HomeMy WebLinkAbout1218 W Cubbon St #2 - PlanCOVER PAGE FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-0 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA SCOPE OF WORK (3.960 kW DC, 2.610 kW AC) ARRAY LOCATION(S) PV-0 COVER PAGE PV-1,1.1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAIL PV-4 ELECTRICAL LINE ELECTRICAL PV-5 EQUIPMENT ELEVATION PV-6 WIRING CALCULATION PV-7 WARNING LABELS & PLACARDS PV-8+ EQUIPMENT SPECIFICATION AHJ: SANTA ANA (CITY), CALIFORNIA UTILITY: SCE HOUSE PHOTO SCALE: NTS VICINITY MAP PROJECT SITE GENERAL NOTES:SHEET INDEX COVER PAGE GOVERNING CODES ● ATTACHMENT - PEGASUS COMP MOUNT SCALE: NTS ·RAIL- PEGASUS RAIL ● MSP UPGRADE: NO ● MAIN BREAKER DERATE: NO ●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES ● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTERS ● (1) - 30A NON FUSED AC DISCONNECT SQUARE D DU221RB ● 1X BRANCH OF 9 CONNECTED IN PARALLEL 1) ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. 2) THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND UTILITY IS OBTAINED. 3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE LISTED BY 'UL' FOR THE TYPE OF APPLICATION AND 'UL' LABEL SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. 4)AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION. 5) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF NECESSARY. 6) ENPHASE DEVICES ARE WITHIN MANUFACTURER'S REQUIRED GUIDELINE, PV ARRAY DOES NOT EXCEED MAX DISTANCE OF 150'. 7) ALL ENSEMBLE EQUIPMENT MUST BE WITHIN 50' OF EACH OTHER. LE G E N D NEW PV MODULE FIRE SETBACK MICRO-INVERTER ROOF ATTACHMENT DIMENSIONS PROPERTY LINE RAFTER/TRUSS RAIL FENCE GATE JB JUNCTION BOX (NEW) CP COMBINER PANEL (NEW) ACD AC DISCONNECT UNFUSED (NEW) M METER MAIN COMBO (EXISTING) CONDUIT SSP SUB SERVICE PANEL (NEW) STC DC:(9) 440W = 3.960 kW STC AC:(9) 290W = 2.610 kW CEC AC:3.598 kW DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE. OCCUPANCY CLASS: R3 CONSTRUCTION TYPE:VB CBC/CRC EDITION:2022 9 MODULES- SYSTEM SIZE STC - (3.960 kW DC, 2.610 kW AC) 1218 W CUBBON ST, SANTA ANA, CA 92703, USA (33.735277, -117.883963) PHOTOVOLTAIC ROOF MOUNT SYSTEM ● (1) - ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C) ● 2022 CALIFORNIA RESIDENTIAL CODE (CRC) ● 2022 CALIFORNIA BUILDING CODE (CBC) ● 2022 CALIFORNIA MECHANICAL CODE (CMC) ● 2022 CALIFORNIA ELECTRICAL CODE (CEC) ● 2022 CALIFORNIA PLUMBING CODE (CPC) ● 2022 CALIFORNIA ENERGY CODE (ENERGY) ● 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) ● 2020 NATIONAL ELECTRICAL CODE (N ww w . L o y d W M a r t i n . c o m So l a r S t r u c t u r e s E n g i n e e r i n g #2 0 2 5 - 0 8 4 5 S t r u c t u r a l O n l y Ap r i l 1 , 2 0 2 5 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL ­2187 Bldg #101124171 & Elect #20186247 ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** 52' 14 0 ' - 5 " 14 0 ' - 5 " 52' M JB AC D CP SS P 5' - 3 " 17 ' - 8 " 7' - 8 " 2" 10'-1" 3' 8'-10"7'-6"10'-2" 6' - 3 " 9" 6' 10 ' - 1 " 4'6'-3" 3'-1" 7' - 6 " SITE PLAN SCALE: 1/64"= 1'0" W CUBBON ST SITE PLAN WITH ROOF PLAN FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-1 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE. (N) JUNCTION BOX (E) SHED NO ELECTRICAL (E) METER MAIN COMBO (N) VISIBLE LOCKABLE LABELED AC DISCONNECT (N) PV ARRAY (N) 3/4" OR GREATER FMC CONDUIT RUN THROUGH ATTIC LE G E N D NEW PV MODULE FIRE SETBACK MICRO-INVERTER ROOF ATTACHMENT DIMENSIONS PROPERTY LINE RAFTER/TRUSS RAIL FENCE GATE JB JUNCTION BOX (NEW) CP COMBINER PANEL (NEW) ACD AC DISCONNECT UNFUSED (NEW) M METER MAIN COMBO (EXISTING) CONDUIT SSP SUB SERVICE PANEL (NEW) ROOF 1 DR I V E W A Y PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E ROOF 2 (N) COMBINER PANEL ROOF ACCESS POINT WALKWAY (N) SUB SERVICE PANEL (N) ADU ROOF 3 ww w . L o y d W M a r t i n . c o m So l a r S t r u c t u r e s E n g i n e e r i n g #2 0 2 5 - 0 8 4 5 S t r u c t u r a l O n l y Ap r i l 1 , 2 0 2 5 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL ­2187 M JB AC D CP SS P ROOF PLAN WITH MODULES FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-2 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA PV PANELS (COUNT, AREA, WEIGHT): ● (9X) APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES (75.1" X 44.6", 52.9 LB) MICRO-INVERTERS (COUNT, WEIGHT): ●(9X) ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVETERS (2.43 LBS) MODULE AREA & WEIGHT CALCULATIONS ROOF PLANES: ● ATTACHMENT COUNT: 24 ● MOUNTING SYSTEM WEIGHT / MODULE: 1.5 LB ● MOUNTING SYSTEM WEIGHT: (9) 1.5 LB = 13.50 LB ● SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERETHE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ROOF ACCESS POINT DESIGN CRITERIA ● EXPOSURE CATEGORY = B ● WIND SPEED = 95 MPH ● SNOW LOAD = 0 PSF ROOF TYPE- COMP SHINGLE ROOF VENTS, SKYLIGHTS, WILL NOT BE COVERED UPON PV INSTALLATION ATTACHMENT SHEET FRONT OF HOUSE SCALE: 1/16" = 1'-0" NEW PANELS PANEL AREA PANEL WEIGHT MICRO-INVERTER WEIGHT TOTAL SYSTEM WEIGHT WEIGHT PER CONNECTION DISTRIBUTED LOAD (9) 2.43 = 21.87 LB 476.1 + 21.87 + 13.50 = 511.47 LB 511.47 LB / 24 = 21.31 LB 511.47 LB / 209.34 SF = 2.44 PSF (9) 75.1" x 44.6" = 209.34 SF (9) 52.9 = 476.10 LB (N) PV ARRAY W CUBBON ST BILL OF MATERIALS SOLAR PV MODULES MICRO INVERTERS ATTACHMENTS PEGASUS COMP MOUNT RAIL PEGASUS RAIL RAIL SPLICES RAIL SPLICES (FOR ABOVE)0 MID CLAMPS MID CLAMPS8 END CLAMPS END CLAMPS GROUNDING LUG GROUNDING LUG 20 5 APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER 9 9 24 7 AC DISCONNECT PV VISIBLE LOCKABLE LABELED DISCONNECT (30A UNFUSED 1PH 240VAC)2 ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C) BOXCOMBINER1 ROOF DESCRIPTION TABLE ROOF PLANE ROOF TILT ROOF AZIMUTH RAFTER SIZE RAFTER SPACING ATTACHMENT SPACING ROOF MATERIAL #1 18°72" O.C.2"X4"24" O.C.270° MODULES 5 #2 18°72" O.C.2"X4"24" O.C.180°2 #3 18°72" O.C.2"X4"24" O.C.90°2 COMP SHINGLE COMP SHINGLE COMP SHINGLE LE G E N D NEW PV MODULE FIRE SETBACK MICRO-INVERTER ROOF ATTACHMENT DIMENSIONS PROPERTY LINE RAFTER/TRUSS RAIL FENCE GATE JB JUNCTION BOX (NEW) CP COMBINER PANEL (NEW) ACD AC DISCONNECT UNFUSED (NEW) M METER MAIN COMBO (EXISTING) CONDUIT SSP SUB SERVICE PANEL (NEW) ww w . L o y d W M a r t i n . c o m So l a r S t r u c t u r e s E n g i n e e r i n g #2 0 2 5 - 0 8 4 5 S t r u c t u r a l O n l y Ap r i l 1 , 2 0 2 5 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL ­2187 PEGASUS RAIL PEGASUS COMP MOUNT (L-FOOT) SOLAR MODULE PEGASUS SHINGLE FLASHING RAFTERS. WOOD SHEATHING 5/16"x4 1/2" STAINLESS STEEL LAG SCREW EMBEDMENT DEPTH MINIMUM 2.5 FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-3 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA ATTACHMENT DETAILS ATTACHMENT DETAIL (ENLARGED SECTION VIEW) SCALE: NTS ATTACHMENT DETAIL SCALE: NTS REFER TO ROOF DESCRIPTION TABLE IN PV-2 FOR MOUNTING PLANE DETAILS COMP SHINGLE ROOF SOLAR MODULE WOOD SHEATHING PEGASUS RAILS 5/16"X4 1/2" STAINLESS STEEL LAG SCREW WITH EMBEDMENT DEPTH MINIMUM 2.5 PEGASUS COMP MOUNT RAFTERS PEGASUS COMP MOUNT (L-FOOT) ww w . L o y d W M a r t i n . c o m So l a r S t r u c t u r e s E n g i n e e r i n g #2 0 2 5 - 0 8 4 5 S t r u c t u r a l O n l y Ap r i l 1 , 2 0 2 5 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL ­2187 NOTE: Engineer of Record assumes that all structural components of the existing building were permitted and met the requirements of the Building Code at the time of construction. Solar Contractor shall field verify that the roof framing is in its existing permitted condition and capable of supporting required live loads. Framing specified on solar plans shall be assumed to be minimum size and spacing, actual framing may be different. 2 (N) AC DISCONNECT VISIBLE,LOCKABLE AND LABELED SQUARE D DU221RB 30A NON-FUSIBLE 240VAC NEMA-3R, UL LISTED OR EQUIVALENT L1 L2 N G L1 L2 N G 2 9 MICROINVERTERS IN BRANCH CIRCUIT 1 G 9 -APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES 9 - ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER(240V) - MOUNTED UNDER EACH PANEL (690.14(D)) INTEGRATED GROUNDING WIRE N G ENVOY IQ (REVENUE GRADE METER) L2 L1 (N) JUNCTION BOX ROOFTOP 600 V, NEMA 3-R UL LISTED 20A/2P 15A/2PA 1 (N) DEDICATED PHOTOVOLTAIC SYSTEM ENPHASE IQ COMBINER 5/5C X-IQ-AM1-240-5/5C NEMA 3R, UL LISTED,125A RATED N GEC M EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF.NEC 250.52, 250.53(A) (E) MAIN BREAKER TO HOUSE 240 V, 200A/2P G TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V L2 L1 N BACKFEED BREAKER INTERCONNECTION AT MAIN PANEL PER ART. NEC 705.12(B)(3)(2) N G (N)PV 30A/2P (E) SUB SERVICE PANEL 200A RATED EXISTING WIRES 200A/2P FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-4 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA ELECTRICAL LINE &CALCS. ELECTRICAL THREE LINE DIAGRAM SCALE: NTS &CALCS. EXTREME CASE MODULE OUTPUT (APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES) AC wire details Tag Line Neutral Ground Min EMT/PVC 1 12 AWG (Q-Cable)06 AWG BARE (NOT IN CONDUIT) 2 10 AWG THWN-2 10 AWG THWN-2 (2)10 AWG THWN-2 10 AWG THWN-2 - - -A 3/4 in EMT 3/4 in EMT 10 AWG THWN-2 Isc(25°C) = 13.73A, Tisc = 0.054%/°C Isc(T) = Isc(25°C) x [1 + (0.054/100) x (T-25°C)] Isc(-2°C) = 13.53A, Isc(31°C) = 13.77A Voc(25°C) = 41.02V, Tvoc = -0.27%/°C Voc(T) = Voc(25°C) x [1 + (-0.27/100) x (T-25°C)] Voc(-2°C) = 44.01V, Voc(31°C) = 40.36V SYSTEM SUMMARY STC (3.960 kW DC / 2.610 kW AC) STC DC:(9) 440W = 3.960 kW STC AC:(9) 290W = 2.610 kW ●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES ● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER ELECTRICAL NOTES 1)ALL GROUNDING TO COMPLY WITH CEC 690.47. 2)ALL TERMINALS SHALL BE MIN. 75°C RATED. 3)IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A). 4)IQ COMBINER 5/5C REQUIRES ENPHASE HOLD DOWN KIT X-IQ-NA-HD-125A. DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE. NOTE: SPLICING OF THE WIRE-TYPE GROUNDING ELECTRODE SHALL BE PERMITTED ONLY BY IRREVERSIBLE COMPRESSION-TYPE CONNECTORS LISTED AS GROUNDING AND BONDING EQUIPMENT OR BY THE EXOTHERMIC WELDING METAL WATER PIPING SYSTEM INSTALLED IN OR ATTACHED TO A BUILDING OR STRUCTURE SHALL BE BONDED PER NEC TABLE 250.66 AND 250.104(A)(1). •NEW ELECTRICAL SHALL BE LOCATED AT LEAST THREE (3) FEET FROM GAS METER OR GAS SHUT- OFF VALVES. UPC1208.7.1; NEC 110.26.” •GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED PER NEC 250.66.● 1X BRANCH OF 9 CONNECTED IN PARALLEL INTERCONNECTION 120% RULE - CEC 705.12(B)(3)(2) UTILITY FEED + SOLAR BACKFEED 200A + 20A = 220A BUSS RATING x 120% 200A x 120% = 240A (2) FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-5 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA EAST WALL FACING ELEVATION EQUIPMENT ELEVATION EQUIPMENT ELEVATION SCALE: NTS NEW ELECTRICAL GUTTERNEW ELECTRICAL GUTTER (E) METER MAIN COMBO (N) AC DISCONNECT FROM ROOF TOP ENPHASE (N) IQ COMBINER 5/5C (E) SUB SERVICE PANEL ON MAIN HOUSE ON ADU FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-6 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA WIRING CALCULATION WIRING CALCULATIONS SCALE: NTS SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES VMP 33.72V IMP 13.05A VOC 41.02V ISC 13.73A TEMP. COEFF. VOC -0.27%/°C MODULE DIMENSION 75.1(L) x 44.6(W) PANEL WATTAGE 440W Inverter Ratings Inverter Make/Model ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] Max DC Volt Rating 60V Max con output Power 290W Max Nominal Voltage 240V Max AC Current 1.21A Max OCPD Rating 20A EXTREME CASE MODULE OUTPUT (APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES) Isc(25°C) = 13.73A, Tisc = 0.054%/°C Isc(T) = Isc(25°C) x [1 + (0.054/100) x (T-25°C)] Isc(-2°C) = 13.53A, Isc(31°C) = 13.77A Voc(25°C) = 41.02V, Tvoc = -0.27%/°C Voc(T) = Voc(25°C) x [1 + (-0.27/100) x (T-25°C)] Voc(-2°C) = 44.01V, Voc(31°C) = 40.36V ● 1X BRANCH OF 9 CONNECTED IN PARALLEL SYSTEM SUMMARY STC (3.960 kW DC / 2.610 kW AC) STC DC:(9) 440W = 3.960 kW STC AC:(9) 290W = 2.610 kW ●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES ● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER ELECTRICAL NOTES 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT. 3) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 4) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 5) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 6) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 7) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 8) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 9) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. 10) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. 11) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). 12) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A). 13) IQ COMBINER 5/5C REQUIRES ENPHASE HOLD DOWN KIT X-IQ-NA-HD-125A. AC wire details Tag Nominal Voltage Expected max temp Adjusted ampacity (ampacity x temp derate x conduit fill derate) Conductor & neutral size A 30 x 1 x 1 = 30.00 A 12 AWG (Q-Cable) 10 AWG THWN-2 #Modules 9 91 240 V 240 V Backfeed *1.25 /cond.set 13.61 A Min OCPD 13.61 A 20 A 20 A Conductor sets 1 1 ccConductors /conduit - 2 31 Conductor metal Cu Cu Max length 30 ft 15 ft V drop Min EMT/PVC size 0.47 0.15 EGC size (Cu) 06 AWG BARE (NOT IN CONDUIT) 10 AWG THWN-2 - 3/4 in EMT31 10 AWG THWN-22240 V 12.10 A 20 A 1 2 Cu 15 ft10 AWG THWN-2 3/4 in EMT31 35 x 1 x 1= 35.00 A 35 x 1 x 1 = 35.00 A9 0.15 M JB ACDCP SSP WARNING LABELS FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-7 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA & PLACARD CAUTION: MULTIPLE SOURCES OF POWER ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTERS, AC DISCONNECTS, AC COMBINER BOXES CODE REF: CEC 2022 - 690.13(B) WARNING SOLAR SYSTEM CONNECTED AND ENERGISED LABEL LOCATION: UTILITY METER CODE REF: CEC 2022 - 690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: AC DISCONNECTS FOR UTILITY ACCESS CODE REF: CEC 2022 - 690.13(B) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE (MSP OR AC DISCONNECT IF LINE SIDE TAP), AND WHEREVER REQUIRED BY AHJ (INVERTERS, DC DISCONNECTS, OTHER) CODE REF: CEC 2022 - 690.56(C)(2) POWER SOURCE OUTPUT CONNECTION WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: FIRST BACKFEED BREAKER (MSP/SUBPANEL) IF NO LINE SIDE TAP CODE REF: CEC 2022 - 705.12(B)(3)(2), MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 10.89 AMPS 240.0 VAC PV SYSTEM DISCONNECT LABEL LOCATION: INTERCONNECTION Placard (MSP BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC DISCONNECTS CODE REF: CEC 2022 - 690.54 PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: INTERCONNECTION Placard (MSP BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC DISCONNECTS CODE REF: CEC 2022 - 690.13(B) WARNING! TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL LABEL LOCATION: MSP CODE REF: CEC 2022 - 110.27(C) CAUTION: MULTIPLE POWER SOURCES LABEL LOCATION: MSP CODE REF: CEC 2022 - 690.56(B), CEC 2022 - 705.10 SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. NOTICE PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL LABEL LOCATION: LOAD CENTER [Only use when applicable for PV load center] ! Follow all safety procedures and wear proper PPE in accordance to NFPA 70E, Failure to comply can result in serious injury or death. Arc Flash and Shock Hazard Appropriate PPE Required WARNING SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION: INTERCONNECTION POINT (MSP OR AC DISCONNECT IF LINE SIDE TAP) CODE REF: CEC 2022 - 690.56(C) NOTES AND SPECIFICATIONS 1) SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF CEC 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. 2) SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. 3) LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. 4) LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 5) SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4 - 2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. 6) DO NOT COVER EXISTING MANUFACTURER LABELS. LABEL LOCATION: MSP CODE REF: CEC 2022 - 705.10, CEC 2022 - 710.10 (E) METER MAIN COMBO (N) COMBINER PANEL (N) VISIBLE LOCKABLE LABELED AC DISCONNECT (N) SUB SERVICE PANEL FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-10 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA EQUIPMENT SPECIFICATION ww w . L o y d W M a r t i n . c o m So l a r S t r u c t u r e s E n g i n e e r i n g #2 0 2 5 - 0 8 4 5 S t r u c t u r a l O n l y Ap r i l 1 , 2 0 2 5 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL ­2187 FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-11 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA EQUIPMENT SPECIFICATION ww w . L o y d W M a r t i n . c o m So l a r S t r u c t u r e s E n g i n e e r i n g #2 0 2 5 - 0 8 4 5 S t r u c t u r a l O n l y Ap r i l 1 , 2 0 2 5 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL ­2187 FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , CA 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-12 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA EQUIPMENT SPECIFICATION FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-8 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA EQUIPMENT SPECIFICATION FR A N C I S C O G U T I E R R E Z 12 1 8 W C U B B O N S T # 2 , SA N T A A N A , C A 9 2 7 0 3 , U S A REVDATEDESCRIPTION REVISIONS HOMEOWNER INFO AP N : 0 1 0 2 7 2 0 7 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-9 SIGNATURE & SEAL CONTRACTOR: MY SMART HOUSE ADDRESS: 39809 AVENIDA ACACIAS, UNIT D MURRIETA, CA 92563 PHONE: 8884453020 LICENSE #: C-10 1095569 JOSE EMILIO BAHENA EQUIPMENT SPECIFICATION To Whom It May Concern, This letter serves to confirm I have chosen to have my system installed by My Smart House for the work being performed at 1218 W Cubbon St, Santa Ana, CA 92703. Thank you, Francisco Gutierrez __________________________ Signature __________________________ Date Docusign Envelope ID: F62F7D04-6BC4-42DE-BFAF-3BB0C530C9E0 6/27/2025 Certificate Of Completion Envelope Id: F62F7D04-6BC4-42DE-BFAF-3BB0C530C9E0 Status: Completed Subject: Complete with Docusign: HOMEOWNER AUTHORIZATION LETTER.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 My Smart House LLC AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 39809 Avendia Acacias Ste D Murrieta, CA 92563 ops@my-smarthouse.com IP Address: 47.144.225.4 Record Tracking Status: Original 6/27/2025 10:58:27 AM Holder: My Smart House LLC ops@my-smarthouse.com Location: DocuSign Signer Events Signature Timestamp FRANCISCO GUTIERREZ frankh9g@yahoo.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 2603:8001:3f00:9c7:548e:45cc:56d7:17ab Signed using mobile Sent: 6/27/2025 10:59:44 AM Viewed: 6/27/2025 11:02:31 AM Signed: 6/27/2025 11:03:14 AM Electronic Record and Signature Disclosure: Accepted: 6/27/2025 11:02:31 AM ID: 4c919260-d4d5-4883-8098-ad04db2ecf53 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 6/27/2025 10:59:44 AM Certified Delivered Security Checked 6/27/2025 11:02:31 AM Signing Complete Security Checked 6/27/2025 11:03:14 AM Completed Security Checked 6/27/2025 11:03:14 AM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, MSH (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 2/6/2020 1:48:36 PM Parties agreed to: FRANCISCO GUTIERREZ Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact MSH: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: britney@my-smarthouse.com To advise MSH of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at britney@my-smarthouse.com and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from MSH To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to britney@my-smarthouse.com and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with MSH To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to britney@my-smarthouse.com and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify MSH as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by MSH during the course of your relationship with MSH. Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org applications@my-smarthouse.com 951-462-5890 Jose Bahena My Smart House 1095569 1218 W CUBBON ST, SANTA ANA, CA 92703 6/24/2025 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. Expedited Permit Process for PV Systems — Micro-Inverter 2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan             E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone:One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram Structural Calculations for a Roof Mounted Solar Photovoltaic System for: Francisco Gutierrez 1218 W Cubbon St Santa Ana, CA 92703 Applicable Codes: 2022 California Building Code, 2022 California Electric Code, 2022 California Mechanical Code, American Society of Civil Engineers Standard ASCE 7-16 Minimum Design Loads for Buildings and Other Structures, American Wood Council 2018 National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adopted by reference or enacted by law. Assumed Design Parameters: The existing structure has been built under a building permit and is in its original condition. The existing roof structure is capable of its code required live load and the ability of the roof structure to support live loads has not been substantially reduced by the age of the structure, termites or mold, or unauthorized modifications to the existing structure. Solar Energy Contractor shall make an inspection of the existing roof framing system prior to installation of the roof mounted solar energy system to verify that the existing roof is capable of supporting minimum roof live loads. Assumed Design Parameters: All 2x members are grade Douglas Fir #2 or better All 4X members are grade Douglas Fir #1 or better All Roof Connectors are Simpson Strong-Tie or Equal All Concrete Foundations are f'c = 2500 psi or stronger Sht # 1 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Original Structure was built to the Type-V Wood Framed Standards of the Applicable Building Code at the time of Construction. Exp. 3-31-19 C L ­2187 Note to Building Official: Based upon a review of the proposed plans I am confident that the existing roof framing system is capable of safely supporting the additional loads caused by the new solar photovoltaic energy system. The contractor shall field verify that the existing roof structure is in its original permited condition and verify that it can support the normal code required roof live loads. Attached in this package are several calculations showing that the roof members can support the additional weight of the solar array. Furthermore, an analysis of the solar array's support for wind forces and a seismic analysis of the existing structure are also included. Check Existing 2X4 Roof Rafters @ 24" O.C.: (Assume max rafters span = 7.83 ft.) w =30 psf x 2 ft. = 60 plf Total load on rafters = 60 plf x 7.83 ft. = 470 lbs Sht # 2 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com 7.83' Exp. 3-31-19 C L ­2187 Check Existing 2X4 Roof Rafters @ 24" O.C.: Snow Load =0 psf Dead Load =14 psf Live Load =16 psf WDL + LL =30 psf x 2 ft. = 60 plf WDL =14 psf x 2 ft. = 28 plf w =30 psf x 2 ft. = 60 plf Total load on rafters =( 28 plf x 7.83 ft ) + ( 6' x 2.75' x 3 psf x 2 ) + ( 6' x 1.65' x 3 psf x 1 ) =348 lbs < 470 lbs OK OK. Per 2022 California Existing Building Code Section 503.3 Alterations Check attachment of Support to Existing Structure for Wind Uplift CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2. NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA: FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT BE LESS THAN ONE-THIRD ITS LENGTH. EFFECTIVE AREA = 15 SQ FT Sht # 3 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com % CHANGE =348 lbs - 470 lbs x 100 =-26% < 5% OK470 lbs Exp. 3-31-19 C L ­2187 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Tributary Area to Each Solar Mount = 6 ft. x 2.75 ft. = 16.5 sq. ft. ( Max ) Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C): p = q h (GC p )(γ E )(γ a )Eq'n 29.4-7 ASCE 7-16 q h = 0.00256 K z K zt K d K e V 2 Eq'n 26.10-1 ASCE 7-16 Note: K z =velocity pressure coefficient Section 29.10.1 ASCE 7-16 K z =0.9 (Exposure C, Height = 20 ft or less) K zt =Topographical Factor = 1.0 K d =Wind Directionality Factor = 0.85 K e =Ground Elevation Factor = 1.0 V =130 mph q h =0.00256 (0.9) (1.0) (0.85) (1.0) (130)² q h =33.1 psf GC p =-2.0 (Zone 2 ; Effective Area = 15 sq. ft. ) γ E =Exposure Factor = 1.5 γ a =Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4-8 ASCE 7-16 p = q h (GC p )(γ E )(γ a ) p = 33.1 psf (-2.0) (1.5) (0.7) = 69.5 psf Sht # 4 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Exp. 3-31-19 C L ­2187 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Nominal (Unfactored) Uplift at each support = 69.5 psf x 16.5 sq. ft. = 1146.75 lbs Note: Section 2.4.1 of ASCE 7-16, Basic Load Combinations for Allowable Stress Design. Note: Applicable Load Combination #5 (D + 0.6W) Design (Factored) Uplift at each support = 0.6 x 1146.75 lbs = 688 lbs Load per lag screw = 688 lbs / 1 = 688 lbs Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below according to the 2018 NDS. W ' = W x Cd x Ct Table 10.3.1 2018 NDS where W = 266 lbs / in. of embedment per Table 12.2a Cd = 1.6 per Table 2.3.2 of 2018 NDS Ct = 1.0 per Table 2.3.3 of 2018 NDS W' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 688 lbs OK Sht # 5 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Use Support connected to 2x Min. Roof Member w/ (1) 5/16" x 3.5" lag screws per connection minimum. Exp. 3-31-19 C L ­2187 Check Seismic load due to added dead load of photovoltaic system. Determine Seismic Weight of Existing Building: Effective Existing Seismic Weight Area of (E) Building =Approximately 700 Sq. ft Approximate Effective =700 sq. ft. x 30 psf ave. = 21,000 LBS Seismic Weight DETERMINE BASE SHEAR V = Cs W EQ'N 12.8-1 ASCE 7-16 EQ'N 12.8-2 ASCE 7-16 R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1 R =6.5 WOOD SHEAR WALLS Ie = 1.0 IMPORTANCE FACTOR SDS = 2/3 x SMS SMS = FA x SS SMS = 1.2 x 1.5 = 1.8 SDS = 2/3 x 1.8 = 1.2 Cs ==0.185 EQ'N 12.8-2 ASCE 7-16 Sht # 6 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Cs =SDS R Ie SDS R Ie Exp. 3-31-19 C L ­2187 EXISTING BASE SHEAR V = 0.185 x 21,000 LBS = 3,885 LBS DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING SEISMIC =21,000 LBS WEIGHT NEW SOLAR ARRAY =3 PSF x 9 PANELS x 5.5' x 3.3' = 491 LBS NEW SEISMIC =21,000 LBS + 491 LBS = 21,491 LBS WEIGHT THEREFORE NEW BASE SHEAR: V = 0.185 x 21,491 = 3,976 LBS EQ'N 12.8-1 ASCE 7-16 OK. PER ASCE 7-16 SECTION 11B.4 ALTERATIONS EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT FROM ANALYSIS SINCE NEW SEISMIC FORCE IS LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE Sht # 7 of 7 2025-0845 Smart House Francisco Gutierrez April 1, 2025       Loyd W. Martin Professional Engineer, Inc.       9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 "Alterations may be made to any structure without requiring the existing structure to comply with this standard, provided that the alterations comply with the requirements for a new structure. Alterations that increase the seismic force in any existing structural element by more than 10% or decrease the design strength of any existing structural element to resist seismic forces by more than 10% shall not be permitted unless the entire seismic force- resisting system is determined to comply with this standard for a new structure." End of Calculations Email: loydwmartin@gmail.com www.loydwmartin.com % CHANGE =3,976 LBS - 3,885 LBS x 100 = 2.3 % < 10 % OK3,885 LBS Exp. 3-31-19 C L ­2187