HomeMy WebLinkAbout1000 W MacArthur Blvd Unit# 72 - PlanBMPS NPDES NOTES PROJECT SUMMARY VICINITY MAP 1. ANY OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND /OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING WITH ANY OF THE WORK SO INVOLVED. ALL WORK IS TO BE CO-ORDINATED SO THAT THE CO-OPERATION BETWEEN ALL TRADES, WHERE REQUIRED, IS ACCOMPLISHED. 2. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD, REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO STARTING WORK AND CONTRACTOR SHALL MAKE AND ADD ALL CORRECTIONS NECESSARY DUE TO NEGLIGENT FIELD VERIFICATION AT HIS SOLE EXPENSE. 3. CONTRACTOR TO VERIFY SIZE OF ALL FRAMED OPENINGS UPON COMPLETION OF FRAMING AND PRIOR TO ORDERING. 4. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAR OF THE ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS EMPLOYEES OR WORK AND AT THE COMPLETION OF THE WORK, SHALL REMOVE ALL RUBBISH, DEBRIS EQUIPMENT AND SURPLUS MATERIALS FROM IN AND AROUND THE BUILDING AND LEAVE THE WORK "BROOM CLEAN". 5. PROVIDE PEDESTRIAN PROTECTION 6. PATCH AND REPAIR ALL SURFACES DISRUPTED OR DAMAGED DURING CONSTRUCTION TO EXACTLY MATCH EXISTING ADJACENT SURFACES. 7. OWNERS OF ADJACENT PROPERTIES THAT MUST UNDERPIN THEIR BUILDINGS DUE TO THE PROPOSED EXCAVATION SHALL BE NOTIFIED IN WRITING TEN DAYS PRIOR TO BEGINNING THE EXCAVATION. COPIES OF THESE NOTIFICATION LETTERS SHALL BE PROVIDED TO THE CITY PRIOR TO BEGINNING THE EXCAVATION. 8. RESPONSIBLE CERTIFIED ENGINEERING GEOLOGIST WILL INSPECT AND APPROVE ALL GRADING AND EXCAVATIONS PRIOR TO PLACEMENT OF FORMS, REBAR OR CONCRETE 9. LICENSED ENGINEER THAT PREPARED THE DRAINAGE PLAN SHALL CERTIFY AT THE COMPLETION OF THE PROJECT THAT THE SITE DRAINAGE IS IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED DRAINAGE PLAN. 10. DESIGNER EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THE ATTACHED DRAWINGS LISTED. THESE DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN PERMISSION OF THE DESIGNER. 1. In the case of emergency, call at Work Phone # or Home Phone # 2. Sediment from areas disturbed by construction shall be retained on site using structural controls to the maximum extent practicable. 3. Stockpiles of soil shall be properly contained to minimize sediment transport from the site to streets, drainage facilities or adjacent properties via runoff, vehicle tacking, or wind. 4. Appropriate BMP’s for construction related materials, wastes, spills shall be implemented to minimize transport from the site to streets, drainage facilities, or adjoining properties by wind or runoff. 5. Runoff from equipment and vehicle washing shall be contained at construction sites unless treated to reduce or remove sediment and other pollutants. 6. All construction contractor and subcontractor personnel are to be made aware or the required best management practices and good housekeeping measures for the project site and any associated construction staging areas. 7. At the end of each day of construction activity all construction debris and waste materials shall be collected and properly disposed in trash or recycle bins. 8. Construction sites shall be maintained in such a condition that an anticipated storm does not carry wastes or pollutants off the site. Discharges of material other than stormwater only when necessary for performance and completion of construction practices and where they do not: cause or contribute to a violation of any water quality standard; cause or threaten to cause pollution, contamination, or nuisance; or contain a hazardous substance in a quantity reportable under Federal Regulations 40 CFR Parts 117 and 302. 9. Potential pollutants include but are not limited to: solid or liquid chemical spills; wastes from paints, stains, sealants, glues, limes, pesticides, herbicides, wood preservatives and solvents; asbestos fibers, paint flakes or stucco fragments; fuels, oils, lubricants, and hydraulic, radiator or battery fluids; fertilizers, vehicle/equipment wash water and concrete wash water; concrete, detergent or floatable wastes; wastes from any engine/equipment steam cleaning or chemical degreasing and superchlorinated potable water line flushing. During construction, permittee shall dispose of such materials in a specified and controlled temporary area onsite, physically separated from potential stormwater runoff, with ultimate disposal in accordance with local, state and federal requirements. 10. Dewatering of contaminated groundwater, or discharging contaminated soils via surface erosion is prohibited. Dewatering of noncontaminated groundwater requires a National Pollutant Discharge Elimination System Permit from the respective State Regional Water Quality Control Board. 11. Graded areas on the permitted area perimeter must drain away from the face of slopes at the conclusion of each working day. Drainage is to be directed toward desilting facilities. 12. The permittee and contractor shall be responsible and shall take necessary precautions to prevent public trespass onto areas where impounded water creates a hazardous condition. 13. The permittee and contractor shall inspect the erosion control work and insure that the work is in accordance with the approved plans. 14. The permittee shall notify all general contractors, subcontractors, material suppliers, lessees, and property owners: that dumping of chemicals into the storm drain system or the watershed is prohibited. 15. Equipment and workers for emergency work shall be made available at all times during the rainy season. Necessary materials shall be available on site and stockpiled at convenient locations to facilitate rapid construction of temporary devices when rain is imminent. 16. All removable erosion protective devices shall be in place at the end of each working day when the 5 Day Rain Probability Forecast exceeds 40%. 17. Sediments from areas disturbed by construction shall be retained on site using an effective combination of erosion and sediment controls to the maximum extent practicable, and stockpiles of soil shall be properly contained to minimize sediment transport from the site to streets, drainage facilities or adjacent properties via runoff, vehicle tracking, or wind. 18. Appropriate BMPs for constructionrelated materials, wastes, spills or residues shall be implemented and retained on site to minimize transport from the site to streets, drainage facilities, or adjoining property by wind or runoff. EX P . 5 / 3 1 / 2 5 C 3 5 7 7 9 A F ET O C A ORNI IL F TSABR A D L E Y F O W E R S LICENSED ARCHITECT Scale AR C H I T E C T : FO W E R S A R C H I T E C T S , I N C BR A D F O W E R S 38 2 P R O S P E C T P A R K TU S T I N , C A 9 2 7 8 0 71 4 -36 6 -12 5 1 br a d f o w e r s d e s i g n @ g m a i l . c o m 10 / 3 0 / 2 0 2 4 9 : 2 2 : 0 8 P M T1 TI T L E S H E E T 10 0 0 W E S T M A C A R T H U R UN I T 7 2 , S A N T A A N A , C A 92 7 0 7 RA I L I N G U P G R A D E RAILING UPGRADE 1000 WEST MACARTHUR UNIT 72, SANTA ANA, CA 92707 PROJECT DESCRIPTION REMOVE AND REPLACE EXISTING GUARDRAIL CODE ANALYSIS CODE: CBC 2022, CRC, CEC, CMC, CPC, CALIFORNIA GREEN BUILDING STANDARDS CODE AND 2022 ENERGY EFFICIENCT STANDARDS. CODES AND LOCAL AMENDMENTS CONSTRUCTION TYPE: V-B OCCUPANCY: R-2 ZONE: STORIES: 2 FIRE SPRINKLER: NO SITE PLANSCALE: N.T.S SHEET INDEXPROJECT TEAM T1 TITLE SHEET A1 DEMOLITION PLAN & ELEVATION A2 PROPOSED PLAN, ELEVATIONS & DETAILS SN-1 GENERAL NOTES SN-2 TYPICAL DETAILS S-1 DECK AND ROOF FRAMING PLAN N S EW N OWNER'S REP: CECILIA PLEITEZ, COMMUNITY MANAGER THE MANAGMENT COMPANY 5 PETERS CANYO9N RD. STE 200 IRVINE, CA 92606 TEL: (714) 285-2626 cecilia.pleitez@managementtrust.com ARCHITECT: FOWERS ARCHITECT, INC BRAD FOWERS 382 PROSPECT PARK TUSTIN, CA 92780 TEL: (714) 366-1251 STRUCTURAL ENGINEER: JJS STRUCTURAL INC. JASON SKUDLARSKI PE. 9751 OLYMPIC DRIVE HUNTINGTON BEACH, CA 92646 TEL: (714) 496-6772 UNIT 72 AREA OF WORK W. MACARTHUR BLVD. RO S E W O O D A V E . ORION AVE. No . De s c r i p t i o n Da t e Bldg #101121840 APPROVALS: PLNG - F. Arias BLDG - CSG 1000 W MacArthur Blvd Unit# 721/23/2025 UP UP DEMO WALL NEW WALL EXISTING WALL TO REMAIN DEMO ROOF A1 3 A1 3 REMOVE (E) RAILING CEILING 8’ −1" LEVEL 1 0’ −0" ROOF 20’ −8" LEVEL 2 9’ −0" CEILING 2 17’ −1" EX P . 5 / 3 1 / 2 5 C 3 5 7 7 9 A F ET O C A ORNI IL F TSABR A D L E Y F O W E R S LICENSED ARCHITECT Scale AR C H I T E C T : FO W E R S A R C H I T E C T S , I N C BR A D F O W E R S 38 2 P R O S P E C T P A R K TU S T I N , C A 9 2 7 8 0 71 4 -36 6 -12 5 1 br a d f o w e r s d e s i g n @ g m a i l . c o m 1/4" = 1'-0" 10 / 3 0 / 2 0 2 4 9 : 2 2 : 0 6 P M A1 DE M O L I T I O N P L A N & EL E V A T I O N 10 0 0 W E S T M A C A R T H U R UN I T 7 2 , S A N T A A N A , C A 92 7 0 7 RA I L I N G U P G R A D E N S EW N LEGEND 1/4" = 1’−0"1 FIRST FLOOR - DEMOLITION PLAN 1/4" = 1’−0"2 SECOND FLOOR - DEMOLITION PLAN N S EW N 1/4" = 1’−0"3 NORTH ELEVATION - DEMOLITION No. Description Date 1000 W MacArthur Blvd Unit# 721/23/2025 UP UP A1 3 A2 3 4 A2CUT BACK (E) 4X6 FLUSH TO BEAM (N) 4X6 JOIST SISTERED TO EXISTING JOIST. A1 3 A2 3 4 A2 CEILING 8’ −1" LEVEL 1 0’ −0" ROOF 20’ −8" LEVEL 2 9’ −0" CEILING 2 17’ −1" 3' - 6 " 1' - 4 " 1' - 0 " 4 A2 1X6 FLAT , TYP2x2 BALUSTER TYP2x6 POST TYP A2 5 LEVEL 2 9’ −0" 2X2 POST 2X6 POST 2X6 FLAT 1' - 4 " (N) 4X6 JOIST SISTERED TO EXISTING JOIST. (E) 6X10 BEAM (E) 6X6 POST (E) 6X6 POST (E) STEEL SADDLE BRACKET, REFER TO STRUCTURAL (E) DECKING, GC TO VERIFY DIMENSIONS 3' - 6 " AL I G N 2X4 LEVEL 2 9’ −0" 3' - 6 " 4" MAX. 2X2 POST TYP. 2X6 POST 2X6 FLAT (E) 6X6 POST (E) STEEL SADDLE BRACKET, REFER TO STRUCTURAL 2X4 (N) 4X6 JOIST SISTERED TO EXISTING JOIST. (E) 4X6 JOIST EX P . 5 / 3 1 / 2 5 C 3 5 7 7 9 A F ET O C A ORNI IL F TSABR A D L E Y F O W E R S LICENSED ARCHITECT Scale AR C H I T E C T : FO W E R S A R C H I T E C T S , I N C BR A D F O W E R S 38 2 P R O S P E C T P A R K TU S T I N , C A 9 2 7 8 0 71 4 -36 6 -12 5 1 br a d f o w e r s d e s i g n @ g m a i l . c o m As indicated 10 / 3 0 / 2 0 2 4 9 : 2 2 : 0 7 P M A2 PR O P O S E D P L A N , EL E V A T I O N S & D E T A I L S 10 0 0 W E S T M A C A R T H U R UN I T 7 2 , S A N T A A N A , C A 92 7 0 7 RA I L I N G U P G R A D E 1/4" = 1’−0"1 FIRST FLOOR - PROPOSED PLAN 1/4" = 1’−0"2 SECOND FLOOR - DEMOLITION PLAN N S EW N N S EW N 1/4" = 1’−0"3 NORTH ELEVATION - PROPOSED 1 1/2" = 1’−0"4 RAILING SECTION 1 1/2" = 1’−0"5 ENLARGED RAILING No. Description Date 1000 W MacArthur Blvd Unit# 721/23/2025 SHEET INDEXGENERAL NOTES SN1 GENERAL NOTES SN2 TYPICAL DETAILS S-1 DECK AND ROOF FRAMING PLANS RISK CATEGORY II SS = 1.282 R = 6.5 IMPORTANCE FACTOR 1.0 S1 = 0.460 SEISMIC DESIGN CATEGORY D SDS = 1.025 SITE CLASS D SD1 = N/A BASIC SEISMIC FORCE RESISTING SYSTEM - LIGHT FRAMED WALLS SHEATHED w/ WOOD STRUCTURAL PANELS ANALYSIS PROCEDURE USED - EQUIVALENT LATERAL FORCE PROCEDURE 15/32" APA RATED SHEATHING, EXPOSURE 1 WITH A MIN. PANEL INDEX OF 32/16 BOUNDARY NAILING (B.N.)8d COMMON NAILS AT 6"o/c EDGE NAILING (E.N.)8d COMMON NAILS AT 6"o/c FIELD NAILING (F.N.)8d COMMON NAILS AT 12"o/c 23/32" APA RATED STURD-I-FLOOR, T&G, EXPOSURE 1 WITH A MIN. SPAN RATING OF 24". PLYWOOD MUST CONFORM WITH DOC PS1 OR PS2. BOUNDARY NAILING (B.N.)10d COMMON NAILS AT 6"o/c EDGE NAILING (E.N.)10d COMMON NAILS AT 6"o/c FIELD NAILING (F.N.)10d COMMON NAILS AT 12"o/c USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING WITH ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. GENERAL REQUIREMENTS 1.WORK PERFORMED SHALL COMPLY WITH THE 2022 CBC AND ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS GOVERNING THE SITE OF WORK. 2.STANDARD SPECIFICATIONS OF ASTM ARE NOTED HEREIN AND AS REQUIRED BY THE BUILDING CODE. 3.ALL WORK NEEDS TO BE PERFORMED BY QUALIFIED AND EXPERIENCED CONTRACTORS FAMILIAR WITH THIS TYPE OF PROJECT. 4.IN CASE OF CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 5.THE ENGINEER OR ARCHITECT OF RECORD MUST BE NOTIFIED IMMEDIATELY SHOULD ANY QUESTION ARISE OR ANY DISCREPANCY BE FOUND PERTAINING TO THE WORKING DRAWINGS. 6.ON-SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS IS THE RESPONSIBILITY OF THE CONTRACTORS AND SUB-CONTRACTORS. NOTED DIMENSIONS TAKE PRECEDENCE OVER THE SCALE OF DRAWINGS. 7.NO DEVIATIONS FROM THESE PLANS SHALL BE MADE WITHOUT THE WRITTEN CONSENT OF JJS STRUCTURAL, INC. 8.THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORT, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT HAS NOT BEEN CONSIDERED BY THE ARCHITECT OR ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. THE BUILDER HAS CONTRACTED WITH JJS STRUCTURAL, INC. FOR THE LIMITED SERVICES OF PROVIDING THE MINIMUM STRUCTURAL ENGINEERING DRAWINGS REQUIRED, WHEN COMBINED WITH THE OTHER BUILDING CONSULTANTS DRAWINGS TO OBTAIN A BUILDING PERMIT FOR THIS PROJECT. 9.THE BUILDER HAS REQUESTED, ACCEPTS AND REPRESENTS THAT HE WILL SELECT ALL MATERIALS AND MANUFACTURERS, QUALIFY AND SELECT ALL INSTALLERS, DIRECT ALL WAYS AND MEANS OF CONSTRUCTION AND PROVIDE ALL SUB-CONTRACTORS ADDITIONAL INFORMATION, ABOVE AND BEYOND THESE DRAWINGS, REQUIRED TO COMPLETE THE PROJECT IN CONFORMANCE WITH ALL GOVERNING AGENCIES AND THE WORK WILL MEET OR EXCEED ACCEPTED INDUSTRY STANDARDS. DESIGN CRITERIA 1.GRAVITY LOADS: 1.1.EX'G ROOF TILE ASSUMED TO BE CONCRETE (WEIGHT = 10.0psf, MAX) 1.2.EX'G DECK ASSUMED TO HAVE DEX-O-TEX, OVER 3 4" SHT'G, OVER 2x6 DECKING (WEIGHT = 8.4psf, MAX.) 2.SEISMIC DESIGN PARAMETERS 3.WIND DESIGN PARAMETERS 4.LUMBER GRADES: 5.ROOF SHEATHING: 6.FLOOR SHEATHING REINFORCED CONCRETE 1.ALL REINFORCED CONCRETE MATERIALS AND CONSTRUCTION SHALL CONFORM TO CBC CHAPTER 19. 2.CEMENT AND CONCRETE AGGREGATES SHALL CONFORM TO CBC SECTION 1903. 3.ADMIXTURES CONTAINING CALCIUM CHLORIDES SHALL NOT BE USED. 4.CONCRETE SHALL BE TO THE STRENGTH AND SLUMP SPECIFIED AND CONSIST OF PORTLAND CEMENT ASTM C-150. AGGREGATES MUST CONFORM TO ASTM C-33 AND WATER MUST BE CLEAN AND POTABLE. 5.THE MINIMUM COMPRESSIVE STRENGTH (f'c) OF CONCRETE SHALL BE 2500 psi AT 28 DAYS, U.N.O. 5.1.THE MINIMUM COMPRESSIVE STRENGTH (f'c) OF CONCRETE SHALL BE 3000 psi AT 28 DAYS IF STRUCTURE IS OVER TWO-STORIES IN HEIGHT 6.TYPE V CEMENT w/ A MAX. W:C RATIO OF 0.45 MUST BE USED IF SOIL CONTAINS SULFATE, PER CBC SECTION 1904 & ACI 318-14, TABLE 19.3.2.1. MIN. f'c = 4500 psi AT 28 DAYS. SPECIAL INSPECTION IS NOT REQUIRED. REFER TO CBC SECTION 1904, SOILS AND CORROSION ENGINEERS RECOMMENDATIONS FOR CONCRETE EXPOSED TO CORROSIVE ELEMENTS. 7.SPECIAL INSPECTION IS REQUIRED FOR CONCRETE w/ f'c > 2500 psi UNLESS IT'S SOLELY USED FOR ITEM 6 ABOVE. 8.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 & #4 AND GRADE 60 FOR SIZES #5 & LARGER. 9.ALL REINFORCING STEEL, DOWELS, HOLDOWNS AND OTHER INSERTS MUST BE SECURED IN PLACE AND APPROVED BY THE BUILDING OFFICIAL PRIOR TO CONCRETE BEING POURED. 10.MIN. CONCRETE COVER FOR REINFORCING IS AS FOLLOWS: 10.1.CONC. PLACED AGAINST EARTH, NOT FORMED 3" 10.2.CONCRETE FORMED OR TROWELED 2" 10.3.WALLS AND CURBS 1-1/2" 10.4.SLABS ON GRADE AT CENTER ROOF LOADS DECK LOADS DEAD LOAD 18 psf 13 psf LIVE LOAD 20 psf 60 psf TOTAL LOAD 38 psf 73 psf 2x AND 4x MEMBERS DFL #2 6x AND 8x MEMBERS DFL #1 STUDS (9'-0" IN HT. OR LESS)DFL STUD GRADE STUDS (TALLER THAN 9'-0")DFL #2 TOP AND SILL PLATES DFL #2 OR BETTER* *MUD SILLS IN CONTACT WITH CONCRETE ARE TO BE PRESSURE TREATED FOUNDATION 1.ALL CONTINUOUS FOOTINGS MUST HAVE 5/8" Ø. x MIN. 12" ANCHOR BOLTS EMBEDDED 7" INTO CONCRETE AND SPACED NO MORE THAN 48"o/c, U.N.O. ONE ANCHOR BOLT MUST BE LOCATED BETWEEN 4" & 12" FROM THE END OF ALL SILL PLATES AND THERE MUST BE AT LEAST (2) ANCHOR BOLTS PER SILL PLATE / SHEAR WALL. 2.ANCHOR BOLTS AT SHEAR WALLS MUST HAVE A 3"x3"x0.229" THK. PLATE WASHER INSTALLED BETWEEN THE NUT AND SILL PLATE. 2.1.THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED w/ A WIDTH OF UP TO 3 16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 13 4", PROVIDED A STD. CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. 3.INTERIOR NON-SHEAR WALLS SHALL BE ANCHORED TO THE CONCRETE SLAB WITH SIMPSON PHNW SERIES 0.145" DIA. SHOT PINS, SPACED AT 16"o/c. PROVIDE MINIMUM 114" EMBED. INTO SLAB. REFER TO ICC-ES ESR-2138 FOR INSTALLATION INFORMATION. 4.ALL HOLDOWNS MUST BE INSTALLED PER THE LATEST ICC-ES REPORTS AND TIED IN PLACE JUST PRIOR TO FOUNDATION INSPECTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL ANCHORS AS DIMENSIONS ARE NOT FURNISHED IN THESE STRUCTURAL PLANS. 5.PROVIDE #3 x 24" DOWELS AT 24"o/c ALL CONCRETE STOOPS AND PORCHES. 6.IF THERE IS A SOILS ENGINEER ON THE PROJECT, ALL FOOTING, SLAB AND REBAR REQUIREMENTS AS WELL AS EXPANSIVE SOILS REQUIREMENTS MUST BE VERIFIED. THE MORE STRINGENT GUIDELINES SHALL GOVERN. 7.CONTRACTOR SHALL DAMPEN SLAB UNDERLAYMENT OF SAND/MEMBRANE JUST PRIOR TO CONCRETE PLACEMENT TO ASSIST IN UNIFORM CONCRETE CURING. SLABS MUST NOT BE POURED DURING OR IMMEDIATELY AFTER RAINSTORMS. THE SPECIFIED SAND OVER VISQUEEN SHOULD NOT BE SATURATED AT THE TIME OF THE CONCRETE POUR. ANY FREE WATER TRAPPED IN THE SAND LAYER MUST BE REMOVED PRIOR TO THE CONCRETE POUR. 8.THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE LEVEL, CLEAN AND FREE OF LOOSE MATERIAL OR WATER WHEN CONCRETE IS PLACED. OVER EXCAVATION SHALL BE FILLED WITH CONCRETE OR PROPERLY COMPACTED FILL THAT HAS BEEN TESTED AND APPROVED BY THE SOILS ENGINEER. BACKFILL SHALL NOT BE PLACED UNTIL SUPPORTING FOUNDATIONS, WALLS AND SLAB HAVE ATTAINED SUFFICIENT STRENGTH TO SUPPORT LATERAL SOIL PRESSURE. 9.CONCRETE PLACEMENT SHALL BE MONOLITHIC IN ONE CONTINUOUS OPERATION, UNIFORMLY PLACED, MUST BE VIBRATED AND WELL CONSOLIDATED, U.N.O. FOR NON-MONO POUR, USE #4 DOWELS AT 18"o/c, MIN. 18" INTO SLAB AND 12" INTO 1ST. POUR. 10.FLOOR SLAB SHALL BE POURED LEVEL TO 1/8" IN 10'. 11.REQUIREMENTS FOR THE SITE AND PAD PREPARATION, PRE-SATURATION OF SUBGRADE SOILS, DAYLIGHT SETBACK OF EXTERIOR FOOTINGS FROM ANY DESCENDING SLOPE SHALL COMPLY WITH THE SOIL ENGINEER'S RECOMMENDATIONS, AS REQUIRED. 12.REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, DEPRESSIONS, SLOPE, SHELVES, PATIOS, STOOPS AND PORCHES NOT SHOWN. 13.DO NOT WALK ON THE SLAB UNTIL AT LEAST 24 HOURS AFTER THE CONCRETE HAS BEEN POURED. WALL FRAMING MAY COMMENCE 4-5 DAYS AFTER THE CONCRETE POUR AND ROOF/FLOOR FRAMING 7-10 DAYS AFTER. THE ROOF MAY NOT BE LOADED UNTIL AT LEAST 14 DAYS AFTER THE CONCRETE HAS BEEN POURED. 14.NO PIPES OR CONDUITS SHALL EXTEND UNDER ISOLATED COLUMN FOOTINGS OR UNDER CONTINUOUS WALL FOOTINGS UNLESS SPECIFICALLY DETAILED OR APPROVED BY JJS STRUCTURAL, INC. AND THE BUILDING OFFICIAL. 15.SHEAR WALL ANCHOR BOLTS AND HOLDOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 16.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE TREATED WOOD, CONFORMING TO AWPA U1 AND M4. 17.ALL BOLTS IN CONCRETE MUST CONFORM TO ASTM F1554, GRADE 36, U.N.O. 18.ALL HIGH STRENGTH BOLTS MUST CONFORM TO ASTM A449 (UP TO 1"Ø) AND ASTM A193 B7 OR ASTM F1554 GRADE 105 (118" & 114"Ø). FRAMING 1.ALL STRUCTURAL WOOD SHALL BE OF DOUGLAS FIR LARCH SPECIES WITH A MAXIMUM MOISTURE CONTENT OF 19% AT THE TIME OF CONSTRUCTION. WOOD SHALL CONFORM WITH DOC PS20. 2.CONVENTIONAL CONSTRUCTION REQUIREMENTS OF CHAPTER 23 FOR LIGHT FRAMED CONSTRUCTION SHALL BE FOLLOWED AS REQUIRED. 3.ALL FRAMING, BRACING, NAILING, NOTCHING, DRILLING OR BORING SHALL BE IN ACCORDANCE WITH THE BUILDING CODE UNLESS MORE STRINGENT REQUIREMENTS ARE REQUIRED BY THE LOCAL JURISDICTION. 4.TOP PLATES OF ALL WOOD STUDS WALLS MUST CONSIST OF (2) 2x MEMBERS THE SAME WIDTH AS THE STUDS, U.N.O. TOP PLATES SHALL LAP A MINIMUM OF 48" AND BE SPLICED WITH A MINIMUM OF (8) 16d NAILS, SPACED AT 12"o/c, MAX. 5.ALL SHEAR PANELS MUST HAVE CONTINUOUS SHEATHING FROM ONE END TO THE OTHER AND FROM PLATE TO PLATE. 6.NON-BEARING WALLS ARE TO BE FRAMED WITH 2x4 STUDS AT 24"o/c FOR A MAXIMUM HEIGHT OF 14'-0" AND 2x6 STUDS AT 24"o/c FOR A MAXIMUM HEIGHT OF 20'-0". TALLER WALLS AND BEARING WALLS WILL BE DESIGNED ON A CASE BY CASE BASIS (SECTION 2308.5.1). 7.NON-BEARING HEADERS: USE 2x4 FOR A MAXIMUM OPENING WIDTH OF 3'-0", 2-2x4 FOR AN OPENING WIDTH OF 6'-0', MAX. AND 4x6 FOR OPENINGS UP TO 12'-0" WIDE. 8.2x DFL #2 CEILING JOISTS MAY BE USED TO SUPPORT NO MORE THAN 6 PSF DEAD LOAD AND 10 PSF LIVE LOAD AS FOLLOWS: 2x4'S AT 16"o/c - MAX. SPAN = 9'-0" 2x6'S AT 16"o/c - MAX. SPAN = 13'-0" 2x8'S AT 16"o/c - MAX. SPAN = 14'-6" 2x10'S AT 16"o/c - MAX. SPAN = 15'-9" THIS IS BASED ON A DRYWALL CEILING AND A MAXIMUM DEFLECTION OF L/240. 9.ALL NAILS SHALL BE SINKER NAILS AND STAGGERED EXCEPT AS SPECIFIED IN CBC TABLE 2304.10.2, U.N.O. 10.FASTENERS, INCLUDING NUTS , WASHERS & CONNECTORS IN CONTACT w/ PRESERVATIVE TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A153. 11.ALL MACHINE BOLTS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. BOLT HOLES SHALL BE DRILLED 132" - 116" LARGER THAN THE BOLT DIAMETER. 12.FOR NON-SHEAR WALL APPLICATIONS, ROUND WASHERS SHALL BE USED ON ALL BOLTS AND SHALL CONFORM WITH ANSI/ASME STANDARD B18.2.1. USE MIN. 13 8" Ø x 7 64" THICK WASHER FOR 12"Ø BOLT, 13 4"Ø x 9 64" THICK WASHER FOR 5 8"Ø BOLT AND 212"Ø x 1164" THICK WASHER FOR 1" Ø BOLT. 13.MANUFACTURED HARDWARE SPECIFIED ON THE DRAWINGS ARE TO BE SIMPSON STRONG TIE OR EQUAL. FOLLOW ALL MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS FOR INSTALLATION AND HANDLING OF THE PRODUCT. 14.ALL JOIST HANGERS SHALL BE SIMPSON U HANGERS (OR EQUAL) AND ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS (OR EQUAL), U.N.O. ON PLANS. FOLLOW MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION. 15.ALL LEDGERS SHALL BE SPLICED WITH AN ST22 STRAP, U.N.O. 16.ROOF/FLOOR SHEATHING & SHEAR PANELS MAY BE PLYWOOD OR OSB. REFER TO DESIGN CRITERIA & SHEAR WALL SCHEDULE FOR ADD'L INFORMATION. 17.ALL NAILING SHALL CONFORM TO CBC TABLE 2304.10.2 18.ALL WOOD STRUCTURAL PANELS SHALL CONFORM TO DOC PS1 OR DOC PS2 19.WOOD FRAMING MEMBERS (E.G. BEAMS AND POSTS) SHALL BE PRESSURE TREATED WHEN EXPOSED TO WEATHER, PER CBC 2304.12.2.3 CONCRETE MASONRY 1.ALL CONCRETE MASONRY MATERIALS & CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 21 OF THE CBC. 2.MORTAR SHALL CONFORM TO ASTM C 270 TYPE S OR M, PER CBC SECTION 2103.8. 3.GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602 / ACI 530.1 / ASCE 6, PER CBC SECTION 2103.12. A MINIMUM 28-DAY COMPRESSION STRENGTH OF 2000 PSI MUST BE ATTAINED UNLESS THE SPECIFIED MASONRY UNITS REQUIRE A GREATER STRENGTH. 4.THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, f'm, SHALL BE 1500 PSI, U.N.O. 5.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 SHALL BE USED FOR SIZES #3 & #4 AND GRADE 60 FOR SIZES #5 AND LARGER. STRUCTURAL STEEL 1.ALL STRUCTURAL STEEL MATERIALS AND CONSTRUCTION SHALL CONFORM TO CBC CHAPTER 22. 2.ALL STEEL SHALL BE PRIMED w/ A RUST RESISTANT PRIMER AND CONFORM TO ASTM A36 (Fy=36ksi), U.N.O. 2.1.W SHAPES SHALL CONFORM TO ASTM A992 (Fy=50ksi) 2.2.RECTANGULAR HSS TUBING SHALL CONFORM TO ASTM A500, GRADE C (Fy=50ksi) 2.3.ROUND HSS TUBING SHALL CONFORM TO ASTM A500, GRADE C (Fy=46ksi) 2.4.STEEL PIPE SHALL CONFORM TO ASTM A53, GRADE B (Fy=35ksi) 3.ALL STRUCTURAL WELDING PROCEDURES AND MATERIALS SHALL CONFORM TO CBC SECTION 2204.1. ALL WELDING SHALL BE BY THE SHIELDED METAL ARC WELDING PROCESS OR THE SUBMERGED ARC WELDING PROCESS USING E70XX-LOW HYDROGEN ELECTRODES, U.N.O. 4.ALL BOLTS FOR STEEL MEMBER CONNECTIONS SHALL CONFORM TO CBC SECTION 2204.2 & ASTM A325N, U.N.O. 5.HOLES FOR BOLTS MUST BE DRILLED OR PUNCHED AND SHALL BE 1/16" LARGER THAN THE BOLT DIAMETER. 6.ALL SHOP WELDING AND FABRICATION MUST BE DONE IN A SHOP CERTIFIED BY AISC QUALITY CERTIFICATION PROGRAM AND APPROVED BY THE BUILDING OFFICIAL. ALL FIELD WELDING MUST BE PERFORMED BY A CERTIFIED WELDER AND A SPECIAL INSPECTOR SHALL CONTINUOUSLY INSPECT ALL STRUCTURAL FIELD WELDING. BOTH SHALL BE APPROVED BY THE BUILDING OFFICIAL. 7.WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDING PROCEDURE SPECIFICATION (WPS) AS REQUIRED IN AWS D1.1 AND APPROVED BY THE ENGINEER OF RECORD. SPECIFY THE REQUIRED "WPS" ON THE PLANS. 8.ALL FILLER (WELD) METAL SHALL HAVE MINIMUM CVN OF 20 FT-LBS AT -20 DEGREES FAHRENHEIT AND 40 FT-LBS AT 70 DEGREES FAHRENHEIT. 9.THE STRUCTURAL STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR ALL STEEL MEMBERS TO THE ENGINEER OF RECORD FOR REVIEW. GLUED LAMINATED LUMBER 1.GLUE LAMINATED LUMBER SHALL BE MANUFACTURED, FABRICATED AND SHALL BE INSPECTED FOR QUALITY CONTROL IN ACCORDANCE WITH ANSI/APA-190.1 AND ASTM D3737, STRUCTURAL GLUED - LAMINATED TIMBER. FABRICATION OF TIMBERS SHALL BE USING MATERIALS AT 16% OR LOWER MOISTURE CONTENT AND SHALL UTILIZE ADHESIVE APPROVED FOR WET CONDITION OF SERVICE. 2.GLUE LAMINATED TIMBERS SHALL BE VISUALLY GRADED WESTERN SPECIES WITH A 24F-V4 COMBINATION FOR STANDARD APPLICATIONS AND 24F-V8 FOR CANTILEVERED APPLICATIONS. 3.GLUE LAMINATED TIMBERS SHALL BE CLEARLY STAMPED OR MARKED AND SHALL BE ACCOMPANIED BY A CERTIFICATE OF COMPLIANCE INDICATING CONFORMANCE TO ANSI/APA-190.1. APPROVED CERTIFICATE OF COMPLIANCE ISSUING AGENCIES ARE THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE APA - THE ENGINEERED WOOD ASSOCIATION. A COPY OF THE CERTIFICATE OF COMPLIANCE SHALL BE PRESENTED TO THE INSPECTOR PRIOR TO INSTALLATION, WITH COPIES FORWARDED TO THE STRUCTURAL ENGINEER AND ARCHITECT. 4.CAMBER REQUIREMENTS SHALL BE AS INDICATED IN THE CONSTRUCTION DOCUMENTS OR SHALL HAVE A STANDARD CAMBER WITH A RADIUS OF CURVATURE OF 3500 FEET PLUS OR MINUS 200 FEET. 5.GLUED-LAMINATED TIMBERS EXPOSED TO WEATHER SHALL BE PRESSURE TREATED AND CONFORM TO AMERICAN WOOD PRESERVERS ASSOCIATION (AWPA), AWPA STANDARD C-28, PRESSURE TREATMENT OF STRUCTURAL GLUED-LAMINATED TIMBER OR AITC STANDARD 109, STANDARD PRESERVATIVE TREATMENT OF STRUCTURAL GLUED-LAMINATED TIMBER. AMMONIUM COPPER ZINC ARSENATE SHALL BE USED AS THE TREATMENT SOLUTION. TREATMENT TYPE AND INSPECTION AGENCY SHALL BE CLEARLY STAMPED ON TREATED MATERIAL. TREATMENT AGENCY TO CONFORM TO AMERICAN WOOD PRESERVERS BUREAU (AWPB) AWPB STANDARD LP. EXTERIOR EXPOSED SURFACES SHALL BE COATED OR PAINTED WITH MINIMUM TWO COATS OF SEALER OR COVERED BY FRAMING OR DRYWALL FOR INTERIOR APPLICATIONS. Fastening Schedule (2304.10.2) Description of Building Elements Number & Type of Fastener Spacing & Location Roof 1. Blk'g between ceiling joists, rafters or trusses to top plate or other framing below 3-8d common (212"x0.131")Each end, toenail Blk'g between rafters or truss not at the wall top plate, to rafter or truss 2-8d common (212"x0.131")Each end, toenail 2-16d common (312"x0.162")End nail Flat blk'g to truss and web filler 16d common (312"x0.162")Face nail 2.Ceiling joists to top plate 3-8d common (212"x0.131"); or 3-10d box (3"x0.128")Face nail 3.Ceiling joists not attached to parallel rafter, laps over partitions (no thrust) 3-16d common (312"x0.162"); or 4-10d box (3"x0.128")Face nail 4.Ceiling joist attached to parallel rafter (heel joint)Per plan or Table 2308.7.3.1 Face nail 5.Collar tie to rafter 3-10d common (3"x0.148"); or 4-10d box (3"x0.128")Face nail 6.Rafter or roof truss to top plate 3-10d common (3"x0.148"); or 3-16d box (312"x0.135"); or 4-10d box (3"x0.128") Toenail1 7.Roof rafters to ridge valley or hip rafters; or roof rafter to 2-inch ridge beam 2-16d common (312"x0.162"); or 3-10d box (3"x0.128")End nail 3-10d common (312"x0.148"); or 4-16d box (312"x0.135"); or 4-10d box (3"x0.128") Toenail Wall 8.Stud to stud (not at braced wall panels) 16d common (312"x0.162"); or 24"o/c face nail 10d box (3"x0.128")16"o/c face nail 9. Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 16d common (312"x0.162"); or 16"o/c face nail 16d box (312"x0.135")12"o/c face nail 10.Built-up header (2" to 2" header) 16d common (312"x0.162"); or 16"o/c each edge, face nail 16d box (312"x0.135")12"o/c each edge, face nail 11.Continuous header to stud 4-8d common (212"x0.131"); or 4-10d box (3"x0.128")Toenail 12.Top plate to top plate 16d common (312"x0.162"); or 16"o/c face nail 10d box (3"x0.128")12"o/c face nail 13.Top plate to top plate, at end joints 8-16d common (312"x0.162"); or 12-10d box (3"x0.128") Each side of end joint, face nail (minimum 24" lap splice length each side of end joint) 14.Bottom plate to joist, rim joist, band joist or blk'g (not at braced wall panels) 16d common (312"x0.162"); or 16"o/c face nail 16d box (312"x0.135")12"o/c face nail 15.Bottom plate to joist, rim joist, band joist or blk'g at braced wall panels 2-16d common (312"x0.162); or 3-16d box (312"x0.135")16"o/c face nail 16.Stud to top or bottom plate 4-8d common (212"x0.131"); or 4-10d box (3"x0.128")Toenail 2-16d common (312"x0.162"); or 3-10d box (3"x0.128")End nail 17.Top plates, laps at corners & intersections 2-16d common (312"x0.162"); or 3-10d box (3"x0.128")End nail 18.1" brace to each stud and plate 2-8d common (212"x0.131"); or 2-10d box (3"x0.128")Face nail 19.1"x6" sheathing to each bearing 2-8d common (212"x0.131"); or 2-10d box (3"x0.128")Face nail 20.1"x8" and wider sheathing to each bearing 3-8d common (212"x0.131"); or 3-10d box (3"x0.128")Face nail Floor 21.Joist to sill, top plate or girder 3-8d common (212"x0.131"); or floor 3-10d box (3"x0.128")Toenail 22.Rim joist, band joist, or blk'g to top plate, sill or other framing below 8d common (212"x0.131"); or 10d box (3"x0.128")6"o/c, toenail 23.1"x6" subfloor or less to each joist 2-8d common (212"x0.131"); or 2-10d box (3"x0.128")Face nail 24.2" subfloor to joist or girder 2-16d common (312"x0.162")Face nail 25.2" planks (plank & beam - floor & roof)2-16d common (312"x0.162")Each bearing, face nail 26.Built-up girders & beams, 2" lumber layers 20d common (4"x0.192") 32"o/c, face nail at top & btm staggered on opposite sides 10d box (3"x0.128") 24"o/c, face nail at top & btm staggered on opposite sides And: 2-20d common (4"x0.192"); or 3-10d box (3"x0.128") Ends at each splice, face nail 27.Ledger strip supporting joists or rafters 3-16d common (312"x0.162"); or 4-10d box (3"x0.128") Each joist or rafter, face nail 28.Joist to band joist or rim joist 3-16d common (312"x0.162"); or 4-10d box (3"x0.128")End nail 29.Bridging or blk'g to joist, rafter or truss 2-8d common (212"x0.131"); or 2-10d box (3"x0.128")Each end, toenail Notes: 1. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the ceiling joist is fastened to the top plate in accordance with this schedule, the number of toe nails in the rafter shall be permitted to be reduced by one nail. 2. Refer to the Design Criteria section on this page for roof and floor sheathing nailing schedule 3. Refer to the Shear Wall Schedule on this page for nailing requirements at wood structural panels DESIGN WIND SPEED, V 95 mph EXPOSURE B RISK CATEGORY II SN1 N/A 10/15/24 GE N E R A L N O T E S Cl i e n t : Ar c h i t e c t : RESTRICTIVE NOTICE THESE DRAWINGS ARE THE SOLE PROPERTY OF JJS STRUCTURAL, INC. AND MAY NOT BE REPRODUCED WITHOUT THE WRITTEN CONSENT OF AN OFFICER OF OUR FIRM. THE PLANS ARE ONLY TO BE USED FOR THIS SPECIFIC PROJECT AND ARE NOT APPLICABLE TO ANY OTHER STRUCTURE. 9 7 5 1 O l y m p i c D r i v e H u n t i n g t o n B e a c h , C A 9 2 6 4 6 7 1 4 -4 9 6 -6 7 7 2 JOB NO.: ISSUE DATE: SCALE: SHEET NO. 24051 RA I L I N G U P G R A D E 10 0 0 W M a c A r t h u r , S a n t a A n a , C A 9 2 7 0 7 Fo w e r s A r c h i t e c t s , I n c . Fo w e r s A r c h i t e c t s , I n c . STATE OF CALIFORNIA JASON SK UDLARSKINo. C67712 Exp. 06/30/25 CIV IL REGISTERED PROFESSIONAL ENGINEER REVISIONS DATE 1 PLAN CHECK 01/13/25 1000 W MacArthur Blvd Unit# 721/23/2025 REBAR LAP/BENDS D0 BEND R= 5(d) FOR #14 THRU #18 LAP SPLICE STIRRUP 6(d ) M I N . TIE OR HOOK OR 4 " M I N . DI M E N S I O N DE T A I L I N G OR 3 " M I N . ALL BENDS SHALL BE MADE COLD ALT. 135° BENDS PUT CROSSTIE W/ EACH STIRRUP D= 4(d) FOR #3 THRU #5 D= 6(d) FOR #6 THRU #8OR 3 " M I N . 12 ( d ) F O R # 6 T H R U # 8 DI M E N S I O N DE T A I L I N G NOTE: CROSSTIE WIRE TIE END D D 48(d) * 90° BEND 8(d) R R= 4(d) FOR #9 THRU #11 R= 3(d) FOR #3 THRU #8 2 1/2" MIN.8(d) 180° BEND R12 " 4(d) OR 6(d ) M I N . 4" M I N . O R 6(d ) * INCREASE LENGTH BY 30% FOR TOP BARS (HORIZONTAL BARS SO PLACED THAT MORE THAN 12" OF FRESH CONC. IS CAST IN THE MEMBER BELOW, EXCLUDE WALLS) 1. 2. 1 2 48 7 6 5913 1014 1115 1216 3TYPICAL DIAPHRAGM FRAMING 16" min. 1. @ ALL EDGES. 2.ROOF OR FLOOR SHEATHING. 24" MIN. UNLESS FULLY BLOCKED ROOF OR FLOOR FRM'G MEMBERS. CONT. PANEL EDGE. ADD 2x FLAT BLK'G & E.N. WHEN BLOCKED DIAPHRAGM IS SPECIFIED. DIAPHRAGM BOUNDARY w/ B.N. PER PLAN. DISCONTINUOUS PANEL EDGE w/ E.N. PER PLAN. FIELD NAILING, F.N., PER PLAN. 1/8" GAP, U.N.O. DIRECTION OF FACE GRAIN, PERPENDICULAR TO SUPPORTS. 3. 4. 5. 6. 7. 8. 9. 4 5 321 7 6 98 NOTES: a.STAGGER JOINTS AS SHOWN. b.NAILS SHALL BE DRIVEN TIGHT, BUT NOT FRACTURE THE SURFACE OF THE SHT'G. c.SEE GENERAL NOTES FOR SHT'G TYPE, THICKNESS, RATING AND NAIL SCHEDULE. d.PROVIDE MIN. 3/8" EDGE DISTANCE AT FRAMING MEMBER & 5/16" TO EDGE OF DIAPHRAGM. e.ALL DIAPHRAGM BOUNDARIES SHALL BE FULLY SUPPORTED BY FRAMING MEMBERS w/ B. N. f.T&G EDGE TO BE LOCATED AT CONT. PANEL JOINT. g.MAX. UNSUPPORTED SHT'G LENGTH IS 24". PROVIDE ADEQUATE FRAMING MEMBERS TO LIMIT SPAN. TYPICAL JOIST HEAD OUT 1 2 32" MAX 32 " MA X 1 3 1.TYPICAL ROOF OR FLOOR JOIST 2.DOUBLE JOIST AT HEAD OUT, TYP. 3.SIMPSON 'HU' HANGER, TYP.2 NOTCHING / BORING - SAWN JOISTS 1 NOTCHING / BORING - STUDS 1 TYP. POST TO BEAM CONNECTION 1.SIMPSON MSTI36 OR ST6224. 2.BEAM PER PLAN. 3.(2) 2X TOP PLATE. 4. SILL PLATE.6. POST PER PLAN. SIMPSON 'A35' AT TOP & BOTT. 5. 7.POST OR MULT. STUD. 8.(3) 16d EA. SIDE. 9.2X STUDS. 2 3 5 4 46 8 7 9 2 EQ.EQ. 1 EQ.EQ. 8 7 9 2 1 TYPICAL STUD WALL OPENING DOUBLE TOP PLATE 2X FULL HEIGHT STUDS AT 16"o/c 2X CRIPPLE STUDS AT 16"o/c HEADER, PER PLAN FULL HEIGHT KING STUD, EACH SIDE W/ (4) 16d NAILS TO HEADER 2X TRIMMER, U.N.O. ON PLANS 2X WINDOW SILL, WHERE OCCURS LOCATE 2X CRIPPLE STUD BELOW WINDOW SILL AND ABOVE ENDS OF HEADER 2X SILL PLATE 1. 2. 3. 4. 5. 6. 7. 8. 9. 12 3 3 4 5 5 6 6 7 8 8 9 ALT. STRAP W/ 16d SINKER STRAP SPLICE NO. OF 16d SINKER MIN. PLATE LAP ST6224ST22 ST6236 MST48 10 4 FT 16 4 FT A B 24 6 FT C D 36 8 FT E NAIL SPLICE 48 8 FT 1.16d SINKER NAILS AT 8"o/c. MIN. (8) NAILS EACH SIDE OF SPLICE, U.N.O. AND PER TABLE BELOW 2.TYPICAL WALL STUDS AT 16"o/c 3.LOCATE STUD UNDER SPLICE OR PROVIDE 2X BLK'G ATTACHED TO ADJACENT STUDS W/ (3) 16d's EACH SIDE 4.NUMBER OF NAILS SPECIFIED BETWEEN SPLICING POINTS PER TABLE BELOW 5.SIMPSON STRAP PER TABLE BELOW 6.ALTERNATE LOCATION OF STRAP 7.CONT. LOWER PLATE AT WALL NOTES: a.FULLY NAIL STRAP W/ 16d SINKER OR 10d COMMON NAILS b.NAILS SHALL BE STAGGERED AND AT LEAST 2 1/4" APART MST60 EQ EQ 4 3 3 2 3 3 2 5 6 1 WALL / FOOTING INTERSECTION 1 1.REINFORCING MAY BE CONTINUOUS OR ADD BARS OF THE SAME SIZE & SPACING AS THE WALL / FOOTING REINFORCING L = 30 BAR DIAMETERS (CONCRETE) L = 40 BAR DIAMETERS (MASONRY) SINGLE LAYER INTERSECTION DOUBLE LAYER INTERSECTION SINGLE LAYER CORNER DOUBLE LAYER CORNER L L L L L L L L 1 1 1 NON-BEARING WALL 3/4" GAP BETWEEN BTM CHORD OR JOIST & 1x TOP PLATE 1. 2. 3. 4. 5. 1 3 JOIST OR TRUSS BTM CHORD SIMPSON 'STC' AT EA, CONNECTION 1x OVER 2x PLATE, TYPICAL AT NON- BEARING WALLS. 2x BLOCKING AT 24"o/c w/ 16d NAIL OR 24"o/c, MAX AT EACH END 1 2 4 4 5 PARALLEL PERPENDICULAR 2 BOTTOM OF WALL 6 2x SILL PLATE w/ 16d COMMON NAILS AT 16"o/c OR 16d BOX NAILS 6. SHEET SN1 AT SLAB CONDITION. AT 12"o/c TO JOIST OR BLK'G BLW. USE SHOT PINS PER NOTES ON 17 18 19 20 SN2 N/A 10/15/24 TY P I C A L DE T A I L S Cl i e n t : Ar c h i t e c t : RESTRICTIVE NOTICE THESE DRAWINGS ARE THE SOLE PROPERTY OF JJS STRUCTURAL, INC. AND MAY NOT BE REPRODUCED WITHOUT THE WRITTEN CONSENT OF AN OFFICER OF OUR FIRM. THE PLANS ARE ONLY TO BE USED FOR THIS SPECIFIC PROJECT AND ARE NOT APPLICABLE TO ANY OTHER STRUCTURE. 9 7 5 1 O l y m p i c D r i v e H u n t i n g t o n B e a c h , C A 9 2 6 4 6 7 1 4 -4 9 6 -6 7 7 2 JOB NO.: ISSUE DATE: SCALE: SHEET NO. 24051 RA I L I N G U P G R A D E 10 0 0 W M a c A r t h u r , S a n t a A n a , C A 9 2 7 0 7 Fo w e r s A r c h i t e c t s , I n c . Fo w e r s A r c h i t e c t s , I n c . STATE OF CALIFORNIA JASON SK UDLARSKINo. C67712 Exp. 06/30/25 CIV IL REGISTERED PROFESSIONAL ENGINEER REVISIONS DATE 1 PLAN CHECK 01/13/25 1000 W MacArthur Blvd Unit# 721/23/2025 X XX # X X X X 1 SYMBOLS SOLID BLOCKING KEY NOTES DIRECTION OF ROOF JOISTS DIRECTION OF CEILING JOISTS DIRECTION OF FLOOR JOISTS DIRECTION OF DECK JOISTS DETAIL NUMBER DETAIL SHEET NUMBER KEY NOTE NUMBER BEAM NUMBER, REFER TO STRUCTURAL CALCS FULLY NAILED SIMPSON 'HU' OR 'HUC' HANGER FRAMING NOTES [#] 1.REFER TO GENERAL NOTES ON SHEET SN-1 FOR ADDITIONAL INFORMATION. 2.ALL BEAM SHOWN ARE DROPPED, U.N.O. 3."LSL" BEAMS MUST HAVE THE FOLLOWING MINIMUM PROPERTIES: Fb = 2325 psi Fv = 310 psi E = 1.55x10⁶ psi (1.55E) 4."PSL" BEAMS MUST HAVE THE FOLLOWING MINIMUM PROPERTIES: Fb = 2900 psi Fv = 290 psi E = 2.2x10⁶ psi (2.2E) 5.ALL TOP PLATES SHALL BE SPLICED W/ AT LEAST (10) 16d SINKER NAILS SPACED NO MORE THAN 8"O.C. APART, U.N.O. AN EQUAL AMOUNT OF NAILS SHALL BE PLACED ON EA. SIDE OF THE SPLICE. REFER TO DETAIL 7/SN2. 6.ROOF SHEATHING SPECIFICATIONS: 7.FLOOR SHEATHING SPECIFICATIONS: 8.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX 9.PLYWOOD ROOF PANELS SHALL BE BONDED WITH INTERMEDIATE OR EXTERIOR GLUE WHERE EXPOSED TO THE WEATHER 10.IF PRE-FABRICATED ROOF TRUSSES ARE PRESENT ON THE PROJECT, THEY MUST BE PROTECTED IN PLACE. DO NOT CUT ANY MEMBERS OR MODIFY IN ANY WAY. IF MODIFICATION IS REQUIRED, PLEASE NOTIFY OUR OFFICE IMMEDIATELY. A TRUSS ENGINEER WILL NEED TO BE CONSULTED TO PROVIDE REPAIR RECOMMENDATIONS. 15/32" APA RATED SHEATHING, EXPOSURE 1 WITH A MIN. PANEL INDEX OF 32/16 BOUNDARY NAILING (B.N.)8d COMMON NAILS AT 6"o/c EDGE NAILING (E.N.)8d COMMON NAILS AT 6"o/c FIELD NAILING (F.N.)8d COMMON NAILS AT 12"o/c 23/32" APA RATED STURD-I-FLOOR, T&G, EXPOSURE 1 WITH A MIN. SPAN RATING OF 24". PLYWOOD MUST CONFORM WITH DOC PS1 OR PS2. BOUNDARY NAILING (B.N.)10d COMMON NAILS AT 6"o/c EDGE NAILING (E.N.)10d COMMON NAILS AT 6"o/c FIELD NAILING (F.N.)10d COMMON NAILS AT 12"o/c USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING WITH ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH THE MFR. RECOMMENDATIONS. UP (E ) 6 x 6 1 S1 6x 6 (E) 6x10(E) 6x10 (E) 6x10 (E) HDR (E) HDR (E) DROP BM (E) HDR (E) HDR (E ) 4 x 6 R . J . (E ) 4 x 6 R . J . (E ) 4 x 6 R . J . (E ) 4 x 6 R . J . (E ) 4 x 6 R . J . (E ) 4 x 6 R . J . (E ) 4 x 6 R . J . (E ) 6 x 6 (E ) 6 x 6 UP (E) 6x10(E) 6x10(E) 6x10 (E) 6x10 (E) 6x10 (E) HDR (E ) 4 x 6 D . J . (E ) 6 x 6 w/ C C (E ) 6 x 6 w/ C C (E ) 6 x 6 w/ C C 2 S1 6x 6 CC 3 S1 4 S1 3 S1 (E) HDR (E) DROP BM (E) HDR (E) HDR (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . (E ) 4 x 6 D . J . (N ) 4 x 6 D . J . TYP @ (N) JOISTS TYP @ (N) JOISTS TYP @ (N) JOISTS 5 S1 TYP 1 1 2 3 4 POST TO BEAM CONNECTION 1. 2. 3. 4. 1 2 33 4 BEAM, PER PLAN POST, PER PLAN BEAM / POST CENTERLINE SIMPSON '1212HT' EACH FACE w/ (6) 5/8"Ø THRU BOLTS POST-TO-BEAM CONNECTION 2 3 1. 2. 3. 4. BEAM, PER PLAN SIMPSON 'CC' w/ (6) 5/8"Ø THRU POST, PER PLAN DECK JOISTS, PER PLAN5 5.WOOD DECKING BOLTS 3 4 1 6 6.SIMPSON 'ACH6Z' GUARDRAIL SECTION 3S1 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 42 " 13 4" 1" 312" 1" 2" 13 4" 123 4 5 67 11 9 10 2x4 TOP RAIL w/ #10x3" WOOD SCREWS AT 12"o/c, TO 2x6 #10x3" WOOD SCREW TO THE TOP OF EACH BALUSTER 2x6 TOP RAIL w/ (2) 1/4"x3 1/2" SDS SCREWS TO EACH 2x6 POST 2-2x6 POSTS AT EACH 4x6 JOIST 2x2 BALUSTERS SPACED PER ARCH'L PLANS NEW 4x6 DECK JOISTS, PER PLAN. STITCH TO EX'G JOISTS w/ 1/4"x6" EX'G DROP BEAM EX'G DECKING POST BEYOND, PER PLAN (2) 1/2"Ø THRU BOLTS w/ STD. CUT WASHERS 11. 8 #10x3" WOOD SCREW FROM EACH BALUSTER INTO EX'G DECKING 212"NOTES: - ALL EX'G WOOD TO REMAIN IS ASSUMED TO BE IN EXCELLENT CONDITION AND CAPABLE OF CARRYING THE SPECIFIED CONNECTIONS SDS SCREWS AT 12"o/c, STAGGERED GUARDRAIL SECTION 4S1 1. 2. 3. 4. 5. 6. 7. 8. 9. 42 " 13 4" 1" 312" 1" 2" 13 4" 3 4 5 67 9 2 2x4 TOP RAIL w/ #10x3" WOOD SCREWS AT 12"o/c, TO 2x6 2x6 TOP RAIL w/ (2) 1/4"x3 1/2" SDS SCREWS TO EACH 2x6 POST 2-2x6 POSTS AT EACH 4x6 JOIST 1x6 BALUSTERS SPACED PER ARCH'L PLANS. PROVIDE (2) #10x2" EX'G DROP BEAM EX'G DECKING POST BEYOND, PER PLAN (2) 1/2"Ø THRU BOLTS w/ STD. CUT WASHERS 8 SCREWS, TOP & BOTTOM NOTES: - ALL EX'G WOOD TO REMAIN IS ASSUMED TO BE IN EXCELLENT CONDITION AND CAPABLE OF CARRYING THE SPECIFIED CONNECTIONS 212" 1 NEW 4x6 DECK JOISTS, PER PLAN. STITCH TO EX'G JOISTS w/ 1/4"x6" SDS SCREWS AT 12"o/c, STAGGERED 1 1 51DECK SECTION 5S1 1. 2. 3. 4. 4 9 EX'G STUD WALL EX'G DROP BEAM, AS OCCURS EX'G FLOOR FRAMING NOTES: - ALL EX'G WOOD TO REMAIN IS ASSUMED TO BE IN EXCELLENT CONDITION AND CAPABLE OF CARRYING THE SPECIFIED CONNECTIONS NEW 4x6 DECK JOISTS, PER PLAN. STITCH TO EX'G JOISTS w/ 1/4"x6" SDS SCREWS AT 12"o/c, STAGGERED 1 1 3 2 5. 6. NOTCH EX'G BLK'G FOR NEW DECK JOIST SIMPSON 'H3' JOIST TO TOP PLATE / DROP BEAM 5 6 S-1 1/4" = 1'-0" 10/14/24 DE C K A N D R O O F FR A M I N G P L A N S ROOF FRAMING PLAN Cl i e n t : Ar c h i t e c t : RESTRICTIVE NOTICE THESE DRAWINGS ARE THE SOLE PROPERTY OF JJS STRUCTURAL, INC. AND MAY NOT BE REPRODUCED WITHOUT THE WRITTEN CONSENT OF AN OFFICER OF OUR FIRM. THE PLANS ARE ONLY TO BE USED FOR THIS SPECIFIC PROJECT AND ARE NOT APPLICABLE TO ANY OTHER STRUCTURE. 9 7 5 1 O l y m p i c D r i v e H u n t i n g t o n B e a c h , C A 9 2 6 4 6 7 1 4 -4 9 6 -6 7 7 2 JOB NO.: ISSUE DATE: SCALE: SHEET NO. 24051 RA I L I N G U P G R A D E 10 0 0 W M a c A r t h u r , S a n t a A n a , C A 9 2 7 0 7 Fo w e r s A r c h i t e c t s , I n c . Fo w e r s A r c h i t e c t s , I n c . STATE OF CALIFORNIA JASON SK UDLARSKINo. C67712 Exp. 06/30/25 CIV IL REGISTERED PROFESSIONAL ENGINEER REVISIONS DATE 1 PLAN CHECK 01/13/25 DECK FRAMING PLAN 1000 W MacArthur Blvd Unit# 721/23/2025 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1000 W MacArthur Blvd Unit# 721/23/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1000 W MacArthur Blvd Unit# 721/23/2025 STRUCTURAL CALCULATIONS RAILING UPGRADE 1000 West MacArthur Blvd. Santa Ana, CA 92707 Client: Fowers Architects, Inc. Job Number: 24051 October 15, 2024 9 7 5 1 O L Y M P I C D R I V E H U N T I N G T O N B E A C H , C A 9 2 6 4 6 1000 W MacArthur Blvd Unit# 721/23/2025 Design Loads Job Number:24051 Name:MacArthur Rails Roof Framing Pitch:4.0 : 12 Slope Factor: 1.054 DL (psf)x Factor Adj. DL Roofing:10.00 1.054 10.54 psf Sheathing:4.63 1.054 4.88 Roof Joists:1.24 1.054 1.30 Sub-total: 16.72 psf Misc.:1.28 DL:18.00 psf LL:20.00 psf TL:38.00 psf Deck Framing DL (psf) Finish: 1.00 psf Sheathing: 4.63 Sheathing: 2.75 Floor Joists: 1.24 Mech'l / Plumb'g: 2.00 Sub-total: 11.61 psf Misc.:1.39 DL:13.00 psf LL:60.00 psf TL:73.00 psf Description Concrete Tile 2x6 Decking Pipe, Ductwork, etc. Description Dex-O-Tex 3/4" OSB (44 pcf) 4x6's @ 48"oc 2x6 Decking 4x6's @ 48"oc Page 2 of 8 1000 W MacArthur Blvd Unit# 721/23/2025 ASCE Hazards Report Address: 1000 W Macarthur Blvd Santa Ana, California 92707 Standard:ASCE/SEI 7-16 Latitude:33.69924 Risk Category:II Longitude:-117.881378 Soil Class:D - Default (see Section 11.4.3) Elevation:33.55876461718752 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Oct 15 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Tue Oct 15 2024 Page 3 of 8 1000 W MacArthur Blvd Unit# 721/23/2025 SS : 1.282 S1 : 0.46 F a : 1.2 F v : N/A SMS : 1.538 SM1 : N/A SDS : 1.025 SD1 : N/A T L : 8 PGA : 0.547 PGA M : 0.657 F PGA : 1.2 Ie : 1 C v : 1.356 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Tue Oct 15 2024 Page 2 of 3https://ascehazardtool.org/Tue Oct 15 2024 Page 4 of 8 1000 W MacArthur Blvd Unit# 721/23/2025 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Tue Oct 15 2024 Page 5 of 8 1000 W MacArthur Blvd Unit# 721/23/2025 Wood Column LIC# : KW-06016311, Build:20.24.10.03 JJS STRUCTURAL (c) ENERCALC, LLC 1982-2024 DESCRIPTION:GUARDRAIL POSTS Project File: 24051 Calcs.ec6 Project Title:RAILING UPGRADE Engineer: Project ID:24051 Project Descr:GUARDRAIL REPLACEMENT .Code References Calculations per NDS 2018, IBC 2021, SDPWS 2021 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 2-2x6Analysis Method : 4Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top Free, Bottom Fixed Wood Species Douglas Fir-Larch Wood Grade No.2 Fb + 900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb - Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf : Built-up columns 1.0 Exact Width 3.0 in Exact Depth 5.50 in Area 16.50 in^2 Ix 41.594 in^4 Iy 12.375 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi No Minimum Basic ABOUT Y-Y Axis: Luy = 4 ft, Ky = 1.20 ABOUT X-X Axis: Lux = 4 ft, Kx = 2.1 Column Buckling Condition: .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 14.305 lbs * Dead Load Factor AXIAL LOADS . . . TOP RAIL: Axial Load at 4.0 ft, D = 0.050 k BENDING LOADS . . . RAIL LOAD: Lat. Point Load at 4.0 ft creating Mx-x, L = 0.250 k .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.6898 Location of max.above base 0.0 ft Applied Axial 0.06431 k Applied Mx -1.0 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 34.091 psi 180.0Allowable Shear psi 0.1263 : 1 Bending Compression Tension Location of max.above base 4.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0 k Bottom along Y-Y 0.250 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.1378 in at 4.0 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 952.52 psi Other Factors used to calculate allowable stresses . . . for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear Ratios CDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results D Only 0.900 PASS PASS0.0 0.0 4.0 ft0.680 ft0.004291 +D+L 1.000 PASS PASS0.0 0.1263 4.0 ft0.641 ft0.6898 +D+0.750L 1.250 PASS PASS0.0 0.07576 4.0 ft0.557 ft0.4159 +0.60D 1.600 PASS PASS0.0 0.0 4.0 ft0.464 ft0.002121 . k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.064 Page 6 of 8 1000 W MacArthur Blvd Unit# 721/23/2025 Wood Column LIC# : KW-06016311, Build:20.24.10.03 JJS STRUCTURAL (c) ENERCALC, LLC 1982-2024 DESCRIPTION:GUARDRAIL POSTS Project File: 24051 Calcs.ec6 Project Title:RAILING UPGRADE Engineer: Project ID:24051 Project Descr:GUARDRAIL REPLACEMENT k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments +D+L 0.0630.250 0.875 +D+0.750L 0.0630.188 0.656 +0.60D 0.038 L Only 0.250 0.875 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftft inin 0.000 +D+L 0.0000 0.092 3.500ftft inin 0.000 +D+0.750L 0.0000 0.069 3.500ftft inin 0.000 +0.60D 0.0000 0.000 0.000ftft inin 0.000 L Only 0.0000 0.091 3.477ftft inin 0.000 .Sketches Page 7 of 8 1000 W MacArthur Blvd Unit# 721/23/2025 Page 8 of 8 1000 W MacArthur Blvd Unit# 721/23/2025