Loading...
HomeMy WebLinkAbout10180155_1730 E. 17TH A-1 - PlanPlanning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www. santa-ana.org ELECTRICAL SIGN REQUIREMENTS Code references are to the 2010 California Electrical Code (CEC) All signs require Planning Department approval. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal C-11: 3-21-2011 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. A building permit is also required - except for open or highlight neon lighting. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated . metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory; and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 O 0 m , When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign may be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 110.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LE;Ds may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on day of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 133 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 SINO-OPTO USA LLC, DBA LED LIGHTING SERVICES LLC E342085 3575 COMMERCIAL AVE NORTHBROOK, IL 60062 LED Tube, Cat. Nos. LLITB-48-18W, LLIT8-24-1 OW. 1.These products are suitable for use in dry, or damp locations. 2. The lamp is maintained not less than 2 inches (50.8 mm) from combustible materials such as wood orplastic' and parts that are a source of heat or arcing. Spacing from lampholder to sign housing is zero. 3. This LED lamp is not for use with internally shunted bipin lampholders used with fluorescent instant start lamps. SINO-OPTO USA LLC, DBA LED LIGHTING SERVICES LLC 3575 COMMERCIAL AVE E345360 NORTHBROOK, IL 60062 LED Tube, Cat No. SN-T. 1. These products are suitable for use in dry, or damp locations. 2. The lamp is maintained not less than 2 inches (50.8 mm) from combustible materials such as wood or plastic and parts that are a source of heat or arcing. Spacing from lampholder to sign housing is zero. 3. This LED lamp is not for use with internally shunted bipin lampholders used with fluorescent instant start lamps. LED Tube, Cat. No. LLI-Tl ODBL 1. Manufacturer's name, trade name, or trademark. 2. Distinctive catalog or model number. 3. The electrical ratings. 4. When multiple manufactures are involved, then a Factory ID identifying the product to a particular factor·y shall be provided. 5. Optional - "For Connection with Class 2 Circuits Only." SLOANLED, DIV OF SLOAN CO INC 5725 OLIVAS PARK DR E215393 VENTURA, CA 93003 LED Modules, Cat. Nos. 701261,701261-PW, 701340, with suffix -R, -O,-Y, -B, -G, -W or -A; Cat. Nos. 701340-PW with suffix - R, -O, -Yi -A, -B, -G or -W; Cat. No. 701340-CM. 1.These products are only suitable for connection to a UL Listed or Recognized Class 2,24 V dc power source for Model 701340 and 7.5 V dc or 5 V dc power source for Model 701261. 2.These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3.The total number of Model 701261 LED Lighting Units are not to exceed a total of 75 units per Class 2 circuit. The total number of Model 701340 LED Lighting Units are not to exceed a total of 40 units per Class 2 circuit. 4.These products are suitable for use in dry, damp and wet locations. 5.These products are not required to be enclosed or protected frorn weather. Class 2 LEDs, "ThinLED", Model 701228 , with suffix -A, -Bi -G, -R, -W or -Y; Cat. No. 701228-18, with suffix -A, -B, -G, -R, -W or -Y 1. These products are only suitable for connection to a UL Listed or Recognized Class 2, max. 12 V dc power source. . Only Models 701228-A, -R, or -Y are only suitable for connection to UL Listed or Recognized Class 2, max. 7.5 V dc. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3. The total number of these products when interconnected is not to exceed a total ef 14 feet or 14 "ThinLED" units per Class 2 circuit. These products are not to draw a total wattage of greaterthan the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. 5. These products are not required to be enclosed or protected from weather. Class 2-power supply, Model LED Outline Lighting Systems "FlexiBRIGHT", Cat. No. 701499-X-Y, where X and Y may be any alphanumeric character. 1. These products are only suitable for connection to a UL Listed or Recognized Class 2, 12 volt DC power source or less. 2. These products have not been evaluated for use when connected 10 a power source that does not comply with Class 2 voltage and energy limited supplies. 3. These productaare notto draw a total wattage of greater than the secondary or output rating of the Class 2 supply per Class 2 circuit. 4. These products are provided with wire soldered on the printed wiring board for connection. 5. These products are suitable for use in drx, damp and wet locations. Class 2 LEDs, Modules designated, "LED STRIPE2 (Border Light)" and "701956-XXXXXX"series, where XXXXXX may be replaced with alphanumeric characters. 1. These products are only suitable for connection to a UL Listed or Recognized Class 2, 15 Volt or less DC power source. 2. These products have not been evaluated for use when connected ito a power source that does not comply with Class 2 voltage and energy limited supplies. 3. 'Class 2 LEDs, "LED STRIPE2 (Border Light)", is rated max. 48 Watts per module. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. Class 2 LED Module, Cat. No. 701269«xxocooo<xx-MB Series, where xxx#xxxxxx may be blank or any alphanumeric characters. 1. These products have been evaluated only for use when connected to the Class 2 output of a Listed or Recognized power source rated 15 VDC or less. 2. These products are suitable for use in dry. damp and wet locations with supply sources fated at 15VDC or less. 3. These products are not required to be enclosed or protected from the weather in the end product. 4. These products may be secured in the end product with any available means. 5. These products are rated for a maximum of 7 5 watts or less per module. Class 2 LED Border Light, Class 2 "Border Light" Cat. No. 701189-XXXXXXXXXX series. a October 1, 2013'SIGN COMPONENTS MANUAL (SAM)134 1. These products are only suitable for connection to a Class 2 power source, rated 30 Volt DC or less. 2. These products have not been evaluated'for use when connected to a power source that does not comply with Class 2 voltage and energy limits and whichiis rated greater than 30 V DC. 3. These products are each rated max. 100 Watts per unit. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations when rated maximum 30 VDC. 5. These products are not required to be enclosed or protected from the weather in theEend product when rated 30 VDC or less. 6. These products may be secured ih place in the end product by any means avajlable. 7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall be considered. LED Strips, Cat. No 701174, 701181 and 701195 with suffix -R, -Y. -A, -B, -W, or -G followed by -1" through -24". 1. These products are only suitable:for connection to a UL Listed or Recognized Class 2,24 volt AC power source. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. 3. These products may be cut Into segments through a black. mark provided on the printed wiring board. No other cut across the board is permitted. 4. Cat. No. 701174 is rated for 4.2 watts perfoot, Cat No. 701181 is rated for 9.2 watts per foot and Cat. No. 701195 is rated at 1.5 Watts per foot. The total number of feet of each type and inches for the inch unit are not to produce a total wattage of greater than 60 watts per Class 2 circuit. 5. These products are suitable for use in dry, damp and wet locations. 6. These products are not required to be enclosed or protected from weather. Class 2 LED Module, Cat. No. 701946-XXYYYYYYZZZ series, where XX, YYY¥YY and ZZZ may be replaced with any alphanumeric characters or blank. 1. These products are suitable for use in dry, damp and,wet Jocations and supplied only with a Class 2 power source rated 24 Volt DC or less. 2. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary ior output rating of the Class 2 supply. 3. These products are not required to be enclosed or protected from the weather in the end product. 4. These products may be secured in place in the end product by any means available. Class 2 power supply, Model 701285. 1. Power supply is intended to power LEDs in signs. 2. Power supply model is intended for permanemt connection Only. 3. These units are suitable for use in dry location withoutia need for an addjtional enclosure and in damp locationsiwhen installed inside a sign that complies with the Exclusion of Water Test in UL 48. 4. If the power supply output wiring is extended longer than the 5 foot leads provided, the spliced connections shall be made inside a Listed junction box suitable for the application included with proper grounding. Class 2 power supply, Cat. Nos 701349,701351. 1. Power supply models 701349 and 701351 are intended to power LEDs in signs. 2. Power supply model 701349 and 701351 are intended for permanent connection only. 3. These units are suitable for use in dry location without a need for an additional enclosure and in damp locations when installed inside a sign that complies with the Exclusion of Water Test in UL 48. 5. These power supplies have two outputs. The Class 2 output circuits are not to be conductively connected ;to each other in the sign by wiring orother type of component. 6. The maximum rated output power for Model 701349 is 42 watts at each Class 2 output. The maximum rated output power for Model 701351 is 60 watts at each Class 2 output. Class 2 power supplies, Models 701507-MOD, 701507-MOD277 (AD060S277/347-SLN). All may be followed by alphanumeric suffix. 1. These power supplies bave a maximum of one Class 2 output. The output of these power supplies has been evaluated to Class 2 output requirements for dc circuits. 2. These products with Class 2 outputs are suitable for use in dry, damp and wet locations. 3. In the end product, power supply spacing to other heat producing components shall be minimum 4 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. When used in wet locations, each unit shall be provided With Listed (QCRV) 1/2 inch, liquid tight conduit fittings on primary circuit. 5. When used in a cord connected product, the need for conducting a leakage current test shall be considered in the end product. 6. When not marked for Dry and Damp Locations Only the power supply primary bracket shall be provided with min 3.5 threads and maximum 5 threads tapered for connection to liquid tight conduit fitting. If less than 3.5 threads, the liQuid tight shall be provided with waterlight fitting Listed (OCRV) 1/2 inch. liquid tight conduit fittings, 7. The suitability of grounding connection shall be determined in the end-use product Class 2 power supply, Model 701680. 1. The product shall be installed in compliance With the mounting, spacing, casualty, and segregation requirements of the ultimate application. 2. These un,ts are provided with a Class 105(A) insulation system. 3. The suitability of the input and output connections shall be determined in each end use application. 4 These power units are intended for dry or damp location use only. 5. Strain Relief on input lead construction and Impact Tests have not been investigated. 6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of polymeric enclosure of each unit is V-2, and tree necessity of additional fire barriers shall be determined in end product. 7. Multiple power supplies shall be spaced at least 25mm (1 in.) end to end or 102mm (4 in.) in other difections. If lesser spacings areiused, then the Temperature Test shall be conducted in the end use product. For reference the maximum enclosore (case) temperature on the power supply was 90°C when tested at 58.4' ambient. Class 2 power supply, Model 701680-MW 1. These power supplies have been evaluated to elass 2 output requirements for dc circuits with a maximum of one Class 2 output. 1 135 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 2. The load powered by the Class 2 output of the power suppJies rated at max 30 VDC or less are suitable for use in dry, damp and wet locations. 3. In the end product, power supply spacing to other heat producing components shall be rninimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. These-Qr-gE!®ts. @rE P.[04®iwith®e &!.lo),ingel.edrical ratngs - # Input Output IModel Vac A Hz Vdc A 701680-MW - 100-240 0.55 50/60 12 1.67 5. These products shall be enclosed in the end product. 6. These power supplies are suitable for use in dry and damp locations. Class 2 power supply Model 701681. 1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate application. 2. These units are provided with a Class 105(A) insulation system. 3. Input leads are Style 1015, No. 18 AWG, rated VW-1,600 V, 105°C. Output leads are Style 1;430, No. 18 AWG, rated VW-1, 300 V, 105°C. The suitability of the input and output connections shall be determined in each end use application. 4. These power units are intended for dry or damp location use only. 5. Strain Relief and Impact Tests have not been investigated on input lead tonstruction. The suitability of the enclosure as ultimate enclosure shall be determined in tie end-use application. 6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of the polymeric enclosure is V-0 and the necessity of additional fire barriers shall be determined in end product. 7. In the end product, power supply spacing to other heat producing c0mponents shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. Class 2 power supplies, Model 701495. 1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of four Class 2 outputs. 2. These power supplies are only suitable for use in dry, damp and wet locatiohs. 3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. Class 2 power LED Lighting Strip, 701912-QQXXYYZZZ series, where QQ represents length, XX represents the LED color temperature, YY represents configuration and ZZZ represents the LED drive current. 1. These products are only suitable for connection to a Class 2 power source, rated 24VDC. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limits and which is rated greater than 24VDC. 3. When units are connected to a Class 2 circuit, they are not to draw a total wattage: of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated class 2. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. 7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall be considered. Class 2 "Dimming Control Knob" potentiometer, Model 701843. 1. These products are only suitablefor connection to the output of a UL Listed or Recognized Class i2 power supply rated max 12 VDC. 2. These products are suitable for use in dry and damp locations. 3. These products are suitable for factory wiring only. 4. These products are 1 Kohm potentiometers intended for connection to max 12 VDC Class 2 power supply that drops the voltage to a 0··10 V signal to feed into the PWM dimmer. Class 2 LED Modules, Cat. No. 701960-XXYYYZ Series, where. XX, YYY, and Z maybe replaced with any alphanumerit character or blank. 1. These products are suitable for use ifidry, damp and wet locations and supplied only with a Class 2 power source rated 24 Volt DC or less. 2. When units are connected to a Class 2 circuit, they ard not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 3. These products are not required to be enclosed or protected from the weather in the end product. 4. These'products may be secured in place in the end product by any means available. Class; 2 power supplies, Models 701507-60W1 -JV and 701507-60W1-CT. 1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maxi fnum bf one Class 2 output. 2. Theseproducts are proyided with the following electrical ratings: Output Output Frequency Voltage Current Model Nuinber Input Voltage M Input Current (A)(Hz)0/dc)(mA) 701507-60W1-JV,100-240 0.85 50/60 12 0-500 701507-60W1-CT 3. In the end product, power supply spacing to other heat producing components shall be at least 25.4 mm (1 in) from end to end and 101.6 mm (4 in) from side to side. 4. These products shall be enclosed in the end product. 5. These products are suitable for factory wiring only. 6. These products; are intended for use in a dry or damp locations only.. 7. The suitability of inpuuoutput leads and the wring shall be determined in end product use. SPARTECH PLASTICS E202184 8 FT 4 IN • dASTER I.D. Chf FASCIA -0 Zone___-L-7-J r ____--PLANNER 'EZZIn-==- DATE t//m/a_-5 INCW-/0-- 4449\1 INCH TRIM CAP 3/16 INCH ACR·rLIC FASTENERS IiI ANGLE ALUMINUM - SUPPORT, WHITE PRECOAT ---- 3/16 INCH ACRYLIC rn CENTERS/1 INCH DEEP SLOAN LED.PRIMARY POWER IN CONDUIT TO WATER- 1/4 INCH SCREWS TIGk-IT J-BOX WITH SWITCH MATTE BLACK RETURN 1/4 INCW WEEP MOLE.2 FT e IN TRANSFERRED BY €__ DATE la IN A 'dug ROUGH- FINAL_82_PLANNING INSPECTION REQUIRED:NONE- NAME_4*»1¥*9*_(714)Qi-2.-254__ 'RETAIN PLANS FOR FUTURE REVISIONS.®CUBJECT TO ITEMS CHECKED AND CONDITE» ;ELOW O INTERIOR T{ ONLYO NO EXTERIOR ALTERATIONS/MODIFICATIONS O ALL ¥,ATERIALS TO MATCH EXISTING O SCREENING REQUIRED O SUBMIT LANDSCAPE PLANS ® ONE SET OF ILLUMINATED CHANNEL LETTERS CONDITIONS:SW 300 - 119 COLORS A 2441 WHITE ACRTUC B. 2119 ORANGE ACRYLIC C. 1125-12 BLACK. D. 3630-44 ORANGE E OPEN AREA F. 2025 BLACK ACRN'LIC LETTERS/CAPSULE LED.FOOTAGE 28 FT 6 IN imit©23 FT 4 IN 3e FT 4 IN TILT MAN - LOGO CAPSULE 9 INCH DEEP MATTE BLACK RETURNS WITH WHITE INTERIOR FINISH -WHITE PRECOAT BACK -3/16 INCH 2441 WHITE ACRYLIC FACE -HIGH-PERFORMANCE BLACK VINYL (FIRST SURFACE) -1 INCH BLACK JEWEUTE TRIM CAP -SLOAN V-SERIES WHITE LE. D. ILLUMINATION (#101269-UJLP-Me) -SLOAN 12ev MOD-ee POWER SUPPUES (#101501-MOD) - LETTER RETURN UTTLE CAESARS LETTERS 9 INCH DEEP MATTE BLACK RETURNS UJITH UJHITE INTERIOR FINISH -WHITE PRECOAT BACK -3/16 INCH 2119 ORANGE ACRYLIC FACE -WIGH-PERFORMANCE BLACK VINYL (FIRST SURFACE) -1 INCH BLACK JEUJEUTE TRIM CAP -SLOAN v-SERIES ORANGE LE.D. ILLUMINATION (#101269-UJLP-MS) -SLOAN 12ev MOD-ee POWER SUPPLIES (#101501-MOD) -REGISTERED TRADEMARK ® BLACK VIN'rL ON WHITE PRECOAT r- - TRIM CAP 1-5/16 INCH - ACRYLIC FACE 1 INCH BLACK TRIM CAP VINYL 1-1/8 CH BLACK - TRIMCAP LETTER FACE W/ BLACK VINYL OUTLINE BLACK VINYL OUTLINE Bk 3/16 INCH ACRYLIC LETTER CENTERS (CAP BACKS) SOLVENTWELDED TO TRIM CAP AREA OPEN LOGO FACE W/ 3/16 2119 ORANGE ACRYLIC LETTER FACE WITH BLACKVINYL OUTLINE 0 LOGO & LETTER FACE VINYL DETAIL PARTIAL SECTION/ISOMETRIC DETAILe EAGLE SIGNS 1028 EAST ACACIA STREET I ONTARIO, CA 91761 PHONE 909.923.30341 FAX: 909.923.3043 WWW.EAGLESIGNS.NET DATE: OCTOBER 7, 2013 SCALE: AS NOTED DRAWN BY: DS PROJECT NAME: LITTLE CAESARS ADDRESS:1730 E 17TH ST, STE D SANTAANA, CA This is an original unpublished drawing created by Eagle Signs. It is submitted for your FIRST REVISION personal use in conjunction with a project being planned for you by Eagle Signs, and shall not SECOND REVISION be reproduced, used byordisclosed to anyfirm or corporation for any purpose whatsoever THIRD REVISION withoutwritten permission. 96:Ing! O-Je ar..or o,her applicaole laral O]de€ Underwriters Laboraties Inc.. LISTED Em DRAWING NUMBER: LCSACA003 SHEET 1 OF 2 1 Ct. MFil V i ii it " 1-4, r 1130 At , b % 21 1730 At L..S d t 1 4 7 4=U il 2§ith 1 $1, St 9. .le •201• 1730 Ai 1730 Al .f PROPOSED ELEVATION f EAGLE SIGNS 1028 EAST ACACIA STREET i ONTARIO. CA 91761 PHONE: 909 923.3034 1 FAX: 909.923.3043 WWW.EAGLESIGNS.NET DATE: OCTOBER 7, 2013 SCALE: AS NOTED DRAWN BY: DS PROJECT NAME: LITTLE CAESARS ADDRESS:1730 E 17TH ST, STE D SANTAANA, CA This is an original unpublished drawing created by Eagle Signs. It is submitted for your FIRST REVISION personal use in conjunction with a projectbeing planned for you by Eagle Signs, and shall not SECOND REVISION be reproduced, used byordisclosed toanyfirm or corporation for any purpose whatsoever THIRD REVISION withoutwritten permission. Uum Underwriters Laboraties Inc.. LISTED DRAWING NUMBER: LCSACA003 SHEET 2 OF 2 PEA z hi »O %r /72 l L 0 2* gr 9 6/ jz In \0\80\10(11?80 7,0 0 3 03-2 WO R cy)=a)-O S. a c7 N (D L 9[lor€ X 2-0 ,Arh C-C 91-coam , & & S.o 3 M .., m Q C' 0} W c a) 08.-0ER<3 2 011,0, 0 0 0 CONSTR. -Wou- 21 3 & BrIOUS 000 . 6, 1,1,1, i 1 Yp ly W u # 19 lim c In m V Co Co f 0 Z 0 ON 33'l 30061 ED=S3A a.OEIW :=Illk:33:-==E=E,ECTF A al [E] 5. 3 R JR The approval of this plan and speclfications SHALL NEC NOT ha Jigld to permit nor be an approval of theviolatiton-br any provisions of ANY City Ordinanceor State Law.Approve¢' by 11 0 0.-21 1,1 j \0 ARRIAL Di ITY OF SANTA ANADEPARTMENT OF BUILDING SAFETY 3TR'(