2350 S Pullman St - DEF - Mechanical Rooftop Equipment Support - Plan
CITY OF SANTA ANA i i o To im no, I NU re na OvAizz 1� � M M)MicroMetl 4M Submitted to: Date RTU Weight: 1351bS (Us) 61.24kq (Metric) � Part Number: CRBK=PR20BHAm1 411 Notes: Knockdown Structurally Calculated Curb - 14 Inches Tall Non Insulated Full Perimeter Knockdown Structurally Calculated Curb, California S High Seismic Criteria, Includes Hold -Down Brackets "Structurally Starnped Bv A Professional Engineer. Without Pitch,structurally ped yA Professional Engineer Without , Approved by: Approved ANC """'-,,, InsulateDeckPant to Standard, Insulated Deck Pan I Oppird�ble�� � �- Includes Wood Nailer & Hold Down Brackets,, Meets Seismic Requirements for 2022 CBC & 2021 IBC. Wind Design Criteria: 60 Foot Tall BuiIBMg Maximum, Exposure C, 155 MPH -3 Second Gust Speed, Risk Category III & IV. FORM NO.: 49 375 TOP CID 8.625 4X 46.375 � 1. D. i 63.500 TOP 4.D o0.s00 � I.D j 52.375 BOTTOM O. D �- -tp•15 .r -Ss='50 / -rig 11 WIND DESIrIJ C ITERIA - 60 FT. TALL BUILDING kAA_XN - EXPOSURE C CURB MICROHOLD REQUIREME�JTS - 155 MPH, 3-SECOtID GJST 1AI ND► JP EED - (a. - RISK CATEGORY III & 17 - (O 1 MICROHOLD S P ER SIB CART S IDE •NI "•ayeIPCI PPrrJj,r-T :•E N T �r,ll _►f P*I!C'J r -►,E � Cry :EgtiICE tle i 1.b00—� 1 OOQ 8.000 11,000 14.000 CURB END DETAIL 14 UA MIC.KUhLXU ATTACH TO CURE W1 (3) ff1Qx112 TEK SCREWS SECURE TO UNIT WI , (3) X1�x1.112 TEK SCREWS CURB EI4DS AND SIDES ARE ATTACHED `VI TH TABS - 8" 16 GA CURB FRAf�AE _._--- 1 1" 16 GA CURB FRAME- 14` IC CAA CURS FRAMr- - "^ KNOCK DOWN CURB CORNER DETAIL s TRllt: TURJIi. LY CJ►l.< VI.A TED • • CRBK-PR2091-�A-UB Sorto; OQ�' TALL 108 LBS KNOCK Cf��VY�i C'Vti�] M i roM ti Co P orn,...tion CR8K-�'R208HA-11 Sines I I" TALL 120 LBS CRBK -P R20 6HA -1 a S e ripe s 1.!" T ALL 135 LB S M" UNIT 1�10"T 102 an IIIIA N C H G R A G E DETAILS TO ROOF ; c TAI ca.a T .►��� ► �.:: ��� : c � �� �.1� L� � :� I'• t.�►TF .� •�� _� .� r `�. nr o r►pe CW A�a� � IECA 4A T?e CV�l TO �%%. %AM "W AN � Wn TY�'1cALt'LAd YiEYY QTEFL a TTA - LiJ4t�kt' /nd rJr�.� pol,s, 1 N �� C�0 J 66�-�8?? ,� FAA f P ti � OTHERS) ! CURB !�S CURS t REF Ck�L�IC=L4�S FAR t , _ .`1 Jf �Il,�l T?�� ��� a all* j fl-E c v11o�OD OR (4' 416V ECV%E rvs rAmLIE "4r L sp...� s Pev (60a/ 884.462 WTA` ��t (38) 1140 x TO SIMPSON SOS Al, • ,� 1 r8 �• WASHM CENTERED ON 1141 1 ':"' 51W S �N TiTT'V ► O Longriaw, fx 40 3) 24041700 I D iC LI R 8 C' 1 to A F'1 �N� :� r r- N T�t1(1N ri IRR F I AMIr 0) EACH LL 1 S VE Ir MINI L%M SPAC 40 1-' - - 8€A�A'I 3) EACH SNORT 50E (�1 EACH LOW S" L?i'tJ11rY�� I ' C �► ~ p i ', Z R F D CAA4 (1) QNC H CIORN IGR i I 1� C►+ GNO RT C IM • • 1" (2) EACH C C RNE R �, w I D 003' frn SOS, CURB - MEET S S E 151KI _ I I Z) A �01 t 2' D+A !'lC�LT� . CUA 0 e REOiJ�R E�II E HT 5 FORt � r i Z) /13Q7' I . ? Q A 801. T ,,. •.'Y1 wa HER (-FNTFRFD CLO-OPTION VVI WASHER CENTERED SLAB� 2022 Ctx. & 2021 16C ru OPJ FL.Ia NNGE ..... _.. --- !- 5'► LONG t�9' FILLET WELDS O!`I FLANOE MEETS REOIJiiE�AENTB FOR . � ��1 �� LONE SIDE AHD rt►cMI i � ku I u at wrU i 1 � tom.►+ Lun,U �iV� 155 MPN. 1 EACH SHORT SIDE irl PLACE OF EACH 8017 1) EACH SHORT �IpE i0' [3UILGING NEK3Ftf MAX . • • • . ��� �� COpNGR iNflK`.A�rcn av TMc 1� CAC:N f'PIRNFR �� 3 SEC GUST El(P C c � SPACI�JO � CORNER � � r STf:, 1. ATTACHMENT DETAIL a ■T '►' AF r o � 4' EQUALLY SPACED o ■ C' IlRbi y - " = This Document Is The Property Of MlcroMr►tt CarporaUonMd Is Delivered Upon the Exprnn� Condition lhnl lho C�mtanls Will N, it IIN Unclosed t"h thnn�1 Wilh��ut MucioMutl'� IM1Mtten Consent Muter Rc�viston MluoMetl Rusc!rvog The Right to DlscnnUnuo, (fir Chonyo /1t Any limn, fipo��iflco11on4 8 lMpigne V✓iIl�i��il Any Notice Im urnn� ( ►blio��flnme paflo Rovigioi� Indianapolis 3035 N. Shadeland Ave., Indianapolis, IN 46226-800MMIC.HVIIAC •a SPflrk5 905 Southeill Wily, SpalkS, NV 89431 800 884 4MMC •• Longview.201 Kodak Blvd., Longview. IX 75602903 248 4800 MICROHOLD DETAIL UNIT TO CURB ATTACHMENT DETAIL UNJ T F-h CC RIEW ' UN irs :E RAIL TMSCMW ;RO*aLO QU NAILth 000 1 A 0001 A 4' E ABBREVIATIONS AD - ACCESS DOOR AFF - ABOVE FINISHED FLOOR ABS - ABSOLUTE AVTR - ACID VENT THRU ROOF ALT - ALTITUDE AMB - AMBIENT ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE APPROX. - APPROXIMATE ATM - ATMOSPHERE ATC - AUTOMATIC TEMPERATURE CONTROL AUX - AUXILIARY AVG - AVERAGE AWT - AVERAGE WATER TEMPERATURE BFD - BOILER FEED DISCHARGE BFW - BOILER FEED WATER BOD -BOTTOM OF DUCT BOPI - BOTTOM OF PIPE INSULATION BOT. - BOTTOM BHP - BRAKE HORSEPOWER BMS - BUILDING MANAGEMENT SYSTEM BSV - BLEED SOLENOID VALVE BTU - BRITISH THERMAL UNIT CL - CENTER LINE CU FT - CUBIC FEET CU IN - CUBIC INCH CFM - CUBIC FEET PER MINUTE CFH - CUBIC FEET PER HOUR COMPR - COMPRESSOR C.O. - CLEAN OUT CP - CEILING PENETRATION CWP - COLD WORKING PRESSURE CR - CONTROL RELAY CV - CONTROL VALVE CYL - CYLINDER DB - DIFFUSER BOX DFU - DRAINAGE FIXTURE UNITS DIA. - DIAMETER ID - DIAMETER, INSIDE OD - DIAMETER, OUTSIDE DISCH - DISCHARGE DN - DOWN DSV - DRAIN SOLENOID VALVE DWG. - DRAWING D.B. - DRY BULB EAT - ENTERING AIR TEMPERATURE EEW - EMERGENCY EYE WASH E.C. - ELECTRICAL CONTRACTOR ENT - ENTERING ER - EXHAUST REGISTER EWT - ENTERING WATER TEMPERATURE EWC - ELECTRIC WATER COOLER EQ - EQUALIZER ESP - EXTERNAL STATIC PRESSURE F - FAHRENHEIT FD - FIRE DAMPER (RATING, HRS.) FLA - FULL LOAD AMPS FT - FEET FPM - FEET PER MINUTE FPS - FEET PER SECOND FRD - FIRE RATED DAMPER FPT - FEMALE PIPE THREAD FS - FLOAT SWITCH FCO - FLOOR CLEANOUT GA. - GAGE OR GAUGE GAL. - GALLON GP - GLYCOL PUMP GPM - GALLON PER MINUTE GPRV - GAS PRESSURE REDUCING VALVE GALV. - GALVANIZED H-O-A - HANDS-OFF-AUTOMATIC SWITCH HLA - HIGH LEVEL ALARM HLS - HIGH LEVEL STOP HP - HORSEPOWER H.R. - HOSE REEL HGSV - HOT GAS SOLENOID VALVE HR - HOUR RH - RELATIVE HUMIDITY IH - INTAKE HOOD INCLR - INTERCOOLER INV. - INVERT IPS - IRON PIPE SIZE KW - KILOWATT LAT - LEAVING AIR TEMPERATURE LWT - LEAVING WATER TEMPERATURE LG - LENGTH LL - LIQUID LEVEL LF - LINEAR FEET LLC - LIQUID LEVEL CONTROLLER LIQ - LIQUID LI - LIQUID INJECTION LSV - LIQUID SOLENOID VALVE LDTCO - LOW DISCHARGE TEMPERATURE CUTOUT LLA - LOW LEVEL ALARM LLS - LOW LEVEL STOP LPL - LOW PRESSURE LIQUID LPR - LOW PRESSURE RECEIVER LTRL - LOW TEMPERATURE RECIRCULATED LIQUID LTRS - LOW TEMPERATURE RECIRCULATED SUCTION MPT - MALE PIPE THREAD MAV - MANUAL AIR VENT MAX. - MAXIMUM MBH - 1,000 BTU's / HR M.C. - MECHANICAL CONTRACTOR MEZZ. - MEZZANINE MIN. - MINIMUM MOD - MOTOR OPERATOR DAMPER MS - MOTOR STARTER MTR - MOTOR NPS - NATIONAL PIPE-STRAIGHT NPT - NATIONAL PIPE-TAPERED N.O. - NORMALLY OPEN N.C. - NORMALLY CLOSED NTS - NOT TO SCALE NO - NUMBER ODF - COPPER TUBE DIMENSIONS -MALE END ODS - COPPER TUBE DIMENSIONS -FEMALE END OP - OIL POT O.C. - ON CENTER OZ - OUNCE OPL - OPERATING LEVEL O.A. - OUTSIDE AIR OAI - OUTSIDE AIR INTAKE ODT - OUTSIDE DIAMETER TUBING PH - PHASE PW - PLANT WASTE PSI - PRESSURE PER SQUARE INCH P.O.C. - POINT OF CONNECTION PRESS - PRESSURE PSIG - PSI GAGE P - PURGE PS - PURGE SUCTION / PRESSURE SWITCH PSV - PURGE SOLENOID VALVE RB - RETURN BOX R.C. - REFRIGERATION CONTRACTOR RP - ROOF PENETRATION RV - RELIEF VENT R.A. - RETURN AIR RPM - REVOLUTIONS PER MINUTE SCH - SCHEDULE SCR - SCREWED SOCL - SCREW OIL COOLING LIQUID SOV -SHUT-OFF VALVE S.W. - SITE WORK CONTRACTOR SV - SOLENOID VALVE SW - SOCKET WELD STL - STEEL S.S. - STAINLESS STEEL S.P. - STATIC PRESSURE SSV - SUCTION SOLENOID VALVE S.A. - SUPPLY AIR TEMP - TEMPERATURE TS - TEMPERATURE SENSOR T-STAT - THERMOSTAT T - THERMOSTAT TC - THERMOCOUPLE TX - THERMAL EXPANSION THK - THICK (-NESS) T.G. - TOP OF GRATE T.O.T. - TOP OF TRAPEZE TRANS. - TRANSITION TD - TEMPERATURE DIFFERENCE TSV - TRANSFER SOLENOID VALVE TYP - TYPICAL U/C - UNDERCUT (DOOR) UC - UNDERCUT (DOOR) U.F. - UNDERFLOOR UH - UNIT HEATER VAC - VACUUM VAR - VARIABLE VAV - VARIABLE AIR VOLUME VEL - VELOCITY VSV - VENT SOLENOID VALVE VERT - VERTICAL VISC - VISCOSITY V - VOLT VD - VOLUME DAMPER VOL - VOLUME VTR - VENT THRU ROOF W - WATT WCO - WALL CLEANOUT W/ - WITH W.B. - WET BULB YCO - YARD CLEANOUT ACP -AIR COMPRESSOR AD -AIR DRYER ADV -AUTOMATIC DRAIN VALVE AF -AIR FILTER AHU -AIR HANDLING UNIT AIH -AIR INTAKE HOOD AIRC -AIR CURTAIN AFMS -AIR FLOW MEASURING STATION AR -AIR RECEIVER ARH -AIR RELIEF HOOD AS -AIR SEPARATOR AU -AIR UNIT BB -ELECTRIC BASEBOARD HEATER BFP -BOILER FEED PUMP CF -CIRCULATION FAN CH -CHILLER COND -CONDENSER CP -CONDENSATE PUMP CUH -CABINET UNIT HEATER CWP -CHILLED WATER PUMP CV -CONTROL VALVE DCP -DOMESTIC WATER PUMP DHU -DEHUMIDIFICATION UNIT EC -EVAPORATIVE CONDENSER EDH -ELECTRIC DUCT HEATER EF -EXHAUST FAN EIH -ELECTRIC INFRARED HEATER ET -EXPANSION TANK EUH -ELECTRIC UNIT HEATER EWH -ELECTRIC WALL HEATER GUH -GAS UNIT HEATER HB -HOSE BIBB HPR -HIGH PRESSURE RECEIVER HX -HEAT EXCHANGER L -WALL LOUVER MAU -MAKE-UP AIR UNIT OP -OIL POT P -PUMP PP -PLUMBING PUMP PR -PUMP RECEIVER RC -REFRIGERATION COMPRESSOR RTU -ROOF-TOP UNIT RP -REFRIGERATION PUMP SF -SUPPLY FAN SP -SUMP PUMP SS -SPLIT SYSTEM AIR CONDITIONER VAV -VARIABLE AIR VOLUME UNIT WH -WATER HEATER WP -WATER PUMP WS -WATER SOFTENER MECHANICAL EQUIPMENT CALLOUTS 1. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS OR SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES OR REGULATIONS OF FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION IN EFFECT ON THE DATE MECHANICAL PACKAGE IS ISSUED. 2. WHERE APPROVED STANDARDS HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITER'S LABORATORY, AMERICAN CODES, ASA, ASHRAE, ARI, NEC, STATE FIRE INSURANCE REGULATORY BODY, NFPA OR OTHERS, THESE STANDARDS SHALL BE FOLLOWED WHETHER OR NOT INDICATED ON THE DRAWINGS AND SPECIFICATIONS. 3. ARRANGE WITH AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES AND SERVICE CONNECTIONS. VERIFY LOCATIONS AND ARRANGEMENTS AND PAY ALL CHARGES, INCLUDING INSPECTIONS. 4. WORKING PRESSURE OF PIPING SYSTEMS AND EQUIPMENT HAS BEEN ESTABLISHED AT 150 PSIG. 5. INSTALL PIPING AND DUCTWORK TO PROVIDE THE MAXIMUM POSSIBLE CLEAR HEIGHT UNDERNEATH UNLESS OTHERWISE NOTED. 6. THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT SHALL OPERATE WITHOUT OBJECTIONABLE VIBRATION OR NOISE. 7. INSTALL ALL THERMOSTATS 60" ABOVE FINISHED FLOOR TO CENTER OF OUTLET BOX IN WAREHOUSE AREAS. IN OFFICE AREAS MOUNT THERMOSTATS AT THE SAME ELEVATION AS THE LIGHT SWITCH (48" ABOVE FINISHED FLOOR TO CENTER OF BOX OUTLET). MOUNT THERMOSTAT 3" FROM LIGHT SWITCH. COORDINATE LOCATION AND MOUNTING HEIGHTS WITH ELECTRICAL CONTRACTOR PRIOR TO ROUGH-IN. 8. DUCT DIMENSIONS SHOWN ARE AIR STREAM SIZES (FREE AREA). SIZES DO NOT INCLUDE ALLOWANCE FOR DUCT INSULATION. PROVIDE SLEEVES AND INSERTS AS NECESSARY TO THE BUILDING CONTRACTOR FOR PLACEMENT IN STRUCTURAL WORK. 9. ROOF OPENING SIZES SHOWN FOR ROOFTOP A/C UNITS AND EXHAUST FANS ARE APPROXIMATE. CONTRACTOR SHALL PROVIDE EXACT ROOF OPENING, CURB SIZE, EQUIPMENT WEIGHTS, AND LOCATION REQUIREMENTS TO GENERAL CONTRACTOR. 10. CONFLICTS BETWEEN HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SHALL BE COORDINATED THROUGH CONSTRUCTION MANAGEMENT NO ARBITRARY CHANGES IN SYSTEMS LAYOUT SHALL BE APPROVED. 11. PIPING, VALVES, LIGHT FIXTURES, AND OTHER COMPONENTS ARE SHOWN LARGER THAN ACTUAL SIZE. PIPE ROUTING IS SHOWN WITH AN EXAGGERATED SPACING FOR CLARITY. ACTUAL PLACEMENT OF PIPING SHOULD BE DONE COLLECTIVELY AND IN SUCH A MANNER AS NOT TO CONFLICT WITH LOCATION SENSITIVE COMPONENTS SUCH AS LIGHT FIXTURES. 12. CAULK AND SEAL ALL WALL PENETRATIONS. WHERE PIPE OR DUCT PASS THROUGH FIRE RATED WALLS, PARTITIONS, CEILING, OR FLOORS, THE FIRE RATED INTEGRITY SHALL BE MAINTAINED. REFERENCE BUILDING DRAWINGS 13. PIPING FOR CONDENSATE SHALL SLOPE NOT LESS THAN 1/4 INCH PER FOOT. 14. DUCT PRESSURE CLASS: 1 INCH UNLESS NOTED OTHERWISE. MECHANICAL GENERAL NOTES: A -COMPRESSED AIR ATV -ATMOSPHERIC VENT AV -ACID VENT AW -ACID WASTE BBD -BOILER BLOWDOWN BD -BOOSTER DISCHARGE BF -BOILER FEED CBBD -CONTINUOUS BOILER BLOWDOWN C -CONDENSER WATER SUPPLY CD -CONDENSATE DRAIN CF -CHEMICAL FEED CHPL -CHILLED HIGH PRESSURE LIQUID CHWR -CHILLED WATER RETURN CHWS -CHILLED WATER SUPPLY COND -CONDENSATE CR -CONDENSER WATER RETURN CTWR -COOLING TOWER WATER RETURN CTWS -COOLING TOWER WATER SUPPLY CW -DOMESTIC COLD WATER SUPPLY CWR -CHILLED WATER RETURN CWS -CHILLED WATER SUPPLY D -DRAIN DC -DEFROST CONDENSATE E -EQUALIZER E-(NAME)-EXISTING PIPING ES - ECONOMIZER SUCTION FM -FORCED MAIN FOD -FUEL OIL DISCHARGE FOG -FUEL OIL GAGE FOR -FUEL OIL RETURN FOS -FUEL OIL SUCTION FOV -FUEL OIL TANK VENT FW -FEEDWATER GAS -GAS (NATURAL) GR - GLYCOL RETURN GS - GLYCOL SUPPLY GWR -GLYCOL WATER RETURN GWS -GLYCOL WATER SUPPLY HHWR -HEATING HOT WATER RETURN HHWS -HEATING HOT WATER SUPPLY HOR -HYDRAULIC OIL RETURN HOS -HYDRAULIC OIL SUPPLY HPC -HIGH PRESSURE CONDENSATE RETURN HPS -HIGH PRESSURE STEAM HPHR -HIGH PRESSURE DOMESTIC HOT WATER RETURN HPHS -HIGH PRESSURE DOMESTIC HOT WATER SUPPLY HPWR -HEAT PUMP WATER RETURN HPWS -HEAT PUMP WATER SUPPLY HPL -HIGH PRESSURE LIQUID HSD -HIGH STAGE DISCHARGE HSS -HIGH STAGE SUCTION HTRL -HIGH TEMPERATURE RETURN LIQUID HTRS -HIGH TEMPERATURE RETURN SUCTION HGD -HOT GAS DEFROST H -HUMIDIFICATION LINE HTWR -HIGH TEMPERATURE HOT WATER RETURN HTWS -HIGH TEMPERATURE HOT WATER SUPPLY HW -DOMESTIC HOT WATER SUPPLY HWR -DOMESTIC HOT WATER RETURN IBBD -INTERMITTENT BOILER BLOWDOWN IPL -INTERMEDIATE PRESSURE LIQUID ISD -INTERMEDIATE STAGE DISCHARGE ISS -INTERMEDIATE STAGE SUCTION IWR -ICE WATER RETURN IWS -ICE WATER SUPPLY LD -LIQUID DRAIN LI - LIQUID INJECTION LIQ -LIQUID LL -LIQUID LEVEL LPC -LOW PRESSURE CONDENSATE RETURN LPS -LOW PRESSURE STEAM LSS -LOW STAGE SUCTION LTRL -LOW TEMPERATURE RECIRCULATED LIQUID LTRS -LOW TEMPERATURE RECIRCULATED SUCTION MPC -MEDIUM PRESSURE CONDENSATE RETURN MPS -MEDIUM PRESSURE STEAM MTWR -MEDIUM TEMPERATURE HOT WATER RETURN MTWS -MEDIUM TEMPERATURE HOT WATER SUPPLY N2 -NITROGEN OR -OIL RETURN OS -OIL SUPPLY PC -PUMPED CONDENSATE PCR -PUMPED CONDENSATE RETURN PCHWR -PROCESS CHILLED WATER RETURN PCHWS - PROCESS CHILLED WATER SUPPLY PN -PNEUMATIC TUBE PO -PUMP OUT PW -PROCESS WASTE PW-SS -PROCESS WASTE -STAINLESS STEEL RD -REFRIGERANT DISCHARGE RL -REFRIGERANT LIQUID RS -REFRIGERANT SUCTION RV -RELIEF VENT RWC -RAIN WATER CONDUCTOR SAN -SANITARY SEWER SCL -SUB-COOLED LIQUID SS -STORM SEWER ST -STEAM SUCT -SUCTION SR -SUCTION RETURN SW -SOFT WATER THW -TEMPERED HOT WATER TSR -THERMOSYPHON RETURN TSS -THERMOSYPHON SUPPLY TWS -TOWER WATER SUPPLY TWR -TOWER WATER RETURN V -VENT PIPING VAC -VACUUM (AIR) VPD -VACUUM PUMP DISCHARGE W -WATER WR -WATER RETURN WS -WATER SUPPLY WW -WELL WATER MECHANICAL PIPING CALLOUTS 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL OPENINGS REQUIRED FOR PENETRATIONS THROUGH THE BUILDING EXTERIOR, INTERIOR, AND STRUCTURE. SEE "I-SERIES" PENETRATION DRAWINGS FOR PENETRATION DETAILS AND SEE SPECIFICATIONS TO BE USED IN CONJUNCTION WITH THE CONSTRUCTION DOCUMENTS FOR A COMPLETE INSTALLATION OF THE PENETRATION DETAIL. GENERAL CONTRACTOR TO COORDINATE PENETRATION WORK BETWEEN THE CONTRACTOR RESPONSIBLE FOR A COMPLETE INSTALLATION AND FOR A COMPLETE WEATHER-TIGHT AND VAPOR-TIGHT ENCLOSURE OF THE EXTERIOR, INTERIOR, AND FOOD SAFE ENVIRONMENTS. PENETRATION DETAILS TYPE D -ELASTOMERIC FOAM, ‘ARMAFLEX’ 1. MOLDED CLOSED CELL ELASTOMERIC FOAM, ‘ARMAFLEX’, COMPLYING WITH ASTM C 534; TYPE II; FLEXIBLE, CELLULAR ELASTOMERIC, SHEETS. 2. THERMAL CONDUCTIVITY, "K" VALUE OF 0.27 AT 75 DEGREES F MEAN TEMPERATURE. 3. MAXIMUM/MINIMUM SERVICE TEMPERATURE: 220 / -70 DEGREES F. 4. MAXIMUM WATER VAPOR PERMEABILITY OF 0.08 TESTED IN ACCORDANCE WITH ASTM E 96 PROCEDURE A. 5. DENSITY OF NOT LESS THAN 5 LB. PER CU. FT. 6. MAXIMUM FLAME SPREAD/SMOKE DEVELOPMENT: 25/50. 7. INSULATION SHALL BE AP ARMAFLEX AS MANUFACTURED BY ARMACELL OR EQUAL BY RUBATEX. DUCTWORK INSULATION SPECIFICATIONS 1.ELASTOMERIC PAINT COATING: WHITE, WATER-BASED LATEX ENAMEL, WB ARMAFLEX FINISH OR EQUAL BY RUBATEX. JACKETING DUCTWORK INSULATION AND JACKET MATERIAL DUCTWORK DESCRIPTION INSULATION MATERIAL JACKET MATERIALCONDUCTIVITY MEAN RATING TEMPERATURE TYPE THICKNESS (INCHES) INTERIOR, EXPOSED APPLICATIONS (NON PROCESS AREAS) HEATING / COOLING SUPPLY DUCTS 0.27 AT 75 °F D 2 ELASTOMERIC PAINT COATING RETURN DUCTS IN CONDITIONED SPACE WITHIN 10FT OF SUPPLY UNIT OR EXTERIOR OPENING 0.27 AT 75 °F D 2 ELASTOMERIC PAINT COATING NOTES: I. THERMAL CONDUCTIVITY UNITS: BTU IN / (HR FT2 °F). II. ALL INSULATION THICKNESS MUST MEET THE MINIMUM ACCEPTABLE THERMAL CONDUCTIVITY AS STATED IN THE LATEST EDITION ASHRAE 90.1. R-VALUES SHALL MEET OR EXCEED ASHRAE STANDARDS ALSO. III. UNCONDITIONED SPACES INCLUDE CRAWL SPACES AND ATTICS. IV. COOLING DUCTS ARE THOSE DESIGNED TO CONVEY MECHANICALLY COOLED AIR OR RETURN DUCTS IN SUCH SYSTEMS. V. HEATING DUCTS ARE THOSE DESIGNED TO CONVEY MECHANICALLY HEATED AIR OR RETURN DUCTS IN SUCH SYSTEMS. VI. INTERIOR, EXPOSED APPLICATIONS (NON PROCESS AREAS) INCLUDE INTERSTITIAL SPACES. DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET NUMBER THE INFORMATION CONTAINED ON THIS AND ANY RELATED DOCUMENT SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THE CONVEYANCE OF INFORMATION FOR THE STATED CLIENT AND PROJECT WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER. ANY INFORMATION TRANSFERRED OR UTILIZED IN AUTOCAD .DWG FORMAT SHALL BE USED FOR REFERENCE ONLY WEBBER/SMITH Associates, Inc. 20 Wright Avenue Lititz, Pennsylvania 17543 Phone: 717.625.4140 Email:info@webbersmith.com SHEET TITLE: FOR DRAWING STATUS FINAL PROJECT NUMBER www.webbersmith.com SEAL M-001-1 BWI JSD 04/02/2024 MECHANICAL COVER SHEET 2350 Pullman WSS OCTA Aspire Bakeries 2350 Pullman Street Santa Ana, CA 92705 CA 5387 © 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved 2350 Pullman,LLC SHEET INDEX - MECHANICAL SHEET NUMBER SHEET NAME M-001-1 MECHANICAL COVER SHEET M-100-1 FLOOR PLAN - MECHANICAL M-601-1 MECHANICAL DETAILS AND SCHEDULES NO. DATE DESCRIPTION A 04/02/2024 ISSUED FOR PERMIT AND CONSTRUCTION REGISTERED PROFESSIONAL ENGINEER33478 JAMES S DEPEW STATE OF CALIFORNIAMECHANICAL 4/2/24 Deferred submittal to 101120904 (permit issued on 3/4/25) for Mechanical unit rooftop support Def Bldg permit #101124233 APPROVALS: PLNG - N. Tran BLDG - CSG DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET NUMBER THE INFORMATION CONTAINED ON THIS AND ANY RELATED DOCUMENT SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THE CONVEYANCE OF INFORMATION FOR THE STATED CLIENT AND PROJECT WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER. ANY INFORMATION TRANSFERRED OR UTILIZED IN AUTOCAD .DWG FORMAT SHALL BE USED FOR REFERENCE ONLY WEBBER/SMITH Associates, Inc. 20 Wright Avenue Lititz, Pennsylvania 17543 Phone: 717.625.4140 Email:info@webbersmith.com SHEET TITLE: FOR DRAWING STATUS FINAL PROJECT NUMBER www.webbersmith.com SEAL M-002-1 BWI JSD 11/04/2024 CODE COMPLIANCE DOCUMENTS 2350 Pullman WSS OCTA Aspire Bakeries 2350 Pullman Street Santa Ana, CA 92705 CA 5387 © 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved 2350 Pullman,LLC NO.DATE DESCRIPTION A 11/05/2024 BULLETIN #3 - PHASE 1 A 06- REGISTERED PROFESSIONAL ENGINEER33478 JAMES S DEPEW STATE OF CALIFORNIAMECHANICAL 11/5/24 1 2 3 H J N3 N1 N4 N5N6 N2 NA NAANBNCNDNENF DOCK ADDITION 131 TEMPORARY TENT 133 12"x10" TERMINATE THRU WALL 6" AND CAP FOR FUTURE EXTENSION SG-1 300 VD SG-1 300 VD SG-1 300 VD 12"x8"12"x6" EXTEND RETURN DUCT FULL SIZE TO 6" BELOW ROOF AND COVER OPEN END WITH 3/4"x3/4" GALV. SCREEN MESH RTU-1 T-STAT 14"x14" UP THRU ROOF TO RTU-1 RTU-1 TO BE BALANCED FOR FULL SYSTEM FLOW OF 400 CFM PER GRILLE. SYSTEM WILL BE REBALANCED TO 300 CFM PER GRILLE AFTER PHASE 2 EXISTING COOLER 102 EXISTING ELECTRICAL ROOM 101 1 2 3 4 H J N3 N1 N4 N5N6 N2 NA NAANBNCNDNENF RTU-1 DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET NUMBER THE INFORMATION CONTAINED ON THIS AND ANY RELATED DOCUMENT SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THE CONVEYANCE OF INFORMATION FOR THE STATED CLIENT AND PROJECT WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER. ANY INFORMATION TRANSFERRED OR UTILIZED IN AUTOCAD .DWG FORMAT SHALL BE USED FOR REFERENCE ONLY WEBBER/SMITH Associates, Inc. 20 Wright Avenue Lititz, Pennsylvania 17543 Phone: 717.625.4140 Email:info@webbersmith.com SHEET TITLE: FOR DRAWING STATUS FINAL PROJECT NUMBER www.webbersmith.com SEAL M-100-1 BWI JSD 04/02/2024 FLOOR PLAN - MECHANICAL 2350 Pullman WSS OCTA Aspire Bakeries 2350 Pullman Street Santa Ana, CA 92705 CA 5387 © 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved 2350 Pullman,LLC 1/8" = 1'-0"M-100-1 1 FLOOR PLAN - HVAC 1/8" = 1'-0"M-100-1 2 OVERALL ROOF PLAN - MECHANICAL NO. DATE DESCRIPTION A 04/02/2024 ISSUED FOR PERMIT AND CONSTRUCTION 1 2 EXISTING FACILITY KEY PLAN REFERENCE NORTH TRUE NORTH REGISTERED PROFESSIONAL ENGINEER33478 JAMES S DEPEW STATE OF CALIFORNIAMECHANICAL 4/2/24 PREFABRICATED INSULATED ROOF CURB PROVIDE WELL LINER OR DUCT CONNECTION WHERE REQUIRED. FASTEN TO METAL CURB AND STRUCTURAL FRAMING GALVANIZED SUPPORT ANGLE - SEE STRUCTURAL DRAWINGS METAL DECK ROOF MEMBRANE URETHANE BASED SEALANT BATTEN STRIP SCREWED TO CURB PER ROOFING MANUFACTURER REQUIREMENTS MEMBRANE FLASHING 22 GA. GALVANIZED TERMINATION STRIP SCREWED TO CURB PER ROOFING MANUFACTURER REQUIREMENTS COUNTERFLASHING URETHANE BASED SEALANT TREATED WOOD BLOCKING 1' - 3 " M I N . EQUIPMENT BASE URETHANE BASED SEALANT SHALL BE CONTINUOUS ON TOP OF CURB RESTRAINT CLIP AND EQUIPMENT BASE SCREWED TO CURB PER EQUIPMENT MANUFACTURER REQUIREMENTS GALVANIZED RESTRAINT CLIP DISCHARGE TO ROOF CLEANOUT PLUG (HAND TIGHTENED ONLY) DIA.(AS SIZED ON PLANS) COPPER PIPE - CVPC ALLOWED WHEN SUPPORTED TO WITHSTAND LOAD OF 250 LB. DRAIN CONNECTION FULL SIZE OF UNIT CONNECTION DRAIN PAN SEAL WATER TIGHT ST A T I C P R E S S U R E ( I N . ) MI N L E G = X / 2 + 1 " X = F A N T O T A L OR INDIRECT WASTE RECEPTOR INSULATE PER SPECIFICATIONS DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHEET NUMBER THE INFORMATION CONTAINED ON THIS AND ANY RELATED DOCUMENT SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THE CONVEYANCE OF INFORMATION FOR THE STATED CLIENT AND PROJECT WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER. ANY INFORMATION TRANSFERRED OR UTILIZED IN AUTOCAD .DWG FORMAT SHALL BE USED FOR REFERENCE ONLY WEBBER/SMITH Associates, Inc. 20 Wright Avenue Lititz, Pennsylvania 17543 Phone: 717.625.4140 Email:info@webbersmith.com SHEET TITLE: FOR DRAWING STATUS FINAL PROJECT NUMBER www.webbersmith.com SEAL M-601-1 BWI JSD 04/02/2024 MECHANICAL DETAILS AND SCHEDULES 2350 Pullman WSS OCTA Aspire Bakeries 2350 Pullman Street Santa Ana, CA 92705 CA 5387 © 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved 2350 Pullman,LLC 237413 - Packaged Rooftop Heat Pump Unit Schedule Mark Service Supply Fan Cooling Coil Heating Operating Weight (lbs.) Electrical Data Disconnect Requirement Electrical Data Basis of Design Notes Air Flow (CFM) HP E.S.P. (in.wg.) Entering (°F)Leaving (°F)Capacity (MBH)Ambient Dry Bulb Temp (°F) Output (MBH) Entering Air Temp (°F) Leaving Air Temp (°F)M.C.A.Voltage Phase Frequency (Hz)Smoke Detector Manufacturer ModelDesign Supply Air Flow Min. Outside Air Flow Dry Bulb Wet Bulb Dry Bulb Wet Bulb Sensible Total RTU-1 Dock 1,200 320 1.50 1.00 76.5 61.9 50.6 50.5 31.4 35.4 85 29.4 60.8 83.4 1000 10.0 480 3 60 By Electrical No Trane WHC036H4R0B**H1B1A1 Provide Economizer 233713 - Supply Grille Schedule Mark Description Material / Finish Inlet Size (In.)Front Blade Spacing Rear Blade Spacing Border Type Basis of Design Basis of Design CommentsWidthHeightManufacturerModel SG-1 Adjustable Supply Grille with Double Deflection Steel - Titus - 26 White 10"10"1"1"Surface Mount Titus 300RS NO SCALEM-601-1 A TYPICAL ROOF CURB NO SCALEM-601-1 B CONDENSATE TRAP DETAIL (PACKAGED ROOFTOP UNITS ONLY) NO.DATE DESCRIPTION A 04/02/2024 ISSUED FOR PERMIT AND CONSTRUCTION B 11/05/2024 BULLETIN #3 - PHASE 1 B 06- REGISTERED PROFESSIONAL ENGINEER33478 JAMES S DEPEW STATE OF CALIFORNIAMECHANICAL 11/5/24 Trane Precedent Packaged Rooftop Unit Overview - WHK036A4S00**K0D000010000000000000000000 Application Unit Size Supply Fan External Dimensions (in.)Operating Weight Elevation Heat Pump / Electric Heat 3 Ton Airflow Total Static Pressure Height Width Length 901.0 lb 0.00 ft 1200. cfm 1.060 in H2O 4.24 ft 4.44 ft 7.34 ft Unit Features Unit Efficiency High Efficiency Refrigerant R-454B Refrigerant EER @ AHRI 13.50 Number SEER @ AHRI 16.80 Number EER2 @ AHRI 12.80 Number SEER2 @ AHRI 16.20 Number Hinged Service Access/Filters Standard Access Panels with 2- in MERV 13 Fresh Air Selection Downflow Low Leak Economizer DB with BR Unit Electrical Voltage/phase/hertz 460/60/3 MCA 13.00 A MOP 15.00 A Condenser Fan FLA 0.55 A Evaporator Fan FLA 4.60 A Compressor 1 RLA 5.60 A Compressor 2 RLA 0.00 A Compressor Power 2.24 kW System Power 2.97 kW Controls Unit Controls Symbio 700 Communications Option Advanced Controls and BACnet BAS Cooling Section Entering Dry Bulb 80.00 F Entering Wet Bulb 67.00 F Ambient Temp 95.00 F Leaving Coil Dry Bulb 56.92 F Leaving Coil Wet Bulb 56.84 F Leaving Unit Dry Bulb 58.97 F Leaving Unit Wet Bulb 57.64 F Saturated Discharge Temperature 110.17 F Saturated Suction Temperature 51.45 F Capacity Gross Total 36.66 MBh Gross Latent 7.72 MBh Gross Sensible 28.94 MBh Net Total 35.51 MBh Net Sensible 27.79 MBh Net Sensible Heat Ratio 78.00 % Fan Motor Heat 0.58 MBh Refrig Charge-Circuit 1 12.0 lb Heating Section Heat Pump Heat pump Heating Capacity 32.74 MBh Heat pump EAT 70.00 F Heat pump LAT 99.41 F Heat pump heating ambient temperature 47.00 F Heat pump heating temperature rise 29.41 F Heat pump heating ambient relative humid 70.00 % AHRI COP @ 47 F 3.80 Number AHRI COP @ 17 F 2.46 Number Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 1 of 7 Fan Section Indoor Fan Data Airflow Application Downflow Design ESP 1.000 in H2O Component SP 0.060 in H2O Heat SP 0.000 in H2O Total SP 1.060 in H2O Indoor Fan Drive Type Direct Indoor Fan Quantity 1.00 Number Indoor Fan Type BC Plenum Indoor Fan Performance Airflow 1200. cfm Supply Motor Horsepower 3.000 hp Total Supply Motor Operating Power 0.560 hp Indoor RPM 963 rpm Outdoor Fan Data Outdoor Fan Drive Type Direct Outdoor Fan Quantity 1 Outdoor Fan Type Propeller Acoustics Sound Path 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Ducted Discharge 81 dB 76 dB 70. dB 66 dB 60. dB 57 dB 55 dB 56 dB Ducted Inlet 77 dB 68 dB 64 dB 52 dB 50. dB 48 dB 46 dB 45 dB Outdoor Noise 89 dB 78 dB 80. dB 79 dB 77 dB 72 dB 68 dB 62 dB Note:Ducted Discharge/Ducted Inlet prediction data conform to AHRI 260 Warranty Labor (first year)1st Yr Labor Whole Unit Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 2 of 7 Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 3 of 7 Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 4 of 7 Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 5 of 7 Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 6 of 7 Heatpump - Casing - Zinc coated, heavy gauge, galvanized steel. - Weather resistant pre-painted metal with galvanized substrate. - Meets ASTM B117, 672 hour salt spray test. - Removable single side maintenance access panels. - Lifting handles in maintenance access panels (can be removed and reinstalled by removing fasteners while providing a water and air tight seal). - Exposed vertical panels and top covers in the indoor air section insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. - Base pan shall have no penetrations within the perimeter of the curb other than the raised 1 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. - Base of the unit insulated with 1/8 inch, foil-faced, closed-cell insulation. - Unit base provisions for forklift and/or crane lifting on three sides of unit. Heatpump - Coils Evaporator and Condenser - Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin are standard. - Coils are leak tested at the factory to ensure integrity. - Evaporator coil and condenser coil are leak tested to 600 psig. - Assembled unit is leak tested to 465 psig. - Condenser coil is patent pending 1+1+1 hybrid coil, designed with slight gaps for cleaning ease. - Composite, dual-sloped, removable condensate drain pan is standard. Heatpump - Coil Guards - Provides condenser coil protection. Heatpump - Compressors - All units have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. - Suction gas-cooled motor with voltage utilization range of plus or minus 10 percent of unit nameplate voltage. - Internal overloads standard with scroll compressors. - Crankcase heaters are standard on all compressors. - All units have dual compressors. - Three stages of cooling available on 12.5 to 17.5 tons units and four stages of cooling available on 20 and 25 tons units. Heatpump - Filters - Standard throwaway filters - Optional 2 inch MERV 8 and MERV 13 filters Heatpump - Frostat - Utilized as a safety device. - Opens to prevent freezing temperatures on evaporator coil. - Temperature will need to rise to 50.0 F before closing. - Utilized in low airflow or high outside air applications (cooling only). Heatpump - Low Leak Economizer - This accessory meets the low leak requirements for ASHRAE 90.1, IECC, and CA Title 24 standards (4 cfm/ ft2@1" wg exterior air/return air). This option allows for 100% outdoor air supply from 0% to 100% modulating dampers and comes standard with barometric relief. It can be paired with powered exhaust for additional building pressure relief. This option can be paired with or without fault detection and diagnostics (FDD) to meet the current mandatory CA Title 24 requirements. The economizers come with four control options: dry bulb, reference enthalpy, comparative enthalpy, or differential dry bulb. Job Name: Arctic Cooling Systems - RFQ Prepared For: Unit Tag: HP-1 Quantity: 1 2025/02/13 18:49:34 Page 7 of 7