Loading...
HomeMy WebLinkAbout10197720 - Permitq Proiect Address: 2507 N Poinsettia St Assessor's Parcel 396422-25 Lot: POR 17 U nrt Bldg: Address Range:Suite Range: Zoning: RlBlock: NA Tract: 1658 Historic: No City of Santa Ana 20 Civic Center Plaza (M-19), Santa Ana, cAg27o2 Building Permit Counter: (714) 647-5800 lnspection Requests: (714],667-2738 lnspector Section: (7'14) 647-5853 Permit #: 1019772fJ Pin #: 79027 Building Usei Job Type: Nature of Workl Existing Bldg. & Use Proposed Use: Single Family Dwelling Solar Solar SFD Watt garage Occupancy: Constr Type: Code: Flood Zonel # of Stories: R.3, U VB cBc 2016 x-0602320153J 't st FL Area 2nd FL Area Other Areas Patio: T.l.Area: Yards Req'd Description of Work: Legalize installation of solar panels. Per PV checklist Planning Conditions: Garage Area Valuation: $1,800.00 BatchS:46070 - 9/21/2tJlS I0: C(:ljl.r.r-At(office: CTYH Tronsi: 93 I oi tAcct+! Ref i3 lt:-tt? / la|il Rcpti30?390260 - 9/21/2018 ?143 Pn Tronsoct ion lotal l{51.rlr:rJerre Schult€ Ta€ld Facr.6u Fh. i.16^ i hd Ih. Owner: Address: Phone: Tenant Miguel Robles 2507 N Poinsettia Santa Ana, CA 92706'1725 (7',t414744510 Contraclor: Tesla Energy Engineering lr Address; 2284 North Glassell Street, ! Orange, CA 92865 Phone: (949) 278-3569 State Lic #: 1043520 Lic Type: B, A, C-10 Bus. Lic #: 0 Workers' Compensation lnsurance: Carrier: Midwest Employers Policy #: BNVWC0i41739 Expires: O9l1712O19 YourSolarPlana.comphono THIU d tn9 3?:::ffit{!H{iiilr (9ae)25qe[sthe.k 029660 c70784 Engineer: Address t45u. r:[:l s1 , r:r(l 1451.r1r:lPhone; License # Architect / Desiqner: Address: Phonel License # Planning Approval By: Plan Checked By: Permit lssued By: NPDES Insp. Req'd: No PWA lnsp Req'd: No Planning lnsp. Req'd: No Landscaping lnsp. Req'd: No Zuniga, Allissa Datel Date: Dale: 0912412018 Subject to Field: 07776002 51601 Permit Fee 07776002 57672 Bldg. Stds. Revolving 01776002 57600 Genetal Plan Update $450.00 $1.00 $0.00 Fire lnsp. Req'd; Police lnsp. Req'd No No Account#Total Flood Zone Cert. Req'd; No Ot116002 51601 Every peinit issued shall bocome invalid unless the wo* on the site authonzed by such pemit is commenced within 180 days after its issuance.or il the wo* authorized on the site by such pemit is suspended or abandoned for a period of180 days after lhe time the wo* is comfienced lnspector 0'1 116002 516'12 $4s0.00 $1.00 Fee Total Paid to Date: Balance Due: $451.00 $0.00 $451.00 NIisc. Receipt: lvlisc. Receipt: N4isc. Receipt: MID#: 2018-146166 BUILDING. INSPECTOR RECORD SITE.WOBK DATE IDiSIG.COMMENTS Forms/Steel/Holdowns Erection Pads SLAB Floor Sublloor/VenVl nsulation Shear Wall Framing ln s u lation/E nerqy Drywall Ext./lnt. Lath Brown Coat lVlasonry Pool Fence T-Bar l!qndicap Req. De puty Final Report Engineer Final Report FINAL rD\\\g 4 iu4.s, Certilicate of Occu pancy Notes Remarks Etc. OWNDN BUILDER DEI,CARATION I h.rchy rinm lnncr pcnrlry 0f p.rjury rhar ! ani cxcnlor fonr rhc Contackxa Lkcisr liw f(r rhc followinS rc!$r (Ss?031.5 Itusircss rlld P.or'cssion C(xlc) Aiy Cily or Counly whih Elun.s r pcann to connrud, alrcr- impr.vc. dc $]i\h or hPJr uy rrtucrurc. p .,ro its issuane, ahorcquncs rhc mrltonr lor such ricrnir ro fiL! sisncd srarcftor rhll h.or ihc is li.cnwl NrsuMt lo lhc lmlisioDs ot thc conlmclr's Li.c.rd L.p (Ch,pro 9. conmcmin8 wirh scction ?frro or Divhion I ofrhc Bu\inc$ and Pn,fcssbns Codc) or lh ncorshc ir€ic,ry,t lhcrcton.ndlne hosis nxlnc rllcscd crc.lllion Any !i,,ldt,norsdri,r70:115 by rny appli.rnr fu a ri.mir suhF.rx rhc trmlicsnr ro rcivil!.nelryofnornE crhDn riv. hxndrcd doll,rs ( $5m) -1. .s owmr of lhc loFny. or nry cnplorecs wirh wtrgcs N rhct nnc clarpcnsnr ion. rill do lh. sork 0d Ihc $tr@ i\ nor inrc e.l or oltcrcd ior slc (Ss.70.14, Busirrc$ and Pmlt$ions Codc: Thr Conincrois l-i.cnr tjw rk c\ nor {rply ro M o{ncr oI rhc |)R)p.dy *b brilds ur inumrcs rtrmn. dld who dds skb wo hnn\.lforhfi*lforlhmu8hhnorhcrowtrcmDloyccs. rrovidcd rhit such impn,EnEnBaE ml inlcdcn or ofr.rcd ror slc.ll ho*cvcr. rhc huikliry or i,rymrcmnt isFnwnhin,'ft Fr nf comtlcriotr, thc Own& Buildtr Nill haw thc hurdcn of pR)ving rhd h. or shc dil nor huild or nq,mrc thc lmlrny for rhc lrUtlnr o, -1. a\osrcrollhc pro!.ny.oflrexclusivclyconlructins wirh li.cnsLic. rrcron lo conntud rhc In+d {sc.. rol.4. Bu$ncss ,trd [h,l6sim Codc: Thc Conta.ror's Liccn{ Law do.\ nor applr ro owicroftrotdyqhobuildsorimprcvcsrhcr.otr. sntl qho co m$ lor such r)Dlccts *ir h a Conlm.bn, tccn\cd rurru!trr 'o rhc (.onIncroi s Liccn{ l3s) -l anexcmpl unler Sdion-. B. & P.C. tu thh rco$. D6lr: Oen.r u!.)trtrIBiil0N$Nlrl]l!)N DECLA.EAI]AN I hd.hyrlrirnrndcrn Mlrtof ncrjuryon.orrhcf{'lk,rn,gdc.!rrrri,)n\: I hrve dd w ill 'tui dn a CcnitLarc of Con*nr ro S.lt lnrurc frr $qkc* conF.sdrion, $ ptuvidcd for by Sccrion lT0O oi rhc ljbor Code. ror the F.rforronce oI rh. sort for rhi.h lhc pcrmil is issucd *J hd r anJ s ' ll 'hddn u rtrr.h' . rn,pcn\Jrr ' 'n\urr ncc, as requncd by s..rn r](]o of lhc Lahor Code. lot rhc Fcnbnurcc or 0hc wnrk l,{ whtrh,hF Frm r\.s$d M, wur tcF' o' il.n\Jrtr.n 'n\ur.n! c ..'rn JJrl Fl'c ) trunficr trc ,41 (^1^uJ I; uu <?5 9t<tr 1f (o co/l // {-,ccrliry thal in lhc pcrioflMncc oithc solk for which thh rcmir is nsucd- I shall n.l cmploy lny pcr(,n in rny mni.r s N b h...nr suh,..r b rhc wofl.6 c.nrFnsdion ldws .f C,lif(trii{ nid rg(r rhd ilI should trcoflE ruhiu Iorhc workc co'hnns,rionpmvni.is.fSNrion.lT(X)ofrh.IlhrC.dc.l\hrll,fonhwirhco,nflywirhthoctrovisions. W]\RNINC: frilure k, surc wortcn comp.trsotm .ovcr.!c 'i unhwlnr. !trd shrll cnrploycr lo si'ninrl p.irlrics rod li.n. &DIBC\ as p(iidcd ftn rhccivil fincs up lo nrc hundrcd lhousand dolh^ l:rloo.(xD). i';:::ry&/E: thcrbr,fllrmund.rr.nrhyorp.rjuryrharIanli.cnsdund.rpolisnrofChrDl$9(commmir8qilhScclion7m0)otDivisionl of rhc Burituss lnd Pmfcs\ions Codc, a.d or, liccnsc is in full nr4q*rclis.-r. h :o ) c/)t D 2 n7a(./ 4 AITLII NLDICLAAAIION I lEdryrlli uMcrFnrlryol l)crruryotrcol il[ follownrA dL\ldarions: Dcnx,lihon Pcnnirs \bc{o\ Norifi.dridn Fcd$rlR.aularion\ (Tirtc t0. Pdn6) Rcquncd bxcrol Noriir{60 I crnifyrtur rhc icd.rircgdhri)n\ rgrli.E a\hl{o\ r.treulrr. nor rpplicr$l. b rh,s pn,j.cr )(ccnify rhd I hair.cd rh$ trFplicnrion lsre ro.onDly*irh rll Ciryand Counry ns oi'hn ciry and c,unr, t c suFrrhc-*,"q1'1/6.rdiMtr.cs nd SrJrc Lr$\ rlrr nh,vc rdrn,nd pn)pcnyl{n i Applicni or AFcnl SignotuE (L ,t(k I Set Backs UFER Ground Roof Sheathinq Flood Zone Certif . I hcEby affirn undcr IEMlly of p€rjury lhal rlss k s snstdclion LndinS a8cflcy lor thc l]crfomncc ol lh. wotl foi qhich lhis Frnir Lc nsucd (SN 1097, Ci!. C.). trnderl \un'c - titrd.r'. Addr* b r------ an0r$AIrlA NA,lffiI Contractor Company Name: Contractor Licens e N umber:(u q.r a 4 5 YES NO1 Mtr , dtr 3 dtr dn ds du ds dt gD do Are the following applicable to the proposed proiect? U/iil the PV syslem layout provide the required three-foot wide clear access pathways per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? \l/ill the PV system be installed on a roof having only one roofing layer with no overlays? u/ill the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? \ iill the PV system weigh rnaxjmum 4 pounds per square feet or less? \l/ill the PV system be installed where the modu es do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? \l/ill the PV system be installed with a space of 2" minimurn to '10" maximum befween the underside of modules and the surface of the roof? \ /ill the PV system be inslalled without using any ballasi systern or counter-weight system? \ /ill the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum of 2-112 tach embedment inlo roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, 0 7 I I 10 anchorage spacing, anchorage details and manufac geis\uoOort information. ) I certify under penalty of perjury under the laws of the Sta of Ca lif at the above is true.--< Prinl Name Rev 1l/r 9/2015 GC 1 9naS q Date arNg lt9 o\,.. Planning & Building A!ency Building Safety Division 20 Civic Center Pla2a P.O. Box 1988 (lvl.19) Santa Ana, CA92702 (714) 647.s800 www,santa-ana.org Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only lnstructions: The llcensed contractor of record sha I complete all sect ons, answsr the ten quest ons anC s gn the certification section below. A copy of this form shall be attached to each of..TU/O sets of plans, of rninimum 11' x 17" size. lf answerinq NO to anv of the questions, plan check shall be required. ProjectAddress:J<o-1 rO ?ottse-\ttc^- St *c.^t". I+rc^ , Crt 9J1O6 RESIDENTIAL PHOTOVOLTAIC CHECKLIST Phone Numberl Email Address:ilC,vd *$NIA ,NAffi Planning & Building Alenc y Building Safety Division 20 Civic Center Plaza P,O. Box 1988 (tul-19) Santa Ana. CA 92102 (7'14) 647.s800 www.santa-ana. org Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only lnstructions: The llcensed contractor of record shall complete a I sect ons, answer the ten questions and sign the certlfication section beiow A copy of this form shall be atlached to each of..TVi O sets of plans, of minirnum '1 1 ' x 1 7' size. lf answerin qNOtoan of the ouestions, ola n c heck s hall be required. Project Add ress *U PtrqINtrNTIAI PHOTOVOLTAIC CHECKLIST 2 3 Contractor Company Name: Contractor Licens e N umber du dn de tr (u q.9 Are the following applicable to the proposed pro.iect? \r'/ill the PV system layout provide the requlred three-foot wide clear access pathways per Section 605.'1 1 of the Caiifornia Fire Code, and is this shown on the roof plan? u/i{l the PV system be installed on a roof having only one roofing layer with no overlays? U/ill the PV array be flush mounted to the existing roof so that the piane of the modules (panels) are parallel to the plane of the roof? \ iill the PV system weigh maxlmum 4 pounds per square feet or less? \ /ill the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabted ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the underside of modules and the surface of the roof? Will the PV system be installed without using any ballasl syste0'l or counter-weight system? U/ill the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum ol 2'112 tnch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including proiect speciflc site plan, PV layout, anchorage spacing, anchorage details and ma NU SU pport nformation. ) under the laws of the State Calif rnia that the above is true 4 5 gtr dn ds du trd d d 6 7 9 Rev 1 r/19/2015 10 tr Prlnt Name I certify under penalty of perjury -..1- q 1 Slgnalure Date: Q o a I,\.q I 19Phone Number Email Address.