Loading...
HomeMy WebLinkAbout1334 S Olive St - PlanProject : Project Number: By : Date : UNIRAC 1411 Broadway Blvd, NE Albuquerque, NM 87102 RE: Solar Array Installation at 1334 S Olive St, Santa Ana, CA 92707, USA To Whom it May Concern, CODE REFERENCES: BUILDING CODE: 2019 CALIFORNIA BUILDING CODE 2018 INTERNATIONAL BUILDING CODE ASCE 7-16 SCOPE OF WORK: DESIGN PARAMETERS RISK CATEGORY : DESIGN WIND SPEED :mph WIND EXPOSURE : GROUND SNOW LOAD :psf SEISMIC DESIGN CATEGORY : EXISTING ROOF STRUCTURE ROOF : 2x4 Rafters @ 24" O.C. ROOF MATERIAL : Asphalt Shingle CONNECTION TO ROOF STRUCTURE MOUNTING CONNECTION : Castrejon, Jonathan PE 07-10-2022 Roof structural framing plan has been reviewed for additional loading due to installation of the roof mounted solar PV addition. The structural review that follows, including plans and calculations, only apply to the section of the roof that is directly supporting the solar PV system and its supporting elements. 07 October 2022 Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof per layout plan (1) 5/16" SS LAG BOLT w/ MIN. 2.5" EMBEDMENT INTO (E) 2x FRAMING MEMBER @ MAX. 72" o.c. ALONG RAILS (2) RAILS PER ROW OF PANELS, EVENLY SPACED. PANEL LENGTH PERPENDICULAR TO RAIL NOT TO EXCEED 79.6" II 95 B 0 *null 1334 S Olive St 12/05/22 OBSERVED CONDITIONS: CONCLUSIONS: LIMITATIONS: Praneet R Erusu, P.E. Principal Engineer Erusu Consultants US Inc. The observed roof framing is described below. If field conditions differ, the contractor shall notify the engineer prior to starting construction. The roof framing is supported by 2x4 Rafters @ 24" O.C are spanning between load bearing walls. The maximum allowed span of rafter is 7.5ft, to be verified in field by the contractor. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5). The glass surface of the solar panels allows for a lower slope factor per ASCE 7, resulting in reduced design snow load on the panels. The gravity loads and the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 8.4% for roof 1,2 & 3.6% for roof 3 to 8. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Existing Roof and structural members are assumed to be in good and serviceable condition. The contractor must notify Erusu Consultants US Inc. should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others are allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Erusu Consultants US Inc. assumes no responsibility for improper installation of the solar array. 07 Oct 2022 EXP : 30 Sep 2023 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Address : Site Plan: Castrejon, Jonathan PE 07-10-2022 1334 S Olive St, Santa Ana, CA 92707, USA 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Roof Dead Load(For Roof 1 &2) Roof Slope =: Angle = Roof Live Load Roof Live Load = psf (Refer ASCE 7-16, Table 4.3-1) Roof Live Load with PV Array = psf 2019 CBC, Section 1607.13.5 (Ceiling load and MEP is assumed to be not supported by rafter) 3.07 1/2" Gypsum Ceiling Castrejon, Jonathan PE 07-10-2022 DL = Increase due to Roof Slope Plan Projected Materal Weight (psf) 4.09 1.13 3.07 0.51Insulation0.5 1.02 2.25 1.50 12.55 1/2" Plywood 1.1 1.02 Framing 3 1.02 Asphalt Shingle 4 1.02 2.6 12 12 Material Material Weight (psf) PV Array 3 1.02 2.2 1.02 MEP & Misc.1.5 20 0 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Castrejon, Jonathan PE 07-10-2022 Summary of Gravity Loads Dead Load, D =psf Roof Live Load, Lr =psf Gravity Load Comparision (D + Lr)/Cd =psf (Cd = 0.9 for D, 1.15 for S, 1.25 for Lr) Max Loading =psf Proposed to Current Loading Ratio = Existing With PV Array 12.55 15.62 29.95 17.36 20.00 0.00 Existing With PV Array O.K. Gravity Loading with PV Array is not stressing the current framing system by more that 5% of the original configuration. Per Section 503.3 of 2019 California Existing Building Code the sturcure is allowed to remain unaltered for gravity loading 29.95 17.36 58% < 105% 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Roof Dead Load(For Roof 3 to 8) Roof Slope =: Angle = Roof Live Load Roof Live Load = psf (Refer ASCE 7-16, Table 4.3-1) Roof Live Load with PV Array = psf 2019 CBC, Section 1607.13.5 (Ceiling load and MEP is assumed to be not supported by rafter) 5 12 Plan Projected Materal Weight (psf) Castrejon, Jonathan PE 07-10-2022 23 Material Material Weight (psf) Increase due to Roof Slope Asphalt Shingle 4 1.08 4.33 1/2" Plywood 1.1 1.08 1.19 Framing 3 1.08 3.25 Insulation 0.5 1.08 0.54 PV Array 3 1.08 3.25 1/2" Gypsum Ceiling 2.2 1.08 2.38 MEP & Misc.1.5 1.50 DL =13.20 20 0 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Castrejon, Jonathan PE 07-10-2022 Summary of Gravity Loads Dead Load, D =psf Roof Live Load, Lr =psf Gravity Load Comparision (D + Lr)/Cd =psf (Cd = 0.9 for D, 1.15 for S, 1.25 for Lr) Max Loading =psf Proposed to Current Loading Ratio = 13.20 16.45 Existing With PV Array 20.00 0.00 Existing With PV Array 30.67 18.28 Gravity Loading with PV Array is not stressing the current framing system by more that 5% of the original configuration. Per Section 503.3 of 2019 California Existing Building Code the sturcure is allowed to remain unaltered for gravity loading 30.67 18.28 60% < 105% O.K. 1334 S Olive St 12/05/22 Wood Beam LIC# : KW-06014559, Build:20.22.3.31 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition) (Strength Check) Project File: 2x4 Joist @ 24 O.C.ec6 Project Title: Engineer: Project ID: Printed: 7 OCT 2022, 8:40AM Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 . Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.00810 ksf, Tributary Width = 2.0 ft, (Existing Roof Dead Load) Point Load : D = 0.060, W = 0.3180 k @ 4.0 ft, (Solar Panel Load) Uniform Load : Lr = 0.020, W = 0.0160 ksf, Extent = 0.0 -->> 3.0 ft, Tributary Width = 2.0 ft, (Existing Wind & Roof Live Load) Load for Span Number 2 Uniform Load : D = 0.00810, Lr = 0.020, W = 0.0160 ksf, Tributary Width = 2.0 ft, (Existing Roof Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.919: 1 Load Combination +D+0.60W+H Span # where maximum occurs Span # 1 Location of maximum on span 3.980 ft 65.91 psi= = 2,484.00 psi 2x4 Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.750Lr+0.750L+0.450W+H = = = 288.00 psi== Section used for this span 2x4 Maximum Shear Stress Ratio 0.229 : 1 0.000 ft= = 2,281.73 psi Maximum Deflection 106 >=106 153 Ratio =110 >=109 Max Downward Transient Deflection 0.611 in 147 Ratio =>=106 Max Upward Transient Deflection -0.448 in Ratio = Max Downward Total Deflection 0.585 in Ratio =>=109 Max Upward Total Deflection -0.431 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 2 : Lr Only Span: 2 : W Only Span: 1 : +D+0.60W+H Span: 2 : +D+0.60W+H .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C i C L C C C C F/V m r t d Shear ValuesMax Stress Ratios M CV fb M fv F'b V F'vSegment Length +D+H 0.00 0.00 0.000.00 1.00Length = 7.50 ft 1 0.583 0.164 0.90 1.500 1.15 1.00 1.00 0.21 813.97 1397.25 0.09 162.001.00 26.57 1.00Length = 2.0 ft 2 0.091 0.164 0.90 1.500 1.15 1.00 1.00 0.03 126.96 1397.25 0.03 162.001.00 26.57 1.00+D+L+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.524 0.148 1.00 1.500 1.15 1.00 1.00 0.21 813.97 1552.50 0.09 180.001.00 26.57 1.00Length = 2.0 ft 2 0.082 0.148 1.00 1.500 1.15 1.00 1.00 0.03 126.96 1552.50 0.03 180.001.00 26.57 1.00+D+Lr+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.518 0.198 1.25 1.500 1.15 1.00 1.00 0.26 1,004.79 1940.63 0.16 225.001.00 44.47 1334 S Olive St 12/05/22 Wood Beam LIC# : KW-06014559, Build:20.22.3.31 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition) (Strength Check) Project File: 2x4 Joist @ 24 O.C.ec6 Project Title: Engineer: Project ID: Printed: 7 OCT 2022, 8:40AM Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C i C L C C CCF/V m r td Shear ValuesMax Stress Ratios M CV fb M fv F'b V F'vSegment Length 1.00Length = 2.0 ft 2 0.227 0.198 1.25 1.500 1.15 1.00 1.00 0.11 440.42 1940.63 0.10 225.001.00 44.47 1.00+D+S+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.456 0.128 1.15 1.500 1.15 1.00 1.00 0.21 813.97 1785.38 0.09 207.001.00 26.57 1.00Length = 2.0 ft 2 0.071 0.128 1.15 1.500 1.15 1.00 1.00 0.03 126.96 1785.38 0.03 207.001.00 26.57 1.00+D+0.750Lr+0.750L+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.485 0.174 1.25 1.500 1.15 1.00 1.00 0.24 941.87 1940.63 0.14 225.001.00 39.09 1.00Length = 2.0 ft 2 0.187 0.174 1.25 1.500 1.15 1.00 1.00 0.09 362.06 1940.63 0.08 225.001.00 39.09 1.00+D+0.750L+0.750S+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.456 0.128 1.15 1.500 1.15 1.00 1.00 0.21 813.97 1785.38 0.09 207.001.00 26.57 1.00Length = 2.0 ft 2 0.071 0.128 1.15 1.500 1.15 1.00 1.00 0.03 126.96 1785.38 0.03 207.001.00 26.57 1.00+D+0.60W+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.919 0.210 1.60 1.500 1.15 1.00 1.00 0.58 2,281.73 2484.00 0.21 288.001.00 60.40 1.00Length = 2.0 ft 2 0.112 0.210 1.60 1.500 1.15 1.00 1.00 0.07 277.42 2484.00 0.06 288.001.00 60.40 1.00+D+0.750Lr+0.750L+0.450W+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.821 0.229 1.60 1.500 1.15 1.00 1.00 0.52 2,038.26 2484.00 0.23 288.001.00 65.91 1.00Length = 2.0 ft 2 0.191 0.229 1.60 1.500 1.15 1.00 1.00 0.12 474.91 2484.00 0.10 288.001.00 65.91 1.00+D+0.750L+0.750S+0.450W+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.771 0.180 1.60 1.500 1.15 1.00 1.00 0.49 1,914.79 2484.00 0.18 288.001.00 51.94 1.00Length = 2.0 ft 2 0.097 0.180 1.60 1.500 1.15 1.00 1.00 0.06 239.80 2484.00 0.05 288.001.00 51.94 1.00+0.60D+0.60W+0.60H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.787 0.173 1.60 1.500 1.15 1.00 1.00 0.50 1,956.14 2484.00 0.17 288.001.00 49.77 1.00Length = 2.0 ft 2 0.091 0.173 1.60 1.500 1.15 1.00 1.00 0.06 226.64 2484.00 0.05 288.001.00 49.77 1.00+D+0.70E+0.60H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.328 0.092 1.60 1.500 1.15 1.00 1.00 0.21 813.97 2484.00 0.09 288.001.00 26.57 1.00Length = 2.0 ft 2 0.051 0.092 1.60 1.500 1.15 1.00 1.00 0.03 126.96 2484.00 0.03 288.001.00 26.57 1.00+D+0.750L+0.750S+0.5250E+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.328 0.092 1.60 1.500 1.15 1.00 1.00 0.21 813.97 2484.00 0.09 288.001.00 26.57 1.00Length = 2.0 ft 2 0.051 0.092 1.60 1.500 1.15 1.00 1.00 0.03 126.96 2484.00 0.03 288.001.00 26.57 1.00+0.60D+0.70E+H 1.500 1.15 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 7.50 ft 1 0.197 0.055 1.60 1.500 1.15 1.00 1.00 0.12 488.38 2484.00 0.06 288.001.00 15.94 1.00Length = 2.0 ft 2 0.031 0.055 1.60 1.500 1.15 1.00 1.00 0.02 76.17 2484.00 0.02 288.001.00 15.94 . Location in SpanLoad Combination Max. "-" Defl Location in Span Load Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.6106 3.771 0.0000 0.000 W Only20.0000 3.771 -0.4480 2.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum 0.246 0.333 Overall MINimum 0.217 0.261 +D+H 0.084 0.129 +D+L+H 0.084 0.129 +D+Lr+H 0.170 0.244 +D+S+H 0.084 0.129 +D+0.750Lr+0.750L+H 0.148 0.215 +D+0.750L+0.750S+H 0.084 0.129 +D+0.60W+H 0.214 0.286 +D+0.750Lr+0.750L+0.450W+H 0.246 0.333 +D+0.750L+0.750S+0.450W+H 0.182 0.247 +0.60D+0.60W+0.60H 0.181 0.234 +D+0.70E+0.60H 0.084 0.129 +D+0.750L+0.750S+0.5250E+H 0.084 0.129 +0.60D+0.70E+H 0.051 0.078 D Only 0.084 0.129 Lr Only 0.085 0.115 W Only 0.217 0.261 H Only 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Wind Load Calculation (For Roof 1 & 2) Wind Loads - ASCE 7-16 Chapter 26 & 29 Width of the Building, B = ft (Approximate) V = mph Exposure = Average height of building, z = ft - avg (Approximate) ft (Refer ASCE 7-16, Table 26.10-1) α = Zg = ft (Refer ASCE 7-16, Table 26.11-1) Kh & Kz = 2.01(z/Zg)^(2/α) = Kzt =(Refer ASCE 7-16, Equation 26.8-1) Kd =(Refer ASCE 7-16, Table 26.6.1) Ke =(Refer ASCE 7-16, Table 26.9-1) qh ='.00256 KzKztKdKeV² =psf (Refer ASCE 7-16, Section 26.10-1) Building Classification = Solar Panel Components and Cladding p C&C = qh(GCp)(ϒe)(ϒa) ASCE 7-16 Chaper 29.4.4 Module Length = in Module Width = in Area of Module = ft2 Roof Pitch =: Slope = degrees Gable Roof = ϒe= ϒa=(Refer ASCE 7-16, Figure 29.4-8) Castrejon, Jonathan PE 07-10-2022 1200 zmin = 30 7 1 47.2 1 0.85 11.29 2.6 36.2 95 B 15 0.57 Enclosed 0.8 20.0 79.6 7° < θ ≤ 20° 1.5 12 12 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Castrejon, Jonathan PE 07-10-2022 Zone 1 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Zone 2 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf All Zone Downward External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Maximum Uplift Wind Pressure, p = psf Minimum Downward Wind Pressure ,p = psf Lag Screw / Bolt Connection Check (ASD) Tributary Width = in (Max Spacing of fastners along Rails) Tributary Length = in (Half Panel Length) Tributary Area = ft2 Lag Screw/Bolt Size = Cd =(Refer NDS Table 2.3.2) Embedment = in Grade of Wood = #2 ( or better) G = Capacity = lb/in (Refer NDS Table 12.2A) Number of Screws in Tension = Prying Coefficient = Capacity of Fasteners = lb Demand -2.6 (Measured from top of the framing member to tapered tip of lag screw, embeddment in sheathing and tapered tip of screw is not included ) DF -35.21 -2 -27.09 -35.21 16.0 39.8 19.9 5/16 1.6 2.5 72 0.5 6.8 Uplift (lb) Zone 0.5 266 1 1.4 760 Zone 1 Zone 2 0.55 Pressure ASD (0.6W)(psf) -16.3 -21.1 19.9 420.5 760 DCR 19.9 323.4 760 0.43 Capacity (lb)Tributary Area (ft2) 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Wind Load Calculation (For Roof 3 to 8) Wind Loads - ASCE 7-16 Chapter 26 & 29 Width of the Building, B = ft (Approximate) V = mph Exposure = Average height of building, z = ft - avg (Approximate) ft (Refer ASCE 7-16, Table 26.10-1) α =Zg = ft (Refer ASCE 7-16, Table 26.11-1) Kh & Kz = 2.01(z/Zg)^(2/α) = Kzt =(Refer ASCE 7-16, Equation 26.8-1) Kd =(Refer ASCE 7-16, Table 26.6.1) Ke =(Refer ASCE 7-16, Table 26.9-1) qh ='.00256 KzKztKdKeV² =psf (Refer ASCE 7-16, Section 26.10-1) Building Classification = Solar Panel Components and Cladding p C&C = qh(GCp)(ϒe)(ϒa) ASCE 7-16 Chaper 29.4.4 Module Length = in Module Width = in Area of Module = ft2 Roof Pitch =: Slope = degrees Gable Roof = ϒe= ϒa=(Refer ASCE 7-16, Figure 29.4-8) 95 Castrejon, Jonathan PE 07-10-2022 47.2 B 15 zmin = 30 12 1200 0.57 1 0.85 1 11.29 7 Enclosed 79.6 36.2 20.0 5.0 23 20° < θ ≤ 27° 1.5 0.8 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Castrejon, Jonathan PE 07-10-2022 Zone 1 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Zone 2 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf All Zone Downward External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Maximum Uplift Wind Pressure, p = psf Minimum Downward Wind Pressure ,p = psf Lag Screw / Bolt Connection Check (ASD) Tributary Width = in (Max Spacing of fastners along Rails) Tributary Length = in (Half Panel Length) Tributary Area = ft2 Lag Screw/Bolt Size = Cd =(Refer NDS Table 2.3.2) Embedment = in Grade of Wood = #2 ( or better) G = Capacity = lb/in (Refer NDS Table 12.2A) Number of Screws in Tension = Prying Coefficient = Capacity of Fasteners = lb Demand 16.0 -1.5 -20.32 -2.2 -29.80 0.5 6.8 -29.80 1.4 72 39.8 19.9 5/16 1.6 2.5 (Measured from top of the framing member to tapered tip of lag screw, embeddment in sheathing and tapered tip of screw is not included ) DF 0.5 266 1 760 Zone Pressure ASD (0.6W)(psf) Tributary Area (ft2) Uplift (lb) 0.47 DCR Zone 1 -12.2 19.9 242.6 760 0.32 Capacity (lb) Zone 2 -17.9 19.9 355.8 760 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Seismic Ground Motion Values Castrejon, Jonathan PE 07-10-2022 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Seismic Design Force(For Roof 1 & 2) Seismic Loads - ASCE 7-16 Chapter 13 Seismic Force Component Amplification Factor, ap= (Refer ASCE 7-16, Table 13.6 -1) Overstrength Factor, Ωo =(Refer ASCE 7-16, Table 13.6 -1) Component Importance Factor, Ip= SDS = Average roof height of structure,h = ft z/h = z/h should not exceed 1 Frame Weight Wp = psf Seismic Design Force on Solar framing structure Max Fp =1.6 x SDS x Ip X Wp = psf Min Fp =0.3 x SDS x Ip X Wp = psf Seismic Design Load Fp = psf Vertical Seismic Design Load Fp = psf Seismic Coefficients for Mechanical and Electrical components = Component Response Modification Factor, Rp= 1.50 Castrejon, Jonathan PE 07-10-2022 12 Other mechanical or electrical components. (Refer ASCE 7-16, Table 13.6 -1) Height in structure at point of attachement, z = 15 ft 1.00 1.50 1.03 1.00 F P = ((0.4 x ap x SDS x Wp)/ (Rp / Ip)) x ((1+2(z/h)) =2.53 psf 15 1 2.53 5.06 0.95 3.07 0.63 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Castrejon, Jonathan PE 07-10-2022 Check for Increase in overall seismic loads Array Area = ft2 Number of Arrays = Total Array Area = ft2 Array Load = psf Number of Existing Arrays = Exisitng Area = ft2 Total Array Wt. = lb Total Roof Area = ft2 DL of Roof = psf Total Wt of Roof = lb Increase in Seismic Wt = < 10% Conservativelsy the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less thaan 10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2019 CEBC. 20.0 8 160.08 456.68 3.00 480.25 0 0.00 12.55 5731.6 8.4% 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Seismic Design Force(For Roof 3 to 8) Seismic Loads - ASCE 7-16 Chapter 13 Seismic Force Component Amplification Factor, ap= (Refer ASCE 7-16, Table 13.6 -1) Overstrength Factor, Ωo =(Refer ASCE 7-16, Table 13.6 -1) Component Importance Factor, Ip= SDS = Average roof height of structure,h = ft z/h = z/h should not exceed 1 Frame Weight Wp = psf Seismic Design Force on Solar framing structure Max Fp =1.6 x SDS x Ip X Wp = psf Min Fp =0.3 x SDS x Ip X Wp = psf Seismic Design Load Fp = psf Vertical Seismic Design Load Fp = psf Seismic Coefficients for Mechanical and Electrical components =12 Other mechanical or electrical components. (Refer ASCE 7-16, Table 13.6 -1) 1.50 1.00 Castrejon, Jonathan PE 07-10-2022 Height in structure at point of attachement, z = 15 ft 1.00 Component Response Modification Factor, Rp= 1.50 psf 1.03 15 1 3.07 F P = ((0.4 x ap x SDS x Wp)/ (Rp / Ip)) x ((1+2(z/h)) =2.53 5.06 0.95 2.53 0.63 1334 S Olive St 12/05/22 Project : Project Number: By : Date : Castrejon, Jonathan PE 07-10-2022 Check for Increase in overall seismic loads Array Area = ft2 Number of Arrays = Total Array Area = ft2 Array Load = psf Number of Existing Arrays = Exisitng Area = ft2 Total Array Wt. = lb Total Roof Area = ft2 DL of Roof = psf Total Wt of Roof = lb Increase in Seismic Wt = < 20.0 10% Conservativelsy the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less thaan 10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2019 CEBC. 15 300.16 3.00 0 0.00 900.48 1903.6 13.20 25127 3.6% 1334 S Olive St 12/05/22 COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 1334 S OLIVE ST, SANTA ANA, CA 92707 USA REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-0 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.comSYSTEM SUMMARY:DESIGN CRITERIA:GOVERNING CODES: PROJECT SITE 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTS PV-0 ARRAY LOCATIONS GENERAL NOTES · THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. · REFER TO ELECTRICAL DRAWING PV-5 FOR PANEL DETAILED INFORMATION. · IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. · THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM. · THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR TO PERFORMING THE WORK. · ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES. · DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY. · LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. · LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. · DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION PANEL. · ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE BONDED. ·PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. ·RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE DC DISCONNECT. PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAILS PV-4 BRANCH LAYOUT PV-5 ELECTRICAL LINE DIAGRAM PV-6 ELECTRICAL CALCULATION PV-7 PLACARDS & WARNING LABELS PV-8 ADDITIONAL NOTES PV-9+ EQUIPMENT SPEC SHEETS SHEET INDEX (N) 23 - CANADIAN SOLAR CS1Y-395MS (395W) MODULES (N) 23 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS (N) 02 - JUNCTION BOX (E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) 60A NON FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 4 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA GREEN CODE (CGC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) 2019 CA FIRE CODE TITLE 24 SUPPLEMENT ANY OTHER LOCAL AMENDMENTS 23 MODULES-ROOF MOUNTED - 9.09 kWDC, 8.29 CEC kW AC ROOF TYPE: - ASPHALT SHINGLE NUMBER OF LAYERS: - 01 ROOF FRAME: - 2"X4" RAFTERS @24" O.C. STORY: - ONE STORY SNOW LOAD : - 0 PSF WIND SPEED :- 95 MPH WIND EXPOSURE:- B RISK CATEGORY:- II COORDINATE:- 33.729488, -117.877867 07 Oct 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY Bldg permit #101112627 Elect permit #20177846 Issued on 11/4/22 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-9 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com OPTIMIZER CHART 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-10 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-11 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-12 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-13 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-14 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-15 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-16 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-17 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-18 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 AC D MS P UM CB JB JB 31'-8" 10 ' - 1 " 1' - 6 " 20'-3" ~136.72' ~5 2 . 5 1 ' ~136.71' ~5 2 . 6 5 ' AC D MS P UM CB JB SITE PLAN WITH ROOF PLAN REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-1 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SITE PLAN WITH ROOF PLAN 1 SCALE: 1/16" = 1'-0" NOTE: A. ALL ELECTRICAL EQUIPMENT, INVERTERS, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ SUPPLY OR DEMAND PIPING. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ROOF ACCESS POINT LEGEND UTILITY METER AC DISCONNECT JUNCTION BOX UM ACD JB MSP MAIN SERVICE PANEL GATE FENCE CONDUIT VENT, ATTIC FAN (ROOFOBSTRUCTION) CHIMNEY ENPHASE IQ COMBINER 4CB ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF ROOF ARRAY ROOF TILT AZIMUTH PV AREA (SQ.FT.) NO. OF MODULE #1 12° 0° 80.04 04 #2 12° 180° 80.04 04 #3 23° 270° 60.03 03 #4 23° 90° 80.04 04 #5 23° 180° 40.02 02 #6 23° 90° 60.03 03 #7 23° 180° 20.01 01 #8 23° 0° 40.02 02 ROOF #1 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #2 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #3 (03) CANADIAN SOLAR CS1Y-395MS (395W) MODULES SEE ENLARGE VIEW ROOF #4 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #5 (02) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #6 (03) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #7 (01) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #8 (02) CANADIAN SOLAR CS1Y-395MS (395W) MODULES (E) FENCE (E) TREE (TYP.) (E) GATE (E) STRUCTURE ONE- STORY HOUSE POOL S O L I V E S T EXISTING DRIVEWAY PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E ENLARGE VIEW: (N) 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) (TYP.) (N) JUNCTION BOX (TYP.) 2" SCH 40/80 PVC CONDUIT TRENCH ~3'-0" (E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) 60A NON FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 4 18 " M I N 6" MIN SAND 2" SCH 40/80 PVC CONDUIT TRENCH DETAIL 07 Oct 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-19 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 13 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com SPEC SHEETS 1334 S Olive St 12/05/22 AC D MS P UM CB JB JB 5" 6' - 8 " 1 ' - 6 " 3'-0" 6'-8"8'-6" 3" 6'-8"3'-0" 6'-8" 3" 4' - 1 " 1 0 ' - 0 " 4' - 5 " 3'-6"13'-4" 3'-9" 1 ' - 6 " 6' - 8 " 3' - 0 " 3' - 0 " 6' - 8 " 1 ' - 6 " 3'-0" REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-2 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 3/32" = 1'-0"1 79.6" 36 . 2 " PHOTOVOLTAIC MODULES CANADIAN SOLAR CS1Y-395MS (395W) MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 23 MODULES MODULE TYPE = CANADIAN SOLAR CS1Y-395MS (395W) MODULES MODULE WEIGHT = 52.9 LBS / 24.0 KG. MODULE DIMENSIONS = 79.6"X 36.2" = 20.01 SF UNIT WEIGHT OF ARRAY = 2.64 PSF R324.6.2 - PROVING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA.WHEN THE ARRAYS TAKE LESS THAN 33% WE CAN JUSTIFY AN 18" SETBACK ON BOTH SIDES OF THE RIDGE. WHEN IT TAKES MORE THAN 33% OF THE ROOF AREA WE MUST USE A 3' SETBACKS AT THE RIDGE. TOTAL ROOF AREA: 2360.27 sqft AREA OF ARRAYS: 79.6"X 36.2" ( PANEL DIMENSIONS) 79.6"X 36.2" = 20.01 sqft (PER PANEL) 20.01 sqft panel X 23 panels = 460.24 sqft (TOTAL PANEL AREA) PERCENTAGE OF TOTAL ROOF AREA: (460.24 sqft / 2360.27 sqft)(100)= 19.50% ∴ THE PANELS USE 19.50% OF THE TOTAL ROOF AREA ROOF #4 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 04 80.04 228.34 35.05 #2 04 80.04 228.34 35.05 #3 03 60.03 179.78 33.39 #4 04 80.04 245.05 32.66 #5 02 40.02 240.74 16.62 #6 03 60.03 385.71 15.56 #7 01 20.01 109.30 18.31 #8 02 40.02 240.94 16.61 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 12°0°2"x4" 24" O.C. #2 12°180°2"x4" 24" O.C. #3 23°270°2"x4" 24" O.C. #4 23°90°2"x4" 24" O.C. #5 23°180°2"x4" 24" O.C. #6 23°90°2"x4" 24" O.C. #7 23°180°2"x4" 24" O.C. #8 23°0°2"X4" 24" O.C. · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 13 UNIRAC SM LIGHT RAIL 168" DARK SPLICE 00 BND SPLICE BAR PRO SERIES DRK MID CLAMP 28 UNIVERSAL AF SERIES MID CLAMP END CLAMP 36 UNIVERSAL AF SERIES END CLAMP ATTACHMENT 46 UNIRAC FLASHLOC GROUNDING LUG 09 GROUND LUG LEGEND UTILITY METER AC DISCONNECT JUNCTION BOX UM ACD JB MSP MAIN SERVICE PANEL CONDUIT VENT, ATTIC FAN (ROOFOBSTRUCTION) CHIMNEY ENPHASE IQ COMBINER 4CB RAFTERS ROOF ATTACHMENT 1 8 " M I N 6" MIN SAND 2" SCH 40/80 PVC CONDUIT TRENCH DETAIL ROOF #1 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #2 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #3 (03) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #5 (02) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #6 (03) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #7 (01) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #8 (02) CANADIAN SOLAR CS1Y-395MS (395W) MODULES (E) ASPHALT SHINGLE ROOF (TYP.) (N) (46) UNIRAC FLASHLOC ATTACHMENTS SPACED AT 72" O.C. (N) UNIRAC SM LIGHT RAIL (TYP.) (E) 2"X4" RAFTERS @ 24" O.C. (TYP.) 18" FIR E PATHWAY 18" F IRE P A T H W A Y 18" FIRE PATH W A Y 18" FIR E P A T H W A Y 18" FIRE P ATHW A Y 18" FIRE PATH W A Y 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 18" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 18" FIRE PATHWAY 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 36" FIRE PATHWAY 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E P A T H W A Y (N) 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) (TYP.) (N) JUNCTION BOX (TYP.) 2" SCH 40/80 PVC CONDUIT TRENCH ~3'-0" (E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) 60A NON FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 4 ROOF #1 TILT - 12 AZIMUTH - 0 ROOF #2 TILT - 12 AZIMUTH - 180 ROOF #3 TILT - 23 AZIMUTH - 270 ROOF #4 TILT - 23 AZIMUTH - 90 ROOF #5 TILT - 23 AZIMUTH - 180 ROOF #6 TILT - 23 AZIMUTH - 90 ROOF #7 TILT - 23 AZIMUTH - 180 ROOF #8 TILT - 23 AZIMUTH - 0 RE A R Y A R D S O L I V E S T FR O N T Y A R D 07 Oct 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY NOTE:CONTRACTOR TO VERIFY EXISTING FRAMING AND STRUCTURAL LETTER NOTIFY EOR INCASE OF DISCRIPENCIES 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-3 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com ATTACHMENT DETAIL SS SERRATED FLANGE NUT (N) PV MODULES (N) PV MODULES ENLARGED VIEW FLASHLOC BASE MILL OR DARK SS SERRATED T-BOLT (N) UNIRAC SM LIGHT RAIL 5/16" STAINLESS STEEL LAG BOLT OR 2-1/2" MIN. EMBEDMENT AND SS EPDM WASHER (E)2"x4" RAFTE R S @ 2 4 " O.C. ~5 " 2.5" MIN. EMBEDMENT (E) ASPHALT SHINGLE ROOF (E) ASPHALT SHINGLE ROOF ROOF / DECK MEMBRANE BUILDING STRUCTURE 1. 38 " ~5 " 1 . 3 8 " ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS 07 Oct 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY NOTE TO INSTALLER: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY EOR IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND THE FOLLOWING: 2X4 RAFTERS @24" O.C. WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 7.5 FT. 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-4 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com BRANCH LAYOUT BRANCH LAYOUT SCALE: 3/32" = 1'-0"1 (23) CANADIAN SOLAR CS1Y-395MS (395W) MODULES (23) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS (02) BRANCHES OF 08 MODULES & (01) BRANCH OF 07 MODULES CONNECTED IN PARALLEL PER BRANCH 18" RIDGE & 36" FIRE PATHWAY 79.6" 36 . 2 " PHOTOVOLTAIC SOLAR MODULES CANADIAN SOLAR CS1Y-395MS (395W) ROOF #4 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #1 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #2 (04) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #3 (03) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #5 (02) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #6 (03) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #7 (01) CANADIAN SOLAR CS1Y-395MS (395W) MODULES ROOF #8 (02) CANADIAN SOLAR CS1Y-395MS (395W) MODULES 18" F IRE PATHW A Y 18" FIRE P A T H W A Y 18" FIR E P A T H W A Y 18" FIRE P ATHW A Y 18" F I R E P A THW A Y 18" FIR E P A T H W A Y 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 18" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 18" FIRE PATHWAY 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 36" FIRE PATHWAY 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 36" FIRE PATHWAY 36" FIRE PATHWAY 36 " F I R E P A T H W A Y RE A R Y A R D S O L I V E S T FR O N T Y A R D 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y BRANCH #1 (23) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS BRANCH #2 BRANCH #3 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-5 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com ELECTRICAL LINE DIAGRAM ELECTRICAL LINE DIAGRAM SCALE: NTS1 G (N) AC DISCONNECT 60A NON FUSED, 240 VAC BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 23 CANADIAN SOLAR CS1Y-395MS (395W) MODULES INVERTER 23 ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS JUNCTION BOX 02 600V, 55A MAX, 4 INPUTS, MOUNTED ON ROOF FOR WIRE & CONDUIT TRANSITION COMBINER BOX 1 ENPHASE IQ COMBINER BOX 4 AC DISCONNECT 1 240VAC, 60A NON FUSED AC DISCONNECT, NEMA 3R, UL LISTED UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: SCE 240V SIEMENS (E) 225 A (E) 200 A WEST OVERHEAD INTERCONNECTION 120% RULE - CEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 40A = 240A BUSS RATING x 120% 225A x 120% = 270A CHANGE AS PER YOUR REQUIREMENT SERVICE INFO. 23 MODULES X 1.21A= 27.83 A 27.83A X 1.25 = 34.79 A (3) #8 AWG THWN (1) #8 AWG THWN GND IN 3/4" EMT CONDUIT RUN SYSTEM SIZE:- 23 x 395W = 9.09 kWDC SYSTEM SIZE:- 23 x 290W = 6.67 kWAC SYSTEM SIZE:- (23 x 371.5 x 0.97) / 1000 = 8.29 CEC kW AC (23) CANADIAN SOLAR CS1Y-395MS (395W) MODULES (23) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS (02) BRANCHES OF 08 MODULES & (01) BRANCH OF 07 MODULES CONNECTED IN PARALLEL PER BRANCH EXISTING GROUNDING SYSTEM (N) 40A PV BREAKER 200A 40A (E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (BOTTOM FED) L BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) 08 MICRO-INVERTERS IN BRANCH CIRCUIT #2 08 MICRO-INVERTERS IN BRANCH CIRCUIT #1 G (04) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" EMT CONDUIT RUN 07 MICRO-INVERTERS IN BRANCH CIRCUIT #3 (3) Q-CABLE (1) PV #6 BARE CU GND G (02) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 2" SCH 40/80 PVC CONDUIT TRENCH ~3'-0" (N) JUNCTION BOX #1 (N) JUNCTION BOX #2 ENPHASE ENERGY IQ8PLUS-72-2-US , 240V, MICRO-INVERTERS G IQ-GATEWAY 20A 20A 20A 15A (N) ENPHASE IQ COMBINER BOX 4 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-6 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ELECTRICAL CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #CANADIAN SOLAR CS1Y-395MS (395W) MODULES VMP 43.3 IMP 9.13 VOC 52.1 ISC 9.86 MODULE DIMENSION 79.6"L x 36.2"W x 1.38"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE ENERGY IQ8PLUS-72-2-US NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1.21A AMBIENT TEMPERATURE SPECS WEATHER STATION: TUSTIN MCAF RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT (ABOVE ROOF)7/8" ROOF TOP TEMP 31° CONDUCTOR TEMPERATURE RATE (ON ROOF)90° CONDUCTOR TEMPERATURE RATE (OFF ROOF)75° MODULE TEMPERATURE COEFFICIENT OF Voc -0.28%/°C PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 ELECTRICAL CALCULATION SCALE: NTS1 ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE AC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX #1 TO COMBINER BOX: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER CEC 310.15(B)(3)(c): (7/8"RULE) EXPECTED WIRE TEMP (°C): 31° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.96 # OF CURRENT CARRYING CONDUCTORS: 2 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a): 1.0 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): 1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25 X 08 X 1.21A = 12.10A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC TABLE 310.15(B)(2)(a) TEMP CORR. PER CEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.96 X 1.0 X 40 = 38.4A AC CONDUCTOR AMPACITY CALCULATIONS: FROM COMBINER BOX TO INTERCONNECTION: # OF INVERTERS: 23 EXPECTED WIRE TEMP (°C): 31° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.94 # OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER CEC 310.15(B)(3)(a): 1.0 CIRCUIT CONDUCTOR SIZE: 8 AWG CIRCUIT CONDUCTOR AMPACITY: 50 A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(B): 1.25 X # MICRO-INVERTERS X MAX OUTPUT CURRENT = 1.25 X 23 X 1.21 = 34.79A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER CEC TABLE 310.16: TEMP CORR. PER CEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.94 X 1 X 50= 47A RESULT SHOULD BE GREATER THAN (12.10A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY RESULT SHOULD BE GREATER THAN (34.79A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY AC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX #2 TO COMBINER BOX: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER CEC 310.15(B)(3)(c): (7/8"RULE) EXPECTED WIRE TEMP (°C): 31° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.96 # OF CURRENT CARRYING CONDUCTORS: 4 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a): 0.8 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): 1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25 X 08 X 1.21A = 12.10A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC TABLE 310.15(B)(2)(a) TEMP CORR. PER CEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.96 X 0.8 X 40 = 30.72A RESULT SHOULD BE GREATER THAN (12.10A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-7 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com WARNING LABELS & PLACARD CAUTION ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: MAIN SERVICE PANEL & UTILITY METER, AC DISCONNECT & COMBINER BOX 1334 S OLIVE ST (E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) AC NON FUSED DISCONNECT (N) ENPHASE IQ COMBINER BOX 4 (N) PV MODULES WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE. REQ'D BY & 705.12 (B)(3) APPLY TO: MAIN SERVICE PANEL LOAD CENTER COMBINER BOX INVERTER AT EACH AC DISCONNECTS MEANS [CEC 690.13(B) AND 690.54] AT POINT OF INTERCONNECTION OVERCURRENT DEVICE REQ'D BY CEC 705.12 (B)(2)(3)(B) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 27.83 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: CONDUIT, RACEWAYS, AND J-BOXES (LABELED EVERY 10') (PER CODE: CEC690.31(G)(3) WARNING: PHOTOVOLTAIC POWER SOURCE RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: RAPID SHUTDOWN (PER CODE: CEC 690.56(C)(3) CAUTION PHOTOVALTAIC SYSTEM CIRCUIT IS BACKFED LABEL LOCATION: AT MAIN SERVICE PANE, PULL BOXES [CEC 705.12(B)(3)] AT RAPID SHUTDOWN SYSTEM [CEC 690.56(C)(1)(A)] LABEL LOCATION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. 1334 S Olive St 12/05/22 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-8 PROJECT NAME UR10/04/2022 INITIAL RELEASE CA S T R E J O N , J O N A T H A N 1 3 3 4 S O L I V E S T , SA N T A A N A , C A 9 2 7 0 7 U S A AP N # 0 1 3 0 8 4 2 5 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" ENERGY RENOVATION CENTER 11731 Sterling Avenue, Unit G Riverside, CA 92503 LIC:- 1009326 PH:- 8886040226 pm@energyrenovationcenter.com ADDITIONAL NOTES 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 3. AC/DC SOLAR FED CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, PER CEC690.31(G)(3). 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC. 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, PV WIRING MUST BE SECURED AND PROPERLY MANAGED, NOT IN CONTACT WITH ROOF SURFACE. CEC 110.2 - 110.4 / 300.4. WIRE IN CONDUIT NEEDS TO BE MOUNTED > 3.5 IN ABOVE ROOF SURFACE TO MAINTAIN TEMPERATURE DERATE VALUES. 1334 S Olive St 12/05/22 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1334 S Olive St 12/05/22 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. Yes, Composition Unirac Unirc-315168M 52 46 1 72 460.24 8.8 1334 S Olive St 12/05/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan                                                        1334 S Olive St 12/05/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 8 7 8 X X X X 4 3/4" 3/4"3 Energy Renovation Center 2016 E Randol Mill Rd., #409 Arlington, TX 76011 Castrejon, Jonathan 1334 S Olive Street 8.29kW AC 888-604-0226 CS1Y-395MS IQ8Plus-72-2 Square D 1334 S Olive St 12/05/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram Canadian Solar CS1Y-395MS 9.13 43.3 52.1 9.86 27.83 240 X X 40A X -0.28 395 600 Enphase Energy, Inc. IQ8Plus-72-2-US 240 240 40 -0.28 40 300 1.21 Energy Renovation Center 2016 E Randol Mill Rd., #409 Arlington, TX 76011 888-604-0226 Castrejon, Jonathan 8.29kW AC 1334 S Olive Street 1334 S Olive St 12/05/22 1334 S Olive St 12/05/22 1334 S Olive St 12/05/22