Loading...
HomeMy WebLinkAbout2701 S Poplar St - PlanPAGE REV: C1 1/14/2025 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 LAYOUT PV-3.2 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUPLOAD CALCS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE LTD: LR5-54HABB-395M TESLA: POWERWALL 3 1707000-XX-Y FOOT TO FRAMING, SNR-DC-00339 1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh TOTAL ENERGY CAPACITY (IN kWh): 27kWH EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS EXISITNG SOLAR SYSTEM INSTALLED BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL PANEL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). MODULES, ARE CLASS A FIRE RATED. CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) Bldg #101122234 Elect #20184913 APPROVALS: ELECT - CSG ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** 2701 S Poplar St 3/10/2025 /ce/ PAGE REV: B1 12/10/2024 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PLPLPL PL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP (E) DETACHED STRUCTURE ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS  IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE  SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET  EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE  DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE  FIRE TESTING. ARRAY  PITCH PV AREA  (SQFT) AR-01 17° 63.1 AR-02 17° 84.1 AR-03 17° 252.3270° 258° 90° TRUE  AZIM MAG  AZIM 168°180° 78° SITE PLAN - SCALE = 3/64" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 (N) ARRAY AR-03 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) SE MP GP (E) PV ARRAY(TYP) (E) PV EQUIPMENT S  P O P L A R   S T (E) FENCE (E) GATE(TYP) (E) CHIMNEY RSD INVAC MD POWERWALL ENERGY  STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANEL ELECTRIC VEHICLE  SUPPLY EQUPMENTEV MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE  INTERIOR EQUIPMENT  SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMA GROUNDING  ELECTRODE ENERGY STORAGE  SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE  1 COMMUNICATION  WIRESAM MD MICROGRID  INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEMPV LOAD CENTERLC LEGEND  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN RAIL STANDOFFS &  FOOTINGS SOLAR  MODULES RSD EXTERNAL RAPID SHUTDOWN SWITCH AC AC INVINV ROOF PATHWAYS (3' TYP) "NOTE: ROOFTOP MODULE LEVEL RAPID  SHUTDOWN DEVICE INSTALLED  PER CEC  690.12" NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 2606 SQFT.  TOTAL PV ARRAY AREA(E+N): 651.5 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 (E+N)= 25% A A A A A A A A AA A A B B B B C C C Exp. 12/31/2026Digitally Signed On: 12/31/24 2701 S Poplar St 3/10/2025 /ce/ PAGE REV: B1 12/10/2024 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL INSTALLED SECTION VIEW DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO RAFTERSNR-DC-00339 1 5 7 2019 NEW DETAIL 1 6 18 2019 DRO-00138 B 6 22 2023 DC002707 REV: ADATE: DNS 6 22 2023 DRAFTER:    M.AFFENTRANGER E.FERGUSON M.AFFENTRANGER Solar Mounting Solutions MJA MJA MJA BIN: 8 214" 112" 112" 158" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 516"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212" INTO STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING. REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE REFER TO SNAPNRACK INSTALLATION MANUAL FOR516"Ø HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447" STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. SNAPNRACK5 16"n UMBRELLA LAG SCREW, S.S. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL SNAPNRACK UMBRELLA FLASHING 212" MIN. EMBEDMENT INTO WOOD MEMBER MODULE HEIGHT OFF ROOF: UR-40: 338" - 438" UR-60: 4" - 5" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA LAG AND FLASHING SNAPNRACK UMBRELLA FLASHING MOUNTING DETAIL PV-3.2 Exp. 12/31/2026Digitally Signed On: 12/31/24 2701 S Poplar St 3/10/2025 /ce/ PAGE REV: B1 12/10/2024 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. UMBRELLA SCREW: 2.5" MIN EMBEDMENT INTO FRAMING PV-3.0 LAYOUT 4" SOLAR MODULE SNAPNRACK  RACKING MODULE ELEVATION DETAIL - SCALE: NTS INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED  PRIOR TO PROCEEDING W/ INSTALLATION. * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 180° PITCH: 17° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 90° PITCH: 17° ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 COMP SHINGLE - UR - UMBRELLA L  FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED AR-02 COMP SHINGLE - UR - UMBRELLA L  FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING, SNR-DC-00339 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED 5'-8" 3'-5" 8'-2" 3'-9" 11" 13'-11" 37'-4"17'-1"5'-7" 16'-6"7'-6"6'7'-6"15'-3" EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD  ROOF AND FREE FROM DAMAGE, DETERIORATION, OR  MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN  INTEGRITY. CONTACT ENGINEER OF RECORD IF FOLLOWING  MINIMUM REQUIREMENTS ARE NOT SATISFIED IN COMPLIANCE  WITH THE STATED RACKING DESIGN: Exp. 12/31/2026Digitally Signed On: 12/31/24 2701 S Poplar St 3/10/2025 /ce/ PAGE REV: B1 12/10/2024 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. UMBRELLA SCREW: 2.5" MIN EMBEDMENT INTO FRAMING 4" SOLAR MODULE SNAPNRACK  RACKING MODULE ELEVATION DETAIL - SCALE: NTS INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED  PRIOR TO PROCEEDING W/ INSTALLATION. * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE  EDGES (EXCEPT VALLEYS), THEN  ATTACHMENTS NEED TO BE ADDED AND  OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING  INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON  PLANS TO BE 1/5TH OF ALLOWABLE  ATTACHMENT SPACING INDICATED ON PLANS. ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-03 COMP SHINGLE - UR - UMBRELLA L  FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING, SNR-DC-00339 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED D3 - AR-03 - SCALE:1/8"=1'-0" AZIM: 270° PITCH: 17° 18'-10" 15'-2" 13'-7"8'-11" 1'-7" 1'-6" PV-3.1 LAYOUT EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD  ROOF AND FREE FROM DAMAGE, DETERIORATION, OR  MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN  INTEGRITY. CONTACT ENGINEER OF RECORD IF FOLLOWING  MINIMUM REQUIREMENTS ARE NOT SATISFIED IN COMPLIANCE  WITH THE STATED RACKING DESIGN: Exp. 12/31/2026Digitally Signed On: 12/31/24 2701 S Poplar St 3/10/2025 EXISTING 100A MAIN BREAKER END FED EXISTING 100A MAIN PANEL 100A  BUS M 100A (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3  TRL M NEW 200A BACKUP GATEWAY3 1841000-X1-Y 4 NEW 225 A GENERATION PANEL & BACKUP  LOAD PANEL (N)(1) 60A PV +ESS BREAKER (E)20A PV BREAKER  4 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 1 OF 12 MODULES 4  MODULE LEVEL RAPID SHUTDOWN DEVICES 12 POINT OF INTERCONNECTION:CEC 705.13 GATEWAY BREAKER AT OPPOSITE END OF BUSBAR METER NUMBER: 222013-515499 EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED(E+N) = 80A USED FOR INTERCONNECTION CALCULATIONS Existing Inverter(s)E ABB: PVI-3.0-OUTD-S-US-A (240 V) J-BOX 14 Kyocera Solar: KU265-6ZPA EE E E (E)  AC DISCONNECT KNIFE DISCONNECT E FACILITY  GROUND 5 (N) TESLA REMOTE METER  SOLAR CURRENT  TRANSFORMERS 1 LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 1 OF 4 MODULES 2  MODULE LEVEL RAPID SHUTDOWN DEVICES UL 9540  FACTORY WIRING  ASSEMBLY (1) TESLA POWERWALL 3 EXPANSION PACK 1807000-xx-y 1 LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 2 OF 3 MODULES 1  MODULE LEVEL RAPID SHUTDOWN DEVICES PAGE REV: D 2/27/2025 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PV-4.0 ELECTRICAL #ESTAMP POWER CONTROL SYSTEM (PCS): SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR  SUPPLIED BY THE POWER PRODUCTION SOURCES MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. WITH 240.6(C).  SETPOINTS:           - 80A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL           - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT)D 2701 S Poplar St 3/10/2025 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG  (PV WIRE)N/A 6 AWG (BARE)Open Air 2 Inverter Input (6) 10 AWG  THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Gateway Output (2) 3 AWG  THHN/THWN-2 (1) 3 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT 5 Backup Loads (13)  12AWG  THHN/THWN-2 (13)  12AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1-1/4 EMT (2)  10AWG  THHN/THWN-2 (1)  10AWG  THHN/THWN-2 8 AWG THHN/THWN-2 E EXISTING PAGE REV: D 2/27/2025 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP POWER CONTROL SYSTEM (PCS): SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR  SUPPLIED BY THE POWER PRODUCTION SOURCES MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. WITH 240.6(C).  SETPOINTS:           - 80A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL           - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) INSTALLER MUST CHECK THE CONDITION,  INSTALLABILITY AND CODE COMPLIANCE OF  EXISTING EQUIPMENT. CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER CONDUCTORS IN  TWO SEPARATE CONDUITS ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED  WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 PV-4.1 ELECTRICAL  CONTI GENERAL NOTES: COLD WATER GAS BOND D D 2701 S Poplar St 3/10/2025 PAGE REV: B1 12/10/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SYSTEM INFORMATION 7.505 KW DC PHOTOVOLTAIC SYSTEM (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y (7) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y SYSTEM OCPD SIZE (COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  112 A X 1.25 = 140 A → 70 A OVERCURRENT PROTECTION GATEWAY SYSTEM AC WIRE SIZING MAX AC OUTPUT CURRENT = 70 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 95A = 86.45A TERMINAL RATING[110.14(C)] = 4 AWG, 75°C RATED = 85A 85A < 86.45A   TERMINAL RATING GOVERNS CONDUCTOR SIZING 70A < 85A   4 AWG AMPACITY OK THEREFORE 4 AWG IS SUFFICIENT. ALLOWABLE BACKFEED MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = 100A 70A ≤ 100A→ INTERCONNECTION MEETS CEC 705.13 REQUIREMENTS. INVERTER INFORMATION 4740 KW DC PHOTOVOLTAIC SYSTEM (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  LOAD)[690.8(B)(1)]=  14.88A X 1.25 X 1.25 = 23.25A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A 35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 23.25A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)]  = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] = 6 AWG,  75°C RATED = 65A 65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  TEMP] + VOC} X (# MODULES / STRING) = {[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V} X 12 = 472.72 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.88 A X 1 = 18.6A INVERTER INFORMATION 2765 KW DC PHOTOVOLTAIC SYSTEM (7) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  LOAD)[690.8(B)(1)]=  14.88A X 1.25 X 1.25 = 23.25A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A 35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 23.25A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)]  = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] = 6 AWG,  75°C RATED = 65A 65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  TEMP] + VOC} X (# MODULES / STRING) = {[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V} X 4 = 157.57 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.88 A X 1 = 18.6A PV-4.2 ELECTRICAL CALCS 2701 S Poplar St 3/10/2025 BACKUP LOADS LOAD BREAKER RATING (AMPS)LABEL DEMAND LOAD 1 15A-1P LIGHTING/ RECEPTACLE 1500 W 2 15A-1P LIGHTING/ RECEPTACLE 1500 W 3 20A-1P LIVING ROOM 1500 W 4 20A-1P M BED OUT 1500 W 5 20A-1P LIGHTING/ RECEPTACLE 1500 W 6 20A-1P LIGHTING/ RECEPTACLE 1500 W 7 20A-1P LIGHTING/ RECEPTACLE 1500 W 8 20A-1P LIGHTING/ RECEPTACLE 1500 W 9 20A-1P LIGHTING/ RECEPTACLE 1500 W 10 20A-1P LIGHTING/ RECEPTACLE 1500 W 11 20A-1P LIGHTING/ RECEPTACLE 1500 W 12 20A-1P LIGHTING/ RECEPTACLE 1500 W 13 20A-1P LIGHTING/ RECEPTACLE 1500 W 14 30A-2P AC 4464 W PAGE REV: B1 12/10/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 BACKUP LOAD CALCS ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE PANEL. BACKED UP LOADS CALCULATION: (4464 VA)/ 240V = 18.6 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 18.6A. (MAX LOADS OUTPUT) X (CONTINUOUS LOADS) = 18.6 A X 1.25 = 23.25A BACKED UP LOADS PANEL BREAKER = 70A 23.25 A < 70A. THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. AC WIRE SIZING FOR BACKUP LOADS PANEL MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 18.6 A X 1.25 = 23.25 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A 35A < 36.4A TERMINAL RATING GOVERNS CONDUCTOR SIZING. 23.25A < 35A 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. PV-4.3 BACKUP LOAD CALCS 2701 S Poplar St 3/10/2025 PAGE REV: D 2/27/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 (N) GATEWAY  FEEDER BREAKER MAIN BREAKER10 0 NEW PV+ESS  BREAKER60 20 20 15  (N) 225A GENERATION  &BACKUPLOADS PANEL 20 20 20 20 20 LIVING ROOM 20 BATHROOM LIGHTS FUTURE 100/100A  MAIN PANEL PANEL SCHEDULE PANEL SCHEDULE PV-4.4 15 20 20 20 30 MASTER BED OUTLET BATHROOM OUTELTS AC UNIT BEDROOM 2 LIGHTS BEDROOM 2 OUTLETS BEDROOM 3 LIGHTS BEDROOM 3 OUTLETS GARAGE OUTLETS REFRIDGERATOR MASTER BED LIGHTS KITCHEN LIGHTS KITCHEN OUTLETS 20 10 0 D EXISTING PV  BREAKER D 2701 S Poplar St 3/10/2025 PAGE REV: B1 12/10/2024 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS: SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC 2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING:PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: 690.31(D)(2) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC 2022: 705.12(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 48 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT ENERGY STORAGE SYSTEM DISCONNECT LABEL LOCATION: ENERGY STORAGE SYSTEM DISCONNECT PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN ENERGIZED AFTER LOSS OF UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) CAUTION 2701 S POPLAR ST, SANTA ANA, CA, 92704 SOLAR PANELS ON ROOF PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER INVERTER AND ENERGY STORAGE (EXT)-PCS CONTROLLED AC DISCONNECT BACKUP GATEWAY SERVICE ENTRANCE AND GATEWAY FEEDER BREAKER (E) PV EQUIPMENT GENERATION AND BACKUP LOADS PANEL RAPID SHUTDOWN SWITCH (E)PV ARRAY RAPID SHUTDOWN DISCONNECT LOCATION (EXISTING SYSTEM AC DISCONNECT) PV SYSTEM(S) ARE EQUIPPED WITH RAPID SHUTDOWN DEVICE(S) 2701 S Poplar St 3/10/2025 PAGE REV: B1 12/10/2024 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.1 #ESTAMP MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT INVERTER 2 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE  BY CLAMP SIZE 4.25" X 0.75" INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING:  56 A   THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. LABEL LOCATION: BACKUP LOAD PANEL NO ADDITIONAL  LOADS TO BE  ADDED LABEL LOCATION: 120 240NOMINAL ESS VOLTAGE VAC MAIN PANEL. ENERGY STORAGE SYSTEM DISCONNECT NEC 2020 - PW2 PER CODE(S): NEC 706.15(C) 2701 S Poplar St 3/10/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] 2701 S Poplar St 3/10/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 4 1.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) 2701 S Poplar St 3/10/2025                      !  "  # $ $% &   !  " '() *$ ' *  " +  '  ,(-./)0    1'      * #1  $       1'  #    2 $" +)   $" +  %   #$% &  ! 1' )+  !  %     #    ' )      #2* $" +1   *   $" +      3 # 43  5 )6 57...*  57...&*  5#+# &8 ! 9 7 '" *      "   1  " "  %    5  # !     )+  9  *    7 ' :$" -  # ;.<2=><2? 0      (  1                           "    +             "     +           #    "    '        "   '   +          +       +               ,22  E  F  '"  "G         H *8 '  "   +    . Sep 16, 2020  5 .>-2=&>2? 0  .&2=2? %!  "   1    +    &2@9=2@? 2@9=2@?    +  /%-;  #  #   #'A3B1$% & 0  )  0%& 71C$><;;>>&< $".+ *#.  * # 8 # =" ?&.-2"=/)?=&.;2*#?   " 'D  '+#/)  *#/  * #  # .2=.>2?  * # 8 .>2=&;.<><2?  * #  # &.<2=<.>>2? ++ )  " ' )  " ++   7   %   # %  0    %  + +)3D %/)0  !   %/)0    1: !' + D  '+ D ) :  + D   ) #   )      !   )   = +  ) #   ? %!  0    %!  +  2701 S Poplar St 3/10/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547- 2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547- 2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547- 2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547- 2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B HIGH FREQUENCY RIDE- THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547- 2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547- 2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547- 2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547- 2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547- 2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547- 2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547- 2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547- 2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547- 2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547- 2018 VOLTAGE-ACTIVE POWER (VOLT- WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547- 2018 TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547- 2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547- 2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547- 2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547- 2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547- 2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547- 2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547- 2018 2701 S Poplar St 3/10/2025 2701 S Poplar St 3/10/2025 Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production,fast and ef𿿿cient installations,easy system expansion,and simple connection to any electrical service. 22024Powerwall 3 Datasheet Solar Technical Speci￿cations Maximum Solar STC Input 20 kW Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (Imp)13 A 5 Maximum Short Circuit Current per MPPT (Isc)15 A 5 Powerwall 3 Technical Specifications 1 Typical solar shifting use case. 2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. 3 Tested using CEC weighted ef𿿿ciency methodology. 4 The customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A ISC. Battery Technical Speci￿cations Nominal Battery Energy 13.5 kWh AC 2 Maximum Continuous Discharge Power 11.5 kW AC Maximum Continuous Charge Power 5 kW AC Output Power Factor Rating 0 -1 (Grid Code con𿿿gurable) Maximum Continuous Current 48 A Maximum Output Fault Current 10 kA Load Start Capability (1 s)185 A LRA Power Scalability Up to 4 Powerwall 3 units supported System Technical Speci￿cations Model Number 1707000-xx-y Nominal Grid Voltage (Input &Output)120/240 VAC Grid Type Split phase Frequency 60 Hz Overcurrent Protection Device 60 A Solar to Battery to Home/Grid Ef￿ciency 89% 1,2 Solar to Home/Grid Ef￿ciency 97.5% 3 Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4) Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certi𿿿ed switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years 2701 S Poplar St 3/10/2025 2701 S Poplar St 3/10/2025           !"#!$ %$&   ' ( )( *+ ,- ((* , . ) ./ ( *  00+&1&2!! % .  .3(  4 / *4   .  .3 #!5$   / . ( /( 671 .(   .3 %$&  ..  *8 ./ )(  ..   4    *. ((    (. %. .3*8 /  -) /(  (   (..  .3  * .3  .  ( * "( 3  .3  !"$  9 $:222$& (-.- $: 222$&88  -8( - . *  :;#2615--<72715.=  3  2#!5--<;2#&5.=  8 ;1215--<&2715.= 3 ..3 > &2;152-<&15()/2.=!2!!?!2!:5.@<2!6?12#5--@=$: 222$:!= &2;152-<&15()/2.=$: 222$:!= 12!652-< 15()/2.=!2!:5.@<62&75--@=$6= 12!652-< 15()/2.=!2!?!2!&5.@<:2&?:2:5--@=$#222$ = 12#152-<1!5()/2.=!2! 5.@<#2#75--@=$&=  .3 . 88.3 (  3*!!:!#AB%$&B&!!!$  .  ( :$   (  -  +         - .   .    .    . .       )    /   .     .     )     /      -  .  . 3    )  (  *      (  ) (  *   /   8       /    8   /       8 8 (     . Feb 3, 2020 : !!761;!: ;: ;:  , 3 4 3 <) =2::5,3< 2#15()<==  . )( *C . */3.%D //  . )( *  . )( //    . --8  (/. 88  .#1 $+  8  . E8 *  - ( .(.3+  .( -8. 4   ,.4.   / (/.     .3 .A 8 '  -2- ./- .3 44428#14 ..3 2 23' $  3( .$  (  . $ / /"C   ' -8( .  (  . E '*- (/ C % */ C  E -8 ../- .C  .  3( . .  (  .   '  .  (  .< / . ( 3 ( 8 = .'.- . ( (   .'.- . (/( (  */( . / 8 / *(.38  . .    (4  . *   . *:6-.  2701 S Poplar St 3/10/2025 32024Powerwall 3 Datasheet Mechanical Speci￿cations Dimensions 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) Weight 130 kg (287 lb) Mounting Options Floor or wall mount Powerwall 3 Technical Specifications Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m < 50 db(A) typical <62 db(A)maximum Compliance Information Certi￿cations UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 193 mm 1099 mm 42024Powerwall 3 Datasheet Electrical Speci￿cations Model MCI-1 MCI-2 Nominal Input DC Current Rating (IMP)13 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Speci￿cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X /IP65 NEMA 4X /IP65 RSD Module Performance Maximum Number of Devices per String 5 5 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Speci￿cations Electrical Connections MC4 Connector MC4 Connector Housing Plastic Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip Compliance Information Certi￿cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 7 Maximum System Voltage is limited by Powerwall to 600 V DC. UL 3741 PV Hazard Control (and PVRSA)Compatibility See Powerwall 3 Installation Manual 2701 S Poplar St 3/10/2025 52024Powerwall 3 Datasheet Gateway 3 8 Only Eaton CSR or BWH main breakers are 25 kA rated. Performance Speci￿cations Model Number 1841000-01-y Nominal Grid Voltage 120/240 V AC Grid Con￿guration Split phase Grid Frequency 60 Hz Continuous Current Rating 200 A Maximum Supply Short Circuit Current 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker 8 IEC Protective Class Class I Overvoltage Category Category IV Mechanical Speci￿cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 16.3 kg (36 lb) Mounting options Wall mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 107.1, CSA 22.2 29 Emissions FCC Part 15, ICES 003 — Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based control, and backup operation. 411 mm 660 mm 149 mm AC Meter Revenue accurate (+/- 0.5%) Communication CAN User Interface Tesla App Backup Transition Automatic disconnect for seamless backup Overcurrent Protection Device 100–200 A Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers Internal Panelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or Square D HOM breakers rated to 10–125A Warranty 10 years 62024Powerwall 3 Datasheet Backup Switch 9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Performance Speci￿cations Model Number 1624171-xx-y Continuous Load Rating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 9 Communication CAN AC Meter Revenue accurate (+/- 0.5%) Expected Service Life 21 years Warranty 10 years Mechanical Speci￿cations Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) Weight 2.8 lb Meter and Socket Compatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override 10 Reset button Conduit Compatibility 1/2-inch NPT Environmental Speci￿cations Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) Enclosure Rating NEMA 3R Pollution Rating PD3 Compliance Information Safety Standards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 Emissions FCC, ICES 10 Manually overrides the contactor position during a service event. — The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 204.86 74 176 mm 205 mm 74 mm 2701 S Poplar St 3/10/2025 72024Powerwall 3 Datasheet Backup Gateway 2 Performance Speci￿cations Model Number 1232100-xx-y AC Voltage (Nominal)120/240 V Feed-in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short Circuit Current 10 kA 11 Overcurrent Protection Device 100 - 200 A, Service entrance rated 9 Overvoltage Category Category IV Internal Primary AC Meter Revenue accurate (+/- 0.2%) Internal Auxiliary AC Meter Revenue accurate (+/- 2%) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G) 12 Mechanical Speci￿cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-Bush mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 411 mm 660 mm 149 mm 11 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 12 Cellular connectivity subject to network operator service coverage and signal strength. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. In this system con𿿿guration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled. User Interface Tesla App Operating Modes Support for solar self- consumption, time-based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 82024Powerwall 3 Datasheet Powerwall 3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup 2701 S Poplar St 3/10/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 2701 S Poplar St 3/10/2025 Service Voltage 240 Section 220.83 Existing Dwelling Unit Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.4 4896 Part #2 - Section 220.83(B)(2), (3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 1500 1500 1000 600 1000 1600 Amps Box B (VA) 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B = 13596 Total VA 13596 First 8000 VA @ 100% 8000 Remaining VA @ 40% Remaining VA = 5596 5596 x 40% = 2238.4 VA Adding First 8000 VA, if possible 8000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits: 10238.4 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits: 42.66 Amps Part #3 - Section 220.83(B) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:4,464 VA 100% of all the Heating or A/C loads in Amps:18.60 A VA Volts Amps Parts #1 & #2 10238.4 240 42.66 Part #3 4,464 240 18.60 Total VA for all Parts: 14,702 Totals Service/Feeder Load 61.26 Dedicated circuit Dedicated circuit Article 220 - Dedicated Backup Panel Calculation Job Code 2701 S Poplar St Santa Ana, CA 92704 109R-701MEN1 Building Square Footage VA (watts)Amps House 1632.00 4896 20.40 Total for Part #1: Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Totals for Part #2: Totals from all Parts 2701 S Poplar St 3/10/2025 Service Voltage 240 Section 220.82 Dwelling Unit Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.4 4896 Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 1500 1500 1000 600 1000 1600 Amps Box B (VA) 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =13596 Total VA 13596 First 10000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =3596 3596 x 40% =1438.4 VA Adding First 10000 VA, if possible 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:11438.4 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:47.66 Amps Part #3 - Section 220.82(C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:4,464 VA 100% of all the Heating or A/C loads in Amps:18.60 A VA Volts Amps Parts #1 & #2 11438.4 240 47.66 Part #3 4,464 240 18.60 Total VA for all Parts:15,902 Totals Service/Feeder Load 66.26 Dedicated circuit Dedicated circuit Article 220 - Dedicated Backup Panel Calculation Job Code 2701 S Poplar St Santa Ana, CA 92704 109R-701MEN1 Building Square Footage VA (watts)Amps House 1632.00 4896 20.40 Total for Part #1: Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Totals for Part #2: Totals from all Parts 2701 S Poplar St 3/10/2025 Section 220.83 Existing Dwelling Unit Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.4 4896 Part #2 - Section 220.83 (B)(2),(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A N/A N/A N/A N/A N/A N/A N/A Amps Box B (VA) N/A 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =13596 Total VA 13596 First 8,000 VA @ 100%8000 Remaining VA @ 40% Remaining VA =5596 5596 x 40% =2238.4 VA Adding First 8000 VA 8000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:10238.4 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:42.66 Amps Part #3 - Section 220.83 (B) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:4,464 VA 100% of all the Heating or A/C loads in Amps:18.60 A VA Volts Amps Parts #1 & #2 10238.4 240 42.66 Part #3 4,464 240 18.60 Total VA for all Parts:14,702 Totals Service/Feeder Load 61.26 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 1632 Article 220 - Service/Feeder calculation for (address): 2701 S Poplar St Santa Ana, CA 92704 Building VA (watts) 4896 Amps 20.4 Job Code 109R-701MEN1 Totals from all Parts Dedicated circuit Total for Part #1: Refrigerator(s) Microwave(s) Totals for Part #2: Dryer Range Oven Pool Equipment 2701 S Poplar St 3/10/2025 Bus Rating:100 Main Rating:100 0%0% Not Fed by other panels Feeds: Panel 2 61.26 0.00 61.26 Bus Rating:225 Main Rating:70 100%100% Itemized House and 240V Loads for Panel: (VA) 1500 1500 1500 1000 600 1000 1600 4464 Fed by: Panel 1 61.26 61.26 Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Load Calc: (This Panel) Total Load Calc: Panel 2 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Laundry Appliance Circuit - 1 Total Load Calc: Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave A/C Unit - 240V Load Calc: (This Panel) 2701 S Poplar St 3/10/2025 City of Santa Ana, SIGNATURE:___________________ DATE:__________ 717 17th Street, Ste. 200 | Denver, CO 80202  I, Isidro Mendoza, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar on my residence located at 2701 s popular st , SANTA ANA, CA, 92704. Docusign Envelope ID: 07FB0F4F-DB5E-48FE-BEDB-560D4E23E344 12/20/2024 2701 S Poplar St 3/10/2025 Certificate Of Completion Envelope Id: 07FB0F4F-DB5E-48FE-BEDB-560D4E23E344 Status: Completed Subject: Complete with Docusign: Isidro Mendoza.Solar Authorization Letter (1).pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Stephanie Phillips AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 stephanie.phillips@sunrun.com IP Address: 68.119.159.122 Record Tracking Status: Original 12/17/2024 3:25:21 PM Holder: Stephanie Phillips stephanie.phillips@sunrun.com Location: DocuSign Signer Events Signature Timestamp Isidro Mendoza isidroamendoza94@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 172.1.155.184 Signed using mobile Sent: 12/17/2024 3:26:18 PM Resent: 12/19/2024 1:50:57 PM Viewed: 12/20/2024 4:38:49 PM Signed: 12/20/2024 4:39:23 PM Electronic Record and Signature Disclosure: Accepted: 8/11/2024 7:38:38 PM ID: c01db57d-2018-4fbc-819e-0348fc13a4f3 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 12/17/2024 3:26:18 PM Certified Delivered Security Checked 12/20/2024 4:38:49 PM Signing Complete Security Checked 12/20/2024 4:39:23 PM Completed Security Checked 12/20/2024 4:39:23 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure 2701 S Poplar St 3/10/2025 CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Isidro Mendoza 2701 S Poplar St 3/10/2025 How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X 2701 S Poplar St 3/10/2025 Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute 2701 S Poplar St 3/10/2025 the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. 2701 S Poplar St 3/10/2025 Rev: 8/29/19 Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST Print Name: CA CL #750184 (C10, C46) SUNRUN SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: CAITLYN HERNANDEZ 385-400-5019 Caitlyn.hernandez@sunrun.com 2701 s poplar st Santa ana Ca 92704 1.14.25 2701 S Poplar St 3/10/2025 PAGE REV: C1 1/14/2025 ISIDRO MENDOZA 2701 S POPLAR ST, SANTA ANA,  CA, 92704 PROJECT NUMBER:   109R-701MEN1 SHEET DESIGNER: VISHNUMAYA KP CUSTOMER RESIDENCE: TEL. (714) 697-7230 APN: 140-273-07 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 LAYOUT PV-3.2 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUPLOAD CALCS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE LTD: LR5-54HABB-395M TESLA: POWERWALL 3 1707000-XX-Y FOOT TO FRAMING, SNR-DC-00339 1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh   TOTAL ENERGY CAPACITY (IN kWh): 27kWH EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION  DETAILS EXISITNG SOLAR SYSTEM INSTALLED BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL  PANEL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). MODULES, ARE CLASS A FIRE RATED. CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) 2701 S Poplar St 3/10/2025