASINS OF SUFFICIENT SIZE SHALL BE PROVIDED TO RETAIN STORM WATER RUNOFF ON-SITE AND SHALL BE PROPERLY LOCATED TO COLLECT ALL TRIBUTARY SITE RUNOFF. 9. WHERE RETENTION OF STORM WATER RUNOFF ON-SITE IS NOT FEASIBLE DUE TO SITE CONSTRAINTS, RUNOFF MAY BE CONVEYED TO THE STREET AND THE STORM DRAIN SYSTEM PROVIDED THAT AN APPROVED FILTERING SYSTEM IS INSTALLED AND MAINTAINED ON-SITE DURING THE CONSTRUCTION DURATION. STORM WATER POLLUTION CONTROL ARCHITECTURAL A00.00 DRAWING INDEX, VICINITY MAP, LOCATION MAP & PROJECT INFORMATION, GRAPHICS SYMBOLS, ABBREVIATIONS A00.50 EXISTING/DEMOLITION STITE PLAN - SITE PLANS A00.51 SITE DRAINAGE PLAN A01.00 EXISTING / DEMOLITION FLOOR PLAN & ROOF PLAN A02.00 PROPOSED FLOOR PLANS MAIN HOUSE A02.01 PROPOSED FLOOR PLANS ADU A03.00 ELECTRICAL / LIGHTING PLANS MAIN HOUSE A03.01 ELECTRICAL / LIGHTING PLANS ADU A05.00 PROPOSED ROOF PLAN MAIN HOUSE A05.01 PROPOSED ROOF PLAN ADU A08.00 EXTERIOR ELEVATIONS MAIN HOUSE A08.01 EXTERIOR ELEVATIONS ADU A09.00 BUILDING SECTIONS - MAIN HOUSE ADDITION A12.00 WALL, ROOF, DOOR & WINDOW DETAILS d2b group 11881 Comstock Rd. Garden Grove, CA 92840 Contact: MAX NGUYEN Phone: 714. 651. 9945 Email: max@d2bgroup.com DONG ENGINEERING INC. 12682 Hoover St. Garden Grove, CA 92841 Contact: TRUONG DONG Phone: 714. 204. 2874 Email: troy@dongengineering.com BUS STOP DISTANCE STRUCTURAL S0 STRUCTURAL GENERAL NOTES S.1 MAIN HOUSE - FOUNDATION & ROOF FRAMING PLANS S.2 ADU - FOUNDATION & ROOF FRAMING PLANS SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS SD3 STRUCTURAL DETAILS ENERGY EFFICIENCY T24.1 TITLE 24 MAIN HOUSE T24.2 TITLE 24 ADU T24.3 TITLE 24 CONT. SIDE SETBACK: 5' 4' MAIN HOUSE ADU 4' V-B, NON SPRINKLERED MAIN SFD- NON SPRINKLERED - MAIN HOUSE ADDITION 264 S.F. CONSISTS BEDROOM & BATHROOM. - DETACHED ADU 1,000 S.F WITH 2 BEDROOMS, 2 BATHROOMS, LIVING AREA AND SEPARATE ENTRY. - DEMO EXISTING STORAGE SHED ON EAST SIDE OF MAIN HOUSE. - LEGALIZE 3 TON CENTRAL AC FOR MAIN HOUSE. - DEMOLISH 220 METAL COVERED PATIO AND CONSTRUCT NEW COVERED PATIO. - LEGALIZE WINDOW REPLACEMENT WITH NEW OF MAIN HOUSE. PROJECT STATISTIC SITE COVERAGE SITE AREA MAIN HOUSE STRUCTURE AREA 1,758 SQ. FT. 100 %8,063 SQ. FT. 34.7 % 35 % MAX. ALLOWABLE 2,800 SQ. FT.TOTAL COVERED AREA MAIN HOUSE PROPOSED ADU (E) LIVING AREA 1,094 SQ. FT. 1,000 SQ. FT. AREA CALCULATION NEW ADDITION 400 SQ. FT. TOTAL 1,758 SQ. FT. GRAND TOTAL BOTH BLDG. 2,800 SQ. FT.1,042 SQ. FT. (E) GARAGE 264 SQ. FT. (N) ADU 1,000 SQ. FT. DIG ALERT (811) IS TO BE CONTACTED AND THAT COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING PLACE. OWNER'S SIGNATURE: DATE: DIG ALERT NOTE SEPARATE REVIEW & PERMIT A PV SOLAR SYSTEM IS REQUIRED AND SHALL BE SUBMITTED UNDER SEPARATE PERMIT. THE PV SYSTEM SHALL BE APPROVED AND INSTALLED PRIOR TO FINAL INSPECTION OF THE DWELLING. PV IS DEFERRED APPROVAL AND BUILDING CANNOT BE OCCUPIED UNTIL PV IS APPROVED BY CITY. NEW PORCH 42 SQ. FT. (N) PORCH 42 SQ. FT. 2 YES (THIS PROPERTY IS PARTIALLY LOCATED IN FLOOD ZONE - 18' OF NORTH PROPERTY) FLOOD ZONE : A09.01 BUILDING SECTIONS - ADU 1,000 SQ. FT. ADU / 1,094 SQ.FT. SFD = 0.91% MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. THE BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS REVISIONS REQUIRED BY ANY NON-CITY UTILITY COMPANY. IT IS SOLELY ON THE CONTRACTOR TO ENSURE PROPOSED ADDITION OR ALTERATION CAN AND WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 c o m s t o c k r o a d g a r d e n g r o v e C A 9 2 8 4 0 T: 7 1 4 . 6 5 1 . 9 9 4 5 E: d e s i g n 2 b u i l d @ y a h o o . c o m 06/27/2024 2 2 Bldg #101119306-07 APPROVALS: PLNG - F. Arias BLDG - J. Lo POLICE - B. Martin PUBLIC WORKS - B. Sarlak FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1 1 PR O P E R T Y L I N E 1 3 4 . 6 0 ' 4' A D U S I D E S E T B A C K PR O P E R T Y L I N E 1 3 4 . 6 0 ' 4' A D U S I D E S E T B A C K PROPERTY LINE 60' 4' ADU REAR SETBACK PROPERTY LINE 60' 5121 W Robert Dr. Santa Ana (E)POWER POLE (E) 6'H. BLOCK WALL (E ) 6 ' H . B L O C K W A L L (E ) 6 ' H . B L O C K W A L L 5' SCE EASEMENT 6' PACIFIC TELEPHONE AND TELEGRAPH EASEMENT EX I S T I N G W A T E R L I N E OF M A I N H O U S E EX I S T I N G 4 " SE W E R L A T E R A L W/H 2 2 3 4 5 6 7 7 7 8 9 11 13 14 15 15 10 24 27 2 13 874 SQ. FT. OPEN AREA RE F . ENTRY 200 AMP W/H ADDITION: 264 S.F. PR O P E R T Y L I N E 1 3 4 . 6 0 ' 4' A D U S I D E S E T B A C K PR O P E R T Y L I N E 1 3 4 . 6 0 ' 4' A D U S I D E S E T B A C K PROPERTY LINE 60' 4' ADU REAR SETBACK PROPERTY LINE 60' 5121 W Robert Dr. Santa Ana (E)POWER POLE (E) 6'H. BLOCK WALL (E ) 6 ' H . B L O C K W A L L (E ) 6 ' H . B L O C K W A L L 5' SCE EASEMENT 6' PACIFIC TELEPHONE AND TELEGRAPH EASEMENT EX I S T I N G W A T E R L I N E OF M A I N H O U S E EX I S T I N G 4 " SE W E R L A T E R A L W/H 22'-0" 12 ' - 0 " 15 ' - 0 " 22 ' - 0 " 50'-2" 18 ' - 4 " 4'-0" 27'-3" EXIST. STRUCTURE: 1,495 S.F. ADU: 1,000 S.F. 4:12 SLOPE 4: 1 2 S L O P E 4: 1 2 S L O P E 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4: 1 2 S L O P E 4: 1 2 S L O P E 5'-2" 12'-11" 20 0 A M P NE W A D U W A T E R L I N E C O N N E C T E D W I T H E X I S T I N G WA T E R L I N E O F M A I N H O U S E A T F R O N T Y A R D NEW S E W E R L I N E T O T I E T O 4 " L I N E A T FRON T Y A R D W / 1 / 4 " : 1 2 " S L O P E M I N . NE W G A S L I N E 1 1 4'' P I P E . 5'-10" 6' - 0 " 16 17 19 20 21 22 18 23 NOTE: PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFORMING ALL EXISTING UTILITY EASEMENTS AND/OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT 25 27 9 13 26 26 26 TR A S H A R E A TR A S H A R E A 12 21A 21B 19 3 5 11 13 1,071 SQ. FT. OPEN AREA 18 ' - 0 " FL O O D Z O N E A R E A I S O B T A I N E D B Y A P P L I C A N T BA S E O N F E M A W E B S I T E R E S E A R C H EXISTING LANDSCAPE. EXISTING CONCRETE DRIVEWAY.1 2 4 EXISTING CONCRETE PAVEMENT. 5 6 A.COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. B.ALL SETBACKS ARE MEASURED FROM PROPERTY LINE TO FACE OF BUILDING FINISH. C.FIELD VERIFY EXISTING CONDITIONS AND ELEVATIONS. IF ANY DISCREPANCIES ARE ENCOUNTERED, NOTIFY PROJECT ENGINEER TEAM PRIOR TO PROCEEDING WITH CONSTRUCTION. D.MAINTAIN MINIMUM OF 2% SLOPE AWAY FROM THE STRUCTURE. E.VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO COMMENCEMENT OF ANY WORK. F.VERIFY LOCATION OF WATER METERS, ELECTRIC METERS AND GAS METERS ARE IN ACCORDANCE WITH SERVICING UTILITY COMPANY REQUIREMENTS PRIOR TO FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICES REQUIREMENTS PRIOR TO CONCRETE PLACEMENT. EXISTING STREET SIDEWALK. EXISTING HOUSE. 7 8 9 EXISTING 6'H. BLOCK WALL TO REMAIN. 12 3 EXISTING CONCRETE STREET CURB. 10 CONVERT TO ELECTRICAL 200AMP SUB-PANEL OF MAIN HOUSE. 11 EXISTING GAS METER LOCATION. 13 UNDERGROUND CONNECTION FROM DUAL GANG METER TO SUB-PANEL FOR MAIN HOUSE. AREA NOT IN CONTRACT EXISTING 6'H. BLOCK WALL TO BE DEMOLISHED. EXISTING WATER METER LOCATION. NEW CONCRETE PAVING. NEW 6'H. WOOD GATE. 15 16 GAS METER FOR ADU. 17 NEW ADU. 14 18 NEW ADDITION FOR MAIN HOUSE. NEW ADDITION FOR MAIN HOUSE : 264 S.F. NEW DETACHED ADU : 1,000 S.F. EXISTING TREE TO BE DEMOLISHED. EXISTING LANDSCAPING TO BE DEMOLISHED. 19 20 21 22 NEW OVERHEAD POWER LINE FOR DUAL GANG METER. OPEN AREA: 1,945 S.F. NEW 400AMP ELECTRICAL DUAL METER PANEL: 200 SOCKET FOR MAIN HOUSE & 200 SOCKET FOR ADU. EXIST. STRUCT. 1,495 S.F. ADU 1,000 S.F. ADDITION 264 S.F. TOTAL 2,759 S.F. TOTAL LOT COVERAGE:2,759 S.F. (34 %) LOT AREA:8,076 S.F. ALLOWED LOT COVERAGE: 35% 23 NEW WATER HEATER CLOSET WITH LOUVER DOOR. PAINTED TO MATCH ADU EXTERIOR DOOR. 24 EXISTING STORAGE TO BE REMOVED. 25 OUTDOOR AIR CONDITIONER UNIT FOR ADU. 26 NEW 6'H. VINYL FENCE. 27 LEGALIZE OUTDOOR AIR CONDITIONER UNIT FOR MAIN HOUSE. SERVICE DISCONNECTING FOR ADU SHALL BE INSTALLED ADJACENT TO SUB-PANEL OUTSIDE OF BUILDING. [CEC 230.70] NEW 200AMP SUB-PANEL/LOAD CENTER FOR ADU. MINIMUM SIZE ADU SUB-PANEL BUS BAR RATING SHALL BE 225AMP [2022 CEnC 150.0 (S)]. PROVIDE MINIMUM 20 FEET UFER GROUND FOR NEW PANEL. 21A NEW 200AMP PANEL SUPPLYING ADU SHALL BE PROVIDED WITH TYPE 1 OR TYPE 2 SURGE-PROTECTIVE DEVICE (CEC 230.67). 21B AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b a o o . o 06/27/2024 2 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 SE-6:INSTALL TEMPORARY SAND BAGS TO PREVENT STORM WATER FROM ENTERING THE STREET DURING CONSTRUCTION. WM-8:IMPLEMENT CONCRETE WASHOUT AREA PER CASQA STANDARDS. WM-9:INSTALL SANITARY WASTE MANAGEMENT PER CASQA STANARDS. 1 WM-8 SE-6 RE F . ENTRY 200 AMP W/H ADDITION: 264 S.F. PR O P E R T Y L I N E 1 3 4 . 6 0 ' 4' A D U S I D E S E T B A C K PR O P E R T Y L I N E 1 3 4 . 6 0 ' 4' A D U S I D E S E T B A C K PROPERTY LINE 60' 4' ADU REAR SETBACK PROPERTY LINE 60' 5121 W Robert Dr. Santa Ana (E)POWER POLE (E) 6'H. BLOCK WALL (E ) 6 ' H . B L O C K W A L L (E ) 6 ' H . B L O C K W A L L 5' SCE EASEMENT 6' PACIFIC TELEPHONE AND TELEGRAPH EASEMENT W/H EXIST. STRUCTURE: 1,495 S.F. ADU: 1,000 S.F. RE F . ENTRY 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 S L O P E 4:12 SLOPE 4:12 SLOPE 4: 1 2 S L O P E 4: 1 2 S L O P E 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4: 1 2 S L O P E 4: 1 2 S L O P E 1: 1 2 S L O P E 4:12 SLOPE SE-6 5% 5% 5% 5%5%2%2% A - A - AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 A.COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. B.PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. C.ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER THE BUILDINGS. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. D.IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER. E.REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. F.REMOVE DESIGNATED COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. G.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE. EXISTING TO BE DEMOLISHED. KEY NOTES SYMBOLS GENERAL NOTES 1 2 AREA NOT IN CONTRACT EXISTING 2x WALL TO REMAIN 1 EXISTING / DEMOLITION FLOOR PLAN 1/4"=1'-0" REMOVE EXISTING WINDOWS AS SHOWN. INFILL WITH WALL TO MATCH ADJACENT CONSTRUCTION. MAKE WALL OPENING FOR RELOCATED WINDOW, REFER TO NEW LAYOUT FOR DIMENSIONING. 2 W/H 25 ' - 0 " EX I S T . 26 ' - 7 " EX I S T . 20 ' - 0 " EX I S T . 20'-0" EXIST. 42'-0" EXIST. 29'-11" EXIST. 21 ' - 7 " EX I S T . 1 2 3 EXISTING WATER HEATER LOCATION TO REMAIN. 4 EXISTING WASHER / DRYER LOCATION TO REMAIN. 3 4 3' - 6 1 / 2 " 3' - 6 1 / 2 " 5 PATIO COVER TO BE DEMOLISHED. EXISTING CONCRETE SLAB TO BE CUT BACK. 5 6 6 OUTDOOR CENTRAL AIR TO BE LEGALIZED. 7 REPLACE WINDOW / DOOR AT EXISTING LOCATION TO MATCH COLOR & STYLE WITH OTHER LOCATION. 77 1 2'-6" AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 c o m s t o c k r o a d g a r d e n g r o v e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : d e s i g n 2 b u i l d @ y a h o o . c o m 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.EMERGENCY EXITS ARE REQUIRED IN ALL SLEEPING AREAS AND MAY BE PROVIDED BY A DOOR OR WINDOW OPENING DIRECTLY TO THE OUTSIDE. EMERGENCY EGRESS WINDOWS IN ALL SLEEPING ROOMS MUST COMPLY WITH THE FOLLOWING: A.A 20" MINIMUM OPENING WIDTH B.A 24" MINIMUM OPENING HEIGHT C.CLEAR OPENING NO HIGHER THAN 44" ABOVE FINISHED FLOOR [CH 3 CRC] 3.LABELED SAFETY GLASS [CH 3 CRC] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 72" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. . E.ALL GLAZING WHERE THE NEAREST EXPOSED EDGE OF THE GLASS IS WITHIN 24'' OF EITHER VERTICAL EDGE OF A DOOR IN THE PLANE OF THE DOOR IN CLOSED POSITION. F.GLAZING ON A WALL LESS THAN 180 DEGREES FROM THE PLANE OF DOOR IN A CLOSED POSITION AND WITHIN 24'' OFF THE HINGE SIDE OF AN IN-SWINGING DOOR. 4.ALL EXTERIOR DIMENSIONS ARE FROM FACE OF SHEATHING, BLOCK OR STRUCTURE (F.O.S.) TYP. UNLESS NOTED OTHERWISE. VERIFY DIMENSION CHANGES WITH ENGINEER PRIOR TO COMMENCEMENT OF WORK. 5.ALL INTERIOR DIMENSIONS ARE FROM FACE OF GYPSUM BOARD. 6.CONTRACTOR SHALL NOT SCALE PLANS. ALL DIMENSIONS SHALL BE VERIFIED IN FIELD. 7.ALL PLUMBING FIXTURES SHALL BE COMPLYING WITH THE MAXIMUM FLOW RATES AS NOTED IN THE RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS. 8.PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(C), ALL NON-COMPLIANT PLUMBING FIXTURES WITHIN THIS RESIDENCE SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. 1 LAVATORY WITH BASE CABINET. FAUCET FLOW SHALL NOT EXCEED 1.2 GALLONS AT 60 PSI, MINIMUM 0.8 GALLONS PER MINUTE AT 20 PSI. 2 WATER CLOSET - 1.28 GALLONS PER FLUSH MAX. 3 SHOWER BASE: HOT-MAP PAN. PROVIDE TILE W/ CEMENT BACKING MIN. 72" HIGHT ABOVE SHOWER DRAIN, NET AREA 7.1 S.F. MIN., 30"DIA. CLEAR SPACE MIN. (CPC 411.7). 4 SHOWER HEAD FLOW IS 1.8 GPM MAX. SHOWER FITTING TO HAVE ACCESS PANEL OR ONE PIECE WELD TRAP PER LOCAL CODE 5 TEMPERED GLASS SHOWER ENCLOSURE, FRAMED GLASS WITH 22" OPENING MIN. UNOBSTRUCTED FOR EGRESS. REFER TO SHEET A12.00 FOR WALL TYPE DETAILS, U.N.O. EXISTING 2x WALL TO REMAIN NEW 2x WALL AREA NOT IN CONTRACT DOOR & WINDOW SCHEDULE 3'-5" 1 A9.00 W/H 12 ' - 0 " 22'-0" 5'-0" 8' - 0 " 3' - 3 " 6' - 0 " 5' - 6 1 / 2 " 5' - 6 1 / 2 " 12 ' - 0 " 2' - 8 " 2' - 6 " 2' - 1 0 " D0 1 . 0 1 D01.02 D01.03 W01.01 W01.02 1 A08.00 2 A08.00 3 A08.00 4 A08.00 1 2 3 4 5 W 0 1 . 0 3 EW01.01 EW01.02 W01.04* EW01.03 W 0 1 . 0 4 E W 0 1 . 0 5 EW01.06 6 EXISTING WATER HEATER LOCATION TO REMAIN. 7 EXISTING WASHER / DRYER LOCATION TO REMAIN. 6 7 8 LEGALIZE WINDOW REPLACEMENT WITH NEW AT EXISTING LOCATION. 8 D01.04 9 NEW COVERED PATIO OVER EXISTING CONCRETE SLAB. 9 20'-0" 10 LEGALIZE INSTALLATION OF CENTRAL AIR FOR MAIN HOUSE. 10 E W 0 1 . 0 7 8 5'-3"2'-6" 3'-1" Ø2'-6" 2 A9.00 8 EQ.EQ. AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b a o o . o 06/27/2024 2 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 2 A9.01 RE F . ENTRY 200 AMP 1 2 5 4 3 1 2 5 4 3 6 7 8 9 10 11 11 12 TYP. THRU-OUT D0 1 . 0 1 D01.0 2 D0 1 . 0 3 D0 1 . 0 4 D0 1 . 0 5 D0 1 . 0 6 D01.07 D0 1 . 0 8 D01.0 9 W01.01 W01.02 W 0 1 . 0 4 W01.05 W01.09 1 A08.01 2 A08.01 3 A08.01 4 A08.01 ADU DOOR & WINDOW SCHEDULE W01.06 W 0 1 . 0 3 14 15A 15B 15E 16 13A 13B 17 15C 1 A9.01 22 ' - 0 " 4' - 5 1 / 2 " 4' - 5 1 / 2 " 4' - 5 1 / 2 " 4' - 5 1 / 2 " 3' - 4 " 49'-0" 12'-3"2'-0"7'-10"12'-11" 12'-3" 2'-4" 3' - 1 1 / 2 " 10 ' - 5 1 / 2 " 10 ' - 4 1 / 2 " 7' - 4 " 5' - 4 1 / 2 " 22 ' - 0 " 5' - 9 1 / 2 " 4'-6"11'-3" 10'-2" 2'-4"2'-8" 5'-0"1'-0" 2'-10" 1'-0" 6" 5' - 0 " 2'-4"2'-6"3'-0" 3' - 1 1 / 2 " 3' - 1 1 / 2 " 3' - 1 1 / 2 " 3' - 0 " 5' - 0 " 6'-1" W 0 1 . 0 7 W 0 1 . 0 8 D01 . 0 9 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.EMERGENCY EXITS ARE REQUIRED IN ALL SLEEPING AREAS AND MAY BE PROVIDED BY A DOOR OR WINDOW OPENING DIRECTLY TO THE OUTSIDE. EMERGENCY EGRESS WINDOWS IN ALL SLEEPING ROOMS MUST COMPLY WITH THE FOLLOWING: A.A 20" MINIMUM OPENING WIDTH B.A 24" MINIMUM OPENING HEIGHT C.CLEAR OPENING NO HIGHER THAN 44" ABOVE FINISHED FLOOR [CH 3 CRC] 3.LABELED SAFETY GLASS [CH 3 CRC] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 72" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. . E.ALL GLAZING WHERE THE NEAREST EXPOSED EDGE OF THE GLASS IS WITHIN 24'' OF EITHER VERTICAL EDGE OF A DOOR IN THE PLANE OF THE DOOR IN CLOSED POSITION. F.GLAZING ON A WALL LESS THAN 180 DEGREES FROM THE PLANE OF DOOR IN A CLOSED POSITION AND WITHIN 24'' OFF THE HINGE SIDE OF AN IN-SWINGING DOOR. 4.ALL EXTERIOR DIMENSIONS ARE FROM FACE OF SHEATHING, BLOCK OR STRUCTURE (F.O.S.) TYP. UNLESS NOTED OTHERWISE. VERIFY DIMENSION CHANGES WITH ENGINEER PRIOR TO COMMENCEMENT OF WORK. 5.ALL INTERIOR DIMENSIONS ARE FROM FACE OF GYPSUM BOARD. 6.CONTRACTOR SHALL NOT SCALE PLANS. ALL DIMENSIONS SHALL BE VERIFIED IN FIELD. 7.ALL PLUMBING FIXTURES SHALL BE COMPLYING WITH THE MAXIMUM FLOW RATES AS NOTED IN THE RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS. 1 LAVATORY WITH BASE CABINET. FAUCET FLOW SHALL NOT EXCEED 1.2 GALLONS AT 60 PSI, MINIMUM 0.8 GALLONS PER MINUTE AT 20 PSI. 2 WATER CLOSET - 1.28 GALLONS PER FLUSH MAX. 3 SHOWER BASE: HOT-MAP PAN. PROVIDE TILE W/ CEMENT BACKING MIN. 72" HIGHT ABOVE SHOWER DRAIN, NET AREA 7.1 S.F. MIN., 30"DIA. CLEAR SPACE MIN. (CPC 411.7). 4 SHOWER HEAD FLOW IS 1.8 GPM MAX. SHOWER FITTING TO HAVE ACCESS PANEL OR ONE PIECE WELD TRAP PER LOCAL CODE 5 TEMPERED GLASS SHOWER ENCLOSURE, FRAMED GLASS WITH 22" OPENING MIN. UNOBSTRUCTED FOR EGRESS. 6 7 KITCHEN BASE CABINETRY8 10 KITCHEN UPPER CABINET REFER TO SHEET A12.00 FOR WALL TYPE DETAILS, U.N.O. PROVIDE NEW CLOSET & HANGING ROD11 PROVIDE GAS LINE FOR COOKING STOVE. RANGE HOOD ABOVE, VENT TO EXTERIOR & SHALL COMPLY WITH ASHRAE 62.2(C). 9 KITCHEN SINK & FAUCET IS 1.8 GPM MAX. AT 60 PSI NEW WALL 12 CEILING HEIGHT SHALL BE 9'-0". REFER TO 2/A03.01. PROVIDE CONCRETE LANDING AS SHOWN ON PLAN. LANDING SHALL BE MIN. 3' ON EGRESS DIRECTION. 16 REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. REINFORCEMENT SHALL NOT BE LESS THAN 2" x 8" NOMINAL LUMBER (1-1/2” X 7-1/4” ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6” ABOVE THE BATHTUB RIM. 15A 15B 14 PROVIDE DOORBELL BUTTON/CONTROL. INSTALLATION SHALL NOT EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. 15 INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION & MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CH. 4, DIVISION 4.4. REINFORCEMENT FOR GRAB BARS SHALL COMPLY AS FOLLOWING [R327.1.1]: 15C 15D 15E 13A PROVIDE WATER HEATER CLOSET WITH EXT. CEMENT PLASTER WALLS & 30"x80" LOUVER DOOR. PAINTED TO MATCH ADU EXTERIOR DOOR. HEAT PUMP WATER HEATER WITH 18''H. SHELF & METAL PAN. HP WATER HEATER SHALL BE STRAPPED TO STRUCTURE WITH 1 1 2" x 16GA STRAPS AT TOP & BOTTOM WITH 3 8"DIA. x 3" LONG LAG BOLT. 13B 17 SEPARATE ELECTRICAL PANEL FOR ADU. AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1 ELECTRIC PLAN 1/4"=1'-0" 1.2 GFCI WP +48'' GFCI AFCI AFCI CTV AFCI AFCI W/H AFCI 1.1 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.ALL ELECTRICAL OUTLET TO BE MOUNTED @ 15" A.F.F. 3.PROVIDE TAMPER-RESISTANT FOR ALL 15 & 20 AMP RECEPTACLES IN NEW CONSTRUCTION AREA PER CEC 406.12. 2.1 FLUSH WALL MOUNTED PHONE RECEPTACLE CTV FLUSH WALL MOUNTED CABLE TV RECEPTACLE FLUSH WALL MOUNTED DUPLEX RECEPTACLE, TAMPER RESISTANT FLUSH WALL MOUNTED DEDICATED DUPLEX RECEPTACLE FLUSH WALL MOUNTED HALF-SWITCHED DUPLEX RECEPTACLE FLUSH WALL MOUNTED QUADRAPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPTERGFCI WATERPROOF RECEPTACLEWP EXISTING 200AMP ELECTRICAL PANEL FOR MAIN HOUSE.2.2 OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANT PER SECTION 406.9(B) (1). 1.1 PROVIDE A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM, PER CEC 210-52(C) (1). 1.2 CEILING MOUNTED SMOKE DETECTOR IN EACH BEDROOM & KITCHEN. INSTALL +30" FROM AIR INTAKE SMOKE DETECTOR SYSTEM SHALL DIRECT WIRED, INTERCONNECTED, SHALL BE EQUIPPED WITH A BATTERY BACKUP AND SHALL EMIT A SIGNAL WHEN THE BATTERY IS LOW. A.AMINIMUM OF 20 FT. FROM PERMENANT COOKING EQUIPMENT (OR 10 FT WITH PHOTO ELECTRIC TYPE.) B.A MINIMUM OF 3 FT. FROM BATHROOM. CEILING MOUNTED CARBON MONOXIDE ALARM ALARM TO BE INTERCONNECTED, SHALL BE EQUIPPED WITH A BATTERY BACKUP RECESSED LED DOWN LIGHT FIXTURE WALL MOUNTED EXTERIOR LED LIGHT FIXTURE, HIGH EFFICACY AND CONTROL BY MOTION SENSOR AND PHOTO-SENSOR COMBINATIONS. D / VS LIGHT SWITCH. ALL SWITCHES TO HAVE DIMMER CONTROL, EXCEPT, UTILITY & LAUNDRY RM, GARAGE WALL MOUNTED BATHROOM LED LIGHT FIXTURE EF SD CM D INDICATE DIMMER VS INDICATE OCCUPANCY SENSOR #FINISHED CEILING HEIGHT CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT COMBINATION. EXHAUST FAN TO EXTERIOR WITH RATE = 50 CFM. EXHAUST FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE CAPABLE ADJUSTMENT BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. EXISTING SMOKE ALARMS & EXISTING CARBON MONOXIDE ALARM IN EXISTING HALLWAY. 2.3 EXHAUST FAN MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. AND SHOULD BE HUMIDISTAT FAN. PROVIDE LIGHTING WITH CONTROLLED BY VACANCY SENSOR IN BATHROOM, W.I. CLOSET. 4.ALL INSTALLED LUMINARIES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. 5.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. 6.IN BATHROOMS, GARAGE, LAUNDRY ROOM, UTILITY ROOM, AT LEAST ONE LUMINARIES IN EACH OF THESE SPACES MUST BE CONTROLLED BY VACANCY SENSOR. 7.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING MUST MEET THE REQUIREMENT IN ITEM 150.0(k)3Ai (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(k)3Aii (PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(k)3Aiii (PHOTO CONTROL AND AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS). 8.SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: [150.0(K) / 160.5(A)] A.KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN KITCHENS SHALL BE HIGH EFFICACY. B.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR. C.HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A VACANCY/ OCCUPANCY SENSOR OR DIMMER. D.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION (WITH OVERRIDE). SEE 150(K)3 FOR REQUIREMENTS. 2.4 2.6 PROVIDE NEW ACCESS DOOR FOR ADDITION ATTIC AREA. OPENING SHALL BE 30" x 30" WITH 30" MIN. HEADROOM. EXISTING ACCESS DOOR FOR EXISTING ATTIC AREA. OPENING IS 30" x 30" WITH 30" MIN. HEADROOM. ACCESS DOOR IS WITHIN 20 FEET OF FURNACE UNIT AND HAVE A CONTINUOUS SOLID PATHWAY 24" MIN. WIDE WITH A SWITCH CONTROLLED LIGHT. 2.5 NEW SMOKE ALARMS WITHIN 20 FEET OF COOK TOP SHALL BE IONIZED OR PHOTOELECTRIC TYPE. SD EF CM SD vs W/H D 2' - 0 " 7' - 1 " 2' - 6 " 3'-0"6'-5" SD SDSD CM SD (E)(E) (E)(E) (E) 2.1 2 CEILING / LIGHTING PLAN 1/4"=1'-0" 2.22.3 2.5 2.4 2.1 2.1 2.1 2.6 AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o k r o a a r e n r o v e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s i n 2 b i @ a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1.4 1.5 1 ELECTRIC PLAN 1/4"=1'-0" ·ALL RECEPTACLES AT KITCHEN COUNTER TOP SHALL BE AFCI & GFCI. 1.2 1.2 1.3 1.6 1.7 1.8 1.9 1.10 GFCI CTV AFCI AFCI CR +65" +48" GFCI GFCI AFCI WD R GFCI WP +32" GFCI WH EP +48" GFCI RE F . ENTRY 200 AMP H +48" GFCI +48" GFCI GFCI WP CTV AFCI +66" GFCIGFCI 240V AFCI AFCI AFCI AFCI AFCI CTV AFCI AFCI GFCI.240V AFCI +48" GFCI +32" GFCI+48" GFCI AFCI 1.1 1.5A 1.1 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.ALL ELECTRICAL OUTLET TO BE MOUNTED @ 15" A.F.F. 3.ALL APPLIANCES TO BE "ENERGY STAR". 4.PROVIDE TAMPER-RESISTANT FOR ALL 15 & 20 AMP RECEPTACLES IN NEW CONSTRUCTION AREA PER CEC 406.12. 5.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOOR WITH RATE = 280 CFM. 2.1 FLUSH WALL MOUNTED PHONE RECEPTACLE CTV FLUSH WALL MOUNTED CABLE TV RECEPTACLE FLUSH WALL MOUNTED DUPLEX RECEPTACLE, TAMPER RESISTANT FLUSH WALL MOUNTED DEDICATED DUPLEX RECEPTACLE FLUSH WALL MOUNTED HALF-SWITCHED DUPLEX RECEPTACLE FLUSH WALL MOUNTED QUADRAPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPTERGFCI WATERPROOF RECEPTACLEWP R H CR RANGE HOOD WITH A MIN. EXHAUST RATE OF 100 CFM - VENTED TO OUTSIDE ELECTRICAL COOKING RANGE REFRIGERATOR - PROVIDE WATER LINE FAU EP2 200AMP ELECTRICAL PANEL FOR ADU - MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION W/H NEW200AMP ELECTRICAL SUB-PANEL FOR ADU. PROVIDE MIN 20 FEET UFER GROUND FOR NEW PANEL. FAU LOCATED IN ATTIC WITH VERTICAL DUCT VENT TO EXTERIOR. PROVIDE POWER CONNECTION . PROVIDE MINIMUM 36"x36" CLEAR WORKING SPACE PLATFORM IN FRONT OF UNIT. 2.2 OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANT PER SECTION 406.9(B) (1). 1.1 PROVIDE A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM, PER CEC 210-52(C) (1). 1.2 PROVIDE A MINIMUM OF (2) 20-AMP SMALL APPLIANCE CIRCUITS FOR KITCHEN COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOAD SHALL BE BALANCED, PER CEC 210-52(B) (2). 1.3 CEILING MOUNTED SMOKE DETECTOR IN EACH BEDROOM & KITCHEN. INSTALL +30" FROM AIR INTAKE SMOKE DETECTOR SYSTEM SHALL DIRECT WIRED, INTERCONNECTED, SHALL BE EQUIPPED WITH A BATTERY BACKUP AND SHALL EMIT A SIGNAL WHEN THE BATTERY IS LOW. A.AMINIMUM OF 20 FT. FROM PERMENANT COOKING EQUIPMENT (OR 10 FT WITH PHOTO ELECTRIC TYPE.) B.A MINIMUM OF 3 FT. FROM BATHROOM. CEILING MOUNTED CARBON MONOXIDE ALARM ALARM TO BE INTERCONNECTED, SHALL BE EQUIPPED WITH A BATTERY BACKUP RECESSED LED DOWN LIGHT FIXTURE WALL MOUNTED EXTERIOR LED LIGHT FIXTURE, HIGH EFFICACY AND CONTROL BY MOTION SENSOR AND PHOTO-SENSOR COMBINATIONS. D / VS LIGHT SWITCH. ALL SWITCHES TO HAVE DIMMER CONTROL, EXCEPT, UTILITY & LAUNDRY RM, GARAGE WALL MOUNTED BATHROOM LED LIGHT FIXTURE EF SD CM D INDICATE DIMMER VS INDICATE OCCUPANCY SENSOR WHOLE-BUILDING MECHANICAL VENTILATION SYSTEM WITH CFM PER T24 - PANASONIC OR EQUAL. SYSTEM MUST DELIVER CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN OR EQUAL TO THE SPECIFIED AND FAN SOUND RATING MUST NOT EXCEED 1.0 FOR DWELLING OCCUPANT DENSITIES KNOW TO BE GREATER THAN (NUMBER OF BEDROOM + 1), THE RATE SHALL BE INCREASED BY 7.5 FOR EACH ADDITIONAL PERSON. V #FINISHED CEILING HEIGHT CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT COMBINATION. EXHAUST FAN TO EXTERIOR WITH RATE = 50 CFM. EXHAUST FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE CAPABLE ADJUSTMENT BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. PROVIDE GARBAGE DISPOSAL CONNECTED TO HALF -SWITCHED OUTLET UNDER KITCHEN SINK WITH ADJACENT CONTROL SWITCH ABOVE CONTERTOP. 1.4 SMOKE ALARMS WITHIN 20 FEET OF COOK TOP SHALL BE IONIZED OR PHOTOELECTRIC TYPE. 2.3 WHOLE-BUILDING VENTILATION SYSTEM LOCATION. ITS AIRFLOW RATE SHALL BE 59 CFM MIN. 2.4 PROVIDE A MINIMUM 4" DIA. MOISTER EXHAUST DUCT (WITH SMOOTH INTERIOR FINISH) TO OUTSIDE, EQUIPPED WITH BACK-DRAFT DAMPER. DUCT LENGTH IS LIMITED OR REQUIRED BY THE MANUFACTUER'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE BUILDING OFFICIAL. 2.5 2.6 LIGHT FIXTURE WITHIN3' HORIZONTALLY AND 8' VERTICALLY OF SHOWER STALL THRESHOLD SHALL BE LISTED FOR DAMP LOCATION, OR LISTED FOR WET LOCATION. CEC 150.0(k) AND CEC 410.10. PROVIDE KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOOR WITH RATE = 280 CFM . EXHAUST FAN MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. AND SHOULD BE HUMIDISTAT FAN. PROVIDE LIGHTING WITH CONTROLLED BY VACANCY SENSOR IN BATHROOM. 1.5 1.6 2.7 2.8 2.9 6. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: A. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS; OR B. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS IN SEC. 150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN 1 INCH. THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS.” 7.A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. 8.THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. 9.SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/ TRANSFER SWITCH WITHIN 3 FT. OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. 10.ALL INSTALLED LUMINARIES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. 11.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. 12.IN BATHROOMS, GARAGE, LAUNDRY ROOM, UTILITY ROOM, AT LEAST ONE LUMINARIES IN EACH OF THESE SPACES MUST BE CONTROLLED BY VACANCY SENSOR. 13.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING MUST MEET THE REQUIREMENT IN ITEM 150.0(k)3Ai (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(k)3Aii (PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(k)3Aiii (PHOTO CONTROL AND AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS). 14.SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: [150.0(K) / 160.5(A)] A.KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN KITCHENS SHALL BE HIGH EFFICACY. B.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR. C.HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY A VACANCY/ OCCUPANCY SENSOR OR DIMMER. D.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION (WITH OVERRIDE). SEE 150(K)3 FOR REQUIREMENTS. FOR HEAT PUMP WATER HEATER: PROVIDE A DEDICATED 125V, 20A ( 10 AWG COPPER BRANCH CIRCUIT) ELECTRIC RECEPTACLE THAT WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "240V USE". BOTH ENDS OF CONDUCTOR SHALL BE LABELED WITH WORD "WATER HEATER" AND BE ELECTRICALLY ISOLATED. HEAT PUMP WATER HEATER WITH 18''H. SHELF & METAL PAN. HP WATER HEATER SHALL BE STRAPPED TO STRUCTURE WITH 1 12" x 16GA STRAPS AT TOP & BOTTOM WITH 3 8"DIA. x 3" LONG LAG BOLT - PROVIDE DRAIN LINE WATER SHUT-OFF VALVE, POWER, GAS LINE. A CONDENSATE DRAIN THAT IS NO MORE THAN 2" HIGHER THAN THE BASE OF INSTALLED WH, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. HP WATER HEATER SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S REQUIREMENTS. HP HP HEAT PUMP FURNACE LOCATED IN ATTIC WITH VERTICAL DUCT VENT TO EXTERIOR. PROVIDE POWER CONNECTION . PROVIDE MINIMUM 36"x36" CLEAR WORKING SPACE PLATFORM IN FRONT OF UNIT. PROVIDE ACCESS DOOR . OPENING SHALL BE 30" x 30" WITH 30" MIN. HEADROOM. ACCESS DOOR MUST BE WITHIN 20 FEET OF FURNACE UNIT AND SHOULD HAVE A CONTINUOUS SOLID PATHWAY 24" MIN. WIDE. PROVIDE A SWITCH CONTROLLED LIGHT. [CMC. 304.4.1] FOR ELECTRIC CLOTHES DRYER READY: A DEDICATED 240 V BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE WITH NO OBSTRUCTION. THE THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30AMPS MIN. THE BLANK COVER SHALL BE IDENTIFIED AS "240V READY". THERE SHALL BE A RESERVED DOUBLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "240V DRYER". FOR HEAT PUMP HEATER: IN ATTIC SPACE, PROVIDE A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS.THERE SHALL BE A RESERVED SINGLE POLE BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "240V FURNACE". FOR ELECTRIC COOKTOP READY: A DEDICATED 240 V BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE WITH NO OBSTRUCTION. THE THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30AMPS MIN. THE BLANK COVER SHALL BE INDENTIFIED AS "240V READY". THERE SHALL BE A RESERVED DOUBLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "240V COOKTOP". 1.7 1.8 1.9 1.10 SERVICE DISCONNECTING FOR ADU SHALL BE INSTALLEDADJACENT TO SUB-PANEL OUTSIDE OF BUILDING. [CEC 230.70] NEW 200AMP PANEL FOR ADU. MINIMUM SIZE ADU SUB-PANEL BUS BAR RATING SHALL BE 225AMP [2022 CEnC 150.0 (S)]. PROVIDE MINIMUM 20 FEET UFER GROUND FOR NEW PANEL. 1.5A NEW 200AMP PANEL SUPPLYING ADU SHALL BE PROVIDED WITH TYPE 1 OR TYPE 2 SURGE-PROTECTIVE DEVICE (CEC 230.67). 2.9 2 CEILING / LIGHTING PLAN 1/4"=1'-0" 2.7 2.1 2.2 2.5 2.3 EF 280 CFM D D VS SD SD CMV SD 50 CFM 3'-0" 6' - 0 " 2' - 6 " 6'-0" RE F . ENTRY 200 AMP 9'-0" 2' - 6 " 6'-0" D EF VS 50 CFM 3'-0" D 2.4 2.8 2.7 2.8 2.5 AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o k r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s i n 2 b i @ a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 KEY NOTES SYMBOLS GENERAL NOTES A.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. B.NEW ROOFING, "CLASS A" FIRE RETARDANT INSTALLED OVER MIN. (2) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. C.ROOF INSULATION PER TITLE 24 CALCULATION. INSULATION SHALL CONFORM TO FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF 2019 CBC. D.VENT OPENINGS SHALL HAVE CORROSION RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/16" MIN. AND 1/8" MAX. OPENINGS. E.NOT MORE THAN 50% OF THE VENTS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE. F.PROVIDE MIN. 24 GAUGE GALVANIZED SHEETING FOR ALL EXTERIOR FLASHING& WEATHER STRIPPING APPLICATIONS. ROOF SLOPE PER PLAN ATTIC VENT CALC. 1 EDGE OF ROOF. EXTERIOR WALL BELOW.1 2 3 EAVE VENT 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG CLASS A ASPHALT SHINGLE ROOFING ICC ESR-1389 INSTALLATION: OVER (1) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. NEW ROOF ADDITION OF MAIN HOUSE: TOTAL ATTIC AREA REQUIRED VENTILATION: 264 S.F. / 150 = 1.76 S.F. 1.76 S.F. x 144 = 253.44 S.I. PROVIDE EAVE VENT: (6) 4x12 = 288 S.I. TOTAL = 288 S.I. CLASS A ASPHALT SHINGLE ROOFING CERTAINTEED ROOFING OR EQUAL GRAND MANOR, BROWNSTONE COLOR (CLOSE TO ORIGINAL ROOFING COLOR) 4: 1 2 S L O P E 4:12 SLOPE 4:12 SLOPE 4: 1 2 S L O P E 4: 1 2 S L O P E 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4:12 SLOPE 4: 1 2 S L O P E 4: 1 2 S L O P E 1: 1 2 S L O P E 4:12 SLOPE 12 ' - 0 " NE W R O O F A D D I T I O N 24'-0" NEW ROOF ADDITION 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG 1' - 0 " RO O F OV E R H A N G 1'-0" ROOF OVERHANG 123 4 4 NEW PATIO ROOF WITH BUILT-UP ROOFING MATERIAL. ICC ESR - 1654 MFM GAF RUBEROID® EnergyCap™ 30 Granule FR Membrane AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o m s t o r o a g a r e n g r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s g n 2 b u l y a o o . o m 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 RE F . ENTRY 200 AMP 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 PAINTED GALVANIZED GUTTER. 1' - 2 " RO O F OV E R H A N G 1'-2" ROOF OVERHANG 128 A12.00 5 6 KEY NOTES SYMBOLS GENERAL NOTES A.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. B.NEW ROOFING, "CLASS A" FIRE RETARDANT INSTALLED OVER MIN. (2) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. C.ROOF INSULATION PER TITLE 24 CALCULATION. INSULATION SHALL CONFORM TO FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF 2019 CBC. D.VENT OPENINGS SHALL HAVE CORROSION RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/16" MIN. AND 1/8" MAX. OPENINGS. E.NOT MORE THAN 50% OF THE VENTS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE. F.PROVIDE MIN. 24 GAUGE GALVANIZED SHEETING FOR ALL EXTERIOR FLASHING& WEATHER STRIPPING APPLICATIONS. ROOF SLOPE PER PLAN ATTIC VENT CALC. 1 12 EDGE OF ROOF. EXTERIOR WALL BELOW.1 2 3 DOMER VENT PER VENT CALCULATION BELOW.4 1' - 2 " RO O F OV E R H A N G 6" ROOF OVERHANG CLASS A ASPHALT SHINGLE ROOFING ICC ESR-1389 INSTALLATION: OVER (1) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. 1' - 2 " RO O F OV E R H A N G 1'-2" ROOF OVERHANG 1' - 2 " RO O F OV E R H A N G 1'-2" ROOF OVERHANG 1' - 2 " RO O F OV E R H A N G 1'-2" ROOF OVERHANG NEW ROOF OF ADU: TOTAL ATTIC AREA REQUIRED VENTILATION: 1,000 SF/150 = 6.6 SF 6.6 SF x 144 = 960 S.I. PROVIDE DORMER VENT: (2)12"x24" (226S.I. EA.)= 452 S.I. EAVE VENT: (16) 12" x 4" = 768 S.I. TOTAL = 1,220 S.I. CLASS A ASPHALT SHINGLE ROOFING CERTAINTEED ROOFING OR EQUAL GRAND MANOR, BROWNSTONE COLOR (MATCH MAIN HOUSE'S NEW ROOFING COLOR) 3 NORTH PROPERTY LINE 6 LOCATION FOR -kW PHOTO VOLTAIC SYSTEM. EAVE VENT PER VENT CALCULATION BELOW. 4 TYP. 5 TYP. 18 ' - 4 " 4 A12.00 4 A12.00 8 A12.00 4 TYP. 5 TYP. AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o k r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b a o o . o 06/27/2024 2 2 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.EMERGENCY EXITS ARE REQUIRED IN ALL SLEEPING AREAS AND MAY BE PROVIDED BY A DOOR OR WINDOW OPENING DIRECTLY TO THE OUTSIDE. EMERGENCY EGRESS WINDOWS IN ALL SLEEPING ROOMS MUST COMPLY WITH THE FOLLOWING: A.A 20" MINIMUM OPENING WIDTH B.A 24" MINIMUM OPENING HEIGHT C.CLEAR OPENING NO HIGHER THAN 44" ABOVE FINISHED FLOOR [CH 3 CRC]. 3.LABELED SAFETY GLASS [CH 3 CRC] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 72" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 4.ALL BUILDING MATERIALS SHALL BE APPROVED FHSZ EXTERIOR, NBMC & CBC 708A. 5.PROVIDE MIN. 24 GAUGE GALVANIZED SHEETING FOR ALL EXTERIOR FLASHING& WEATHER STRIPPING APPLICATIONS. GENERAL NOTES EXTERIOR CEMENT PLASTER TEXTURE & FINISH TO MATCH EXISTING. INSTALLATION: 3-COAT (7/8" THICK) CEMENT PLASTER O/ SELF FURRING PAPER BACKED STUCCO NETTING O/ 1 LAYER GRADE 'D' PAPER (TOTAL 2 LAYERS GRADE 'D' PAPER) EXTERIOR MATERIAL SPECIFICATIONS ROOFING KEY NOTES 1 1 NEW ROOF OF NEW STRUCTURE MATCHING EXISTING 2 EXISTING EXTERIOR CEMENT PLASTER OF EXISTING STRUCTURE 3 EXISTING WINDOW OF EXISTING STRUCTURE 4 5 6 EXTERIOR CEMENT PLASTER TO MATCH EXISTING MAIN HOUSE TEXTURE & COLOR. WINDOW PER PLAN TO MATCH EXISTING MAIN HOUSE WINDOW STYLE AND FINISH. NEW FACIAL OF NEW STRUCTURE MATCHING EXISTING CLASS A ASPHALT SHINGLE ROOFING ICC ESR-1389 INSTALLATION: OVER (1) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. CERTAINTEED ROOFING OR EQUAL COLOR & STYLE TO MATCH EXISTING. 4 12 4 12 8' - 1 " TO P P L A T E 4 12 4 12 4 12 4 12 TOP OF SLAB 0.00 TOP OF TOP PLATE 8'-1" (MATCH EXISTING) 6' - 8 " 12 ' - 4 " TOP OF SLAB 0.00 TOP OF TOP PLATE 8'-1" (MATCH EXISTING) 12 ' - 4 " TOP OF SLAB 0.00 TOP OF TOP PLATE 8'-1" (MATCH EXISTING) 6' - 8 " 2' - 9 " 12 ' - 4 " 1A 2 2A 3 3A 22'-0" NEW ADDITION AREA 12'-0" NEW ADDITION AREA 12'-0" NEW ADDITION AREA 1 1 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP.2 TYP. 3 TYP. 3 TYP. 3 TYP. 6 TYP. 2 2 14 5 5 5 6 6 4 12 4 12 4 12 2 TYP. 3 TYP. 4 12 7 PROVIDE NEW TRIM AROUND NEW WINDOWS & DOORS AT MAIN HOUSE TO MATCH EXISTING. 7 7 7 3 TYP.7 7 77 8 DEMOLISH PATIO ROOF & POST. 8 8 7 6 AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 c o m s t o c k r o a d g a r d e n g r o v e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : d e s i g n 2 b u i l d @ y a h o o . c o m 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.EMERGENCY EXITS ARE REQUIRED IN ALL SLEEPING AREAS AND MAY BE PROVIDED BY A DOOR OR WINDOW OPENING DIRECTLY TO THE OUTSIDE. EMERGENCY EGRESS WINDOWS IN ALL SLEEPING ROOMS MUST COMPLY WITH THE FOLLOWING: A.A 20" MINIMUM OPENING WIDTH B.A 24" MINIMUM OPENING HEIGHT C.CLEAR OPENING NO HIGHER THAN 44" ABOVE FINISHED FLOOR [CH 3 CRC]. 3.LABELED SAFETY GLASS [CH 3 CRC] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 60" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 4.ALL BUILDING MATERIALS SHALL BE APPROVED FHSZ EXTERIOR, NBMC & CBC 708A. 5.PROVIDE MIN. 24 GAUGE GALVANIZED SHEETING FOR ALL EXTERIOR FLASHING& WEATHER STRIPPING APPLICATIONS. GENERAL NOTES EXTERIOR CEMENT PLASTER TEXTURE & FINISH PER OWNER INSTALLATION: 3-COAT (7/8" THICK) CEMENT PLASTER O/ SELF FURRING PAPER BACKED STUCCO NETTING O/ 1 LAYER GRADE 'D' PAPER (TOTAL 2 LAYERS GRADE 'D' PAPER) EXTERIOR MATERIAL SPECIFICATIONS KEY NOTES 1 NEW ROOF OF NEW STRUCTURE MATCHING EXISTING MAIN HOUSE. 2 EXTERIOR CEMENT PLASTER OF EXTERIOR STRUCTURE MATCHING EXISTING MAIN HOUSE 3 4 5 6 7 WINDOW PER PLAN TO MATCH EXISTING MAIN HOUSE WINDOW STYLE AND FINISH. WINDOW SHALL HAS 4" PLASTER TRIM TO MATCH MAIN HOUSE'S. DOOR PER PLAN TO MATCH EXISTING MAIN HOUSE ENTRY DOOR STYLE AND COLOR. DOOR SHALL HAS 4" TRIM STUCCO TRIM TO MATCH MAIN HOUSE'S. 8 NEW CONCRETE LANDING NEW DUAL ELECTRIC METER NEW PILASTER FUR-OUT FOR NEW ADU ENTRY. NEW FACIAL OF NEW STRUCTURE MATCHING EXISTING MAIN HOUSE. ROOFING CLASS A ASPHALT SHINGLE ROOFING ICC ESR-1389 INSTALLATION: OVER (1) LAYERS OF 30LBS FELT UNDER-LAYMENT OVER PLYWOOD SHEATHING PER MANUFACTURE DIRECTION. CERTAINTEED ROOFING OR EQUAL GRAND MANOR, BROWNSTONE COLOR (CLOSE TO ORIGINAL ROOFING COLOR) 9 NEW GABLE VENTS 10 WATER HEATER ENCLOSURE DOOR WITH LOUVER. PAINTED TO MATCH ADU EXTERIOR DOOR'S COLOR. 1 3 2 4 12 TOP OF SLAB 0.00 10 ' - 1 " 4 12 10 ' - 1 " TO P P L A T E TOP OF TOP PLATE 10'-1" 14 ' - 4 " TOP OF SLAB 0.00 10 ' - 1 " TO P P L A T E TOP OF TOP PLATE 10'-1" 6' - 8 " 6' - 8 " TOP OF SLAB 0.00 TOP OF TOP PLATE 10'-1" 4 12 TOP OF SLAB 0.00 10 ' - 1 " 4 12 10 ' - 1 " TO P P L A T E TOP OF TOP PLATE 10'-1" 14 ' - 4 " 6' - 8 " 4 1 2 3 TYP. 3 TYP. 2 4 8 9 1 4 23 TYP. 6 5 23 TYP. 7 9 15 ' - 0 " 15 ' - 0 " 15 ' - 0 " 10 1 4 6 9' - 0 " 14 15 ' - 0 " 6' - 8 " AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 TOP OF SLAB 0.00 TOP OF TOP PLATE 8'-1" (MATCH EXISTING) 2 SECTION - MAIN HOUSE ADDITION 1/4"=1'-0" 1 SECTION - MAIN HOUSE ADDITION 1/4"=1'-0" 1 13 6 8 10 9 14 2 4 TYP. 5 7 A12.00 TYP. EXISTINGNEW ADDITION 11 R-38 11 R-15 14 11R-15 TOP OF SLAB 0.00 TOP OF TOP PLATE 8'-1" (MATCH EXISTING) 3 A12.00 TYP. EXISTINGNEW ADDITION 6 14 11R-15 3 A12.00 TYP. 1 5 11 R-38 7 A12.00 4 TYP. 13 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.INSULATION SHALL CONFORM TO FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF 2022 CBC PER T-24 3.LABELED SAFETY GLASS [CBC SECTION 2406.4] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 72" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 4.ALL LUMBER IN CONTACT W/ CONC. TO BE PRES. TREATED DOUGLAS FIR (P.T.D.F.) 5.REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 1 CONCRETE FLOOR SLAB 2 CONCRETE FOOTING 3 4 5 ROOF FRAMING 6 2X CEILING JOIST 7 2X STUDS @ 16" O.C. PER PLAN 8 (2) 2X TOP PLATES 9 2X BOTTOM PLATE 10 1x FASCIA BOARD - PAINTED. 11 12 13 14 INTERIOR FLOOR FINISH BATT INSULATION PER TITLE T.24: R-15 @ EXTERIOR WALLS, R-38 @ ROOF ATTIC. 2X BLOCKING KEY NOTES GENERAL NOTES DOOR / WINDOW PER PLAN CLASS A ROOFING MATERIAL - SEE MATERIAL SPECIFICATIONS, CRRC #0676-0017b EXTERIOR CEMENT PLASTER - SEE MATERIAL SPECIFICATIONS AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b @ a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2.INSULATION SHALL CONFORM TO FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF 2022 CBC. A.R-13 BATT INSULATION IN WALLS B.R-30 BATT INSULATION IN ATTIC AREA 3.LABELED SAFETY GLASS [CBC SECTION 2406.4] IS REQUIRED IN: A.TUB/SHOWER ENCLOSURE AND GLAZING WITHIN 60" FROM THE BOTTOM OF TUB/SHOWER B.WINDOWS ADJACENT TO A DOOR C.GLASS IN DOORS D.GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 4.ALL LUMBER IN CONTACT W/ CONC. TO BE PRES. TREATED DOUGLAS FIR (P.T.D.F.) 5.REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 1 CONCRETE FLOOR SLAB 2 CONCRETE FOOTING 3 4 5 ROOF FRAMING 6 2X CEILING JOIST 7 2X STUDS @ 16" O.C. PER PLAN 8 (2) 2X TOP PLATES 9 2X BOTTOM PLATE 10 2x12 FASCIA BOARD - PAINTED. 11 12 13 14 INTERIOR FLOOR FINISH BATT INSULATION: R-15 IN EXTERIOR WALLS, R-38 IN ROOF ATTIC. 2X BLOCKING DOOR / WINDOW PER PLAN CLASS A ROOFING MATERIAL - SEE MATERIAL SPECIFICATIONS EXTERIOR CEMENT PLASTER - SEE MATERIAL SPECIFICATIONS 6 1 3 A12.00 TYP. 8 A12.00 1 2 4 4 5 5 6 14 11R-15 13 14 8 7 10 3 6 8 7 13 11 R-15 11 R-15 6 2 TOP OF SLAB 0.00 TOP OF PLATE 10'-1" TOP OF SLAB 0.00 TOP OF PLATE 10'-1" 1'-0"1'-0" 10 ' - 1 " 4 12 4 12 3 A12.00 TYP. 11 R-38 11 R-15 11 R-38 AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 8 8 1 o s t o r o a a r e n r o e C A 9 2 8 4 0 T : 7 1 4 . 6 5 1 . 9 9 4 5 E : e s n 2 b @ a o o . o 06/27/2024 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1 2 7 5 6 8 9 10 11 12 AD D I T I O N T O M A I N H O U S E & N E W D E T A C H E D A D U 51 2 1 W . R o b e r t s D r . & # 2 S a n t a A n a C A 9 2 7 0 4 11 1 o s t o r o a a r e n r o e C A 9 2 4 0 T 7 1 4 . 6 5 1 . 9 9 4 5 E e s n 2 b a o o . o 06/27/2024 3 8 2 4 2 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 DETAIL SHEET NUMBER DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SYMBOLS LEGEND SDX X DETAIL NUMBER EXISTING FOOTING REBAR NEW SLAB/ FOOTING HOLDOWN SCHEDULE: SHEAR PANEL LENGTH AND NUMBER. SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. xx x'-x"X INDICATES HOLDOWN, SEE HOLDOWNS SCHEDULE HDU2 HDU4 HDU5 HOLDOWNSYM. HDQ8 POST SIZE H3 H4 H5 4X 4X 4X H8 REF. DETAIL 4/SD1 HDU11H9 HDU14H10 HDU8H7 6X 6X 6X 8X 1. HOLDOWN POST MINIMUM THICKNESS IS SHOWN ON SCHEDULE ABOVE. ACTUAL HOLDOWN POST SIZE IS INDICATED ON PLAN. HHDQ11H11 6X HHDQ14H12 8X FOUNDATION NOTES: 1. REFER TO S.0 SHEET FOR MORE INFO. 2. REFER TO DETAILS 4/SD1 FOR INSTALLATION OF HOLDOWNS. 3. FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/ DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. 4. CONTRACTOR SHALL VERIFY ALL EXISTING FOOTINGS AND NOTIFY TO ENG. OF RECORD FOR ALL DISCREPANCIES. 5. HOLDOWN ANCHORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 6. ALL HOLDOWN ANCHORS SHALL BE TIED IN PLACE PRIOR TO CALLING FOUNDATION INSPECTION. 7. SEE DETAIL 12/SD2 FOR PLATE NOTCHING & BORING. FOR PIPING THRU SILL & TOP PLATES OF SHEAR WALLS, CONTACT DONG ENGINEERING, INC. 8. THE HOLDOWN POST SIZE SHALL FOLLOW THE HOLDOWN SCHEDULE U.N.O. 9. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS TO HAVE 5/8" DIA. X MIN. 12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED MAX. 12" AWAY AND MIN. 4 1/2" FROM THE END OF THE SILL PLATES. MIN. (2) A.BS. PER SILL PLATE/SHEAR PANEL. SILL PLATE UNDER SHEAR WALLS OF UP TO 4'-0" IN LENGTH MUST BE CONTINUOUS. 10. ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH SIMPSON PHNW SERIES 0.145Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. 11. ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL(S). PAD SCHEDULE: 2'-0" SQ. X 18" DEEP PAD W/ (3) #4 E.W. BOTT. PAD TYPESYM. P2424 1 2 A B 8'-0" A H3H3 6'-6" A 8' - 0 " A8' - 0 " A 15 " 15" 15" (N) 5" THK. CONCRETE SLAB ON GRADE W/ #4 @ 12" O.C. EA.WAY @ MID DEPTH OVER 2" SAND OVER 10 MIL VAPOR BARRIER OVER 2" SAND OVER COMPACTED SOIL. 12 SD1 12 SD1 11 SD1 14 SD1 1 SD1 1 SD1 1 SD1 8 SD1 TYP. 15 SD1 15 SD1 (E) FOOTING (E) CONCRETE SLAB TO BE REMAINED W/ M P B 6 6 Z W/ M P B 6 6 Z 16 SD1 16 SD1 8'-5"9'-9" 24" SQ. x 30" DEPTH PAD FOOTING 11 ' - 9 " 4 x 6 4 x 6 4 x 6 (E)(E)(E) (E ) (E) (E) R1 R1 R1 C1 44 1 2 A B 8'-0" A 4444 6'-6" A 8' - 0 " A8' - 0 " A CO N T . 2 - 2 x 8 H I P 1 2- 2 x 8 C L G 2 6 x 8 C L G 3 44 44 224 224 224 224 CON T . 2 - 2 x 8 H I P AD D S I M P S T R A P M S T 4 8 CO N T . T O P P L A T E , T Y P . 2X R . R . W / E N 8 L= 6 ' - 0 " 4 SD3 K.P . 4 SD3 7 SD3 K.P . 7 SD3 K.P . 4 SD3 224 13 SD2 13 SD2 13 SD2 13 SD2 13 SD2 13 SD2 44 20 SD2 7 SD2 1 SD3 2 SD2 1 SD2 2 SD2 6 x 8 C L G 2X R.R. W/ EN 2X R.R. W/ EN 4 x 6 66 66 2X R . R . W / E N 6 x 6 DROP W/ EN 4 R1 17 SD2 17 SD2 W/ P C W/ E P C 5 11 SD2 13 SD3 SHEAR PANEL LENGTH AND NUMBER. SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. X SDX DETAIL NUMBER DETAIL SHEET NUMBER CALIFORNIA FRAMING BEAM NUMBER, REFER TO CALCULATIONS. LEGEND: INDICATES EXISTING ROOF RAFTER X FRAMING NOTES: 6X6 INDICATES BEAM SIZE (DFL HEADER/DROP) U.N.O. BEARING WALLS, SEE PLAN. INDICATES NEW ROOF RAFTER, SEE JOISTS TABLE xx x'-x" XX POST SIZE, SEE POST SCHEDULE. INDICATES CEILING JOISTS, SEE JOISTS TABLE 1. REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS S.0 FOR MORE INFORMATION. 3. HANGERS FOR FLUSH FRAMED MEMBERS SHALL BE SIMPSON STRONG-TIE AS FOLLOWS U.N.O.: 2. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST BE DRILLED CLEAN CUT W/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT PLATES. - 2x4's @ 16" o.c. maximum 14'-0" height - 2x6's @ 16" o.c. maximum 20'-0" height 5. BUILDING CODE 2308.9.1 BALLOON FRAMED WALLS (NON-BEARING) STUD HEIGHTS: 6.BEARING STUD HEIGHTS: - 2x4's @ 16" o.c. maximum 10'-0" height - 2x6's @ 16" o.c. maximum 16'-0" height 4. THE FOLLOWING TRIMMER SCHEDULE SHOULD BE USED FOR HEADERS IN BEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE APPLIED @ EACH END OF HEADER. CLEAR SPAN, L L ≤ 6'-0"6'-0" < L ≤ 10'-0" L ≥ 10'-0" 2 x 4 2-2 x 4 2-2X4 U.N.O. PER PLAN CONSTRUCTION KEY NOTES:X 7.DOUBLE TOP PLATE AT ALL SHEAR WALL LINES SHALL BE SPLICED PER DETAIL 16/SD2. ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) AND PROVIDE SOLID BLOCKING BETWEEN FLOOR1 PROVIDE SOLID BLOCKING UNDER GIRDER / BEAM. LINE OF 2X BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. 2 3 STRAPS SCHEDULE: XPOST SCHEDULE: POST SIZESYM. 24 224 324 26 226 2X4 STUD (2)-2X4 BUNDLED STUD (3)-2X4 BUNDLED STUD 2X6 STUD (2)-2X6 BUNDLED STUD 326 44 46 66 (3)-2X6 BUNDLED STUD 4X4 POST 4X6 POST 6X6 POST POST SIZESYM. JOISTS TABLE: MARK JOIST SPECIFICATIONS R1 C1 CEILING JOIST 2 x 6 DFL#2 @ 16" O.C. MARK STRAP STRAP LENGTH NAILS/ SPACING REFERENCE DETAIL 8d BOX/SINKER @ 4-1/8" 8d BOX/SINKER @ 4-1/8" 16d SINKER @ 4-1/2" CS16 (2)CS16 CMSTC16 5 6 7 3' - 6" 3' - 6" 3' - 6" 9/SD2 CS16 (2)CS16 8 9 3' - 6" 3' - 6" 8d BOX/SINKER @ 2-1/16" O.C. 8d BOX/SINKER @ 2-1/16" O.C. 10/SD2 LUS FACE MOUNT TOP FLANGED HANGER TYPEMEMBER 2X JOIST 4X, 6X, LSL or PSL TJI I-JOIST JB HU W/ MAX.BA IUS ITS ROOF RAFTER 2 x 6 DFL#2 @ 16" O.C. RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 06/20/2024 PLAN CHECK1 S1 MAIN HOUSE FOUNDATION PLAN ROOF FRAMING PLAN SCALE: MAIN HOUSE - FOUNDATION PLAN 1/4" = 1'-0" SCALE: MAIN HOUSE - ROOF FRAMING PLAN 1/4" = 1'-0" 1 1 Lan Pham, RGE 686, Exp. 3-31-2025 01-13-2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 SHEAR PANEL LENGTH AND NUMBER. SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. X SDX DETAIL NUMBER DETAIL SHEET NUMBER CALIFORNIA FRAMING BEAM NUMBER, REFER TO CALCULATIONS. LEGEND: X FRAMING NOTES: 6X6 INDICATES BEAM SIZE (DFL HEADER/DROP) U.N.O. BEARING WALLS, SEE PLAN. INDICATES ROOF RAFTER, SEE JOISTS TABLE xx x'-x" XX POST SIZE, SEE POST SCHEDULE. INDICATES CEILING JOISTS, SEE JOISTS TABLE 1. REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS S.0 FOR MORE INFORMATION. 3. HANGERS FOR FLUSH FRAMED MEMBERS SHALL BE SIMPSON STRONG-TIE AS FOLLOWS U.N.O.: 2. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST BE DRILLED CLEAN CUT W/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT PLATES. - 2x4's @ 16" o.c. maximum 14'-0" height - 2x6's @ 16" o.c. maximum 20'-0" height 5. BUILDING CODE 2308.9.1 BALLOON FRAMED WALLS (NON-BEARING) STUD HEIGHTS: 6.BEARING STUD HEIGHTS: - 2x4's @ 16" o.c. maximum 10'-0" height - 2x6's @ 16" o.c. maximum 16'-0" height 4. THE FOLLOWING TRIMMER SCHEDULE SHOULD BE USED FOR HEADERS IN BEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE APPLIED @ EACH END OF HEADER. CLEAR SPAN, L L ≤ 6'-0"6'-0" < L ≤ 10'-0" L ≥ 10'-0" 2 x 4 2-2 x 4 2-2X4 U.N.O. PER PLAN CONSTRUCTION KEY NOTES:X 7.DOUBLE TOP PLATE AT ALL SHEAR WALL LINES SHALL BE SPLICED PER DETAIL 16/SD2. ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) AND PROVIDE SOLID BLOCKING BETWEEN FLOOR1 PROVIDE SOLID BLOCKING UNDER GIRDER / BEAM. LINE OF 2X BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. 2 3 STRAPS SCHEDULE: XPOST SCHEDULE: POST SIZESYM. 24 224 324 26 226 2X4 STUD (2)-2X4 BUNDLED STUD (3)-2X4 BUNDLED STUD 2X6 STUD (2)-2X6 BUNDLED STUD 326 44 46 66 (3)-2X6 BUNDLED STUD 4X4 POST 4X6 POST 6X6 POST POST SIZESYM. JOISTS TABLE: MARK JOIST SPECIFICATIONS R1 C1 CEILING JOIST 2 x 6 DFL#2 @ 16" O.C. MARK STRAP STRAP LENGTH NAILS/ SPACING REFERENCE DETAIL 8d BOX/SINKER @ 4-1/8" 8d BOX/SINKER @ 4-1/8" 16d SINKER @ 4-1/2" CS16 (2)CS16 CMSTC16 5 6 7 3' - 6" 3' - 6" 3' - 6" 9/SD2 CS16 (2)CS16 8 9 3' - 6" 3' - 6" 8d BOX/SINKER @ 2-1/16" O.C. 8d BOX/SINKER @ 2-1/16" O.C. 10/SD2 LUS FACE MOUNT TOP FLANGED HANGER TYPEMEMBER 2X JOIST 4X, 6X, LSL or PSL TJI I-JOIST JB HU W/ MAX.BA IUS ITS ROOF RAFTER 2 x 6 DFL#2 @ 16" O.C. RE F . ENTRY 200 AMP 1 2 A B 23'-4"25'-8" 11 ' - 1 " 15 " 4" TY P . 15 " 15 " 15" 4 SD1 TYP. 1 SD1 1 SD1 15" (N) 5" THK. CONCRETE SLAB ON GRADE W/ #4 @ 12" O.C. EA.WAY @ MID DEPTH OVER 2" SAND OVER 10 MIL VAPOR BARRIER OVER 2" SAND OVER COMPACTED SOIL. 1 SD1 2 SD1 1 SD1 8 SD1 TYP. P2 4 2 4 P2424 17 SD1 17 SD1 W/ C B S Q W/ CB S Q 11 ' - 1 " 2' - 9 " A H3 2' - 9 " A H3 2' - 9 " A H3 2' - 9 " A H3 3' - 6 " A H3 H3 6' - 3 " A H3 H3 12'-0" A 12'-0" A DETAIL SHEET NUMBER DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SDX X DETAIL NUMBER NEW SLAB/ FOOTING REBAR 2'-0" SQ. X 18" DEEP PAD W/ (3) #4 E.W. BOTT. PAD TYPESYM. SHEAR PANEL LENGTH AND NUMBER. SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. xx x'-x"X INDICATES HOLDOWN, SEE HOLDOWNS SCHEDULE P2424 1. REFER TO S.0 SHEET FOR MORE INFO. 2. REFER TO DETAILS 4/SD1 FOR INSTALLATION OF HOLDOWNS. 3. FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/ DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. 4. CONTRACTOR SHALL VERIFY ALL EXISTING FOOTINGS AND NOTIFY TO ENG. OF RECORD FOR ALL DISCREPANCIES. 5. HOLDOWN ANCHORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 6. ALL HOLDOWN ANCHORS SHALL BE TIED IN PLACE PRIOR TO CALLING FOUNDATION INSPECTION. 7. SEE DETAIL 12/SD2 FOR PLATE NOTCHING & BORING. FOR PIPING THRU SILL & TOP PLATES OF SHEAR WALLS, CONTACT DONG ENGINEERING, INC. 8. THE HOLDOWN POST SIZE SHALL FOLLOW THE HOLDOWN SCHEDULE U.N.O. 9. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS TO HAVE 5/8" DIA. X MIN. 12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED MAX. 12" AWAY AND MIN. 4 1/2" FROM THE END OF THE SILL PLATES. MIN. (2) A.BS. PER SILL PLATE/SHEAR PANEL. SILL PLATE UNDER SHEAR WALLS OF UP TO 4'-0" IN LENGTH MUST BE CONTINUOUS. 10. ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH SIMPSON PHNW SERIES 0.145Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. 11. ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL(S). SYMBOLS LEGEND HOLDOWN SCHEDULE: FOUNDATION NOTES: PAD SCHEDULE: HDU2 HDU4 HDU5 HOLDOWNSYM. HDQ8 POST SIZE H3 H4 H5 4X 4X 4X H8 REF. DETAIL 4/SD1 HDU11H9 HDU14H10 HDU8H7 6X 6X 6X 8X 1. HOLDOWN POST MINIMUM THICKNESS IS SHOWN ON SCHEDULE ABOVE. ACTUAL HOLDOWN POST SIZE IS INDICATED ON PLAN. HHDQ11H11 6X HHDQ14H12 8X RE F . ENTRY 200 AMP 4 x 6 4 x 6 4 x 6 4 x 6 4 x 6 4 x 64 x 64 x 64 x 6 4 x 6 4 x 6 4 x 6 4 x 6 1 2 A B 4 x 6 CLG 44 44 44 44 44 44 44 44 4 x 6 5 1/4" x 16" PSL CLG 1 2 x 8 RIDGE BOARD 8 SD2 8 SD2 3 SD2 4 SD2 5 SD2 15 SD2 HI. LOW R1 R1 C1 C1 1 SD2 1 SD2 3 SD2 2 SD3 6 SD2 TYP. 46 46 2X PURLIN PER DETAILS 4,5/SD2. 2X PURLIN PER DETAILS 4,5/SD2. 18 SD2 W/ EC C Q 18 SD2 W/ EC C Q ST6236 2' - 9 " A 2' - 9 " A 2' - 9 " A 2' - 9 " A 3' - 6 " A 6' - 3 " A 12'-0" A 12'-0" A RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 06/20/2024 PLAN CHECK1 S2 ADU FOUNDATION PLAN ROOF FRAMING PLAN SCALE: ADU - ROOF FRAMING PLAN 1/4" = 1'-0" 1 1 SCALE: ADU - FOUNDATION PLAN 1/4" = 1'-0" Lan Pham, RGE 686, Exp. 3-31-2025 01-13-2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 DETAIL SHEET NUMBER DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SYMBOLS LEGEND SDX X DETAIL NUMBER EXISTING FOOTING REBAR NEW SLAB/ FOOTING HOLDOWN SCHEDULE: SHEAR PANEL LENGTH AND NUMBER. SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. xx x'-x"X INDICATES HOLDOWN, SEE HOLDOWNS SCHEDULE HDU2 HDU4 HDU5 HOLDOWNSYM. HDQ8 POST SIZE H3 H4 H5 4X 4X 4X H8 REF. DETAIL 4/SD1 HDU11H9 HDU14H10 HDU8H7 6X 6X 6X 8X 1. HOLDOWN POST MINIMUM THICKNESS IS SHOWN ON SCHEDULE ABOVE. ACTUAL HOLDOWN POST SIZE IS INDICATED ON PLAN. HHDQ11H11 6X HHDQ14H12 8X FOUNDATION NOTES: 1. REFER TO S.0 SHEET FOR MORE INFO. 2. REFER TO DETAILS 4/SD1 FOR INSTALLATION OF HOLDOWNS. 3. FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/ DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. 4. CONTRACTOR SHALL VERIFY ALL EXISTING FOOTINGS AND NOTIFY TO ENG. OF RECORD FOR ALL DISCREPANCIES. 5. HOLDOWN ANCHORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 6. ALL HOLDOWN ANCHORS SHALL BE TIED IN PLACE PRIOR TO CALLING FOUNDATION INSPECTION. 7. SEE DETAIL 12/SD2 FOR PLATE NOTCHING & BORING. FOR PIPING THRU SILL & TOP PLATES OF SHEAR WALLS, CONTACT DONG ENGINEERING, INC. 8. THE HOLDOWN POST SIZE SHALL FOLLOW THE HOLDOWN SCHEDULE U.N.O. 9. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS TO HAVE 5/8" DIA. X MIN. 12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED MAX. 12" AWAY AND MIN. 4 1/2" FROM THE END OF THE SILL PLATES. MIN. (2) A.BS. PER SILL PLATE/SHEAR PANEL. SILL PLATE UNDER SHEAR WALLS OF UP TO 4'-0" IN LENGTH MUST BE CONTINUOUS. 10. ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH SIMPSON PHNW SERIES 0.145Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. 11. ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL(S). PAD SCHEDULE: 2'-0" SQ. X 18" DEEP PAD W/ (3) #4 E.W. BOTT. PAD TYPESYM. P2424 1 2 A B 8'-0" A H3H3 6'-6" A 8' - 0 " A8' - 0 " A 15 " 15" 15" (N) 5" THK. CONCRETE SLAB ON GRADE W/ #4 @ 12" O.C. EA.WAY @ MID DEPTH OVER 2" SAND OVER 10 MIL VAPOR BARRIER OVER 2" SAND OVER COMPACTED SOIL. 12 SD1 12 SD1 11 SD1 14 SD1 1 SD1 1 SD1 1 SD1 8 SD1 TYP. 15 SD1 15 SD1 (E) FOOTING (E) CONCRETE SLAB TO BE REMAINED W/ M P B 6 6 Z W/ M P B 6 6 Z 16 SD1 16 SD1 8'-5"9'-9" 24" SQ. x 30" DEPTH PAD FOOTING 11 ' - 9 " 4 x 6 4 x 6 4 x 6 (E)(E)(E) (E ) (E) (E) R1 R1 R1 C1 44 1 2 A B 8'-0" A 4444 6'-6" A 8' - 0 " A8' - 0 " A CO N T . 2 - 2 x 8 H I P 1 2- 2 x 8 C L G 2 6 x 8 C L G 3 44 44 224 224 224 224 CON T . 2 - 2 x 8 H I P AD D S I M P S T R A P M S T 4 8 CO N T . T O P P L A T E , T Y P . 2X R . R . W / E N 8 L= 6 ' - 0 " 4 SD3 K.P . 4 SD3 7 SD3 K.P . 7 SD3 K.P . 4 SD3 224 13 SD2 13 SD2 13 SD2 13 SD2 13 SD2 13 SD2 44 20 SD2 7 SD2 1 SD3 2 SD2 1 SD2 2 SD2 6 x 8 C L G 2X R.R. W/ EN 2X R.R. W/ EN 4 x 6 66 66 2X R . R . W / E N 6 x 6 DROP W/ EN 4 R1 17 SD2 17 SD2 W/ P C W/ E P C 5 11 SD2 13 SD3 SHEAR PANEL LENGTH AND NUMBER. SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. X SDX DETAIL NUMBER DETAIL SHEET NUMBER CALIFORNIA FRAMING BEAM NUMBER, REFER TO CALCULATIONS. LEGEND: INDICATES EXISTING ROOF RAFTER X FRAMING NOTES: 6X6 INDICATES BEAM SIZE (DFL HEADER/DROP) U.N.O. BEARING WALLS, SEE PLAN. INDICATES NEW ROOF RAFTER, SEE JOISTS TABLE xx x'-x" XX POST SIZE, SEE POST SCHEDULE. INDICATES CEILING JOISTS, SEE JOISTS TABLE 1. REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS S.0 FOR MORE INFORMATION. 3. HANGERS FOR FLUSH FRAMED MEMBERS SHALL BE SIMPSON STRONG-TIE AS FOLLOWS U.N.O.: 2. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST BE DRILLED CLEAN CUT W/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT PLATES. - 2x4's @ 16" o.c. maximum 14'-0" height - 2x6's @ 16" o.c. maximum 20'-0" height 5. BUILDING CODE 2308.9.1 BALLOON FRAMED WALLS (NON-BEARING) STUD HEIGHTS: 6.BEARING STUD HEIGHTS: - 2x4's @ 16" o.c. maximum 10'-0" height - 2x6's @ 16" o.c. maximum 16'-0" height 4. THE FOLLOWING TRIMMER SCHEDULE SHOULD BE USED FOR HEADERS IN BEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE APPLIED @ EACH END OF HEADER. CLEAR SPAN, L L ≤ 6'-0"6'-0" < L ≤ 10'-0" L ≥ 10'-0" 2 x 4 2-2 x 4 2-2X4 U.N.O. PER PLAN CONSTRUCTION KEY NOTES:X 7.DOUBLE TOP PLATE AT ALL SHEAR WALL LINES SHALL BE SPLICED PER DETAIL 16/SD2. ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) AND PROVIDE SOLID BLOCKING BETWEEN FLOOR1 PROVIDE SOLID BLOCKING UNDER GIRDER / BEAM. LINE OF 2X BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. 2 3 STRAPS SCHEDULE: XPOST SCHEDULE: POST SIZESYM. 24 224 324 26 226 2X4 STUD (2)-2X4 BUNDLED STUD (3)-2X4 BUNDLED STUD 2X6 STUD (2)-2X6 BUNDLED STUD 326 44 46 66 (3)-2X6 BUNDLED STUD 4X4 POST 4X6 POST 6X6 POST POST SIZESYM. JOISTS TABLE: MARK JOIST SPECIFICATIONS R1 C1 CEILING JOIST 2 x 6 DFL#2 @ 16" O.C. MARK STRAP STRAP LENGTH NAILS/ SPACING REFERENCE DETAIL 8d BOX/SINKER @ 4-1/8" 8d BOX/SINKER @ 4-1/8" 16d SINKER @ 4-1/2" CS16 (2)CS16 CMSTC16 5 6 7 3' - 6" 3' - 6" 3' - 6" 9/SD2 CS16 (2)CS16 8 9 3' - 6" 3' - 6" 8d BOX/SINKER @ 2-1/16" O.C. 8d BOX/SINKER @ 2-1/16" O.C. 10/SD2 LUS FACE MOUNT TOP FLANGED HANGER TYPEMEMBER 2X JOIST 4X, 6X, LSL or PSL TJI I-JOIST JB HU W/ MAX.BA IUS ITS ROOF RAFTER 2 x 6 DFL#2 @ 16" O.C. RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 06/20/2024 PLAN CHECK1 S1 MAIN HOUSE FOUNDATION PLAN ROOF FRAMING PLAN SCALE: MAIN HOUSE - FOUNDATION PLAN 1/4" = 1'-0" SCALE: MAIN HOUSE - ROOF FRAMING PLAN 1/4" = 1'-0" 1 1 Lan Pham, RGE 686, Exp. 3-31-2025 01-13-2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 SD2 STRUCTURAL DETAILS 22X CEILING JOIST PER PLAN.Roof~3 3ROOF SHEATHING AND NAILING PER NAILING SCHDL.Roof~1 42X STUD PER PLAN.Wall~1 5FRAMING CLIP A35 @ 32" O.C. MAX.A-A35_F~2 6FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-A35_L~1 7SHEARWALL PER PLAN.Wall~2 92X CEILING JOIST PER PLAN.W-2X6~2 12X ROOF RAFTER PER PLAN.Roof~2 102X BEVELED BLK'G.Roof~4 112X BEVELED BLK'G.Roof~4 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 4. 2X STUD WALL PER PLAN. 5. FRAMING CLIP A35 @ 16" O.C. 6. FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 7. SHEARWALL PER PLAN. 8. BOUNDARY NAILS. 9. 2-2X CEILING JOIST. 10. 2X BEVELED BLK'G. 11. 2X C.J. @ 16" O.C. 12. DBL. TOP PLATE OR DROP BM. PER PLAN. 8BOUNDARY NAILS.N-10d~ 8BOUNDARY NAILS.N-10d~12DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 111 SHEAR TRANSFER 22X CEILING JOIST PER PLAN.Roof~3 32X STUD PER PLAN.Wall~1 42X BEVELED BLK'G.Roof~4 5ROOF SHEATHING AND NAILING PER NAILING SCHDL.Roof~1 6SHEARWALL PER PLAN.Wall~2 7FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_L~4 8FRAMING CLIP @ ALT. LOCATION.A-A35_L~3 9BOUNDARY NAILS.N-10d~ 106-16d COMMON NAILS @ EA. RAFTER AND CEILING JOIST.ROOF~11 11DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 12X ROOF RAFTER PER PLAN.ROOF~2 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. 2X STUD PER PLAN. 4. 2X BEVELED BLK'G. 5. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 6. SHEARWALL PER PLAN. 7. FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 8. FRAMING CLIP @ ALT. LOCATION. 9. BOUNDARY NAILS. 10. 6-16d COMMON NAILS @ EA. RAFTER AND CEILING JOIST. 11. DBL. TOP PLATE OR DROP BM. PER PLAN. 111 SHEAR TRANSFER 12X ROOF RAFTER PER PLAN.ROOF~2 22X CEILING JOIST PER PLAN.ROOF~3 32X CEILING JOIST OR BLK'G 42X STUD WALL PER PLAN.WALL~1 5SHEARWALL PER PLAN.WALL~2 6FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 6FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_L~4 7PROVIDE 2X STRUT @ 48" O.C. W/ A35 @ EA. END. 82X LEDGER W/ 2-16d @ 6" O.C. TO 2X BLK'G.MISC~2 82X LEDGER W/ 2-16d @ 6" O.C. TO 2X BLK'G.MISC~292X BLK'G @ 4'-0" O.C. 102 x 4 FLAT SPAN ACROSS MIN. 6 C.J. @ 8'-0" MAX. 11DBL. TOP PLATE.W-22X4~ 12ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 13CONT. PLYWOOD 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. 2X RIM OR BLK'G. 4. 2X STUD WALL PER PLAN. 5. SHEARWALL PER PLAN. 6. FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 7. PROVIDE 2X STRUT @ 48" O.C. W/ A35 @ EA. END. 8. 2X LEDGER W/ 2-16d @ 6" O.C. TO 2X BLK'G. 9. 2X BLK'G @ 4'-0" O.C. 10. 2 x 4 FLAT SPAN ACROSS MIN. 6 C.J. @ 8'-0" MAX. 11. DBL. TOP PLATE. 12. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 13. CONT. PLYWOOD 111 SHEAR TRANSFER 12X ROOF RAFTER PER PLAN.ROOF~2 22X CEILING JOIST PER PLAN.ROOF~3 32 x 4 BRACE @ 48" O.C., MAX. L = 8'-0"ROOF~5 42X PURLIN SAME SIZE AS RAFTER W/ 2-16d TO BRACE.ROOF~5 54-16d COMMON NAILS @ EA. RAFTER AND BRACE JOIST. 6FRAMING CLIP A34 AT EA. BRACE TO WD. BEAM. 7CEILING BEAM PER PLAN.ROOF~14 8SIMPSON APPROVED HANGER PER PLAN.H-HU46_L~1 8SIMPSON APPROVED HANGER PER PLAN.H-HU46_L~19SIMPSON STRAP CS16 @ 32" O.C., L=2'-6" 10ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. 2 x 4 BRACE @ 48" O.C., MAX. L=8'-0". 4. 2X PURLIN SAME SIZE AS RAFTER W/ 2-16d TO BRACE. 5. 4-16d COMMON NAILS @ EA. RAFTER AND BRACE JOIST. 6. SIMPSON A34 AT EA. BRACE TO WD. BEAM. 7. CEILING BEAM PER PLAN. 8. SIMPSON APPROVED HANGER PER PLAN. 9. SIMPSON STRAP CS16 @ 32" O.C. W/ END LENGTH L=11" MIN. 10. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 45 ° M I N . 111 CONNECTION DETAIL 45 ° M I N . 12X ROOF RAFTER PER PLAN.ROOF~2 22X CEILING JOIST PER PLAN.ROOF~3 42X PURLIN SAME SIZE AS RAFTER W/ 2-16d TO BRACE.ROOF~5 32 x 4 BRACE @ 48" O.C., MAX. L = 8'-0"ROOF~5 54-16d COMMON NAILS @ EA. RAFTER AND BRACE JOIST. 66-16d COMMON NAILS @ EA. RAFTER AND CEILING JOIST.ROOF~11 72X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5 82X CEILING 12" OVERLAP W/ 4-16d. 9DBL. TOP PLATE.W-22X4~10FRAMING CLIP LTP4 @ 48" O.C. MAX.A-LTP4_L~4 11ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. 2 x 4 BRACE @ 48" O.C., MAX. L = 8'-0" 4. 2X PURLIN SAME SIZE AS RAFTER W/ 2-16d TO BRACE. 5. 4-16d COMMON NAILS @ EA. RAFTER AND BRACE JOIST. 6. 3-16d TIE AT EA. BRACE. 7. 2X SOLE PLATE W/ 2-16d @ 16" O.C. 8. 2X CEILING 12" OVERLAP W/ 4-16d. 9. DBL. TOP PLATE. 10. FRAMING CLIP LTP4 @ 48" O.C. MAX. 11. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 12" 111 CONNECTION DETAIL 1ROOF TRUSS BY MFR., SEE PLAN.ROOF~13 22X BLK'G @ 48" O.C.WALL~73SIMPSON "DTC" @ 48" O.C. MAX.H-DTC~ 4JOIST OR TRUSS BOTT. CHORD.4JOIST OR TRUSS BOTT. CHORD. 3SIMPSON "DTC" @ 48" O.C. MAX.H-DTC~ 5NON BEARING WALL. 3/ 4 " , T Y P . 3/ 4 " , T Y P . 5NON BEARING WALL. 1. ROOF OR FLOOR SYSTEM OR TRUSSES BY MFR., SEE PLAN. 2. 2X BLK'G @ 48" O.C. 3. SIMPSON "DTC" @ 48" O.C. MAX. 4. JOIST OR TRUSS BOTT. CHORD. 5. NON BEARING WALL. 111 NON-BEARING WALL DETAIL 1BEAM PER PLAN. 1BEAM PER PLAN.1BEAM PER PLAN. 2DBL. TOP PLATE. 2DBL. TOP PLATE.2DBL. TOP PLATE.3SIMPSON STRAP MSTI36 OR ST6224 3SIMPSON STRAP MSTI36 OR ST6224 4SIMPSON (2)A35 @ TOP & BOTT. 4SIMPSON (2)A35 @ TOP & BOTT. 4SIMPSON (2)A35 @ TOP & BOTT. 5POST OR MULTI STUD PER PLAN.WALL~3 5POST OR MULTI STUD PER PLAN.5POST OR MULTI STUD PER PLAN. 6(3)16d EA. SIDE 6(3)16d EA. SIDE 7SILL PLATE. 1. BEAM PER PLAN. 2. DBL. TOP PLATE. 3. SIMPSON STRAP MSTI36 OR ST6224. 4. SIMPSON A34 AT EA. SIDE OF BEAM AND POST PER BEAM CONDITION. 5. POST OR MULTI STUD PER PLAN. 6. 2X STUD EA. SIDE OF BEAM W/ 16d @ 12" O.C. STAGGERED TO POST. ADD 3-16d EA. SIDE TO BM. 7. 2X SILL PLATE. NOTE: - ADD FILLER @ SIDE OF BEAM AS NEEDED. 1BEAM PER PLAN. 2DBL. TOP PLATE.4SIMPSON (2)A35 @ TOP & BOTT. 4SIMPSON (2)A35 @ TOP & BOTT. 4SIMPSON (2)A35 @ TOP & BOTT. 5POST OR MULTI STUD PER PLAN.WALL~3 7SILL PLATE. COND A: DROP BEAM COND B: TOP FLUSH BEAM COND C: BOTTOM FLUSH BEAM COND D: SIDE FLUSH BEAM 111 BEAM POCKET DETAIL A MSTA12 B (1) CS16 END LENGTHSTRAP TYPE - 1BEAM PER PLAN.1BEAM PER PLAN. 2SIMPSON STRAP EA. SIDE OF BEAM TO POST. 2SIMPSON STRAP EA. SIDE OF BEAM TO POST.2SIMPSON STRAP EA. SIDE OF BEAM TO POST.2SIMPSON STRAP EA. SIDE OF BEAM TO POST. 3POST PER PLAN.WALL~3 3POST PER PLAN.WALL~3 4ALT. TO MSTA12 STRAPS, USE 2X KING STUD EA. SIDE OF BEAM TO POST & NAIL W/ 16d @ 16" O.C. TO POST & MIN. 5-16d TO BM. 1. BEAM PER PLAN. 2. SIMPSON STRAP EA. SIDE OF BEAM TO POST. 3. POST PER PLAN. 4. ALT. TO MSTA12 STRAPS, USE 2X KING STUD EA. SIDE OF BEAM TO POST & NAIL W/ 16d @ 16" O.C. TO POST & MIN. 5-16d TO BM. NOTES: - ADD SHIMS AS REQUIRED. - IF THERE IS DBL. TOP PLATE BETWEEN BM. & POST, INCREASE LENGTH OF STRAP TO ACCOMMODATE. - FILL ALL STRAP HOLES W/ NAILS. (2) CS16C 1'-1" 1'-1" CAPACITY 1880# 3400# 6800# EQ . EQ . 111 CONNECTION DETAIL 4'-0" LAP MIN. 1MIN. TWO ROWS 16d, TOTAL (24) 16d @ TYP. PLATE SPLICES OR BREAKS. 2SIMPSON STRAP MSTA36. 3LOCATE STUD UNDER SPLICE OR PROVIDE 2X BLKG. ATTACHED TO ADJACENT STUD W/ (3) 16d EA. SIDE. 3LOCATE STUD UNDER SPLICE OR PROVIDE 2X BLKG. ATTACHED TO ADJACENT STUD W/ (3) 16d EA. SIDE. 4PLATE TO STUD NAILING PER C.B.C. MIN REQUIREMENTS. 1. MIN. TWO ROWS 16d, TOTAL (24) 16d @ TYP. PLATE SPLICES OR BREAKS. 2. SIMPSON STRAP MSTA36. 3. LOCATE STUD UNDER SPLICE OR PROVIDE 2X BLKG. ATTACHED TO ADJACENT STUD W/ (3) 16d EA. SIDE. 4. PLATE TO STUD NAILING PER C.B.C. MIN REQUIREMENTS. NOTES: - FULLY NAIL STRAP W/ 16d SINKER OR 10d COMMON. - NAIL SHALL BE STAGGERED & AT LEAST 2 1/4" APART. 111 TOP PLATE SPLICE TYP. "W " M A X . "L" MAX.12" MIN.12" MIN. EQ . EQ . 1NOTCH LOCATION.2SIMPSON STRAP "MSTA36" W/ (11) 10d COMMON EA. END (STRAP NOT REQ'D AT SILL PLT.)3BORED HOLE. 1. NOTCH LOCATION. 2. SIMPSON STRAP "MSTA36" W/ (11) 10d COMMON EA. END (STRAP NOT REQ'D AT SILL PLT.) 3. BORED HOLE. NOTE: ONLY ONE NOTCH OR HOLE ALLOWED PER EA. STUD. ( EXCLUDING LET-IN BRACES). 2-2X TOP PLT. 2X OR 3X SILL PLATE. NOTCHES MIN. SPACING BORED HOLES "L" MAX. "W" MAX. 2X4 PLATE 2X6 PLATE 2X8 PLATE 6'-0" 6'-0" 6'-0" 3-1/2" 5-1/2" 5-1/2" 1-1/2" 2" 2" 1-1/4" 2" 3" 111 PLATE NOTCHING AND BORING 1PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN. 2FIELD NAILING PER PLAN.3CONTINUOUS PANEL EDGE, NO BLKG', E.N. PER PLAN. 1PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN. 4DISCONTINUOUS PANEL EDGE, E.N. PER PLAN. 5FRAMING @ 24" O.C. SHOWN (16" O.C. SIMILAR). 6DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT. 1. PANEL BOUNDARY & BOUNDARY NAILING (B.N.) PER PLAN. 2. FIELD NAILING PER PLAN. 3. CONTINUOUS PANEL EDGE, NO BLKG', E.N. PER PLAN. 4. DISCONTINUOUS PANEL EDGE, E.N. PER PLAN. 5. FRAMING @ 24" O.C. SHOWN (16" O.C. SIMILAR). 6. DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT. NOTES: - STAGGER JOINTS AS SHOWN. - MIN. SIZE OF SHEET SHALL BE 2 FT. x 2 FT. - NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING. - TOLERANCE ON NAILING SHALL BE 3/4" W/ THE AVERAGE NAIL SPACING OVER ANY 4 FT. LENGTH BEING AT LEAST THAT NOTED ON THE PLAN. 111 PLYWOOD SHEATHING LAYOUT END LE N G T H END LE N G T H 1TYPICAL ROOF RAFTER OR TOP CHORD OF TRUSS.2HIP BM. OR TOP CHORD OF HIP TRUSS. 3SIMPSON STRAP CS16 W/ 8d SINKER NAIL @ 2-1/16" O.C. CUT TO FIT OVERALL BAYS OF BLK'G WHERE APPLICABLE. 42X FLAT BLK'G W/ E.N., SEE PLAN FOR BLK'G LENGTH OR NO. OF BAYS. (MIN. 4 BAYS). END LENGTH 5DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~63SIMPSON STRAP CS16 W/ 8d SINKER NAIL @ 2-1/16" O.C. CUT TO FIT OVERALL BAYS OF BLK'G WHERE APPLICABLE. 1TYPICAL ROOF RAFTER OR TOP CHORD OF TRUSS. 1. TYPICAL ROOF RAFTER OR TOP CHORD OF TRUSS. 2. HIP BM. OR TOP CHORD OF HIP TRUSS. 3. SIMPSON STRAP CS16 W/ 8d SINKER NAIL @ 2-1/16" O.C. CUT TO FIT OVERALL BAYS OF BLK'G WHERE APPLICABLE. 4. 2X FLAT BLK'G W/ E.N., SEE PLAN FOR BLK'G LENGTH OR NO. OF BAYS. (MIN. 4 BAYS). 5. DBL. TOP PLATE OR DROP BM. PER PLAN. NOTES: * ADD 2" x 4" x 48" LONG MEMBER TO RECEIVE 2ND CS16 & NAIL W/ 16d @ 4" O.C. STAGGERED. STRAP 8 9 CS16 (2)CS16 END LENGTH 3'-6" 3'-6" CAPACITY 1700# NAILS/ SPACING 8d BOX/ SINKER @ 2-1/16" O.C. 3400#8d BOX/ SINKER @ 2-1/16" O.C. 111 DRAG DETAIL 111 DRAG DETAIL EQ.EQ. 1PLYWOOD SHEATHING W/ E.N. (TO EA. JOIST WHEN DBL. FLOOR JOISTS). 2FLUSH BEAM PER PLAN.FLOOR~4 3DBL. TOP PLATE. 4DROP BEAM PER PLAN.FLOOR~5 5STRAP PER CHART BELOW. 6ALT. STRAP LOCATION. 7SEE PLAN FOR BEARING CONDITION. 1. PLYWOOD SHEATHING W/ E.N. (TO EA. JOIST WHEN DBL. FLOOR JOISTS). 2. FLUSH BEAM PER PLAN. 3. DBL. TOP PLATE. 4. DROP BEAM PER PLAN. 5. STRAP PER CHART BELOW. 6. ALT. STRAP LOCATION. 7. SEE PLAN FOR BEARING CONDITION. STRAP CAPACITYEND LENGTH 5 6 CS16 (2)CS16 1700# 3400# 3'-6" 3'-6" 7 CMSTC16 4500#3'-6" NAILS/ SPACING 8d BOX/ SINKER @ 4-1/8" 8d BOX/ SINKER @ 4-1/8" 16d SINKER @ 4-1/2" 12X ROOF RAFTER PER PLAN.ROOF~2 22X CEILING JOIST PER PLAN.ROOF~3 22X CEILING JOIST PER PLAN.ROOF~3 12X ROOF RAFTER PER PLAN.ROOF~23DBL. TOP PLATE.W-22X4~ 42X STUD WALL PER PLAN.WALL~1 52X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5 62X BLK'G @ 4'-0" O.C.7ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 8SHEARWALL PER PLAN.WALL~2 9FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 10CEILING BEAM PER PLAN.ROOF~14 12BOUNDARY NAILS.N-8d~ 12BOUNDARY NAILS.N-8d~ 12BOUNDARY NAILS.N-8d~ 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. DBL. TOP PLATE. 4. 2X STUD WALL PER PLAN. 5. 2X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL. 6. 2X BLK'G @ 4'-0" O.C. 7. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 8. PLYWOOD TYPE "A" MIN. 9. FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 10. CEILING BEAM PER PLAN. 11. 2X MEMBER W/ 2-16d @ 16" O.C. TO STUD OR BM. 12. BOUNDARY NAILS. 12BOUNDARY NAILS.N-8d~ 11BOUNDARY NAILS.N-8d~ 11BOUNDARY NAILS.N-8d~ 111 SHEAR TRANSFER 12X ROOF RAFTER PER PLAN.ROOF~2 22X CEILING JOIST PER PLAN.ROOF~322X CEILING JOIST PER PLAN.ROOF~3 3DBL. TOP PLATE.W-22X4~ 42X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5 3DBL. TOP PLATE.W-22X4~ 52X STUD WALL PER PLAN.WALL~16SHEARWALL PER PLAN.WALL~2 7ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 7ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 8ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 6SHEARWALL PER PLAN.WALL~2 9BOUNDARY NAILS.N-10d~ 10FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 10FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~19BOUNDARY NAILS.N-10d~ 9BOUNDARY NAILS.N-10d~ 1. 2X ROOF RAFTER PER PLAN. 2. 2X CEILING JOIST PER PLAN. 3. DBL. TOP PLATE OR DROP BM. PER PLAN. 4. 2X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL. 5. 2X STUD WALL PER PLAN. 6. SHEARWALL PER PLAN. 7. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 8. ROOF SHEATHING W/ 2X R.R. PER CALIFORNIA FRAMING. 9. BOUNDARY NAILS. 10. FRAMING CLIP LTP4/ A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 12X ROOF RAFTER PER PLAN.ROOF~2 111 SHEAR TRANSFER 1RIDGE PER PLAN.ROOF~1522X ROOF RAFTER PER PLAN.ROOF~2 3ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 4A35 @ EA. RAFTER 5SIMPSON STRAP LSTA30 @ 32" O.C.6EDGE NAILING.MISC~3 1. RIDGE PER PLAN. 2. 2X ROOF RAFTER PER PLAN. 3. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 4. A35 @ EA. RAFTER 5. SIMPSON STRAP LSTA30 @ 32" O.C. 6. EDGE NAILING. 111 CONNECTION DETAIL 1CEILING/ FLUSH BEAM PER PLAN. 2POST PER PLAN.WALL~3 3HDR. PER PLAN.WALL~4 64X POST W/ (2) A35 AT TOP & (2) A35 AT BOTT. 7(2) A35 AT TOP CONNECT BEAM TO TOP PLATE.4DBL. TOP PLATE. 1. BEAM OR GIRDER TRUSS BOTTOM CHORD PER PLAN. 2. TRIMMER STUD PER PLAN. 3. HDR. PER PLAN. 4. DBL. TOP PLATE. 5. 2X CRIPPLE STUD WHERE OCCURRED. 6. 4X MIN. BLOCKING W/ (2) A34 AT TOP & BOTTOM. 7. A34 AT EA. SIDE OF BEAM TO TOP PLATE. 8. FOR TRUSS BOTTOM CHORD CONDITION, REPLACE (2) A34 W/ SIMPSON "LGT" GIRDER TIEDOWN (U.N.O.). 8CEILING/ FLUSH BEAM PER PLAN. 1CEILING/ FLUSH BEAM PER PLAN. 5(2) A35 AT TOP CONNECT BEAM TO TOP PLATE. 111 GIRDER TO HEADER CONNECTION 1SEE PLAN FOR HOLDOWN/ STRAP.1SEE PLAN FOR HOLDOWN/ STRAP. 1SEE PLAN FOR HOLDOWN/ STRAP.1SEE PLAN FOR HOLDOWN/ STRAP. 22 x 4 STUD (U.N.O.) 22 x 4 STUD (U.N.O.)22 x 4 STUD (U.N.O.) 22 x 4 STUD (U.N.O.) 3SHEARWALL PER PLAN.WALL~2 3SHEARWALL PER PLAN.WALL~2 3SHEARWALL PER PLAN.WALL~2 3SHEARWALL PER PLAN.WALL~2 4EDGE NAILING.MISC~3 4EDGE NAILING.MISC~34EDGE NAILING.MISC~3 4EDGE NAILING.MISC~3 4EDGE NAILING.MISC~3 4EDGE NAILING.MISC~3 516d @ 3" O.C. STAGGERED. 516d @ 3" O.C. STAGGERED. COND: "A"COND: "C" COND: "B"COND: "D" 1. SEE PLAN FOR SHEAR WALL HOLDOWN/ STRAP. 2. 2X STUD (U.N.O.) 3. SHEARWALL PER PLAN. 4. BOUNDARY NAILS. 5. 16d @ 3" O.C. STAGGERED. 111 SHEARWALL/WALL INTERSECTION 1WOOD BEAM PER PLAN. 1WOOD BEAM PER PLAN. 2SIMPSON APPROVED COLUMN CAP PER PLAN.CC-ECCQ~1 2SIMPSON APPROVED COLUMN CAP PER PLAN.CC-ECCQ~1 3WOOD POST OR BEAM PER PLAN. 3WOOD POST OR BEAM PER PLAN. 4SIMPSON STRAP "MST48". 1. WOOD BEAM PER PLAN. 2. SIMPSON APPROVED COLUMN CAP PER PLAN. 3. WOOD POST OR DROP BEAM PER PLAN. 4. SIMPSON STRAP "ST6236". ALT. LOCATION ON TOP OF BM. 5. PROVIDE SHIM UNDER AND @ THE SIDE OF THE SMALLER BM. AS REQUIRED. COND. A COND. B 1WOOD BEAM PER PLAN. 2SIMPSON APPROVED COLUMN CAP PER PLAN.CC-ECCQ~1 3WOOD POST OR BEAM PER PLAN.COND. C 1WOOD BEAM PER PLAN. 2SIMPSON APPROVED COLUMN CAP PER PLAN.CC-ECCQ~1 3WOOD POST OR BEAM PER PLAN. COND. D 5DECKING PER PLAN.FLOOR~2 4SIMPSON STRAP "MST48". 111 BEAM TO POST CONNECTION 1BM. PER PLAN CONT. OVER INTERMEDIATE POST. 1BM. PER PLAN CONT. OVER INTERMEDIATE POST. 1BM. PER PLAN CONT. OVER INTERMEDIATE POST. 2POST PER PLAN.WALL~32POST PER PLAN.WALL~3 2POST PER PLAN.WALL~3 2POST PER PLAN.WALL~3 2POST PER PLAN.WALL~3 3LTP4 ON TOP OF CORNER BEAMS. 41/2" DIA. LAG SCREW W/ 4" EMBED. INTO POST OR W/ 7" EMBED. FOR INVERT.41/2" DIA. LAG SCREW W/ 4" EMBED. INTO POST OR W/ 7" EMBED. FOR INVERT. 41/2" DIA. LAG SCREW W/ 4" EMBED. INTO POST OR W/ 7" EMBED. FOR INVERT. 41/2" DIA. LAG SCREW W/ 4" EMBED. INTO POST OR W/ 7" EMBED. FOR INVERT. 5BM. PER PLAN, MITER CUT @ CORNER POST. 5BM. PER PLAN, MITER CUT @ CORNER POST. 41/2" DIA. LAG SCREW W/ 4" EMBED. INTO POST OR W/ 7" EMBED. FOR INVERT. 6ALT. METHOD USE "PC", "BC" OR "AC" CONNECTOR, BM. CAN BE SPLICED ON POST.7ALT. METHOD USE "EPC", "BC" OR "LCE" @ CORNER CONDITION. 8RETURN BM. IF OCCURS. WILL NEED "W" TOP FLANGED HANGER OFFSET @ "EPC" & "BC". MAYBE MITER CUT W/ "LCE" ON EA. BM AS ALT. 1. BM. PER PLAN CONT. OVER INTERMEDIATE POST. 2. POST PER PLAN. 3. LTP4 ON TOP OF CORNER BEAMS. 4. 1/2" DIA. LAG SCREW W/ 4" EMBED. INTO POST OR W/ 7" EMBED. FOR INVERT. 5. BM. PER PLAN, MITER CUT @ CORNER POST. 6. ALT. METHOD USE "PC", "BC" OR "AC" CONNECTOR, BM. CAN BE SPLICED ON POST. 7. ALT. METHOD USE "EPC", "BC" OR "LCE" @ CORNER CONDITION. 8. RETURN BM. IF OCCURS. WILL NEED "W" TOP FLANGED HANGER OFFSET @ "EPC" & "BC". MAYBE MITER CUT W/ "LCE" ON EA. BM AS ALT. 111 BEAM TO STANDALONE POST FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 SD3 STRUCTURAL DETAILS 1FLUSH BEAM PER PLAN.FLOOR~4 1FLUSH BEAM PER PLAN.FLOOR~4 1FLUSH BEAM PER PLAN.FLOOR~4 2DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 2DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 3HDR. PER PLAN.WALL~4 2DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~6 4POST PER PLAN.WALL~3 4POST PER PLAN.WALL~3 5STRAP TYPE, SEE TABLE ABOVE. 5STRAP TYPE, SEE TABLE ABOVE. 5STRAP TYPE, SEE TABLE ABOVE. 6MIN. 4 x 8 SOLID BLK'G. END LENGTH EN D L E N G T H 7FOR "A", USE (2) ST12; FOR "B" USE (2) ST2122; FOR "C" USE (2) ST6224. 1. FLUSH BEAM PER PLAN. 2. DBL. TOP PLATE OR DROP BM. PER PLAN. 3. HDR. PER PLAN. 4. POST PER PLAN. 5. STRAP TYPE, SEE TABLE ABOVE. 6. MIN. 4 x 8 SOLID BLK'G. 7. FOR "A", USE (2) ST12; FOR "B" USE (2) ST2122; FOR "C" USE (2) ST6224. APPLICATION OF CS16 NOTES: - USE10d SINKER FOR MTS12 USE 10d COMMON NAILS FOR HTS20 USE 8d SINKER FOR CS16. - CUT CS STRAP TO MEET MIN. END LENGTH & USE (9) 8d @ EA. END OF EA. STRAP. - PROVIDE 1-1/2" SPACING BTWN ROWS OF NAILS @ MULTIPLE CS STRAPS. APPLICATION OF MTS & HTS STRAP TYPE (1) CS16 ON 2 x 4 (2) MTS12 LOAD CAP. A B C (2) CS16 ON 2-2 x 4 (3) CS16 ON 4 x 6 ALT. STRAP (2) HTS20 (4) HTS20 1700# SOLID WD. END LEN. EWP END LEN. 1'-6" 1'-6" 1'-6" 3'-6" 3'-6" 3'-6" 3400# 5100# 111 BEAM TO WALL CONNECTION 2-0" MIN. PANEL WIDTH 1SHEARWALL PER PLAN, REFERS TO SHEARWALL SCHEDULE. 2EDGE NAIL (E.N.) SHEAR PANEL TO ALL PANEL EDGES. 3FIELD NAIL @ 12" O.C. 4KING STUD OR POST PER PLAN. E.N. SHEAR PANEL TO POST. 5TRIMMER WHERE OCCURS. 8INSTALL HOLDOWN ON KING STUD OR POST W/ EDGE NAILING. 1. SHEAR PANEL PER PLAN. 2. EDGE NAIL (E.N.) SHEAR PANEL TO ALL SHEARWALL EDGES. WHEN PANEL EXTEND TO TRIMMER, E.N. BOTH TRIMMER AND KING STUDS. 3. FIELD NAIL @ 12" O.C. 4. 2X OR MULTIPLE KING STUD PER FRAMING NOTE W/ 16d @ 16" O.C. TO TRIMMER. 5. TRIMMER PER PLAN. 6. HEADER PER PLAN. 7. MIN. 3-16d TO END OF HEADER. 8. SIMPSON HOLDOWN PER PLAN. 9.WHEN HOLDOWNS CONNECTED TO KING STUD, REPLACED SDS SCREWS W/ LONGER LENGTH TO GET 2 1/2" PENETRATIONS TO TRIMMER.NOTES: 1. PROVIDE 3/8" EDGE DISTANCE FOR NAILS. 2. PROVIDE MIN. 2X BLK'G @ ALL PLYWOOD EDGES OR AS NOTED IN SHEAR SCHULE. 3. STAGGER NAILS THAT ARE SPACED 2" O.C. 4. FOR SPECIFIC SHEARWALL CONDITIONS, SEE PLAN & SCHEDULE. 5. NO CUTS OR HOLES IN SHEATHING WITHIN 16" OF CORNERS. 6. MAX. ACCUMULATED LENGTH OF OPENINGS SHALL NOT EXCEED 20% OF THE WALL LENGTH. MAX. LENGTH OF EA. OPENING IS 4-1/2" IN ANY DIRECTION. 6TRIMMER WHERE OCCURS. 7KING STUD OR POST PER PLAN. E.N. SHEAR PANEL TO POST. 9INSTALL HOLDOWN ON KING STUD OR POST W/ EDGE NAILING. 111 SHEAR PANEL ASSEMBLY DETAIL ℄ PANEL JOINT. 3/8" TYP. ℄ PANEL JOINT. 3/8" TYP. OFFSET EDGE SUPPORT OFFSET EDGE SUPPORT 1ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 1ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 2JOIST.32 x 4 W/ 16d @ 12" O.C. 42 x 4 FLAT W/ (2) 10d @ EA. END. 1. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 2. JOIST. 3. 2 x 4 W/ 16d @ 12" O.C. 4. 2 x 4 FLAT W/ (2) 10d @ EA. END. 111 BLOCKING AT EDGE SUPPORT 111 TYPICAL HEADER DETAIL 1HDR. PER PLAN.WALL~4 2(3) 16d COMMON FROM KING STUD TO HEADER, TYP. 3SIMPSON A35 @ T&B EA. END OF HEADER AT ALL EXTERIOR WALLS AT OPENINGS WIDER THAN 8'-0" 4SIMPSON LTP4 ALT. TO A35. INSTALL EA. SIDE OF HEADER. 5(2) 16d @ 2X4 WALL, (3) 16d @ 2X6 & 2X8 WALL. 1. HDR. PER PLAN. 2. (3) 16d COMMON FROM KING STUD TO HEADER, TYP. 3. SIMPSON A35 @ T&B EA. END OF HEADER AT ALL EXTERIOR WALLS AT OPENINGS WIDER THAN 8'-0" 4. SIMPSON LTP4 ALT. TO A35. INSTALL EA. SIDE OF HEADER. 5. (2) 16d @ 2X4 WALL, (3) 16d @ 2X6 & 2X8 WALL. 12X ROOF RAFTER PER PLAN.ROOF~2 22X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5 3ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 4FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 5SHEARWALL PER PLAN.WALL~2 4FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 6ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 72X ROOF RAFTER OR TRUSS @ MAIN ROOF FRAMING (TYP.) 2X 6 R I D G E ( U . N . O . ) VAL L E Y 2X F L A T VAL L E Y 2X F L A T C B A B 82X R.R. @ CALIF. FRAMING @ 16" O.C., IMTERMEDIATE SUPPORT @ 8'-0" O.C. MAX. PER DETAIL C SCALE: DETAIL A: CALIF. ROOF @ SHEARWALL NTS SCALE: CALIF. FRAMING (PLAN VIEW) NTS SCALE: DETAIL B: CALIF. ROOF TO MAIN ROOF NTS SCALE: DETAIL C: CALIF. RIDGE NTS 6ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 3ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 12X ROOF RAFTER PER PLAN.ROOF~2 92X CONT. W 2-16d @ 24" O.C. TOE NAIL TO TRUSSES OR @ 16" O.C. TOE NAIL TO R.R. 102X FULL DEPTH BLOCKING.W-B2X6~1 6ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 112X6 RIDGE BM. W/ 2-16d TOE NAIL TYP. EA. FACE AND EA. SIDE 122X6 PURLIN & 2X4 BRACE @ 9'-0" O.C. AND @ 8'-0" O.C. TO LIMIT R.R. TO 8'-0" SPAN MAX. 1. 2X ROOF RAFTER OR TRUSS PER PLAN. 2. 2X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL. 3. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 4. FRAMING CLIP A35/ LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 5. SHEARWALL PER PLAN. CONT. PLYWOOD SHEATHING SAME TYPE AS SHEARWALL BELOW TO CALIF. FRAMING. 6. ROOF SHEATHING W/ CALIFORNIA FRAMING. 7. 2X4 ROOF RAFTER OR TRUSS @ MAIN ROOF FRAMING (TYP.) 8. 2X R.R. @ CALIF. FRAMING @ 16" O.C., IMTERMEDIATE SUPPORT @ 8'-0" O.C. MAX. PER DETAIL C 9. 2X CONT. W 2-16d @ 24" O.C. TOE NAIL TO TRUSSES OR @ 16" O.C. TOE NAIL TO R.R. 10. 2X FULL DEPTH BLOCKING. 11. 2X6 RIDGE BM. W/ 2-16d TOE NAIL TYP. EA. FACE AND EA. SIDE 12. 2X6 PURLIN & 2X4 BRACE @ 9'-0" O.C. AND @ 8'-0" O.C. TO LIMIT R.R. TO 8'-0" SPAN MAX. 13. BOUNDARY NAILS. 5SHEARWALL PER PLAN.WALL~2 13ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 13ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 13ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 13ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 13ROOF SHEATHING W/ CALIFORNIA FRAMING.ROOF~8 111 CALIFORNIA FRAMING DETAIL 1HIP OR VALLEY2SIMPSON TWISTED STRAP MTS20 3KING POST PER PLAN. 4A34 @ EA. SIDE OF POST 5 1. HIP OR VALLEY BEAM. 2. SIMPSON TWISTED STRAP MTS20. 3. KING POST 4X MIN. PER PLAN. 4. A34 @ EA. SIDE OF POST. 5. DBL. C.J. OR DBL. TOP PLATE.. 111 CONNECTION DETAIL EQ.EQ. 12X ROOF RAFTER PER PLAN.ROOF~22HIP BM. PER PLAN. 32X BLK'G 4SIMPSON STRAP ST18 @ 4'-0" O.C. 1. 2X ROOF RAFTER PER PLAN. 2. HIP BM. PER PLAN. 3. 2X BLK'G 4. SIMPSON STRAP ST18 @ 4'-0" O.C. U.N.O. 111 CONNECTION DETAIL 1RIDGE PER PLAN.ROOF~15 2HIP BM PER PLAN. 3POST PER PLAN.WALL~3 4SIMPSON POST CAP "LPC4" W/ FASTENERS PER MFR.CC-LPC4~2 5A35 @ EA. SIDE OF KING POST. 6DOUBLE TOP PLATE OR DBL. JOISTS. 2HIP BM PER PLAN. 2HIP BM PER PLAN. 1RIDGE PER PLAN.ROOF~15 7SIMPSON "LSSR" HANGER. 8DBL. TOP PLATE OR DROP BM. PER PLAN.WALL~69SIMPSON "HCP" CONNECTOR 1. RIDGE PER PLAN. 2. HIP BM PER PLAN. 3. POST PER PLAN. 4. SIMPSON POST CAP "LPC4" W/ FASTENERS PER MFR. 5. A34 @ EA. SIDE OF KING POST. 6. DOUBLE TOP PLATE OR DBL. JOISTS. 7. SIMPSON "LSSR" HANGER. 8. DBL. TOP PLATE OR DROP BM. PER PLAN. 9. SIMPSON "HCP" CONNECTOR. 111 CONNECTION DETAIL 12X ROOF RAFTER PER PLAN.ROOF~2 2DBL. TOP PLATE.W-22X4~12X ROOF RAFTER PER PLAN.ROOF~2 32X CEILING JOIST PER PLAN.ROOF~3 32X CEILING JOIST PER PLAN.ROOF~3 42X BLK'G @ 4'-0" O.C. 52X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL.WALL~5 2DBL. TOP PLATE.W-22X4~ 62X LEDGER W/ 2-16d @ 6" O.C. TO 2X BLK'G.MISC~2 7FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 8ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 8ROOF SHEATHING AND NAILING PER NAILING SCHDL.ROOF~1 10BOUNDARY NAILS.N-8d~ 10BOUNDARY NAILS.N-8d~ 11SHEARWALL PER PLAN.WALL~2 1. 2X ROOF RAFTER PER PLAN. 2. DBL. TOP PLATE OR DROP BM. PER PLAN. 3. 2X CEILING JOIST PER PLAN. 4. 2X BLK'G @ 4'-0" O.C. 5. 2X SOLE PLATE W/ 16d @ 6" O.C. U.N.O., SEE NAILING PER SHEARWALL SCHDL. 6. 2X MEMBER W/ 2-16d @ EA. STUD. 7. FRAMING CLIP A35 PER SHEARWALL SCHDL. @ 48" O.C. MAX. 8. ROOF SHEATHING AND NAILING PER NAILING SCHDL. 9. FRAMING CLIP @ ALT. LOCATION. 10. BOUNDARY NAILS. 11. SHEARWALL PER PLAN. 12. 2X STUD WALL PER PLAN. 13. PLYWOOD SAME TYPE AS SHEARWALL BELOW. 10BOUNDARY NAILS.N-8d~ 122X STUD WALL PER PLAN.WALL~1 122X STUD WALL PER PLAN.WALL~1 10BOUNDARY NAILS.N-8d~ 10BOUNDARY NAILS.N-8d~ 7FRAMING CLIP LTP4 PER SHEARWALL SCHDL. @ 48" O.C. MAX.A-LTP4_BEND~1 9BOUNDARY NAILS.N-8d~ 13FLOOR SHEATHING AND NAILING PER NAILING SCHDL.FLOOR~1 111 SHEAR TRANSFER FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 06/20/2024 PLAN CHECK1 01/10/2024 PLAN CHECK2 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 RESTRICTIVE NOTICE DATE REVISIONS SHEET DESCRIPTION PROJECT OWNER PROJECT ADDRESS STAMP NO: REVISIONS THESE DESIGNS, DRAWINGS, AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF DONG ENGINEERING. THESE DRAWINGS CANNOT BE COPIED, TRANSFERRED, OR REPRODUCED NOR CAN ANY OTHER STRUCTURES BE BUILT FROM THEM WITHOUT WRITTEN CONSENT. SHEET DE#: TEL- 714-617-5979 GARDEN GROVE, CA 92841 7661 GARDEN GROVE BLVD., DONG ENGINEERING, INC. INFO@DONGENGINEERING.COM 240056 AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R & # 2 , S A N T A A N A C A 9 2 7 0 4 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 lanpham9@hotmail.com FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 GENERAL INFORMATION 01 Project Name 240056 - ADDITION 02 Run Title Title 24 Analysis 03 Project Location 5121 W.ROBERTS DR, 04 City SANTA ANA 05 Standards Version 2022 06 Zip code 92704 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft2)264 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)1094 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1358 19 Glazing Percentage (%)13.73% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0 10.51 0 12.67 0 -2.16 Space Cooling 0 81.95 0 75.88 0 6.07 IAQ Ventilation 0 0 0 0 0 0 Water Heating 0 41.03 0 41.03 0 0 Self Utilization/Flexibility Credit Efficiency Compliance Total 0 133.49 0 129.58 0 3.91 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 7.9 0 7.9 Appl. & Cooking 0 23.22 0 23.18 Plug Loads 0 48.04 0 48.04 Outdoor Lighting 0 1.69 0 1.69 TOTAL COMPLIANCE 0 214.34 0 210.39 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 30.98 30.94 0.04 0.13 Net EUI2 30.98 30.94 0.04 0.13 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •New ductwork added is less than 25 ft. in length HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Refrigerant Charge verification required if a refrigerant containing component is altered •Duct Sealing required if a duct system component, plenum, or air handling unit is altered BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 240056 - ADDITION 1358 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status (E) Living Conditioned HVAC1 1094 8 DHW Sys 1 Existing Unchanged 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Addition Conditioned HVAC1 264 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing Condition Front wall (E) Living R-0 Wall 180 Front 240 68 90 none Existing No Left wall (E) Living R-0 Wall 270 Left 200 0 90 none Existing No Rear wall (E) Living R-0 Wall 0 Back 160 62.5 90 none Existing No Right wall (E) Living R-0 Wall 90 Right 212 36 90 none Existing No Left wall 2 Addition R-15 Wall 270 Left 96 0 90 none New n/a Rear wall 2 Addition R-15 Wall 0 Back 176 36 90 none New n/a Right wall 2 Addition R-15 Wall 90 Right 96 4 90 none New n/a Interior front wall to ga (E) Living>>__Garag e__ Default Wall Prior to 197 n/a n/a 96 0 n/a Existing No Interior rear wall to add (E) Living>>Addition R-0 Wall1 n/a n/a 176 0 n/a New n/a Roof 2 (E) Living Default Roof Prior to 197 n/a n/a 1094 n/a n/a Existing No Roof 3 Addition R-38 Roof Attic n/a n/a 264 n/a n/a New n/a Front wall 2 __Garage__R-0 Wall 180 Front 160 16 90 none Existing No Left wall 3 __Garage__R-0 Wall 270 Left 156 112 90 none Existing No Rear Wall 3 __Garage__R-0 Wall 0 Back 56 0 90 none Existing No Right wall 3 __Garage__R-0 Wall 90 Right 156 0 90 none Existing No 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Status Verified Existing Condition Existing Construction Roof __Garage__R-0 Roof No Attic 0 Back 400 0 4 0.1 0.85 No Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic (E) Living Attic Roof(E) Living Ventilated 4 0.1 0.85 No No Existing No Attic Addition Attic RoofAddition Ventilated 4 0.1 0.85 No No New n/a FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition EW01.01 Window Front wall Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No EW01.02 Window Front wall Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No EW01.03 Window Front wall Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No W01.04 Window Rear wall Back 0 1 9 0.3 NFRC 0.23 NFRC Bug Screen New NA D01.04 Window Rear wall Back 0 1 53.5 0.3 NFRC 0.23 NFRC Bug Screen New NA W01.04 2 Window Right wall Right 90 1 16 0.3 NFRC 0.23 NFRC Bug Screen New NA EW01.07 Window Right wall Right 90 1 4 0.55 NFRC 0.67 NFRC Bug Screen Existing No EW01.05 Window Right wall Right 90 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition W01.01 Window Rear wall 2 Back 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen New NA W01.02 Window Rear wall 2 Back 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen New NA W01.03 Window Right wall 2 Right 90 1 4 0.3 NFRC 0.23 NFRC Bug Screen New NA EW01.06 Window Front wall 2 Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2)U-factor Status Verified Existing Condition DE 3068 Front wall 20 0.5 Existing No DG Left wall 3 112 0.7 Existing No SLAB FLOORS 01 02 03 04 05 06 07 08 09 10 Name Zone Area (ft2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Status Verified Existing Condition Slab-on-Grade (E) Living 1094 138 none 0 80%No Existing No Slab-on-Grade 2 Addition 264 68 none 0 80%No New n/a Slab-on-Grade 3 __Garage__400 80 none 0 0%No Existing No 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-0 Roof No Attic Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.484 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board Default Wall Prior to 197 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board R-0 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Attic Roof(E) Living Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofAddition Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Default Roof Prior to 197 Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-11 None / None 0.083 Over Ceiling Joists: R-1.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x6 @ 16 in. O. C.R-38 None / None 0.026 Over Ceiling Joists: R-23.7 insul. Cavity / Frame: R-14.3 / 2x6 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#)Status Verified Existing Condition Existing Water Heating System DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location Status Verified Existing Condition DHW Heater 1 Gas Small Storage 1 50 EF 0.6 Btu/Hr 75000 0 77 n/a Existing No 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Existing HVAC System HVAC1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 n/a Existing No HVAC - HEATING UNIT TYPES 01 02 03 04 05 Name System Type Number of Units Heating Efficiency Heating Unit Brand Heating Component 1 Central gas furnace 1 AFUE - 78 n/a HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER/SEER 9.5 10 Not Zonal Single Speed Cooling Component 1-hers-cool 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Status Verified Existing Condition Existing Distribution system New Ducts 25 ftSuppl y Retur n Suppl y Retur n Suppl y Retur n Air Distribution System 1 Unconditio ned attic Non- Verified R-6 R-6 Atti c Atti c n/a n/a No Bypass Duct Existing (not specified) Air Distribution System 1-hers-dist Existing + New No No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Not Required 0 HERS RATER VERIFICATION OF EXISTING CONDITIONS 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Truong Dong Dong Engineering 01/10/2025 10692 silver cir garden grove, CA 92843 (714) 204-2874 Truong Dong Dong Engineering 01/10/2025 10692 silver cir N/A garden grove, CA 92843 (714) 204-2874 425-P010009454A-000-000-0000000-0000 01/10/2025 16:28 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 GENERAL INFORMATION 01 Project Name 240056 - ADDITION 02 Run Title Title 24 Analysis 03 Project Location 5121 W.ROBERTS DR, 04 City SANTA ANA 05 Standards Version 2022 06 Zip code 92704 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft2)264 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)1094 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1358 19 Glazing Percentage (%)13.73% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0 10.51 0 12.67 0 -2.16 Space Cooling 0 81.95 0 75.88 0 6.07 IAQ Ventilation 0 0 0 0 0 0 Water Heating 0 41.03 0 41.03 0 0 Self Utilization/Flexibility Credit Efficiency Compliance Total 0 133.49 0 129.58 0 3.91 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 7.9 0 7.9 Appl. & Cooking 0 23.22 0 23.18 Plug Loads 0 48.04 0 48.04 Outdoor Lighting 0 1.69 0 1.69 TOTAL COMPLIANCE 0 214.34 0 210.39 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 30.98 30.94 0.04 0.13 Net EUI2 30.98 30.94 0.04 0.13 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •New ductwork added is less than 25 ft. in length HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Refrigerant Charge verification required if a refrigerant containing component is altered •Duct Sealing required if a duct system component, plenum, or air handling unit is altered BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 240056 - ADDITION 1358 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status (E) Living Conditioned HVAC1 1094 8 DHW Sys 1 Existing Unchanged 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Addition Conditioned HVAC1 264 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing Condition Front wall (E) Living R-0 Wall 180 Front 240 68 90 none Existing No Left wall (E) Living R-0 Wall 270 Left 200 0 90 none Existing No Rear wall (E) Living R-0 Wall 0 Back 160 62.5 90 none Existing No Right wall (E) Living R-0 Wall 90 Right 212 36 90 none Existing No Left wall 2 Addition R-15 Wall 270 Left 96 0 90 none New n/a Rear wall 2 Addition R-15 Wall 0 Back 176 36 90 none New n/a Right wall 2 Addition R-15 Wall 90 Right 96 4 90 none New n/a Interior front wall to ga (E) Living>>__Garag e__ Default Wall Prior to 197 n/a n/a 96 0 n/a Existing No Interior rear wall to add (E) Living>>Addition R-0 Wall1 n/a n/a 176 0 n/a New n/a Roof 2 (E) Living Default Roof Prior to 197 n/a n/a 1094 n/a n/a Existing No Roof 3 Addition R-38 Roof Attic n/a n/a 264 n/a n/a New n/a Front wall 2 __Garage__R-0 Wall 180 Front 160 16 90 none Existing No Left wall 3 __Garage__R-0 Wall 270 Left 156 112 90 none Existing No Rear Wall 3 __Garage__R-0 Wall 0 Back 56 0 90 none Existing No Right wall 3 __Garage__R-0 Wall 90 Right 156 0 90 none Existing No 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Status Verified Existing Condition Existing Construction Roof __Garage__R-0 Roof No Attic 0 Back 400 0 4 0.1 0.85 No Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic (E) Living Attic Roof(E) Living Ventilated 4 0.1 0.85 No No Existing No Attic Addition Attic RoofAddition Ventilated 4 0.1 0.85 No No New n/a FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition EW01.01 Window Front wall Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No EW01.02 Window Front wall Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No EW01.03 Window Front wall Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No W01.04 Window Rear wall Back 0 1 9 0.3 NFRC 0.23 NFRC Bug Screen New NA D01.04 Window Rear wall Back 0 1 53.5 0.3 NFRC 0.23 NFRC Bug Screen New NA W01.04 2 Window Right wall Right 90 1 16 0.3 NFRC 0.23 NFRC Bug Screen New NA EW01.07 Window Right wall Right 90 1 4 0.55 NFRC 0.67 NFRC Bug Screen Existing No EW01.05 Window Right wall Right 90 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition W01.01 Window Rear wall 2 Back 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen New NA W01.02 Window Rear wall 2 Back 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen New NA W01.03 Window Right wall 2 Right 90 1 4 0.3 NFRC 0.23 NFRC Bug Screen New NA EW01.06 Window Front wall 2 Front 180 1 16 0.55 NFRC 0.67 NFRC Bug Screen Existing No OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2)U-factor Status Verified Existing Condition DE 3068 Front wall 20 0.5 Existing No DG Left wall 3 112 0.7 Existing No SLAB FLOORS 01 02 03 04 05 06 07 08 09 10 Name Zone Area (ft2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Status Verified Existing Condition Slab-on-Grade (E) Living 1094 138 none 0 80%No Existing No Slab-on-Grade 2 Addition 264 68 none 0 80%No New n/a Slab-on-Grade 3 __Garage__400 80 none 0 0%No Existing No 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-0 Roof No Attic Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.484 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board Default Wall Prior to 197 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board R-0 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Attic Roof(E) Living Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofAddition Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Default Roof Prior to 197 Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-11 None / None 0.083 Over Ceiling Joists: R-1.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x6 @ 16 in. O. C.R-38 None / None 0.026 Over Ceiling Joists: R-23.7 insul. Cavity / Frame: R-14.3 / 2x6 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#)Status Verified Existing Condition Existing Water Heating System DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location Status Verified Existing Condition DHW Heater 1 Gas Small Storage 1 50 EF 0.6 Btu/Hr 75000 0 77 n/a Existing No 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Existing HVAC System HVAC1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 n/a Existing No HVAC - HEATING UNIT TYPES 01 02 03 04 05 Name System Type Number of Units Heating Efficiency Heating Unit Brand Heating Component 1 Central gas furnace 1 AFUE - 78 n/a HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER/SEER 9.5 10 Not Zonal Single Speed Cooling Component 1-hers-cool 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Status Verified Existing Condition Existing Distribution system New Ducts 25 ftSuppl y Retur n Suppl y Retur n Suppl y Retur n Air Distribution System 1 Unconditio ned attic Non- Verified R-6 R-6 Atti c Atti c n/a n/a No Bypass Duct Existing (not specified) Air Distribution System 1-hers-dist Existing + New No No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Not Required 0 HERS RATER VERIFICATION OF EXISTING CONDITIONS 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:240056 - ADDITION Calculation Date/Time:2024-02-06T04:13:41-08:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-02-06   04:14:12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Truong Dong Dong Engineering 02/06/2024 10692 silver cir garden grove, CA 92843 (714) 204-2874 Truong Dong Dong Engineering 02/06/2024 10692 silver cir N/A garden grove, CA 92843 (714) 204-2874 424-P010021597A-000-000-0000000-0000 02/06/2024 04:16 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 GENERAL INFORMATION 01 Project Name 240056 - ADU 02 Run Title Title 24 Analysis 03 Project Location 5121 W.ROBERTS DR, UNIT#2 04 City SANTA ANA 05 Standards Version 2022 06 Zip code 92704 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)90 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1000 19 Glazing Percentage (%)15.65% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type All electric 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 30.8 37.1 24 Proposed Design 30.1 35.8 23.4 0.7 1.3 0.6 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.02 kWdc •PV System resized to 2.02 kWdc (a factor of 2.016) to achieve 'Standard Design PV' PV scaling 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.36 1.7 0.99 7.17 -0.63 -5.47 Space Cooling 1 25.09 0.77 24.12 0.23 0.97 IAQ Ventilation 0.4 4.22 0.4 4.22 0 0 Water Heating 1.83 19.18 1.25 13 0.58 6.18 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 3.59 50.19 3.41 48.51 0.18 1.68 Photovoltaics -2.21 -66.47 -2.21 -65.93 Battery 0 0 Flexibility Indoor Lighting 0.86 8.06 0.86 8.06 Appl. & Cooking 2.62 20.93 2.6 20.69 Plug Loads 4.54 46.26 4.54 46.26 Outdoor Lighting 0.2 1.75 0.2 1.75 TOTAL COMPLIANCE 9.6 60.72 9.4 59.34 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 15.42 14.47 0.95 6.16 Net EUI2 4.18 3.23 0.95 22.73 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.02 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Ducts with high level of insulation •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Minimum Airflow •Fan Efficacy Watts/CFM •Verified HSPF •Verified heat pump rated heating capacity •Duct leakage testing •Verified Duct Design •Duct design specifies Buried Ducts •Compact distribution system expanded credit •Drain water heat recovery system BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 240056 - ADU 1000 1 2 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Conditioned HVAC1 1000 10 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front wall Living R-15 Wall 90 Front 290 50 90 Left wall Living R-15 Wall 180 Left 390 7.5 90 Rear wall Living R-15 Wall 270 Back 290 33 90 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Right wall Living R-15 Wall 0 Right 390 86 90 Roof Attic Living R-38 + R-13 Roof Attic n/a n/a 1000 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Attic RoofLiving Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W01.01 Window Front wall Front 90 1 18 0.3 NFRC 0.23 NFRC Bug Screen W 3040 Window Front wall Front 90 1 12 0.3 NFRC 0.23 NFRC Bug Screen W01.05 Window Left wall Left 180 1 7.5 0.3 NFRC 0.23 NFRC Bug Screen W 4640 Window Rear wall Back 270 1 18 0.3 NFRC 0.23 NFRC Bug Screen D 2068 Window Rear wall Back 270 1 15 0.3 NFRC 0.23 NFRC Bug Screen W01.04 Window Right wall Right 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.07 Window Right wall Right 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.09 Window Right wall Right 0 1 6 0.3 NFRC 0.23 NFRC Bug Screen D01.09 Window Right wall Right 0 1 44 0.3 NFRC 0.23 NFRC Bug Screen 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D01.01 Front wall 20 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Living 1000 135 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofLiving Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-13 None / 0 0.078 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-0.0 insul. R-38 + R-13 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a Expanded DHW Sys 1-hers-dhw DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem Rheem HPLD40-1RH Outside Living Living WATER HEATING - COMPACT DISTRIBUTION 01 02 03 04 05 06 07 Dwelling Unit type Water Heating System Name Master Bath distance of furthest fixture to Water Heater (ft) Kitchen distance of furthest fixture to Water Heater (ft) Furthest Third furthest fixture to Water Heater (ft) Compactness Factor HERS Verification Dwelling DHW Sys 1 n/a n/a n/a 0.6 Expanded Credit 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 WATER HEATING - DRAIN WATER HEAT RECOVERY 01 02 03 04 05 06 Dwelling Unit type DHW System and DWHR Names Installation Configuration Shower Drains Shower Drain Water Heat Recovery Efficiency (%)HERS Verification Dwelling DHW Sys 1 - 1 - DWHR-1 Equal Flow 2 43 Required WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Required Expanded Not Required Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF 10 17000 13500 EERSEER 14 12 Not Zonal Single Speed Heat Pump System 1-hers-htpump 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Not Required Not Required No Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Verified Design See duct design See duct design Attic Attic 4.93 0 No Bypass Duct Sealed and Tested Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Required Required Credit not taken Not Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.3 HVAC Fan 1-hers-fan 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.3 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 52 0.35 Exhaust No n/a / n/a No Yes 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2024-06-21T19:06:01-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-06-21   19:06:46 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Truong Dong Dong Engineering 06/21/2024 10692 silver cir garden grove, CA 92843 (714) 204-2874 Truong Dong Dong Engineering 06/21/2024 10692 silver cir N/A garden grove, CA 92843 (714) 204-2874 424-P010113219A-000-000-0000000-0000 06/21/2024 19:08 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 GENERAL INFORMATION 01 Project Name 240056 - ADU 02 Run Title Title 24 Analysis 03 Project Location 5121 W.ROBERTS DR, UNIT#2 04 City SANTA ANA 05 Standards Version 2022 06 Zip code 92704 07 Software Version EnergyPro 9.3 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1000 19 Glazing Percentage (%)12.30% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 35.6 36.2 26.6 Proposed Design 34.9 35.6 26.3 0.7 0.6 0.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.01 kWdc •PV System resized to 2.01 kWdc (a factor of 2.013) to achieve 'Standard Design PV' PV scaling 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.48 2.21 1.05 7.67 -0.57 -5.46 Space Cooling 0.95 23.24 0.65 22.28 0.3 0.96 IAQ Ventilation 0.4 4.22 0.4 4.22 0 0 Water Heating 1.83 19.35 1.33 14.08 0.5 5.27 Self Utilization/Flexibility Credit 0 0 0 0 Efficiency Compliance Total 3.66 49.02 3.43 48.25 0.23 0.77 Photovoltaics -2.21 -66.37 -2.21 -65.91 Battery 0 0 Flexibility 0 Indoor Lighting 0.86 8.06 0.86 8.06 Appl. & Cooking 5.02 31.31 5 31.07 Plug Loads 4.54 46.26 4.54 46.26 Outdoor Lighting 0.2 1.75 0.2 1.75 TOTAL COMPLIANCE 12.07 70.03 11.82 69.48 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 18.23 17.3 0.93 5.1 Net EUI2 7.01 6.08 0.93 13.27 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.01 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Verified HSPF •Verified heat pump rated heating capacity •Duct leakage testing •Compact distribution system expanded credit BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 240056 - ADU 1000 1 2 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Conditioned HVAC1 1000 10 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front wall Living R-15 Wall 0 Front 490 61 90 Left wall Living R-15 Wall 90 Left 220 36 90 Rear wall Living R-15 Wall 180 Back 490 14 90 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Right wall Living R-15 Wall 270 Right 220 56 90 Roof Attic Living R-38 + R-13 Roof Attic n/a n/a 1000 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Attic RoofLiving Ventilated 4 0.21 0.92 No Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W01.01 Window Front wall Front 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.02 Window Front wall Front 0 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.09 Window Front wall Front 0 1 5 0.3 NFRC 0.23 NFRC Bug Screen W01.03 Window Left wall Left 90 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.04 Window Left wall Left 90 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.05 Window Rear wall Back 180 1 9 0.3 NFRC 0.23 NFRC Bug Screen W01.06 Window Rear wall Back 180 1 5 0.3 NFRC 0.23 NFRC Bug Screen W01.07 Window Right wall Right 270 1 18 0.3 NFRC 0.23 NFRC Bug Screen W01.08 Window Right wall Right 270 1 14 0.3 NFRC 0.23 NFRC Bug Screen 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D01.01 Front wall 20 0.5 D01.09 Right wall 24 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Living 1000 142 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofLiving Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-13 None / 0 0.078 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-0.0 insul. R-38 + R-13 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a Expanded DHW Sys 1-hers-dhw DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem Rheem HPLD50-1RH Outside Living Living WATER HEATING - COMPACT DISTRIBUTION 01 02 03 04 05 06 07 Dwelling Unit type Water Heating System Name Master Bath distance of furthest fixture to Water Heater (ft) Kitchen distance of furthest fixture to Water Heater (ft) Furthest Third furthest fixture to Water Heater (ft) Compactness Factor HERS Verification Dwelling DHW Sys 1 n/a n/a n/a 0.6 Expanded Credit WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Required Expanded Not Required Not Required 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF 11 36000 30000 EERSEER 16 12 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Not Required Required Yes Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 1-hers-dist 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.3 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.3 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 52 0.35 Exhaust No n/a / n/a No Yes 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:240056 - ADU Calculation Date/Time:2025-01-10T16:53:39-08:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:1 STORY ADU NO GARAGE Z8.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-10   16:53:58 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Truong Dong Dong Engineering 01/10/2025 10692 silver cir garden grove, CA 92843 (714) 204-2874 Truong Dong Dong Engineering 01/10/2025 10692 silver cir N/A garden grove, CA 92843 (714) 204-2874 425-P010009481A-000-000-0000000-0000 01/10/2025 16:54 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering, Inc. 7661 GARDEN GROVE BLVD. , GARDEN GROVE, CA 92841 Office: (714) 617-5979 Email: info@dongengineering.com DATE:11/27/2024 CLIENT: JOB NO.:240056 Project: ADDITION + ADU STRUCTURAL CALCULATIONS FOR THE BUILDING AT: 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 1 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU Job#: 240056 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 Date: ROOF:SHINGLE Slope 4:12 Live Load 20 psf Roof'g Material 3.0 psf Sheathing 2.0 psf Trusses / Rafters 2.0 psf Ceiling Joists 2.0 psf Drywall 2.0 psf Sprinkler 0.5 psf Solar 3.0 psf Miscellaneous 0.5 psf Total D.L.15 psf Total Load 35 psf EXTERIOR WALL:INTERIOR WALL: EXTERIOR:9 DRYWALL:3 DRYWALL:3.0 DRYWALL:3.0 STUDS:2.0 STUDS:2.0 MISC.:1.0 MISC.:2.0 DL=15.0 PSF DL=10.0 PSF REVISIONS: 1 Sheets: Date: Init: Remark: 2 Sheets: Date: Init: Remark: 3 Sheets: Date: Init: Remark: 4 Sheets: Date: Init: Remark: 5 Sheets: Date: Init: Remark: 6 Sheets: Date: Init: Remark: LOADING CONDITIONS 6/21/2024 2 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 5121 W Roberts Dr, Santa Ana, CA 92704, USA Latitude, Longitude: 33.7352251, -117.936824 Date 2/5/2024, 8:45:12 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.333 MCER ground motion. (for 0.2 second period) S1 0.476 MCER ground motion. (for 1.0s period) SMS 1.6 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.066 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.571 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.685 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.333 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.45 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.878 Factored deterministic acceleration value. (0.2 second) S1RT 0.476 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.517 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.651 Factored deterministic acceleration value. (1.0 second) PGAd 0.772 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.571 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.919 Mapped value of the risk coefficient at short periods CR1 0.921 Mapped value of the risk coefficient at a period of 1 s CV 1.367 Vertical coefficient 3 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 DISCLAIMER While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. 4 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 W/H 2X 1X 1Y 2Y MAIN HOUSE - ROOF SHEARWALL LAYOUT 1 2 a b 5 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Job#: 240056 Date: 2/6/2024 PLAN: 1 CODE: CBC 2022 SECTION: 1X Number of Story: 1 Section width: 12(ft)Section length: 22(ft) Base height: 0(ft)Slope roof height: 12.5(ft)Gable mean roof height: 10.5(ft) WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS: Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1 Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1 B = 12(ft), L = 22(ft), H = 10.5(ft)-->L/B = 1.83, H/L = 0.48 Wall coefficient: Cpw = 0.8, Cpl = -0.33, Roof coefficient: Cpw = (-0.04;-0.48), Cpl = -0.57 Wind exposure = C-->anpha = 9.5, zg = 900 Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh) WIND LOAD: SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE: Light frame wood-->Rx = 6.5, Site class :D, SDS = 2FaSs/3 =1.066, SD1 = 2FvS1/3 =0, Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Rx = 0.7*1.066*1*W/6.5 = 0.1148*W Total Seismic Load = 60.84 = 60.84 PLF Redistrib: 530*8 = 4240 PLFxFT DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10 ROOF DIAPHRAGM Max shear = 86.91 x 12 / (2 x 22) = 23.7 PLF Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c. Chord force = 86.91 x 12^2 / (8 x 22) = 71.11 LBS Splice w/ min. (1) 16d sinker nails each side of splice at 8" o.c. (standard construction) (z, Kz, qz, P): (15, 0.85, 22.35, 21.53) ROOF Roof = 15*22 = 330 PLF Wall = 15*2*4 + 10*2*4 = 200 PLF Shear = 0.1148(330+200) = 0.1148*530 = 60.84 PLF Plate height: ROOF = 8(ft) SHEAR ROOF = 60.84*530*8/4240 = 60.84 PLF SHEAR ROOF = 0.6*W = 78.86(plf) ROOF 78.86 PLF WIND GOVERN 6 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Job#: 240056 Date: 2/6/2024 PLAN: 1 CODE: CBC 2022 SECTION: 1Y Number of Story: 1 Section width: 22(ft)Section length: 12(ft) Base height: 0(ft)Slope roof height: 12.5(ft)Gable mean roof height: 10.5(ft) WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS: Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1 Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1 B = 22(ft), L = 12(ft), H = 10.5(ft)-->L/B = 0.55, H/L = 0.88 Wall coefficient: Cpw = 0.8, Cpl = -0.5, Roof coefficient: Cpw = (-0.15;-0.72), Cpl = -0.59 Wind exposure = C-->anpha = 9.5, zg = 900 Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh) WIND LOAD: SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE: Light frame wood-->Ry = 6.5, Site class :D, SDS = 2FaSs/3 =1.066, SD1 = 2FvS1/3 =0, Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Ry = 0.7*1.066*1*W/6.5 = 0.1148*W Total Seismic Load = 32.14 = 32.14 PLF Redistrib: 280*8 = 2240 PLFxFT DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10 ROOF DIAPHRAGM Max shear = 45.91 x 22 / (2 x 12) = 42.08 PLF Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c. Chord force = 45.91 x 22^2 / (8 x 12) = 231.46 LBS Splice w/ min. (2) 16d sinker nails each side of splice at 8" o.c. (standard construction) (z, Kz, qz, P): (15, 0.85, 22.35, 24.7); (15, 0.85, 22.35, 15.2) ROOF Roof = 15*12 = 180 PLF Wall = 15*1*4 + 10*1*4 = 100 PLF Shear = 0.1148(180+100) = 0.1148*280 = 32.14 PLF Plate height: ROOF = 8(ft) SHEAR ROOF = 32.14*280*8/2240 = 32.14 PLF SHEAR ROOF = 0.6*W = 63.48(plf) ROOF 63.48 PLF WIND GOVERN 7 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Job#: 240056 Date: 2/6/2024 PLAN: 1 CODE: CBC 2022 SECTION: 2X Number of Story: 1 Section width: 27(ft)Section length: 42(ft) Base height: 0(ft)Slope roof height: 13(ft)Gable mean roof height: 10.5(ft) WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS: Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1 Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1 B = 12(ft), L = 22(ft), H = 10.5(ft)-->L/B = 1.83, H/L = 0.48 Wall coefficient: Cpw = 0.8, Cpl = -0.33, Roof coefficient: Cpw = (-0.04;-0.48), Cpl = -0.57 Wind exposure = C-->anpha = 9.5, zg = 900 Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh) WIND LOAD: SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE: Light frame wood-->Rx = 6.5, Site class :D, SDS = 2FaSs/3 =1.066, SD1 = 2FvS1/3 =0, Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Rx = 0.7*1.066*1*W/6.5 = 0.1148*W Total Seismic Load = 95.28 = 95.28 PLF Redistrib: 830*8 = 6640 PLFxFT DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10 ROOF DIAPHRAGM Max shear = 136.11 x 27 / (2 x 42) = 43.75 PLF Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c. Chord force = 136.11 x 27^2 / (8 x 42) = 295.31 LBS Splice w/ min. (2) 16d sinker nails each side of splice at 8" o.c. (standard construction) (z, Kz, qz, P): (15, 0.85, 22.35, 21.53) ROOF Roof = 15*42 = 630 PLF Wall = 15*2*4 + 10*2*4 = 200 PLF Shear = 0.1148(630+200) = 0.1148*830 = 95.28 PLF Plate height: ROOF = 8(ft) SHEAR ROOF = 95.28*830*8/6640 = 95.28 PLF SHEAR ROOF = 0.6*W = 81.88(plf) ROOF 95.28 PLF SEISMIC GOVERN 8 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 2 / 5 / 2 0 2 4 PL A N : 1 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 " | 4 * d * 1 . 4 = 0 . 0 3 " < 0 . 0 2 x 9 6 = 1 . 9 2 " 8. 0 0 4. 0 0 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) Ri g h t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) An c h o r B o l t 5/ 8 " x 1 2 " [2 ] sp a c e d e q u a l l y LI N E 1 ( D i r e c t i o n : Y ) @ F I R S T F L O O R | W i n d : 6 9 9 l b s | S e i s m i c : 3 5 4 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 1 2 f t | T o t a l S h e a r W a l l L e n g t h = 8 f t | S h e a r D i a p h r a g m = 5 8 p l f | D e s i g n S h e a r W a l l = 8 7 p l f ( W i n d ) / 4 4 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 1 . 8 / 1 . 8 ) = 1 . 8 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 2 . 5 / 2 . 5 ) = 2 . 5 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 8.00 ft P1 -23 3 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 9 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 2 / 5 / 2 0 2 4 PL A N : 1 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 " | 4 * d * 1 . 4 = 0 . 0 3 " < 0 . 0 2 x 9 6 = 1 . 9 2 " 8. 0 0 1. 5 0 2. 0 0 0. 2 5 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) Ri g h t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) An c h o r B o l t 5/ 8 " x 1 2 " [2 ] sp a c e d e q u a l l y LI N E 2 ( D i r e c t i o n : Y ) @ F I R S T F L O O R | W i n d : 6 9 9 l b s | S e i s m i c : 3 5 4 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 1 1 . 7 5 f t | T o t a l S h e a r W a l l L e n g t h = 8 f t | S h e a r D i a p h r a g m = 5 9 p l f | D e s i g n S h e a r W a l l = 8 7 p l f ( W i n d ) / 4 4 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 1 . 8 / 1 . 8 ) = 1 . 8 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 2 . 5 / 2 . 5 ) = 2 . 5 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 8.00 ft P1 -22 3 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 10 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 2 / 5 / 2 0 2 4 PL A N : 1 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 . 0 1 " | 4 * d * 1 . 4 = 0 . 0 3 " < 0 . 0 2 x 9 6 = 1 . 9 2 " 3. 5 0 5. 0 0 6. 5 0 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) Ri g h t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) An c h o r B o l t 5/ 8 " x 1 2 " [2 ] sp a c e d e q u a l l y 3. 7 5 P1 LI N E A ( D i r e c t i o n : X ) @ F I R S T F L O O R | W i n d : 4 7 4 l b s | S e i s m i c : 3 6 5 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 2 2 . 5 f t | T o t a l S h e a r W a l l L e n g t h = 6 . 5 f t | S h e a r D i a p h r a g m = 2 3 p l f | D e s i g n S h e a r W a l l = 7 3 p l f ( W i n d ) / 5 6 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 1 . 4 / 1 . 4 ) = 1 . 4 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 2 / 2 ) = 2 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 8.00 ft 3. 7 5 37 0 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 11 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 2 / 5 / 2 0 2 4 PL A N : 1 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 . 1 " | 4 * d * 1 . 4 = 0 . 5 6 " < 0 . 0 2 x 9 6 = 1 . 9 2 " 4. 5 0 4. 0 0 1. 0 0 7. 5 0 8. 0 0 3. 0 0 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n HD U 2 Po s t S i z e 4x 4 Te n s i o n ( k i p s ) 1. 6 Co m . ( k i p s ) 2. 1 Ri g h t S i d e Ho l d D o w n HD U 2 Po s t S i z e 4x 4 Te n s i o n ( k i p s ) 1. 6 Co m . ( k i p s ) 2. 1 An c h o r B o l t 5/ 8 " x 1 2 " [2 ] sp a c e d e q u a l l y 8. 2 5 2. 7 5 P1 LI N E B ( D i r e c t i o n : X ) @ F I R S T F L O O R | W i n d : 1 3 7 4 l b s | S e i s m i c : 1 6 5 1 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 4 2 . 2 5 f t | T o t a l S h e a r W a l l L e n g t h = 8 f t | S h e a r D i a p h r a g m = 5 6 p l f | D e s i g n S h e a r W a l l = 1 7 2 p l f ( W i n d ) / 2 0 6 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 1 . 8 / 1 . 8 ) = 1 . 8 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 2 . 5 / 2 . 5 ) = 2 . 5 k i p s ( S e c t . 4 . 3 . 3 . 4 . 1 ) Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 8.00 ft 3. 2 5 17 4 5 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 12 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Job#: 240056 Date: 2/5/2024 PLAN: 1 CODE: CBC 2022 Shear Wall (X-X Direction) Line Story Section Span Wind Seismic Added V (lb)H L v Type ###(ft)(plf)(plf)Wind Seismic (ft)(ft)(plf) A 1 1X 12 79 61 8 6.5 73 A B 1 1X 12 79 61 900 1286 8 8 206 A SUMMARY SHEAR WALL V2 = Seismic*Span/2 + Added Vseismic Line shear V = Maximum(V1;V2) V1 = Wind*Span/2 + Added Vwind v(plf) = V/L 13 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Job#: 240056 Date: 2/5/2024 PLAN: 1 CODE: CBC 2022 Shear Wall (Y-Y Direction) Line Story Section Span Wind Seismic Added V (lb)H L v Type ###(ft)(plf)(plf)Wind Seismic (ft)(ft)(plf) 1 1 1Y 22 63 32 8 8 87 A 2 1 1Y 22 63 32 8 8 87 A v(plf) = V/L Line shear V = Maximum(V1;V2) SUMMARY SHEAR WALL V1 = Wind*Span/2 + Added Vwind V2 = Seismic*Span/2 + Added Vseismic 14 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Job#: 240056 Date: 2/5/2024 PLAN: 1 CODE: CBC 2022 Wall Sec.Sto.Wind Seismic Span Offset Wind Seismic (#)(#)(#)v_(plf)v_(plf)(ft)(ft)V_(lb)V_(lb) 1 :Wind = 699(lb), Seismic = 354(lb) 1 1Y 1 63.5 32.1 22 698 354 l---------------22.0(ft)---------------l 2 :Wind = 699(lb), Seismic = 354(lb) 2 1Y 1 63.5 32.1 22 698 354 l---------------22.0(ft)---------------l A :Wind = 474(lb), Seismic = 365(lb) A 1X 1 78.9 60.8 12 473 365 l---------------12.0(ft)---------------l B :Wind = 1374(lb), Seismic = 1651(lb) B 1X 1 78.9 60.8 12 473 365 l---------------12.0(ft)---------------l B 2X 1 66.7 95.3 27 900 1286 l---------------27.0(ft)---------------l #N/A #N/A #N/A #N/A Description V_(lb)=v_(plf)*Span*Span/2/(Span+Offset) LATERAL p Factor: X Direction: p=1; Y Direction: p=1 15 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 Job #: 240056 Date : 06/21/2024 Plan : 1 BEAM : 1 - HIP AT BEDROOM Loads(Downward+) Beam Weight 5.5 plf from 0 ft to 15 ft Roof Rafter: (11+20)(10.5~0) = (DL=115.5~0PLF; LLr=210~0PLF) form 0 to 15 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 591/591 0 2 1702/1702 0 3 231/231 0 USE 2-2 x 8 Critcal Shear = -901 LB @5.5' 1.5xV/(F'v x A)= 0.26 F'v = 225, A = 22.5 Critcal Moment = -1156 LB-FT @5.5' M/(F'b x S)= 0.33 F'b = 1462, S = 28.12 Critical Deflection for TL = -0.049 INCH @ 10.5 L/240 = 0.475" Critical Deflection for LL = -0.029 INCH @ 10.5 L/360 = 0.317" 1 2 3 Moment Shear Deflection 5.5'9.5' BEAM : 2 - CLG AT BEDROOM Loads(Downward+) Beam Weight 5.5 plf from 0 ft to 11.75 ft Ceiling Joist DL: (4)(1.3) = (DL=5.3PLF) form 0 to 11.75 Point load @ 10.5 : Load from beam 1 at Support 1(P1) Point load @ 10.5 : Load from beam 1 at Support 1(P2) Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 189/189 0 2 1120/1120 0 USE 2-2 x 8 Critcal Shear = -1119 LB @11.75' 1.5xV/(F'v x A)= 0.33 F'v = 225, A = 22.5 Critcal Moment = 1391 LB-FT @10.5' M/(F'b x S)= 0.4 F'b = 1462, S = 28.12 Critical Deflection for TL = -0.155 INCH @ 6.5 L/240 = 0.588" Critical Deflection for LL = -0.082 INCH @ 6.5 L/360 = 0.392" 1 2 P1P2 Moment Shear Deflection 11.75' 16 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 Job #: 240056 Date : 06/21/2024 Plan : 1 BEAM : 3 - CLG AT BEDROOM Loads(Downward+) Beam Weight 10.1 plf from 0 ft to 11.75 ft Ceiling Joist DL: (4)(1.3) = (DL=5.3PLF) form 0 to 11.75 Point load @ 6.75 : Load from beam 1 at Support 2(P1) Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 815/815 0 2 1069/1068 0 USE 6 x 8 Critcal Shear = -1068 LB @11.75' 1.5xV/(F'v x A)= 0.18 F'v = 212, A = 41.25 Critcal Moment = 5149 LB-FT @6.75' M/(F'b x S)= 0.71 F'b = 1688, S = 51.56 Critical Deflection for TL = -0.332 INCH @ 6 L/240 = 0.588" Critical Deflection for LL = -0.194 INCH @ 6 L/360 = 0.392" 1 2 P1 Moment Shear Deflection 11.75' BEAM : 4 - DROP @ (E) PATIO Loads(Downward+) Beam Weight 7.4 plf from 0 ft to 18 ft Roof Rafter: (11+20)(6) = (DL=66PLF; LLr=120PLF) form 0 to 18 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 740/740 0 2 2182/2182 0 3 559/558 0 USE 6 x 6 Critcal Shear = -1145 LB @9.75' 1.5xV/(F'v x A)= 0.26 F'v = 212, A = 30.25 Critcal Moment = -1974 LB-FT @9.75' M/(F'b x S)= 0.5 F'b = 1688, S = 27.73 Critical Deflection for TL = -0.164 INCH @ 4.25 L/240 = 0.488" Critical Deflection for LL = -0.102 INCH @ 4.25 L/360 = 0.325" 1 2 3 Moment Shear Deflection 9.75'8.25' 17 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 Job #: 240056 Date : 06/21/2024 Plan : 1 BEAM : C1 - C.J. 2X6#2 @ 16" O.C. TYP. (MAX L=15'-0") Loads(Downward+) Ceiling Joist: (4+10)(1.3) = (DL=5.3PLF; LLr=13.4PLF) form 0 to 15 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 140/140 0 2 140/140 0 USE 2 x 6 Critcal Shear = 140 LB @0' 1.5xV/(F'v x A)= 0.11 F'v = 225, A = 8.25 Critcal Moment = 525 LB-FT @7.5' M/(F'b x S)= 0.49 F'b = 1682, S = 7.56 Critical Deflection for TL = -0.64 INCH @ 7.5 L/240 = 0.75" Critical Deflection for LL = -0.457 INCH @ 7.5 L/360 = 0.5" 1 2 Moment Shear Deflection 15' BEAM : R1 - R.R. 2X6#2 @ 16" O.C. TYP. (MAX L=12'-0") Loads(Downward+) Roof Rafter: (11+20)(1.3) = (DL=14.7PLF; LLr=26.7PLF) form 0 to 12 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 248/248 0 2 248/248 0 USE 2 x 6 Critcal Shear = 248 LB @0' 1.5xV/(F'v x A)= 0.2 F'v = 225, A = 8.25 Critcal Moment = 744 LB-FT @6' M/(F'b x S)= 0.7 F'b = 1682, S = 7.56 Critical Deflection for TL = -0.58 INCH @ 6 L/240 = 0.6" Critical Deflection for LL = -0.374 INCH @ 6 L/360 = 0.4" 1 2 Moment Shear Deflection 12' 18 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 WOOD COLUMN F 8' Cs = SDS / R = 1.066/1.5 = 0.711 F = CS x W = 0.711 x (12x19x0.011/2)/2 = 0.445 KIPS M = F x H = 0.445 x 8 = 3.56 k-ft 19 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Wood Column Dong Engineering IncLic. # : KW-06013880 DESCRIPTION:CANT. COLUMN AT PATIO Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: 240056 PATIO.ec6 Project Title: Engineer: Project ID: Printed: 10 JAN 2025, 2:49PM Project Descr: .Code References Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Wood Section Name 6x6Analysis Method : 8Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top Free, Bottom Fixed Wood Species Douglas Fir - Larch Wood Grade No.1 Fb +1,500.0 1,500.0 psi 1,000.0 1,000.0 180.0 1,000.0 33.0 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,400.0 1,400.0 1,700.0 1,400.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf.Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,700.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi NoMinimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 8 ft, K = 2.1 Unbraced Length for buckling ABOUT Y-Y Axis = 8 ft, K = 2.1 Brace condition for deflection (buckling) along columns : .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 55.458 lbs * Dead Load Factor AXIAL LOADS . . . BM2: Axial Load at 8.0 ft, D = 1.321, Lr = 2.160 k BM2: Axial Load at 8.0 ft, D = 0.840, Lr = 1.330 k BENDING LOADS . . . Lat. Point Load at 8.50 ft creating Mx-x, E = 0.720 k .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.8195 Location of max.above base 0.0 ft Applied Axial 2.547 k Applied Mx -4.032 k-ft Load Combination +1.149D+0.70E+H Load Combination +1.149D+0.70E+H Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 24.992 psi 288.0Allowable Shear psi 0.08678 : 1 Bending Compression Tension Location of max.above base 8.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0 k Bottom along Y-Y 0.720 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla111Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 1.979 in at 8.0 ft above base for load combination :E Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 732.72 psi Other Factors used to calculate allowable stresses . . . for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +D+H 0.900 PASS PASS0.0 0.0 8.0 ft0.674 ft0.1209 +D+L+H 1.000 PASS PASS0.0 0.0 8.0 ft0.635 ft0.1153 +D+Lr+H 1.250 PASS PASS0.0 0.0 8.0 ft0.550 ft0.2742 +D+S+H 1.150 PASS PASS0.0 0.0 8.0 ft0.582 ft0.1094 +D+0.750Lr+0.750L+H 1.250 PASS PASS0.0 0.0 8.0 ft0.550 ft0.2323 +D+0.750L+0.750S+H 1.150 PASS PASS0.0 0.0 8.0 ft0.582 ft0.1094 +D+0.60W+H 1.600 PASS PASS0.0 0.0 8.0 ft0.458 ft0.10 +1.149D+0.70E+H 1.600 PASS PASS0.0 0.08678 8.0 ft0.458 ft0.8195 20 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Wood Column Dong Engineering IncLic. # : KW-06013880 DESCRIPTION:CANT. COLUMN AT PATIO Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: 240056 PATIO.ec6 Project Title: Engineer: Project ID: Printed: 10 JAN 2025, 2:49PM Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +D+0.750Lr+0.750L+0.450W+H 1.600 PASS PASS0.0 0.0 8.0 ft0.458 ft0.2181 +D+0.750L+0.750S+0.450W+H 1.600 PASS PASS0.0 0.0 8.0 ft0.458 ft0.10 +1.112D+0.750L+0.750S+0.5250E+H 1.600 PASS PASS0.0 0.06508 8.0 ft0.458 ft0.6150 +0.60D+0.60W+0.60H 1.600 PASS PASS0.0 0.0 8.0 ft0.458 ft0.060 +0.4508D+0.70E+0.60H 1.600 PASS PASS0.0 0.08678 8.0 ft0.458 ft0.7582 . k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments +D+H 2.216 +D+L+H 2.216 +D+Lr+H 5.706 +D+S+H 2.216 +D+0.750Lr+0.750L+H 4.834 +D+0.750L+0.750S+H 2.216 +D+0.60W+H 2.216 +D+0.70E+H 2.2160.504 4.032 +D+0.750Lr+0.750L+0.450W+H 4.834 +D+0.750L+0.750S+0.450W+H 2.216 +D+0.750L+0.750S+0.5250E+H 2.2160.378 3.024 +0.60D+0.60W+0.60H 1.330 +0.60D+0.70E+0.60H 1.3300.504 4.032 D Only 2.216 Lr Only 3.490 L Only S Only W Only E Only 0.720 5.760 H Only .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance +D+H 0.0000 0.0000 0.000 ftftinin0.000 +D+L+H 0.0000 0.0000 0.000 ftftinin0.000 +D+Lr+H 0.0000 0.0000 0.000 ftftinin0.000 +D+S+H 0.0000 0.0000 0.000 ftftinin0.000 +D+0.750Lr+0.750L+H 0.0000 0.0000 0.000 ftftinin0.000 +D+0.750L+0.750S+H 0.0000 0.0000 0.000 ftftinin0.000 +D+0.60W+H 0.0000 0.0000 0.000 ftftinin0.000 +D+0.70E+H 0.0000 1.3853 8.000 ftftinin0.000 +D+0.750Lr+0.750L+0.450W+H 0.0000 0.0000 0.000 ftftinin0.000 +D+0.750L+0.750S+0.450W+H 0.0000 0.0000 0.000 ftftinin0.000 +D+0.750L+0.750S+0.5250E+H 0.0000 1.0389 8.000 ftftinin0.000 +0.60D+0.60W+0.60H 0.0000 0.0000 0.000 ftftinin0.000 +0.60D+0.70E+0.60H 0.0000 1.3853 8.000 ftftinin0.000 D Only 0.0000 0.0000 0.000 ftftinin0.000 Lr Only 0.0000 0.0000 0.000 ftftinin0.000 L Only 0.0000 0.0000 0.000 ftftinin0.000 S Only 0.0000 0.0000 0.000 ftftinin0.000 W Only 0.0000 0.0000 0.000 ftftinin0.000 E Only 0.0000 1.9789 8.000 ftftinin0.000 H Only 0.0000 0.0000 0.000 ftftinin0.000 . 21 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Wood Column Dong Engineering IncLic. # : KW-06013880 DESCRIPTION:CANT. COLUMN AT PATIO Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: 240056 PATIO.ec6 Project Title: Engineer: Project ID: Printed: 10 JAN 2025, 2:49PM Project Descr: Sketches 22 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Pole Footing Embedded in Soil Dong Engineering IncLic. # : KW-06013880 DESCRIPTION:PAD FOOTING FOR CANT. COL. Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: 220325 CANT. COLUMN.ec6 Project Title: Engineer: Project ID: Printed: 10 JAN 2025, 3:14PM Project Descr: Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Rectangular 24.0 250.0 1,500.0 Lateral Restraint at Ground Surface Pole Footing Shape Pole Footing Width . . . . . . . . . . . . .in Allow Passive . . . . . . . . . . . . . . . . . . . . . .pcf Max Passive . . . . . . . . . . . . . . . . . . . . . .psf Calculate Min. Depth for Allowable Pressures +1.149D+0.910E+0.60HGoverning Load Combination : Lateral Load 0.0 Moment 3.240 k-ft Minimum Required Depth 2.750 ft k Restraint @ Ground Surface Pressure at Depth Actual 645.60 psf Allowable 687.50 psf Surface Retraint Force 2,503.34 lbs Controlling Values ft^2Footing Base Area 4.0 Maximum Soil Pressure 0.8703 ksf k k k 1.321 k 2.160 k Applied Loads k Lateral Concentrated Load (k) D : Dead Load L : Live Lr : Roof Live S : Snow W : Wind E : Earthquake H : Lateral Earth Load distance above 8.0 k k k k k k k ft Lateral Distributed Loads (klf) TOP of Load above ground surface BOTTOM of Load above ground surface k/ft k/ft k/ft k/ft k/ft k/ft k/ft ft Applied Moment (kft) k-ft k-ft k-ft 0.0 k-ft k-ft 3.560 k-ft k-ft ground surface ft Vertical Load (k) k Load Combination Results Factor Soil IncreaseForces @ Ground Surface Load Combination Required Loads - (k)Moments - (ft-k)Depth - (ft) Pressure at Depth Allow - (psf)Actual - (psf) 0.00.000 0.000+D+H 0.13 1.00031.3 0.00.000 0.000+D+L+H 0.13 1.00031.3 0.00.000 0.000+D+Lr+H 0.13 1.00031.3 0.00.000 0.000+D+S+H 0.13 1.00031.3 0.00.000 0.000+D+0.750Lr+0.750L+H 0.13 1.00031.3 0.00.000 0.000+D+0.750L+0.750S+H 0.13 1.00031.3 0.00.000 0.000+D+0.60W+H 0.13 1.00031.3 0.00.000 0.000+D+0.750Lr+0.750L+0.450W+H 0.13 1.00031.3 0.00.000 0.000+D+0.750L+0.750S+0.450W+H 0.13 1.00031.3 23 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Pole Footing Embedded in Soil Dong Engineering IncLic. # : KW-06013880 DESCRIPTION:PAD FOOTING FOR CANT. COL. Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: 220325 CANT. COLUMN.ec6 Project Title: Engineer: Project ID: Printed: 10 JAN 2025, 3:14PM Project Descr: 0.00.000 0.000+0.60D+0.60W+0.60H 0.13 1.00031.3 645.60.000 3.240+1.149D+0.910E+0.60H 2.75 1.000687.5 585.90.000 2.430+1.112D+0.750L+0.750S+0.6825E+H 2.50 1.000625.0 645.60.000 3.240+0.4508D+0.910E+H 2.75 1.000687.5 24 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 6/21/2024 PLAN: 1 CODE: CBC 2022 1500 psf Trib Trib Wall Height DL(psf)LL(psf)roof(ft)DL(psf)LL(psf)floor(ft)DL(psf)wall(ft) 15 20 6 15 8 Roof:(DL+LL)(Trib) =210 plf Floor:(DL+LL)(Trib) =0 plf Wall:DL (Height)=120 plf 330 plf 330 /(15"/12)=264 psf< 1500 psf P(allowable) P(allowable) = 7,500 # 24 in FOUNDATION - 1-STORY Allowable soil bearing value: Roof Floor use 15" wide cont. ftg w/ 2-#4 top & bott. 45𝑜 25 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering, Inc. 7661 GARDEN GROVE BLVD. , GARDEN GROVE, CA 92841 Office: (714) 617-5979 Email: info@dongengineering.com DATE:11/27/2024 CLIENT: JOB NO.:240056 Project: ADDITION + ADU STRUCTURAL CALCULATIONS FOR THE BUILDING AT: 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 26 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU Job#: 240056 5121 W.ROBERTS DR, SANTA ANA, CA 92704 Date: 2/5/2024 RAFTER SHINGLE CEILING JOIST Slope 4:12 Live Load 20 psf Live Load 10 psf Roof'g Material 3 psf Self Weight 2.0 psf Sheathing 2.0 psf Drywall 2.0 psf Trusses / Rafters 2.0 psf Sprinkler 0.5 psf Solar 3.0 psf Miscellaneous 0.5 psf Total D.L.11 psf Total D.L.4 psf Total Load 31 psf Total Load 14 psf EXTERIOR WALL:INTERIOR WALL: EXTERIOR:9 DRYWALL:3 DRYWALL:3.0 DRYWALL:3.0 STUDS:2.0 STUDS:2.0 MISC.:1.0 MISC.:2.0 DL=15.0 PSF DL=10.0 PSF REVISIONS: 1 Sheets:Date: Init:Remark: 2 Sheets:Date: Init:Remark: 3 Sheets:Date: Init:Remark: 4 Sheets:Date: Init:Remark: 5 Sheets:Date: Init:Remark: 6 Sheets:Date: Init:Remark: LOADING CONDITIONS 27 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 A. General: Number of stories 1 Building risk category II Design Code CBC 2022 Load standard ASCE 7-16 ASCE 7-16 Design Load Combination ASD B. Lateral Loads Data: WIND STANDARD ASCE 7-16(Directional Procedure) Wind Exposure C Wind Speed 110 Enclosure Enclosed Building Velocity pressure qz = 0.00256KzKztKdKeV2 (26.10-1) Velocity pressure exposure coefficient Kz (Table 26.10-1) Directionality Factor Kd (Table 26.6-1) Topographic factor defined Kzt (26.8.2) Gust Effect Factor G (26.11.1) Pressures for MWFRS p = qGCp – qi(GCpi)(27.3-1) External pressure coefficient Cp (Fig. 27.3-1) Internal pressure coefficient Gcpi (Table 26.13-1) SEISMIC STANDARD ASCE 7-16(Equivalent Lateral Force Procedure) Seismic Design Category (Table 11.6-1) Importance factor I (Table 1.5-2) Soil Site Class D-Default (Table 20-3-1) Response modification coefficient R = 6.5 (Table 12.2-1) System overstrength coefficient Ω = 2.5 (Table 12.2-1) Approximate fundamental period parameters Ct = 0.02 x = 0.75 (Table 12.8-2) Building Height (ft)13 Building period T=Ta (sec) = 0.25 (Formula 12.8-7) Base Shear Adjustment Factor = 1 Seismic response coefficient Cs = 0.16 (Formula 12.8-2) BUILDING INFORMATION 28 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 1Y 1X 1 2 ADU - ROOF SHEARWALL LAYOUT A B RE F . ENTRY 200 AMP 29 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 SECTION: 1X Number of Story: 1 Section width: 22(ft)Section length: 49(ft) Base height: 0.75(ft)Slope roof height: 14.5(ft)Gable mean roof height: 12.5(ft) WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS: Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1 Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1 B = 22(ft), L = 49(ft), H = 13(ft)-->L/B = 2.23, H/L = 0.27 Wall coefficient: Cpw = 0.8, Cpl = -0.29 Wind exposure = C-->anpha = 9.5, zg = 900 Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh) WIND LOAD: SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE: Light frame wood-->Rx = 6.5, Site class :D, SDS = 2FaSs/3 =1.066, SD1 = 2FvS1/3 =0, Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Rx = 0.7*1.066*1*W/6.5 = 0.1148*W Total Seismic Load = 118.82 = 118.82 PLF Redistrib: 1035*10 = 10350 PLFxFT DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10 ROOF DIAPHRAGM Max shear = 169.74 x 22 / (2 x 49) = 38.1 PLF Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c. Chord force = 169.74 x 22^2 / (8 x 49) = 209.58 LBS Splice w/ min. (2) 16d sinker nails each side of splice at 8" o.c. (standard construction) (z, Kz, qz, P): (15, 0.85, 22.35, 20.68) ROOF Roof = 15*49 = 735 PLF Wall = 15*2*5 + 10*3*5 = 300 PLF Shear = 0.1148(735+300) = 0.1148*1035 = 118.82 PLF Plate height: ROOF = 10(ft) SHEAR ROOF = 118.82*1035*10/10350 = 118.82 PLF SHEAR ROOF = 0.6*W = 93.07(plf) ROOF 118.82 PLF SEISMIC GOVERN 30 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 SECTION: 1Y Number of Story: 1 Section width: 49(ft)Section length: 22(ft) Base height: 0.75(ft)Slope roof height: 14.5(ft)Gable mean roof height: 12.5(ft) WIND PARAMETERS PER ASCE7-16, CHAPTER 27, MWFRS BUILDINGS OF ALL HEIGHTS: Wind speed = 110, Wind exposure = C, Wind importance factor Iw = 1 Coefficients: Kd = 0.85, Kzt = 1, G = 0.85, Gcpi = +/-0.18, omega = 1 B = 49(ft), L = 22(ft), H = 13(ft)-->L/B = 0.45, H/L = 0.59 Wall coefficient: Cpw = 0.8, Cpl = -0.5, Roof coefficient: Cpw = (-0.09;-0.57), Cpl = -0.58 Wind exposure = C-->anpha = 9.5, zg = 900 Kz = 2.01*(15/zg)^(2/anpha)qz = 0.00256*Kz*Kzt*Kd*V^2*Iw P = G(Cpw*qz+Cpl*qh) WIND LOAD: SEISMIC PARAMETERS PER ASCE7-16, CHAPTER 12.8, ELF PROCEDURE: Light frame wood-->Ry = 6.5, Site class :D, SDS = 2FaSs/3 =1.066, SD1 = 2FvS1/3 =0, Seismic design category: D, I = 1, 0.7*V = 0.7*SDS*I*W/Ry = 0.7*1.066*1*W/6.5 = 0.1148*W Total Seismic Load = 60.84 = 60.84 PLF Redistrib: 530*10 = 5300 PLFxFT DIAPHRAGM & CHORD FORCE PER ASCE07-16 SECTION 12.10 ROOF DIAPHRAGM Max shear = 86.91 x 49 / (2 x 22) = 96.79 PLF Use: 15/32" apa rated unblock 32/16 w/8d common nails at 6", 6", 12" o.c. Chord force = 86.91 x 49^2 / (8 x 22) = 1185.63 LBS Splice w/ min. (7) 16d sinker nails each side of splice at 8" o.c. (standard construction) (z, Kz, qz, P): (15.25, 0.85, 22.43, 24.75); (15, 0.85, 22.35, 24.7) ROOF Roof = 15*22 = 330 PLF Wall = 15*2*5 + 10*1*5 = 200 PLF Shear = 0.1148(330+200) = 0.1148*530 = 60.84 PLF Plate height: ROOF = 10(ft) SHEAR ROOF = 60.84*530*10/5300 = 60.84 PLF SHEAR ROOF = 0.6*W = 101.09(plf) ROOF 101.09 PLF WIND GOVERN 31 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R # 2 , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 1 1 / 2 7 / 2 0 2 4 PL A N : 2 CO D E : C B C 2 0 2 2 W a l l Se c . St o . W i n d Se i s m i c Sp a n Of f s e t W i n d Se i s m i c (# ) (# ) (# ) v_ ( p l f ) v_ ( p l f ) (f t ) (f t ) V_ ( l b ) V_ ( l b ) 1 Ty p e A : W i n d = 2 4 7 7 ( l b ) , S e i s m i c = 1 4 9 1 ( l b ) 1 1Y 1 10 1 . 1 60 . 8 49 24 7 7 14 9 1 l- - - - - - - - - - - - - - - 4 9 . 0 ( f t ) - - - - - - - - - - - - - - - l 2 Ty p e A : W i n d = 2 4 7 7 ( l b ) , S e i s m i c = 1 4 9 1 ( l b ) 2 1Y 1 10 1 . 1 60 . 8 49 24 7 7 14 9 1 l- - - - - - - - - - - - - - - 4 9 . 0 ( f t ) - - - - - - - - - - - - - - - l A Ty p e A : W i n d = 1 0 2 4 ( l b ) , S e i s m i c = 1 3 0 7 ( l b ) A 1X 1 93 . 1 11 8 . 8 22 10 2 4 13 0 7 l- - - - - - - - - - - - - - - 2 2 . 0 ( f t ) - - - - - - - - - - - - - - - l B Ty p e A : W i n d = 1 0 2 4 ( l b ) , S e i s m i c = 1 3 0 7 ( l b ) B 1X 1 93 . 1 11 8 . 8 22 10 2 4 13 0 7 l- - - - - - - - - - - - - - - 2 2 . 0 ( f t ) - - - - - - - - - - - - - - - l #N / A #N / A #N / A #N / A #N / A #N / A De s c r i p t i o n V_ ( l b ) = v _ ( p l f ) * S p a n * S p a n / 2 / ( S p a n + O f f s e t ) LA T E R A L p F a c t o r : X D i r e c t i o n : p = 1 ; Y D i r e c t i o n : p = 1 32 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R # 2 , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 1 1 / 2 7 / 2 0 2 4 PL A N : 2 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 . 0 2 " | 4 * d * 1 . 4 = 0 . 1 3 " < 0 . 0 2 x 1 2 0 = 2 . 4 " 2. 7 5 2. 7 5 2. 7 5 2. 7 5 2. 7 5 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n HD U 2 HD U 2 Po s t S i z e 4x 4 4x 4 Up l i f t ( k i p s ) 1. 9 1. 9 Co m . ( k i p s ) 1. 8 1. 8 Ri g h t S i d e Ho l d D o w n HD U 2 HD U 2 Po s t S i z e 4x 4 4x 4 Te n s i o n ( k i p s ) 1. 9 1. 9 Co m . ( k i p s ) 1. 8 1. 8 An c h o r B o l t 5/ 8 " x 1 2 " [2 ] [2 ] sp a c e d e q u a l l y P4 P3 4. 5 0 Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 10.00 ft LI N E 1 ( D i r e c t i o n : Y ) @ F I R S T F L O O R | W i n d : 2 4 7 7 l b s | S e i s m i c : 1 4 9 1 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 2 2 . 7 5 f t | T o t a l S h e a r W a l l L e n g t h = 1 1 f t | S h e a r D i a p h r a g m = 1 0 9 p l f | D e s i g n S h e a r W a l l = 2 2 5 p l f ( W i n d ) / 1 3 6 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 0 . 6 / 0 . 6 ) + P 2 ( 0 . 6 / 0 . 6 ) + P 3 ( 0 . 6 / 0 . 6 ) + P 4 ( 0 . 6 / 0 . 6 ) = 2 . 4 k i p s ( S e c . 4 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 0 . 8 / 0 . 8 ) + P 2 ( 0 . 8 / 0 . 8 ) + P 3 ( 0 . 8 / 0 . 8 ) + P 4 ( 0 . 8 / 0 . 8 ) = 3 . 2 k i p s ( S e c . 4 . 3 . 4 . 1 ) Fo r c e - T r a n s f e r A r o u n d O p e n i n g s s h e a r w a l l ( S e c . 4 . 3 . 2 . 2 ) P1 4. 5 0 P2 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 33 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R # 2 , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 1 1 / 2 7 / 2 0 2 4 PL A N : 2 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 . 1 8 " | 4 * d * 1 . 4 = 1 " < 0 . 0 2 x 1 2 0 = 2 . 4 " 3. 5 0 6. 2 5 3. 0 0 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n HD U 2 HD U 2 Po s t S i z e 4x 4 4x 4 Up l i f t ( k i p s ) 2. 1 2. 8 Co m . ( k i p s ) 1. 7 2. 3 Ri g h t S i d e Ho l d D o w n HD U 2 HD U 2 Po s t S i z e 4x 4 4x 4 Te n s i o n ( k i p s ) 2. 1 2. 8 Co m . ( k i p s ) 1. 7 2. 3 An c h o r B o l t 5/ 8 " x 1 2 " [2 ] [2 ] sp a c e d e q u a l l y 4. 7 5 Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 10.00 ft LI N E 2 ( D i r e c t i o n : Y ) @ F I R S T F L O O R | W i n d : 2 4 7 7 l b s | S e i s m i c : 1 4 9 1 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 2 2 f t | T o t a l S h e a r W a l l L e n g t h = 9 . 7 5 f t | S h e a r D i a p h r a g m = 1 1 3 p l f | D e s i g n S h e a r W a l l = 2 8 5 p l f ( W i n d ) / 1 7 1 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 0 . 5 / 0 . 8 ) + P 2 ( 1 . 4 / 1 . 4 ) = 1 . 9 k i p s ( S e c . 4 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 0 . 8 / 1 . 1 ) + P 2 ( 1 . 9 / 1 . 9 ) = 2 . 7 k i p s ( S e c . 4 . 3 . 4 . 1 ) In d i v i d u a l f u l l - h e i g h t w a l l s e g m e n t s h e a r w a l l ( S e c . 4 . 3 . 2 . 1 ) P1 4. 5 0 P2 12 -87 3 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 34 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R # 2 , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 1 1 / 2 7 / 2 0 2 4 PL A N : 2 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 . 0 2 " | 4 * d * 1 . 4 = 0 . 0 9 " < 0 . 0 2 x 1 2 0 = 2 . 4 " 5. 5 0 12 . 0 0 3. 5 0 3. 7 5 6. 2 5 2. 0 0 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Up l i f t ( k i p s ) Co m . ( k i p s ) Ri g h t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) An c h o r B o l t 5/ 8 " x 1 2 " [2 ] sp a c e d e q u a l l y 5. 2 5 P1 2. 7 5 3. 2 5 5. 2 5 Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 10.00 ft LI N E A ( D i r e c t i o n : X ) @ F I R S T F L O O R | W i n d : 1 0 2 4 l b s | S e i s m i c : 1 3 0 7 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 4 9 . 5 f t | T o t a l S h e a r W a l l L e n g t h = 1 2 f t | S h e a r D i a p h r a g m = 3 8 p l f | D e s i g n S h e a r W a l l = 8 5 p l f ( W i n d ) / 1 0 9 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 2 . 6 / 2 . 6 ) = 2 . 6 k i p s ( S e c . 4 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 3 . 7 / 3 . 7 ) = 3 . 7 k i p s ( S e c . 4 . 3 . 4 . 1 ) In d i v i d u a l f u l l - h e i g h t w a l l s e g m e n t s h e a r w a l l ( S e c . 4 . 3 . 2 . 1 ) 20 7 -12 0 7 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 35 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Do ng E n g i n e e r i n g I n c . AD D I T I O N + A D U 51 2 1 W . R O B E R T S D R # 2 , S A N T A A N A , C A 9 2 7 0 4 Jo b # : 2 4 0 0 5 6 Da t e : 1 1 / 2 7 / 2 0 2 4 PL A N : 2 CO D E : C B C 2 0 2 2 Ma x p a n e l d e f l e c t i o n : = 0 . 0 2 " | 4 * d * 1 . 4 = 0 . 0 9 " < 0 . 0 2 x 1 2 0 = 2 . 4 " 17 . 7 5 7. 5 0 12 . 0 0 5. 7 5 OV E R T U R N A N A L Y S I S Le f t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Up l i f t ( k i p s ) Co m . ( k i p s ) Ri g h t S i d e Ho l d D o w n No U p l i f t Po s t S i z e Te n s i o n ( k i p s ) Co m . ( k i p s ) An c h o r B o l t 5/ 8 " x 1 2 " [2 ] sp a c e d e q u a l l y 3. 2 5 P1 Dr a g F o r c e : A: S i m p s o n M S T A 3 0 ( 1 8 8 0 L B ) - A l t o n e r o w ( 9 ) # 1 6 e a . s i d e o f s p l i c e Fr a m i n g C l i p s S p a c i n g S e e S h e a r W a l l S c h e d u l e 10.00 ft LI N E B ( D i r e c t i o n : X ) @ F I R S T F L O O R | W i n d : 1 0 2 4 l b s | S e i s m i c : 1 3 0 7 l b s | S h e a r P a n e l T y p e : A | ( þ = 1 ) To t a l L e n g t h = 4 9 f t | T o t a l S h e a r W a l l L e n g t h = 1 2 f t | S h e a r D i a p h r a g m = 3 8 p l f | D e s i g n S h e a r W a l l = 8 5 p l f ( W i n d ) / 1 0 9 p l f ( S e i s m i c ) Se i s m i c L o a d C o m b i n a t i o n : ( 1 . 0 + 0 . 1 4 S DS )D + H + F + 0 . 7 Q E ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : ( 0 . 6 - 0 . 1 4 S DS )D + H + 0 . 7 Q E ( T e n s i o n ) W i n d L o a d C o m b i n a t i o n : D + 0 . 7 5 L + 0 . 7 5 ( 0 . 6 W ) ( C o m p r e s s i o n ) | L o a d C o m b i n a t i o n U s e : 0 . 6 D + H + 0 . 6 W ( T e n s i o n ) Se i s m i c C a p a c i t y : P 1 ( 2 . 6 / 2 . 6 ) = 2 . 6 k i p s ( S e c . 4 . 3 . 4 . 1 ) W i n d C a p a c i t y : P 1 ( 3 . 7 / 3 . 7 ) = 3 . 7 k i p s ( S e c . 4 . 3 . 4 . 1 ) In d i v i d u a l f u l l - h e i g h t w a l l s e g m e n t s h e a r w a l l ( S e c . 4 . 3 . 2 . 1 ) 2. 7 5 11 9 1 -21 9 d = 8𝑣 ℎ3 𝐸 � � � � + 𝑣ℎ 10 0 0 � � 𝑎 + ℎ𝑏 ∆𝑎 36 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 Wind = Seismic = A B C D E F G H I J K L 2.75 2.75 Design Force = Wall Height = Wall Length = Window size = Bottom header = Top of window sill = Force Above Window (B & C)=1238 x (10 - 7 + 4 / 2) / 10 = 619 lbs Shear =619 / (10 - 7) = 206 plf Force Below Window (J & K)=1238 x (7 - 4 / 2) / 10 = 619 lbs Shear =619 / (7 - 4) = 206 plf Force on Left pier (E & G)=1238 x (2.75 + 4.5 / 2) / 10 = 619 lbs Shear =619 / 2.75 = 225 plf Force on Right pier (F & H)=1238 x (2.75 + 4.5 / 2) / 10 = 619 lbs Shear =619 / 2.75 = 225 plf Drag force at header =206 x 4.5 / 2 = 463.5 lbs Drag force at window sill =206 x 4.5 / 2 = 463.5 lbs Upper left sub panel shear (A)=(619 - 463.5) / 2.75 = 57 plf Upper right sub panel shear (D)=(619 - 463.5) / 2.75 = 57 plf Lower left sub panel shear (I)=(1238 - 1069) / 3 = 56 plf Lower right sub panel shear (L)=(1238 - 1069) / 3 = 56 plf Maximum sub panel shear =225 plf => USE TYPE A Maximum drag force =464 lbs => USE DRAG (1)CS16 Shear Wall With Opening: Shear Wall # 1 @ P1 & P2 3.00 ft 10 . 0 0 f t 4.50 1238 lbs 745 lbs 1238 lbs 10.00 ft 10.00 ft 4.5ft x 4ft 7.00 ft Shear wall design concept is chosen as Force-Transfer Around Openings (FTAO) (Sec. 4.3.2.2 ). 37 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 Wind = Seismic = A B C D E F G H I J K L 2.75 2.75 Design Force = Wall Height = Wall Length = Window size = Bottom header = Top of window sill = Force Above Window (B & C)=1238 x (10 - 7 + 4 / 2) / 10 = 619 lbs Shear =619 / (10 - 7) = 206 plf Force Below Window (J & K)=1238 x (7 - 4 / 2) / 10 = 619 lbs Shear =619 / (7 - 4) = 206 plf Force on Left pier (E & G)=1238 x (2.75 + 4.5 / 2) / 10 = 619 lbs Shear =619 / 2.75 = 225 plf Force on Right pier (F & H)=1238 x (2.75 + 4.5 / 2) / 10 = 619 lbs Shear =619 / 2.75 = 225 plf Drag force at header =206 x 4.5 / 2 = 463.5 lbs Drag force at window sill =206 x 4.5 / 2 = 463.5 lbs Upper left sub panel shear (A)=(619 - 463.5) / 2.75 = 57 plf Upper right sub panel shear (D)=(619 - 463.5) / 2.75 = 57 plf Lower left sub panel shear (I)=(1238 - 1069) / 3 = 56 plf Lower right sub panel shear (L)=(1238 - 1069) / 3 = 56 plf Maximum sub panel shear =225 plf => USE TYPE A Maximum drag force =464 lbs => USE DRAG (1)CS16 Shear Wall With Opening: Shear Wall # 1 @ P3 & P4 3.00 ft 10 . 0 0 f t 4.50 1238 lbs 745 lbs 1238 lbs 10.00 ft 10.00 ft 4.5ft x 4ft 7.00 ft Shear wall design concept is chosen as Force-Transfer Around Openings (FTAO) (Sec. 4.3.2.2 ). 38 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 Shear Wall (X-X Direction) Line Story Section Span Wind Seismic Added V (lb)H L v Type ###(ft)(plf)(plf)Wind Seismic (ft)(ft)(plf) A 1 1X 22 93 119 10 12 109 A B 1 1X 22 93 119 10 12 109 A SUMMARY SHEAR WALL V2 = Seismic*Span/2 + Added Vseismic Line shear V = Maximum(V1;V2) V1 = Wind*Span/2 + Added Vwind v(plf) = V/L Shear wall design concept is chosen as Individual full-height wall segment (Sec. 4.3.2.1 ) and Force-Transfer Around Openings (FTAO) (Sec. 4.3.2.2 ). For mix-type, chosen concept is determined by more critical design result. 39 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 Shear Wall (Y-Y Direction) Line Story Section Span Wind Seismic Added V (lb)H L v Type ###(ft)(plf)(plf)Wind Seismic (ft)(ft)(plf) 1 1 1Y 49 101 61 10 11 225 A 2 1 1Y 49 101 61 10 8.7 285 A Shear wall design concept is chosen as Individual full-height wall segment (Sec. 4.3.2.1 ) and Force-Transfer Around Openings (FTAO) (Sec. 4.3.2.2 ). For mix-type, chosen concept is determined by more critical design result. v(plf) = V/L Line shear V = Maximum(V1;V2) SUMMARY SHEAR WALL V1 = Wind*Span/2 + Added Vwind V2 = Seismic*Span/2 + Added Vseismic 40 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 Job #: 240056 Date : 11/27/2024 Plan : 2 BEAM : 1 - CLG @ LIVING ROOM Loads(Downward+) Beam Weight 26.3 plf from 0 ft to 25.25 ft Roof Primary: (15+20)(11) = (DL=165PLF; LLr=220PLF) form 0 to 25.25 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 4909/4909 0 2 4909/4909 0 USE 5 1/4" x 16" PSL Critcal Shear = 4908 LB @0' 1.5xV/(F'v x A)= 0.24 F'v = 362, A = 84 Critcal Moment = 30986 LB-FT @12.62' M/(F'b x S)= 0.45 F'b = 3625, S = 224 Critical Deflection for TL = -0.992 INCH @ 12.62 L/240 = 1.262" Critical Deflection for LL = -0.504 INCH @ 12.62 L/360 = 0.842" 1 2 Moment Shear Deflection 25.25' BEAM : C1 - C.J. 2X6#2 @ 16" O.C. TYP. (MAX L=15'-3") Loads(Downward+) Ceiling Joist: (4+10)(1.3) = (DL=5.3PLF; LLr=13.4PLF) form 0 to 15.25 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 143/143 0 2 143/143 0 USE 2 x 6 Critcal Shear = 142 LB @0' 1.5xV/(F'v x A)= 0.11 F'v = 225, A = 8.25 Critcal Moment = 543 LB-FT @7.62' M/(F'b x S)= 0.51 F'b = 1682, S = 7.56 Critical Deflection for TL = -0.684 INCH @ 7.63 L/240 = 0.762" Critical Deflection for LL = -0.488 INCH @ 7.63 L/360 = 0.508" 1 2 Moment Shear Deflection 15.25' 41 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR & #2, SANTA ANA, CA 92704 Job #: 240056 Date : 11/27/2024 Plan : 2 BEAM : R1 - R.R. 2X6#2 @ 16" O.C. TYP. (MAX L=12'-0") Loads(Downward+) Roof Rafter: (11+20)(1.3) = (DL=14.7PLF; LLr=26.7PLF) form 0 to 12 Reactions (D+Lr+L/Max. Load comb.) Bearing Down Up 1 248/248 0 2 248/248 0 USE 2 x 6 Critcal Shear = 248 LB @0' 1.5xV/(F'v x A)= 0.2 F'v = 225, A = 8.25 Critcal Moment = 744 LB-FT @6' M/(F'b x S)= 0.7 F'b = 1682, S = 7.56 Critical Deflection for TL = -0.58 INCH @ 6 L/240 = 0.6" Critical Deflection for LL = -0.374 INCH @ 6 L/360 = 0.4" 1 2 Moment Shear Deflection 12' 42 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 1500 psf Trib Trib Wall Height DL(psf)LL(psf)roof(ft)DL(psf)LL(psf)floor(ft)DL(psf)wall(ft) 15 20 12 10 10 Roof:(DL+LL)(Trib) =420 plf Floor:(DL+LL)(Trib) =0 plf Wall:DL (Height)=100 plf 520 plf 520 /(12"/12)=520 psf< 1500 psf P(allowable) P(allowable) = 4,500 # 18 in FOUNDATION - 1-STORY Allowable soil bearing value: Roof Floor use 12" wide cont. ftg w/ 2-#4 top & bott. 45𝑜 43 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Dong Engineering Inc. ADDITION + ADU 5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 Job#: 240056 Date: 11/27/2024 PLAN: 2 CODE: CBC 2022 BEAM NO. BM#1 Support 2 P =4,909 # Use 2' - 0"Square x 18" Deep Concrete Pad With 3-#4 Each way PAD SCHEDULE 44 of 44 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Tom Hatch CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall February 7, 2024 Also sent via email to: proselytus@gmail.com Lam Tran 5121 West Roberts Drive Santa Ana, CA 92704 Subject: Address Assignment for a Detached Accessory Dwelling Unit located at 5121 West Roberts Drive (APN: 188-062-27) in Santa Ana, CA Dear Lam, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a 1000-square-foot detached ADU located at 5121 West Roberts Drive (APN: 188-062-27). Notice is hereby given that the following assigned address shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address to be Activated/Posted New ADU) To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 664-2753 or by email at PRaj@santa-ana.org. Sincerely, Punkaj Raj Planning Technician Exhibit A – Address Plan FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 Address Letter for 5121 West Roberts Drive Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 LANDING W/HW/H EXHIBIT A: ADDRESS PLAN (E) GARAGE 5121 W. ROBERTS DRIVE (E) PRIMARY DWELLING (N) ADU 5121 W. ROBERTS DRIVE, UNIT 2 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025 FLOOD ZONE - 5121 W Roberts Dr & #23/19/2025