Loading...
HomeMy WebLinkAboutHISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 - PlanSHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A1 PROJECT DATA 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U 1012 & 1014 W THIRD ST., SANTA ANA, CA 92703 SCOPE OF WORK: 1. CONVERT (E) 900 SF 4-CAR GARAGE INTO 2 ADUs; 1 BED AND BATH EACH 2. LEGALIZE UNPERMITTED PATIO DATA: THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) 2022 CALIFORNIA BUILDING CODE (CBC) CODE REQUIREMENTS: THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE INDEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND OR OBTAINPERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONALSAFETY AND HEALTH (CAL/OSHA). THIS PERMIT AND ANY OTHER SAFETYPERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK. CAL/OSHA NOTE: 1. 2. 3. a. b. c. 65% OF NONHAZARDOUS CONSTRUCTION AND DEMOLITIONDEBRIS SHALL BE SALVAGED, RECYCLED, AND/OR RESUSED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATERDAMAGAE SHALL NOTE BE INSTALLED.WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHENTHE FRAMING MEMEBERS EXCEED19% MOISTURE CONTENT. INSULATION PRODUCTS WHICH AREVISIBLY WET OR HAVE HIGH MOISTURE CONTENT SHALL BEREPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE INWALLOR FLOOR CAVITIES (CGBSC 4.505.3) PROJECTS, WHICH DISTURB LESS THAN 1-ACRE OR SOILD ANDARE NOT PART OF LARGER DEVELOPMENTS THAT DISTURBMORE THAN 1-ACRE, SHALL MANAGE STORM WATER DRAINAGEDURING CONSTRUCTION. THE FOLLOWING MEASURES MAY BEIMPLEMENTED TO PREVENT FLOODING OF ADJACENTPROPERTIES, PREVENT EROSION, AND RETAIN SOIL RUNOFF ONTHE SITE: WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGESYSTEM, COLLECTION POINT, GUTTER, OR SIMILAR DISPOSALMETHOD, WATER SHALL BE FILTERED BY US OF A BARRIERSYSTEM, WATTLE, OR OTHER METHOD APPROVED BY THEENFORCING AGENCY. COMPLIANCE WITH A LAWFULLY ENACTED STORM WATERMANAGEMENT ORDINANCE RETENTION BASINS OF SUFFICIENT SIZE SHALL BE UTILIZEDTO RETAIN STORM WATER ON THE SITE. CALGREEN NOTES:SHEET INDEX NO. SHEET SHEET NAME 1 A1 PROJECT DATA 2 A2 SITE PLAN 3 A3 EXISTING HOUSE 4 A4 PROPOSED ADU FLOOR & ROOF PLAN 5 A5 PROPOSED ELECTRICAL PLAN 6 A6 ADU ELEVATIONS & SECTION 7 A7 EROSION & SEDIMENT CONTROL PLAN 8 A8 EXISTING & PROPOSED CONTOUR MAP 9 A9 SINGLE FAMILY RESIDENTIAL MANDATORY REQUIREMENTS 10 A10 FRAME BACKING FOR FUTURE GRAB BAR INSTALLATIONS 11 AD.1 ARCHITECTURAL DETAILS 12 AD.2 ARCHITECTURAL DETAILS 13 CG.1 CAL. GREEN REQUIREMENTS 14 CG.2 CAL GREEN REQUIREMENTS 15 S-1 FOUNDATION PLAN 16 S-2 FRAMING PLAN (ADU) 17 SD1 STRUCTURAL DETAILS 18 T24-1 TITLE 24 SHEET 19 T24-2 TITLE 24 SHEET 1. 2. 3. 4. 5. 6. 7. 8. PLANNING CLEARANCE REQUIRED FOR OVERHEAD SERVICE LINE. “PV IS A DEFERRED APPROVAL AND BUILDING CANNOT BE OCCUPIED UNTIL PV IS APPROVED BY CITY.” NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURAL STYLE, BUILDING MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND DESIGN. RECOMPACT 4’ OVER EXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATION INSPECTION. DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRED. PROVIDE 5” SLAB ON GRADE REINFORCED WITH #4 AT 18” ON CENTERS EACH WAY OVER 4” BASE OF ½” OR LARGER CLEAN AGGREGATE WITH 10 MIL VAPOR RETARDER INDIRECT CONTACT WITH CONCRETE. SLAB SHALL BE TIED-IN TO CONTINUOUS 12” WIDEX 24” (MINIMUM EMBEDMENT INTO FIRM SOIL) FOUNDATION. CONTINUOUS FOUNDATION MUST BE REINFORCED WITH 2 #5 (OR 3 #4) TOP AND BOTTOM. ALL CONCRETE SHALL BE FC’=4,500 PSI (MINIMUM) WITH TYPE V CEMENT MAXIMUM WATER CEMENT RATIO OF 0.45. NO SPECIAL INSPECTION REQUIRED IF CONCRETE TRUCK MIX TICKET IS PROVIDED. MECHANICAL, ELECTRICAL, AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. THE BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS REVISIONS REQUIRED BY ANY NON-CITY UTILITY COMPANY. IT IS SOLELY ON THE CONTRACTOR TO ENSURE PROPOSED ADDITION OR ALTERATION CAN AND WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE SPUBJECT TO BUILDING FIELD INSPECTION, GENERAL NOTES: JOB LOCATION SUBJECT PROPERTY IS 0.2 MILES TO THE NEAREST BUS STOP AREA LIVING (SF) GARAGE (SF) PORCH (SF) BEDROOM BATHROOM (E) UNIT #1014 640.5 450 0 2 1 (E) UNIT #1012 544.5 450 0 1 1 (N) ADU UNIT #A 450 -450 0 1 1 (N) ADU UNIT #B 450 -450 0 1 1 TOTAL 2085 0 0 5 4 LOT COVERAGE 2485 LOT SIZE 5250 % OF LOT COVERAGE 47.33% NOT TO SCALE PROJECT LOCATION EXISTING + ADU + GARAGE + PORCH DIG ALERT (811) TO BE CONTACTED AND THAT COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE WITH THE GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING PLACE. OWNER/S : HUGO PRADO PARCEL NUMBER : 0405-163-17 LOT SIZE : 5250 SF ZONE : R1 CONTACT NUMBER : 310-955-6409 EMAIL ADDRESS : only_hp@hotmail.com TYPE OF CONSTRUCTION ; V-B OCCUPANCY : R-3 VHFHSZ : NO FLOOD ZONE : X a. (N) ADU #1/SFD = 450 SF/1,185 SF = 38% (N) ADU #2/SFD = 450 SF/1,185 SF = 38% b. THE ADU SF/ SFD SF RATIO IS FOR PARK & REC. FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN SFR SF OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN SFR SF. RE V I S I O N T A B L E No . D A T E RE V I S E D B Y DE S C R I P T I O N Bldg #'s 101121802-03 & 05 APPROVALS: PLNG - F. Arias BLDG - J. Lo POLICE - B. Martin PUBLIC WORKS - Y. Soto HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A10 FRAME BACKING FOR FUTURE GRAB BAR INSTALLATIONS 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 WL WL WL G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WL WL WL WL WL WL WL WL WL WL WL WL WL WL ELEL EL EL EL EL EL EL EL EL EL EL EL EL EL EL EL EL WL WL WL G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WL WL WL WL WL WL WL WL WL WL WL WL WL WL EL EL EL EL EL EL WL WLWL SS SSSS G GG EL ELEL THIRD STREET 45.00'45.00'PROPERTY LINEPROPERTY LINE 45.00'45.00' PROPERTY LINEPROPERTY LINE 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 0' - 0 " 40 ' - 0 " 13 ' - 6 " 22' - 6" 5' - 0"12' - 6"27' - 6" 19 ' - 3 " 7' - 6 " FIRE SEPARATION DISTANCE LINE (E) SINGLE-FAMILY DWELLING CONVERSION TO ADU G WM 12 ' - 0 " (E ) C O N C R E T E D R I V E W A Y (E) SEWER LATERAL (E) WATER METER (E) GARDEN 5% 5% 5% 5% 5% 5% 5% 5% 103.8' 3,6 A6 5% 2% 2% 2% 2% 2% 12 5 ' - 0 " 45' - 0" (E) ELECTRICAL METER PANEL TO BE CONVERTED INTO A SUBPANEL 0' - 0" 6' - 0 " 22' - 6" SEWER TIE IN (E) DETACHED GARAGE 2% 3,6 A6 LEGALIZE UNPERMITTED PATIO (E) WATER HEATER WITH ENCLOSURE (E) WOOD FENCE(E) WOOD GATE (E) WOOD FENCE (E) WOOD FENCE (N) OUTDOOR AC UNITS SETBACK 5' - 0" 1014 W THIRD ST., UNIT#1 1012 W THIRD ST., UNIT#1 1014 W THIRD ST., UNIT#2 1012 W THIRD ST., UNIT#2 2%5% 5% 5% 5% 5% 5% 5% 2% 2% 2% 5% (N ) O V E R H E A D E L E C T R I C A L L I N E (N) 400 AMP 4-GANG PANEL W/ 100AMP BREAKER FOR EACH UNIT (E) DRIVEWAY APRON PARKWAY 3,6 A6 ELECTRICAL UNDERGROUND LINE THIRD STREET 45.00'45.00'PROPERTY LINEPROPERTY LINE 45.00'45.00' PROPERTY LINEPROPERTY LINE 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 0' - 0 " 40 ' - 0 " 13 ' - 6 " 22' - 6" 5' - 0"12' - 6"27' - 6" 19 ' - 3 " 1012 & 1014 W THIRD ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING G WM 12 ' - 0 " (E ) C O N C R E T E D R I V E W A Y (E) SEWER LATERAL (E) WATER METER (E) GARDEN 103.8' 12 5 ' - 0 " 45' - 0" (E) ELECTRICAL METER PANEL TO BE CONVERTED INTO A SUBPANEL 0' - 0" 22' - 6" SEWER TIE IN (E) DETACHED GARAGE LEGALIZE UNPERMITTED PATIO (E) WATER HEATER WITH ENCLOSURE (E) WOOD FENCE(E) WOOD GATE (E) WOOD FENCE (E) TEMPORARY SHED (E) WOOD FENCE (E) SHED TO BE REMOVED SETBACK 5' - 0" (E ) O V E R H E A D E L E C T R I C A L L I N E (E) DRIVEWAY APRON PARKWAY G WM MAIN PANEL LOCATION GAS METER WATER METER WATER LINE SEWER LINE SITE LEGEND PROPERTY LINE BUILDING LINE (E) GRASS CONCRETE ROOF HATCH GAS LINE ELECTRICAL LINE FIRE SEPARATION DISTANCE LINE EXISTING TREE SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A2 SITE PLAN 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U N N SCALE: 1/8" = 1'-0"1 PROPOSED SITE PLAN SCALE: 1/8" = 1'-0"2 EXISTING SITE PLAN THE APPLICANT/ PROPERY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND /OR CLEARANCE ON-SITE THAT MAY AFFECT THE PROJECT. NOTE:NOTE: RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 4" / 1 2 " 4" / 1 2 " 4" / 12"4" / 12" 2" / 1 2 " BEDROOM #1BEDROOM #1 LIVING ROOMLIVING ROOM KITCHENKITCHEN BATHBATH PATIOPATIO LIVING ROOMLIVING ROOM KITCHENKITCHEN BEDROOM #1BEDROOM #1 BEDROOM #2BEDROOM #2 BATHBATH PORCHPORCH 1012 W 3RD UNIT #21012 W 3RD UNIT #2 LIVING ROOMLIVING ROOM 1012 W 3RD UNIT #11012 W 3RD UNIT #1 15 ' - 0 " 8' - 3 " 12 ' - 0 " 27 ' - 0 " 19 ' - 3 " 9' - 9 " 9' - 6 " 6' - 9 " 12' - 0"11' - 0"4' - 6" 27' - 6" 12 ' - 0 " 15 ' - 0 " 9' - 9 " 9' - 6 " 6' - 0 " 19 ' - 3 " 5' - 6"11' - 6"10' - 6" 11' - 0"16' - 0" 6' - 6" 27 ' - 0 " 52 ' - 3 " 52 ' - 3 " 27' - 6" 7' - 0 " SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A3 EXISTING HOUSE 2025/02/07 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 EXISTING ROOF PLAN SCALE: 1/4" = 1'-0"2 EXISTING FLOOR PLAN SCALE: 1/4" = 1'-0"3 EXISTING NORTH ELEVATION N N SCALE: 1/4" = 1'-0"4 EXISTING SOUTH ELEVATION SCALE: 1/4" = 1'-0"5 EXISTING WEST ELEVATION SCALE: 1/4" = 1'-0"6 EXISTING EAST ELEVATION 84 SF 4x44' RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N 4X4 2X4 @ 16" O.C. 7' 2" / 12" ASPHALT SHINGLES X EHAB ELIAS 2025/01/21 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 REF REF SDCM SD SDCM SD ATTIC VENT CALCULATIONATTIC VENT CALCULATION AREA VENTILATED 450 SF RATE REQ. VENTS: 150 432 SQ.IN TYPE O'HAGING VENT QTY.AREA PER UNIT 4 120 SQ.IN TOTAL AREA PROVIDED 480 SQ.IN 14"x18" GABLE END VENT 0 110 SQ.IN 0 SQ.IN 24"x12" DORMER VENT 0 100 SQ.IN 0 SQ.IN 2.5" SCREENED 3-HOLE VENTS 0 15 SQ.IN 0 SQ.IN 5.5"x14.5" SOFFIT VENTS 0 65 SQ.IN 0 SQ.IN TOTAL VENTILATION PROVIDED 480 SQ.IN UNIT#1 AREA VENTILATED 450 SF RATE REQ. VENTS: 150 432 SQ.IN TYPE O'HAGING VENT QTY.AREA PER UNIT 4 120 SQ.IN TOTAL AREA PROVIDED 480 SQ.IN 14"x18" GABLE END VENT 0 110 SQ.IN 0 SQ.IN 24"x12" DORMER VENT 0 100 SQ.IN 0 SQ.IN 2.5" SCREENED 3-HOLE VENTS 0 15 SQ.IN 0 SQ.IN 5.5"x14.5" SOFFIT VENTS 0 65 SQ.IN 0 SQ.IN TOTAL VENTILATION PROVIDED 480 SQ.IN UNIT#2 D4 D3 D2 D2 D1 W1 W1 D2 D2 D4 D3 D1 2' - 9 " 6' - 0 " 2' - 9 " W1 W1 12' - 7" 8' - 1 1 " 9' - 1 " 12' - 7" 0612 11 11 0612 15 09 10 15 09 08 07 2' - 0 " 4' - 0 " 0' - 9 " 3' - 2 " 1' - 0 " 2' - 6 " 4' - 0 " 2' - 7 " 3' - 1 " 4' - 0 " 2' - 6 " 2' - 0 " 4' - 0 " 0' - 7 " 3' - 2 " 20 ' - 0 " 20 ' - 0 " 40 ' - 0 " 02 02 01 01 05 13 B-B A6 A-A A6 3' - 9 " 10 13 05 08 (E) WATER HEATER WITH ENCLOSURE 1-HOUR FIRE RATED WALL WATER HEATER 1-HR FIRE RATED WALL 1-HR FIRE RATED WALL 1-HR FIRE RATED WALL 6 A6 6 A6 6 A6 3 A4 4" / 12"4" / 12" NOTE: (E) ROOF TO REMAIN 6 A6 6 A6 6 A6 3' - 0" 3' - 0" 4' - 0 " 4' - 0 " WALL LEGEND/S: EXISTING WALL ADDITIONAL WALL FIRE RATED WALL GYPSUM WALLBOARD, RESILIENT CHANNELS,GYPSUM WALLBOARD, RESILIENT CHANNELS, MINERAL FIBER INSULATION, WOOD STUDSMINERAL FIBER INSULATION, WOOD STUDS RESILIENT CHANNELS 24" O.C. ATTACHED AT RIGHT ANGLES TO ONE SIDE OF 2X4 WOOD STUDS 16" OR 24" O.C. WITH 1 1/4" TYPE "S" DRYWALL SCREWS. ONE LAYER 5/8" PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL TO CHANNELS WITH 1" TYPE "S" DRYWALL SCREWS 12" O.C. END JOINTS BACKBLOCKED WITH RESILIENT CHANNELS. 3" MINERAL FIBER INSULATION, 2.0 OR 2.3 pcf, IN STUD PACE. OPPOSITE SIDE: ONE LAYER 5/8" PROPRIETARY TYPE "X" GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO STUDS WITH 1 1/4" TYPE "W" DRYWALL SCREWS 12" O.C. VERTICAL JOINTS STAGGERED 48" ON OPPOSITE SIDES. SOUND TESTED WITH STUDS 16" O.C. AND OPEN FACE OF MINERAL FIBER INSULATION BLANKETS TOWARD RESILIENT CHANNEL-SIDE OF STUD SPACE. (LOAD BEARING) GA FILE NO. WP 3241GA FILE NO. WP 3241 PROPRIETARYPROPRIETARY THICKNESS:53/8" APPROX. WEIGHT:7 pst FIRE TEST:BASED ON UL R3660-7, 11-12-87; UL R27117-61, 8-18-87; UL R7094, 10-24-90; UL DESIGN U311 SOUND TEST:ESTIMATED 1-HR FIRE1-HR FIRE 50 TO 54 STC SOUND50 TO 54 STC SOUND PROPRIETARY GYPSUM BOARDPROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY:5/8" FIREBLOC TYPE "C" BPB AMERICA INC.:5/8" PROROCTM TYPE C GYPSUM PANELS G-P GYPSUM:5/8" TOUGHROCK R FIREGUARD R C LAFARGE NORTH AMERICA INC.:5/8" FIRECHECK R TYPE C NATIONAL GYPSUM COMPANY:5/8" GOLD BOND R BRAND FIRE-SHIELD CTM GYPSUM WALLBOARD PABCO GYPSUM:5/8" FLAME CURB R SUPER 'C' TEMPLE-INLAND FOREST PRODUCT CORPORATION:5/8" TG-C SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A4 PROPOSED ADU FLOOR & ROOF PLAN 09/04/2024 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U DOOR SCHEDULE Type Mark DOOR TYPE OPERATION WIDTH HEIGHT QTY D1 SOLID SWINGING 3' - 0"6' - 8"2 D2 INTERIOR SWINGING 2' - 6"6' - 8"4 D3 CLOSET SLIDING 5' - 0"6' - 8"2 D4 CLOSET BIFOLD 2' - 6"6' - 8"2 WINDOW SCHEDULE Type Mark QTY TYPE/OPERATION MATERIAL WIDTH HEIGHT HEAD HEIGHT W1 4 SINGLE HUNG VINYL FRAME W/ LOW E-DOUBLE PANE GLASS 4' - 0"5' - 0"6' - 8" N 1. 2. 3. THE ATTIC ACCESS SHALL BE A MINIMUM OF 22" X 30". A THIRTY-INCH MINIMUM CLEAR HEAD ROOM SHALL BEPROVIDED ABOVE THE ATTIC ACCESS. ATTIC ACCESS SHALL BE LOCATED AT A READILY ACCESSIBLE LOCATION MECHANICAL VENTILATION IS NOT LESS THAN 6 AIR CHANGES PER HOUR TYPE. THE POINT OF DISCHARGE OFEXHAUST AIR SHALL BE AT LEAST 3 FEET FROM ANY OPENING INTO THE BUILDING. THE EXHAUST VENT SHALL BEEQUIPPED WITH BACK-DRAFT DAMPER TO COMPLY WITH ENERGY REGULATIONS. PROVIDE OUTDOOR COMBUSTION AIR OPENINGS FOR THE MECHANICAL CLOSET WITH THE 2 PERMANENT OPENINGSMETHOD PER CMC SECTION 701.4.1. ONE OPENING SHALL COMMENCE WITHIN12 INCHES OF THE TOP AND THE OTHERCOMMENCING WITHIN 12 INCHES OF THE BOTTOM OF THE ENCLOSURE VENTILATION NOTES: A. B. C. PROVIDE NO LESS THAN 30% UPPER VENTS. BE INSTALLED ON VERTICAL ATTIC SURFACES AND GABLE ENDS. WHEN INSTALLED IN ENCLOSED RAFTER SPACES A MINIMUM AIR SPACE OF 1" MUST BE PROVIDED AND VENTILATIONBE PROVIDED AT UPPER AND LOWER END OF EVERY RAFTER BARRIER. RADIANT BARRIER INSTALLATION SHALL COMPLY WITH THE FOLLOWING: 1. 2. 3. 4. 5. 6. 7. SAFETY OR TEMPERED GLAZING REQUIRED IN THE FOLLOWING LOCATIONS: GLAZING IN ENCLOSURES FOR OR WALLFACING HOT TUBS, WHIRLPOOLS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60INCHES MEASURED VERTICALLY AVOVE A STANDING OR WALKING SURFACE (CRC R308.4) CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUMBACKERS SHALL USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS INSHOWER AREAS. (R702.4.2 CRC) SHOWERS AND TUB-SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUMSETTING OF THE VALVE TO 120 DEGREES F (CPC 408.3) NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURALSTYLE, BUILDING MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND DESIGN. VENT OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH WITH 1/16" MINIMUM TO 1/4" MAXIMUMOPENINGS. A MINIMUM OF A 1-INCH AIRSPACE MUST BE MAINTAINED BETWEEN THE INSULATION AND THE ROOF SHEATHING ATTHE LOCATIONS OF THE VENTS. [CRC R806] BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE THEBUILDING, AND CONTROLLED BY A HUMIDISTAT CAPABLE OF BEING ADJUSTED BETWEEN THE RELATIVE HUMIDITYRANGE OF 50 TO 80 PERCENT. [CGBC 4.506] WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERSOR TUB WITH SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT. [CRCR307.2] NOTES: SCALE: 1/4" = 1'-0"1 PROPOSED FLOOR PLAN SCALE: 1/4" = 1'-0"2 PROPOSED ROOF PLAN N KEYNOTESKEYNOTES 01 DRYER; A) PROVIDE 4" DIA. SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO OUTSIDE W/ BACK DRAFT DAMPER (36" MIN. AWAY FROM OPENING). ;B) MAX. VENT DUCT LENGTH OF 14'. ;C) DOOR AT LAUNDRY ROOM MUST BE LOUVERED TO ALLOW DRYERS TO HAVE SUFFICIENT MAKE-UP AIR.;D) THE SPECIFICATION WILL BE ON A DEFERRED SUBMITTAL. :E) THE DRYER MOISTURE EXHAUST DUCT TO BE METAL OR MOISTURE RATED PVC WITH A SMOOTH INTERIOR SURFACE W/O SCREWS. 02 MINIMUM SHOWER SIZE 1,024 SQ. IN. WITH NO LESS THAN 30" IN ANY DIRECTION (MUST ENCOMPASS A 30" CIRCLE). SHOWER DOORMIN. 22" WIDE, TEMPERED. WATER CLOSET MUST BE CENTERED IN A 30" CLEAR SPACE AND MUST HAVE A 24" CLEAR IN FRONT. FLOORS AND WALL SHALL BE FINISHED WITH A NONABSORBENT SURFACE, SUCH WALL SURFAVES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. 05 NO DISHWASHING MACHINE SHALL BE DIRECTLY CONNECTED TO A DRAINAGE SYSTEM OR FOOD WASTE DISPOSER WITHOUT THE USE OF AN APPROVED DISHWASHER AIR GAP FITTING ON THE DISCHARGE SIDE OF THE DISHWASHING MACHINE. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD-LEVEL (Fl0 MARKING AT/ ABOVE THE FLOOD LEVEL OF THE SINK OR DRAIN BOARD, WHICHEVER IS HIGHER. CPC SEC.807.3 06 CONTINUOUS REINFORCING BACKING FOR FUTURE GRAB BARS. CRC SECTION R327.1.1 ;A) REINFORCEMENT SHALL BE A MINIMUM OF 2X8 SOLID LUMBER AND SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. ;B) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. EXEMPTION #1: WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR -MOUNTED FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY.; C) INFORMATION AND/ OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE. CHAPTER 4. DIVISION 4.4 CRC SECTION R3271.1.1.; D) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE FRAMING IS PROVIDED.; D) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. EXCEPTION #2. ;E) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/ OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENTS FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. EXCEPTION #3. 07 AIRCONDITIONER OUTDOOR UNIT 08 HPTS-50 2** 50-GAL. JA13 ELECTRIC HEAT PUMP WATER HEATER WITH PRESSURE WATER RELIEF VALVE WITH DRAIN OUTSIDE WATER HEATER. CPC 504.6. SE DETAIL 1 2/AD.1.ELECTRIC WATER HEATER, SPECIFICATIONS PER ENERGY DOCUMENTATION 09 LOCAL EXHAUST VENTILATION HOOD, MIN. 110 CFM 10 REFRIGERATOR SPACE W/ COLD WATER STUB-OUT FOR ICEMAKER (VERIFY SIZE W/ MNFR) 11 30" x 60" TUB/SHOWER W/ CURTAIN ROD, IMPERVIOUS SURROUND ON 3 WALLS +7'-0" (MIN. 72"). 12 LAVATORY SINK [CPC TABLE 422.1] [PENETRATIONS IN WALL LINE (I) SHALL COMPLY WITH CRC R302.4] 13 KITCHEN CABINET LAYOUT BY OWNER/CONTRACTOR 15 KITCHEN SINK W/ GARBAGE DISPOSAL (SEE CALGREEN SHEET FOR MAX FLOW RATE) FIREWALL ASSEMBLY DETAIL NTS 3 RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 6 A6 6 A6 13 ' - 6 " 4' - 6 " 8' - 8 " 0' - 4 " 2' - 4 " 6' - 4 " TOP OF WINDOW (E) ROOF TO REMAIN STUCCO TYP. LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 13 ' - 6 " 4' - 6 " 8' - 8 " 0' - 4 " 4 A6 (E) ROOF TO REMAIN STUCCO TYP. 6 A6 8 AD.2 LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 13 ' - 6 " 0' - 4 " 8' - 8 " 4' - 6 " 6 A5 (E) ROOF TO REMAIN STUCCO TYP. 4 A5 8 AD.2 LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 6 A6 6 A6 (E) ROOF TO REMAIN STUCCO TYP. 13 ' - 6 " 4' - 6 " 8' - 8 " 0' - 4 " TOP OF WINDOW2' - 4 " 6' - 4 " LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. BEDROOMBEDROOM BATHBATH (E) ROOF TO REMAIN RIDGE BEAM STRUCTURAL 4 A6 1 A6 2 A6 6 A6 13 ' - 6 " 4' - 6 " 8' - 8 " 0' - 4 " R-19 INSULATION (TO VERIFY W/ T24) 1/2" GYPSUM BOARD R-30 INSULATION (TO VERIFY W/ T24) R-15 INSULATION (TO VERIFY W/ T24) 8 AD.2 LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. KITCHENKITCHEN BEDROOMBEDROOM BEDROOMBEDROOM KITCHENKITCHEN 6 A6 1 A6 5 A6 SLAB ON GRADE R-19 INSULATION (TO VERIFY W/ T24) 1/2" GYPSUM BOARD R-30 INSULATION (TO VERIFY W/ T24)R-15 INSULATION (TO VERIFY W/ T24) 13 ' - 6 " 4' - 6 " 8' - 8 " 0' - 4 " 6 A6 3 A4 3/ 4 " T Y P . NON-BRG. WALL 1X OVER 2X PLATE 3/ 4 " T Y P . TRUSS WHERE OCCURS PER PLAN SIMPSON "DTC" @ 48" OC MAX. 2X BLK'G. @ 48" O.C. W/ (3) 16d'S @ EA. END JOIST OR TRUSS BOTT. CHORD ROOF RAFTER, SEE STRUCTURAL SHEETS ROOFING 2 LAYERS 30# FELT OVER PLYWOOD SHEATHING 2x BLOCK ROOF FASCIA EXTERIOR FINISH INSULATION 2x CEILING JOIST DBL TOP PLATE 2X WALL STUDS CONTINUOU RIDGE VENT 24 GA. RIDGE FLASHING UNDERLAYMENT W/ 12" MIN. OVERLAP RIDGE BOARD, SEE STRUCTURAL SHEETS ROOF RAFTER, SEE STRUCTURAL SHEETS INSULATION (IF REQUIRED) ASPHALT SHINGLE, LAND MARK, ICC-ES- ESR-1389 & ESR-3537 ROOF UNDERLAYMENT ROOF SHEATHING NOTE: PROVIDE EITHER 1" MINIMUM CLEARANCE BETWEEN INSULATION AND ROOF SHEATHING OR USE INSULATION BAFFLE FOR RAFTER SPACE VENTILATION INTERIOR FINISH 2X WALL STUDS SILL PLATE, PRESSURE TREATED CONC. SLAB 10 ML POLY VAPOR DIFFUSION RETARDER IS EXTENDED UNDER FOOTING 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATE R-15 INSULATION PLYWOOD SHEATHING PER STRUCT. MIN 5/8" CDX EXTERIOR FINISH 26 GAGE WEEP SCREED 2" M I N AT P A V E D 6" M I N 8" M I N FINISH GRADE RAFTER CEILING JOIST 7/8" STUCCO NO EAVE VENTS PERMITTED 7/8" STUCCO INSULATION PER PLAN 2x4 STUD WALL 5/8" TYPE "X" GYPSUM BOARD 5/8" TYPE "X" GYPSUM BOARD INSULATION PER PLAN 2x4 STUD WALL 5/8" TYPE "X" GYPSUM BOARD INTERIORINTERIOR SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A6 ADU ELEVATIONS & SECTION 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U 1. A. B. C. 2. ALL EXTERIOR WALL ASSEMBLIES SHALL INCLUDE: TWO LAYERS OF GRADE D OR 60 MINUTE GRADE D PAPER APPLIED OVER ALL WOOD BASE SHEATHING. (CRC R703.7.3 & R703.2). A MINIMUM 0.019 INCH (NO. 26 GALVANIZED SHEET GAGE) CORROSION-RESISTANT WEEP SCREED. (CRC 703.1.1 & R703.7.2.1) THE SCREED SHALL BE INSTALLED WITH THE WEEP OPENINGS LOCATED A MINIMUM 1 INCH BELOW FOUNDATION PLATE LINE AND 4INCHES ABOVE FINISH GRADE OR 2-INCHES ABOVE PAVED AREAS.(CRC R703.1.1 & R703.7.2.1) -ASPHALT ROOF SHINGLES "WEATHER WATCH" ICE &WATER SHIELD AS 30# FELT PAPER MANUFACTURED BYGAF OR EQUAL. INSTALL AS PER MANUFACTURER'SSPECIFICATIONS 1/2" OSB PLYWOOD SHEATHING ( TOMATCH WITHIN EXISTING ROOF/ MATERIAL % COLOR), TYP.OWENS CORNING ROOFING ASPHALT ESR # 1372.CRRC PRODUCT ID # 0890-0013 EXTERIOR CONSTRUCTION ASSEMBLY PLASTER WEEP SCREED NTS 1RIDGE DETAIL NTS 2EAVE DETAIL NTS 3NON-BEARING WALL DETAIL NTS 4 FIRE-RATED WALL DETAIL SCALE: 1/4" = 1'-0"1 EAST ELEVATION SCALE: 1/4" = 1'-0"2 NORTH ELEVATION SCALE: 1/4" = 1'-0"3 SOUTH ELEVATION SCALE: 1/4" = 1'-0"4 WEST ELEVATION SCALE: 1/4" = 1'-0"5 SECTION B-B SCALE: 1/4" = 1'-0"6 SECTION A-A FIRE-RATED NO EAVE DETAIL NTS 5NTS6 RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 WL WL WL G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WL WL WL WL WL WL WL WL WL WL WL WL WL WL 45.00'45.00'PROPERTY LINEPROPERTY LINE 45.00'45.00' PROPERTY LINEPROPERTY LINE 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 0' - 0 " 40 ' - 0 " 13 ' - 6 " 22' - 6" 5' - 0"12' - 6"27' - 6" 19 ' - 3 " 7' - 6 " FIRE SEPARATION DISTANCE LINE 1012 & 1014 W THIRD ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING CONVERSION TO ADU G WM 12 ' - 0 " (E ) C O N C R E T E D R I V E W A Y (E) SEWER LATERAL (E) WATER METER (E) GARDEN E D B C B 103.8' 12 5 ' - 0 " 45' - 0" 0' - 0" 6' - 0 " 22' - 6" SEWER TIE IN (E) DETACHED GARAGE 2% LEGALIZE UNPERMITTED PATIO (E) WATER HEATER WITH ENCLOSURE (E) WOOD FENCE(E) WOOD GATE (E) WOOD FENCE (E) WOOD FENCE (N) OUTDOOR AC UNITS SETBACK 5' - 0" 1014 W THIRD ST., UNIT#1 1012 W THIRD ST., UNIT#1 1014 W THIRD ST., UNIT#2 1012 W THIRD ST., UNIT#2 2%5% 5% 5% 5% 5% 5% 5% 2% 2% 2% 5% (E) DRIVEWAY APRON PARKWAY 3,6 A6 ELECTRICAL UNDERGROUND LINE SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A7 EROSION & SEDIMENT CONTROL PLAN 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. EROSION CONTROL IS REQUIRED FOR GRADING OPERATIONS DURING THE RAINY SEASON FROMOCTOBER 15TH TO APRIL 15TH. APPROVED PLANS ARE REQUIRED FOR ALL ROUGH GRADING. IN CASE OF EMERGENCY, CALL: ORCHID L & HAN NGUYENT AT (714) 417 32023. THE DESIGN CIVIL ENGINEER WILL SUPERVISE EROSOIN CONTROL WORK AND ENSURE THAT WORK IS IN ACCORDANCE WITH THE APPROVED PLANS (IF REQUIRED). EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON.NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE ANDSTOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARYDEVICES WHEN RAIN IS IMMINENT. DEVICES SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE CITY ENGINEER. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE 5.DAYS RAIN PROBABILITY FORECAST EXCEEDS 40%. AFTER A RAINSTORM, ALL SILT AND DEBRIS SHALL BE REMOVED FROM CHECK GRADED AREAS AROUND THE TRACK PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATER CREATES A HAZARDOUSCONDITION. DESILTING BASINS ARE TO BE CONSTRUCTED AS GRADING OF INDIVIDUAL GRADING AREAS ARECOMPLETE PER ROUGH GRADING PLANS. THE CITY ENGINEER RESERVES THE RIGHT TO MAKE CHANGES OR MODIFICATIONS TO THIS PLANAS DEEMED NECESSARY. INFORMATION IN THIS PLAN IS FOR EROSION CONTROL ONLY.ALL OTHER INFORMATION ISSUBJECT TO CHANGE. TEMPORARY EROSION PROTECTION IS REQUIRED FOR MANUFACTURED SLOPES PRIOR TOPERMANENT PLANTING. AREAS SHALL BE MAINTAINED IN SUCH A STATE THAT FIRE ACCESS SHALL SEE MAINTAINED ATALL TIMES (INCLUDING ACCESS TO NEIGHBORING PROPERTIES). NO OBSTRUCTION OR DISTURBANCE OF NATURAL DRAINAGE COURSES OR EXISTING STORMDRAIN INLETS SHALL OCCUR DURING THE RAINY SEASONS, UNLESS ADEQUATETEMPORARY/PERMANENT DRAINAGE FACILITIES HAVE BEEN APPROVED AND INSTALLED TOCARRY SURFACE WATER TO THE NEAREST PRACTICAL STREET, STORM DRAIN OR NATURALWATER COURSE. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS IN SUCH A MANNER THAT STORM RUNOFF WILL BECONTAINED WITHIN THE PROJECT OR CHANNELS INTO THE STORM DRAIN SYSTEM WHICH SERVES THE RUNOFF AREA.STORM RUNOFF FROM ONE ARE SHALL NOT BE ALLOWED TO DIVERT TO ANOTHER RUNOFF AREA. CONFORMANCE WITH THE REQUIREMENT OF THESE PLANS SHALL IN NO WAY RELIEVE THE CONTRACTOR FROMHIS RESPONSIBILITIES TO THIS SITE AND ADJACENT PROPERTIES. TEMPORARY EROSION CONTROL SHALL CONSIST OF,BUT NO TO BE LIMITED TO, CONSTRUCTING SUCH FACILITIES AND TAKING SUCH MEASURES AS ARE NECESSARY TOPREVENT, CONTROL AND ABATE WATER, MUD AND EROSION DAMAGE TO PUBLIC AND PRIVATE PROPERTY AS ARESULT OF THE CONSTRUCTION OF THIS PROJECT. SLOPES CONSTRUCTED PRIOR TO OCTOBER 1 SHALL BE TREATED FOR EROSION CONTROL PRIOR TO OCTOBER15. SLOPES CONSTRUCTED AFTER OCTOBER 1 SHALL BE TREATED FOR EROSION CONTROL AS THE CONSTRUCTION OFSLOPE PROGRESS IN INCREMENT OF 25 FEET OR LESS MEASURES VERTICALLY. FILL AREAS WHILE BROUGHT UP TO GRADE AND DURING PERIODS OF COMPLETION PRIOR TO FINAL GRADE,SHALL BE PROTECTED BY VARIOUS MEASURES TO ELIMINATE EROSION AND THE SILTATION OF DOWNSTREAMFACILITIES AND ADJACENT AREAS. THESE MEASURES MAY INCLUDE, BUT SHALL NOT BE LIMITED TO: TEMPORARYDOWNDRAINS, EITHER IN THE FORM OF PIPES OR PAVED DITCHES WITH PROTECTED OUTFALL AREAS; GRADED BERMSAROUND AREAS TO ELIMINATE EROSION OF FILL SLOPES BY SURFACE RUNOFF, CONFINED PONDING AREAS TO DESILTRUNOFF; TEMPORARY CHECK DAMS IN TOE OF SLOPE DITCHES TO DESILT RUNOFF; PROTECTION SUCH AS SANDBAGS AROUND INLETS WHICH HAVE NOT BEEN BROUGHT UP TO GRADE, AND EARTH BERMS AND APPROPRIATEGRADING TO DIRECT DRAINAGE AWAY FROM THE EDGE OF THE SLOPES SHALL BE CONSTRUCTED AND MAINTAINED ONTHOSE FILL AREAS WHERE EARTH-WORK OPERATIONS ARE NOT IN PROGRESS. TOP OF CUT BROW DITCHES, WHERE REQUIRED ON THE PLANS, SHALL BE CONSTRUCTED PRIOR TO EXCEEDING12 FEET OF CUT MEASURED VERTICALLY. CLEARING AND GRUBBING SHOULD BE LIMITED TO AREAS THAT WILL RECEIVE IMMEDIATE GRADING. EROSION CONTROL MEASURES WILL BE REQUIRED TO PROTECT AREAS THAT HAVE BEEN CLEARED AND GRUBBED PRIOR TOGRADING OPERATION, AND THAT ARE SUBJECT TO RUNOFF DURING THE PERIOD FROM THE BEGINNING OF THE RAINYSEASON. THESE MEASURES MAY INCLUDE BUT SHALL NOT BE LIMITED TO: GRADED DITCHES; BRUSH BARRIERSAND SILT FENCES. CARE SHALL BE EXERCISED TO PRESERVE VEGETATION BEYOND THE LIMITS OF GRADING. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE CORRECTIONOF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST, THE REQUIRED PLAN REVISIONSSHALL BE PROMPTLY TO THE CITY ENGINEER FOR APPROVAL. EROSION CONTROL GENERAL NOTES: SCALE: 1/8" = 1'-0"1 EROSION & SEDIMENT CONTROL PLAN RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 WL WL WL G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WL WL WL WL WL WL WL WL WL WL WL WL WL WL WL WL WL G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WL WL WL WL WL WL WL WL WL WL WL WL WL WL THIRD STREET 45.00'45.00'PROPERTY LINEPROPERTY LINE 45.00'45.00' PROPERTY LINEPROPERTY LINE 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 0' - 0 " 40 ' - 0 " 13 ' - 6 " 22' - 6" 5' - 0"12' - 6"27' - 6" 19 ' - 3 " 7' - 6 " FIRE SEPARATION DISTANCE LINE 1012 & 1014 W THIRD ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING CONVERSION TO ADU G WM (E ) C O N C R E T E D R I V E W A Y (E) SEWER LATERAL (E) WATER METER (E) GARDEN 103.4' 103.8' 104.0' 103.9' 104.3' 103.5' 104.0' 12 5 ' - 0 " 45' - 0" 0' - 0" 6' - 0 " 22' - 6" SEWER TIE IN (E) DETACHED GARAGE LEGALIZE UNPERMITTED PATIO (E) WOOD FENCE(E) WOOD GATE (E) WOOD FENCE (E) TEMPORARY SHED (E) WOOD FENCE SETBACK 5' - 0" 1014 W THIRD ST., UNIT#1 1012 W THIRD ST., UNIT#1 1014 W THIRD ST., UNIT#2 1012 W THIRD ST., UNIT#2 (E) DRIVEWAY APRON PARKWAY 3,6 A6 THIRD STREET 45.00'45.00'PROPERTY LINEPROPERTY LINE 45.00'45.00' PROPERTY LINEPROPERTY LINE 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 12 5 . 0 0 ' 1 2 5 . 0 0 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 12 5 . 0 0 ' 1 2 5 . 0 0 ' 0' - 0 " 40 ' - 0 " 13 ' - 6 " 22' - 6" 5' - 0"12' - 6"27' - 6" 19 ' - 3 " 7' - 6 " FIRE SEPARATION DISTANCE LINE 1012 & 1014 W THIRD ST., SANTA ANA, CA (E) SINGLE-FAMILY DWELLING CONVERSION TO ADU G WM (E ) C O N C R E T E D R I V E W A Y (E) SEWER LATERAL (E) WATER METER (E) GARDEN 5% 5% 5% 5% 5% 5% 5% 5% 5% 103.8' 3,6 A6 2% 5% 2% 2% 2% 2% 2% 12 5 ' - 0 " 45' - 0" 0' - 0" 6' - 0 " 22' - 6" SEWER TIE IN (E) DETACHED GARAGE 2% 3,6 A6 LEGALIZE UNPERMITTED PATIO (E) WOOD FENCE(E) WOOD GATE (E) WOOD FENCE (E) WOOD FENCE (N) OUTDOOR AC UNITS SETBACK 5' - 0" 1014 W THIRD ST., UNIT#1 1012 W THIRD ST., UNIT#1 1014 W THIRD ST., UNIT#2 1012 W THIRD ST., UNIT#2 2%5% 5% 5% 5% 5% 5% 5% 2% 2% 2% 5% (E) DRIVEWAY APRON PARKWAY 3,6 A6 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A8 EXISTING & PROPOSED CONTOUR MAP 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U SCALE: 1/8" = 1'-0"1 EXISTING CONTOUR MAP SCALE: 1/8" = 1'-0"2 PROPOSED CONTOUR MAP RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A9 SINGLE FAMILY RESIDENTIAL MANDATORY REQUIREMENTS 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SOLID BACKING HEADER ROUGH OPENING JAMB SILL SILL FLASHING HEADER JAMB SILL ROUGH OPENING 2" CONTINUOUS BEAD OF SEALANT UNDER NAILING FLANGE. HEAD FLASHING WINDOW FRAMING OR SIMILAR OPENING LINE OF NAILING FLANGE BUILDING PAPER TYP. WINDOW FRAME OR SIMILAR OPENING CUT AWAY EXCESS BLDG. PAPER AT OPENING 4" M I N . BUILDING PAPER UNDER SILL STRIP STEP 4: STEP 3: STEP 2: STEP 1: · ATTACH SILL STRIP OF 9" WIDE VYCOR V40 WEATHER BARRIER STRIP WITH TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. · PROVIDE SOLID BACKING AT ALL AREAS WHERE FLASHING MATERIAL LAPPING WILL OCCUR. · EXTEND THIS STRIP AT LEAST 11" BEYOND THE EDGE OF THE ROUGH OPENING. · ATTACH FLASHING MATERIAL WITH GALVANIZED ROOFING NAILS OR CORROSION- RESISTANT STAPLES. · ATTACH JAMB STRIPS OF 9" WIDE MOISTOP FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB OF THE ROUGH OPENING. · START JAMB STRIPS 2" BELOW SILL STRIP AND EXTEND 4" ABOVE LOWER EDGE OF HEADER. · APPLY A CONTINUOUS BEAD OF SEALANT TO THE BACK OF THE FRAME NAILING FLANGE · PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE INSTALLED JAMB AND SILL MOISTOP FLASHING MATERIAL. · APPLY AN ADDITIONAL LAYER OF 9" WIDE VICOR V40 WEATHER OVER THE JAMB NAILING FLANGE. · ATTACH 9" WIDE VYCOR V40 WEATHER BARRIER STRIP OVER THE HEAD FLANGE. EXTEND THIS STRIP 2" BEYOND THE OUTER EDGE OF THE JAMB FLASHING MATERIAL. -STARTING FROM THE BASE OF THE WALL, APPLY BUILDING PAPER UNDER THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. -APPLY THE NEXT COURSE OF BUILDING PAPER (BUTTING TO THE FRAME OPENING) OVER THE JAMB FLASHING MATERIAL. -APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF 6". 1.SECTION 1402 OF THE 2019 EDITION OF THE U.B.C. STATES "EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN A MANNER AS TO MAKE THEM WEATHERPROOF." THE PROCEDURE ABOVE IS RECOMMENDED TO ACHIEVE THIS INTENT FOR THE FLASHING OF WALL OPENINGS TO INCLUDE BUT NOT LIMITED TO: WINDOWS, DOORS, VENTS, ETC. 2.ALL MATERIALS SHALL BE IN STRICT CONFORMANCE WITH U.B.C. STANDARD 14-1 3.APPLICATION OF FINISH MATERIALS OVER FLASHING MATERIALS SHOWN SHALL BE AS SPECIFIED BY CODE REQUIREMENTS, MANUFACTURER'S INSTRUCTIONS AND THE BEST PRACTICES OF THE TRADE. 4.ADDITIONAL MATERIALS, ie. METAL HEAD FLASHING, ELASTOMERIC SHEET WATERPROOFING ETC. MAY OCCUR, DEPENDING ON THE SPECIFIC FINISH MATERIALS BEING USED. REFER TO INDIVIDUAL DETAILS FOR ADDITIONAL INFORMATION. NOTES: 4" 4" 4" 4" 4" 3" 4" 4" 4" 4"G.S.M. 3/ 8 " G.S.M. FLASHING FLANGE SOLDER ALL SEAMS SLOPE TOP 1/8" PER/ 12" G.S.M. FLASHING COLLAR, SEE SPECIFIC APPLICATION DETAIL FOR FURTHER INFO. FLASHING FIN AT WOOD MEMBERS, SEE SPECIFIC APPLICATION DETAIL RECTANGULARRECTANGULAR DRIP / INTERLOCKDRIP / INTERLOCK G.S.M. FLASHING FLANGE SOLDER ALL SEAMS G.S.M. FLASHING COLLAR, SEE SPECIFIC APPLICATION DETAIL FOR FURTHER INFO. ROUNDROUND SEE PLANS FOR SPECIFIC PENETRATION SIZE 26 GA 1-PIECE GSM PAN FLASHING SOLDIER ALL JOINTS ISOMETRIC (PARTIAL) WEATHERSHIP BASE ADJUSTABLE ALUM. CLAD THRESHOLD ONE-PIECE SOLDIERED SHEET MTL. PAN FLASHING 2x PTDF SLEEPER (ATTACH PER S.D.) 1x2 CEDAR TRIM SEE 1/AD. 1 FOR ADDITIONAL FLASHING INFO. HARDSCAPE SLAB SLOPE4" U O N BUILDING SLAB 3/ 8 " - 3 / 4 " FINISH FLR. DR. FRAME BEYOND DOOR 6" 4" V.I.F. 2" M I N . 1/ 2 " PRESSURE RELIEF VALVE/ DRAIN ENDS OUTSIDE =6" FROM GRD. SOLID BLOCKING. 5/8" GYPSUM BOARD1/4" x 3" MIN. LAG SCREW INTO LEDGER W/ 2x4 WOOD LEDGER WASHER 3/4"x24 GAUGE PERFORATED STEEL PLUMBERS TAPE MIN. 1" 6" MIN . HOT COLD T&P VALVE2x4 WOOD LEDGER OVERFLOW WATERTIGHT PAN W/ 1" DRAIN TO PREVENT LEAKAGE FU L L H E I G H T SEISMIC BRACE SEISMIC BRACE WATER HEATER 4 " UP P E R 1 / 3 LO W E R 1 / 3 18 " MI N . PLATFORM. MUST SUPPORT WATER HEATER ON ITS OWN FEET FINISH FLOOR GAS MIN. CLR. PROVIDE 2 STRAPS THE UPPER 1/3 AND LOWER 1/3 OF THE WATER HEATER OVERALL HEIGHT. PER CPC 510.5 GYPSUM BOARD, 1" MIN. THK. 1/4"X5" MIN. LAG SCREW INTO STUDS W/ WASHER. 4" ELASTOMERIC SHEET WATERPROOFING EXTEND AS NOTED SLOPE METAL FLASHING WITH DRIP EXTEND 4" MIN ABOVE CEDAR WOOD TRIM PER ELEVATION WINDOW FRAME WINDOW FRAME SEALANT WOOD TRIM PER ELEVATION ELASTOMERIC SHEET WATERPROOFING EXTEND AS NOTED DBL 2x SILL 2x BLOCKING OMIT AT PLYWD. SHEARWALL GYP. BD. GYP. BD. HEADER PER PLAN HEAD SILL 0' - 6 " WALL SHEATHING PER PLAN, TYP. 2X4 DF#2 @ 16 TYP. OC 2X SILL DF#2 P.T.D.F. SILL PLATE W/ ANCHOR BOLTS PER AB SCHEDULE S.S.D. ONE POUR 12" MAT SLAB S.S.D. NATURAL UNDISTURBED GRADE #4 @ 18" O.C.E.W. S.S.D. HORIZONTAL SIDING WOOD OVER WATER-RESISTIVE BARRIER INSTALLED PER [R703.5.3] WOOD SIDING OPTIONWOOD SIDING OPTION EXTERIOR PLASTER (STUCCO) OVER CORROSION-RESISTANT LATH OVER (2) LAYERS OF WATER- RESISTIVE BARRIER INSTALLED PER [R703.7] STUCCO OPTIONSTUCCO OPTION CORROSION RESISTANT WEEP SCREED [R703.7.2.1] 2X PRESSURE TREATED SILL PLATE0' - 8 " 1' - 0 " WARM AIR FURNACES INSTALLED IN ATTICS OR FURRED SPACES SHALL BE INSTALLED AS PER UMC 307.3 AND SHALL INCLUDE THE FOLLOWING: 1. A MINIMUM 30"X30" ACCESS (20 FEET MAXIMUM FROM FURNACE) 2.CONTINUOUS SOLID FLOORING (5/8" CDX OR EQ.) 24" MIN. WIDE FROM ACCESS TO FURNACE 3.A LEVEL WORKING PLATFORM 30" MIN. IN DEPTH ALONG THE ENTIRE FIREBOX SIDE OF FURNACE 4. A PERMANENT 110V ELECTRICAL OUTLET AND LIGHTING FIXTURE LOCATED AT OR NEAR FURNACE LIGHTING FIXTURE TO BE CONTROLLED BY A SWITCH LOCATED AT ACCESS. 5.THE FAU SHALL BE LISTED FOR INSTALLATION IN ATTICS AND ON COMBUSTIBLE FLOORING. CLEARANCES SHALL BE AS PER MANUFACTURER'S SPECIFICATIONS AND PER UBC 304. 22" M I N 30" M I N 30" 24" 24" 4 1 2 4 3 5 NOTE: TRUSS DESIGN BY TRUSS MFR. SEE DET. 12/ADI FOR ADDITIONAL INFO. NOTE: VERIFY LENGTH OF PLATFORM W/ HVAC CONTRACTOR SEE DETAIL 12/AD I FOR ADDITIONAL REQUIREMENTS PER UMC 319 1.FRAMING SPAN O/ MIN. 3 TRUSSES, S.S.D. 2.3/4" PLYWD. 3.3/8" GYPSUM BD. AT CEILING F.A.U. 30" X 30" CLR. ACCESS AREA FAU CONTROLS 5'-0" MIN. SEE PLAN 10" CLR. MIN. 3 1 2 PROVIDE POSITIVE ELECTRICAL DISCONNECT (SEE SECT. NEC 503) LIGHT OVER CONTROLS (SECT. 309 ASO REQUIRES CONVENIENCE OUTLET (RECEPTACLE) WITHIN 25' OF EQUIP..) 24" WIDE SOLID FLOORING ACCESS WAY RELATED CODES SECTIONS: UMC 307.3 CENTRAL WARM AIR FURNACES INSTALLED IN THE ATTIC MUST BE ACCESSIBLE FOR ROUTINE INSPECTION AND MAINTENANCE BY THE OWNER, OCCUPANT AND FOR SERVICE AND REPAIR AS NEEDED. CHANGING FILTERS, LUBRICATING MOTOR AND FAN BEARINGS, CHECKING BELT TENSIONS AND RELIGHTING THE PILOT FOLLOWING A SERFICE INTERRUPTION ARE NORMAL OWNER FUNCTIONS. ADEQUATE LIGHT, AND ELECTRICAL OUTLET, SAFE ACCESS WAY AND SUFFICIENT WORKING SPACE ON THE CONTROL SIDE ALL ENCOURAGE AND FACILITATE MAINTENANCE AND ENABLE RAPID EGRESS IN AN EMERGENCY. ACCESS OPENING MIN. 22"X30" OR DIMENSION OF APPLIANCE LIGHT SWITCH 20'-0" MAX. WARM AIR FURNACE WORKING SPACE AT CONTROLS MAX 20'-0" -- MI N . C L R . 30 " - MIN . 0' - 6 " 2' - 6" HOUSE-R3 1/2" GYPCO. BD. AT INTERIOR OF HOUSE 2X4 (MIN) STUDS AT 16" O.C. (FIRE WALL) 5/8" TYPE "X" GYP. BD. O/ 2X4 FRAME (FRAME PANEL ON FOUR SIDES) 5/8" TYPE "X" GYP.BD. O/ INT. OF GARAGE, TYP. ELECTRIC SUB- PANEL GARAGE - UI AT GARAGE WALL HOUSE - R35/8" TYPE "X" GYP. BD. AT 1-HOUR OCC. SEP. WALL, W.O. 2X4 (MIN.) STUBS AT 16" O.C. (FIRE WALL) 1/2" GYP. BD. O/ 2X4 FLAT FRAME WALL (FRAME PANEL ON FOUR SIDES) ELECTRIC SUB-PANEL HOUSE - R3 AT INTERIOR WALL ELECTRICAL SUB-PANEL ELEVATION 1' - 0 " 2' - 6 " 5' - 4 " ( N T S ) 3 ' - 7 " - CE I L I N G H T . P E R P L A N - TO.S. SCALE:NTS1FLASHING AT OPENINGS SCALE:NTS2TYPICAL PENETRATION FLASHING SCALE:NTS3INSWINGING DOOR SILL AT SLAB SCALE:NTS4WATER HEATER SEISMIC BRACE SCALE: 1" = 1'-0"6 TYPICAL HEAD & SILL DETAIL SCALE: 1" = 1'-0"7 EXTERIOR WALL FOOTING SCALE:NTS9ACCESS FURNACE AT ATTIC SCALE:NTS10FAU PLATFORM SCALE:NTS8FURNACE AT ATTIC SCALE:NTS5ELECTRICAL SUB-PANEL SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 AD.1 ARCHITECTURAL DETAILS 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 PLYWOOD SHEATHING, SSD LAP UNDERLAYMENT MIN. 6" AT RIDGE W/ I CONT. PIECE OF UNDERLAYMENT AT RIDGE S-TILE ROOF TRUSSES, SSD STUD WALL OPERABLE WINDOW EXTERIOR WALL CEILING NOT MORE THAN 44" ABOVE FLOOR ON THE FINISHED SILL HEIGHT 24 " M I N . C L E A R OP E N I N G H E I G H T FLOOR 20" CIR. MINIMUM PLAN VIEW SECTION VIEW 5/8" GYPSUM BOARD WOOD HEADER - SEE STRUCTURAL WOOD CASING, BY OTHERS DOOR, BY OTHERS WOOD DOOR FRAME SHIM, AS REQUIRED 5/8" TYPE "X" GYPSUM BOARD 5/8" GYPSUM BOARD (2) 2X4 WOOD JAMBS WOOD CASING, BY OTHERS DOOR, BY OTHERS WOOD DOOR FRAME SHIM, AS REQUIRED GYP. BD RADIUS CORNER - USE PLASTIC CORNERS AT WET AREAS GYP. BD SEE PLAN FOR FRAMING 2S/1P 1S/2P SHELF POLE SE E P L A N 3' - 0 " 3' - 0 " SE E P L A N 1' - 0 " 0' - 3 " 5' - 6 " 2X4 P.T. CURB ANCHORED TO SLAB 3/8" ANCHOR BOLTS AT 12" O.C., 6" AT ENDS MORTAR BED-SET CERAMIC TILE SLOPE TILE TO DRAIN AT 1/4" PER FOOT HOT MOP SLOPE TO DRAIN AT 1/4" PER FOOT (E) CONCRETE SLAB METAL FLASHING RETURN UP WALL 4" BEHIND WEATHER BARRIER CLASS A TILE ROOF DRIP EDGE TRELLIS FRAMING PER STRUCTURAL SCALE: 1" = 1'-0"6 TYPICAL AT RIDGE SCALE:NTS4EMERGENCY EGRESS DETAIL SCALE: 3" = 1'-0"2 TYP. WOOD FRAME INTERIOR DOOR HEAD SCALE: 3" = 1'-0"3 TYP. WOOD FRAME INTERIOR DOOR JAMB SCALE: 3" = 1'-0"5 ROUND GYPSUM BOARD CORNER SCALE: 1/2" = 1'-0"7 CLOSET SHELVING SCALE: 3" = 1'-0"1 CURB AT SHOWER ENTRY SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 AD.2 ARCHITECTURAL DETAILS 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U SCALE: 1/8" = 1'-0"8 PORCH AWNING TO WALL CONNECTION RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 2 4' - 0 " 4x4 4x4 5/ 8 " A B @3 2 " O . C 2 4' - 0 " 4x4 4x4 5/ 8 " A B @3 2 " O . C 2 4' - 0 " 4x4HDU4 4x4 5/ 8 " A B @3 2 " O . C 2 4'-0" 4x 4 4x 4 5/8" AB @32" O.C 2 8'-0" 4x 4 HD U 4 4x 4 5/8" AB @32" O.C 4x 4 4x 4 5/8" AB @32" O.C 2 8'-0" 4x 4 4x 4 HD U 4 5/8" AB @32" O.C 2 4'-0" 2 4' - 0 " 4x4 5/ 8 " A B @3 2 " O . C 4x4 12 SD1 TYP. 12 SD1 TYP. 2 "3" CONC. SLAB OVER 10-MIL VISQUEEN MOISTURE BARRIAR 4x4HDU4 5/ 8 " A B @3 2 " O . C 4x4 2 2' - 0 " 4x4 5/ 8 " A B @3 2 " O . C 4x4 2 2' - 0 " 19 SD13 19 SD13 19 SD13 2 SD1 2 "3" CONC. SLAB OVER 10-MIL VISQUEEN MOISTURE BARRIAR 2 SD1 3 SD1 HDU4 HDU4 HDU4 HDU4 HDU4 HD U 4 HD U 4 HD U 4 HDU4 HDU4 HDU4 HDU4 HDU4 HD U 4 HD U 4 HD U 4 3 SD1 3 SD1 3 SD1 3 SD1 21 SD1 21 SD1 21 SD1 3 SD1 11 SD1 11 SD1 11 SD1 11 SD1 3 SD1 LEGENDS : DETAIL SHEAR WALL NAME SHEAR WALL LENGTH NEW FOOTING EXISTING FOOTING X L=X X-X X SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 S-1 FOUNDATION PLAN 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 PROPOSED FOUNDATION PLAN FOUNDATION PLAN NOTES: (N) CONTINUOUS FOOTING 12" WIDTH X 18" DEEP W/(2) #5 REBAR AT TOP AND (2)#5 BOTTOM. (N) 3" CON. 3,000 PSI @ 28 DAYS W/ #3 @16" O.C. E.A. WAY OVER 10MIL VISQUEEN OVER EX. GARAGE SLAB DRILLED INTO (E) FOUNDATION AND FILLED WITH SIMPSONS "SET-XP" EPOXY. NEW 12"X12"X12" DEEP PAD FOOTING W/#4 REBAR @6" O.C. MAX. EA WAY AT BOTTOM 1 2 3 ANCHOR BOLT NOTES: (N) FOOTING: 5/8 X 12" LONG BOLTS @ 48" (U.N.O.) NOTES: -IF MISSING ANCHOR BOLTS THEN DRILL 3/4" X 6" DEEP W/5/8: (RFB#5X10) @32" O.C. WITH SET- XP EPOXY (SPECIAL INSPECTION IS REQUIRED) -SCARIFY TOP 12" OR RE-COMPACT 4" PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATION INSPECTION. PRE-SATURATION SUBGRADE TO 110% OF OPTIMUM MOISTURE CONTENT IS REQUIRED, CODE REQUIREMENT: • • • • • • • THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) 2022 CALIFORNIA BUILDING CODE (CBC) FOUNDATION NOTES: 1. A. B. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. FOUNDATION HAS BEEN DESIGNED ASSUMING MIN. ALLOWABLE SOIL BEARING PRESSURE. (SEC. 1802.6) SHALL BE AS FOLLOWS: CONTINUOUS FOOTING : 1500 SF ISOLATED FOOTING: 1500 SF CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH (fC) OF 3,000 psi ALL FOOTING SHALL BE POURED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE U.N.O. ALL FOOTING SHALL BE CENTERED ON WALLS AND COLUMNS, U.N.O. ALL EXISTING FILL SOIL AND DISTRUBED NATURAL SOILS ARE TO BE EXCAVATED AND REPLACED WITH PROPERLY COMPACTED FILL. ALL FILLING, BACKFILLING, RECONNECTION, ETC. IS TO BE ACCOMPLISHED ONLY UNDER THE SUPERVISION OF A SOIL ENGINEER, COMPACTED FILL SHALL BE 95% DENSITY PROVIDE MIN. 5/8" X 12" ANCHOR BOLTS WITH 3"X3"X1/4" WASHERS, EMBEDDED 7" MIN. INTO CONCRETE OR MASONRY AND SPACE MAX. 48" O.C. PROVIDE MIN. 2 BOLTS PER PLATE AND NOT MORE THAN 12" OR LESS THAN 4" OR PLATE END AND CORNER. (CHAPTER 4 CRC) FASTENERS FOR PRESERVATIVE-TREATED SHALL BE HOT DIPPED ZINC-COATED GLAVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER IN ACCORDANCE WITH ASTM A 153(R317.3) FOUNDATION SILL PLATE SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NTOCHES AND DRILLED HOLES OR PRESERVATIVE TREATED WOOD SHALL BE FIELD-REATED PER AWPA M4.(R317.1.1). ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL BE REMOVED AND RELOCATED THE CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, AND PROTECTION OF ANY ACCORDANCE WITH ALL NATIONAL STATED AND LOCAL SAFETY ORDINANCE READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING OFFICIAL PRIOR TO THE PLACING OF ANY CONCRETE MINIMUM SLAB REINFORCEMENT AND PAD REQUIREMENTS SHALL CONFORM TO THE SOILS ENGINEER'S RECOPMMENDATIONS UNLESS NOTED OTHERWISE PROVIDE A MIN. 26-GAGE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM O F6" ABOVE EARTH OR 4" ABOVE PACED AREA. (R703.6.2.1) WOOD SILL PLATE SHALL BE MINIMUM 8" ABOVE ADJACENT GRADE (R317.1) STRUCTURAL DESIGN DATA: VERTICAL LOADS: DEAD(DL) LIVE(LL) ROOF LOAD:15 PSF 20 PSF CEILING LOAD:10 PSF 10 PSF (UNINHABITABLE ATTIC WITHOUT STORAGE) EXT. WALL LOAD:17 PSF INT. WALL LOAD:7 PSF WIND DESIGN DATA: BASIC WIND SPEED:95 MPH WIND EXPOSURE:C EARTHQUAKE DESIGN DATA: IMPORTANCE FACTORE:1 =1.0 MAPPED Ss = 1.835 AND Si = 0.653 F =1.2 S =1.468 SITE CLASS: D - DEFAULT SEISMIC DESIGN CATEGORY: D BASIC SEISMIC-FORCE-RESISTING SYSTEM = LIGHT-FRAMED WOOD SHEATHED SHEAR WALLS RESPONSE MODIFICATION FACTOR, R = 6.5 SEISMIC RESPONSE COEFFICIENT, Cs = 0.226 ANALYSIS PROCEDURE USED:EQUIVALENT LATERAL FORCE SOIL DATA: ASSUME ALLOWABLE SOIL BEARING 1,500 PSI e a DS RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 A6 1 4X6 HEADER 4X6 HEADER 4X 6 H E A D E R 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER 4X 6 H E A D E R 4X 6 H E A D E R 2 4' - 0 " 2 4' - 0 " 2 4'-0" 2 8'-0" 2 8'-0" 2 4'-0" 2 4' - 0 " 2 2' - 0 " 2 2' - 0 " 4X6 HEADER (E) 2X6 RR @16" OC(E) 2X6 RR @16" OC (E) 2X6 RR @16" OC(E) 2X6 RR @16" OC (E) 2X6 RR @16" OC(E) 2X6 RR @16" OC (E) 2X6 RR @16" OC(E) 2X6 RR @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N) 2X6 CJ @16" OC (N ) 6 X 8 B E A M (N ) 6 X 8 B E A M 4 SD1 9,11 SD1 18 SD1 6 SD1 (N ) 6 X 8 B E A M (N ) 6 X 8 B E A M 20 SD1 20 SD1 4 SD1 4 SD1 2x 1 0 R I D G E 8 SD1 8 SD1 8 SD1 (N) 4X6 POST (N) 4X6 POST (N) 4X6 POST (N) 4X6 POST RR RR RR RR RR RR (N) 2X6 RR, SISTER W/ (E) RR @16" OC AT (N) TRELLIS OVER FRONT ENTRY (N) 2X6 RR, SISTER W/ (E) RR @16" OC AT (N) TRELLIS OVER FRONT ENTRY SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 S-2 FRAMING PLAN (ADU) 2025/02/06 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 PROPOSED FRAMING PLAN RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 DOUBLE TOP PLATED SIMPSO N STRAP LSTA24 SIMPSON PER PLAN HEADER OR BEAM PER PLANS POST/KP PER PLANS SIMPSON STRAP LSTA24 KING POST PER PLAN HEADER PER PLAN SIMP. A35 BEAM PER PLAN BEAM PER PLANS SIMPSON A35 DOUBLE TOP PLATE SIMP. A35 SLOPE CUT WHERE OCCURS 1/2" OSB ROOF SHEATHING 2x ROOF RAFTER STUD WALL TOP PLATE 2x FASCIA SHIP LAP 2x BLOCKING E.N. 8-16d NAILS C.J TO R.R CEILING JOIST PER PLAN A35 @16" OC U.N.O. CEILING JOIST PARALLEL TO ROOF JOIST SHEAR WALL WHERE OCCURS CONTINUOUS TOP PLATE HEADER PER PLAN SIMP. ST 18 ONE SIDE POST PER PLAN 2x4 COLLAR TIE @32"O.C. 3-10d NAILS 1. 2x4 STUDS @ 16"O.C. 2. 2X P.T.D.F. PLATE WITH 0.18"DIA. x 3" SHOT PINS @32" O.C. WITH 14GA GAGE WASHERS & FIRST 2 PINS PLACED 6" & 10" FROM PLATE ENDS ICC# ESR-1799 (RAMSET) LARR #22668 3. CONCRETE SLAB 4. 1/2" DRYWALL 4 123 1. NOTCH IN PLATE 2. 1 3/4" MAX. IF BORED HOLE EXCEED 1 3/4" IN 2x4 TOP PLATE OR 2 3/4" IN 2x6 TOP PATE, STRAP E/S OF PLATE W/ITEM #3 BELOW 3. SIMPSON CS 1 6x4" LONG METAL STRAP, TYPICAL @ EACH PLATE CUT W/(6) 16d's EACH SIDE. 4. PIPE WHERE OCCURS 5. TOP PLATES-SILL PLATES 6. ANCHOR BOLTS PER PLANS 7. LOCATE ANCHOR BOLT 5" MIN. 9" MAX. AWAY FROM NOTCH OR END OF PLATE NOTE: IF NOTCH OR HOLE EXCEEDS 50% OF TOP PLATE WIDTH, USE SIMPSON ST6224, STAGGERED @ E/S OF PLATES, USE SIMPSON NS AS NEEDED. 4345 1 2 5 37 DEPT H 1/2 DEPTH 3" MAX. 1. NOTCH DEPTH & BORED HOLD SEE TABLE BELOW. 2. STUD 3. STILL PLATE 4. HOLE EDGE DISTANCE 5/8" MIN. NOTE: BORED HOLES NOT PERMITTED IN MORE THAN TWO CONSECUTIVE DOUBLE STUDS BORED HOLES STUD SIZE EXTERIOR & BEARING WALLS NON- BEARING WALLS 2x4 2x6 2-2x4 2-2x6 % 1 7/16" 2 1/8" 40% 2 1/8" 2 1/8" 60% 2 3/16" 3 5/16" 3 5/16" 3 5/16" STUD SIZE EXTERIOR & BEARING WALLS NON- BEARING WALLS NOTCH DEPTH 2x4 2x6 % 7/8"1 7/16" 1 3/8"2 3/16" 25%40% 1 4 2 3 4 1 d MIN. PER SCHEDULE 3" M I N . PE R S C H E D U L E 2% SLOPE MIN. 1 2 3 4 REBAR (SEE FOOTING SCHEDULE) MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 1/2" FIBER BOARD EXPANSION JOINT MIN. 4" THK. CONC. SLAB W/ #3 REBARD @18" O.C O/ COMPACTED SOIL 234 1 ANCHOR BOLTS (AB) SHALL BE 5/8" WITH 3"X3'X0.229" THICK PLATE WASHERS. SPACING OF ANCHOR BOLTS SHALL NOT EXCEED 6'-0" O.C. EACH SECTION OF PLATE SHALL HAVE A MINIMUM OF TWO AB. ANCHOR BOLTS SHALL BE EMBEDDED A MINIMUM OF 7" INTO FOOTING. HOLES SHALL BE 1/32" TO 1/6" LARGER THAN AB. LARGER HOLES SHALL BE REPAIRED WITH EPOXY. PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR NOT HEM-FIR. 12 " M A X . 5" M I N . 12" MAX 5" MIN. 12 " M A X 5" M I N . 12" MAX 5"MIN. 12" MAX 5" MIN 2" M A X AB SPACING 6' MAX OR PER SHEAR WALL SCHEDULE (TYP) PANEL PER PLAN (TYP.) AT CORNER AT INTERSECTION AT SPLICE TRUSS WHERE OCCURS PER PLAN SIMPSON "DTC" @48" O.C. MAX. 2X BLK'G. @48" O.C. W/ (3) 16d'S @ EA.END JOIST OR TRUSS BOTT. CHORD 1X OVER 2X PLATE3/ 4 " T Y P . NON-BRG. WALL WOOD POST PER PLAN CONCRETE SLAB PER PLAN VAPOR BARRIER IN DIRECT CONTACT W/ CONC. SLAB PER ARCH. PLANS 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATEMI N . 1' - 6 " CL R . 0' - 3 " REINFORCING PER PLAN CONT. FT'G BEYOND SIMPSON CP PER PLAN COLUMN BASE SCHEDULE CB44 W/2-1/2" DIA.. M.B. FOR 4x4 POST CB46 W/2-5/8" DIA.. M.B. FOR 4x6 POST CB66 W2-5/8" DIA.. M.B. FOR 6x6 POST CB88 W/2-3/4" DIA.. M.B. FOR 8x8 POST SEE PLAN EXTERIOR FINISH PER PLAN WATER RESISTIVE BARRIER, TYP 2x SOLID BLOCKING W/1/2"⌀x5" LAG SCREW AT KNEE BRACE BASE, TYP. 2x BLOCKING LAG SCREW, TYP EN SIMSON CO HUC46 HANGER, TYP 2X8 RESAWN LEDGER W/ 2-1/2"⌀x6" LAG SCREWS @ 16 OC NOTCH RAFTERS @ CONTINUOUS LOCATIONS ROOF SHEATHING PER CONSTRUCTION NOTES (N) 2X6 RR, SISTER WITH (E) RR W/ 8-16d NAIL EVERY 24" TN 2x BLKING TO 4x4 BM. 4x4 TRELLIS BEAM 3/8" ⌀x6" LAG SCREW FROM KNEE BRACE TO BEAM, COUNTERSUNK 3/8" ⌀x6" LAG SCREW FROM TRELLIS TO BEAM, COUNTERSUNK & COVERED WITH HARD PLASTIC PLUG FOR RAIN PROTECTION 4x6 TRELLIS BEAM EACH END METAL 'Z' FLASHING, TYP 4x4 RESAWN KNEE BRACE, TYP PLYWOOD SHEAR PANEL WHERE OCCURS SIMPSON KNEE BRACE KBSZ (E) STUD WALL (E) STUCCO WEEP SCREED . 4" MIN. ABOVE EARTH 2" MIN. ABOVE PAVEMENTF.G (E) FOOTING VAPOR BARRIER DRILL AND FILL WITH SIMPSON'S "SET-XP" EPOXY 2" EMBEDMENT LENGTH (E) DRYWALL (N) 3" CONC. 3,000 PSI @28 DAYS #3 @16" O.C. E.A. WAY (E) CONC. GARAGE SLAB .2" E.D. PER TABLE (N) HOLD DOWN PER PLAN (E) 2X STUD TYP THREADED ROD W/ SIMPSON SET- XP EPOXY, ESR-2508 (SPECIAL INSP. REQ'D) 4X POST PER FRAMING PLAN (N) ANCHOR BOLTS PER SHR. WALL SCHED. W/ SIMP. SET EPOXY (N) 2x P.T. BET. STUDS (E) SILL PLATE (E) CONCRETE FOUNDATION HDU HDU2 HDU4 HDU8 BOLT ø EMBED E.D.CAPACITY 0'-0 5/8" 0'-0 5/8" 0'-0 7/8" 0'-10" 1'-0" 1'-6" 0'-1 7/8" 0'-1 7/8" 0'-1 7/8" 2306# 4234# 4353# BEAM PER PLAN CEILING JOIST PER PLAN SIMPSON LUS JOIST HANGER MSTA 36 AT BOTTOM 1-3/4" EDGE DIST. EQEQ 3" - 5 " 3" M I N . MI N . E M B E D M E N T "l e " 3" - 4" POST PER PLAN (4x MIN.) FASTENERS PER MANUF. SIMP. HOLDOWN PER PLAN (PHD SHOWN) #4 CONT. REBAR 2x, 2-2x OR 3x P.T.D.F. SILL P PER PLAN L SIMPSON "SSTB" PER SCHEDULE CONT. FTG. OR FDN. WALL SEE OTHER DETAIL FOR SIZE & REINF. . DEEPEN FTG. AS REQ'D. TO MAINTAIN A.B. CLEARANCE (12"x12" MIN. IN PLAN) NOTES: 1. FOR RAISED FOUNDATION USE SSTB FOR TWO POUR SYSTEM AND EXTEND BOLT BEYOND SILL PLATE ABOVE FLOOR SHEATHING, OR USE SIMP. CNW COUPLER FOR BOLT EXTENSION. 2. CONCRETE STEM WALLS SHALL BE 6"MIN WIDTH FOR 5/8⌀ ANCH., 8" MIN. WIDTH FOR 7/8"⌀ ANCH., 8" MIN. FOR CONC. BLK 3. VALUES BASED ON GOVERNING CAPACITY OF SSTB AT END OF CONC. WALL CONDITION (ICC#: ESR-2611) SCHEDULE SCHEDULE HDU2-SDS2.5 HDU4-SDS2.5 HDU5-SDS2.5 HDU8-SDS2.5 16 20 24 28 34 24 24 24 34 34 4x4 4x4 4x4 4x4 4x6 6-SDS 10-SDS 14-SDS 20-SDS 20-SDS # SDS SCREWS (1/4"⌀) MIN. POST EMBEDMENT "le" SSTB # 1-POUR SSTB # 2- POUR 2x4 KICKER @ 4' MAX.OC SIMPSON A35 45° M I N . FLUSH BEAM OR WALL PER PLAN C.J PER PLANS 'U' HANGERS SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 SD1 STRUCTURAL DETAILS 2025/02/06 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U CEILING JOIST TO BEAM STARP DETAIL WOOD POST BASE TO PAD DETAIL 01NEW FOOTING AT GARAGE DOOR 02AT CURB FOOTING 03HOLD DOWN TO EXISTING CONCRETE FOUNDATION 04FLUSH BEAM TO POST CONNECTION 05KING POST TO HEADER 06RAFTER AT EXTERIOR WALL 07DOWELL TO EXISTING FOOTING 08 09BEAM-CEILING JOIST-RIDGE CONNECTION 10HEADER TO POST 11FLUSH RIDGE 12NON-BEARING INT. WALL TYP., N.T.S.13PIPING THRU PLATE FRAMING, N.T.S.14FLUSH BEAM TO POST CONNECTION 15PORCH TO HOUSE FOOTING 16TYPICAL PLATE ANCHOR BOLTS 18INTERIOR WALL 19 KNEE BRACE TRELLIS OPENING CAP 21 RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N 20 NEW EXTERIOR FOOTING ..8"8" .12" DRILL AND FILL WITH SIMPSON'S "SET-XP" EPOXY 5" CONCRETE SLAB 3,000 PSI W/ #4 REBAR @16" OC. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 CG.1 CAL. GREEN REQUIREMENTS 05/03/2024 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 CG.2 CAL GREEN REQUIREMENTS 05/03/2024 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 T24-2 TITLE 24 SHEET 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 T24-1 TITLE 24 SHEET 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 GFI WP WP 220V EGD 3 4 D 220 vs FS CT R CLG SD T H J W TV AC CONDENSER WATER HEATER IAQ FAN IAQ FAN AC RETURN AIR VENT GAS GAS AC RETURN AIR VENT ATTIC ACCESS ATTIC ACCESS (N) OUTDOOR AC UNITS (E) WATER HEATER WITH ENCLOSURE ELECTRICAL SYMBOLS DUPLEX RECEPTACLE MOUNTED IN CEILING FOR GARAGE DOOR OPENER FLOOR MTD. RECEPTACLE POL BRASS RECEPTACLE 1/2 SWITCHED SINGLE POLE SWITCH 3 WAY SWITCH 4 WAY SWITCH DUPLEX RECEPTACLE ON ALL BRANCH CIRCUITS THAT SUPPLY 125- VOLT, SINGLE-PHASE, 15 & 20AMP RECEPTACLE OUTLETS IN DWELLING UNIT SHALL BE PROTECTED BY A COMBINATION TYPE (AFCI) ARC- FAULT CIRCUIT INTERRUPTER(S) PER 2010 CEC 210.12. FUSED SWITCH WATERPROOF RECEPTACLE DUPLEX RECEPTACLE ON GROUND-FAULT INTERRUPTED CIRCUIT DUPLEX RECEPTACLE LOCATED UNDER COUNTER 220V RECEPTACLE (VERIFY AMPERAGE REQUIREMENTS) RECESSED HIGH EFFICACY LIGHT FIXTURE WEATHER PROOF VAPOR PROOF, RECESSED, HIGH EFFICACY LIGH FIXTURE HANGING HIGH EFFICACY LIGHT FIXTURE - CHANDELIER I00 LB SUPPORT MIN. WALL MOUNTED HIGH EFFICACY LIGHT FIXTURE SURFACE MOUNTED HIGH EFFICACY LIGHT FIXTURE SOLAR POWERED, PHOTOCONTROL STEP MOUNTED LIGHT FIXTURE VENT / LIGHT COMBO, BY VENT AXIA CEILING EXHAUST FAN / FLUORESCENT LIGHT WHISPER FIT 4" DUCT. PANASONIC OR EQUAL STANDARD SERVICE TELEPHONE OUTLET CAT 5 COMBINED: COMPUTER DATA LINE AND TELEVISION CABLE OUTLET SMOKE DETECTOR SHALL BE PROTECTED BY AND ARC-FAULT CIRCUIT INTERRUPTER PER 2019 CEC 210.10. SMOKE DETECTORS SHALL HAVE A 10 YEAR BATTERY AND SHALL BE REPLACED 10 YEARS FROM THE DATE MARKED ON THE UNIT PER 2019 CBC 907.2.11.2, AND 2019 CRC R314 - R315. GAS LINE HOSE BIB JUNCTION BOX HEATING OUTLET IAQ FAN HUMIDISTAT CONTROL VACANCY LIGHT SWITCH 220 VOLT FUSED SWITCH SINGLE POLE SWITCH WITH DIMMER THERMOSTAT CARBON MONOXIDE ELECTRIC VEHICLE CHARGER VACANCY SENSOR UNDER-CABINET LED STRIP LIGHT DUPLEX RECEPTACLE LOCATED ABOVE CEILING CEILING EXHAUST FAN PANASONIC WHISPER FIT FAN 4" DUCT WITH HUMIDITY CONTROL HB GAS VS CM EVC C5 S VP DUPLEX RECEPTACLE FOR TELEVISION ELECTRIC PANEL INDOOR AIR HANDLER, MINI-SPLITAC F H ELECTRICAL ABBREVIATIONS A AMP AT AUTOMATIC TIME SWITCH CONTROL AST ASTRONOMICAL TIME CLOCK C/CW COLD WATER D DIMMER / DIMMABLE DED DEDICATED OUTLET / CIRCUIT EMCS EMERGENCY MANAGEMENT CONTROL SYSTEM (CENC 105 (K) 3,A,III,C) EV ELECTRICAL VEHICLE EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT FAU FORCED AIR UNIT FG NATURAL GAS FL FLOURESCENT FSR FIRE SPRINKLER RISER GFI GROUND FAULT CIRCUIT INTERRUPTER HB HOSE BIB HC HUMIDISTAT CONTROL HE HIGH EFFICACY H/HW HOT WATER JA8 COMPLAINT W/ APPENDIZ JA8 L, LED LED LIGHT FIXTURE LVL EVSE LEVEL MR MOISTURE RESISTANT (INDOOR) MS MOTION SENSOR PB PUSH BUTTON PC PHOTOCELL SOV SHUT OFF VALVE VS VACANCY SENSOR V VOLT WP WEATHER PROOF (RATED FOR EXTERIOR) ELECTRICAL NOTES CODE REFERENCES BASED ON 2022 CALIFORNIA ELECTRICAL CODE 1 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT. 2 3 4 5 NUMBER OF CEILING JUNCTION BOXES NOT CONTAINING INSTALLED LIGHTING OR OTHER DEVICES SHALL NOT EXCEED NUMBER OF BEDROOMS. ELECTRICAL BOXES MUST BE SERVED BY A DIMMER, VACANCY SENSOR OR FAN SPEED CONTROL. CENC 150 (k) 1B 6 ELECTRONIC BALLASTS ARE REQUIRED FOR ALL LAMPS RATED 13 WATTS OR GREATER. 7 ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A. (CENC 150 (k) 1A). 8 RECESSED LUMINAIRIES IN CEILINGS SHALL BE APPROVED FOR ZERO-CLEARANCE CONTACT (IC) & CERTIFIED AIRTIGHT, SHALL NOT CONTAIN SCREW BASED SOCKETS, AND SHALL BE SEALED WITH GASKET OR CAULK BETWEEN HOUSING AND CEILING, AND SHALL BE JA8 COMPLIANT, PER CENC 150.0 (k) 1C 9 DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINAIRES REQUIRED TO HAVE JA8 COMPLIANT LIGHT SOURCES - CENC 150 (k) 2K). a. LIGHTING IN CLOSETS LESS THAN 70 SQ.FT. ARE NOT REQUIRED TO BE JA8 COMPLIANT - CENC 150(k) 2, k, EX. 1 b.RECESSED LIGHT FIXTURES IN HALLWAYS ARE NOT REQUIRED TO BE JA8 COMPLIANT - CENC 150 (k) 2K, EX. 2 10 AT LEAST ONE LUMINAIRE IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS (CENC 150 (k) 2J). 11 UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING SYSTEMS. (CENC 150 (k) 2L). 12 EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. (OR SEE EXCEPTION - CENC 150 (k) 2B.) 13 14 ALL KITCHEN, BATHROOM, LAUNDRY ROOM, GARAGE AND EXTERIOR RECEPTACLES SHALL BE GFCI PER CEC 210.8(A) 15 ALL 125-VOLT, 15 AND 20 AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER- RESISTANT PER CEC 406.12 16 PROVIDE A MINIMUM OF 2-20 AMP CIRCUITS TO KITCHEN COUNTERTOPS FOR SMALL APPLIANCES PER CEC 210.11 (C) (1) 17 PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT PER CEC 210.11 (C) (2) 18 A DEDICATED 120V, 20 AMP CIRCUIT SHALL SERVE THE REQUIRED BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. CEC 210.11 (C) (3) 19 ALL BRANCH CIRCUITS SUPPLYING 12O-VOLT SINGLE-PHASE 15 & 20-AMPERE RECEPTACLE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER(S) PER CEC 210.12(A). 20 STRUCTURED WIRING PANELS LOCATED IN CLOTHES CLOSET SHALL NOT CONTAIN OVERCURRENT DEVICES PER CEC 240.24 21 A 120V ELECTRIC RECEPTACLE SHALL BE LOCATED WITHIN 3FT FROM THE WATER HEATER AND BE ACCESSIBLE TO THE WATER HEATER WITHOUT OBSTRUCTIONS. (CENC 150 (n)1A) 22 23 RECEPTACLES THAT ARE REQUIRED AT THE FRONT AND REAR OF THE HOME, AND ON BALCONIES, DECKS & PORCHES, MUST BE WITHIN 6 FEET 6 INCHES OF GRADE (AND WATERPROOF AND GFCI PROTECTED). CEC 210.52 (E) & 210.8(A) EXTERIOR LIGHT FIXTURES & WEATHERPROOF OUTLETS SHALL BE INSTALLED PER CEC 410.10(A) & 406.9, & CENC 150.0 (k) 3 EXTERIOR LIGHTING SHALL BE CONTROLLED BY MANUAL ON & OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE AUTOMATIC ACTIONS OF ITEMS ii OR iii BELOW. SHALL ALSO BE CONTROLLED BY ONE OF THE FOLLOWING: II. PHOTOCELL AND MOTION SENSOR OR III. ONE OF THE FOLLOWING: a. PHOTOCONTROL & AUTOMATIC TIMER b. ASTRONOMICAL TIME CLOCK c.RGY MANAGEMENT CONTROL SYSTEM (EMCS) AS NOTED CENC 150.0 (k) 3A INTERNALLY ILLUMINATED ADDRESS SIGNS SHALL:: a. COMPLY WITH CENC 140.8; or b. SHALL CONSUME NO MORE THAN 5 WATTS OF POWER AS DETERMINED ACCORDING TO CENC 130.0 ( c) 24 SMOKE ALARMS SHALL BE INTERCONNECTED W/ BATTERY BACKUP OR EMERGENCY ELECTRICAL SYSTEM CRC R314.4 25 SMOKE ALARMS SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: CRC R314.3 & R314.3.3 a. IN EACH SLEEPING ROOM b.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS c.ON EACH ADDITIONAL STORY LOCATION REQUIREMENTS: d.MIN. 3 FT. FROM BATHROOMS WITH TUBS OR SHOWERS. e. MIN. 20 FT. FROM PERMANENTLY INSTALLED COOKING e) APPLIANCES. OR SEE EXCEPTIONS NFPA 29.8.3.4 WHEN UNABLE TO ACHIEVE DISTANCE REQUIRED. f.MIN. 3 FT. FROM TIP OF SUSPENDED CEILING FAN BLADE. g.WITHIN 12 IN. VERTICALLY FROM HIGHEST POINT OF SLOPED OR COFFERED CEILINGS. h.3 FT. HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW FROM THOSE REGISTERS. 26 CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: CRC R315.3 a.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS b.ON EVERY OCCUPIABLE LEVEL, INCLUDING BASEMENTS c IN BEDROOMS CONTAINING A FUEL-BURNING APPLIANCE (I.E. FIREPLACE) ** COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE ALARMS OR CO2 ALARMS CRC R314.5, R314.7.4, & R315.4 31 COMBINATION SMOKE AND CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED AND RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, OR FROM A BATTERY BACKUP WHEN PRIMARY POWER IS INTERRUPTED (CRC R314 AND R315) 32 TWO OR MORE SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR (CEC 210-11(C) & 210-52(B)) FAN/LIGHTS LOCATED WITHIN 3FT HORIZONTALLY AND 8FT VERTICALLY OF THE BATHTUB RIM OR SHOWER STALL THRESHOLD SHALL BE LISTED FOR A DAMP OR WET LOCATION ARE SUBJECT TO SHOWER SPRAY. (PER CEC 410.10 (D) ) COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE ALARMS OR CO2 ALARMS (CRC R314.5, R314.7.4, & R315.4) 27 ATLEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS. EXCEPTION: CIRCUIT SHALL BE PERMITTED TO SUPPLY READILY ACCESSIBLE OUTDOOR RECEPTACLE OUTLETS (CEC 210.11) MECHANICAL NOTES CODE REFERENCES BASED ON 2022 CALIFORNIA MECHANICAL CODE 1. 2. 3. 4. 5. 6. 7. 8. a. b. 9. 10. 11. 12. 13. 14. 15. 16. 17. ROOMS CONTAINING TUBS, SHOWERS OR SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH CMC APPDX E 605.2 & CRC R303.3.1 INCLUDING ACCESSIBLE HUMIDISTAT CONTROL (CGBC 4.506.1) ALL EXHAUST DUCTS SHALL HAVE SMOOTH INTERIOR SURFACE AND TERMINATE OUTSIDE THE BUILDING AND SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER. (CMC 504.1) TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (i.e., CLOTHES DRYER VENTS, BATH AND UTILITY FANS, ETC.) SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING. PER CMC 502.2.1 DRYER VENT OUTLET SHALL BE MIN. 5 FT. FROM AIR CONDITIONING CONDENSER (CENC 150 (h) 3.A) PROVIDE MIN. 4" DIA. SMOOTH METAL DRYER VENT W/ BACKDRAFT DAMPER TO EXTERIOR. VENT RUN SHALL COMPLY WITH MNFR.'S SPECS. AND CMC 504.4.2 & 908. LENGTH OF RUN MAY EXCEED 14'-0" IF PERMITTED BY DRYER MNFR.'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING OF NOT LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS PER CMC 504.4.1 WHOLE BUILDING VENTILATION SHALL BE PROVIDED AND CONFIRMED THRU FIELD VERIFICATION & DIAGNOSTIC TESTING, PER CENC 150 (o) CALCULATION: 1 CFM PER 100 SF. FLOOR AREA PLUS NUMBER OF BEDROOMS PLUS ONE, MULTIPLIED BY 7.5 CFM. EXAMPLE: 1500 SF HOME W/ 3 BEDRMS = 15 CFM BLDG + 30 CFM PER OCCUPANT = 45 CFM REQUIRED. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOP OF NOT LESS THAN 30INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS (CMC 920.3.2) CLOTHES DRYER EXHAUST DUCT SHALL NOT BE CONNECTED TO A VENT CONNECTOR, GAS VENT OR CHIMNEY AND SHALL NOT TERMINATE INTO A CRAWL SPACE, ATTIC OR OTHER CONCEALED SPACE. EXHAUST DUCTS SHALL NOT BE ASSEMBLED WITH SCREWS OR OTHER FASTENING MEANS THAT EXTEND INTO THE DUCT AND THAT ARE CAPABLE OF CATHING LINT, AND THAT REDUCE THE EFFICIENCY OF THE EXHAUST SYSTEM. SCREENS SHALL NOT BE INSTALLED AT THE DUCT TERMINATION. WHERE JOINING OF DUCTS, THE MALE END SHALL BE INSERTED IN THE DIRECTION OF AIRFLOW (CMC 504.4) DOMESTIC CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14FT, INCLUDING TWO 90-DEGREE ELBOWS. A LENGTH OF 2FT SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO (CMC 504.4.2.1) CLOTHES WASHER STANDPIPES SHALL BE 2INCH IN DIAMETER. NO TRAP FOR A CLOTHES WASHER STANDPIPE RECEPTOR SHALL BE INSTALLED BELOW THE FLOOR, BUT SHALL BE ROUGHED IN NOT LESS THAN 6INCHES AND NOT MORE THAN 18INCHES ABOVE THE FLOOR. (CPC 804.1) NO STANDPIPE RECEPTOR FOR A CLOTHES WASHER SHALL EXTEND MORE THAN 30INCHES AND NOT LESS THAN 18INCHES ABOVE ITS TRAP. (CPC 804.1) SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : OC - A D U 24 8 8 1 A L I C I A P K W Y , S T E . E- 2 2 2 , L A G U N A H I L L S 94 9 - 4 1 4 - 8 7 9 9 A5 PROPOSED ELECTRICAL PLAN 2025/01/20 10 1 2 W 3 R D S T U N I T # 1 & # 2 ( D U P L E X ' S ) 10 1 4 W 3 R D S T U N I T # 1 & U N I T # 2 ( A D U ' S ) NE W D E T A C H E D AD U SCALE: 1/4" = 1'-0"1 PROPOSED ELECTRICAL PLAN N RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SANTA ANA CITY COUNCIL Valerie Amezcua Mayor vamezcua@santa-ana.org Thai Viet Phan Mayor Pro Tem, Ward 1 tphan@santa-ana.org Benjamin Vazquez Ward 2 bvazquez@santa-ana.org Jessie Lopez Ward 3 jessielopez@santa-ana.org Phil Bacerra Ward 4 pbacerra@santa-ana.org Johnathan Ryan Hernandez Ward 5 jryanhernandez@santa-ana.org David Penaloza Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall October 28, 2024 Also sent via email to: only_hp@hotmail.com Hugo Prado 1012 W 3rd Street Santa Ana, CA 92703 Subject: Address Assignment for the new ADUs (2) located at 1012-1014 West 3 rd Street (APN: 405-163-17) in Santa Ana, CA Dear Mr. Prado, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for the existing duplex and the new proposed ADU conversions located at 1012-1014 West 3rd Street (APN: 405-163-17). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 1. 1012 W 3rd street Unit 1 (existing duplex, front unit) 2. 1012 W 3rd street Unit 2 (existing duplex, rear unit) 3. 1014 W 3rd street Unit 1 (new ADU, front unit) 4. 1014 W 3rd street Unit 2 (new ADU, rear unit) To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 664-2792 or by email at farias@santa-ana.org. Sincerely, Fernanda Arias Assistant Planner II Exhibit A – Address Plan HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 Address Letter for 1012-1014 West 3rd Street Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Principal Sergio Verino, Code Enforcement Principal HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 THIRD STREET 45.00' PROPERTY LINE 45.00'PROPERTY LINE 12 5 . 0 0 ' PR O P E R T Y L I N E 12 5 . 0 0 ' 12 5 . 0 0 ' PR O P E R T Y L I N E 12 5 . 0 0 ' 40 ' - 0 " 13 ' - 6 " 22' - 6" 5' - 0"12' - 6"27' - 6" 18 ' - 1 " FIRE SEPARATION DISTANCE LINE (E) SINGLE-FAMILY DWELLING CONVERSION TO ADU 12 ' - 0 " (E ) C O N C R E T E D R I V E W A Y (E) GARDEN 103.8' 12 5 ' - 0 " 45' - 0" 22' - 6" (E) DETACHED GARAGE LEGALIZE UNPERMITTED PATIO SETBACK 5' - 0" 1012 W 3rd St Unit 1 1012 W 3rd St Unit 2 1014 W 3rd St Unit 1 1014 W 3rd St Unit 2 PATH OF TRAVEL FROM THIRD STREET TO (E) SINGLE FAMILY DWELLING PATH OF TRAVEL FROM THIRD STREET TO NEW DETACHED ADU DRAWINGS PROVIDED BY: EM SOCAL ENGINEERING 24881 ALICIA PKWY, STE. - 222, LAGUNA HILLS, CA 92653 760-484-6343 1012 & 1014 W THIRD ST, SANTA ANA, CA 92703 SCALE: 1" = 20'-0" 1 PROPOSED SITE PLAN Exhibit A HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 2 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 3 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2) Space Heating 0 1.59 0 9.29 0 -7.7 Space Cooling 0 44.63 0 20.55 0 24.08 IAQ Ventilation 0 5.17 0 5.17 0 0 Water Heating 0 35.08 0 28.03 0 7.05 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 0 86.47 0 63.04 0 23.43 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 6.93 0 6.93 Appl. & Cooking 0 67.82 0 66.86 Plug Loads 0 81.71 0 81.71 Outdoor Lighting 0 6.03 0 6.03 TOTAL COMPLIANCE 0 248.96 0 224.57 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 4 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 33.56 31.14 2.42 7.21 Net EUI2 33.56 31.14 2.42 7.21 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Verified heat pump rated heating capacity ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Dn ADU Conditioned hvac1 450 8 DHW Sys 1 New 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 5 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Back Dn Dn ADU 2x4 wall 270 Back 160 0 90 Extension New Left Dn Dn ADU 2x4 wall 180 Left 175 0 90 Extension New Front Dn Dn ADU 2x4 wall 90 Front 160 56 90 Extension New Right Dn Dn ADU 2x4 wall 0 Right 175 0 90 Extension New Roof Dn ADU Roof Attic n/a n/a 450 n/a n/a New ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Dn ADU Attic RoofDn ADU Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window 1 Window Front Dn Front 90 1 20 0.28 NFRC 0.23 NFRC Bug Screen Window 4 Window Front Dn Front 90 1 16 0.28 NFRC 0.23 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door 1 Front Dn 20 0.2 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 6 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Dn ADU 450 88 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers 2x4 wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofDn ADU Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 7 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem PROPH40 T2 RH37515 (40 gal, JA13) Outside Dn ADU Dn ADU WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type hvac1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a Setback 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 8 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Multi-split HP-ductless 1 HSPF2 9 25000 18500 EER2SEER2 15 11 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Not Required Not Required No No Yes Yes INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam ADU IAQVentRpt 29 0.35 Exhaust No n/a / n/a No Yes 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 9 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Kevin Laughton Tailored Energy Services 01/17/2025 548 Market Street #30051 San Francisco, CA 94120 888-310-0808 Kevin Laughton Tailored Energy Services 01/17/2025 548 Market Street #30051 San Francisco, CA 94120 888-310-0808 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 2 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 3 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2) Space Heating 0 1.59 0 9.29 0 -7.7 Space Cooling 0 44.63 0 20.55 0 24.08 IAQ Ventilation 0 5.17 0 5.17 0 0 Water Heating 0 35.08 0 28.03 0 7.05 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 0 86.47 0 63.04 0 23.43 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 6.93 0 6.93 Appl. & Cooking 0 67.82 0 66.86 Plug Loads 0 81.71 0 81.71 Outdoor Lighting 0 6.03 0 6.03 TOTAL COMPLIANCE 0 248.96 0 224.57 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 4 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 33.56 31.14 2.42 7.21 Net EUI2 33.56 31.14 2.42 7.21 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Verified heat pump rated heating capacity ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Dn ADU Conditioned hvac1 450 8 DHW Sys 1 New 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 5 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Back Dn Dn ADU 2x4 wall 270 Back 160 0 90 Extension New Left Dn Dn ADU 2x4 wall 180 Left 175 0 90 Extension New Front Dn Dn ADU 2x4 wall 90 Front 160 56 90 Extension New Right Dn Dn ADU 2x4 wall 0 Right 175 0 90 Extension New Roof Dn ADU Roof Attic n/a n/a 450 n/a n/a New ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Dn ADU Attic RoofDn ADU Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window 1 Window Front Dn Front 90 1 20 0.28 NFRC 0.23 NFRC Bug Screen Window 4 Window Front Dn Front 90 1 16 0.28 NFRC 0.23 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door 1 Front Dn 20 0.2 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 6 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Dn ADU 450 88 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers 2x4 wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofDn ADU Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 7 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem PROPH40 T2 RH37515 (40 gal, JA13) Outside Dn ADU Dn ADU WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type hvac1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a Setback 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 8 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Multi-split HP-ductless 1 HSPF2 9 25000 18500 EER2SEER2 15 11 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Not Required Not Required No No Yes Yes INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam ADU IAQVentRpt 29 0.35 Exhaust No n/a / n/a No Yes 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:ADU Calculation Date/Time:2025-01-17T00:28:16-08:00 (Page 9 of 9) Calculation Description:Title 24 Analysis Input File Name:18741 1012 & 1014 W THIRD ST., SANTA ANA, CA (Garage to ADU conversion) adu add Lyndon.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-01-17   00:28:37 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Kevin Laughton Tailored Energy Services 01/17/2025 548 Market Street #30051 San Francisco, CA 94120 888-310-0808 Kevin Laughton Tailored Energy Services 01/17/2025 548 Market Street #30051 San Francisco, CA 94120 888-310-0808 425-P010016222A-000-000-0000000-0000 01/17/2025 00:31 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 STRUCTURAL CALCULATIONS FOR: 1014 W. 3RD ST. SANTA ANA, CA GARAGE CONVERSION Engineer: HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 TABLE OF CONTENTS I. DESIGN CRITERIA 3 II. LOADS 4 III. SEISMIC DESIGN 4 IV. GRAVITY DESIGN 7 V. FOUNDATION 5 VI. LATERAL ANALYSIS 6 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 CODE: 2022 CALIFORNIA BUILDING CODE WITH LOCAL ADDENDA Timber Douglas Fir Larch Rafters & Joints: #2 Grade Beams & Headers: As noted on plans Concrete F c’ = 2,500 PSI @ 28 days Reinforcing Steel ASTM A-615 #4 & Smaller, Grade #5 & Larger, Grade Soil Value 1,500 PSF per Soils IBC Typical Weights: Item PSF R-38 INS 1.5 ½ Gyp Board 2.2 Roofing (Shingles) 3.0 2x4 @ 16” O.C 1.1 2x6 @ 16” O.C 1.7 2x6 @ 24” O.C 2.3 2x8 @ 24” O.C 1.5 ½ Plywood 1.5 Stucco (7/8) 10.0 R-13 0.5 R-19 0.8 2x10 @ 16” O.C. 3.0 2x10 @ 24” O.C. 2.0 2x12 @ 16” O.C. 3.3 2x12 @ 24” O.C. 2.4 14” TJI Joist 4.2 TPO Roofing 0.5 ¾ Plywood 3.0 Rigid Fiberglass (1” thick) 1.5 5/8 Gyp Board 2.8 5/8 Gyp Type X 3.0 2x4 Interior Walls 10.0 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 3/8” Plywood 1.1 5/8” Plywood 1.8 ¾” Plywood 2.2 Glasss Wool 0.2 Ceramic Tile, ¾” 10.0 Wood Paneling 2.5 Clay Roof Tile 6.5 Hardie Board 2.3 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 LOADS Wall Loads (Exterior) 2x4 @ 16 1.1 ½ CDX Plywood 1.5 ½ Gyp Board 2.5 R-13 0.5 Siding 10.0 TOTAL 15.6+MISC = 17 DEAD LOAD Roof Loads Asphalt Shingles 3 Framing 2x6 @ 16 O.C. 1.7 Roofing Paper 0.3 ½ Plywood 1.5 TOTAL 6.5 = 7 PSF Dead Load 20 PSF Live Load Ceiling Loads R-38 1.5 Framing 2x6 @ 16 O.C. 1.7 DryWall 2.2 TOTAL 5.4 = 6 PSF Dead Load 10 PSF Live Load HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 SEISMIC DESIGN HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025                           !"  #$#%&'&()*&+,-&+./,.&0/.-&10&234$(-&5+0 6.,7,8*9-&6:/;7,8*9<&((=4%>?2%?-&@##4=?4?3(24 A.,9 BCDECDFDBGHDIHFBJK A9L7;/&1:*9&M9N9)9/O9&A:O8P9/,JQRSTUG M7LV&1.,9;:)W XX +7,9&1Y.LL ZTZ[  UU B I\ ]W^9 _.Y89 A9LO)7^,7:/ U DE`KQRa     [ F D   \ U F BGD KQRa     [ U F \ KU ``B  T        KU T  UU B b  T        ZU FIG c      F D  J ZU T  UU B b c      U F  J ]W^9 _.Y89 A9LO)7^,7:/ ZQ T  UU B b       d eU D       F D  e T  UU B b       U F  fJ F `Bb KQR!     efJ U D       fJ fJK F G`S     !     gh b h T        ag U DE` f     !T      [F D  \ i U IEB e     Tj [Dk   d "    `Fd\    Z U `DB e           [F D  \ Uag F BGD f     !T      [U F  \ Ui F BEE e     Tj [Dk   d "    `Fd\    UZ F G e           [U F  \ fJ F GID e           [f!  J  \ fJi F `Bb   Tj [Dk   d "    `Fd\f!  J   QaF EDE K    !     QaU F ED` K    !    U Ql U I`E l    BCDECDBGHDIJK    Z K HCC    UCD HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025          !  ""  #  # "#$%        "  " "#      "&      "#"  #  ##'     $ !   "      "("'"     '& ) '     " " *" "      ' # ' "      #  $+     "  #  '" "$+ ""    # # ' '"  '   "  '     "  '  #  " ' "     "   $ ,-.-,/0-1 +$$   ' 0$  $'-- HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 DRAG LINE LEGENDS: NTS. HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 GRAVITY DESIGN HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 sheet no.:A2 Project:1014 W 3RD ROOF: roof DL+Celing DL= 20 psf partitions=5 psf W roof=25 psf 2ND FLOOR:floor DL=0 psf partitions=0 psf w floor=0 psf W Total=25 psf Latitude;33.83683 longitude:-118.0176 Ss 1.295 S1 0.462 Site Class:D Risk Category:II ASCE 7 Table 1.5-1 Ie=1 ASCE 7 Table 1.5-2 Fa=1.2 SMS 1.554 SDS 1.036 D ASCE 7 Table 11.6-1 rho=1.3 Plywood Shear Walls 6.5 ASCE 7 Table 12.2-1 Base Shear Coefficient SDS*I/R=Cs=0.159 (Strength) 0.7SDS*I/R Cs=0.145 (Service) V=CsW=V=5.00 psf Seismic Calcs 25 lb/sf Lb 900 sf 8,505 lb 125.08 ft 4 ft 17 lb/sf 31,005 lb 5.00 lb/sf Wind Load Calcs 9.6 lb/sf L=40 6,912 lb W=22.5 3,888 lb LATERAL ANALYSIS (ASCE 7-16) STORY WEIGHTS: SEISMIC: Maximum Short Period Response: maximum 1 sec. Period Response: Importance Factor: Site Coefficient: EQUIVALENT LATERAL FORCE PROCEDURE (ASCE 7 Section 12.8): Site Spectural Accel Value Design Response: Seismic Design Category: Redundancy Factor Seismic Force Resisting System Response Modification Factor Wroof = Bld. Area x Roof SF weight= Bld. Area= 22,500 Wwall = Bld. Circumference x (ceiling heigh/2)x wall wight per LF Bld. Circumference = Wind Load= Wind Pressure x Wall Height x L x 2= Wind Load= Wind Pressure x Wall Height x W x 2= Celing Heigh / 2 = Wall Wight = Wtotal= Wroof + Wwall = V = Cs x Wtotal/Bld Area = Wind Pressure (16 lb/sf) x 0.6 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 sheet no.:A3 Project:1014 W 3RD ST 5.00 psf Mbal= ((0.6-0.14SDS)xDL) X L^2/2 Seismic Wall NO. Lw Total (ft) HW (FT) Trib. Area (sf) V (pounds) Add'l Shear V/L (plf) **Wall Type Smallest DL (plf) OTM (ft-lbs) Mbal (ft- lbs) Uplift (lbs) Simpson Holdown 1 12 9 450 2249 187 2 4 100 6746 364 1595 HDU4 2 12 9 450 2249 187 2 4 100 6746 364 1595 HDU4 WIND: Wall NO. Lw Total (ft) HW (FT) Trib. Area (sf)V/L (PLF) **Wall Type Smallest OTM (ft-lbs) RM (ft- lbs) Uplift (lbs) Simpson Holdown 1 12 9 450 288 2 4 10368 1368 2387 HDU4 2 12 9 450 288 2 4 10368 1368 2387 HDU4 OTM= OTM= (V/L (plf x Lw) x Hw RM= RM= (Wall DL(psf) x Lw x Hw) x (Lw/2) T&C= T&C= (OTM - (0.6*RM))/Lw Seismic Wall NO.Lw Total HW Trib. Area V Add'l V/L (plf)**Wall Smallest DL (plf)OTM Mbal (ft-Uplift Simpson A 8 9 450 2249 281 1 2 100 5059 91 2484 HDU4 B 8 9 450 2249 281 1 2 100 5059 91 2484 HDU4 WIND: Wall NO.Lw Total HW Trib. Area V/L (PLF)**Wall Smallest OTM RM (ft-Uplift Simpson A 8 9 450 243 1 2 4374 342 2084 HDU4 B 8 9 450 243 1 2 4374 342 2084 HDU4 Wall type Nailing Capaciy (plf) Simpson Hold Down Capacity (lbs) 1 8d at 6" o.c. 260 HDU2 2306 2 8d at 4" o.c. 380 Wall A,B, 1&2 HDU4 3424 3 8d at 3" o.c. 490 HDU5 4234 *Capacities have been reduce by 25% DESIGN LATERAL FORCES ON SHEAR WALLS Roof Diaphragm Shear= Cs X 1.0= HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)300 @ 2 1/2"2231 (3.50")Passed (13%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)266 @ 8 11/16"1238 Passed (21%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)884 @ 6' 3 1/2"1178 Passed (75%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.413 @ 6' 3 1/2"0.641 Passed (L/372)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.740 @ 6' 3 1/2"0.855 Passed (L/208)--1.0 D + 1.0 Lr (All Spans) Member Length : 13' 5" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 4/12 All Product Solutions Depth Series Plies Spacing Cost Index 5 1/2"1 3/4" 1.55E TimberStrand® LSL 1 19.2"0.78 * 5 1/2"2 x DF No.1 1 16"0.88 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. SOLUTIONS REPORT PASSED The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. Level, Roof: Joist Current Solution: 1 piece(s) 2 x 6 DF No.1 @ 16" OC ForteWEB Software Operator Job Notes 4/29/2024 1:53:10 PM UTC Ehab Elias Structural Ventures (760) 484-6343 eliasehab@gmail.com ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 File Name: rafters Page 1 / 1 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)210 @ 2 1/2"2231 (3.50")Passed (9%)--1.0 D + 1.0 L (All Spans) Shear (lbs)185 @ 9"990 Passed (19%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)617 @ 6' 3 1/2"819 Passed (75%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.279 @ 6' 3 1/2"0.608 Passed (L/523)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.465 @ 6' 3 1/2"0.811 Passed (L/314)--1.0 D + 1.0 L (All Spans) Member Length : 12' 7" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 All Product Solutions Depth Series Plies Spacing Cost Index 5 1/2"1 1/2" 1.3E TimberStrand® LSL 1 19.2"0.56 * 5 1/2"2 x DF No.1 1 16"0.88 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. SOLUTIONS REPORT PASSED The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. Level, Ceiling: Attic Joist Current Solution: 1 piece(s) 2 x 6 DF No.1 @ 16" OC ForteWEB Software Operator Job Notes 4/29/2024 1:55:10 PM UTC Ehab Elias Structural Ventures (760) 484-6343 eliasehab@gmail.com ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 File Name: rafters Page 1 / 1 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1577 @ 2"8181 (3.50")Passed (19%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1304 @ 11"4675 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3913 @ 5' 3 1/2"5156 Passed (76%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.138 @ 5' 3 1/2"0.342 Passed (L/888)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.239 @ 5' 3 1/2"0.512 Passed (L/514)--1.0 D + 1.0 L (All Spans) Member Length : 10' 7" System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD All Product Solutions Depth Series Plies Cost Index 11 7/8"1 1/4" 1.3E TimberStrand® LSL 1 19.30 * 7 1/2"6 x DF No.1 1 66.00 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. SOLUTIONS REPORT PASSED The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. Level, Floor: Drop Beam Current Solution: 1 piece(s) 6 x 8 DF No.1 ForteWEB Software Operator Job Notes 4/29/2024 1:59:49 PM UTC Ehab Elias Structural Ventures (760) 484-6343 eliasehab@gmail.com ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 File Name: rafters Page 1 / 1 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025 HISTORIC - 1012 W Third St & 1014 W Third St Unit 1 & Unit 2 4/14/2025