HomeMy WebLinkAboutHISTORIC-825 N Lacy St - PlanVICINITY MAP
SCALE: NTS
AERIAL VIEW
SCALE: NTS
STORY HOUSE
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: V-B
OCCUPANCY:
ROOF TYPE:
SCOPE OF WORK
INSTALLATION OF 8.40 KW GRID TIED PHOTOVOLTAIC SYSTEM
& 13.5 KWH BATTERY
DAVID SMITH
825 N LACY ST, SANTA ANA, CA 92701
BUILDING INFORMATION
SHEET INDEX
AHJ:CITY OF SANTA ANA
PHOTOVOLTAIC SYSTEM SUMMARY ELECTRICAL INFORMATION
1 PHASE/ 3W / 120/240V
UTILITY:
EXISTING
1 LAYER OF COMPOSITION SHINGLE
1
R3/U
GENERAL NOTES
1. THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFIRM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. JOB SAFETY AND
CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER.
2. IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN.
3. THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY
DISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM.
4. THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN
DRAWINGS, IT IS THE CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR TO PERFORMING THE WORK.
5. ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN,COUNTY & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES.
6. DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A
DISCREPANCY IT IS CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY.
7. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE
TO BE BONDED. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A
SUPPLEMENTAL GROUNDING ELECTRODE.
8. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A
CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT.
9. DC CONDUCTORS SHALL BE RUN IN RMC AND SHALL BE LABELED, "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT.
10. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).
11. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE.
12. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.
13. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.
14. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE
PERMANENTLY AND COMPLETELY HELP OFF OF THE ROOF SURFACE. CEC 110.2 - 110.4 / 300.4
15. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT SUFFICE.
16. PV INSTALLATION SHALL COMPLY WITH ARTICLE 690 OF 2022 CEC, CRC REQUIRES THAT SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE RETROFITTED INTO EXISTING DWELLING,
THE REQUIRED SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE LOCATED AS REQUIRED PER SECTION R314 & R315 WITHIN THE CALIFORNIA RESIDENTIAL CODE.
17. NEW ELECTRICAL EQUIPMENT SHALL BE LOCATED AT LEAST THREE (3) FEET FROM GAS METER OR GAS SHUT-OFF VALVES. CPC1208.7.1; CEC 110.26
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
A0
CODE INFORMATION
APN: 39804216
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA RESIDENTIAL CODE (CRC)
2022 CALIFORNIA FIRE CODE (CFC)
2022 CALIFORNIA ELECTRICAL CODE (CEC)
2022 CALIFORNIA MECHANICAL CODE (CMC)
2022 CALIFORNIA PLUMBING CODE (CPC)
2022 CALIFORNIA ENERGY CODE (CENC)
2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN)
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC)
2020 NATIONAL ELECTRICAL CODE (NEC)
AS ADOPTED BY CITY OF SANTA ANA
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST
CURRENT LOS ANGELES COUNTY FIRE CODE. (LACFC)
SCE
(N) 20 REC SOLAR - REC420AA PURE-R (420W) PV MODULES
(N) 1 TESLA POWERWALL 3 - 1707000-XX-Y INVERTER
(N) 8 MCI-1 RSD
(N) 1 TESLA BACKUP SWITCH - 1624171-95-K
RACKING: UNIRAC SOLAR MOUNT
MAIN SERVICE PANEL BUS SIZE: 200A
MAIN SERVICE BREAKER SIZE: 200A
ESS SYSTEM:
Number and Type ESS unit(s): New - 1 X TESLA POWERWALL 3, 240V AC; Existing - 0
ESS unit(s) capacity (kWh/unit): New - 13.5 kWh/TESLA POWERWALL 3, 240V AC. Existing - 0
Inside attached garages: 0 Unit at 0 kWh
Inside detached garages and/or detached accessory structures: 0 Unit at 0 kWh
Outdoors on Exterior Walls: 1 Unit at 13.5 kWh
Outdoors on Ground: 0 Unit at 0 kWh
Other, and/or for another building on the same site, etc: 0 Unit at 0 kWh
DISCONNECTS
Minimum number of disconnects required to turn off all power sources feeding
the home [Utility]: 1
SCOPE OF WORK
ESS system size listed in the Title Block is the total usable energy
Total Energy Capacity capable of being stored in aggregate.
SOLAR A0
SOLAR A1
SOLAR A2
SOLAR A3
SOLAR A4
SOLAR S1
SOLAR E1
SOLAR E2
SOLAR Dn
COVER SHEET
SITE PLAN
PROPERTY PLAN
EQUIPMENT ELEVATION
ESS MOUNTING DETAIL
STRUCTURAL INFORMATION
SINGLE LINE DIAGRAM
CODE REQUIRED SIGNAGE
EQUIPMENT SPEC SHEETS
12/31/25
STAMPED FOR
EXISTING ROOF AND
ATTACHMENT ONLY
The scope of the plans is for the installation
of the solar photovoltaic system only and
the approval is subject to compliance with
all applicable city and state codes and
regulations regarding construction. The
approval of the plans does not constitute
any certification of the accuracy,
completeness, or building permit status of
the existing buildings and structures as
shown.
Bldg#: 101122453
Elec#: 20185119
Approvals:
Elec: M Smith
HISTORIC-825 N
Lacy St2/18/2025
SCALE: 1' = 1/8"
PHOTOVOLTAIC SYSTEM
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
A1
(N) 20 REC SOLAR 420W PV MODULES
MODEL # : REC420AA PURE-R
(N) 8 MCI-1 RSD
(N) 1 TESLA POWERWALL 3
MODEL # : 1707000-XX-Y
1.The ESS Systems shall be separated from doors,
windows, operable openings into buildings, or HVAC
inlets by at least 5 feet.
2.Conduit will run over the roof at 1-1/2" height from the
roof surface.
3.Conduit will be painted to match roof color.
NOTES
This schedule reflects the minimum number of disconnects
required to disconnect all electrical power sources from the
circuitry of the structure.
ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE
Utility Service 1 of 1 200A Main Breaker
Energy Sourcea Disconnection Number
(#X of Y)b
Disconnection
Operation/Equipment/
Devicec
MSP
UMR
ESS
N L
a
c
y
S
t
(N) Solar PV Array 1
10 REC Solar 420W
4 MCI-1 RSD
18 Deg Roof Slope
Orientation: 154 Deg
(N) Solar PV Array 1
10 REC Solar 420W
4 MCI-1 RSD
18 Deg Roof Slope
Orientation: 334 Deg
(N) Tesla Powerwall 3
(E) 200A Main Service Panel
(Disconnect 1 of 1)
(E) Utility Meter
(N) Tesla Backup Switch
(N) System Shutdown
Switch (RSD)
JB
(N) NEMA 3R Junction Box
Gate
Detached Garage
(Non-Habitable)
a
MCI
a
MCI
b
MCI bMCI
MCI
MCI
MCI
MCI
c
c
d
d
EMT Type Conduit
12/31/25
STAMPED FOR
EXISTING ROOF AND
ATTACHMENT ONLY
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
1 Correction 02.10.25
A2SCALE: 1' = 1/16"
N L
a
c
y
S
t
Pu
b
l
i
c
S
i
d
e
w
a
l
k
MSP
UMR
ESS
43'-5"115'-7"
5'-8"
~156
'
~7
1
'
(N) System Shutdown
Switch (RSD)
(E) 200A Main Service Panel
(Disconnect 1 of 1)
(E) Utility Meter
(N) Tesla Backup Switch
(N) Tesla Powerwall 3
Gate
Gate
Gate
Property Line
4'-2"
Detached Garage
(Non-Habitable)
(E) Main House
18'
(E) Shed1
12/31/25
STAMPED FOR
EXISTING ROOF AND
ATTACHMENT ONLY
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
A3
This schedule reflects the minimum number of disconnects
required to disconnect all electrical power sources from the
circuitry of the structure.
ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE
Utility Service 1 of 1 200A Main Breaker
Energy Sourcea Disconnection Number
(#X of Y)b
Disconnection
Operation/Equipment/
Devicec
NOTE: ALL FD Disconnects are within 6 feet from MSP
ELECTRICAL EQUIPMENT ELEVATION
SCALE: 1' = 1/2"
(N) System Shutdown Device
(N) Tesla Powerwall 3
(E) 200A Main Service Panel
(Disconnect 1 of 1)
(N) Tesla Backup Switch
3'
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
A4
BRACKET TO STRUT
MOUNTING LOCATIONS
BRACKET TO STRUT
MOUNTING LOCATIONS
BRACKET TO STRUT
MOUNTING LOCATIONS
BRACKET TO STRUT
MOUNTING LOCATIONS
(1) 12 GAUGE, AND EITHER
1-5/8 INCH OR 7/8 INCH STRUT
POWERWALL 3 BRACKET
1/4" WOOD SCREW WITH WASHER
PER STUD, OF SUFFICIENT
LENGTH FOR AT LEAST 2-½ INCH
EMBEDMENT INTO THE STUDS
1/4" WOOD SCREW WITH WASHER
PER STUD, OF SUFFICIENT
LENGTH FOR AT LEAST 2-½ INCH
EMBEDMENT INTO THE STUDS
19"
SCALE: NTS
FRONT VIEWA
SCALE: NTS
SIDE VIEWB
F.L.F.L.
USE 2 SCREWS TO
MOUNT EACH STRUT TO
STUDS
SCREWS MUST BE
CENTERED ON THE STUD
DRYWALL OR 3/8" MIN.
WOOD SHEATHING REQUIRED
POWERWALL 3 UNIT
(E) 2"x4" OR 2"x6" WOOD
STUDS AT 24" O.C
(1) 12 GAUGE, AND EITHER
1-5/8 INCH OR 7/8 INCH STRUT
24"
43.25"
7.6"
BATTERY MOUNTING DETAIL
HISTORIC-825 N
Lacy St2/18/2025
MODULE TYPE,DIMENSIONS & WEIGHT
ARRAY
ROOF DESCRIPTION
TILT AZIMUTH QTY. ROOF TYPE SPACINGMODULE TYPE = REC SOLAR (420W) MODULES
48"MAX ATTACHMENT DISTANCE:
2" X 8"@24" O.C.
TRUSS SIZE
1 LAYER OF COMPOSITION SHINGLEA1
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
S1
18 DEG 10
MOUNTING PLAN
SCALE: 1' = 1/4"
12"
1 7 8"
2"
8 1 16"
3
3
1 1 4"8"
2 7 8"
8"-16 X 1" SS SERRATED T-BOLT
3
8" HEX FLANGE NUT
UNIRAC FLASHKIT PRO
UNIRAC FLASHKIT PRO
PLYWOOD
SOLAR MODULE
UNIRAC
SUPPORT RAIL
5/16"x3.5" STAINLESS STEEL
LAG BOLT WITH 2 1/2"MIN
THREAD PENETRATION
UNIRAC FLASHKIT
PRO ATTACHMENT
L FOOT
FRAMIN
G
M
E
M
B
E
R
FLASHING
COMPOSITION
SHINGLE
4 1
2''
154 DEG
STRUCTURAL FRAMING DETAIL
SCALE:NTS
EXTERNAL LOAD BEARING WALL CEILING JOIST
EXISTING RAFTERS
2" X 8" @24" O.C.
2" X 8" BLOCKING
48"24"
ATTACHMENT
UNIRAC RAIL
2" X 8"@24" O.C.1 LAYER OF COMPOSITION SHINGLEA218 DEG 10334 DEG
EXISTING RAFTERS
2" X 8" @24" O.C.
12/31/25
STAMPED FOR
EXISTING ROOF AND
ATTACHMENT ONLY
Paymon Eskandanian
Digitally signed
by Paymon
Eskandanian
Date:
2025.02.07
23:33:03+05'30'
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
E1
ELECTRICAL NOTES
1.PROPER LISTING EXPECTED FOR CONDITIONS OF USE
ON ALL LUGS,FITTINGS,CRIMPS,ETC.
2.ALL CONDUIT BEND RADII TO CONFORM THE NEC MINIMUM BEND RADII REQUIREMENTS.
3.MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED
4.EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS.
5.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
6.CONDUIT SIZE BASED ON 2 BENDS MAXIMUM.ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE.
7.AC WIRING SHALL UPSIZE IF VOLTAGE
DROP EXCEEDS 2%.
8.RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH.
CONDUIT WILL RUN OVER THE ROOF AT 1-1/2"
HEIGHT FROM THE ROOF SURFACE
NOTES
ALL THE PHOTOVOLTAIC SYSTEMS WIRES THAT
ON THE ROOF AND SIDE OF THE BUILDING SHALL
BE PROTECTED AGAINST PHYSICAL DAMAGE
PHOTOVOLTAIC SYSTEM IS RAPID
SHUT DOWN READY PER NEC 690.12
BI-DIRECTIONAL
UTILITY METER
SCE
(E) 200A 2P MAIN C/B
CENTER FED
(DISCONNECT 1 OF 1)
INSTALL 60A 2P PV/ESS
C/B AT THE OPPOSITE
END OF BUS FROM
MAIN FEEDER C/B
Connection to the Interior metal water piping
shall be made within 5 feet from the point of
entrance. 250.68(C) (1)
EXISTING GROUNDING SYSTEM
(N) SYSTEM
SHUTDOWN
SWITCH (RSD)
(2) #18 AWG THWN-2
(N) 200A Tesla Backup Switch
120/240V, Model #:1624171-95-K
Mounted Between Meter and Meter Can
EXISTING
200A MAIN SERVICE PANEL
120/240V,1-PHASE, 3-WIRE
(EXTERIOR WALL)
CTRL
MP
P
T
1
(N)TESLA POWERWALL 3
11.5 KW / 13.5kWH
INVERTER/BATTERY
60A/2P, 240V
MODEL #:1707000-xx-y
(EXTERIOR WALL)
MP
P
T
2
MP
P
T
3
MP
P
T
4
MP
P
T
5
MP
P
T
6
(3) #6 AWG THWN-2
(1) #8 AWG CU EGC
3/4" EMT CONDUIT
1.25 X 48A = 60A (60A PV/BATTERY C/B)
J-BOX
NEMA 3R
[DC.2]
[DC.1]
-+-+
STRING (a) MODULES:5 RSD:2
STRING (b) MODULES:5 RSD:2
-+-+
#6 AWG BARE CU
PV ARRAY INFORMATION
20 REC SOLAR 420W SOLAR MODULES
8 MCI-1 RAPID SHUTDOWN DEVICE
1 TESLA POWERWALL 3 INVERTER/BATTERY
MODULE MODEL # REC420AA PURE-R
INVERTER MODEL # 1707000-XX-Y
NUMBER OF STRINGS :
MAX AC OUTPUT CURRENT:
CEC WEIGHTED EFFICIENCY: % @240V
GROUNDING SPECS: IRONRIDGE HAS A UL2703 LISTED
INTEGRATED GROUNDING.NO ADDITIONAL GROUND LUGS AND
COPPER WIRE ARE NEEDED.ROW TO ROW CONNECTION SHALL
BE MADE WITH UL LISTED GROUNDING LUGS.
97.5
48
4
# OF MODULES IN B-CIRCUIT a,b,c,d:5
THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN
ADDITIONAL FASTENER PER SECTION 408.36(D). THE BREAKER AND
FASTENER SHALL BE MADE BY THE SAME MANUFACTURER
[ DC.1] FROM PV MODULES TO J-BOX
( ) #10 AWG PV WIRE, 600V, BLACK2
I-SC = ADC
I-MP = ADC
5 8.88
8.405
59.4
50.0
1.14
[ AC.1] INVERTER TO POI
EXPECTED WIRE TEMP (°C): 39°
TEMP CORRECTION PER NEC TABLE 310.16: 0.91
CIRCUIT CONDUCTOR SIZE:
CIRCUIT CONDUCTOR AMPACITY:
# OF CURRENT CARRYING CONDUCTORS: 3
CONDUIT FILL PER NEC 310.15(B)(3)(a): 1
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B):
1.25 X OUTPUT CURRENT OF INVERTER
1.25 X 48A = 60.0A
DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16:
TEMP CORR. PER NEC 310.16 X
CONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) X
(3) # AWG THWN-2 + (1) #8 AWG CU EGC,3/4" EMT CONDUIT
CIRCUIT CONDUCTOR AMPACITY =0.91 X 1 X 75 = 68.25A
75 A
#6 AWG
6
[ DC.2] FROM J-BOX TO INVERTER
( ) #10 AWG THWN-2, 600V, BLACK & RED
(1) #8 AWG THWN-2 CU EGC, 3/4" EMT CONDUIT
8
V-OC = 338.58 VDC
V-MP = 250.00 VDC
I-SC = 2 * 8.88 = 17.76 ADC
I-MP = 2 * 8.40 = 16.80 ADC
[AC.1]
PCS A
PCS B
PANEL LIMIT FEATURE FOR THE POWERWALL UNIT(S) TO BE UTILIZED
FIELD LABEL TO BE AT POINT OF INTERCONNECTION.
"PCS CONTROLLED CURRENT SETTING: 160A"
THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM
TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. REFER TO THE
MANUFACTURER'S INSTRUCTION FOR MORE INFORMATION." (NEC 2020, 705.13)
THE SUM OF PCS A AND PCS B NOT TO EXCEED 200A
V-OC = * * = 338.58 VDC
V-MP = * = 250 VDC
-+-+
-+-+
STRING (c) MODULES:5 RSD:2
STRING (d) MODULES:5 RSD:2
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
E2
1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT.
2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3/8" LETTER HEIGHT,WHITE ON RED BACKGROUND.
3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO
MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED.
4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,
RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING
THEM.MARKING SHALL BE PLACED EVERY 10',AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS,
AND AT ALL DC COMBINER AND JUNCTION BOXES.
5.DO NOT US SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE.
SIGNAGE NOTES
JUNCTION BOX
PV LOAD CENTER
CODE: PER NEC 110.27(C)
& OSHA 1910.145(F)(7)
CODE: PER NEC 706.15(C)(4)
NEC 690.13(B)
MAIN SERVICE PANEL
AC DISCONNECT
CODE: PER NEC 690.56(C)(2)
MAIN SERVICE PANEL
CODE: PER NEC 605.11.3.1(1)
& NEC 690.56(C)
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF"POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
WARNING
RAPID SHUTDOWN FOR
SOLAR PV SYSTEM
SOLAR ELECTRIC
PV PANELS
CODE: PER NEC 705.12 (B)(3)(2)
MAIN SERVICE PANEL
NEXT TO PV BREAKER
WARNING
POWER SOURCE OUTPUT
CONNECTION. DO NOT
RELOCATE THIS
OVERCURRENT DEVICE.
CONDUIT RACEWAYS
PHOTOVOLTAIC POWER SOURCE
CODE: PER NEC 690.31(D)(2)
AC DISCONNECT
CODE: PER NEC 690.54
AC DISCONNECT
CODE: PER NEC 690.13(B)
240V
48A
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT
NOMINAL OPERATING AC VOLTAGE
MAIN SERVICE PANEL
MAIN SERVICE PANEL
CODE: PER NEC 690.15(B) &
NEC 690.33(D)(2)
DO NOT DISCONNECT
UNDER LOAD
JUNCTION BOX
PV LOAD CENTER
CODE: PER NEC 110.27(C)
& OSHA 1910.145(F)(7)
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
WARNING
AC DISCONNECT
MAIN SERVICE PANEL
CODE: PER NEC 706.15(C)(4)
NEC 690.13(B)
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
WARNING
CONDUIT, CABLES,
PULL BOXES,J-BOX
RACEWAY IS ENERGIZED WHEN
IN THE OPEN POSITION. DO NOT
RELOCATE OR CUT
WARNING
PHOTOVOLTAIC
AC DISCONNECT
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
CODE: PER NEC 690.13(B)
MAIN SERVICE DISCONNECT
UTILITY METER
WARNING
TRI POWER SUPPLY
SOURCES: UTILITY GRID, BATTERY AND
PV SOLAR ELECTRIC SYSTEM
#1
Panel-Interior Placards are required to be placed inside a panel to
identify specific switches/ breakers when multiple switches within a
single panel/enclosure are required to be operated.
FIGURE 2 – PANEL-INTERIOR PLACARD
#2
MAIN SERVICE PANEL
6. PLACARD SIZE AND MATERIAL:
a. PANEL-EXTERIOR PLACARDS (FIGURE 1) SHALL BE A MINIMUM 2 INCHES TALL BY 3.5
INCHES WIDE WEATHER RESISTANT PLASTIC, WITH VERBIAGE ENGRAVED.
b. PANEL-INTERIOR PLACARDS (FIGURE 2) SHALL BE A MINIMUM 7/16 INCHES
TALL BY 3⁄4 INCHES WIDE WEATHER RESISTANT PLASTIC, WITH VERBIAGE ENGRAVED.
F.D. - ELECTRICAL
BLDG DISCONNECT
# 2 OF 2
FIGURE 1 – EXTERIOR PLACARD
F.D. - ELECTRICAL
BLDG DISCONNECT
# 1 OF 2
ENERGY
STORAGE
SYSTEM
DISCONNECT
CODE: PER NEC 706.15(C)
ESS
CAUTION:
MULTIPLE SOURCES OF POWER
WITH DISCONNECTS LOCATED AS SHOWN
PCS CONTROLLED CURRENT
SETTING:160A
The maximum output current from this
system towards the main panel is
controlled electronically.Refer to the
manufacturer's instructions for more
information
WARNING: THIS SENSOR IS PART OF POWER CONTROL
SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH THE
SAME TYPA AND RATING
SIGNAGE LOCATIONS:
• CT's
Sticker
Sticker
MSP
UM
R
ESS
N
L
a
c
y
S
t
GATE
POWERWALL 3
SERVICE POINT &
UTILITY METERING
(DISCONNECT 1 OF 1)
RSDPHOTOVOLTAIC
ARRAY ON ROOF
PHOTOVOLTAIC
ARRAY ON ROOF
YOU ARE HERE
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D1
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D2
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D3
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D4
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D5
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D6
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D7
HISTORIC-825 N
Lacy St2/18/2025
Installation of
8.40 KW Grid Tied
Photovoltaic System
& 13.5 kWh Battery
Solar Individual
Permit Package
DATE DRAWN
DRAWN BY
SCALE
NAREK Y.
AS INDICATED
SHEET
Rev Description Date
01.07.25
CONTRACTOR
California Solar &
Electric, Inc.
Address:
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
Phone Number:
Tel:(628)998-4928
CSLB License #1073677
Class C-10
Contractor Signature
SYSTEM SIZE (DC):
STC: 20 X 420 = 8.40kW DC
PTC: 20 X 402.5 = 8.05kW DC
SYSTEM SIZE (AC):
11.5kW AC
DAVID SMITH
825 N Lacy St, Santa
Ana, CA 92701
D8
HISTORIC-825 N
Lacy St2/18/2025
Project:
Location:
STRUCTURAL CERTIFICATION LETTER
To:
Project:
To Whom It May Concern
DESIGN CRITERIA:
DESCRIPTION OF EXISTING ROOF STRUCTURE:
ROOF 1: 2x8 Rafters @ 24" o.c. with a maximum unsupported horizontal span of 14'-0" and a slope of 18 degrees
Max PV mount spacing- Landscape config: 48", Portrait config: 48", Pattern: Staggered (ROOF 1)
Attachment to Framing: (1) 5/16" Lag Screw(s) w/ 2.5" min embed @ above spacing (ROOF 1)
Paymon Eskandanian, SE, PE
Laguna Consulting Engineers
Roof Dead Load(s): 8 psf, Comp Shingles (ROOF 1)
CONCLUSIONS:
Please contact me should you have any questions or comments regarding this project.
825 North Lacy Street
Santa Ana, CA 92701
David Smith
Santa Ana, CA
30011 Ivy Glenn Dr, Ste 219, Laguna Niguel, CA 92677
info@lagunaengineers.com
January 9, 2025
CS&E
26074 Avenue Hall Ste 13
Santa Clarita, CA 91355
David Smith - Solar Project
New PV System Dead Load(s): 2.63 psf
Applicable Codes: 2022 California Building Code, ASCE 7-16
Risk/ Occupancy Category: II
Roof Live Load(s): 20 psf, 0 psf Under PV
Ground Snow Load: 0 psf
Basic Wind Speed: 110 mph, Exposure Category: C
A jobsite observation of the condition of the existing framing system was performed by an audit team of CS&E as a request from Laguna
Consulting Engineers. All review is based on these observations and the design criteria listed below and only deemed valid if the provided
information is true and accurate.
The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing, and supporting structure with the
additional loading due to the installation of the solar PV panels. The design of racking (rail spans, mounting hardware, etc.), PV panels and all
other structure is by others and shall be per the specified design criteria. Laguna Consulting Engineers assumes no responsibility for improper
installation of PV panels, racking, or waterproofing. Prior to starting construction, contractor shall verify the framing sizes, spacings, and spans
noted in the stamped plans and this letter and notify the Engineer of Record of any discrepancies noted. This review relies on the roof’s
structural system having been originally designed and constructed in accordance with the building code requirements and having been
maintained to be in good condition.
ROOF 1: Adequate to support the imposed loading - No structural upgrades required
Page 1
12/31/25
HISTORIC-825 N
Lacy St2/18/2025
Project:
Location:
GRAVITY LOADS (ROOF 1)
2.63 psf
Note: PV System Weight Provided by Client/ Manuf.
ASCE Ch-3
4 psf
2 psf
1.52 psf
0 psf
0.49 psf
8 psf
ASCE Ch-4
20 psf
≤ 200 sq.ft
1
4/12 (18 Deg.)
1.00
20 psf
Note: Live Load Under PV Arrays = 0 PSF.
ASCE Ch-7
0 psf
1 Table 7.3-1
1 Table 7.3-1
1
N/A psf
0.0 psf Eqn 7.3-1
4/12 (18 Deg.)
1.00
N/A psf Sec 7.3.4
N/A psf
0.0 psf Eqn 7.4-1
3. ROOF LIVE LOAD
ITEM
Roof Live Load, L0 =
Tributary Area Supported By Member, AT =
Tributary Area Reduction Factor, R1 =
Roof Slope =
4. ROOF SNOW LOAD
ROOF SNOW LOAD, ps = Cs . pf =
AHJ Minimum Flat Roof Snow Load, pf_min_AHJ =
Flat Roof Snow Load,
pf = 0.7CeCtIspg + pf_sur ; pf ≥ pf_min_AHJ –› pf =
Roof Slope =
Surface Type =All Other Surfaces
Slope Factor, Cs =
Exposure Factor (Fully Exposed), Ce =
Thermal Factor (Cold Roof), Ct =
Snow Importance Factor, Is =
David Smith
Santa Ana, CA
30011 Ivy Glenn Dr, Ste 219, Laguna Niguel, CA 92677
info@lagunaengineers.com
1. NEW PV SYSTEM
DEAD LOAD
ITEM LOAD
(N) PV SYSTEM DEAD LOAD, DLPV-N =
2. ROOF DEAD LOAD
ITEM LOAD
Comp Shingles
Plywood Deck
2x8 Rafters @ 24" O.C.
Vaulted Ceiling
Miscellaneous
ITEM VALUE
Ground Snow Load, pg =
VALUE
Slope Reduction Factor, R2 =
ROOF LIVE LOAD, LLROOF = L0 . R1 . R2 =
ROOF DEAD LOAD, DLROOF =
AHJ Minimum Roof Snow Load, pS_minAHJ =
Minimum Low-Slope Roof Snow Load, pLS_min =
Page 2
HISTORIC-825 N
Lacy St2/18/2025
Project:
Location:
WIND LOADS (ROOF 1)
Wind loads on standoffs and their attachment to the underlying structure are determined as per the requirements for
rooftop solar panels parallel to the roof surface (ASCE 7-16, Section 29.4.4).
Risk Category =II
Basic Wind Speed, V (ULT) =110 mph
Wind Directionality Factor, Kd =0.85 Table 26.6-1
Exposure Category =C
Topographic Factor, Kzt =1.0 Table 26.8-1
Ground Elevation Factor, Ke =1.0 Table 26.9-1
Mean Roof Height, h =25 ft (Max)
Velocity Pressure Exposure Coefficient, Kz =0.95 Table 26.10-1
Velocity Pressure, qh = 0.00256KzKztKdKeV2 =24.91 psf (ULT)Eq. 26.10-1
qₕ_ASD = 0.6 x qₕ_ULT =14.94 psf
Roof Type =Gabled
Roof Slope =18 Degrees
Array Edge Factor, ɣE =1.0 29.4.4
Effective Wind Area, Aeff =See Table Below 26.2
Design Wind Pressures (ASD), pUPLIFT (ASD)=qh (ASD) . (GCp). ɣE . ɣa ; pASD_MIN = 10 psf Eq. 29.4-7
Standoff Net Uplift Forces, PUplift (ASD) (lbs) =pWIND ASD x Atrib - 0.6PDL (See Table Below)
DOWNWARD
ALL
ZONE 1
(Interior)
ZONE 2
(Edge)
ZONE 3
(Corner)
ZONE 1
(Interior)
ZONE 2
(Edge)
ZONE 3
(Corner)ALL ZONES
48.00 48.00 32.00 48.00 48.00 32.00 48.00
3.06 3.06 3.06 1.70 1.70 1.70 3.06
12.23 12.23 8.16 6.82 6.82 4.54 12.23
Pressure Equalization Factor, ɣA 0.76 0.76 0.80 0.80 0.80 0.80 0.80
-2.00 -2.87 -3.60 -2.00 -3.00 -3.60 0.57
-22.9 -32.9 -43.0 -23.9 -35.9 -43.0 10.0
-260 -383 -338 -152 -234 -188 155
ROOF ATTACHMENT CHECKS
Max Standoff Uplift (ASD) ==383 lbs
Mount Allowable Uplift ==450 lbs (Per Manuf.)
Standoff Demand/Capacity Ratio, DCR ==85%< 100%, Therefore O.K.
Fastener Size and Type ==5/16”
No. of Fasteners per Standoff, N ==1
Min Fastener Embed Into Framing, T ==2.5 in
Fastener Allowable Pullout, W ==246 lb/in
Wind Load Duration Factor, LDF =1.6
Additional Factor of Safety, F.S ==1.5
=656 lbs
Fastener Demand/Capacity Ratio, DCR ==58%< 100%, Therefore O.K.
Lag Screw(s)
LANDSCAPE
UPLIFT
Standoff Net Uplift Forces,
PUplift (ASD) (lbs)
Effective/Trib. Area, ATrib (ft2)
PORTRAIT
ZONE
GCp
Design Wind Pressures (ASD),
pUPLIFT (ASD) (psf)
Standoff X-Spacing (in)
Trib. Width (ft)
PRESSURES
Fastener Group Allowable Pullout Capacity
David Smith
Santa Ana, CA
30011 Ivy Glenn Dr, Ste 219, Laguna Niguel, CA 92677
info@lagunaengineers.com
Panel Configuration
Page 3
HISTORIC-825 N
Lacy St2/18/2025
Project:
Location:
MEMBER CHECKS (ROOF 1)PASS
1. (E) WOOD ROOF CONSTRUCTION:
ROOF SLOPE =18°
FRAMING TYPE =Rafters
WOOD SPECIES & GRADE =DF #2
RAFTER OR TRUSS TOP CHORD SIZE =2x8 (S =13.14 in^3 ; I = 47.63 in^4)
RAFTER OR TRUSS SPACING =24" o.c.
MEMBER HORIZONTAL SPAN, L =14'-0"14
2. MEMBER LOADING:
GOVERNING LOAD CASE =
TOTAL LOAD, WTL =
3. BENDING CHECKS:
REFERENCE DESIGN BENDING STRESS, Fb =900 psi
LOAD DURATION FACTOR, Cd =0.90
SIZE FACTOR, CF =1.20
REPETITIVE MEMBER FACTOR, Cr =1.15
ALLOWABLE BENDING STRESS, F'b = Fb x Cd x Cf x Cr =1,118 psi
MEMBER BENDING STRESS, fb = Mmax / S =500 psi
BENDING DEMAND-CAPACITY RATIO = fb / F'b =45%< 100%BENDING O.K.
4. SHEAR CHECKS:
REFERENCE DESIGN SHEAR STRESS, Fv =180 psi
LOAD DURATION FACTOR, Cd =0.90
ALLOWABLE SHEAR STRESS, F'v = Fv x Cd =162 psi
MAX SHEAR, Vmax = WTL.L / 2 =156 lbs
MEMBER AREA, A =10.88 in2
MEMBER SHEAR STRESS, fv = Vmax / A =14.4 psi
SHEAR DEMAND-CAPACITY RATIO = fv / F'v =9%< 100%SHEAR O.K.
5. DEFLECTION CHECKS:
ALLOWABLE DEFLECTION (TOTAL LOAD), ΔALL-TL =(L/180)E =
=0.933 in SPAN TYPE =
MAX DEFLECTION (TOTAL LOAD), ΔMAX-TL =5WL^4/384EI
=0.254 in (L/663)
ΔMAX-TL <ΔALL-LL TOTAL LOAD DEFLECTION O.K.
* RLL = 0 PSF UNDER PV
16,00,000 psi
Simple Span
DL + PV
22 plf
ROOF SNOW LOAD 0.0 0.0 0.0
ROOF DEAD LOAD
ROOF LIVE LOAD*0.0 0.0 0.0
8.0 8.4 16.8
PV DEAD LOAD 2.6 2.8 5.5
30011 Ivy Glenn Dr, Ste 219, Laguna Niguel, CA 92677
info@lagunaengineers.com
LOAD TYPE UNIFORM LOAD
(PSF)
U.L. PROJECTION
OVER HORIZ. SPAN (PSF)
MEMBER DESIGN
LOAD (PLF)
David Smith
Santa Ana, CA
Page 4
HISTORIC-825 N
Lacy St2/18/2025
Project:
Location:
LATERAL (SEISMIC) LOAD CHECKS DUE TO ADDITION OF (N) PHOTOVOLTAIC SYSTEM
PER 2021 IEBC | 2022 CEBC SECTION 503.4
Existing Roof Seismic Weight:
Existing Seismic Weight @ Roof Level, WE =
New PV System Seismic Weight:
Seismic Weight of New PV System, WPV =
9.6%< 10%, Therefore O.K.
David Smith
Santa Ana, CA
10,324 LBS
WEIGHT
(LBS)
968
2,324
2,344
4,688
* Note: Wall Height, H= 8'-0"
Therefore, the exception provided under IEBC / CEBC Section 503.4 applies since the (N) load due
to the addition of PV System does not exceed the 10% threshold of the existing seismic weight.
% Increase in Lateral (Seismic) Weight @ Roof Level
Due to PV System Addition, %-Increase = WPV / WE =
987 LBS
ELEMENT
UNIT WEIGHT
(PSF)
AREA
(SQ.FT)
WEIGHT
(LBS)
PV System 2.63 375.3 987
AREA
(SQ.FT)
UNIT WEIGHT
(PSF)
1945
5868
Interior Walls*
Exterior Walls*
5864Ceiling
194
Roof DL
(7/8" Stucco)
12
30011 Ivy Glenn Dr, Ste 219, Laguna Niguel, CA 92677
info@lagunaengineers.com
ELEMENT
Page 5
HISTORIC-825 N
Lacy St2/18/2025
26074 Avenue Hall, Suite 13, Valencia, CA 91355
(626) 998-4928
chris@californiasolarandelectric.com
02/03/2025
City of Santa Ana
**Subject: Permission to Install Solar Equipment at the Residence of David
Smith**
Dear City of Santa Ana,
This letter serves as confirmation that Mr. David Smith, homeowner at 825 N
Lacy St, Santa Ana, CA 92701, has granted California Solar & Electric
permission to install solar equipment at his property.
We are authorized to perform all necessary work related to the solar
installation, including but not limited to:
* Installation of solar panels
* Installation of inverters and other electrical components
* Wiring and connection to the electrical grid
Mr. Smith's signature below confirms his consent for this work to be
conducted by California Solar & Electric.
We have included a copy of Mr. Smith's signed agreement with our company for
your records. We are committed to adhering to all city ordinances and
regulations regarding solar installations. Please do not hesitate to contact
us if you require any further information or documentation.
Sincerely,
Christopher Massoth
Owner / CEO
**Homeowner Consent:**
Docusign Envelope ID: 9F9854F9-4B17-42BE-AF1F-60C2BE50D83F
2/3/2025
HISTORIC-825 N
Lacy St2/18/2025
I, David Smith, homeowner at 825 N Lacy St, Santa Ana, CA 92701, hereby grant
permission to California Solar & Electric to install solar equipment at my
property as described in this letter.
____________________________
Signature of David Smith
____________________________
Printed Name of David Smith
____________________________
Date
Docusign Envelope ID: 9F9854F9-4B17-42BE-AF1F-60C2BE50D83F
David Smith
2/3/2025
HISTORIC-825 N
Lacy St2/18/2025
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
Chris Massoth Christopher Massoth
02/7/25626-998-4928
kalen@californiasolarandelectric.com
825 N Lacy St
1073677
CALIFORNIA SOLAR & ELECTRIC
HISTORIC-825 N
Lacy St2/18/2025
Certificate Of Completion
Envelope Id: 9F9854F9-4B17-42BE-AF1F-60C2BE50D83F Status: Completed
Subject: Complete with Docusign: Permission To Install.docx
Source Envelope:
Document Pages: 2 Signatures: 2 Envelope Originator:
Certificate Pages: 5 Initials: 0 California Solar & Electric, Inc
AutoNav: Enabled
EnvelopeId Stamping: Enabled
Time Zone: (UTC-08:00) Pacific Time (US & Canada)
26074 Avenue Hall
Ste 13
Valencia, CA 91355
chris@californiasolarandelectric.com
IP Address: 76.90.138.219
Record Tracking
Status: Original
2/3/2025 11:35:49 AM
Holder: California Solar & Electric, Inc
chris@californiasolarandelectric.com
Location: DocuSign
Signer Events Signature Timestamp
California Solar & Electric
chris@californiasolarandelectric.com
CEO
California Solar & Electric
Security Level: Email, Account Authentication
(None)
Signature Adoption: Pre-selected Style
Using IP Address: 76.90.138.219
Sent: 2/3/2025 11:40:14 AM
Viewed: 2/3/2025 11:56:43 AM
Signed: 2/3/2025 11:57:52 AM
Electronic Record and Signature Disclosure:
Not Offered via Docusign
David Smith
David@dbs-a.com
Security Level: Email, Account Authentication
(None)
Signature Adoption: Pre-selected Style
Using IP Address: 76.170.2.192
Sent: 2/3/2025 11:40:13 AM
Viewed: 2/3/2025 8:49:34 PM
Signed: 2/3/2025 8:49:50 PM
Electronic Record and Signature Disclosure:
Accepted: 2/3/2025 8:49:33 PM
ID: 156416f3-da51-4182-8a40-c3b6366eb5a4
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 2/3/2025 11:40:14 AM
Certified Delivered Security Checked 2/3/2025 8:49:34 PM
HISTORIC-825 N
Lacy St2/18/2025
Envelope Summary Events Status Timestamps
Signing Complete Security Checked 2/3/2025 8:49:50 PM
Completed Security Checked 2/3/2025 8:49:50 PM
Payment Events Status Timestamps
Electronic Record and Signature Disclosure
HISTORIC-825 N
Lacy St2/18/2025
ELECTRONIC RECORD AND SIGNATURE DISCLOSURE
From time to time, California Solar & Electric, Inc (we, us or Company) may be required by law
to provide to you certain written notices or disclosures. Described below are the terms and
conditions for providing to you such notices and disclosures electronically through the DocuSign
system. Please read the information below carefully and thoroughly, and if you can access this
information electronically to your satisfaction and agree to this Electronic Record and Signature
Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to
use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign
system.
Getting paper copies
At any time, you may request from us a paper copy of any record provided or made available
electronically to you by us. You will have the ability to download and print documents we send
to you through the DocuSign system during and immediately after the signing session and, if you
elect to create a DocuSign account, you may access the documents for a limited period of time
(usually 30 days) after such documents are first sent to you. After such time, if you wish for us to
send you paper copies of any such documents from our office to you, you will be charged a
$0.00 per-page fee. You may request delivery of such paper copies from us by following the
procedure described below.
Withdrawing your consent
If you decide to receive notices and disclosures from us electronically, you may at any time
change your mind and tell us that thereafter you want to receive required notices and disclosures
only in paper format. How you must inform us of your decision to receive future notices and
disclosure in paper format and withdraw your consent to receive notices and disclosures
electronically is described below.
Consequences of changing your mind
If you elect to receive required notices and disclosures only in paper format, it will slow the
speed at which we can complete certain steps in transactions with you and delivering services to
you because we will need first to send the required notices or disclosures to you in paper format,
and then wait until we receive back from you your acknowledgment of your receipt of such
paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to
receive required notices and consents electronically from us or to sign electronically documents
from us.
All notices and disclosures will be sent to you electronically
Electronic Record and Signature Disclosure created on: 6/24/2021 8:09:14 PM
Parties agreed to: David Smith HISTORIC-825 N
Lacy St2/18/2025
Unless you tell us otherwise in accordance with the procedures described herein, we will provide
electronically to you through the DocuSign system all required notices, disclosures,
authorizations, acknowledgements, and other documents that are required to be provided or made
available to you during the course of our relationship with you. To reduce the chance of you
inadvertently not receiving any notice or disclosure, we prefer to provide all of the required
notices and disclosures to you by the same method and to the same address that you have given
us. Thus, you can receive all the disclosures and notices electronically or in paper format through
the paper mail delivery system. If you do not agree with this process, please let us know as
described below. Please also see the paragraph immediately above that describes the
consequences of your electing not to receive delivery of the notices and disclosures
electronically from us.
How to contact California Solar & Electric, Inc :
You may contact us to let us know of your changes as to how we may contact you electronically,
to request paper copies of certain information from us, and to withdraw your prior consent to
receive notices and disclosures electronically as follows:
To contact us by email send messages to: chris@californiasolarandelectric.com
To advise California Solar & Electric, Inc of your new email address
To let us know of a change in your email address where we should send notices and disclosures
electronically to you, you must send an email message to us
at chris@californiasolarandelectric.com and in the body of such request you must state: your
previous email address, your new email address. We do not require any other information from
you to change your email address.
If you created a DocuSign account, you may update it with your new email address through your
account preferences.
To request paper copies from California Solar & Electric, Inc
To request delivery from us of paper copies of the notices and disclosures previously provided
by us to you electronically, you must send us an email
to chris@californiasolarandelectric.com and in the body of such request you must state your
email address, full name, mailing address, and telephone number. We will bill you for any fees at
that time, if any.
To withdraw your consent with California Solar & Electric, Inc
To inform us that you no longer wish to receive future notices and disclosures in electronic
format you may:
HISTORIC-825 N
Lacy St2/18/2025
i. decline to sign a document from within your signing session, and on the subsequent page,
select the check-box indicating you wish to withdraw your consent, or you may;
ii. send us an email to chris@californiasolarandelectric.com and in the body of such request you
must state your email, full name, mailing address, and telephone number. We do not need any
other information from you to withdraw consent.. The consequences of your withdrawing
consent for online documents will be that transactions may take a longer time to process..
Required hardware and software
The minimum system requirements for using the DocuSign system may change over time. The
current system requirements are found here: https://support.docusign.com/guides/signer-guide-
signing-system-requirements.
Acknowledging your access and consent to receive and sign documents electronically
To confirm to us that you can access this information electronically, which will be similar to
other electronic notices and disclosures that we will provide to you, please confirm that you have
read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for
your future reference and access; or (ii) that you are able to email this ERSD to an email address
where you will be able to print on paper or save it for your future reference and access. Further,
if you consent to receiving notices and disclosures exclusively in electronic format as described
herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before
clicking ‘CONTINUE’ within the DocuSign system.
By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm
that:
You can access and read this Electronic Record and Signature Disclosure; and
You can print on paper this Electronic Record and Signature Disclosure, or save or send
this Electronic Record and Disclosure to a location where you can print it, for future
reference and access; and
Until or unless you notify California Solar & Electric, Inc as described above, you
consent to receive exclusively through electronic means all notices, disclosures,
authorizations, acknowledgements, and other documents that are required to be provided
or made available to you by California Solar & Electric, Inc during the course of your
relationship with California Solar & Electric, Inc .