Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1902 W Monica Ln - Plan
Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 SYSTEM SIZE: 9600 DC SYSTEM SIZE: 6960 AC CEC POWER OUTPUT: 9024 CEC BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: COVER SHEET 001 CS JURISDICTION STAMPS ADDITIONAL SCOPE OF WORK MAIN PANEL UPGRADE: N/A DERATE MAIN BREAKER: N/A EV CHARGER: N/A ESS: (1) FRANKLIN WH APOWER X AT 13.6kWh EACH BATTERY TO BE INSTALLED AT LEAST 3' FROM GAS, WINDOWS, AND DOORS (DIRECTLY ENTERING THE DWELLING). ESS IS NOT SUBJECT TO VEHICLE IMPACT. LOCATION: OUTDOORS ON EXTERIOR WALL UPSIZE MAIN BREAKER: N/A INSTALLER NOTES: PROPERTY INFORMATION OWNER: JOSE LUIS MELGOZA PHONE: 1714-605-4542 EMAIL: jesusmelgoza1221@gmail.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: SANTA ANA (CA) UTILITY: SOUTHERN CALIFORNIA EDISON DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 100 MPH ROOF SURFACE: 2979 SQ FT PV SQ FOOTAGE: 504.5 SQ FT PV COVERAGE: 16.94 % WEIGHT OF EQUIPMENT: 1144.6 LBS WEIGHT PER ATTACHMENT: 21.20 LBS DISTRIBUTED WEIGHT: 2.27 PSF NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 10104209 LOT AREA: 6497 LIVING AREA: 1624 SCOPE OF WORK MODULE INFORTMATION MODULE QTY: 24 MODULE MFG: LONGI MODULE MODEL: LR5-54HABB-400M ENERGY STORAGE SYSTEM INFORMATION STORAGE QTY: 1 STORAGE MFG: FRANKLIN WH STORAGE MODEL: APOWER X - 13.6kWh RAILING INFORMATION RAILING MFG: UNIRAC RAILING MODEL: UNIRAC SM LIGHT INVERTER INFORMATION INVERTER QTY: 24 INVERTER MFG: ENPHASE INVERTER MODEL: IQ8PLUS-72-2-US TABLE OF CONTENTS PAGE NUMBER PAGE TITLE 001 CS COVER SHEET 002 NS1 NOTES SHEET 003 SP1 SITE PLAN 004 PP1 PROPERTY PLAN 005 RF1 RACKING & FRAMING 006 LD1 LINE DIAGRAM 007 PP1 LABELS & PLACARD 008 OM1 OPTIMIZER MAP 009 JH1 JOB HAZARD ANALYSIS SS SPECIFICATION PAGES MOUNTING INFORTMATION MOUNT QTY: 54 MOUNT MFG & MODEL:UNIRAC FLASHLOC - MILL COMBINER INFORMATION COMBINER QTY: 1 COMBINER MFG: ENPHASE COMBINER MODEL: IQ COMBINER 5C This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. ** Bldg#: 101121637 Elec#: 20184530 Approvals Elec: M Smith 1902 W Monica Ln 12/2/2024 NOTES SHEET 002 NS1 JURISDICTION NOTES ELECTRICAL NOTES CONSTRUCTION NOTES UTILITY NOTES 1.ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3.ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5.A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH OSHA REGULATIONS. 6.MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7.ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8.CONDUIT, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY. THIS EQUIPMENT SHALL ALSO BE LOCATED AS CLOSE AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. 9.MODULES MUST HAVE 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. CODE REFERENCES GENERAL NOTES 1.RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2022 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND 2022 CALIFORNIA FIRE CODE. 2.CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3.THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4.A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5.EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6.ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8.CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9.ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA GREEN CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY CODE 1.PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2.ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3.WEATHERPROOF J-BOX – NEMA 3R. 4.ROOFTOP CONDUIT SHALL BE A MINIMUM OF 7/8" ABOVE THE ROOF SURFACE. 5.ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. INSTALLER NOTES JURISDICTION STAMPS DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 1902 W Monica Ln 12/2/2024 N SITE PLAN 003 SP1 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE:1" = 12' NOTES: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1902 MONICA LN, SANTA ANA, CA 92706 JURISDICTION STAMPS MODULE QTY:24 MODULE MFG:LONGI MODULE MDL:LR5-54HABB-400M DRIVEWAY PROPERTY LINE ROOF ACCESS POINT PER CRC 2022 (R324.6) (N) AC DISCONNECT (N) BATTERY (N) BACKUP GATEWAY (E) MAIN SERVICE PANEL (N) SUB PANEL (N) IQ COMBINER This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 1902 W Monica Ln 12/2/2024 MSP SUB AC BG IQC B CONDUIT RUN TO BE DETERMINED IN FIELD DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE:1" = 10' N ARRAY 1: MODULE QTY:15 TILT:18° AZIMUTH:270° MATERIAL:Comp Asphalt Shingles ARRAY 2: MODULE QTY:9 TILT:16° AZIMUTH:180° MATERIAL:Comp Asphalt Shingles 004 RP1 ROOF DETAILS FIRE CODE SETBACK BACKUP GATEWAY JB JUNCTION BOX LEGEND: MAIN SERVICE PANEL PV METER MSP PV SUB PANELSUB AC DISCONNECT AC LOAD CENTERACL EV CHARGER BATTERY EV B UM UTILITY METER (IF SEPARATED) DC DISCONNECT BG EMT CONDUIT PVC TRENCH DC AC BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 INVERTERINV (E) SOLAR MODULE ROOF PLAN JURISDICTION STAMPS MAIN BREAKER ENCLOSUREMBE SC SYSTEM CONTROLLER IQ COMBINERIQC ARRAY 2 ARRAY 1 3'1'-6" 3' This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 1902 W Monica Ln 12/2/2024 FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE 48" 2x6 RAFTER @ 24" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT 2x6 RAFTER TYPICAL SOLA R M O D U L E S DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: RACKING & FRAMING DETAILS 005 RF1 TYP ROOF ATTACHMENT PLANATTACHMENT DETAIL FRONT VIEW TYP FRAMING DETAIL JURISDICTION STAMPS BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 INSTALLER NOTES: This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 1902 W Monica Ln 12/2/2024 (N) FRANKLIN WH aGATE X [CRD-PCS NEM] (N) 125A BACKED UP LOADS PANEL 120/240V NEMA 3R UL LISTED (N) 40A (N) 30A RELOCATING LOADS TO BACKED UP LOADS PANEL (NO EV OR LOADS OVER 30A) (N) (1) FRANKLIN WH aPOWER X CAPACITY: 13.6kWh CONT. POWER: 5kW PEAK POWER: 10kW FRANKLINWH TECHNOLOGIES CO,.LTD./aPOWER X [240V] [SI1-SB] **IMPORTANT NOTE** SEE INSTALL MANUAL FOR PLACEMENT OF CT's (N) VISIBLE/ LOCKABLE AC DISCONNECT 30A AC NON-FUSED 240V, NEMA3R EATON DG221URB,240V 30A,2P,3R (N) 100A 4 4 5 5 JUNCTION BOX NEMA 3R 2 1 20A 20A DC AC + - ~ ~ DC AC + - ~ ~ DC AC + - ~ ~ DC AC + - ~ ~ DC AC + - ~ ~ DC AC + - ~ ~ BRANCH 1: (12) LONGI LR5-54HABB-400M MODULES W/ ENPHASE IQ8PLUS-72-2-US MICROINVERTERS BRANCH 2: (12) LONGI LR5-54HABB-400M MODULES W/ ENPHASE IQ8PLUS-72-2-US MICROINVERTERS 1 ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE (N) 125A ENPHASE IQ COMBINER 5C BOX W/ ENPHASE IQ GATEWAY X-IQ-AMI-240-5C 120/240V NEMA 3R GATEWAY 3 10/15A PER MANUFACTURER'S SPECIFICATIONS, IQ GATEWAY FOR MONITORING IN IQ COMBINER CAN ACCEPT EITHER 10A OR 15A BREAKER. IQ GATEWAY MONITORING BREAKER IN IQ COMBINER SUBJECT TO EQUIPMENT AVAILABILITY BY DISTRIBUTOR METER NUMBER: 222013518729 ROOFTOP CONDUIT SHALL BE A MINUMUM OF 7/8" ABOVE THE ROOF SURFACE (E) GROUNDING ELECTRODE (COPPER) GROUND ROD MAIN (E) 200A (N) 100A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/200A MAIN SERVICE PANEL 240/120V 1-PH, 3-W MAIN BONDING JUMPER TO UTILITY GRID (OVERHEAD) SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER ! DO NOT INSTALL ANY ADDITIONAL BREAKERS IN PANEL WARNING IF RELOCATING CIRCUITS MORE THAN 6' AFCI PROTECTION REQUIRED ALL LOADS TO BE RELOCATED FROM MSP (EXCEPT 50A A/C LOAD) POINT OF INTERCONNECTION LOAD SIDE 705.12(B)(3)(3) (E) 50A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID CONDUCTOR (CU)CONDUIT CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%)BASE AMP.DERATED AMP. TERM. TEMP. RATING 2 #10 THWN-2, in conduit 3/4" EMT 4 & (1)G #8 0.91 SEE CALCS SEE CALCS 40 36.4 90 1 #12 Q CABLE, in open air N/A N/A #10 0.91 SEE CALCS SEE CALCS 30 27.3 90 3 #8 THWN-2, in conduit 3/4" EMT 3 & (1)G #8 0.91 29.04 36.3 55 50.05 90 4 5 #3 THWN-2, in conduit 1" EMT 3 & (1)G #8 0.91 115 104.65 90 #10 THWN-2, in conduit 3/4" EMT 3 & (1)G #8 0.91 20.8 26 40 36.4 90 BRANCH CALCULATIONS BRANCH CIRCUIT DETAILS BRANCH 1 BRANCH 2 INVERTERS PER BRANCH 12 12 CONTINUOUS AC CURRENT 14.52 14.52 MAX AC CURRENT (125%) 18.15 18.15 SYSTEM SUMMARY ARRAY PTC POWER MODULE SPECS LONGI LR5-54HABB-400M PMAX 400W PTC 376W ISC 13.72A IMP 12.93A VOC 37.05V VMP 30.94V TEMP. COEFF. OF VOC -0.265 INVERTER SPECS IQ8PLUS-72-2-US AC VOLTAGE 240V GROUND 0.97 MAX OCPD 20A RATED POWER 290W MAX OUTPUT 1.21A MAX INPUT 20A MAX INPUT 60V EFFICIENCY 0.97CEC ARRAY STC POWER 9600W 9024W MAX AC CURRENT MAX AC POWER 290W DESIGN TEMPERATURES ASHRAE 2% HIGH 30°C 2°C ASHRAE EXTREME LOW 29.04A AHJ/UTILITY NOTES: INSTALLER NOTES: ENPHASE MICROINVERTERS RSD COMPLIANT PER 690.12 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: LINE DIAGRAM & DESIGN TABLES 006 LD1 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 JURISDICTION STAMPS This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 1902 W Monica Ln 12/2/2024 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION: MULTIPLE SOURCES OF POWER SERVICE BY QUALIFIED PERSONNEL ONLY N DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL SUB PANEL YOU ARE HERE PLACARD & PLACARD MAP 007 PP1 LABELING PLAN BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 INSTALLER NOTES: PROPERTY MAP NOTES: FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS 1902 MONICA LN, SANTA ANA, CA 92706 JURISDICTION STAMPS BACKUP GATEWAY AC DISCONNECT IQ COMBINER BATTERY THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY & SOLAR)6 [690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES 9 [705.12(B)(3)(3)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR [690.14(C)(2)] PLACE ON AC DISCONNECT AC DISCONNECT8AC PHOTOVOLTAIC POWER SOURCE 7 WARNING INVERTER OUTPUT CONNECTION DON'T RELOCATE THIS OVERCURRENT DEVICE PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) WARNING! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 3 [690.13(B)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 WARNING: PHOTOVOLTAIC POWER SOURCE [690.31(D)(2)] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM4 [690.56(C)(2)] PLACE ON INVERTER AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE5MAX AC OPERATING CURRENT: AC OPERATING VOLTAGE: MAX VAC240 [690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, CALIFORNIA FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [690.56(C)] PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE 11 LABEL LOCATED INSIDE PANEL NEXT TO PV BREAKER 29.04A SUB PANEL 5 6JUNCTION BOX METER MAIN SERVICE PANEL1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 735835835 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE PRODUCTION METER WHEN APPLICABLE RATED FREQUENCY: PHASES: RATING (kW or kVA): AVAILABLE FAULT CURRENT (AT OUTPUT TERMINALS): MAXIMUM OUTPUT AND INPUT CURRENT (AT OUTPUT TERMINALS): MAXIMUM OUTPUT AND INPUT VOLTAGE (AT OUTPUT TERMINALS): UTILITY-INTERACTIVE CAPABLE: FRANKLIN aPOWER X 60 Hz L1 / L2 / N / PE 5kW 20kA 24.5A 240V YES ENERGY STORAGE SYSTEM DISCONNECT CAUTION THIS PANEL HAS SPLICED FEED- THROUGH CONDUCTORS. LOCATION OF DISCONNECT AT ENERGY STORAGE BACK UP LOAD PANEL. [312.8(A)(3)] PLACE ON MAIN PANEL IF POINT OF INTERCONNECTION IS SUPPLY SIDE CAUTION DO NOT ADD NEW LOADS BACKUP LOAD CENTER [NEC 408.4] PLACE ON BACKUP LOAD CENTER CAUTION TRI POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHT PLACE ON MAIN PANEL IF ESS IS IN LINE OF SIGHT ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL PLACE ON MAIN PANEL IF ESS IS ON ADJACENT WALL ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALL PLACE ON MAIN PANEL IF ESS IS ON OPPOSITE WALL ADDITIONAL PLACARDS FOR ENERGY STORAGE SYSTEM PLACE ON ACCESSIBLE ESS DISCONNECT ONLY 1 REQUIRED [NEC 220] PLACE ON BACKUP LOAD CENTER [705.12(D)(3)] PLACE ON MAIN PANEL IF PV SYSTEM IS ALSO CONNECTED TO PANEL This item has been digitally signed and sealed on 03/31/26 Oct 10, 2024 1902 W Monica Ln 12/2/2024 SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION FOR (E) MAIN SERVICE PANEL JOSE LUIS MELGOZA 1902 MONICA LN, SANTA ANA, CA 92706 (E) BUS BAR:200 A (E) MAIN BREAKER:200 A MINIMUM SERVICE SIZE:87.3 A 1 GENERAL LIGHTING LOADS - 220-16(A)/ (B) R-3 DWELLING 1624 SQ. FT X 3 VA =4872 VA SMALL APPLIANCE LOADS - 1500 VA X 2 CKTS =3000 VA LAUNDRY LOAD - 1500 VA X 1 CKTS =1500 VA GENERAL LIGHTING TOTAL 9372 VA 2 COOKING EQUIPMENT LOADS - 220.55 (NAMEPLATE VALUE) RANGE @ 0 AMPS X 240 VOLTS =0 VA COOKTOP @ 0 AMPS X 240 VOLTS =0 VA OVEN @ 0 AMPS X 240 VOLTS =0 VA COOKING EQUIPMENT TOTAL 0 VA 3 ELECTRIC DRYER - 220.54 (NAMEPLATE, 5000 VA MINIMUM) DRYER @ 0 QTY 0 VA DRYER TOTAL 0 VA 4 HEATING & COOLING LOADS - 220.82(C) A/C 1 @ 50 AMPS X 240 VOLTS =9000.00 0000 VA A/C 2 @ 0 AMPS X 240 VOLTS =0 VA FURNACE 1 @ 0 AMPS X 240 VOLTS =0 VA FURNACE 2 @ 0 AMPS X 240 VOLTS =0 VA HEATING & COOLING TOTAL 9000 VA 5 EV CHARGER LOADS - 625.41 EV CHARGER 1 @ 0 AMPS X 240 VOLTS =0 VA EV CHARGER 2 @ 0 AMPS X 240 VOLTS =0 VA EV CHARGING TOTAL 0 VA 6 OTHER LOADS - NAMEPLATE DISPOSAL @ 1 QTY 900 VA DISHWASHER @ 1 QTY 1200 VA MICROWAVE @ 1 QTY 1600 VA REFRIDGERATOR @ 1 QTY 1800 VA OTHER LOADS - AS PER BREAKER SIZE POOL @ 0 AMPS X 240 VOLTS =0 VA SPA @ 0 AMPS X 240 VOLTS =0 VA FAU @ 0 AMPS X 240 VOLTS =0 VA WATER HEATER @ 0 AMPS X 240 VOLTS =0 VA GARAGE @ 0 AMPS X 240 VOLTS =0 VA WELDER @ 0 AMPS X 240 VOLTS =0 VA RV @ 0 AMPS X 240 VOLTS =0 VA FIXED APPLIANCE TOTAL 5500 VA SUBTOTAL 14872 VA 8 FIRST 10,000 VA @ 100%10000 VA REMAINING LOADS @ 4872 VA 40%1948.8 VA HEATING/COOLING @ 9000 VA 100%9000 VA EV CHARGING @ 0 VA 100%0 VA 9 TOTAL LOAD 20948.8 VA 10 MINIMUM SERVICE SIZE = TOTAL LOAD IN VA / 240 V 87.3 A DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: ELEC LOAD CALCS 010 EL1 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 JURISDICTION STAMPS 1902 W Monica Ln 12/2/2024 DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: 5 13 6 14 7 15 8 16 OPTIMIZER MAP 008 OM1 22 23 24 30 31 32 37 38 39 45 46 47 53 54 55 60 61 62 63 68 69 70 71 21 29 36 44 52 BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 1 9 2 10 3 11 4 12 18 19 20 26 27 28 33 34 35 41 42 43 49 50 51 56 57 58 59 64 65 66 67 17 25 40 48 INSTALLER NOTES: 72 1902 W Monica Ln 12/2/2024 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend. NEAREST MEDICAL FACILITY: NAME: PHONE: ADDRESS: PVC TRENCH DESIGNER: TAYLOR BICKFORD NEW PV SYSTEM: 9600W DC / 6960W AC Jose Luis Melgoza 1902 Monica Ln, Santa Ana, CA 92706 APN: 10104209 DATE: 10/4/2024 TIME: 09:43 AM DRAWING TITLE: DRAWING PAGE: SCALE:DESIGNER SIGNATURE: JOB HAZARD ANALYSIS 009 JH1 CREW LEAD: CREW: ELECTRICAL ZONE INSTALLER NOTES: BETTER EARTH ELECTRIC INC. 16720 MARQUARDT AVE CERRITOS CERRITOS, CA 90703 PHONE #: (888) 373-9379 LIC #: C10-1024460 TEMPLATE VERSION: B84 (E ) D R I V E W A Y (E) ENTRANCE 1902 W Monica Ln 12/2/2024 1902 W Monica Ln 12/2/2024 1902 W Monica Ln 12/2/2024 Engineering Alliance, Inc https://www.eng-alliance.com 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757 08-February-2023 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87101 Tel: 505 242 6411 Attn.: Engineering Department Subject: Engineering Certification for the Unirac SOLARMOUNT Flush Rail System to Support Photovoltaic Panels. The Unirac SOLARMOUNT Flush-to-Roof is an extruded aluminum rail system that is engineered to hold most framed solar modules to a roof structure and installed parallel to the roof. We have reviewed the SOLARMOUNT system, a proprietary mounting system constructed from modular parts which are intended for rooftop installation of solar photovoltaic (PV) panels; and have reviewed the U-Builder 2.0 Online tool. This U- Builder 2.0 software includes analysis for the SOLARMOUNT rails (SM LIGHT rail, SM STANDARD rail, and SM HEAVY DUTY rail) with Standard, Universal AF, and Pro Series hardware. All information, data, and analysis are in compliance with the following codes, city ordinances, and typical specifications: Codes: 1. 2019 & 2022 California Building Code, by California Building Standards Commission. 2. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures. 3. International Building Code, 2018 & 2021 Edition w/ Provisions from SEAOC PV-2 2017. 4. International Residential Code, 2018 & 2021 Edition w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. Aluminum Design Manual, 2015 & 2020 Edition. Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment: Shingle Roof: L-Foot, Flashkit Pro, Flashloc Comp, Flashloc Duo, Flashkit Pro SB Metal Roof: Standing Seam attachments, PM-9000S, PM Adjust Slotted Tile Roofs: Solar Hooks, Tile Replacement Attachment Spacing: Per U-Builder 2.0 Engineering report. Cantilever: The maximum cantilever length is L/3, where “L” is the span noted in the U-Builder 2.0 online tool. Clearance: 2” to 10” clear from top of roof to top of PV panel Tolerance(s): 1.0” tolerance for any specified dimension in this report is allowed for installation 1902 W Monica Ln 12/2/2024 Engineering Alliance, Inc https://www.eng-alliance.com 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757 Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE/SEI7-16 Component and Cladding design. Notes: 1. U-Builder 2.0 Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems and do not include roof capacity check. 2. Risk Category II per ASCE 7-16. 3. Topographic factor, kzt is 1.0. 4. Array Edge Factor ƳE = 1.5 5. Average parapet height is 0.0 ft. 6. Wind speeds are LRFD values. 7. Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder 2.0 design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-Builder 2.0 software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder 2.0 Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder 2.0 software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder 2.0 engineering report and the manufacturer specifications are in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. Please feel free to call for any questions or clarifications. Prepared By: Engineering Alliance, Inc Sugar Land, TX Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the short side. 08-FEB-2023 1902 W Monica Ln 12/2/2024 Date_____________ To Whom it May Concern, I ______________________________ , the owner of the property located at, Property Owner Name ADDRESS:_________________________________________ I Have hired,Better Earth Electric Inc,State Lic #1024460,to install a PV Solar System: __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ Kind Regards , ________________________________ Signature ________________________________ Print Name Better Earth Electric Inc. 1815 E Wilshire Ave. St., 908/909, Santa Ana CA 92705 888-373-9379 SantaAnaPermits@Betterearth.solar Jose Luis Melgoza 1902 Monica Ln Santa Ana, CA 92706 9.6kw with 1 battery storage with 24 modules 2024-11-14 Jose Luis Melgoza Document Ref: LHAKR-FVTTS-J55CX-UYHYD Page 1 of 1 1902 W Monica Ln 12/2/2024 Signature Certificate Reference number: LHAKR-FVTTS-J55CX-UYHYD Document completed by all parties on: 15 Nov 2024 04:57:29 UTC Page 1 of 1 Signer Timestamp Signature Jose Luis Melgoza Email: jesusmelgoza1221@gmail.com Recipient Verification: Sent:07 Nov 2024 18:21:52 UTC Viewed:15 Nov 2024 04:53:21 UTC Signed:15 Nov 2024 04:57:29 UTC ✔Email verified 15 Nov 2024 04:53:21 UTC IP address: 98.147.214.142 Location: Santa Ana, United States Signed with PandaDoc PandaDoc is a document workflow and certified eSignature solution trusted by 50,000+ companies worldwide. 1902 W Monica Ln 12/2/2024 Digitally sealed by RJM on Date: Job #:24‐07023 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566‐0066 Email: SE@mcpe.group 10/7/24 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Melgoza Residence 1902 Monica Ln Santa Ana, CA 92706 10/7/24 Designed in Accordance with CBC 2022, ASCE 7‐16 10/7/2024 10:20 AM 1 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On‐site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre‐engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or discrepancies between current condition of the structure or otherwise as this letter describes before proceeding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 10/7/2024 10:20 AM 2 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Location: 1902 Monica Ln Santa Ana, CA 92706 Existing Structure Info: Number of Stories = 1 Aroof =2900 sq. ft.Roof Square Footage A3rd_flr =0 sq. ft.Third Floor Square Footage (if applicable) A2nd_flr =0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Latitude = Longitude = Ss = 1.334 S1 = 0.474 Exposure Category = C Ult. Wind Speed = 100 m.p.h. P.V. Array Info: Model = LR5‐54HABB‐400M Height of Panel = 67.79 in. Width of Panel = 44.64 in. Area of Panel = 21.0 ft.2 Number of New Panels = 24 Number of Exis. Panels = 0 Total Area of Array = 504.4 ft.2 Spacing of Anchors =4.00 ft. max. on cente rows of racks per panel =2 Panel Tilt = 7‐27 deg 33.767804 ‐117.895432 Project Info 10/7/2024 10:20 AM 3 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x6 Rafters Misc = 1.0 p.s.f. DLr1 =8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f.Drywall and framing DLr2 =10.0 p.s.f.Total Existing Roof Dead Load LLr = 20.0 p.s.f.Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels = 2.9 p.s.f.weight of panels including rack system DLr1_proposed =10.9 p.s.f.Proposed Roof Dead Load (applied to top only) DLr2_proposed =12.9 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) =81.2 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) =72.6 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - W ex =‐10.65% TOTAL DECREASE IN GRAVITY LOADS, PANELS OK!Wex 10/7/2024 10:20 AM 4 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Seismic Design Parameters Risk Category = 2 Per Table 1‐5‐1 R = 6.5 Response Modification Factor (Table 12‐2.1) Site Class = D Per 11.4.2 Ie =1 Seismic Importance Factor (Table 1.5‐2) Ss =1.33 Short Period P.G.A. S1 =0.47 1‐Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa =1.20 Site Coefficient per Table 11.4‐1 ASCE 7‐16 Supplement #1 Tables used for Fa and Fv Fv =1.70 Site Coefficient per Table 11.4‐2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa =1.60 Short Period M.C.E. Per Eq. 11.4‐1 SM1 = SD1 Fv =0.81 1‐Sec Period M.C.E. Per Eq. 11.4‐2 SDS = 2/3 (SMS) =1.07 Short Period Design Parameter Per Eq 11.4‐3 SD1 = 2/3 (SM1) =0.54 1‐Sec Period Design Parameter Per Eq 11.4‐4 Approximate Fundamental Period (Per 12.8.2.1 per Eq. 12.8‐7 hn = 15 ft Ct =0.02 (per table 12.8‐2) x = 0.75 (per table 12.8‐2) T = 0.15 sec Approximate Fundamental Period TL =8 sec Long‐Period Transition Period per Figure 22‐12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8‐2 Cs1 = 1.5*(SD1 Ie)/R T = 0.81 Max. Seismic Response Coefficient Per Eq. 12.8‐3 if T ≤ TL Cs2 =0.01 Min. Seismic Response Coefficient Per Eq. 12.8‐5 Cs2 = 0.044 SDS Ie =0.05 Min. Seismic Response Coefficient Per Eq. 12.8‐5 Cs3 = 0.5 S1 Ie/R =0.04 Min. Seismic Response Coefficient Per Eq. 12.8‐6 if S 1 ≥ 0.6g CS =0.16 Design Seismic Coefficient Check Additional Base Shea Wexisting =29.0 kips Weight of Existing Structure Wpanels =1.4 kips Weight of Proposed Panels Vexisting = Cs W existing =4.8 kips Roof Level Shear of Existing Structure Vpanels = Cs W panels =0.2 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn)x = 4.97% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 10/7/2024 10:20 AM 5 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7‐16) Vult =100 mph Kzt =1.00 (sec 26.8.2)h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd =0.85 (sec 26.6) Roof θ = 7‐27 deg Ke =1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V2 qh =18.50 (eq. 26.10‐1) GPp =‐2 uplift γE =1.5 (sec 29.4.4) γa =0.78 (fig 29.4‐8) γE =1.5 FIG 29.4‐7)γc =0.94 (fig 29.4‐7)hpt =0 γa =0.78 (fig 29.4‐8)γp =0.9 (fig 29.4‐7)ω =0.00 deg (panel tilt) GPp =‐2 uplift GCrm =1.4 uplift p = qh (GPp) γE γa (eq 29.4‐7)p = qh (GCrn) γE γC γp (eq 29.4‐6) p =‐43.2 p.s.f.p =32.8 p.s.f. Check Anchorage to Existing Structur 0.6DL ‐ 0.6W controlling load combination (eq. 16‐15 for ASD) DL = 2.9 p.s.f.dead load of panel (including rack system) W = 43.2 p.s.f.wind load normal to face of panel Arealag =11.3 sq. ft.area tributary to each anchor SPanc =4.00 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) =273.6 lbs.total uplift on anchor Material = DFL lumber anchor material Dialag =5/16 in.diameter of screw Penlag = 2.5 in.min. penetration to existing framing W lag =266 lb/in.withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews =1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews =851.2 lbs.total allowable withdrawal on anchor Puplift Pallow Anchorage =USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels ‐ ASCE Section 29.4.4 (where applicable) Flat Roof Panels ‐ ASCE Section 29.4.3 (where applicable) =0.32 < 1.00 Anchor is OK! 10/7/2024 10:20 AM 6 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Gravity Loads: DEMAND DECREASED BY 10.65% = OK! Lateral Loads: DEMAND INCREASED BY 4.97% < 10% = OK! Anchorage: DEMAND OF 273.6LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRA ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 10/7/2024 10:20 AM 7 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 Digitally sealed by RJM on Date: Job #:24‐07023 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566‐0066 Email: SE@mcpe.group 10/7/24 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Melgoza Residence 1902 Monica Ln Santa Ana, CA 92706 10/7/24 Designed in Accordance with CBC 2022, ASCE 7‐16 10/7/2024 10:20 AM 1 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents *Note: This engineering report is limited to the information presented to Engineer via plans, site information, photos, and written correspondence as provided by Client. On‐site structural observations and verification of site conditions are not included herein. Engineering for manufactured products such as photovoltaic modules or racking systems is excluded from this report. Please refer to the manufacturer's specifications, certifications, and pre‐engineered packages for product engineering. Installations of solar modules and related equipment must be performed in accordance with manufacturer recommendations, local codes, local regulations, industry best practices, and applicable safety standards. Owner and/or Contractor shall notify Engineer should any damage, deterioration, or discrepancies between current condition of the structure or otherwise as this letter describes before proceeding with construction. This letter applies only to regions of the structure where solar modules will be supported and the supporting elements. 10/7/2024 10:20 AM 2 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Location: 1902 Monica Ln Santa Ana, CA 92706 Existing Structure Info: Number of Stories = 1 Aroof =2900 sq. ft.Roof Square Footage A3rd_flr =0 sq. ft.Third Floor Square Footage (if applicable) A2nd_flr =0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Latitude = Longitude = Ss = 1.334 S1 = 0.474 Exposure Category = C Ult. Wind Speed = 100 m.p.h. P.V. Array Info: Model = LR5‐54HABB‐400M Height of Panel = 67.79 in. Width of Panel = 44.64 in. Area of Panel = 21.0 ft.2 Number of New Panels = 24 Number of Exis. Panels = 0 Total Area of Array = 504.4 ft.2 Spacing of Anchors =4.00 ft. max. on cente rows of racks per panel =2 Panel Tilt = 7‐27 deg 33.767804 ‐117.895432 Project Info 10/7/2024 10:20 AM 3 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x6 Rafters Misc = 1.0 p.s.f. DLr1 =8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f.Drywall and framing DLr2 =10.0 p.s.f.Total Existing Roof Dead Load LLr = 20.0 p.s.f.Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels = 2.9 p.s.f.weight of panels including rack system DLr1_proposed =10.9 p.s.f.Proposed Roof Dead Load (applied to top only) DLr2_proposed =12.9 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) =81.2 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) =72.6 kips Proposed Load Demand Gravity Loads Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Wprop - W ex =‐10.65% TOTAL DECREASE IN GRAVITY LOADS, PANELS OK!Wex 10/7/2024 10:20 AM 4 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Seismic Design Parameters Risk Category = 2 Per Table 1‐5‐1 R = 6.5 Response Modification Factor (Table 12‐2.1) Site Class = D Per 11.4.2 Ie =1 Seismic Importance Factor (Table 1.5‐2) Ss =1.33 Short Period P.G.A. S1 =0.47 1‐Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa =1.20 Site Coefficient per Table 11.4‐1 ASCE 7‐16 Supplement #1 Tables used for Fa and Fv Fv =1.70 Site Coefficient per Table 11.4‐2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa =1.60 Short Period M.C.E. Per Eq. 11.4‐1 SM1 = SD1 Fv =0.81 1‐Sec Period M.C.E. Per Eq. 11.4‐2 SDS = 2/3 (SMS) =1.07 Short Period Design Parameter Per Eq 11.4‐3 SD1 = 2/3 (SM1) =0.54 1‐Sec Period Design Parameter Per Eq 11.4‐4 Approximate Fundamental Period (Per 12.8.2.1 per Eq. 12.8‐7 hn = 15 ft Ct =0.02 (per table 12.8‐2) x = 0.75 (per table 12.8‐2) T = 0.15 sec Approximate Fundamental Period TL =8 sec Long‐Period Transition Period per Figure 22‐12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8‐2 Cs1 = 1.5*(SD1 Ie)/R T = 0.81 Max. Seismic Response Coefficient Per Eq. 12.8‐3 if T ≤ TL Cs2 =0.01 Min. Seismic Response Coefficient Per Eq. 12.8‐5 Cs2 = 0.044 SDS Ie =0.05 Min. Seismic Response Coefficient Per Eq. 12.8‐5 Cs3 = 0.5 S1 Ie/R =0.04 Min. Seismic Response Coefficient Per Eq. 12.8‐6 if S 1 ≥ 0.6g CS =0.16 Design Seismic Coefficient Check Additional Base Shea Wexisting =29.0 kips Weight of Existing Structure Wpanels =1.4 kips Weight of Proposed Panels Vexisting = Cs W existing =4.8 kips Roof Level Shear of Existing Structure Vpanels = Cs W panels =0.2 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn)x = 4.97% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 10/7/2024 10:20 AM 5 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7‐16) Vult =100 mph Kzt =1.00 (sec 26.8.2)h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd =0.85 (sec 26.6) Roof θ = 7‐27 deg Ke =1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V2 qh =18.50 (eq. 26.10‐1) GPp =‐2 uplift γE =1.5 (sec 29.4.4) γa =0.78 (fig 29.4‐8) γE =1.5 FIG 29.4‐7)γc =0.94 (fig 29.4‐7)hpt =0 γa =0.78 (fig 29.4‐8)γp =0.9 (fig 29.4‐7)ω =0.00 deg (panel tilt) GPp =‐2 uplift GCrm =1.4 uplift p = qh (GPp) γE γa (eq 29.4‐7)p = qh (GCrn) γE γC γp (eq 29.4‐6) p =‐43.2 p.s.f.p =32.8 p.s.f. Check Anchorage to Existing Structur 0.6DL ‐ 0.6W controlling load combination (eq. 16‐15 for ASD) DL = 2.9 p.s.f.dead load of panel (including rack system) W = 43.2 p.s.f.wind load normal to face of panel Arealag =11.3 sq. ft.area tributary to each anchor SPanc =4.00 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) =273.6 lbs.total uplift on anchor Material = DFL lumber anchor material Dialag =5/16 in.diameter of screw Penlag = 2.5 in.min. penetration to existing framing W lag =266 lb/in.withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews =1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews =851.2 lbs.total allowable withdrawal on anchor Puplift Pallow Anchorage =USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Wind Uplift Anchorage Flush Mounted Panels ‐ ASCE Section 29.4.4 (where applicable) Flat Roof Panels ‐ ASCE Section 29.4.3 (where applicable) =0.32 < 1.00 Anchor is OK! 10/7/2024 10:20 AM 6 of 7 ©McPherson Engineering 1902 W Monica Ln 12/2/2024 By: J.R. Date: 10/7/24 Gravity Loads: DEMAND DECREASED BY 10.65% = OK! Lateral Loads: DEMAND INCREASED BY 4.97% < 10% = OK! Anchorage: DEMAND OF 273.6LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRA ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 10/7/2024 10:20 AM 7 of 7 ©McPherson Engineering 1902 W Monica Ln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pNN 8JEUIpNN .PEVMF5ZQF 5FTUJOH$POEJUJPO .BYJNVN1PXFS 1NBY8 0QFO$JSDVJU7PMUBHF 7PD7 4IPSU$JSDVJU$VSSFOU *TD" 7PMUBHFBU.BYJNVN1PXFS 7NQ7 $VSSFOUBU.BYJNVN1PXFS *NQ" .PEVMF&DJFODZ &MFDUSJDBM$IBSBDUFSJTUJDT45$".8N˫/0$5".8N˫NT5FTUVODFSUBJOUZGPS1NBYp 45$ /0$5 -3)"##. 45$ /0$5 -3)"##. 45$ /0$5 -3)"##. 45$ /0$5 -3)"##. .FDIBOJDBM-PBEJOH 'SPOU4JEF.BYJNVN4UBUJD-PBEJOH 1B 3FBS4JEF.BYJNVN4UBUJD-PBEJOH 1B )BJMTUPOF5FTU NN)BJMTUPOFBUUIFTQFFEPGNT 5FNQFSBUVSF3BUJOHT 45$ 5FNQFSBUVSF$PFDJFOUPG*TD ˫ 5FNQFSBUVSF$PFDJFOUPG7PD ˫ 5FNQFSBUVSF$PFDJFOUPG1NBY ˫ 0QFSBUJOH1BSBNFUFST 0QFSBUJPOBM5FNQFSBUVSF ˫_˫ 1PXFS0VUQVU5PMFSBODF _ .BYJNVN4ZTUFN7PMUBHF %$7 *&$6- .BYJNVN4FSJFT'VTF3BUJOH " /PNJOBM0QFSBUJOH$FMM5FNQFSBUVSF p˫ 1SPUFDUJPO$MBTT $MBTT** #JGBDJBMJUZ p 6-UZQF *&$$MBTT$ 'JSF3BUJOH &MFDUSJDBMDIBSBDUFSJTUJDTXJUIEJFSFOUSFBSTJEFQPXFSHBJO SFGFSFODFUP8GSPOU 1NBY8 7PD7 *TD" 7NQ7 *NQ" 1NBYHBJO 45$ /0$5 -3)"##. 4QFDJDBUJPOTJODMVEFEJOUIJTEBUBTIFFUBSF TVCKFDUUPDIBOHFXJUIPVUOPUJDF-0/(J SFTFSWFTUIFSJHIUPGOBMJOUFSQSFUBUJPO 7%( 45$ /0$5 -3)"##. .FDIBOJDBM1BSBNFUFST $FMM0SJFOUBUJPO +VODUJPO#PY *1 (MBTT %VBMHMBTT NN4FNJUFNQFSFEHMBTT 'SBNF "OPEJ[FEBMVNJOVNBMMPZGSBNF 8FJHIU LH %JNFOTJPO NN &70$POOFDUPS5ZQF 1BDLBHJOH NN pNN MFOHUIDBOCFDVTUPNJ[FE QDTQFSQBMMFUQDTQFS(1 QDT QDT POMZGPS64" QFS)$ 0VUQVU$BCMF :FBS1PXFS8BSSBOUZ 1902 W Monica Ln 12/2/2024 IQ8SP-12A-DSH-00207-3.0-EN-US-2024-02-12 DATA SHEET IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built using advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Compliant with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Microinverters cannot be mixed with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative according to the IEEE 1547 interconnection standard. An IQ Gateway is required to make these changes during installation. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. **IQ8 and IQ8+ support split-phase, 240 V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-and-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations, when installed according to the manufacturer’s instructions. IQ8SP-12A-DSH-00207-3.0-EN-US-2024-02-12 (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. INPUT DATA (DC)UNITS IQ8-60-2-US IQ8 PLUS -72-2-US Commonly used module pairings1 W 235–350 235–440 Module compatibility —To meet compatibility, PV modules must be within maximum input DC voltage and maximum module Isc listed below. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 27–37 27–45 Operating range V 16–48 16–58 Minimum/Maximum start voltage V 22/48 22/58 Maximum input DC voltage V 50 60 Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum module (Isc) A 20 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires maximum 20 A per branch circuit. OUTPUT DATA (AC)UNITS IQ8-60-2-US IQ8 PLUS -72-2-US Peak output power VA 245 300 Maximum continuous output power VA 240 290 Nominal grid voltage (L-L)V 240, split-phase (L-L), 180° Minimum and Maximum grid voltage2 V 211-264 Maximum continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short-circuit fault current over three cycles Arms 2 Maximum units per 20 A (L-L) branch circuit3 —16 13 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 30 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading … 0.85 lagging Peak efficiency %97.7 CEC weighted efficiency %97 Nighttime power consumption mW 23 25 MECHANICAL DATA Ambient temperature range -40°C to 60°C (-40°F to 140°F) Relative humidity range 4% to 100% (condensing) DC connector type MC4 Dimensions (H × W × D)212 mm (8.3 in) × 175 mm (6.9 in) × 30.2 mm (1.2 in) Weight 1.08 kg (2.38 lbs) Cooling Natural convection–no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/Outdoor IQ8 and IQ8+ Microinverters 1902 W Monica Ln 12/2/2024 IQ8SP-12A-DSH-00207-3.0-EN-US-2024-02-12 COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV Systems, for AC and DC conductors, when installed according to the manufacturer’s instructions. REVISION DATE DESCRIPTION DSH-00207-3.0 February 2024 Updated the information about IEEE 1547 interconnection standard requirements. DSH-00207-2.0 October 2023 Included NEC 2023 specification in the “Compliance” section. DSH-00207-1.0 September 2023 Updated module compatibility specification. 1902 W Monica Ln 12/2/2024 © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change.IQC-5-5C-DSH-00007-4.0-EN-US-2024-06-13 IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre-wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. The IQ Combiner 5/5C, IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. 5-year limited warranty Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect (CELLMODEM-M1-06-SP-05), only with IQ Combiner 5C • Supports flexible networking: Wi-Fi, Ethernet, or cellular • Provides production metering (revenue grade) and consumption monitoring Easy to install • Mounts to one stud with centered brackets • Supports bottom, back, and side conduit entries • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV branch circuits • Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Reliable • Durable NRTL-certified NEMA type 3R enclosure • 5-year limited warranty • 2-year labor reimbursement program coverage included for both the IQ Combiner SKUs* • UL1741 Listed X-IQ-AM1-240-5 X-IQ-AM1-240-5C IQ Battery 5P Fully integrated AC battery system. Includes six field-replaceable IQ8D-BAT Microinverters. IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) simplify the installation process. IQ System Controller 3/3G Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. . IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. DATA SHEET *For country-specific warranty information, see the https://enphase.com/installers/resources/warranty page. IQC-5-5C-DSH-00007-4.0-EN-US-2024-06-13IQC-5-5C-DSH-00007-4.0-EN-US-2024-06-13 IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 (X-IQ-AM1-240-5) IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSIC12.20 ±0.5%), consumption monitoring (±2.5%), and IQ Battery monitoring (±2.5%). Includes a silver solar shield to deflect heat. IQ Combiner 5C (X-IQ-AM1-240-5C) IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%), consumption monitoring (±2.5%) and IQ Battery monitoring (±2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)¹. Includes a silver solar shield to deflect heat. WHAT’S IN THE BOX IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System Busbar 80 A busbar with support for one IQ Gateway breaker and four 20 A breaker for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Pre-wired revenue-grade solid-core CT, accurate up to ±0.5% Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to ±2.5% IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to ±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Enphase Mobile Connect (only with IQ Combiner 5C)4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for the COMMS-KIT-02 board ACCESSORIES AND REPLACEMENT PARTS (N OT INCLUDED, ORDER SEPARATELY) CELLMODEM-M1-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan CELLMODEM-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan Circuit breakers (off-the-shelf) Supports Eaton BR2XX, Siemens Q2XX and GE/ABB THQL21XX Series circuit breakers (XX represents 10, 15, 20, 30, 40, 50, or 60). Also supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with the hold-down kit. Circuit breakers (provided by Enphase)BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P- 240V-B (more details in the “Accessories” section) XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 5/5C X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws) XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board (PCB) for IQ Combiner 5/5C ELECTRICAL SPECIFICATIONS Rating 80 A System voltage and frequency 120/240 VAC, 60 Hz Busbar rating 125 A Fault current rating 10 kAIC Maximum continuous current rating (input from PV/storage) 64 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers only (not included) Maximum total branch circuit breaker rating (input) 80 A of distributed generation/95 A with IQ Gateway breaker included IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering, included with the box 1 A plug-and-play industrial-grade cell modem for systems of up to 60 microinverters. Available in the United States, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area. 1902 W Monica Ln 12/2/2024 MECHANICAL DATA Dimensions (W × H × D)37.5 cm × 49.5 cm × 16.8 cm (14.75" × 19.5" × 6.63"). Height is 53.5 cm (21.06”) with mounting brackets. Weight 7.5 kg (16.5 lb) Ambient temperature range -40°C to 46°C (-40°F to 115°F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing Communication (in-premise connectivity)Built-in CTRL board for wired communication with the IQ Battery 5P and the IQ System Controller 3/3G. Integrated power line communication for IQ Series Microinverters. Altitude Up to 2,600 meters (8,530 feet) COMMUNICATION INTERFACES Integrated Wi-Fi 802.11b/g/n (dual band 2.4 GHz/5 GHz) for connecting the Enphase Cloud through the internet. Wi-Fi range (recommended) 10 m (32.8 feet) Bluetooth BLE4.2, 10 m range to configure Wi-Fi SSID Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) for connecting to the Enphase Cloud through the internet. Cellular/Mobile Connect CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-AT-05 (included with the IQ Combiner 5C) Digital I/O Digital input/output for grid operator control USB 2.0 Mobile Connect, COMMS-KIT-01 for IQ Battery 3/3T/10/10T, COMMS-KIT-02 for IQ Battery 5P Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication 90–110 kHz Web API See https://developer-v4.enphase.com Local API See Guide for local API at https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication COMPLIANCE IQ Combiner with IQ Gateway UL 1741, CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016, UL 60601-1/CANCSA 22.2 No. 61010-1, IEEE 1547: 2018 (UL 1741-SB, 3rd Ed.), IEEE 2030.5/CSIP Compliant, Production metering: ANSI C12.20 accuracy class 0.5 (PV production) COMPATIBILITY PV Microinverters IQ6, IQ7, and IQ8 Series Microinverters COMMS-KIT-01 2 IQ System Controller EP200G101-M240US00 IQ System Controller 2 EP200G101-M240US01 IQ Battery ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA COMMS-KIT-02 3 IQ System Controller 3 SC200D111C240US01, SC200G111C240US01 IQ Battery IQBATTERY-5P-1P-NA 2 For information about IQ Combiner 5/5C compatibility with the 2nd-generation batteries, refer to the compatibility matrix at https://enphase.com/download/compatibility-matrix. 3 IQ Combiner 5/5C comes pre-equipped with COMMS-KIT-02. IQC-5-5C-DSH-00007-4.0-EN-US-2024-06-13 Mobile Connect 4G-based LTE-M1 cellular modem with a 5-year data plan (CELLMODEM-M1-06-SP-05 for Sprint and CELLMODEM-M1-06-AT-05 for AT&T) Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole, 15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-SOLID 200 A revenue-grade solid core Production CT with <0.5% error rate (replacement SKU) CT-200-CLAMP 200 A clamp-style consumption and battery metering CT with <2.5% error rate (replacement SKU) 1902 W Monica Ln 12/2/2024 Revision history REVISION DATE DESCRIPTION DSH-00007-4.0 June 2024 Updated the UL smart mark. DSH-00007-3.0 March 2024 Updated accessories and replacement parts, communication interfaces, and compatibility specifications. DSH-00007-2.0 September 2023 Included Bluetooth specifications. DSH-00007-1.0 May 2023 Initial release. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change.IQC-5-5C-DSH-00007-4.0-EN-US-2024-06-13 1902 W Monica Ln 12/2/2024 Micro-grid interconnect device (MID) Integrated PV and grid metering Auto load-shedding Compatible with micro and string solar inverter Optional Smart-Circuits Module Optional Generator Module Coupling Nominal AC Voltage Phase aPower Over Current Protection Device Solar Input Over Current Protection Device Backup Load Port Over Current Protection Device Generator Over Current Protection Device1 Maximum Supply Fault Current Busbar Rating Smart Circuits Over Current Protection Device2 Work Modes Communications User Interface Warranty AC-coupled 120 / 208 V, 120 / 240 V, 60 Hz 2 W+N+PE 100 A Max 80 A Max Self-Consumption, Time of Use, Emergency Backup Ethernet / 4G / Wifi FranklinWH App 12 years 20 kA 280 A Opt. a 1 × 80 A Max @ 208 V / 240 V & 1 × 50 A Max @ 208 V / 240 V Opt. b 1 × 80 A Max @ 208 V / 240 V & 2 × 50 A Max @ 120 V Certifications Seismic Environmental Emissions UL 17413, UL 1741 PCS3, UL 673, UL 869A3, UL 9163, CAN/CSA C22.2 No. 107.1-16, CSA C22.2 No. 29, CSA C22.2 No. 0.19 AC 156, OSHPD, IEEE 693-2005 (high) California Proposition 65 RoHS Directive 2011 / EU FCC Part 15 Class B, ICES 003 Dimensions (H × W × D) Weight Mounting 31.5 in × 21.7 in × 6.3 in (800 mm × 550 mm × 160 mm) 50 lb (23 kg) Wall mount or floor mount Enclosure Type Operating Temperature Operating Humidity (RH) Altitude Environment NEMA 3R -4°F to 122°F (-20°C to 50°C) Up to 100% RH, condensing Maximum 9,843 ft (3,000 m) Indoor and outdoor rated 1. Generator Module is optional. 2. Smart Circuit Module is optional. 3. Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. 200 A Max 200 A Max 31.5 in (800 mm) 31.5 in (800 mm) 21.7 in (550 mm) 21.7 in (550 mm) 6.3 in (160 mm) 6.3 in (160 mm) Serves as the controller for all home power sources by interconnecting solar, grid, batteries, and a standby generator to supply electricity to the home. Seamlessly transitions the home supply from grid power to backup power so that always-on appliances, such as the refrigerator and network router, will not be affected when grid goes down. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS W W W . F R A N K L I N W H . C O M aGate Intelligent energy management system W W W . F R A N K L I N W H . C O M Store solar generated power while the sun is shining. Use the stored energy when needed to lower electric bills. Run heavy loads such as air conditioners and water heaters as usual even during grid outages. Provide homeowner peace of mind by fully charging before severe weather events. aPower AC-coupled battery Safe LFP chemistry Built-in inverter 13.6 kWh per unit, up to 204 kWh (15 units) per aGate 5 kW continuous / 10 kW peak for 10s (discharge) Normal operations down to -4°F (-20°C) IP67 protection Single aPower capable of starting a 4-Ton AC First-of-its-kind 208 V compliant battery for multi-family housing Battery Chemistry Usable System Energy Aggregate Throughput Real Power (charge) Real Power (discharge) Load Start Capability Nominal AC Voltage Coupling Phase Round Trip Efficiency Noise Emission User Interface Warranty Work Modes Lithium Iron Phosphate (LFP) 13.6 kWh per unit, up to 15 units1 per aGate 43 MWh 5 kW continuous, 7.6 kW peak for 30 minutes 5 kW continuous, 10 kW peak for 10 seconds 118 A LRA2 120 / 208 V, 120 / 240 V, 60 Hz AC-coupled 2 W+N+PE 89%3 Self-Consumption, Time of Use, Emergency Backup ġ30 dB (A)4 FranklinWH App 12 years Certifications Seismic UL 9540, UL 9540A, UL 1741, UL 1973, IEEE 1547, IEEE 1547.1, UN 38.3,CAN/CSA C22.2 No. 107.1-16 AC 156, OSHPD, IEEE 693-2005 (high) California Proposition 65 RoHS Directive 2011 / EU FCC Part 15 Class B, ICES 003 Dimensions (H × W × D) Weight Mounting Cooling 45.3 in × 29.5 in × 11.4 in (1150 mm × 750 mm × 290 mm) 395 lb (179 kg) Wall mount or floor mount Natural air-cooled design PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS COMPLIANCE INFORMATION Ingress Protection Operating Temperature Operating Humidity (RH) Altitude Environment IP67 (Battery and power converter system), IP56 (Wiring compartment) -4°F to 122°F (-20°C to 50°C) Up to 100% RH, condensing Maximum 9,843 ft (3,000 m) Indoor and outdoor rated ENVIRONMENTAL SPECIFICATIONS 1. For 120 / 208V applications, max. 4 aPowers per aGate can be connected in parallel. Please contact us if you have large capacity requirements. 2. Load start capability may vary. 3. At beginning of life, AC to battery to AC, 50% power rating. 4. 5 kW discharge power, no fan running. 45.3 in (1150 mm) 45.3 in (1150 mm) 29.5 in (750 mm) 29.5 in (750 mm) 11.4 in (290 mm) 11.4 in (290 mm) ored h as air . ere Environmental Emissions 1902 W Monica Ln 12/2/2024 D ATA S H E E T W W W. F R A N K L I N W H . C O M Address:1731 Technology Dr., Suite 530 San Jose, CA 95110 Telephone: +1 888-837-2655 Email: info@franklinwh.com Website: www.franklinwh.com Copyright 2024 FranklinWH Energy Storage Inc. All rights reserved. The Franklin logo, FranklinWH, and other trademarks or service names are the trademarks of FranklinWH Energy Storage Inc. The document is for informational purposes only, data subject to change. 2024-02-29 Whole Home Backup Franklin Home Power Solution Partial Home Backup Main Panel Solar InverterSolar Panels Generator (Optional) Utility Meter Utility Grid aGate Smart Circuits (Optional) EV Charger Pool Pump Air Conditioner aPower FranklinWH App Backup Loads Solar InverterSolar Panels Generator (Optional) Utility Meter Utility Grid Non-backup Panel Non-essential Loads aGate Main PanelBackup Loads Smart Circuits (Optional) EV Charger Pool Pump Air Conditioner aPower FranklinWH App 1902 W Monica Ln 12/2/2024 FOR QUESTIONS OR CUSTOMER SERVICE CONTACT: 505-242-6411 | SALES@UNIRAC.COM | WWW.UNIRAC.COM PUB2024JAN01-V1 UL2703AUL2703CONFORMS TOCONFORMS TO • High strength, waterproof attachment. • No more lifting, prying or damaging shingles. • With an outer shield contour- conforming gasket, and pressurized sealant chamber the Triple Seal Technology delivers a 100% waterproof connection. • Simply drive the lag bolt and inject sealant into the port to create a permanent pressure seal. • Faster Installation in just 3 steps; pre-install, secure, and seal. PROTECT THE ROOF LOCK OUT WATER HIGH-SPEED INSTALLATION FLASHLOC™ COMP KIT Available in Dark and Mill WHY FLASHLOC™ COMP? FLASHLOC™ is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL Technology preserves the roof and protects the penetration with a permanent pressure seal. Don’t just divert water, LOC it out! KITTED WITH • TEN (10) Flashloc Attachments • TEN (10) Lag bolts with sealing washer Inject sealantinto the port to create permanent preassureseal Countour-conforminggasket Triple Seal Technology100% waterproof connection Pressurizedsealant chamber • T-Bolt rail attachment hardware • ONE (1) tube of approved Sealant R BETTER SOLAR STARTS HERE 1902 W Monica Ln 12/2/2024 UL2703CONFORMS TOFOR QUESTIONS OR CUSTOMER SERVICE CONTACT: 505-242-6411 | SALES@UNIRAC.COM | WWW.UNIRAC.COM PUB2024JAN01-V1 • Designed for Unirac’s Solarmount rail systems and certified to UL2703A for low- slope AND steep-slope roofs • One-step butyl application for easy install and reliable waterproofing FEATURING SOLARMOUNT • Universal AF mid clamps and end clamps adjust to module heights from 30-46mm in a great looking, easy to install fastener • Pro-series clamps feature hidden fasteners for fantastic aesthetics • Standard clamps feature tight row spacing and various clamps to accommodate module frames up to 51mm in height • Solarmount Standard and Solarmount Light rails profiles for installations across the country, including Puerto Rico • Huge selection of attachments for any roof form comp shingle to tile • Adjustable tilt legs certified to UL2703 to dial in your system just right DIFFERENT CLAMPS FOR DIFFERENT NEEDS OPTIONS FOR ANY APPLICATION SOLARMOUNT WHY SOLARMOUNT? SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with universal clamps, tons of attachment options, full system UL 2703 certification, and 25-year warranty. Sleek rails for both light and heavy duty applications, with optional trim, make for a reliable, cost-effective, great looking racking solution. OPTIONALFRONT TRIM Two rail profiles for light and heavy duty applications Components available in Mill and Dark finishes for any aesthetic and any budget SM PRO SERIESMID CLAMPUNIVERSAL MID CLAMP CONCEALED SM END CLAMPUNIVERSAL END CLAMP SOLARMOUNT BUTYL SOLARMOUNT PROFILEAND LIGHT PROFILE R BETTER SOLAR STARTS HERE 1902 W Monica Ln 12/2/2024 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PHOTOVOLTAIC BETTER EARTH ELECTRIC 1024460 C-10 1902 Monica Ln Santa Ana, CA 92706 Maria Orozco 323-523-7379 10/25/24 maria.o@betterearth.solar 1902 W Monica Ln 12/2/2024