HomeMy WebLinkAbout585 S Lyon St - PlanSOLAR INDIVIDUAL PERMIT PACKAGE
TOLL BROTHERS - SOCAL OC SAN DIEGO
350 COMMERCE ST., SUITE 200
IRVINE, CA 92602
717 LYON
PHASE 1 LOT 103
585 SOUTH LYON STREET
TRACT/SUBDIVISION #: 19195
SANTA ANA, CALIFORNIA 92701
3.65 kW PHOTOVOLTAIC SYSTEM
CODE INFORMATION
APPLICABLE CODES, LAWS AND REGULATIONS
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA RESIDENTIAL CODE (CRC)
2022 CALIFORNIA FIRE CODE (CFC)
2022 CALIFORNIA ELECTRICAL CODE (CEC)
2022 CALIFORNIA MECHANICAL CODE (CMC)
2022 CALIFORNIA PLUMBING CODE (CPC)CH I FU N G L EU
NGE
LECT R IC A LE22659
Exp. 03-31-25RE GIST EREDP R O F ESSIONA
L
E
NGI
NEERS
T
A
TE OF CA L I F O R NIADRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO 350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602 SOLAR ARCHITECTURAL DRAWINGS
VICINITY MAP
PROJECT LOCATION
PVA-0 COVER SHEET
PVA-1
SHEET INDEXGENERAL NOTES:
SOLAR STRUCTURAL DRAWINGS
PVS-1 MOUNTING DETAILS
MOUNTING DETAILSPVS-2
MOUNTING DETAILSPVS-3
STRUCTURAL CALCULATIONSPVS-4
STRUCTURAL CALCULATIONSPVS-5
STRUCTURAL CALCULATIONS PVS-6
SOLAR ELECTRICAL DRAWINGS
PVE-1 ELECTRICAL SINGLE LINE DIAGRAM &
PVE-2 ELECTRICAL CALCULATIONS
PVE-3 ELECTRICAL DETAILS AND PLACARD
SPECIFICATIONS
PVE-4 ELECTRICAL DATA & SPECIFICATIONS
PVE-5 ELECTRICAL DATA & SPECIFICATIONS
PVE-6 ELECTRICAL DATA & SPECIFICATIONS
PVE-7 ELECTRICAL DATA & SPECIFICATIONS
PVE-8 ELECTRICAL DATA & SPECIFICATIONS
PVE-9 ELECTRICAL DATA & SPECIFICATIONS
PVE-10 ELECTRICAL DATA & SPECIFICATIONS
PVE-11 ELECTRICAL DATA & SPECIFICATIONS
PVE-12 ELECTRICAL DATA & SPECIFICATIONS
PVE-13 ELECTRICAL DATA & SPECIFICATIONS SHEET
PVA-0
PHASE 1 LOT 103
SHEET SOLAR INDIVIDUAL PERMIT PACKAGEREV DESCRIPTION DATE CB
**The scope of the plans is for the installation of the solar photovoltaic system only and the
approval is subject to compliance with all applicable city and state codes and regulations
regarding construction. The approval of the plans does not constitute any certification of the
accuracy, completeness, or building permit status of the existing buildings and structures as
shown.***
Bldg#: 101119878
Elec#: 20183266
585 S Lyon
St-101119878 &
201832667/11/2024
TO ELECTRIC
UTILITY GRID
TO ELECTRIC
UTILITY GRID
UTILITY BI-DIRECTIONAL METER
STACK/MAIN SWITCHBOARD
(INSIDE ELECTRICAL ROOM)
(E) SUB PANEL
(INSIDE GARAGE)
A/C CONDENSER AND
PLATFORM
ROOF HATCH
ROOF WALKWAY PAD
TRANSITION BOX (TYP.)
ROOF ACCESS
POINT
ROOF ACCESS
POINTPLAN 4
UNIT 0103
N
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE
PLAN
ROOF TYPE
ROOF PITCH
ELEVATION
ARRAY SQ. FT.
MODULE QTY.
MODULE TYPE
SYSTEM SIZE
STORY TYPE
LOT & ARRAY INFORMATION
MOUNTING &
ATTACHMENT
ORIENTATION
LOCATION
LOT NUMBER
LAYOUT/SCHEME
N/A
194 SQ. FT.
9
N/A
180°
3-STORY
3.65 kW
FLAT
FLAT ROOF
5-PLEX C
Q.PEAK DUO BLK ML-G10+ (405)103
ON-RACK - INVISIMOUNT
N/A
PHASE NUMBER 1
717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET SOLAR INDIVIDUAL PERMIT PACKAGEREV DESCRIPTION DATE CB
PVA-1
FIRE ACCESS PATHWAY
NOTES & LEGENDS
ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR
INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR
BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT.
BUILDING 1
LOT / UNIT 101 102 103 104 105
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET
REV DESCRIPTION DATE CB
PVS-1
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET
REV DESCRIPTION DATE CB
PVS-2
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET
REV DESCRIPTION DATE CB
PVS-3
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET
REV DESCRIPTION DATE CB
PVS-4
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET
REV DESCRIPTION DATE CB
PVS-5
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602SHEET
REV DESCRIPTION DATE CB
PVS-6
585 S Lyon
St-101119878 &
201832667/11/2024
FIGURE A: SINGLE LINE DIAGRAM - 3.65 kWDC
1
2
H
(NOT CENTER-FED)INCOMING SOURCE FEED
MCB MCB
UNIT
MLO
UTILITY
BIDIRECTIONAL METER
STACK/MAIN SWITCHBOARD
(INSIDE ELECTRICAL ROOM)
BUS RATING :
BLDG. TYPE :
GND
TO EXISTING
MSP GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
H
(E) SUB-PANEL
(MAIN LUG ONLY)
101 TO 105
200A, 2P
600A
5-PLEX
200A, 2P
600A, 120/240V, 1PH, 3W
20A, 2P
225A, 120/240V, 1PH, 3W
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
PV MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
NOTE :
SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN
THE HOUSE FOR CONSTRUCTION FEASIBILITY.
BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
PV BREAKER IS A
MEANS OF DISCONNECT
2
A
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
B
DC
AC
SOLAR CABLE
SUNPOWER PROVIDED ENGAGE
CABLES
9 MODULESBRANCH CIRCUIT #1
Q.PEAK DUO BLK ML-G10+ (405)
#10
#10
IQ7HS-66-M-US (240)
ATTIC
ROOFTOP
SUNPOWER
MONITORING
PVS6
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
#22
PRODUCTION CURRENT
TRANSFORMERS (100A)
D
C
DD
1
#14
#14 1
#14
#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
INSTALLED IN WALL
CAVITY
1/2"
--
3
C
#6
D
C 1
3
15A, 2P
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (NM-CABLE OR EQUIVALENT) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC
REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE.
13. AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED.
14. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED.
15. WHERE PV BREAKER IS TREATED AS A DISCONNECTING MEANS THE PV BREAKER MUST BE COMPATIBLE WITH LOCKING MEANS PER NEC 110.25 OR BY
APPROVAL.
MICROINVERTER
QCELLS NORTH AMERICA MODULES
CH I FU N G LEU
NGE
LECT R IC ALE22659
Exp. 03-31-25REGISTEREDPROFESSIONAL
E
NGI
NEERS
TATEOF CA L IF O RNIADRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONSHEET
REV DESCRIPTION DATE CB
PVE-1
585 S Lyon
St-101119878 &
201832667/11/2024
Q-CABLE DATA SHEET 1/2 Q-CABLE DATA SHEET 2/2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-10
585 S Lyon
St-101119878 &
201832667/11/2024
RAIL-MOUNTED JUNCTION BOX 1/2UNIVERSAL INVISIMOUNT INSTALLATION GUIDE 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-11
585 S Lyon
St-101119878 &
201832667/11/2024
RAIL-MOUNTED JUNCTION BOX 2/2 QUICKMOUNT PV STANDOFF TECHNICAL DATASHEET 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-12
585 S Lyon
St-101119878 &
201832667/11/2024
INVISIMOUNT DATA SHEET 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-13
585 S Lyon
St-101119878 &
201832667/11/2024
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602CH I FU N G LEU
NGE
LECT R IC ALE22659
Exp. 03-31-25REGISTEREDPROFESSIONAL
E
NGI
NEERS
TATEOF CA L IF O RNIA880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET
REV DESCRIPTION DATE CB
PVE-2 ELECTRICAL CALCULATIONS585 S Lyon
St-101119878 &
201832667/11/2024
1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT
AND SUITABLE FOR THE ENVIRONMENT.
2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM
38" LETTER HEIGHT,
WHITE ON RED BACKGROUND.
3. MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO MAIN
SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION
WHERE THE LEVER IS OPERATED.
4. MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS,
ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE
SERVICE TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY 10', AT
TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL DC COMBINER
AND JUNCTION BOXES.
5. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE.
SIGNAGE NOTES
RAPID SHUTDOWN SWITCH FOR
SOLAR PV SYSTEM
x
x
AMPS
VOLTS
PHOTOVOLTAIC POINT OF
INTERCONNECTION
WARNING: ELECTIC SHOCK HAZARD. DO NOT
TOUCH TERMINALS. TERMINALS ON BOTH THE
LINE AND LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION. FOR SERVICE
DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER
PV POWER SOURCE
x
x
MAXIMUM RATED AC OUTPUT CURRENT:
MAXIMUM OPERATING AC VOLTAGE:
14.40
240
x
x
x
x
SOLAR PV SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUTDOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD
IN THE ARRAY
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVERCURRENT DEVICE
CONICAL FLASHING
CYLINDRICAL FLASHINGCONDUIT ENTRY / EXIT DETAIL
PULLBOX MOUNTING - FLAT ROOF
FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602CH I FU N G LEU
NGE
LECT R IC ALE22659
Exp. 03-31-25REGISTEREDPROFESSIONAL
E
NGI
NEERS
TATEOF CA L IF O RNIA880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5N
FIGURE 1: ELECTRICAL SIGNAGES/STICKERS FIGURE 3: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES
ELECTRICAL DETAILS AND PLACARDDRIVEWAY
SHEET
REV DESCRIPTION DATE CB
PVE-3
SUB PANEL
PHOTOVOLTAICARRAY ON ROOF
MAIN SERVICEPANEL
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
CAUTION:
585 SOUTH LYON STREET
585 S Lyon
St-101119878 &
201832667/11/2024
CURRENT TRANSFORMER SPECIFICATION SHEET CLASS A FIRE RATING LISTING PG 1/3 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-4
585 S Lyon
St-101119878 &
201832667/11/2024
CLASS A FIRE RATING LISTING PG 2/3 CLASS A FIRE RATING LISTING PG 3/3 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-5
585 S Lyon
St-101119878 &
201832667/11/2024
PV MODULE SPECIFICATION SHEET 1/2 PV MODULE SPECIFICATION SHEET 2/2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-6
585 S Lyon
St-101119878 &
201832667/11/2024
PVS6 DATASHEET 1 PVS6 DATASHEET 2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-7
585 S Lyon
St-101119878 &
201832667/11/2024
PVS6 INSTALLATION INSTRUCTIONS 2PVS6 INSTALLATION INSTRUCTIONS 1 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-8
585 S Lyon
St-101119878 &
201832667/11/2024
ENPHASE DATA SHEET 1/2 ENPHASE DATA SHEET 2/2 717 LYONTRACT/SUBDIVISION #: 19195TOLL BROTHERS - SOCAL OC SAN DIEGO350 COMMERCE ST., SUITE 200 585 SOUTH LYON STREETSANTA ANA, CALIFORNIA 92701IRVINE, CA 92602DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C024242
RP-486701
2024-05-27
ADRIELLE LATADE880 H A R B O U R W A Y S O U T HS U I T E 6 0 0C O R P O R A T I O N , S Y S T E M STHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.®R I C H M O N D , C A 9 4 8 0 4( 5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5SHEET ELECTRICAL DATA & SPECIFICATIONSREV DESCRIPTION DATE CB
PVE-9
585 S Lyon
St-101119878 &
201832667/11/2024
6/18/24
City of Santa Ana
20 Civic Center Plaza
Santa Ana, CA 92701
Re: Letter of Authorization to Process Plans and Permits on Behalf of
Toll Brothers for 717 Lyon
To Whom it May Concern:
Please accept this letter as authorization for SunPower Corporation to install solar panels and pull related
permits at the following addresses.
581 South Lyon Street
583 South Lyon Street
585 South Lyon Street
587 South Lyon Street
589 South Lyon Street
661 South Lyon Street
667 South Lyon Street
663 South Lyon Street
665 South Lyon Street
669 South Lyon Street
631 South Lyon Street
633 South Lyon Street
635 South Lyon Street
637 South Lyon Street
651 South Lyon Street
653 South Lyon Street
655 South Lyon Street
657 South Lyon Street
701 South Lyon Street
703 South Lyon Street
705 South Lyon Street
707 South Lyon Street
597 South Lyon Street
595 South Lyon Street
593 South Lyon Street
591 South Lyon Street
693 South Lyon Street
691 South Lyon Street
601 South Lyon Street
603 South Lyon Street
605 South Lyon Street
607 South Lyon Street
609 South Lyon Street
681 South Lyon Street
683 South Lyon Street
685 South Lyon Street
687 South Lyon Street
689 South Lyon Stre et
617 South Lyon Street
615 South Lyon Street
613 South Lyon Street
611 South Lyon Street
677 South Lyon Street
675 South Lyon Street
673 South Lyon Street
671 South Lyon Street
621 South Lyon Street
623 South Lyon Street
625 South Lyon Street
627 South Lyon Street
629 South Lyon Street
DocuSign Envelope ID: 73E61C96-D098-46A0-81F4-A2CAD99D9940
585 S Lyon
St-101119878 &
201832667/11/2024
Should you have any questions, please do not hesitate to contact me at
hwinterhalter@tollbrothers.com or at (949) 444-9526.
Sincerely,
Henry Winterhalter
Project Manager
Toll Brothers
DocuSign Envelope ID: 73E61C96-D098-46A0-81F4-A2CAD99D9940
06-18-2024
585 S Lyon
St-101119878 &
201832667/11/2024
Certificate Of Completion
Envelope Id: 73E61C96D09846A081F4A2CAD99D9940 Status: Completed
Subject: Complete with Docusign: 717 Lyon Solar_LOA.pdf
Source Envelope:
Document Pages: 2 Signatures: 1 Envelope Originator:
Certificate Pages: 1 Initials: 0 Henry Winterhalter
AutoNav: Enabled
EnvelopeId Stamping: Enabled
Time Zone: (UTC-05:00) Eastern Time (US & Canada)
1140 Virginia Dr
Fort Washington, PA 19034
hwinterhalter@tollbrothers.com
IP Address: 70.184.69.163
Record Tracking
Status: Original
6/18/2024 1:57:19 PM
Holder: Henry Winterhalter
hwinterhalter@tollbrothers.com
Location: DocuSign
Signer Events Signature Timestamp
Henry Winterhalter
hwinterhalter@tollbrothers.com
Project Manager
Security Level: Email, Account Authentication
(None)Signature Adoption: Pre-selected Style
Using IP Address: 4.36.253.18
Sent: 6/18/2024 1:57:44 PM
Viewed: 6/18/2024 1:57:50 PM
Signed: 6/18/2024 1:57:53 PM
Electronic Record and Signature Disclosure:
Not Offered via DocuSign
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 6/18/2024 1:57:44 PM
Certified Delivered Security Checked 6/18/2024 1:57:50 PM
Signing Complete Security Checked 6/18/2024 1:57:53 PM
Completed Security Checked 6/18/2024 1:57:53 PM
Payment Events Status Timestamps
585 S Lyon
St-101119878 &
201832667/11/2024
Expedited Permit Process for PV Systems - Micro-Inverter1
Expedited Permit Process for PV Systems
Micro-Inverter
The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro-
cess provides a means to differentiate systems that can be permitted quickly and easily
due to their similarity with the majority of small-scale PV systems. Those systems with
unique characteristics may be handled with small additions to this Expedited Permit
Process or may require much more information, depending on the uniqueness of the
installation.
The following pages contain forms for the Micro-Inverter to use with the Expedited Per-
mit Process. The Standard String, AC Module, and Supply-Side Connection forms
are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic-
tions that have adopted the Expedited Permit Process for PV Systems, these forms can
be filled out electronically and submitted in either printed form and via email. An elec-
tronic format is used so that the supplied information is standardized and legible for the
local jurisdiction.
585 S Lyon
St-101119878 &
201832667/11/2024
Expedited Permit Process for PV Systems — Micro-Inverter 2
Expedited Permit Process for Small-Scale PV Systems
Micro-Inverter
The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations
are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential
systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been
suggested to provide as a path to permit approval.
Required Information for Permit:
1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it
should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings
with a 3’ perimeter space at ridge and sides may not need separate fire service review.
2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects,
required signs, and ac connection to building (see supplied standard electrical diagram).
3. Specification sheets and installation manuals (if available) for all manufactured components including, but not
limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system.
Step 1: Structural Review of PV Array Mounting System
Is the array to be mounted on a defined, permitted roof structure? l Yes l No
If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1.
Roof Information:
1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________
____________________________________________________________________________________________________
If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…).
2. Does the roof have a single roof covering? l Yes l No
If No, submit completed worksheet for roof structure WKS1.
3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________
Mounting System Information:
1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap
beneath the module frames? l Yes l No
If No, provide details of structural attachment certified by a design professional.
2. For manufactured mounting systems, fill out information on the mounting system below:
a. Mounting System Manufacturer ___________Product Name and Model#________________________________
b. Total Weight of PV Modules and Rails ___________lbs
c. Total Number of Attachment Points____________
d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1)
e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for
maximum spacing allowed based on maximum design wind speed)
f. Total Surface Area of PV Modules (square feet)_________________ ft2
g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2
If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1.
Step 2: Electrical Review of PV System (Calculations for Electrical Diagram)
In order for a PV system to be considered for an expedited permit process, the following must apply:
1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems.
2. The PV array is composed of 4 series strings or less per inverter.
3. The total inverter capacity has a continuous ac power output 13,440 Watts or less
4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)).
5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV
system. Interactive PDF diagrams are available at www.solarabcs.org/permitting.
Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant
understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively
communicate, provide an alternative diagram with appropriate detail.
585 S Lyon
St-101119878 &
201832667/11/2024
Expedited Permit Process for PV Systems 3 Micro-Inverter Site Plan585 S LyonSt-101119878 &201832667/11/2024
Expedited Permit Process for PV Systems 4 Micro-Inverter Electrical DiagramContractor Name, Address and Phone:One-Line Standard Electrical Diagramfor Micro-Inverter PV SystemsSite Name: Site Address: System AC Size: SIZEFSCM NODWG NOREVE1.1aSCALENTSDate: SHEETDrawn By:Checked By:DESCRIPTION OR CONDUCTOR TYPEUSE-2 or PV WIRE GEC EGC X ALL THAT APPLYEXTERIOR CABLE LISTED W/ INV.THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLYNO DC GEC IF 690.35 SYSTEMTHWN-2 or XHHW-2 or RHW-2GEC EGC X ALL THAT APPLYTAG12345CONDUIT AND CONDUCTOR SCHEDULECOND.GAUGEMFGMFGNUMBER OFCONDUCTORSMFG CableMFG CableCONDUITTYPEN/AN/AN/ASAME SAMECONDUITSIZEN/AN/AN/ASAMESAMEDESCRIPTION PV DC or AC MODULEDC/AC INVERTER (MICRO)J-BOX (IF USED)PV ARRAYAC COMB. PANEL (IF USED)GEN METER (IF USED)AC DISCONNECT (IF USED)SERVICE PANELTAG12345678PART NUMBERNOTESFOR UNUSED MODULESPUT "N/A” in BLANK ABOVE11323EQUIPMENT SCHEDULE2_____ MICRO-INVERTERS IN BRANCH-CIRCUITMOD____DCACMOD____DCACMOD____DCACMOD____DCACMOD____DCACMOD____DCACJ-BOX4AC DISCOMBUILDINGGROUNDING ELECTRODEGMUTILITY SERVICEMAIN SERVICE PANELMAINOCPDINVERTEROCPD678545GSEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDINGAC COMBINER PANELG____ MICRO-INVERTERS IN BRANCH-CIRCUIT585 S LyonSt-101119878 &201832667/11/2024
Expedited Permit Process for PV Systems 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV SystemsSite Name: Site Address: System AC Size: SIZEFSCM NODWG NOREVE1.2aSCALENTSDate: SHEETDrawn By:Checked By:MAX POWER-POINT CURRENT (IMP)MAX POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)MAX SERIES FUSE (OCPD)MAXIMUM POWER (PMAX)MAX VOLTAGE (TYP 600VDC)VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITSMODULE MAKEMODULE MODELPV MODULE RATINGS @ STC (Guide Section 5)MAX DC VOLT RATINGMAX POWER @ 40oCNOMINAL AC VOLTAGEMAX AC CURRENTMAX OCPD RATINGINVERTER MAKEINVERTER MODELINVERTER RATINGS (Guide Section 4)1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9)5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NONOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE.NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E):OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX)NOTES FOR ALL DRAWINGS:SIGNS–SEE GUIDE SECTION 7SIGN FOR DC DISCONNECTSIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED)No sign necessary since 690.51 marking on PV module covers needed informationAC OUTPUT CURRENTNOMINAL AC VOLTAGESOLAR PV SYSTEMAC POINT OF CONNECTIONTHIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)Notes for Micro-Inverter Electrical Diagram585 S LyonSt-101119878 &201832667/11/2024
1414 Harbour Way S. Suite 1901, Richmond, CA 94804
March 30, 2024
RE: Authorization to Submit and Execute Permits on Behalf of
SunPower Corporation, Systems
California Contractor License Number 890895
To whom it may concern:
The undersigned duly appointed and authorized Officer of SunPower Corporation, Systems (the
“Company”), hereby that Eddielyn Abano, Permit Coordinator of SunPower Corporation, Systems
is authorized, upon receipt of a work order from SunPower Corporation, Systems, to receive and
pick up approved plans + permits at all cities and counties located within the State of California
on behalf of the Company. This Authorization remains in effect until revoked.
Thank you,
Brian Risi
Responsible Managing Employee, C-10
SunPower Corporation, Systems
1414 Harbour Way S., Ste. 1901
Richmond, CA 94804
Brian.risi@sunpowercorp.com
CA License #890895
585 S Lyon
St-101119878 &
201832667/11/2024
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
Will the PV system be installed on a roof having only one roofing layer with no
overlays?
Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
Will the PV system weigh maximum 4 pounds per square feet or less?
Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be installed witha space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
Will the PV system be installed without using any ballast system or counter-weight
system?
Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
585 S Lyon
St-101119878 &
201832667/11/2024
BUILDING AND SAFETY DEPARTMENT
City of
RE: PLAN CHECK RESPONSE
Project Name:
Project Address:
Project Description: Rooftop Photovoltaic System Individual Permit Package for 717 Lyon ‐ Bldg. 1 ‐ Lot 103
This is in response to the plan check comments dated 6/17/2024 for the project noted above.
Should you have any additional questions, please feel free to contact me.
Sincerely,
_____________________________
Eddielyn Abaño / Permit Coordinator
SunPower Corporation / 408‐514‐4114
eddielyn.abano@sunpowercorp.com
717 Lyon ‐ Bldg. 1 ‐ Lot 103
585 South Lyon Street, Santa Ana, CA 92701
6/18/2024
Santa Ana
Plan Check Number:
Structural sheets are already stamped by Engineer.
Structural Calculations (if applicable)
Structural pages stamped by Licensed Structural Engineer ‐ refer to #10 on the Residential Solar
Checklist for pages requiring a structural engineer stamp
Comment
4
Comment No.Response
1 Solar Permit Application including project valuation ‐ missing valuation Valuation has been added to application.
Signed Homeowner authorization letter to install solar panels (if DocuSign, must provide
confirmation page) ‐ Need a letter from the developer stating they are allowing your company
to install solar panels (it can be a letter which includes all addresses or individually)
2
3
Electrical solar ABCs forms (Must be completed electronically) ‐ On page 2, Step 1 #2 ‐ is
marked no, if the answer is correct plan check is required
Signed Homeowner Letter of Authorization has been uploaded.
The correct answer is Yes, ABC form has been updated
and uploaded.
Already part of the plan. Pages PVS-4 to PVS-6.
585 S Lyon
St-101119878 &
201832667/11/2024