Loading...
HomeMy WebLinkAbout2039 N Victoria Drive #2 - PlanADU NEW CONSTRUCTION COUNTY OF ORANGE PROJECT SCOPE PROPERTY INFORMATION VICINITY MAP COVER SHEET SHEET: NORTH SITE PLAN 1 A101 DATE: SCALE: JOB NUMBER: as noted 9/13/2024 24-1055 # DESCRIPTION DATE STATE OF CALIFORNIA 2039 N VICTORIA DR UNIT #2, SANTA ANA, CA, 92706 HOME OWNER OWNER: MICHAEL & CYNTHIA SITTON PHONE: (714) 654-7201 EMAIL: MICHAEL3761@GMAIL.COM CJSITTON@GMAIL.COM ENGINEER: JRS ENGINEERING & DESIGN 3325 E 4TH STREET LONG BEACH,CA, 90814 PHONE: 652-850-1223 JEFF@JRSENGINEERINGDESIGN.COM 3325 E 4TH STREET LONG BEACH, CA, 90814 JRSENGINEERINGDESIGN.COM 562-850-1223 SHEET LIST SDC INFORMATION CA LICENSE NAME: JEFFREY SCHAEFER DISCIPLINE: CIVIL ENGINEER CA LICENSE NO: C-91734 RENEWAL DATE: Dec 31, 2026 JEFF@JRSENGINEERINGDESIGN.COM 2039 N VICTORIA DR, SANTA ANA, CA, 92706 A101 COVER SHEET A102 SITE PLAN A104 FLOOR PLAN A105 EXTERIOR ELEVATIONS SOIL BEARING CAPACITY SDC SITE CLASS IMPORTANCE FACTOR Ss S1 2000 PSF D D II, STANDARD 1.51 0.52 1. CONSTRUCT A DETACHED 998-SF, 1-BED, 1BATH ACCESSORY DWELLING UNIT (ADU) NOTES APPLICABLE CODES ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS 1.1. 2022 CALIFORNIA BUILDING CODE (CBC) 1.2. 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 1.3. 2022 CALIFORNIA PLUMBING CODE (CPC) 1.4. 2022 CALIFORNIA MECHANICAL CODE (CMC) 1.5. 2022 CALIFORNIA BUILDING CODE (CBC) 1.6. 2022 CALIFORNIA ELECTRICAL CODE (CEC) 1.7. 2022 CALIFORNIA ENERGY CODE (CENC) 1.8. CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) 1.9. CITY OF SANTA ANA MUNICIPAL CODE 1. WORK PERFORMED SHALL COMPLY WITH THE CURRENT APPLICABLE CODES. SEE TABLE: 1.1. THESE GENERAL NOTES UNLESS OTHERWISE NOTED ON PLANS OR SPECIFICATIONS. 1.2. STANDARD SPECIFICATIONS OF A.S.T.M. 1.3. AMENDMENTS BY THE LOCAL JURISDICTION 2. ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS. NOTES AND DIMENSIONS TAKES PRECEDENCE OVER SCALING OF THE DRAWING. EACH CONTRACTOR OR SUB-CONTRACTOR SHALL REPORT TO PROJECT OWNER AND DESIGNER ALL CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF THEIR WORK. 3. TYPICAL DETAILS AND SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO BE USED WHEN CONDITIONS ARE NOT OTHERWISE SHOWN. 4. SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON PROJECT. 5. APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OR ALLOWABLE FAILURE TO COMPLY WITH THE PLANS AND SPECIFICATIONS. ANY DESIGN WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE ENGINEER IN WRITING FOR INTERPRETATION OR CLARIFICATION 6. ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALIFORNIA GREEN BUILDING STANDARDS (CGBS) SECTION 4.504.2 6.1. PAINT, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS 6.2. AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS 6.3. DOCUMENTATION SHALL BE PROVIDED TO VERIFY COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED 6.4. CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS 6.5. 80% OF FLOOR AREA CONTAINING RESILIENT FLOORING SHALL COMPLY WITH VOC EMISSION LIMITS PER THE COLLABORATIVE FOR HIGH-PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOOR SCORE PROGRAM 6.6. PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS 7. PRE-CONSTRUCTION MEETING TO BE SCHEDULED WITH INSPECTION PRIOR TO ANY WORK DONE 8. THE ADU SF / SFD RATIO IS FOR PARK AND REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR SF" OF THE EXISTING RESIDENCE A106 EXTERIOR PERSPECTIVE A108 MEP PLAN S101 FOUNDATION PLAN S102 ROOF FRAMING PLAN S103 WALL FRAMING PLAN S104 STRUCTURAL DETAILS T101 TITLE 24 ENERGY CALCULATIONS T102 CALIFORNIA GREEN MANDATORY MEASURES T103 CALIFORNIA GREEN MANDATORY MEASURES ADDRESS 2039 N VICTORIA DR UNIT #2, SANTA ANA, CA, 92706 CONSTRUCTION TYPE V-B AIN 399-111-12 PROPERTY BOUNDARY COLES NORTH SANTA ANA TR LOT BLK B N 90.02 FT S 187.98 FT E 200 FT W 240 FT TR 181 DESCRIPTION LOT AREA (SF) 18,172 SQ FT ZONING R-1 OCCUPANCY TYPE R3/U STORIES MAIN - 2, ADU - 1 (E) MAIN DWELL 2,996 SF (N) ACCESSORY DWELLING UNIT (ADU) 998 SF (NEW SF) (E) GARAGE 660 SF FLOOR AREA RATIO (FAR) 25.6% ADU-SF / SFD-SF RATIO 998 SF / 2,996 SF = 0.333 (33.3%) FIRE SPRINKLERS IN MAIN? NONE EXISTING METHANE MITIGATION ZONE NO LIQUEFACTION ZONE NO FEMA FLOOD ZONE ZONE X (LOW RISK FLOOD ZONE) ADU <0.5 MILES OF PUBLIC TRANSIT. NO PARKING REQUIRED 2039 N VICTORIA DR UNIT #2 A107 INTERIOR PERSPECTIVE A109 BUILDING SECTIONS A110 CABINETRY ELEVATIONS A111 EXISTING PRIMARY DWELLING FLOOR PLAN A112 EXISTING PRIMARY DWELLING EXTERIOR ELEVATIONS A103 DRAINAGE PLAN S105 STRUCTURAL DETAILS T104 TITLE 24 SFR MANDATORY MEASURES Bldg #101122463 APPROVALS: PLNG - C. Santana BLDG - CSG POLICE - B. Martin PUBLIC WORKS - B. Sarlak 2039 N Victoria Drive #24/28/2025 GENERAL INFORMATION 1. WORK PERFORMED SHALL COMPLY WITH THE CURRENT APPLICABLE CODES. SEE TABLE: 1.1. THESE GENERAL NOTES UNLESS OTHERWISE NOTED ON PLANS OR SPECIFICATIONS. 1.2. STANDARD SPECIFICATIONS OF A.S.T.M. 1.3. AMENDMENTS BY THE LOCAL JURISDICTION 2. ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS. NOTES AND DIMENSIONS TAKES PRECEDENCE OVER SCALING OF THE DRAWING. EACH CONTRACTOR OR SUB-CONTRACTOR SHALL REPORT TO PROJECT OWNER AND DESIGNER ALL CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF THEIR WORK. 3. TYPICAL DETAILS AND SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO BE USED WHEN CONDITIONS ARE NOT OTHERWISE SHOWN. 4. SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON PROJECT. 5. APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OR ALLOWABLE FAILURE TO COMPLY WITH THE PLANS AND SPECIFICATIONS. ANY DESIGN WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE ENGINEER IN WRITING FOR INTERPRETATION OR CLARIFICATION. PROPERTY INFORMATION SITE WORK 1. FINISH GRADE FROM ANY FOUNDATION FACE SHALL FALL NOT FEWER THAN 6 INCHES WITHIN THE FIRST 10 FEET. IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION SHALL BE SLOPED NOT LESS THAN 2% AWAY FROM THE BUILDING. 2. CONTRACTOR TO VERIFY EXISTING UTILITY LINES BEFORE TRENCHING 3. TOTAL NEW IMPERVIOUS SQUARE FOOTAGE IS LESS THAN 500-SF THEREFORE NO BMPS FOR WATER RUNOOF (I.E. RAIN BARRELS, PLANTER, ETC.) 4. FOUNDATION CUT WILL BE 29.8 CUBIC YARDS. THIS WILL BE RECOMPACTED AND FOUNDATION PLACED OVERTOP. NET CUT/FILL FOR SITE WILL BE <1 CU.FT N SITE PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/8" = 1'-0" A102 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 ADDRESS 2039 N VICTORIA DR UNIT #2, SANTA ANA, CA, 92706 CONSTRUCTION TYPE V-B AIN 399-111-12 PROPERTY BOUNDARY COLES NORTH SANTA ANA TR LOT BLK B N 90.02 FT S 187.98 FT E 200 FT W 240 FT TR 181 DESCRIPTION LOT AREA (SF)18,172 SQ FT ZONING R-1 OCCUPANCY TYPE R3/U STORIES MAIN - 2, ADU - 1 (E) MAIN DWELL 2,996 SF (N) ACCESSORY DWELLING UNIT (ADU) 998 SF (NEW SF) (E) GARAGE 660 SF FLOOR AREA RATIO (FAR)25.6% FIRE SPRINKLERS IN MAIN?NONE EXISTING METHANE MITIGATION ZONE NO LIQUEFACTION ZONE NO FEMA FLOOD ZONE NO PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 200' 90 ' VI C T O R I A D R 8'-9" 7' - 6 " EXISTING MAIN DWELLING (2996 SF) NOT IN PROJECT SCOPE EXISTING GARAGE (660 SF) NOT IN PROJECT SCOPE NEW 998-SF SINGLE-STORY ADU (N) 30,000 BTU CONDENSER (N) 200-AMP PANEL TO SERVICE ADU 4" SEWER LINE BURIED 18" BELOW GRADE 1" WATER LINE BURIED 12" BELOW GRADE (N) WATER METER FOR ADU (E) WATER METER FOR SFD (N) ADU SEWER CLEANOUT 6' 7'-3"39 ' 34'54'-3"67' 17 ' - 6 " 26 ' FEMA FLOOD MAP SITE DRAINAGE FLOW LINES LOCATION OF PREVIOUSLY DEMOLISHED POOL (NO POOL CURRENTLY EXISTS; RE-COMPACTED SOIL FROM FORMER DEMOLITON) SOUTH ROOF EAVES TO HAVE 1-HR FIRE PROTECTION (5 8" TYP X FIBER CEMENT BOARD PER DETAILS 1/S104, 3/S104) EAST ROOF EAVES TO HAVE 1-HR FIRE PROTECTION (5 8" TYP X FIBER CEMENT BOARD PER DETAILS 1/S104, 2/S104) Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU GRADING PERMIT WAIVER REQUEST PCC-20 ISSUED: 7/1/2024 Page 1 of 1 THIS WAIVER SHALLBE COMPLETED BY THE LEGAL PROPERTY OWNER(S) A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Precise grading plans prepared and stamped by a registered professional engineer shall be required to be submitted before or concurrentlywith the architectural plans submittal to the Building Safety Division. Grading Permit Waiver:Residential detached Accessory Dwelling Unit (ADU) projectswith a total building area of 1,200 sq. feet or less may be eligible for a grading permit waiver request if all of the following conditions are met. The property owner(s) shall take full responsibility for the site drainage by signing this waiver request agreement below. In order to qualify for the grading permit waiver, the property owner(s) shall complete all sections, check appropriate boxes, and sign thiswaiver request. A copy of thiscompletedchecklistshall be made partofthe each set of plans. If answering NO to any of the questions, a grading plan andpermit shall be required. ProjectPropertyAddress: Yes No 1.☐☐The project property is NOT located on a FEMA designated flood zone (Zone A or AE). 2.☐ ☐The total amount of soil being cut or filled on this project is less than 50 cubic yards. 3.☐ ☐The site drainage shall be constructed such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 4.☐ ☐The site drainage shall be constructed such that the drainage will not adversely affect the adjoining properties. 5.☐ ☐The project plans includes a site plan that shows site drainagepatterns. Grading Permit Waiver Request I/we arerequesting a waiver from the standard requirements for a precise grading planand permit for our ADU project to be constructedat the project address indicated above. In doing so, I/we accept that the design of the site drainage patterns must adhere to the minimum requirements set forth in the current building codes and the County of Orange Drainage Design Manual. By signing this waiver request: (1) I/we certify that I/we are the legal property owner(s); (2) I/we agree to take full liability for the site drainage; (3) I/we agree that the checked box conditions above are true; and (4) I/we agree to defend, indemnify, and hold harmless the City of Santa Ana, its officials, employees, and agents against anyand all claims for damages and costs arising outof the site drainage at the project property. Owner Name(s): (Print) Owner Signature(s): Date:Phone Number: Notes: 1. The building official reserves the right to require a grading permitbased on site conditions. 2.This grading permit waiver request does not apply to projects in the FEMA Flood Zones. 2039 N Victoria Dr Unit #2, Santa Ana CA 92706 X X X X X Michael Sitton 1/27/2025 714-654-7201 8'X8' CONCRETE PAD FOR FUTURE SPA (N) 100-AMP SUBPANEL TO SERVICE GARAGE/WORKSHOP (E) 200-AMP PANEL TO SERVICE SFD PUBLIC RIGHT-OF-WAY 2039 N Victoria Drive #24/28/2025 N DRAINAGE PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/8" = 1'-0" A103 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 200' 90 ' VI C T O R I A D R 5' EXISTING MAIN DWELLING (2996 SF) NOT IN PROJECT SCOPE EXISTING GARAGE (660 SF) NOT IN PROJECT SCOPE NEW 998-SF SINGLE-STORY ADU3' - 6 " 39 ' 34'57'67' 20 ' 26 ' FEMA FLOOD MAP SITE DRAINAGE FLOW LINES 142' 142'138' 138' STORM WATER POLLUTION PLAN NOTES: 1. IN CASE OF EMERGENCY, CALL: TBD 2. A STAND-BY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON(OCTOBER 1 TO APRIL 30). NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF EMERGENCY DEVICES WHEN RAIN IS IMMINENT. 3. EROSION CONTROL DEVICES SHOWN ON THIS PLAN MAY BE REMOVED WHEN APPROVED BY GRADING INSPECTOR IF THE GRADING IF THE GRADING OPERATIONS HAS PROGRESSED TO THE POINT '/MERE THEY ARE NO LONGER REQUIRED. 4. GRADING AREAS ADJACENT TO THE SLOPES LOCATED AT THE SITE PERIMETER MUST DRAIN AWAY FROM THE TOP OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY 5.ALL SILT AND DEBRIS SHALL BE REMOVED FROM ALL DEVICES WITHIN 24 HOURS OF EACH RAINSTORM AND BE DISPOSED OF PROPERLY 6. A GUARD SHALL BE POSTED ON THE SITE WHENEVER THE DEPTH OF WATER IN ANY DEVICE EXCEEDS 2'. THE DEVICE SHALL BE DRAINED OR PUMPED DRY WITHIN 24 HOURS AFTER EACH RAINSTORM. 7. EXCEPT AS OTHERWISE APPROVED BY THE GRADING INSPECTOR, ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY OR ON WEEKENDS WHEN THE 5 DAY RAIN PROBABILITY EXCEEDS 40%. 8. ALL LOOSE SOILS AND DEBRIS WHICH MAY CREATE A POTENTIAL HAZARD TO OFF SITE PROPERTY SHALL BE REMOVED FROM THE SITE AS DIRECTED BY THE GRADING INSPECTOR. 9. THE PLACEMENT OF ADDITIONAL DEVICES TO REDUCE EROSION DAMAGE WITH IN THE SITE IS LEFT TO THE DISCRETION OF THE FIELD EXAMINER. 10. DESALTING BASINS MAY NOT BE REMOVED OR MADE INOPERABLE BETWEEN NOVEMBER 1 AND APRIL 15 OF THE FOLLOWING YEAR WITHOUT THE APPROVAL OF THE GRADING INSPECTOR. 11. EROSION CONTROL DEVICES ARE TO BE MODIFIED AS NEEDED AS THE PROJECT PROGRESSES AND PLANS OF THESE CHANGES MUST BE SUBMITTED FOR APPROVAL AS REQUIRED. 12. ADD THE FOLLOWING NOTES (OR SIMILAR) TO THE PLANS TO DEFINE THE CURRENT STATE OF CONSTRUCTIONAL CHANGES.CHANGES MUST BE SUBMITTED FOR APPROVAL AS REQUIRED. A. STORM DRAINS AND CATCH BASINS ARE (NOT) CONSTRUCTED B. STREETS ARE (NOT) PAVED, EXCEPT AS NOTED ON THE EROSION CONTROL PLANS C. DRAINAGE DEVICES ARE (NOT) CONSTRUCTED, EXCEPT AS NOTED ON PLANS. 13. STORM WATER POLLUTION CONTROL REQUIREMENTS MUST BE INTEGRATED INTO THE EROSION CONTROL PLANS PER TITLE 62 SECTION 7010 OF THE COUNTY CODE FOR ANY CONSTRUCTION BETWEEN OCTOBER 1 AND APRIL 15. THE FOLLOWING NOTES AND BMPS AS OUTLINED IN, BUT NOT LIMITED TO, THE BEST MANAGEMENT PRACTICE HANDBOOK, CALIFORNIA STORM WATER QUALITY TASK FORCE, SACRAMENTO CALIFORNIA 1993. OR THE LATEST REVISED EDITION MAY APPLY DURING THE CONSTRUCTION OF THIS PROJECT (ADDITION MEASURES MAYBE REQUIRED IF DEEMED APPROPRIATE BY COUNTY INSPECTORS) ATTACHMENT A NOTES: A. EVERY EFFORT SHOULD BE MADE TO ELIMINATE THE DISCHARGE OF NON STORM WATER FROM THE PROJECT SITE AT ALL TIMES B. ERODED SEDIMENTS AND OTHER POLLINATES MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS NATURAL DRAINAGE OR COURSES OR WIND. C. STOCKPILE OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER D. FUELS, OILS SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE W/ THEIR USING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINER ARE TO BE PROTECTED FROM THE WEATHER SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED IN TO THE DRAINAGE SYSTEM. E. EXCESS OR WASTER CONCRETE MAY NOT BE WASHED IN TO THE PUBLIC WAS OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. F.TRASH AND CONSTRUCTION RELATED CONTAMINATION SOUD WASTES MUST BE DEPOSITED IN TO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER & DISPERSAL BY WIND. G. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKER FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM EYING DEPOSITED IN TO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN/ OTHER MEANS. H. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO NO CAUSE EROSION. NOTES: 1. EXCESS AND WASTE CONCRETE SHALL NOT BE WASHED IN TO THE STREET OR INTO A DRAINAGE SYSTEM. 2. FOR WASH OUT OF CONCRETE AND MORTAR PRODUCTS A DESIGNATED CONTAINMENT FACULTY OF SUFFICIENT CAPACITY TO RETAIN LIQUID AND SOLID WASTE SHALL BE PROVIDED ON SITE. 3. SLURRY FROM CONCRETE AND ASPHALT SAW CUTTING SHALL BE VACUUMED OR CONTAINED, DRIED, PICKED UP AND DISPOSED OF PROPERLY. 4. ALL REMOVABLE VERSIONS PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE 5-DAY PROBABILITY FORECASTS. 5. AFTER A RAINSTORM, ALL SILT AND DEBRIS SHALL BE REMOVED FROM STREET. CHECK BERMS AND BASINS. 6. GRADED AREAS ON THE PERMITTED AREA PERIMETER MUST DRAIN AWAY FROM SLOPS AT THE CONCLUSION OF EACH WORKING DAY. DRAINAGE TO BE DIRECTED TOWARD DESILTING FACULTIES. 7. THE PERMITTEE AND CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREA WHERE IMPOUNDED WATER CREATED A HAZARDOUS CONDITION. 8. THE UNDERSIGNED CIVIL ENGINEER SHALL INSPECT EROSION CONTROL WORK AND ENSURE THAT THE WORK IS IN ACCORDANCE WITH THE APPROVED PLANS. 9. AT LEAST 2-LAYERS OF SANDBAGS FILLED WITH SAND ARE PA GRAVEL SHALL BE LAID ALONG THE PERIMETER OF THE PROJECT AREA AND SHOWN DURING CONSTRUCTION. GUTTERS ON ROOF EAVE (SLOPE TO SOUTH) GUTTERS ON ROOF EAVE (SLOPE TO WEST) GUTTERS ON ROOF EAVE (SLOPE TO WEST) GUTTERS ON ROOF EAVE (SLOPE TO SOUTH) 2039 N Victoria Drive #24/28/2025 N FLOOR PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" A104 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 19'-2"13'-7" 39 ' - 0 " 9'-4" 14 ' - 9 " FLOOR PLAN 998 SF 4' - 6 " 33 ' - 3 " 4' - 1 " 4' - 1 " 24 " c l e a r 15"15" 48X22" VANITY WALK-IN CLOSET SHELVING 34" Wide Fridge A B C 1 2 3 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 24X42 SKY FREESTANDING CLOSET 1 2 3 A B C 4X6 BEAM 4X6 BEAM 9'-5" SYMBOL WIDTH HEIGHT QTY TYPE MATERIAL U-FACTOR SHGC DOOR SCHEDULE 1. ALL DOORS AND WINDOWS TO BE APPROVED BY OWNER PRIOR TO INSTALLATION 2. ALL GLAZING WITHIN A DOOR AND WITHIN 24" OF A DOOR SHALL BE TEMPERED AND LABELED AS SUCH 72" 80" 2 FRENCH WOOD SOLID CORE SYMBOL WIDTH HEIGHT QTY TYPE MATERIAL U-FACTOR SHGC WINDOW SCHEDULE 1. ALL DOORS AND WINDOWS TO BE APPROVED BY OWNER PRIOR TO INSTALLATION 2. EGRESS WINDOWS FROM SLEEPING ROOM SHALL HAVE A NET CLEAR OPENING OF 5.7 SF WITH A MINIMUM CLEAR WIDTH OF 20" AND CLEAR HEIGHT OF 24". FINISHED SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE FINISHED FLOOR 3. SKYLIGHTS TO BE MANUFACTURED BY VELUX IN ACCORDANCE WITH UES REPORT #199 OR CONTRACTOR TO PROVIDE EQUIVALENT FOR SUBSTITUTION. SKYLIGHTS AND SLOPED GLAZING SHALL COMPLY WITH SECTION R308.6. 32" 24"5 GLASS / WOOD 0.30 MAX 0.23 MAXA B C 24" 72"6 0.30 MAX 0.23 MAX 24" 42"4 0.30 MAX 0.23 MAX 2 32" 80" 2 N/A N/A TEMPERED GLASS / WOOD 1 1 2 BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 FT. ABOVE THE FLOOR. (R307.2) TEMPERED GLAZING SHALL BE PROVIDED AT HAZARDOUS LOCATIONS AS IDENTIFIED IN CRC R308.4. HAZARDOUS LOCATIONS INCLUDE, BUT ARE NOT LIMITED TO: -GLAZING WITHIN A 24" ARC OF A DOOR EDGE -GLAZING NEAR WET SURFACES (BATHTUBS, SHOWERS, ETC.) WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE AND IS LESS THAN 60" MEASURED HORIZONTALLY IN A STRAIGHT LINE FROM THE WATER'S EDGE OF A BATHTUB OR FROM THE EDGE OF A SHOWER FLOOR NOTES 3 22-IN. X 30-IN. ATTIC ACCESS WITH 30-IN. MINIMUM HEADROOM FOR ATTIC GREATER THAN 30 SF. (R807.1) 4 MINIMUM 180 CFM KITCHEN HOOD FOR ELECTRICAL STOVE. EXHAUST TO EXTERIOR WITH METAL DUCT WORK. A CEILING OR WALL EXHAUST MAY BE USED THAT PROVIDES 5 AIR CHANGES PER HOUR SILL HEIGHT 60" 8" 38" POCKET DOUBLE-HUNG GLASS / WOOD 0.30 MAX 0.23 MAX WOOD SOLID CORE 1 1 2 2 FIXED A A A A A FIXED B B B B B B C C C C 1 3 4 D 24" 42"6 0.38 MAX 0.25 MAXN/A GLASSSKYLIGHT3 D 60 " C A S E D OP E N I N G B-B A108 B-B A108 A-A A108 A-A A108 E E 24" 24"1 0.30 MAX 0.23 MAX56"DOUBLE-HUNG GLASS / WOOD WATER HEATER W/D 3 4' - 0 " 20'-0" 4'-0" 11 ' - 5 " ELEC. 30" 32"X54" SHOWER (1728 SQ. IN). 2X8 REINFORCEMENT INSTALLED ACROSS ALL SHOWER WALLS @ 32" ABOVE GRADE FOR FUTURE GRAB BAR PLACEMENT PER R327.1.1 5 PROVIDE AGING IN PLACE REQUIREMENTS PER CRC R327: -2X8 REINFORCEMENT INSTALLED ACROSS ALL SHOWER WALLS @ 32" ABOVE GRADE FOR FUTURE GRAB BAR PLACEMENT (R327.1.1) -ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES (1219.2 MM) MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR (R327.1.2) -DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. (R327.1.4) (N) 1-1/2" MAX DOOR THRESHOLD (N) 1-1/2" MAX DOOR THRESHOLD LIVING SPACE KITCHEN BATH ROOM BEDROOM 9FT FLAT CLG 9FT FLAT CLG 9FT FLAT CLG 9FT CLG 9FT CLG 9F T C L G 9F T C L G 9F T C L G 9F T C L G 12 F T - 6 I N C L G 12 F T - 6 I N C L G 9F T C L G 24X42 SKY D 24X42 SKY D 24X42 SKY D 24X42 SKY D 24X42 SKY D 2039 N Victoria Drive #24/28/2025 North ElevationWest Elevation East Elevation South Elevation EXTERIOR ELEVATIONS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" A105 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 F.F. 1ST 0' - 0" 1 2 3 TOP ROOF 14' - 0" CLG 1ST 9' - 0" CBA F.F. 1ST 0' - 0" TOP ROOF 14' - 0" CLG 1ST 9' - 0" F.F. 1ST 0' - 0" 123 TOP ROOF 14' - 0" CLG 1ST 9' - 0" C B A F.F. 1ST 0' - 0" TOP ROOF 14' - 0" CLG 1ST 9' - 0" 7 8" STUCCO TO MATCH EXISTING SFD 7 8" STUCCO TO MATCH EXISTING SFDWEEP SCREED PER DETAIL 11/S105 WEEP SCREED PER DETAIL 11/S105 WEEP SCREED PER DETAIL 11/S105 WEEP SCREED PER DETAIL 12/S105 WEEP SCREED PER DETAIL 11/S105 7 8" STUCCO TO MATCH EXISTING SFD 2039 N Victoria Drive #24/28/2025 EXTERIOR PERSPECTIVE DRAWINGS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" A106 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 2039 N Victoria Drive #24/28/2025 INTERIOR PERSPECTIVE DRAWINGS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS A107 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 KITCHEN LOOKING AT OPEN SPACE OPEN SPACE LOOKING AT KITCHEN 2039 N Victoria Drive #24/28/2025 BUILDING SECTION A-A BUILDING SECTION B-B BUILDING SECTIONS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 3/8" = 1'-0" A109 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 123 CBA Thicken perimeter edge of concrete slab to depth of 24" for 12" width. (See Detail 1/S104) 1/2" dia. anchor bolt every 4' o.c. Embed min 7" 2x6 load bearing exterior wall. Insulate with R-19 + R5 Exterior Rigid Foam. A35 shear clip between blocking and top plate every 42" o.c. 7 8" stucco finish over 1 8" air gap and WRB 24X48 SKY 24X48 SKY 24X48 SKY LIVING SPACE KITCHEN BATH ROOM 15-mil vapor barrier beneath new slab 5" concrete slab with #4 rebar spaced at 16" o.c. both directions Capillary break consisting of 4-inch-thick gravel base of 1/2 inch or larger clean aggregate 2x10 roof rafters spaced at 24" o.c. with R-30 insulation installed in cavity. Use DF #2 2x6 roof rafters spaced at 16" o.c. Use DF #2 Min R-30 insulation atop ceiling joists 2x6 ceiling joists spaced at 16" o.c. Use DF #2 4x6 decorative roof rafter left exposed below ceiling 4x12 door/window header Window 5" concrete slab with #4 rebar spaced at 16" o.c. both directions ATTIC Thicken perimeter edge of concrete slab to depth of 24" for 12" width. (See Detail 1/S104) 1/2" dia. anchor bolt every 4' o.c. Embed min 7" 2x6 load bearing exterior wall. Insulate with R-19 + R5 Exterior Rigid Foam. 7 8" stucco finish over 1 8" air gap and WRB T&G Pine ceiling planks 4x12 door/window header Window 5" concrete slab with #4 rebar spaced at 16" o.c. both directions 2x6 roof rafters spaced at 16" o.c. Use DF #2 2x6 ceiling joists spaced at 16" o.c. Use DF #2 ATTIC LIVING SPACEBED Thicken slab to 18" depth / 12" width beneath load-bearing wall (Detail 2/S104) 2x10 roof rafters spaced at 24" o.c. with R-30 insulation installed in cavity. Use DF #2 4x6 decorative roof rafter left exposed below ceiling 5.25"x18" Ridge Beam. Use 2.2E PSLT&G Pine ceiling planks 1/2" Gypsum ceiling board 1/2" Gypsum ceiling board Min R-30 insulation atop ceiling joists Min R-19 insulation between attic roof rafters Min R-19 insulation between attic roof rafters 2039 N Victoria Drive #24/28/2025 CABINETRY ELEVATIONS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 3/4" = 1'-0" A110 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 12'-4" 35"31"34" 66 " 36 " 30 " 36 " 30 " 30 " Stove vent, concealed to resemble cabinetry Soffit height bottom height of 8'-0" above floor 34" Wide Fridge 15" 18" Supply vent for HVAC (duct in attic) Undermount lighting beneath upper cabinets 12'-4" 2' - 8 " ENLARGED KITCHEN FLOOR PLAN 15" Stove vent, concealed to resemble cabinetry 2039 N Victoria Drive #24/28/2025 EXISTING PRIMARY DWELLING FLOOR PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" A111 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 SECOND FLOOR PLAN FIRST FLOOR PLAN (E) LIVING ROOM (E) MASTER BEDROOM (E) BEDROOM (E) SITTING ROOM (E) KITCHEN (E)DINING (E) MASTER BATHROOM (E)MASTER CLOSET (E) BATHROOM 6'-10"21'-0" 18 ' - 9 " 8' - 5 " 14 ' - 1 1 " 15'-5" 12 ' - 8 " 8'-0" (E ) P A N T R Y (E ) C L O S E T (E) FOYER (E) HALLWAY 4'-7"8'-3" (E) HALLWAY 6'-7" NOTE: NO CHANGE TO OCCUR TO PRIMARY DWELLING AS PART OF PROJECT SCOPE. FLOOR PLAN SHOWN FOR REFERENCE ONLY 2039 N Victoria Drive #24/28/2025 EXISTING PRIMARY DWELLING EXTERIOR ELEVATIONS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 3/16" = 1'-0" A112 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 NOTE: NO CHANGE TO OCCUR TO PRIMARY DWELLING AS PART OF PROJECT SCOPE. ELEVATIONS SHOWN FOR REFERENCE ONLY EAST EXTERIOR ELEVATION SOUTH EXTERIOR ELEVATION NORTH EXTERIOR ELEVATION WEST EXTERIOR ELEVATION 2039 N Victoria Drive #24/28/2025 FOUNDATION PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" S101 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 STRUCTURAL ENGINEERING 1. ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS. NOTES AND DIMENSIONS TAKES PRECEDENCE OVER SCALING OF THE DRAWING. EACH CONTRACTOR OR SUB-CONTRACTOR SHALL REPORT TO PROJECT OWNER AND DESIGNER ALL CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF THEIR WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS 2. NO DEVIATIONS FROM STRUCTURAL DETAILS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE STRUCTURAL DESIGN ENGINEER. APPROVAL BY CITY INSPECTOR DOES NOT CONSTITUTE AUTHORITY TO DEVIATE FROM PLANS OR SPECIFICATIONS. 3. STRUCTURAL DESIGN DOES NOT CONSIDER EFFECTS OF MECHANICAL EQUIPMENT. 4. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. STRUCTURAL DESIGN CRITERIA 1. SOIL BEARING CAPACITY EQUALS 2,000 PSF ACCORDING TO GEOLOGICAL SOIL REPORT BY TGR GEOTECHNICAL, INC DATED NOV 8, 2024 2. DESIGN VALUES ARE BASED OFF THE FOLLOWING CRITERIA: 2.1. RISK CATEGORY: II 2.2. GROUND FLOOR LIVE LOAD: 40 PSF 2.3. ROOF LIVE LOAD: 20 PSF 2.4. ROOF DEAD LOAD: 15 PSF (19 PSF WHERE SOLAR PANELS) 2.5. FLOOR LIVE LOAD: 30 PSF (BEDROOM AREA) 2.6. FLOOR LIVE LOAD: 40 PSF (OTHER AREAS) 2.7. FLOOR DEAD LOAD: 10 PSF 2.8. GROUND SNOW LOAD: 0 PSF 2.9. BASIC WIND SPEED: 95 MPH 2.10. EXPOSURE CATEGORY: B 2.11. ENCLOSURE CLASSIFICATION: ENCLOSED 2.12. SEISMIC SITE CLASS: D 2.13. SEISMIC DESIGN CATEGORY: D 2.14. RESPONSE MODIFICATION FACTOR: 6.5 2.15. SEISMIC DESIGN COEFFICIENTS: SDS=1.19, SD1=0.81 FOUNDATION 1. THE MINIMUM RECOMMENDED FOOTING DEPTH IS 24-INCHES BELOW THE LOWEST ADJACENT GRADE. THE MINIMUM RECOMMENDED FOOTING WIDTH IS 18 INCHES FOR CONTINUOUS FOOTING AND TWENTY-FOUR (24) INCHES FOR PAD FOOTINGS. ALL CONTINUOUS FOOTINGS OVERTOP OR NEAR DEMOLISHED POOL (SHADED REGION) TO BE PLACED OVER A MINIMUM OF THREE FEET OF ENGINEERED FILL. ALL UNCERTIFIED PREVIOUSLY PLACED FILL ÐHALL BE REMOVED AND REPLACED AS ENGINEERED FILL ALONG WITH THE MIN 3 FOOT FILL REQUIREMENT UNDER THE FOOTING. 2. PRIOR TO ANY FILL PLACEMENT TGR SHOULD OBSERVE THE EXPOSED SURFACE SOILS. THE SITE SOILS MAY BE RE-USED AS ENGINEERED FILL PROVIDED THEY ARE FREE OF ORGANIC CONTENT AND PARTICLE SIZE GREATER THAN 4-INCHES. ALL PARTICLES GREATER THAN 4-INCHES SHALL BE REMOVED AND DISPOSED OFFSITE. FILL SHALL BE MOISTURE-CONDITIONED TO OPTIMUM MOISTURE CONTENT AND COMPACTED TO A MINIMUM RELATIVE COMPACTION OF 90 PERCENT IN ACCORDANCE WITH ASTM D1557. ANY IMPORT SOILS SHALL BE NON-EXPANSIVE AND APPROVED BY TGR GEOTECHNICAL INC. 3. ANY VEGETATION AND/OR DEMOLITION DEBRIS SHALL BE REMOVED AND HAULED FROM THE PROPOSED GRADING AREAS PRIOR TO THE START OF GRADING OPERATIONS EXISTING VEGETATION SHALL NOT BE MIXED OR DISCED INTO THE SOILS 4. ANY REMOVED SOILS MAY BE REUSED AS COMPACTED FIL ONCE ANY DELETERIOUS MATERIAL OR OVERSIZED MATERIALS (IN EXCESS OF EIGHT INCHES) IS REMOVED. 5. GRADING SHALL EXTEND A MINIMUM OF SEVEN HORIZONTAL FEET OUTSIDE THE EDGES OF FOUNDATIONS OR EQUIDISTANT TO THE DEPTH OF FILL PLACED, WHICHEVER IS GREATER 6. DUE TO ELEVATED MOISTURE LEVELS IN THE SUBSURFACE SOILS, IT IS POSSIBLE THAT WET AND/OR YIELDING SOILS MAY BE ENCOUNTERED DURING SITE GRADING. AERATION OF WET SOILS AND STABILIZATION INCLUDING THE USE OF GEOTEXTILE FABRIC AND GRAVEL MAY BE REQUIRED BASED ON ACTUAL FIELD CONDITIONS DURING SITE GRADING 7. ALL CONCRETE SLABS INCLUDING DRIVEWAY AND HARDSCAPE SHALL BE A MINIMUM OF FIVE INCHES IN THICKNESS REINFORCED WITH A MINIMUM OF NO.4 BARS, SIXTEEN INCHES IN EACH DIRECTION POSITIONED IN THE CENTER OF THE SLAB AND PLACED ON APPROVED SUBGRADE SOILS. THE SUBGRADE MATERIAL SHOULD BE COMPACTED TO A MINIMUM OF NINETY (90) PERCENT OF THE MAXIMUM LABORATORY DRY DENSITY (ASTM D1557) TO A MINIMUM DEPTH OF THREE (3) FEET OR THE BOTTOM OF UNDOCUMENTED FILL (WHICHEVER IS DEEPER). PRIOR TO PLACEMENT OF CONCRETE, THE SUBGRADE SOILS SHOULD BE MOISTENED TO OPTIMUM MOISTURE CONTENT AND VERIFIED BY A TGR GEOTECHNICAL, INC FIELD REPRESENTATIVE. 8. A VAPOR RETARDER (15-MIL MINIMUM THICKNESS) SHOULD BE UTILIZED BENEATH ALL NEW SLABS 9. IN AREAS NOT ADJACENT TO EXISTING STRUCTURES OR PROPERTY LINES, SOILS MAY BE CUT VERTICALLY TO A DEPTH OF APPROXIMATELY FOUR (4) FEET BELOW ADJACENT GRADE. EXCAVATIONS DEEPER THAN 4 FEET SHOULD BE TEMPORARILY SHORED OR SLOPED BACK TO AT LEAST 1H:1V OR FLATTER FOR THE ENTIRE EXCAVATION. THE EXPOSED SLOPE FACE SHOULD BE KEPT MOIST (BUT NOT SATURATED) DURING CONSTRUCTION TO REDUCE LOCAL SLOUGHING. NO SURCHARGE LOADS SHOULD BE PERMITTED WITHIN A HORIZONTAL DISTANCE EQUAL TO THE HEIGHT OF CUT FROM THE TOE OF EXCAVATION UNLESS THE CUT IS PROPERLY SHORED. TEMPORARY EXCAVATION THAT EXTENDS BELOW AN IMAGINARY PLANE INCLINED AT 45 DEGREES FROM THE PROPERTY LINE OR BELOW THE EDGE OF ADJACENT EXISTING FOOTINGS WILL REQUIRE SHORING. 10. ALL GRADING AND OVEREXCAVATION SHALL CONFORM TO THE REQUIREMENTS OF THE SOILS REPORT PREPARED BY TGR GEOTECHNICAL, INC DATED NOV 2024 CONCRETE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF 2,500 PSI WITH TYPE V CEMENT AND MAXIMUM WATER CEMENT RATIO OF .45. NO SPECIAL INSPECTION REQUIRED IF CONCRETE TRUCK MIX TICKET IS PROVIDED. 2. ALL REBAR REINFORCING SHALL BE ASTM A955 GRADE 60 (FY=60 KSI) 34'-0" 39 ' - 0 " 15 ' - 7 " A B C 1 2 3 1 2 3 A B C 2'-8"2'-8"14'-8" 5'4'-5"4'-7" 2' - 8 " 2' - 8 " 10 ' - 3 " 9' - 1 " 9' - 7 " HDU2 HDU5 HDU2 HDU2 HDU5 HDU2 CB46 HDU2 HDU2 HDU2 HDU2 HDU2 2' - 6 " THICKEN PERIMETER EDGE OF CONCRETE SLAB TO DEPTH OF 24" FOR 18" WIDTH. (SEE DETAIL 11/S105) THICKEN PERIMETER EDGE OF CONCRETE SLAB TO DEPTH OF 24" FOR 18" WIDTH. (SEE DETAIL 11/S105) THICKEN SLAB TO 24" DEPTH / 18" WIDTH BENEATH LOAD-BEARING WALL TO CARRY CEILING JOISTS LOAD. (DETAIL 13/S105) 11 S105 11 S105 11 S105 11 S105 12 S105 12 S105 13 S105 14 S105 15 S105 15 S105 LOCATION OF PREVIOUSLY DEMOLISHED POOL (NO POOL CURRENTLY EXISTS; RE-COMPACTED SOIL FROM FORMER DEMOLITION). THIS FILL IS UNSUITABLE FOR SUPPORT OF NEW STRUCTURE OR ENGINEERED FILL ALL CONTINUOUS FOOTINGS OVERTOP OR NEAR DEMOLISHED POOL (SHADED REGION) TO BE PLACED OVER A MINIMUM OF THREE FEET OF ENGINEERED FILL. ALL UNCERTIFIED PREVIOUSLY PLACED FILL ÐHALL BE REMOVED AND REPLACED AS ENGINEERED FILL ALONG WITH THE MIN Ó FOOT FILL REQUIREMENT UNDER THE FOOTING. N 5" CONCRETE SLAB, USE F'C MIN = 2,500 PSI. CONCRETE SLAB TO BE UNDERLAIN BY MINIMUM 3 FEET OF ENGINEERED FILL OR DEPTH OF UNDOCUMENTED FILL WHICHEVER IS DEEPER March 25, 2025, TGR Geotechnical, Inc (TGR) TGR has reviewed these plans to confirm that the geotechnical parameters shown on the plans/calculations are in general accordance with our report. Our signature on these plans shall not be considered as acceptance or review of the structural design and calculations. 3 2039 N Victoria Drive #24/28/2025 ROOF FRAMING PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" S102 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 A B C 1 2 3 1 2 3 A B C ROOF 1. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSION SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLOCKING. USE 1/2" THICK STRUCTURAL SHEATHING FOR ROOF PANELS 2. NAILS ALONG INTERMEDIATE FRAMING MEMBERS AND BLOCKING FOR PANELS SHALL BE THE SAME SIZE AS INSTALLED AT THE PANEL EDGES. MAXIMUM NAIL SPACING SHALL BE 6" ON CENTER FOR MAIN FRAMING AND 12" ON CENTER FOR INTERMEDIATE FRAMING MEMBERS AND BLOCKING 3. ADD FULL-DEPTH BLOCKING BETWEEN RAFTERS AT TOP PLATE AND EVERY 4'. HOLES MAY BE DRILLED INTO CENTER OF BLOCKING TO ACHIEVE ATTIC VENTILATION REQUIREMENTS AS LONG AS AREA IS NOT REDUCED MORE THAN 30%. 4. ROOF TRUSSES TO BE DESIGNED AND FABRICATED BY MANUFACTURER / OTHER. ATTIC VENT CALCULATION : ATTIC VENTILATION NOTES: 20'-0"14'-0" 39 ' - 0 " 15 ' - 7 " 5:12 PROVIDE GAF TIMBERLINE CLASS A SHINGLE ROOF, FIRE RETARDANT CLASS A (ANSI/UL 790) WITH (2) #15 FELT UNDER LAYMENT (ESR-1475) 5:12 5:12 5: 1 2 5: 1 2 1'-6" 1' - 6 " 1'-6" 1' - 6 " 1'-6" 1' - 6 " 1'-6" 1' - 6 " 1'-6" 1' - 6 " ROOF FRAMING ROOF PLAN SKYLIGHT SKYLIGHT SKYLIGHT SKYLIGHTSKYLIGHT SKYLIGHT ATTIC GABLE VENT WITH 100 SQ.IN CLEAR VENT. (N) 6 ROOF EAVE VENTS WITH 13 NET SF VENTILATION AREA (3) 5-FT RIDGE VENT WITH 90 SQ.IN CLEAR VENT. USE GAF COBRA RIDGE VENT 3) (N) 11 ROOF EAVE VENTS WITH 13 NET SF VENTILATION AREA 33 ' - 3 " 2X 6 R R / C J @ 1 6 " O. C . U S E D F N O . 2 2X6 RR/CJ @ 16" O.C. USE DF NO.2 2X 6 R R / C J @ 1 6 " O. C . U S E D F N O . 2 2X10 RR @ 24" O.C. USE DF NO.2 2X10 RR @ 24" O.C. USE DF NO.2 2X10 RR @ 24" O.C. USE DF NO.2 2X10 RR @ 24" O.C. USE DF NO.2 2X6 RR/CJ @ 16" O.C. USE DF NO.2 5. 2 5 " X 1 8 " 2 . 2 E P S L R I D G E B E A M 2X8 DF NO.2 RIDGE BOARD 2X8 DF NO.2 RIDGE BOARD PER DETAIL 5/S104 SKYLIGHT SKYLIGHT SKYLIGHTSKYLIGHT SKYLIGHT SKYLIGHT 1 S104 1 S104 2 S104 2 S104 3 S104 3 S104 4 S104 5 S104 6 S104 OVERFRAMING PER DETAIL 7/S104 2X10 RR @ 24" O.C. USE DF NO.2 2X6 RR/CJ @ 16" O.C. USE DF NO.2 7 S10 4 17 S105 S105 N 1 S104 6-FT RIDGE VENT WITH 108 SQ.IN CLEAR VENT. USE GAF COBRA RIDGE VENT 3) 6-FT RIDGE VENT WITH 108 SQ.IN CLEAR VENT. USE GAF COBRA RIDGE VENT 3) (N) 6 ROOF EAVE VENTS WITH 13 NET SF VENTILATION AREA (2) DORMER VENT WITH 90 SQ.IN CLEAR VENT. ALL SKYLIGHTS TO BE MANUFACTURED BY VELUX IN ACCORDANCE WITH UES-ER REPORT #199 OR CONTRACTOR TO PROVIDE EQUIVALENT FOR SUBSTITUTION. SKYLIGHTS AND SLOPED GLAZING SHALL COMPLY WITH SECTION R308.6. 6X6 HDR 6X6 HDR 18 4X 6 H D R 6X 6 H D R 6X 6 H D R 6X 6 H D R 6X 6 H D R 6X 8 H D R 6X6 HDR 5-1/4x11-7/8 2.2E PSL HDR ATTACH BEAM TO 4X6 POST PER DETAIL 9/S104 ATTACH RIDGE BEAM POST TO DOOR HEADER PER DETAIL 8/S104 CS18 STRAP PER DETAIL 18/S105 2039 N Victoria Drive #24/28/2025 WALL FRAMING PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" S103 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 A B C 1 2 3 1 2 3 A B C 39 ' - 0 " SHEAR WALL SCHEDULE Panel Size Edge Nailing Field Nailing Edge Hold downsX TYP 16 WSP 7/16"6" - 8D 12" - 8D 1. Use 3"x3"x0.229" steel plate washers between anchor bolt and sill plate. Regardless of spacing, anchor bolts to occur within 2'-0" of shear wall end and min (2) anchor bolts per sill plate on ground floor. 2. Where required, drill into existing footing to grout anchor bolts using Simpson SET-3G High-Strength Epoxy Adhesive (ICC-ES ESR-4057). Achieve embedment depth of 8". 3. Attach HDU2 to new footings per DETAIL 16/S105. 4. Block all shear walls 5. WSP sheathing may be applied to interior or exterior face of walls where indicated 6. Restoring moment due to dead load is greater than overturning moment due to seismic load Sill Plate1,2LRFD Design Strength (plf) 380 HDU2 1/2" dia. anchor bolt every 4' o.c. TYP 2 WSP 7/16"6" - 8D 12" - 8D 380 N/A 1/2" dia. anchor bolt every 4' o.c. HEADER SCHEDULE A 4x6 Douglas Fir No.2 1 - 2x6 Header Size Jack Studs Trimmers 1 Material B 4x6 16x6Douglas Fir No.2 C 4x6 16x8Douglas Fir No.2 D 4x6 15.25x11.875 2.2E PSL 2'-8"2'-8"14'-8" 4'4'-5"4'-7" HDU5TYP 3 WSP 7/16"2" - 8D 6" - 8D 935 1/2" dia. anchor bolt every 4' o.c. 1 1 2 3 3 18'-10"13'-2" 2' - 8 " 2' - 8 " 10 ' - 3 " 9' - 1 " 3' - 3 " 1 2 2 2 2 HDU2 HDU2 HDU5 HDU2 HDU2 HDU5 12'-4" HDU2 HDU5 HDU5 HDU2 HDU2 HDU2 HDU2 CB46 D C B B B B B B B A A A A A 4X6 DF NO.2 CEILING BEAM TO SUPPORT SOFFIT WALL TO ROOF (NO ROOF LOAD ON CEILING BEAM) A CONTINUOUS HEADER ACROSS BOTH WINDOWS AND SHEATHING PER DETAIL 10/S105 (NOT INCLUDED IN SHEAR WALL CALCULATIONS) ATTACH BEAM TO 4X6 POST PER DETAIL 9/S104 ATTACH RIDGE BEAM POST TO DOOR HEADER PER DETAIL 8/S104 HDU2 HDU2 N STATEMENT OF SPECIAL INSPECTION THIS STATEMENT OF SPECIAL INSPECTIONS IS SUBMITTED IN FULFILLMENT OF THE REQUIREMENTS OF CBC SECTIONS 1704 AND 1705. SPECIAL INSPECTIONS AND TESTING WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS, THIS STATEMENT AND CBC SECTIONS 1704, 1705, 1707, AND 1708. THE BELOW SCHEDULE OF SPECIAL INSPECTIONS SUMMARIZES THE SPECIAL INSPECTIONS AND TESTS REQUIRED. SPECIAL INSPECTORS WILL REFER TO THE APPROVED PLANS AND SPECIFICATIONS FOR DETAILED SPECIAL INSPECTION REQUIREMENTS. ANY ADDITIONAL TESTS AND INSPECTIONS REQUIRED BY THE APPROVED PLANS AND SPECIFICATIONS WILL ALSO BE PERFORMED. SPECIAL INSPECTION FREQUENCY CONTACT BOLTS POST-INSTALLED IN CONCRETE USING EPOXY-BASED ADHESIVE FIRM NAME PERIODIC TBD, REGISTERED DEPUTY INSPECTOR TBD, REGISTERED DEPUTY INSPECTOR SHEAR WALL WITH NAIL SPACING <4" O.C. (TYP 3)CONTINUOUS TBD, REGISTERED DEPUTY INSPECTOR TBD, REGISTERED DEPUTY INSPECTOR 2039 N Victoria Drive #24/28/2025 1 2 4 5 6 3 7 8 9 STRUCTURAL DETAILS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS S104 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 ROOF SHEAR TRANSFER 2x Fascia (fire treated where 1-hr rated) Edge Nailing (E.N.) per plan 2x Blocking Attach 2x roof blocking to top plate using Simpson A35 shear clips installed at 30" o.c. with 3"-6" nails Attach rafter to wall top plate using Simpson H2.5A Tie (7) 16d nails 2X6 #2 CJ @ 16" O.C. 8D Edge Nailing @ 6" O.C. 7/16" WSP Shear Wall where applicable 2X6 #2 RR @ 16" O.C. Metal drip edge Mineral fiber insulation R-30 1 2" Drywall #2 2x6 Double Top Plate #2 2x6 Studs @ 16" O.C. with Mineral Fiber insulation R-21 in cavity with R-5 rigid insulation at exterior face 1 2" Drywall #2 Layer type "D" paper & stucco wire 7 8" Stucco 18" 7/16" Plywood CDX w/ 8D @ 6,6,12" O.C. #15 or 30 Felt Asphalt Shingles Class "A" ROOF SHEAR TRANSFER 2x Fascia (fire treated where 1-hr rated) Edge Nailing (E.N.) per plan 2x Blocking Attach rafter to wall top plate using Simpson H2.5A Tie 7/16" WSP Shear Wall where applicable 2X10 #2 RR @ 24" O.C. Metal drip edge Mineral fiber insulation R-30 (Min 1" air gap between sheathing and insulation) 1x6 T&G Pine ceiling planks 1 2" Drywall 18" #15 or 30 Felt Asphalt Shingles Class "A" Rafter tail trimmed to resemble 2x6 #2 2x6 Double Top Plate #2 2x6 Studs @ 16" O.C. with Mineral Fiber insulation R-21 in cavity with R-5 rigid insulation at exterior face ROOF GABLE SHEAR TRANSFER 2X10 #2 RR @ 16" O.C. 2x Blocking E.N. 2x6 Continuous outrigger every 24" 7/16" Plywood CDX w/ 8D @ 6,6,12" O.C. E.N. 2x Fascia (fire treated where 1-hr rated) Cripple Studs to match wall below 7/16" WSP Shear Wall where applicable #2 2x6 Double Top Plate Attach 2x roof blocking to top plate using Simpson A35 shear clips installed at 32" o.c. (2) 2x6 blocking between outriggers over top plate 2x4 lateral bracing @ 24" o.c. 1 2" Drywall (5) 16d nails (5) 16d nails 1 2" Drywall Mineral fiber insulation R-30 18" #2 Layer type "D" paper & stucco wire 7 8" Stucco 2X6 #2 CJ @ 16" O.C. #2 2x6 Studs @ 16" O.C. with Mineral Fiber insulation R-21 in cavity with R-5 rigid insulation at exterior face ROOF GABLE SHEAR TRANSFER 2X10 #2 RR @ 24" O.C. 2x8 Blocking @ 24" o.c where decorative beam occurs E.N. 2x6 Continuous outrigger every 24" 7/16" Plywood CDX w/ 8D @ 6,6,12" O.C. E.N. 2x Fascia 7/16" WSP Shear Wall where applicable #2 2x6 Double Top Plate Attach 2x roof blocking to top plate using Simpson A35 shear clips installed at 32" o.c. (2) 2x6 blocking between outriggers over top plate 1 2" Drywall Mineral fiber insulation R-30 (Min 1" air gap between sheathing and insulation) 12" #2 Layer type "D" paper & stucco wire 7 8" Stucco 4x6 Decorative roof beam exposed. Attach beam to blocking using Simpson A34 clips #2 2x6 Studs @ 16" O.C. with Mineral Fiber insulation R-21 in cavity with R-5 rigid insulation at exterior face ROOF RIDGE TO RAFTER CONNECTION 2x8 ridge board to serve as a nailing plate for rafters and provide uniform bearing of rafters 2X6 #2 RR @ 16" O.C. Attach rafters to ridge board using Simpson Strong Tie angled rafter hangers Tie rafters using Simpson Strong Tie ST 2115 strap w/10-16d @ 48" O.C. 5 12 Asphalt Shingles Class "A" #15 or 30 felt 7/16" Plywood CDX w/ 8D @ 6,6,12" O.C ROOF RIDGE BEAM (N) 2x10 Roof rafter @ 24" o.c. Attach blocking to ridge beam using Simpson A35 clip every 30" o.c. 5.25"x18" 2.2E PSL Ridge beam Attach roof rafters to ridge beam using angled Simpson joist hangers 7/16" Roof sheathing with w/ 8D nailing @ 6,6,12" O.C. (N) 2x4 Blocking between roof rafters, leave 1" for ventilation air gap Roof ridge vent where occurs. Simpson concealed joist tie (CJT3Z) Mineral fiber insulation R-30 (Min 1" air gap between sheathing and insulation) 4x6 Decorative roof beam exposed 7/16" Roof Sheathing B.N. Typ 2x Flat continuous with 16d @ 6" o.c. 7/16" Roof Sheathing 2x6/2x10 Roof Rafter 2x Solid Blocking 2x6 Roof Rafters w/ Simpson A35 ea. side connecting to 2x flat board ROOF OVERLAY FRAMING 6x6 column post 2x6 post nailed to 4x6 column post using 6d nails every 6" o.c. 5-1/4"x18" 2.2E PSL Ridge Beam Simpson Strong Tie column cap (ECCU64) Simpson strong tie column caps (ECCU66) 5-1/4x11-7/8 2.2E PSL door/window Header Simpson A35 clip on each side of 6x6 post RIDGE BEAM OVER WINDOW HEADER Simpson HTP37Z tie on each side of 6x6 post 4x6 header post BEAM TO POST CONNECTION (TYP END) 4X6 Stud column (match beam width) for beam to bear directly atop. Attach beams and column using Simpson column cap (ECCU64 to match beam width). 5-1/4"x18" 2.2E PSL Ridge Beam Eaves and soffits shall be non-combustible, ignition-resistant or have a layer of 5/8” Type X fiber cement board sheathing on south and east side (<5-ft PL) Eaves and soffits shall be non-combustible, ignition-resistant or have a layer of 5/8” Type X fiber cement board sheathing on south side (<5-ft PL) Attach 2x roof blocking to top plate using Simpson A35 shear clips installed at 30" o.c. with 3"-6" nails 8D Edge Nailing @ 6" O.C. 7/16" Plywood CDX w/ 8D @ 6,6,12" O.C. Eaves and soffits shall be non-combustible, ignition-resistant or have a layer of 5/8” Type X fiber cement board sheathing on east side (<5-ft PL) 2039 N Victoria Drive #24/28/2025 11 13 14 15 12 16 STRUCTURAL DETAILS NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS S105 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 10 SPECIAL WALL NAILING AROUND WINDOW OPENING Simpson Strong Tie CS18 strap across top and bot of window. Continue min 16" onto studs 6x6 DF No.2 window header to remain continuous across both new windows New Window Opening 3x flat blocking at sill height 2x6 king stud 4x6 post at wall edge Continuous WSP 7/16" sheathing with 8d common nails at 3" o.c. in all framing (studs, blocking and sills) around window openings 3x flat blocking at top of window 32"17" Simpson Strong Tie CS18 strap across bot of window in center (between new windows). Continue min 16" onto studs New Window Opening 17"32"17" 7 8" Stucco #2 2x6 Studs @ 16" O.C. with Mineral Fiber insulation R-21 in cavity with R-5 rigid insulation at exterior face 1/2" dia. anchor bolt every 4' o.c. Embed min 7". Bolt holes shall be max 1 16" oversized. Inspector to verifyMetal weep screed (min 26 ga. corrosion-resistant) w/ brush coat stucco finish below. height above paved surfaces may be min 2". vertical attachment flange min 3-1/2" length Use 3"x3"x0.229" steel plate washers between bolt and sill plate 5" concrete slab using min 2,500 psi concrete #4 rebar @ 16" o.c. each way throughout slab 15-mil vapor barrier beneath slab Capillary break consisting of 4-inch-thick gravel base of 1/2 inch or larger clean aggregate #4 vertical reinforcement every 16" o.c. Bend reinforcing and extend into slab min 24" (2) #4 rebar at bot and top of thickened edge with 3" clear cover 18" 24 " mi n 8 " E.N. Thicken perimeter edge to depth of 24" for 18" width 7/16" WSP Shear Wall where applicable All continuous footings overtop demolished pool to be placed over a minimum of three feet of engineered fill. Deeper engineered fill may be required due to presence of undocumented fill (see soils report) WALL FOOTING DETAIL 7 8" Stucco #2 2x6 Studs @ 16" O.C. with Mineral Fiber insulation R-21 in cavity with R-5 rigid insulation at exterior face 1/2" dia. anchor bolt every 4' o.c. Embed min 7". Bolt holes shall be max 1 16" oversized. Inspector to verifyMetal weep screed (min 26 ga. corrosion-resistant) w/ brush coat stucco finish below. height above paved surfaces may be min 2". vertical attachment flange min 3-1/2" length Use 3"x3"x0.229" steel plate washers between bolt and sill plate 5" concrete slab using min 2,500 psi concrete #4 rebar @ 16" o.c. each way throughout slab 15-mil vapor barrier beneath slab Capillary break consisting of 4-inch-thick gravel base of 1/2 inch or larger clean aggregate #4 vertical reinforcement every 16" o.c. Bend reinforcing and extend into slab min 24" (2) #4 rebar at bot and top of thickened edge with 3" clear cover 18" 24 " E.N. Thicken perimeter edge to depth of 24" for 18" width 7/16" WSP Shear Wall where applicable All continuous footings overtop or near demolished pool to be placed over a minimum of three feet of engineered fill. Deeper engineered fill may be required due to presence of undocumented fill (see soils report) WALL FOOTING DETAIL mi n 2 " 5" concrete patio slab using min 2,500 psi concrete 24 " 5" Thickened slab, use F'c min = 2,500 psi 1/2" dia. anchor bolt every 4' o.c. Embed min 7". Use 3"x3"x0.229" steel plate washers between bolt and sill plate #4 steel longitudinal reinforcement, 3" cover at top / bottom 18" 2 1 #4 rebar spaced at 16" o.c. both directions and placed at center thickness 2x4 stud wall (load bearing) 15-mil vapor barrier beneath new slab THICKENED SLAB DETAIL BENEATH INTERIOR LOAD-BEARING WALL Capillary break consisting of 4-inch-thick gravel base of 1/2 inch or larger clean aggregate New 4x6 post using DF No.2Bottom of post anchored to footing using Simpson Strong Tie post base (CB46) 24 " 30" (5) #4 rebar each way with 3" cover from bot 30x30x24 concrete pier. f'c min = 2,500 psi Interior 2x4 wall POST TO FOOTING CONNECTION #4 rebar spaced at 16" o.c. both directions and placed at center thickness 5" Thickened slab, use F'c min = 2,500 psi WOOD POST TO CONCRETE FOOTING 4x6 post using DF No.2Simpson HDU5 24"x24" Reinforced concrete square footing under post #4 Rebar @ 8" o.c. horizontal reinforcement each way Grade 12" 12" (2) #4 rebar tie continuous footing to spread footing (2) #4 steel longitudinal reinforcement, 2" cover at top and 2" cover at sides 2x6 Wall sill plate (anchor bolts into stem wall not shown) 24" New thickened perimeter edge SHEAR WALL HOLD DOWN DF No.2 4x6 end post Wall sill plate (anchor bolts not shown) 5 8" Dia. anchor bolt embedded MIN 8" into perimeter footing. Place bolt before casting fresh concrete or epoxy anchor after curing using Simpson Set-3G High-strength epoxy adhesive (ICC-ES ESR-4057). Structural deputy inspection is required for all hold-down epoxy anchors HDU Simpson hold down per plan MI N 8 " New concrete perimeter footing Concrete floor slab Min edge distance of 1-3/4" from footing edge 17 (N) 2X6 Rafters / over-framing with 5:12 slope using DF No.2 @ 16" o.c. LIVINGLIVING (N) 2X6 Ceiling joist @ 16" o.c. (N) 2X6 Ceiling joist @ 16" o.c. 2x Blocking 8D Edge Nailing @ 6" O.C. 7/16" WSP Shear Wall (continues in attic) Mineral fiber insulation R-30 1 2" Drywall #2 2x4 Double Top Plate 1 2" Drywall 7/16" Plywood CDX w/ 8D @ 6,6,12" O.C. ROOF INTERSECTION 18 REENTRANT CORNER STRAP 2x4 stud wall (coming out of page) 2x4 stud wall Flat blocking at strap location Install Simpson CS18 drag strap across perpendicular top plates at reentrant corner. Strap to extend min 10" onto both top plates 2X6 #2 RR @ 16" O.C.2X6 #2 RR @ 16" O.C. (N) 2X6 Ceiling joist @ 16" o.c. 2x Blocking between ceiling joists/rafters Install Simpson CS18 drag strap across perpendicular rafters. Strap to extend min 16" onto both roof sections. 2X10 #2 RR @ 24" O.C. All continuous footings overtop demolished pool to be placed over a minimum of three feet of engineered fill. Deeper engineered fill may be required due to presence of undocumented fill (see soils report) March 25, 2025, TGR Geotechnical, Inc (TGR) TGR has reviewed these plans to confirm that the geotechnical parameters shown on the plans/calculations are in general accordance with our report. Our signature on these plans shall not be considered as acceptance or review of the structural design and calculations. 2039 N Victoria Drive #24/28/2025 TITLE 24 ENERGY COMPLIANCE NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS T101 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page1of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 GENERAL INFORMATION 01 Project Name New Unit Construction 02 Run Title New Construction 03 Project Location 2039 N Victoria Dr 04 City Santa Ana, CA 05 Standards Version 2022 06 Zip code 92706 07 Software Version CBECC-Res2022.3.1 08 Climate Zone 8 09 Front Orientation (deg/Cardinal) 270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 1 14 Addition Cond. Floor Area (ft2) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2) n/a 17 Fenestration Average U-factor 0.31 18 Total Cond. Floor Area (ft2) 998 19 Glazing Percentage (%) 25.15% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type All electric 23 No Dwelling Unit: No 01 02 03 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. COMPLIANCE RESULTS Building Complies with Computer Performance This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. This building incorporates one or more Special Features shown below CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page2of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 ENERGY DESIGN RATINGS EnergyDesignRatings ComplianceMargins SourceEnergy (EDR1) Efficiency1EDR (EDR2efficiency) Total2EDR (EDR2total) SourceEnergy (EDR1) Efficiency1EDR (EDR2efficiency) Total2EDR (EDR2total) StandardDesign 36.3 36.7 53.7 ProposedDesign 34.4 36.6 53.7 1.9 0.1 0 RESULT3:PASS 1Efficiency EDRincludesimprovementslikeabetterbuildingenvelopeandmoreefficientequipment 2Total EDRincludesefficiencyanddemandresponsemeasuressuchasphotovoltaic(PV)systemandbatteries 3Building complieswhensourceenergy,efficiencyandtotalcompliancemarginsaregreaterthanorequaltozeroandunmetloadhourlimitsarenotexceeded •Standard Design PV Capacity: 0.00 kW dc •PV System(s) removed due to Reduced PV Requirement of 0kW dc 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page3of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 ENERGY USE SUMMARY EnergyUse StandardDesignSource Energy(EDR1)(kBtu/ft2-yr) StandardDesignTDVEnergy (EDR2)(kTDV/ft2-yr) ProposedDesignSource Energy(EDR1)(kBtu/ft2-yr) ProposedDesignTDVEnergy (EDR2)(kTDV/ft2-yr)Margin(EDR1) Margin(EDR2) SpaceHeating 0.6 2.74 0.82 5.82 -0.22 -3.08 SpaceCooling 0.84 23.14 0.73 26.48 0.11 -3.34 IAQVentilation 0.34 3.6 0.34 3.6 0 0 WaterHeating 1.67 17.68 0.95 11.13 0.72 6.55 Self Utilization/Flexibility Credit 0 0 0 0 EfficiencyCompliance Total 3.45 47.16 2.84 47.03 0.61 0.13 Photovoltaics 0 0 0 0 Battery 0 0 Flexibility 0 IndoorLighting 0.86 8.06 0.86 8.06 Appl.&Cooking 3.46 41.62 3.46 41.59 PlugLoads 3.62 36.84 3.62 36.84 OutdoorLighting 0.2 1.75 0.2 1.75 TOTALCOMPLIANCE 11.59 135.43 10.98 135.27 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page4of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 ENERGY USE INTENSITY StandardDesign(kBtu/ft2-yr) ProposedDesign(kBtu/ft2-yr)Margin(kBtu/ft2-yr)MarginPercentage GrossEUI1 16.01 15.35 0.66 4.12 NetEUI2 16.01 15.35 0.66 4.12 Notes 1.GrossEUIisEnergyUseTotal(notincludingPV)/TotalBuildingArea. 2.NetEUIisEnergyUseTotal(includingPV)/TotalBuildingArea. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DCSystemSize (kWdc)Exception ModuleType ArrayType PowerElectronics CFI Azimuth (deg) Tilt Input ArrayAngle (deg) Tilt:(xin 12) InverterEff. (%) Annual SolarAccess (%) 0 NoPV-requiredPV lessthan1.8kWdc Standard(14-17%)Fixed none true n/a n/a n/a n/a n/a REQUIRED SPECIAL FEATURES •PV exception 2: No PV required when minimum PV size (Section150.1(c)14)<1.8kWdc(0kW) •Cool roof •Insulation below roof deck •Compact distribution system basic credit •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page5of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 HERS FEATURE SUMMARY •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Verified heat pump rated heating capacity BUILDING-FEATURESINFORMATION 01 02 03 04 05 06 07 ProjectName ConditionedFloorArea(ft2)NumberofDwelling Units NumberofBedrooms NumberofZones NumberofVentilation CoolingSystems NumberofWater HeatingSystems NewUnitConstruction 998 1 1 1 0 1 ZONEINFORMATION 01 02 03 04 05 06 07 ZoneName ZoneType HVACSystemName ZoneFloorArea(ft2)Avg.CeilingHeight WaterHeatingSystem1 Status ADU Conditioned NewADUHVAC 998 9 HeatPumpWH New OPAQUESURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation GrossArea(ft2)WindowandDoor Area(ft2)Tilt(deg) WallFront ADU R-21WallStucco 270 Front 351 89.02 90 WallLeft ADU R-21WallStucco 0 Left 348 116.02 90 WallBack ADU R-21WallStucco 90 Back 351 0 90 WallRight ADU R-21WallStucco 180 Right 348 4 90 Ceiling(belowattic)ADU R-30Ceiling n/a n/a 378 n/a n/a 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page6of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 OPAQUE SURFACES-CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Area(ft2) SkylightArea (ft2) RoofRise(xin 12) Roof Reflectance RoofEmittance CoolRoof Cathedral CeilingFront ADU RoofCeiling 270 Front 310 21 5 0.2 0.85 Yes Cathedral CeilingBack ADU RoofCeiling 90 Back 310 21 5 0.2 0.85 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type RoofRise(xin12)RoofReflectance RoofEmittance RadiantBarrier CoolRoof Attic AsphaltShingleRoof Ventilated 5 0.2 0.85 No Yes FENESTRATION/GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGCSource ExteriorShading F1 Window WallFront Front 270 6 6.67 1 40.02 0.3 NFRC 0.23 NFRC BugScreen F2 Window WallFront Front 270 2 6 2 24 0.3 NFRC 0.23 NFRC BugScreen F3 Window WallFront Front 270 2.5 2 5 25 0.3 NFRC 0.23 NFRC BugScreen L1 Window WallLeft Left 0 6 6.67 1 40.02 0.3 NFRC 0.23 NFRC BugScreen L2 Window WallLeft Left 0 2 6 4 48 0.3 NFRC 0.23 NFRC BugScreen L3 Window WallLeft Left 0 2 3.5 4 28 0.3 NFRC 0.23 NFRC BugScreen R1 Window WallRight Right 180 2 2 1 4 0.3 NFRC 0.23 NFRC BugScreen Skylight1 Skylight Cathedral CeilingFront Front 270 3 21 0.38 NFRC 0.25 NFRC 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page7of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 FENESTRATION/GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGCSource ExteriorShading Skylight2 Skylight Cathedral CeilingBack Back 90 3 21 0.38 NFRC 0.25 NFRC SLABFLOORS 01 02 03 04 05 06 07 08 Name Zone Area(ft2)Perimeter(ft)EdgeInsul.R-value andDepth EdgeInsul.R-value andDepth CarpetedFraction Heated SlabOnGrade ADU 998 146 none 0 80%No OPAQUESURFACECONSTRUCTIONS 01 02 03 04 05 06 07 08 ConstructionName SurfaceType ConstructionType Framing TotalCavity R-value Interior/Exterior Continuous R-value U-factor AssemblyLayers R-21WallStucco ExteriorWalls WoodFramedWall 2x6@16in.O.C.R-21 None/5 0.048 InsideFinish:GypsumBoard Cavity/Frame:R-21/2x6 Sheathing/Insulation:R-5Sheathing ExteriorFinish:3CoatStucco RoofCeiling CathedralCeilings WoodFramed Ceiling 2x10@24in.O.C.R-30 None/None 0.035 Roofing:LightRoof(AsphaltShingle) RoofDeck:Wood Siding/sheathing/decking Cavity/Frame:R-30/2x10 InsideFinish:GypsumBoard AsphaltShingleRoof AtticRoofs WoodFramed Ceiling 2x6@16in.O.C.R-19 None/None 0.058 Roofing:LightRoof(AsphaltShingle) RoofDeck:Wood Siding/sheathing/decking Cavity/Frame:R-19/2x6 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page8of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 OPAQUESURFACECONSTRUCTIONS 01 02 03 04 05 06 07 08 ConstructionName SurfaceType ConstructionType Framing TotalCavity R-value Interior/Exterior Continuous R-value U-factor AssemblyLayers R-30Ceiling Ceilings(below attic) WoodFramed Ceiling 2x6@16in.O.C.R-30 None/None 0.032 OverCeilingJoists:R-15.7insul. Cavity/Frame:R-14.3/2x6 InsideFinish:GypsumBoard BUILDINGENVELOPE-HERSVERIFICATION 01 02 03 04 05 QualityInsulationInstallation(QII)HighR-valueSprayFoamInsulation BuildingEnvelopeAirLeakage CFM50 CFM50 Required NotRequired N/A n/a n/a WATERHEATINGSYSTEMS 01 02 03 04 05 06 07 08 09 Name SystemType DistributionType WaterHeaterName NumberofUnits SolarHeating System Compact Distribution HERSVerification WaterHeater Name(#) HeatPumpWH DomesticHot Water(DHW)Standard HeatPumpWater Heater 1 n/a Basic n/a HeatPumpWater Heater(1) WATERHEATERS-NEEAHEATPUMP 01 02 03 04 05 06 07 08 Name #ofUnits TankVol.(gal)NEEAHeatPump Brand NEEAHeatPump Model TankLocation DuctInletAirSource DuctOutletAirSource HeatPumpWater Heater 1 50 A.O.Smith HPTS-502**(50gal, JA13)Outside Outside Outside 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page9of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 WATERHEATING-COMPACTDISTRIBUTION 01 02 03 04 05 06 07 DwellingUnittype WaterHeatingSystem Name MasterBathdistanceof furthestfixturetoWater Heater(ft) Kitchendistanceof furthestfixturetoWater Heater(ft) FurthestThirdfurthest fixturetoWaterHeater (ft) CompactnessFactor HERSVerification Dwelling HeatPumpWH n/a n/a n/a 0.7 n/a WATERHEATING-HERSVERIFICATION 01 02 03 04 05 06 07 Name PipeInsulation ParallelPiping CompactDistribution CompactDistribution Type RecirculationControl ShowerDrainWaterHeat Recovery HeatPumpWH-1/1 NotRequired NotRequired NotRequired Basic NotRequired NotRequired SPACECONDITIONINGSYSTEMS 01 02 03 04 05 06 07 08 09 Name SystemType HeatingUnitName HeatingEquipment Count CoolingUnitName CoolingEquipment Count FanName DistributionName Required ThermostatType NewADUHVAC Heatpump heatingcooling HVACHeatPump 1 HVACHeatPump 1 HVACFan Ducts Setback HVAC-HEATPUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name SystemType Numberof Units Heating Cooling Zonally Controlled Compressor Type Heating HERSVerificationEfficiency Type HSPF/HS PF2/COP Cap47 Cap17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER HVACHeatPump CentralsplitHP 1 HSPF2 7.5 30000 30000 EER2SEER2 18 12.48 NotZonal Single Speed HVACHeat Pump-hers-htpump 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page10of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 HVACHEATPUMPS-HERSVERIFICATION 01 02 03 04 05 06 07 08 09 Name VerifiedAirflow AirflowTarget VerifiedEER/EER2 Verified SEER/SEER2 VerifiedRefrigerant Charge Verified HSPF/HSPF2 VerifiedHeating Cap47 VerifiedHeating Cap17 HVACHeat Pump-hers-htpump Required 350 NotRequired Required Yes No Yes Yes HVAC-DISTRIBUTIONSYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type DesignType DuctIns.R-value DuctLocation SurfaceArea BypassDuct DuctLeakage HERSVerificationSupplyReturnSupplyReturnSupplyReturn Ducts Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a NoBypassDuct Existing(not specified)Ducts-hers-dist HVAC-FANSYSTEMS 01 02 03 04 Name Type FanPower(Watts/CFM)Name HVACFan HVACFan 0.45 HVACFan-hers-fan HVACFANSYSTEMS-HERSVERIFICATION 01 02 03 Name VerifiedFanWattDraw RequiredFanEfficacy(Watts/CFM) HVACFan-hers-fan Required 0.45 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page11of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 DwellingUnit Airflow(CFM)FanEfficacy (W/CFM)IAQFanType Includes Heat/Energy Recovery? IAQRecovery Effectiveness- SRE/ASRE IncludesFault IndicatorDisplay?HERSVerification Status SFamIAQVentRpt 44 0.35 Exhaust No n/a/n/a No Yes 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page12of12) CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22 RegistrationNumber:RegistrationDate/Time:  HERSProvider: CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000 SchemaVersion:rev20220901 ReportGenerated:2025-03-07   13:54:06 DocumentationAuthorName:DocumentationAuthorSignature: Company:SignatureDate: Address:CEA/HERSCertificationIdentification(Ifapplicable): City/State/Zip:Phone: 1. 2. 3. ResponsibleDesignerName:ResponsibleDesignerSignature: Company:DateSigned: Address:License: City/State/Zip:Phone: Jeffrey Schaefer JRS Engineering & Design 03/07/2025 3325 E 4th Long Beach, CA 80914 5628501223 Jeffrey Schaefer JRS Engineering & Design 03/07/2025 3325 E 4th C91734 Long Beach, CA 80914 5628501223 425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title24, Part1 and Part 6 of the California Code of Regulations. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 2039 N Victoria Drive #24/28/2025 CALIFORNIA GREEN MANDATORY MEASURES NEW DETACHED ADU 2039 N VICTORIA DR SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS T102 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2.Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2.Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2.Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2.Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7.Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2.Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2.Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Sections 4.106.4.1 or 4.106.4.2 to facilitate future installation and use of EV chargers. Electric vehicle supply equipment (EVSE) shall be installed in accordance with the California Electrical Code, Article 625. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE.Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Sections 4.106.4.2.1 and 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1Multifamily development projects with less than 20 dwelling units; and hotels and motels with less than 20 sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exceptions: 1.When EV chargers (Level 2 EVSE) are installed in a number equal to or greater than the required number of EV capable spaces. 2.When EV chargers (Level 2 EVSE) are installed in a number less than the required number of EV capable spaces, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed. Notes: a.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 4.106.4.2.2 Multifamily development projects with 20 or more dwelling units, hotels and motels with 20 or more sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exception: When EV chargers (Level 2 EVSE) are installed in a number greater than five (5) percent of parking spaces required by Section 4.106.4.2.2, Item 3, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed over the five (5) percent required. Notes: a.Construction documents shall show locations of future EV spaces. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 3.EV Chargers. Five (5) percent of the total number of parking spaces shall be equipped with Level 2 EVSE. Where common use parking is provided, at least one EV charger shall be located in the common use parking area and shall be available for use by all residents or guests. When low power Level 2 EV charging receptacles or Level 2 EVSE are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EVSE shall have a capacity of not less than 30 amperes. ALMS shall not be used to reduce the minimum required electrical capacity to the required EV capable spaces. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 3, shall comply with Section 4.106.4.2.2.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Location. EVCS shall comply with at least one of the following options: 1.The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. 2.The charging space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1 and Section 4.106.4.2.2.1.2, Item 3. 4.106.4.2.2.1.2 Electric vehicle charging stations (EVCS) dimensions. The charging spaces shall be designed to comply with the following: 1.The minimum length of each EV space shall be 18 feet (5486 mm). 2.The minimum width of each EV space shall be 9 feet (2743 mm). 3.One in every 25 charging spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm). a.Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. 4.106.4.2.2.1.3 Accessible EV spaces. In addition to the requirements in Sections 4.106.4.2.2.1.1 and 4.106.4.2.2.1.2, all EVSE, when installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 EV space requirements. 1.Single EV space required. Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the location or the proposed location of the EV space. Construction documents shall identify the raceway termination point, receptacle or charger location, as applicable. The service panel and/ or subpanel shall have a 40-ampere minimum dedicated branch circuit, including branch circuit overcurrent protective device installed, or space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space, at the time of original construction in accordance with the California Electrical Code. 2.Multiple EV spaces required. Construction documents shall indicate the raceway termination point and the location of installed or future EV spaces, receptacles or EV chargers. Construction documents shall also provide information on amperage of installed or future receptacles or EVSE, raceway method(s), wiring schematics and electrical load calculations. Plan design shall be based upon a 40-ampere minimum branch circuit. Required raceways and related components that are planned to be installed underground, enclosed, inaccessible or in concealed areas and spaces shall be installed at the time of original construction. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. Y N/A RESPON. PARTY PARTY PARTY PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (January 2023)Y = YES N/A = NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (I.E CONTRACTOR-CTR, INSPECTOR - INSP, ARCHITECT - ARCH) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space at the time of original construction in accordance with the California Electrical Code. 4.106.4.2.4 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. 4.106.4.2.5 Electric Vehicle Ready Space Signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multifamily buildings. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. X N/A X N/A X N/A X CTR X N/A X N/A X N/A X N/A X N/A X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR Y N/A RESPON.Y N/A RESPON.Y N/A RESPON. 2039 N Victoria Drive #24/28/2025 CALIFORNIA GREEN MANDATORY MEASURES NEW DETACHED ADU 2039 N VICTORIA DR SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS T103 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING.HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1.State certified apprenticeship programs. 2. Public utility training programs. 3.Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD].When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3.Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1.Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION.Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3.A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a.Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2.Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3.Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3.Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. PARTY PARTY PARTY PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (January 2023) Y =YES N/A = NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (I.E CONTRACTOR-CTR, INSPECTOR - INSP, ARCHITECT - ARCH) X N/A X N/A X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X CTR X ARCH X ARCH Y N/A RESPON.Y N/A RESPON.Y N/A RESPON.Y N/A RESPON. 2039 N Victoria Drive #24/28/2025 NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 NTS T104 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 TITLE 24 SFR MANDATORY MEASURES 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * § 110.6(a)5:Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. § 110.8(a):Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). § 110.8(g):Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. § 110.8(j):Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. § 150.0(a): Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * § 150.0(b):Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. § 150.0(c): Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * § 150.0(d):Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1: Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). § 150.0(g)2: Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. § 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: § 110.5(e)Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)1:Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * § 150.0(e)3:Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. * Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3: Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * § 110.2(a):HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. * § 110.2(b): Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * § 110.2(c): Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * § 110.3(c)3: Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. § 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters. * § 150.0(h)1: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. § 150.0(h)3A:Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. § 150.0(h)3B: Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. § 150.0(j)1: Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * § 150.0(j)2: Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. § 150.0(n)1: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater § 150.0(n)3: Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts and Fans: § 110.8(d)3: Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. § 150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in these spaces must not be compressed. * § 150.0(m)2: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7:Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. § 150.0(m)9: Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. § 150.0(m)10:Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. § 150.0(m)11: Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. § 150.0(m)12: Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: § 150.0(o)1:Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * § 150.0(o)1B:Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. § 150.0(o)1C: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. § 150.0(o)1G:Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * § 150.0(o)1H&I:Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. § 150.0(o)2: Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: § 110.4(a): Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. * § 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2:Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5:Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9. * § 150.0(k)1A:Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacy of at least 45 lumens per watt. § 150.0(k)1B:Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1C:Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. § 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1E:Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. § 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k). * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(k)1G:Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1I: Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A:Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B:Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems. * § 150.0(k)2A: Accessible Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off. * § 150.0(k)2B: Multiple Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comply with § 150.0(k). § 150.0(k)2C:Mandatory Requirements. Lighting controls must comply with the applicable requirements of § 110.9. § 150.0(k)2D: Energy Management Control Systems. An energy management control system (EMCS) may be used to comply with dimming, occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in § 150.0(k)2A. § 150.0(k)2E: Automatic Shutoff Controls. In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with opaque fronts or doors must have controls that turn the light off when the drawer or door is closed. § 150.0(k)2F: Dimmers. Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall- mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light sources in these spaces must comply with NEMA SSL 7A. § 150.0(k)2K:Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, lighting in display cabinets, and switched outlets must be controlled separately from ceiling-installed lighting. § 150.0(k)3A: Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must either comply with § 140.8 or consume no more than 5 watts of power. § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Solar Readiness: § 110.10(a)1: Single-family Residences. Single-family residences located in subdivisions with 10 or more single-family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b)-(e). §110.10(b)1A: Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. * § 110.10(b)2:Azimuth. All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. * § 110.10(b)3B: Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the horizontal distance of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.* § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. § 110.10(c): Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residences and central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b)-(c) must be provided to the occupant. § 110.10(e)1:Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. § 110.10(e)2:Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric.” Electric and Energy Storage Ready: 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(s)Energy Storage System (ESS) Ready. All single-family residences must meet all of the following: Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, or a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3’ of the main panelboard, with raceways installed between the panelboard and the switch location to allow the connection of backup power source. § 150.0(t)Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(u)Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(v)Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” *Exceptions may apply. 2039 N Victoria Drive #24/28/2025 PLUMBING 1. WATER CLOSET SHALL HAVE 15" TO ANY WALL OR OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24" CLEAR SPACE IN FRONT 2. PROVIDE ULTRA-FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. NEW PLUMBING FIXTURES MUST MEET THE FOLLOWING ENERGY EFFICIENCY FLOW RATES: 2.1. WATER CLOSETS - 1.28 GPF 2.2. SINGLE SHOWERHEADS - 1.8 GPF AT 80 PSI 2.3. MULTIPLE SHOWERHEADS - 1.8 GPF AT 80 PSI FOR ALL COMBINATIONS 2.4. LAVATORY FAUCETS - 1.2 GPM AT 60 PSI 2.5. LAVATORY FAUCETS IN PUBLIC USE AREAS - 0.5 GPM AT 60 PSI 2.6. KITCHEN FAUCETS - 1.8 GPM AT 60 PSI 3. SHOWERS AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING TYPE. HANDLE POSITION STOPS SHALL BE PROVIDED ON SUCH VALVES AND SHALL BE ADJUSTED PER MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUM MIXED WATER SETTING OF 120F. THE WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A SUITABLE CONTROL FOR MEETING THIS PROVISION 4. AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW SHUT OFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN-STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170,158 AND 180,670) SEPARATE PLUMBING PERMIT IS REQUIRED. 5. ABS PIPING SHALL NOT BE EXPOSED TO DIRECT SUNLIGHT UNLESS PROTECTED BY WATER-BASED SYNTHETIC LATEX PAINTS. (CPC 312.13) 6. UNDERGROUND WATER SUPPLY LINES SHALL HAVE A 14 AWG BLUE TRACER WIRE (METALLIC PIPE EXEMPT). (CPC 604.10.1) 7. PROVIDE ANTI-SIPHON VALVES ON ALL HOSE BIBS. (CPC 603.5.7) MECHANICAL 1. BATHROOM WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SF, ONE-HALF OF WHICH MUST BE ABLE TO BE OPENED. EXCEPTION: A MECHANICAL VENTILATION SYSTEM CAN BE PROVIDED WITH A MINIMUM VENTILATION RATE OF 50 CUBIC FEET PER MINUTE FOR INTERMITTENT VENTILATION 2. BATHROOM FAN SHALL VENT DIRECTLY OUTSIDE WITH MAX RATING 3.0 SONES 3. EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. EXHAUST FANS NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE 4. PROVIDE BACKDRAFT DAMPERS ON KITCHEN HOOD, DRYER VENT AND ALL EXHAUST FANS 5. MINIMUM 180 CFM KITCHEN HOOD FOR ELECTRICAL STOVE. EXHAUST TO EXTERIOR WITH METAL DUCT WORK. A CEILING OR WALL EXHAUST MAY BE USED THAT PROVIDES 5 AIR CHANGES PER HOUR ELECTRICAL 1. SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A 10-YEAR LIFE BATTERY BACKUP. A SMOKE DETECTOR SHALL BE PROVIDED IN EACH SLEEPING ROOM. SMOKE DETECTORS SHALL BE INTERCONNECTED AND SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS. ALL SMOKE DETECTORS SHALL BE PHOTOELECTRIC SMOKE ALARMS 2. CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED 3. ALL LIGHTING SHALL BE HIGH EFFICACY LUMINARIES. PROVIDE ONE LIGHT CIRCUIT FOR EACH 500 SF OF LIVING AREA. MINIMUM LIGHTING IS REQUIRED FOR LANDING, STEPS, DECK PER CODE, 1-FOOT CANDLE. 4. ALL 125V, 15A AND 20A RECEPTACLES SHALL BE LISTED AS TAMPER RESISTANT 5. ALL BRANCH CIRCUITS THAT SUPPLY 125V, SINGLE PHASE, 15A AND 20A OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER (AFCI) COMBINATION TYPE LISTED TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT 6. BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY A MINIMUM OF ONE 20A BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS FROM OTHER ROOMS CONNECTED BUT MAY SERVE MORE THAN ONE BATHROOM. RECEPTACLES SHALL NOT BE INSTALLED DIRECTLY OVER A BATHTUB OR SHOWER. ALL BATHROOM OUTLETS MUST BE GFI PROTECTED. PROVIDE AT LEAST ONE OUTLET WITHIN 36" OF THE OUTSIDE EDGE OF EACH BATHROOM SINK BASIN 7. WALL SPACES 24" AND WIDER SHALL HAVE A RECEPTACLE EVERY 12'0". HALLWAYS OF 10' LENGTH OR MORE REQUIRE AT LEAST ONE RECEPTACLE N MECHANICAL, ELECTRICAL AND PLUMBING PLAN NEW DETACHED ADU 2039 N VICTORIA DR UNIT #2 SANTA ANA, CA, 92706 24-1055 9/13/2024 1/4" = 1'-0" A108 Jeffrey Schaefer, P.E. (562) 850-1223 License Number - C91734 Expiration Date - Dec 31, 2026 3325 E 4th St. Long Beach, CA 90814 34" Wide Fridge A B C 1 2 3 4X8 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X8 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 4X6 BEAM 1 2 3 A B C 4X6 BEAM 4X6 BEAM S CO WP LEGEND SYMBOL DESCRIPTION=SYMBOL DESCRIPTION= = = = = = = = = = = = = = = = = = = = = = = CO S SMOKE ALARM CARBON MONOXIDE ALARM REVISION DESIGNATION N NORTH ARROW S SWITCH OUTLET, AFCI PROTECTED WP WEATHER PROOF OUTLET1 50 CFM EXHAUST FAN WHOLE HOUSE FAN 1. EXTERIOR RECEPTACLES SHALL BE ON AFCI, GFCI, WR, AND W.P. WITH A BUBBLE COVER. WALL SCONCE LIGHT RECESSED CAN LIGHT WALL MOUNTED FIXTURE DIRECTIONAL RECESSED CAN LIGHT (N) 30,000 BTU CONDENSER (N) 200-AMP PANEL TO SERVICE ADU WITH 40 AMP BACK-FEED PROTECTION FOR SOLAR. 180 CFM EXHAUST HOOD FOR ELECTRIC STOVE. VENT TO OUTSIDE WITH BACKDRAFT LOUVER (N) HEAT PUMP WATER HEATER. WP WP WP WP SS S S S 3-way S 3-way S S S S 3-way SWITCH TO CONTROL GARBAGE DISPOSAL SWITCH TO CONTROL UNDERMOUNT CABINET LIGHTING AIR HANDLER UNIT IN ATTIC. DUCTS TO RUN THROUGH BATHROOM / STORAGE CLOSET / STUDIO SPACE SS S S 16X18 CLG RETURN G/AFCIG/AFCI G/AFCI G/AFCI G/ A F C I G/AFCI 4" SEWER LINE FOR ADU TO STREET 1" WATER LINE FOR ADU TO STREET WATER HEATER W/D 240V 24 0 V 240V 24X42 SKY 24X42 SKY 24X42 SKY 24X42 SKY 24X42 SKY 24X42 SKY 50 CFM BATHROOM FAN (DIRECT VENT) TO OPERATE CONTINUOUSLY TO COMPLY WITH WHOLE-BUILDING VENTILATION (MIN 44 CFM IAQ PER TITLE 24) S CO 11'-1 0 " G/AFCI G/AFCI VACANCY SENSOR VACANCY SENSOR DIMMER SWITCH (EXTERIOR LIGHTS)DIMMER SWITCH DIMMER SWITCH DIMMER SWITCH (BEDROOM LIGHTS) 3-wa y 3-way 3-way G/AFCI G/ A F C I 2039 N Victoria Drive #24/28/2025 November 8, 2024 Project No. 24-8009 Michael Sitton 2039 N Victoria Dr Santa Ana, CA. 92706 Subject: Geotechnical Investigation Report, Proposed ADU and Spa, 2039 N. Victoria Drive, Santa Ana, California 92706. Michael, In accordance with your request and authorization, TGR Geotechnical, Inc. (TGR) has performed a geotechnical investigation for the proposed ADU and spa at the back of the residence at the subject site. This report presents the findings of our geotechnical investigation, including site seismicity and provides design geotechnical recommendations for the proposed improvement. The work was performed in accordance with our proposal dated September 13, 2024 and your subsequent authorization to proceed. The proposed improvement is suitable from a geotechnical viewpoint provided the recommendations presented in this report are incorporated during design and construction. If you have any questions regarding this report, please do not hesitate to contact this office. We appreciate this opportunity to be of service. Respectfully submitted, TGR GEOTECHNICAL, INC. Respectfully submitted, Ryan Stewart, MS Staff Geologist Sanjay Govil, PhD, PE, GE 2382 Principal Geotechnical Engineer Distribution: (1) Addressee 2039 N Victoria Drive #24/28/2025 24-8009 Page 2 Attachments Plate 1 – Boring Location Map Figure 1 – Site Location Map Figure 2 – Regional Geology Map Figure 3 – Historic High Groundwater Map Figure 4 – Regional Fault Map Figure 5 – Seismic Hazard Zone Map Appendix A – References Appendix B – Log of Borings Appendix C – Laboratory Testing Procedures and Test Results Appendix D – Seismic Design Parameters 2039 N Victoria Drive #24/28/2025 24-8009 Page 3 INTRODUCTION Site Description and Proposed Project Development The subject site is located at 2039 North Victoria Drive (Site Location Map, Figure 1), within the City of Santa Ana, California. The property consists of a two-level single-family residence with a detached garage/pool house, currently under construction. The pool house and residence are outside of the scope of this report. The site currently has footings cut in the area of the proposed ADU. It is our understanding that an ADU is proposed in the southeast corner of the yard and a spa is proposed in the northeast corner, behind the garage/pool house. Based upon conversations on the site, it is our understanding that a pool was demolished and backfilled in the rear yard in the vicinity of the proposed ADU, the limits of which are unknown at this time. We have not been provided with a depth of the pool. It is our understanding that the pool had a diving board at the northeast end, therefore depths have been assumed to be as great as ten feet or deeper in the vicinity of the proposed ADU. Scope of Work The scope of work for this geotechnical investigation included the following: • Excavation of three (3) hand auger borings to the approximate maximum depth of 15.5 feet below the existing grade to evaluate the existing soil conditions at the subject site. • Laboratory testing of selected samples for in-situ moisture and density, maximum dry density and optimum moisture content, shear, consolidation, and sulfates. • Analysis of data, including site seismicity, foundation recommendations, and spa recommendations. • Preparing this report summarizing current subsurface soil conditions, findings, and presenting our recommendations for the proposed ADU and spa. Field Investigation Field exploration was performed on October 4, 2024 by a representative from our firm who logged the hand auger borings and obtained representative samples, which were subsequently transported to the laboratory for further review and testing. The approximate locations of the borings are indicated on the enclosed Boring Location Map (Plate 1). The subsurface conditions were explored by excavation, sampling, and logging three hand auger borings. B-1 was advanced to approximately 7 feet where it encountered refusal on concrete rubble; B-2 was advanced to approximately 15.5 feet below existing grade; and B-3 was advanced to a depth of approximately 10.5 feet below existing grade. Subsequent to excavation, all borings were backfilled with cuttings. The logs of borings presenting soil conditions and descriptions are given in Appendix B. Driven samples and bulk samples of the earth materials encountered at selected intervals were recovered from the borings. The locations and depths of the soil samples recovered are indicated on the logs in Appendix B. 2039 N Victoria Drive #24/28/2025 24-8009 Page 4 Laboratory Testing Laboratory tests were performed on representative samples to verify the field classification of the recovered samples and to evaluate the geotechnical properties of the subsurface soils and bedrock. The following tests were performed: • In-situ Moisture Content (ASTM D2216) and Dry Density (ASTM D7263); • Maximum Dry Density and Optimum Moisture Content (ASTM D1557); • Direct Shear Strength (ASTM D3080); • Consolidation (ASTM D2435); • Expansion Potential (ASTM D4829); • Passing No. 200 Sieve (ASTM 1140); and • Sulfate (Cal 417). Laboratory tests for geotechnical characteristics were performed in general accordance with the ASTM procedures. The results of the in-situ moisture content and density tests are shown on the test pit logs (Appendix B). The results of the laboratory tests are presented in Appendix C. 2039 N Victoria Drive #24/28/2025 24-8009 Page 5 GEOTECHNICAL FINDINGS Regional Geologic Setting The subject site is located within the south-western corner of the Orange 7.5-Minute Quadrangle, Orange County, California. According to the Geologic Map of Orange County, California (Morton and Miller, 1981), the subject site is underlain by alluvium. Figure 2 presents the Regional Geologic Map. Groundwater Subsurface water was not encountered in our borings to the explored depth of 15.5 feet. Based on our review of available historical groundwater information (CDMG, 1997) regional groundwater is mapped at greater than 40 feet beneath the subject site. Static groundwater is not anticipated to impact the proposed improvement. Figure 3 presents the Historic High Groundwater Map. Earth Units Based on our subsurface investigation, the location of the proposed ADU (B-1 and B-2) is underlain by fill generally consisting of greyish brown silty sand with clay to a depth of approximately 2 to more than 7 feet, below which lies native alluvium consisting of sandy silt to silty sand to a depth of 15.5 feet, the maximum depth explored. In the area of the proposed spa (B-3), the native alluvium consisting of sandy silt to silty sand was observed at the surface and continued to a depth of approximately 10.5 feet. Detailed descriptions of the earth units encountered in our borings are presented in the log of borings. Faulting and Seismicity The subject site, like the rest of Southern California, is located within a seismically active region as a result of being located near the active margin between the North American and Pacific tectonic plates. The principal source of seismic activity is movement along the northwest- trending regional faults such as the San Andreas, San Jacinto and Elsinore fault zones. These fault systems produce approximately 5 to 35 millimeters per year of slip between the plates. We consider the most significant geologic hazard to be the potential for moderate to strong seismic shaking that is likely to occur at the subject site. The subject site is located in the highly seismic Southern California region within the influence of several faults that are considered to be Holocene-active or pre-Holocene faults. A Holocene-active fault is defined by the State of California as a fault that has exhibited surface displacement within the Holocene time (about the last 11,700 years). A pre-Holocene fault is defined by the State as a fault whose history of past movement is older than 11,700 years ago and does not meet the criteria for a Holocene-active fault. These Holocene-active and pre-Holocene faults are capable of producing potentially damaging seismic shaking at the site. It is anticipated that the subject site will periodically experience ground acceleration as the result of small to moderate magnitude earthquakes. Other active faults without surface expression (blind faults) or other potentially active seismic sources that are not currently zoned and may be capable of generating an earthquake are known to be present under in the region. 2039 N Victoria Drive #24/28/2025 24-8009 Page 6 The subject site is not included within any Earthquake Fault Zones as created by the Alquist- Priolo Earthquake Fault Zoning Act (CGS, 2018). Our review of geologic literature pertaining to the site area indicates that there are no known active or potentially active faults located within or immediately adjacent to the subject property. The nearest active fault is the Peralta Hills Fault which is approximately 5.1 miles northeast of the site. The next nearest faults are Bolsa Fairview Fault which is approximately 7.4 miles southwest of the site, the Yorktown Fault which is approximately 7.7 miles southwest of the site, the Adams Avenue Fault which is approximately 8.7 miles southwest of the site, and the North Branch Fault which is approximately 9.7 miles southwest of the site. The regional fault map, Figure 4, shows the location of the subject site in respect to the regional faults. Surface Fault Rupture and Ground Shaking Since no known faults are located within the site, surface fault rupture is not anticipated. However, due to the close proximity of known active and potentially active faults, severe ground shaking should be expected during the life of the proposed structures. Liquefaction Liquefaction is a seismic phenomenon in which loose, saturated, fine-grained granular soils behave similarly to a fluid when subjected to high-intensity ground shaking. Liquefaction occurs when these ground conditions exist: 1) Shallow groundwater; 2) Low density, fine, clean sandy soils; and 3) High-intensity ground motion. Effects of liquefaction can include sand boils, settlement, and bearing capacity failures below foundations. A review of the seismic hazard zone map of the Orange Quadrangle indicates that the subject site is not located within an area having a potential for earthquake induced liquefaction (Figure 5). Based on the above and the absence of shallow groundwater, the potential for liquefaction at the subject site is considered to be low. Seismically Induced Settlement Ground accelerations generated from a seismic event can produce settlements in sands or in granular earth materials both above and below the groundwater table. This phenomenon is often referred to as seismic settlement and is most common in relatively clean sands, although it can also occur in other soil materials. Based on the nature of the soils underlying the site the potential for seismically induced settlement is considered low. Lateral Spreading Seismically induced lateral spreading involves primarily movement of earth materials due to earth shaking. Lateral spreading is demonstrated by near-vertical cracks with predominantly horizontal movement of the soil mass involved. Based on the nature of the soils underlying the site and the generally flat lying topography the potential for lateral spreading at the subject site is considered very low. Earthquake Induced Landsliding Landsliding involves downhill motion of earth materials during or subsequent to earth shaking. Historically, landslides triggered by earthquakes have been a significant cause of damage. Areas that are most susceptible to earthquake induced landslides are areas with steep slopes in 2039 N Victoria Drive #24/28/2025 24-8009 Page 7 poorly cemented or highly fractured bedrock, areas underlain by loose, weak soils, and areas on or adjacent to existing landslide deposits. The property is in a flat lying area and the site is not within a mapped zone of earthquake- induced landsliding (Figure 5). DISCUSSIONS AND CONCLUSIONS General Based on our field exploration, laboratory testing, and geotechnical engineering analysis, the proposed improvement is considered suitable from a geotechnical viewpoint, provided the recommendations contained in this report are incorporated into the design and construction phases of the project. Conclusions Based on our findings and analyses, the subject site is likely to be subjected to moderate to severe ground shaking due to the proximity of known active and potentially active faults. This may reasonably be expected during the life of the structure and should be designed accordingly. The primary conditions affecting the proposed project site development are as follows: • Presence of undocumented fill (in excess of 7 feet) • High settlement in the vicinity of the proposed spa The engineering evaluation performed concerning site preparation and the recommendations presented are based on information provided to us and obtained by us during our office and field work. This report is prepared for the proposed deck replacement within the subject site. In the event that any significant changes are made to the proposed development, the conclusions and recommendations contained in this report shall not be considered valid unless the changes are reviewed, and the recommendations of this report are verified or modified in writing by TGR. 2039 N Victoria Drive #24/28/2025 24-8009 Page 8 RECOMMENDATIONS Seismic Design Parameters When reviewing the 2022 CBC the following parameters should be incorporated into the design. The Site Class is based on site soil conditions per Section 11.4.3 of the ASCE 7-16. It is our opinion Site Class D - Default is the most appropriate based on site soil conditions. Parameter Value Latitude (degree) 33.7640 Longitude (degree) -117.8708 Site Class (ASCE 7-16 Section 11.4.3) D–Default Site Coefficient, Fa (CBC Table 1613A.2.3 (1)) 1.2 Site Coefficient, Fv (CBC Table 1613A.2.3 (1)) 1.8 Mapped Spectral Acceleration at 0.2-sec Period, Ss 1613A.2.1) 1.319 g Mapped Spectral Acceleration at 1.0-sec Period, S1 1613A.2.1) 0.47 g Spectral Acceleration at 0.2-sec Period Adjusted for Site Class, SMS (CBC Section 1613A.2.3) 1.583 g Spectral Acceleration at 1.0-sec Period Adjusted for Site Class, SM1 (CBC Section 1613A.2.3) 0.846 g Design Spectral Acceleration at 0.2-sec Period, SDS 1613A.2.4) 1.055 g Design Spectral Acceleration at 1.0-sec Period, SD1 1613A.2.4) 0.564 g Seismic Response Coefficient (Cs) ASCE 7-16 Per 12.8-6 Mapped MCEG, Peak Ground Acceleration, PGA 0.556 g Site Coefficient for Mapped MCEG, FPGA 1.2 Site Modified Peak Ground Acceleration, PGAM 0.667 g In general, ASCE 7-16 Section 11.4.8 requires site-specific hazard analysis for structures on Site Class D for values of S1 greater than or equal to 0.2 g. When using Equivalent lateral Force (ELF) and Modal Response Spectrum Analysis (MRSA), the ASCE 7-16 Section 11.4.8 Item 1 exception shall be utilized. Increasing SM1 by 50% in Eq. (11.4-2) results in an increase in the value of SD1 determined by Eq. (11.4-4) by 50%. These increased values of SM1 and SD1 are to be used for all applications of these parameters throughout the Standard, including for formulation of the design response spectrum where a design response spectrum is needed per this standard. It should be noted that the 50% increase in SD1 also increases Ts by 50% resulting in an extension of the acceleration-controlled plateau of the design response spectrum. Cs is determined in accordance with Eq. (12.8-6). 2039 N Victoria Drive #24/28/2025 24-8009 Page 9 Conformance to the criteria presented in the above table for seismic design does not constitute any type of guarantee or assurance that significant structural damage or ground failure will not occur during a large earthquake event. The intent of the code is “life safety” and not to completely prevent damage of the structure, since such design may be economically prohibitive. Foundation Design Recommendations The proposed ADU may be supported on continuous and/or spread footings. Bearing capacity recommendations for shallow foundations are presented below. An allowable bearing pressure of 2000 pounds per square foot may be used in the design. These recommendations assume that footings will be supported on a minimum of three (3) feet of engineered fill. However, deeper fill (as much as 10 feet) may be required due to the presence of the demolished pool, as shown in Plate 1. The minimum recommended footing depth is 24-inches below the lowest adjacent grade. The minimum recommended footing width is 18 inches for continuous footing and twenty-four (24) inches for pad footings. A minimum reinforcement of 2-No.4 steel bars top and bottom is required for continuous footings from a geotechnical viewpoint. Foundation design details such as concrete strength, reinforcements, etc should be established by the Structural Engineer. A one-third (1/3) increase on the aforementioned bearing pressure may be used in design for short-term wind or seismic loads. The static total and differential settlements between adjacent footings supported on competent bedrock are not anticipated to exceed one (1) inch and one-half (0.5) inch over 30 feet, respectively. All footings should meet the setback requirements presented in 2022 CBC. Resistance to lateral loads can be assumed to be provided by passive earth pressure and by friction acting on structural components in permanent contact with the subgrade soils. Lateral resistance on the sides of footings may be computed using a passive pressure of 200 pounds per square foot per foot of embedment, subject to a maximum of 2000 pounds per square foot. An allowable friction coefficient of 0.30 may be assumed with dead load forces between concrete and the supporting soils. Passive pressure and frictional resistance could be combined in determining the total lateral pressure resistance, provided one of them is reduce by 50%. Drilled Piers Alternatively, the proposed ADU may be supported on drilled piers embedded a minimum of 10 feet into competent native soils with a structural floor. The recommended minimum pier diameter is 24-inches. The drilled piers may be designed for an allowable frictional resistance of 200 pounds per square foot for competent native. The uplift capacity may be taken as one-half of downward capacity plus the weight of the caisson. The lateral capacity may be taken as 200 pounds per square foot per foot of depth (maximum 2,000 psf). The caisson capacity within the 2039 N Victoria Drive #24/28/2025 24-8009 Page 10 undocumented fill shall be ignored. As a minimum the caisson capacity (axial and lateral) shall be ignored in the upper 10 feet. The above values may be increased by one-third when considering short duration seismic or wind loads. Foundation design details such as concrete strength, reinforcements, etc. should be established by the Structural Engineer. The total settlement is not expected to exceed ½ inch. The differential settlement between piers is estimated as ¼ inch. For caissons spaced at less than three (3) diameters on center, additional group capacity reduction effects should be taken into account on evaluating the allowable axial capacity of the pile groups. The drilling and installation of caissons should be performed under the observation of TGR Geotechnical. Precautions should be taken during installation of caissons. The caisson excavation should be filled with concrete as soon as possible after the drilling is completed. The excavation should not be left open overnight. The concrete should not be allowed to fall freely more than five (5) feet; vibration should take place throughout the full length of the pile to eliminate voids in either the pile base or the shaft. Placement procedure such as tremie, should ensure that aggregate segregation does not occur. Where pile spacing is less than three (3) diameters, caissons should be drilled and filled alternately, allowing the previously poured pile concrete to set for at least twenty-four (24) hours, or as permitted by the geotechnical engineer. Slab-on-Grade Design Slab-on-Grade which will receive relatively light loads on low expansive soils should be a minimum of 5-inches thick, underlain by 4-inches of crushed aggregate base (CAB) and reinforced with a minimum of No. 4 reinforcing bars on 18-inch centers in two horizontally perpendicular directions. Reinforcing should be properly supported to ensure placement near the vertical midpoint of the slab. "Hooking" of the reinforcement is not considered an acceptable method of positioning the steel. The subgrade material should be compacted to a minimum of ninety (90) percent of the maximum laboratory dry density (ASTM D1557) to a minimum depth of three (3) feet or the bottom of undocumented fill (whichever is deeper). Prior to placement of concrete, the subgrade soils should be moistened to optimum moisture content and verified by our field representative. For moisture sensitive flooring, the floor slab should be underlain by a minimum 15-mil impermeable polyethylene membrane (Stego Wrap, Moistop Plus, or any equivalent meeting the requirements of ASTM D1745) as a capillary break. The polyethylene membrane joints should be lapped not less than 6 inches. Sand may be placed above and below the impermeable polyethylene membrane at the discretion of the project structural engineer/concrete contractor for proper curing and finish of the concrete slab-on-grade and protection of the membrane and is considered outside the scope of geotechnical engineering. 2039 N Victoria Drive #24/28/2025 24-8009 Page 11 Cement Type and Corrosion Based on laboratory testing concrete used should be designed in accordance with the provisions of ACI 318-19, Chapter 19 for Exposure Class S0 with a minimum unconfined compressive strength of 2,500 psi, per ACI 318-19 Table 19.3.1.1. Spa Recommendations The proposed spa shall be supported on a minimum of three (3) feet of engineered fill. Provided below are general design, construction and inspection recommendations for spa: 1. Free standing spa walls shall be designed for an equivalent fluid pressure of 65 lbs./cu.ft. When the spa is empty the walls should be designed for an active earth pressure of 60 pcf. 2. The spa should be designed to accommodate up to 1/2-inch of future total settlement and 1/4-inch differential settlement over 30 feet. 3. Where the spa is planned near any structure, appropriate surcharge loads need to be incorporated into design and construction. 4. Hydrostatic pressure relief valves may be incorporated into the spa design. 5. All fittings and pipe joints, particularly fittings in the side of the spa, should be properly sealed to prevent water from leaking into the adjacent soil materials. 6. An elastic expansion joint (waterproof sealant) should be installed to prevent water from seeping into the soil at all deck joints. 7. The design engineer and/or contractor should determine joint and saw cut locations for the spa deck. However, spacing should not exceed 8 feet. 8. It is imperative that the homeowner incorporate into the overall improvement scheme adequate provisions for surface drainage. Ponding water, ground saturation and flows over slope faces are all situations that must be avoided. 9. All deck slabs should be minimally reinforced with No. 4 steel bar at 18-inch on center both ways. All slab reinforcement should be supported to ensure proper mid-slab positioning during placement of concrete. 10. Deck should have a minimum thickness of four inches with the perimeter edge thickened. The thickened edge shall have minimum 18-inch embedment. 11. Spa shall be founded on a minimum of 3 feet of engineered fill. An allowable bearing pressure of 1800 pounds per square foot may be used in the design. 12. A one-third (1/3) increase on the aforementioned bearing pressure may be used in design for short-term wind or seismic loads. 13. An allowable coefficient of friction between soil and concrete of 0.38 may be used with the dead load forces. 2039 N Victoria Drive #24/28/2025 24-8009 Page 12 Site Development Recommendations General During earthwork construction, all site preparation and the general procedures of the contractor should be observed, and the fill selectively tested by a representative of TGR. If unusual or unexpected conditions are exposed in the field, they should be reviewed by this office and if warranted, modified and/or additional recommendations will be offered. Grading All grading should conform to the guidelines presented in the California Building Code (2022 edition), except where specifically superseded in the text of this report. Prior to grading, TGR’s representative should be present at the pre-construction meeting to provide grading guidelines, if needed, and review any earthwork. The upper 2 to approximately 10 feet of soils within the area of the proposed ADU are undocumented fill. Undocumented fill is considered unsuitable for the support of engineered fill and/or structures and shall be removed. Undocumented fill related to the previously demolished pool is anticipated under the proposed building pad and shown on Plate 1. Deeper removals may be required where excavation bottoms expose unsuitable soils. Removals shall be a minimum of 3 feet below the bottom for footings or bottom of the old pool (varies, up to 10 feet or greater), whichever is deeper. Site soils may be reused as engineered fill provided they are free of oversized particles and the recommendations presented in this report are implemented. Exposed bottoms should be scarified a minimum of 6-inches, moisture conditioned to optimum moisture and compacted to a minimum ninety (90) percent relative compaction. Subsequently, site fill soils should be re- compacted to a minimum of ninety (90) percent relative compaction at optimum moisture content. The lateral extent of removals beyond the building/structure/footing limits should be equal to at least 7 feet. The depth of over-excavation should be reviewed by the Geotechnical Consultant during the actual construction. Any subsurface obstruction buried structural elements, and unsuitable material encountered during grading, should be immediately brought to the attention of the Geotechnical Consultant for proper exposure, removal and processing, as recommended. Fill Placement Prior to any fill placement TGR should observe the exposed surface soils. The site soils may be re-used as engineered fill provided they are free of organic content and particle size greater than 4-inches. All particles greater than 4-inches shall be removed and disposed offsite. Fill shall be moisture-conditioned to optimum moisture content and compacted to a minimum relative compaction of 90 percent in accordance with ASTM D1557. Any import soils shall be non-expansive and approved by TGR Geotechnical Inc. 2039 N Victoria Drive #24/28/2025 24-8009 Page 13 Compaction Prior to fill placement, the exposed surface should be scarified to a minimum depth of six (6) inches, fill placed in six (6) inch loose lifts, moisture conditioned to optimum moisture content, and compacted to a minimum relative compaction of ninety (90) percent in accordance with ASTM D 1557. Trenching All excavations should conform to CAL-OSHA and local safety codes. Drainage Positive site drainage should be maintained at all times. Water should be directed away from foundations and not allowed to pond and/or seep into the ground. Pad drainage should be directed toward the street/parking or other approved area. Roof gutters and down spouts should be utilized to control roof drainage. Down spouts should outlet a minimum of 5 feet from the proposed structure or into an approved subsurface drainage system. We would recommend that any proposed open-bottom planters adjacent to proposed structures be eliminated for a minimum distance of 10 feet. As an alternative, closed-bottom type planters could be utilized. An outlet placed in the bottom of the planter could be installed to direct drainage away from structures or any exterior concrete flatwork. All site drainage shall comply with the 2022 California Building Code. Utility Trench Backfill All utility trench backfill in structural areas and beneath hardscape features should be brought to optimum moisture content and compacted to a minimum relative compaction of 90 percent of the laboratory standard. Flooding/jetting is not recommended. Sand backfill, (unless trench excavation material), should not be allowed in parallel exterior trenches adjacent to and within an area extending below a 1:1 plane projected from the outside bottom edge of the footing. All trench excavations should minimally conform to CAL-OSHA and local safety codes. Soil generated from utility trench excavations may be used provided it is moisture conditioned to optimum moisture content and compacted to 90 percent minimum relative compaction. Temporary Excavation Recommendations In areas not adjacent to existing structures or property lines, soils may be cut vertically to a depth of approximately four (4) feet below adjacent grade. Excavations deeper than 4 feet should be temporarily shored or sloped back to at least 1H:1V or flatter for the entire excavation. The exposed slope face should be kept moist (but not saturated) during construction to reduce local sloughing. No surcharge loads should be permitted within a horizontal distance equal to the height of cut from the toe of excavation unless the cut is properly shored. Temporary excavation that extends below an imaginary plane inclined at 45 degrees from the property line or below the edge of adjacent existing footings will require shoring. Temporary Shoring Temporary shoring may be required for those excavations where temporary slope cuts as specified above are not feasible. Temporary cantilever shoring should be designed to resist an active earth pressure of 35 pounds per cubic foot equivalent fluid pressure for level conditions behind shoring. The design of shoring should also include surcharge-loading effects of existing 2039 N Victoria Drive #24/28/2025 24-8009 Page 14 structures and anticipated traffic, including construction equipment, when loading is within a distance from the shoring equal to the depth of excavation. All excavations should conform to CAL-OSHA and local safety codes. The stability of temporary excavation is the responsibility of the contractor. However, as a minimum the lateral movement at the top of the shoring soldier piles should be monitored. Lateral deflection of 0.5 inches or more shall be brought to the attention of TGR with remedial measures. If lateral deflection exceeds 1.0-inch, work shall stop, and mitigation measures taken prior to continuing work. TGR should be present to observe the excavation to provide additional recommendations as considered necessary depending on the exposed condition. Soldier piles shall have a minimum diameter of eighteen (18) and shall be spaced at least two diameters on centers, a lateral passive resistance of 250 psf/ft of embedment depth into competent alluvium with a maximum lateral passive resistance of 2,500 psf should be used in design. The minimum recommended embedment is 10 feet into competent alluvium. The point of fixity may be taken as 2 feet below proposed excavation bottom. The shoring design engineer may utilize this passive pressure over one to two pile diameters at their discretion/design procedure. The shoring design engineer is however responsible for the performance of the shoring system. Soldier pile members placed in drilled holes should be properly backfilled with sand/cement slurry or lean concrete in order to develop the required passive resistance. The lagging between the soldier piles may be designed for a maximum nominal pressure of 400 psf, and should consist of wood members, or solid plywood or steel sheets. All excavations should conform to CAL-OSHA and local safety codes. Geotechnical Observation/Testing During Construction Per sections 1705.6 and table 1705.6 of the 2022 California Building Code, periodic special inspection shall be performed to: • Verify materials below shallow foundations are adequate to achieve the design bearing capacity; • Verify excavations are extended to the proper depth and have reached proper material; • Verify classification and test compacted materials; and • Prior to placement of compacted fill, inspect subgrade and verify that the site has been prepared properly Per sections 1705.6 and table 1705.6 of the 2022 California Building Code, continuous special inspection shall be performed to: • Verify use of proper materials, densities and lift thickness during placement and compaction of compacted fill. The geotechnical consultant should perform observation and/or testing at the following stages: • During any grading and fill placement; • Prior to pouring foundation or flatwork concrete; • During trench excavation; • Excavation bottom; • Placement of bedding material; 2039 N Victoria Drive #24/28/2025 24-8009 Page 15 • During trench backfill; • Subgrade for flatwork; • When any unusual soil conditions are encountered during any construction operation subsequent to issuance of this report. Limitations This report was prepared for a specific client and a specific project, based on the client’s needs, directions and requirements at the time. This report was necessarily based in part upon data obtained from a limited number of observances, site visits, soil and/or other samples, tests, analyses, histories of occurrences, spaced subsurface exploration and limited information on historical events and observations. Such information is necessarily incomplete. Variations can be experienced within small distances and under various climatic conditions. Changes in subsurface conditions can and do occur over time. This report is not authorized for use by and is not to be relied upon by any party except the client with whom TGR contracted for the work. Use or reliance on this report by any other party is that party’s sole risk. Unauthorized use of or reliance on this report constitutes and agreement to defend and indemnify TGR from and against any liability which may arise as a result of such use or reliance, regardless of any fault, negligence, or strict liability of TGR. 2039 N Victoria Drive #24/28/2025 PLATE 1 BORING LOCATION MAP2039 NORTH VICTORIA DRIVESANTA ANA, CALIFORNIA PROJECT NO.: 24-8009 10’ 0’ 10’ 20’ 30’ B-1 B-2 B-3 B-3 APPROXIMATE LOCATION OF BORING Approximate Limits of Demolished Pool 5’ 10’ 10’APPROXIMATE DEPTH OF ANTICIPATED REMOVAL 2039 N Victoria Drive #24/28/2025 SITE LOCATION MAP2039 NORTH VICTORIA DRIVESANTA ANA, CALIFORNIA PROJECT NO.: 24-8009 FIGURE 1 .25 0 .25 .5 .75 SITE (miles) 2039 N Victoria Drive #24/28/2025 Morton, P.K., and Miller, R.V., 1981, Geologic map of Orange County, California, showing mines and mineral deposits: California Division of Mines and Geology, Bulletin B-204, scale 1:48,000 REGIONAL GEOLOGY MAP2039 NORTH VICTORIA DRIVESANTA ANA, CALIFORNIA FIGURE 2 PROJECT NO.: 24-8009 SITE 2000’ 0’ 2000’ 4000’ 6000’ 2039 N Victoria Drive #24/28/2025 Modified From: California Department of Conservation, Division of Mines and Geology, 1997, Seismic Hazard Zone Report for the Orange 7.5- Minute Quadrangle, Orange County, California, Seismic Hazard Zone Report 011. FIGURE 3 HISTORIC HIGH GROUNDWATER MAP2039 NORTH VICTORIA DRIVESANTA ANA, CALIFORNIA PROJECT NO.: 24-8009 1000’ 0’ 1000’ 2000’ 3000’ SITE 2039 N Victoria Drive #24/28/2025 REGIONAL FAULT MAP2039 NORTH VICTORIA DRIVESANTA ANA, CALIFORNIA FIGURE 4 Modified From: Jennings, C. W., 2010, Fault Activity Map of California and Adjacent Areas, California Division of Mines and Geology, Geologic Data Map Series, No. 6, Scale 1:750,000. SITE PROJECT NO.: 24-8009 2 0 2 4 6 (miles) 2039 N Victoria Drive #24/28/2025 FIGURE 5 SEISMIC HAZARD ZONE MAP2039 NORTH VICTORIA DRIVESANTA ANA, CALIFORNIA Modified From: California Geological Survey, Earthquake Zones of Required Investigation, Orange Quadrangle, dated April 15, 1998. PROJECT NO.: 24-8009 SITE 1000’ 0’ 1000’ 2000’ 3000’ 2039 N Victoria Drive #24/28/2025 24-8009 Page i APPENDIX A REFERENCES 2039 N Victoria Drive #24/28/2025 24-8009 Page ii APPENDIX A References AEH Design, Inc., 2024, Sitton Residence, Interior Remodel, 2039 North Victoria Drive, Santa Ana, CA, 92706, dated 9-20-22, last revision 6-16-24. California Department of Conversation – California Geological Survey, 2018, Earthquake Fault Zones, A Guide for Government Agencies, Property Owners/Developers and Geoscience Practitioners for Assessing Fault Rupture Hazards in California, Special Publication 42. California Geological Survey, 2010, Fault Activity Map of California, Geologic Data Map No. 6. California Department of Conservation – Division of Mines and Geology, 1998, Maps of Known Active Fault Near – Source Zones in California and Adjacent Portions of Nevada. California, State of, Department of Conservation, Division of Mines and Geology, 2008, Guidelines for Evaluating and Mitigating Seismic Hazards in California, CDMG Special Publication 117A. California Department of Conservation – Division of Mines and Geology, 1997, Seismic Hazard Zone Report for the Orange 7.5-Minute Quadrangle, Orange County, California, Report 011. California Geological Survey, Earthquake Zones of Required Investigation, Orange Quadrangle, dated April 15, 1998 Fault Activity Map of California, 2010, California Geological Survey, Geologic Data Map No. 6 Compilation and Interpretation by: Charles W. Jennings and William A. Bryant, Graphics by: Milind Patel, Ellen Sander, Jim Thompson, Barbara Wanish and Milton Fonseca International Code Council, 2022, California Building Code, Title 24, Part 1 and 2. 2039 N Victoria Drive #24/28/2025 24-8009 Page iii APPENDIX B LOG OF BORINGS 2039 N Victoria Drive #24/28/2025 Project Number: Project Name: Date Drilled: Ground Elev: Mo i s t u r e Co n t e n t ( % ) RS SG Hand Auger 140lbs / 30in LOG OF EXPLORATORY BORING B-1 Ot h e r Te s t s PLATE 1This Boring Log should be evaluated in conjunction with the complete geotechnical report. This Boring Log represents conditions observed at the specific location and date indicated, it is not warranted to be representative of subsurface conditions at other locations and times. SUMMARY OF SUBSURFACE CONDITIONS Dr y D e n s i t y , (p c f ) 1 109 LAB RESULTS Sandy clay to clayey sand, reddish brown to black, moist. 119 11 10 @ ~2.5 feet solid block of (assumed) concrete was encountered, started new boring approximately 1 foot away. Second attempt terminated on similar. Clayey sand, black, slightly moist, crumbly, concrete pieces throughout. Total Depth: 7 feet. Boring terminated on refusal in concrete debris. No caving observed. No groundwater observed. Borings backfilled with soil cuttings upon completion. Logged By: Project Engineer: Drill Type: Drive Wt & Drop: ofSheet1 Fill: Silty sand, greyish brown, slightly moist, fragments of concrete, brick, cans, etc. FIELD RESULTS 24-8009 Victoria Drive, Santa Ana 10/4/24 - 10/4/24 US C S De p t h (f t ) SP T b l o w s / f t (o r e q u i v a l e n t N ) Gr a p h i c L o g Modified California LO G O F B O R I N G 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 1 / 8 / 2 4 Water Table ATD 5 10 15 Standard Split Spoon No recovery Dr i v e S a m p l e Bu l k S a m p l e Po c k e t P e n (t s f ) Shelby Tube 2039 N Victoria Drive #24/28/2025 LOG OF EXPLORATORY BORING B-2 Total Depth: 15.5 feet. No caving observed. No groundwater observed. Borings backfilled with soil cuttings upon completion. Logged By: Project Engineer: Drill Type: Drive Wt & Drop: ofSheet1 1 SUMMARY OF SUBSURFACE CONDITIONS ... same as above Ot h e r Te s t s PLATE 2 EI, SO4, Max, Shear This Boring Log should be evaluated in conjunction with the complete geotechnical report. This Boring Log represents conditions observed at the specific location and date indicated, it is not warranted to be representative of subsurface conditions at other locations and times. Dr y D e n s i t y , (p c f ) Project Number: Project Name: Date Drilled: Ground Elev: RS SG Hand Auger 140lbs / 30in -200= 52% , consol 92 112 107 100 119 9 10 13 14 ... same as above ... same as above Fill: Silty sand with clay, greyish brown, slightly moist. Native: Sandy silt to silty sand, slightly moist to moist with depth, medium dense. Minor changes in sand/silt composition with depth ... same as above more silt, slightly moist ... same as above, moist 12 5 10 15 SP T b l o w s / f t (o r e q u i v a l e n t N ) Gr a p h i c L o g FIELD RESULTS De p t h (f t ) US C S Water Table ATD LAB RESULTS Mo i s t u r e Co n t e n t ( % ) 24-8009 Victoria Drive, Santa Ana 10/4/24 - 10/4/24 Po c k e t P e n (t s f ) LO G O F B O R I N G 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 1 / 8 / 2 4 Bu l k S a m p l e Shelby Tube Standard Split Spoon Modified California No recovery Dr i v e S a m p l e 2039 N Victoria Drive #24/28/2025 This Boring Log should be evaluated in conjunction with the complete geotechnical report. This Boring Log represents conditions observed at the specific location and date indicated, it is not warranted to be representative of subsurface conditions at other locations and times. Sheet 1 1 SUMMARY OF SUBSURFACE CONDITIONS RS SG Hand Auger 140lbs / 30in LOG OF EXPLORATORY BORING B-3 Ot h e r Te s t s LAB RESULTS Dr y D e n s i t y , (p c f ) Project Number: Project Name: Date Drilled: Ground Elev: consol PLATE 3 consol 100 108 106 100 9 7 6 6 of Logged By: Project Engineer: Drill Type: Drive Wt & Drop: Native: Sandy silt to silty sand, light brown, slightly moist to moist with depth, medium dense to dense with depth. Minor changes in sand/silt composition with depth ... same as above, moist ... same as above, slightly moist, dense ... same as above ... same as above ... same as above, medium dense Total Depth: 10.5 feet. No caving observed. No groundwater observed. Borings backfilled with soil cuttings upon completion. De p t h (f t ) 5 10 15 Gr a p h i c L o g FIELD RESULTS SP T b l o w s / f t (o r e q u i v a l e n t N ) US C S Modified California Water Table ATD Po c k e t P e n (t s f ) Standard Split Spoon LO G O F B O R I N G 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 1 / 8 / 2 4 24-8009 Victoria Drive, Santa Ana 10/4/24 - 10/4/24 Shelby Tube Mo i s t u r e Co n t e n t ( % ) No recovery Dr i v e S a m p l e Bu l k S a m p l e 2039 N Victoria Drive #24/28/2025 24-8009 Page iv APPENDIX C LABORATORY TESTING PROCEDURES AND TEST RESULTS 2039 N Victoria Drive #24/28/2025 24-8009 Page v LABORATORY TESTING PROCEDURES AND TEST RESULTS In-Situ Moisture and Density Determination Tests (ASTM D2216 and D7263): Moisture content and dry density determinations were performed on relatively undisturbed samples obtained from the test pits. The results of these tests are presented in the test pits. Where applicable, only moisture content was determined from "undisturbed" or disturbed samples. Maximum Density and Optimum Moisture Content (ASTM D1557): The maximum dry density and optimum moisture content of typical materials were determined in accordance with ASTM Test Method D1557. The results of these tests are presented in the table below: Sample Location Sample Description Maximum Dry Density (pcf) Optimum Moisture Content (%) B-2 @ 0-5 feet Yellow Brown Sandy Silt 123.5 12.0 Direct Shear Tests: A direct shear test was performed on selected remolded and/or undisturbed samples, which were soaked for a minimum of 24 hours under a surcharge equal to the applied normal force during testing. After transfer of the sample to the shear box, and reloading the sample, pore pressures set up in the sample due to the transfer were allowed to dissipate for a period of approximately 1-hour prior to application of shearing force. The samples were tested under various normal loads, a motor-driven, strain-controlled, direct-shear testing apparatus at a strain rate of less than 0.001 to 0.5 inches per minute (depending upon the soil type). The test results are presented in the test data. Sample Location Sample Description Friction Angle (degrees) Apparent Cohesion (psf) B-2 @ 0-5 feet Yellow Brown Sandy Silt, Saturated (Ultimate) 26 564 Consolidation Tests (ASTM D2435): Consolidation test were performed on selected, relatively undisturbed ring samples. Samples were placed in a consolidometer and loads were applied in geometric progression. The percent consolidation for each load cycle was recorded as the ratio of the amount of vertical compression to the original 1-inch height. The consolidation pressure curves are presented in the test data. Soluble Sulfates: The soluble sulfate content of a selected sample was determined by standard geochemical methods. The test result is presented in the table below: Sample Location Sample Description Water Soluble Sulfate in Soil, (% by Weight) Sulfate Content (ppm) Potential Degree of Sulfate Attack* B-2 @ 0-5 ft Yellow Brown Sandy Silt 0.0193 193 S0 * Based on the current version of ACI 318 Building Code, Table No. 4.3.1 requirement for Concrete Exposed to Sulfate-Containing Solutions. 2039 N Victoria Drive #24/28/2025 75 130 80 85 90 95 100 105 110 115 125 135 25 120 123.5 MOISTURE-DENSITY RELATIONSHIP TEST RESULTS Test Method DR Y D E N S I T Y , p c f WATER CONTENT, % ATTERBERG LIMITS 15 2.80 2.70 2.60 PL 12.0 Source of Material Description of Material Telephone: Fax: Project Number: 24-8009 Project Name: Victoria Drive, Santa Ana US C O M P A C T I O N 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 0 / 2 1 / 2 4 Curves of 100% Saturation for Specific Gravity Equal to: ASTM D1557 Method A 0 5 10 20 B-2 0-5 feet 30 35 40 45 Yellow Brown Sandy Silt PI Optimum Water Content Maximum Dry Density PCF % LL 2039 N Victoria Drive #24/28/2025 2,000 NORMAL PRESSURE, psf SH E A R S T R E N G T H , p s f 3,5003,0002,500 4,000 2,500 0 500 1,000 500 2,000 1,500 3,000 3,500 4,000 0 1,000 1,500 B-2 Specimen Identification Telephone: Fax: Project Number: 24-8009 Project Name: Victoria Drive, Santa Ana US D I R E C T S H E A R 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 0 / 2 1 / 2 4 120-5 feet cMC% 111 Classification 564 26Yellow Brown Sandy Silt - Saturated (Ultimate) DIRECT SHEAR TEST 2039 N Victoria Drive #24/28/2025 10 12 14 16 18 4 20 8 6 0 2 0.1 Project Number: 24-8009 Project Name: Victoria Drive, Santa Ana Telephone: Fax: STRESS, Ksf 10112 ST R A I N , % MC% CONSOLIDATION TEST 1 10 100 US C O N S O L S T R A I N 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 0 / 2 1 / 2 4 5.0 ClassificationSpecimen Identification Yellow Brown Sandy SiltB-2 2039 N Victoria Drive #24/28/2025 10 12 14 16 18 4 20 8 6 0 2 0.1 Project Number: 24-8009 Project Name: Victoria Drive, Santa Ana Telephone: Fax: STRESS, Ksf 7108 ST R A I N , % MC% CONSOLIDATION TEST 1 10 100 US C O N S O L S T R A I N 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 0 / 2 4 / 2 4 5.0 ClassificationSpecimen Identification Olive Brown Sandy SiltB-3 2039 N Victoria Drive #24/28/2025 10 12 14 16 18 4 20 8 6 0 2 0.1 Project Number: 24-8009 Project Name: Victoria Drive, Santa Ana Telephone: Fax: STRESS, Ksf 6106 ST R A I N , % MC% CONSOLIDATION TEST 1 10 100 US C O N S O L S T R A I N 2 4 - 8 0 0 9 V I C T O R I A D R I V E , S A N T A A N A . G P J T G R G E O T E C H . G D T 1 0 / 2 4 / 2 4 7.5 ClassificationSpecimen Identification Olive Yellow Sandy SiltB-3 2039 N Victoria Drive #24/28/2025 2039 N Victoria Drive #24/28/2025 24-8009 Page vi APPENDIX D SEISMIC DESIGN PARAMETERS 2039 N Victoria Drive #24/28/2025 USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 24-8009 2039 N Victoria Dr, Santa Ana, CA 92706, USA Latitude, Longitude: 33.7640067, -117.8708476 Date 10/23/2024, 10:40:22 AM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.319 MCER ground motion. (for 0.2 second period) S1 0.47 MCER ground motion. (for 1.0s period) SMS 1.583 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.055 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.556 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.667 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.319 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.42 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.563 Factored deterministic acceleration value. (0.2 second) S1RT 0.47 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.508 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.647 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.556 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.929 Mapped value of the risk coefficient at short periods CR1 0.925 Mapped value of the risk coefficient at a period of 1 s CV 1.364 Vertical coefficient 10/23/24, 10:40 AM U.S. Seismic Design Maps https://www.seismicmaps.org 1/2 2039 N Victoria Drive #24/28/2025 DISCLAIMER While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. 10/23/24, 10:40 AM U.S. Seismic Design Maps https://www.seismicmaps.org 2/2 2039 N Victoria Drive #24/28/2025 SANTA ANA CITY COUNCIL Valerie Amezcua Mayor vamezcua@santa-ana.org Benjamin Vazquez Mayor Pro Tem - Ward 2 bvazquez@santa-ana.org Thai Viet Phan Ward 1 tphan@santa-ana.org Jessie Lopez Ward 3 jessielopez@santa-ana.org Phil Bacerra Ward 4 pbacerra@santa-ana.org Johnathan Ryan Hernandez Ward 5 jryanhernandez@santa-ana.org David Penaloza Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Benjamin Vazquez COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Thai Viet Phan CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall February 5, 2025 Michael Sitton 2039 N Victoria Dr. Santa Ana, CA 92706 Subject: Address Assignment for New Detached Accessory Dwelling Unit located at 2039 North Victoria Drive (APN: 399-111-12) in Santa Ana, CA Dear Michael The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for proposed detached accessory dwelling unit located at 2039 North Victoria Drive. Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 1. 2039 North Victoria Drive, Unit 2 To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714)667-2725 or by email at HJacinto@santa-ana.org. Sincerely, Heidi Jacinto Assistant Planner II Exhibit A – Address Plan 2039 N Victoria Drive #24/28/2025 Address Letter for 2039 North Victoria Drive, Unit 2 Page 2 of 2 c: Kris K Chu, Santa Ana Manager, United States Post Office Fernando Banuelos, Fountain Valley Manager, United States Post Office Yesenia Torres, Santa Ana Manager, United States Post Office Enrique Ponce, Sna-North Grand Sta Manager, United States Post Office Esthephany Treto Ramirez, Admin Supervisor, United States Post Office Chris Tuiolosega, United States Post Office Alex Alvarez, Santa Ana Postmaster, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Ted Walstrom, Santa Ana Unified School District Jeremy Cogan, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office GIS SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Arellano, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing Division Manager Rudy Rosas, Deputy Public Works Director / City Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Services Principal Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Manager Sergio Verino, Code Enforcement Principal 2039 N Victoria Drive #24/28/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU GRADING PERMIT WAIVER REQUEST THIS WAIVER SHALL BE COMPLETED BY THE LEGAL PROPERTY OWNER(S) A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Precise grading plans prepared and stamped by a registered professional engineer shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Waiver: Residential detached Accessory Dwelling Unit (ADU) projects with a total building area of 1,200 sq. feet or less may be eligible for a grading permit waiver request if all of the following conditions are met. The property owner(s) shall take full responsibility for the site drainage by signing this waiver request agreement below. In order to qualify for the grading permit waiver, the property owner(s) shall complete all sections, check appropriate boxes, and sign this waiver request. A copy of this completed checklist shall be made part of the each set of plans. If answering NO to any of the questions, a grading plan and permit shall be required. Project Property Address: 1. ☐☐The project property is NOT located on a FEMA designated flood zone (Zone A or AE). 2. ☐☐The total amount of soil being cut or filled on this project is less than 50 cubic yards. 3. ☐☐The site drainage shall be constructed such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 4. ☐☐The site drainage shall be constructed such that the drainage will not adversely affect the adjoining properties. 5. ☐☐The project plans includes a site plan that shows site drainage patterns. Grading Permit Waiver Request I/we are requesting a waiver from the standard requirements for a precise grading plan and permit for our ADU project to be constructed at the project address indicated above. In doing so, I/we accept that the design of the site drainage patterns must adhere to the minimum requirements set forth in the current building codes and the County of Orange Drainage Design Manual. By signing this waiver request: (1) I/we certify that I/we are the legal property owner(s); (2) I/we agree to take full liability for the site drainage; (3) I/we agree that the checked box conditions above are true; and (4) I/we agree to defend, indemnify, and hold harmless the City of Santa Ana, its officials, employees, and agents against any and all claims for damages and costs arising out of the site drainage at the project property. Owner Name(s): (Print) Owner Signature(s): Date: Phone Number: Notes: 1. The building official reserves the right to require a grading permit based on site conditions. 2.This grading permit waiver request does not apply to projects in the FEMA Flood Zones. 2039 N Victoria Dr Unit #2, Santa Ana CA 92706 X X X X X Michael Sitton 1/27/2025 714-654-7201 2039 N Victoria Drive #24/28/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-610 8 SFR 4 A Sanat Ana 927062039 N Victoria Dr CONSTRUCT A DETACHED 998-SF, 1-BED, 1BATH ACCESSORY DWELLING UNIT (ADU) 2996 998 3994 1 0 4 4 4 4 4 4 4 4 4 4 Michael Sitton 714-654-7201 michael3761@gmail.com 12/13/24 2039 N Victoria Drive #24/28/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City Official Requesting Review: City Reference #: __________________________ City / County: _____________________________________ Date: __________________________________ Contact Name: _____________________________________ E-Mail: __________________________________ Title: _____________________________________ Phone #: _________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ Updated: 08/30/2021 2039 N Victoria Drive #24/28/2025 Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 2039 N Victoria Drive #24/28/2025 2039 N Victoria Drive #24/28/2025 Structural Calculations Project Address: 2039 Victoria Dr, Santa Ana, CA Building Description: Detached ADU Engineer: Jeffrey Schaefer 2039 N Victoria Drive #24/28/2025 DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT SUMMARY Project Name: 2039 N Victoria Dr Governing Codes:Building Code: 2022 California Building CodeASCE: ASCE 7-22Steel: AISC 360-16Concrete: ACI 318-19Masonry: TMS 402/602-16 Page 1 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr Module Location: Vaulted Rafter - 2x10 Module Level: Roof Module Type: Roof Rafter Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 1.5 in. X 9.25 in. X 10 ft @ 24 in. Spacing Section Adequacy:56.18% Controlling Factor: Bending-Tension Module Location: Roof Ridge Beam Module Level: Roof Module Type: Roof Beam Material Type: Structural Composite Lumber Weyerhaeuser 2.2E Parallam PSL Member Dimensions: (1) 5.25 in. X 18 in. X 33.25 ft Section Adequacy:2.19% Controlling Factor: Deflection Y Module Location: Ceiling Joist Module Level: Roof Module Type: Floor Joist Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 1.5 in. X 5.5 in. X 14.75 ft @ 16 in. Spacing Section Adequacy:23.45% Controlling Factor: Deflection Y Module Location: Door Header - Supports Ridge Module Level: Roof Module Type: Roof Beam Material Type: Structural Composite Lumber Weyerhaeuser 2.2E Parallam PSL Member Dimensions: (1) 5.25 in. X 11.875 in. X 14.67 ft Section Adequacy:19.58% Controlling Factor: Bending Stress Y Module Location: Door Header - Bedroom Module Level: Roof Module Type: Roof Beam Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 5.5 in. X 7.5 in. X 10.25 ft Section Adequacy:63.55% Controlling Factor: Bending Stress Y Module Location: Window Header - Bedroom Module Level: Roof Module Type: Roof Beam Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 5.5 in. X 5.5 in. X 4 ft Section Adequacy:59.97% Controlling Factor: Bending Stress Y Module Location: Cased Opening Header - Bedroom 2039 N Victoria Drive #24/28/2025 Page 2 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr Module Level: Roof Module Type: Roof Beam Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 3.5 in. X 5.5 in. X 5 ft Section Adequacy:67.12% Controlling Factor: Bending Stress Y Module Location: Ceiling Flush Beam - Kitchen Soffit Module Level: Roof Module Type: Roof Beam Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 3.5 in. X 5.5 in. X 12.33 ft Section Adequacy:51.76% Controlling Factor: Bending Stress Y Module Location: Ridge Beam Post Module Level: Main Floor Module Type: Column Material Type: Solid Sawn Douglas Fir-Larch No. 2 Member Dimensions: (1) 3.5 in. X 5.5 in. X 12.5 ft Section Adequacy:58.02% Controlling Factor: Compressive Stress Module Location: Ridge Beam Footing Module Level: Basement Module Type: Isolated Footing Material Type: Concrete Member Dimensions: 2.5 ft. wide X 24 in. tall X 2.5 ft long Section Adequacy:26.64% Controlling Factor: Soil Bearing Pressure Reinforcement: #4 - Longitudinal: 7 Bars. Transversal: 7 Bars Module Location: Door Header Footing Module Level: Basement Module Type: Isolated Footing Material Type: Concrete Member Dimensions: 2 ft. wide X 24 in. tall X 2 ft long Section Adequacy:27.99% Controlling Factor: Soil Bearing Pressure Reinforcement: #4 - Longitudinal: 6 Bars. Transversal: 6 Bars Module Location: New Continuous Footing Module Level: Basement Module Type: Continuous Footing Material Type: Concrete Member Dimensions: 1.5 ft. wide X 24 in. tall Section Adequacy:66.9% Controlling Factor: Soil Bearing Pressure Reinforcement: Unreinforced (Plain) 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Vaulted Rafter - 2x10 CODE: 2022 California Building Code MEMBER TYPE: ROOF RAFTER NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 1.5 X 9.25 24(in) O.C. DRY Vaulted Rafter - 2x10 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 10 Member Slope: 0/12 Actual Length (ft): 10 Roof Pitch: 0/12 O.C. Spacing(in): 24 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 13.88 98.93 2.6 3.16 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 2458 1366 389 2916 939 1600 868 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.1 1.1 1 1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1.15 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 10 0 10 4.167 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Compressive Stress (psi) Tensile Stress (psi) Bearing Stress (psi) Bending-Compression (Unit) Bending-Tension (Unit) PASS/FAIL PASS (80.3%) PASS (56.2%) PASS (81.2%) PASS (99.1%) PASS (98.4%) PASS (87.6%) PASS (56.2%) PASS (56.2%) MAGNITUDE 61.3 861.5 0.135 (=L/889) 17.0 17.0 116.3 0.44 0.44 STRENGTH 311.0 1966.4 0.722 (=L/166) 1983.7 1093.0 939.4 1.00 1.00 LOCATION (ft) 0 5 5 0 10 0 4.9 5.1 LOAD COMBO 1.2D+1.6Lr+L 1.2D+1.6Lr+L D+Lr 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L TIME EFFECT λ 0.8 0.8 0 0.8 0.8 0.8 0.8 0.8 Page 3 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 223 217 440 B 223 217 440 Reaction Location A BLOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft²) Roof Live 20 20 0 10 RoofLive Y Uniform (lbf/ft²) Roof Dead 19 19 0 10 Dead Y Self Weight (lbf/ft) - 3.16 3.16 0 10 Dead Y Page 4 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Vaulted Rafter - 2x10 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Roof Ridge Beam CODE: 2022 California Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Structural Composite Lumber Weyerhaeuser 2.2E Parallam PSL (1) 5.25 X 18 DRY Roof Ridge Beam DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 33.25 Member Slope: 0/12 Actual Length (ft): 33.25 Area Ix Iy BSW Lams Cfn Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 94.5 2551.5 217.05 29.53 1 9 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 2900 2300 290 2900 625 2200 1118.19 Adjusted Values 6261 4968 626 6264 939 2200 1673 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 Bending Adjustment Factors C V = 0.96C r = 1 Volume factor Is applied on a load combination basis And Is Not reflected in the adjusted values BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 33.25 0 33.25 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (68.0%) PASS (25.8%) PASS (2.2%) PASS (31.8%) MAGNITUDE 160.2 3550.9 2.168 (=L/184) 640.8 STRENGTH 501.1 4788.2 2.217 (=L/180) 939.4 LOCATION (ft) 0 16.625 16.625 0 LOAD COMBO 1.2D+1.6Lr+L 1.2D+1.6Lr+L D+Lr 1.2D+1.6Lr+L TIME EFFECT λ 0.8 0.8 0 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 4198 3159 7357 B 4198 3159 7357 Reaction Location A B Page 5 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Roof Live 190 190 0 33.25 RoofLive Y Uniform (lbf/ft) Roof Dead 223 223 0 33.25 Dead Y Self Weight (lbf/ft) - 29.53 29.53 0 33.25 Dead Y Page 6 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Roof Ridge Beam 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Ceiling Joist CODE: 2022 California Building Code MEMBER TYPE: FLOOR JOIST NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 1.5 X 5.5 16(in) O.C. DRY Ceiling Joist DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 14.75 Member Slope: 0/12 Actual Length (ft): 14.75 O.C. Spacing(in): 16 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 8.25 20.8 1.55 1.88 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 2905 1615 389 3208 939 1600 868 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.3 1.3 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1.15 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 14.75 0 14.75 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (87.8%) PASS (39.7%) PASS (23.5%) PASS (95.2%) MAGNITUDE 28.6 1401.7 0.753 (=L/235) 45.2 STRENGTH 233.3 2323.9 0.983 (=L/180) 939.4 LOCATION (ft) 14.75 7.228 7.375 0 LOAD COMBO 1.4D 1.2D+1.6L+0.5Lr D+L 1.2D+1.6L+0.5Lr TIME EFFECT λ 0.6 0.8 0 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 112 43 155 B 112 40 152 Reaction Location A B Page 7 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft²) Ceiling Live 10 10 4 10.25 Live Y Uniform (lbf/ft²) Ceiling Dead 10 10 0 14.75 Dead Y Self Weight (lbf/ft) - 1.88 1.88 0 14.75 Dead Y Page 8 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Ceiling Joist 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Door Header - Supports Ridge CODE: 2022 California Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Structural Composite Lumber Weyerhaeuser 2.2E Parallam PSL (1) 5.25 X 11.875 DRY Door Header - Supports Ridge DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 14.667 Member Slope: 0/12 Actual Length (ft): 14.67 Area Ix Iy BSW Lams Cfn Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 62.34 732.62 143.2 19.48 1 9 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 2900 2300 290 2900 625 2200 1118.19 Adjusted Values 6261 4968 626 6264 939 2200 1673 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 Bending Adjustment Factors C V = 1 C r = 1 Volume factor Is applied on a load combination basis And Is Not reflected in the adjusted values BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 14.667 0 14.66667 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (69.9%) PASS (19.6%) PASS (38.7%) PASS (57.6%) MAGNITUDE 150.9 4032.8 0.600 (=L/293) 398.1 STRENGTH 501.1 5014.7 0.978 (=L/180) 939.4 LOCATION (ft) 0 7.333 7.333 0 LOAD COMBO 1.2D+1.6Lr+L 1.2D+1.6Lr+L D+Lr 1.2D+1.6Lr+L TIME EFFECT λ 0.8 0.8 0 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 2727 1874 4601 B 2725 1872 4597 Reaction Location A B Page 9 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Roof Live 40 40 0 14.667 RoofLive Y Uniform (lbf/ft) Roof Dead 30 30 0 14.667 Dead Y Uniform (lbf/ft) Wall Dead 36 36 0 14.667 Dead Y Point (lbf) Ridge Roof Live 3159 - 7.33 - RoofLive Y Point (lbf) Ridge Roof Dead 4198 - 7.33 - Dead Y Self Weight (lbf/ft) - 19.48 19.48 0 14.667 Dead Y Page 10 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Door Header - Supports Ridge 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Door Header - Bedroom CODE: 2022 California Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 5.5 X 7.5 DRY Door Header - Bedroom DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 10.25 Member Slope: 0/12 Actual Length (ft): 10.25 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 41.25 193.36 103.98 9.41 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 750 475 170 700 625 1300 470 Adjusted Values 1619 1026 367 1512 939 1300 703 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1 1 1 1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 10.25 0 10.25 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (90.2%) PASS (63.5%) PASS (83.3%) PASS (94.9%) MAGNITUDE 28.8 472.2 0.114 (=L/1079) 48.0 STRENGTH 293.8 1295.4 0.683 (=L/180) 939.4 LOCATION (ft) 10.25 5.125 5.125 0 LOAD COMBO 1.2D+1.6Lr+L 1.2D+1.6Lr+L D+Lr 1.2D+1.6Lr+L TIME EFFECT λ 0.8 0.8 0 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 386 205 591 B 386 205 591 Reaction Location A B Page 11 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Roof Live 40 40 0 10.25 RoofLive Y Uniform (lbf/ft) Roof Dead 30 30 0 10.25 Dead Y Uniform (lbf/ft) Wall Dead 36 36 0 10.25 Dead Y Self Weight (lbf/ft) - 9.41 9.41 0 10.25 Dead Y Page 12 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Door Header - Bedroom 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Window Header - Bedroom CODE: 2022 California Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 5.5 X 5.5 DRY Window Header - Bedroom DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 4 Member Slope: 0/12 Actual Length (ft): 4 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 30.25 76.25 76.25 6.9 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 750 475 170 700 625 1300 470 Adjusted Values 1619 1026 367 1512 939 1300 703 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1 1 1 1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 4 0 4 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (79.8%) PASS (60.0%) PASS (90.3%) PASS (92.3%) MAGNITUDE 59.4 518.5 0.026 (=L/1846) 72.6 STRENGTH 293.8 1295.4 0.267 (=L/180) 939.4 LOCATION (ft) 0 2 2 0 LOAD COMBO 1.2D+1.6Lr+L 1.2D+1.6Lr+L D+Lr 1.2D+1.6Lr+L TIME EFFECT λ 0.8 0.8 0 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 564 326 890 B 564 326 890 Reaction Location A B Page 13 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Roof Live 163 163 0 4 RoofLive Y Uniform (lbf/ft) Roof Dead 275 275 0 4 Dead Y Self Weight (lbf/ft) - 6.9 6.9 0 4 Dead Y Page 14 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Window Header - Bedroom 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Cased Opening Header - Bedroom CODE: 2022 California Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3.5 X 5.5 DRY Cased Opening Header - Bedroom DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 5 Member Slope: 0/12 Actual Length (ft): 5 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 19.25 48.53 19.65 4.39 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 2526 1615 389 3208 939 1600 868 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.3 1.3 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 5 0 5 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (80.4%) PASS (67.1%) PASS (87.8%) PASS (92.1%) MAGNITUDE 60.9 664.5 0.041 (=L/1463) 74.4 STRENGTH 311.0 2020.8 0.333 (=L/180) 939.4 LOCATION (ft) 0 2.5 2.5 0 LOAD COMBO 1.2D+1.6Lr+L 1.2D+1.6Lr+L D+Lr 1.2D+1.6Lr+L TIME EFFECT λ 0.8 0.8 0 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 290 271 561 B 290 271 561 Reaction Location A B Page 15 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Roof Live 108.5 108.5 0 5 RoofLive Y Uniform (lbf/ft) Roof Dead 111.5 111.5 0 5 Dead Y Self Weight (lbf/ft) - 4.39 4.39 0 5 Dead Y Page 16 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Cased Opening Header - Bedroom 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Roof LOADING: LRFD MEMBER NAME: Ceiling Flush Beam - Kitchen Soffit CODE: 2022 California Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3.5 X 5.5 DRY Ceiling Flush Beam - Kitchen Soffit DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 12.333 Member Slope: 0/12 Actual Length (ft): 12.33 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 19.25 48.53 19.65 4.39 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 2526 1615 389 3208 939 1600 868 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.3 1.3 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 12.333 0 12.33333 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (88.4%) PASS (51.8%) PASS (67.1%) PASS (96.5%) MAGNITUDE 27.2 731.1 0.271 (=L/546) 33.2 STRENGTH 233.3 1515.6 0.822 (=L/180) 939.4 LOCATION (ft) 0 6.167 6.167 0 LOAD COMBO 1.4D 1.4D D+L 1.4D TIME EFFECT λ 0.6 0.6 0 0.6 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD TOTALY axis A 249 249 B 249 249 Reaction Location A B Page 17 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Soffit Dead 36 36 0 12.333 Dead Y Self Weight (lbf/ft) - 4.39 4.39 0 12.333 Dead Y Page 18 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Ceiling Flush Beam - Kitchen Soffit 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Main Floor LOADING: LRFD MEMBER NAME: Ridge Beam Post CODE: 2022 California Building Code MEMBER TYPE: COLUMN NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3.5 X 5.5 DRY Ridge Beam Post DIAGRAM COLUMN PROPERTIES Start(ft) 0 End(ft): 12.5 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 19.25 48.53 19.65 4.39 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 2526 1615 389 3208 939 1600 868 K F*ϕ 2.16 2.16 2.16 2.16 1.5 1 1.5 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.3 1.3 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 COLUMN DATA Unbraced Length (ft) Column End Span Length (ft) X Y Offset CP Ke(X Axis) Ke(Y Axis) KeL/d (X Axis) KeL/d (Y Axis) 1 12.5 10 1 0 21.82 3.43 PASS-FAIL Compressive Stress (psi) PASS/FAIL PASS (58.0%) MAGNITUDE 527.7 STRENGTH 1256.9 LOCATION (ft) 0 LOAD COMBO 1.2D+1.6Lr+L TIME EFFECT λ 0.8 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALZ axis A 4253 3159 7412 B 0 0 0 Reaction Location A B Page 19 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Axial (lbf) Ridge Dead -4198 -4198 12.5 12.5 Dead Z Axial (lbf) Ridge Roof Live -3159 -3159 12.5 12.5 RoofLive Z Self Weight (lbf/ft) - 4.39 4.39 0 12.5 Dead Z Page 20 2022 California Building Code LRFDPROJECT: 2039 N Victoria Dr Member Name: Ridge Beam Post 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Basement LOADING: ASD MEMBER NAME: Ridge Beam Footing CODE: 2022 California Building Code MEMBER TYPE: ISOLATED FOOTING ACI: ACI 318-19 MATERIAL: Concrete 2.5 (ft) X 2.5 (ft) X 24 (in) Soil Depth TOF: 0 (ft) Bot. (7) #4 Long, (7) #4 Short MATERIAL PROPERTIES FOOTING Width (ft) Length (ft) Depth (in) Volume (ft³) Footing Weight (lb/ft) 2.5 2.5 24 12.5 1812.5 CONCRETE fc' (psi) Ec (psi) Density (lbf/ft³) Agg. Dia. (in) 2500 0 145 0.75 CALCULATION VARIABLES Bo (in) 0 COLUMN Width (in) Length (in) Material Offset X (in) Offset Y (in) 4 6 Wood 0 0 SOIL Bearing Strength (lbf/ft²) Density (lbf/ft³) Cohesion Friction Angle Depth (ft) Rankine Coefficient (Kp) 2000 110 0 30 0 3 REBAR Bottom Bar Size # fy (psi) Es (psi) 4 40000 2.9E+07 COVER Top Cover (in. Bottom Cover (in. Side Cover (in. 3 3 3 PASS-FAIL Soil Bearing Pressure (lbf/ft²) One-Way Shear X (lbf) One-Way Shear Y (lbf) Two-Way Shear (lbf) Moment X (lbf-ft) Moment Y (lbf-ft) Crushing (lbf) Compression (ft²) PASS/FAIL PASS (26.6%) PASS (98.1%) PASS (98.1%) PASS (99.0%) PASS (97.0%) PASS (96.7%) PASS (84.8%) PASS (100.0%) MAGNITUDE 1467.1 883.1 883.1 2668.1 2554.5 2747.3 10092.0 6.3 STRENGTH 2000.0 46687.5 46687.5 258546.7 83776.0 83776.0 66300.0 6.3 LOAD COMBO D+Lr 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L D CALCULATION TYPE ASD LRFD LRFD LRFD LRFD LRFD LRFD LRFD LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf) Roof Live 3159 - 0 - RoofLive Z Point (lbf) Roof Dead 4198 - 0 - Dead Z Page 21 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 Ridge Beam Footing DIAGRAMS Page 22 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr Member Name: Ridge Beam Footing 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Basement LOADING: ASD MEMBER NAME: Door Header Footing CODE: 2022 California Building Code MEMBER TYPE: ISOLATED FOOTING ACI: ACI 318-19 MATERIAL: Concrete 2 (ft) X 2 (ft) X 24 (in) Soil Depth TOF: 0 (ft) Bot. (6) #4 Long, (6) #4 Short MATERIAL PROPERTIES FOOTING Width (ft) Length (ft) Depth (in) Volume (ft³) Footing Weight (lb/ft) 2 2 24 8 1160 CONCRETE fc' (psi) Ec (psi) Density (lbf/ft³) Agg. Dia. (in) 2500 0 145 0.75 CALCULATION VARIABLES Bo (in) 0 COLUMN Width (in) Length (in) Material Offset X (in) Offset Y (in) 4 6 Wood 0 0 SOIL Bearing Strength (lbf/ft²) Density (lbf/ft³) Cohesion Friction Angle Depth (ft) Rankine Coefficient (Kp) 2000 110 0 30 0 3 REBAR Bottom Bar Size # fy (psi) Es (psi) 4 40000 2.9E+07 COVER Top Cover (in. Bottom Cover (in. Side Cover (in. 3 3 3 PASS-FAIL Soil Bearing Pressure (lbf/ft²) Moment X (lbf-ft) Moment Y (lbf-ft) Crushing (lbf) Compression (ft²) PASS/FAIL PASS (28.0%) PASS (98.3%) PASS (98.2%) PASS (90.5%) PASS (100.0%) MAGNITUDE 1440.3 1200.3 1317.3 6270.8 4.0 STRENGTH 2000.0 71698.8 71698.8 66300.0 4.0 LOAD COMBO D+Lr 1.2D+1.6Lr+L 1.2D+1.6Lr+L 1.2D+1.6Lr+L D CALCULATION TYPE ASD LRFD LRFD LRFD LRFD LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf) Roof Live 1874 - 0 - RoofLive Z Point (lbf) Roof Dead 2727 - 0 - Dead Z Page 23 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 Door Header Footing DIAGRAMS Page 24 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr Member Name: Door Header Footing 2039 N Victoria Drive #24/28/2025 PASS DATE: 11/27/2024 COMPANY: JRS Engineering & Design LLC STRUCALC BUILD: StruCalc Pro DESIGNED BY: Jeffrey Schaefer CUSTOMER: REVIEWED BY: -- PROJ. ADDRESS: -- PROJECT NAME: 2039 N Victoria Dr -- LEVEL: Basement LOADING: ASD MEMBER NAME: New Continuous Footing CODE: 2022 California Building Code MEMBER TYPE: CONTINUOUS FOOTING ACI: ACI 318-19 MATERIAL: Concrete 1.5 (ft) Wide X 24 (in) Deep Soil Depth TOF: 0 (ft) Unreinforced (Plain) Concrete MATERIAL PROPERTIES FOOTING Width (ft) Depth (in) Footing Weight (lb/ft) Stemwall Weight (lb/ft) 1.5 24 435 12.08333 CONCRETE fc' (psi) Ec (psi) Density (lbf/ft³) Agg. Dia. (in) 2500 2850000 145 0.75 STEM WALL Width (in) Height (in) Material Stemwall Offset (in) 6 2 Wood 0 SOIL Bearing Strength (lbf/ft²) Density (lbf/ft³) Cohesion Friction Angle Depth (ft) Rankine Coefficient (Kp) 2000 110 0 30 0 3 REBAR Bottom Bar Size # Bottom Bar Spacing (in.) fy (psi) Es (psi) None 3 40000 2.9E+07 COVER Top Cover (in. Bottom Cover (in. Side Cover (in. 3 3 3 PASS-FAIL Soil Bearing Pressure (lbf/ft²) Moment (lbf-ft) Compression (ft²) PASS/FAIL PASS (66.9%) PASS (99.6%) PASS (100.0%) MAGNITUDE 662.1 93.8 1.5 STRENGTH 2000.0 21600.0 1.5 LOAD COMBO D+Lr 1.2D+1.6Lr+L D CALCULATION TYPE ASD LRFD LRFD LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) Dead 383 383 0 1 Dead Z Uniform (lbf/ft) Roof Live 163 163 0 1 RoofLive Z Page 25 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr 2039 N Victoria Drive #24/28/2025 New Continuous Footing DIAGRAMS Page 26 2022 California Building Code ASDPROJECT: 2039 N Victoria Dr Member Name: New Continuous Footing 2039 N Victoria Drive #24/28/2025 BTHROOM/PANTRY ROOF STRUCTURAL MODEL 2039 N Victoria Drive #24/28/2025 JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM VisualAnalysis 21.00.0003, Full Desi www.iesweb.com Page 1 of 6 Bill of Materials: Members Material Section Count Total Length ft Total Volume in^3 Total Weight K Douglas Fir-Larch (North)-No.2 SS 2x6 4 41.6692 4125.2539 0.0769 Total Member Weight = 0.0769 K Member Loads, Uniform Member Service Case Direction Magnitude Full Length?Start Offset ft End Offset ft Projected?Predefined Load CJ Left D Force Y -0.0133 K/ft Yes 0.0000 9.4170 No N.A. CJ Left L Force Y -0.0133 K/ft No 2.7902 9.4170 No N.A. CJ Right D Force Y -0.0133 K/ft Yes 0.0000 10.5830 No N.A. CJ Right L Force Y -0.0133 K/ft No 0.0000 7.1860 No N.A. RR-Left D Force Y -0.0253 K/ft Yes 0.0000 10.8346 No N.A. RR-Left Lr Force Y -0.0200 K/ft Yes 0.0000 10.8346 No N.A. RR-Left W-Y Force Y 0.0160 K/ft Yes 0.0000 10.8346 No N.A. RR-Right D Force Y -0.0253 K/ft Yes 0.0000 10.8346 No N.A. RR-Right Lr Force Y -0.0200 K/ft Yes 0.0000 10.8346 No N.A. RR-Right W-Y Force Y 0.0160 K/ft Yes 0.0000 10.8346 Yes N.A. Member Unity Checks Member Section Unity Check Status Result Case Code Reference Type Design Group CJ Left SS 2x6 0.3580 Pass 2. 1.2D+1.6L+0.5Lr 3.3-1 Strong Flexure Check Ceiling Joists CJ Right SS 2x6 0.4737 Pass 2. 1.2D+1.6L+0.5Lr 3.3-1 Strong Flexure Check Ceiling Joists RR-Left SS 2x6 0.7023 Pass 3. 1.2D+1.6Lr+L 3.9-3 Combined Check Roof Rafters RR-Right SS 2x6 0.7023 Pass 3. 1.2D+1.6Lr+L 3.9-3 Combined Check Roof Rafters Ceilin Joists: Results Configuration Has Bolt Holes: False Multi-piece Lams: False Axial Manual Kz: False Kz Sidesway?: False Manual Ky: False Ky Sidesway?: False Beam Beam Type: Simply Supported Loading Pattern: Uniform Tension Flange On Bottom?: False Override Lbi?: False End Notch Type: No Notches Bearing length at start: 0 in Bearing length at end: 0 in Check bearing at start?: False Check bearing at end?: False Shear "@ d" from start?: False Shear "@ d" from end?: False 2039 N Victoria Drive #24/28/2025 JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM VisualAnalysis 21.00.0003, Full Desi www.iesweb.com Page 2 of 6 Ceilin Joists: Results (continued) Deflections Strong (dy): Member Span Ratio 'L only': 240 'W or S only': 240 'D + L': 180 Other: 180 Weak (dz): None C-Factors Moisture Condition: Dry Service Condition Temp. Range: T <= 100F Wet Service Factor, CM: Ignore Temperature Factor, Ct: Calculate Incising Factor, Ci: Ignore Repetitive Member Factor, Cr: Calculate Buckling Stiffness Factor, CT: Ignore Bearing Area Factor, Cb: Ignore Slenderness Limit Increase: False Curvature Factor, Cc: 1 Pole/Pile Treatment: Air Dried Pole/Pile Group Count: 1 Overrides Override CF: False Override CI: False Override CL: False Override CP: False Override CV: False Override Ccs: False Override Cct: False Override Cfu: False Override Cls: False Override Cvr: False Material Overrides Override Ft (Poles & Piles): False Override Fcp: False Neglect Size Constraints?: False Wood Material: Douglas Fir-Larch (North)-No.2 Specification: NDS 2018 LRFD Overstrength?: False Live Load Reduction: None Disable Checks?: False Check Level: Each Limit State Bracing Lateral Top (+y): Unbraced Lateral Bottom (-y): Continuous Strong (z): Unbraced Size Constraints Limit Depth?: False Limit Width?: False Ceiling Joists: Strong Deflection Check (extreme rows: max) Member Section Offset ft Result Case Demand dy in Capacity dy in Code Reference Unity Check Details CJ Right SS 2x6 5.2915 D+L -0.2157 0.7055 IBC 1604.3.1 0.3058 CM(E) = 1, Ct = 1, Ci = 1, Cfu = 1, L/Δ = 588.64 Ceiling Joists: Strong Flexure Check (extreme rows: max) Member Section Offset ft Result Case Demand fbz Ksi Capacity Fbz Ksi Code Reference Unity Check Details CJ Right SS 2x6 5.0798 2. 1.2D+1.6L+0.5Lr 0.7832 1.6534 3.3-1 0.4737 Lb = 10.583 ft, Mz = 0.49359 K-ft, E'min = 867.68 Ksi, CM(E) = 1, Ct = 1, Ci = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, ϕ = 0.85, CM(Fb) = 1, CL = 0.7533, CF(Fb) = 1.3, Cr = 1.15, Kf(Bending) = 2.54, Lambda = 0.8 Ceiling Joists: Strong Shear Check (extreme rows: max) Member Section Offset ft Result Case Demand fvy Ksi Capacity Fvy Ksi Code Reference Unity Check Details CJ Right SS 2x6 0.0000 2. 1.2D+1.6L+0.5S 0.0359 0.3110 3.4-1 0.1155 V = 0.19759 K, CM = 1, Ct = 1, Ci = 1, Kf(Shear) = 2.88, ϕ = 0.75, Lambda = 0.8 2039 N Victoria Drive #24/28/2025 JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM VisualAnalysis 21.00.0003, Full Desi www.iesweb.com Page 3 of 6 Ceilin Joists: Combined Check (extreme rows: max Member Section Offset ft Result Case Demand Capacity Code Reference Unity Check Details CJ Right SS 2x6 5.0798 2. 1.2D+1.6L+0.5S 0.4426 1.0000 3.9-2 Strong 0.4426 Fx = 0.4237 K, KLz = 10.583 ft, KLy = 0 ft, Lb = 10.583 ft, Mz = 0.49359 K-ft, My = 0 K-ft, E'min = 867.68 Ksi, Fbz* = 2.1948 Ksi, Fbz** = 1.6534 Ksi, Fby* = 2.5241 Ksi, Fby** = 2.5241 Ksi, CM(E) = 1, Ct = 1, Ci = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, ϕ = 0.85, CM(Fb) = 1, CL = 0.7533, CF(Fb) = 1.3, Cr = 1.15, Kf(Bending) = 2.54, Lambda = 0.8, Kz = 1, Ky = 1 Ceiling Joists: Axial Check (extreme rows: max) Member Section Offset ft Result Case Demand fa Ksi Capacity Fa Ksi Code Reference Unity Check Details CJ Right SS 2x6 0.0000 3. 1.2D+1.6Lr+L 0.1017 1.1232 3.8.1 0.0906 Fx = 0.83941 K, CM(Ft) = 1, Ct = 1, CF(Ft) = 1.3, Ci = 1, Kf(Tension) = 2.7, ϕ = 0.8, Lambda = 0.8 Roof Rafters: Results Configuration Has Bolt Holes: False Multi-piece Lams: False Axial Manual Kz: False Kz Sidesway?: False Manual Ky: False Ky Sidesway?: False Beam Beam Type: Simply Supported Loading Pattern: Uniform Tension Flange On Bottom?: False Override Lbi?: False End Notch Type: No Notches Bearing length at start: 0 in Bearing length at end: 0 in Check bearing at start?: False Check bearing at end?: False Shear "@ d" from start?: False Shear "@ d" from end?: False Deflections Strong (dy): Member Span Ratio 'L only': 240 'W or S only': 240 'D + L': 180 Other: 180 Weak (dz): None C-Factors Moisture Condition: Dry Service Condition Temp. Range: T <= 100F Wet Service Factor, CM: Calculate Temperature Factor, Ct: Calculate Incising Factor, Ci: Ignore Repetitive Member Factor, Cr: Calculate Buckling Stiffness Factor, CT: Ignore Bearing Area Factor, Cb: Ignore Slenderness Limit Increase: False Curvature Factor, Cc: 1 Pole/Pile Treatment: Air Dried Pole/Pile Group Count: 1 Overrides Override CF: False Override CI: False Override CL: False Override CP: False Override CV: False Override Ccs: False Override Cct: False Override Cfu: False Override Cls: False Override Cvr: False Material Overrides Override Ft (Poles & Piles): False Override Fcp: False Neglect Size Constraints?: False 2039 N Victoria Drive #24/28/2025 JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM VisualAnalysis 21.00.0003, Full Desi www.iesweb.com Page 4 of 6 Roof Rafters: Results (continued) Wood Material: Douglas Fir-Larch (North)-No.2 Specification: NDS 2018 LRFD Overstrength?: False Live Load Reduction: None Disable Checks?: False Check Level: Each Limit State Bracing Lateral Top (+y): Continuous Lateral Bottom (-y): Unbraced Strong (z): Unbraced Size Constraints Limit Depth?: False Limit Width?: False Roof Rafters: Stron Deflection Check (extreme rows: max Member Section Offset ft Result Case Demand dy in Capacity dy in Code Reference Unity Check Details RR-Left SS 2x6 5.4173 D+Lr -0.4057 0.7223 IBC 1604.3.1 0.5617 CM(E) = 1, Ct = 1, Ci = 1, Cfu = 1, L/Δ = 320.44 RR-Right SS 2x6 5.4173 D+Lr -0.4057 0.7223 IBC 1604.3.1 0.5617 CM(E) = 1, Ct = 1, Ci = 1, Cfu = 1, L/Δ = 320.44 Roof Rafters: Combined Check (extreme rows: max) Member Section Offset ft Result Case Demand Capacity Code Reference Unity Check Details RR-Left SS 2x6 5.4173 3. 1.2D+1.6Lr+L 0.7023 1.0000 3.9-3 0.7023 Fx = -0.90947 K, KLz = 10.835 ft, KLy = 0 ft, Lb = 0 ft, Mz = 0.87509 K-ft, My = 0 K-ft, FcE1 = 1.2763 Ksi, FcE2 = 7132330 Ksi, FbE = 1041.2 Ksi, E'min = 867.68 Ksi, Fbz' = 2.1946 Ksi, Fby' = 2.5241 Ksi, CM(E) = 1, Ct = 1, Ci = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, ϕ = 0.85, CM(Fb) = 1, CL = 0.99989, CF(Fb) = 1.3, Cr = 1.15, Kf(Bending) = 2.54, Lambda = 0.8, Kz = 1, Ky = 1 RR-Right SS 2x6 5.4173 3. 1.2D+1.6Lr+L 0.7023 1.0000 3.9-3 0.7023 Fx = -0.90947 K, KLz = 10.835 ft, KLy = 0 ft, Lb = 0 ft, Mz = 0.87509 K-ft, My = 0 K-ft, FcE1 = 1.2763 Ksi, FcE2 = 7132330 Ksi, FbE = 1041.2 Ksi, E'min = 867.68 Ksi, Fbz' = 2.1946 Ksi, Fby' = 2.5241 Ksi, CM(E) = 1, Ct = 1, Ci = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, ϕ = 0.85, CM(Fb) = 1, CL = 0.99989, CF(Fb) = 1.3, Cr = 1.15, Kf(Bending) = 2.54, Lambda = 0.8, Kz = 1, Ky = 1 2039 N Victoria Drive #24/28/2025 JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM VisualAnalysis 21.00.0003, Full Desi www.iesweb.com Page 5 of 6 Roof Rafters: Axial Check (extreme rows: max Member Section Offset ft Result Case Demand fa Ksi Capacity Fa Ksi Code Reference Unity Check Details RR-Left SS 2x6 0.0000 3. 1.2D+1.6Lr+L -0.1266 1.1154 3.6.3 0.1135 Fx = -1.0442 K, KLz = 10.835 ft, KLy = 0 ft, Fc* = 2.6611 Ksi, FcE = 1.2763 Ksi, CM(Fc) = 1, Ct = 1, CF(Fc) = 1.1, Ci = 1, Kf(Compression) = 2.4, ϕ = 0.85, CP = 0.41914, CM(E) = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, Lambda = 0.8, Kz = 1, Ky = 1 RR-Right SS 2x6 10.8346 3. 1.2D+1.6Lr+L -0.1266 1.1154 3.6.3 0.1135 Fx = -1.0442 K, KLz = 10.835 ft, KLy = 0 ft, Fc* = 2.6611 Ksi, FcE = 1.2763 Ksi, CM(Fc) = 1, Ct = 1, CF(Fc) = 1.1, Ci = 1, Kf(Compression) = 2.4, ϕ = 0.85, CP = 0.41914, CM(E) = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, Lambda = 0.8, Kz = 1, Ky = 1 Roof Rafters: Strong Flexure Check (extreme rows: max) Member Section Offset ft Result Case Demand fbz Ksi Capacity Fbz Ksi Code Reference Unity Check Details RR-Left SS 2x6 5.4173 3. 1.2D+1.6Lr+L 1.3886 2.1946 3.3-1 0.6327 Lb = 0 ft, Mz = 0.87509 K-ft, E'min = 867.68 Ksi, CM(E) = 1, Ct = 1, Ci = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, ϕ = 0.85, CM(Fb) = 1, CL = 0.99989, CF(Fb) = 1.3, Cr = 1.15, Kf(Bending) = 2.54, Lambda = 0.8 RR-Right SS 2x6 5.4173 3. 1.2D+1.6Lr+L 1.3886 2.1946 3.3-1 0.6327 Lb = 0 ft, Mz = 0.87509 K-ft, E'min = 867.68 Ksi, CM(E) = 1, Ct = 1, Ci = 1, CT = 1, Cfu = 1, Kf(Emin) = 1.76, ϕ = 0.85, CM(Fb) = 1, CL = 0.99989, CF(Fb) = 1.3, Cr = 1.15, Kf(Bending) = 2.54, Lambda = 0.8 Roof Rafters: Strong Shear Check (extreme rows: max) Member Section Offset ft Result Case Demand fvy Ksi Capacity Fvy Ksi Code Reference Unity Check Details RR-Left SS 2x6 10.8346 3. 1.2D+1.6Lr+L -0.0587 0.3110 3.4-1 0.1889 V = -0.32307 K, CM = 1, Ct = 1, Ci = 1, Kf(Shear) = 2.88, ϕ = 0.75, Lambda = 0.8 RR-Right SS 2x6 10.8346 3. 1.2D+1.6Lr+L -0.0587 0.3110 3.4-1 0.1889 V = -0.32307 K, CM = 1, Ct = 1, Ci = 1, Kf(Shear) = 2.88, ϕ = 0.75, Lambda = 0.8 2039 N Victoria Drive #24/28/2025 JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM VisualAnalysis 21.00.0003, Full Desi www.iesweb.com Page 6 of 6 Floor Beam: Results Deflections Strong (dy): Member Span Ratio 'L only': 360 'W or S only': 360 'D + L': 240 Other: 240 Weak (dz): None Axial Manual Kz: False Kz Sidesway?: False Manual Ky: False Ky Sidesway?: False Size Constraints Limit Depth?: False Limit Width?: False Overrides Override Fy?: False Override Cb?: False Override HSS t_des?: False Advanced Torsion: False Steel Material: Empty Specification: AISC 360-16 LRFD Composite Beam?: False Seismic Compactness: Not Ductile Check Constrained Axis FTB?: False Overstrength?: False Live Load Reduction: None Disable Checks?: False Check Level: Each Limit State Bracing Lateral Top (+y): Unbraced Lateral Bottom (-y): Unbraced Strong (z): Unbraced Torsional Bracing Lateral Top (+y): True Lateral Bottom (-y): True Strong (z): True 2039 N Victoria Drive #24/28/2025 Structural Calculations Prepared By: Jeffrey A. Schaefer, P.E. JRS Engineering & Design Project Address: 2039 Victoria Dr Project Description: Detached ADU Lateral Structural Calculations Wind Load Chapter 28 Envelope Procedure Risk Category II Table 1.5-1 Addition Basic Wind Speed (mph) 96 Fig 26.5-1; 26.5-2 Mean Roof Height 9 ft Wind Directionality (Kd) 0.85 Table 26.6-1 Wall Height 13.50 ft Exposure Category C Section 26.7 Max Roof 14 ft Topographic Factor (Kzt) 1.0 Section 26.8 East/West Length 34.0 ft Ground elevation factor (Ke) 1.0 Section 26.9 North/South Length 39.0 ft Enclosure classification Enclosed Section 26.12 Internal Pressure Coefficient (GCp) 0.18 Section 26.13 Velocity pressure coefficient (Kz) 0.7 Table 26.10-1 Velocity pressure (qz) 14.04 Roof Angle 0.00 External Pressure Coefficient Fig C28.3-1 Roof Surface 2 -0.69 Roof Surface 3 -0.37 Windward Wall 0.4 Leeward Wall -0.29 Roof Uplift Wind pressure: Roof (psf) -12.21 Eq 28.3-1 -16194 lbs -7.16 -12 psf -7.72 -277 lbs/purlin end -2.67 1.33 purlin spacing Wind pressure: Wall (psf) 3.09 Eq 28.3-1 700 H2.5A Tie Strength -6.60 1 Floors Addition Overturning (C) Uplift at Wall Base Base Shear (West-East) 3474 lbs 17.68 plf Self Weight Sufficient 0 lbs Base Shear (North-South) 3028 lbs 15.42 plf Self Weight Sufficient 0 lbs Associated Criteria for Buildings and Other Structures Building Profile Total Anchorage 2039 N Victoria Drive #24/28/2025 Seismic Load Risk Category II Table 1.5-1 Seismic Importance Category 1.0 Table 1.5-2 Site Class D Section 11.4.3 Fa 1.18 https://seismicmaps.org/ Ss 1.51 Sds 1.19 Eq 11.4-3 Fv 2.34 S1 0.52 Sd1 0.81 Eq 11.4-4 Seismic Design Category D Table 11.6-2 Response Modification Factor (R) 6.5 Table 12.2-1 Seismic Weight (lbs) - ADU 25,854 Sec 12.7.2 Simplified Lateral Force Procedure Amplication Factor (F) 1.0 Redundancy Factor (ρ) 1.3 Sec 12.3.4.2 Total Base Shear (lbs) - ADU 6,153 Eq 12.14-11 Static Lateral Force Procedure Cs 0.18 Eq 12.8-2 Building Height 12.5 Building Fundamental Period (s) 0.13 Eq 12.8-7 Building Long Period (s) 8 https://seismicmaps.org/ Cs, max 0.94 Eq 12.8-3 and Eq 12.8-4 Cs, min 0.04 Eq 12.8-6 Cs actual 0.18 Redundancy Factor (ρ) 1.3 Sec 12.3.4.2 Total Base Shear (lbs) - ADU 6,153 2039 N Victoria Drive #24/28/2025 2039 N Victoria Drive #24/28/2025 ASCE Hazards Report Address: 2039 N Victoria Dr Santa Ana, California 92706 Standard:ASCE/SEI 7-22 Latitude:33.764006 Risk Category:II Longitude:-117.87085 Soil Class:Default Elevation:137.78450423193863 ft (NAVD 88) Page 1 of 4https://ascehazardtool.org/Wed Nov 27 2024 2039 N Victoria Drive #24/28/2025 PGA M : 0.67 SMS : 1.78 SM1 : 1.22 SDS : 1.19 SD1 : 0.81 T L : 8 SS : 1.51 S1 : 0.52 VS30 : 260 Seismic Design Category:D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 2 of 4https://ascehazardtool.org/Wed Nov 27 2024 2039 N Victoria Drive #24/28/2025