HomeMy WebLinkAbout2600 S Bristol St - REV 1 - PlanGENERAL NOTES
A.SEE INTERIOR FINISH SCHEDULE FOR ALL CEILING FINISHES.
B.DO NOT SCREW THE CEILING GRID TO THE STAINLESS STEEL HOODS. REFER TO
DETAIL 2/A1.2.
C.REFER TO ELECTRICAL AND/OR HVAC DRAWINGS FOR ADDITIONAL INFORMATION
REGARDING ALL FIXTURES, DEVICES AND EQUIPMENT SHOWN ON THIS PLAN.
D.VERIFY CONFIGURATION OF MUSIC SYSTEM IN DINING ROOM. COORDINATE
REQUIREMENTS WITH WENDY'S I.T. CONTACT.
E.VERIFY CONFIGURATION OF WIFI SYSTEM. COORDINATE REQUIREMENTS WITH
WENDY'S I.T. CONTACT.
F.ALL LIGHT FIXTURES MOUNTED IN CEILING TILES ARE TO BE CENTERED IN THE
TILE U.N.O.
G.USE ALTERNATE MATERIAL BELOW ROOFING DECK INSTEAD OF TECTUM
#CODED NOTES:
1.EXPOSED STRUCTURAL OPEN WEB TRUSSES PAINT P12. INSTALL 1/2 " ZINTRA SLATE
PANELING ZTR4706 ACOUSTICAL PANELS OVER EXITING DECK..
2.TRACK LIGHTS. TRACK TO BE MOUNTED AT 12'-0" AF.F. REFER TO ELECTRICAL
DRAWINGS FOR FIXTURE INFORMATION.
3.LIGHT FIXTURES IN PICK UP WINDOW CANOPY. REFER TO ELECTRICAL DRAWINGS.
4.SPEAKER. PROVIDE BLOCKING AS REQUIRED.
5.EXHAUST HOODS. REFER TO MECHANICAL DRAWINGS.
6.G.C. TO PROVIDE AND INSTALL LIGHTING FOR COOLER/FREEZER/RECEIVING UNITS W/
MOTION SENSOR.
7.REFER TO EXTERIOR ELEVATIONS FOR MOUNTING LOCATIONS OF WALL MOUNTED
LIGHT FIXTURES (TYP.).
8.CONT. 2" VENT SCREED.
9.PAINT WALLS ABOVE 11'-6" (ABOVE TRIM), EXPOSED STRUCTURE, CONDUITS, J-BOXES,
WIRING, PIPING, DUCTS AND REGISTERS , W/ PAINT INDICATED ON FINISH PLAN.
10.PENDANT LIGHTING, BOTTOM OF FIXTURE TO BE ALIGNED WITH B.O. TRUSSES.
REFER TO ELECTRICAL DRAWINGS.
11.EQUIPMENT CHASE. REFER TO ELECTRICAL AND MECHANICAL DRAWINGS.
12.EXTEND GYP. BD. TIGHT TO DECK ABOVE.
13.FREEZER/COOLER EVAPORATOR, REFER TO MECHANICAL DRAWINGS.
14.PATIO HEATERS. REFER TO ELECTRICAL DRAWINGS. PATIO HEATER, LOCATIONS TO
BE FIELD COORDINATED TO MEET MANUFACTURER'S CLEARANCE REQUIREMENTS TO
COMBUSTIBLES.
15.JOIST BRIDGING, REFER TO STRUCTURAL DRAWINGS.
16.BOX CHANDELIER TO BE MOUNTED AT 6'-8" A.F.F. & CENTERED OVER TABLE BELOW.
PROVIDE BLOCKING AS REQUIRED. REFER TO ELECTRICAL DRAWINGS.
17.MONO POINT SPOT LIGHT FIXTURE TO BE MOUNTED AT BOTTOM OF JOIST &
CENTERED ON TABLES BELOW. PROVIDE BLOCKING AS REQUIRED. REFER TO
ELECTRICAL DRAWINGS
18.PENDANT GLOBE LIGHT TO BE MOUNTED AT 6'-0" A.F.F. CENTERED OVER TABLE
U.N.O. REFER TO ELECTRICAL DRAWINGS AND INTERIOR ELEVATIONS
19.LED STRIP LIGHT AT CORNICE/PARAPET CAP. REFER TO ELECTRICAL DRAWINGS.
20.MAIN DUCT TO BE 2" BELOW BOTTOM OF JOIST
21.SPEAKER.
22.PATIO STRING LIGHTS, REFER TO ELECTRICAL.
23.SURFACE MOUNTED PATIO CEILING LIGHT, REFER TO ELECTRICAL.
24.SURFACE MOUNTED PATIO BLADE LIGHT, REFER TO ELECTRICAL.
25.ALL EXPOSED STRUCTURE, CONDUITS, J-BOXES, AND WIRING, TO BE PAINTED
PEX-12. REFER TO FINISH PLAN.
26.STAINLESS STEEL CHASE TIED INTO UNDERSIDE OF SOFFIT FOR DRINK LINES BY KED.
27.DRAFT STOP AT 20'-0" MAX. INTERVALS HORIZONTALLY. AT BRACING TYP.
28.METAL CANOPY/AWNING. HEAT TRACE, SUPPLY AND INSTALLED BY G.C., REFER TO
EXTERIOR ELEVATIONS AND WALL SECTIONS
STRING LIGHT
CELING MOUNTED
HEATER
LED LIGHT
FIXTURE
EMERGENCY
EGRESS LIGHT
WIB LIGHT
LEGEND
SUSPENDED
LIGHT FIXTURE
DIRECTIONAL
TRACK LIGHT
AIR DIFFUSERS
SW SUB WOOFER
SPEAKER
DIRECTIONAL LIGHT
RECESSED CAN LIGHT
EXIT LIGHT
SP SP
LED TAPE LIGHT
EMERGENCY LIGHT NOTE:
THE POWER SUPPLY FOR MEANS OF
EGRESS ILLUMINATION SHALL
NORMALLY BE PROVIDED BY THE
PREMISES ELECTRICAL SUPPLY. IN THE
EVENT OF POWER SUPPLY FAILURE,
THE EMERGENCY POWER SYSTEM
SHALL PROVIDE POWER FOR A
DURATION OF NOT LESS THAN 90
MINUTES AND SHALL CONSIST OF
STORAGE BATTERIES, UNIT EQUIPMENT
OR AN ON-SITE GENERATOR. BUILDING
CODE 1006.3
SP SP
SP
SP
SPSP
CEILING GRID AND ACT (CT-1)
CEILING GRID AND WASHABLE ACT
(CT-4)
CEILING GRID AND ACT (CT-2)
CEILING GRID AND WASHABLE,
NON-COMBUSTIBLE CLG. TILE (CT-5)
FIRE DEPT. NOTES
1.THE MEANS OF EGRESS, AND EXIT DISCHARGE,
SHALL BE ILLUMINATED AT ANY TIME THE
BUILDING IS OCCUPIED WITH A LIGHT INTENSITY
OF NOT LESS THAN 1 FOOT-CANDLE AT THE
WALKING SURFACE LEVEL. BUILDING CODE
1006.2.
2.EGRESS DOORS SHALL BE READILY OPENABLE
FROM THE EGRESS SIDE WITHOUT THE USE OF A
KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
BUILDING CODE 1008.1.9.
3.EXITS, EXIT ACCESS DOORS AND PATHS OF
EGRESS TRAVEL THAT IS NOT IMMEDIATELY
VISIBLE TO THE OCCUPANTS SHALL BE MARKED
BY AN APPROVED EXIT SIGN THAT IS READILY
VISIBLE FROM ANY DIRECTION OF EGRESS
TRAVEL. EXIT SIGNS SHALL BE INTERNALLY OR
EXTERNALLY ILLUMINATED. BUILDING CODE 1011.
5'-0"5'-0"5'-0"5'-0"5'-0"
DINING
101
42 SEATS
EQ
.
EQ
.
01 REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
5
A4.5
4
A4.5
3
A4.5
2
A4.5
1
A4.5
6
A4.5
19
19
77
19 9
3
5
27
6 6
7 7 19
5
27
27
16
18
4
19
2
4
4
4
19
19
19
CT-1
9'-0"
CT-4
9'-6"
WT-8
9'-4"
5
A4.5
4
A4.5
3
A4.5
2
A4.5
1
A4.5
6
A4.5
CT-4
10'-0"
CT-5
8'-0"
CT-1
8'-0"
2
AC
1
AC
1
1
1
SD-4
100
SD-4
100
6"Ø
6"
Ø
8"Ø
RETURN PLENUM
SD-5
311
SD-5
311
SD-5
311
SD-5
311
SD-5
311
5
14
"
X
1
4
"
4RTU-1
S
16
"
X
2
0
"
RG-1
-900
RG-1
-900
RTU-1
SD-5
311
SD-5
311
SD-5
311
SD-5
311
9"Ø
9"Ø
9"Ø
9"Ø
9"Ø
9"Ø
9"Ø9"Ø
9"Ø
12
TYP
28
2
DO NOT FASTEN TO HOODS
CEILING TILE.
REFER TO
REFLECTED
CEILING PLAN
HOOD
8 GA. HANGER WIRE AT
4'-0" O.C. G.C. TO
SUSPEND TRACK FROM
STRUCTURE ABOVE
2
CEILING DETAIL @ HOOD
3" = 1'-0"
B.O. SOFFIT
7'-1" AFF
2X4'S @ 16" O.C.
2x8 BLOCKING @ 16"
O.C. CONNECT TO EA.
TRUSS W/ SIMPSON A35
(N) CONT. 2X6 ONE BAY
BEYOND
FRP OVER 5
8" TYPE "X"
GYP. BD.
BLOCKING
(4) - 16d MIN.
2X4 LEDGER W/
(3) 16d MIN. EACH STUD
3SOFFIT - ELEC. PANELS
3/4" = 1'-0"
CONNECTED BY
SIMPSON TIE
SIMPSON TIE
CONT. 18 GA
TRACK CONNECT TO
STRUCTURE ABOVE
5/8" GYP. BD.6" STEEL STUD FRAMING
@16" O.C.
T-GRID CEILING
STEEL STUD BRACING @
48" O.C. TO STRUCTURE
OR BLOCKING ABOVE,
CONNECT W/ #8 SCREWS,
ALTERNATING DIRECTION
SS CAP
5SOFFIT DETAIL
1-1/2" = 1'-0"
4HANGING DETAIL
3/4" = 1'-0"
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: **/**/****
PROJECT NUMBER: *****
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
26
0
0
S
B
R
I
S
T
O
L
S
T
SA
N
T
A
A
N
A
,
C
A
PROJECT TYPE:
00000
GLOBAL NEXT GEN 30
FREESTANDING
NEW
COMPANY/FRANCHISE
2022
NEW BUILD
XXXX
GLOBAL
SPRING 2023
NEW
GLOBAL NEXT GEN 30
REN. 5/31/25
ARMET DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
REFLECTED CEILING PLAN
A1.2
OWNER REV.04/18/255
HEALTH DEPT CORR.02/27/254
BLDG DEP CORR.02/27/253
Revision to 101122144, 20184845, &
40139890 (issued on 5/22/25)
Rev 1 - Bldg #101123998
Elect #20186036
Mech #40140439
APPROVALS:
PLNG - C. Santana
BLDG/ELECT/MECH - CSG
CITY OF SANTA ANA
H2.5A 932" - LINE OF TOWER ling and BuHdin. Xgnncy
TO BE REDUCED
(CONY.) PLY I ) B.N. I 3
(TYP") (VERIFY W/ ARCH'L) (N) 4x10 LEDGER H2"5A 632"
W/ 4-1/4"x�o1/2" SDS VERIFY (E) SHEAR B" "
(N) E.N. SCREW Q S" O.C. TRANSFER OR ADD (CONT.) PL B.N. 2x PTDF W/ YO 2-04 DO ELS A O e
(N) E. (CONT.) PLY (N) A35 2�" O.C. AB 6 48" (2-MIN (4-TOTA ) DRILL
(N) B.N" (N K, �� 2411G (N) 2x BLK'G W/ E"N"J • ° 3❑ ITYPJ PER SILL) �� EP Y� PER T U A N
VERIFY BL LEDGER MIN. � � � W/SIMPS N 'SET
REPLACE (E) BRACE IN led a S O.C. s i i�
(E) PLY E.N. u I
3-6d KIND G (N) TOWER HEIGHT E"N" E.N. XP [CC- SR 2508 - I_.,
l�3 MIN.) BRACE IN" (IF OCCURS) (N) A35 a 2�" (N) 2x6 BRACE T4B e
W/ �10X3/4" SCREW 4 Is 60" O"C"(V) 3L3 MIN. 3 MIN. z ARMET DAVIS NEWLOVE &
(E) BRACE TO BOTT. OF (E) EA. STUD E"N" -�AIA ARCHITECTS
ATTACHMENT TO REMAIN ROOF PLY W/ 3-10d EA" END MSTA36(N) 16" O"C" E N _ — — —_ S WPCIATES,
_�—I I, - 1330 OLYMPIC BLVD.
(E) BLK'G OR REVISED Or, TO NOTCH PLY _ z
� a t e . SANTA MONICA, CALIFORNIA 90404
(N) 2x(o(N) MSTA3(o(V) a 111 2-04 ��- XIST PH310452-5533 FAx310450-4742
L REF" 20 ❑3 BRACE T45 OOTING
MIN" Q T45 (E) BRACE .
5'-0" TO REMAIN
lN) AWNIN lEl) BMI — O.C.(V) (WHERE OCCURS)
(E) TRUSS lE) (E) TRUSS OR °
BY OTHERS I I (E) lN) BM (E) FRAMING (CUT
(WHERE LEDGER TRUSS TRUSS PER PLAN BACK AS REQ'D FRAMING (DIRECTION EA" STUD
SION PER ARCH'L
OCCURS) STOREFRONT TO REMAIN TO FIT W/ (N) HGR E.N. QHDR MAY VARY)
W/ 3-10d m REQUIIRED FOR NEW WALLS
EA" END E.N.
PtR 4RCH'L�II (E) (N) BM PER PLAN
(1tH OCCURS) II PLY (WHERE OCCURS) L
.1.L u
() YL(E)�-
E P (E)
15 (N) RT • • FRAMING BM (E) WALL
REF. _ CURB ° ° (E) (E)
3-1i¢"0 x 31/2" SDS 15 (E) PLY
SCREW � PLY REF" _ CURB U (WHERE OCCURS) E.N.H FASTENER TRUSS
EQ. SPACED J TO REMAIN 2x PTDF W/ YO
(TYP.) 3-1/4110 x 31/2" SDS (N) POST 3 AB 6 48" (2-MIN
N) RTU CURB SCREW e PLY PER PLAN (N) 6x10 II CONC. lE) BM PER SILL)
(LOCATE II WALL (WHERE
EQ. SPACED PER II I (WHERE OCCURS) 2-04 DOWELS (4-TOTAL)
(TYP") ARCH'L) II I OCCURS) d E"N. DRILL 4" 4 EPDXY
(N) A34 EA. W/SIMPSON 'SET' XP
SIDE OF POST (E) SLAB ICC-ESR 2508
z
_ N) 4x6 P R AN (N) 4x (N) /� ULL
(N) 3/�" FULL DEPT 3 cA
PLY x 12" WIDE N) LUS�6 PAC NGR PER PL
DEPTH Y
MIN. (NAIL TO PLY) x 12" WID
X 31/2u SDS 3_1/4"� x 31/Zu S #
T BZ - EXIST FOOTING
SCREW PLY SCREW 6 PL �\
EQ. SPACED (E) FOOTING
ITYP") 12" MIN" (TYP.)
E) TRUSS � 6
PER PLAN - _ DIMENSION PER ARCH'L AS
�/] o REQUIRED FOR NEW WALL O
(E) PLY
,L*" .SECURE PER
MANUF" SPECS.
E.N. (N) FULL DEPTH BLKG �x SLEEPERS 3 1
TO MATCH � (E) PLY PERIMETER OF (/s � x 3 /2 LAG EA. �
CORNER MIN") HTK
(E) (REPLACE 6 STUD EDGE (WHERE OCCURS) (N) POST PLATFORM
STRUCTURAL ENGINEERS, LLP
IN KIND) PER PLAN 0 14288 Danielson Street • Suite #200 • Poway, CA 92064-8819
n, ROOF SHEATHIN
• • (N) A3� EA" (858) 679-8989 WWW. HTKSE.COM Fax (858) 679-8959
SIDE OF POST S IMPSON 43E> (1) -S -IN�7
(�
EDGE OF (N) 2x STUD (E) SLAB —ALIGN a (E) JOIST ORTO MATCH (E) 24" TRUSS LOC" OR (N) 4x BLKG 6 CURB�oFEs
2�" O/C -(MIN. 2 EA. SIDE)ALIGNED (E) TRUSS OR
OPTION: DAMAGED 2x STUDS TO — PROVIDE (N) 4xr 6 49
-1 PERIMETER OF
. MECH.
BLK'G 6 RTU 6/30/26
BE 1REPLACED IN KIND OR PLACED . . 11=I Ii=i �I PERIMETER s'qT civ\�
ADJACENT W/ A34 TOP 4 BOTT. 2-ROWS OF 11 a 11/2" „III= PLATFORM SECURE W/ F o
.. (2- OF 18 #1OX3/�. C��4LV" SCREl�1S (LADDER FRAME � 24" of CP�-�F
ROWS O"C. 6 PARALLEL
NOTE: PROVIDE SNORING AT
3(o TOTAL NAILS) CONDITION)
TOP PLATES IF MORE THAN 0 0 1. CONTRACTOR TO VERIF`I'
2 BAYS ARE REPAIRED. m OPTION: ALIGN (N) FULL HT. 2x STUD ADJACENT (E) FOOTING
W/ A34 TOP 4 BUTT. PENETRATIONS W/
NOTE: EXISTING ANCHOR BOLTS ROOFln1ARRANTI'
CAN BE REUSED ON NEW SILLS
IF CORROSION OR DAMAGE IS EDGE OF (E) DAMAGED
NOT PRESENT STUDS
(N) FULL DEPTH BLK'G 2 - CTS216 STRAP FRAMING NOT
(N) PLYWOOD e STUD EDGE (1 EA. SIDE OF T.
i�PLACED IN KIND SHOWN
(PLY 4 NAILING TO PL. BRRV TYP.
(E) FRAMING JST
MATCH (E)) VERIFY (E) SILL TO RREUSE OR (N) 2x PTDF SILL DIR MAY VARY
W/ 5/$" 0 TITEN HD OR 5/8" A+LLTHREAD TO MATCH (E) A"B. _ _ Idam
SPACING (48" O.C. MAX)
DRILL 4 EPDXY FOR ALL THREAD WENBRIS T— 2600 S
EX W/ 511- JAI SET-3G ICC ESR 4051 SANTAANA, CA
TO MATCH (NOTE: EXISTING ANCHOR BOLTS CAN BE REUSED IF
(E) (REPLACE DAMAGE IS NOT P1�SENT) B oT14EF6 xoPT DME 10�4-2024
IN KIND)
— CUT PL'S �
3" MIN. PLUMBING (TYP.) im N• 24-34M
DRAWN BY DIM BY
FIE NW(N) IIBLK'G W/ A35 TOP 4 BOTT"
EA ENE) @(N) AWNING/CANOPY
ATTACHMENTS POINTS
TYP" 6 ALL CANOPY LOCATIONS
TYPICAL DAMAGED STUD REPAIR TYPICAL CUT TOP PLATE REPAIR
0 S101
o
AND LAP i� ga(CUT �
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
SP SP
SP
SP
SPSP
ELECTRICAL GENERAL NOTES
LIGHTING GENERAL NOTES
A. CONNECT EXIT/EMERGENCY/NIGHT FIXTURES TO UNSWITCHED HOT CONDUCTOR AHEAD OF
ANY LIGHTING CONTROLS.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND DETAILS FOR THE LOCATION OF
ALL LIGHTING FIXTURES AND ALL OTHER CEILING MOUNTED EQUIPMENT. VERIFY MOUNTING
HEIGHTS AND FINISHES WITH ARCHITECT PRIOR TO ROUGH-IN.
C. REFER TO THE POWER PLANS FOR LOCATION OF ELECTRICAL EQUIPMENT.
D. PROVIDE INDICATED CONDUCTOR SIZE FOR ENTIRE CIRCUIT WHERE CONDUCTOR SIZES
ARE SHOWN ON HOMERUNS.
E. PROVIDE A DEDICATED NEUTRAL WITH ALL DIMMING SYSTEM CIRCUITS. NO COMMON
NEUTRALS SHALL BE ALLOWED.
F. PROVIDE (2) ADDITIONAL #12 CONDUCTORS FOR ALL 0-10V DIMMING CIRCUITS.
1. JUNCTION BOX ABOVE CEILING FOR HOOD LIGHTS AND EXHAUST HOOD.
2. PROVIDE WEATHERPROOF JUNCTION BOX AND TOGGLE TYPE 20A-1P DISCONNECT FOR
SIGNAGE. COORDINATE EXACT REQUIREMENTS WITH SIGN CONTRACTOR. VERIFY
LOCATION PRIOR TO ROUGH IN.
3. PROVIDE LAMP FOR HOOD LIGHT. SUBSTITUTION OF CFL OR INCANDESCENT LAMP IS
PROHIBITED.
4. LOCATION OF LIGHTING SWITCH BANK. REFER TO SWITCH AND HOOD SUPPRESSION
ELEVATION ON SHEET E5.1 FOR ADDITIONAL INFORMATION.
5. PROVIDE RECEPTACLE FOR DINING ROOM SIGNAGE. REFER TO ARCHITECTURAL
ELEVATIONS FOR EXACT MOUNTING LOCATION
6. LED TAPE LIGHTING DRIVER MUST BE INSTALLED INSIDE OF BUILDING DUE TO
TEMPERATURE RATING OF DRIVER. REFER TO LED DRIVER MOUNTING DETAIL, SHEET E5.2
7. LIGHTS IN CANOPY PROVIDED BY CANOPY MANUFACTURER.
8. EXTERIOR LED TAPE LIGHTING 'TL1'. REFER TO ARCHITECTURAL SHEETS FOR MORE
INFORMATION. VERIFY LENGTHS AND DRIVER REQUIREMENTS PRIOR TO INSTALLATION.
REFER TO WALL PENETRATION DETAIL, SHEET E5.2.
CODED NOTES:
A. COORDINATE WORK WITH MECHANICAL, REFRIGERATION AND EQUIPMENT CONTRACTORS,
INCLUDING COOLER/FREEZER WORK AND ICE MACHINE CONDENSING UNITS.
B. VERIFY ROUGH-IN DIMENSIONS AND POWER REQUIREMENTS WITH KITCHEN EQUIPMENT
DISTRIBUTOR PRIOR TO ROUGH-IN.
C. PROVIDE FINAL CONNECTIONS WITHIN FRONT COUNTER, COOKCENTER PANEL, REMOTE
REFRIGERATION UNITS, AND ICE MACHINE REMOTE UNIT WHEN INSTALLED BY VENDOR.
D. VERIFY AVAILABLE FAULT CURRENT AT PRIMARY SERVICE AND COMPATIBILITY WITH
MODULAR PANEL SYSTEM.
E. ENSURE ADEQUATE CONDUIT SIZE FOR ELECTRICAL AND COMMUNICATION WIRING ON SITE
AND INTO BUILDING.
F. CIRCUITS MAY BE GROUPED WITHIN COMMON CONDUITS PER NEC REQUIREMENTS UNLESS
NOTED OTHERWISE.
G. PROVIDE WALL BOX WITH 1/2" CONDUIT WITH PULLSTRING AND NYLON BUSHING STUBBED
ABOVE NEAREST ACCESSIBLE CEILING FOR THERMOSTATS, TEMPERATURE SENSORS,
CARBON DIOXIDE SENSOR, AND HUMIDISTATS UNLESS OTHERWISE NOTED.
H. WIRE ROOF TOP UNIT CONTROL CIRCUIT THROUGH AUXILIARY CONTACTS IN SMOKE
DETECTOR AND MAKE ALL FINAL CONNECTIONS. (TYPICAL OF ALL ROOF TOP UNITS)
I. COOKCENTER IS ASSEMBLED AND PREWIRED AT THE FACTORY. WIRING IS PROVIDED IN THE
PRE- INSTALLED SPLICE BOX, COILED AND TAGGED. A LENGTH OF CONDUIT WITH WIRES IS
PROVIDED FOR THE REMOTE CONDENSING ROOFTOP UNIT. RUN POWER FROM THE SPLICE
BOX TO THE COOKCENTER PANEL.
J. ROOFTOP UNIT IS FACTORY PROVIDED WITH DISCONNECT AND UNPOWERED SERVICE
RECEPTACLE.
K. IN AREAS WITHOUT CEILINGS OR WHERE ANY CONDUITS, CONDUCTORS, FEEDERS, OR LOW-
VOLTAGE WALL EMT CONDUIT CABLING IS VISIBLE, ALL WIRING SHALL BE IN RIGID
GALVANIZED STEEL (RGSC) OR THIN WALL EMT CONDUIT. BX, AC, AND MC CABLE ARE NOT
PERMITTED. CONDUITS ARE TO BE RUN TIGHT TO DECK EITHER PARALLEL OR
PERPENDICULAR TO BUILDING LINES AND ONLY DROP AT POINT OF CONNECTION. JUNCTION
BOXES SHALL HAVE CIRCUIT NUMBERS WRITTEN ON THE INSIDE OF THE JUNCTION BOX
COVER.
L. SEAL ROOF PENETRATIONS PER ROOFING MANUFACTURER'S INSTRUCTIONS.
M. COORDINATE WORK ABOVE THE CEILING WITH OTHER TRADES TO PROVIDE THE GREATEST
POSSIBLE CLEARANCE.CONDUITS SHALL BE ROUTED IN THE DIRECTION OF THE TRUSSES.
N. ONLY EMT CONDUITS ARE ALLOWED IN RECEIVING/DRY STORAGE.
O. DEFINITIONS:FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR
INSTALLATION.INSTALL MEANS TO PLAN IN POSITION AND MAKE CONNECTIONS FOR SERVICE
OR USE.PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED
USE.
A-2
B1
RECESSED CAN LIGHT FIXTURE
RECESSED CAN NIGHT LIGHT FIXTURE
LED LIGHT FIXTURE
LED NIGHT LIGHT FIXTURE
CEILING MOUNTED CYLINDER
MONO POINT LIGHT FIXTURE
EMERGENCY REMOTE EGRESS HEAD
CIRCUIT NUMBER
FIXTURE SYMBOL
OCCUPANCY SENSOR (WALL MOUNTED OR
CEILING MOUNTED)
SINGLE POLE WALL SWITCH AT 4'-6" A.F.F.
EMERGENCY FLOOD LIGHT (WALL MOUNTED OR
CEILING SURFACE MOUNTED)
DIMMER SWITCH, (LEVITON #IP710-DLZ-WH)
LIGHTING LEGEND
LED TAPE LIGHT
GLOBE PENDANT LIGHT
PENDANT LIGHT
TRACK HEAD
BUILDING MOUNTED DECORATIVE LIGHT
LIGHTING TRACK
LIGHT FIXTURE SCHEDULE
CONTACT WENDY'S APPROVED LIGHTING SUPPLIER
UPDATED: 8.26.2022
FIXTURE DESCRIPTION MANUFACTURER FIXTURE NUMBER FIXTURE
WATTAGE VOLTAGE
A1 LED - RECESSED DOWNLIGHT, T-GRID MOUNTED. 3000K.
DIRECT CONNECT LED. WHITE
BOLT BEBRK-LED56-BW-3-ECO 12 120
B4 2x4 LED FLAT PANEL LED. 4000K. WHITE
BACK OF HOUSE ONLY
BOLT BELEDPNL2X4-40W-4K 50 120
EM2B EMERGENCY LIGHT. BLACK. HIGH LUMEN OUTPUT
BOLT BELEDR-1B-HL 1.8 120
BEST LIGHTING LEDR-1B-HL 1.8 120
EMERGENSEE SEELEDR-1B-HL 1.8 120
EM2W EMERGENCY LIGHT. WHITE. HIGH LUMEN OUTPUT
BOLT BELEDR-1W-HL 1.8 120
BEST LIGHTING LEDR-1W-HL 1.8 120
EMERGENSEE SEELEDR-1W-HL 1.8 120
EX1B
EXIT/EMERGENCY LIGHT COMBO, HIGH LUMEN, BLACK, RED
LETTERS. REMOTE CAPACITY. FRONT OF HOUSE ONLY.
BOLT BELEDCXTEU2RBRCHL 3.7 120
BEST LIGHTING LEDCXTEU2RBRCHL 3.7 120
EX1W EXIT/EMERGENCY LIGHT COMBO, HIGH LUMEN, WHITE, RED
LETTERS. REMOTE CAPACITY
BOLT BELEDCXTEU2RWRCHL 3.7 120
BEST LIGHTING LEDCXTEU2RWRCHL 3.7 120
EMERGI-LITE ELXN400-R-2LEDR 3.6 120
EX1RB
EXTERIOR EMERGENCY LIGHT. BLACK. TWIN LAMP.
WEATHER PROOF.
BOLT BERHLED2-PWP-MVB 4 120
BEST LIGHTING RHLED2-PWP-MVB 4 120
OS2 WALK IN COOLER / FREEZER MOTION SENSOR KASON 1901A-5
BUILDING LIGHTING - EXTERIOR
WP4 EXTERIOR SECURITY LIGHT, INTEGRAL LED WITH PHOTOCELL
5000K
RAB WPLED26N/PC 26 120
ABB WL-26501PC 26 120
A6 LED - DOWNLIGHT - EXTERIOR . 3000K. DIRECT CONNECT.
NICKEL NICOR DLR56-3012-120-3K-NK 19 120
36 120
WITH MINIMUM 90 MIN BATTERY BACKUP
WITH MINIMUM 90 MIN BATTERY BACKUP
WITH MINIMUM 90 MIN BATTERY BACKUP
WITH MINIMUM 90 MIN BATTERY BACKUP
WITH MINIMUM 90 MIN BATTERY BACKUP
EL-1 LINEAR LED LIGHT BAR- 3" X 48"VICEROY WENS-VCYW48-FLO-L36.0-ZE-UNIV 120
T2 THEATRICAL VERTICAL LED TRACK HEAD, TRACK MOUNT,
ART PACK LIGHTS, BLACK, 3500K, THEATRICAL SHADES. 18"
EXTENSION ROD
CONTECH LIGHTING CTL8061VS35D-B-BD16A
18" EXTENSION 10 120
T2T TRACK SYSTEM 2', 4', 6' LENGTH CONTECH LIGHTING LT-2B, LT-4B, LT-6B
WB1 WALK-IN COOLER/ FREEZER LIGHT. INTEGRAL LED, NSF
RATED, 4000K, WHITE
MAXLITE LSV4U23WCSCR 34.2 120
TL1 EXTERIOR LED TAPE LIGHTING SYSTEM. 3500K CONTECH LIGHTING TLT24V35K PACKAGE. CONTACT WENDY'S LIGHTING SUPPLIER
P5 UM BRIGHT GLOBE PENDANT. INTEGRAL LED 3500K ARKANSAS LIGHTING 4240P-LED 20 120
P1 FMLWL-LNK-48-ALO4-8SWW2
LED DRIVER
4000K, 2000 LUMEN 25 120LITHONIA LIGHTING
RT ELA QM T WP 3 120HOLOPHANE LIGHTING
MAXLITE RR6119CSW 11 120
B2 2x2 LED FLAT PANEL LED. 4000K. WHITE
BACK OF HOUSE ONLY
BOLT BELEDPNL2X2-40W-4K 40 120
MAXLITE MLFP22G418WCSCR 30 120
BARRON LPA22-30-4K 30 120
A7 LED - 5" CYLINDER LIGHT, 3000K, INTEGRAL LED, BLACK PROGRESS P5774-31/30K 17 120
01 LIGHTING PLAN
SCALE: 1/4" = 1'-0"
A1
13
A1
11
A1
11
A1
11
A1
11
A1
11
A1
11
A1
11
A-11
A1
13
A1
13
A1
13
A1
13
A1
13
A1
13
A1
13
A1
13
A7
24
A7
24
24
A7
24 24 24 24
21
A7
24
A7
24
24
A7
24
A7
24
24
24
A-24
A-13
24
A-33
B4
33
B4
33
B4
33
B4 B2 B4 B4
B4
A-12
12
12
12 12
12
12
EX1B
EX1B
33
EL-1 EL-1
EL-1 EL-1
WP4
WP4
A6 A6
A6 A6 A6
A6 A6 A6
A6
A6
A6 A6 A6
A6
A-2
2 2
2
22
2
2 2
2 2 2
2 2 2
2
2
2
222
33
EM2B
EM2B
EM2B
EM2B
EM2B
EM2B
EM2B
EM2B
33
33
12
11
11
24
24
24
SWITCH e
A7 A7
P1
WB1WB1
A-38
#10
#10
A-38
TL1
#10
A-38
TL1 TL1
OS2 OS2
P5
24
RT
EX1B
RT
RT
B4
33
B4
A2
21
21
T2
21
21
T2
21
A-21
SWITCH d
24
ROOF
ACCESS
B4
33
T2
A7
A7
A7 A7
A7
A7
A7 A7 A7
A7
A7
A7
A1
24
21
24
24 24
A7
24
24
24
B2
33
B4
33
SWITCH a
SWITCH b
SWITCH c
A-28
(TYP)
(TYP)
SHEET NAME
SHEET NUMBER
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: **/**/****
PROJECT NUMBER: *****
DRAWN BY:
CHECKED BY:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
2600
S
BRISTOL
ST
SANTA
ANA,
CA
92704
PROJECT TYPE:
00000
GLOBAL NEXT GEN 30
FREESTANDING
NEW
COMPANY/FRANCHISE
2022
NEW BUILD
2024
GLOBAL
SPRING 2023
NEW
GLOBAL NEXT GEN 30
E-1.0
LIGHTING PLAN
GENERAL NOTES
1. PROVIDE WARRANTY TO INCLUDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE
PARTS AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR
OWNER ACCEPTANCE OF COMPLETED PROJECT, WHICHEVER IS LATER.
2. COMPLETED INSTALLATION SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND FEDERAL
CODES AND ORDINANCES, INCLUDING NFPA-90A, NFPA-96 AND NFPA-101.
3. DUCTWORK SHALL BE MANUFACTURED AND INSTALLED PER SMACNA 1" PRESSURE CLASS
GUIDELINES AND DETAILS. DUCTWORK SIZES SHOWN INDICATE INSIDE CLEAR DIMENSIONS.
CONCEALED DUCTWORK SHALL BE INSULATED WITH 2" THICK DUCT WRAP (R-8 MIN). INSULATE
CEILING MOUNTED DIFFUSER BACKS. VAPOR BARRIER SHALL BE MAINTAINED CONTINUOUS AND
SEAMS SHALL BE SEALED. DUCTWORK SHALL BE INSTALLED ABOVE SUSPENDED CEILING
WHERE PROVIDED. EXPOSED DUCTWORK SHALL BE G90 GALVANIZED STEEL. CLEAN OFF
MARKS, APPLIED STICKERS AND RESIDUAL OIL. VINEGAR WASH BEFORE PAINTING OF DUCT.
4. CONNECT DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT USING MECHANICAL
FASTENERS WITH SEALS, MASTIC OR GASKETS.
5. SUPPLY AND RETURN AIR DUCT DROPS FROM HVAC EQUIPMENT SHALL BE ISOLATED FROM
UNIT VIBRATION WITH FLEXIBLE DUCT CONNECTORS.
6. INSULATED FLEXIBLE DUCT MAY BE USED IN MAXIMUM LENGTHS AS SPECIFIED FROM RIGID
METAL DUCT TO DIFFUSER CONNECTION. FLEXIBLE DUCT SHALL BE CLASS 1 FLEXIBLE AIR DUCT
WITH INSULATION AND VAPOR BARRIER, AND SHALL MEET UL 181.
7. WHERE PLENUM DIFFUSERS ARE CHOSEN WITH INTEGRAL BALANCING DAMPERS SPIN -IN
CONNECTIONS MAY EXCLUDE DAMPERS.
8. CONTRACTOR SHALL RECEIVE AND INSTALL ROOF MOUNTED CONDENSING UNITS. PROVIDE
MOUNTING RAILS. REFER TO STRUCTURAL PLANS FOR LOCATIONS OF ROOF MOUNTED
EQUIPMENT, CURB, AND RAIL DETAILS. EQUIPMENT SHALL BE MECHANICALLY FASTENED TO
RAILS. RAILS SHALL BE FASTENED TO STRUCTURE. STRUCTURE, CONNECTIONS, AND
SUPPORTS SHALL MEET STRUCTURAL WIND LOAD REQUIREMENTS. CONSULT STRUCTURAL
ENGINEER AS NEEDED TO DETERMINE REQUIREMENTS.
9. CURBS SHALL BE ONE PIECE WELDED AND INSULATED 18 GAUGE STEEL, WITH RIGID
INSULATION GLUED TO INSIDE OF CURB. REFER TO SHEET M2.0 FOR ADDITIONAL INFORMATION.
10. RETURN DUCTWORK FROM HVAC EQUIPMENT AND RECTANGULAR GENERAL EXHAUST
(RESTROOM) DUCTWORK SHALL BE LINED WITH 1" DUCT LINER.
11. PROVIDE STENCIL LABELS ON HVAC EQUIPMENT AND EXHAUST FANS. LABELS SHALL HAVE 2"
HIGH LETTERS ON UNIT SIDE ACCESS PANEL. EXPOSED GAS PIPING AND FITTINGS SHALL BE
PAINTED WITH SAFETY YELLOW PAINT DESIGNED FOR BLACK IRON.
12. ENSURE GAS LINES AND CONDENSATE DRAIN LINES DO NOT IMPEDE HVAC EQUIPMENT
DOORS/PANELS. FOLLOW MANUFACTURER GUIDELINES FOR REQUIRED CLEARANCES.
13. REFER TO "H" AND "W" SHEETS FOR SPECIFIC HOOD AND FAN INFORMATION AND FIELD WIRING
DIAGRAMS. CONTRACTOR SHALL PROVIDE LOW VOLTAGE WIRING FROM FAN CONTROL PANEL
TO HVAC EQUIPMENT, REMOTE SENSORS AND SMOKE DETECTORS. CONTRACTOR SHALL
PROGRAM THERMOSTAT FOLLOWING WENDY'S STANDARDS. REFER TO PROGRAMMING
INSTRUCTIONS PROVIDED WITH MODULAR PANEL SYSTEM.
14. CONTRACTOR SHALL TEST, CHECK, AND BALANCE HVAC EQUIPMENT, EXHAUST HOODS, AND
EXHAUST FANS. SET EXHAUST FANS AND DIFFUSERS TO SPECIFIED AIR FLOW RATES.
CONTRACTOR SHALL COMPLETE WENDY'S REQUIRED TEST FORMS FOR HVAC EQUIPMENT,
HOODS, AND FAN CONTROL SYSTEM. REFER TO M4.0 FOR TESTING AND BALANCE
REQUIREMENTS.
15. CONTRACTOR SHALL COMPLETE ROOFTOP UNIT START UP HVAC EQUIPMENT FORMS AND
RETURN TO MANUFACTURER TO SCHEDULE EQUIPMENT OPERATION CHECK (EOC). CONSULT
CONTACT OR ALLOW 5 BUSINESS DAYS TO SCHEDULE EOC. CONTRACTOR IS RESPONSIBLE FOR
CORRECTING DEFICIENCIES NOTED IN EOC PRIOR TO START OF TESTING AND BALANCING.
16. CONTRACTOR SHALL VERIFY THAT BUILDING IS WEATHER TIGHT, HVAC EQUIPMENT POWERED
AND CALIBRATED, THERMOSTATS PROGRAMMED, FANS OPERATIONAL, EOC COMPLETE,
DIFFUSERS AND CEILING TILE INSTALLED, EXHAUST FAN SPEEDS CALIBRATED, AND NEW
FILTERS INSTALLED IN HVAC EQUIPMENT PRIOR TO TESTING AND BALANCING. CONTRACTOR
SHALL CORRECT OPERATIONAL OR PERFORMANCE DEFICIENCIES FOUND DURING TESTING AND
BALANCING.
17. COMPLETE SMOKE CAPTURE TEST(S), AS REQUIRED, IN ACCORDANCE WITH INTERNATIONAL
MECHANICAL CODE IMC 507, ASHRAE 154 VENTILATION FOR COMMERCIAL COOKING
OPERATIONS, AND HOOD MANUFACTURER STANDARDS. KITCHEN EQUIPMENT SHALL BE AT
OPERATING TEMPERATURES WITH HVAC EQUIPMENT OPERATIONAL. TEST USING SMOKE
CANDLES OR SMOKE PUFFERS. SMOKE BOMBS SHALL NOT BE USED.
18. EQUIPMENT WITH SYMBOL TAGS ON PLANS, REFER TO ASSOCIATED EQUIPMENT SCHEDULES
FOR REQUIREMENTS. TAGGED EQUIPMENT IS RESPONSIBILITY OF CONTRACTOR TO PROVIDE
UNLESS OTHERWISE NOTED.
19. CONTRACTOR IS RESPONSIBLE FOR PROVIDING MANUAL BALANCE DAMPERS IN DUCT
BRANCHES IN ACCESSIBLE LOCATION ABOVE CEILING.
GREASE DUCTS NOTES:
1. FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE
LATEST MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF
ITS LISTING.
2. ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE
SHALL BE SEALED PER THE MANUFACTURER'S RECOMMENDATIONS.
3. ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION.
4. AT TIME OF INSPECTION, THE FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE
INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOB SITE.
FIRE NOTES:
1. FIRE DEPARTMENT APPROVAL SHALL BE REQUIRED ON FIRE PROTECTION SYSTEM FOR GREASE
HOODS AND DUCTS AS REQUIRED BY SECTION 513 OF THE CALIFORNIA MECHANICAL CODE AND
AS REQUIRED BY THE FIRE CODE.
2. ALL FIRE -EXTINGUISHING SYSTEMS SHALL BE INTERCONNECTED TO THE FUEL OR CURRENT
SUPPLY SO THAT THE FUEL OR CURRENT IS AUTOMATICALLY SHUT OFF TO ALL EQUIPMENT
UNDER THE HOOD WHEN THE SYSTEM IS ACTIVATED.
3. OWNER OF ESTABLISHMENT SHALL BE RESPONSIBLE FOR CLEANLINESS, MAINTENANCE, AND
INSPECTION OF KITCHEN EXHAUST SYSTEM, FIRE PROTECTION, AND COOKING EQUIPMENT.
4. A DRAWING OF THE EXHAUST SYSTEM(S) INSTALLATION ALONG WITH A COPY OF OPERATING
INSTRUCTIONS FOR SUBASSEMBLIES AND COMPONENTS USED IN THE EXHAUST SYSTEM(S),
INCLUDING ELECTRICAL SCHEMATICS, SHALL BE AVAILABLE ON THE PREMISES.
5. ALL SEAMS, JOINTS, AND PENETRATIONS OF THE HOOD ENCLOSURE THAT DIRECT AND
CAPTURE GREASE -LADEN VAPORS AND EXHAUST GASES SHALL HAVE A LIQUID TIGHT
CONTINUOUS EXTERNAL WELD TO THE LOWER OUTERMOST PERIMETER OF THE HOOD.
6. PRIOR TO THE USE OR CONCEALMENT OF A PORTION OF A GREASE DUCT SYSTEM, A LEAKAGE
TEST SHALL BE PERFORMED TO DETERMINE THAT ALL WELDED JOINTS AND SEAMS ARE LIQUID
TIGHT.
7. PERFORMANCE, CAPTURE AND CONTAINMENT TESTS SHALL BE PERFORMED UPON
INSTALLATION BEFORE FINAL. TEST DATA AND PERFORMANCE TEST RESULTS SHALL BE
DISPLAYED AND BE AVAILABLE UPON REQUEST.
8. HOOD EXHAUST FAN SHALL CONTINUE TO OPERATE AFTER THE EXTINGUISHING SYSTEM HAS
BEEN ACTIVATED, UNLESS FAN SHUTDOWN IS REQUIRED BY A LISTED COMPONENT OF THE
VENTILATION SYSTEM.
9. TYPE I HOODS SHALL BEAR A LABEL INDICATING THE EXHAUST FLOW RATE IN CUBIC FEET PER
MINUTE PER LINEAL FOOT.
10. LICENSED AIRFLOW CONTRACTOR SHALL PROVIDE GREASE EXHAUST SYSTEM AIR BALANCE
REPORT TO INSPECTOR PRIOR TO FINAL.
SYMBOLS & ABBREVIATIONS
LEGEND
OT
THERMOSTAT
AFF
O
TEMPERATURE/HUMIDITY SENSOR
AHJ
RT
REMOTE TEST STATION
CFM
®
DUCT SMOKE DETECTOR
EA
®
SUPPLY DUCT
ESP
RETURN DUCT
FCLC
®
EXHAUST DUCT
HZ
J
MANUAL BALANCE DAMPER
MOCP
NFPA
NC
SUPPLY DIFFUSER
OA
RETURN GRILLE
OAU
EXHAUST GRILLE
FTU
DUMP BOX DIFFUSER
SA
TYP
`EEET
SIDE WALL MOUNTED SUPPLY REGISTER
WC
ROOFTOP UNIT SCHEDULE HVC n
OUTSIDEAIR TEMPERATURE: 95°FSUMMER
S/A FAN
HEATING
HEATING
AFUE
COOLING
CA
WEIGHT
MANUFACTURER
UNIT
MODEL NO.
TONS
VOLT
INPUT
OUTPUT
%
OUTPUT
EER
IEER
MCA
MOCP
CFM
LBS
NOTES
BHP
CFM
ESP
TRANE
ALL AS
GAS HEAT
RTU-1
YHK090
7.5
1.2
3000
1.0
208/3/60
120 MBH
97.2 MBH
81
90 MBH
12.1
17.7
43
50
1200
1400
APPLICABLE
TRANE
ALL AS
GAS HEAT
RTU-2
YHK120
10
1.9
4000
1.0
208/3/60
150 MBH
121.5 MBH
81
120 MBH
11.6
16.3
57
80
1700
1700
APPLICABLE
UNITS ARE TO BE COMPLETE WITH THE FOLLOWING:
1. FACTORY CURBS FOR CONTRACTOR TO INSTALL. CURB HEIGHTS SHALL PROVIDE FOR LOCAL SNOW ACCUMULATION,
CURBS SHALL BE 14 INCHES HIGH MINIMUM. CONTRACTOR TO CONFIRM CURB HEIGHTS AND STRENGTH WITH
STRUCTURAL ENGINEER TO CONFORM TO LOCAL SNOW ACCUMULATION, SEISMIC AND WIND LOADS, INCLUDING
FASTENER CONSTRUCTION AND INSTALLATION METHODS.
2. FACTORY MOUNTED AND WIRED NON -FUSED DISCONNECT.
3. WEATHER HOOD WITH BIRD SCREEN AT UNIT OUTDOOR AIR INLET.
4. SET MINIMUM OUTDOOR AIR AS SPECIFIED ABOVE. OUTDOOR AIR DAMPER SHALL FULLY CLOSE ON UNIT SHUTDOWN.
5. VFD SUPPLY FAN WITH SINGLE ZONE VARIABLE AIR VOLUME CONTROL WITH OUTDOOR AIR CFM COMPENSATION.
6. FACTORY MOUNTED AND WIRED DRAIN PAN CONDENSATE OVERFLOW SWITCH.
7. OUTDOOR AIR ECONOMIZER WITH SINGLE ENTHALPY CONTROL AND ECONOMIZER FAULT DETECTION AND
DIAGNOSTICS. PROVIDE UNIT WITH BAROMETRIC RELIEF. PROVIDE POWER RELIEF WHERE LOCAL AHJ REQUIRES.
8. FACTORY INSTALLED NON POWERED CONVENIENCE OUTLET.
9. STAINLESS STEEL HEAT EXCHANGERS AND FULLY MODULATING GAS BURNERS.
10. LOUVERED CONDENSER COIL HAIL GUARD.
11. FACTORY INSTALLED HOT GAS REHEAT COIL FOR DEHUMIDIFICATION CONTROL.
12. REFER TO DRAWINGS G2.1 FOR MANUFACTURER CONTACT INFORMATION.
13. PROVIDE MERV-13 FILTERS.
FAN SCHEDULE (3-PLATEN GRILLE
SETUP)
ACCESSORIES
MARK
AIRFLOW
STATIC
PRESSURE
MOTOR
HORSEPOWER
ELECTRICAL
(VOLTAGE /
MODEL
WEIGHT
REMARKS
BACK
(CFM)
(IN.WC.)
(HP)
PHASE)
DRAFT
BIRD
DISCONNECT
SPEED
DIRECT
LBS
DAMPER
SCREEN
SWITCH
CONTROL
DRIVE
EF-1
1100
1.25
3/4
208/1
X
X
X
DU85HFA
90
1-3
EF-2
1500
1.25
3/4
208/1
X
X
X
DU85HFA
90
1-3
EF-3
300
0.340
1/6
115/1
X
I X
I X
X
X
DU10HFA
49
1A
1. FANS, CURBS, AND NFPA FAN HINGES AS APPLICABLE SHALL BE SUPPLIED AS PART OF EXHAUST HOOD PACKAGE.
2. PROVIDE UL APPROVED GREASE RATING.
3. EXHAUST FAN IS CONNECTED TO HOOD ON SWITCH. FAN SHALL
OPERATE AT ALL TIMES WHILE RESTAURANT IS OPEN.
4. FAN TO OPERATE FROM SMART BREAKER IN FCLC SYSTEM.
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
CUBIC FEET PER MINUTE
EXHAUST AIR
EXTERNAL STATIC PRESSURE
FAN CONTROL LIGHTING CONTROL
FREQUENCY
MAXIMUM OVERCURRENT PROTECTION
NATIONAL FIRE PROTECTION ASSOCIATION
NOISE CRITERIA
OUTSIDE AIR
OUTDOOR AIR UNIT
FAN TERMINAL UNIT
SUPPLY AIR
TYPICAL
WATER COLUMN
AIR CURTAIN SCHEDULE
ELECTRICAL
MANUFACTURER
AND
CFM
MAX
WEIGHT
NOTES
MODEL NUMBER
FPM
VOLTS
PHASE
MAX
AMPS
HP
LBS
WATTS
MARS
AC-1
1418
4865
120
1
510
5.1
1/2
70
1 AND 2
STD242
MARS
AC-2
1200
1800
120
1
-
2.4
1/6
40
1 AND 2
LPV248
NOTE: 1. INTERLOCK AIR CURTAIN WITH LIMIT SWITCH ON DOOR TO ACTIVATE THE AIR CURTAIN
WHEN DOOR OPENS. BY ELECTRICAL CONTRACTOR.
2. AIR CURTAIN SHALL PROVIDE AIR AT A VELOCITY OF AT LEAST 750 FEET PER
MINUTE MEASURED AT 3'-0" ABOVE THE FLOOR.
AIR DEVICE SCHEDULE
SYMBOLS & ABBREVIATIONS LEGEND
OT
THERMOSTAT
AFF
O
TEMPERATURE/HUMIDITY SENSOR
AHJ
RT
REMOTE TEST STATION
CFM
®
DUCT SMOKE DETECTOR
EA
®
SUPPLY DUCT
ESP
RETURN DUCT
FCLC
®
EXHAUST DUCT
HZ
MOCP
J
MANUAL BALANCE DAMPER
NFPA
NC
SUPPLY DIFFUSER
CA
z
RETURN GRILLE
OAU
EXHAUST GRILLE
FTU
II„ Ih
DUMP BOX DIFFUSER
SA
lur
TYP
rE=P
SIDE WALL MOUNTED SUPPLY REGISTER
WC
COMMERCIAL KITCHEN NOTES
HVAC, FIRE PROTECTION AND PLUMBING
CITY OF SANTA ANA
�v
ABOVE FINISHED FLOOR
AUTHORITY HAVIN
JURISDICTION
CUBIC FEET PER MINUTE
EXHAUST AIR
R P
EXTERNAL STATIC F
RESS[JREO
FAN CONTROL LIGH
ING CONTROL
FREQUENCY
MAXIMUM OVERCUF
RENT
��PROTECTION
r
dlf
NATIONAL FIRE PR
EC�ImClSl�IA
NOISE CRITERIA
Date.
OUTSIDE AIR
OUTDOOR AIR UNIT
FAN TERMINAL UNIT
SUPPLY AIR
TYPICAL
WATER COLUMN
NEW EQUIPMENT, PIPING, ETC. SHALL BE INSPECTED AND LOCATED BEFORE AND AFTER NEW CONSTRUCTION. DETAILS OF
PERFORMANCE/CONDITION/SIZING AND LOCATION SHALL BE SUPPLIED TO ENGINEER AND OWNER. AIR CAPACITIES FOR
SUPPLY AND EXHAUST SYSTEMS SHALL BE MEASURED AT GRILLES TO DETERMINE IF DESIGN AIR FLOW RATES NOTED ON
PLANS CAN BE MET. EXTRA WORK REQUIRED TO ABOVE MENTIONED SHALL BE DETERMINED PRIOR TO NEW CONSTRUCTION
CONTRACTOR TO ALLOW FOR INSPECTION IN THEIR PRICE INCLUDING WELD INSPECTIONS, AIR FLOW RATE MEASUREMENT,
SCANNING AND CAMERA SCOPE TO EXISTING BURIED DRAINS. NO EXTRAS SHALL BE ALLOWED ONCE NEW CONSTRUCTION
STARTS.
CONTRACTOR SHALL OBTAIN LATEST SPREAD SHEETS/SHOP DRAWINGS FROM KITCHEN CONSULTANT FOR APPLIANCE AND
HVAC REQUIREMENTS PRIOR TO ROUGH -IN WORK.
CONTRACTOR SHALL PROVIDE WIRING AND CONTROLS AS NOTED ON WIRING NOTES IN EQUIPMENT SCHEDULE.
CONTRACTOR SHALL:
1. CONSTRUCT ENTIRE KITCHEN HOOD EXHAUST SYSTEM TO NFPA 96 STANDARDS.
2. REFER TO ARCHITECTURAL AND/OR INTERIOR DESIGN DRAWINGS FOR HOOD LOCATION AND APPROVED KITCHEN HOOD
SHOP DRAWINGS FOR EXACT LOCATION OF EXHAUST DUCT CONNECTIONS.
3. REFER TO LATEST KITCHEN EQUIPMENT DRAWINGS AND APPROVED SHOP DRAWINGS FOR FINAL GAS, PLUMBING AND
DRAINAGE HOOK UP SIZES AND LOCATIONS. CONTRACTOR TO REFER TO MANUFACTURERS INSTALLATION MANUALS AND
RECOMMENDATIONS AND PROVIDE NECESSARY EQUIPMENT, VALVES, PIPING, ETC. TO SUIT. EXACT LOCATION OF
EQUIPMENT ROUGH -INS SHALL BE DETERMINED AT SITE. CHANGES TO KITCHEN EQUIPMENT LINE UP MUST BE REPORTED
TO ENGINEER, FOOD SERVICES VENDOR, AND ARCHITECT PRIOR TO INSTALLATION.
4. USE ONLY APPROVED (7APTIVFAIRF FAN AND HOOD PACKAGE.
5. ROOF MOUNTED FANS SHALL BE ACCESSIBLE ON SIDES ACCESSIBLE WITHOUT LADDER. REFER TO DETAILS.
ANSUL NOTES
THIS INSTALLATION SHALL BE PROVIDED IN ACCORDANCE WITH R-102 INSTALLATION MANUAL AND IN ACCORDANCE WITH
STATE AND LOCAL CODES. WIRE ROPE FOR DETECTOR AND REMOTE PULL STATION SHALL BE INSTALLED BY AN AUTHORIZED,
FACTORY TRAINED DISTRIBUTOR OR SERVICE REPRESENTATIVE. THIS INSTALLATION SHALL BE INSPECTED, PUT INTO
OPERATION AND CERTIFIED BY AN AUTHORIZED, FACTORY TRAINED DISTRIBUTOR OR SERVICE REPRESENTATIVE.
ELECTRICAL CONTACTS AND WIRING FOR APPLIANCE SHUT OFF SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. ANSUL
R-102 RESTAURANT FIRE SUPPRESSION SYSTEMS HAVE BEEN TESTED AND ARE LISTED BY UNDERWRITERS' LABORATORIES
INC. AS PRE-ENGINEERED SYSTEMS; SHALL COMPLY WITH RELEVANT ANSUL INSTALLATION RECHARGE INSPECTION AND
MAINTENANCE MANUALS; SHALL COMPLY WITH NFPA 96 WHEN INSTALLED AND CERTIFIED BY AUTHORIZED TRAINED ANSUL
DISTRIBUTORS. AGENT DISTRIBUTION PIPING AND DETECTION CONDUIT HOOD PENETRATIONS SHALL BE PROPERLY SEALED
IN ACCORDANCE WITH NFPA 96.
TYPE
ACCESSORY
MOUNT
DUTY
DIFFUSER
TITUS
PRICE MOEL
NECK SIZE
FACE SIZE
PATTERN
NOTES
MARK
MODEL NO.
NO.
DIFFUSER
REGISTER
GRILLE
OBD
STIR
TRM
LAY -IN
SURFACE
SUPPLY
RETURN
EXHAUST
RG-1
22"X22"
24"X24"
X
X
X
PERFORATED
X
PAR -AA
APDDR
1,2
RG-2
8"
12"X12"
X
X
X
X
PERFORATED
X
PAR -AA
APDDR
1,2 DRYWALL CEILING MOUNT EXHAUST
RG-3
52"X14"
54"X16"
X
X
X
X
NONE
X
35ORL
530L
1 DINING RETURN
SD-1
12"x12"
14"X14"
X
X
X
X
NONE
X
30ORL
600
1 DINING SUPPLY
1,3,4 CEILING MOUNTED HOOD
SD-2
22"X22"
24"X24"
X
X
PERFORATED
X
PAR -AA
APDDR
SUPPLY DUMP BOX
1,3 CEILING MOUNTED HOOD SUPPLY
SD-2a
22"X22"
24"X24"
X
X
PERFORATED
X
DUMP BOX (CAPTIVEAIRE MODEL DI-PSP)
1,3 CEILING MOUNTED HOOD SUPPLY
SD-2b
22"X22"
24"X24"
X
X
PERFORATED
X
_
DUMP BOX (HALTON MODEL KCD)
SD-3
PER PLAN
24"X24"
X
X
4 WAY
X
PAS -AA
APDN
1,2
S
lllSD-5
P L
1 1
Y
P A
APD
2 RY ALL CEILING MOUNTED SUPPLY
101,
24"0
X
XI
X
X
TMRA AA
1,2
ACCESSORY NOTE: OBD-OPPOSED BLADE DAMPER, STR-SQUARE TO ROUND TRANSITION, TRM- RAPID MOUNT SHEETROCK FRAME
AIR DEVICE SCHEDULE NOTES
1. WHITE
2. ROUND NECK
3. SUPPLY DIFFUSERS AT HOOD LOCATION USE SHOP OR FIELD FABRICATED DUMP BOXES, WHICH CONSIST OF PERFORATED DIFFUSER WITH NO PATTERN CONTROLLERS, AND
SQUARE PLENUM BOX THAT CAN ACCEPT ROUND DUCT CONNECTION. 4 WAY DIFFUSERS ARE PROHIBITED AROUND THE HOODS.
4. REFER TO DUMP BOX DETAIL ON DRAWING M2.0.
AIR FLOW SCHEMATIC
1100 CFM 1500 CFM
1700 CFM 300 CFM 1200 CFM
RTU-2 RTU-1
EF-1 EF-2 EF-3
2300 CFM 4000 CFM 1800 CFM 3000 CFM
AIR BALANCE SCHEDULE
MARK
SUPPLY
AIR
RETURN
AIR
EXHAUST
AIR
OUTSIDE
AIR
RESULTING
PRESSURE
EF-1
1100 CFM
-1100 CFM
EF-2
1500 CFM
-1300 CFM
EF-3
300 CFM
-300 CFM
RTU-1
3000 CFM
1800 CFM
1200 CFM
+1200 CFM
RTU-2
4000 CFM
2300 CFM
1700 CFM
+1700 CFM
AIR BALANCE REPORT REQUIRED. SEE SPECIFICATIONS. +200 CFM
BASE MDL: GLOBAL NEXT GEN 30
ASSET TYPE: FREESTANDING
nrlmraf] NEW
WNER: COMPANY/FRANCHISE
kw99 V R O : q
UPGRADE CLASSIFICATION:
NEW BUILD
PROJECT YEAR: XXXX
DESIGN TYPE: GLOBAL
DRAWING RELEASE: SPRING 2023
ARMED DAVIS NEWLOVE &
ASSOCIATES, AIA ARCHITECTS
1330 OLYMPIC BLVD.
SANTA MONICA, CALIFORNIA 90404
PH 310 452-5533 FAX 310 450-4742
L & D ENGINEERING
ENERGY &MECHANICAL SYSTEM CONSULTANT
1330 OLYMPIC BOULEVARD, #8
SANTA MONICA, CA. 90404
TEL: (310) 452-0575
FAX: (310) 450-4742
EMAIL: KAVEH@LANDDENGINEERING.COM
PROJECT TYPE: NEW
GLOBAL NEXT GEN 30
O
REV. DATE DESCRIPTION
1 02-27-25 REVISIONS
2 04-09-25 REVISIONS
ISSUE
DATE: 09-27-24
PROJECT NUMBER: -- 240902
DRAWN BY:
CHECKED BY:
SEAL
SHEET NAME
MECHANICAL SCHEDULESmi
SHEET NUMBER
00
CITY
OF SANTA ANA
Cy
® CODED NOTES.
SITE NUMBER: 00000
BASE MDL: GLOBAL NEXT GEN 30
1. INSTALL GREASE EXHAUST HOOD. SUPPORT HOOD PER MANUFACTURE
'S INSTALLATION
ASSET TYPE: FREESTANDING
INSTRUCTIONS. TRANSITION FROM HOOD COLLAR TO DUCT SIZE SHOWN.
TWO METHODS
LISTED BELOW ARE ALLOWED FOR GREASE DUCTWORK ASSEMBLIES. PL
EASE NOTE THAT
BOTH OPTIONS REQUIRE CLEANOUT ACCESS DOORS AT EVERY CHANGEIN
DUCT DIRECTION
I I NEW
WITH 3 FOOT CLEARANCE IN FRONT OF ACCESS DOORS.
WNER: COMPANY/FRANCHISE
1.1. PREFERRED METHOD: FACTORY MANUFACTURED UL2221 LISTED INS
EXHAUST DUCT SYSTEM WITH MANUFACTURER CLEANOUT ACCESS
ULA E
DOO FP E.
V R O 02
JAIW
SHEET M2.0 FOR ADDITIONAL INFORMATION. COORDINATE WITH GREASE
UC
MANUFACTURER IF FIRE WRAP IS REQUIRED.
UPGRADE CLASSIFICATION:
1.2. PROVIDE 16 GAGE CARBON STEEL GREASE EXHAUST DUCTWORKWELDED
LIQUID TIGHT
UP TO EXHAUST FAN. WRAP GREASE DUCT WITH COMPOSITE GREA
E DUCT ENCLOSURE
ASSEMBLY PER DETAIL 01/M2.0. GREASE DUCT ENCLOSURE SHALLAVE
AT LEAST AN F
NEW BUILD
OR T RATING OF ONE HOUR. INSTALL EXHAUST DUCT WRAP PER MA
UFACTURER'S
PROJECT YEAR: XXXX
INSTRUCTIONS. PROVIDE "FASTDOOR XL" GREASE DUCT CLEANOUT
CCESS DOORS(C.O.D)
MANUFACTURED BY THERMAL (OR ANCEAIN
9ULENT) T �j
N-0 D
DESIGN TYPE: GLOBAL
DIRECTION IN DUCT. ROVIDE MINIMUM 3FEET CLEEARAMICS
FRO
T .
INSULATE ACCESS DOORS TO MAINTAIN RATINGS OF GREASE DUCT
ENCLOSURE PER
DRAWING RELEASE: SPRING 2023
FIRE PROTECTION INSULATION MANUFACTURER'S INSTRUCTIONS.
Date_
2. PROVIDE COMBINATION AUDIO/VISUAL ALARM AND REMOTE TEST STATI
N (SYSTEM SENSOR
RTS2). MOUNT 54" ABOVE FINISHED FLOOR AND PROVIDE LABEL NAMEPLIATE
WITH 1/2 HEIGHT
LETTERING (BLACK ON WHITE) FOR WHICH UNIT IT MONITORS. INSTALLA
ION SHALL MEET
CRITERIA AS PRESCRIBED IN NFPA 90A AND NFPA 72.
3. PROVIDE ROOFTOP UNIT AND CURB COORDINATED WITH STRUCTURE. SHIM UNIT AND CURB
LEVEL FOR PROPER CONDENSATE DRAINAGE. PROVIDE FLEXIBLE CONNECTORS ON SUPPLY
AND RETURN AIR DUCT CONNECTIONS. TRANSITION TO DUCT SIZES SHOWN. SECURE
EQUIPMENT TO CURBS PER MANUFACTURER'S RECOMMENDATIONS AND AS DETAILED. REFER
TO SHEET M2.0 FOR ADDITIONAL INFORMATION.
4. CONTRACTOR SHALL INSTALL GRIDPOINT/ENERGYBOX THERMOSTATS TO CONTROL ALL HVAC
UNITS. CONTRACTOR SHALL INSTALL GRIDPOINT/ENERGYBOX (ZONE SENSING MODULES) IN THE
CORRECT HVAC ZONES TO REPORT ZONE TEMPERATURE AND CONNECT TO EACH ZONES
THERMOSTAT T1 INPUT AS SHOWN. SENSOR 60" ABOVE FINISHED FLOOR. INSULATE EXTERIOR
WALL BEHIND REMOTE SENSORS ON EXTERIOR WALLS AND CAULK WIRE PENETRATION THROUGH
WALL. RUN CAT5E CABLE FROM TS150-1 TO TS150-2. LEAVE 8" OF CABLE COILED/ACCESSIBLE IN
BOTH REMOTE SENSORS ON EXTERIOR WALLS AND CAULK WIRE PENETRATION THROUGH WALL.
5. PROVIDE DUCT MOUNTED SMOKE DETECTOR AND SENSING TUBE, AND INTERLOCK TO SHUT ARM ET DAVIS NEWLOVE &
DOWN ROOFTOP UNIT ON DETECTION OF SMOKE, ASSOCIATES, AIA ARCHITECTS
6. PROVIDE CURB AND ROOF MOUNTED EXHAUST FAN. ENSURE THAT TOP OF EXHAUST FAN IS 1330 OLYMPIC BLVD.
MINIMUM 40" ABOVE ROOF SURFACE. REFER TO SHEET M2.0 FOR ADDITIONAL INFORMATION. SANTA MONICA, CALIFORNIA 90404
7. PROVIDE CURB AND ROOF MOUNTED EXHAUST FAN. REFER TO SHEET M2.0 FOR ADDITIONAL PH 310 452-5533 FAX 310 450-4742
INFORMATION.
8. UNDERCUT DOOR 1" FOR TRANSFER AIR.
9. LOCATE SMOKE DETECTOR DOWNSTREAM OF RETURN AIR TAP CONNECTIONS. LI & D ENGINEERING
^ I G I^ I C C D I^ I G
10. PROVIDE DUCTLESS SPLIT SYSTEM AND CONDENSING UNIT. REFER TO SHEET M3.0
FOR SCHEDULE INFORMATION. ENERGY &MECHANICAL SYSTEM CONSULTANT
1330 OLYMPIC BOULEVARD, #8
11. CONTRACTOR SHALL INSTALL GRIDPOINT TEMPERATURE PROBES IN EACH HVAC SUPPLY DUCT 1330A LYMPICMONICA, CA. BOULEVARD,
TO REPORT DISCHARGE AIR TEMPERATURE AND CONNECT TO EACH ZONES THERMOSTAT T2
90404
INPLILLAS SHOWN. TEL: (310) 452-0575
12. EXPOSED DINING ROOM DUCTWORK AND DIFFUSERS VISIBLE TO THE PUBLIC SHALL BE PAINTED FAX: (310) 450-4742
TO MATCH CEILING. EMAIL: KAVEH@LANDDENGINEERING.COM
CONTRACTOR TO MAKE SURE 9" (I.D.) DUCT WILL PASS THROUGH TRUSS OPENING BEFORE
INSTALLATION OF DUCTS AND NOTIFY ENGINEER TO CHANGE IT TO 8" TO ADD MORE DIFFUSERS.
13. E G T BE CA IN M FIT. MO T OM OF LE 10'-
A.F.F. PROJECT TYPE: NEW
14. CTs WILL BE FURNISHED BY THE EMS CONTRACTOR FOR INSTALLATION BY THE ELECTRICAL GLOBAL NEXT GEN 30
CONTRACTOR. FINAL CONNECTIONS TO THE EMS SYSTEM SHALL BE COMPLETED BY THE
EMS CONTRACTOR.
HVAC BIDDING AND EQUIPMENT NOTES
FOR QUOTATION ON THIS EQUIPMENT, REFER TO APPROVED VENDOR LIST ON SHEET G2.1:
EQUIPMENT PACKAGE:
RTU-1 AND RTU-2 WITH ACCESSORIES AND CURBS:
GENERAL CONTRACTOR TO CONTACT APPROVED VENDOR ON SHEET G2.1 FOR PRICING
INFORMATION. IF DESIGN CONDITIONS DIFFER FROM THOSE LISTED, CONTACT SUPPLIER
FOR APPROPRIATE EQUIPMENT.
HOODS, FANS AND FAN CURBS PACKAGE:
GENERAL CONTRACTOR TO CONTACT APPROVED VENDOR ON SHEET G2.1 FOR PRICING
INFORMATION. CURBS SHALL BE INSULATED AND TO COMPLY WITH NFPA 96
REQUIREMENTS FOR HEIGHT. CURBS PROVIDED FOR EF-1 AND EF-2 MUST BE HINGED.
AIR DISTRIBUTION PACKAGE:
PACKAGE TO INCLUDE SCHEDULED AIR DEVICES AND ACCESSORIES. EQUIPMENT AND
MATERIAL PACKAGES ARE IN STOCK AND SHOULD BE ORDERED IMMEDIATELY UPON
RECEIPT OF HVAC CONTRACT TO AVOID CONSTRUCTION DELAY. CONTACT HJC CONSOLIDATOR
FOR DIFFUSER PACKAGE.
O
P�
V )
J Q
O(
U)Q
ryZ
''m
VJ
o
Z
cal Cn
REV. DATE DESCRIPTION
1 02-27-25 REVISIONS
2 04-09-25 REVISIONS
ISSUE DATE: 09-27-24
PROJECTNUMBER:- 240902
DRAWN BY:
CHECKED BY:
SEAL
LSS/�
Al AA
W25955
� 6-
\9tF n N
SHEET NAME
HVAC PLAN
SHEET NUMBER
M2.0