HomeMy WebLinkAbout1218 S Mohawk Dr- need V2 & V3 - 101116729 & 20181043 - Plan20A1PV CIRCUIT 2: 4 MODULES/PARALLEL [(2) AP SYSTEM DS3-L 2 IN 1]112437ROOFTOPGROUND LEVEL -HOUSE EXTERIOR20A20AN2(N) JUNCTION BOXWITH IRREVERSIBLEGROUND SPLICENOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THEGROUNDING / BONDING, GROUND CLAMPS ARE AT EACHEND OF THE EMT CONDUIT WITH THE WIRE THEN FREEAIR'D TO THE GROUND CLAMP ON THE RACKING RAIL(N)100A PV LOADCENTER(N) (11) JA SOLAR JAM54S31-395/MR/(395W) MODULESWITH (6) AP SYSTEM DS3-L 2 IN 1 MICRO-INVERTERATTACHED TO THE BACK OF MODULE1PV CIRCUIT 1: 7 MODULES/PARALLEL [(4) AP SYSTEM DS3-L 2 IN 1]11265MPOINT OF DELIVERY ANDINTERCONNECTION50A100AN3(E) GROUNDINGELECTRODE OR(UFER)BACKFEEDBREAKER(N) VISIBLELOCKABLE2 POLE 60A'KNIFE' ACDISCONNECT3ACDISCONNECTTO BE LOCATEDWITHIN 10' OFMETEREXISTING240V/125AMAIN SERVICE PANELSINGLE PHASEEXISTING WIRE(E) SOLAREDGESE3800H-US INVERTERG GL2NL1(E) (15) SHARP ND224UC1SOLAR MODULES(E) JUNCTION BOXWITH IRREVERSIBLEGROUND SPLICEGSTRING #1 STRING #2 PV CIRCUIT 2: 7 MODULES/SERIESPV CIRCUIT 1: 8 MODULES/SERIES(E) VISIBLELOCKABLE2 POLE 30A'KNIFE' A/CDISCONNECTEXISTING WIRESHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344E-1DESIGN TEMPERATURESASHRAE EXTREME LOW-1°CASHRAE 2% HIGH36°CPV Module Ratings @ STCModule Make/ModelJA SOLARJAM54S31-395/MR/(395W)MODULEMax Power-Point Current (Imp)12.81AMax Power-Point Voltage (Vmp)30.84VOpen-Circuit Voltage (Voc)36.98VShort-Circuit Current (Isc)13.70AMax Series Fuse (OCPD)25ANominal Maximum Power at STC (Pmax)395WMaximum System Voltage1500VVoc Temperature Coefficient-0.275% /°CConduit and Conductor Schedule ~ (75°C Copper Column)TagDescriptionWire Gauge# of ConductorsConduit TypeConduit Size1 AP SYSTEM'S AC BUS CABLE 12 AWG2N/A - Free Air N/A - Free Air1Bare Copper Ground (EGC/GEC)6 AWG1N/A - Free Air N/A - Free Air2 THWN-210 AWG4EMT3/4"2 THWN-2 - Ground8 AWG1EMT3/4"33THWN-28 AWG3EMT3/4"THWN-2 - Ground8 AWG1EMT3/4"Inverter RatingsInverter Make/ModelAP SYSTEM DS3-LMax DC Volt Rating60VPeak Output Power768WMax Nominal Voltage240VMax AC Current3.2AMax OCPD Rating20AMETER # 222014114497EXISTING PV SYSTEM IS RSD COMPLIANTSYSTEM SUMMARYBRANCH #1INVERTERS PER BRANCH4MAX AC CURRENT12.8AMAX AC OUTPUT POWER3072WARRAY STC POWER4345WARRAY PTC POWER4056WMAX AC CURRENT19.20AMAX AC POWER4608WDERATED (CEC) AC POWER3913.75WBRANCH #226.4A1536WMAIN SERVICE PANEL240/120V 1Ø, 3WMAIN BUSS: 125AMAX BREAKER SIZE:(125A X 1.2) - 100A = 50.0A1218 S Mohawk Dr -2018104310/3/2023 N 1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARDREQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION.2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POPRIVETS OR SCREWS OR OTHER APPROVED METHOD.4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING,MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVEWEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT.PERMANENT SIGNAGE NOTES:WARNING!DO NOT RELOCATE THISOVERCURRENT DEVICEPOWER SOURCE OUTPUT CONNECTIONLABEL LOCATION:ADJACENT TO PV BREAKER (IF APPLICABLE).PER CODE(S): CEC 2022: 705.12(B)(3)(2)!DO NOT ADD LOADSPHOTOVOLTAIC SYSTEMCOMBINER PANELWARNINGLABEL LOCATION:PHOTOVOLTAIC AC COMBINER (IFAPPLICABLE).PER CODE(S): CEC 2022: 705.12(B)(3)(3)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICEDISCONNECTING MEANS TO WHICH THE PV SYSTEMSARE CONNECTED.ELECTRICAL SHOCK HAZARDWARNING!LABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): CEC 2022: 706.15(C)(4) &690.13(B)TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:UTILITY SERVICE ENTRANCE/METER, INVERTER/DCDISCONNECT IF REQUIRED BY LOCAL AHJ, OROTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): CEC 2022: 690.56(C)(2),CFC 2022: 1204.5.3POWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNCAUTION:MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 19.20 AMPS240.0 VACPHOTOVOLTAIC AC DISCONNECTLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): CEC 2022: 690.54SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS:2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344E-21218 S MOHAWK DRWARNING!THIS EQUIPMENT FED BY MULTIPLESOURCES. TOTAL RATING OF ALLOVERCURRENT DEVICES, EXCLUDINGMAIN SUPPLY OVERCURRENTDEVICE, SHALL NOT EXCEEDAMPACITY OF BUSBAR.(N) SOLAR PANELS ANDMICRO-INVERTERS ON ROOFLOCATION OF EXISTING ACDISCONNECT & STRING INVERTERPV INTERCONNECTION POINT.LOCATION OF METER MAIN COMBO, ACDISCONNECT & PV LOAD CENTER(E) PV SYSTEM IS RSDCOMPLIANTMAXIMUM AC OPERATING CURRENT(NEW AND EXISTING SYSTEM):NOMINAL OPERATING AC VOLTAGE: 35.20 AMPS240.0 VACPHOTOVOLTAIC AC DISCONNECTLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): CEC 2022: 690.541218 S Mohawk Dr -2018104310/3/2023 1'-6"1'-6"1'-6"1'-6"N3'3'3'3'SCALE: 3/32" = 1'-0"PV SYSTEM SITE PLANPV SYSTEM SIZE:4.345 kW DC LEGENDCONSTRUCTION NOTESRoof Azimuth: 192°Roof Tilt: 19°Roof Section 2NEW SOLAR PANELS(11) JA SOLAR JAM54S31-395/MR/(395W)WITH (6) AP SYSTEM DS3-L MICROINVERTERSMOUNTED TO THE BACK OF MODULESMOUNTED ON COMP SHINGLE ROOF1218 S MOHAWK DRROOF OBSTRUCTIONSSHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344PV-1ACDAC DISCONNECTLCLOAD CENTER(E)SHED STRUCTURE ONPROPERTY1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITHTHE CBC SECTION 1609 TO WITHSTAND A BASIC WINDSPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C.3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ONCENTER. CONNECTION TO STRUCTURE SHALL NOT BEWITHIN 11" OF NAILING PLATES.4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOTOBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDINGROOF VENTS.5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOFSHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE(INCLUDING CABLES UNDERNEATH MODULES ANDRACKING).6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THEFOLLOWING (CRC R324.6, CBC 3111.3.4)6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OFGROUND LADDERS OVER OPENINGS SUCH AS DOORSOR WINDOWS.6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION INLOCATIONS WHERE ACCESS POINT DOES NOTCONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS:TREES, WIRES, OR SIGNS.7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES INCOMPLIANCE WITH 2022 CFC/2021 IFC 1205.2.1.2TOTAL PLAN VIEW AREA FOR NEW SYSTEM = 2145.56 SQFTTOTAL PV AREA = 11(67.79 IN)(44.64 IN)/(144 IN^2) = 231.16 SQFT=(231.16 SQFT/ 2145.56 SQFT)100 = 10.77%TOTAL PV AREA FOR EXISTING SYSTEM=15(65 IN)(40 IN)/(144 IN^2) = 270.83 SQFT=(270.83 SQFT/ 2145.56 SQFT)100 =12.62%TOTAL PV AREA FOR NEW AND EXISTING SYSTEM.(231.16+ 270.83) SQFT/ 2145.56 SQFT = 23.39%TOTAL PV AREA POPULATES 23.39% OF TOTAL PLANVIEW AREA AND IS WITHIN THE 33% REQUIREMENT.WALKWAYDRIVEWAYINVSTRING INVERTERRoof Azimuth: 192°Roof Tilt: 19°Roof Section 1MMETER MAIN COMBOPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINE(E) SERVICE DROPMPV INTERCONNECTION POINT.LOCATION OF METER MAIN COMBO, ACDISCONNECT & PV LOAD CENTERMOUNTED ON EXTERIOR WALL OF ASINGLE FAMILY RESIDENCELOCATION OF "RAPID SHUTDOWN" ACDISCONNECT NEC 690.12ACDLCINVLOCATION OF EXISTING ACDISCONNECT & STRING INVERTER(E) SOLAR SYSTEMCAL-FIRE ROOF LADDERACCESS POINTACDPROPERTY LINEPROPERTY LINECAL-FIRE ROOF LADDERACCESS POINTCAL-FIRE ROOF LADDERACCESS POINT(N) SOLAR SYSTEM(E) UNPERMITTEDPATIO COVERSTRUCTURESigned: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 6'6'NNSCALE: 1/8" = 1'-0"PV SYSTEM MOUNTING DETAILSUNIRAC FLASHLOC FOR COMPSHINGLE @ 72" O.C. MAXPROPOSED EVERESTCROSSRAIL RACKINGPROPOSED JA SOLARJAM54S31-395/MR/(395W) PV SOLAR MODULESEXISTING 2 "X 4" ROOFTRUSSES @ 24"O.C.SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344PV-2EXISTING COMP SHINGLEROOFRoof Azimuth: 192°Roof Tilt: 19°Roof Section 2Roof Azimuth: 192°Roof Tilt: 19°Roof Section 1Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 ROOF SLOPE 910106217PV-3D52011121413151822S-5D431542524238262SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344D4DETAIL (TRANSVERSE)NOT TO SCALED5DETAIL (LONGITUDINAL)NOT TO SCALED1RACKING DETAIL (TRANSVERSE)NOT TO SCALED3RACKING DETAIL (TOP)NOT TO SCALED2RACKING DETAIL (LONGITUDINAL)NOT TO SCALE1. ROOF MATERIAL: COMP SHINGLE2. ROOF STRUCTURE: TRUSSES3. ATTACHMENT TYPE: UNIRAC FLASHLOC4. MODULE MANUFACTURER: JA SOLAR5. MODULE MODEL: JAM54S31-395/MR/(395W)6. MODULE LENGTH: 67.79''7. MODULE WIDTH: 44.64"8. MODULE WEIGHT: 42.99 LBS.9. SEE SHEET S-1 FOR DIMENSION(S)10. MIN. FIRE OFFSET: 18"11. TRUSSES SPACING: 24" O.C.12. TRUSSES SIZE: 2 "X 4" NOMINAL13. LAG BOLT DIAMETER: 5/16 IN.14. LAG BOLT EMBEDMENT: 2.5 IN.15. TOTAL # OF ATTACHMENTS: 3016. TOTAL AREA: 231.16 SQ. FT.17. TOTAL WEIGHT: 472.89 LBS.18. WEIGHT PER ATTACHMENT: 15.76 LBS.19. DISTRIBUTED LOAD: 2.05 PSF20. MAX. HORIZONTAL STANDOFF: 72 IN.21. MAX. VERTICAL STANDOFF:LANDSCAPE: 26 IN., PORTRAIT: 43 IN.22. STANDOFF STAGGERING: YES23. RAIL MANUFACTURER AND MODEL(OR EQUIV.):EVEREST CROSSRAIL24. RAIL WEIGHT: 0.436 PLF.25. MAX. TRUSSES SPAN: 12 FT.26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.PV-3Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344S-1Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344S-2Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344S-3Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344S-4Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 SHEET # T-1 T-2 PV-1 PV-2 PV-3 E-1 E-2 S-1 S-2 S-3 S-4 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET PROJECT INFORMATION PROPERTY OWNER NAME:RAUL GONZALEZ PHONE:- CONTRACTOR NAME:SOLGEN CONSTRUCTION PHONE:(559)442-9887 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (ENERGY) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2020 NATIONAL ELECTRICAL CODE (NEC) 2022 CALIFORNIA FIRE CODE (CFC) COORDINATES: 33.731578, -117.911285 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023 GONZALEZ RESIDENCE License#: C-10 1053344 DESIGNER: OSD CORE ENERGY GROUP. ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 T-1 AERIAL VIEW GONZALEZ RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 4.345 kW DC / 4.608 kW AC TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE MSP SCOPE OF WORK SYSTEM SIZE: STC: 11 X 395W = 4.345kW PTC: 11 X 368.7W = 4.056kW (11)JA SOLAR JAM54S31-395/MR/(395W) MODULES (6)AP SYSTEM DS3-L MICROINVERTERS (1)100A PV LOAD CENTER (1)60A KNIFE AC DISCONNECT MSP UPGRADE: NO MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: UNIRAC FLASHLOC FOR COMP SHINGLE ROOF RACKING TYPE: EVEREST CROSSRAIL- ROOF MOUNT RACKING HARDWARE EXISTING PV SYSTEM : DC SYSTEM SIZE:- 3.360kW AC SYSTEM SIZE:- 3.800kW COMBINED PV SYSTEM : DC SYSTEM SIZE:- 7.705kW AC SYSTEM SIZE:- 8.408kW Signed: 07/31/2023 THIS SYSTEM HAS BEEN REMOVED THIS SYSTEM IS STAYING AND IS IN THE CORRECT LOCATION Bldg# 101116729 Elec# 20181043 MSmith Issued 10/02/23 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 1218 S Mohawk Dr - 2018104310/3/2023 SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344T-21.1.PROJECT NOTES:1.2. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE 2022 CALIFORNIAELECTRICAL CODE (CEC) ARTICLE 690, ALL MANUFACTURER’S LISTING ANDINSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIEDBY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES.1.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED ANDPV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION1.4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE ISINTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH 2022 CEC690.41(B)1.5. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVEINVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED ANDLISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY 2022 CEC 690.4 PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY1.6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMPCOEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATEDACCORDING TO 2022 CEC 690.7.1.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, ANDSOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAICPOWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATIONPER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONSFROM LISTING OR LABELING [ 2022 CEC 110.3].1.8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDINGCODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALLPLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CECAND AHJ.1.9.SCOPE OF WORK:1.10. PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT.PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTINGONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THEEXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMSDETAILED IN THIS DOCUMENT.1.11.WORK INCLUDES:1.12. PV ROOF ATTACHMENTS - UNIRAC FLASHLOC FOR COMP SHINGLE ROOF1.13. PV RACKING SYSTEM INSTALLATION - EVEREST CROSSRAIL ROOF MOUNTRACKING HARDWARE1.14. PV MODULE AND INVERTER INSTALLATION - JA SOLAR JAM54S31-395/MR/(395W)MODULES / AP SYSTEM DS3-L MICROINVERTERS1.15. PV EQUIPMENT GROUNDING1.16. PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX1.17. PV LOAD CENTERS (IF INCLUDED)1.18. PV METERING/MONITORING (IF INCLUDED)1.19. PV DISCONNECTS1.20. PV GROUNDING ELECTRODE & BONDING TO (E) GEC1.21. PV FINAL COMMISSIONING1.22. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV1.23. SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE1.24.SITE NOTES:1.25. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.1.26. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THISSYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGEBATTERIES.1.27. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL, OR BUILDING ROOF VENTS.1.28. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION2022 CEC 110.26.1.29. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECTTHE BUILDING OR STRUCTURE.1.30.EQUIPMENT LOCATIONS:1.31. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2022 CEC110.26.1.32. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOREXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2022 CEC 690.31 (A),(C)AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C)1.33. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO 2022 CEC 690.34.1.34. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THEINVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT .1.35. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIEDPERSONNEL ACCORDING TO 2022 CEC APPLICABLE CODES.1.36. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOROUTDOOR USAGE WHEN APPROPRIATE.1.37.STRUCTURAL NOTES:1.38. RACKING SYSTEM1.39. PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANTINSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEENMODULES, AND RAILS MUST ALSO EXTEND1.40. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS.1.41. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'SSPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALEDPER LOCAL REQUIREMENTS.1.42. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED ANDSEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSEDCONTRACTOR.1.43. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THANTHE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.1.44. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.1.45.WIRING & CONDUIT NOTES:1.46. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIRPURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUMCODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.1.47. CONDUCTORS SIZED ACCORDING TO 2022 CEC 690.8, 2022 CEC 690.7.1.48. VOLTAGE DROP LIMITED TO 1.5%.1.49. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITHSUITABLE WIRING CLIPS.1.50. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASEPHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTIONNEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THEPHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [2022 CEC 110.151.51.GROUNDING NOTES:1.52. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIRPURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALLBE RATED FOR SUCH USE.1.53. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO 2022 CEC 690.43 ANDMINIMUM 2022 CEC TABLE 250.122.1.54. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURESCONSIDERED GROUNDED IN ACCORDING WITH 2022 CEC 250.134 AND 2022250.136(A).1.55. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TOCEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS.1.56. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS ASSHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THEAHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BEINSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THEMANUFACTURERS' INSTALLATION REQUIREMENTS.1.57. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCHTHAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDINGCONDUCTOR TO ANOTHER MODULE.1.58. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BECOLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [2022 CEC250.119]1.59. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 ANDCEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, ORINADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TOCEC 250, CEC 690.47 AND AHJ.1.60. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41 IN GENERALAND CEC 690.41 (A)(1) SPECIFICALLY.1.61.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:1.62. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THESWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARECONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THEUPPER TERMINALS).1.63. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH1.64. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 1 FT OF PVARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLEDCONDUCTORS ≤30V AND ≤240VA [CEC 690.12(B)]. LOCATION OF LABELACCORDING TO AHJ1.65. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8,690.9, AND 240.1.66. EQUIPMENT THAT IS LISTED, LABELED, OR BOTH SHALL BE INSTALLED ANDUSED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTINGOR LABELING. CEC 110.3(B).1.67. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUITPROTECTION ACCORDING TO CEC 690.11 AND UL1699B.1.68.ELECTRICAL INTERCONNECTION NOTES:1.69. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAYNOT EXCEED 120% OF THE BUSBAR RATING.1.70. WHEN THE SUM OF THE PV SOURCES EQUALS >100% OF THE BUSBARRATING, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITEEND OF THE BUS FROM THE UTILITY SOURCE OCPD.1.71. AT MULTIPLE PV OUTPUT COMBINER PANEL, THE TOTAL RATING OF ALLOVERCURRENT DEVICES SHALL NOT EXCEED THE AMPACITY OF THEBUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BEEXCLUDED.1.72. SUPPLY-SIDE TAP INTERCONNECTION SHOULD BE WITH SERVICE ENTRANCECONDUCTORS.1.73. BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT ISEXEMPT FROM ADDITIONAL FASTENING.Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023 07/31/2023 RE: Structural Certification for Installation of Residential Solar        RAUL GONZALEZ:1218 S MOHAWK DR, SANTA ANA, CA, 92704 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7‐16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 110 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E. Signed 07/31/2023 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the  PV system to existing roof framing.  From the field observation report, the roof is made of Composition shingle  roofing over roof plywood supported by 2X4 Trusses at 24 inches. The slope of the roof was approximated to be  19 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof  framing has been determined to be adequate to support the imposed loads without structural upgrades.  Contractor shall verify that existing framing is consistent with the described above before install. Should they  find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity  calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 1218 S Mohawk Dr - 2018104310/3/2023 Structural Letter for PV Installation Date: 07/31/2023 Job Address:1218 S MOHAWK DR SANTA ANA, CA, 92704 Job Name:RAUL GONZALEZ Job Number:230731RG Scope of Work Table of Content Sheet 2 Cover 3 Attachment Uplift checks 4 Roof Framing Check 5 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7‐16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 110 mph Exposure C References NDS for Wood Construction Sincerely, Signed 07/31/2023 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV  system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's  approved installation specifications.  projects@evengineersnet.com http://www.evengineersnet.com 1218 S Mohawk Dr - 2018104310/3/2023 Wind Load Cont. 110 mph ASCE 7‐16 Figure 26.5‐1B C 1.0 ASCE 7‐16 Sec 26.8.2 0.85 ASCE 7‐16 Table 26.10‐1 0.85 ASCE 7‐16 Table 26.6‐1 1.00 ASCE 7‐16 Table 26.9‐1 22.32 psf 19.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e) Zone(2r, 2n) Zone(3e) Zone(3r) Fig. 30‐3‐2 GCp=‐1.1 ‐2 ‐2 ‐2.4 Eq. 29.4‐7 P=qh(GCp)(γE)(γa)=‐29.47 ‐53.58 ‐53.58 ‐64.29 GCp=0.5 Figure 30.3‐2 P=qh(GCp)(γE)(γa)=7.37 Equation 29.4‐7 Rafter Attachments: 0.6D+0.6W (CD=1.6)  Connection Check Attachment max. spacing= 6 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A ‐ NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1,2e)6 16.5 176.8 171.1 Zone(2r, 2n)6 16.5 308.1 171.1 Zone(3e)6 16.5 308.1 171.1 Zone(3r)6 16.5 366.4 171.1 Conservative Max=366.4 < 760 CONNECTION IS OK Risk Category = KZ = Kd = Ke = 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw.  Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift  governs  γE= γa=  KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration projects@evengineersnet.com http://www.evengineersnet.com 1218 S Mohawk Dr - 2018104310/3/2023 Vertical Load Resisting System Design Roof Framing Trusses Snow Load Fully Exposed pg= 0 psf Ct =1.1 Ce =0.9 Is =1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT =24 in Dr =10psf 20 plf PvDL =3 psf 18 plf Load Case: DL+0.75(0.6W+S)   0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=45 plf Mdown=238 lb‐ft Mallowable = Sx x Fb' (wind)= 456 lb‐ft > 238 lb‐ft OK Load Case: DL+S   Ps+ Ppvcos(θ)+PDL=38 plf Mdown=203 lb‐ft Mallowable = Sx x Fb' (wind)= 456 lb‐ft > 203 lb‐ft OK Load Case: DL+0.6W   Pnet+ Ppvcos(θ)+PDL=46.8 plf Max Moment, Mu=250 lb‐ft Mallowable = Sx x Fb' (wind)= 634 lb‐ft > 250 lb‐ft OK Pv max Shear= 171.1 lbs Shear, Vu=wL/2+Pv Point Load =323 lbs Max Shear, Vu=wL/2+Pv Point Load =323 lb Member Capacity DF‐L No.2  2X4 CL CF Ci Cr KF φλ Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 3.5 in Width, b = 1.5 in Cross‐Sectonal Area, A = 5.25 in2 Moment of Inertia, Ixx =5.35938 in4 Section Modulus, Sxx =3.0625 in Allowable Moment, Mall = Fb'Sxx =396.2 lb‐ft DCR=Mu/Mall =0.52 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.51 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 1218 S Mohawk Dr - 2018104310/3/2023 Siesmic Loads Check Roof Dead Load 10 psf  % or Roof with Pv 23% Dpv and Racking 3 psf Average Total Dead Load 10.7 psf Increase in Dead Load 2.8%OK  Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and  therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans ‐ RAUL GONZALEZ. The analysis was according to applicable building codes, professional engineering and design  experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the  proposed solar panel installation referenced in the stamped plan set and were made according to generally  recognized structural analysis standards and procedures.  projects@evengineersnet.com http://www.evengineersnet.com 1218 S Mohawk Dr - 2018104310/3/2023 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1053344 Solgen Construction, LLC Cole Farmer Permits@CoreEnergyGroup.com 559-462-6009 1218 S Mohawk Dr, Santa Ana, CA 92704 08/01/2023 1218 S Mohawk Dr - 2018104310/3/2023 To whom it may concern, This letter serves to confirm I have chosen to have my system installed by Solgen Construction LLC. You have my express permission to move forward with the solar permit applied for by Solgen Construction LLC for my property at 815 S Van Ness Ave, Thank you, Santa Ana, CA 92704. Raul Gonzalez 1218 S Mohawk Dr, DocuSign Envelope ID: 42E9E932-C682-424B-82F6-4CDEC4B74105 8/1/2023 1218 S Mohawk Dr - 2018104310/3/2023 Certificate Of Completion Envelope Id: 42E9E932C682424B82F64CDEC4B74105 Status: Completed Subject: Complete with DocuSign: Raul Gonzalez - Homeowner Authorization Letter_1218 S Mohawk Dr.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Core Energy Group AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 727 Eagle Pass North Salt Lake, UT 84054 proposals@coreenergygroup.com IP Address: 71.41.39.59 Record Tracking Status: Original 8/1/2023 9:09:46 AM Holder: Core Energy Group proposals@coreenergygroup.com Location: DocuSign Signer Events Signature Timestamp Raul Gonzalez Rauling54@sbcglobal.net Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 76.32.192.144 Signed using mobile Sent: 8/1/2023 9:13:21 AM Viewed: 8/1/2023 2:18:24 PM Signed: 8/1/2023 2:18:40 PM Electronic Record and Signature Disclosure: Accepted: 8/1/2023 2:18:24 PM ID: 088c02c5-d20e-47e3-a89b-d50d8936ab56 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Core Permits permits@coreenergygroup.com Mr. Security Level: Email, Account Authentication (None) Sent: 8/1/2023 2:18:41 PM Viewed: 8/1/2023 2:35:38 PM Electronic Record and Signature Disclosure: Accepted: 7/31/2023 5:41:38 AM ID: eecd1ac8-7a80-4390-b345-ea48050a9cc2 Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 8/1/2023 9:13:21 AM Certified Delivered Security Checked 8/1/2023 2:18:24 PM Signing Complete Security Checked 8/1/2023 2:18:40 PM Completed Security Checked 8/1/2023 2:18:41 PM 1218 S Mohawk Dr - 2018104310/3/2023 Payment Events Status Timestamps Electronic Record and Signature Disclosure 1218 S Mohawk Dr - 2018104310/3/2023 ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Solgen Construction LLC (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 2/16/2023 3:39:07 PM Parties agreed to: Raul Gonzalez, Core Permits 1218 S Mohawk Dr - 2018104310/3/2023 Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Solgen Construction LLC: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: proposals@solgen.co To advise Solgen Construction LLC of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at proposals@solgen.co and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Solgen Construction LLC To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to proposals@solgen.co and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Solgen Construction LLC To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: 1218 S Mohawk Dr - 2018104310/3/2023 i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to proposals@solgen.co and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify Solgen Construction LLC as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Solgen Construction LLC during the course of your relationship with Solgen Construction LLC. 1218 S Mohawk Dr - 2018104310/3/2023