REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-0
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
SCOPE OF WORK (3.960 kW DC, 2.610 kW AC)
ARRAY LOCATION(S)
PV-0 COVER PAGE
PV-1,1.1 SITE PLAN WITH ROOF PLAN
PV-2 ROOF PLAN WITH MODULES
PV-3 ATTACHMENT DETAIL
PV-4 ELECTRICAL LINE ELECTRICAL
PV-5 EQUIPMENT ELEVATION
PV-6 WIRING CALCULATION
PV-7 WARNING LABELS & PLACARDS
PV-8+ EQUIPMENT SPECIFICATION
AHJ: SANTA ANA (CITY), CALIFORNIA
UTILITY: SCE
HOUSE PHOTO
SCALE: NTS
VICINITY MAP
PROJECT SITE
GENERAL NOTES:SHEET INDEX
COVER PAGE
GOVERNING CODES
● ATTACHMENT - PEGASUS COMP MOUNT
SCALE: NTS
·RAIL- PEGASUS RAIL
● MSP UPGRADE: NO
● MAIN BREAKER DERATE: NO
●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES
● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTERS
● (1) - 30A NON FUSED AC DISCONNECT SQUARE D DU221RB
● 1X BRANCH OF 9 CONNECTED IN PARALLEL
1) ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND
LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO ACCOMMODATE
CONDUCTORS SHOWN.
2) THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND UTILITY IS OBTAINED.
3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE
THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE
WEATHERPROOF AND SHALL BE LISTED BY 'UL' FOR THE TYPE OF
APPLICATION AND 'UL' LABEL SHALL APPEAR ON ALL ELECTRICAL
EQUIPMENT.
4)AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF
THE ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION.
5) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL
GROUNDING ELECTRODE CONDUCTOR IF NECESSARY.
6) ENPHASE DEVICES ARE WITHIN MANUFACTURER'S REQUIRED GUIDELINE,
PV ARRAY DOES NOT EXCEED MAX DISTANCE OF 150'.
7) ALL ENSEMBLE EQUIPMENT MUST BE WITHIN 50' OF EACH OTHER.
LE
G
E
N
D
NEW PV MODULE
FIRE SETBACK
MICRO-INVERTER
ROOF ATTACHMENT
DIMENSIONS
PROPERTY LINE
RAFTER/TRUSS
RAIL
FENCE
GATE
JB JUNCTION BOX
(NEW)
CP COMBINER PANEL
(NEW)
ACD AC DISCONNECT UNFUSED
(NEW)
M METER MAIN COMBO
(EXISTING)
CONDUIT
SSP SUB SERVICE PANEL
(NEW)
STC DC:(9) 440W = 3.960 kW
STC AC:(9) 290W = 2.610 kW
CEC AC:3.598 kW
DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH
EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216
WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE.
OCCUPANCY CLASS: R3
CONSTRUCTION TYPE:VB
CBC/CRC EDITION:2022
9 MODULES- SYSTEM SIZE STC - (3.960 kW DC, 2.610 kW AC)
1218 W CUBBON ST, SANTA ANA, CA 92703, USA (33.735277, -117.883963)
PHOTOVOLTAIC ROOF MOUNT SYSTEM
● (1) - ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C)
● 2022 CALIFORNIA RESIDENTIAL CODE (CRC)
● 2022 CALIFORNIA BUILDING CODE (CBC)
● 2022 CALIFORNIA MECHANICAL CODE (CMC)
● 2022 CALIFORNIA ELECTRICAL CODE (CEC)
● 2022 CALIFORNIA PLUMBING CODE (CPC)
● 2022 CALIFORNIA ENERGY CODE (ENERGY)
● 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN)
● 2020 NATIONAL ELECTRICAL CODE (N
ww
w
.
L
o
y
d
W
M
a
r
t
i
n
.
c
o
m
So
l
a
r
S
t
r
u
c
t
u
r
e
s
E
n
g
i
n
e
e
r
i
n
g
#2
0
2
5
-
0
8
4
5
S
t
r
u
c
t
u
r
a
l
O
n
l
y
Ap
r
i
l
1
,
2
0
2
5
Exp. 3-31-19
No. C58724 NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
2187
Bldg #101124171 & Elect #20186247
***The scope of the plans is for the
installation of the solar photovoltaic system
only and the approval is subject to
compliance with all applicable city and state
codes and regulations regarding construction.
The approval of the plans does not constitute
any certification of the accuracy,
completeness, or building permit status of the
existing buildings and structures as shown.***
52'
14
0
'
-
5
"
14
0
'
-
5
"
52'
M
JB
AC
D
CP
SS
P
5'
-
3
"
17
'
-
8
"
7'
-
8
"
2"
10'-1"
3'
8'-10"7'-6"10'-2"
6'
-
3
"
9"
6'
10
'
-
1
"
4'6'-3"
3'-1"
7'
-
6
"
SITE PLAN
SCALE: 1/64"= 1'0"
W CUBBON ST
SITE PLAN WITH
ROOF PLAN
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-1
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH
EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216
WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE.
(N) JUNCTION BOX
(E) SHED
NO ELECTRICAL
(E) METER MAIN COMBO
(N) VISIBLE LOCKABLE
LABELED AC DISCONNECT
(N) PV ARRAY
(N) 3/4" OR GREATER
FMC CONDUIT RUN
THROUGH ATTIC
LE
G
E
N
D
NEW PV MODULE
FIRE SETBACK
MICRO-INVERTER
ROOF ATTACHMENT
DIMENSIONS
PROPERTY LINE
RAFTER/TRUSS
RAIL
FENCE
GATE
JB JUNCTION BOX
(NEW)
CP COMBINER PANEL
(NEW)
ACD AC DISCONNECT UNFUSED
(NEW)
M METER MAIN COMBO
(EXISTING)
CONDUIT
SSP SUB SERVICE PANEL
(NEW)
ROOF 1
DR
I
V
E
W
A
Y
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE PROPERTY LINE
PROPERTY LINE PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
ROOF 2
(N) COMBINER PANEL
ROOF ACCESS POINT
WALKWAY
(N) SUB SERVICE PANEL
(N) ADU
ROOF 3
ww
w
.
L
o
y
d
W
M
a
r
t
i
n
.
c
o
m
So
l
a
r
S
t
r
u
c
t
u
r
e
s
E
n
g
i
n
e
e
r
i
n
g
#2
0
2
5
-
0
8
4
5
S
t
r
u
c
t
u
r
a
l
O
n
l
y
Ap
r
i
l
1
,
2
0
2
5
Exp. 3-31-19
No. C58724 NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
2187
M
JB
AC
D
CP
SS
P
ROOF PLAN
WITH MODULES
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-2
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
PV PANELS (COUNT, AREA, WEIGHT):
● (9X) APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES (75.1" X 44.6", 52.9 LB)
MICRO-INVERTERS (COUNT, WEIGHT):
●(9X) ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVETERS (2.43 LBS)
MODULE AREA & WEIGHT CALCULATIONS
ROOF PLANES:
● ATTACHMENT COUNT: 24
● MOUNTING SYSTEM WEIGHT / MODULE: 1.5 LB
● MOUNTING SYSTEM WEIGHT: (9) 1.5 LB = 13.50 LB
● SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF
GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND
LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS
WHERETHE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD
OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.
ROOF ACCESS POINT
DESIGN CRITERIA
● EXPOSURE CATEGORY = B
● WIND SPEED = 95 MPH
● SNOW LOAD = 0 PSF
ROOF TYPE- COMP SHINGLE
ROOF VENTS, SKYLIGHTS,
WILL NOT BE COVERED
UPON PV INSTALLATION
ATTACHMENT SHEET
FRONT OF HOUSE
SCALE: 1/16" = 1'-0"
NEW PANELS
PANEL AREA
PANEL WEIGHT
MICRO-INVERTER WEIGHT
TOTAL SYSTEM WEIGHT
WEIGHT PER CONNECTION
DISTRIBUTED LOAD
(9) 2.43 = 21.87 LB
476.1 + 21.87 + 13.50 = 511.47 LB
511.47 LB / 24 = 21.31 LB
511.47 LB / 209.34 SF = 2.44 PSF
(9) 75.1" x 44.6" = 209.34 SF
(9) 52.9 = 476.10 LB
(N) PV ARRAY
W CUBBON ST
BILL OF MATERIALS
SOLAR PV MODULES
MICRO INVERTERS
ATTACHMENTS PEGASUS COMP MOUNT
RAIL PEGASUS RAIL
RAIL SPLICES RAIL SPLICES (FOR ABOVE)0
MID CLAMPS MID CLAMPS8
END CLAMPS END CLAMPS
GROUNDING LUG GROUNDING LUG
20
5
APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES
ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER
9
9
24
7
AC DISCONNECT PV VISIBLE LOCKABLE LABELED DISCONNECT
(30A UNFUSED 1PH 240VAC)2
ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C) BOXCOMBINER1
ROOF DESCRIPTION TABLE
ROOF
PLANE
ROOF
TILT
ROOF
AZIMUTH
RAFTER
SIZE
RAFTER
SPACING
ATTACHMENT
SPACING ROOF MATERIAL
#1 18°72" O.C.2"X4"24" O.C.270°
MODULES
5
#2 18°72" O.C.2"X4"24" O.C.180°2
#3 18°72" O.C.2"X4"24" O.C.90°2
COMP SHINGLE
COMP SHINGLE
COMP SHINGLE
LE
G
E
N
D
NEW PV MODULE
FIRE SETBACK
MICRO-INVERTER
ROOF ATTACHMENT
DIMENSIONS
PROPERTY LINE
RAFTER/TRUSS
RAIL
FENCE
GATE
JB JUNCTION BOX
(NEW)
CP COMBINER PANEL
(NEW)
ACD AC DISCONNECT UNFUSED
(NEW)
M METER MAIN COMBO
(EXISTING)
CONDUIT
SSP SUB SERVICE PANEL
(NEW)
ww
w
.
L
o
y
d
W
M
a
r
t
i
n
.
c
o
m
So
l
a
r
S
t
r
u
c
t
u
r
e
s
E
n
g
i
n
e
e
r
i
n
g
#2
0
2
5
-
0
8
4
5
S
t
r
u
c
t
u
r
a
l
O
n
l
y
Ap
r
i
l
1
,
2
0
2
5
Exp. 3-31-19
No. C58724 NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
2187
PEGASUS RAIL
PEGASUS COMP MOUNT
(L-FOOT)
SOLAR MODULE
PEGASUS
SHINGLE FLASHING
RAFTERS.
WOOD SHEATHING
5/16"x4 1/2" STAINLESS STEEL
LAG SCREW EMBEDMENT
DEPTH MINIMUM 2.5
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-3
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
ATTACHMENT
DETAILS
ATTACHMENT DETAIL (ENLARGED SECTION VIEW)
SCALE: NTS
ATTACHMENT DETAIL
SCALE: NTS
REFER TO ROOF DESCRIPTION TABLE IN PV-2
FOR MOUNTING PLANE DETAILS
COMP SHINGLE ROOF
SOLAR MODULE
WOOD SHEATHING
PEGASUS RAILS
5/16"X4 1/2" STAINLESS
STEEL LAG SCREW WITH
EMBEDMENT DEPTH
MINIMUM 2.5
PEGASUS COMP MOUNT
RAFTERS
PEGASUS COMP MOUNT
(L-FOOT)
ww
w
.
L
o
y
d
W
M
a
r
t
i
n
.
c
o
m
So
l
a
r
S
t
r
u
c
t
u
r
e
s
E
n
g
i
n
e
e
r
i
n
g
#2
0
2
5
-
0
8
4
5
S
t
r
u
c
t
u
r
a
l
O
n
l
y
Ap
r
i
l
1
,
2
0
2
5
Exp. 3-31-19
No. C58724 NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
2187
NOTE:
Engineer of Record assumes that all structural components of the existing building were
permitted and met the requirements of the Building Code at the time of construction.
Solar Contractor shall field verify that the roof framing is in its existing permitted
condition and capable of supporting required live loads. Framing specified on solar plans
shall be assumed to be minimum size and spacing, actual framing may be different.
2
(N) AC DISCONNECT
VISIBLE,LOCKABLE AND
LABELED SQUARE D
DU221RB 30A NON-FUSIBLE
240VAC NEMA-3R, UL
LISTED OR EQUIVALENT
L1
L2
N
G
L1
L2
N
G
2
9 MICROINVERTERS IN BRANCH CIRCUIT 1
G
9 -APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES
9 - ENPHASE ENERGY INC. IQ8PLUS-72-M-US
[240V] MICROINVERTER(240V) - MOUNTED
UNDER
EACH PANEL (690.14(D))
INTEGRATED GROUNDING WIRE
N
G
ENVOY IQ
(REVENUE GRADE METER)
L2
L1
(N) JUNCTION BOX
ROOFTOP
600 V, NEMA 3-R
UL LISTED
20A/2P
15A/2PA
1
(N) DEDICATED PHOTOVOLTAIC
SYSTEM ENPHASE IQ COMBINER 5/5C
X-IQ-AM1-240-5/5C NEMA 3R, UL
LISTED,125A RATED
N
GEC
M
EXISTING GROUNDING
ELECTRODE SYSTEM
TO EARTH
REF.NEC 250.52,
250.53(A)
(E) MAIN BREAKER TO
HOUSE 240 V, 200A/2P
G
TO UTILITY GRID
(E) BI-DIRECTIONAL UTILITY
METER 1-PHASE, 3-W,
120V/240V
L2
L1
N
BACKFEED BREAKER
INTERCONNECTION AT
MAIN PANEL PER ART.
NEC 705.12(B)(3)(2)
N
G
(N)PV
30A/2P
(E) SUB SERVICE PANEL
200A RATED
EXISTING WIRES
200A/2P
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-4
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
ELECTRICAL LINE
&CALCS.
ELECTRICAL THREE LINE DIAGRAM
SCALE: NTS
&CALCS.
EXTREME CASE MODULE OUTPUT
(APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES)
AC wire details
Tag Line Neutral Ground Min EMT/PVC
1
12 AWG (Q-Cable)06 AWG BARE
(NOT IN CONDUIT)
2
10 AWG THWN-2
10 AWG THWN-2
(2)10 AWG THWN-2
10 AWG THWN-2
-
-
-A
3/4 in EMT
3/4 in EMT
10 AWG THWN-2
Isc(25°C) = 13.73A, Tisc = 0.054%/°C
Isc(T) = Isc(25°C) x [1 + (0.054/100) x (T-25°C)]
Isc(-2°C) = 13.53A, Isc(31°C) = 13.77A
Voc(25°C) = 41.02V, Tvoc = -0.27%/°C
Voc(T) = Voc(25°C) x [1 + (-0.27/100) x (T-25°C)]
Voc(-2°C) = 44.01V, Voc(31°C) = 40.36V
SYSTEM SUMMARY STC (3.960 kW DC / 2.610 kW AC)
STC DC:(9) 440W = 3.960 kW
STC AC:(9) 290W = 2.610 kW
●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES
● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER
ELECTRICAL NOTES
1)ALL GROUNDING TO COMPLY WITH CEC 690.47.
2)ALL TERMINALS SHALL BE MIN. 75°C RATED.
3)IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A).
4)IQ COMBINER 5/5C REQUIRES ENPHASE HOLD DOWN KIT X-IQ-NA-HD-125A.
DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH
EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216
WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE.
NOTE: SPLICING OF THE WIRE-TYPE GROUNDING ELECTRODE SHALL BE
PERMITTED ONLY BY IRREVERSIBLE COMPRESSION-TYPE CONNECTORS LISTED
AS GROUNDING AND BONDING EQUIPMENT OR BY THE EXOTHERMIC WELDING
METAL WATER PIPING SYSTEM INSTALLED IN OR ATTACHED TO A BUILDING OR
STRUCTURE SHALL BE BONDED PER NEC TABLE 250.66 AND 250.104(A)(1).
•NEW ELECTRICAL SHALL BE LOCATED AT LEAST THREE (3) FEET FROM
GAS METER OR GAS SHUT- OFF VALVES. UPC1208.7.1; NEC 110.26.”
•GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED PER NEC 250.66.● 1X BRANCH OF 9 CONNECTED IN PARALLEL
INTERCONNECTION
120% RULE - CEC 705.12(B)(3)(2)
UTILITY FEED + SOLAR BACKFEED
200A + 20A = 220A
BUSS RATING x 120%
200A x 120% = 240A
(2)
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-5
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
EAST WALL FACING ELEVATION
EQUIPMENT ELEVATION
EQUIPMENT
ELEVATION
SCALE: NTS
NEW ELECTRICAL GUTTERNEW ELECTRICAL GUTTER
(E) METER MAIN COMBO
(N) AC DISCONNECT
FROM
ROOF
TOP
ENPHASE
(N) IQ COMBINER 5/5C
(E) SUB SERVICE PANEL
ON MAIN HOUSE ON ADU
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-6
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
WIRING
CALCULATION
WIRING CALCULATIONS
SCALE: NTS
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL APTOS SOLAR DNA-120-MF10-440W
(440W) SOLAR MODULES
VMP 33.72V
IMP 13.05A
VOC 41.02V
ISC 13.73A
TEMP. COEFF. VOC -0.27%/°C
MODULE DIMENSION 75.1(L) x 44.6(W)
PANEL WATTAGE 440W
Inverter Ratings
Inverter Make/Model
ENPHASE
ENERGY INC.
IQ8PLUS-72-M-US
[240V]
Max DC Volt Rating 60V
Max con output Power 290W
Max Nominal Voltage 240V
Max AC Current 1.21A
Max OCPD Rating 20A
EXTREME CASE MODULE OUTPUT
(APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES)
Isc(25°C) = 13.73A, Tisc = 0.054%/°C
Isc(T) = Isc(25°C) x [1 + (0.054/100) x (T-25°C)]
Isc(-2°C) = 13.53A, Isc(31°C) = 13.77A
Voc(25°C) = 41.02V, Tvoc = -0.27%/°C
Voc(T) = Voc(25°C) x [1 + (-0.27/100) x (T-25°C)]
Voc(-2°C) = 44.01V, Voc(31°C) = 40.36V
● 1X BRANCH OF 9 CONNECTED IN PARALLEL
SYSTEM SUMMARY STC (3.960 kW DC / 2.610 kW AC)
STC DC:(9) 440W = 3.960 kW
STC AC:(9) 290W = 2.610 kW
●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES
● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER
ELECTRICAL NOTES
1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.
2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT.
3) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY
WITH NEC 110.26.
4) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH
ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES
AND STANDARDS.
5) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE
CONTRACTOR SHALL SIZE THEM ACCORDINGLY.
6) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.
7) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT
RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION.
8) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO
GBL-4DBT LAY-IN LUG.
9) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690.
10) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL.
11) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC
310.15(B)(16).
12) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A).
13) IQ COMBINER 5/5C REQUIRES ENPHASE HOLD DOWN KIT X-IQ-NA-HD-125A.
AC wire details
Tag Nominal
Voltage
Expected
max temp
Adjusted ampacity (ampacity x temp
derate x conduit fill derate)
Conductor &
neutral size
A 30 x 1 x 1 = 30.00 A 12 AWG (Q-Cable)
10 AWG THWN-2
#Modules
9
91 240 V
240 V
Backfeed *1.25
/cond.set
13.61 A
Min
OCPD
13.61 A
20 A
20 A
Conductor
sets
1
1
ccConductors
/conduit
-
2
31
Conductor
metal
Cu
Cu
Max
length
30 ft
15 ft
V drop Min EMT/PVC
size
0.47
0.15
EGC size
(Cu)
06 AWG BARE
(NOT IN CONDUIT)
10 AWG THWN-2
-
3/4 in EMT31
10 AWG THWN-22240 V 12.10 A 20 A 1 2 Cu 15 ft10 AWG THWN-2 3/4 in EMT31
35 x 1 x 1= 35.00 A
35 x 1 x 1 = 35.00 A9 0.15
M
JB
ACDCP SSP
WARNING LABELS
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-7
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
& PLACARD
CAUTION:
MULTIPLE SOURCES OF POWER
ELECTRICAL SHOCK HAZARD
WARNING!
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION: INVERTERS, AC DISCONNECTS, AC
COMBINER BOXES
CODE REF: CEC 2022 - 690.13(B)
WARNING
SOLAR SYSTEM CONNECTED AND
ENERGISED
LABEL LOCATION: UTILITY METER
CODE REF: CEC 2022 - 690.13(B)
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
LABEL LOCATION: AC DISCONNECTS FOR
UTILITY ACCESS
CODE REF: CEC 2022 - 690.13(B)
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
LABEL LOCATION: UTILITY SERVICE ENTRANCE (MSP OR
AC DISCONNECT IF LINE SIDE TAP), AND WHEREVER
REQUIRED BY AHJ (INVERTERS, DC DISCONNECTS,
OTHER)
CODE REF: CEC 2022 - 690.56(C)(2)
POWER SOURCE OUTPUT CONNECTION
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LABEL LOCATION: FIRST BACKFEED BREAKER
(MSP/SUBPANEL) IF NO LINE SIDE TAP
CODE REF: CEC 2022 - 705.12(B)(3)(2),
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
10.89 AMPS
240.0 VAC
PV SYSTEM DISCONNECT
LABEL LOCATION: INTERCONNECTION Placard (MSP
BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC
DISCONNECTS
CODE REF: CEC 2022 - 690.54
PHOTOVOLTAIC
AC DISCONNECT
LABEL LOCATION: INTERCONNECTION Placard (MSP
BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC
DISCONNECTS
CODE REF: CEC 2022 - 690.13(B)
WARNING!
TURN OFF PHOTOVOLTAIC AC
DISCONNECT PRIOR TO WORKING
INSIDE PANEL
LABEL LOCATION: MSP
CODE REF: CEC 2022 - 110.27(C)
CAUTION: MULTIPLE
POWER SOURCES
LABEL LOCATION: MSP
CODE REF: CEC 2022 - 690.56(B), CEC 2022 - 705.10
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
NOTICE
PV SYSTEM COMBINER PANEL
DO NOT ADD LOADS TO THIS
PANEL
LABEL LOCATION:
LOAD CENTER
[Only use when applicable for PV load center]
!
Follow all safety procedures and
wear proper PPE in accordance
to NFPA 70E, Failure to comply
can result in serious injury or
death.
Arc Flash and Shock Hazard
Appropriate PPE Required
WARNING
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
LABEL LOCATION: INTERCONNECTION POINT (MSP OR AC
DISCONNECT IF LINE SIDE TAP)
CODE REF: CEC 2022 - 690.56(C)
NOTES AND SPECIFICATIONS
1) SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF CEC 110.21(B), UNLESS
SPECIFIC INSTRUCTIONS ARE REQUIRED BY
SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.
2) SIGNS AND LABELS SHALL ADEQUATELY WARN OF
HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS.
3) LABELS SHALL BE PERMANENTLY
AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN.
4) LABEL SHALL BE OF SUFFICIENT
DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.
5) SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4
- 2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
6) DO NOT COVER EXISTING MANUFACTURER LABELS.
LABEL LOCATION: MSP
CODE REF: CEC 2022 - 705.10, CEC 2022 - 710.10
(E) METER MAIN COMBO
(N) COMBINER PANEL
(N) VISIBLE LOCKABLE
LABELED AC DISCONNECT
(N) SUB SERVICE PANEL
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-10
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
EQUIPMENT
SPECIFICATION
ww
w
.
L
o
y
d
W
M
a
r
t
i
n
.
c
o
m
So
l
a
r
S
t
r
u
c
t
u
r
e
s
E
n
g
i
n
e
e
r
i
n
g
#2
0
2
5
-
0
8
4
5
S
t
r
u
c
t
u
r
a
l
O
n
l
y
Ap
r
i
l
1
,
2
0
2
5
Exp. 3-31-19
No. C58724 NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
2187
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-11
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
EQUIPMENT
SPECIFICATION
ww
w
.
L
o
y
d
W
M
a
r
t
i
n
.
c
o
m
So
l
a
r
S
t
r
u
c
t
u
r
e
s
E
n
g
i
n
e
e
r
i
n
g
#2
0
2
5
-
0
8
4
5
S
t
r
u
c
t
u
r
a
l
O
n
l
y
Ap
r
i
l
1
,
2
0
2
5
Exp. 3-31-19
No. C58724 NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
2187
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
CA
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-12
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
EQUIPMENT
SPECIFICATION
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-8
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
EQUIPMENT
SPECIFICATION
FR
A
N
C
I
S
C
O
G
U
T
I
E
R
R
E
Z
12
1
8
W
C
U
B
B
O
N
S
T
#
2
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
3
,
U
S
A
REVDATEDESCRIPTION
REVISIONS
HOMEOWNER INFO
AP
N
:
0
1
0
2
7
2
0
7
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PV-9
SIGNATURE & SEAL
CONTRACTOR: MY SMART HOUSE
ADDRESS: 39809 AVENIDA ACACIAS, UNIT D
MURRIETA, CA 92563
PHONE: 8884453020
LICENSE #: C-10 1095569
JOSE EMILIO BAHENA
EQUIPMENT
SPECIFICATION
To Whom It May Concern,
This letter serves to confirm I have chosen to have my system installed by My Smart
House for the work being performed at 1218 W Cubbon St, Santa Ana, CA 92703.
Thank you,
Francisco Gutierrez
__________________________
Signature
__________________________
Date
Docusign Envelope ID: F62F7D04-6BC4-42DE-BFAF-3BB0C530C9E0
6/27/2025
Certificate Of Completion
Envelope Id: F62F7D04-6BC4-42DE-BFAF-3BB0C530C9E0 Status: Completed
Subject: Complete with Docusign: HOMEOWNER AUTHORIZATION LETTER.pdf
Source Envelope:
Document Pages: 1 Signatures: 1 Envelope Originator:
Certificate Pages: 4 Initials: 0 My Smart House LLC
AutoNav: Enabled
EnvelopeId Stamping: Enabled
Time Zone: (UTC-08:00) Pacific Time (US & Canada)
39809 Avendia Acacias
Ste D
Murrieta, CA 92563
ops@my-smarthouse.com
IP Address: 47.144.225.4
Record Tracking
Status: Original
6/27/2025 10:58:27 AM
Holder: My Smart House LLC
ops@my-smarthouse.com
Location: DocuSign
Signer Events Signature Timestamp
FRANCISCO GUTIERREZ
frankh9g@yahoo.com
Security Level: Email, Account Authentication
(None)
Signature Adoption: Pre-selected Style
Using IP Address:
2603:8001:3f00:9c7:548e:45cc:56d7:17ab
Signed using mobile
Sent: 6/27/2025 10:59:44 AM
Viewed: 6/27/2025 11:02:31 AM
Signed: 6/27/2025 11:03:14 AM
Electronic Record and Signature Disclosure:
Accepted: 6/27/2025 11:02:31 AM
ID: 4c919260-d4d5-4883-8098-ad04db2ecf53
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 6/27/2025 10:59:44 AM
Certified Delivered Security Checked 6/27/2025 11:02:31 AM
Signing Complete Security Checked 6/27/2025 11:03:14 AM
Completed Security Checked 6/27/2025 11:03:14 AM
Payment Events Status Timestamps
Electronic Record and Signature Disclosure
ELECTRONIC RECORD AND SIGNATURE DISCLOSURE
From time to time, MSH (we, us or Company) may be required by law to provide to you certain
written notices or disclosures. Described below are the terms and conditions for providing to you
such notices and disclosures electronically through the DocuSign system. Please read the
information below carefully and thoroughly, and if you can access this information electronically
to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please
confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and
signatures’ before clicking ‘CONTINUE’ within the DocuSign system.
Getting paper copies
At any time, you may request from us a paper copy of any record provided or made available
electronically to you by us. You will have the ability to download and print documents we send
to you through the DocuSign system during and immediately after the signing session and, if you
elect to create a DocuSign account, you may access the documents for a limited period of time
(usually 30 days) after such documents are first sent to you. After such time, if you wish for us to
send you paper copies of any such documents from our office to you, you will be charged a
$0.00 per-page fee. You may request delivery of such paper copies from us by following the
procedure described below.
Withdrawing your consent
If you decide to receive notices and disclosures from us electronically, you may at any time
change your mind and tell us that thereafter you want to receive required notices and disclosures
only in paper format. How you must inform us of your decision to receive future notices and
disclosure in paper format and withdraw your consent to receive notices and disclosures
electronically is described below.
Consequences of changing your mind
If you elect to receive required notices and disclosures only in paper format, it will slow the
speed at which we can complete certain steps in transactions with you and delivering services to
you because we will need first to send the required notices or disclosures to you in paper format,
and then wait until we receive back from you your acknowledgment of your receipt of such
paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to
receive required notices and consents electronically from us or to sign electronically documents
from us.
All notices and disclosures will be sent to you electronically
Electronic Record and Signature Disclosure created on: 2/6/2020 1:48:36 PM
Parties agreed to: FRANCISCO GUTIERREZ
Unless you tell us otherwise in accordance with the procedures described herein, we will provide
electronically to you through the DocuSign system all required notices, disclosures,
authorizations, acknowledgements, and other documents that are required to be provided or made
available to you during the course of our relationship with you. To reduce the chance of you
inadvertently not receiving any notice or disclosure, we prefer to provide all of the required
notices and disclosures to you by the same method and to the same address that you have given
us. Thus, you can receive all the disclosures and notices electronically or in paper format through
the paper mail delivery system. If you do not agree with this process, please let us know as
described below. Please also see the paragraph immediately above that describes the
consequences of your electing not to receive delivery of the notices and disclosures
electronically from us.
How to contact MSH:
You may contact us to let us know of your changes as to how we may contact you electronically,
to request paper copies of certain information from us, and to withdraw your prior consent to
receive notices and disclosures electronically as follows:
To contact us by email send messages to: britney@my-smarthouse.com
To advise MSH of your new email address
To let us know of a change in your email address where we should send notices and disclosures
electronically to you, you must send an email message to us at britney@my-smarthouse.com and
in the body of such request you must state: your previous email address, your new email
address. We do not require any other information from you to change your email address.
If you created a DocuSign account, you may update it with your new email address through your
account preferences.
To request paper copies from MSH
To request delivery from us of paper copies of the notices and disclosures previously provided
by us to you electronically, you must send us an email to britney@my-smarthouse.com and in
the body of such request you must state your email address, full name, mailing address, and
telephone number. We will bill you for any fees at that time, if any.
To withdraw your consent with MSH
To inform us that you no longer wish to receive future notices and disclosures in electronic
format you may:
i. decline to sign a document from within your signing session, and on the subsequent page,
select the check-box indicating you wish to withdraw your consent, or you may;
ii. send us an email to britney@my-smarthouse.com and in the body of such request you must
state your email, full name, mailing address, and telephone number. We do not need any other
information from you to withdraw consent.. The consequences of your withdrawing consent for
online documents will be that transactions may take a longer time to process..
Required hardware and software
The minimum system requirements for using the DocuSign system may change over time. The
current system requirements are found here: https://support.docusign.com/guides/signer-guide-
signing-system-requirements.
Acknowledging your access and consent to receive and sign documents electronically
To confirm to us that you can access this information electronically, which will be similar to
other electronic notices and disclosures that we will provide to you, please confirm that you have
read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for
your future reference and access; or (ii) that you are able to email this ERSD to an email address
where you will be able to print on paper or save it for your future reference and access. Further,
if you consent to receiving notices and disclosures exclusively in electronic format as described
herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before
clicking ‘CONTINUE’ within the DocuSign system.
By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm
that:
You can access and read this Electronic Record and Signature Disclosure; and
You can print on paper this Electronic Record and Signature Disclosure, or save or send
this Electronic Record and Disclosure to a location where you can print it, for future
reference and access; and
Until or unless you notify MSH as described above, you consent to receive exclusively
through electronic means all notices, disclosures, authorizations, acknowledgements, and
other documents that are required to be provided or made available to you by MSH
during the course of your relationship with MSH.
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
applications@my-smarthouse.com
951-462-5890
Jose Bahena
My Smart House
1095569
1218 W CUBBON ST, SANTA ANA, CA 92703
6/24/2025
Expedited Permit Process for PV Systems - Micro-Inverter1
Expedited Permit Process for PV Systems
Micro-Inverter
The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro-
cess provides a means to differentiate systems that can be permitted quickly and easily
due to their similarity with the majority of small-scale PV systems. Those systems with
unique characteristics may be handled with small additions to this Expedited Permit
Process or may require much more information, depending on the uniqueness of the
installation.
The following pages contain forms for the Micro-Inverter to use with the Expedited Per-
mit Process. The Standard String, AC Module, and Supply-Side Connection forms
are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic-
tions that have adopted the Expedited Permit Process for PV Systems, these forms can
be filled out electronically and submitted in either printed form and via email. An elec-
tronic format is used so that the supplied information is standardized and legible for the
local jurisdiction.
Expedited Permit Process for PV Systems — Micro-Inverter 2
Expedited Permit Process for Small-Scale PV Systems
Micro-Inverter
The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations
are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential
systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been
suggested to provide as a path to permit approval.
Required Information for Permit:
1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it
should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings
with a 3’ perimeter space at ridge and sides may not need separate fire service review.
2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects,
required signs, and ac connection to building (see supplied standard electrical diagram).
3. Specification sheets and installation manuals (if available) for all manufactured components including, but not
limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system.
Step 1: Structural Review of PV Array Mounting System
Is the array to be mounted on a defined, permitted roof structure? l Yes l No
If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1.
Roof Information:
1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________
____________________________________________________________________________________________________
If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…).
2. Does the roof have a single roof covering? l Yes l No
If No, submit completed worksheet for roof structure WKS1.
3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________
Mounting System Information:
1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap
beneath the module frames? l Yes l No
If No, provide details of structural attachment certified by a design professional.
2. For manufactured mounting systems, fill out information on the mounting system below:
a. Mounting System Manufacturer ___________Product Name and Model#________________________________
b. Total Weight of PV Modules and Rails ___________lbs
c. Total Number of Attachment Points____________
d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1)
e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for
maximum spacing allowed based on maximum design wind speed)
f. Total Surface Area of PV Modules (square feet)_________________ ft2
g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2
If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1.
Step 2: Electrical Review of PV System (Calculations for Electrical Diagram)
In order for a PV system to be considered for an expedited permit process, the following must apply:
1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems.
2. The PV array is composed of 4 series strings or less per inverter.
3. The total inverter capacity has a continuous ac power output 13,440 Watts or less
4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)).
5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV
system. Interactive PDF diagrams are available at www.solarabcs.org/permitting.
Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant
understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively
communicate, provide an alternative diagram with appropriate detail.
E
x
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
3
Micro-Inverter Site Plan
E
x
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
4
Micro-Inverter Electrical Diagram
Contractor Name,
Address and Phone:One-Line Standard Electrical Diagram
for Micro-Inverter PV Systems
Site Name:
Site Address:
System AC Size:
SIZE FSCM NO DWG NO REV
E1.1a
SCALE NTS Date: SHEET
Drawn By:
Checked By:
DESCRIPTION OR CONDUCTOR TYPE
USE-2 or PV WIRE
GEC EGC X ALL THAT APPLY
EXTERIOR CABLE LISTED W/ INV.
THWN-2 or XHHW-2 or RHW-2
GEC EGC X ALL THAT APPLY
NO DC GEC IF 690.35 SYSTEM
THWN-2 or XHHW-2 or RHW-2
GEC EGC X ALL THAT APPLY
TAG
1
2
3
4
5
CONDUIT AND CONDUCTOR SCHEDULE
COND.
GAUGE
MFG
MFG
NUMBER OF
CONDUCTORS
MFG Cable
MFG Cable
CONDUIT
TYPE
N/A
N/A
N/A
SAME
SAME
CONDUIT
SIZE
N/A
N/A
N/A
SAME
SAME
DESCRIPTION
PV DC or AC MODULE
DC/AC INVERTER (MICRO)
J-BOX (IF USED)
PV ARRAY
AC COMB. PANEL (IF USED)
GEN METER (IF USED)
AC DISCONNECT (IF USED)
SERVICE PANEL
TAG
1
2
3
4
5
6
7
8
PART NUMBER NOTES
FOR UNUSED MODULES
PUT "N/A” in BLANK ABOVE
1
1
3
2
3
EQUIPMENT SCHEDULE
2
_____
MICRO-INVERTERS
IN BRANCH-
CIRCUIT
MOD
____
DC
AC
MOD
____
DC
AC
MOD
____
DC
AC
MOD
____
DC
AC
MOD
____
DC
AC
MOD
____
DC
AC
J-BOX
4
AC DISCO
M
BUILDING
GROUNDING
ELECTRODE
G
M
UTILITY
SERVICE
MAIN SERVICE PANEL
MAIN
OCPD
INVERTER
OCPD
6
7
8
5
4 5
G
SEE GUIDE APPENDIX D FOR
INFORMATION ON MODULE AND
ARRAY GROUNDING
AC COMBINER
PANEL
G
____
MICRO-INVERTERS
IN BRANCH-
CIRCUIT
E
x
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
5
Contractor Name,
Address and Phone:Notes for One-Line Standard Electrical
Diagram for Single-Phase PV Systems
Site Name:
Site Address:
System AC Size:
SIZE FSCM NO DWG NO REV
E1.2a
SCALE NTS Date: SHEET
Drawn By:
Checked By:
MAX POWER-POINT CURRENT (IMP)
MAX POWER-POINT VOLTAGE (VMP)
OPEN-CIRCUIT VOLTAGE (VOC)
SHORT-CIRCUIT CURRENT (ISC)
MAX SERIES FUSE (OCPD)
MAXIMUM POWER (PMAX)
MAX VOLTAGE (TYP 600VDC)
VOC TEMP COEFF (mV/oC or %/oC )
IF COEFF SUPPLIED, CIRCLE UNITS
MODULE MAKE
MODULE MODEL
PV MODULE RATINGS @ STC (Guide Section 5)
MAX DC VOLT RATING
MAX POWER @ 40oC
NOMINAL AC VOLTAGE
MAX AC CURRENT
MAX OCPD RATING
INVERTER MAKE
INVERTER MODEL
INVERTER RATINGS (Guide Section 4)
1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A
2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A
3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT
4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9)
5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO
NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):
1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC
2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC
2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES),
a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE.
NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E):
OCPD = OVERCURRENT PROTECTION DEVICE
NATIONAL ELECTRICAL CODE®REFERENCES
SHOWN AS (NEC XXX.XX)
NOTES FOR ALL DRAWINGS:
SIGNS–SEE GUIDE SECTION 7
SIGN FOR DC DISCONNECT
SIGN FOR INVERTER OCPD AND AC
DISCONNECT (IF USED)
No sign necessary since 690.51
marking on PV module covers
needed information
AC OUTPUT CURRENT
NOMINAL AC VOLTAGE
SOLAR PV SYSTEM
AC POINT OF CONNECTION
THIS PANEL FED BY MULTIPLE
SOURCES (UTILITY AND SOLAR)
Notes for Micro-Inverter Electrical Diagram
Structural Calculations for a Roof Mounted Solar Photovoltaic System for:
Francisco Gutierrez
1218 W Cubbon St
Santa Ana, CA 92703
Applicable Codes:
2022 California Building Code, 2022 California Electric Code,
2022 California Mechanical Code, American Society of Civil Engineers
Standard ASCE 7-16 Minimum Design Loads for Buildings and Other
Structures, American Wood Council 2018 National Design Specification
for Wood Construction, Local Municipal Code, and all other codes which
are adopted by reference or enacted by law.
Assumed Design Parameters:
The existing structure has been built under a building permit and is in its
original condition. The existing roof structure is capable of its code
required live load and the ability of the roof structure to support live loads
has not been substantially reduced by the age of the structure, termites or
mold, or unauthorized modifications to the existing structure. Solar Energy
Contractor shall make an inspection of the existing roof framing system
prior to installation of the roof mounted solar energy system to verify that
the existing roof is capable of supporting minimum roof live loads.
Assumed Design Parameters:
All 2x members are grade Douglas Fir #2 or better
All 4X members are grade Douglas Fir #1 or better
All Roof Connectors are Simpson Strong-Tie or Equal
All Concrete Foundations are f'c = 2500 psi or stronger
Sht # 1 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Original Structure was built to the Type-V Wood Framed Standards of the
Applicable Building Code at the time of Construction.
Exp. 3-31-19
C L
2187
Note to Building Official:
Based upon a review of the proposed plans I am confident that the
existing roof framing system is capable of safely supporting the additional
loads caused by the new solar photovoltaic energy system. The contractor
shall field verify that the existing roof structure is in its original permited
condition and verify that it can support the normal code required roof live
loads. Attached in this package are several calculations showing that the
roof members can support the additional weight of the solar array.
Furthermore, an analysis of the solar array's support for wind forces and a
seismic analysis of the existing structure are also included.
Check Existing 2X4 Roof Rafters @ 24" O.C.:
(Assume max rafters span = 7.83 ft.)
w =30 psf x 2 ft. = 60 plf
Total load on rafters = 60 plf x 7.83 ft. = 470 lbs
Sht # 2 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
7.83'
Exp. 3-31-19
C L
2187
Check Existing 2X4 Roof Rafters @ 24" O.C.:
Snow Load =0 psf
Dead Load =14 psf
Live Load =16 psf
WDL + LL =30 psf x 2 ft. = 60 plf
WDL =14 psf x 2 ft. = 28 plf
w =30 psf x 2 ft. = 60 plf
Total load on rafters =( 28 plf x 7.83 ft ) + ( 6' x 2.75' x 3 psf x 2 )
+ ( 6' x 1.65' x 3 psf x 1 )
=348 lbs < 470 lbs OK
OK. Per 2022 California Existing Building Code Section 503.3 Alterations
Check attachment of Support to Existing Structure for Wind Uplift
CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING
APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK
ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2.
NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA:
FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS
EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING
CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT
BE LESS THAN ONE-THIRD ITS LENGTH.
EFFECTIVE AREA = 15 SQ FT
Sht # 3 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
% CHANGE =348 lbs - 470 lbs x 100 =-26% < 5% OK470 lbs
Exp. 3-31-19
C L
2187
Check attachment of Support to Existing Structure for Wind Uplift - Cont'd
Tributary Area to Each Solar Mount = 6 ft. x 2.75 ft. = 16.5 sq. ft. ( Max )
Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C):
p = q h (GC p )(γ E )(γ a )Eq'n 29.4-7 ASCE 7-16
q h = 0.00256 K z K zt K d K e V 2 Eq'n 26.10-1 ASCE 7-16
Note:
K z =velocity pressure coefficient Section 29.10.1 ASCE 7-16
K z =0.9 (Exposure C, Height = 20 ft or less)
K zt =Topographical Factor = 1.0
K d =Wind Directionality Factor = 0.85
K e =Ground Elevation Factor = 1.0
V =130 mph
q h =0.00256 (0.9) (1.0) (0.85) (1.0) (130)²
q h =33.1 psf
GC p =-2.0 (Zone 2 ; Effective Area = 15 sq. ft. )
γ E =Exposure Factor = 1.5
γ a =Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4-8 ASCE 7-16
p = q h (GC p )(γ E )(γ a )
p = 33.1 psf (-2.0) (1.5) (0.7) = 69.5 psf
Sht # 4 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Exp. 3-31-19
C L
2187
Check attachment of Support to Existing Structure for Wind Uplift - Cont'd
Nominal (Unfactored) Uplift at each support = 69.5 psf x 16.5 sq. ft. = 1146.75 lbs
Note: Section 2.4.1 of ASCE 7-16, Basic Load Combinations for Allowable Stress
Design. Note: Applicable Load Combination #5 (D + 0.6W)
Design (Factored) Uplift at each support = 0.6 x 1146.75 lbs = 688 lbs
Load per lag screw = 688 lbs / 1 = 688 lbs
Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below
according to the 2018 NDS.
W ' = W x Cd x Ct Table 10.3.1 2018 NDS
where
W = 266 lbs / in. of embedment per Table 12.2a
Cd = 1.6 per Table 2.3.2 of 2018 NDS
Ct = 1.0 per Table 2.3.3 of 2018 NDS
W' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 688 lbs OK
Sht # 5 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Use Support connected to 2x Min. Roof Member w/
(1) 5/16" x 3.5" lag screws per connection minimum.
Exp. 3-31-19
C L
2187
Check Seismic load due to added dead load of photovoltaic system.
Determine Seismic Weight of Existing Building:
Effective Existing Seismic Weight
Area of (E) Building =Approximately 700 Sq. ft
Approximate
Effective =700 sq. ft. x 30 psf ave. = 21,000 LBS
Seismic Weight
DETERMINE BASE SHEAR
V = Cs W EQ'N 12.8-1 ASCE 7-16
EQ'N 12.8-2 ASCE 7-16
R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1
R =6.5 WOOD SHEAR WALLS
Ie = 1.0 IMPORTANCE FACTOR
SDS = 2/3 x SMS
SMS = FA x SS
SMS = 1.2 x 1.5 = 1.8
SDS = 2/3 x 1.8 = 1.2
Cs ==0.185 EQ'N 12.8-2 ASCE 7-16
Sht # 6 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Cs =SDS
R
Ie
SDS
R
Ie
Exp. 3-31-19
C L
2187
EXISTING BASE SHEAR
V = 0.185 x 21,000 LBS = 3,885 LBS
DETERMINE NEW BASE SHEAR
Determine Seismic Weight of Building with Solar Array:
EXISTING
SEISMIC =21,000 LBS
WEIGHT
NEW SOLAR
ARRAY =3 PSF x 9 PANELS x 5.5' x 3.3' = 491 LBS
NEW
SEISMIC =21,000 LBS + 491 LBS = 21,491 LBS
WEIGHT
THEREFORE NEW BASE SHEAR:
V = 0.185 x 21,491 = 3,976 LBS EQ'N 12.8-1 ASCE 7-16
OK. PER ASCE 7-16 SECTION 11B.4 ALTERATIONS
EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT
FROM ANALYSIS SINCE NEW SEISMIC FORCE IS
LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE
Sht # 7 of 7
2025-0845 Smart House Francisco Gutierrez April 1, 2025
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
"Alterations may be made to any structure without requiring the existing structure to comply
with this standard, provided that the alterations comply with the requirements for a new
structure. Alterations that increase the seismic force in any existing structural element by
more than 10% or decrease the design strength of any existing structural element to resist
seismic forces by more than 10% shall not be permitted unless the entire seismic force-
resisting system is determined to comply with this standard for a new structure."
End of Calculations
Email: loydwmartin@gmail.com www.loydwmartin.com
% CHANGE =3,976 LBS - 3,885 LBS x 100 = 2.3 % < 10 % OK3,885 LBS
Exp. 3-31-19
C L
2187