HomeMy WebLinkAbout2500 S Redhill Ave #100 and #110 - PlanCO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 Sec. 124(a) Portions of supply-air and return-air ducts ductwork conveying heated or cooled air located in one or more of the following spaces shall be insulated to a minimum installed level of R-8: 1. Outdoors, or 2. In a space between the roof and an insulated ceiling, or 3. In a space directly under a roof with fixed vents or openings to the outside or unconditioned spaces, or 4. In an unconditioned crawlspace, or 5. In other unconditioned spaces. Portions of supply-air ducts ductwork that are not in one of these spaces shall be insulated to a minimum installed level of R-4.2 (or any higher level required by CMC Section 605), or be enclosed in directly conditioned spaces. DUCT REVISIONS TO MATCH NEW ARCHITECTURAL REVISIONS IN THE IMPROVED SPACE. 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section contractor preparing documents for work that I have contracted to perform. EF EXHAUST FAN BG DI DO EDH DS AO AI AC BFC AFF BF BELOW GRADE DIGITAL OUTPUT DIGITAL INPUT ELECTRIC DUCT HEATER DISCONNECT SWITCH ANALOG INPUT ANALOG OUTPUT ABOVE FINISHED FLOOR ABOVE CEILING BELOW FLOOR BELOW FINISHED CEILING CONSTANT VOLUME FANCFPB DB DRY BULB EAT ENTERING AIR TEMPERATURE POWERED BOX EMS ENERGY MANAGEMENT SYSTEM VARIABLE AIR VOLUMEVAV SUPPLY AIR GENERAL CONTRACTOR RETURN AIR FAN POWERED BOX OPPOSED BLADE DAMPER FINS PER INCH MANUAL VOLUME DAMPER NEW(N) RA SA OBD FPB GC FPI MVD LEAVING AIR TEMPERATURELAT FEET PER MINUTEFPM NOT TO SCALENTS GAS UNIT HEATERGUH UNLESS NOTED OTHERWISEU.N.O. 4WAY CEILING DIFFUSER4WCD ELECTRIC UNIT HEATEREUH (E) EXISTING RELOCATED(R) (D) DEMOLISH & REMOVE DDC DIRECT DIGITAL CONTROL 3WAY CEILING DIFFUSER3WCD 2WAY CEILING DIFFUSER2WCD 1WAY CEILING DIFFUSER1WCD RETURN AIR REGISTERRAR CEILING DIFFUSERCD SIDEWALL SUPPLY REGISTERSWR MOVING SYSTEMS EXCEEDING 2,000 CFM PER SECTION 609.0 CMC PROVIDE SMOKE DETECTORS IN MAIN SUPPLY AIR DUCTS OF AIR (CMC SECTION 309) (MUST BE GFI PROTECTED IF ON ROOF) OF THE EQUIPMENT FOR SERVICE AND MAINTENANCE PURPOSES. 120-VOLT RECEPTACLE SHALL BE LOCATED WITHIN 25' Sec. 124(a) PROVIDE MERV-13 FILTERS ON ALL AIR HANDLING EQUIPMENT WITHIN THE SCOPE OF THESE PLANS. PLANCHECK REVISIONS: · ALL M-SHEETS: REVISED TITLE BLOCK TO INCLUDE SUITE NUMBERS. · ALL M-SHEETS: REVISED CODE REFERENCES TO 2022 FROM 2019. · TITLEBLOCK REVISIONS CLOUDED. 2022 CODE REFERENCES ARE NOT CLOUDED BY CHANGED GLOBALLY. Eric Maxwell Digitally signed by Eric Maxwell Date: 2023.01.30 12:37:18 -08'00' 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section contractor preparing documents for work that I have contracted to perform. FLEXIBLE AIR DUCT SHALL CONFORM TO U.L. 181, SHALL NOT BE MORE THAN 5 FEET LONG, AND SHALL NOT BE USED IN LIEU OF ELBOWS OR FITTINGS, EXCEPT AT A TERMINAL DEVICE. CMC 603.4.1, 603.5. 1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS. 1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK ON 8' CENTERS WITH 1 1/2" x 1 1/2" x 1/8" ANGLES ON CENTER LINE BETWEEN. 1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS WITH CROSS BREAK. INSIDE LONGITUDINAL STANDING SEAMS WITH 1 1/8" x 1 1/8" x 1/8" ANGLES ON 2' CENTERS ON EXTERIOR. 1 1/2" STANDING SEAM ON 3' CENTERS. 55 THRU 6020 1 1/2" STANDING SEAM ON 3' CENTERS. 1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS WITH CROSS BREAK. INSIDE LONGITUDINAL STANDING SEAMS WITH 1 1/8" x 1 1/8" x 1/8" ANGLES ON 2' CENTERS ON EXTERIOR. ON CENTER LINE BETWEEN. 1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK ON 8' CENTERS WITH 1 1/2" x 1 1/2" x 1/8" ANGLES 1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS. 43 THRU 54 31 THRU 42 22 1" BAR SLIP, REINFORCED BAR SLIP, OR 1" POCKET LOCK, ON 5' CENTERS. 1" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK ON 10' CENTERS WITH 1" x 1" x 1/8" ANGLES ON CENTER LINE BETWEEN. INSIDE LONGITUDINAL STANDING SEAMS WITH 1" x 1" x 1/8" ANGLES ON 5' CENTERS. 1" STANDING SEAM ON 5' CENTERS. HEMMED "S" SLIP, 1" BAR SLIP, OR 1" POCKET LOCK ON 10' CENTERS WITH CROSS BREAK 1"STANDING SEAM ON 5' CENTERS. ON CENTER LINE BETWEEN. HEMMED "S" SLIP, 1" BAR SLIP, OR 1" POCKET LOCK ON 10' CENTERS WITH 1"x1" x 1/8" ANGLES HEMMED "S" SLIP, 1" BAR SLIP, OR 1" POCKET LOCK ON 5' CENTERS. 19 THRU 30 24 DRIVE SLIP, PLAIN "S" SLIP, OR 1" POCKET LOCK13 THRU 18 GALVANIZED STEEL DUCT GAGE, PER SMACNA 006-2006 HVAC DUCT CONST. STANDARDS UP TO 2" W.C. U.S. STEEL STD. (GAGE) UP THRU 12 (INCHES) 26 DUCT DIMEN. DRIVE SLIP, PLAIN "S" SLIP, OR 1" POCKET LOCK MINIMUM METAL GAUGES PERMISSIBLE GIRTH JOINTS AND LOGITUDINAL SEAMS MAXIMUM 2 -INCH W.G. STATIC NEGATIVESTATIC POSITIVE MAXIMUM 10 -INCH W.G. 0.024 (24) INCH (GAGE) 0.036 (20) 0.030 (22) 0.047 (18) 0.058 (16) 0.024 (24) INCH (GAGE) 0.047 (18) 0.036 (20) 0.030 (22) 0.024 (24) 0.019 (26) 0.016 (28) 0.070 (14)0.058 (16) INCH (GAGE) INCH (GAGE) 0.019 (26) 0.024 (24) 0.030 (22) 0.036 (20) 0.047 (18) 0.019 (26) 0.047 (18) 0.024 (24) 0.036 (20) 0.047 (18) 0.058 (16) 0.030 (22) 0.036 (20) 0.024 (24) LOGITUDINAL SEAM SPIRAL SEAM SPIRAL SEAM LOGITUDINAL SEAM STATIC POSITIVE DUCT DIAMETER (INCHES) 0.024 (24) 0.036 (20) 0.030 (22) 0.019 (26) 0.016 (28) 0.016 (28) INCH (GAGE) 0.047 (18) 27 THROUGH 36 61 THROUGH 84 51 THROUGH 60 37 THROUGH 50 15 THROUGH 26 9 THROUGH 14 3 THROUGH 8 SPIRAL SEAM 0.058 (16) 0.047 (18) 0.036 (20) 0.030 (22) 0.024 (24) 0.019 (26) 0.016 (28) MAXIMUM 2 -INCH W.G. LOGITUDINAL SEAM INCH (GAGE) GALVANIZED STEEL DUCT GAGE, PER 602.1 C.M.C., SMACNA 006-2006 HVAC DUCT CONST. STANDARDS a. All appliances designed to be in a fixed position shall be securely fastened in place in accordance with the manufactures installation instructions. Supports for appliances shall be designed and constructed to resist horizontal and vertical loads within the stress limitations of the CBC. [CMC 303.4] b. All materials exposed within ducts and plenums including any above ceiling return air plenum shall be noncombustible or shall have a flame spread index not to exceed twenty-five (25) and a smoke developed index not to exceed then fifty (50) when tested as a composite product in accordance with ASTM E 84 OR UL 723 and shall comply with all requirements of the 2022 CMC Section 602.2. c. Installation of ducts shall be in accordance with Section 603.0 of the 2022: 1. All ductwork for heating and cooling system or evaporative cooling system shall be conducted through duct systems constructed of metal as set forth in the SMACNA HVAC Duct Construction Standard âfi Metal and Flexible. Factory made air ducts shall be approved for the use intended or shall comply with the 2022 CMC referenced standards Chapter 17. 2. Joints and seems for duct systems shall comply with SMACNA HVAC Duct Construction Standard âfi Metal and Flexible. Joints of ducts systems shall be made substantially airtight by means of tapes, mastics, gasketing, or other Crimp joints for round ducts shall have a contact lap of not less than 1-1/2" and shall be mechanically fastened by means of not less than 3 sheet-metals screws equally spaced around the joint, or an equivalent fastening method. 3. Ducts shall be supported at each change of direction and in accordance with SMACNA HVAC Duct Construction Standard âfi Metal and Flexible. d. Ducts and plenums shall comply with Section 120.4 of the 2022 California Building Energy Efficiency Standards. Provide the following notes on the plans to demonstrate compliance: Portions of supply-air and return-air ducts conveying heated or cooled air located in one or more of the following spaces shall be insulated to a minimum installed level of R-8: a. Outdoors; or b. In a space between the roof and an insulated ceiling; or c. In a space directly under a roof with fixed vents or openings to the outside or unconditioned spaces; or d. In an unconditioned crawlspace; or e. In other unconditioned spaces. 1. Portions of supply-air ducts that are not in one of these spaces, including ducts buried in concrete slab, shall be insulated to a minimum installed level of R-4.2 (or any higher level required by CMC Section 604.1) or be enclosed in directly conditioned space. 2. All factory-fabricated duct systems shall comply with UL 181 for ducts and closure systems, including collars, connections, and splices, and be labeled as complying with UL 181. Environmental air duct exhaust shall terminate not less than 3 ft from a property line, 10 ft from a forced air inlet, and 3 ft from openings into the building. Environmental exhaust ducts shall not discharge onto a public walkway. 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section contractor preparing documents for work that I have contracted to perform. 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 S1 CFM NECK S2 CFM NECK S3 CFM NECK R2 - NECK R1 - NECK R3 - NECK WAITING 100 STAFF BREAK 144 OFFICE 114 OFFICE 157 CONSULT 151 STORAGE 150A OFFICE 152 OFFICE 156 TELEHEALTH 154 TELEHEALTH 153 OPEN OFFICE 150 PANTRY 144A PHONE 143 CONSULT 147 CONSULT 148 CONSULT 149 HALLWAY 160 OFFICE 104 OFFICE 105 CHECK OUT 102 COPY/PRINT 103 CONFERENCE 106 OFFICE 107 OFFICE 108 STORAGE 109 IT/SERVER 110 113 OFFICE HALLWAY 161 155 OFFICE STORAGE 111 OFFICE 112 HALLWAY 162 OFFICE 115 TRAINING 116 OFFICE 129 OFFICE 130 133 OFFICE OFFICE 132 OFFICE 135 OFFICE 134 OFFICE 136 OFFICE 137 HALLWAY 159 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 142 HALLWAY 158 UNISEX RR 100A UNISEX RR 146 UNISEX RR 145 RECEPTION 101 OFFICE 117 OFFICE 118 HALLWAY 164 HALLWAY 163 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 122 OFFICE 123 OFFICE 124 OFFICE 125 OFFICE 126 OFFICE 127 OFFICE 128 OFFICE 131 (E) 12"Ø 14"Ø 14" Ø 14"Ø 10"Ø 10"Ø 10"Ø 12 " Ø 8"Ø 8"Ø 14"Ø 14"Ø 10"Ø 10"Ø 16"Ø 14"Ø 14"Ø 10"Ø 10"Ø 8"Ø 6"Ø 10"Ø 10"Ø 10"Ø 10"Ø 10"Ø 6"Ø 14"Ø 8"Ø 8"Ø 8"Ø 8"Ø 12"Ø 12"Ø 10"Ø 14"Ø 16"Ø 8"Ø 8"Ø 8"Ø 6"Ø 12"Ø 14"Ø 14"Ø 8"Ø8"Ø 8"Ø 8"Ø 10 " Ø 10 " Ø 12 " Ø 10"Ø 10"Ø 12"Ø 8"Ø8"Ø 8"Ø 8"Ø 8"Ø 8"Ø 8"Ø 10"Ø 10"Ø 6"Ø 10 " Ø 8"Ø 6"Ø 10"Ø8"Ø 8" Ø 8"Ø 8"Ø 8"Ø 12 " Ø 12 " Ø 8"Ø 10"Ø 16" DIAMETER RETURN DUCT TURNED TOWARD WALL WITH MESH CAP. 14"Ø14"Ø 10"Ø 10"Ø 12 " Ø 6"Ø S2 30 6 S1 400 10 S1 400 10 E 70 8 uc 1" uc 1" uc 1 " uc 1 " S1 350 10 S1 350 10 R 250 10 S1 350 10 S1 350 10 R 250 10 10"Ø 10"Ø10"Ø 10"Ø 10"Ø 10"Ø 14 " Ø 14 " Ø 12X10 SWR EF 1 EF 2 EF 3 4"Ø 4"Ø 4"Ø 7"Ø 8"Ø NEW SIDE-WALL EXHAUST EYEBROW AT EXTERIOR WALL, MIN. 10'-0" FROM ANY BUILDING OPENING OR FRESH AIR INTAKE. S1 90 6 S1 400 10 S1 400 10 S1 180 8 S1 400 10 S1 180 8 S1 100 8 (R) (R) (R) (R) (R) 8"Ø 8"Ø S2 60 6 S2 175 8 S2 175 8 (E) 8"Ø 6"Ø 6"Ø6"Ø S2 80 6 S2 80 6 (E) 60 6 6"Ø 6"Ø 6"Ø6"Ø 6"Ø R 145 8 R 90 8 S2 70 6 S2 70 6 E 480 12 R 360 10 (E) (E) 8" Ø 8"Ø (E)(E) uc 1" (E) (E) (E) (E) (E)(E) (R) (E) (R) (E) (E)6"Ø 6"Ø S2 60 6 E 110 8 E 60 8 S2 85 6 E 60 8 E 75 66"Ø 6"Ø 6"Ø6"Ø (R) (E) (E) E 75 6 S2 180 8 E 120 12 8"Ø 8"Ø 8"Ø N.I.C. N.I.C. N.I.C. E 175 10 S2 175 8 R 300 10 8"Ø (N) (N) (E) N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C.N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C.N.I.C.N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. N.I.C. 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section contractor preparing documents for work that I have contracted to perform. FRESH AIR NOTE: THE BUILDING IS SERVED BY A CENTRALIZED AIR HANDLING SYSTEM THAT INCLUDES A CO2 MONITORING SYSTEM IN THE AIR-STREAM THAT MODULATES THE FRESH AIR TO MAINTAIN 800 P.P.M. OR LESS OF CO2 IN THE CONDITIONED AIR STREAM. SYMBOL LOCATION SERVING CFM S.P. RPM AMPSWATTS VOLTAGE WEIGHT (lbs) REMARKS"MANUFACTURER" MODEL No. 975 70 0.1 78.8 3115v 1 ph. W/ PROVIDE WITH BACK-DRAFT DAMPER AND WALL SWITCH. "BROAN" 671CLG-MTD ALL GENDER RESTROOMS EF2EF1 EF3 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S EL E C T R I C A L C O V E R S H E E T E-1 SYMBOLS LIST NOTES ABBREVIATIONS FIRE ALARM & LIFE SAFETY FIXTURE SUPPORT DETAIL DEMOLITION NOTES TYPICAL WALL OUTLET SPACING DEVICE TYPE INFORMATION 2022 TITLE 24 COMPLIANT Lighting Controls A. Private offices less than 250sq.ft. - Provide Greengate Controls: Room Controller RC3D (120-277V), Five button Wall Station (Half Lights, Full Lights, Raise, Lower All Off) RC5-TSB-OS2-W, Ceiling Mount Microset Dual Tech OAC-DT-1000 + OCC-RJ45, 20A Receptacle Switchpack SPRC-R-20-120. At exterior offices with more than 24sq.ft. and more than 120W lighting load, provide DSRC-FMOIR + DSCM-MT photo-sensor mounting bracket. B. Private offices greater than 250sq.ft. - Provide Greengate Controls: Room Controller RC3D (120-277V), Five button Wall Station (Half Lights, Full Lights, Raise, Lower All Off) RC5-TSB-OS2-W, Ceiling Mount Microset Dual Tech OAC-DT-1000 + OCC-RJ45 (provide quantity of units indicated on plans), 20A Receptacle Switchpack SPRC-R-20-120. At exterior offices with more than 24sq.ft. and more than 120W lighting load, provide DSRC-FMOIR + DSCM-MT photo-sensor mounting bracket. C. Open area - Provide Greengate Controls: Room Controller RC3DE (120-277V), Five button Wall Station (Half Lights, Full Lights, Raise, Lower All Off) RC5-TSB-OS2-W, Ceiling Mount Microset Dual Tech OAC-DT-2000 + OCC-RJ45 (provide quantity of units indicated on plans), 20A Receptacle Switchpack SPRC-R-20-120. Primary and secondary daylight zones shall be controlled via photosensor. Provide DSRC-FMOIR + DSCM-MT photosensor mounting bracket. D. Switches - specification grade 120V/277V Leviton Decora 5691W - one way. Leviton Decora 5693W - three way. Power Devices A. Provide receptacles as follows: - 120V / 15 Amps. Leviton # 16252-W - 120V / 20 Amps. Leviton # 16352-W - 120V/ 20 Amps. Isolated ground type Leviton # 16362-IG-W - 120V/ 20 Amps. G.F.C.I. Leviton # 8899W B. Poke-thru devices as follows: - (1) Duplex + (2) tel./data Wiremold RC-3 - (1) Duplex + (4) tel./data Wiremold RC-7 - (1) Quad + (4) tel./data Wiremold RC4 series - Surface mounted duplex Wiremold 525 Series - Flush mounted power feed Wiremold RC9AM2TC - Flush mounted tel./data feed Wiremold RC9AM2TC - Surface mounted power feed Wiremold RC9AFFGY - Surface mounted tel./data feed Wiremold RC9AFFGY Notes: Provide conduit connector at the adapter assembly plates in order to maintain fire classification. All floor devices must meet "scrub water test". Coordinate color/finish with architect prior to ordering. Confirm in field exact device color to match existing building standard prior to ordering 2019 TITLE 24 additional requirements: Provide plenum rated RJ45 from room controller to all Greengate devices. Provide 1/2"C., 2#10 from room controller to each lighting zone indicated on plans. Provide 1/2"C.O. from all wallstations to 6" above accessible ceiling space. Provide sensor controlled receptacle within 6'-0" of all newly installed receptacles. Provide NEC required permanent marked devices when controlled via occupancy sensors: Half controlled duplex Legrand 26352CHW (remove midpoint wiring connector), full controlled receptacle Legrand 26352CDW PROVIDE ALTERNATE FOR 2019 TITLE 24 CONTROLS BY WATTSTOPPER. FIXTURE SCHEDULE NOTES F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-1 Electrical Cover Sheet.dwg, 3/15/2023 11:22:05 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 EL E C T R I C A L S P E C I F I C A T I O N S P A R T 1 o f 2 E-2 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 12 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-2 Electrical Specifications Part 1 of 2.dwg, 3/15/2023 11:22:20 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 EL E C T R I C A L S P E C I F I C A T I O N S P A R T 2 o f 2 E-3 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-3 Electrical Specifications Part 2 of 2.dwg, 3/15/2023 11:22:35 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S TI T L E 2 4 E N E R G Y C A L C U L A T I O N S E-4.1 F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-4 Title 24 Energy Calculations.dwg, 3/15/2023 11:20:30 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S TI T L E 2 4 E N E R G Y C A L C U L A T I O N S E-4.2 · · · · · · · F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-4 Title 24 Energy Calculations.dwg, 3/15/2023 5:27:01 PM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 J J J J J J J J J J J JJ J J J J J CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150A OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 EM E R G E N C Y F O O T C A N D L E C A L C U L A T I O N S E-5.1EMERGENCY FOOTCANDLE CALCULATIONS N C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S 1 Statistics Description Symbol Avg Max Min Max/Min Avg/Min 100A 7.2 fc 10.6 fc 2.2 fc 4.8:1 3.3:1 116 2.8 fc 5.0 fc 1.1 fc 4.5:1 2.5:1 141 3.4 fc 5.4 fc 1.3 fc 4.2:1 2.6:1 144 5.5 fc 10.2 fc 1.6 fc 6.4:1 3.4:1 145 7.4 fc 10.9 fc 2.4 fc 4.5:1 3.1:1 146 7.0 fc 10.0 fc 3.6 fc 2.8:1 1.9:1 150 3.8 fc 9.4 fc 1.2 fc 7.8:1 3.2:1 Corridor 4.2 fc 12.8 fc 1.1 fc 11.6:1 3.8:1 Schedule Symbol Label Quantity Manufacturer Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage F1 25 Lithonia Lighting 2BLT2 40L ADP LP835 BLT 2X2, 4000 Nominal Lumens, Curved Linear Prismatic lens, 3500K CCT 1 2BLT2_40L_ADP_LP83 5.ies 4040.879 0.28 31.1 F2 2 Lithonia Lighting 2BLT4 40L ADP LP835 BLT 2X4, 4000 Nominal Lumens, Curved Linear Prismatic lens, 3500K CCT 1 2BLT4_40L_ADP_LP83 5.ies 3999.88 0.28 30.99 F4 6 CSL Lighting LPF-35 1 2570 0.28 35 F5 5 Wac Lighting OLS-DI-LED-2-S-4'-D500L-U1000L 2C-DIM10-MVOLT-35K-SI-OCGS 1 4470 0.48 50.8 4.7 5.0 4.6 5.6 5.8 5.2 5.8 6.1 5.5 5.6 5.9 5.3 4.8 5.1 4.7 3.9 4.1 4.0 3.4 3.6 3.4 1.6 1.9 2.5 3.3 4.2 4.8 4.8 4.2 3.3 2.5 2.0 2.2 2.1 2.0 1.9 1.2 1.5 1.7 1.1 2.9 3.0 2.9 1.7 2.1 2.8 3.8 4.8 5.5 5.5 4.7 3.7 2.7 2.0 2.0 2.6 2.5 2.4 1.4 1.8 2.2 2.1 2.7 2.7 2.7 2.0 2.1 2.7 3.6 4.5 5.2 5.2 4.5 3.5 2.6 1.9 1.5 3.1 3.3 3.1 1.3 2.3 3.0 3.5 3.7 3.2 2.6 2.1 1.7 1.6 2.0 2.7 2.6 2.4 3.0 3.5 3.9 4.0 4.0 4.6 4.6 4.0 3.2 2.4 1.8 1.5 2.3 2.9 2.9 2.7 3.3 4.2 4.9 4.8 4.6 5.2 5.1 4.4 3.3 2.4 1.8 1.4 1.8 3.5 3.5 3.2 3.3 4.6 5.4 5.3 4.6 5.2 5.1 4.1 3.0 2.3 1.7 1.3 1.1 4.4 4.4 3.8 4.4 5.3 5.2 4.1 4.6 4.6 5.1 5.3 3.9 4.6 4.5 5.6 5.8 4.9 3.2 3.7 3.7 8.1 9.0 8.5 6.3 3.5 2.1 3.4 6.1 8.4 9.5 10.8 11.0 10.4 9.3 5.5 5.6 4.7 2.6 3.0 2.9 9.0 8.3 8.7 7.4 4.2 2.8 4.0 7.0 8.8 9.1 12.1 11.0 9.0 4.7 4.8 4.1 2.3 2.5 2.5 8.3 8.9 8.7 6.9 4.6 3.4 4.4 6.6 8.5 9.5 11.0 11.3 10.6 9.3 3.8 3.9 3.4 2.1 2.3 2.3 6.2 7.2 7.1 6.5 5.7 5.2 5.6 6.3 6.8 7.1 7.6 7.8 7.8 7.4 3.1 3.2 2.9 2.2 2.3 2.3 5.0 6.1 6.9 7.3 7.7 7.9 7.4 6.3 5.0 4.1 4.1 5.0 5.9 6.0 2.7 2.7 2.5 2.5 2.7 2.6 5.7 7.2 8.5 9.5 9.9 8.5 8.6 6.7 4.0 2.5 3.1 4.9 6.6 7.0 2.5 2.5 2.4 2.9 3.3 3.2 8.0 9.2 10.7 11.5 11.1 8.8 8.7 6.6 3.8 2.5 4.0 6.7 8.7 9.0 2.6 2.6 2.5 3.6 4.1 4.1 9.0 8.5 10.2 11.2 10.3 8.9 7.4 5.3 3.0 2.6 4.6 7.8 8.8 8.6 2.9 2.9 2.8 4.3 5.1 5.0 8.3 9.0 9.2 8.6 4.1 7.0 8.9 9.1 3.4 3.5 3.3 4.6 5.6 5.5 6.1 7.1 6.6 5.1 6.8 7.2 4.3 4.4 3.9 4.5 5.4 5.4 3.4 3.9 4.4 3.2 2.9 2.7 2.6 4.5 4.4 4.1 5.1 5.3 4.6 4.0 4.7 4.6 2.6 3.6 4.6 5.2 5.2 4.3 3.7 3.2 3.0 3.2 3.7 4.8 5.4 5.3 4.7 5.5 5.7 4.9 3.3 3.8 3.7 2.8 3.8 4.8 5.6 5.5 4.8 4.0 3.4 3.2 3.4 4.1 5.0 5.8 5.7 5.0 5.3 5.4 4.4 3.3 2.7 3.0 3.0 2.8 3.7 4.7 5.3 5.3 4.7 3.9 3.4 3.2 3.5 4.1 4.9 5.6 5.5 4.9 4.5 4.6 4.1 3.3 2.3 2.5 2.5 2.7 3.4 4.1 4.6 4.6 4.2 3.6 3.2 3.0 3.2 3.7 4.5 5.3 5.3 4.5 3.8 5.2 2.1 2.3 2.3 1.4 1.6 4.2 4.6 4.7 5.0 4.2 5.2 6.0 5.9 5.1 5.8 4.8 2.3 1.5 2.2 2.3 2.3 1.6 2.5 3.7 4.0 4.3 4.3 5.1 5.5 5.9 5.9 5.5 5.4 4.3 3.1 1.5 2.4 2.6 2.6 1.9 2.9 3.4 3.7 3.9 4.6 3.9 3.2 1.5 2.9 3.2 3.2 2.3 3.1 3.2 3.2 3.1 2.5 3.3 3.2 3.6 4.1 4.1 2.6 3.2 3.6 3.6 3.4 2.8 2.9 2.9 4.2 5.0 5.0 3.0 3.8 4.3 4.4 4.1 3.4 3.5 3.2 4.6 5.5 5.5 1.6 4.3 5.3 5.3 4.7 4.2 4.3 3.8 4.5 5.4 5.3 5.9 5.9 5.1 5.1 5.2 4.5 3.9 4.6 4.5 5.9 5.8 5.0 5.5 5.6 4.8 3.2 3.6 3.5 5.3 5.2 4.6 5.3 5.4 4.6 2.6 2.8 2.7 4.6 4.6 4.0 2.2 2.2 2.0 3.7 3.7 3.3 2.1 2.0 1.7 3.0 3.0 2.7 2.3 2.3 1.7 2.5 2.6 2.3 2.6 3.0 2.4 2.3 2.4 1.7 2.7 3.5 4.3 2.4 2.4 1.4 2.9 3.8 4.8 5.4 5.3 4.6 3.6 2.7 2.0 1.5 1.1 2.8 2.9 2.4 2.8 3.7 4.7 5.3 5.2 4.5 3.6 2.7 2.0 1.5 1.1 3.4 3.5 3.0 2.7 3.4 4.0 4.3 4.4 3.8 2.5 3.0 2.9 5.1 5.3 4.5 2.4 2.6 2.0 5.5 5.7 4.8 2.4 2.4 2.0 5.3 5.5 4.7 2.5 2.6 2.4 5.3 5.4 4.2 3.0 3.2 3.1 4.0 5.0 5.7 5.7 5.0 4.1 3.2 2.7 2.6 4.9 5.2 5.3 4.1 5.0 5.7 5.7 5.0 4.0 3.2 2.7 2.4 2.4 2.7 3.2 3.9 4.2 4.1 4.0 5.0 5.7 5.6 5.0 4.0 3.2 2.7 3.6 4.1 4.3 4.7 5.1 5.0 5.7 5.6 4.9 4.0 3.2 2.7 2.5 2.5 2.9 3.6 4.5 5.2 5.0 2.5 3.1 3.9 5.1 5.7 5.5 2.8 3.7 5.0 5.5 5.4 3.9 4.5 4.8 4.6 3.4 3.6 3.9 3.9 3.6 3.6 3.5 3.3 4.5 4.3 3.8 3.3 2.4 2.5 2.5 5.3 5.4 4.9 4.0 3.0 3.3 3.1 5.1 5.8 5.8 5.0 3.7 4.2 4.0 4.2 5.0 5.6 5.4 4.4 5.1 4.9 3.6 3.9 4.3 4.7 4.8 5.6 5.4 3.4 3.8 3.3 3.4 4.7 5.3 5.2 3.4 3.9 4.1 2.5 4.1 4.6 4.4 3.4 4.1 4.6 4.7 3.4 3.7 3.6 3.1 3.9 4.8 5.5 4.9 2.8 3.0 2.9 2.7 3.3 4.1 5.1 5.6 5.4 4.6 2.4 2.5 2.5 2.8 2.8 3.0 2.6 4.6 5.2 5.3 4.6 3.5 2.3 2.4 2.3 3.2 2.8 2.3 1.8 4.3 4.5 4.0 3.2 2.4 2.4 2.5 2.4 4.2 3.8 3.1 2.4 3.3 3.2 2.6 2.1 1.7 2.6 2.8 2.7 5.1 5.2 4.5 3.5 2.4 2.1 1.8 3.1 3.4 3.3 4.8 5.7 5.7 4.8 1.7 3.8 4.3 4.1 3.7 4.9 5.6 5.4 4.5 5.1 5.0 2.7 3.8 4.4 4.7 4.8 5.5 5.4 2.5 3.1 3.4 3.6 4.6 5.3 5.2 3.5 1.8 2.1 2.1 2.2 2.3 2.3 2.4 2.6 2.7 3.5 4.3 4.9 4.9 4.2 3.8 3.2 3.0 2.9 4.0 4.5 4.4 3.8 2.9 2.1 2.8 2.8 2.8 2.8 2.8 2.3 2.9 3.8 4.8 5.5 5.6 4.9 4.0 3.2 2.7 3.3 3.6 3.5 3.1 2.7 2.2 3.5 3.6 3.6 3.4 2.1 2.2 2.8 3.7 4.6 5.3 5.3 4.6 3.8 3.0 4.4 4.2 3.7 4.8 4.9 4.4 5.3 5.3 4.6 5.1 5.2 4.4 4.4 4.4 3.9 3.5 3.5 3.1 2.7 2.7 2.5 2.1 2.2 1.9 1.4 12.8 3.1 3.3 3.3 2.9 2.5 2.1 1.8 1.6 1.4 1.3 1.2 1.1 3.9 4.3 4.2 3.7 3.0 2.5 2.0 1.8 1.6 1.4 1.3 1.2 4.4 4.9 4.8 4.2 3.4 2.7 2.3 2.0 1.8 1.7 1.5 1.4 4.4 4.9 4.3 3.5 2.9 2.5 2.2 2.1 2.0 1.9 1.7 4.0 4.4 4.4 3.9 3.3 2.9 2.6 2.6 2.6 2.6 2.5 2.3 2.0 3.2 3.6 3.6 3.3 3.0 2.8 2.8 3.0 3.2 3.3 3.2 2.9 2.5 2.1 2.5 2.7 2.8 2.7 2.6 2.7 2.9 3.4 3.9 4.2 4.1 3.6 2.9 2.4 1.9 2.0 2.1 2.2 2.2 2.3 2.6 3.0 3.7 4.4 4.8 4.7 4.1 3.3 2.6 2.1 1.6 1.7 1.8 1.9 2.1 2.4 2.9 3.6 4.4 4.9 4.8 4.1 3.3 2.6 1.4 1.4 1.5 1.7 1.9 2.2 2.6 3.2 3.9 4.3 4.2 3.7 3.1 1.3 1.3 1.4 1.5 1.7 1.9 2.3 2.7 3.1 3.4 3.4 3.1 5.0 1.6 1.9 2.2 2.5 2.7 2.8 2.8 2.7 2.5 2.2 1.8 1.9 2.3 2.8 3.3 3.6 3.8 3.8 3.7 3.3 2.9 2.1 2.1 2.7 3.5 4.5 5.0 5.1 5.2 5.1 4.5 3.9 2.9 2.4 3.2 4.4 5.9 6.7 6.7 7.0 6.8 5.9 5.3 4.5 2.5 3.5 5.1 7.0 8.1 8.1 8.5 8.3 7.2 6.8 6.9 7.9 7.7 7.6 2.5 3.5 5.2 7.2 8.4 8.3 8.9 8.7 7.9 8.0 8.8 9.1 9.1 9.2 2.3 3.2 4.7 6.4 7.4 7.4 7.9 8.0 7.6 8.4 9.8 10.0 10.0 1.9 2.3 4.1 5.1 5.7 5.9 6.0 5.9 5.6 5.2 9.6 9.8 9.7 9.9 3.3 3.9 4.2 4.3 4.4 4.0 3.4 2.6 7.8 8.0 8.3 8.510.2 1.7 2.2 2.9 3.7 4.7 5.1 5.1 5.0 4.6 3.6 2.8 1.8 2.3 3.2 4.5 6.0 6.7 6.5 6.6 5.9 4.4 3.1 1.8 2.4 3.4 5.0 6.9 7.8 7.5 7.6 6.7 4.8 3.3 1.7 2.3 3.3 4.9 6.7 7.6 7.3 7.5 6.6 4.7 3.1 2.1 1.6 1.7 2.2 3.0 4.2 5.7 6.3 6.1 6.2 5.5 4.1 2.8 2.0 1.6 1.5 1.9 2.6 3.4 4.2 4.6 4.5 4.5 4.2 3.3 2.5 1.9 1.5 1.4 1.7 2.1 2.6 3.1 3.3 3.3 3.2 3.0 2.5 2.1 1.7 1.4 1.3 1.5 1.8 2.0 2.3 2.5 2.5 2.4 2.3 2.0 1.8 1.5 1.3 1.2 1.4 1.5 1.7 1.9 2.0 2.0 2.0 1.9 1.7 1.5 1.4 1.3 1.2 1.3 1.4 1.5 1.7 1.8 1.8 1.7 1.7 1.6 1.5 1.3 1.2 1.2 1.3 1.4 1.5 1.6 1.7 1.7 1.7 1.7 1.6 1.5 1.4 1.2 1.2 1.3 1.5 1.6 1.7 1.8 1.9 1.9 1.8 1.7 1.6 1.4 1.3 1.3 1.4 1.6 1.9 2.0 2.2 2.2 2.2 2.1 1.9 1.7 1.6 1.4 1.3 1.6 1.9 2.2 2.6 2.8 2.8 2.8 2.6 2.4 2.0 1.8 1.5 1.5 1.8 2.3 2.9 3.5 3.8 3.9 3.8 3.5 3.0 2.5 2.1 1.7 1.6 2.1 2.8 3.8 4.8 5.3 5.3 5.3 4.9 4.0 3.1 2.4 2.0 1.6 2.2 3.2 4.6 6.3 7.0 7.0 7.1 6.5 5.0 3.7 2.9 2.3 3.5 5.2 7.3 8.4 8.3 8.5 7.7 5.9 4.4 3.4 2.7 3.6 5.2 7.2 8.2 8.4 8.8 8.2 6.5 5.0 4.1 3.3 3.4 4.6 6.1 6.8 7.1 8.3 8.1 6.9 5.9 5.1 4.2 3.0 3.8 4.7 5.1 5.1 6.1 8.1 7.7 7.0 6.5 6.0 8.3 8.7 8.2 8.2 7.5 7.8 9.2 9.3 8.4 7.7 8.8 8.9 9.1 8.3 6.7 7.4 7.6 7.8 7.2 5.3 5.8 5.9 6.0 5.7 4.1 4.4 4.5 4.6 4.4 9.4 F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F1 @ 9.5' F2 @ 9.5' F2 @ 9.5' F5 @ 8' F5 @ 8' F5 @ 8'F5 @ 8' F5 @ 8' F4 @ 8' F4 @ 8'F4 @ 8' F4 @ 8' F4 @ 8' F4 @ 8' F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-5.1 Emergency Footcandle Calculations.dwg, 3/15/2023 11:22:51 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 J J J J J J J J J J J JJ J J J J J CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150A OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 EL E C T R I C A L L I G H T I N G P L A N E-5ELECTRICAL LIGHTING PLAN N C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S LIGHTING PLAN NOTES TESTING & ADJUSTING OF CONTROLS · · · · 1 Label Manufacturer Catalog Number Description Lamp WattageSymbol Fixture Type F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-5 Electrical Lighting Plan.dwg, 3/15/2023 4:53:30 PM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 R J J J J J J J J J J J JJ J J J J N N N N NN N N N N N N N N N N N N N N N N N N N N N N N N N N NN N GF I ( N ) TVN N N CR CR CR CR F.E.C. F. E . C . F.E.C. CR CR TVN N N F.E.C. J TV N N N GFI (N) CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150A OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 +60" (X2) +60" (X2) +60" EL E C T R I C A L P O W E R P L A N E-6ELECTRICAL POWER PLAN N C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S · · · · 1 POWER PLAN NOTES SINGLE LINE DIAGRAM SCALE: 1/8" = 1'-0" N.I.C. N.I.C. N.I.C. N.I.C.N.I.C. F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-6 Electrical Power Plan.dwg, 3/15/2023 5:32:02 PM Circuit corrected to A-27 M. Smith (19) 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S SCALE: "RC3" ROOM CONTROLLER WITH WALL STATION CONTROL NONE3B SCALE: "RC3" ROOM CONTROLLER WITH WALL SENSOR CONTROL NONE3A SCALE: "RC2" ROOM CONTROLLER WITH WALL STATION CONTROL NONE 2B SCALE: "RC2" ROOM CONTROLLER WITH WALL SENSOR CONTROL NONE 2A SCALE: "RC1" ROOM CONTROLLER WITH WALL STATION CONTROL NONE1B INPUT MODULE LMIO-101 SHALL BE PROVIDED WHERE SCOPE OF WORK IS MINIMUM 10,000 sqft. SCALE: "RC1" ROOM CONTROLLER WITH WALL SENSOR CONTROL NONE1A SCALE: "EL" ELCU 200 TYPICAL WIRING DIAGRAM NONE 1C INPUT MODULE LMIO-101 SHALL BE PROVIDED WHERE SCOPE OF WORK IS MINIMUM 10,000 sqft. INPUT MODULE LMIO-101 SHALL BE PROVIDED WHERE SCOPE OF WORK IS MINIMUM 10,000 sqft. INPUT MODULE LMIO-101 SHALL BE PROVIDED WHERE SCOPE OF WORK IS MINIMUM 10,000 sqft. INPUT MODULE LMIO-101 SHALL BE PROVIDED WHERE SCOPE OF WORK IS MINIMUM 10,000 sqft. INPUT MODULE LMIO-101 SHALL BE PROVIDED WHERE SCOPE OF WORK IS MINIMUM 10,000 sqft. LMLS 500 PHOTOSENSOR SHALL BE INSTALLED WHERE SO NOTED ON PLANS LMLS 500 PHOTOSENSOR SHALL BE INSTALLED WHERE SO NOTED ON PLANS LMLS 500 PHOTOSENSOR SHALL BE INSTALLED WHERE SO NOTED ON PLANS LMLS 500 PHOTOSENSOR SHALL BE INSTALLED WHERE SO NOTED ON PLANS LMLS 500 PHOTOSENSOR SHALL BE INSTALLED WHERE SO NOTED ON PLANS LMLS 500 PHOTOSENSOR SHALL BE INSTALLED WHERE SO NOTED ON PLANS TY P I C A L L I G H T I N G C O N T R O L D I A G R A M S E-7 F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-7 Lighting Control Details.dwg, 3/15/2023 11:23:05 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 C: \ _ R e v i t \ 6 0 7 4 _ A R C H _ j p o l l o c k 8 E 2 L 6 . r v t SDG22-6057-00 CO R T I C A S A N T A A N A 25 0 0 R E D H I L L A V E SA N T A A N A C A 9 2 7 0 5 CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT 1 2 / 0 9 / 2 0 2 2 3: 3 6 : 0 5 P M SAB CAD DA T E RE M A R K S JOB NO.: DRAWN BY.: PA/PM: SHEET El e c t r i c a l Me c h a n i c a l Pl u m b i n g 24 0 0 E K a t e l l a A v e . , S u i t e 8 1 5 An a h e i m C A 9 2 8 0 6 of f i c e fa x (7 1 4 ) 4 4 9 - 1 6 4 6 (7 1 4 ) 4 4 9 - 1 9 4 6 Co n s u l t i n g E n g i n e e r s - 20 2 3 - 0 1 - 2 7 IS S U E F O R P E R M I T SU I T E 1 0 0 1 20 2 3 - 0 2 - 0 3 PL A N C H E C K S U B M I T T A L 2 20 2 3 - 0 3 - 1 6 IS S U E F O R P L A N C H E C K C O R R E C T I O N S EL E C T R I C A L D E T A I L S E-8 3 TYPICAL TEL. BOARD GROUNDING BAR INSTALLATION DO NOT DISCONNECT 3 - PANELS NAMEPLATE2 DIST. PANEL CRPP1A1 DIST. PANEL CRPP1A1 PURPLE ORANGE NOT PAINTED RED YELLOW BLUE & WHITE GREEN & BLUE ORANGE & WHITE NOT PAINTED PVC-NOT PAINTED GENERAL NOTES: COLOR J-BOX PAINT GROUND CONDUITS 480V NORMAL 208/120V NORMAL SECURITY TELECOM FIRE ALARM BMS CONTROLS 208/120V UPS 480/277V UPS 277V NORMAL (LTG.) SERVICE GREEN WHITE GREEN BLUE BLUE & WHITE ORANGE & WHITE GREEN & BLUE YELLOW RED WHITE ORANGE CONDUIT TAPE COLOR LEGEND COLOR PURPLE BLUEWHITE BLACK BLACK WHITE WHITE WHITE WHITE WHITE YELLOW BLACK RED WHITE BLUE ORANGE ORANGE NAMEPLATE COLOR WHITE DARK PURPLE PANEL CRPP1A1 BRPP1A1-22,24,26 1 RACEWAY AND NAMEPLATE IDENTIFICATION TELEPHONE/DATA OUTLETS 4 TYPICAL FIRESTOP PENETRATION DETAILS5 F:\Projects\Santa Ana\Red Hill Ave\2500 Red Hill Ave\01\Suite 100 ( Cortica )\2500 Red Hill Ave., Cortica E-8 Electrical Details.dwg, 3/15/2023 11:23:18 AM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 N NOT TO SCALE 5 55 PROJECT SITE RED HILL AVE BARRA N CA PKWY 261 405 C 1 PL 1 P 1 X ALIGN ROOM NAME DOOR NUMBER ROOM NUMBER DETAIL REFERENCE SHEET NUMBER SHEET NUMBER DETAIL SECTION REFERENCE 0000 OFFICE X XX X XX 101 SHEET NUMBER SECTION REFERENCE KEYNOTE INDICATOR X XX XX-# REVISION CLOUD & DELTA NUMBER EQUIPMENT TAG SHEET NUMBER INTERIOR ELEVATION REFERENCE SHEET NUMBER EXT. ELEVATION REFERENCE FLOOR MATERIAL TYPE FLOOR NOTE WALL MATERIAL TYPE WALL NOTE MISC. MATERIAL TYPE TYPE NUMBER EXISTING DOOR WALL TAGX XX A B C D X XX XXX 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 3 9 P M K. BURGER CB / JG SDG22-6057-00 TI T L E S H E E T I0.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 ARCHITECT LOCATION MAP (For Tenant Improvement Permit Only) SHEET INDEX ISSUANCE 12 / 2 0 / 2 0 2 2 SHEET ISSUED ON DATE INDICATED, WITH MODIFICATIONS SHEET ISSUED ON DATE INDICATED, NO MODIFICATIONS ELECTRICAL E-1 ELECTRICAL COVER SHEET E-2 ELECTRICAL SPECIFICATIONS PART 1 OF 2 E-3 ELECTRICAL SPECIFICATIONS PART 2 OF 2 E-4.1 TITLE 24 ENERGY CALCULATIONS E-4.2 TITLE 24 ENERGY CALCULATIONS E-5 ELECTRICAL LIGHTING PLAN E-5.1 EMERGENCY FOOTCANDLE CALCULATIONS E-6 ELECTRICAL POWER PLAN E-7 TYPICAL LIGHTING CONTROL DIAGRAMS E-8 ELECTRICAL DETAILS ELECTRICAL SHEET COUNT: 10 MECHANICAL M-1 MECHANICAL NOTESHEET M-1.1 MECHANICAL NOTESHEET M-1.2 T-24 M-2 MECHANICAL PLANS, NOTES & SCHEDULES MECHANICAL SHEET COUNT: 4 PLUMBING P-1.0 PLUMBING NOTES, DETAILS, SPECS, & SCHED. P-2.0 PLUMBING PLANS PLUMBING SHEET COUNT: 2 ARCHITECTURAL I0.1 TITLE SHEET I0.2 GENERAL NOTES I0.3 ACCESSIBILITY DETAILS I0.4 SITE PLAN (For Reference Only) I0.5 OCCUPANCY AND EGRESS PLAN I0.6a CAL GREEN NOTES I0.6b CAL GREEN NOTES I1.1 DEMOLITION FLOOR PLAN I1.1a DEMOLITION CEILING PLAN I2.1 FLOOR PLAN I3.1 POWER & SIGNAL PLAN I4.1 REFLECTED CEILING PLAN I5.1 FINISH PLAN I6.1 ENLARGED RESTROOM PLAN AND ELEVATIONS I6.2 ENLARGED FLOOR PLAN AND ELEVATIONS I6.3 MILLWORK & GLAZING ELEVATIONS I7.1 DOOR SCHEDULE AND DETAILS I8.1 DETAILS I8.2 DETAILS I8.3 DETAILS ARCHITECTURAL SHEET COUNT: 20 CORTICA SANTA ANA SUITES 100 & 110 2500 RED HILL AVENUE SANTA ANA, CA 92705 PROJECT DESCRIPTION & SCOPE PROJECT DIRECTORY BUILDING OWNER TENANT DEFERRED SUBMITTALS GENERAL CONTRACTOR BUILDING & CODE INFORMATION PROJECT DESCRIPTION:THE SCOPE OF THIS PROJECT IS AN INTERIOR TENANT IMPROVEMENT PROJECT TO AN EXISTING OFFICE SUITE. SCOPE OF WORK TO INCLUDE NEW NON-LOAD BEARING / NON-RATED PARTITIONS, CEILINGS, AND FLOOR / WALL FINISHES, AND ASSOCIATED MECHANICAL, ELECTRICAL, AND PLUMBING. NEW DEMISING PARTITION TO CREATE SUITE 110. NO CHANGE IN USE. OCC. CLASSIFICATION:B - BUSINESS CHANGE IN USE: YES NO DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEERS OF RECORD WHO SHALL REVIEW AND PROVIDE NOTATION INDICATING DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE WITH THE BUILDING DESIGN. SUBMITTAL MATERIALS SHALL INCLUDE PLANS, DETAILS AND CALCULATIONS PREPARED AND SIGNED BY A STATE REGISTERED ENGINEER. CONTRACTOR SHALL SUBMIT ARCHITECT AND ENGINEER REVIEWED SUBMITTAL MATERIALS TO THE BUILDING OFFICIAL FOR REVIEW AND PERMIT APPROVAL. DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED PRIOR TO OBTAINING THE BUILDING OFFICIAL'S APPROVAL OF THE SUBMITTAL. 1. AUTOMATIC FIRE SPRINKLER SYSTEM. 2. FIRE ALARM SYSTEM. OFFICE (B) 13,407 S.F. TOTAL 13,407 S.F.SCOPE AREA(S): BUILDING DEPARTMENT: APPLICABLE BUILDING CODES: CITY OF SANTA ANA 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA FIRE CODE (WITH LOCAL AMENDMENTS) 2022 STATE OF CALIFORNIA ENERGY CODE 2022 STATE OF CALIFORNIA GREEN BUILDING CODE 2022 STATE OF CALIFORNIA TITLE 24 ACCESSIBILITY STANDARDS BUILDING TYPE:V-B NUMBER OF STORIES: YEAR BUILT: OCCUPANCY CLASS: SEPARATIONS: FIRE SPRINKLERS: FIRE ALARM: ACCESSOR'S PARCEL #: LEGAL DESCRIPTION: 2 1985 B CBC 602 CBC CHAPTER 3 CBC TABLE 508.4 430-221-18 P BK 236 PG 37 PAR 1 YES NO YES NO YES NO BLOCK/LOT:9 / POR 105 CONTRACTOR'S CONSULTANTS (DESIGN-BUILD) PRIMARY CONTACT: PH: EMAIL: ALTERNATE CONTACT: PH: EMAIL: COMPANY NAME MECHANICAL & PLUMBING ENGINEER ADDRESS LINE 1 ADDRESS LINE 2 CITY, STATE XXXXX (XXX) XXX-XXXX CONTACT (XXX) XXX-XXXX XXX@XXX.XXX (XXX) XXX-XXXX XXX@XXX.XXX PRIMARY CONTACT: PH: EMAIL: ALTERNATE CONTACT: PH: EMAIL: COMPANY NAME ELECTRICAL ENGINEER ADDRESS LINE 1 ADDRESS LINE 2 CITY, STATE XXXXX (XXX) XXX-XXXX CONTACT (XXX) XXX-XXXX XXX@XXX.XXX (XXX) XXX-XXXX XXX@XXX.XXX PRIMARY CONTACT: PH: EMAIL: ALTERNATE CONTACT: PH: EMAIL: MOONCREST PROPERTY COMPANY MOONCREST PROPERTY COMPANY PO BOX 719 CAMARILLO CA, 93011 BRIAN GIVEN (805) 482-2761 BGIVEN@MOONCRESTPC.COM - - - PRIMARY CONTACT: PH: EMAIL: ALTERNATE CONTACT: PH: EMAIL: CORTICA CORTICA 6160 CORNERSTONE COURT EAST SUITE 100 SAN DIEGO, CA 92121 HEATHER MOOR (540) 293-9609 hmoor@corticacare.com LISA POGGE (858) 216-8837 lpogge@corticacare.com PRIMARY CONTACT: PH: EMAIL: ALTERNATE CONTACT: PH: EMAIL: COMPANY NAME TBD ADDRESS LINE 1 ADDRESS LINE 2 CITY, STATE XXXXX (XXX) XXX-XXXX CONTACT (XXX) XXX-XXXX XXX@XXX.XXX CONTACT (XXX) XXX-XXXX XXX@XXX.XXX P 858.638.7277 3911 SORRENTO VALLEY BLVD, #120 SAN DIEGO, CA 92121 PRIMARY CONTACT: PH: EMAIL: ALTERNATE CONTACT: PH: EMAIL: KARA BURGER kburger@waremalcomb.com (858) 638-7227 X1350 cbuendia@waremalcomb.com CLARISSA BUENDIA (858) 638-7227 X1343 G.C. INSTRUCTIONS 1. AT THE START OF JOB PROVIDE A SCHEDULE OF ALL ANTICIPATED SUBMITTALS AND DATES. FLAG SUBMITTALS WHICH ARE OR COULD BE CRITICAL PATH. FLAG SUBMITTALS THAT WILL BE REQUESTED TO BE EXPEDITED FASTER THAN THE STANDARD 7-10 DAYS. 2. A SUBMITTAL LOG IS TO BE MAINTAINED BY THE GENERAL CONTRACTOR AND A CURRENT COPY IS TO BE INCLUDED WITH EACH SUBMISSION. 3. ALL SUBMITTALS MUST BE REVIEWED AND APPROVED WITH A STAMP AND SIGNATURE BY THE GENERAL CONTRACTOR PRIOR TO SUBMISSION. THE REVIEW WILL INCLUDE BUT NOT BE LIMITED TO: 3.1. CONFIRMING THAT THE SUBMITTAL MEETS THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 3.2. COORDINATION HAS TAKEN PLACE WITH ALL INTERCONNECTING TRADES 3.3. THE SUBMITTAL IS COMPLETE AND COMPREHENSIVE 3.4. REQUESTS ON SUBMITTALS FOR DIMENSIONS WHICH CAN BE DISCERNABLE THROUGH MATHEMATICAL MEANS FROM INFORMATION ALREADY PROVIDED ON THE CONTRACT DOCUMENTS WILL NOT BE PROVIDED. 3.5. SUBMITTALS SHALL BE IN ELECTRONIC FORMAT UNLESS PHYSICAL SAMPLES ARE REQUESTED. 4. SUBMITTALS NOT REQUESTED BY THE CONTRACT DOCUMENTS MAY OR MAY NOT BE REVIEWED AT THE DESIGN TEAM'S DISCRETION. 5. SUBMITTALS ARE TO BE ROUTED THROUGH THE ARCHITECT AND ARE NOT TO BE SENT DIRECTLY TO ARCHITECT'S CONSULTANTS UNLESS SPECIFICALLY AUTHORIZED BY THE ARCHITECT. 6. MINOR CHANGES IN THE WORK MAY OCCUR AS A RESULT OF THE DESIGN TEAM'S REVIEW. IF A CHANGE RESULTS IN MODIFICATIONS TO THE CONTRACT PRICE OR SCHEDULE, THE CONTRACTOR WILL ISSUE A CHANGE ORDER REQUEST FOR REVIEW AND APPROVAL BY THE OWNER AND ARCHITECT PRIOR TO PROCEEDING. SUBMITTALS 1. THE GENERAL CONTRACTOR IS TO REVIEW ALL PROSPECTIVE RFI's AND MAKE EVERY EFFORT TO ANSWER THEM BEFORE SUBMITTING TO THE DESIGN TEAM. 2. MINOR CHANGES IN THE WORK MAY OCCUR AS A RESULT OF THE DESIGN TEAM'S REVIEW. IF A CHANGE RESULTS IN MODIFICATIONS TO THE CONTRACT PRICE OR SCHEDULE, THE CONTRACTOR WILL ISSUE A CHANGE ORDER REQUEST FOR REVIEW AND APPROVAL BY THE OWNER AND ARCHITECT PRIOR TO PROCEEDING. 3. AN RFI LOG IS TO BE MAINTAINED BY THE GENERAL CONTRACTOR AND A CURRENT COPY IS TO BE INCLUDED WITH EACH RFI SUBMISSION ALONG WITH ANY CRITICAL RESPONSE DUE DATES. 4. RFI's REGARDING METHODS AND MEANS OF CONSTRUCTION WILL NOT BE REVIEWED AND WILL BE REMOVED FROM THE RFI LOG. REQUESTS FOR INFORMATION (RFI's) 1. A COMPLETE SCHEDULE OF VALUES OF THE BASE CONTRACT IS TO BE PROVIDED TO THE OWNER AND ARCHITECT PRIOR TO THE START OF ANY WORK. 2. ALL CHANGE ORDER REQUESTS ARE TO BE REVIEWED AND APPROVED BY THE OWNER AND ARCHITECT PRIOR TO SUBMISSION OF A CHANGE ORDER. 3. CHANGE ORDER REQUESTS ARE TO INCLUDE A COMPLETE BREAKDOWN BY TRADE ALONG WITH TRADE BACK-UP AND UNIT PRICING WHERE APPLICABLE. 4. A CHANGE ORDER REQUEST AND CHANGE ORDER LOG IS TO BE MAINTAINED BY THE GENERAL CONTRACTOR AND SUBMITTED ALONG WITH EACH CHANGE ORDER REQUEST. CHANGE ORDERS PRE-CONSTRUCTION NOTES 1. PRIOR TO START OF CONSTRUCTION, A PRE-CONSTRUCTION MEETING IS TO BE HELD INCLUDING A RESPONSIBLE REPRESENTATIVE OF THE ARCHITECT, THE OWNER AND THE GENERAL CONTRACTOR. THE DISCUSSION WILL BE IN REGARDS TO THE ARCHITECT-OWNER-CONTRACTOR (AOC) CORRESPONDENCE PROCESSES AND PROCEDURES. AT A MINIMUM, THE FOLLOWING IS TO BE DISCUSSED: 2. AOC REGULARLY SCHEDULED MEETINGS 2.1. WHEN 2.2. WHERE 2.3. HOW OFTEN 2.4. IN PERSON VERSUS CONFERENCE CALLS 2.5. APPROXIMATE ALLOTTED TIME PER MEETING 3. CONSTRUCTION MEETING MINUTES 3.1. FORMAT FOR THE MINUTES 3.2. CONTRACTOR TO AUTHOR THE MINUTES 4. FORMAL CHANGES IN THE WORK 4.1. ADDENDA AND BULLETINS ISSUED BY THE ARCHITECT 4.2. CHANGE ORDER REQUESTS ISSUED BY THE CONTRACTOR 4.3. CHANGE ORDERS ISSUED BY THE CONTRACTOR 4.4. TRACKING MECHANISMS 5. REQUESTS FOR INFORMATION PROCESS 5.1. TRACKING MECHANISM 5.2. DEFINE Cc: RECIPIENT LIST 5.3. STANDARD RESPONSE TIMES (2-5 WORKING DAYS IS STANDARD) 6. SUBMITTAL PROCESS 6.1. TRACKING MECHANISM 6.2. ISSUANCE SCHEDULE BY THE CONTRACTOR 6.3. DEFINE Cc RECIPIENT LIST 6.4. STAMPED REVIEWED AND APPROVED BY CONTRACTOR PRIOR TO SUBMISSION 6.5. NON-REQUESTED SUBMITTALS MAY NOT BE REVIEWED 6.6. STANDARD RESPONSE TIMES (7-10 WORKING DAYS IS STANDARD) 7. SUBSTITUTIONS 7.1. REQUEST FORMS WITH REASONS AND BENEFIT FOR SUBSTITUTION 8. PAYMENT APPLICATIONS 8.1. PROCESS 8.2. SUBMITTAL DATE 8.3. ANTICIPATED TURN-AROUND 9. PUNCH LISTS 9.1. ONLY ONE PUNCH WALK TO BE PROVIDED BY DESIGN TEAM 9.2. CONTRACTOR TO PUNCH AND MAKE CORRECTIONS OR CREATE A MINIMAL LIST OF CORRECTIONS PRIOR TO DESIGN TEAM PUNCH. 9.3. A FINAL WALK WILL OCCUR ONLY IF THE ARCHITECT IS CONTRACTED TO DO SO. 1. A COMPLETE CONSTRUCTION SCHEDULE OF ALL PORTIONS OF THE WORK TO BE PROVIDED TO THE OWNER AND ARCHITECT PRIOR TO START OF ANY WORK. 2. THE SCHEDULE SHALL NOT EXCEED TIME LIMITS CURRENT UNDER THE CONTRACT DOCUMENTS. 3. THE SCHEDULE SHALL BE REVISED AT APPROPRIATE INTERVALS AS REQUIRED BY THE CONDITIONS OF THE WORK AND PROJECT AND THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT IF FOR ANY REASON THE SCHEDULE IS EXTENDED. 4. A THREE WEEK LOOK-AHEAD SHALL BE REVIEWED REGULARLY AT EACH AOC MEETING WHICH WILL BE IN-LINE WITH THE OVERALL CONSTRUCTION SCHEDULE. PROJECT SCHEDULE DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L SYMBOLS ANGLE CENTERLINE # POUND or NUMBER & AND (E) EXISTING @ AT ~ DIAMETER or ROUND Ø DIAMETER A.D. AREA DRAIN ACOUS. ACOUSTICAL ACT. ACOUSTICAL TILE ADJ. ADJUST, ADJUSTABLE or ADJACENT AFF. ABOVE FINISH FLOOR AGGR. AGGREGATE AL. ALUMINUM APPROX. APPROXIMATE(LY) ARCH. ARCHITECTURAL ASB. ASBESTOS ASPH. ASPHALT B.O.C. BOTTOM OF CONCRETE B.O.D. BOTTOM OF DECK B.O.M. BOTTOM OF MULLION B.O.P. BOTTOM OF PANEL B.O.R. BOTTOM OF REVEAL B/S. BUILDING STANDARD BD. BOARD BITUM. BITUMINOUS BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING BM. BEAM BOT. BOTTOM C.B. CATCH BASIN C.G. CORNER GUARD C.I. CAST IRON C.O. CASED OPENING C.O.M. CENTER OF MULLION C.O.R. CENTER OF REVEAL C.W. COLD WATER CAB. CABINET CEM. CEMENT(ITIOUS) CER. CERAMIC CFCI. CONT. FURNISHED / CONT. INSTALLED CFOI. CONT. FURNISHED / OWNER. INSTALLED CLG. CEILING CLKG. CAULKING CLO. CLOSET CLR. CLEAR CNTR. COUNTER COL. COLUMN CONC. CONCRETE CONN. CONNECTION CONSTR. CONSTRUCTION CONT. CONTINUOUS CONTR. CONTRACTOR CORR. CORRIDOR CPT. CARPET CTR. CENTER CTSK. COUNTER-SUNK D. DEEP D.F. DRINKING FOUNTAIN D.O. DOOR OPENING D.S. DOWNSPOUT D.S.P. DRY STANDPIPE DBL. DOUBLE DEPT. DEPARTMENT DET. DETAIL DIA. DIAMETER DIAG. DIAGNONAL DIFF. DIFFUSER DIM. DIMENSION DISP. DISPENSER DN. DOWN DR. DOOR DWG. DRAWING DWR. DRAWER E. EAST E.J. EXPANSION JOINT E.P. ELECTRIC PANELBOARD E.W.C. ELECTRIC WATER COOLER EA. EACH EL. ELEVATION ELEC. ELECTRIC(AL) ELEV. ELEVATOR EMER. EMERGENCY ENCL. ENCLOSED or ENCLOSURE EQ. EQUAL EQPT. EQUIPMENT EXP. EXPANSION EXPO. EXPOSED EXST. EXISTING EXT. EXTERIOR F.A. FIRE ALARM F.B. FLAT BAR F.D. FLOOR DRAIN F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.F.E. FINISH FACE ELEVATION F.H.C. FIRE HOSE CABINET F.O.C. FACE OF CONCRETE F.O.CMU. FACE OF CONCRETE MASONRY UNIT F.O.F. FACE OF FINISH F.O.IMP. FACE OF INSULATED METAL PANEL F.O.M. FACE OF MULLION F.O.SH. FACE OF SHEATHING F.P. FIREPROOF F.S. FULL SIZE FDN. FOUNDATION FIN. FINISH(ED) FL. FLOOR FLASH. FLASHING FLUOR. FLUORESCENT FT. FOOT or FEET FTG. FOOTING FURR. FURRING FUT. FUTURE G.B. GRAB BAR G.C. GENERAL CONTRACTOR GA. GAUGE GALV. GALVANIZED GL. GLASS GND. GROUND GR. GRADE GYP. GYPSUM H.B. HOSE BIBB H.C. HOLLOW CORE H.M. HOLLOW METAL HDWD. HARDWOOD HDWE. HARDWARE HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT I.D. INSIDE DIMENSION INSUL. INSULATION or INSULATED INT. INTERIOR JAN. JANITOR JT. JOINT ABBREVIATIONS K.O. KNOCK-OUT KIT. KITCHEN LAB. LABORATORY LAM. LAMINATE(D) LAV. LAVATORY LKR. LOCKER LT. LIGHT M.C. MEDICINE CABINET M.O. MASONRY OPENING MAX. MAXIMUM MECH. MECHANICAL MEMB. MEMBRANE MET. METAL MFR. MANUFACTURER MH. MANHOLE MIN. MINIMUM MIR. MIRROR MISC. MISCELLANEOUS MTD. MOUNTED MUL. MULLION N. NORTH N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE NO. NUMBER NOM. NOMINAL O.A. OVERALL O.C. ON CENTER O.D. OUTSIDE DIAMETER OBS. OBSCURE OFCI. OWNER FURNISHED / CONT. INSTALLED OFF. OFFICE OFOI. OWNER FURNISHED / OWNER INSTALLED OPNG. OPENING OPP. OPPOSITE P.C. PRECAST P.J. PANEL JOINT P.LAM. PLASTIC LAMINATE P.T.D. PAPER TOWEL DISPENSER P.T.R. PAPER TOWER RECEPTACLE PL. PLATE PLAS. PLASTER PLYWD. PLYWOOD PR. PAIR PT. POINT PTN. PARTITION Q.T. QUARRY TILE R. RISER R.D. ROOF DRAIN R.O. ROUGH OPENING R.W.L. RAIN WATER LEADER RAD. RADIUS REF. REFERENCE REFR. REFRIGERATOR REINF. REINFORCE(D) REQ. REQUIRED RESIL. RESILIENT RGTR. REGISTER RM. ROOM RWD. REDWOOD S. SOUTH S.C. SOLID CORE S.C.D. SEAT COVER DISPENSER S.D. SOAP DISPENSER S.N.D. SANITARY NAPKIN DISPENSER S.N.R. SANITARY NAPKIN RECEPTACLE S.S. STAINLESS STEEL S.SK. SERVICE SINK SCHED. SCHEDULE SECT. SECTION SH. SHELF SHR. SHOWER SHT. SHEET SIM. SIMILAR SPEC. SPECIFIED or SPECIFICATION SQ. SQUARE STA. STATION STL. STEEL STOR. STORAGE STRL. STRUCTURE or STRUCTURAL SUSP. SUSPENDED SYMM. SYMMETRICAL T&G TONGUE AND GROOVE T. TREAD T.B. TOWEL BAR T.C. TOP OF CURB T.O.C. TOP OF CONCRETE T.O.M. TOP OF MULLION T.O.P. TOP OF PARAPET T.O.R. TOP OF REVEAL T.O.REC. TOP OF DEEP RECESS T.O.W. TOP OF WALL T.P. TOP OF PAVEMENT T.P.D. TOILET PAPER DISPENSER T.V. TELEVISION TEL. TELEPHONE TER. TERRAZZO THK. THICK TYP. TYPICAL U.O.N. UNLESS OTHERWISE NOTED UNF. UNFINISHED UR. URINAL VERT. VERTICAL VEST. VESTIBULE W. WEST W.C. WATER CLOSET W/ WITH W/O WITHOUT WD. WOOD WP WATERPROOF WSCT. WAINSCOT WT. WEIGHT Bldg permit #'s 101113828-29 Approved by A. So on 3/27/23 Planning approved on 4/3/23 by F. Arias PW approved on 4/13/23 by B. Sarlak Police approved on 4/18/23 by B. Martin Elect permit #20178695 approved by M.Smith on 3/24/23 Plumb permit #30145465 - No p/c req'd Mech permit#40137657 - No p/c req'd Permits issued on 4/20/23 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 4 0 P M K. BURGER CB / JG SDG22-6057-00 GE N E R A L N O T E S I0.2 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 MILLWORK NOTES 1. CONTRACTOR MUST NOTIFY BUILDING OWNER/MANAGER OF ANY DISCREPANCY IN PLANS. FINISH ITEMS CLEARLY SHOWN IN PLANS, BUT OMITTED FROM SCHEDULES OR LEGENDS MUST STILL BE PROVIDED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO VERIFY OMITTED FINISHES WITH BUILDING OWNER/MANAGER PRIOR TO ORDERING PRODUCTS. 2. SHOP DRAWINGS MUST BE PROVIDED FOR APPROVAL PRIOR TO FABRICATION ANY SUBSTITUTIONS MUST BE APPROVED BY THE ARCHITECT PRIOR TO FABRICATION. 3. MILLWORKER TO COORDINATE & VERIFY WITH CONTRACTOR FINAL LOCATION FOR CANTILEVERED COUNTERS FOR IN-WALL SUPPORT BRACKETS, PRIOR TO GYPSUM BOARD FINISHING OF WALLS. ALL FINAL INSTALLATION HEIGHTS FOR IN-WALL SUPPORT BRACKETS MUST MEET ALL APPLICABLE ACCESSIBILITY CODES AND STANDARDS WITH COUNTERTOP MATERIAL THICKNESS INCLUDED. 4. MATERIAL COLORS NOT LISTED SHALL BE REQUESTED FROM THE ARCHITECT ON SHOP DRAWING SUBMITTALS OR VIA RFIs. 5. ALL UPPERS TO BE LAMINATED TO MATCH BASE CABINETS. BOTH UPPERS & LOWER CABINETS IN WET AREAS TO HAVE MATCHING PVC EDGE, ALL OTHERS TO HAVE PLASTIC LAMINATE EDGE BANDING U.O.N. 6. ALL CABINETS AND DOORS SHALL BE CONSTRUCTED FROM 3/4" THICK MATERIAL, U.O.N. ON DETAILS. 7. BASE CABINETS ARE NOT TO RECEIVE WALL BASE UNLESS INDICATED ON FINISH PLANS OR ELEVATIONS. 8. ALL INTERIORS OF CLOSED CABINETS TO BE WHITE MELAMINE/POLYESTER OR APPROVED EQUAL, UNLESS OTHERWISE SPECIFIED. 9. ALL OPEN CABINETS OR SHELVES TO HAVE PLASTIC LAMINATE TO MATCH EXTERIORS. 10. NO 3/4" THICK SHELF SHALL SPAN LONGER THAN 32" WITHOUT SUPPORT. 11. ALL SHELVING TO BE ADJUSTABLE UNLESS OTHERWISE SPECIFIED. 12. ALL FILE PEDESTALS ARE TO BE CONFIGURED FOR "FRONT TO BACK" FILING AND BE ABLE TO ACCEPT METAL HANGERS TO ACCEPT PENDAFLEX TYPE FILE FOLDERS, UNLESS NOTED AS LATERAL. 13. ALL COUNTER TOPS TO BE 24" DEEP, UNLESS OTHERWISE SPECIFIED. WHERE NO BACKSPLASH IS SPECIFIED, COUNTER TOPS TO BE SCRIBED TIGHTLY TO BACK & SIDE WALLS. 14. ALL BACKSPLASHES TO BE SCRIBED TO WALLS, AND MUST BE FLUSH TO EDGE OF BASE, UNLESS OTHERWISE SPECIFIED. ALL COUNTER TRANSITION SEAMS MUST BE CAULKED SEALED, VERIFY EITHER MATCHING COLOR CAULK OR CLEAR SILICONE. 15. PROVIDE SIDE SPLASHES AT LOCATIONS ADJACENT TO WALLS OR WINDOWS, ESPECIALLY FOR SINKS U.O.N. 16. FACES OF PIGEONHOLES TO MATCH WORK SURFACE LAMINATE. COLOR OF EDGE BANDING ON ALL DOORS TO MATCH FACE MATERIAL. 17. IF PROVIDED, SEE SPECIFICATIONS/PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS. 18. COUNTERTOPS SHALL HAVE A NOSING OF COUNTERTOP MATERIAL AT LEAST 3" DEEP, WHEREBY THE COUNTER MATERIAL EXTENDS INTO THE INSIDE OF THE CABINET, I.E. OVER THE DOOR (WHEN PRESENT). 19. END PANELS AND FRONT EDGES OF EDGE PANELS WHICH ARE PROUD OF THE INTERIOR CABINET SHALL BE FACED TO MATCH DOOR FRONTS. 20. ALL HINGED DOORS TO HAVE CLEAR SILENCERS TOP AND BOTTOM ON DOOR (NOT CABINET). 21. ALL DRAWERS GLIDES SHALL HAVE SILENCERS BUILT INTO THE GLIDE AND NOT INSTALLED ON THE DRAWER OR DRAWER FRONT. 22. ALL DRAWER GLIDES SHALL BE FULL EXTENSION. 23. PROVIDE FULL OVERLAY HINGES THAT OPEN ±105°, EXCEPT WHERE CABINETS ARE ADJACENT TO THE WALLS. PROVIDE HINGES WHICH LIMIT THE DOOR SWING TO KEEP THE DOOR PULL FROM DAMAGING THE WALL. 1. VERIFY THAT ALL DOORS AND DOOR HARDWARE MEET THE REQUIREMENTS OF ALL GOVERNING CODES & STANDARDS. NOTIFY THE ARCHITECT IMMEDIATELY IN CASE OF DISCREPANCY. 2. FIELD MEASURE AS REQUIRED ALL DOORS AND/OR DOOR OPENINGS PRIOR TO FABRICATION. 3. PROVIDE SIGN IN CONTRASTING LETTERS OF 1 INCH OR MORE AT MAIN ENTRY STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" UNLESS LOCK UNLATCHES WITHOUT A KEY OR NEED OF SPECIAL KNOWLEDGE. 4. VERIFY THAT EXISTING DOORS COMPLY WITH ACCESSIBILITY REQUIREMENTS. 5. FIRE RATED AND SMOKE AND DRAFT CONTROL DOORS SHALL COMPLY WITH REQUIREMENTS OF ALL GOVERNING CODES & STANDARDS AND SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATINGS. 6. ALL SWINGING DOOR HANDLES TO BE LEVER-TYPE TO COMPLY WITH GOVERNING CODES & ACCESSIBILITY STANDARDS. 7. DOOR HANDLES OR PULLS AND ALL OTHER OPERABLE PARTS OF DOOR HARDWARE (SUCH AS DEADBOLTS, KEYHOLES... ETC.) ARE TO BE CENTERED BETWEEN 34" AND 44" ABOVE FINISH FLOOR. IF EXISTING BUILDING STANDARD EXISTS, MATCH BUILDING STANDARD AND CONFIRM COMPLIANCE WITH ACCESSIBILITY REQUIREMENTS. 8. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE BY AUTHORITY HAVING JURISDICTION. 9. PROVIDE WEATHER SEALS ON ALL EXTERIOR DOORS PER ANSI STANDARDS. 10. CONTRACTOR IS RESPONSIBLE TO COORDINATE & VERIFY ALL DOOR FRAME THROAT THICKNESSES FOR EACH LOCATION. 11. ALL DOOR FRAMES TO BE FACTORY FINISHED, U.O.N. 12. PROVIDE 6”x16 GA MIN FLAT METAL OR 2x6 BACKING (FRT AS REQUIRED) BEHIND ALL WALL MOUNTED DOOR STOPS. 13. MAXIMUM UNDERCUT OF ALL NON-FIRE RATED DOORS SHALL NOT EXCEED 1/2" ABOVE FINISH FLOOR SURFACE. 14. CONTRACTOR SHALL REFINISH ANY BLEMISHED DOOR OR REPLACE SAID DOOR IF NOT ABLE TO REFINISH TO "AS NEW" CONDITION. 15. ALL DOORS TO BE OPERABLE FROM THE INSIDE WITHOUT A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT 16. ALL DOORS WITH ELECTRONIC SECURITY DOOR LOCKS MUST BE OPERABLE FOR EXITING PURPOSES UNDER ALL CONDITIONS. INCLUDING A POWER OUTAGE. 17. IF BUILDING STANDARDS ARE INCONSISTENT FOR DOORS, SIDELITES, HARDWARE, DOOR AND SIDELITE FRAMES OR OTHER STANDARD DETAILS, THEN CONTRACTOR MUST VERIFY WITH ARCHITECT AND OWNER PRIOR TO CONSTRUCTION. DOOR NOTES GLAZING NOTES 1. EACH LIGHT SHALL BEAR THE MANUFACTURER'S LABEL DESIGNATING THE TYPE AND THICKNESS OF THE GLASS. 2. GLASS SHALL BE FIRMLY SUPPORTED ON ALL FOUR EDGES, U.O.N. 3. FIELD MEASURE ALL OPENINGS PRIOR TO FABRICATION. 4. FIXED OR OPERABLE GLAZING IN HAZARDOUS LOCATIONS AS DEFINED IN THE BUILDING CODE SHALL BE TEMPERED GLASS (SAFETY GLASS). 5. GLAZING IN SWINGING, SLIDING AND BIFOLD DOORS SHALL BE TEMPERED. 6. ALL GLAZING WITHIN A 24" ARC OF EITHER EDGE OF A DOOR AND WITHIN 60" OF THE FLOOR SHALL BE TEMPERED. 7. GLAZING IN WINDOWS: ALL GLAZING THAT MEETS ALL OF THE FOLLOWING CONDITIONS SHALL BE TEMPERED: A. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 SF. B. THE BOTTOM EDGE IS LESS THAN 18" ABOVE THE FLOOR. C. THE TOP EDGE IS GREATER THAN 36" ABOVE THE FLOOR. D. WALKING SURFACE IS WITHIN 36". 8. ALL GLASS SHALL COMPLY WITH THE REQUIREMENTS OF THE STATE AND LOCAL CODES AND THE U.S. PRODUCT SAFETY COMMISSIONS: SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS. 9. WHERE JOINTS ARE REQUIRED IN MULTIPLE LITES, CLEAR SILICONE IS TO BE PROVIDED, U.O.N. 1. CONTRACTOR AND ARCHITECT TO REVIEW & APPROVE CHALK LINES OF PARTITION LAYOUT PRIOR TO COMMENCEMENT OF PARTITION CONSTRUCTION. 2. CONTRACTOR TO VERIFY DIMENSIONS FOR ALL PLUMBING PARTITIONS. 3. EXTEND ALL STUDS AND WALL MATERIALS TO CONSTRUCTION ABOVE, U.O.N. 4. ALL CONDUIT PIPING TO BE CONCEALED WITHIN THE WALL CONSTRUCTION. 5. DOOR OPENINGS IN PARTITIONS NOT DIMENSIONED ARE TO BE LOCATED WITHIN 4" OF ADJACENT PERPENDICULAR PARTITION. 6. CONTRACTOR SHALL USE 6" METAL STUDS MINIMUM AT ALL PLUMBING WALLS. CONTRACTOR TO VERIFY ACTUAL DEPTH REQUIRED, ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT. 7. USE WATER RESISTANT GYPSUM BOARD AT ALL AREAS SUBJECT TO MOISTURE OR WHERE TILE IS USED. 8. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. 9. ALL HOT WATER LINES SHALL BE PROPERLY INSULATED. SEE PLUMBING DRAWINGS. 10. ALL PLUMBING CLEAN-OUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL CLEAN-OUT LOCATIONS WITH EQUIPMENT, AND CABINETS. SUBMIT A PLAN OF ALL PROPOSED LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 11. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ARCHITECT AND TENANT APPROVAL PRIOR TO MANUFACTURE OF ANY CABINET WORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP PREFABRICATION WORK. 12. PROVIDE AND INSTALL ALL NECESSARY WALL BACKING, STIFFENERS, BRACING, BACK- UP PLATES AND/ OR SUPPORTING BRACKETS AS REQUIRED FOR THE INSTALLATION OF WALL-MOUNTED OR SUSPENDED EQUIPMENT OR BUILT-IN ITEMS. VERIFY REQUIREMENTS WITH MANUFACTURERS PRIOR TO INSTALLATION. SUPPLY CATALOG CUT SHEETS FOR ARCHITECT'S APPROVAL. 13. PROVIDE AND INSTALL ALL NECESSARY ELECTRICAL CONNECTIONS AND PLUMBING SUPPLY, FITTINGS & CONNECTORS TO COMPLETE INSTALLATION OF APPLIANCES & EQUIPMENT INDICATED ON PLAN. VERIFY REQUIREMENTS WITH MANUFACTURERS PRIOR TO INSTALLATION. SUPPLY CATALOG CUT SHEETS FOR ARCHITECT'S APPROVAL. 14. EXACT LOCATION OF FIRE EXTINGUISHER CABINETS TO BE CONFIRMED WITH ARCHITECT BEFORE INSTALLATION. PROVIDE ADDITIONAL FIRE EXTINGUISHERS & CABINETS AS REQUIRED BY THE FIRE DEPARTMENT FIELD INSPECTORS. 15. UNLESS OTHERWISE NOTED, ALL GYPSUM BOARD SURFACES, WALLS, AND CEILINGS SHALL BE TAPED, SANDED SMOOTH TO A "LEVEL 4" FINISH, SO AS TO RECEIVE PAINT OR WALL COVERING MATERIAL. 16. PROVIDE SOUND INSULATION AT PERIMETER WALLS OF RESTROOMS, LOBBY, STAIRS, AND ACROSS CEILING OF RESTROOMS TO CREATE AN ACOUSTIC ENVELOPE, U.O.N. 17. PATCH AND FILL OPENINGS AT EXISTING GYPSUM BOARD PARTITIONS AND SOFFITS FOLLOWING REMOVAL OR INSTALLATION OF ANY SURFACE MOUNTED OR RECESSED FURNISHINGS, RECEPTACLES, UTILITY PIPING, SHELF STANDARDS & ALL OTHER SIMILAR ELEMENTS INDICATED TO BE REMOVED DURING THE DEMOLITION PHASE OR INSTALLED DURING THE CONSTRUCTION PHASE: TAPE AND SEAL ALL SEAMS WITH JOINT COMPOUND: APPLY NEW FINISH TO MATCH EXISTING FINISH AT ADJACENT GYPSUM BOARD SURFACES AND FEATHER NEW FINISH WITH EXISTING FINISH TO PROVIDE CONSISTENT & CONTINUOUS FINISH. 18. THE MAXIMUM CONTROL JOINT SPACING FOR WALLS AND CEILINGS WITHOUT PERIMETER RELIEF IS TO BE 30 LINEAR FEET OR 900 SQUARE FEET OF SURFACE AREA, WITH PERIMETER RELIEF IS TO BE 50 LINEAR FEET OR 2,500 SQUARE FEET OF SURFACE AREA. EXTERIOR JOINT SPACING IS TO BE 30 LINEAR FEET OR 900 SQUARE FEET OF SURFACE AREA. 19. CONSTRUCTION SEALANT JOINTS ARE REQUIRED AT CONTINUOUS GYPSUM BOARD SURFACES WITH DISSIMILAR WALL STRUCTURE. 20. PROVIDE DOUBLE STUDS AT BOTH JAMBS OF DOOR FRAMES AND HEADER. 21. PARTITIONS SHALL NOT BE FASTENED NOR BRACED TO DUCTWORK, CONDUIT OR PIPING. 22. DO NOT MECHANICALLY SECURE NEW STUD FRAMING TO EXISTING WINDOW FRAMES. FLOOR PLAN NOTES POWER & SIGNAL NOTES 1. COORDINATE TELEPHONE/DATA INSTALLATION WITH APPROPRIATE SUB-CONTRACTOR. 2. ALL EXISTING ELECTRICAL DEVICES ARE TO REMAIN, UNLESS NOTED OTHERWISE. REPLACE DEVICE AND PLATE TO MATCH NEW AS REQUIRED. 3. ALL OUTLETS TO BE INSTALLED AT LOCATIONS SHOWN BY DIMENSIONS ON THE POWER & SIGNAL PLAN OR REFERENCED ELEVATIONS. DIMENSION ALL OUTLETS FROM THE CENTERLINE OF THE OUTLET BOX. NON-DIMENSIONED OUTLETS ARE TO BE LOCATED AT THE NEAREST WALL STUD. 4. WHEN OUTLETS ARE GROUPED TOGETHER (2 OR MORE), THEY ARE TO BE SPACED NO MORE THAN 2" APART. 5. ALL ELECTRICAL OUTLETS OF 30 AMPERES OR LESS SHALL BE MOUNTED BETWEEN +15" TO BOTTOM RECEPTACLE AND +48" TO TOP OF RECEPTACLE FROM FINISH FLOOR. SEE NOTE 6, BELOW, FOR GENERAL MOUNTING HEIGHT. 6. ALL NEW WALL MOUNTED 15, 20, AND 30 AMP OUTLETS/RECEPTACLES TO BE CENTERED AT 18" A.F.F., U.O.N. 7. NO RECEPTACLES OR JUNCTION BOXES WITHIN A PARTITION/WALL ARE TO BE BACK-TO-BACK SERVING OPPOSITE SIDES OF THE WALL. RECEPTACLES MUST BE STAGGERED, SET APART BY AT LEAST 4" TO ALLOW FOR INSULATION. 8. ANY NEW VOICE/DATA AND ELECTRICAL OUTLETS TO BE INSTALLED IN EXISTING DRYWALL PARTITIONS TO BE FLUSH MOUNTED WITH THE FINISHED WALL SURFACE AND WALL PATCHED AS REQUIRED. SHOULD THE WALL DEPTH NOT BE ADEQUATE, COORDINATE WITH THE ARCHITECT AN ALTERNATE LOCATION. 9. LOCATIONS OF FURNITURE POWER FEEDS SHALL ACCOMMODATE CIRCUITS AND WIRE PER ELECTRICAL DRAWINGS. TENANT SHALL BE RESPONSIBLE FOR PROVIDING FURNITURE POWER FEED, GENERAL CONTRACTOR SHALL INSTALL THE POWER FEED. 10. WHERE DEDICATED ELECTRICAL OUTLETS ARE NOTED WITHIN THE FURNITURE PANEL SYSTEM, THE PANEL SYSTEM SHALL ACCOMMODATE THIS REQUIREMENT. 11. WHERE ELECTRICAL WORK IS SPECIFIED IN CONJUNCTION WITH MILLWORK, LAMPS AND FIXTURES ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. 12. CUT-OUTS FOR SWITCHES, OUTLETS, ETC. AS REQUIRED BY THE MILLWORKER ARE TO BE COORDINATED WITH THE ELECTRICAL CONTRACTOR, U.O.N. ALL RECEPTACLES WHERE MILLWORK OCCURS SHALL BE LOCATED PER ELEVATIONS OF THE MILLWORK ITEM IN QUESTION. 13. ALL WALL COVER PLATES SHALL BE WHITE, U.O.N. 14. ALL SEPARATE CIRCUIT RECEPTACLES TO BE ORANGE COLOR WITH BUILDING STANDARD COLOR COVER PLATE. 15. ALL/ANY FLOOR CORE DRILL LOCATIONS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO DRILLING. ALL UNUSED CORE DRILLS SHALL BE PLUGGED AND CAPPED AS REQUIRED TO MAINTAIN FLOOR FIRE RATING. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK NECESSARY TO COMPLETE CORE DRILLING AND ELECTRICAL HOOKUP INCLUDING WORK IN LANDLORD’S OR OTHER TENANT’S SPACE. 17. PRIOR TO CUTTING OPENINGS IN THE FLOOR, CONTRACTOR TO PROVIDE SURVEY/X-RAYS TO VERIFY BEAM, JOISTS, REBAR AND EXISTING CONDUIT LOCATIONS. MARK ALL CORE DRILL LOCATIONS AND RECEIVE STRUCTURAL ENGINEER AND/OR BUILDING OWNER’S APPROVAL PRIOR TO DRILLING. 18. ALL NEW WALL OUTLETS ABOVE COUNTERTOP TO BE MOUNTED HORIZONTALLY 6” ABOVE COUNTER U.O.N. 19. TEMPORARY LIGHTING TO BE PROVIDED AS REQUIRED DURING CONSTRUCTION. 20. REFER TO REFLECTED CEILING PLANS FOR LIGHT FIXTURES UNDER OVERHEADS AT MILLWORK AND CUSTOM FURNITURE. 21. REFER TO POWER PLAN FOR LIGHT FIXTURES MOUNTED IN SYSTEMS FURNITURE. 22. CONTRACTOR TO PROVIDE BACKBOXES AND CONDUIT TO ABOVE CEILING ONLY FOR LOW VOLTAGE DEVICES LOCATED IN WALLS AND HARD CEILINGS. DEVICES AND CABLING ARE BY OTHERS. COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR LOCATIONS AND REQUIREMENTS. CEILING NOTES 1. SEE ELECTRICAL ENGINEERING DRAWINGS FOR SPECIFICATIONS OF LIGHT FIXTURES, SWITCHES, EXIT SIGNS, ETC. 2. CONTRACTOR TO VERIFY COMPATIBILITY OF LIGHT FIXTURES WITH THE CEILING SYSTEM. 3. ALL REPLACEMENT FLUORESCENT LAMPS TO MATCH BUILDING STANDARD OR ADJACENT EXISTING CONSTRUCTION - SAME COLOR AND MANUFACTURER. 4. FIELD VERIFY EXISTING CEILING GRID LOCATION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES ON PLANS. 5. CONTRACTOR TO PROVIDE APPROPRIATE SIZED CUTOUTS ABOVE CEILINGS WHERE NON- RATED PARTITIONS EXTEND TO SLAB ABOVE AS NECESSARY FOR RETURN AIR CIRCULATION. 6. WHERE DISCREPANCIES IN LOCATION OF LIGHT FIXTURES, AIR DIFFUSERS, GRILLES, ETC. OCCUR ON THE ELECTRICAL PLANS, THE ARCHITECTURAL PLANS SHALL GOVERN. NOTIFY ARCHITECT OF ANY DISCREPANCIES FOR CLARIFICATIONS. 7. FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, ETC. AND NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF LIGHTS ETC. 8. PLACEMENT OF LIGHT FIXTURES IN AREAS WHERE MAIN DUCTS MAY CAUSE INTERFERENCE MUST BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 9. CONDUIT ABOVE CEILING MUST BE A MINIMUM OF 12" ABOVE THE CEILING GRID. 10. NO COMBUSTIBLE MATERIALS SHALL BE USED IN THE PLENUM SPACE, INCLUDING ALUMINUM FLEX, ALUMINUM CONDUIT AND POT METAL CONNECTORS. 11. ALL JUNCTION BOXES AND MECHANICAL EQUIPMENT REQUIRING ACCESS FOR SERVICE SHALL BE LOCATED OVER ACOUSTICAL CEILINGS. NO ACCESS HATCHES SHALL BE INSTALLED IN GYPSUM BOARD CEILINGS WITHOUT PRIOR APPROVAL BY ARCHITECT. (NO EXCEPTION). 12. ALL SPRINKLER HEADS AT HARD-LID CEILINGS ARE TO BE FULLY RECESSED AND CONCEALED. HEADS ARE TO BE CENTERED BETWEEN LIGHTS IN A UNIFORM ARCHITECTURAL PATTERN, G.C TO PROVIDE A SUBMITTAL WITH SPRINKLER HEAD LOCATIONS FOR ARCHITECT'S APPROVAL PRIOR TO INSTALLATION. 13. ALL SPRINKLER HEADS PLACED IN WHITE CEILING TILE OR WHITE GYPSUM BOARD TO BE WHITE. ALL SPRINKLER HEADS IN COLORED CEILINGS ARE TO BE CUSTOM COLOR TO MATCH ADJACENT CEILING. 14. LOCATE RECESSED DOWN LIGHTS, WALL WASHERS, SMOKE DETECTORS, EXIT SIGNS, SPEAKERS, FIRE SPRINKLERS, ETC. IN CENTER OF 24"x24" CEILING TILES OR IN CENTER OF 24"x24" PORTION OF 24"x48" CEILING TILES. UNLESS OTHERWISE NOTED. 15. PROVIDE SWITCHES AND LIGHT SENSORS FOR OPEN AREAS AND PRIVATE OFFICES. ACTUAL LOCATION OF ALL SWITCHES TO BE DETERMINED BY ARCHITECT. 16. PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS OR DUCTS PENETRATING FIRE RATED ASSEMBLIES, ENCLOSURES, WALLS, FLOORS OR SURFACES, AS REQUIRED BY LOCAL CODES AND FIRE DEPARTMENT. REFER TO MECHANICAL ENGINEERING DOCUMENTS FOR SPECIFIC REQUIREMENTS. 17. CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING, STROBE LIGHTS, AUDIO-VISUAL ALARMS AND OCCUPANCY SENSORS TO MEET ALL APPLICABLE CODES. 18. CONTRACTOR SHALL PROVIDE LAMPS WITH TYPE IC RATED HOUSING WHERE FIXTURES COME IN DIRECT CONTACT WITH INSULATION. 19. ALL EXIT SIGN LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECT. 20. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED AT ALL TIMES AND SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM (BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE THE EXIT SIGNS FOR A DURATION OF NOT LESS THAN 90 MINUTES. FINISH NOTES 1. NO FINISH SUBSTITUTIONS MAY BE MADE UNLESS APPROVED BY ARCHITECT. 2. CONTRACTOR MUST NOTIFY THE ARCHITECT OF ANY DISCREPANCY IN PLANS. FINISH ITEMS CLEARLY SHOWN IN PLANS, BUT OMITTED FROM SCHEDULES OR LEGENDS MUST STILL BE PROVIDED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO VERIFY OMITTED FINISHED WITH ARCHITECT PRIOR TO ORDERING PRODUCTS. 3. INSTALL MATERIALS ACCORDING TO MANUFACTURER'S SUGGESTED INSTALLATION AND PREPARATION/MAINTENANCE SPECIFICATIONS OR BETTER, UNLESS OTHERWISE APPROVED OR NOTED. 4. APPLICATION OF CONTROLLED INTERIOR FINISHES SHALL BE IN CONFORMANCE WITH STATE & LOCAL CODES. 5. DECORATIVE MATERIALS SHALL BE MAINTAINED IN FLAME-RETARDANT CONDITION. 6. SUBMIT THE FOLLOWING SAMPLES FOR ARCHITECT'S APPROVAL: A. THREE (3) 12" X 12" SAMPLES FOR ALL PAINT, WALL COVERING FINISHES AND COLORS APPLIED TO A SUBSTRATE WHICH IS REPRESENTATIVE OF THE SURFACE TO BE FINISHED. SUBMIT PAINT SAMPLES FROM THE PAINT LOT OR LOTS INTENDED FOR APPLICATION. B. ONE (1) 24" X 24" MOCK-UP WITH SAMPLE SEAM (CENTERED) OF ALL WALL COVERING FINISHES AND COLOR. C. THREE (3) 12" X 12" SAMPLES OF ALL FLOOR COVERING. D. SUBMIT ACTUAL CUTTINGS OF EACH PRODUCT FOR COLOR/QUALITY CONTROL. 7. WHERE MATERIALS ARE NOT RETURNABLE, SUBMIT SAMPLES TO ARCHITECT AND SECURE APPROVAL BEFORE PLACING FULL ORDERS. 8. SUBMIT SEAMING PLAN FOR CARPET TO ARCHITECT FOR APPROVAL PRIOR TO CARPET ORDER. 9. NOTIFY ARCHITECT IMMEDIATELY OF ITEMS WITH LONG LEAD TIMES. 10. ALL PAINT FINISH OF METAL PARTS OF DOORS, HANDRAILS, PERIMETER ENCLOSURES, ETC. , SHALL BE SEMI-GLOSS, UNLESS NOTED OTHERWISE. 11. WHERE PAINT COLORS CHANGE, CORNERS ARE TO BE CUT-IN FREE OF OVERLAPPING. 12. PRIOR TO THE INSTALLATION OF WALL COVERINGS, SURFACES SHALL BE PROPERLY PREPARED WITH SEALER PER MANUFACTURER'S RECOMMENDATIONS. 13. CONTRACTOR TO VERIFY CONDITION AND LEVEL OF FLOOR SO AS TO RECEIVE NEW FINISHES WITHOUT BOWING AT FLOOR OR WALL BASE. CONTRACTOR IS RESPONSIBLE FOR ALL FLOOR PREPARATION. 14. ALL CARPETING SHALL BE INSTALLED WITH GLUE DOWN METHOD, UNLESS NOTED OTHERWISE. 15. ALL RESILIENT FLOORING TO BE INSTALLED WITH FULL TILE FROM THRESHOLD STRIP AND FULL TILE FROM WALL ADJACENT TO DOOR SWING, U.N.O. 16. PROVIDE AND INSTALL SPECIFIED BASE FOR ALL AREAS TO RECEIVE FLOORING. 17. CONTRACTOR SHALL PROVIDE PRE-FORMED RUBBER BASE CORNERS. DO NOT CUT OR BEND STRAIGHT BASE TO MAKE CORNERS. 18. MILLWORK LOWER CABINETS ARE NOT TO RECEIVE WALL BASE UNLESS INDICATED ON MILLWORK DETAILS. 19. FLOOR FINISHES TO CONTINUE UNDERNEATH "OPEN FLOOR" AREAS OF MILLWORK, INCLUDING SINK AREA AND AT ALL UNDER-COUNTER EQUIPMENT AREAS WHICH ARE OPEN TO THE FLOOR. 20. FLOORS SHALL BE SLOPED TO FLOOR DRAINS. COORDINATE WITH PLUMBING AND STRUCTURAL DRAWINGS. IN RATED FLOOR CONDITIONS, CONFIRM REMAINING FLOOR THICKNESS STILL CONFORMS TO MINIMUM RATING REQUIREMENT. 21. CONTRACTOR TO RUN CALCIUM CHLORIDE TEST ON ALL EXISTING OR NEW CONCRETE SLABS PRIOR TO INSTALLING ANY FLOORING AND COMPARE RESULTS WITH FLOORING MANUFACTURE'S RECOMMENDED MAXIMUM CONTENT FOR WARRANTIES AND ADHESIVE PRODUCTS. 22. PRIOR TO NEW FLOORING INSTALLATION REMOVE EXISTING FLOOR FINISHES. PATCH AND REPAIR SUB-FLOOR AS REQUIRED. PREPARE FLOORS AND TRANSITIONS AS REQUIRED FOR SMOOTH AND LEVEL FINISH PER APPLICABLE BUILDING CODES. 23. ALL FLOORING TRANSITIONS AMONG DIFFERING FLOORING MATERIAL ARE TO BE A FLUSH TRANSITION, U.O.N. 24. FEATHER SUB-FLOOR UP FOR TILE FLOORING TO CARPET CONDITIONS AND RESILIENT FLOORING TO CARPET CONDITIONS FOR FLUSH INSTALLATION. 25. INSTALL METAL TRANSITION STRIPS WHERE TILE MEETS ALL OTHER FLOORING TYPES. PROVIDE LOW PROFILE TRANSITION STRIP WHERE ALL OTHER DIFFERENT FLOOR TYPES MEET, VERIFY COLOR WITH ARCHITECT. 26. FLOOR COVERING INSTALLER TO FOLLOW MANUFACTURER'S SPECIFIED CARPET INSTALLATION INSTRUCTIONS. USING ADHESIVES AND INSTALLATION METHOD TO MAINTAIN PRODUCT'S WARRANTY. CONTACT CARPET SALES REPRESENTATIVE WITH QUESTIONS PRIOR TO PROCEEDING. 27. FLOOR COVERING INSTALLER TO FOLLOW MANUFACTURER'S SPECIFIED CONTOURED RUBBER BASE INSTALLATION INSTRUCTIONS USING ADHESIVES AND INSTALLATION METHODS REQUIRED TO MAINTAIN PRODUCT'S WARRANTY. 28. FLOOR COVERING INSTALLER REQUIRED TO PROVIDE MINIMAL SEAMS/JOINTS AT ALL LOCATIONS FOR FLOOR AND WALL BASE MATERIAL INSTALLATION. PROVIDE LOW VOC, BUT HEAVY DUTY ADHESIVES TO ENDURE HEAVY FOOT TRAFFIC, CARTS AND TO MAINTAIN PRODUCT'S WARRANTY. 29. PRIOR TO PAINTING, WALLS MUST BE PATCHED AND REPAIRED, CLEAN AND DRY AS TO LEAVE NO EVIDENCE OF PATCHING OR REPAIRS. ALL SCREW AND NAIL HEADS MUST BE SET AND SPACKLED. ALL JOINTS MUST BE TAPED AND COVERED WITH JOINT COMPOUND. JOINTS THAT ARE FILLED TO BE SANDED SMOOTH AND DUST REMOVED PRIOR TO RECEIVING NEW PAINT FINISH APPLICATION. 30. PRIOR TO PAINTING OVER WALL COVERING, SECURELY GLUE DOWN ANY LIFTING OR BUCKLING AND HIDE ALL SEAMING OR BUMPS. 31. WALLS TO HAVE AT LEAST ONE COAT OF COLORED PRIMER AND TWO COATS OF SPECIFIED PAINT FINISH TYPE. PAINT TO BE A LOW VOC UNLESS U.O.N. HIGH TRAFFIC/WEAR ABILITY WITH GOOD SCRUB AND CLEANING ABILITY. VERIFY ALL WITH TENANT OR OWNER PRIOR TO PURCHASING PAINT. 32. PAINT ANY UNFINISHED SPEAKER COVERS AND HVAC GRILLS IN GYPSUM BOARD WALLS AND CEILINGS TO MATCH ADJACENT PAINT COLOR AS SPECIFIED. 33. ALL EXPOSED MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION DUCTWORK AND PIPING IS TO BE PAINTED TO MATCH THE CEILING. 34. ALL NEWLY INSTALLED, PATCHED WORK AND ALL AFFECTED AREAS SHALL BE PAINTED. ALL PAINTING WORK SHALL BE PERFORMED TO COVER THE ENTIRE HORIZONTAL OR VERTICAL SURFACE TO THE CLOSEST CORNER IN ALL FOUR DIRECTIONS. 35. PRIOR TO INSTALLING WALL TILES AND WALL BASE TILE, WALLS MUST BE PATCHED AND REPAIRED, CLEAN AND DRY AND BE PROPERLY MEMBERED AND ALIGNED, SO, AS TO LEAVE NO EVIDENCE OF PATCHING OR REPAIRS. ALL SCREW AND NAIL HEADS MUST BE SET AND SPACKLED. ALL JOINTS MUST BE TAPED AND COVERED WITH JOINT COMPOUND. JOINTS THAT ARE FILLED ARE TO BE SANDED SMOOTH AND BUMP FREE WITH DUST REMOVED PRIOR TO RECEIVING MORTAR BED/BOND COAT AND WALL TILES. 36. ALL WALL TILES ARE TO HAVE A MORTAR BED/BOND COAT THICKNESS TO ACCOMMODATE THE VARYING THICKNESSES OF ALL MATERIAL TYPES OF TILE SPECIFIED FOR WALL INSTALLATION WITH A FLUSH FRONT FACE. 37. ALL TRANSLUCENT GLASS TILE SPECIFIED ARE TO RECEIVE UNIFORM COVERAGE BY BACK BUTTERING TILES AND TROWEL RIDGES FLATTENED PRIOR TO SETTING. 38. FLOORS OF TOILETS, BATHING AND SHOWER ROOMS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE. THE INTERSECTION OF SUCH FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, NONABSORBENT VERTICAL BASE AS SPECIFIED IN FINISH PLANS OR RESTROOM ELEVATIONS. BASE SHALL EXTEND UPWARD ONTO THE WALLS NOT LESS THAN 4 INCHES. 39. WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE FLOOR. DEMOLITION NOTES 1. DRAWINGS OF EXISTING CONDITIONS HAVE BEEN COMPILED FROM EXISTING DATA SUPPLIED BY THE OWNER TO THE ARCHITECT. THE ARCHITECT MAKES NO WARRANTY, EITHER EXPRESSED NOR IMPLIED, FOR THE ACCURACY OR THE COMPLETENESS OF THE EXISTING INFORMATION RECORDED. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE IN THE COURSE OF THE DEMOLITION WORK. 2. PROTECT AND VERIFY LOCATIONS OF EXISTING MECHANICAL, PLUMBING AND ELECTRICAL UTILITIES SCHEDULED TO REMAIN. WHERE DEMOLITION IS INDICATED, DISCONNECT AND REMOVE BACK TO NEAREST JUNCTION BOX OR PANEL, TERMINATE AND CAP DESIGNATED UTILITIES WITHIN THE DEMOLITION AREA. REFER TO THE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFO. 3. ALL EXISTING BUILDING UTILITIES SHALL REMAIN IN OPERATION DURING DEMOLITION AND CONSTRUCTION. REROUTE UTILITIES SERVING ADJACENT AREAS AS REQUIRED TO MAINTAIN UNINTERRUPTED SERVICE. ANY TEMPORARY INTERRUPTION OF SERVICE SHALL BE COORDINATED AND APPROVED BY THE FACILITY MANAGER, NOT LESS THAN 72-HOURS IN ADVANCE. 4. THE DEMOLITION PLAN KEYNOTES ARE DIAGRAMMATIC AND GENERAL IN NATURE. THEIR INTENT IS TO ILLUSTRATE THE COMPLETE DEMOLITION AND REMOVAL OF NON- STRUCTURAL ELEMENTS WITHIN THE SPACES INDICATED UNLESS NOTED OTHERWISE. FIELD VERIFICATION OF EXISTING CONDITIONS AND SPECIFIC QUANTITIES IS THE RESPONSIBILITY OF THE CONTRACTOR. 5. REMOVAL AND DISPOSAL OF DEMOLITION DEBRIS IS THE RESPONSIBILITY OF THE CONTRACTOR. VERIFY THE HAULING ROUTE THROUGH THE BUILDING, THE DEMOLITION STAGING AREA, AND THE LOCATION OF THE DUMPSTERS WITH THE OWNER PRIOR TO THE START OF DEMOLITION. DISPOSAL OF RUBBISH SHALL BE DONE IN A LEGAL MANNER. 6. THE OWNER RESERVES THE RIGHT TO SALVAGE ANY DEMOLISHED ITEM. CONTRACTOR TO VERIFY ITEMS TO BE SALVAGED FOR THE OWNER’S PURPOSE WITH THE OWNER PRIOR TO THE START OF DEMOLITION. REMOVE, PROTECT, CLEAN, AND REPAIR SALVAGED ITEMS AS REQUIRED FOR REUSE AND TURN OVER SUCH ITEMS AS DIRECTED BY THE OWNER. 7. INSTALLATION OF NEW WORK INCLUDING, BUT NOT LIMITED TO MECHANICAL, PLUMBING OR ELECTRICAL, MAY REQUIRE THE CONTRACTOR AND HIS SUBCONTRACTORS TO REMOVE AND REPLACE OR RE-FINISH EXISTING WALLS, FLOORS, OR CEILING TO MATCH EXISTING IN THE AREAS OF THE BUILDING NOT SHOWN ON THESE PLANS. THE CONTRACTOR SHALL INCLUDE ALL RELATED COSTS IN HIS BASE BID, WHETHER OR NOT THIS WORK IS SHOWN ON THESE PLANS. 8. AT ADJACENT SPACES NOT SCHEDULED FOR DEMOLITION, PATCH AND REPAIR DAMAGED FINISHES AND ITEMS AND FIXTURES TO REMAIN AND/OR REPLACE IN KIND TO MATCH EXISTING FROM DAMAGE DURING THE PROGRESS OF THE WORK. 9. PROVIDE TEMPORARY SAFETY BARRIERS REQUIRED BY CODE AND AS INDICATED TO INSURE PUBLIC SAFETY AND TO ALLOW EXISTING BUILDING OCCUPANCY. CONTRACTOR TO SUBMIT FOR OWNER APPROVAL, BARRIER LOCATIONS AND METHOD OF CONSTRUCTION PRIOR TO INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY REQUIRED BUILDING DEPARTMENT APPROVAL. 10. PROVIDE AND INSTALL DUST BARRIERS AT ALL OPENINGS FROM ADJACENT INTERIOR SPACES TO THE CONSTRUCTION AREA. PROVIDE ALL MEANS NECESSARY TO INHIBIT DUST FROM ENTERING OTHER PORTIONS OF THE FACILITY. SUBMIT PROPOSED BARRIER LOCATIONS TO THE OWNER AND THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO THE START OF DEMOLITION AND CONSTRUCTION. 11. PROVIDE ADEQUATE SHORING, BRACING, BARRICADES AND PROTECTIVE MEASURES AS REQUIRED TO SAFELY EXECUTE THE WORK IN THE CONSTRUCTION AREA AND THE AREAS ADJACENT TO THE CONSTRUCTION AREA. CEASE OPERATIONS AND NOTIFY THE ARCHITECT IMMEDIATELY IF THE STRUCTURE APPEARS TO BE ENDANGERED. DO NOT RESUME OPERATIONS UNTIL CORRECTIVE MEASURES HAVE BEEN TAKEN. 12. PROVIDE TEMPORARY NON-COMBUSTIBLE CONSTRUCTION BARRIERS WHERE REQUIRED BY CODE AND THE GOVERNING FIRE AUTHORITY. AT A MINIMUM THE BARRIERS SHALL: A. BE FULL HEIGHT WALL FROM FLOOR TO CEILING. B. BE STUDS AT 24" O.C., WITH 5/8" TYPE 'X' GYPSUM BOARD. C. INCLUDE NON-COMBUSTIBLE ACCESS DOOR WITH (3) HINGES AND SPRING CLOSER. 13. CUT RIGID MATERIALS USING MASONRY SAW OR CORE DRILL. PNEUMATIC TOOLS ARE NOT ALLOWED WITHOUT PRIOR APPROVAL OF THE OWNER. 14. CONTRACTOR IS RESPONSIBLE FOR BUILDING SECURITY DURING DEMOLITION PHASE. PROTECT ALL OPENINGS FROM WEATHER CONDITIONS AND SECURE THEM TO PREVENT VANDALISM. 15. DO NOT PERFORM ANY WORK THAT COULD VOID WARRANTIES OF EXISTING WEATHER EXPOSED OR MOISTURE RESISTANT ELEMENTS WITHOUT PRIOR APPROVAL FROM THE OWNER. 16. THE ARCHITECT ASSUMES NO RESPONSIBILITY RELATING TO ANY TOXIC MATERIALS, INCLUDING ASBESTOS, AND ASSUMES NO RESPONSIBILITY TO ITS EXISTENCE OR REMOVAL. THE OWNER IS SOLELY RESPONSIBLE FOR CONTRACTING WITH A CONSULTANT OR SPECIALIST, LICENSED BY THE STATE, FOR SUCH SERVICES SHOULD THOSE SERVICES BE REQUIRED ON THE PROJECT. 17. IF THE EXISTING BUILDING CONSTRUCTION IS CLASSIFIED SUCH THAT FIREPROOFING INSULATION IS PRESENT, THEN THE CONTRACTOR, PRIOR TO STARTING ANY WORK, SHALL VERIFY THE CURRENT FIRE-RESISTANCE RATING(S) OF THE EXISTING BUILDING ELEMENT(S). IF THE EXISTING FIREPROOFING INSULATION IS DAMAGED/AFFECTED DURING THE COURSE OF THE WORK, AS DEFINED BY THIS PROJECT SCOPE, THEN THE CONTRACTOR SHALL PATCH/REPAIR THE FIREPROOFING INSULATION TO A CONDITION THAT SHALL MATCH OR EXCEED THE ORIGINAL FIRE-RESISTANCE RATING(S) OF THE EXISTING BUILDING ELEMENT(S). 18. EXISTING DOORS TO REMAIN, U.O.N. 19. STRUCTURAL ENGINEER TO REVIEW AND APPROVE THE LOCATION AND SIZE OF CORED AND CUT OPENINGS IN ELEVATED DECKS AS WELL AS THE MAXIMUM PENETRATION DEPTH OF DRILLED OR SHOT-ON ANCHORS AND OTHER FASTENERS. . . GENERAL PROJECT NOTES 1. ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL, INDUSTRY AND PROJECT-SPECIFIC REQUIREMENTS AND STANDARDS INCLUDING WITHOUT LIMITATION OF THE FOLLOWING: A. ALL APPLICABLE BUILDING CODES B. ALL APPLICABLE SPECIALTY CODES INCLUDING THE MOST CURRENT ISSUES AND SUPPLEMENTS C. THE PROJECT MANUAL AND ASSOCIATED SPECIFICATIONS WHEN PROVIDED D. THE MANUFACTURER'S REQUIREMENTS OR RECOMMENDATIONS E. ALL APPLICABLE LANDLORD BUILDING STANDARDS 2. IN USING THESE PLANS FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES OR IN DOCUMENTS PROVIDED BY OTHER MEMBERS OF THE PROJECT DESIGN TEAM. UNLESS EXPRESSLY PROVIDED OTHERWISE, THE INTENT IS TO INCLUDE ALL LABOR, MATERIALS, PRODUCTS AND SERVICES NECESSARY OR APPROPRIATE FOR THE COMPLETED PROJECT AS CALLED FOR OR REASONABLY IMPLIED FROM THE PLANS AND SPECIFICATIONS PROVIDED BY THE PROJECT'S DESIGN TEAM. IN CASE OF CONFLICTS OR OMISSIONS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT OR COSTLY STANDARD. 3. IN INTERPRETING THESE PLANS, THE FOLLOWING GENERAL RULES APPLY: A. WRITTEN DIMENSIONS SHALL GOVERN. DO NOT SCALE THE DRAWINGS. LARGE SCALE DRAWINGS AND DETAILS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS B. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS C. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK IN THE SAME BUILDING. D. WORK SHOWN AS "NIC" IS FOR REFERENCE ONLY AND THE RESPONSIBILITY OF THE CONTRACTOR ONLY TO THE EXTENT THAT THIS WORK MAY REQUIRE SOME REASONABLE PROTECTION OR COORDINATION EFFORTS. 4. THESE PLANS AND SPECIFICATIONS ARE INTENDED TO REPRESENT ONLY THE FINISHED CONSTRUCTION. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION AND DEMOLITION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES INCLUDING ANY AND ALL SAFETY PRECAUTIONS AND PROGRAMS, AND SHALL INDEMNIFY TO THE FULLEST EXTENT ALLOWED BY LAW THE OWNER AND THE PROJECT DESIGN TEAM FROM AND AGAINST ANY AND ALL RELATED CLAIMS AND LIABILITY. 5. THESE PLANS AND SPECIFICATIONS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR INFORMATION (RFIs). ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF AN APPROPRIATE OWNER REPRESENTATIVE IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. 6. DIMENSIONS SCALED FROM DRAWINGS SHALL BE CONSIDERED APPROXIMATE. CONTRACTORS THAT FAIL TO FIELD MEASURE AND VERIFY DISTANCES, CLEARANCE AND FIT ARE PROCEEDING AT THEIR OWN RISK. 7. EXCEPT WHERE DIMENSIONED, PLANS ARE TO BE CONSIDERED DIAGRAMMATIC IN NATURE AND INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS. 8. DESIGN/BUILD CONTRACTOR SUBMITTALS WILL BE REVIEWED BY THE PROJECT DESIGN TEAM, IF AT ALL, ONLY FOR CONFORMANCE WITH THE AESTHETIC ASPECTS AND MAJOR SPACE LIMITATIONS OF THE PROJECT; AND EACH DESIGN/BUILD CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING: A. PREPARING ALL THE ENGINEERING AND OTHER DRAWINGS AND SPECIFICATIONS FOR THE COMPONENTS OF ITS DESIGN/BUILD UNDERTAKING. B. COMPLYING WITH THE PROJECT'S REQUIREMENTS AND SPACE LIMITATIONS. C. COORDINATION AND INTERFACING WITH OTHER TRADES AND CONSULTANTS. D. OBTAINING ANY REQUIRED OR APPROPRIATE APPROVALS FROM AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. E. HAVING THEIR DESIGN CONSULTANTS SERVE AS THE PROFESSIONAL OF RECORD FOR THE PORTIONS OF WORK WHICH THEY DESIGN. 9. AS MAY BE REQUIRED BY THE AUTHORITIES HAVING JURISDICTION, AT THE CONCLUSION OF CONSTRUCTION EACH PRIME CONTRACTOR SHALL PROVIDE WRITTEN CERTIFICATION THAT THEIR PORTION OF THE WORK HAS BEEN PERFORMED IN COMPLIANCE WITH THE BUILDING PERMIT APPROVED PLANS AND SPECIFICATIONS. 10. VERSIONS OF THESE PLANS PROVIDED IN ANY ELECTRONIC FORM ARE SUBJECT TO THE SAME PROVISION AS THE OTHER INSTRUMENTS OF SERVICE PREPARED BY OR ON BEHALF OF THE PROJECT DESIGN TEAM, INCLUDING WITHOUT LIMITATION THEIR COMMON LAW, STATUTORY OR OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS. A RECIPIENT IS GRANTED AT MOST A TRANSFERABLE NONEXCLUSIVE LICENSE TO REUSE THE PLANS SOLELY FOR PROJECT PURPOSES; AND NO RECIPIENT IS AUTHORIZED TO USE OR TO ALLOW THE USE OF ALL OR ANY PORTION OF THESE PLANS FOR ANY OTHER PURPOSE, AND ANY OTHER USE FOR ANY OTHER PURPOSE COULD CONSTITUTE ACTIONABLE PLAGIARISM. ANY ELECTRONIC DOCUMENTS WILL BE PROVIDED IN THE RESPONSIBLE DESIGN PROFESSIONAL'S STANDARD FORMATS AND CONVENTIONS AND WITH NO GUARANTEE OF THE ABSENCE OF VIRUSES OR OTHER HARMFUL MATERIAL, OR OF COMPATIBILITY WITH ANY RECIPIENT'S SOFTWARE OR HARDWARE SO THAT ANY USE WITH OR CONVERSION TO THE OTHER FORMS OR CONVENTIONS, OR THE USE WITH ANY PARTICULAR SOFTWARE OR HARDWARE, IS AT THE RECIPIENT'S SOLE RISK. 1. WHERE EXISTING TENANTS/BUSINESSES ARE ADJACENT TO THE JOB SITE/TENANT, THE CONTRACTOR SHALL MINIMIZE CONSTRUCTION NOISE - EXTREMELY NOISY CONSTRUCTION SHALL OCCUR AT NON-TYPICAL BUSINESS HOURS. CONTRACTOR SHOULD NOTIFY BUILDING REPRESENTATIVE OF SPECIAL CIRCUMSTANCES IN ADVANCE PRIOR TO WORK. 2. THE CONTRACTOR AT HIS OWN EXPENSE, SHALL KEEP THE PROJECT AND SURROUNDING AREA FREE FROM DUST AND DEBRIS. THE WORK SHALL BE IN CONFORMANCE WITH THE AIR AND WATER POLLUTION CONTROL STANDARDS AND REGULATIONS OF THE STATE DEPARTMENT OF HEALTH. 3. CONSTRUCTION DEBRIS AND WASTES SHALL BE DEPOSITED AT AN APPROPRIATE SITE. THE CONTRACTOR SHALL INFORM THE BUILDING REPRESENTATIVE OF THE LOCATION OF DISPOSAL SITES. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL CLEANING OF THE JOB AFTER ITS COMPLETION. WHERE APPLICABLE, CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO, THE EXTERIOR AND THE INTERIOR OF THE BUILDING, THE PATH OF TRAVEL TO THE JOB SITE, PARKING LOTS, ELEVATORS, LOBBIES, AND CORRIDOR CARPETS. 5. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION, WHERE REQUIRED PER STATE AND LOCAL CODES. 6. IF TRENCHES OR EXCAVATIONS 5'-0" OR MORE IN DEPTH ARE REQUIRED, OBTAIN ISSUANCE OF A BUILDING OR GRADING PERMIT. 7. NO HAZARDOUS MATERIALS SHALL BE USED OR STORED WITHIN THE BUILDING WHICH DOES NOT COMPLY WITH THE LOCAL FIRE AUTHORITY AND STATE & COUNTY REQUIREMENTS. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR BLOCKING OFF SUPPLY AND RETURN AIR GRILLES, DIFFUSERS & DUCTS TO KEEP DUST FROM ENTERING INTO BUILDING AIR DISTRIBUTION SYSTEMS. 9. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED. 1. UNLESS OTHERWISE NOTED OR INDICATED, ALL DIMENSIONS ON THESE DOCUMENTS SHALL BE TO FACE OF CURB, FACE OF CONCRETE OR MASONRY, FACE OF FINISH OR CENTERLINE OF GRIDS. 2. ALL VERTICAL DIMENSIONS SHOWN ARE FROM FLOOR SLAB, U.O.N. 3. THE TERM "ALIGN", AS USED IN THESE DOCUMENTS, SHALL MEAN TO ACCURATELY LOCATE FINISHES IN THE SAME PLANE. 4. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS THROUGHOUT, U.O.N. 5. DETAILS ARE USUALLY KEYED AND NOTED "TYPICAL" ONLY ONCE, WHEN THEY FIRST OCCUR AND ARE REPRESENTATIVE OF ALL SIMILAR CONDITIONS THROUGHOUT, U.O.N. 6. COLUMN CENTERLINES (GRID LINES) ARE SHOWN FOR DIMENSIONING PURPOSES. 1. WHERE ELECTRICAL, MECHANICAL AND/OR PLUMBING ITEMS, SUCH AS LIGHTS, DUCTS, PIPING, DOWNSPOUTS, ETC. ARE TO PENETRATE ANY BUILDING FOOTINGS, SLABS, FLOORS, STRUCTURAL FRAMING, WALL PARTITIONS, CEILINGS, ETC., IT IS REQUIRED THAT AN APPROPRIATELY SIZED OPENING OR CLEARANCE BE FURNISHED. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL ITEMS WITH THE CONSTRUCTION DOCUMENTS PRIOR TO THE INSTALLATION OF STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WORK. ANY CONFLICT OR DISCREPANCY WITHIN CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION. 2. CONTRACTORSHALL PROVIDE AND LOCATE ACCESS DOORS/PANELS IN WALL & CEILING CONSTRUCTION AS REQUIRED TO PROVIDE ACCESS TO MECHANICAL, FIRE SPRINKLER, PLUMBING & ELECTRICAL WORK. CONTRACTOR SHALL SUBMIT A PLAN OF ALL PROPOSED ACCESS PANEL LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 3. ALL PENETRATIONS AT RATED CONSTRUCTION SHALL BE PROTECTED TO MAINTAIN RATING. 4. THE CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGE TO EXISTING CONSTRUCTION DUE TO WORK PERFORMED. THE CONTRACTOR SHALL FURNISH AND INSTALL NEW MATERIALS AT NO ADDITIONAL COST TO THE OWNER TO REPAIR SUCH DAMAGE. 5. INTERIOR WALLS AND CEILINGS SHALL BE INSTALLED IN ACCORDANCE WITH STATE & LOCAL CODES, INCLUDING REQUIREMENTS FOR FLAME SPREAD AND SMOKE DENSITY RATINGS FOR FINISH MATERIALS. 6. WHEN USED, ALL NOISE BARRIER BATTS (SOUND INSULATION) AND INSULATION BATTS SHALL BE NON-COMBUSTIBLE AND SHALL NOT CONTAIN OR UTILIZE OZONE DEPLETING COMPOUNDS. JOB SITE NOTES DRAWING INTERPRETATION –GENERAL RULES INTERIOR/EXTERIOR NOTES GENERAL NOTES DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 (A) WHEELCHAIR ACCESSIBLE WATER CLOSETS (B) AMBULATORY ACCESSIBLE WATER CLOSETS SIZE OF CLEARANCE AT WATER CLOSETS TRANSFER SIDE SIDE WALL GRAB BAR AT WATER CLOSETS REAR WALL GRAB BAR AT WATER CLOSETS (B) STALL TYPE (A) WALL HUNG TYPE HEIGHT AND DEPTH OF URINALS AMBULATORY ACCESSIBLE TOILET COMPARTMENT WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCES (A) ELEVATION ADULT (B) ELEVATION CHILDREN (C) PLAN PARTITION PARTITION CLEARANCE DOOR PERMITTED TO SWING OVER HATCHED PORTION OF MANEUVERING SPACE ALTERNATE DOOR LOCATION WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS CLEARANCE CLEARANCE DISPENSERS AND DISPOSAL UNITS DOOR PERMITTED TO SWING OVER HATCHED PORTION OF MANEUVERING SPACE CLEARANCE CLEARANCE DOOR PERMITTED TO SWING OVER HATCHED PORTION OF MANEUVERING SPACEMANEUVERING SPACE WITH SIDE-OPENING DOOR MANEUVERING SPACE WITH END-OPENING DOOR WATER CLOSET LOCATION @ SIDE DOOR MANEUVERING SPACE MANEUVERING SPACE 17"-18".17"-19". 56 " M I N . 48 " M I N . MIN. 13 1/2" MA X . 1 7 " 13 1/2" MIN. MIN. 54" MIN. 42" 12" MAX. 24" MIN. 12" MIN. 36" MIN. MAX. 4" MA X . 4" . 60 " M I N . * 60" MIN. 60 " M I N . * 60" MIN. 7"-9". 1 9 " . 60 " M I N . * MANEUVERING SPACE 48" MIN. 60 " M I N . * MANEUVERING SPACE 48" MIN. 60 " M I N . 35"-37". 44 " M I N . MIN. 6" MI N . 9" MIN. 6" MI N . 1 2 " MIN. 6" MI N . 6" 60" MIN. CLOSET 59" MIN. @ FLOOR MOUNTED WATER CLOSET 56" MIN. @ WALL MOUNTED WATER CLOSET 56" MIN. @ WALL MOUNTED WATER CLOSET 59" MIN. @ FLOOR MOUNTED WATER SWINGS IN 36" MIN. WHEN DOOR CLOSET 59" MIN. @ FLOOR MOUNTED WATER CLOSET 56" MIN. @ WALL MOUNTED WATER CLOSET 56" MIN. @ WALL MOUNTED WATER CLOSET 59" MIN. @ FLOOR MOUNTED WATER SWINGS IN 36" MIN. WHEN DOOR 1 7 " - 1 9 " 33 " - 3 6 " 33 " - 3 6 " 34" MIN. 4" MAX.34" MIN. 4" MAX. TOILET COMPARTMENT DOORS SHALL BE SELF-CLOSING. A DOOR PULL SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. 24" MIN. SANITARY NAPKIN DISPOSAL UNIT (OPENING) TOILET PAPER DISPENSER * 60" MIN. @ TOILET PARTITION 66" MIN. @ FULL FT. WALL (A)(B) (C) DOORS IN SERIES AND GATES IN SERIES 48" MIN. 48" MIN.48" MIN. (B)(A) LIMITS OF PROTRUDING OBJECTS POST MOUNTED PROTRUDING OBJECTS VERTICAL CLEARANCE EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4 1/2 INCHES (115 MM) MAXIMUM. X > 2 7 " . X > 8 0 " . 27 " - 8 0 " . 4" MAX. MAX. 12"MAX. 12" 27 " M A X . 80 " M I N . X > 12" X > 12" X > 8 0 " MA X . 27 " POLE VERTICAL GUY BRACE 80 " M I N . GUY BRACES (A) (B) (A) (B) UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH OBSTRUCTED HIGH SIDE REACH UNOBSTRUCTED HIGH SIDE REACH 1 5 " M I N . 48 " M A X . 20" MAX. 48 " M A X . 44 " M A X . >20"-25" MAX. 48 " M A X . MI N . 1 5 " 10" MAX. 10" MAX. 48 " M A X . 34 " M A X . MA X . 34 " MA X . 46 " 24" MAX. >10"- (A) ELEVATION (ENLARGED) (B) PLAN SIZE AND SPACING OF TRUNCATED DOMES 2. 3 " - 2 . 4 " . 2.3" - 2.4". 0. 6 5 " MI N . 0 . 2 " 0.9" - 0.92" BASE ø 0.45" - 0.47" TOP ø (A) 180 DEGREE TURN (B) 180 DEGREE TURN (EXCEPTION) CLEAR WIDTH OF AN ACCESSIBLE ROUTE CLEAR WIDTH AT TURN 48 " M I N . MIN. 42" X < 48" MIN. 42" MIN. 36" MIN. 36" X < 48" 60 " M I N . MI N . 32 " 36 " M I N . MAX. 24" MIN. 48" MAX. 24" 36 " M I N . MI N . 32 " (A) ELEVATION (B) PLAN (A) ELEVATION (B) PLAN TOE CLEARANCE KNEE CLEARANCE (C) ELEVATION @ LAVATORY 9" M I N . MAX. 6"17"-25" MI N . 30 " MIN. 8" MI N . 27 " . 9" M I N . MIN. 11"25" MAX. MI N . 30 " 9" M I N . MIN. 11" MI N . 27 " . 29 " M I N . MIN. 8" POSITION OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR CHILDREN'S USE, GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION 18 INCHES MINIMUM AND 27 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. (A) PROJECTING OBJECTS (B) RECESSED OBJECTS SPACING. THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 1-1/2 INCHES MINIMUM. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES MINIMUM. CIRCULAR CROSS SECTION. GRAB BARS WITH CIRCULAR CROSS SECTIONS SHALL HAVE AN OUTSIDE DIAMETER OF 1-1/4 INCHES MINIMUM AND 2 INCHES MAXIMUM. SPACING OF GRAB BARS 4"-4.8" (A) (B) GRAB BAR NON-CIRCULAR CROSS SECTION 1 2 " M I N . 1 - 1 / 2 " M I N . 1-1/2". 2" MAX.2" MAX. PERIMETER BACKING. PROVIDE MIN. 6 INCHES x 16 GA CONTINUOUS SHEET METAL BACKING ATTACHED TO MIN. 3 STUD BAYS WITH #10 FLAT HEAD SHEET METAL SCREWS. INSTALL GRAB BARS PER MANUFACTURER'S REQUIREMENTS.DOMINANT DIRECTION OF TRAVEL ELONGATED OPENINGS IN FLOOR OR GROUND SPACE CARPET PILE HEIGHT VERTICAL CHANGE IN LEVEL BEVELED CHANGE IN LEVEL 2 1 NOTES: 1. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. 2. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL COMPLY WITH CARPET PILE HEIGHT FIGURE BELOW. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE SHALL COMPLY WITH CHANGE IN LEVEL FIGURES BELOW. 1 / 4 " 1 / 4 " 1 / 2 " MA X . 1 / 4 " . 1 / 4 " . 1 / 4 " M A X . 1/2" MAX. 1 / 2 " MA X . . LONG DIMENSION PERPENDICULAR TO DOMINANT DIRECTION OF TRAVEL EQUIPMENT PERMITTED IN SHADED AREA FRONT & SIDE APPROACH INSULATE EXPOSED PIPES AND SURFACES SPOUT OUTLETSPOUT OUTLET MIRROR @ LOCKER ROOMS WHEELCHAIRACCESSIBLE DRINKINGFOUNTAIN MIRROR NOT OVER A LAVATORY FIXED TABLE OR COUNTER STANDING DRINKING FOUNTAIN URINAL LAVATORY ACCESSORIES MIRROR @ LAVATORY 18"-19" 15" MIN. 5" MAX. 9" M I N . MAX. 6" MIN. 8" MI N . 27 " . 36 " M A X . 38 " - 4 3 " 9" M I N . MAX. 6" MIN. 8" 27 " MI N . 29 " M I N 34 " MA X . 17" MIN 24" MAX 15" MIN APPROACH 30" CLR FORWARD 13-1/2" MIN. 1 7 " M A X . 44 " MA X . 34 " M A X . 18" MIN. 40 " M A X . 6' - 2 " M I N . 35 " M A X . 6' - 2 " M I N . 18" MIN 20 " MA X . 54 " M I N . 40 " M A X . 19" MIN. 27 " MI N . 28 " - 3 4 " (*) OPERABLE PART LOCATED WITHIN 6" OF FRONT EDGE OF THE FOUNTAIN (*) (A) FRONT APPROACH, PULL SIDE (*) IF BOTH CLOSER AND LATCH ARE PROVIDED (E) HINGE APPROACH, PULL SIDE (F) (G*) HINGE APPROACH, PUSH SIDE (H) LATCH APPROACH, PULL SIDE (J) (K*) LATCH APPROACH, PUSH SIDE (B) (C*) FRONT APPROACH, PUSH SIDE (*) 48" MIN. IF CLOSER IS PROVIDED. MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES (A) PULL SIDE MANEUVERING CLEARANCE AT RECESSED DOORS AND GATES (B) PUSH SIDE (C) PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH (A) HINGED DOOR (B) SLIDING DOOR (C) FOLDING DOOR CLEAR WIDTH OF DOORWAYS (*) 48" MIN. IF BOTH CLOSER AND LATCH PROVIDED. NOTES: 1. FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL COMPLY WITH [FLOOR OR GROUND SURFACES & CHANGES IN LEVEL] DETAIL AND SHALL HAVE A SLOPE NOT STEEPER THAN 1:48. CHANGES IN LEVEL ARE NOT PERMITTED AT DOOR LANDINGS. 2. THRESHOLDS, IF PROVIDED AT DOORWAYS SHALL BE 1/2" HIGH MAX. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH [FLOOR OR GROUND SURFACES & CHANGES IN LEVEL] DETAIL. 3. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OR THE WRIST. 4. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 LBS (22.5 N) MAX. 5. OPERABLE PARTS OF DOOR HARDWARE SHALL BE 34" MIN. AND 44" MAX. ABOVE THE FINISH FLOOR OR GROUND. 6. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. 7. DOOR AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90° THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12° FROM THE LATCH IS 5 SECONDS MIN. 8. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70° THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MIN. 9. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE AS FOLLOWS: 9.1. INTERIOR HINGED DOORS AND GATES: 5 LBS (22.5 N) MAX. 9.2. SLIDING OR FOLDING DOORS: 5 LBS (22.5 N) MAX. 9.3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS (66.7N). 9.4. EXTERIOR HINGED DOORS: 5 LBS (22.5 N) MAX. 10. SWINGING DOOR AND GATE SURFACES WITHIN 10" OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACE SHALL BE WITHIN 1/16" OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. 11. WHERE AUTOMATIC AND POWER-ASSISTED DOORS AND GATES WITHOUT STANDBY POWER ARE PART OF A MEANS OF EGRESS THE CLEAR BREAK OUT OPENING AT SWINGING OR SLIDING DOORS AND GATES SHALL BE 32" MIN. WHEN OPERATED IN EMERGENCY MODE. 32" MIN. 32" MIN. 32" MIN. 60 " M I N . DOOR 18" MIN @ INTERIOR 12" MIN. * 48 " M I N 60 " M I N . 36" MIN. 44 " M I N . * 22" MIN. 60 " M I N . 24" MIN.24" MIN. 44 " M I N . * 60 " M I N 18" MIN. @ INTERIOR 48 " M I N 48 " M I N 12" MIN X > 8 " . X > 8 " . X > 8 " . 90.00° 24" MIN. @ EXTERIOR EXTERIOR DOOR 24" MIN. @ EXTERIOR SIDE OF 0.300".0.100". 0. 1 0 0 " . 0. 4 0 0 " M A X . 0. 3 9 5 " M I N . SINGLE BRAILLE CELL BLANK CELL SPACE BETWEEN WORDS RAISED DOT NO RAISED DOT 0.059" MIN. TO 0.063" MAX. DOT HEIGHT 0.025" MIN. TO 0.037" MAX. MEASURED CENTER TO CENTER. HEIGHT OF RAISED CHARACTERS POSITION OF BRAILLE HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND CENTERED ON TACTILE CHARACTERS LOCATION OF TACTILE SIGNS AT DOORS PICTOGRAM FIELD NOT IN PICTOGRAM FIELD INTERNATIONAL SYMBOL OF ACCESSIBILITY MEN AREA OF REFUGE AREA OF REFUGE AREA OF REFUGELIBRARY 5/ 8 " - 2 " 3/ 8 " - 1 / 2 " MI N . 3/ 8 " . 60 " M A X . 48 " M I N . 6" M I N . MI N . 1 8 " MIN. 18" 45 ° INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS DOOR ELEVATION UNISEX MEN'SWOMEN'S WOMEN'S & MEN'S SIGNAGE 1/4" THICK SOLID SURFACE DOOR- MOUNTED SIGNAGE TO BE LOCATED IN CENTER OF DOOR. TRIANGLE SYMBOL AND CIRCLE SYMBOL SHALL CONTRAST WITH DOOR. UNISEX SIGNAGE 1/4" THICK SOLID TRIANGLE SUPERIMPOSED ON THE 1/4" THICK SOLID CIRCLE SURFACE. TRIANGLE SYMBOL SHALL CONTRAST WITH CIRCLE SYMBOL. CIRCLE SYMBOL SHALL CONTRAST WITH DOOR. DOOR SIGNAGE EDGES OF SIGNS SHALL BE ROUNDED, CHAMFERED OR EASED. CORNERS OF SIGNS SHALL HAVE A MINIMUM RADIUS OF 1/8" 12"ø 10". OF S I G N MO U N T 6 0 " A F F TO C E N T E R L I N E EQ. EQ. 12 " ALL SIDES EXIT CORRESPONDING (GRADE 2) BRAILLE PER LOCAL ACCESSIBILITY STANDARDS SANS-SERIF UPPERCASE CHARACTERS, RAISED 1/32" PER LOCAL APPLICABLE ACCESSIBILITY STANDARDS CHARACTERS & BACKGROUND OF SIGNS TO BE NON-GLARE FINISH AND TO CONTRAST WITH EACH OTHER. (MATCH EXISTING COLORWAY). COLOR & CONTRAST OF SIGN TO BE DISTINCTLY DIFFERENT THAN COLOR & CONTRAST OF WALL EXIT ROUTE * 135% MIN. AND 170% MAX. OF CHARACTER HEIGHT CORRESPONDING (GRADE 2) BRAILLE PER LOCAL ACCESSIBILITY STANDARDS SANS-SERIF UPPERCASE CHARACTERS, RAISED 1/32" PER LOCAL APPLICABLE ACCESSIBILITY STANDARDS CHARACTERS & BACKGROUND OF SIGNS TO BE NON-GLARE FINISH AND TO CONTRAST WITH EACH OTHER. (STANDARD COLOR: WHITE ON BLACK BACKGROUND, UNLESS APPROVED OTHERWISE). COLOR & CONTRAST OF SIGN TO BE DISTINCTLY DIFFERENT THAN COLOR & CONTRAST OF WALL ACCESSIBILITY NOTES SCALE: 1/4" = 1'-0" 4 WATER CLOSETS AND TOILET COMPARTMENTS & URINALS SCALE: 1/4" = 1'-0" 6DOORS, DOORWAYS & GATES SCALE: 1/4" = 1'-0" 11PROTRUDING OBJECTS SCALE: 1/4" = 1'-0" 12 REACH RANGES N.T.S.14DETECTABLE WARNINGS SCALE: 1/4" = 1'-0"17CLEAR WIDTH SCALE: 1/4" = 1'-0" 16KNEE AND TOE CLEARANCE 1. "THE ACCESSIBILITY GUIDELINES AND CODES" MENTIONED BELOW REFER TO ALL APPLICABLE LOCAL/STATE BUILDING CODES REFERENCED ON THE PROJECT DATA SHEET OF THIS SET IN ADDITION TO THE FEDERAL REQUIREMENTS OF THE ADA (THE AMERICANS WITH DISABILITIES ACT). 2. DETAILS ON THIS SHEET ARE FOR REFERENCE ONLY, REFER TO THE ACCESSIBILITY GUIDELINES AND CODES FOR ALL ACCESSIBILITY REQUIREMENTS. 3. THE GENERAL CONTRACTOR SHALL BECOME FAMILIAR WITH THE ACCESSIBILITY GUIDELINES AND CODES. 4. ANY DISCREPANCY CONTAINED HEREIN DOES NOT RELIEVE THE GENERAL CONTRACTOR OR OWNER FROM COMPLYING WITH THE ACCESSIBILITY GUIDELINES AND CODES. SCALE: 1/4" = 1'-0"5GRAB BARS SCALE: 1/2" = 1'-0"15 FLOOR OR GROUND SURFACES & CHANGES IN LEVEL SCALE: 1/4" = 1'-0" 13MOUNTING HEIGHTS SCALE: 1/4" = 1'-0" 10DOORS, DOORWAYS & GATES SCALE: 3/8" = 1'-0"18BRAILLE MEASUREMENT SCALE: 1/4" = 1'-0"20 SIGNS SCALE: 12" = 1'-0"22RESTROOM SIGNAGE, TYP. SCALE: 3" = 1'-0"21TACTILE "EXIT" SIGN 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 4 4 P M K. BURGER CB / JG SDG22-6057-00 AC C E S S I B I L I T Y D E T A I L S I0.3 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L SCALE: 3" = 1'-0" 23TACTILE "EXIT ROUTE" SIGN 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 2500 RED HILL AVE. SANTA ANA, CA 92705 DENOTES BUILDING OF AREA OF TENANT IMPROVEMENT TYP. 006 007 001 002 TYP. 003 001 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 4 5 P M K. BURGER CB / JG SDG22-6057-00 SI T E P L A N ( F o r R e f e r e n c e O n l y ) I0.4 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 SEE SHEETS I0.1 -I0.2FOR GENERAL NOTES KEYNOTES: SCALE: 1/16" = 1'-0" 1SITE PLAN (FOR REFERENCE ONLY) DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 001 EXISTING FULLY ACCESSIBLE PRIMARY ENTRY TO REMAIN. 002 HEAVY DASHED LINE INDICATES EXISTING FULLY ACCESSIBLE PATH OF TRAVEL TO REMAIN. 003 ALL PARKING IS EXISTING TO REMAIN NO CHANGES PROPOSED. 006 EXISTING FULLY ACCESSIBLE PARKING STALL AND SIGNAGE TO REMAIN. 007 EXISTING STRIPING TO REMAIN. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE GROUND WITHIN EACH 5'-0" / 8'-0" (AT VAN SPACE) LOADING AND UNLOADING ACCESS AISLE. THIS NOTICE SHALL BE PAINTED IN WHITE LETTERS NO LESS THAN 12 INCHES HIGH AND LOCATED SO THAT IT IS VISIBLE TO TRAFFIC ENFORCEMENT OFFICIALS. CBC SECTION 1129B.4.1 & 1129B.4.2. N 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 CR CR CR CR F.E.C. F. E . C . F.E.C. CR CR F.E.C. CR R NOTE:ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED PRIOR TO FINAL INSPECTION AND SUBJECT TO BUILDING INSPECTOR. CEILING-MOUNTED EXIT SIGN WITH BATTERY BACKUP, SHADED QUADRANT INDICATES FACE OF LETTERING, SIGN TO INCLUDE DIRECTIONAL ARROW AS INDICATED. REQUIRED ACCESSIBLE EXIT EXISTING ACCESSIBLE EXIT COMMON PATH OF EGRESS TRAVEL (C.P.E.T.). MAXIMUM TRAVEL DISTANCE. F.E.C.FIRE EXTINGUISHER CABINET AGGREGATE OCCUPANT LOAD AT DOOR. AGGREGATE OCCUPANT LOAD AT DESIGNATED POINT. ORIGINATING OCCUPANT LOAD. 0 0 0 CUMULATIVE OCCUPANT LOAD FROM ADJOINING ROOMS.0 DIRECTION OF TRAVEL. 1 CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150D OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 HALLWAY 158 HALLWAY 159 HALLWAY 160 HALLWAY 161 HALLWAY 162 HALLWAY 163 HALLWAY 164 BREAK AREA (B) 455 S.F. / 15.00 SF 31 OCCUPANTS PHONE ROOM (B) 41 S.F. / 150.00 SF 1 OCCUPANTS OFFICE (B) 10,959 S.F. / 150.00 SF 74 OCCUPANTS STORAGE (B) 78 S.F. / 300.00 SF 1 OCCUPANTS WAITING (B) 541 S.F. / 15.00 SF 37 OCCUPANTS STORAGE (B) 178 S.F. / 300.00 SF 1 OCCUPANTS CONFERENCE (B) 246 S.F. / 15.00 SF 17 OCCUPANTS STORAGE (B) 177 S.F. / 300.00 SF 1 OCCUPANTS STORAGE (B) 117 S.F. / 300.00 SF 1 OCCUPANTS STORAGE (B) 62 S.F. / 300.00 SF 1 OCCUPANTS CONFERENCE (B) 552 S.F. / 15.00 SF 37 OCCUPANTS N.I.C. 15' COMMON PATH OF TRAVEL DIAGONAL 207'-3" 101 101 102 108 119 119 119 104 106 107 113113 109 109 TYP. 110 112 115 118 109 119 1 3 7 ' M A X . T R A V E L D I S T A N C E 20' COMMON PATH OF TRAVEL 119 119 119 120 SUITE 110 SUITE 100 EXIT W I DTH 72" EXIT WIDTH 72" EXIT W I DTH 72" 11 1 137131 1 31 1 43 ' C . P . E . T . 32 32 131 80 ' M A X . T R A V E L D I S T A N C E 1 90 ' M A X . T R A V E L D I S T A N C E 1 1 37 37 61 1 1 17 1 1 194021 1 1 11 4 1 98' MAX. TRAVEL DISTANCE 52' C.P.E.T. 11 45 11 1 1 1 3 42 2 1 1 1 1 4 8 4 2 1 9 1 1 1 37 1 1 1 1 1 1 3 50 64 52 116 1 1 2 61 SEPARAT ION OF EXITS > D/3 130'-8 1/2" 54 1 3 1 4 61 62 94 49 1 2 1 ' M A X . T R A V E L D I S T A N C E 1 0 8 ' M A X . T R A V E L D I S T A N C E 46' C.P.E.T. 76' C.P.E.T. 20' C.P.E.T. EX I T W I D T H 86 " 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 3/ 1 6 / 2 0 2 3 4 : 3 4 : 3 1 P M K. BURGER CB / JG SDG22-6057-00 OC C U P A N C Y A N D E G R E S S P L A N I0.5 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & S U I T E 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 101 EXISTING FULLY ACCESSIBLE RESTROOM FACILITY. 102 DENOTES WALL-MOUNTED TACTILE SIGN LOCATION, INDICATING "EXIT". PROVIDE NEW AS REQUIRED TO MATCH EXISTING. SEE DETAIL 21 ON SHEET I0.3. AT GLASS APPLICATIONS, PROVIDE CLEAR ADHESIVE FOR SEAMLESS ADHESION TO GLASS. NO VISIBLE MARKINGS FROM OPPOSITE SIDE. 104 EXISTING 6'-0" X 8'-0" DOUBLE STOREFRONT DOOR SYSTEM WITH LATCH SET TO REMAIN. RETROFIT DOOR WITH NEW PANIC HARDWARE (AS REQUIRED) AND PROVIDE ELECTRIFIED HARDWARE FOR NEW CARD READER AT EXTERIOR. PROVIDE SIGNAGE ABOVE DOOR THAT READS "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." 106 DENOTES LOCATION OF NEW TENANT SEPARATION WALL. 107 NEW FULLY ACCESSIBLE UNISEX RESTROOM FACILITY WITH REQUIRED WALL AND DOOR SIGNAGE. SEE DETAIL 22 ON SHEET I0.3. 108 EXISTING EXIT TO REMAIN. PROVIDE NEW EXIT SIGN AT THIS DOOR IF NOT EXISTING. 109 EXISTING ACCESSIBLE DOOR WITH CODE COMPLIANT HARDWARE TO REMAIN. CONTRACTOR TO FIELD VERIFY EXISTING DOOR HARDWARE. IF EXISTING DOOR IS EQUIPPED WITH KEY OPERATED LOCKING DEVICE FROM EGRESS SIDE, THEN THE FOLLOWING CODE REQUIREMENTS SHALL BE APPLICABLE: THE LOCKING DEVICE MUST BE READILY DISTINGUISHABLE AS LOCKED. A READILY VISIBLE DURABLE SIGN MUST BE POSTED ON THE EGRESS SIDE OR ADJACENT TO DOOR STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN THE SPACE IS OCCUPIED." THE SIGN SHALL BE IN LETTERS 1 INCH HIGH ON A CONTRASTING BACKGROUND. THE USE OF A KEY OPERATED DEVICE IS REVOCABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE, CBC 1010.1.9.3. 110 ALL EXIT DOORS, INCLUDING SECURITY GRILLES, SHALL BE OPENABLE FROM THE INSIDE OF TENANT SPACE WITHOUT THE USE OF ANY SPECIAL KNOWLEDGE OR EFFORT WHEN THE SPACE IS OCCUPIED. COMPLY WITH 402.8.8 #3, 1010.1.9, 1010.1.9.3 CBC, AND 1010.1.4.4. 112 PROVIDE MEANS OF EGRESS LIGHTING WITH EMERGENCY POWER BACK-UP SUPPLY TO COMPLY WITH 1008.3 CBC. 113 EXISTING UNISEX RESTROOM FACILITY. 115 THICK DASHED LINE NOTES ACCESSIBLE ROUTES OF TRAVEL FROM PRIMARY ENTRANCE TO THE BUILDING AND THE PRIMARY PATH OF TRAVEL TO THE SPECIFIC AREA OF ALTERATION AND AREAS SERVING THE SPECIFIC AREA OF ALTERATION. ALL SERVICES AND AREAS OF ALTERATION SHALL BE MADE ACCESSIBLE FOR THE DISABLED (11B-202.4). SEE SHEET A0.3 FOR ACCESSIBLE DETAILS. 118 NOT AN EXIT. THIS DOOR IS TO REMAIN LOCKED AT ALL TIMES. 119 GENERAL CONTRACTOR TO PROVIDE AND INSTALL WALL-MOUNTED TACTILE "EXIT ROUTE" SIGN AT LOCATIONS INDICATED. SEE DETAIL 23 ON I0.3. 120 EXISTING WALL-MOUNTED TACTICLE SIGN, INDICATING "EXIT". 1. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY MEANS OF EGRESS IS OCCUPIED (CBC 1008.2). 2. EXIT SIGNS ARE REQUIRED WHEN TWO OR MORE EXISTS MUST BE PROVIDED PER CBC 1013.3 FOR EXIT SIGN ILLUMINATION REQUIREMENTS. 3. EXITS SHALL NOT PASS THROUGH KITCHENS, STORE ROOMS, OR SPACES USED FOR SIMILAR PURPOSES, CBC 1016.2.5. 4. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE, CBC 1010.1.2.1. 5. PANIC HARDWARE, SHALL HAVE THE ACTIVATING MEMBER MOUNTED AT A HEIGHT OF 34" MINIMUM AND 48" MAXIMUM ABOVE THE FINISHED FLOOR, CBC 1010.1.9.2. 6. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. WHEN EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOOR KNOB OR SURFACE MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION, CBC 1010.1.9.4. AND 1010.1.9.4.4. 7. BUILDING OCCUPANTS MUST HAVE ACCESS TO TWO EXITS UNLESS ONE EXIT IS PERMITTED BY CBC TABLE 1003.2.1. OR TABLE 1006.3.2.1.(1) OR 1006.3.2.(2). 8. WHEN MORE THAN EXIT IS REQUIRED, DEAD ENDS SHALL NOT EXCEED LIMITATIONS ESTABLISHED BY CBC SEC 1020.4. RESTROOM SUMMARY MAX. TRAVEL DISTANCE TO EXITS MAXIMUM TRAVEL DISTANCE TO EXITS (1017.2 SPRINKLERED BUILDING) B/BUSINESS (OFFICE) .................................................................... 300 FEET MAX. LEGEND KEYNOTES: MAX. COMMON PATH OF TRAVEL MAX. COMMON PATH OF TRAVEL DISTANCE (1006.2.1 SPRINKLERED BUILDING) B/BUSINESS (OFFICE) .................................................................... 100 FEET MAX. EGRESS PLAN NOTES OCCUPANT LOAD SUMMARY OCCUPANCY USE OCCUPANCY CLASSIFICATION AREA OCCUPANT LOAD FACTOR OCCUPANT LOAD BREAK AREA B 455 SF 15 31 PHONE ROOM B 41 SF 150 1 OFFICE B 10,959 SF 150 74 STORAGE B 78 SF 300 1 WAITING B 541 SF 15 37 STORAGE B 178 SF 300 1 CONFERENCE B 246 SF 15 17 STORAGE B 177 SF 300 1 STORAGE B 117 SF 300 1 STORAGE B 62 SF 300 1 CONFERENCE B 552 SF 15 37 TOTALS: 11 13,407 SF 202 SCALE: 1/8" = 1'-0"1FIRST FLOOR OCCUPANCY AND EGRESS PLAN 0 4' 8'16' 32' 1/8"=1'-0" FIXTURES REQUIRED (BASED ON CPC TABLE 422.1): WC . M WC . W UR I N A L S LA V A T O R Y M LA V A T O R Y W DR I N K I N G F O U N T A I N S OFFICE 13,407 S.F. / 200 = 68 / 2 = 34 TOTAL REQUIRED 1 3 1 1 1 1 TOTAL PROVIDED*2 3 1 2 2 ** *IN ADDITION TO THE EXISTING ACCESSIBLE RESTROOM FACILITIES, TENANT AREA OF IMPROVEMENT INCLUDES (3) SINGLE FIXTURE ACCESSIBLE RESTROOMS TO BE IN COMPLIANCE WITH CBC 11B REQUIREMENTS. **R.O. WATER TO BE THROUGH WATER DISPENSER AT TENANT REFRIGERATOR. REFRIGERATOR WATER STATION SHALL BE PERMITTED TO BE SUBSTITUTED FOR DRINKING FOUNTAIN PER CPC SECTION 415.1 AND COMPLIES WITH CBC 11B-211. EGRESS ANALYSIS DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 1 20 2 3 - 0 3 - 1 6 IS S U E F O R P L AN C H E C K C O R R E C T I O N S N MIN EGRESS WIDTH EGRESS COMPONENT DOOR OCCUPANT LOAD SERVED 202 MINIMUM CALCULATED WIDTH 202 * 0.2 = 49.8" WIDTH PROVIDED 302" 1 1 1 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 5 1 P M K. BURGER CB / JG SDG22-6057-00 CA L G R E E N N O T E S I0.6a CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 CALIFORNIA GREEN BUILDINGS STANDARDS CODE 2019 - NON-RESIDENTIAL MANDATORY MEASURES SECTION 5.201 ENERGY EFFICIENCY PERFORMANCE REQUIREMENTS 5.303.3.1 WATER CLOSETS. 5.410.2 COMMISSIONING. SECTION 5.410 BUILDING MAINTENANCE AND OPERATION 5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS. 5.408.1.4 DOCUMENTATION. 5.408.1 CONSTRUCTION WASTE MANAGEMENT. SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING SECTION 5.407 WEATHER RESISTANCE AND MOISTURE MANAGEMENT 5.504.4.1 ADHESIVES, SEALANTS AND CAULKS. 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. SECTION 5.504 POLLUTANT CONTROL 5.410.2.4 FUNCTIONAL PERFORMANCE TESTING. TABLE 5.504.4.2 SEALANT VOC LIMIT LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER TABLE 5.504.4.1 ADHESIVE VOC LIMIT LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER CAL Green GENERAL NOTESTABLE 5.504.4.3 VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS GRAMS OF VOC PER LITER OF COATING, LESS WATER AND LESS EXEMPT COMPOUNDS 1. THESE DOCUMENTS HAVE BEEN CREATED IN CONFORMANCE WITH DESIGN RELATED CODE REQUIREMENTS. CONFORMANCE OF CONSTRUCTION- RELATED ACTIVITIES WITH GOVERNING CODES ARE THE GENERAL CONTRACTOR'S RESPONSIBILITY, UNLESS OTHERWISE NOTED. 2. THE COST OF AND LIABILITY PROTECTION FOR SERVICES PROVIDED BY THIRD PARTY COMMISSIONING AGENTS AND SPECIAL INSPECTORS REQUIRED BY THE AUTHORITY HAVING JURISDICTION SHALL BE A SOLE RESPONSIBILITY OF THE BUILDING OWNER OR TENANT. 3. ALL MATERIAL AND PRODUCT SUBSTITUTION REQUESTS SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO BID AND/OR PURCHASE AND INSTALLATION. THE ARCHITECT RESERVES THE RIGHT TO REJECT ANY SUBSTITUTION REQUEST THAT DOES NOT STRICTLY CONFORM TO THE DESIGN DOCUMENTS OR THEIR INTENT. UPON REJECTION, THE CONTRACTOR IS REQUIRED TO PROVIDE SPECIFIED ITEMS AT NO ADDITIONAL COST TO THE OWNER. 4. GENERAL CONTRACTOR IS HIGHLY ENCOURAGED TO REVIEW THE SAMPLE WORKSHEETS PROVIDED IN CHAPTER 8 OF THE 2019 CALIFORNIA GREEN BUILDINGS STANDARDS CODE TO PREPARE FOR THE CREATION OF REQUIRED CONSTRUCTION WASTE MANAGEMENT DOCUMENTS. 5. IN THE EVENT OF ANY DISCREPANCY BETWEEN THIS DOCUMENT AND THE CURRENT 2019 CALIFORNIA GREEN BUILDINGS STANDARDS CODE AND AMENDMENTS, THE TEXT OF THE CODE AND AMENDMENTS SHALL GOVERN. NEWLY CONSTRUCTED PROJECTS AND ADDITIONS WHICH DISTURB LESS THAN ONE ACRE OF LAND SHALL PREVENT THE POLLUTION OF STORMWATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES THROUGH ONE OR MORE OF THE MEASURES DISCRIBED IN SECTION 5.106.1.1 AND 5.106.1.2 5.106.1 STORM WATER POLLUTION PREVENTION 5.106.4 BICYCLE PARKING COMPLY WITH SECTIONS 5.106.4.1 AND 5.106.4.2: OR MEET LOCAL ORDINANCE, WHICHEVER IS STRICTER. NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. 5.106.4.1.1 SHORT-TERM BICYCLE PARKING IF THE PROJECT IS ANTICIPATED TO GENERATE VISITOR TRAFFIC, PROVIDE PERMANENTLY ANCHORED BICYCLE RACKS WITHIN 200 FEET OF THE VISITORS' ENTRANCE, READILY VISIBLE TO PASSERS-BY, FOR 5 PERCENT OF VISITOR MOTORIZED VEHICLE PARKING CAPACITY, WITH A MINIMUM OF ONE TWO-BIKE CAPACITY RACK. NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. 5.106.4.1.2 LONG-TERM BICYCLE PARKING FOR BUILDINGS WITH OVER 10 TENANT-OCCUPANTS, PROVIDE SECURE BICYCLE PARKING FOR 5 PERCENT OF MOTORIZED VEHICLE PARKING CAPACITY. ACCEPTABLE PARKING FACILITIES SHALL BE CONVENIENT FROM THE STREET. SHALL MEET ONE OF THE CRITERIA LISTED IN THIS SECTION. NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. 5.106.5.2 DESIGNATED PARKING FOR CLEAN AIR VEHICLES PROVIDE 10% DESIGNATED PARKING FOR ANY COMBINATION OF LOW-EMITTING, FUEL-EFFICIENT AND CARPOOL/VAN POOL VEHICLES. TABLE 5.106.5.2 NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. SECTION 5.106 SITE DEVELOPMENT 5.106.8 LIGHT POLLUTION REDUCTION SEE ELECTRICAL DRAWINGS FOR PHOTOMETRIC STUDY AND FIXTURE TYPES/ CUTOFFS. CONSTRUCTION PLANS SHALL INDICATE HOW SITE GRADING OR A DRAINAGE SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE WATER INCLUDE THOSE SHOWN IN ITEMS 1 THROUGH 5 LISTED IN THIS SECTION.. 5.106.10 GRADING AND PAVING NO SITE WORK IS PROPOSED IN THIS PROJECT SCOPE. SEE ELECTRICAL SHEETS FOR COMPLIANCE WITH CURRENT ENERGY PERFORMANCE DESIGN APPLICABLE TO THE SCOPE OF THIS PROJECT SECTION 5.303 INDOOR WATER USE SEE PLUMBING SHEETS FOR METER LOCATION. SUBMETERING PROVIDED AT THIS TIME ONLY AS REQUIRED FOR THE SCOPE OF THIS PROJECT 5.303.1.1 BUILDINGS IN EXCESS OF 50,000 SF. SEE PLUMBING DRAWINGS. 5.303.1.2 EXCESS CONSUMPTION. SEE PLUMBING DRAWINGS. 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SEE PLUMBING DRAWINGS. 5.303.3.2.1 WALL-MOUNTED URINALS. SEE PLUMBING DRAWINGS. THE CALIFORNIA ENERGY COMMISSION WILL CONTINUE TO ADOPT MANDATORY BUILDING STANDARDS. SEPARATE SUBMETERS SHALL BE INSTALLED FOR THE USES DESCRIBED IN SECTION 5.303.1.1 AND 5.303.1.2. A SEPARATE SUBMETER OR METERING DEVICE SHALL BE PROVIDED FOR ANY TENANT WITHIN A BUILDING OR WITHIN AN ADDITION THAT IS PROJECTED TO CONSUME MORE THAN 1,000 GAL/DAY (3800 L/DAY). PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING: THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR TANK-TYPE TOILETS. THE EFFECTIVE FLUSH VOLUME OF ALL FLOOR-MOUNTED URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. 5.303.3.3.1 SINGLE SHOWERHEADS. SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 80 PSI. SHOWERHEADS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR SHOWERHEADS. 5.303.3.3.2 MULTIPLE SHOWERHEADS SERVING ONE SHOWER. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OULETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OULET TO BE IN OPERATION AT A TIME. 5.303.3.4 FAUCETS AND FOUNTAINS. FOR THOSE OCCUPANCIES WITHIN THE AUTHORITY OF CALIFORNIA BUILDING STANDARDS COMMISSION AS SPECIFIED IN SECTION 103, THE PROVISIONS OF SECTION 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATION TO THE BUILDING. SEE PLUMBING DRAWINGS. NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION ENVELOPE AS REQUIRED BY CALIFORNIA BUILDING CODE SECTION 1403.2 AND CALIFORNIA ENERGY CODE SECTION 150, MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT. NO EXTERIOR FACADE WORK IS PROPOSED IN THIS SCOPE OF WORK. 5.407.2 MOISTURE CONTROL EMPLOY MOISTURE CONTROL MEASURES BY THE FOLLOWING METHODS; 5.407.2.1 SPRINKLERS PREVENT IRRIGATION SPRAY ON STRUCTURES. NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. 5.407.2.2 ENTRIES AND OPENINGS DESIGN EXTERIOR ENTRIES AND OPENINGS TO PREVENT WATER INTUSION INTO BUILDING. NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. 5.407.2.2.1 EXTERIOR DOOR PROTECTION. PRIMARY EXTERIOR ENTRIES SHALL BE COVERED TO PREVENT WATER INTRUSION BY USING NONABSORBENT FLOOR AND WALL FINISHES WITHIN AT LEAST 2 FEET AROUND AND PERPENDICULAR TO SUCH OPENINGS PLUS AT LEAST ONE OF THE ITEMS 1 THROUGH 4 LISTED IN THIS SECTION. 5.407.2.2.2 FLASHING. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2 OR 5.408.1.3; OR MEET LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT. CONTRACTOR TO DEVELOP CONSTRUCTION WASTE MANAGEMENT PLAN AND SUBMIT IT TO THE CITY FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. 5.408.1.1 CONSTRUCTION WASTE MANAGEMENT PLAN. (MANDATORY) WHERE A LOCAL JURISDICTION DOES NOT HAVE A CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE THAT IS MORE STRINGENT, SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN THAT COMPLIES WITH ITEMS 1 THROUGH 4 OF THIS SECTION. CONTRACTOR TO DEVELOP CONSTRUCTION WASTE MANAGEMENT PLAN AND SUBMIT IT TO THE CITY FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. 5.408.1.2 WASTE MANAGEMENT COMPANY. CONTRACTOR TO DEVELOP CONSTRUCTION WASTE MANAGEMENT PLAN AND SUBMIT IT TO THE CITY FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. 5.408.1.3 WASTE STREAM REDUCTION ALTERNATIVE. THE COMBINED WEIGHT OF NEW CONSTRUCTION DISPOSAL THAT DOES NOT EXCEED TWO POUNDS PER SQUARE FOOT OF BUILDING AREA MAY BE DEEMED TO MEET THE 50 PERCENT MINIMUM REQUIREMENT AS APPROVED BY THE ENFORCING AGENCY. CONTRACTOR TO DEVELOP CONSTRUCTION WASTE MANAGEMENT PLAN AND SUBMIT IT TO THE CITY FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH SECTIONS 5.408.1.1 THROUGH 5.408.1.3. THE WASTE MANAGEMENT PLAN SHALL BE UPDATED AS NECESSARY AND SHALL BE ACCESSIBLE DURING CONSTRUCTION FOR EXAMINATION BY THE ENFORCING AGENCY. CONTRACTOR TO DEVELOP CONSTRUCTION WASTE MANAGEMENT PLAN AND SUBMIT IT TO THE CITY FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. 100 PERCENT OF TREES, STUMPS, ROCKS AND ASSOCIATED VEGETATION AND SOILS RESULTING PRIMARILY FROM LAND CLEARING SHALL BE REUSED OR RECYCLED. FOR A PHASED PROJECT, SUCH MATERIAL MAY BE STICKPILED ON SITE UNTIL THE STORAGE SITE IS DEVELOPED. NO SITE WORK IS PROPOSED IN THIS PROJECT SCOPE. TI SPECIFICATIONS TO COMPLY. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE DEPOSITING, STORAGE AND COLLECTION OF NON-HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING (AT A MINIMUM) PAPER, CORRUGATED CARDBOARD, GLASS, PLASTICS AND METALS OR MEET A LAWFULLY ENACTED LOCAL RECYCLING ORDINANCE, IF MORE RESTRICTIVE. FOR NEW BUILDINGS 10,000 SQUARE FEET AND OVER, BUILDING COMMISSIONING SHALL BE INCLUDED IN THE DESIGN AND CONSTRUCTION PROCESS OF THE BUILDING PROJECT TO VERIFY THAT THE BUILDING SYSTEMS AND COMPONENTS MEET THE OWNER'S OR OWNER REPRESENTATIVE'S PROJECT REQUIREMENTS. COMMISSIONING SHALL BE PERFORMED IN ACCORDANCE WITH THIS SECTION BY TRAINED PERSONNEL WITH EXPERIENCE ON PROJECTS OF COMPARABLE SIZE AND COMPLEXITY. COMMISSIONING REQUIREMENTS SHALL INCLUDE: ITEMS 1 THROUGH 7 LISTED IN THIS SECTION. EXCEPTIONS: 1. UNCONDITIONED WAREHOUSES OF ANY SIZE. 2. AREAS UNDER 10,000 SQUARE FEET USED FOR OFFICES OR OTHER CONDITIONED ACCESSORY SPACES WITHIN UNCONDITIONED WAREHOUSES. 3. TENANT IMPROVEMENTS UNDER 10,000 SQUARE FEET AS DESCRIBED IN SECTION 303.1.1. 4. OPEN PARKING GARAGES OF ANY SIZE, OR OPEN PARKING GARAGE AREAS, OF ANY SIZE, WITHIN A STRUCTURE. TI SPECIFICATIONS TO COMPLY. 5.410.2.1 OWNER'S OR OWNER REPRESENTATIVE'S PROJECT REQUIREMENTS (OPR). THE EXPECTATIONS AND REQUIREMENTS OF THE BUILDING APPROPRIATE TO ITS PHASE SHALL BE DOCUMENTED BEFORE THE DESIGN PHASE OF THE PROJECT BEGINS. THIS DOCUMENTATION SHALL INCLUDE ITEMS 1 THROUGH 6 LISTED IN THIS SECTION. TI SPECIFICATIONS TO COMPLY. 5.410.2.2 BASIS OF DESIGN (BOD). A WRITTEN EXPLANATION OF HOW THE DESIGN OF THE BUILDING SYSTEMS MEETS THE OPR SHALL BE COMPLETED AT THE DESIGN PHASE OF THE BUILDING PROJECT. THE BASIS OF DESIGN DOCUMENT SHALL COVER ITEMS 1 THROUGH 6 LISTED IN THIS SECTION. 5.410.2.3 COMMISSIONING PLAN A COMMISSIONING PLAN DESCRIBING HOW THE PROJECT WILL BE COMMISSIONED SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2.3. FUNCTIONAL PERFORMANCE TEST SHALL DEMONSTRATE THE CORRECT INSTALLATION AND OPERATION OF EACH COMPONENT, SYSTEM AND SYSTEM-TO-SYSTEM INTERFACE IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. FUNTIONAL PERFORMANCE TESTING REPORTS SHALL CONTAIN INFORMATION ADDRESSING EACH OF THE BUILDING COMPONENTS TESTED, THE TESTING METHODS UTILIZD, AND INCLUDE ANY READINGS AND ADJUSTMENTS MADE. TI SPECIFICATIONS TO COMPLY. SECTION 5.503 FIREPLACES INSTALL ONLY A DIRECT-VENT SEALED-COMBUSTION GAS OR SEALED WOOD-BURNING FIREPLACE OR A SEALED WOODSTOVE AND REFER TO RESIDENTIAL REQUIREMENTS IN THE CALIFORNIA ENERGY CODE, TITLE 24, PART 6, SUBCHAPTER 7, SECTION 150. N/A. 5.503.1.1 WOODSTOVES. WOODSTOVES SHALL COMPLY WITH US EPA PHASE II EMISSION LIMITS. TI SPECIFICATIONS TO COMPLY. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. FINISH MATERIALS SHALL COMPLY WITH SECTIONS 5.504.4.1 THROUGH 5.504.4.4. TI SPECIFICATIONS TO COMPLY. TI SPECIFICATIONS TO COMPLY. TI SPECIFICATIONS TO COMPLY. 5.504.4.3 PAINTS AND COATINGS. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, AS SHOWN IN TABLE 5.504.4.3, UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE 5.504.4.3 SHALL BE DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36 AND 4.37 OR THE 007 CALIFORNIA AIR RESOURCES BOARD, SUGGESTED CONTROL MEASURE, AND THE ORRESPONDING FLAT, NONFLAT OR NONFLAT-HIGH GLOSS VOC LIMIT IN TABLE 5.504.4.3 SHALL APPLY. THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION. 5.504.4.3.2 VERIFICATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: 1. MANUFACTURER'S PRODUCT SPECIFICATION 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS SUBMITTAL AVAILABLE UPON REQUEST. 5.504.4.4 CARPET SYSTEMS. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). 5.504.4.4.2 CARPET ADHESIVE. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 5.504.4.1. 5.504.4.5. COMPOSITE WOOD PRODUCTS. 5.504.4.5.3 DOCUMENTATION. HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN TABLE 5.504.4.5 TI SPECIFICATIONS TO COMPLY. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE ITEMS 1 THROUGH 5 LISTED IN SECTION 5.504.4.5.3. DOCUMENTATION AVAILABLE UPON REQUEST. 5.504.4.6 RESILIENT FLOORING SYSTEMS. WHERE RESILIENT FLOORING IS INSTALLED AT LEAST 80 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PULBIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIROMENTAL CHAMBERS." VERSION 1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). 5.504.4.6.1 VERIFICATION OF COMPLIANCE. DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT FLOORING MATERIALS MEET THE POLLUTANT EMISSION LIMITS. TI SPECIFICATIONS TO COMPLY. 5.504.5.3 FILTERS. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MERV OF 8. MERV 8 FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. TI SPECIFICATIONS TO COMPLY. 5.106.5.3 ELECTRIC VEHICLE (EV) CHARGING 5.106.5.3.2 MULTIPLE CHARGING SPACE REQUIREMENTS TABLE 5.106.5.3.3 NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. 5.106.5.3.3 EV CHARGING SPACE CALCULATION 5.106.5.3.4 [N] IDENTIFICATION. THE SERVICE PANEL OR SUBPANEL(S) CIRCUIT DIRECTORY SHALL IDENTIFY THE RESERVED OVERCURRENT PROTECTIVE DEVICE SPACE(S) FOR FUTURE EV CHARGING AS " EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE." 5.106.5.3.5 [N]. FUTURE CHARGING SPACES QUALIFY AS DESIGNATED PARKING AS DESCRIBED IN SECTION 5.106.5.2 DESIGNATED PARKING. NOTES: 1. THE CALIFORNIA DEPARTMENT OF TRANSPORTATION ADOPTS AND PUBLISHES THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES ( CALIFORNIA MUTCD) TO PROVIDE UNIFORM STANDARDS AND SPECIFICATIONS FOR ALL OFFICIAL TRAFFIC CONTROL DEVICES IN CALIFORNIA. ZERO EMISSION VEHICLE SIGNS AND PAVEMENT MARKINGS CAN BE FOUND IN THE NEW POLICIES AND DIRECTIVES NUMBER 13-01. www.dot.ca.gov/hq/traffops/policy/13-01.pdf 2. SEE VEHICLE CODE SECTION 22511 FOR EV CHARGING SPACES SIGNAGE IN OFF-STREET PARKING FACILITIES AND FOR USE OF EV CHARGING SPACES. 3. THE GOVERNOR'S OFFICE OF PLANNING AND RESEARCH PUBLISHED A ZERO-EMISSION VEHICLE COMMUNITY READINESS GUIDEBOOK WHICH PROVIDES HELPFULL INFORMATION FOR LOCAL GOVERNMENTS, RESIDENTS AND BUSINESSES. www.opr.ca.gov/docs/zev_guidebook.pdfwww.opr.ca.gov/docs/zev_guidebook.pdf 5.303.5 AREAS OF ADDITION OR ALTERATION. 5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1401.1 OF THE CALIFORNIA PLUMBING CODE AND IN CHAPTER 6 OF THIS CODE. ALL ADDITIONS CONDUCTED WITHIN A 12-MONTH PERIOD UNDER SINGLE OR MULTIPLE PERMITS, RESULTING IN AN INCREASE OF 30 PERCENT OR MORE IN FLOOR AREA, SHALL PROVIDE RECYCLING AREAS ON SITE. EXCEPTION: ADDITIONS WITHIN A TENANT SPACE RESULTING IN LESS THAN A 30-PERCENT INCREASE IN THE TENANT SPACE FLOOR AREA. 5.410.1.1 ADDITIONS. [A] 5.410.1.2 SAMPLE ORDINANCE. SPACE ALLOCATION FOR RECYCLING AREAS SHALL COMPLY WITH CHAPTER 18, PART 3, DIVISION 30 OFTHE PUBLIC RESOURCES CODE. CHAPTER 18 IS KNOWN AS THE CALIFORNIA SOLID WASTE REUSE AND RECYCLING ACCESS ACT OF 1991 (ACT). NOTE: A SAMPLE ORDINANCE FOR USE BY LOCAL AGENCIES MAY BE FOUND IN 5.410.1 RECYCLING BY OCCUPANTS. TABLE 5.504.4.5 FORMALDEHYDE LIMITS MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION. *(MAX. 5/16" THICK) 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS. LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.5 GALLONS PER MINUTE AT 60 PSI. 5.303.3.4.2 KITCHEN FAUCETS. KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 60PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60PSI, AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. 5.303.3.4.3 WASH FOUNTAINS. WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE/20 [RIM SPACE (INCHES) AT 60 PSI]. 5.303.3.4.4 METERING FAUCETS METERING FAUCETS SHALL NOT DELIVER MORE THAN 0.20 GALLONS PER CYCLE. 5.303.3.4.5 METERING FAUCETS FOR WASH FOUNTAINS METERING FAUCETS FOR WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.20 GALLONS PER MINUTE/20 [RIM SPACE (INCHES) AT 60 PSI]. NOTE: WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION. SEE PROJECT SPECIFICATIONS. 5.504.4.3.1 AEROSOL PAINTS AND COATINGS. AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN SECTION 94522(a)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(c)(2) AND (d)(2) OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE JURISDICTION OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT ADDITIONALLY COMPLY WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8 RULE 49. CONSTRUCTION SHALL COMPLY WITH SECTION 5.106.5.3.1 OR SECTION 5.106.5.3.2 TO FACILITATE FUTURE INSTALLATION OF ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). TABLE 5.106.5.3.3 SHALL BE USED TO DETERMINE IF SINGLE OR MULTIPLE CHARGING SPACE REQUIREMENTS APPLY FOR THE FUTURE INSTALLATION OF EVSE. EXCEPTIONS: ON A CASE BY CASE BASIS, WHERE THE LOCAL ENFORCING AGENCY HAS DETERMINED EV CHARGING AND INFRASTRUCTURE IS NOT FEASIBLE DUE TO ONE OF THE FOLLOWING: 1. WHEN THERE IS INSUFFICIENT ELECTRICAL SUPPLY. 2. WHEN THERE IS EVIDENCE SUITABLE TO THE LOCAL ENFORCING AGENCY SUBSTANTIATING THAT ADDITIONAL LOCAL UTILITY INFRASTRUCTURE DESIGN REQUIREMENTS, DIRECTLY RELATED TO THE IMPLEMENTATION OF SECTION 5.106.5.3, MAY ADVERSELY IMPACT THE CONSTRUCTION COST OF THE PROJECT. INSTALL FLASHINGS INTEGRATED WITH A DRAINAGE PLANE. INSTALLED FILTERS SHALL BE CLEARLY LABELED BY THE MANUFACTURER INDICATING THE MERV RATING. 5.504.5.3.1 LABELING. TOTAL NUMBER OF CLEAN AIR VEHICLE PARKING SPACES REQUIRED NUMBER OF REQUIRED SPACES 0-9 0 10-25 3 26-50 6 51-75 9 76-100 12 101-150 18 151-200 21 201 AND OVER AT LEAST 12 PERCENT OF TOTAL TOTAL NUMBER OF PARKING SPACES NUMBER OF REQUIRED EV CHARGING SPACES 0-9 0 10-25 26-50 2 51-75 4 76-100 7 101-150 9 151-200 13 200 AND OVER 10 PERCENT OF TOTAL ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILES ADHESIVES 65 VCT AND ASPHALTS TILE ADHESIVES 50 DRYWALL AND PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVES 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVE NOT SPECIFICALLY USED 50 SPECIALITY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBRANE ADHESIVE 140 TOP AND TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 SEALANTS CURRENT VOC LIMIT. ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE - PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS NONPOROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 COATING CATEGORY CURRENT VOC LIMIT FLAT COATING 50 NONFLAT COATING 100 NONFLAT HIGH GLOSS COATING 150 SPECIALTY COATING ALUMINUM ROOF COATING 400 BASEMENT SPECIALITY COATING 400 BITUMINOUS ROOF COATING 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/ MASONARY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUND 250 GRAPHIC ART COATINGS (SIGN PAINT) 500 HIGH-TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLORS COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS AND UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS: CLEAR 730 OPAQUE 550 SPECIALITY PRIMERS, SEALERS AND UNDERCOATERS: 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOLS COATING 340 TRAFFICS MARKING COATINGS 100 TUB AND TILE REFINISH COATINGS 420 WATER PROOFING MEMBRANES 250 WOOD COATING 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD* 0.13 THE EFFECTIVE FLUSH VOLUME OF WALL-MOUNTED URINALS SHALL NOT EXCEED 0.125 GALLONS PER FLUSH 5.303.3.2.2 FLOOR-MOUNTED URINALS. 5.303.4.1 FOOD WASTE DISPOSER DISPOSERS SHALL EITHER MODULATE THE USE OF WATER TO NO MORE THAN 1 GPM WHEN THE DISPOSER IS NOT IN USE (NOT ACTIVELY GRINDING FOOD WASTE/NO-LOAD) OR SHALL AUTOMATICALLY SHUT OFF AFTER NO MORE THAN 10 MINUTES OF INACTIVITY. DISPOSERS SHALL USE NO MORE THAN 8 GPM OF WATER. 5.408.2 UNIVERSAL WASTE. [A] GENERAL CONTRACTOR TO PROPERLY DISPOSE OF AND DIVERT FROM LANDFILLS UNIVERSAL WASTE ITEMS SUCH AS FLUORESCENT LAMPS AND BALLAST AND MERCURY CONTAINING THERMOSTATS AS WELL AS OTHER CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS AS MENTIONED IN THE CALIFORNIA UNIVERSAL WASTE RULE DOCUMENT: http://www.dtsc.ca.gov/lawregspolicies/regs/upload/oeara_regs_uwr_finaltext.pdf 1. ADHESIVES, ADHESIVE BONDING PRIMERS ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2. SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS (CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE CHLORIDE, PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS AS SPECIFIED IN SUBSECTION 2, BELOW. 2 AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER EQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507. 5.304.2 OUTDOOR WATER USE IN LANDSCAPE AREAS EQUAL TO OR GREATER THAN 500 SF. 5.304.3 OUTDOOR WATER USE IN REHABILITATED LANDSCAPE PROJECTS EQUAL TO OR GREATER THAN 2,500 SF. 5.304.4 OUTDOOR WATER USE IN LANDSCAPE AREAS OF 2,500 SF OR LESS. 5.304.5 GRAYWATER OR RAINWATER USE IN LANDSCAPE AREAS. 5.304.6 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. UTILIZE A WASTE MANAGEMENT COMPANY THAT CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH THIS SECTION EXCEPTIONS TO SECTION 5.408.1.1 AND 5.4081.2: 1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS 2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WORKING WITH LOCAL AGENCIES IF DIVERSION OR RECYCLE FACILITIES CAPABLE OF COMPLIANCE WITH THIS ITEM DO NOT EXIST. 3. DEMOLITION WASTE MEETING LOCAL ORDINANCE OR CALCULATED IN CONSIDERATION OF LOCAL RECYCLING FACILITIES AND MARKETS. OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH THE FOLLOWING: 1. THE MINIMUM REQUIREMENTS IN THE CALIFORNIA ENERGY CODE FOR LIGHTING ZONES 0-4 AS DEFINED IN CHAPTER 10, SECTION 10-114 OF THE CALIFORNIA ADMINISTRATIVE CODE; AND 2. BACKLIGHT (B) RATINGS AS DEFINED IN IES TM-15-11 (SHOWN IN TABLE A-1 IN CHAPTER 8); 3. UPLIGHT AND GLARE RATINGS AS DEFINED IN CALIFORNIA ENERGY CODE (SHOWN IN TABLES 130.2-A AND 130.2-B IN CHAPTER 8) AND 4. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN TABLE 5.106.8 [N], OR COMPLY WITH A LOCAL ORDINANCE LAWFULLY ENACTED PURSUANT TO SECTION 101.7, WHICHEVER IS MORE STRINGENT. EXCEPTIONS: 1. LUMINAIRES THAT QUALIFY AS EXCEPTIONS IN SECTIONS 130.2(B) AND 140.7 OF THE CALIFORNIA ENERGY CODE. 2. EMERGENCY LIGHTING. 3. BUILDING FACADE MEETING THE REQUIREMENTS IN TABLE 140.7-B OF THE CALIFORNIA ENERGY CODE, PART 6. 4. CUSTOM LIGHTING FEATURES AS ALLOWED BY THE LOCAL ENFORCING AGENCY, AS PERMITTED BY SECTION 101.8 ALTERNATE MATERIALS, DESIGNS AND METHODS OF CONSTRUCTION. 5. LUMINAIRES WITH LESS THAN 6,200 INITIAL LUMINAIRE LUMENS. SEPARATE SUBMETERS SHALL BE INSTALLED AS FOLLOWS: 1. FOR EACH INDIVIDUAL LEASED, RENTED OR OTHER TENANT SPACE WITHIN THE BUILDING PROJECTED TO CONSUME MORE THAN 100 GAL/DAY. 2. WHEN SEPARATE SUBMETERS FOR INDIVIDUAL BUILDING TENANTS ARE UNFEASIBLE, FOR WATER SUPPLIED TO THE FOLLOWING SUBSYSTEMS: A. MAKEUP WATER FOR COOLING TOWERS WHERE FLOW THROUGH IS GREATER 500 GPM (30L/S) B. MAKEUP WATER FOR EVAPORATIVE COOLERS GREATER THAN 6GPM (0.04L/S) C. STEAM AND HOT-WATER BOILERS WITH ENERGY INPUT MORE THAN 500,000 BTU/H (147 KW) WHEN MULTIPLE CHARGING SPACES ARE REQUIRED PER TABLE 5.106.5.3.3 RACEWAYS ARE REQUIRED TO BE INSTALLED AT THE RTIME OF CONSTRUCTION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. CONSTRUCTION PLANS AND SPECIFICATIONS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. THE TYPE AND LOCATION OF THE EVSE. 2. THE RACEWAYS SHALL ORIGINATE AT A SERVICE PANEL OR A SUBPANEL SERVING THE AREA, AND SHALL TERMINATE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF THE CHARGING EQUIPMENT AND INTO LISTED SUITABLE CABINETS, BOXES, ENCLOSURES, OR EQUIVALENT. 3. PLAN DESIGN SHALL BE BASED UPON 40-AMPERE MINIMUM BRANCH CIRCUITS. 4. ELECTRICAL CALCULATIONS SHALL SUBSTANTIATE THE DESIGN OF THE ELECTRICAL SYSTEM, TO INCLUDE THE RATING OF EQUIPMENT AND ANY ON-SITE DISTRIBUTION TRANSFORMERS AND HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY CHARGE ALL REQUIRED EV'S AT ITS FULL RATED AMPERAGE. 5. THE SERVICE PANEL OR SUBPANEL SHALL HAVE SUFFICIENT CAPACITY TO ACCOMMODATE THE REQUIRED NUMBER OF DEDICATED BRANCH CIRCUITS FOR THE FUTURE INSTALLATION OF THE EVSE. 5.106.1.1 LOCAL ORDINANCE 5.106.1.2 BEST MANAGEMENT PRACTICES (BMP) NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. 5.106.5.2.1 PARKING STALL MARKING NO SITE WORK PROPOSED IN THIS SCOPE OF WORK. (E) PARKING TO REMAIN AS IS. 5.106.5.3.1 SINGLE CHARGING SPACE REQUIREMENTS WHEN ONLY A SINGLE CHARGING SPACE IS REQUIRED PER TABLE 5.106.5.3.3, A RACEWAY IS REQUIRED TO BE INSTALLED AT THE TIME OF CONSTRUCTION. CONSTRUCTION PLANS AND SPECIFICATIONS SHALL INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: 1. THE TYPE AND LOCATION OF THE EVSE. 2. THE LISTED RACEWAY CAPABLE OF ACCOMODATING A 208/240-VOLT DEDICATED BRANCH CIRCUIT. 3. THE RACEWAY SHALL NOT BE LESS THAN TRADE SIZE 1" . 4. THE RACEWAY SHALL ORIGINATE AT A SERVICE PANEL OR SUBPANEL SERVING THE AREA, AND SHALL TERMINATE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF THE CHARGING EQUIPMENT. 5. THE SERVICE PANEL OR SUBPANEL SHALL HAVE SUFFICIENT CAPACITY TO ACCOMMODATE A MINIMUM 40-AMPERE DEDICATED BRANCH CIRCUITS FOR THE FUTURE INSTALLATION OF THE EVSE. TI SPECIFICATIONS TO COMPLY. TI SPECIFICATIONS TO COMPLY. ARCHITECTURAL SECTION 5.304 OUTDOOR WATER USE SEE PLUMBING DRAWINGS. COMPLY WITH LAWFULLY ENACTED STORMWATER MANAGEMENT AND/OR EROSION CONTROL ORDINANCE. PREVENT THE LOSS OF SOIL THROUGH WIND OR WATER EROSION BY IMPLEMENTING AN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROL AND GOOD HOUSEKEEPING BMP's. COMPLY WITH ALL LAWFULLY ENACTED STORMWATER DISCHARGE REGULATIONS FOR PROJECTS THAT (1) DISTURB ONE ACRE OR MORE OF LAND, OR (2) DISTURB LESS THAN ONE ACRE OF LAND BUT ARE PART OF A LARGER COMMON PLAN OF DEVELOPMENT OR SALE. SEE SECTION 5.106.2 FOR FULL DESCRIPTION OF REQUIREMENTS. REFER TO THE CURRENT APPLICABLE PERMITS ON THE STATE WATER RESOURCES CONTROL BOARD WEBSITE AT: www.waterboards.ca.gov/constructionstormwater 5.106.2 STORM WATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND 5.106.4.1.3 FOR ADDITIONS OR ALTERATIONS THAT ADD 10 OR MORE TENANT-OCCUPANT VEHICULAR PARKING SPACES, PROVIDE SECURE BICYCLE PARKING FOR 5 PERCENT OF THE TENANT VEHICULAR PARKING SPACES BEING ADDED, WITH A MINIMUM OF ONE BICYCLE PARKING FACILITY. 5.201.1 SCOPE. 5.303.1 METERS. 5.303.3.2 URINALS. 5.303.3.3 SHOWERHEADS. 5.303.4 COMMERCIAL KITCHEN EQUIPMENT. 5.407.1 WEATHER PROTECTION 5.410.1 RECYCLING BY OCCUPANTS. 5.503.1 GENERAL N/A. 5.504.1 TEMPORARY VENTILATION. SEE PROJECT SPECIFICATIONS. SEE _________________________. 18 5.106.8.1 FACING - BACKLIGHT. LUMINAIRES WITHIN 2MH OF A PROPERTY LINE SHALL BE ORIENTED SO THAT THE NEAREST PROPERTY LINE IS BEHIND THE FIXTURE, AND SHALL COMPLY WITH THE BACKLIGHT RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE LIGHTING ZONE AND DISTANCE TO THE NEAREST POINT OF THAT PROPERTY LINE. EXCEPTION CORNERS:IF TWO PROPERTY LINES (OR TWO SEGMENTS OF THE SAME PROPERTY LINE) HAVE EQUIDISTANT POINTS TO THE LUMINAIRE, THEN THE LUMINAIRE MAY BE ORIENTED SO THAT THE INTERSECTION OF THE TWO LINES (THE CORNER) IS DIRECTLY BEHIND THE LUMINAIRE. THE LUMINAIRE SHALL STILL USE THE DISTANCE TO THE NEAREST POINT(S) ON THE PROPERTY LINES TO DETERMINE THE REQUIRED BACKLIGHT RATING. 5.106.8.2 FACING - GLARE. FOR LUMINAIRES COVERED BY 5.106.8.1, IF A PROPERTY LINE ALSO EXISTS WITHIN OR EXTENDS INTO THE FRONT HEMISPHERE WITHIN 2MH OF THE LUMINAIRE THEN THE LUMINAIRE SHALL COMPLY WITH THE MORE STRINGENT GLARE RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE LIGHTING ZONE AND DISTANCE TO THE NEAREST POINT ON THE NEAREST PROPERTY LINE WITHIN THE FRONT HEMISPHERE 5.303.3.4.6 PRE-RINSE SPRAY VALVE. WHEN INSTALLED, SHALL MEET THE REQUIREMENTS IN THE CALIFORNIA CODE OF REGULATIONS, TITLE 20 (APPLIANCE EFFICIENCY REGULATIONS), SECTION 1605.1(h)(4) TABLE H-2, SECTION 1605.3(h)(4)(A), AND SECTION 1607(d)(7), AND SHALL BE EQUIPPED WITH AN INTEGRAL AUTOMATIC SHUTOFF. FOR REFERENCE ONLY: THE FOLLOWING TABLE AND CODE SECTION HAVE BEEN REPRINTED FROM THE CALIFORNIA CODE OF REGULATIONS, TITLE 20 (APPLIANCE EFFICIENCY REGULATIONS), SECTION 1605.1 (h)(4) AND SECTIONS 1605.3 (h)(4)(A). TABLE H2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALVES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [SPRAY FORCE IN OUNCE FORCE (OZF)] MAXIMUM FLOW RATE (GPM) PRODUCT CLASS 1 (≤5.0 OZF)1.00 PRODUCT CLASS 2 (> 5.0 OZF AND ≤8.0 OZF)1.20 PRODUCT CLASS 1 (> 8.0 OZF)1.28 TITLE 20 SECTION 1605.3(h)(4)(A): COMMERCIAL PRE-RINSE SPRAY VALVES MANUFACTURED ON OR AFTER JANUARY 1, 2006, SHALL HAVE A MINIMUM SPRAY FORCE OF NOT LESS THAN 4.0 OUNCES-FORCE (OZF) [113 GRAMS-FORCE (GF]. 5.504.4.4.1 CARPET CUSHION. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR CERTIFICATION PROGRAMS AND TESTING LABS. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLEB/IAQ/Pages/VOC.aspx #material SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEB- SITE FOR CERTIFICATION PROGRAMS AND TESTING LABS. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx# material SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR CERTIFICATION PROGRAMS AND TESTING LABS. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx# material 5.410.2.6 COMMISSIONING REPORT. 5.410.2.5.2 SYSTEMS OPERATIONS TRAINING. 5.410.2.5.1 SYSTEMS MANUAL. 5.410.2.5 DOCUMENTATION AND TRAINING. A SYSTEM MANUAL AND SYSTEMS OPERATIONS TRAINING ARE REQUIRED.INCLUDING OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) REQUIREMENTS IN CALIFORNIA CODE OF REGULATIONS. TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS TI SPECIFICATIONS TO COMPLY. THE SYSTEMS MANUAL SHALL BE DELIVERED TO THE BUILDING OWNER OR REPRESENTATIVE AND FACILITES OPERATOR AND SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2.5.1. A PROGRAM FOR TRAINING OF THE APPROPRIATE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND/OR SYSTEM SHALL BE DEVELOPED AND SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2.5.2. A REPORT OF COMMISSIONING PROCESS ACTIVITIES UNDERTAKEN THROUGH THE DESIGN AND CONSTRUCTION PHASES OF THE BUILDING PROJECT SHALL BE COMPLETED AND PROVIDED TO THE OWNER OR REPRESENTATIVE. TI SPECIFICATIONS TO COMPLY. TI SPECIFICATIONS TO COMPLY. TI SPECIFICATIONS TO COMPLY. DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 5 2 P M K. BURGER CB / JG SDG22-6057-00 CA L G R E E N N O T E S I0.6b CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 CALIFORNIA GREEN BUILDINGS STANDARDS CODE 2019 - NON-RESIDENTIAL MANDATORY MEASURES 5.507.4.3 INTERIOR SOUND TRANSMISSION WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES AND TENANT SPACES AND PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40. TI SPECIFICATIONS TO COMPLY. SECTION 5.508 OUTDOOR AIR QUALITY 5.508.1 OZONE DEPLETION AND GREENHOUSE GAS REDUCTIONS. INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL COMPLY WITH SECTIONS 5.508.1.1 AND 5.508.1.2. TI SPECIFICATIONS TO COMPLY. 5.508.1.1 CHLOROFLUOROCARBONS (CFCs). INSTALL HVAC AND REFRIGERATION EQUIPMENT THAT DOES NOT CONTAIN CFCS. TI SPECIFICATIONS TO COMPLY. 5.508.1.2 HALONS. SEE FIRE PROTECTION DRAWINGS - SUBMITTED UNDER SEPARATE PERMIT. INSTALL FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN HALONS. 5.508.2 SUPERMARKET REFRIGERANT LEAK REDUCTION. NEW COMMERCIAL REFRIGERATION SYSTEMS SHALL COMPLY WITH THE PROVISIONS OF THIS SECTION WHEN INSTALLED IN RETAIL FOOD STORES 8,000 SQUARE FEET OR MORE CONDITIONED AREA, AND THAT UTILIZE EITHER REFRIGERATED DISPLAY CASES, OR WALK- IN COOLERS OR FREEZERS CONNECTED TO REMOTE COMPRESSOR UNITS OR CONDENSING UNITS. THE LEAK REDUCTION MEASURES APPLY TO REFRIGERATION SYSTEMS CONTAINING HIGH-GLOBAL-WARMING POTENTIAL (HIGH-GWP) REFRIGERANTS WITH A GWP OF 150 OR GREATER. NEW REFRIGERATION SYSTEMS INCLUDE BOTH NEW FACILITIES AND THE REPLACEMENT OF EXISTING REFRIGERATION SYSTEMS IN EXISTING FACILITIES. SEE SUBSECTIONS OF SUBSECTION 5.508.2 FOR DETAILED REQUIREMENTS AND EXCEPTIONS. 5.507.4.1.1 NOISE EXPOSURE WHERE NOISE CONTOURS ARE NOT READILY AVAILABLE BUILDINGS EXPOSED TO A NOISE LEVEL OF 65 dB Leq-1-Hr DURING ANY HOUR OF OPERATION SHALL HAVE EXTERIOR WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MEETING A COMPOSITE STC RATING OF AT LEAST 45 (OR OITC 35), WITH EXTERIOR WINDOWS OF A MINIMUM STC OF 40 (OR OITC 30). TI SPECIFICATIONS TO COMPLY. 5.507.4.2 PERFORMANCE METHOD FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1 OR 5.507.4.1.1, WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT ATTRIBUTABLE TO EXTERIOR SOURCES THAT DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL (L eq - 1-Hr) OF 50 DBA IN OCCUPIED AREAS DURING ANY HOUR OF OPERATION. 5.507.4.2.1 SITE FEATURES EXTERIOR FEATURES SUCH AS SOUND WALLS OR EARTH BERMS MAY BE UTILIZED AS APPROPRIATE TO THE PROJECT TO MITIGATE SOUND MIGRATION TO THE INTERIOR. NO SITE WORK IS PROPOSED IN THIS PROJECT SCOPE. 5.507.4.2.2 DOCUMENTATION OF COMPLIANCE AN ACOUSTICAL ANALYSIS DOCUMENTING COMPLYING INTERIOR SOUND LEVELS SHALL BE PREPARED BY PERSONNEL APPROVED BY THE ARCHITECT OR ENGINEER OF RECORD. TI SPECIFICATIONS TO COMPLY. N/A SECTION 5.505 INDOOR MOISTURE CONTROL 5.505.1 INDOOR MOISTURE CONTROL TI SPECIFICATIONS TO COMPLY. SECTION 5.506 INDOOR AIR QUALITY 5.506.1 OUTSIDE AIR DELIVERY. TI SPECIFICATIONS TO COMPLY. 5.506.2 CARBON DIOXIDE (CO2) MONITORING. TI SPECIFICATIONS TO COMPLY. SECTION 5.507 ENVIRONMENTAL COMFORT 5.507.4 ACOUSTICAL CONTROL TI SPECIFICATIONS TO COMPLY. 5.507.4.1 EXTERIOR NOISE TRANSMISSION, PRESCRIPTIVE METHOD TI SPECIFICATIONS TO COMPLY. BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF CALIFORNIA BUILDING CODE, CCR, TITLE 24, PART 2, SECTIONS 1202 (VENTILATION) AND CHAPTER 14 (EXTERIOR WALLS) FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 (REQUIREMENTS FOR VENTILATION) OF THE CALIFORNIA ENERGY CODE, OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT, AND DIVISION 1, CHAPTER 4 OF CCR, TITLE 8. FOR BUILDINGS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CALIFORNIA ENERGY CODE, SECTION 120.1(c)(4). EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH STC VALUES DETERMINED IN ACCORDANCE WITH ASTM E 90 AND ASTM E 413 OR OUTDOOR-INDOOR SOUND TRANSMISSION CLASS (OITC) ITC DETERMINED IN ACCORDANCE WITH ASTM E 1332, USING EITHER THE PRESCRIPTIVE OR PERFORMANCE METHOD IN SECTION 5.507.4.1 OR 5.507.4.2. SEE SECTION 5.507 FOR EXCEPTIONS. WALL AND FLOOR-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION OR ALTERED ENVELOPE SHALL HAVE EXTERIOR WALL AND ROOF CEILING ASSEMBLIES MEETING A COMPOSITE STC RATING OF AT LEAST 50 OR A COMPOSITE OITC RATING OF NO LESS THAN 40 WITH EXTERIOR WINDOWS OF A MINIMUM STC 40 OR OITC OF 30 WITHIN THE 65 CNEL CONTOUR OF AN AIRPORT, FREEWAY, EXPRESSWAY, RAILROAD, INDUSTRIAL SOURCE OR FIXED -GUIDEWAY SOURCE. SEE THIS SECTION FOR FULL DESCRIPTION AND EXCEPTIONS. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITATIONS. SMOKING TO BE PROHIBITED IN SPECIFIC AREAS AS REQUIRED FOR TI SCOPE. SECTION 702 QUALIFICATIONS 702.2 SPECIAL INSPECTION. SECTION 703 VERIFICATIONS INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. WHEN SPECIFIC DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY COMPLIANCE, THAT METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE APPROPRIATE SECTION OR IDENTIFIED IN THE APPLICATION CHECKLIST. HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF HVAC SYSTEMS INCLUDING DUCTS AND EQUIPMENT BY A NATIONALLY OR REGIONALLY RECOGNIZED TRAINING OR CERTIFICATION PROGRAM. UNCERTIFIED PERSONS MAY PERFORM HVAC INSTALLATIONS WHEN UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF A PERSON TRAINED AND CERTIFIED TO INSTALL HVAC SYSTEMS OR CONTRACTOR LICENSED TO INSTALL HVAC SYSTEMS. EXAMPLES OF ACCEPTABLE HVAC TRAINING AND CERTIFICATION PROGRAMS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: 1. STATE CERTIFIED APPRENTICESHIP PROGRAMS 2. PUBLIC UTILITY TRAINING PROGRAMS 3. TRAINING PROGRAMS SPONSORED BY TRADE, LABOR, OR STATE-WIDE ENERGY CONSULTING OR VERIFICATION ORGANIZATIONS 4. PROGRAMS SPONSORED BY MANUFACTURING ORGANIZATIONS 5. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY BSC WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR TASK TO BE PERFORMED. IN ADDITION, THE SPECIAL INSPECTOR SHALL HAVE A CERTIFICATION FROM A RECOGNIZED STATE, NATIONAL OR INTERNATIONAL ASSOCIATION, AS DETERMINED BY THE LOCAL AGENCY. THE AREA OF CERTIFICATION SHALL BE CLOSELY RELATED TO THE PRIMARY JOB FUNCTION, AS DETERMINED BY THE LOCAL AGENCY. NOTE: SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR COMPLIANCE WITH THIS CODE. 702.1 INSTALLER TRAINING 703.1 DOCUMENTATION. DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 D D +60 D D D J J J J D D D D J J J J D D J J J J JJ J J D D D D D DD D D D D D J J F.E.C. F. E . C . F.E.C. F.E.C. INDICATES AREA NOT IN CONTRACT (N.I.C.) EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING CONSTRUCTION TO REMAIN N.I.C. TYP. D01 D03 D03 D03 D05 TYP. D06 TYP. D07 TYP. D08 TYP. D09 TYP. D10 D04 D11 TYP. D13 D14 D14 A002 A004 ± 3 ' - 0 " TYP. D02 ± 3'-4" ± 9"± 3'-4 1/2" ± 3'-4" 3'-4" ± 5 ' - 6 " 3' - 4 " 1' - 2 " ± 3 ' - 4 " ± 3'-4" TYP. D16 D17 TYP. D16 4' - 6 " D18 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 5 4 P M K. BURGER CB / JG SDG22-6057-00 DE M O L I T I O N F L O O R P L A N I1.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 0 4' 8'16' 32' 1/8"=1'-0" A002 PROVIDE PRICE ALTERNATE FOR EXISTING MILLWORK TO REMAIN, CLEAN AND REPAIR/REPLACE AS NEEDED FOR "LIKE NEW" CONDITION. A004 PROVIDE PRICE ALTERNATE FOR GC TO EVALUATE EXISTING HVAC CONDITIONS AT THIS ROOM. INTENT IS FOR ROOM TO REMAIN BELOW 80 DEGREES FAHRENHEIT. PROVIDE NEW AS REQUIRED TO MAINTAIN REQUIRED TEMPERATURE CONDITIONS. N DEMOLITION FLOOR PLAN NOTES LEGENDS DEMOLITION FLOOR PLAN KEYNOTES: • THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. SEE SHEETS I0.1 -I0.2 FOR GENERAL NOTES SCALE: 1/8" = 1'-0" 1DEMOLITION PLAN D01 REMOVE ALL WALL AND FLOOR FINISHES THROUGHOUT. PREP FOR NEW FINISHES PER FINISH PLAN. D02 DEMOLISH PORTION OF EXISTING WALL AS REQUIRED TO ACCOMMODATE NEW DOOR/CASED OPENING. D03 REMOVE EXISTING DOOR/FRAME AND SALVAGE FOR RE-USE. INFILL WALL TO MATCH ADJACENT CONSTRUCTION. D04 REMOVE EXISTING GLAZING AT THIS ROOM, DISPOSE OF AS REQUIRED, PATCH AND INFILL CONSTRUCTION PER NEW WALL LAYOUT. PROVIDE NEW DOOR FRAME AS REQUIRED. D05 EXISTING COLUMNS TO REMAIN. TYPICAL. D06 EXISTING BUILDING STANDARD MINI BLINDS TO REMAIN. PROTECT IN PLACE DURING CONSTRUCTION. REPAIR/REPLACE DAMAGED BLINDS WHERE NEEDED. D07 REMOVE EXISTING ONE-WAY MIRROR/WINDOW. INFILL WALL TO MATCH ADJACENT CONSTRUCTION. D08 EXISTING DOORS AND FRAMES TO REMAIN, U.O.N. NEW HARDWARE PER DOOR SCHEDULE (CORTICA STANDARD). D09 REMOVE EXISTING MILLWORK THROUGHOUT AND DISPOSE OF AS REQUIRED, U.O.N. CAP PLUMBING WHERE NEEDED. D10 REMOVE PARTITIONS AND RELATED ELECTRICAL OUTLETS AS INDICATED. TERMINATE ELECTRICAL LINES BACK TO POINT OF ORIGIN. D11 ALL EXISTING POWER/DATA/BLANK PLATES TO REMAIN, U.O.N. REPLACE COVERPLATES TO ALL EXISTING TO REMAIN. (D) DENOTES POWER/DATA/BLANK PLATE TO BE REMOVED. D13 DOORS/FRAMES TO BE REMOVED, SALVAGED, AND RELOCATED PER NEW FLOOR PLAN. NEW HARDWARE PER DOOR SCHEDULE (CORTICA STANDARD). GC TO EVALUATE DOORS FOR REUSE, PROVIDE NEW TO MATCH EXISTING AS NECESSARY. D14 EXISTING MILLWORK TO REMAIN, PREP TO BE RE-FACED PER CORTCA STANDARD FINISHES. D16 DEMOLISH EXISTING PLUMBING FIXTURES/ACCESSORIES U.O.N. PREP TO RECEIVE NEW WHERE OCCURS. CAP PLUMBING WHERE NEEDED. D17 EXISTING TAMPON DISPENSER TO REMAIN, PROTECT. D18 EXISTING POWER TO BE MODIFIED TO ACCOMMODATE NEW MILLWORK DESIGN. SEE ELEVATIONS AND POWER PLAN FOR MORE INFORMATION. ALTERNATES DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 J J J J J J J J J J J J JJ J J J J JD INDICATES AREA NOT IN CONTRACT (N.I.C.) EXISTING SUSPENDED CEILING GRID & TILES TO REMAIN EXISTING SUSPENDED CEILING GRID & TILES TO BE REMOVED EXISTING 2'x4' LIGHT FIXTURE TO BE REMOVED EXISTING 2'x2' LIGHT FIXTURE TO BE REMOVED EXISTING CEILING-MOUNTED EXIT SIGN TO BE REMOVED EXISTING WALL-MOUNTED EXIT SIGN TO BE REMOVED D D EXISTING GYPSUM BOARD CEILING TO REMAIN EXISTING PENDANT TO BE REMOVED EXISTING LINEAR PENDANTS TO BE REMOVED EXISTING PENDANT TO BE REMOVED EXISTING PENDANT TO BE REMOVED D51 TYP. D53 D51 TYP. D53 TYP. D52 TYP. D54 TYP. D54 D55 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 4 : 5 8 P M K. BURGER CB / JG SDG22-6057-00 DE M O L I T I O N C E I L I N G P L A N I1.1a CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 D51 REMOVE ALL LIGHTING TYPICAL THROUGHOUT, REPLACE FIXTURES IN PLACE (AS APPLIES) PER NEW CEILING PLAN, INFILL CEILING TILES WHERE NEEDED. D52 EXISTING CEILING POWER/DATA TO REMAIN THROUGHOUT. G.C. TO CONFIRM FUNCTIONALITY, TERMINATE ELECTRICAL LINES BACK TO POINT OF ORIGIN WHERE APPLICABLE. D53 EXISTING CEILING GRID AND TILE TO REMAIN THROUGHOUT, U.O.N. PATCH AND INFILL AT AREAS OF DEMO AS NEEDED. D54 REMOVE ALL ABANDONED CEILING, MECHANICAL, AND ELECTRICAL ELEMENTS AND PREP FOR NEW PER REFLECTED CEILING PLAN. D55 EXISTING CEILING MOUNTED REFLECTIVE DOMES TO REMAIN, PROTECT IN PLACE. KEYNOTES: DEMOLITION CEILING PLAN NOTES LEGENDS DEMOLITION CEILING PLAN • THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. SEE SHEETS I0.1 -I0.2 FOR GENERAL NOTES SCALE: 1/8" = 1'-0"1DEMOLITION REFLECTED CEILING PLAN 0 4' 8'16' 32' 1/8"=1'-0"N DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 R CR CR CR CR F.E.C. F. E . C . F.E.C. CR CR F.E.C. CR EXISTING WALL BASIC DESCRIPTIONWALL FULL HEIGHT NON-RATED PARTITION TO STRUCTURE PARTITION TO 6" ABOVE CEILING LOW WALL PARTITION INDICATES AREA NOT IN CONTRACT (N.I.C.) N.I.C. CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150D OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 209 218 218 246 215 210 204 213 223 206 205 225 222 TYP. 203 211 ± 24'-11" 233 233 233 212 214 214 TYP. 244 221 249 249 227 227 227 TYP. 228 226 226 TYP. 208 212 231 231 229 229 A003 TYP. 250 TYP. 251 144 158 143 142 150b 141 140 139 138 137 136 150a 150c 149148 150d 104 105 151 152 153 154 155156 157 135 134 132 133 106 107 108 109 110 111 112 113 114 115 116 126 125 124 123 122121 120119118 117 163 164 128 129 130 131 HALLWAY 158 HALLWAY 159 HALLWAY 160 HALLWAY 161 HALLWAY 162 HALLWAY 163 HALLWAY 164 I6.2 1A I6.1 1 231 ± 7'-6 1/2" 6'-8" 3' - 0 " CLR 5'-0" 9'-11"9'-6" 8'-7" 8'-7" TYP. 232 ± 11 ' - 8 " HOLD 6'-4 " ± 7'-9" 8 1/2" 252 I6.3 2 TYP. 3' - 0 " I6.3 1A1B 3' - 1 0 " 9'-0"9'-0" 8'- 7 " CLEAR 5'-0" 6' - 1 0 " 7'- 2 " I6.36 233 I6.33 I6.3 4I6.3 7 I6.3 8 1C 209 I6.3 5 TYP. 253 TYP. 253 TYP. 253 161 100 231 CLEAR 5'-0"EQ.EQ. 209 TYP. 2'-0 " ± 4 ' - 4 " 255 1 147 127 2B 2D 254 254 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 0 3 P M K. BURGER CB / JG SDG22-6057-00 FL O O R P L A N I2.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 203 ALL WALLS TO BE INSULATED WITH R-11, UNFACED FIBERGLASS INSULATION. 204 NEW UPPER AND LOWER CABINETRY WITH DRAWERS, 8" BAR PULLS, DOUBLE-BASIN STAINLESS STEEL SINK WITH GARBAGE DISPOSAL AND INSTA-HOT. SEE NOTE ON FINISH PLAN FOR MORE INFORMATION. 205 NEW REFRIGERATOR TO BE PROVIDED BY TENANT AND INSTALLED BY G.C. PROVIDE RECESSED WATER LINE FOR ICE MAKER. 206 NEW MICROWAVE TO BE PROVIDED AND INSTALLED BY G.C. MICROWAVE TO BE ACCESSIBLE. 208 EXISTING FIRE EXTINGUISHER CABINETS TO REMAIN, GC TO CONFIRM FIRE EXTINGUISHER IS FUNCTIONAL AND REPLACE IF NEEDED WITH BUILDING STANDRD SPEC. 209 FLATSCREEN TV TO BE PROVIDED BY TENANT AND INSTALLED BY G.C. PROVIDE BACKING/ADDITIONAL SUPPORT AS REQUIRED. CONFIRM SIZE AND LOCATION WITH TENANT. 210 PROVIDE PLASTIC LAMINATE FLOATING COUNTER WITH IN-WALL BRACKET SUPPORTS, SEE ELEVATION FOR MORE INFORMATION. 211 PROVIDE TEMPERED CLEAR GLASS BUTT-JOINED FIXED WINDOW IN FRAME TO MATCH DOOR FRAMES. BOTTOM OF FRAME TO BE AT 3'-6" A.F.F. ALIGN TOP OF FRAME WITH TOP OF NEW DOOR FRAME. GLASS TO RECEIVE PRIVACY FILM, SPEC: 3M MILANO FROST. PROVIDE SAMPLE FOR REVIEW AND APPROVAL. 212 PROVIDE PLASTIC LAMINATE LOWER AND UPPER CABINTRY WITH SINK AND FULL HEIGHT CABINET. SEE ELEVATION FOR MORE INFORMATION 213 COFFEE MAKER TO BE PROVIDED AND INSTALLED BY TENANT. PROVIDE RECESSED WATER LINE. CONFIRM LOCATION WITH TENANT PRIOR TO INSTALLING WATER LINE. 214 SAW-CUT CONCRETE FLOOR THIS AREA AS REQUIRED FOR NEW PLUMBING. 215 PROVIDE DOUBLE STUD FULL-HEIGHT WALL. SEE DETAIL 18/A8.1 FOR MORE INFORMATION. 218 PROVIDE 30" WIDE X 30" HIGH PLASTIC LAMINATE WORK COUNTER WITH BUILT-IN WALL BRACKETS. COORDINATE GROMMET LOCATION WITH TENANT. 221 TENANT LOGO (SIGNAGE BY OTHERS VERIFY BACKING/EQUIPMENT NEEDED). 222 TENANT TO PROVIDE OPEN OFFICE EQUIPMENT AND FURNITURE. 223 PROVIDE EXTRA HOT WATER AT BREAK SINK. 225 NEW PLASTIC LAMINATE UPPER AND LOWER CABINETRY WITH DRAWERS AND 8" BAR PULLS, PLASTIC LAMINATE COUNTER AND 4" BACKSPLASH. 226 NEW PLASTIC LAMINATE UPPER AND LOWER CABINETRY WITHOUT DRAWERS, 8" BAR PULLS. NO BACKSPLASH. 227 MODIFY EXISTING WALLS IN THIS ROOM TO BE FULL HEIGHT, FULLY INSULATED (OPEN TO DECK CONDITION). 228 EXISTING BUILDING STANDARD MINI BLINDS TO REMAIN. PROTECT IN PLACE DURING CONSTRUCTION. REPAIR/REPLACE DAMAGED BLINDS WHERE NEEDED. 229 GC TO CONFIRM NEW AREA OF DEMISING WALL IS FULLY INSULATED, WALL TO EXTEND TO CEILING DECK. 231 REFER TO ENLARGED PLAN FOR ADDITIONAL INFORMATION. 232 INFILL WALL WHERE AFFECTED BY DEMOLITION. MATCH ADJACENT CONSTRUCTION. 233 EXISTING DOOR ASSEMBLY TO REMAIN. PROVIDE CARD READER & RETROFIT DOORS AS NEEDED. 244 PROVIDE ROOM SIGNAGE ADJACENT TO DOORS THROUGHOUT. COORDINATE DESIGN AND TEXT WITH TENANT AND SIGNAGE VENDOR. 246 THIS DOOR TO BE PLAIN SLICED WALNUT VENEER WITH CLEAR COAT. SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION. 249 GC TO PROVIDE FENCE AT OPENING TO SECURE OUTDOOR PATIO. 250 REFER TO DOOR SCHEDULE FOR EXISTING OR RELOCATED DOORS TO BE MODIFIED TO HAVE 8"X36" VISION PANEL (CORTICA STANDARD). PROVIDE NEW DOORS AS NEEDED. 251 PROVIDE METAL CORNER GUARD AT ALL CORNERS IN HALLWAYS. TENANT TO PROVIDE SPECS. 252 PROVIDE TEMPERED CLEAR GLASS BUTT-JOINED FIXED WINDOW IN FRAME TO MATCH DOOR FRAMES. ALIGN TOP OF FRAME WITH TOP OF DOOR FRAME. GLASS TO EXTEND FULL LENGTH OF ROOM. 253 G.C. TO EVALUATE SALVAGED DOORS/FRAMES FOR RE-USE/RELOCATION. PROVIDE NEW AS REQUIRED. 254 EXISTING MILLWORK TO BE REFACED PER CORTICA FINISH STANDARDS. REFER TO FINISH PLAN FOR SPECIFCATIONS. 255 PATCH AND REPAIR THROUGHOUT WHERE AFFECTED BY DEMOLITION. 1. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. 2. CONTRACTOR SHALL NOTIFY ARCHITECT TO PERFORM AN ON-SITE REVIEW ONCE ALL PARTITIONS HAVE BEEN LAID OUT, PRIOR TO ERECTING THE PARTITIONS, AND ADDRESS ANY DISCREPANCIES WITH DIMENSIONS SHOWN ON THE CONTRACT DOCUMENTS. 3. ALL METAL WALL STUDS TO BE 3-5/8" DEPTH - GAUGE AND SPACING PER L/240 SPAN TABLE, ON THE FRAMING DETAILS SHEET, U.O.N. 4. ALL RESTROOM WALL STUDS AT SINGLE-STUD RESTROOM WET-WALLS TO BE MINIMUM 6" DEEP, AND FULLY INSULATED WITH R-13 UNFACED FIBERGLASS INSULATION (OR EQUIVALENT), U.O.N. 5. ALL NEW INTERIOR PARTITIONS TO BE FULLY INSULATED WITH A MINIMUM OF R-11 UNFACED FIBERGLASS INSULATION (OR EQUIVALENT), U.O.N. 6. DRYWALL GYPSUM BOARD SHALL BE FINISHED AS FOLLOWS, U.O.N. REFER TO GYPSUM ASSOCIATION PUBLICATION, GA-214 (https://www.certainteed.com/drywall/what-are- recommended-levels-finish/): a. FOR PLENUM AND NON-VISIBLE AREAS –LEVEL-1. AREAS WITH OPEN-CEILINGS OR CLOUDS TO BE FINISHED AS FOR VISIBLE PARTITIONS. b. BEHIND WALL TILE –LEVEL-2 c. ALL VISIBLE PARTITION SURFACES –LEVEL 4, UNLESS NOTED AS LEVEL-5 BY OTHER NOTES OR KEYED NOTE. 7. PROVIDE DRYWALL EXPANSION & CONTROL JOINTS PER “WALL AND CEILING BUREAU” (WCB) STANDARDS. PROVIDE SHOP DRAWINGS FOR REVIEW PRIOR TO INSTALLATION. 8. ALL DRYWALL CORNERS AND COLUMN EDGES TO BE FINISHED WITH CORNER "L" BEAD. 9. DIMENSIONS OF COLUMN FURRING IN A COMMON AREA ARE TO BE EQUAL & CONSISTENT. 10. PATCH AND REPAIR ANY DAMAGE TO EXISTING WINDOW SILLS CAUSED BY DEMOLITION: MATCH EXISTING SILL CONDITION. FINISH TO MATCH EXISTING WINDOW FRAMES. 11. ACCESS PANELS IN WALLS/CEILINGS FOR PLUMBING, MECHANICAL, AND ELECTRICAL ACCESS SHALL BE FLUSH FRAMELESS GYPSUM BOARD PANELS. 12. EXTEND EXISTING GYPSUM BOARD PARTITIONS/FURRING TO UNDERSIDE OF STRUCTURE IN AREAS OF OPEN CEILINGS. 13. ALL BLOCKING IN WALL TO BE FIRE RETARDANT TREATED SOLID WOOD BLOCKING, OR CONTINUOUS METAL STRAPPING. COORDINATE EXACT LOCATIONS AND EXTENT IN FIELD. GC TO PROVIDE BLOCKING FOR ALL OWNER SUPPLIED MILLWORK, IN ADDITION TO MILLWORK SUPPLIED BY THE GC, AND WALL HUNG EQUIPMENT. 14. FOR WALL MOUNTED TELEVISIONS, PROVIDE BLOCKING IN WALLS AS APPROPRIATE FOR MOUNTING TYPE. COORDINATE WITH A/V SPECIFICATIONS & REQUIREMENTS. KEYNOTES: FLOOR PLAN NOTES WALL LEGEND LEGEND SEE SHEETS I0.1 -I0.2FOR GENERAL NOTES SCALE: 1/8" = 1'-0" 1FIRST FLOOR PARTITION PLAN 0 4' 8'16' 32' 1/8"=1'-0"N ALTERNATES A003 PROVIDE PRICE ALTERNATE TO PROVIDE ADDITIONAL LAYER OF GYP ON EACH SIDE AT NEW DEMISING WALL. DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 R J J J J J J J J J J J JJ J J J J N N N N NN N N N N N N N N N N N N N N N N N N N N N N N N N N NN N GF I ( N ) TVN N N CR CR CR CR F.E.C. F. E . C . F.E.C. CR CR TVN N N F.E.C. J TV N N N GFI (N) CR N N N N J DEDICATED 110v./20 AMP DUPLEX RECEPTACLE, MOUNTED VERTICALLY AT +18" A.F.F., U.O.N. 110v. DUPLEX RECEPTACLE, MOUNTED 6" ABOVE COUNTER OR SPLASH. 110v. FOURPLEX RECEPTACLE, MOUNTED AT +18" A.F.F., U.O.N. DEDICATED 110v./20 AMP FOURPLEX RECEPTACLE, MOUNTED AT +18" A.F.F., U.O.N. DATA OUTLET MUD RING, WALL-MOUNTED AT 18" A.F.F., U.O.N. PROVIDE PULL ROPE TO ABOVE ACCESSIBLE CEILING SPACE. COMBINATION TELEPHONE/DATA OUTLET MUD RING, WALL-MOUNTED AT 18" A.F.F., U.O.N. PROVIDE PULL ROPE TO ABOVE ACCESSIBLE CEILING SPACE. COMBINATION 110v. DUPLEX RECEPTACLE/DATA OUTLET, MOUNTED FLUSH IN FLOOR BOX WITH FITTINGS. PROVIDE RATING AS REQUIRED. "P" DESIGNATES PEDESTAL TYPE JUNCTION BOX, CEILING-MOUNTED (IN ACCESSIBLE CEILING) WITH FLEXIBLE CONNECTION TO PRE-WIRED FURNITURE SYSTEM. COMBINATION TELEPHONE/DATA OUTLET, CEILING-MOUNTED (IN ACCESSIBLE CEILING) WITH FLEXIBLE CONNECTION TO PRE-WIRED FURNITURE SYSTEM. VERIFY CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER PRIOR TO ROUGH-IN. 110v. DUPLEX RECEPTACLE, MOUNTED VERTICALLY AT +18" A.F.F., U.O.N. "C" DESIGNATES RECESSED TYPE SOCKET. CR ***(N) DENOTES NEW. ELECTRICAL ITEMS ARE EXISTING TO REMAIN, UO.N. WALL-MOUNTED JUNCTION BOX FOR CARD READER AT 48" A.F.F., U.O.N. PROVIDE 3/4" CONDUIT WITH PULL STRING & PULL RING STUBBED 6" INTO ACCESSIBLE CEILING SPACE. LOW VOLTAGE WIRING & CARD READER FURNISHED BY TENANT: OP-R2-STN STANDARD SMART READER V2 BY OPENPATH TV SINGLE COAX JACK. PROVIDE CONDUIT FOR HDMI CABLE FROM CABLE BOX TO MONITOR, MOUNTED AT +60" A.F.F., U.O.N. N.I.C. CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150D OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 309 312 312 312 316 316 316 316 314 TYP. 303 +60" (X2) +60" (X2) TYP. 301 TYP. 301 TYP. 301 306 304 317 +60" 316 316 GFI 318 +24" 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 0 6 P M K. BURGER CB / JG SDG22-6057-00 PO W E R & S I G N A L P L A N I3.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 301 ALL FURNITURE TO BE PROVIDED AND INSTALLED BY TENANT. VERIFY EXACT LOCATIONS AND ELECTRICAL REQUIREMENTS WITH FURNITURE DEALER PRIOR TO INSTALLATION OF RELATED POWER & SIGNAL CONNECTIONS. 303 ALL OUTLETS AT OR NEAR ANY WATER SOURCE TO BE G.F.I. 304 CORE DRILL EXISTING CONCRETE FLOOR AT THIS AREA AS REQUIRED FOR NEW FLOOR CORE. NEW FLOOR BOX TO BE COMPLETELY FLUSH AND ACCEPT FLOOR SURFACE FOR CONCEALED LOOK. PROVIDE (1) 1/2" CONDUIT FOR POWER/DATA/AV/HDMI. VERIFY EXACT LOCATION WITH TENANT PRIOR TO SAW-CUTTING. 306 FLOOR OUTLETS TO BE CENTERED IN THIS ROOM. VERIFY FINAL LOCATION WITH TENANT/TENANT VENDOR. 309 VERIFY POWER REQUIREMENTS FOR USER PROVIDED EQUIPMENT IN THIS ROOM PRIOR TO INSTALLATION OF RELATED POWER AND SIGNAL CONNECTIONS. TENANT RACK TO BE LOCATED IN THIS ROOM. 312 PROVIDE CEILING NETWORK DROP FOR WIRELESS ACCESS POINT AT THIS LOCATION. 314 PROVIDE 48"X48" PLYWOOD BACKBOARD, BOTTOM OF BACKBOARD TO BE AT 36"A.F.F. WITH DEDICATED QUAD 60"A.F.F. 316 PROVIDE CARD READER AT THIS EXISTING DOOR. CONFIRM REQUIREMENTS WITH TENANT SECURITY VENDOR. LANDLORD TO PROVIDE BOX, TENANT TO PROVIDE CARD READERS AND ACCESS CONTROL SYSTEM. 317 PROVIDE J-BOX AT UNDERSIDE OF STRUCTURE FOR CEILING MOUNTED TV. COORDINATE FINAL LOCATION AND POWER REQUIREMENTS WITH TENANT AND AV VENDOR. PROVIDE ADDITIONAL SUPPORT AS REQUIRED FOR CEILING MOUNTED EQUIPMENT. 318 CONFIRM EXISTING POWER/DATA IS SUFFICIENT FOR TENANT NEEDS. ADJUST AS REQUIRED. POWER & SIGNAL PLAN NOTES LEGEND KEYNOTES: SEE SHEETS I0.1 -I0.2FOR GENERAL NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. 2. ARCHITECTURAL DIMENSIONS AND LOCATIONS TAKE PRECEDENCE. SEE ELECTRICAL DRAWINGS FOR COORDINATION, IF INCONSISTENCIES OCCUR CONTACT ARCHITECT FOR CLARIFICATION. 3. INDICATED DIMENSIONS ARE TO CENTERLINE OF DEVICE OR CLUSTER UNLESS OTHERWISE NOTED. 4. OUTLETS ON OPPOSITE SIDES OF A PARTITION SHALL NOT BE BACK-TO-BACK: OFFSET TO ALLOW INSULATION BETWEEN. 5. VERIFY POWER REQUIREMENTS FOR USER PROVIDED EQUIPMENT. 6. ALL FURNITURE TO BE PROVIDED AND INSTALLED BY TENANT. LAYOUT SHOWN FOR REFERENCE. VERIFY EXACT LOCATIONS OF FLOOR CONNECTIONS/DEVICES WITH FURNITURE DEALER PRIOR TO INSTALLATION OF RELATED POWER AND SIGNAL CONNECTIONS. 7. COORDINATE EXACT OUTLET LOCATIONS IN FIELD WITH SECURITY, AUDIO-VISUAL, INFORMATION TECHNOLOGY, AND EQUIPMENT VENDORS RESPECTIVELY. 8. GANG MULTIPLE ADJACENT OUTLETS AND SWITCHES TOGETHER WITH MULTI-OUTLET COVER PLATE, U.O.N. 9. ALL SWITCHES/MOTION SENSORS SHALL NOT BE PLACED BEHIND DOORS WHEN IN OPEN POSITION. 10. PROVIDE CONDUIT(S) IN CONFERENCE AND TRAINING ROOMS BETWEEN FLOOR OUTLETS/DATA/HDMI AND ASSOCIATED EQUIPMENT ON WALL AND/OR CEILING SUCH AS TV’S, RECESSED SCREENS, AND PROJECTORS. GC TO PROVIDE A MINIMUM OF TWO CONDUITS BETWEEN EACH FLOOR OUTLET AND PIECE OF EQUIPMENT. VERIFY FINAL SIZES WITH A/V VENDOR AND CLIENT FOR POWER CONDUIT AND DATA CONDUIT. 11. CONTRACTOR TO REFER TO DOOR SCHEDULE FOR ANY ELECTRIFIED HARDWARE (I.E. FOR CARD READERS, OR OTHER ACCESS CONTROL, ETC). 12. WHERE RECEPTACLES ARE WITHIN MILLWORK, GC IS RESPONSIBLE TO COORDINATE WITH ELECTRICAL & MILLWORK TRADES. 13. WHERE GARBAGE DISPOSALS ARE INDICATED, PROVIDE SEPARATE SWITCH ABOVE THE COUNTER. 14. ALL EXISTING BLANK PLATES AND ASSOCIATED WIRING TO BE REMOVED TO CLOSEST JUNCTION BOX. PATCH HOLE, TAPE, AND PROVIDE NEW SMOOTH SURFACE FOR PAINTED FINISH. 15. PRIOR TO CORING OR SAW CUTTING, X-RAY OR IMAGE AREA OF WORK FOR AVOIDANCE OF REBAR OR OTHER CONCEALED ITEMS. REVIEW FINAL LOCATIONS WITH ARCHITECT AND OWNER. 16. NEW DATA CABLING TO BE SUPPLIED AND INSTALLED BY TENANT. SCALE: 1/8" = 1'-0" 1POWER & SIGNAL PLAN 0 4' 8'16' 32' 1/8"=1'-0"N DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 J J J J J J J J J J J JJ J J J J J EXISTING 2X2 ACT AND GRID AT ±9'-10" A.F.F. PATCH AND REPAIR AS NEEDED. AREA OF NEW GYP. BD. CEILING OR SOFFIT. DIMENSIONS PER PLAN. RECESSED 4" LED DOWNLIGHT SPEC: MAXILUME BY ELITE LIGHTING HH4-LED-2000L-35K-HH4-4501-CL-WH 2'X2' RECESSED LED FIXTURE (BUILDING STANDARD OR APPROVED EQUAL) MFR: LITHONIA LIGHTING MODEL: BLT SERIES 2'X2' LED 5" DIA. PENDANT. SPEC: CSL LPF-35, COLOR: WHITE NOTE: ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED PRIOR TO FINAL INSPECTION AND SUBJECT TO BUILDING INSPECTOR. CEILING-MOUNTED EXIT SIGN WITH BATTERY BACKUP, SHADED QUADRANT INDICATES FACE OF LETTERING, SIGN TO INCLUDE DIRECTIONAL ARROW AS INDICATED. WALL-MOUNTED EXIT SIGN WITH BATTERY BACKUP, SHADED QUADRANT INDICATES FACE OF LETTERING, SIGN TO INCLUDE DIRECTIONAL ARROW AS INDICATED. NEW 2" LINEAR SUSPENDED LED LIGHT FIXTURE SPEC: ELITE LIGHTING OLS-DI-LED-2-S-4'-D500L-U1000L-2C-DIMC10-35K-SI-OCGS COLOR: SILVER 24" DIA. DECORATIVE PENDANT LIGHT FIXTURE. SPEC: WAC LIGHTING, VIDA MODEL PD72724-AL 2'X4' RECESSED LED FIXTURE (BUILDING STANDARD OR APPROVED EQUAL) MFR: LITHONIA LIGHTING MODEL: BLT SERIES 2'X4' LED F1 F2 F3 F4 F6 NEW 2" LINEAR SUSPENDED LED LIGHT FIXTURE SPEC: ELITE LIGHTING OLS-DI-LED-2-S-6'-D500L-U1000L-2C-DIMC10-35K-SI-OCGS COLOR: SILVER PROVIDE MANUFACTURERE'S SUSPENSION HARDWARE F7 F8 NEW 2X2 ACT AND GRID ASSEMBLY AT ±9'-10" TO MATCH EXISTING SPECIFICATIONS. TIE INTO EXISTING GRID ASSEMBLY WHERE APPLIES FOR SEAMLESS TRANSITION. CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150D OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 F3 F3 F3 F3 F3 F4 F4 F4 F4 F4 F8 F4 F4 F8 F4 F4 F4 F3 F3 F3 F3 F3 F3 F3 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F7 F7 F7 406 406 F7 F3 F3 F3 F3 F3 F3 F3 F3 TYP. 404 403 403 403 A004 9'-10" TYP. 434 9'-0" 9'-0" 9'-0" EQ EQ . 5 ' - 0 " EQ . 4' - 0 " 4' - 0 " 2' - 2 " 5' - 0 " EQ EQ 8'-0" 8'-0" 6'-0" 2'-11" 3'-1" 5'-2" 1'-9" 7' - 7 " 7' - 7 " 7' - 7 " 2 ' - 7 " 1' - 7 " 1' - 7 " I6.2 1B EQ . 8'- 0 " 8'- 0 " EQ . 5'-9" 10'-0" 10'-0" 10'-0" 10'-0" 434 6'-0" 12 ' - 0 " 438 HALLWAY 158 HALLWAY 159 HALLWAY 160 HALLWAY 161 HALLWAY 162 HALLWAY 163 HALLWAY 164 8'-10" 14 I8.2 TYP. 20 I8.2 TYP. 435 TYP. 435 435 4' - 3 1 / 2 " 7 ' - 0 " 7' - 0 " 4 ' - 3 1 / 2 " EQ EQ EQ EQ EQ EQ 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 1 2 P M K. BURGER CB / JG SDG22-6057-00 RE F L E C T E D C E I L I N G P L A N I4.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 403 PROVIDE ADDITIONAL SUPPORT FROM EXISTING STRUCTURE FOR TENANT PROVIDED EQUIPMENT. COORDINATE LOCATION WITH TENANT PRIOR TO INSTALLATION. 404 EXISITNG GRID AND TILE TO REMAIN THROUGHOUT. REWORK PER NEW WALL LAYOUT AND REPLACE/MODIFY AS NEEDED . 406 PROVIDE METAL STUDS AND GYPSUM BOARD SOFFIT TO TOP OF UPPER CABINETRY. 435 PATCH AND REPAIR EXISTING CEILING WHERE AFFECTED BY DEMOLITION AND NEW CONSTRUCTION. 438 DENOTES LOCATION OF CEILING MOUNTED J-BOX FOR CEILING MOUNTED TV. A004 PROVIDE PRICE ALTERNATE FOR GC TO EVALUATE EXISTING HVAC CONDITIONS AT THIS ROOM. INTENT IS FOR ROOM TO REMAIN BELOW 80 DEGREES FAHRENHEIT. PROVIDE NEW AS REQUIRED TO MAINTAIN REQUIRED TEMPERATURE CONDITIONS. CEILING PLAN NOTES LEGEND KEYNOTES: SEE SHEETS I0.1 -I0.2FOR GENERAL NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. 2. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS BEFORE PROCEEDING WITH INSTALLING THE WORK. 3. SEE FIXTURE SCHEDULE FOR FIXTURE TYPE DESIGNATIONS, AND TYPICAL MOUNTING HEIGHTS (U.O.N). COORDINATE MOUNTING OPTIONS WITH OWNER’S REPRESENTATIVE & ARCHITECT. NOTIFY OWNER/ARCHITECT OF ANY CONFLICTS WITH OTHER ELEMENTS PRIOR TO INSTALLATION. 4. ALL MATERIALS USED WITHIN CEILING PLENUM SHALL BE NON-COMBUSTIBLE. 5. IN GYPSUM BOARD CEILINGS THE LIGHTS, HVAC ELEMENTS, FIRE DEVICES, ETC. ARE TO ALIGN IN A NEAT AND REGULAR PATTERN. REVIEW LAYOUT WITH ARCHITECT PRIOR TO ROUGH-IN. 6. DEVICES IN ACOUSTICAL CEILING TILES TO BE CENTERED IN A 2'X2' TILE, OR 2'X2' PORTION OF A 2'X4' TILE, U.O.N. 7. GENERAL CONTRACTOR TO IDENTIFY QUANTITY AND LOCATIONS OF ALL ACCESS PANELS TO CEILING PLENUM SPACES IN GYPSUM BOARD CEILINGS: ACCESS PANELS TO BE AVOIDED WHERE POSSIBLE. IF AN ACCESS PANEL IS REQUIRED, COORDINATE LOCATION WITH ARCHITECT. CEILING ACCESS PANELS TO BE FLUSH FRAMELESS GYPSUM-BOARD INFILL PANELS. 8. SEE KEYNOTE INFORMATION FOR ANY REQUIRED CEILING INSULATION. 9. ALL ACOUSTICAL CEILING GRIDS & TILE TO BE CENTERED WITHIN A ROOM, U.O.N. 10. WHERE LIGHTING IS WITHIN MILLWORK OR WALL ELEMENTS SUCH AS MIRRORS, GC IS RESPONSIBLE TO COORDINATE WITH ALL ELECTRICAL TRADES. SEE SHEET I2.0 FOR FINISH, PLUMBING FIXTURES, RESTROOM ACCESSORIES, EQUIPMENT AND LIGHT FIXTURE SCHEDULES SCALE: 1/8" = 1'-0" 1REFLECTED CEILING PLAN 0 4' 8'16' 32' 1/8"=1'-0"N DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L ALTERNATES 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 R F.E.C. F. E . C . F.E.C. F.E.C. CR N.I.C. CONSULT 147 CONSULT 148 CONSULT 149 WAITING 100 RECEPTION 101 COPY/PRINT 103 UNISEX RR 146 UNISEX RR 145 UNISEX RR 100A PANTRY 144A STAFF BREAK 144 PHONE 143 OFFICE 104 OFFICE 105 CONFERENCE 106 OFFICE 107 OFFICE 108 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 115 STORAGE 109 IT/SERVER 110 OFFICE 114 OFFICE 113 OFFICE 142 OFFICE 141 OFFICE 140 OFFICE 139 OFFICE 138 OFFICE 137 OFFICE 136 OFFICE 157 CONSULT 151 STORAGE 150D OFFICE 152 OFFICE 156 OFFICE 155 TELEHEALTH 154 TELEHEALTH 153 OFFICE 112 STORAGE 111 OFFICE 131 OFFICE 130 OFFICE 129 OFFICE 128 OFFICE 127 OFFICE 126 OFFICE 125 OFFICE 123 TRAINING 116 OFFICE 124 OFFICE 121 OFFICE 122 OPEN OFFICE 150 OFFICE 135 OFFICE 134 OFFICE 132 OFFICE 133 CHECK OUT 102 LVT 1 VCT 1 C 1 LVT 1 LVT 1 P 1 RB 1 C 1 TYP. P 5 P 5 P 5 P 4 P 4 P 3 P 3 P 2 P 2 P 2 P 2 P 2 P 3 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 2 P 3 P 2 P 2 P 2 P 2 P 2 P 2P 2 P 5 P 5 P 5 P 4 P 5 P 4 P 2 P 2 P 2 P 2 P 2 P 4 P 4 P 5 P 5 P 5 LVT 1 P 7 P 7 PFT 1 PFT 1 PFT 1 P 4 P 4 504 503 503 501 TYP. 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502 502502 502 502 502 509 509 503 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 1 7 P M K. BURGER CB / JG SDG22-6057-00 FI N I S H P L A N I5.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 501 ALL ROOMS TO RECEIVE PAINT, 4" RUBBER BASE AND CARPET (C-1), U.O.N. 502 PAINT FINISH AT THIS LOCATION/ROOM TO BE SEMI-GLOSS. 503 DECK, MECHANICAL UNIT / DUCTS, PIPES AND WIRES TO RECEIVE PAINT P-1 (FLAT FINISH) AT OPEN CEILING AREA. 504 PAINT ON THIS WALL TO BE TEXTURED WITH ANTI-SKID FINISH. SPEC: SEAL KRETE FLOOR-TEX, TEXTURED CONCRETE FLOORING. 509 EXISTING MILLWORK TO BE REFACED PER CORTICA STANDARDS. PL-2 ON VERTICAL SURFACES, PL-1 FOR COUNTERS. FINISH PLAN NOTES KEYNOTES: SEE SHEETS I0.1 -I0.2FOR GENERAL NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. 2. CONTRACTOR TO INCLUDE ALL FLOOR PREPARATIONS IN BASE BID. 3. SEE ENLARGED PLANS, ELEVATIONS AND DETAILS FOR ADDITIONAL FINISH INFORMATION. 4. PREPARE WALLS TO RECEIVE (2) COATS EGGSHELL PAINT, U.O.N. 5. PROVIDE LEVEL 5 FINISH FOR WALLS UNDER SKYLIGHTS & AT WALL-WASH LIGHT FIXTURES. 6. COORDINATE WITH OTHER TRADES AT LOCATIONS OF SPECIALTY WALL FINISHES, BRANDING OR SIGNAGE FOR SPECIFIC WALL PREP. 7. ALL AREAS WITHIN PROJECT BOUNDARY TO RECEIVE PAINT (P-1), RUBBER BASE (RB-1) AND CARPET (C-1), U.O.N. 8. ALL GYPSUM BOARD CEILINGS AND SOFFITS TO RECEIVE PAINT (P-1), U.N.O. 9. PAINT DECK ABOVE AND ALL EXPOSED MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION DUCTWORK AND PIPING IN OPEN CEILING AREAS. 10. ALL FINISHES TO BE INSTALLED PER THE MANUFACTURER’S INSTRUCTIONS. 11. ALL FINISH TRANSITIONS AT DOORS TO BE LOCATED CENTERED UNDER THE DOOR, U.O.N. 12. PROVIDE FLOORING TRANSITIONS AS FOLLOWS, U.O.N.: a. RUBBER REDUCING STRIP AT ALL TRANSITIONS BETWEEN CARPET AND RESILIENT FLOORING OR CONCRETE. b. STAINLESS STEEL TRIM BY SCHLUTER OR EQUAL, AT ALL TRANSITIONS BETWEEN TILE/STONE AND OTHER FINISHES. SCALE: 1/8" = 1'-0" 1FINISH PLAN 0 4' 8'16' 32' 1/8"=1'-0"N FINISHES INDICATES LINE OF FLOOR TRANSITION ITEM: MANUF.: COLOR/NO.: SIZE: INSTALLATION: STYLE: LVT 1 LVT - TYPICAL THROUGHOUT, U.O.N. SHAW CONTRACT INDUSTRIAL / 03520 12" X 12" MONOLITHIC CRETE ITEM: MANUF.: COLOR/NO.: FINISH: PL 1 PLASTIC LAMINATE FORMICA 7223C-58 / NEW WHITE MATTE ITEM: MANUF.: COLOR/NO.: FINISH: P 1 PAINT THROUGHOUT, U.O.N. SHERWIN WILLIAMS SW 6147 PANDA WHITE SEMI-GLOSS U.O.N., FLAT @ CEILINGS WALL FINISHES FLOOR FINISHES MISCELLANEOUS FINISHES ITEM: MANUF.: COLOR/NO.: FINISH: P 2 PAINT - ACCENT SHERWIN WILLIAMS SW 6473 SURF GREEN SEMI-GLOSS ITEM: MANUF.: COLOR/NO.: FINISH: P 3 PAINT - ACCENT SHERWIN WILLIAMS SW 6482 CAPE VERDE SEMI-GLOSS ITEM: MANUF.: COLOR/NO.: FINISH: P 4 PAINT - ACCENT SHERWIN WILLIAMS SW 6807 WONDEROUS BLUE SEMI-GLOSS ITEM: MANUF.: COLOR/NO.: FINISH: P 5 PAINT - ACCENT SHERWIN WILLIAMS SW 6809 LOBELIA SEMI-GLOSS ITEM: MANUF.: COLOR/NO.: FINISH: RB 1 RUBBER BASE THROUGHOUT JOHNSONITE #29 / MOON ROCK 4" COVE BASE, 6" COVE BASE AT HALLWAY ITEM: MANUF.: COLOR/NO.: SIZE: INSTALLATION: PW 1 RESTROOM PORCELAIN WAINSCOT ARIZONA TILE "TOUCH" SNOW 12" X 24" MONOLIGHTIC STACKED HORIZONTALLY, PROVIDE SCHLUTER EDGE TRIMS & TRANSITIONS ITEM: MANUF.: COLOR/NO.: SIZE: INSTALLATION: WT 1 WALL TILE - ACCENT DALTILE D617 ARCTIC WHITE 1" MAPEI, COLOR #27 SILVER, PROVIDE SCHLUTER EDGE TRIMS ITEM: MANUF.: COLOR/NO.: SIZE: INSTALLATION: STYLE: VCT 1 VCT - IT ROOM ARMSTRONG PEWTER / 5C908 18" X 18" MONOLITHIC PREMIUM EXCELSON ITEM: MANUF.: COLOR/NO.: SIZE: INSTALLATION: STYLE: PFT 1 PORCELAIN FLOOR TILE - RESTROOMS CROSSVILLE AV243 FOG 24" X 24" MONOLITHIC, PROVIDE SCHLUTER EDGE TRIMS & TRANSITIONS SHADES ITEM: MANUF.: COLOR/NO.: FINISH: PL 2 PLASTIC LAMINATE FORMICA 8844-WR / AGED ASH WOOD BRUSH (GRAIN TO RUN HORIZONTALLY, TYP.) ITEM: MANUF.: COLOR/NO.: FINISH: PL 3 PLASTIC LAMINATE FORMICA WINTER SKY 8792-58 MATTE ITEM: MANUF.: COLOR/NO.: FINISH: SSM 1 SOLID SURFACE CAESARSTONE CLASSICO - 6141 / OCEAN FOAM POLISHED ITEM: MANUF.: COLOR/NO.: FINISH: P 6 PAINT - ACCENT SHERWIN WILLIAMS SW 6230 RAINSTORM SEMI-GLOSS ITEM: MANUF.: COLOR/NO.: FINISH: P 7 PAINT - ACCENT SHERWIN WILLIAMS SW 7649 SILVERPLATE SEMI-GLOSS ITEM: MANUF.: COLOR/NO.: SIZE: INSTALLATION: STYLE: C 1 CARPET SHAW CONTRACT SLATE 13585 18" X 36" ASHLAR / DIRECT GLUE LINEWEIGHT TILE 5T114 DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 4 0 " M A X . MI N . 1 9 " 29 " C L R . 34 " M A X . M A X . 1 7 " 2 4 " 1 4 " ACCESSIBLE HEIGHT STANDARD HEIGHT TO H I G H E S T OP E R A B L E P A R T STANDARD HEIGHT GRAB BAR 1-1/2" Ø 8" MI N . 1 9 " CLR. 60" 1 7 " - 1 9 " 33 " - 3 6 " 17"-18" UNISEX RR 146UNISEX RR 145 UNISEX RR 100A TYP. 216 TYP. 216 145 100a 7'-10" @ SIDE WALL 4'-6" TYP. GRAB BAR @ R E A R W A L L 3' - 6 " T Y P . GR A B B A R TYP. 601 TYP. 606 1 ' - 6 " TYP. 608 605 603 146 TYP. 607 604 TYP. 613 TYP. 609 214 230 239 TYP. 602 I6.1 3A 3B 3D 3C TYP. 610 I6.1 2C2A TYP. 607 604 TYP. TYP. 616 TYP. 615 B6 1 8 " M I N . 1 8 " M I N . 2B 2D 2' - 6 " 2' - 6 " 4' - 0 " I6.1 2A SI M . 2DSIM. 2C SI M . 2BSIM. 619 UNISEX RR 145 UNISEX RR 100A F3 F3 F3 F3 F3 F3 F3 9'-0" EQ EQ . 5' - 0 " EQ . 4' - 0 " 4' - 0 " EQ . 5' - 0 " EQ EQ 9'-0" 9'-0" UNISEX RR 146 2' - 1 0 " P 1 PW 1 24 I8.3 TYP. 25 I8.3 TYP. 606 601 608 605 603 WT 1 TYP. 5' - 0 " 3' - 4 " EQ EQ PW 1 P 1 1 ' - 0 " SE E R C P TYP. TYP. 604 607 610609 CLEAR 1'-6" PW 1 1 ' - 0 " P 1 9" MAX 7" MIN. - 1 ' - 7 " 602 5' - 0 " PW 1 P 1 2' - 1 0 " 2' - 0 " 4' - 1 1 " 2'-4"7" 601 606 608 605 603 P 1 PW 1 WT 1 TYP. 617 5' - 0 " 3' - 4 " 604 607 610 1 ' - 0 " P 1 PW 1 619 5' - 0 " P 1 PW 1 2' - 1 0 " P 1 PW 1 1 ' - 0 " 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 2 2 P M K. BURGER CB / JG SDG22-6057-00 EN L A R G E D R E S T R O O M P L A N A N D E L E V A T I O N S I6.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 NOTE: ALL DIMENSIONS AND CALLOUTS TYPICAL FOR EACH ROOM, UNLESS NOTED OTHERWISE 214 SAW-CUT CONCRETE FLOOR THIS AREA AS REQUIRED FOR NEW PLUMBING. 216 PROVIDE NEW PLUMBING FIXTURES, ACCESSORIES, AND FINISHES IN EXISTING RESTROOM LOCATIONS PER CORTICA STANDARD SPECIFICATIONS. 230 PROVIDE NEW PLUMBING FIXTURES, ACCESSORIES, AND FINISHES PER CORTICA STANDARD SPECIFICATIONS. 239 WATER CLOSET TO HAVE MANUAL FLUSH. DO NOT PROVIDE AUTO-FLUSH. SCALE: 13/8" = 1'-0" ENLARGED RESTROOM PLANS • THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. RESTROOM MOUNTING HEIGHTS KEYNOTES: SEE SHEETS I0.1 -I0.2 FOR GENERAL NOTES SCALE: 23/8" = 1'-0" UNISEX RESTROOMS 145 & 146 ELEVATIONS N 0 1' 2' 4' 6' 3/8"=1'-0" 12' RESTROOM NOTES 1. PROVIDE DRAIN WITH TRAP PRIMER FOR EACH RESTROOM IF THERE ARE TWO OR MORE FIXTURES. SLOPE FLOOR TO DRAIN A MIN. 1/8" PER FOOT. 2. VERIFY BUILDING STANDARD FOR WALL-HUNG/DROP-IN COUNTER SINK WHERE APPLICABLE. 3. TOILET PAPER DISPENSERS SHALL NOT BE OF TYPE THAT CONTROLS DELIVERY, OR THAT DO NOT ALLOW CONTINUOUS PAPER FLOW. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAX. 4. OPERABLE PARTS OF ALL ACCESSORIES SHALL COMPLY WITH ALL APPLICABLE ACCESSIBILITY CODES AND STANDARDS. - 1 - - 2 - - 3A - - 3B - - 3C -- 3D - - 2A - - 2C - SCALE: 33/8" = 1'-0" UNISEX RESTROOM 100A ELEVATIONS DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 601 ACCESSIBLE HEIGHT WATER CLOSET. KOHLER HIGHCLIFF ULTRA (K-96057) WHITE, FLOOR MOUNTED. PROVIDE MANUAL FLUSH, NO AUTOMATIC FLUSH. REPLACE IN PLACE WHERE APPLIES. 602 SEAT COVER, NAPKIN DISPOSAL, TOILET TISSUE DISPENSER, BOBRICK CLASSIC SERIES SS RECESSED MODEL B-3574/MODEL B-35745 AS OCCURS. 603 SINK TOTO LT307(A) COMMERCIAL WALL-HUNG LAVATORY ONLY WITH SINGLE HOLE AND LEFT SIDE SOAP HOLE #01 COTTON, FAUCET SLOAN OPTIMA SYSTEMS EAF-100 ELECTRONIC HANDWASHING FAUCET, 6VDC PLUG IN ADAPTER, POLISHED CHROME. RE-USE EXISTING PLUMBING WHERE APPLIES. PROVIDE ADDITIONAL POWER AS REQUIRED. PROVIDE INSULATION AT ALL EXPOSED PIPING. 604 PAPER TOWEL DISPENSER, BOBRICK B-29744 SATIN FINISH SEMI-RECESSED AUTOMATIC, UNIVERSAL ROLL 6-VOLT DC POWER SUPPLY. 605 SOAP DISPENSER SLOAN SENSOR ACTIVITED ESD-600 POLISHED CHROME, PLUG-IN ADAPTOR POWERED. 606 GRAB BARS BOBRICK 36" & 48" LENGTH B-6806 1-1/2" DIAMETER. 607 TRASH WASTE RECEPTACLE, BOBRICK B-3644. 608 MIRROR BOBRICK B-293 1836, TILT MIRROR WITH STAINLESS STEEL FRAME SIZE 18" WIDE BY 36" HIGH. 609 COAT HOOK BOBRICK SOLID CAST ALUMINUM B-212, MATTE FINISH COAT HOOK WITH BUMPER. 610 BABY CHANGING STATION, KOALA KARE KB200-05 WHITE GRANITE, HORIZONTAL WALL MOUNTED. PROVIDE IN-WALL BACKING AS REQUIRED. 613 ALL REQUIRED ACCESSIBLE/FIXTURE CLEARANCES TO BE PROVIDED AT RESTROOM. 615 DENOTES LOCATION OF TACTILE RESTROOM SIGNAGE. SEE SHEET I0.3 FOR DETAILS. 616 DENOTES LOCATION OF GEOMETRIC RESTROOM SIGNAGE. SEE SHEET I0.3 FOR DETAILS. 617 PROVIDE SCHLUTER TRIM, ALL SIDES, WHERE NOTED ON PLAN. SPEC: SCHLUTER, QUADEC-E, TO COORDINATE WITH WAINSCOT TRIM. 619 EXISTING TAMPON DISPENSER TO REMAIN. RESTROOM REFLECTED CEILING PLAN FLOOR PLAN - 2B - - 2D - 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 CR WAITING 100 RECEPTION 101 CHECK OUT 102 207 209 102 I6.2 2A I6.22B 2C 2D 3'-9 " 13 5.0 0 ° R 7'-5 3/4" 2'-8" 234 218 237 135.0 0° 2' - 6 " I6.2 2E 202 235 CLEAR 3'-8" 3'-9 " 202 2'-6" 4' - 6 " 6' - 9 " 218 246 COPY/PRINT 103 7'- 0 " 103 WAITING 100 RECEPTION 101 CHECK OUT 102 F3 F3 F3 F3 F3 F4 F4 F4 F4 R 7'-5 3/4" 3' - 0 " 3' - 2 " 3' - 0 " 2' - 6 " 2' - 9 " 2' - 6 " 8'-2" 9'-10" 439 401 18 I8.2 2' - 6 " SE E R C P PL 1 WORKSURFACE COUNTER WITH CONCEALED IN-WALL SUPPORTS AND FINISH AS SCHEDULED 18 I8.3 OPEN 3' - 6 " 2' - 1 0 " 2' - 6 " SE E R C P SE E R C P SSM 1 PL 1 SSM 1 21 I8.3 RECEPTION 101 OPEN TO BEYOND (5) EQ. SPACES 14'-8" SE E R C P 3' - 0 " 2' - 2 " 2' - 1 0 " 4" 1 1 / 2 " PL 2 PL 1 PL 2 15 I8.3 TYP. 1 1/2" 3" COPY/PRINT 103 OPEN 2' - 6 " 3' - 0 " SSM 1 PL 1 3' - 6 " 1 ' - 0 " 2' - 1 0 " SSM 1 PL 2 PL 3 20 I8.3 1/4" X 1/4" PAINTED REVEAL (SHERWIN WILLIAMS, EL CARAMELO SW 9106) 410 8' - 2 " 2' - 0 " WAITING 100 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 2 6 P M K. BURGER CB / JG SDG22-6057-00 EN L A R G E D F L O O R P L A N A N D E L E V A T I O N S I6.2 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 202 PROVIDE BACKING SUPPORT BEHIND WALL-MOUNTED EQUIPMENT AND UPPER CABINET LOCATIONS. 207 NEW COPY/PRINTER MACHINE TO BE PROVIDED AND INSTALLED BY TENANT AT INDICATED LOCATION. PROVIDE REQUIRED POWER/DATA. 209 FLATSCREEN TV TO BE PROVIDED BY TENANT AND INSTALLED BY G.C. PROVIDE BACKING/ADDITIONAL SUPPORT AS REQUIRED. CONFIRM SIZE AND LOCATION WITH TENANT. 218 PROVIDE 30" WIDE X 30" HIGH PLASTIC LAMINATE WORK COUNTER WITH BUILT-IN WALL BRACKETS. COORDINATE GROMMET LOCATION WITH TENANT. 234 LOW WALL @ 42" A.F.F. WITH PLASTICE LAMINATE TOP CAP. SEE DETAIL L/A8.1 FOR MORE INFORMATION. 235 PROVIDE PLASTIC LAMINATE UPPER AND LOWER CABINETRY WITH 8" BAR PULLS, NO DRAWERS OR BACKSPLASH. PROVIDE PULL-OUT TRASH/RECYCLE. 237 PROVIDE CUSTOM RECEPTION DESK WITH SOLID SURFACE COUNTERTOP AND TRANSACTION TOP, PROVIDE PLASTIC LAMINATE VERTICAL FACES. WORKSURFACE TO BE 30" A.F.F. AND TRANSACTION TOP TO BE AT 42" A.F.F WITH 34" A.F.F. ACCESSIBLE COMPLIANT PORTION. 246 THIS DOOR TO BE PLAIN SLICED WALNUT VENEER WITH CLEAR COAT. SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION. • THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. KEYNOTES: SEE SHEETS I0.1 -I0.2FOR GENERAL NOTES SCALE: 13/8" = 1'-0" ENLARGED PLANS - RECEPTION 101 RESTROOM NOTES 1. PROVIDE DRAIN WITH TRAP PRIMER FOR EACH RESTROOM IF THERE ARE TWO OR MORE FIXTURES. SLOPE FLOOR TO DRAIN A MIN. 1/8" PER FOOT. 2. VERIFY BUILDING STANDARD FOR WALL-HUNG/DROP-IN COUNTER SINK WHERE APPLICABLE. 3. TOILET PAPER DISPENSERS SHALL NOT BE OF TYPE THAT CONTROLS DELIVERY, OR THAT DO NOT ALLOW CONTINUOUS PAPER FLOW. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAX. 4. OPERABLE PARTS OF ALL ACCESSORIES SHALL COMPLY WITH ALL APPLICABLE ACCESSIBILITY CODES AND STANDARDS. SEE SHEET I2.0 FOR FINISH, PLUMBING FIXTURES, RESTROOM ACCESSORIES, EQUIPMENT AND LIGHT FIXTURE SCHEDULES - 1A -- 1B - - 2D - - 2B - - 2E - - 2C - - 2A - N 0 1' 2' 4' 6' 3/8"=1'-0" 12' SCALE: 23/8" = 1'-0" MILLWORK ELEVATIONS DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 401 THIS ROOM/AREA IS OPEN TO STRUCTURE ABOVE. PROVIDE GALVANIZED RIGID DUCTS, ROUND DIFFUSERS AND RIGID CONDUITS. ALL MECHANICAL, ELECTRICAL, PLUMBING, TELECOMMUNICATIONS AND AUDIO VISUAL COMPONENTS VISIBLE AT OPEN CEILING AREAS ARE TO BE INSTALLED NEATLY. PAINT EXPOSED STRUCTURE AND CEILING ELEMENTS P-1 FLAT FINISH. 410 NEW METAL STUDS AND GYPSUM BOARD SOFFIT TO FOLLOW RECEPTION DESK CURVE. SOFFIT TO RECEIVE PAINT (P-1) FLAT FINISH. SOFFIT TO BE AT +/- 8'-2" A.F.F. TO ALIGN WITH DOOR FRAME. 439 DASHED LINE INDICATES LOCATION OF GYP. BOARD CEILING EXTENSION, CONSTRUCTED UP TO UNDERSIDE OF STRUCTURE. REFLECTED CEILING PLAN FLOOR PLAN 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 ± 8 ' - 0 " TO U N D E R S I D E O F S T R U C T U R E 618 2' - 1 0 " 2' - 2 " 3' - 0 " 4" 1 1 / 2 " PL 2 PL 1 PL 2 P 1 EQ. SPACES 7'-4 1/2" 1 1/2" 13 I8.3 4" STAFF BREAK 144 OPEN TO BEYOND 3' - 0 " 2' - 2 " 1 1 / 2 " 4" 1 1/2" EQ. SPACES ± 10'-10 1/2" 1 1/2" 1 1/2" ± 3'-0" ADA 3'-0" RECY. 1'-6" TRSH. 1'-6" 2'-0" 1 1/2" VERIFY 3'-10" 1 1/2" 2' - 0 " VE R I F Y 6' - 0 " PL 2 PL 1 PL 2 10 I8.3 9 I8.3 5 I8.3 TO U N D E R S I D E O F S T R U C T U R E 16 I8.3 TYP. MA X 4' - 0 " 2' - 1 0 " 2' - 2 " 3' - 0 " SE E R C P 1 1/2" 4" PL 2 PL 1 TYP. PL 2 RB 1 P 1 CONSULT 147 4'-6" 1'-6" 1'-7 1/2" 3'-0"1 1/2" 2' - 6 " SE E R C P PL 1 19 I8.3 TYP. OFFICE 105 RB 1 (3) EQ. 9'-7" 2' - 1 0 " 2' - 2 " 3' - 0 " SE E R C P PL 2 PL 1 PL 2 OFFICE 157 15 I8.3 TYP. 1 1/2" 1 1/2" ± 4 ' - 8 " 3' - 0 " PROVIDE FROSTED FILM 3M FASARA, SH2MAML MILANO OPEN OFFICE 150 TO U N D E R S I D E O F S T R U C T U R E PROVIDE FROSTED FILM 3M FASARA, SH2MAML MILANO 5' - 0 " 1' - 0 " CONFERENCE 106 T (3) EQ. SPACES 9'-1 1/2" 1 1/2" 1 1/2" SE E R C P 2' - 1 0 " 2' - 2 " 3' - 0 " PL 2 PL 1 PL 2 OFFICE 114 2' - 1 0 " 2' - 2 " 3' - 0 " 4" PL 2 PL 1 TYP. PL 2 TRAINING 116 8 I8.3 EQ. 4'-6" 3'-0" 1'-7 1/2" 1'-6"1 1/2" 23 I8.3 1 1/2" P 4 P 5 RB 4 OPEN OFFICE 150 EXIT ROUTE 4' - 0 " 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 3/ 1 6 / 2 0 2 3 4 : 3 0 : 3 5 P M K. BURGER CB / JG SDG22-6057-00 MI L L W O R K & G L A Z I N G E L E V A T I O N S I6.3 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & S U I T E 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 1. ALL MILLWORK SHALL CONFORM TO THE CURRENT WOODWORK INSTITUTE STANDARDS PREMIUM GRADE. 2. SHOP DRAWINGS FOR ALL CABINETRY AND MILLWORK ARE REQUIRED TO BE SUBMITTED TO ARCHITECT AND OWNER FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. 3. SEE FINISH SCHEDULE FOR FINISH SPECIFICATIONS. 4. DOOR PULLS SHALL BE: 7.4" E.B. BRADLEY, EPCO BAR PULL, #E128-01-SS OR EQUAL. 5. COUNTERTOPS SHALL HAVE BACK-SPLASHES ONLY WHERE SHOWN ON ELEVATION. 6. CABINET INTERIORS SHALL BE WHITE MELAMINE, INCLUDING EDGES. 7. INTERIOR SHELVING SHALL BE COVERED IN WHITE MELAMINE. 8. DOORS SHALL BE OF FLUSH OVERLAY CONSTRUCTION. 9. DOORS EDGES SHALL BE EDGE BANDED TO MATCH THE FRONTS. 10. INTERIOR OF DOOR SHALL BE FACED WITH SAME MATERIAL AS THE FRONTS. 11. ALL DRAWERS TO HAVE ACCURRIDE (OR APPROVED EQUAL) - FULL EXTENSION GLIDES. 12. EACH CABINET DOOR TO BE NO LESS THAN 12" WIDE AND NO GREATER THAN 18" WIDE U.O.N. 13. (*) VERIFY ALL EQUIPMENT CLEARANCES. SEE I0.3 - I0.3a ACCESSIBILITY DETAILS FOR ADDITIONAL CLEARANCE INFORMATION. 14. PROVIDE SOFT CLOSE ACCURIDE OR EQUAL HARDWARE ON ALL CABINETS AND DRAWERS. MILLWORK/CABINETRY NOTES 1. SEE SHEETS I0.1 - I0.2 FOR GENERAL NOTES. 2. SEE PLUMBING DRAWINGS FOR PLUMBING FIXTURE INSTALLATIONS AND SEE I0.3a FOR MOUNTING AND CLEARANCES. 3. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT ARISE. GENERAL NOTES - 1C - - 1B - - 1A - SCALE: 3/8" = 1'-0" 3MILLWORK ELEVATION SCALE: 3/8" = 1'-0" 2MILLWORK ELEVATION SCALE: 3/8" = 1'-0" 4MILLWORK ELEVATION SCALE: 3/8" = 1'-0" 7GLAZING ELEVATION SCALE: 3/8" = 1'-0" 8GLAZING ELEVATION SCALE: 13/8" = 1'-0" MILLWORK ELEVATIONS SCALE: 3/8" = 1'-0" 5MILLWORK ELEVATION SCALE: 3/8" = 1'-0" 6MILLWORK ELEVATION DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 1 20 2 3 - 0 3 - 1 6 IS S U E F O R P L AN C H E C K C O R R E C T I O N S 618 TENANT PROVIDED CEILING MOUNTED TV. COORDINATE WITH TENANT AND AV VENDOR FOR FINAL INSTALLATION HEIGHT AND LOCATION. KEYNOTES: FLOOR PLAN SCALE: 3/8" = 1'-0" 1 ELEVATION 1 1 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 SOLID FLUSH WIDTH F1 I8.3 1 HE I G H T FS1 HE I G H T SOLID FLUSH WITH SIDELIGHT WIDTH I8.3 2 I8.3 3 I8.3 4 U.O.N. 2'-0" T TEMPERED GLASS N1 NARROW LIGHT WIDTH HE I G H T MA X . 3' - 7 " 8"x36" VISION PANEL (CLEAR TEMPERED GLASS) TO BE ADDED INTO EXISTING DOORS T TEMPERED GLASS T 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 3 3 P M K. BURGER CB / JG SDG22-6057-00 DO O R S C H E D U L E A N D D E T A I L S I7.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 DOOR HARDWARE HARDWARE SPECIFICATIONS OPERATING HARDWARE DOOR TYPES GENERAL NOTES NOTE: AT EXISTING DOORS WHICH REMAIN, HARDWARE INDICATED IN THIS SCHEDULE IS NEW AND TO BE ADDED TO THE EXISTING ASSEMBLY. (X) LETTER IN PARENTHESIS INDICATES EXISTING COMPONENT. WIDTH HEIGHT DOOR SCHEDULE DOUBLE DOORS KI C K P L A T E S DOOR KEYNOTESCO A T H O O K DO O R S T O P W: W A L L F: F L O O R ROOM NAME. DOOR NO. PER HARDWARE SPECIFICATIONS SECTION BELOW, U.O.N. DO O R BO T T O M SE A L S A: A C O U S T I C S: S M O K E HO L D OP E N S AS T R A G A L CO O R D . CL O S E R S: S U R F A C E X: C O N C E A L E D CA R D RE A D E R PA N I C DE V I C E DOOR COMPONENTS OP E R A T I N G HA R D W A R E HA R D W A R E GR O U P FI R E R A T I N G (M I N U T E S ) FR A M E SP E C I F I C A T I O N DO O R SP E C I F I C A T I O N DOOR SIZE DO O R T Y P E EL E V A T I O N W: W E A T H E R O: O V E R H E A D 100 WAITING SF2 6'-0"9'-8"EXIST. EXIST.B2 2i YES S 2, 3 100a UNISEX RR F1 3'-0"8'-0"D1 FR1 B1 1d F YES 102 CHECK OUT FS1 3'-0"8'-0"D2 FR1 B2 1e S F 1, 5 103 COPY/PRINT F1 3'-0"8'-0"EXIST. EXIST.B2 2i YES S F 3 104 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 105 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 106 CONFERENCE FS1 3'-0"8'-0"EXIST. FR1 B1 1e F EXISTING DOOR TO REMAIN, PROTECT. PROVIDE NEW FRAME FOR INTEGRAL SIDELITE PER PLAN. 107 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 108 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 109 STORAGE F1 3'-0"8'-0"EXIST. EXIST.B2 1a S F 3 110 IT/SERVER F1 3'-0"8'-0"EXIST. EXIST.B2 1a S F 3, 4 111 STORAGE F1 3'-0"8'-0"D1 FR1 B1 1a F 6 112 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 113 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 114 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 115 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 116 TRAINING FS1 3'-0"8'-0"D1 FR1 B1 1e F 6 117 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 118 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 119 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 120 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 121 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 122 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 123 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 124 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 125 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 126 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 127 OFFICE F1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 128 OFFICE N1 3'-0"8'-0"EXIST. FR1 B1 1e F EXISTING DOOR TO REMAIN, PROTECT. PROVIDE NEW FRAME AS REQUIRED TO ACCOMMODATE NEW LAYOUT. 129 OFFICE N1 3'-0"8'-0"EXIST. FR1 B1 1e F EXISTING DOOR TO REMAIN, PROTECT. PROVIDE NEW FRAME AS REQUIRED TO ACCOMMODATE NEW LAYOUT. 130 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 131 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 132 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 133 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 134 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 135 OFFICE N1 3'-0"8'-0"D1 FR1 B1 1e F 6 136 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 137 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 138 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 139 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 140 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 141 OFFICE FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 142 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 143 PHONE N1 3'-0"8'-0"EXIST. EXIST.B1 1d F 3 144 STAFF BREAK N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 145 UNISEX RR F1 3'-0"8'-0"EXIST. EXIST.B1 1d F YES 3 146 UNISEX RR F1 3'-0"8'-0"EXIST. EXIST.B1 1d F YES 3 147 CONSULT FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 148 CONSULT FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 149 CONSULT FS1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 150a OPEN OFFICE N1 3'-0"8'-0"D1 FR1 B2 1e S F 6 150b OPEN OFFICE N1 3'-0"8'-0"D1 FR1 B2 1e S F 6 150c STORAGE F1 3'-0"8'-0"D1 FR1 B2 1a S F 4 150d STORAGE F1 3'-0"8'-0"EXIST. EXIST.B2 1a S F 3, 4 151 CONSULT N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 152 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 153 TELEHEALTH N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 154 TELEHEALTH N1 3'-0"8'-0"D1 FR1 B1 1e F 6 155 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 156 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 157 OFFICE N1 3'-0"8'-0"EXIST. EXIST.B1 1e F 3 158 WAITING FS1 3'-0"8'-0"D2 FR1 B2 1e S F 1, 5 161 HALLWAY F1 3'-0"8'-0"EXIST. EXIST.B2 2i S F 3 163 HALLWAY F1 3'-0"8'-0"EXIST. EXIST.B2 2i YES S F 3 164 HALLWAY F1 3'-0"8'-0"D1 FR1 B2 2i YES S F COORDINATE WITH ADJACENT TENANT FOR DOOR REQUIREMENTS. DOOR AND FRAME SPECIFICATIONS WESTERN INTEGRATED (MATCH EXISTING) CLEAR ANODIZED ALUMINUM (MATCH EXISTING) MARSHFIELD (MATCH EXISTING) SIGNATURE SERIES (MATCH EXISTING) SOLID CORE 5-PLY STAINGRADE WOOD VENEER, MATCH EXISTING FACE MATERIAL: WHITE MAPLE, QUARTERED, FINISH: THICKNESS: MANUFACTURER: FR1 FRAME: ALUMINUM MANUFACTURER: STYLE/SERIES: D1 DOOR: WOOD MATERIAL: CONSTRUCTION: SLIP MATCHED (MATCH EXISTING) 1 3/4" A. SEE SHEET I0.2 FOR GENERAL DOOR NOTES. B. ALL HARDWARE SHALL MEET ALL APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES. C. REFER TO THE FLOOR PLANS AND SPECIFICATIONS (IF PROVIDED) FOR ADDITIONAL DOOR INFORMATION. D. ALL DOOR FRAMES TO BE FACTORY FINISHED, U.O.N. E. RATED DOORS SHALL HAVE AUTOMATIC CLOSERS AND COMPLY WITH REQUIREMENTS OF ALL GOVERNING CODES AND STANDARDS. ** EXISTING TENANT ENTRY DOORS TO BE IN FULL COMPLIANCE WITH CITY OF SANTA ANA SECURITY STANDARDS. SEE SECURITY NOTES ON I0.2 FOR MORE INFORMATION. BUTT HINGES: 1. IVES 3 KNUCKLE 3CB1 SERIES (OR 5 KNUCKLE 5BB1 SERIES) OR APPROVED EQUAL. 2. SIZE: a. 3-1/2" X 3-1/2" X 0.123 GA FOR 1-3/8" DOORS. b. 4-1/2" X 4-1/2" X 0.134 GA FOR 1-3/4" DOORS TO 36" WIDE. c. 4-1/2" X 4-1/2" X 0.180 GA FOR 1-3/4" FOR DOORS GREATER THAN 36" TO 42" WIDE. d. 5" X 4-1/2" X 0.190 GA FOR 1 3/4" FOR DOORS GREATER THAN 42" TO 48" WIDE. e. MANUFACTURER'S GUIDELINES FOR ALL OTHER DOOR THICKNESSES. 3. QUANTITY: 1-1/2 PAIRS FOR DOORS 60" TO 90" IN HEIGHT AND AN ADDITIONAL 1/2 PAIR FOR EVERY 30" OR FRACTION THEREOF. 4. MATERIAL: a. ALL EXTERIOR OUTSWING DOOR BUTTS SHALL BE MADE OF NON- FERROUS MATERIAL AND SHALL HAVE STAINLESS STEEL HINGE PINS. b. ALL EXTERIOR OUTSWING DOORS SHALL HAVE NON-REMOVEABLE PINS. c. ALL FIRE RATED DOORS OR DOORS WITH CLOSING DEVICES SHALL HAVE BALL BEARING STEEL HINGES. PIVOTS: 1. IVES 7000 SERIES. 2. HIGH STRENGTH FORCED BRONZE OR STAINLESS STEEL TILT-ON PRECISION BEARING AND BEARING PIN. a. BOTTOM AND INTERMEDIATE PIVOTS: ADJUSTABILITY OF MINUS 1/16", PLUS 1/8". CLOSING DEVICES: 1. CONCEALED - FLOOR: DORMA BTS 80 SERIES. a. HYDRAULICALLY CONTROLLED, CEMENT CASE, MAXIMUM DEGREE DEAD STOP PERMITTED BY TRIM OR ADJACENT STRUCTURE. PROVIDE SPECIAL PINS, FLOOR PANS, AND LONGER SPINDLES TO ACCOMMODATE FLOOR AND JAMB CONDITIONS. 2. CONCEALED - OVERHEAD: LCN 2030 SERIES OR APPROVED EQUAL. a. CONCEALED IN TRACK BUMPERS WHERE SCHEDULED. 3. SURFACE - LCN 1461 SERIES OR APPROVED EQUAL. a. PROVIDE "DS" DESIGNER SERIES COVERS AT ALL DOORS VISIBLE BY THE PUBLIC (STANDARD COVERS AT MAINTENANCE ROOMS). 4. MAX. EFFORT TO OPERATE DOORS: a. EXTERIOR DOORS - 5 LBS. b. INTERIOR DOORS - 5 LBS. c. FIRE RATED DOORS - 15 LBS. 5. A CLOSING DEVICE MUST BE USED ON ALL FIRE-RATED DOORS. STOPS: 1. IVES WS40S7/FS436 SERIES DOOR STOPS: a. WS406/407 CVX/CCV WALL STOP OR APPROVED EQUAL, TYPICAL U.O.N. b. FS436/R435 DOME FLOOR STOP (SIZE BASE TO FIT) OR APPROVED EQUAL - WHERE WALL STOP WILL NOT WORK. c. WHERE WALL OR FLOOR STOPS WILL NOT WORK PROVIDE AN OVERHEAD STOP OR SPRING "CRUSH" ARM ON THE CLOSER. MAGNETIC HOLDERS: 1. LCN SEM7800 (24 VDC/VAC) MAGNETIC HOLDER OR APPROVED EQUAL AT FIRE-RATED AUTOMATIC RELEASE DOORS. a. PROVIDE EXTENDED ARMATURES AS REQUIRED TO SUIT CONDITIONS. DOOR COORDINATORS (COORDINATORS TO MATCH DOOR FRAME): 1. IVES COR SERIES OR APPROVED EQUAL, SIZED TO FIT FROM STOP TO STOP. a. PROVIDE FULL LENGTH BRACKET FOR MOUNTING TO ALUMINUM FRAME. 2. IF JAMB STOP DOES NOT PERMIT USE OF IVES COR SERIES, SUBSTITUTE IVES CORG SERIES, GRAVITY COORDINATORS. KICK PLATES: 1. IVES 8400/8402 SERIES OR APPROVED EQUAL. 2. PROVIDE 8400 SERIES AT NON-RATED DOORS AND 8402 SERIES AT FIRE RATED DOORS. 3. SIZE AS FOLLOWS: a. 10"x 2" LESS THAN DOOR WIDTH - SINGLE DOOR b. 10"x 1" LESS THAN DOOR WIDTH - PAIR OF DOORS. WEATHER STRIPPING: 1. ZERO INTERNATIONAL (ZER) OR APPROVED EQUAL: a. THRESHOLDS - ZER 545 OR AS SHOWN ON SILL DETAILS AND AS REQUIRED TO SUIT CONDITIONS AT EXTERIOR DOORS. b. HEAD RAIN DRIPS - ZER 142 OR AS SHOWN ON HEAD DETAILS AND AS REQUIRED TO SUIT CONDITIONS AT EXTERIOR DOORS. (OMIT AT DOOR SHELTERED WITH OVERHANGS). c. BOTTOM RAIN DRIPS - ZER 11 OR AS SHOWN ON SILL DETAILS AND AS REQUIRED TO SUIT CONDITIONS. (AT IN-SWING DOORS). d. DOOR BOTTOMS/SHOES - ZER 8198 OR AS SHOWN ON SILL DETAILS AND REQUIRED TO SUIT CONDITIONS AT OUT-SWINGING EXTERIOR DOORS. e. DOOR BOTTOMS/SHOES - ZER 381 OR AS SHOWN ON SILL DETAILS AND AS REQUIRED TO SUIT CONDITIONS AT IN-SWINGING EXTERIOR DOORS. f. HEAD AND JAMB SEALS - ZER 8042 (OR AS REQUIRED TO MEET FIRE LABEL RATING) AT EXTERIOR DOORS AND FIRE RATED DOORS. (OMIT AT ALUMINUM FRAMES). g. ASTRAGALS - 383 AT NON-RATED WOOD DOORS AND 383FS AT FIRE RATED WOOD DOORS. (SEE LATCHGUARDS FOR EXTERIOR AND HOLLOW METAL DOORS) LATCHGUARDS: 1. IVES LG SERIES OR APPROVED EQUAL FOR SINGLE OUTSWING EXTERIOR DOORS. 2. ZER 44SP SERIES ASTRAGAL OR APPROVED EQUAL FOR PAIRS OF EXTERIOR HOLLOW METAL DOORS WITHOUT PANIC HARDWARE. KEYING: 1. ON NEW CONSTRUCTION: PROVIDE SCHLAGE LARGE FORMAT INTERCHANGEABLE CORE CYLINDERS WITH CONSTRUCTION CORES AND A PERMANENT CORE. 2. ON EXISTING WORK: MATCH BUILDING STANDARD OR AS DIRECTED BY OWNER AND ARCHITECT. BOLTS: 1. MANUAL FLUSH BOLTS: a. IVES FB458 OR APPROVED EQUAL b. LENGTH TO SET AS FOLLOWS: A. BOTTOM BOLTS 12" B. TOP BOLT 12" FOR DOORS TO 84" IN HEIGHT C. TOP BOLT 12" PLUS AS 1" FOR EVERY ADDITIONAL INCH OF DOOR HEIGHT OVER 84" c. DO NOT USE ANY ROOMS NORMALLY OCCUPIED BY PEOPLE 2. AUTOMATIC FLUSH BOLTS: a. IVES FB30 OR APPROVED EQUAL FOR HOLLOW METAL DOORS b. IVES FB40 OR APPROVED EQUAL FOR WOOD DOORS c. AUTOMATIC FLUSH BOLTS MUST BE USED AT ALL PAIRS OR FIRE RATED DOORS. 1. CYLINDRICAL LOCKS FALCON "T" SERIES LATCHING HARDWARE (FOR USE ON INTERIOR DOORS ONLY) LEVER DESIGN: "QUANTUM" FINISH: #626 SATIN CHROMIUM PLATED (OR APPROVED EQUAL) a. STOREROOM LOCK b. OFFICE LOCK c. ENTRANCE LOCK d. BATH PRIVACY LOCK e. PASSAGE LATCH f. DOUBLE CYLINDER VESTIBULE LOCK g. CLASSROOM LOCK h. DOUBLE CYLINDER CLASSROOM LOCK i. ELECTRIC LOCKSET (FAIL SAFE OR FAIL SECURE AS REQUIRED) 2. MORTISE LOCKS FALCON "T" SERIES LATCHING HARDWARE (FOR USE ON EXTERIOR AND INTERIOR DOORS) LEVER DESIGN: "QUANTUM" FINISH: #626 SATIN CHROMIUM PLATED (OR APPROVED EQUAL) a. STOREROOM LOCK b. OFFICE LOCK c. ENTRANCE LOCK d. BATH PRIVACY LOCK e. PASSAGE LATCH f. DOUBLE CYLINDER VESTIBULE LOCK g. CLASSROOM LOCK h. DOUBLE CYLINDER CLASSROOM LOCK i. ELECTRIC LOCKSET (FAIL SAFE OR FAIL SECURE AS REQUIRED) REMARK KEY NOTES 1. DOOR TO RECEIVE WALNUT VENEER FINISH. 2. EXISTING STOREFRONT ENTRY DOOR. 3. EXISTING DOOR TO REMAIN. MODIFY AS REQUIRED PER SCHEDULE. 4. PROVIDE KEYPAD LOCK. TENANT TO PROVIDE SPECIFICATION. 5. PROVIDE BLANK STRIKE PLATE. 6. RELOCATED DOOR. MODIFY AS REQUIRED PER SCHEDULE. HARDWARE GROUPS MARSHFIELD (MATCH EXISTING) SIGNATURE SERIES (MATCH EXISTING) SOLID CORE 5-PLY PLAIN SLICED, WALNUT VENEER, CLEAR COAT FACE MATERIAL: WHITE MAPLE, QUARTERED, FINISH: THICKNESS: MANUFACTURER: STYLE/SERIES: D2 DOOR: WOOD CONSTRUCTION: SLIP MATCHED 1 3/4" * = QUANTITY, TYPE AND SIZE DETERMINED BY DOOR TYPE AND SIZE, REFER TO HARDWARE SPECIFICATIONS B1 - STANDARD DOOR * EA HINGE 1 EA OPEARATING HARDWARE 1 EA STOP B2 - STANDARD DOOR W/ CLOSER * EA HINGE 1 EA OPERATING HARDWARE 1 EA SURFACE CLOSER 1 EA STOP DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 5/8" MOISTURE RESISTANT BOARD OVER METAL STUDS, SEE METAL STUD TABLE FOR SPACING BRACE TO STRUCTURE, ALTERNATE SIDES. USE METAL STUDS @ 4'-0" O.C , MATCH WALL STUD SIZE & GAUGE (3-5/8" 20 GA. MIN) BEND WEB & FASTEN TO TOP TRACK . MAX. LENGTH OF BRACE 25'-0" 45 ° WALL TAG MODIFIERS: B3 = 3-5/8" METAL STUDS B4 = 4" METAL STUDS B6 = 6" METAL STUDS B8 = 8" METAL STUDS ACOUSTICAL INSULATION FLOOR LINE ACOUSTICAL SEALANT LARR # 25889 TOP TRACK SECURED TO WALL BRACE W/ (2) #8 SHEET METAL SCREWS LARR # 25889 5/8" GYPSUM BOARD OVER METAL CEILING JOISTS, SEE METAL JOIST TABLE FOR SPACING PLUMBING WALL 1 / 2 " BOTTOM TRACK FASTENED TO FLOOR @ 16" O.C. MAX. WALL BASE WHERE OCCURS, SEE FINISH PLANS INSULATION WHERE OCCURS, SEE FLOOR PLANS 5/8" GYPSUM BOARD EACH SIDE OVER METAL STUDS, SEE METAL STUD TABLE FOR SPACING BOTTOM TRACK FASTENED TO FLOOR @ 16" O.C. MAX. FLOOR LINE ACOUSTICAL SEALANT CEILING TYPE AND HEIGHT PER CEILING PLAN TOP TRACK SECURED TO WALL BRACE w/ (2) #8 SHEET METAL SCREWS BRACE TO STRUCTURE, ALTERNATE SIDES. USE METAL STUDS @ 4'-0" O.C , MATCH WALL STUD SIZE & GAUGE (3-5/8" 20 GA. MIN) BEND WEB & FASTEN TO TOP TRACK . MAX. LENGTH OF BRACE 25'-0" 45° 1 / 2 " WALL TAG MODIFIERS: A2 = 2-1/2" METAL STUDS A3 = 3-5/8" METAL STUDS A4 = 4" METAL STUDS A6 = 6" METAL STUDS A8 = 8" METAL STUDS LARR # 25889 WALL TO 6" ABOVE CEILING DECK LINE WALL TYPE PATTERN WALL BASE WHERE OCCURS, SEE FINISH PLANS 6" WALL TAG MODIFIERS: F2 = 2-1/2" METAL STUDS F3 = 3-5/8" METAL STUDS F4 = 4" METAL STUDS F6 = 6" METAL STUDS F8 = 8" METAL STUDS INSULATION WHERE OCCURS, SEE FLOOR PLANS 5/8" GYPSUM BOARD EACH SIDE OVER METAL STUDS, SEE METAL STUD TABLE FOR SPACING FLOOR LINE ACOUSTICAL SEALANT LARR # 25889 DECK LINE FULL HEIGHT NON-RATED WALL I8.1 8 I8.1 13 BOTTOM TRACK FASTENED TO FLOOR @ 16" O.C. MAX. SLIPTRACK FASTENED TO DECK @ 16" O.C. MAX. SLIPTRACK ISOMETRIC WALL TYPE PATTERN WALL BASE WHERE OCCURS, SEE FINISH PLANS 2" x 2" x 14 GA. STEEL TUBE WELDED TO 3-1/2"x8"x3/8" THICK STEEL PLATE, 5'-0" O.C. - PLAN VIEW - STEEL PLATE BOLTED TO SLAB WITH (2) 5/8" DIA. HILTI KB-TZ. IMBED 3-1/8" ICC-ESR-1917 3 1 / 2 " EQ E Q 8" CORNER BEAD 1" EQ EQ 3-5/8" x 25 GA. METAL STUDS @ 16" O.C. 5/8" GYPSUM BOARD EACH SIDE BOTTOM TRACK WITH POWER- DRIVEN FASTENERS @ 16" O.C. MAX. ICC-ESR-1752 LOW WALL N. T . S . 6" CORNER BEAD 42 " H I G H - S E E F L O O R P L A N EXISTING FLOOR LINE WALL BASE WHERE OCCURS, SEE FINISH PLANS 1 / 2 " 1 1 / 2 " 1/2" SPACER, PAINT TO MATCH WALL PL-2 PLASTIC LAMINATE TOP CAP. SEE FINISH PLAN. 1-1/2" x 4" 12 GA. ANGLE CLIP, MATCH BRACE/STRUT WIDTH WITH (2) #10 SCREWS TYP. METAL DIAGONAL BRACE AS SHOWN ON WALL TYPE WOOD ROOF/FLOOR DECK PURLINS OR 2x BLOCKING ATTACHED TO DECK SUPPORTS WITH HANGERS WOOD SCREWS ICC-ESR-2236 BOTTOM TRACK WITH POWER- DRIVEN FASTENERS @ 16" O.C. MAX. ICC-ESR-1752 LARR #22668 CONCRETE FLOOR #10 SCREWS (TYP.) ACCOUSTICAL SEALANT FULL HEIGHT NON-RATED WALL 1 / 2 " WALL BASE WHERE OCCURS, SEE FINISH PLANS PURLINS OR 2x BLOCKING ATTACHED TO DECK SUPPORTS WITH HANGERS 1 / 2 " M I N . WOOD FLOOR/ ROOF DECK CEMCO SLOTTED TRACK (CST) ICC-ESR-2012 WITH WOOD SCREWS @ 16" O.C. MAX. ICC-ESR-2236 WALL TYPE NOTES: 1. INTERIOR GYP. BD. WALLS SHALL CONFORM TO ICC-ESR-1338 2. SEE LIMITING WALL HEIGHT TABLE FOR METAL STUD GAUGE AND SPACING BASED ON WALL HEIGHTS AND STUD SIZES AS NOTED ON EACH WALL TYPE. 3. MAX. STUD SPACING SHALL BE 24". 4. MINIMUM FASTENER SIZE SHALL BE #6 - 1-1/4" SCREWS. 5. MAXIMUM FASTENER SPACING SHALL BE 12" FIELD AND 8" AT EDGES. 6. ALL WALL STUDS TO BE 3-5/8", U.O.N. 7. ALL RESTROOM WALL STUDS TO BE 6" AND FULLY INSULATED, U.O.N. DESIGN BUILD METAL STUD: 1. STEEL STUDS AND RUNNERS: MINIMUM BASE-METAL THICKNESS: a. 25 GAGE UNLESS INDICATED OTHERWISE ON DRAWINGS OR BELOW: 1) INTERIOR METAL STUD/GYPSUM BOARD ASSEMBLIES, TYPICAL LOCATIONS: WITHSTAND LATERAL LOADING (AIR PRESSURE) OF 5 PSF WITH DEFLECTION LIMIT NOT MORE THAN L/240 OF PARTITION HEIGHT. 2) INTERIOR METAL STUD/GYPSUM BOARD ASSEMBLIES AT LOCATIONS WITH CERAMIC TILE OR OTHER HARD SURFACE FINISHES: WITHSTAND TYPICAL LATERAL LOADING (AIR PRESSURE) WITH DEFLECTION LIMIT NOT MORETHAN L/360 OF PARTITION HEIGHT, MINIMUM 20 GAGE STUDS AT 16" ON CENTER 3) WHERE WALL MOUNTED EQUIPMENT, WOODWORK, AND CASEWORK ITEMS ARE INDICATED OR ELSEWHERE AS SHOWN ON DRAWINGS, PROVIDE MINIMUM 16 GAGE STUDS. 4) AT PARTITIONS SCHEDULED TO RECEIVE TILE BACKING PANELS OR CERAMIC TILE FINISH, PROVIDE MINIMUM 22 GAGE STUDS. 5) AT JAMBS OF OPENINGS PROVIDE TWO MINIMUM 20 GAGE STUDS. 6) CEILINGS: AT CEILINGS USING MOLD-MILDEW RESISTANT GYPSUM, FRAMING TO BE 16 INCHES O.C. FOR 5/8" GYPSUM. 7) REFER TO DIVISION 5 FOR COLD FORMED STUD FRAMING WHICH IS EXPOSED TO WIND LOADS AND FOR STUDS CARRYING HEAVY VERTICAL LOADS (STONE TILE THICKER THAN 3/4 INCH, ETC) b. WHERE PARTITION HEIGHTS EXCEED STUD MANUFACTURER'S RECOMMENDED SPANS, PROVIDE STRUCTURAL CALCULATIONS. 10'-6"250S125-18 12" (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 9'-7"16" 24"8'-3" INTERIOR NON-STRUCTURAL NON-COMPOSITE: (S) STUD MEMBER SPACING (IN.) O.C. 5 PSF L/240 250S125-18 250S125-18 12" 16" 24" 250S125-33 13'-2" 12'-0" 10'-6" 250S125-33 250S125-33 11'-5" 13'-0" 14'-4" 24" 16" 12"250S125-43 250S125-43 250S125-43 362S125-18 9'-11" 12'-2" 14'-0"12" 16" 24" 362S125-18 362S125-18 362S125-33 12" 16" 24" 17'-7" 16'-0" 14'-0" 362S125-33 362S125-33 362S125-43 15'-3" 17'-5" 19'-2"12" 16" 24" 362S125-43 362S125-43 362S125-54 (50 KSI)12" 16" 24"16'-3" 18'-7" 20'-6" 362S125-54 (50 KSI) 362S125-54 (50 KSI) 12" 16" 24"16'-5" 18'-10" 20'-9"400S125-43 362S125-68 (50 KSI)12" 16" 24"17'-5" 19'-11" 21'-11" 362S125-68 (50 KSI) 362S125-68 (50 KSI) 400S125-18 12" 16" 24"10'-5" 12'-10" 14'-9" 400S125-18 400S125-18 400S125-33 12" 16" 24"15'-1" 17'-3" 19'-0" 400S125-33 400S125-33 400S125-43 400S125-43 12" 16" 24"17'-7" 20'-2" 22'-2"400S125-54 (50 KSI) 400S125-54 (50 KSI) 400S125-54 (50 KSI) 12" 16" 24"18'-10" 21'-6" 23'-8"400S125-68 (50 KSI) 400S125-68 (50 KSI) 400S125-68 (50 KSI) 12" 16" 24"17'-7" 21'-6" 24'-4"600S125-27 600S125-27 600S125-27 12" 16" 24"20'-6" 23'-9" 26'-2"600S125-33 600S125-33 600S125-33 12" 16" 24"22'-10" 26'-1" 28'-9"600S125-43 600S125-43 600S125-43 12" 16" 24"24'-5" 27'-11" 30'-9"600S125-54 (50 KSI) 600S125-54 (50 KSI) 600S125-54 (50 KSI) 12" 16" 24"26'-2" 30'-0" 33'-0"600S125-68 (50 KSI) 600S125-68 (50 KSI) 600S125-68 (50 KSI) 12" 16" 24"28'-8" 32'-9" 36'-1"800S125-43 800S125-43 800S125-43 12" 16" 24"30'-9" 35'-2" 38'-9"800S125-54 (50 KSI) 800S125-54 (50 KSI) 800S125-54 (50 KSI) 12" 16" 24"33'-4" 38'-1" 41'-11"800S125-68 (50 KSI) 800S125-68 (50 KSI) 800S125-68 (50 KSI) NOTE: ALL STUD INFORMATION IS BASED ON: STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) ICC ESR-3064P US E F O R F U R R I N G P U R P O S E S O N L Y , U . O . N . IN D I C A T E S T H A T W E B S T I F F E N E R S A R E R E Q U I R E D A T E N D S (EXAMPLE: 6" = 600 X 1/100 INCHES) ALL MEMEBER DEPTHS ARE TAKEN IN 1/100 INCHES. FOR ALL "T" SECTIONS MEMBER DEPTH IS THE INSIDE DIMENSION. MEMBER DEPTH:FLANGE WIDTH: (EXAMPLE: 1 5/8" = 1.625" ~ 162 X 1/100 INCHES) ALL FLANGE WIDTHS ARE TAKEN IN 1/100 INCHES. STYLE: (EXAMPLE: STUD OR JOIST SECTION = S) THE FOUR ALPHA CHARACTERS UTILIZED BY THE DESIGNATOR SYSTEM ARE: (EXAMPLE: 0.054 IN. = 54 MILS; 1 MIL =1/1000 IN.) MATERIAL THICKNESS IS THE MINIMUM BASE METAL THICKNESS IN MILS. MINIMUM BASE METAL THICKNESS REPRESENTS 95% OF THE DESIGN THICKNESS. MATERIAL THICKNESS: S = STUD OR JOIST, T = TRACK, U = CHANNEL, F = FURRING - 600 S 162 54 IN D I C A T E S T H A T W E B S T I F F E N E R S A R E R E Q U I R E D A T A L L SU P P O R T P O I N T S A N D C O N C E N T R A T E D L O A D S x x x x x x x 16 GA. METAL STUD 16" O.C. @ ALL BACKING STUD TRACKS 16 GAUGE X 6" METAL FLAT STRAP W = MAX. 100 lb. PER STUD. (2) #8-1/2" SELF-DRILLING SMS FASTENERS PER STUD 400S162-54 HORIZONTAL BRACE. STRADDLE STUD BELOW AND FASTEN TO TOP TRACK WITH (4) #8 SHEET METAL SCREWS (2 EA. SIDE OF STUD) METAL STUD FRAMED WALL 3'-0" MIN.10'-0" MAX . END OF WALL PAINTED BLACK SILL BELOW NON-RATED INTERIOR WALL, PER WALL TYPES OF MULLION AND WALL FRY DRYWALL MOLDING ENCLOSURE EXTERIOR WINDOW SYSTEM BLACK NEOPRENE GASKET COMPRESSED AT LEAST 20% OR APPROVED SEALANT AT RATED PARTITIONS R-13 INSULATION WHERE OCCURS, FULL HEIGHT PARTITION AS SCHEDULED WITH 5/8" THICK GYP. BD. BOTH SIDES (FULL LENGTH X FULL HEIGHT) FLOOR LINE ACOUSTICAL SEALANT EXISTING DECK LINE I8.1 13 BOTTOM TRACK FASTENED TO FLOOR @ 16" O.C. MAX. SLIPTRACK FASTENED TO DECK @ 16" O.C. MAX. WALL BASE WHERE OCCURS, SEE FINISH PLANS I8.1 8SIM. SMALL OFFICE OPEN OFFICE SIM. PARTIAL HEIGHT PARTITION AS SCHEDULED WITH 5/8" GYP. BD. w/ PAINTED FINISH, ONE SIDE ONLY. (FULL LENGTH X FULL HEIGHT) CEILING TYPE AND HEIGHT PER CEILING PLAN NOTE:VERIFY WITH STRUCTURAL 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 3 5 P M KM CB/AB SDG22-6057-00 DE T A I L S I8.1 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 SCALE: 1 1/2" = 1'-0" BWALL TYPE -B- SCALE: 1 1/2" = 1'-0" AWALL TYPE -A- SCALE: 1 1/2" = 1'-0"FWALL TYPE -F- SCALE: 3" = 1'-0" LWALL TYPE -L- SCALE: 3" = 1'-0" 9WALL SWAY BRACE SCALE: 3" = 1'-0" 13WALL BASE SCALE: 3" = 1'-0" 8NON-RATED WALL HEAD SCALE: 1" = 1'-0" 6WALL TYPE NOTES SCALE: 1" = 1'-0" 7DESIGN BUILD METAL STUD SCALE: 12" = 1'-0" 12LIMITING WALL HEIGHT TABLE-L/240 SCALE: 12" = 1'-0" 15BACKING DETAIL FOR MISC. EQUIP. SCALE: 12" = 1'-0" 10HORIZONTAL WALL BRACE SCALE: 3" = 1'-0"14PARTITION AT WINDOW SCALE: 1 1/2" = 1'-0" 16DOUBLE STUD PARTITION DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 18 362S125 SECTION: (MIL) 4 PSF LATERAL SUPPORT OF COMPRESSION FLANGE UNSUPPORTED JOIST SPACING (IN.) O.C. JOIST SPACING (IN.) O.C. 12'-8" 12" 16" 24" 10'-0"11'-7" 9'-3" 12" 16" 24" 7'-7" 8'-7" MID-SPAN 27 362S125 15'-0" 12'-4"13'-11" 10'-8" 8'-10" 9'-10" 30 362S125 15'-6" 12'-10"14'-4" 11'-0" 9'-1" 10'-2" 33 362S125 16'-2" 13'-3"14'-10" 11'-5" 9'-5" 10'-7" 43 362S125 17'-9" 14'-8"16'-5" 12'-8" 10'-5" 11'-8" 27 362S137 17'-2" 14'-3"15'-11" 12'-0" 10'-0" 11'-2" 33 362S137 18'-4" 15'-2"16'-11" 12'-11" 10'-8" 11'-11" 43 362S137 20'-0" 16'-7"18'-6" 14'-3" 11'-8" 13'-2" 33 362S162 20'-10" 16'-6"18'-11" 14'-8" 12'-2" 13'-7" 43 362S162 22'-8" 18'-0"20'-7" 16'-2" 13'-4" 14'-11" 27 400S125 15'-5" 12'-9"14'-3" 10'-11" 9'-1" 10'-1" 30 400S125 16'-0" 13'-2"14'-9" 11'-4" 9'-4" 10'-5" 33 400S125 16'-7" 13'-8"15'-3" 11'-9" 9'-8" 10'-10" 43 400S125 18'-3" 15'-0"16'-10" 13'-0" 10'-8" 12'-0" 27 400S137 17'-7" 14'-8"16'-4" 12'-4" 10'-3" 11'-5" 33 400S137 18'-9" 15'-7"17'-4" 13'-3" 10'-11" 12'-3" 43 400S137 20'-7" 17'-0"19'-0" 14'-7" 12'-0" 13'-6" 33 400S162 21'-5" 17'-9"19'-10" 15'-0" 12'-6" 13'-11" 43 400S162 23'-4" 19'-4"21'-7" 16'-7" 13'-8" 15'-3" 27 600S125 17'-11" 14'-9"16'-6" 12'-5" 10'-4" 11'-6" 33 43 30 600S125 600S125 600S125 18'-5" 15'-3"17'-1" 12'-9" 10'-8" 11'-10" 18'-11" 15'-10"17'-7" 13'-2" 11'-0" 12'-3" 20'-6" 17'-0"19'-0" 14'-6" 11'-11" 13'-4" 33 600S137 21'-5" 17'-10"19'-10" 14'-11" 12'-5" 13'-9" 43 600S137 23'-1" 19'-3"21'-5" 16'-3" 13'-5" 15'-0" 33 600S162 24'-5" 20'-5"22'-8" 16'-11" 14'-1" 15'-8" 43 600S162 26'-4" 21'-11"24'-4" 18'-5" 15'-3" 17'-0" CEILING SPAN TABLE NOTES: 1. VALUES ARE FOR SINGLE SPANS. 2. ALLOWABLE CEILING SPAN CALCULATIONS BASED ON 33KSI YIELD STRENGTH STEEL. 3. FOR FULLY BRACED CEILINGS, USE MID-SPAN BRACED VALUES. 4. END BEARING LENGTH = 1" MINIMUM. (EXAMPLE: 6" = 600 X 1/100 INCHES) ALL MEMEBER DEPTHS ARE TAKEN IN 1/100 INCHES. FOR ALL "T" SECTIONS MEMBER DEPTH IS THE INSIDE DIMENSION. MEMBER DEPTH:FLANGE WIDTH: (EXAMPLE: 1 5/8" = 1.625" ~ 162 X 1/100 INCHES) ALL FLANGE WIDTHS ARE TAKEN IN 1/100 INCHES. STYLE: (EXAMPLE: STUD OR JOIST SECTION = S ) THE FOUR ALPHA CHARACTERS UTILIZED BY THE DESIGNATOR SYSTEM ARE: (EXAMPLE: 0.054 IN. = 54 MILS; 1 MIL =1/1000 IN.) MATERIAL THICKNESS IS THE MINIMUM BASE METAL THICKNESS IN MILS. MINIMUM BASE METAL THICKNESS REPRESENTS 95% OF THE DESIGN THICKNESS.S = STUD OR JOIST, T = TRACK, U = CHANNEL, F = FURRING NOTE: ALL JOIST INFORMATION IS BASED ON STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) ICC ESR-3064P - MATERIAL THICKNESS: 600 S 162 54 IN D I C A T E S T H A T W E B S T I F F E N E R S A R E R E Q U I R E D A T E N D S SUSPENDED CEILING GRID LIGHT FIXTURE (LESS THAN 56 LBS.) LATERAL FORCE BRACING MEMBERS MUST BE SPACED A MINIMUM OF 6" FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZ. FORCES. BRACING WIRES MUST BE ATTACHED TO THE GRIDAND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL LOADS, WHICHEVER IS GREATER, WITH A SAFETY FACTOR OF 2. PROVIDE MINIMUM OF 2 SCREWS AT OPPOSIT CORNERS OF SUPPORT WIRES, OR SCREW ON T-BAR SAFETY CLIPS AT SIDES OR ENDS. TWO (2) NO. 12 GAUGE WIRES MUST BE SECURED FROM LIGHT & MECHANICAL FIXTURES AT OPPOSING CORNERS ALONG THE FIXTURE'S DIAGONAL. WIRES MAY BE SLACK. WHEN HEAVY-DUTY CEILING SYSTEMS ARE USED, SUPPLEMENTAL HANGERS ARE NOT REQUIRED IF A 48" MODULAR HANGER PATTERN IS FOLLOWED. HEAVY-DUTY CEILING SYSTEMS ACOUSTICAL CEILING TILE. WITH WALL ANGLE. 2 1/2" METAL STUD. TYPE "X" GYPSUM BOARD TAPED AND FINISH SMOOTH FOR GLOSS PAINT FINISH.SE E R E F L E C T E D C E I L I N G P L A N WALL OR SOFFIT CLOSURE ANGLE MOLDING 7800 ACOUSTICAL PANEL SUSPENDED CEILING GRID TIGHT SCREW SEISMIC CLIP SYSTEM ANCHOR TO WALL OR SOFFIT BY #6 SCREWS AT 24" O.C. PERIMETER HANGER WIRE AT ALL MAIN RUNNERS AND CROSS TEES "ATTACHED WALL" ARMSTRONG BERC2 ICC ESR-1308 "ATTACHED WALL" USG ASM7 ICC ESR-1222 OR HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED "ATTACHED WALL" CHICAGO METALIC ICC ESR-2631 OR 8" MAX. 8" MAX. 7/8" WALL OR SOFFIT CLOSURE ANGLE MOLDING 7800 WHERE WALL REMAINS UNATTACHED TO CLOSURE ANGLE, 3/4" CLEARANCE TO BE MAINTAINED ACOUSTICAL PANEL SUSPENDED CEILING GRID LOOSE SCREW 8" MAX. "UNATTACHED WALL" ARMSTRONG BERC2 ICC ESR-1308 SEISMIC CLIP SYSTEM ANCHOR TO WALL OR SOFFIT BY #6 SCREWS AT 24" O.C.PERIMETER HANGER WIRE AT ALL MAIN RUNNERS AND CROSS TEES HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED 7/8" 3/4" 8" MAX. 3/4" "UNATTACHED WALL" USG ASM7 ICC ESR-1222 "UNATTACHED WALL" CHICAGO METALIC ICC ESR-2631 OR OR ARMSTRONG SEISMIC JOINT CLIP WORK WITH ARMSTRONG 15/16" AND 9/16" GRID SYSTEMS. (PRELUDE, SUPRAFINE AND SILHOUETTE MAIN BEAM: SJMR CROSS TEE: SJCG SILHOUETTE AND INTERLUDE CROSS TEE: SJCSI ICC ESR-1308 OR USG ACM7 ICC ESR-1222 OR CHICAGO METALIC SST ICC ESR-2631 HORIZONTAL SEISMIC SLOT VERTICAL POSITIONING STAMP (ARMSTRONG "SJCG" SHOWN) SEISMIC JOINT CLIP TWO PIECE UNIT W/ SLOTS SUSPENDED CEILING SPRINKLER HEAD, SEE FIRE PROTECTION DRAWINGS NOTE: PROVIDE 2 INCHES OVER SIZED TRIM RINGS FOR SPRINKLERS (AND OTHER PENETRATIONS) TO ALLOW FOR AT LEAST 1" OF MOVEMENT IN ALL DIRECTIONS. MIN. 2" MI N . 1 " . SUSPENDED 5/8" GYP. BOARD CEILING USE WATER RESISTANT GYP. BD. IN RESTROOMS OR WET AREAS. 1 1/2" CHANNELS AT 4'-0" O.C. WHERE CEILING IS GREATER THAN 8'-0" IN WIDTH, PROVIDE 1 1/2" COLD ROLLED STEEL "C" CHANNELS PERPENDICULAR TO RUNNERS. 7/8" HAT TRACK FURRING. #8 HANGER WIRE TYP. TO UNDERSIDE OF STRUCTURE ABOVE. SE E R E F . C E I L I N G P L A N FO R C E I L I N G H E I G H T S STEEL DECK TOP TRACK WITH POWER-DRIVEN FASTENERS AT 16"O.C. MAX. ICC-ESR-1752 3-5/8" METAL STUDS @ 24" MAX O.C. WITH TOP AND BOTTOM TRACKS. MIN 12" WIDE OVER 2 FLUTE SPAN 14 GA. GSM CONTINUOUS ENCLOSURE SECURED TO DECK WITH POWER- DRIVEN FASTENERS ICC-ESR-1752 WALL PERPENDICULAR TO FLUTES WALL PARALLEL TO FLUTES THE FOLLOWING SPANS ARE BASED UPON STUDS HAVING A 1-5/8" LEG WITH A 3/8" RETURN. DOUBLE STUDS ARE CONNECTED TOGETHER IN THE SHAPE OF A , WITH ONE #6 SHEET METAL SCREW AT 16" O.C.. ATTACH THE METAL STUD TO THE T-BAR MAIN RUNNER WITH TWO #8 SCREWS. SEE DETAILS FOR ATTACHMENT TO STRUCTURE ABOVE. DBL 1-5/8 X 20 GA STEEL STUDS 3-5/8" X 20 GA. STUDS- SCREWED W/ 7/16" 9 GA. FRAMING SCREWS @ 24" O.C. STAGGERED- SANDWICH MAIN RUNNER BACK. & ATTACH W (3) 7/16" FRAMING SCREWS. PRE-MANUFACTURED STRUTS MAY ONLY BE USED IF ENGINEERING IS APPROVED BY THE BUILDING DEPARTMENT. GC TO SUBMIT FOR APPROVAL. METAL STUDS: MANUFACTURED STRUTS: MAIN RUNNER 2" MAX 1-5/8 X 20 GA. MAIN RUNNER TO 15'-0" TO 15'-0" TO 12'-0" SUSPENDED CEILING SYSTEM, SEE REFLECTED CEILING PLAN FOR SPECIFICATIONS. ICC ESR-2631 LARR #24299 (CHICAGO METALLIC), OR ICC ESR-1222 LARR #25764 (USG INTERIORS), OR ICC ESR-1308 LARR #25032 (WORTHINGTON ARMSTRONG VENTURE) CIRCLE INDICATES REQUIRED LOCATION OF COMPRESSION STRUTS. SEE BELOW. 20GA. MTL. STD COMPRESSION STRUT @ EA. SET OF BRACING WIRES W/(2) #8 SHEET MTL. SCREWS TO THE GRID, SPAN PER TABLE ABOVE. SUSPENDED CEILING SYSTEM. SEE CEILING PLAN. (2) STUD ORIENTATION 12GA. BRACING W/4 TIGHT TURNS IN 1 1/2" EACH END. SPLAY WIRE BRACING IN CLUSTERS OF FOUR WIRES ATTACHED TO MAIN RUNNER WITHIN 2" OF A CROSS TEE SECTION. CROSS RUNNER LATERAL FORCE BRACING: A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. LATERAL FORCE BRACING SHALL BE 12 FEET ON CENTER (MAXIMUM) AND BEGIN NO FARTHER THAN 6 FEET FROM WALLS. LATERAL FORCE BRACING MEMBERS MUST BE SPACED A MINIMUM OF 6" FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZ. FORCES. BRACING WIRES MUST BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL LOADS, WHICHEVER IS GREATER, WITH A SAFETY FACTOR OF 2. ATTACHED UNATTACHED UN A T T A C H E D AT T A C H E D 2-1/2" X 20 GA TO 13'-6" DBL 2-1/2" X 20 GA CEILING SYSTEMS ARE TO BE ATTACHED ONLY AT 2 ADJACENT WALLS OR SOFFITS 12GA. VERTICAL HANGER WIRE @ 4'-0" O.C. EACH WAY (4' O.C. AT MAIN RUNNER) MINIMUM 3 TIGHT TURNS IN 1-1/2" BOTH ENDS TYPICAL THE FOLLOWING INSTALLATION DETAILS ARE TO BE CONSIDERED TO BE COMPLYING WITH THE ABOVE REQUIREMENTS. NOTES: 1. WHERE THE ROOF SYSTEM IS COMPOSED OF WOOD BEAMS, PURLINS, AND SUB-PURLINS, THE 2 X 4 SUB-PURLINS ARE NOT TO BE CONSIDERED AS STRUCTURAL MEMBERS SUPPORTING THE ROOF. 2. CEILING SUSPENSION SYSTEM SHALL COMPLY WITH 808 AND 2506.2.1. COMPONENTS SHALL BE ASTM "HEAVY DUTY" CLASS. 3. THE COMPRESSION STRUT SHALL BE VERTICAL, AND SHALL NOT HANG MORE THAN 1 IN 6 OUT-OF- PLUMB. ACOUSTICAL CEILING SUSPENSION SYSTEM LATERAL FORCE BRACING AND SUSPENSION LIGHT FIXTURE FIRE SPRINKLER 6' - 0 " MA X . 1 2 ' - 0 " OC T Y P . 12'-0" OC TYP. * SEISMIC JOINT IF REQ'D. PER PLAN * = 45 DEGREES* ** I8.2 6 I8.2 4 12 I8.2 11 I8.2 I8.2 3 SUSPENDED ACOUSTICAL CEILING, SEE RCP BRACE TO STRUCTURE, PER WALL TYPE 45 °INSULATION WHERE OCCURS, SEE RCP SCRIBE WALL BOARD TO CEILING GRID AND TRIM NEAT AND TRUE WALL TO UNDERSIDE OF CEILING DECK LINE 5/8" GYPSUM BOARD OVER METAL CEILING JOISTS, SEE METAL JOIST TABLE FOR SPACING LARR # 25889 CEILING WALL ANGLE SUSPENDED ACOUSTICAL CEILING, SEE RCP MI N . 6" SUSPENDED ACOUSTICAL CEILING GYPSUM BOARD CEILING 2 1/2" METAL STUD. TYPE "X" GYPSUM BOARD TAPED AND FINISH SMOOTH FOR GLOSS PAINT FINISH. SUSPENDED GRID AND ACOUSTIC TILE PER PLAN. PROVIDE 18" GA. DIAGONAL BRACING@ 4'-0" O.C. ATTACHED WITH (3) #10 SMS , TYP. METAL STUD CEILING JOISTS, TYP. SEE ALLOWABLE SPAN TABLE THIS SHEET.SE E R C P 1 ' - 0 " OVERHANG +/-1'-6" 5/8" THICK GYP. BOARD CEILING, PAINTED PER PLAN. +/ - 6 " +/ - 6 " ACOUSTICAL CEILING TILE WITH WALL ANGLE RUN GYP. BD. TO UNDERSIDE OF DECK AND FINISH AS REQUIRED. TYPE "X" GYPSUM BOARD TAPED AND FINISH SMOOTH FOR GLOSS PAINT FINISH 2' - 0 " SEE PLAN 1'-6" SE E P L A N 6" 45°METAL STUD BRACING @ 24" O.C. METAL STUD BRACING @ 24" O.C. WHERE CEILING TO DECK EXCEEDS WIDTH OF SOFFIT METAL DEFLECTION TRACK. GAUGE TO MATCH GAUGE OF WALL STUD. FASTEN TO DECK WITH POWER- DRIVEN FASTENERS @ 24" O.C. AT COMPOSITE DECK OPEN CEILING AREA EXTERIOR CONCRETE WALL SUSPENDED ACOUSTICAL CEILING, SEE RCP EXTERIOR WINDOW SYSTEM POWER DRIVEN ANCHOR AT STUD SE E R E F . C E I L I N G P L A N FO R C E I L I N G H E I G H T S SHEET METAL. GAUGE TO BE CONFIRMED BY CONTRACTOR TO PREVENT DEFLECTION AND OIL CANNING. FINISH TO BE APPROVED BY BUILDING OWNER. METAL STUD. TYPE "X" GYPSUM BOARD TAPED AND FINISH SMOOTH FOR PAINT FINISH. ACOUSTICAL CEILING TILE. WITH WALL ANGLE. OPEN TO STRUCTURE 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 3 8 P M K. BURGER CB / JG SDG22-6057-00 DE T A I L S I8.2 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 N.T.S. 2ALLOWABLE CEILING SPANS-L/240 N.T.S. 4 LIGHT FIXTURE@SUSPENDED CLNG. SCALE: 3" = 1'-0" 13CEILING TRANSITION SCALE: 3" = 1'-0" 12ATTACHED CLOSURE ANGLE SCALE: 3" = 1'-0" 11UNATTACHED CLOSURE ANGLE N.T.S. 3SEISMIC JOINT CLIP SCALE: 3" = 1'-0" 6SPRINKLER CEILING PENETRATION SCALE: 3" = 1'-0" 15SUSPENDED GYP. BOARD CEILING SCALE: 3" = 1'-0" 16TOP OF WALL AT CEILINGS SCALE: 12" = 1'-0" 10SUSPENDED CEILING SCALE: 1 1/2" = 1'-0" 19CEILING TRANSITION TO WALL SCALE: 3" = 1'-0" 14 CEILING TRANSITION SCALE: 1 1/2" = 1'-0"17 CONF. ROOM - TRANSITION BETWEEN DRYWALL & TBAR CEILINGS SCALE: 1" = 1'-0"18SOFFIT @ RECEPTION AREA SCALE: 1 1/2" = 1'-0" 5SOFFIT AT PERIMETER WALL DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L SCALE: 3" = 1'-0" 20CEILING HEADER TRANSITION 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 FLOOR PLAN SEE 5/8" TYPE 'X' GYPSUM BOARD EACH SIDE OVER METAL STUD. SEE STUD TABLE FOR SIZE AND SPACING. INSULATION WHERE OCCURS. FIXED GLASS. DOOR FRAME PER SCHEDULE. DOOR PER SCHEDULE. FIRE EXTINGUISHER CABINET (F.E.C.) .VERIFY ROUGH OPENING W/ MFG. IN FIELD. . (2) LAYERS 5/8" TYPE "X" GYP. B.D. BEHIND F.E.C. W/FURRING CHANNELS TO MAINTAIN 1-HR RATING. 5/8 " TYPE "X" GYP. BD. TYP. VARIES PER MANUFACTURER. (4"MAX) METAL STUDS WHERE OCCUR. ONE-HOUR WALL INSTALLATION NON-RATED INSTALLATION NOTE : MOUNT FEC SO HIGHEST OPERABLE PART OF CABINET OR EXTINGUISHER DOES NOT EXCEED 48" AFF. DOOR JAMB DOOR IN OPEN POSITION 40 " 6" SIDELITE PARTIAL PLAN LIGHT SWITCH AND/OR SENSOR THERMOSTAT TOP OF OUTLET BOX NOTE: PROVIDE METAL BLOCKING BETWEEN STUDS TO MOUNT LIGHT SWITCH/SENSOR & THERMOSTAT AT DIMENSION INDICATED DOOR HANDLE (OR @ GLASS FRONT) NOTE: PROVIDE METAL BLOCKING BETWEEN STUDS TO MOUNT LIGHT SWITCH/SENSOR & THERMOSTAT AT DIMENSION INDICATED. 6" 40 " LIGHT SWITCH AND/OR SENSOR THERMOSTAT DOOR HANDLE INSULATION WHEN OCCURS. 5/8" TYPE 'X' GYP. BD. EACH SIDE OVER METAL STUD. SEE STUD TABLE FOR SIZE AND SPACING. METAL RACK. 3-5/8" METAL STUD NESTED IN METAL TRACK. ALUMINIUM WINDOW FRAME. FIXED GLASS. 4 7/8" 5/ 8 " 2 " DOOR PER SCHEDULE 16 GA. HOLLOW METAL FRAME METAL STUD NESTED IN METAL TRACK BACKER ROD AND SEALANT AT BOTH SIDES 5/8" TYPE "X" GYPSUM BOARD EACH SIDE OVER METAL STUD. SEE STUD TABLE FOR SIZE AND SPACING INSULATION WHERE OCCURS DO O R D I M . SE E S C H E D U L E FIXED GLASS ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT CONCRETE SLAB FINISH FLOOR MATERIAL SHIM AS REQUIRED SEE CEILING PLAN FOR CEILING HEIGHT 3/4" MELAMINE SHELF (1" IF OVER 3'-0" WIDE), TYP. - PROVIDE EDGE BANDS AT FRONT & BACK 1/4" MELAMINE BACK, TYP. 3/4" FRENCH CLEAT FASTENED TO STUDS, TYP. 3/4" PLASTIC LAMINATE CABINET DOOR, TYP. - FINISH BOTH SIDES & PROVIDE EDGE BAND AT ALL 4 EDGES 3/4" MELAMINE TOP W/EDGE BAND 3/4" PLASTIC LAMINATE DRAWER FACE 3/4" PLASTIC LAMINATE COUNTERTOP 1/2" MELAMINE DRAWER BACK & SIDES 3/4" PLASTIC LAMINATE BACKSPLASH WITH 1/4" RADIUSED COVE 3/16" DIA. HOLES FOR SHELF SUPPORTS, TYP. 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. FRAMELESS CONCEALED HINGE, TYP. PLASTIC LAMINATE BASE 3/4" MELAMINE DRAWER BOTTOM 3/4" x 3" STRETCHER, TYP. HARDWARE PER ELEVATIONS, MOUNTED HORIZONTALLY, WITH COUNTER-SUNK SCREWS & CAPS, TYP. - PROVIDE SILENCERS AT DOORS CLEAR 1'-3" 1'-5" 1 1 / 2 " 3' - 0 " 2' - 2 " VA R I E S 2' - 1 0 " 4" 3" 8' - 0 " 4" 2'-0" 1/2" EQ . EQ . 1 1 / 2 " 5" 1 1 / 2 " TY P . 1/ 8 " G A P GYP. SOFFIT PER RCP SEE CEILING PLAN FOR CEILING HEIGHT 3/4" MELAMINE SHELF (1" IF OVER 3'-0" WIDE), TYP. - PROVIDE EDGE BANDS AT FRONT & BACK 1/4" MELAMINE BACK, TYP. 3/4" FRENCH CLEAT FASTENED TO STUDS, TYP. 3/4" PLASTIC LAMINATE CABINET DOOR, TYP. - FINISH BOTH SIDES & PROVIDE EDGE BAND AT ALL 4 EDGES 3/4" MELAMINE TOP W/EDGE BAND 3/4" PLASTIC LAMINATE COUNTERTOP 3/16" DIA. HOLES FOR SHELF SUPPORTS, TYP. 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. FRAMELESS CONCEALED HINGE, TYP. PLASTIC LAMINATE BASE OPEN ABOVE 3/4" x 3" STRETCHER, TYP. HARDWARE PER ELEVATIONS, MOUNTED HORIZONTALLY, WITH COUNTER-SUNK SCREWS & CAPS, TYP. - PROVIDE SILENCERS AT DOORS CLEAR 1'-3" 2'-0" 1'-5" 3" 4" 2' - 1 0 " 2' - 2 " 3' - 0 " 8' - 0 " VA R I E S 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " TY P . 1 / 8 " G A P 3/4" PLASTIC LAMINATE COUNTERTOP 3/4" PLASTIC LAMINATE BACKSPLASH WITH 1/4" RADIUSED COVE DRAIN & HOT WATER PIPING TO BE WRAPPED WITH INSULATION AS REQUIRED ACCESSIBLE INTEGRAL TOE-KICK STAINLESS STEEL SINK W/OFFSET DRAIN, 6" DEEP MAX. 3/4" PLASTIC LAMINATE FALSE FRONT TO ALIGN WITH ADJACENT DRAWERS FOOD WASTE DISPOSER AT LOCATIONS INDICATED PER PARTITION PLAN FRAMELESS CONCEALED HINGE, TYP. 3/4" x 3" STRETCHER, TYP. 1/4" MELAMINE BACK, TYP. 2'-0" 4" 1/2" 3" 4" 1 / 2 " 1 1 / 2 " 5" 1 1 / 2 " TY P . 1/ 8 " G A P TO T O P O F O P P E R M O S T S U R F A C E 2' - 1 0 " KN E E C L E A R A N C E 2' - 3 " M I N . KNEE/TOE CLEARANCE 1'-5" MIN. 1:6 MAX. SLOPE MIN. 8" MAX. 6" MI N . 9" 3/4" PLASTIC LAMINATE COUNTERTOP 3/4" PLASTIC LAMINATE BACKSPLASH WITH 1/4" RADIUSED COVE 3/4" x 2" CLEAT 3/4" SUBTOP ADJACENT CABINET BEYOND UNDER-COUNTER EQUIPMENT 2' - 1 0 " 1 1 / 2 " 2'-0" 1/2" 4" P.LAM. WORK SURFACE WITH EASED EDGE P.LAM. OVER SUBSTRATE, TYP. FLOOR RUNNER GROMMET WITH PLASTIC SLEEVE - SPACE AS NEEDED 2-1/2"x2-1/2"x1/4" STEEL ANGLE SUPPORT @ 24" O.C.. AND AT EACH COUNTER END. WALL, SEE PARTITION PLAN ON E L E V . 4" U . N . O . SE E I N T E R I O R E L E V A T I O N S 2'-0" 3/4" MELAMINE SHELF (1" IF OVER 3'-0" WIDE), TYP. - PROVIDE EDGE BANDS AT FRONT & BACK 3/4" PLASTIC LAMINATE DRAWER FACE 3/4" PLASTIC LAMINATE COUNTERTOP 1/2" MELAMINE DRAWER BACK & SIDES 3/16" DIA. HOLES FOR SHELF SUPPORTS, TYP. 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. PLASTIC LAMINATE BASE 3/4" MELAMINE DRAWER BOTTOM 3/4" x 3" STRETCHER, TYP. 2' - 1 0 " 4" 3" 1/2" EQ . EQ . 1 1 / 2 " 5" 1 1 / 2 " TY P . 1/ 8 " G A P SEE CEILING PLAN FOR CEILING HEIGHT 4" BRUSHED STAINLESS WIRE PULLS MTD. HORIZONTALLY, WITH COUNTER-SUNK SCREWS & CAPS. PROVIDE SILENCERS. 1/4" MELAMINE BACK 3/4" FRENCH CLEAT FASTENED TO STUDS, TYP. 3/4" P.LAM. CABINET DOOR - FINISH BOTH SIDES & PROVIDE EDGE BAND AT ALL 4 EDGES 3/4" MELAMINE TOP W/EDGE BAND FRAMELESS CONCEALED HINGE P.LAM. SPACER 3/4" MELAMINE SHELF (1" IF OVER 3'-0" WIDE) - PROVIDE EDGE BANDS AT FRONT & BACK REFRIGERATOR/ VENDING MACHINE 3/4" P.LAM. BOTTOM W/EDGE BAND 3/16" DIA. HOLES FOR SHELF SUPPORTS GYP. BD. SOFFIT - SEE R.C.P. 1" 1 1 / 2 " U.O.N. 2'-6" VA R I E S VE R I F Y +/ - 8 ' - 0 " VE R I F Y 1' - 9 " VE R I F Y W / T E N A N T 6' - 3 " A . F . F . 24"3/4" PLAM SLIDE OUT BIN CONTAINER BOX ATTACHED TO FRONT w/ FULL EXTENSION HEAVY DUTY GLIDES 3/4" PLASTIC LAMINATE FACE SCHEDULED COUNTERTOP 1/2" MELAMINE DRAWER BACK & SIDES PROVIDE TWO WHITE TALL BINS PER PULL OUT 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. PLASTIC LAMINATE BASE 3/4" x 3" STRETCHER, TYP. 3" 4" 2' - 1 0 " 2'-0" 3" 3' - 6 " 2'-6" 2' - 6 " 1' - 0 " RUBBER BASE PLASTIC LAMINATE OVER 3/4" PLYWD. L-METAL BRACKET @ 48" O.C. MAX. WHITE GROMMET, VIF 1/4" DIA. X 3/4" LONG HILTI DROP-IN ANCHOR @ 32" O.C. @ 4" FROM ENDS 2-1/2" 25 GA. MTL. STUD PLASTIC LAMINATE OVER 3/4" PLYWD. 1/4" REVEAL PAINTED SHERWIN WILLIAMS SW 9106 SOLID SURFACE TRANSACTION TOP PLASTIC LAMINATE OVER 3/4" PLYWD. SOLID SURFACE WORKSURFACE 4" PROVIDE 1.5" SSM OVERHANG 1 1 / 2 " SURFACE MOUNT ELECTRICAL AND CONCEAL CONDUIT TO UNDERSIDE OF WORKSURFACE 3" 2' - 1 0 " 2'-6" 2' - 6 " 1 ' - 0 " RUBBER BASE PLASTIC LAMINATE OVER 3/4" PLYWD. L-METAL BRACKET @ 48" O.C. MAX. WHITE GROMMET, VIF 1/4" DIA. X 3/4" LONG HILTI DROP-IN ANCHOR @ 32" O.C. @ 4" FROM ENDS 2-1/2" 25 GA. MTL. STUD 1/4" REVEAL PAINTED SHERWIN WILLIAMS SW 9106 PLASTIC LAMINATE OVER 3/4" PLYWD. SOLID SURFACE WORKSURFACE 4" SOLID SURFACE TRANSACTION TOP PROVIDE 1.5" SSM OVERHANG 1 1 / 2 " SURFACE MOUNT ELECTRICAL AND CONCEAL CONDUIT TO UNDERSIDE OF WORKSURFACE 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. PLASTIC LAMINATE AS SCHEDULED 3/4" PLASTIC LAMINATE DRAWER FACE 3/4" MELAMINE DRAWER BOTTOM 1/2" MELAMINE DRAWER BACK & SIDES 2'-0" 3" 1/2" EQ E Q 2" 2" 2" 6" 6" 1 1 / 2 " TY P . 1/ 8 " G A P , FULL HEIGHT TILE BACKSPLASH PER FINISH PLAN 4" PLASTIC LAMINATE BASE PE R E L E V A T I O N MICROWAVE OVEN BY OTHERS 2'-0" 2' - 1 0 " 4" 1 ' - 0 " 1 " 1' - 4 " 1 1 / 2 " 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. 1/2" MELAMINE DRAWER BACK & SIDES PLASTIC LAMINATE BASE 3" 3/4" MELAMINE SHELF (1" IF OVER 3'-0" WIDE), TYP. - PROVIDE EDGE BANDS AT FRONT & BACK PLASTIC LAMINATE AS SCHEDULED 1/4" PLASTIC LAMINATE BACK 3/4" MELAMINE SHELF (1" IF OVER 3'-0" WIDE), TYP. - PROVIDE EDGE BANDS AT FRONT & BACK 1/4" MELAMINE BACK, TYP. 3/4" FRENCH CLEAT FASTENED TO STUDS, TYP. 3/4" PLASTIC LAMINATE CABINET DOOR, TYP. - FINISH BOTH SIDES & PROVIDE EDGE BAND AT ALL 4 EDGES 3/4" MELAMINE TOP W/EDGE BAND 3/16" DIA. HOLES FOR SHELF SUPPORTS, TYP. 2 x 4 WOOD STRETCHERS AT 2'-0" O.C. FRAMELESS CONCEALED HINGE, TYP. PLASTIC LAMINATE BASE 3/4" x 3" STRETCHER, TYP. PER PLAN 3" 4" PE R E L E V A T I O N TY P . 1/ 8 " G A P 3/4" FIXED MELAMINE SHELF, 1" IF OVER 3'-0" WIDE. HARDWARE PER ELEVATIONS, MOUNTED HORIZONTALLY, WITH COUNTER-SUNK SCREWS & CAPS, TYP. - PROVIDE SILENCERS AT DOORS REFER TO DETAIL 21/A8.1 FOR BACKING SUPPORT. GRK 772691120793 CABB8212HP CABINET SCREWES, # 8" X 2-1/2" FINISH WALL SCHLUTER - QUADEC - E FINISH: AE SATIN ANODIZED ALUMINUM TILE SUBSTRATE SCHLUTER - DILEX - AHK FINISH: ACGB BRUSHED CHROME ANODIZED ALUMINUM 39 1 1 S o r r e n t o V a l l e y B l v d , S u i t e # 1 2 0 Sa n D i e g o , C A , 9 2 1 2 1 P 8 5 8 . 6 3 8 . 7 2 7 7 JOB NO.: DRAWN BY.: PA/PM: SHEET TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F W A R E M A L C O M B A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E PT B Y A G R E E M E N T W I T H W A R E M A L C O M B . W R I T T E N D I M E N S I O N S S H A L L T A K E P R E C E D E N C E O V E R S C A L E D D I M E N S I O N S A N D S H A L L B E V E R I F I E D O N T HE J O B S I T E . A N Y D I S C R E P A N C Y S H A L L B E B R O U G H T T O T H E N O T I C E O F W A R E M A L C O M B P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K CAUTION: IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT C: \ U s e r s \ c b u e n d i a \ O n e D r i v e - W a r e M a l c o m b \ D e s k t o p \ D o c u m e n t s \ 6 0 5 7 - A R C H _ c b u e n d i a U 3 X M V . r v t 2/ 3 / 2 0 2 3 4 : 4 5 : 4 1 P M K. BURGER CB / JG SDG22-6057-00 DE T A I L S I8.3 CO R T I C A S A N T A A N A SU I T E S 1 0 0 & 1 1 0 25 0 0 R E D H I L L A V E N U E SA N T A A N A , C A 9 2 7 0 5 SCALE: 3" = 1'-0" 2INTEGRAL DOOR & WINDOW JAMB SCALE: 3" = 1'-0"11FIRE EXTINGUISHER CABINET SCALE: 3/8" = 1'-0" 7LT. SWITCH / T-STAT @ SIDELITE SCALE: 3/8" = 1'-0" 6L.T. SWITCH/T-STAT INSTALLATION SCALE: 3" = 1'-0" 3WINDOW HEAD (JAMB & SILL SIM) SCALE: 3" = 1'-0" 1DOOR HEAD (JAMB SIM.) SCALE: 3" = 1'-0"4WINDOW SILL SCALE: 1" = 1'-0" 13UPPER/LOWER CABINETS SCALE: 1" = 1'-0" 15UPPER/LOWER CAB. W/O DRAWERS SCALE: 1" = 1'-0"16LOWER CABINET AT SINK SCALE: 1" = 1'-0" 18LOWER CAB. AT EQUIP. OPENING SCALE: 1" = 1'-0"19 COUNTERTOP SUPPORT SCALE: 1" = 1'-0"17LOWER CABINETS SCALE: 1" = 1'-0" 5UPPER CABS ABOVE REFR./VEND. SCALE: 1" = 1'-0" 10PULL-OUT BASE CABINET SCALE: 1" = 1'-0" 20RECEPTION DESK - 01 SCALE: 1" = 1'-0" 21RECEPTION DESK SCALE: 1" = 1'-0"8LOWER CABS W/DRAWERS SCALE: 1" = 1'-0" 9LOWER CAB MICRO DA T E RE M A R K S 20 2 2 - 1 2 - 2 0 PL A N C H E C K S UB M I T T A L SCALE: 1" = 1'-0" 23FULL HEIGHT CABINET SCALE: 1 1/2" = 1'-0" 24 TOP OF TILE WAINSCOT, TYP. SCALE: 1 1/2" = 1'-0" 25BASE, TYP. 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments ·Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. ·Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2.Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5.Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6.Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7.Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8.Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9.Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10.Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11.*Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12.Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City Official Requesting Review:City Reference #: __________________________ City / County: _____________________________________Date: __________________________________ Contact Name: _____________________________________E-Mail: __________________________________ Title: _____________________________________ Phone #: _________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 08/30/2021 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23 2500 S Redhill Ave #100 and #110 - 101113828-29 and 20178695 04/20/23