Loading...
HomeMy WebLinkAbout585 S Lyon St - PlanSOLAR INDIVIDUAL PERMIT PACKAGE TOLL BROTHERS - SOCAL OC SAN DIEGO 350 COMMERCE ST., SUITE 200 IRVINE, CA 92602 717 LYON PHASE 1 LOT 103 585 SOUTH LYON STREET TRACT/SUBDIVISION #: 19195 SANTA ANA, CALIFORNIA 92701 3.65 kW PHOTOVOLTAIC SYSTEM CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC)CH I FU N G L EU NGE LECT R IC A LE22659 Exp. 03-31-25RE GIST EREDP R O F ESSIONA L E NGI NEERS T A TE OF CA L I F O R NIADRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO 350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602 SOLAR ARCHITECTURAL DRAWINGS VICINITY MAP PROJECT LOCATION PVA-0 COVER SHEET PVA-1 SHEET INDEXGENERAL NOTES: SOLAR STRUCTURAL DRAWINGS PVS-1 MOUNTING DETAILS MOUNTING DETAILSPVS-2 MOUNTING DETAILSPVS-3 STRUCTURAL CALCULATIONSPVS-4 STRUCTURAL CALCULATIONSPVS-5 STRUCTURAL CALCULATIONS PVS-6 SOLAR ELECTRICAL DRAWINGS PVE-1 ELECTRICAL SINGLE LINE DIAGRAM & PVE-2 ELECTRICAL CALCULATIONS PVE-3 ELECTRICAL DETAILS AND PLACARD SPECIFICATIONS PVE-4 ELECTRICAL DATA & SPECIFICATIONS PVE-5 ELECTRICAL DATA & SPECIFICATIONS PVE-6 ELECTRICAL DATA & SPECIFICATIONS PVE-7 ELECTRICAL DATA & SPECIFICATIONS PVE-8 ELECTRICAL DATA & SPECIFICATIONS PVE-9 ELECTRICAL DATA & SPECIFICATIONS PVE-10 ELECTRICAL DATA & SPECIFICATIONS PVE-11 ELECTRICAL DATA & SPECIFICATIONS PVE-12 ELECTRICAL DATA & SPECIFICATIONS PVE-13 ELECTRICAL DATA & SPECIFICATIONS SHEET PVA-0 PHASE 1 LOT 103 SHEET SOLAR INDIVIDUAL PERMIT PACKAGEREV DESCRIPTION DATE CB **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** Bldg#: 101119878 Elec#: 20183266 585 S Lyon St-101119878 & 201832667/11/2024 TO ELECTRIC UTILITY GRID TO ELECTRIC UTILITY GRID UTILITY BI-DIRECTIONAL METER STACK/MAIN SWITCHBOARD (INSIDE ELECTRICAL ROOM) (E) SUB PANEL (INSIDE GARAGE) A/C CONDENSER AND PLATFORM ROOF HATCH ROOF WALKWAY PAD TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINTPLAN 4 UNIT 0103 N DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE PLAN ROOF TYPE ROOF PITCH ELEVATION ARRAY SQ. FT. MODULE QTY. MODULE TYPE SYSTEM SIZE STORY TYPE LOT & ARRAY INFORMATION MOUNTING & ATTACHMENT ORIENTATION LOCATION LOT NUMBER LAYOUT/SCHEME N/A 194 SQ. FT. 9 N/A 180° 3-STORY 3.65 kW FLAT FLAT ROOF 5-PLEX C Q.PEAK DUO BLK ML-G10+ (405)103 ON-RACK - INVISIMOUNT N/A PHASE NUMBER 1 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET SOLAR INDIVIDUAL PERMIT PACKAGEREV DESCRIPTION DATE CB PVA-1 FIRE ACCESS PATHWAY NOTES & LEGENDS ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BUILDING 1 LOT / UNIT 101 102 103 104 105 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET REV DESCRIPTION DATE CB PVS-1 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET REV DESCRIPTION DATE CB PVS-2 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET REV DESCRIPTION DATE CB PVS-3 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET REV DESCRIPTION DATE CB PVS-4 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET REV DESCRIPTION DATE CB PVS-5 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET REV DESCRIPTION DATE CB PVS-6 585 S Lyon St-101119878 & 201832667/11/2024 FIGURE A: SINGLE LINE DIAGRAM - 3.65 kWDC 1 2 H (NOT CENTER-FED)INCOMING SOURCE FEED MCB MCB UNIT MLO UTILITY BIDIRECTIONAL METER STACK/MAIN SWITCHBOARD (INSIDE ELECTRICAL ROOM) BUS RATING : BLDG. TYPE : GND TO EXISTING MSP GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER H (E) SUB-PANEL (MAIN LUG ONLY) 101 TO 105 200A, 2P 600A 5-PLEX 200A, 2P 600A, 120/240V, 1PH, 3W 20A, 2P 225A, 120/240V, 1PH, 3W TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION PV MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG NOTE : SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM PV BREAKER IS A MEANS OF DISCONNECT 2 A 1 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B DC AC SOLAR CABLE SUNPOWER PROVIDED ENGAGE CABLES 9 MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP SUNPOWER MONITORING PVS6 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL #22 PRODUCTION CURRENT TRANSFORMERS (100A) D C DD 1 #14 #14 1 #14 #14 NM CABLE OR EQ INSTALLED IN WALL CAVITY NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU INSTALLED IN WALL CAVITY 1/2" -- 3 C #6 D C 1 3 15A, 2P ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (NM-CABLE OR EQUIVALENT) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 14. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. 15. WHERE PV BREAKER IS TREATED AS A DISCONNECTING MEANS THE PV BREAKER MUST BE COMPATIBLE WITH LOCKING MEANS PER NEC 110.25 OR BY APPROVAL. MICROINVERTER QCELLS NORTH AMERICA MODULES CH I FU N G LEU NGE LECT R IC ALE22659 Exp. 03-31-25REGISTEREDPROFESSIONAL E NGI NEERS TATEOF CA L IF O RNIADRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONSHEET REV DESCRIPTION DATE CB PVE-1 585 S Lyon St-101119878 & 201832667/11/2024 Q-CABLE DATA SHEET 1/2 Q-CABLE DATA SHEET 2/2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-10 585 S Lyon St-101119878 & 201832667/11/2024 RAIL-MOUNTED JUNCTION BOX 1/2UNIVERSAL INVISIMOUNT INSTALLATION GUIDE 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-11 585 S Lyon St-101119878 & 201832667/11/2024 RAIL-MOUNTED JUNCTION BOX 2/2 QUICKMOUNT PV STANDOFF TECHNICAL DATASHEET 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-12 585 S Lyon St-101119878 & 201832667/11/2024 INVISIMOUNT DATA SHEET 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-13 585 S Lyon St-101119878 & 201832667/11/2024 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602CH I FU N G LEU NGE LECT R IC ALE22659 Exp. 03-31-25REGISTEREDPROFESSIONAL E NGI NEERS TATEOF CA L IF O RNIA880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET REV DESCRIPTION DATE CB PVE-2 ELECTRICAL CALCULATIONS585 S Lyon St-101119878 & 201832667/11/2024 1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 38" LETTER HEIGHT, WHITE ON RED BACKGROUND. 3. MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED. 4. MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY 10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL DC COMBINER AND JUNCTION BOXES. 5. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. SIGNAGE NOTES RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM x x AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE x x MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: 14.40 240 x x x x SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CONICAL FLASHING CYLINDRICAL FLASHINGCONDUIT ENTRY / EXIT DETAIL PULLBOX MOUNTING - FLAT ROOF FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602CH I FU N G LEU NGE LECT R IC ALE22659 Exp. 03-31-25REGISTEREDPROFESSIONAL E NGI NEERS TATEOF CA L IF O RNIA880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5N FIGURE 1: ELECTRICAL SIGNAGES/STICKERS FIGURE 3: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES ELECTRICAL DETAILS AND PLACARDDRIVEWAY SHEET REV DESCRIPTION DATE CB PVE-3 SUB PANEL PHOTOVOLTAICARRAY ON ROOF MAIN SERVICEPANEL POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION: 585 SOUTH LYON STREET 585 S Lyon St-101119878 & 201832667/11/2024 CURRENT TRANSFORMER SPECIFICATION SHEET CLASS A FIRE RATING LISTING PG 1/3 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-4 585 S Lyon St-101119878 & 201832667/11/2024 CLASS A FIRE RATING LISTING PG 2/3 CLASS A FIRE RATING LISTING PG 3/3 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-5 585 S Lyon St-101119878 & 201832667/11/2024 PV MODULE SPECIFICATION SHEET 1/2 PV MODULE SPECIFICATION SHEET 2/2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-6 585 S Lyon St-101119878 & 201832667/11/2024 PVS6 DATASHEET 1 PVS6 DATASHEET 2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-7 585 S Lyon St-101119878 & 201832667/11/2024 PVS6 INSTALLATION INSTRUCTIONS 2PVS6 INSTALLATION INSTRUCTIONS 1 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-8 585 S Lyon St-101119878 & 201832667/11/2024 ENPHASE DATA SHEET 1/2 ENPHASE DATA SHEET 2/2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C024242 RP-486701 2024-05-27 ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB PVE-9 585 S Lyon St-101119878 & 201832667/11/2024 6/18/24 City of Santa Ana 20 Civic Center Plaza Santa Ana, CA 92701 Re: Letter of Authorization to Process Plans and Permits on Behalf of Toll Brothers for 717 Lyon To Whom it May Concern: Please accept this letter as authorization for SunPower Corporation to install solar panels and pull related permits at the following addresses. 581 South Lyon Street 583 South Lyon Street 585 South Lyon Street 587 South Lyon Street 589 South Lyon Street 661 South Lyon Street 667 South Lyon Street 663 South Lyon Street 665 South Lyon Street 669 South Lyon Street 631 South Lyon Street 633 South Lyon Street 635 South Lyon Street 637 South Lyon Street 651 South Lyon Street 653 South Lyon Street 655 South Lyon Street 657 South Lyon Street 701 South Lyon Street 703 South Lyon Street 705 South Lyon Street 707 South Lyon Street 597 South Lyon Street 595 South Lyon Street 593 South Lyon Street 591 South Lyon Street 693 South Lyon Street 691 South Lyon Street 601 South Lyon Street 603 South Lyon Street 605 South Lyon Street 607 South Lyon Street 609 South Lyon Street 681 South Lyon Street 683 South Lyon Street 685 South Lyon Street 687 South Lyon Street 689 South Lyon Stre et 617 South Lyon Street 615 South Lyon Street 613 South Lyon Street 611 South Lyon Street 677 South Lyon Street 675 South Lyon Street 673 South Lyon Street 671 South Lyon Street 621 South Lyon Street 623 South Lyon Street 625 South Lyon Street 627 South Lyon Street 629 South Lyon Street DocuSign Envelope ID: 73E61C96-D098-46A0-81F4-A2CAD99D9940 585 S Lyon St-101119878 & 201832667/11/2024 Should you have any questions, please do not hesitate to contact me at hwinterhalter@tollbrothers.com or at (949) 444-9526. Sincerely, Henry Winterhalter Project Manager Toll Brothers DocuSign Envelope ID: 73E61C96-D098-46A0-81F4-A2CAD99D9940 06-18-2024 585 S Lyon St-101119878 & 201832667/11/2024 Certificate Of Completion Envelope Id: 73E61C96D09846A081F4A2CAD99D9940 Status: Completed Subject: Complete with Docusign: 717 Lyon Solar_LOA.pdf Source Envelope: Document Pages: 2 Signatures: 1 Envelope Originator: Certificate Pages: 1 Initials: 0 Henry Winterhalter AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-05:00) Eastern Time (US & Canada) 1140 Virginia Dr Fort Washington, PA 19034 hwinterhalter@tollbrothers.com IP Address: 70.184.69.163 Record Tracking Status: Original 6/18/2024 1:57:19 PM Holder: Henry Winterhalter hwinterhalter@tollbrothers.com Location: DocuSign Signer Events Signature Timestamp Henry Winterhalter hwinterhalter@tollbrothers.com Project Manager Security Level: Email, Account Authentication (None)Signature Adoption: Pre-selected Style Using IP Address: 4.36.253.18 Sent: 6/18/2024 1:57:44 PM Viewed: 6/18/2024 1:57:50 PM Signed: 6/18/2024 1:57:53 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 6/18/2024 1:57:44 PM Certified Delivered Security Checked 6/18/2024 1:57:50 PM Signing Complete Security Checked 6/18/2024 1:57:53 PM Completed Security Checked 6/18/2024 1:57:53 PM Payment Events Status Timestamps 585 S Lyon St-101119878 & 201832667/11/2024 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 585 S Lyon St-101119878 & 201832667/11/2024 Expedited Permit Process for PV Systems — Micro-Inverter 2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 585 S Lyon St-101119878 & 201832667/11/2024 Expedited Permit Process for PV Systems 3 Micro-Inverter Site Plan585 S LyonSt-101119878 &201832667/11/2024 Expedited Permit Process for PV Systems 4 Micro-Inverter Electrical DiagramContractor Name, Address and Phone:One-Line Standard Electrical Diagramfor Micro-Inverter PV SystemsSite Name: Site Address: System AC Size: SIZEFSCM NODWG NOREVE1.1aSCALENTSDate: SHEETDrawn By:Checked By:DESCRIPTION OR CONDUCTOR TYPEUSE-2 or PV WIRE GEC EGC X ALL THAT APPLYEXTERIOR CABLE LISTED W/ INV.THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLYNO DC GEC IF 690.35 SYSTEMTHWN-2 or XHHW-2 or RHW-2GEC EGC X ALL THAT APPLYTAG12345CONDUIT AND CONDUCTOR SCHEDULECOND.GAUGEMFGMFGNUMBER OFCONDUCTORSMFG CableMFG CableCONDUITTYPEN/AN/AN/ASAME SAMECONDUITSIZEN/AN/AN/ASAMESAMEDESCRIPTION PV DC or AC MODULEDC/AC INVERTER (MICRO)J-BOX (IF USED)PV ARRAYAC COMB. PANEL (IF USED)GEN METER (IF USED)AC DISCONNECT (IF USED)SERVICE PANELTAG12345678PART NUMBERNOTESFOR UNUSED MODULESPUT "N/A” in BLANK ABOVE11323EQUIPMENT SCHEDULE2_____ MICRO-INVERTERS IN BRANCH-CIRCUITMOD____DCACMOD____DCACMOD____DCACMOD____DCACMOD____DCACMOD____DCACJ-BOX4AC DISCOMBUILDINGGROUNDING ELECTRODEGMUTILITY SERVICEMAIN SERVICE PANELMAINOCPDINVERTEROCPD678545GSEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDINGAC COMBINER PANELG____ MICRO-INVERTERS IN BRANCH-CIRCUIT585 S LyonSt-101119878 &201832667/11/2024 Expedited Permit Process for PV Systems 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV SystemsSite Name: Site Address: System AC Size: SIZEFSCM NODWG NOREVE1.2aSCALENTSDate: SHEETDrawn By:Checked By:MAX POWER-POINT CURRENT (IMP)MAX POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)MAX SERIES FUSE (OCPD)MAXIMUM POWER (PMAX)MAX VOLTAGE (TYP 600VDC)VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITSMODULE MAKEMODULE MODELPV MODULE RATINGS @ STC (Guide Section 5)MAX DC VOLT RATINGMAX POWER @ 40oCNOMINAL AC VOLTAGEMAX AC CURRENTMAX OCPD RATINGINVERTER MAKEINVERTER MODELINVERTER RATINGS (Guide Section 4)1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9)5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NONOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE.NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E):OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX)NOTES FOR ALL DRAWINGS:SIGNS–SEE GUIDE SECTION 7SIGN FOR DC DISCONNECTSIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED)No sign necessary since 690.51 marking on PV module covers needed informationAC OUTPUT CURRENTNOMINAL AC VOLTAGESOLAR PV SYSTEMAC POINT OF CONNECTIONTHIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)Notes for Micro-Inverter Electrical Diagram585 S LyonSt-101119878 &201832667/11/2024 1414 Harbour Way S. Suite 1901, Richmond, CA 94804 March 30, 2024 RE: Authorization to Submit and Execute Permits on Behalf of SunPower Corporation, Systems California Contractor License Number 890895 To whom it may concern: The undersigned duly appointed and authorized Officer of SunPower Corporation, Systems (the “Company”), hereby that Eddielyn Abano, Permit Coordinator of SunPower Corporation, Systems is authorized, upon receipt of a work order from SunPower Corporation, Systems, to receive and pick up approved plans + permits at all cities and counties located within the State of California on behalf of the Company. This Authorization remains in effect until revoked. Thank you, Brian Risi Responsible Managing Employee, C-10 SunPower Corporation, Systems 1414 Harbour Way S., Ste. 1901 Richmond, CA 94804 Brian.risi@sunpowercorp.com CA License #890895 585 S Lyon St-101119878 & 201832667/11/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.  2.  3.  4.  5.  6.  7.  8.  9.  10.  Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed witha space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? Will the PV system be installed without using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 585 S Lyon St-101119878 & 201832667/11/2024 BUILDING AND SAFETY DEPARTMENT City of  RE: PLAN CHECK RESPONSE Project Name: Project Address: Project Description: Rooftop Photovoltaic System Individual Permit Package for 717 Lyon ‐ Bldg. 1 ‐ Lot 103 This is in response to the plan check comments dated 6/17/2024 for the project noted above. Should you have any additional questions, please feel free to contact me. Sincerely, _____________________________ Eddielyn Abaño / Permit Coordinator SunPower Corporation / 408‐514‐4114 eddielyn.abano@sunpowercorp.com 717 Lyon ‐ Bldg. 1 ‐ Lot 103 585 South Lyon Street, Santa Ana, CA 92701 6/18/2024 Santa Ana Plan Check Number:  Structural sheets are already stamped by Engineer. Structural Calculations (if applicable) Structural pages stamped by Licensed Structural Engineer ‐ refer to #10 on the Residential Solar  Checklist for pages requiring a structural engineer stamp Comment 4 Comment No.Response 1 Solar Permit Application including project valuation ‐ missing valuation Valuation has been added to application. Signed Homeowner authorization letter to install solar panels (if DocuSign, must provide  confirmation page) ‐ Need a letter from the developer stating they are allowing your company  to install solar panels (it can be a letter which includes all addresses or individually) 2 3 Electrical solar ABCs forms (Must be completed electronically) ‐ On page 2, Step 1 #2 ‐ is  marked no, if the answer is correct plan check is required Signed Homeowner Letter of Authorization has been uploaded. The correct answer is Yes, ABC form has been updated and uploaded. Already part of the plan. Pages PVS-4 to PVS-6. 585 S Lyon St-101119878 & 201832667/11/2024