Loading...
HomeMy WebLinkAbout438 E Adams - PlanWALL PARALLEL TO JOIST BWALL PERPENDICULAR TO JOIST A PERPENDICULAR CTO JOIST PARALLEL DTO JOIST · 8'-0" MAX. OPENING SHEET DRAWN : SCALE: DATE : TITLE PR O P O S E D P R O J E C T : REVISIONS LM IT IS TO THE CLIENT'S LIABILTY TO REPORT ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSION & EXISTING CONDITIONS AS TO SATISFY APPLICABLE ZONING AND BUILDING REGULATIONS. AS A N I N S T R U M E N T O F P R O F E S S I O N A L S E R V I C E , T H I S D O C U M E N T A N D C O N T E N T S W I T H I N A R E T H E I N T E L L E C T U A L A N D P H Y S I C A L P R O P E R T Y O F L O M A D E S I G N + E N G I N E E R I N G . IT'S USE IS ONLY AUTHORIZED FOR THE PURPOSE OF THIS SPECIFIC PROJECT AND MAY NOT BE USED, REPRODUCED, DUPLICATED, OR IMPLEMENTED IN ANY WAY FOR ANY OTHER PROJECT AND/OR CLIENT. 43 8 E A D A M S S T , SA N T A A N A C A 9 2 7 0 7 AD A M S S T B A T H R O O M LOMA | D+E 626-344-7543 LOMADESIGNENGINEERING@ GMAIL.COM 1ST SUBMITTAL - XX.XX.24 FEB 12, 2025 1/4"=1'-0" A-4 DETAILS 438 E Adams 4/17/2025 PROPOSED SITE PLAN N1/8" = 1' STORM WATER POLLUTION CONTROL: Construction means constructing, clearing, grading or excavation that result in soil disturbance. Construction includes structure teardown (demolition). It does not include routine maintenance to maintain original line and grade, hydraulic capacity, or original purpose of facility; emergency construction activities required to immediately protect public health and safety; interior remodeling with no outside exposure of construction material or construction waste to storm water; mechanical permit work; or sign permit work. (Order No. 01-182, NPDES Permit No. CAS004001 – Part 5: Definitions) 1. Eroded sediments and pollutants shall be retained on site and shall not be transported from the site via sheet flow, swales, area drains, natural drainage or wind. 2. Stockpiles of earth and other construction-related materials shall be covered and/or protected from being transported from the site by wind or water. 3. Fuels, oils, solvents and other toxic materials must be stored in accordance with their listing and shall not contaminate the soil nor the surface waters. All approved toxic storage containers are to be protected from the weather. Spills must be cleaned up immediately and disposed of properly and shall not be washed into the drainage system. 4. Non-storm water runoff from equipment and vehicle washing and any other activity shall be contained on the project site. 5. Excess or waste concrete may not be washed into the public way or any drainage system. Provisions shall be made to retain concrete waste on-site until it can be appropriately disposed of or recycled. 6. Trash and construction –related solid wastes must be deposited into a covered receptacle to prevent contamination of storm water and dispersal by wind. 7. Sediments and other materials shall not be tracked from the site by vehicle traffic. The construction entrance roadways must be stabilized so as to inhibit sediments from being deposited into the street/public ways. Accidental depositions must be swept up immediately and may not be washed down by rain or by any other means. 8. Retention basins of sufficient size shall be provided to retain storm water runoff on-site and shall be properly located to collect all tributary site runoff. 9. Where retention of storm water runoff on-site is not feasible due to site constraints, runoff may be conveyed to the street and the storm drain system provided that an approved filtering system is installed and maintained on-site during the construction duration. LEGEND EXISTING (E) CHAIN LINK/ WOOD FENCE (E) CMU WALL NEW DEMO special hazards: 1. Glazing in hazardous locations shall be tempered. (CRC R308) Fixed or operable panels in swinging, sliding and bifold doors and fixed or operable panels adjacent to doors; Fixed or operable window panels with panes larger than 9 square feet and are less than 18 inches above the floor, have a top edge greater than 36 inches above the floor and have one or more walking surfaces within 36 inches, measured horizontally and in a straight line, of the glazing. Glazing in guards and railings, adjacent to wet surfaces, adjacent to stairs and ramps, and adjacent to bottom stair landings. 2. Each light of safety glazing material installed in hazardous locations shall be identified by a permanent label that specifies the labeler, and states that safety glazing material has been utilized in such installations. 4. Pre-fab fireplaces are required to have manufacturer, model, and Underwriter Laboratories certification (or ICC). 6. An approved Seismic gas shutoff valve will be installed on the fuel gas line on the down stream side of the utility meter and be rigidly connected to the exterior of the building or structure containing the fuel gas piping.”(Per Ordinance 171,874-for work over $10,000.) 7. Water heater must be strapped to wall. Section 508.2, LAPC. See Information Bulletin P/PC 2011-003 “How to Brace Your Water Heater” for details. 10. Smoke detectors shall be provided for all dwelling units intended for human occupancy, upon the owner's application for a permit for alterations, repairs, or additions, exceeding one thousand dollars ($1,000). (R314.6.2) 11. An approved smoke alarm shall be installed in each sleeping room & hallway or area giving access to a sleeping room, and on each story and basement for dwellings with more than one story. Smoke alarms shall be interconnected so that actuation of one alarm will activate all the alarms within the individual dwelling unit. In new construction smoke alarms shall receive their primary power source from the building wiring and shall be equipped with battery back up and low battery signal. (R314) 12. An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel-burning appliances are installed and in dwelling units that have attached garages. Carbon monoxide alarm shall be provided outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s) and on every level of a dwelling unit including basements. (R315) 13. Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel-burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. (R315.2.2) 14. 50 percent of nonhazardous construction and demolition waste shall be recycled and/or salvaged for reuse in accordance with the California Green Building Code, Chapter 4, Division 4.4. (R324) (E) 1122 SQ. FT. SINGLE FAMILY DWELLING 48' 48' 13 6 . 9 ' 14 0 . 2 ' E ADAMS ST 4'-1" 3'-8" 3'-8" 54 ' - 4 " 57 ' - 1 " 44 ' - 9 " 49 ' - 9 " 4'-1" SHEET DRAWN : SCALE: DATE : TITLE PR O P O S E D P R O J E C T : REVISIONS LM IT IS TO THE CLIENT'S LIABILTY TO REPORT ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSION & EXISTING CONDITIONS AS TO SATISFY APPLICABLE ZONING AND BUILDING REGULATIONS. AS A N I N S T R U M E N T O F P R O F E S S I O N A L S E R V I C E , T H I S D O C U M E N T A N D C O N T E N T S W I T H I N A R E T H E I N T E L L E C T U A L A N D P H Y S I C A L P R O P E R T Y O F L O M A D E S I G N + E N G I N E E R I N G . IT'S USE IS ONLY AUTHORIZED FOR THE PURPOSE OF THIS SPECIFIC PROJECT AND MAY NOT BE USED, REPRODUCED, DUPLICATED, OR IMPLEMENTED IN ANY WAY FOR ANY OTHER PROJECT AND/OR CLIENT. 43 8 E A D A M S S T , SA N T A A N A C A 9 2 7 0 7 AD A M S S T B A T H R O O M LOMA | D+E 626-344-7543 LOMADESIGNENGINEERING@ GMAIL.COM 1ST SUBMITTAL - XX.XX.24 FEB 12, 2025 1/8"=1'-0" A-1 SITE PLAN Bldg #101122119 APPROVALS: PLNG - C. Santana BLDG - G. Huang PUBLIC WORKS - Y. Soto 438 E Adams 4/17/2025 NTS T-1 TITLE SHEET LEGEND EXISTING NEW DEMO (E) FLOOR PLAN 1/4" = 1' LEGEND ELECTRICAL S S.D.C.M.D (N) FLOOR PLAN 1/4" = 1' (E) BEDROOM (E) LAUNDRY ROOM (E) BATHROOM (E) KITCHEN (E) LIVING ROOM (E) GARAGE (E) DINING AREA (E) BEDROOM (E) HALLWAY (E) CLOSET (E) BEDROOM (E) LAUNDRY ROOM (E) BATHROOM (E) KITCHEN (E) LIVING ROOM (E) GARAGE (E) DINING AREA (E) HALLWAY (E) CLOSET (E) CLOSET SS SS GENERAL NOTES: 1. The construction shall not restrict a five-foot clear and unobstructed access to any water or power distribution facility (Power poles, pull-boxes, transformers, vaults, pumps, valves, meters, appurtenances, etc.) or to the location of the hook-up. The construction shall not be within ten feet of any power lines -whether or not the lines are located on the property. Failure to comply may cause construction delays and/or additional expenses." 2. Obtain permits from Public Works prior to Construction for: a. Temporary pedestrian protection b. For any construction near any street or public area. 5. Every space intended for human occupancy shall be provided with natural light by means of exterior glazed openings in accordance with Section R303.1 or shall be provided with artificial light that is adequate to provide an average illumination of 6 foot-candles over the area of the room at a height of 30 inches above the floor level. (R303.1) 6. A copy of the evaluation report and/or conditions of listing shall be made available at the job site. 7. Plumbing fixtures are required to be connected to a sanitary sewer or to an approved sewage disposal system (R306.3) 8. Kitchen sinks, lavatories, bathtubs, showers, bidets, laundry tubs and washing machine outlets shall be provided with hot and cold water and connected to an approved water supply (R306.4) 13. A minimum of 50 percent of the nonhazardous construction and demolition waste shall be recycle and/or salvage for reuse in accordance with California Green Building Standards Code, Chapter 4 Division 4.4. (R324) 14. Finish materials including adhesives, sealants, caulks, paints and coating, aerosol paints and systems and composite wood products shall meet the volatile organic compound (VOC) emission limits in accordance with the California Green Building Standards Code, Chapter 4 Division 4.5. (R330) 15. a vapor retarder is required, a capillary break shall be installed in accordance with the California Green Building Standards Code, Chapter 4, Division 4.5. (R506.2.3.1) 16. Annular space around pipes, electric cables, conduits or other openings in bottom/sole plates at exterior walls shall be protected against the passage of rodents by closing such openings in accordance with the California Green Building Standards Code, Chapter 4, Division 4.4. (R602.3.4.1) 17. Architectural paints and coatings shall comply with VOC limits in Table 1 of the Air Resources Board Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings catergories listed in Table 4.504.3 shall be determined by classifying the coating as Flat, Nonflat, or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37, of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat, or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply (CALGREEN 4.504.2.2) MEANS OF EGRESS: 1. provide 32" wide doors to all interior accessible rooms within a dwelling unit.(larc section r311.2, labc section 6304.1) 2. provide emergency egress from sleeping rooms. min.- 24" clear ht, 20" clear width, 5.7 sq.ft. min. area. (larc section r310, labc section 1029) 3. occupied roofs shall be provided with exits as required for stories. ELECTRICAL NOTES: 1. Recessed lights shall be IC and AT rated. 2.All in ceiling recessed downlight luminaires must not have screw bulb sockets and meet the following requirements: a. must be defined per Section 110.1 for zero clearance insulation contact, IC-rated. b. Airtight certified with air leakage less than 2.0 cfm at 75 pascals, and sealed with a gasket or caulk between housing and ceiling. c. All air leaks paths between conditioned and unconditioned spaces shall be sealed with a gasket or caulking. d. Allow ballast or driver maintenance and replacement to be readily accessible from under ceiling for luminaires with hardwired ballasts or drivers. e. Contain light sources that comply w/ JA8 bulbs 1. Electronic ballasts for fluorescent lamps > 13 watts shall be electronic with an output frequency > 20kHAll 2. No limit to watts but must be 100% high efficiency dimmable or on a vacancy sensor BATHROOMS: 1. All shower enclosures, regardless of shape, shall have a minimum finished interior area of not less than 1024 square inches (0.66 m2) and shall be capable of encompassing a30 inch diameter (0.76 m) circle. The minimum area and dimensions shall be maintained to a point 70 inches (1.8 m) above the shower drain outlet. (Plumbing CodeSection 410.4) 2. Bathtub and shower floors, walls above bathtubs with a showerhead, and shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to a height of not less than 6 feet above the floor (R307.2). 3. Provide ultra low flush water closets for all new construction. Existing shower heads and toilets must be adapted for low water consumption. 4. A min 12" sq. access panel to the bathtub trap slip joint connection is required.(Plumbing Code Section 405.2) 5. All shower doors and windows less than 60" from shower or bathtub to be tempered glass 6. Plumbing fixtures and fittings shall comply with the following: CALGREEEN RESIDENTIAL MANDATORY MEASURES 4.303.1.1 Water Closets: ≤ 1.28 gal/flush 4.303.1.3.1 Single Showerheads: ≤ 1.8 gpm @ 80 psi 4.303.1.4.1 Residential Lavatory Faucets: Maximum Flow Rate ≤ 1.2 gpm @ 60 psi; Minimum Flow Rate ≥ 0.8 gpm @ 20 psi PROVIDE ENERGY STAR EXHAUST FAN w/HUMIDTY SENSING SWITCH (50 CFM MIN.) A A-4 TYP. B A-4 S.D. (E) CLOSET (E) CLOSET (E) CLOSET (E) CLOSET S.D.C.M.D S.D.C.M.D S.D.C.M.D (N ) 4 x 8 H D R (N) CLOSET SHEET DRAWN : SCALE: DATE : TITLE PR O P O S E D P R O J E C T : REVISIONS LM IT IS TO THE CLIENT'S LIABILTY TO REPORT ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSION & EXISTING CONDITIONS AS TO SATISFY APPLICABLE ZONING AND BUILDING REGULATIONS. AS A N I N S T R U M E N T O F P R O F E S S I O N A L S E R V I C E , T H I S D O C U M E N T A N D C O N T E N T S W I T H I N A R E T H E I N T E L L E C T U A L A N D P H Y S I C A L P R O P E R T Y O F L O M A D E S I G N + E N G I N E E R I N G . IT'S USE IS ONLY AUTHORIZED FOR THE PURPOSE OF THIS SPECIFIC PROJECT AND MAY NOT BE USED, REPRODUCED, DUPLICATED, OR IMPLEMENTED IN ANY WAY FOR ANY OTHER PROJECT AND/OR CLIENT. 43 8 E A D A M S S T , SA N T A A N A C A 9 2 7 0 7 AD A M S S T B A T H R O O M LOMA | D+E 626-344-7543 LOMADESIGNENGINEERING@ GMAIL.COM 1ST SUBMITTAL - XX.XX.24 FEB 12, 2025 1/4"=1'-0" A-2 FLOOR PLAN 438 E Adams 4/17/2025 PROPOSED SOUTH ELEVATION 0'-0" 8'-0" CLG. WIND./DR. 6'-8" 6" MIN 0'-0" 8'-0" CLG. WIND./DR. 6'-8" 6" MIN PROPOSED WEST ELEVATION LEGEND 4' - 8 " 2' - 8 " SHEET DRAWN : SCALE: DATE : TITLE PR O P O S E D P R O J E C T : REVISIONS LM IT IS TO THE CLIENT'S LIABILTY TO REPORT ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSION & EXISTING CONDITIONS AS TO SATISFY APPLICABLE ZONING AND BUILDING REGULATIONS. AS A N I N S T R U M E N T O F P R O F E S S I O N A L S E R V I C E , T H I S D O C U M E N T A N D C O N T E N T S W I T H I N A R E T H E I N T E L L E C T U A L A N D P H Y S I C A L P R O P E R T Y O F L O M A D E S I G N + E N G I N E E R I N G . IT'S USE IS ONLY AUTHORIZED FOR THE PURPOSE OF THIS SPECIFIC PROJECT AND MAY NOT BE USED, REPRODUCED, DUPLICATED, OR IMPLEMENTED IN ANY WAY FOR ANY OTHER PROJECT AND/OR CLIENT. 43 8 E A D A M S S T , SA N T A A N A C A 9 2 7 0 7 AD A M S S T B A T H R O O M LOMA | D+E 626-344-7543 LOMADESIGNENGINEERING@ GMAIL.COM 1ST SUBMITTAL - XX.XX.24 FEB 12, 2025 1/4"=1'-0" A-3 ELEVA- TIONS 438 E Adams 4/17/2025 SFD: ADAMS ST BATHROOM 438 E ADAMS ST, SANTA ANA CA 92707 TEAM CONTACTS OWNER: LAURA CASTANEDA 438 E ADAMS ST SANTA ANA, CA 92707 DESIGNER/ CONTACT: SITE DATA PROJECT ADDRESS: A.P.N.: 016-083-16 SCOPE OF WORK: NEW BATHROOM WITHIN EXISTING ENVELOPE OF EXISTING SFD. LEGAL DESCRIPTION: TR A39 LOT 4 BLK YEAR BUILT: 1960 PARCEL MAP (nts) SITE MAP STORIES: 1 HEIGHT: ~25' CODE DATA 2022 CBC / 2022 CRC 2022 CEC 2022 CMC 2022 CPC 2022 CEC (ENERGY) R2 ZONING: OCCUPANCY: SINGLE FAMILY RESIDENCE AREAS (E) AREAS: (E) HOUSE - 1117 SQ FT "ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES TO INCLUDE LOCAL AMENDMENTS": 6,651 SQ FT LOT AREA: CONSTRUCTION TYPE: SINGLE DWELLING TYPE V-B NO SPRINKLERS TOTAL = 1357 SQ FT TOTAL AREAS: LOT AREA - 6651 SQ FT FLOOR AREA - 1357 SQ FT FAR - 21% PLAN INDEX PROJECT INFO PROJECT INFO MAPS NOTES "ALL WORK IN THE PUBLIC RIGHT-OF-WAY SHALL BE DONE PER CITY STANDARDS" TITLE SHEET SITE PLAN FLOOR PLANS T-1 A-2 A-1 LOMA DESIGN+ENGINEERING LEO MAURICIO (626) 344-7543 LOMADESIGNENGINEERING @GMAIL.COM (E) GARAGE - 240 SQ FT A-4 DETAILS 438 E ADAMS ST SANTA ANA, CA 92707 NO HAZARDOUS MATERIALS TO BE STORED ON SECOND STORY STORAGE AREA. ONLY PERSONAL ITEMS TO BE STORED IN STORAGE AREA. A-3 ELEVATIONS SS SS PROVIDE ENERGY STAR EXHAUST FAN w/HUMIDTY SENSING SWITCH (50 CFM MIN.) A A-4 TYP. B A-4 S.D. S.D.C.M.D (N ) 4 x 8 H D R (N) CLOSET SHEET DRAWN : SCALE: DATE : TITLE PR O P O S E D P R O J E C T : REVISIONS LM IT IS TO THE CLIENT'S LIABILTY TO REPORT ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSION & EXISTING CONDITIONS AS TO SATISFY APPLICABLE ZONING AND BUILDING REGULATIONS. AS A N I N S T R U M E N T O F P R O F E S S I O N A L S E R V I C E , T H I S D O C U M E N T A N D C O N T E N T S W I T H I N A R E T H E I N T E L L E C T U A L A N D P H Y S I C A L P R O P E R T Y O F L O M A D E S I G N + E N G I N E E R I N G . IT'S USE IS ONLY AUTHORIZED FOR THE PURPOSE OF THIS SPECIFIC PROJECT AND MAY NOT BE USED, REPRODUCED, DUPLICATED, OR IMPLEMENTED IN ANY WAY FOR ANY OTHER PROJECT AND/OR CLIENT. 43 8 E A D A M S S T , SA N T A A N A C A 9 2 7 0 7 AD A M S S T B A T H R O O M LOMA | D+E 626-344-7543 LOMADESIGNENGINEERING@ GMAIL.COM 1ST SUBMITTAL - XX.XX.24 FEB 12, 2025 NTS T-1 TITLE SHEET 438 E Adams 4/17/2025