Loading...
HomeMy WebLinkAbout2625 S Hickory St - PlanFLOOR LEVEL 8'-3"4' 8' 18' FLOOR LEVEL 8'-3" 16' 3' 3' 3' 4' 16' 2' 2' 3'-2" STORAGE RACK PLAN TITLE SHEET A1 SCALE: 3 = 1'-0" SCOPE OF WORK GOVERNING CODES 1 2022 CALIFORNIA BUILDING CODE 2 3 2022 NFPA 13 GENERAL BUILDING INFORMATION REQUIRED SPECIAL INSPECTION(S) 2022 CALIFORNIA FIRE CODE PLAN NOTES AND REVISIONS PR O J E C T N A M E PR O P H E T P R E M I U M B L E N D L L C 26 2 5 S . H I C K O R Y S T . SA N T A A N A , C A 9 2 7 0 7 1) I N I T I A L P L A N S U B M I T T A L 10 / 0 9 / 2 0 2 4 BUILDING OWNER TENENT CONTRACTOR ARCHITECT/ ENGINEER 6" CONCRETE S.O.G ELEVATION DETAILS: ASSESSOR PARCEL NUMBER: SPRINKLER BUILDING (Y / N): BUILDING CONSTRUCTION TYPE: OCCUPANCY GROUP: NUMBER OF STORIES: TOTAL WAREHOUSE AREA: SCOPE OF WORK AREA: CEILING SPRINKLER INFORMATION: CEILING ELEVATION: 414-101-13 NO III-B B, S -2 1 , SCOPE LIMITED TO WAREHOUSE ONLY 11,862 SF 7,700 SF NA 18' 1. DEPUTY INSPECTION TO BE COMPLETED FOR THE INSTALLED HILTI KBTZ-2 1 2" X 4.5" ANCHOR BOLTS RACK CAPACITIES AND HEIGHTS RACK TYPE MAX STORAGE HEIGHT CEILING HEIGHT SPRINKLER HEIGHT MAX LOAD PER LEVEL TIERS WITHIN EACH RACK TYPE A 12'18' NA 2,500 lbs 3 THE PURPOSE OF THESE DRAWINGS AND SPECIFICATIONS IS TO OBTAIN THE NECESSARY PERMITS, REQUIRED BY THE CITY OF SANTA ANA, FOR LOW PILED STORAGE. THE STORAGE RACKS WILL BE USED, BY PROPHET PREMIUM BLEND LLC. PRODUCTS AS THE BUILDING TENANT, FOR HOLDING LABELS, PACKING/ SHIPPING MATERIALS, CARDBOARD BOXES. THE ENTIRE RACKING SYSTEM CONSISTS OF 247.5' LF OF PALLET RACK ROWS, WITH 8' BEAMS AND 8' TALL UPRIGHTS. ALL COMMODITIES WILL BE STORED LESS THAN 10'. NAME: ADDRESS: PHONE NUMBER: NAME: ADDRESS: PHONE NUMBER: NAME: ADDRESS: PHONE NUMBER: LICENSE NUMBER: NAME: ADDRESS: PHONE NUMBER: LICENSE NUMBER: 775 Leksand Trail, Whitefish, MT 59937 OCMH INC. 1018 LINCOLN AVE. SANTA ANA, CA, 92701 (714) 878-6091 1058665 STRUCTURAL ENGINEERING AND DESIGN INC. 1815 WRIGHT AVE, 2ND FLOOR, LA VERNE, CA, 91750 (909) 596-1351 92778 Michael Kartonis 714.271.2978 GENERAL CODES: CBC 2022 SEC 2209.1; THE DESIGN, TESTING AND UTILIZATION OF STORAGE RACKS MADE OF COLD-FORMED OR HOT-ROLLED STEEL STRUCTURAL MEMBERS SHALL BE IN ACCORDANCE WITH RMI ANSI/MH 16.1. WHERE REQUIRED BY ASCE 7, THE SEISMIC DESIGN OF STORAGE RACKS SHALL BE IN ACCORDANCE WITH SECTION 15.5.3 OF ASCE 7. PLEASE SEE THE STRUCTURAL CALCULATIONS PACKET AND DETAILS SHEET FOR ALL NECESSARY SEISMIC AND ENGINEERING DESIGN SPECIFICATIONS.FIRE DEPARTMENT ACCESS DOOR DO NOT BLOCK SCALE:3 8" = 1'-0" GENERAL NOTES 1. THE INFORMATION REGARDING COMMODITY TYPE/LOCATION, STORAGE DIMENSIONS, CONFIGURATION OF RACKS, AND WAREHOUSE DETAILS HAS BEEN PROVIDED BY PROPHET PREMIUM BLEND LLC AND REVIEWED BY ORANGE. COUNTY MATERIAL HANDLING. 2. ANY AND ALL WORK IS TO BE PERFORMED BY A LICENSED CONTRACTOR. 3. ORANGE COUNTY MATERIAL HANDLING IS NOT RESPONSIBLE FOR ENSURING THAT PROPHET PREMIUM BLEND LLC IS COMPLIANT WITH THE SPECIFICATIONS CONTAINED IN THESE DOCUMENTS.+ 4. THE LOW PILED COMBUSTIBLE STORAGE RACK PERMIT WILL BE ISSUED AFTER FINAL INSPECTION BY THE CITY OF SANTA ANA AND APPROVAL OF THE LOW PILED COMBUSTIBLE RACK STORAGE SUBMITTAL. IT IS THE SOLE RESPONSIBILITY OF THE BUILDING TENANT/OWNER TO COORDINATE THE FINAL INSPECTION WITH THE LOCAL GOVERNING CITY MUNICIPALITY AFTER 5. FOLLOWING APPROVAL OF THE CONSTRUCTION DOCUMENTS, A COPY OF THE APPROVED PLANS SHALL BE MAINTAINED ON THE PREMISES IN AN APPROVED LOCATION. FIRE DEPARTMENT NOTES 1. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, A VISUAL METHOD OF INDICATING THE MAXIMUM ALLOWABLE STORAGE HEIGHT SHALL BE PROVI DED. 2. AUTOMATIC SPRINKLER SYSTEM REQUIREMENTS BASED ON THE PRESENCE OF PALLETS SHALL BE IN ACCORDANCE WITH NFPA 13. 3. FIRE APPARATUS ACCESS ROADS IN ACCORDANCE WITH SECTION 503 SHALL BE PROVIDED WITHIN 150 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS OF BUILDINGS USED FOR HIGH-PILED STORAGE. 4. WHERE FIRE DEPARTMENT ACCESS DOORS ARE REQUIRED BY TABLE 3206.2, FIRE DEPARTMENT ACCESS DOORS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 3206.7.1 THROUGH 3206.7.8. 5. FIRE DEPARTMENT ACCESS DOORS SHALL BE LABELED ON THE EXTERIOR SIDE WITH THE FOLLOWING SIGN OR OTHER APPROVED SIGN: TYPE B 12' 18' NA 2,500 lbs 3 THE LETTERING SHALL BE IN A CONTRASTING COLOR TO THE BACKGROUND. LETTERS SHALL HAVE A MINIMUM HEIGHT OF 2 INCHES WITH A MINIMUM STROKE OF 38 INCH. 6. AISLES IN SPRINKLERED BUILDINGS SHALL BE NOT LESS THAN 44 INCHES WIDE 7. DEAD-END AISLES SHALL NOT EXCEED 50 FEET IN LENGTH. 8. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCORDANCE 9. STEEL BUILDING COLUMNS SHALL BE PROTECTED IN ACCORDANCE WITH NFPA 13 PROPHET PREMIUM BLEND LLC 2625 S. HICKORY ST. SANTA ANA, CA 92707 714.617.5595 8" TYPE A TYPE B SHEET INDEX TITLE SHEET A1 PLAN SHEET DETAILS SHEET A2 SED 1 BASIS OF DESIGN: IN I T I A L P L A N S U B M I T T A L 1/ 1 3 / 2 0 2 5 2 3 NO FELID WELDING FOR THIS PROJECT - NOT APPLICABLEFELID WELDING: IN I T I A L P L A N S U B M I T T A L 2/ 4 / 2 0 2 5 3 IN I T I A L P L A N S U B M I T T A L 2/ 2 1 / 2 0 2 5 4 4 Bldg #101121873 APPROVALS: PLNG - C. Santana BLDG - CSG 2625 S Hickory St 4/14/2025 FIRE DEPARTMENT ACCESS DOOR FIR E D E P A R T M E N T AC C E S S D O O R 51'26'-6.0"51'-1.5" 52'-10.0" 48'-5.5" 10'-3.5"10'10'10'12'-10.3" 23'-6.0" 30'-4.5" A B C D 1 2 3 S H I C K O R Y S T . 60' 50' 77' 1/2" H O L E A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A B B B B B B B B B B B A 8' 18' 9' NO PA R K I N G NO CURB RAMP E N W S FLOOR PLAN COMPASS: 2 2 MAXIMUM PERMITTED EXIT ACCESS DISTANCE = 250 ft MAXIMUM DESIGNED EXIT ACCESS DISTANCE = 126 ft PLAN LEGEND EMERGENCY EXIT DOOR WITH ILLUMINATED EXIT SIGN SMOKE AND HEAT REMOVAL VENT WITH 360 DEGREE FUSIBLE LINK EGRESS PATH 1 2 3 4 FIRE HYDRANT STORAGE RACK PLAN TITLE SHEET A2 SCALE:1 16"= 1'-0" PLAN NOTES AND REVISIONS PR O J E C T N A M E PR O P H E T P R E M I U M B L E N D L L C 26 2 5 S . H I C K O R Y S T . SA N T A A N A , C A 9 2 7 0 7 1) I N I T I A L P L A N S U B M I T T A L 1 0 / 0 9 / 2 0 2 4 2' 1'-6" ( COMMODITY TYPE ) ( MAXIMUM STORAGE HEIGHT ) ( MAXIMUM LOAD PER LEVEL ) ( MAXIMUM UNIT LOAD ) ( MAXIMUM LOAD PER BAY ) 2022 CALIFORNIA BUILDING CODE NOTES: 1008.2. UNDER EMERGENCY POWER, MEANS OF EGRESS ILLUMINATION SHALL COMPLY WITH SECTION 1008.3. RMI SPECIFICATIONS NOTES: 1. RMI 1.4.2; ALL RACK INSTALLATIONS SHOULD DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE AND EACH PLAQUE SHALL HAVE AN AREA OF NOT LESS THAN 50 SQUARE PLAQUES SHALL SHOW IN CLEAR, LEGIBLE PRINT THE MAXIMUM PERMISSIBLE UNIT LOAD AND/OR MAXIMUM UNIFORMLY DISTRIBUTED LOAD PER LEVEL, THE AVERAGE UNIT LOAD, AND MAXIMUM TOTAL LOAD PER BAY. 2. RMI 1.4.7; THE BOTTOM OF ALL COLUMNS SHALL BE FURNISHED WITH BEARING PLATES, AS SPECIFIED IN SECTION 7.2. ALL RACKS SHOULD BE ANCHORED TO THE FLOOR BY ANCHORS CAPABLE OF RESISTING THE FORCES CAUSED BY THE HORIZONTAL AND VERTICAL LOADS ON THE RACK. DETAIL OF RACK SIGNAGE:A REFERENCE THE MAXIMUM STORAGE WEIGHT PER LEVEL FOR EACH HPS AREA FOR SIGNAGE INFORMATION 4 3 1 1 1. CBC 1004.1; IN DETERMINING MEANS OF EGRESS REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM MEANS OF EGRESS FACILITIES ARE PROVIDED SHALL BE DETERMINED IN ACCORDANCE WITH THIS SECTION. 2. CBC 1005.1; ALL PORTIONS OF THE MEANS OF EGRESS SYSTEM SHALL BE SIZED IN ACCORDANCE WITH CBC SECTION 1005. 3. CBC 1006.1; THE NUMBER OF EXITS OR EXIT ACCESS DOORWAYS REQUIRED WITHIN THE MEANS OF EGRESS SYSTEM SHALL COMPLY WITH THE PROVISIONS OF SECTION 1006.2. 4. CBC 1007.1.1; WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS, OR ANY COMBINATION THEREOF, ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH OF THE 5. CBC 1008.1; ILLUMINATION SHALL BE PROVIDED IN THE MEANS OF EGRESS IN ACCORDANCE WITH SECTION 6. CBC 1008.2.3; ILLUMINATION SHALL BE PROVIDED ALONG THE PATH OF TRAVEL FOR THE EXIT DISCHARGE FROM EACH EXIT TO THE PUBLIC WAY. 7. CBC 1013.1; EXITS AND EXIT ACCESS DOORS SHALL BEMARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS THE PATH OF EGRESS TRAVEL TO EXITS AND WITHIN EXITS SHALL BE MARKED BY READILY VISIBLE EXIT SIGNS TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL IN CASES WHERE THE EXIT OR THE PATH OF EGRESS TRAVEL IS NOT IMMEDIATELY VISIBLE TO THE OCCUPANTS. EXIT SIGN PLACEMENT SHALL BE SUCH THAT ANY POINT IN AN EXIT ACCESS CORRIDOR OR EXIT PASSAGEWAY IS WITHIN 100 FEET. 8. CBC 1017.2; EXIT ACCESS TRAVEL DISTANCE SHALL NOT EXCEED THE VALUES GIVEN IN TABLE 1017.2 2 22 CATEGORY Requirement STANDARD ACCESSIBLE PARKING: VAN-ACCESSIBLE PARKING ACCESS AISLE - WIDTH ACCESS AISLE - MARKING PARKING SPACES & AISLES - SLOPE RAMPS & ACCESS ROUTES - SLOPE SIGNAGE - SIZE SIGNAGE - HEIGHT SIGNAGE - CONTENT 108 INCHES 108 INCHES (2743 MM) WIDE MINIMUM 96 INCHES access aisle BLUE PAINTED BORDER, HATCHED LINES 36 INCHES (914 MM) ON CENTER MAXIMUM 1:48 (2% GRADIENT) IN ANY DIRECTION MAXIMUM 1:12 MINIMUM 70 SQUARE INCHES (4516 MM²) MINIMUM 80 INCHES (2032 MM) FROM BOTTOM OF SIGN TO FINISHED GRADE INTERNATIONAL SYMBOL OF ACCESSIBILITY (WHITE ON DARK BLUE) ACCESSIBLE PARKING STALL SPECIFICATIONS 1 1 1 1 1 IN I T I A L P L A N S U B M I T T A L 1 / 1 3 / 2 0 2 5 2 222 2 2 2 2 2 2 2 22 2 2 3 3 5 DIRECTIONAL EXISTS 5 5 5 5 5 5 5 6 ACCESSIBLE PARKING 6 ACCESSIBLE PARKING TRAVEL PATH7 3 NO FELID WELDING FOR THIS PROJECT - NOT APPLICABLE FELID WELDING:3 IN I T I A L P L A N S U B M I T T A L 2 / 4 / 2 0 2 5 3 8 DETECTABLE WARNING SURFACE 8 8 3 3 OFFICE MANAGER ROOM CONFERENCE ROOMPOD CAST ROOM RR4RR3 OFFICE EMPLOY ENTRANCE BLUE PEN OFFICEOFFICEOFFICE SVRRRRR2 BREAK ROOM OFFICERECEPTION IN I T I A L P L A N S U B M I T T A L 2 / 2 1 / 2 0 2 5 4 4 2625 S Hickory St 4/14/2025 (6)6,2 251$3 /'((15*(7 ,16,(*((55 $&/),)2 2(571$,7 $6 9 ,,/& ((55 $&/),)2 2(555555555555555555555555555555555555555555555555555555555777777777777777777777777777777777777777777777777111111111111111111111111111111111111111111111111111111111$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$7 ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,7$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$66666666666666666666666666666666666666666666666 1R1R (([S[S 10/3/24 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 2625 S Hickory St 4/14/2025 0.94" 1.57" 0.32"SEE ATTACHED OCMH INC DWG. FOR STORAGE RACK ELEVATIONS 1/2" O.A.L. F.F. 3 1/4" MIN. EMBED. 12" 3/8" 1/2" 1 1/2" 1/2" 2" 3/8" Ø3/8"2 11/16" 3/8" 3/8" 6" 3" 2" 2" 1" 1 3/8" 2-1/2" 1" 8" 5" 9/16" DIIA 8" 8" 1" 1" Ø9/16" 5/16" 3" 3" 2" 3 1/2" 1 5/8" 7/8"1 5/8" 5/16" 3" 3" 2" ATTACHMENT: ATTACH W/ (2) 5/16"Ø X 3/4" GR. 5 BOLTS PER BRACE, (1) @ EA. END MATERIAL DESCRIPTION STEEL YIELD ASTM A570, Fy=50,000 PSI BRACING: HORIZ. & DIAG. 15 GAGE STEEL NOTES: USE @ ALL BRACE LOCATIONS TYP. DIAG. BRACE HORIZ. BRACE NOT A DEPICTION OF THIS PROJECT BASE PLATE & ANCHOR COLUMN ROW SPACER BEAM CONNECTOR DESCRIPTION STORAGE RACK ELEVATIONS NOTES: CONFIRM O.A.L. OF ANCHORS WITH INSTALLER TO ENSURE REQUIRED EMBEDMENT IS OBTAINED. 4266 1/2"Ø X 3-1/4" MIN. EMBED. HILTI KWIKBOLT TZ2 ANCHOR ESR# DESCRIPTION NOTES: SEE NOTE #4 ABOVE FOR ANCHOR SPECS. SIZE NOTES: ATTACH WITH (4) 5/16"Ø GR. 5 BOLTS, (2) @ EACH END 14 GAGE ROW SPACER MATERIAL STEEL YIELD DESCRIPTION ASTM A570, Fy=50,000 PSI 0.350" Ø PINS SAFETY CLIP ASTM A570, Fy=50,000 PSI NOTES: USE @ ALL LUOSHAN BEAM TO COLUMN CONNECTION LOCATIONS TYP. 7 GAGE 3-PIN CONNECTOR STEEL YIELD MATERIAL DESCRIPTION GENERAL PROJECT NOTES 1. DESIGNED PER REQUIREMENTS OF THE 2022 CBC, ASCE 7-16, SECTION 15.5.3, & 2012 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA SS=1.273, S1=0.456, FA=1.200, FV=1.850, IP=1.0 (NO PUBLIC ACCESS), SDS=1.018, SD1=0.562, OCC UPANCY CATAG. II SITE CLASS D-DEFAULT, SEISMIC DESIGN CATAG. D 3.STORAGE CAPACITY: TYPES A, B=2500 LBS PER LEVEL TYP. 4. ANCHORS : HILTI KWIKBOLT TZ2 ESR#4266, OR POWERS SD2 ESR#2502 1/2"Ø X 3-1/4" MIN. EMBEDT. 50 FT-LBS TORQUE (HILTI KWIKBOLT TZ2) 40 FT-LBS TORQUE (POWERS SD2) (2) ANCHORS PER BASE PLATE. 5. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION. ANCHORS SHALL BE INSTALLED PER ICC ESR#4266. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 6" X 2500 PSI 7. SOIL BEARING PRESSURE 750 PSF. 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER, INSTALL TO SNUG TIGHT FIT OR BETTER 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BY AWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BETTER. FIELD WELDS, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. SPECIAL INSPECTION IS REQUIRED FOR ALL STRUCTURAL WELDS EXCEPT FOR WELDING DONE IN AN APPROVED FABRICATOR'S SHOP. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 12. THE PRODUCT SHOWN ON THE DETAILS HEREIN IS ASSUMED TO BE IN GOOD, UNDAMAGED CONDITION. THE PRODUCT MUST BE FREE OF ANY DAMAGE AND/OR FABRICATION DEFICIENCIES OR IRREGULARITIES. IT IS THE RESPONSIBILITY OF THE OWNER, USER, PRODUCT PROVIDER AND/OR INSTALLER OF THE COMPONENTS TO NOTIFY SED, INC IN WRITING, OF ANY DAMAGE, DEFICIENCIES OR IRREGULARITIES. 13. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR USER OF THE COMPONENTS SHOWN HEREIN TO NOTIFY SED, INC OF ANY DAMAGE OR DEFICIENCIES IN THE SYSTEM DURING USE.THIS INCLUDES SUCH OCCURRENCES SUCH AS IMPACT DAMAGE TO THE COMPONENTS FROM FORKLIFT OR HEAVY MACHINERY, IMPACT FROM DROPPED LOADS ON THE SYSTEM, DAMAGE TO SYSTEMS BY IMPROPER USE OR INSTALLATION, ETC. THE USER OF THE PRODUCT MUST NOTIFY SED, INC IN WRITING SHOULD ANY DAMAGE OR DEFICIENCY OCCUR TO THE PRODUCT SHOWN HEREIN. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR USER TO MAINTAIN THE SAFETY AND PROPER USE OF THE STORAGE PRODUCT SHOWN HEREIN. 14. IT IS THE RESPONSIBILITY OF THE OWNER/USER OF THE STORAGE SYSTEM SHOWN HEREIN TO REPAIR OR REPLACE ANY COMPONENT THAT IS DAMAGED OR OTHERWISE DEFICIENT. 15. THE OWNER SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF THE RACK SYSTEM BY ASSURING PROPER OPERATIONAL, HOUSE KEEPING AND MAINTENANCE PROCEDURES, BUT NOT LIMITED TO THE FOLLOWING: A. PROHIBIT ANY OVER LOADING OF ANY PALLET POSITIONS AND OF OVERALL RACK SYSTEMS. B. REGULARLY INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, IMMEDIATELY UNLOAD THE AFFECTED AREA AND REPLACE OR REPAIR ANY DAMAGED COLUMNS, BEAMS, OR OTHER STRUCTURAL COMPONENTS. C. REQUIRE ALL PALLETS TO BE MAINTAINED IN GOOD, SAFE, OPERATING CONDITION. D. ENSURE THAT PALLETS ARE PROPERLY PLACED ONTO PALLET LOAD SUPPORT MEMBERS IN PROPERLY STACKED AND STABLE POSITION. E. REQUIRE THAT ALL GOODS STORED ON EACH PALLET TO BE PROPERLY STACKED AND STABLE. F. PROHIBIT DOUBLE STACKING OF ANY PALLET POSITION, INCLUDING THE TOP MOST POSITION, UNLESS THE RACK SYSTEM IS SPECIFICALLY DESIGNED FOR SUCH LOADING. G. THE OWNER AND/OR USER OF THE RACK SYSTEM MUST PROVIDE MEASURES TO MITIGATE DAMAGE TO THE STORAGE RACK BY USE OF IMPACT PROTECTIVE DEVICES IN AREAS WHERE FORKLIFT AND/OR HEAVY MACHINERY ARE IN USE. H. ENSURE THAT THE RACKS ARE NOT MODIFIED OR REARRANGED IN A MANNER NOT WITHIN THE ORIGINAL DESIGN CONFIGURATION. 16. MINIMUM DISTANCE BETWEEN THE ANCHOR BOLT CENTER TO ANY CONSTRUCTION JOINTS, CONTROL/EXPANSION JOINTS OR SLAB CRACKS=3.5". 17. THE MAXIMUM TOP TO BOTTOM OUT-OF-PLUMB RATIO AND OUT-OF-STRAIGHT RATIO RACK COLUMN IS 1/240 (FOR EXAMPLE 1/2" PER 10 FEET OF HEIGHT). COLUMN WHOSE OUT-OF-PLUMB RATIO OR OUT-OF-STRAIGHT RATIO EXCEEDS THIS LIMIT SHOULD BE UNLOADED AND RE-PLUMBED. ANY DAMAGED PARTS MUST BE REPAIRED OR REPLACED. 18.FOR 96" H FRAME: MINIMUM DISTANCE BETWEEN RACK AND BUILDING COMPONENTS IS 2% (OR 1.92") OF TOP SHELF LEVEL HEIGHT @ BRACED DIRECTION AND 5% (OR 4.8") OF TOP SHELF LEVEL HEIGHT @ UNBRACED DIRECTION. FOR 192" H FRAME: MINIMUM DISTANCE BETWEEN RACK AND BUILDING COMPONENTS IS 2% (OR 3.84") OF TOP SHELF LEVEL HEIGHT @ BRACED DIRECTION AND 5% (OR 9.6") OF TOP SHELF LEVEL HEIGHT @ UNBRACED DIRECTION. 18 1 5 W R I G H T A V E . L A V E R N E , C A 9 1 7 5 0 P H . 9 0 9 . 5 9 6 . 1 3 5 1 F A X . 9 0 9 . 5 9 6 . 7 1 8 6                                 24-1001-12 SED 1 OF 1 10 / 0 2 / 2 0 2 4 LU O S H A N JM ST O R A G E R A C K SA N T A A N A , C A 9 2 7 0 7 26 2 5 S H I C K O R Y S T GENERAL RACK CONFIGURATION NOTES: USE (2) ROW SPACERS @ ALL DOUBLE ROW UNITS. ASTM A570, Fy=50,000 PSI 14 GAGE THK STEEL STEEL YIELD MATERIAL DESCRIPTION NOTES: USE @ TYPE A LUOSHAN COLUMN/BASE LOCATIONS. ASTM A36, Fy=36,000 PSI STEEL YIELD 3/8" THICK PLATE. BASE PLATE: 8" x 5" MATERIAL DESCRIPTION COLUMN: O3314 1 6 3 5 7 ASTM A570, Fy=50,000 PSI 14 GAGE THK STEEL STEEL YIELD MATERIAL DESCRIPTION NOTES: USE @ TYPE B LUOSHAN COLUMN/BASE LOCATIONS. ASTM A36, Fy=36,000 PSI STEEL YIELD 3/8" THICK PLATE. BASE PLATE: 8" x 8" MATERIAL DESCRIPTION COLUMN COLUMN: O3314 22B NOTES: USE @ ALL BEAM LOCATIONS TYP.ASTM A570, Fy=50,000 PSI DESCRIPTION MATERIAL STEEL YIELD 16 GAGE 4 3-1/2" BEAM (SB356) COLUMN 1B (6)6,2 251$3 /'((15*(7 ,16,(*((55 $&/),)2 2(571$,7 $6 9 ,,/& ((55 $&/),)2 2(555555555555555555555555555555555555555555555555555555555777777777777777777777777777777777777777777777777111111111111111111111111111111111111111111111111111111111$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$7 ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,7$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$66666666666666666666666666666666666666666666666 9 ,,/////////////&&&&&&&&&&&&&&&&&&&&&&&&&&&&&& 1R1R (([S[S 10/3/24 FELID WELDING: ALL FIELD WELDING REACQUIRES DEPUTY INSPECTION NO FELID WELDING FOR THIS PROJECT 2625 S Hickory St 4/14/2025 Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium operations? YES NO 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. INSTRUCTIONS: ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar Special Equipment Plan (PR315, PR340-PR382) Storage/use/research maintenance/repair? with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft Chem Class & floor plan (full architectural plan if Cabinetry/woodworking/finishing facility? H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) * ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments • • • • • Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Initial each of the following two items indicating that you have read and understand the statement: 11. Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— the building department will determine specific requirements. Initials 12. Initials I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Phone Number Address ProjectScope/BusinessDescription Date Signature Suite City / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require O review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that or attach an OCFA referral form and have the applicant submit the form along with the applicant have plans approved by OCFA, please initial here appropriate plans and fees for OCFA review. 10-08-14 EE COM 2625 S Hickory St Santa Ana JL JL Jesus Lopez 714.504.6864 11 7 2024 Jesus Lopez Pallet Racks, Less than 12' storage height 2625 S Hickory St 4/14/2025