1422 W Marion Way - 101121871 & 20184663 - Plan
AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-1 PROJECT INFORMATION/SCOPE OF WORK VICINITY MAP SHEET INDEX APPLICABLE CODES PLAN SET LEGEND SUB SERVICE PANEL AC DISCONNECT DC DISCONNECT SOLAR COMBINER BOX INVERTER SUB AC DC SLC INV JUNCTION BOXJB ABBREVIATIONS EXTERIOR INTERIOR EXT INT NEW(N) EXISTING(E) ELECTRICAL METALLIC TUBINGEMT RIGID METALLIC CONDUITRMC VOLTAGE OPEN CIRCUITVOC VOLTAGE AT MAX. POWERVMP SHORT CIRCUIT CURRENTISC CURRENT AT MAX. POWERIMP AHJ NOTES PV MONITORINGM NOT TO SCALENTS MAIN SERVICE PANELMSP PROJECT INFORMATIONPV-1 PROJECT INFORMATION PV-1A SITE PLAN, HOUSE PHOTO PV-1B FIRE ACCESS PATHWAY PLAN PV-2 ROOF PLAN PV-2A ATTACHMENT DETAILS PV-2B BATTERY DETAILS PV-3 ELECTRICAL LINE DIAGRAM & ELECTRICAL CALCULATIONS PV-3A ELECTRICAL NOTES PV-4 & 4A REQUIRED SIGNAGE ENPHASE AC SOLAR PVENCOMBINER BOX PROJECT SITE FLEXIBLE METALLIC CONDUITFMC PERFORMANCE METER STORAGE BATTERYBAT PLP PROTECTED LOAD PANEL AUTHORITY HAVINGAHJ JURISDICTION RIGID GALVANIZED STEELRGS ENERGY STORAGEESS SYSTEM 14 X 400 W LONGL GUHHQ EQHUJ\ THFKQRORJ\ CR., LWG. LR5-54HABB-400M ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 14 X 290 W EQSKDVH EQHUJ\ IQ8PLUS-72-2-US (SI1-JUN20) (240V) SYSTEM SIZE:5.600 NW DC STC, 5.083 NW CEC-AC ARRAY AREA:294 SF PANEL UPGRADE:225 A AHJ:CITY OF SANTA ANA APN:001-055-05 ROBERTO DOMINGUEZ 1422 MARION WAY WEST SANTA ANA, CA 92706 INSTALLATION OF NEW SOLAR PV & ESS SYSTEM: ALL WORK TO COMPLY WITH THE FOLLOWING CODES: 2022 CA BUILDING CODE 2022 CA RESIDENTIAL CODE 2022 CA MECHANICAL CODE 2022 CA ELECTRICAL CODE 2022 CA GREEN CODE 2022 CA PLUMBING CODE 2022 CA ENERGY CODE 2022 CA FIRE CODE LOCAL JURISDICTION AMENDMENTS GAT TESLA BACKUP GATEWAY 2 1 X TESLA BACKUP GATEWAY 2 LATITUDE 33.767250 - LONGITUDE -117.887090 OCCUPANCY: R-3 CONSTRUCTION TYPE: VB UNSPRINKLERED 1 X TESLA POWERWALL 3 BATTERY PER SECTION R314 AND R315 OF CRC 2022, IT'S REQUIRED THAT SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLING FOR A PERMIT WITH REPAIRS OR ADDITIONS EXCEEDING 1,000. ALL NEW UTILITY CONNECTIONS ARE REQUIRED TO BE INSTALLED BELOW GRADE BY SANTA ANA MUNICOPAL CODE 41-626(B). THERE IS A STANDING EXCEPTION FOR EXISTING ONE AND TWO FAMILY DWELLINGS. THIS EXCEPTION APPLIES ONLY WHEN THE NEW ELECTRICAL SERVICE IS DESIGNATED TO BE FED FROM BELOW GRADE AS WELL AS OVERHEAD. ONLY LISTED COMBINATION OVERHEAD AND UNDERGROUND FEED SERVICE BOXES MAY BE USED TO CONNECT TO AN OVERHEAD UTILITY DROP. THIS EXCEPTION TO AN UNDERGROUND FED SERVICE APPLIES ONLY TO EXISTING SINGLE FAMILY AND TWO FAMILY RESIDENCES. 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.SCALE: 1":15'-0" N SCALE: N.T.S.HOUSE PHOTOSITE PLAN PV-1ASITE PLAN, HOUSE PHOTOARRAY LOCATION BRANCH CIRCUIT # OF PANELS TILT, AZIMUTH 17 5°, 180° 27 5°, 180° dKd>ηK& WE>^ϭϰ 4 2 3 (E) ONE-STORY HOUSE (N) SOLAR PV ARRAY PER TABLE BELOW FIRE ACCESS POINT 1 2 3 SITE PLAN LEGEND (E) DRIVEWAY 4 5 6 1 (N) PV & ESS EQUIPMENT TOTAL ROOF AREA:2,090 SF TOTAL MODULE AREA: 294 SF TOTAL ROOF COVERAGE:14.1 % (E) DETACHED GARAGE SEE PV1B FOR FIRE ACCESS PATHWAYS PV-2 FOR ROOFTOP EQUIPMENT CALLOUTS AND ROOF AND ARRAY DIMENSIONS. 6 MICROINVERTERWITH BUILT INRAPID SHUTDOWNLOCATED AT EACHMODULE MSPAC BAT ACPLPGAT5 5 33'-3"11'-11" 5'-0"17'-8"63'-8"101'-4"101'-4"63'-8" B1 B1 B1B1 B1 B1 B2 B2B2 B2B2 B2B2 B1 MARION WAY WEST PL PLPL PL EN A 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.SCALE: 1":10'-0"ROOF PLAN N ARRAY & ROOF INFO MODULE TYPE, DIMENSIONS & WEIGHT PV-2ROOF PLAN1 1 LAYER OF ROLLED COMP 2x4 RAFTERS @ 16" o.c 180 5 635 180 5 294 14.1% 14 64 Roof Plane Roof Type: Roof Framing: Roof Azimuth (deg): Roof Slope (deg): Roof Area (sf): Array Azimuth (deg): Array Tilt (deg): Array Area (sf): % Coverage of Roof # of Panels Attachment spacing (in): PANEL TYPE: LR5-54HABB-400M PANEL WEIGHT: 49.6 LB PANEL DIMENSIONS: 67.8 IN. X 44.7 IN. PANEL AREA:21.00 SF UNIT WEIGHT OF PANELS:49.6LB/21SF = 2.36 PSF RACKING 0.19 PSF AREA PER ATTACHMENT: 5.33'X2.83' = 15.1 SF WEIGHT PER ATTACHMENT: 15.1SFX2.55PSF = 40.8 LB FIRE ACCESS POINT1 2 3 ROOF PLAN LEGEND 1 2 4 (N) CONDUIT ROUTE MICROINVERTERWITH BUILT INRAPID SHUTDOWNLOCATED AT EACHMODULE (E) INTERIOR RAFTER SUPPORT 5 6 3 ACCESSES IDENTIFIED ARE AT STRONG POINTS OF ROOF WHICH DO NOT HAVE OPENINGS BELOW LADDER ACCESSES. PER CRC R331.4.1. (E) RISER (E) EXTERIOR WALL (E) PLUMBING VENT 4 5 7 7 (E) CHIMNEY 8 (E) AC UNIT ALL ARRAY AND ROOF INFORMATION IS SHOWN TO THE RIGHT INCLUDING FRAMING AND ATTACHMENT SPACING. CONDUIT SHALL BE EMT CONDUIT (EXTERIOR) OR EMT OR FMC AS AHJ ALLOWS (INTERIOR), CONTRACTOR TO RUN CONDUIT ON ROOF AND UNDER EAVES OR WITHIN ATTIC. CONDUIT RUN TO BE DETERMINED AT THE TIME OF INSTALL. ANY EXPOSED CONDUIT SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE. 6 8 1'-6"6'-11"6'-11"1'-8"2'-5"10'-0"MSPEN ACPLPGATAC JB R1 SLOPE5'-4"4'-0"A BAT 1422 W Marion Way1/24/2025 AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.SCALE: 1":15'-0" N FIRE ACCESS PATHWAYS & RIDGE SETBACK PLAN PV-1BPATHWAY PLANTOTAL ROOF AREA:2,090 SF TOTAL MODULE AREA:294 SF TOTAL ROOF COVERAGE:14.1 FIRE ACCESS R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCHWIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A MINIMUM 36-INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. R324.6.2 SETBACK AT RIDGE: FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN AN 18-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN A 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING: PANELS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. LEGEND PATHWAY ON STREET OR DRIVEWAY1 SIDE OF THE ROOF FIRE ACCESS POINT2 18" SETBACK TO HIP/VALLEY 1 36" FIRE ACCESS PATHWAYS 18" SETBACK ON BOTH SIDES OF RIDGE PER R324.6.2 2 3 (E) ROOF SLOPE LESS THAN 2:123 R324.6.2 RIDGE SETBACK EXCEPTION: 2:12 (9.5) OR LESS ROOF SLOPES 1422 W Marion Way1/24/2025 UNIRAC STRONGHOLD BUTYL UNIRAC NXT UMOUNT RAIL 5/16" STAINLESS STEEL LAG BOLTMIN. 1.5" PENETRATION SEALED W/ BUTYL SEALANT (E) ROOF FRAMING, SEE ROOF INFO MATCH (E) ROOF SLOPEPV MODULES ATTACHMENTS 0' -4" UNIRAC STRONGHOLD CLAMP AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.EXISTING 2"X4" RAFTERS @ 16" O.C. (E) INTERIOR WALL 6'-11"6'-11" 2"x4" PURLIN NEW 225A /200A MAIN BREAKER 120/240V 1ɸ 3W OVERHEAD MAIN SERVICE PANEL & METER SOUTH WALL OUTSIDE NEW 30A PV DISCONNECT NEW TESLA POWERWALL 3 INVERTER / BATTERY WEST WALL OUTSIDE Gas EXISTING GATE NEW TESLA GATEWAY 2 NEW PROTECTED LOAD PANEL EXISTING WINDOW NEW 60A BATTERY DISCONNECT EXISTING WINDOW NEW ENPHASE AC COMBINER BOX TESLA POWERWALL 3 BATTERY1/4" LAG SCREWS 2 PER END (E) 2X4 WALL STUD @ 16" o.c. PV-2AATTACHMENT DETAILSSCALE: 1/2" = 1'-0"ATTACHMENT DETAIL SCALE: 3/8" = 1'-0"EQUIPMENT ELEVATION DETAIL SCALE: 1/2" = 1'-0"RAFTER SECTION DETAIL 3'-0"1'-0"BATTERY MOUNT DETAIL SCALE: N.T.S A 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.SINGLE LINE DIAGRAMSCALE: N.T.S.ELECTRICAL SINGLE LINE DIAGRAM PV-3 STRINGS CONNECTED IN PARALLEL SEE PV-3A FOR ELECTRICAL NOTES >KtDEdDWWZ ^,Z,EKK< D&ZsK>d'dDW K&&//Ed;ŽͿ sK>d'>KtdDW͘ KZZ͘;ŽͿ ,/',D/EddDW ;ŽͿ KEh/d,/',d ;ŝŶͿ ZKK&dKWdDWWZ dĂďůĞϯϭϬ͘ϭϱ;Ϳ;ϯͿΞ;ŽͿ :h^ddDW dDW KZZd/KE ZKK&Ϯ -0.265 1.06 ϯϭ KsϳͬϴΗD/E͘Ϭϯϭ͘ϵϲ t>>Ϯ ϯϭ EͬϬϯϭ͘ϵϲ 5.600kW DC STC, 5.083 kW CEC-AC SOLAR ARRAY 14 LONGi Green Energy Technology Co., Ltd. 400W MODULES TOTAL TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1PH, 120/240V, 3W (N) 225A MAIN SERVICE PANEL (N) MAIN SERVICE DISCONNECT 240V, 200A NOT CENTER FED PANEL DECAL LONGi Green Energy Technology Co., Ltd. LR5-54HABB-400M 400W Vmp= 30.94V Voc= 37.05V Isc= 13.72A Imp= 12.93A CEC PTC POWER=374.3W Enphase Energy IQ8PLUS-72-2-US (SI1-JUN20) (240V) INVERTER MAX DC VOLTAGE: 60V DC VOLTAGE INPUT RANGE: 25-58V @240V PEAK POWER TRACKING VOLTAGE: 29-45V @240V AC NOMINAL VOLTAGE/RANGE: 211-264V @240V MAX AC OUTPUT CURRENT: 1.21A CEC WEIGHTED EFFICIENCY: 97% @240V BRANCH CIRCUIT # OF PANELS TILT, AZIMUTH 17 5°, 180° 27 5°, 180° dKd>ηK& WE>^ϭϰ 600 V, NEMA 3R W/ EUROSTRIP OR POLARIS IT CONNECTORS JUNCTION BOXA ELECTRICAL EQUIPMENT CALLOUTS B Ϭ͘ϮϵŬt/EsZdZhE'ZKhE EW,^EZ'z/YϴW>h^ͲϳϮͲϮͲh^ ;^/ϭͲ:hEϮϬͿ;ϮϰϬsͿ;ϮϰϬsͿ/EsZdZϮϰϬs͕ ϭ͘ϮϭEDϯZ͕h>>/^d͕;t/d, /Ed'Zd/^KEEdͿ t/Z d'η KEh/d t/ZYdz ;ZZz hZZEdͿ t/Z 'h' ;t'Ϳ t/ZdzW t/Z >E'd, ;&dͿ dDW Zd/E'͗ t/Z >Kd/KE :h^d t/ZdDW t/Z DW dDW KZZd/KEWZ d> ϯϭϬ͘ϭϱ;Ϳ;ϮͿ;ĂͿ͗ KEh/d&/>>WZ dĂďůĞ ϯϭϬ͘ϭϱ;Ϳ;ϯͿ;ĂͿ͗ t/Z KW͗ dZD/E> ϳϱŽZd/E'/EsZdZYdz͗KhdWhd hZZEd ϲϵϬ͘ϴ;Ϳ ^dZ/E' DW^ 'ZKhE ^/ 'ZKhE dzWKW,< ϭEKE Ϯ ϭϮ dZhE< >ϭϱ ϵϬΣ ZKK& ϯϭ ϯϬ y Ϭ͘ϵϲ y ϭ с Ϯϴ͘ϴ Ϯϱ ϳ y ϭ͘Ϯϭ y ϭ͘Ϯϱ с ϭϬ͘ϱϵ ηϲ ^ EKE Ϯ ϯͬϰΗDd ϰϭϬd,tEͲϮ ϳϬ ϵϬΣ ZKK& ϯϭ ϰϬ y Ϭ͘ϵϲ y Ϭ͘ϴ с ϯϬ͘ϳϮ ϯϱ ϳ y ϭ͘Ϯϭ y ϭ͘Ϯϱ с ϭϬ͘ϱϵ ηϴ d,tEͲϮ ϮϬϮW ϳyϭ͘Ϯϭ yϭ͘Ϯϱ с ϭϬ͘ϱϵ ηϴ d,tEͲϮ ϮϬϮW ϮĂ ϯͬϰΗDd ϯϲd,tEͲϮ ϭϬ ϵϬΣ t>> ϯϭ ϳϱ y Ϭ͘ϵϲ y ϭсϳϮϲϱ ϭ y ϰϴ y ϭ͘Ϯϱ с ϲϬ ηϴ d,tEͲϮ ϲϬϮW ϯ ϯͬϰΗDd ϯϭϬd,tEͲϮ ϱ ϵϬΣ t>> ϯϭ ϰϬ y Ϭ͘ϵϲ y ϭсϯϴ͘ϰ ϯϱ ϭϰ y ϭ͘Ϯϭ yϭ͘Ϯϱ с Ϯϭ͘ϭϴ ηϴ d,tEͲϮ ϮϱϮW ϰ ϭϭͬϰΗDd ϯϯd,tEͲϮϱ ϵϬΣ t>> ϯϭ ϭϭϱ y Ϭ͘ϵϲ y ϭ с ϭϭϬ͘ϰ ϭϬϬ ;ϮϮyϭ͘ϮϭͿн;ϰϴͿ y ϭ͘Ϯϱ с ϴϭ͘ϭϴ ηϴ d,tEͲϮ ϭϬϬϮW C AC DISCONNECT 240 VAC, 60A NEMA 3R, UL LISTED ENPHASE COMBINER BOX, 125A ENPHASE IQ COMBINER 4 X2-IQ-AM1-240-4 240V, NEMA 3R, UL 1741 2-POLE 100A GATEWAY BREAKER,BOND TO EXISTING UFER DyWssK>d'ΘhZZEd>^͗ RECORD LOW TEMP (˚C): (PER ASHRAE HANDBOOK)Ϯ TEMP COEFFICIENT (Voc) PER MANUFACTURER:ͲϬ͘Ϯϲϱйͬ VOLTAGE CORRECTION:ϭ͘Ϭϲ DyWs^z^dDsK>d';WZϮϬϮϮϲϵϬ͘ϳͿ͗ ;sĐŽƌƌĞĐƚŝŽŶΎsŽĐͿ ;ϭ͘ϬϲΎϯϳ͘ϬϱͿсϯϵ͘ϯs DyWsKEd/EhKh^hZZEdWZϮϬϮϮ ϲϵϬ͘ϴ;Ϳ;ϭͿ͗ ϭ͘Ϯϱy/ƐĐyη^dZ/E'^ ϭ͘ϮϱΎϭϯ͘ϳϮсϭϳ͘ϭϱ CT CT CT CT CT MONITOR AUTOMATIC TRANSFER SWITCH CTRL H + - CTRL F BATTERY BREAKER 240 V, A, 2P60 PV BREAKER 240 V, A, 2P25 G C D E PV BREAKER 240 V, A, 2P20 PV BREAKER 240 V, A, 2P20 MONITOR BREAKER 240 V, 15A, 2P JB A BRANCH CIRCUIT BB 1 MICROINVERTER PER PANEL2 BRANCH CIRCUIT BB 1 MICROINVERTER PER PANEL1 INTERCONNECTION METHOD PER 705.12(B)(3)(3): 100A GATEWAY BREAKER 50A AC UNIT BREAKER 150A </= 225A MAIN & BUS RATING, OK MODULES ARE CONNECTED IN PARALLEL, NOT IN SERIES. EACH MICROINVERTER IS EQUIPPED WITH RAPID SHUTDOWN CAPABILITIES. F TESLA POWERWALL 3 BATTERY AC OUTPUT:48A H TESLA BACKUP GATEWAY 2, NEMA 3R, WITH AUTOMATIC TRANSFER SWITCH G 125A PROTECTED LOAD PANEL WITH 100A MAIN BREAKER D BATTERY DISCONNECT 240 VAC, 60A NEMA 3R, UL LISTED E BOND #4 AWG TO UNDERGROUND WATER SERVICE LESS THAN 5' FROM WHERE IT ENTERS THE BUILDING 100A MAIN BREAKER NOTE: (E) BRANCH BREAKER RELOCATED FROM MAIN. IF EXTENDED BEYOND 6', 15A & 20A CIRCUITS SHALL BE COMBINATION-TYPE AFCI PROTECTED IN COMPLIANCE WITH NEC 210.12(B) A (N) 26 - #12 THWN-2, 6 - #10 THWN-2, 15 - #10 GND IN 1 1/2" EMT, L < 24" 1422 W Marion Way1/24/2025 AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-3AELECTRICAL NOTESELECTRICAL NOTES PER 2022 CEC, 690.64 (B)(7): LOCATE INVERTER OUTPUT AS FAR AS POSSIBLE FROM NORMAL POWER SUPPLY AT SERVICE PANEL. RELOCATION OF EXISTING CIRCUITS MAY BE NEEDED. DO NOT CHANGE PHASING OF MULTI-WIRE CIRCUITS. PERMANENT SIGNAGE AT PV SUPPLY CIRCUIT BREAKERS MUST SAY: WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. SIGNAGE TO BE LOCATED ADJACENT TO BACKFED BREAKER. ADDITIONAL AHJ REQUIRED ELECTRICAL NOTES 1. PV ARRAYS ARE PER SINGLE LINE.. 2. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 3. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER CEC 250.58. 4. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. 5. CONNECTORS SHALL BE POLARIS OR EUROSTRIP IT CONNECTORS. 6. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHED CUT SHEET. 7. AC DISCONNECT SHALL BE PER SINGLE LINE. 8. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO CEC 690. 9. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. 10. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5 11. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 12. ALL WORK TO COMPLY WITH 2022 CALIFORNIA ELECTRIC CODE, 2022 CALIFORNIA BUILDING CODE 13. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. 14. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. 15. CONDUCTORS ON ROOF ARE TO BE A MINIMUM OF 7/8" OFF OF THE ROOF SURFACE. 16.GEC TO BE CONNECTED TO EXISTING UFER. IF UFER IS NOT PRESENT THEN A NEW GROUND ROD WILL BE ADDED FOR GROUNDNG PURPOSES. 17. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS WHITE. 18. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE SMALLER THAN 14 AWG. 19. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. RACKING & MODULES ARE CONNECTED TO THE EGC W/ UNIRAC NXT UMOUNT LUG. MODULES ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS DC SIDE OF ARRAY IS UNGROUNDED AND THEREFORE GEC IS NOT REQUIRED. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES PER CEC 690.9 (A) GROUNDING: UNIRAC NXT UMOUNT LUG UL LISTED 2703 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.PV-3BPLP SCHEDULE PROTECTED PANEL LOAD CALCULATIONSPROTECTED PANEL LOAD CALCULATIONS ISSUEDFOR:PE24-1937PV-3BPLP SCHEDUAB1/9/2025-ERMITDATE:11/26/2024R14SA(7LE Solar PhotovROBERTO DOMINGUE422 MARION WAY WESTANTA ANA, CA 92706714)-742-4256voltaic SystemEZ98RivPhCSX_GIN880 Indiana Avenue, Suite 2verside, CA 92503hone:(866) 464-8968SLB #997054 (B,C-10,C-46,C-39)_______________________UYOU CONSTRUCTION,NC.)A 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.PV-4REQUIRED SIGNAGEFRONT OF HOME CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: SOLAR ARRAY MAP PLACARD ON FACE OF THE MAIN SERVICE PANEL PER CEC 705.10: MSP6 MARION WAY WEST 1422 MARION WAY WESTSANTA ANA, CA 92706 YOU ARE HERE ON THE FACE OF THE MAIN SERVICE DISCONNECT PER CEC 690.13(B): PV SYSTEM DISCONNECT THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8" HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. ON FACE OF THE SERVICE METER PANEL: SIGNAGE AT MAIN SERVICE PANEL: MSP1 MSP2 MSP5 MSP3 MAXIMUM AC OPERATING CURRENT = 16.94A MAXIMUM AC OPERATING VOLTAGE = 240V RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM ON FACE OF THE SERVICE METER PANEL PER CEC 690.56 (C)(1)(a): SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 3/8" IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16" IN BLACK ON WHITE BACKGROUND. ON RAPID SHUTDOWN SWITCH LOCATED ON OR WITHIN 3' FROM SWITCH, IN 38" LETTERS IN WHITE ON RED BACKGROUND ON A REFLECTIVE LABEL PER CEC 690.56 (C)(3): MSP4 WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LOCATED AT BACKFED BREAKER PER CEC 705.12(B)(2)(3)(b): MSP7 ON FACE OF THE SERVICE METER PANEL PER CEC 705.10: CAUTION MULTIPLE SOURCES OF POWER SERVICE POINT & UTILITY METERING BATTERY DISCONNECT MSP8 WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR LOCATED AT MAIN SERVICE PANEL PER CEC 705.12(B)(3)(3):PV DISCONNECT PROTECTED LOAD PANEL GATEWAY PV COMBINER BOX STORAGE BATTERY A 1422 W Marion Way1/24/2025 AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-4AREQUIRED SIGNAGESIGNAGE AT COMBINER BOX/ SUBPANEL: E1 E2 ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): PV SYSTEM DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): ON FACE OF THE SUB PANEL: E3 E4 PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS ON FACE OF THE PV COMBINER PANELBOARD: MAXIMUM AC OPERATING CURRENT = 16.94A MAXIMUM AC OPERATING VOLTAGE = 240V SIGNAGE AT BATTERY STORAGE: ENERGY STORAGE SYSTEM DISCONNECT: NOMINAL ESS AC VOLTAGE =240 V MAXIMUM ESS DC VOLTAGE = F1 ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): 550 V F2 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): F3 ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): WARNING ENERGY STORAGE SYSTEM F4 BATTERY DISCONNECTING MEANS ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): SIGNAGE AT AC DISCONNECT: C1 C2 ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): PV SYSTEM DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): 1422 W Marion Way1/24/2025 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018)The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.IQ Combiner 4/4CTo learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Gateway for communication and control• Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C• Includes solar shield to match Enphase IQ Battery EIWXLIXMGWERHHIƥIGXLIEX• Supports Wi-Fi, Ethernet, or cellular connectivity• Optional AC receptacle available for PLC bridge• Provides production metering and consumption monitoringSimple• Mounts on single stud with centered brackets• Supports bottom, back and side conduit entry• Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included)• 80A total PV or storage branch circuitsReliableŵ (YVEFPI2680GIVXMƤIH2)1%X]TI6IRGPSWYVI• Five-year limited warranty• Two years labor reimbursement program coverage included for both the IQ Combiner SKU's•UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with -)))907&rd Ed.)X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018)Q-AM1-240-4C QAM12404C(IEEE 1547 2M1-240-4 2018)2018)-5''(7)297© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change.MODEL NUMBERIQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018)IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to HIƥIGXLIEXIQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018)IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the -5&EXXIV]ERH-57]WXIQ'SRXVSPPIVERHXSHIƥIGXLIEXACCESSORIES AND REPLACEMENT PARTS(not included, order separately)Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8)Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year AT&T data planCircuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B7YTTSVXW)EXSR&6&6&6&6&6&6ERH&6GMVGYMXFVIEOIVW Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit supportXA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C<%409+Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01)X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screwsConsumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP)A pair of 200A split core current transformersELECTRICAL SPECIFICATIONSRating Continuous dutySystem voltage 120/240VAC, 60 HzEaton BR series busbar rating 125AMax. continuous current rating 65AMax. continuous current rating (input from PV/storage) 64AMax. fuse/circuit rating (output)%Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. total branch circuit breaker rating (input)%SJHMWXVMFYXIHKIRIVEXMSR%[MXL-5+EXI[E]FVIEOIVMRGPYHIHIQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton includedProduction metering CT 200A solid core pre-installed and wired to IQ GatewayMECHANICAL DATADimensions (WxHxD)GQ\GQ\GQMR\MR\MR ,IMKLXMWGQMR [MXLQSYRXMRKFVEGOIXWWeight 7.5 kg (16.5 lbs)Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF)Cooling Natural convection, plus heat shieldEnclosure environmental rating3YXHSSV2680GIVXMƤIH2)1%X]TI6TSP]GEVFSREXIGSRWXVYGXMSRWire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors• 60A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductors• Always follow local code requirements for conductor sizing.Altitude9TXSQIXIVWJIIX INTERNET CONNECTION OPTIONSIntegrated Wi-Fi IEEE 802.11b/g/nCellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations.Ethernet3TXMSREP-)))'EX)SV'EX 984)XLIVRIXGEFPIRSXMRGPYHIH COMPLIANCECompliance, IQ Combiner CA Rule 21 (UL 1741-SA)-)))907&rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)'%2'7%'2S8MXPI'*64EVX'PEWW&-')7Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Consumption metering: accuracy class 2.5Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1IQ Combiner 4/4C-5''(7)2971422 W MarionWay1/24/2025 IQ8 and IQ8+ MicroinvertersOur newest IQ8 Microinverters are the industry’s first grid-forming microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesGrid-forming• Complies with the latest advanced grid support• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) requirements© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change.IQ8SP-DS-0002-01-EN-US-2021-10-19DATA SHEET(1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8 and IQ8+ MicroinvertersINPUT DATA (DC) IQ8-60-2-USIQ8PLUS-72-2-USCommonly used module pairings1W235 – 350 235 – 440Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cellMPPT voltage rangeV27 – 37 29 – 45Operating rangeV25 – 48 25 – 58Min/max start voltageV30 / 48 30 / 58Max input DC voltageV50 60Max DC current2 [module Isc]A15Overvoltage class DC portIIDC port backfeed currentmA0PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ8-60-2-USIQ8PLUS-72-2-USPeak output powerVA245 300Max continuous output powerVA240 290Nominal (L-L) voltage/range3V240 / 211 – 264Max continuous output currentA1.0 1.21Nominal frequencyHz60Extended frequency rangeHz50 – 68Max units per 20 A (L-L) branch circuit416 13Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed currentmA30Power factor setting1.0Grid-tied power factor (adjustable) 0.85 leading – 0.85 laggingPeak efficiency%97.5 97.6CEC weighted efficiency%97 97Night-time power consumptionmW60MECHANICAL DATAAmbient temperature range -40ºC to +60ºC (-40ºF to +140ºF)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (HxWxD) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesAcoustic noise at 1 m<60 dBAPollution degreePD3Enclosure Class II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure rating NEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8SP-DS-0002-01-EN-US-2021-10-191422 W MarionWay1/24/2025 1422 W MarionWay1/24/2025 1422 W MarionWay1/24/2025 TESLA.COM/ENERGYBackup Gateway 2POWERWALL660411149The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONSOperating Temperature–20°C to 50°C (–4°F to 122°F)Operating Humidity (RH)Up to 100%, condensingMaximum Elevation3000 m (9843 ft) EnvironmentIndoor and outdoor ratedEnclosure TypeNEMA 3RPERFORMANCE SPECIFICATIONSAC Voltage (Nominal)120/240VFeed-In TypeSplit PhaseGrid Frequency60 HzCurrent Rating200 AMaximum Input Short Circuit Current10 kA1Overcurrent Protection Device100-200A; Service Entrance Rated1Overvoltage CategoryCategory IVAC MeterRevenue accurate (+/– 0.2 %)Primary ConnectivityEthernet, Wi-FiSecondary ConnectivityCellular (3G, LTE/4G)2User InterfaceTesla AppOperating ModesSupport for solar self-consumption, time-based control, and backupBackup TransitionAutomatic disconnect for seamless backupModularitySupports up to 10 AC-coupled PowerwallsOptional Internal Panelboard200A 6-space / 12 circuit Eaton BR Circuit BreakersWarranty10 yearsCOMPLIANCE INFORMATIONCertificationsUL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205EmissionsFCC Part 15, ICES 003NA 2020-05-231 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes.2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength.MECHANICAL SPECIFICATIONSDimensions660 mm x 411 mm x 149 mm(26 in x 16 in x 6 in)Weight20.4 kg (45 lb)Mounting optionsWall mount, Semi-flush mount1422 W MarionWay1/24/2025 32023Powerwall 3 Datasheet Mechanical Specifications Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in) Weight 130 kg (287 lb) Mounting Options Floor or wall mount Powerwall 3 Technical Specifications Environmental Specifications Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IPX7 (Battery & Power Electronics) IPX5 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m <50 db(A) typical <62 db(A) maximum Compliance Information Certifications UL 1642, UL 1699B, UL 1741ȑȆȍȊȆˏ, UL 1741 SA, UL 1741 SB, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 1105 mm 193 mm m 42023Powerwall 3 Datasheet Electrical Specifications Model MCI-1 MCI-2 Nominal Input DC Current Rating (IMP)12 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Specifications Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X / IP65 NEMA 4X / IP65 RSD Module Performance Maximum Number of Devices per String 55 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Specifications Electrical Connections MC4 Connector MC4 Connector Housing Plastic Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip UL 3741 PV Hazard Control (and PVRSA) Compatibility The following categories of solar module meet the UL 3741 PVHCS listing when installed with Powerwall 3 and Solar Shutdown Devices. Tesla Solar Roof PV Hazard Control System: BIPV compliance document Tesla or Hanwha (Q.Peak Duo BLK or BLK-G6+) Modules certified for use with ZEP racking PV Hazard Control System: ZS PVHCS compliance document Other module and racking combinations PV Hazard Control System: Generic PV Array compliance document Compliance Information Certifications UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 7 Maximum System Voltage is limited by Powerwall to 600 V DC. 1422 W Marion Way1/24/2025 Powerwall 3Power Everything2023—Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 150 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production, fast and efficient installations, easy system expansion, and simple connection to any electrical service. 22023Powerwall 3 DatasheetSolar Technical SpecificationsMaximum Solar STC Input20 kWWithstand Voltage600 V DCPV DC Input Voltage Range60 — 550 V DCPV DC MPPT Voltage Range150 — 480 V DCMPPTs6Maximum Current per MPPT (Imp)13 A 5Maximum Short Circuit Current per MPPT (Isc)15 A 5Powerwall 3 Technical Specifications1 Typical solar shifting use case.2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power.3 Tested using CEC weighted efficiency methodology.4 Cellular connectivity subject to network service coverage and signal strength.5 Where the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A ISC.Battery Technical SpecificationsNominal Battery Energy13.5 kWh AC 2Maximum Continuous Discharge Power11.5 kWACMaximum Continuous Charge Power5 kW ACOutput Power Factor Rating0 - 1 (Grid Code configurable)Maximum Continuous Current48 ALoad Start Capability (1 s)150 A LRAPower ScalabilityUp to 4 Powerwall 3 units supportedSystem Technical SpecificationsModel Number1707000-xx-yNominal Grid Voltage120/240 V AC Grid ConfigurationSplit phaseGrid Frequency60 HzOvercurrent Protection DeviceConfigurable up to 60 ASolar to Battery to Grid Round Trip Efficiency89% 1,2Solar to Grid Efficiency97% 3Supported Islanding DevicesBackup Gateway 2, Backup SwitchConnectivityWi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4)Hardware InterfaceDry contact relay, Rapid Shutdown (RSD) certified switch and 2-pin connector, RS-485 for metersAC MeteringRevenue Grade (+/- 0.5%)ProtectionsIntegrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI), PV Rapid Shutdown (RSD) using Tesla Mid-Circuit InterruptersCustomer InterfaceTesla Mobile AppWarranty10 years1422 W MarionWay1/24/2025 Roberto Dominguez 1422 Marion Way West Santa Ana, CA 92706 12/03/2024 Building and Safety Department City of Santa Ana 20 Civic Center Plaza Santa Ana, CA 92701 Subject: Authorization for Guyou Construction to install PV System Dear Sir/Madam, I, Roberto Dominguez, the homeowner of the property located at 1422 Marion Way West, Santa Ana, CA 92706, hereby authorize Guyou Construction Inc to act as my agent in all matters related to the submission of permit applications to start the installation of a PV system on my property. Please accept and process any applications, plans, and documents they submit on my behalf in connection with the work to be carried out at this location. Thank you for your attention to this matter. Sincerely, Roberto Dominguez fi.tv'A Roberto Dominguez (Dec 6, 2024 08:47 PST) 12/11/2024 1422 W Marion Way1/24/2025 (G) GUVOU CONSTRUCTION, INC. 09/06/2024 To whom it may concern, This letter is to authorize the following to pull permits and business licenses on behalf of Guyou Construction Inc. CSLB license 997054 (8, C-10, C-39, C-46) valid through 9.6.2025 •Mario Baca •David Vitela •Desiree Luna •Jacob Muniz •Francine Garcia •Jenifer Sandoval •Raul Alarcon-1-iernandez •Marlon Viruete •Mauricio Corrales •Nico Matas •Keith Greetis •Arthur Honore •Hector Avina Marcus Gayou CEO MELISSA RODRIGUEZ COMM. #2389197 z Not&ry Public • C,llfomll s Rrverside County - M Comm. Ex ttes Jan. 3, 2026 A notary public or other officer con1pleting this cem cate verifies only the idenmy of the ,nd,vidual who signed the document to which this cert:hcate" attached, and 110t the tNthfulneu, accurac . or valid1t of hat document. S11tt_pf C:.llfornla, County ot_.....,..._ ____ .......,.__. Subscrlb d and sworn to (or affirmed) efore me •.• on 9880 Indiana Ave Ste 2 Riverside, CA 92503 I1.866.GO.GUYOU I info@guyouconstruction.com CSLB #997054 -B. C-10, C-39, C-46 1422 W Marion Way1/24/2025 Owner: Robert Dominguez Address: 1422 Marion Way West, Santa Ana, CA 92706 Sheet Item 1-2 Wind parameters 3-4 Seismic parameters and determination of Fp 5 design loads, roof member check, wind uplift check, deflection 6 attachment check, rail span check 7 lateral check Project Number: GUC-3004 Date: BASIS FOR DESIGN CODE:2022 California Building Code ASCE 7-16 LIVE LOADS ROOF 20.0 psf SNOW 0.0 psf CALCULATIONS FOR SOLAR PHOTOVOLTAIC PANELS: INDEX TO CALCULATIONS Engineering Calculations Performed By: Doug Engineering 5 Via Belmonte, Rancho Santa Margarita, CA 92688 949-285-5104 Engineering Calculations For: Guyou Construction, Inc. 9880 Indiana Avenue, Suite 2, Riverside, CA 92503 (866) 464-8968 11/26/2024 1422 W Marion Way1/24/2025 29.4.3 Rooftop Solar Panels for Buildings of All Heights with Flat Roofs or Gable or Hip Roofs with Slopes Less Than 7°. h = 15 ft mean roof height above ground, in ft h1 =1 ft Solar Panel Height above roof at low edge, in ft h2 =1.5 ft Solar Panel Height above roof at raised edge, in ft hpt =0 ft Mean parapet height above adjacent roof surface, in ft A = 5.22 sf Effective Wind area for structural element being designed, in ft2 a = 30 ft Distance to measure roof zones d1 = d2 = E =1.5 d1 to the adjacent array > max(4h2, 4 ft), or d2 to the next adjacent panel > max(4h2, 4ft) W L =60 ft Width of overall longest side, in ft W S =50 ft Width of overall shortest side, in ft GCrn= Net pressure coefficient, equal topE((GCrn)nom(c)) (GCrn)nom=Nominal Net pressure coefficient lp =3.25 ft Chord length of solar panel, in ft perpendicular to edge lmodule =4 Module chord length (trib W) W module 2.705 Module length (1/2 panel) c 0.8 Panel chord length factor, max(0.6+0.06lp,0.8) For 5o < < 15o, apply c only to 15o - 35o (GCrn)nom figure values and prior to interpoating p 0.9 Parapet height factor, equal to min(1.2,0.9+hpt/h) 5 Angle of plane of roof from horizontal, in degrees 0 Angle of plane of panel to roof, in degrees Determine Lb Lb= 0.5*sqrt(hWL), but need not exceed h or Ws, in ft Lb=15.0 ft, not to exceed 15 or 50 ft Lb=15.0 ft Determine Roof Zones 2h 30 ft: Roof zone 2 and 3 setback (indicated by the dotted lines on Figure 3) Panels located beyond 30 ft setback are located in Roof Zone 1. Effective Wind Area (A) of attachment or ballast: A = lmodule*W module =4 ft x 2.705 ft A = 8.79 sf Calculate the Normalized Wind Area (An) An = (1000/(max(Lb, 15ft))2)*A =(1000/(15ft)^2)*8.79 sf An =39.07 sf ASCE 7-16 For rooftop solar array, horizontal distance orthogonal to the panel edge to an adjacent panel or the building edge, ignoring any rooftop equipment in Fig. 29.4-7, in ft For rooftop solar arrays, horizontal distance from the edge of one panel to the nearest edge in the next row in Fig. 29.4-7, in ft 1.5 for uplift loads on panels that are exposed and within a distance 1.5Lp from the end of a row at an exposed edge of the array; E =1.0 elsewhere for uplift loads and for all downward loads, as illustrated in Fig. 29.4-7. A panel is defined as exposed if d1 to the roof edge > 0.5h and one of the following applies: 1422 W Marion Way1/24/2025 (GCrn)nom Roof Zone 1 0.82 Roof Zone 2 1.09 Roof Zone 3 1.24 GCrn=(c)(p)(E)(GCrn)nom GCrn GCrn Exposed 1.18 Zone 2 Non Exposed 0.59 Zone 1 1.34 Zone 3 0.78 Zone 2 Velocity pressure Exposure Coefficients qh = 0.00256KzKztKdKeV2 Kzt =1 V = 95 mph Kd =0.85 qh = 16.7 psf Kz =0.85 Ke =1 Non Exposed Exposed p (psf) = 9.853 Zone 1 13.026 19.706 Zone 2 22.378 Zone 3 Non Exposed Exposed 0.6W 10 Zone 1 10 11.8236 Zone 2 13.4268 Zone 3 <--- Use Zone 3 Exposed 1422 W Marion Way1/24/2025 Soil Site Class = D Risk Category = II SS = 1.671 Mapped Spectral Response acceleration in short periods S1 = 0.614 Mapped Spectral Response acceleration at one second periods SS< 0.25 SS= 1.0 SS>1.25 SS>1.5 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.3 1.2 1.2 1.2 1.6 1.1 1.0 1.0 2.4 - - - ---- Fa = 1.200 (interpolated) SMS = Fa*SS = 2.005 Min. 1.2 per 11.4.3 S1< 0.1 S1= 0.4 S1>0.5 S1>0.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.5 1.5 1.5 1.4 2.4 1.6 1.5 1.7 4.2 - - - ---- Fv = 1.700 (interpolated) SM1 = Fv*S1 = 1.044 SDS = 2/3 *SMS = 1.337 SD1 = 2/3 *SM1 = 0.696 SDS RISK CATEGORY SD1 RISK CATEGORY > I, II III IV > I, II III IV 0A A A 0A A A 0.167 B B C 0.067 B B C 0.33 C C D 0.133 C C D 0.5 D D D 0.2 D D D Seismic Design Category = D ASCE 7-16 Table 1613.2.3(1) Values of Site Coefficient Fa F- 1.2 SITE CLASS SS= 0.5 SS= 0.75 A 0.8 0.8 B 1.2 0.9 D 1.4 0.9 0.8 0.8 1.3 Table 1613.2.3(2) 0.8 Values of Site Coefficient Fv S1= 0.2 S1= 0.3SITE CLASS 1.7 A 0.8 1.3 C E - 1.5 1.5 B E-- F-- 2.2 2.0D C 1422 W Marion Way1/24/2025 Soil Site Class D Risk Category = II Seismic Design Category = Null I=1 SS = 1.671 S1 = 0.614 SMS = 2.005 SM1 = Null R = 6.5 Height = 11.375 T = 0.035*hn^.75 = 0.21679 r (Reliability/Redundancy Factor) = 1 SDS = 1.337 SD1 = Null Equivalent Lateral Force procedure (ASCE 7-16 12.8-2)Cs = SDS/(R/I) =Cs *W (ASCE 7-16 12.8-3)Cs <= SD1/[(R/I)T] = 0.2057 W (ASCE 7-16 12.8-5)Cs >= .01 = Null W If S1>0.6g = 0.01 W (ASCE 7-16 12.8-5)Cs >= 0.5*S1/[R/I] = 0.047 W V(controls) = 0.2057 W Determine Fp for seismic loading on attachments Seismic Load on Nonstructural Components Spacing of attachments 5.33 ft Tributary width of attachments = 1/2 Panel length = 33.9 in Ap =15.1 ft2 PV unit weight including racking = 3 psf W p =45.17175 lb Other mechanical/electrical components ap =1 Fp = 0.4apSDS*Wp/(Rp/Ip)(1+2z/h)48.32 lb 13.3-1 Rp =1.5 Ip =1 Fp <= 1.6SDS*IpW p 96.63 lb 13.3-2 SDS = 1.337 Wp = 45.17175 lb Fp >= 0.3SDS*IpW p 18.12 lb 13.3-3 z= 22 ft h= 22 ft ASCE 7-16 1422 W Marion Way1/24/2025 SHEET: 5 OF 7 DATE: DE JOB NO.: DESIGN LOADS Dead Loads Uplift Roof 0.6WL ROLLED COMP 4.0 psf 0.6WL Zone 3 -13.43 psf, MIN 10 PSF 5/8" Ply shtg 1.9 Rf Frm'g 2.8 pWLdown =6.4 psf 10 psf, MIN 10 PSF Misc. 1.5 Uplift 0.6DL+0.6WL (N) PV System 3.0 Zone 3 0.6*3 -13.4268 -11.6 psf Total DL 13.2 psf Downward DL+0.6WL LL 20.0 psf PDL+WL =13.0 psf SNOW 0.0 psf Rafter Check Existing 2x4 RAFTERS @ 16" o.c Spacing 1.33 ft Trib panel width = 5.33 ft E 1500000 psi Fb =900*1.5*1.15 1553 psi I5.4in^4MallowWind =1110 ft-lb Span1 6.92 ft MallowLL =867 ft-lb Span2 6.92 ft See below for Wind Uplift loads Span3 0.00 ft due to concentated loads at attachments Span4 0.00 ft (Distance to Att. Pts)a b R1 (lb) R2 (lb Load (psf) Trib W (ft) Wind Uplift (lb) Mmax wind(ft- lb) Wind Down (lb) P = PVDL (lb) 1.00 1 1.99 1.99 4.93 144.0 58.1 13.427 5.3 202.2 287 150.6 45.2 195.7 2 5.63 5.63 1.29 37.7 164.5 13.427 5.3 202.2 212 150.6 45.2 195.7 3 7.62 0.70 6.22 181.7 20.5 13.427 5.3 202.2 127 150.6 45.2 195.7 4 11.26 4.34 2.58 75.4 126.8 13.427 5.3 202.2 327 150.6 45.2 195.7 12.25 Span 1 Uniform DL 6.92 28.2 28.2 6.1 psf 1.3 8.2 plf 48.8 Span 2 Uniform DL 6.92 28.2 28.2 6.1 psf 1.3 8.2 48.8 Reactions at Span1 210.0 250.9 Negative values are uplift reactions Reactions at Span2 103.6 155.0 Mmaxwindup = 241 ft-lb < 1110 ft-lb OK Mmaxwinddown = 417 ft-lb < 1110 ft-lb OK For DL+LL including the PV system weight point loads w = 40.3 plf P = 45.2 lb Mmax =315 ft-lb < 867 ft-lb OK Deflection Check DDL = 5wL4/(384EI)(5*13.2*6.92^4)*1728 = 0.113 in = L/ 735 OK 384*1.5E6*5.4 PROJECT: CLIENT: BY: PV Panels for Robert Dominguez Guyou Construction, Inc. Doug Engineering 11/26/2024 GUC-3004 P = DL+WL (lb) 1422 W Marion Way1/24/2025 SHEET: 6 OF 7 DATE: DE JOB NO.: CHECK SCREW ATTACHMENTS FOR WIND UPLIFT Pwuplift =202.2 lb 5/16" Lag with min 1.5" penetration for each attachment Table 12.2A - NDS - Lag Screw Withdrawal Values For 5/16" Lag into .5G wood 266 lb Allowable wind load = 1.6*1.5*266 638.4 lb > 202.2 lb OK CHECK SCREW ATTACHMENTS FOR SHEAR DUE TO SEISMIC Fp Fp = 48.32 lb Roof slope/module tilt 5 deg Shear = Fp*cos( 5 ) = 48.1 lb Fp sin(ang) Tension = Fp*sin( 5 ) = 4.2 lb Fp cos(ang) Table 11K - NDS Z = 190 lb CD = 1.6 ` Z' = Z*CD =304 lb > 48.1 lb OK Withdrawal capacity W' = 638.4 lb Interaction Equation ft/Ft+fv/Fv 0.323 + 0.158 = 0.481 < 1 OK RAIL SPAN CHECK Unirac NXT Rail check Invisimount Rail Properties Tributary width = half a panel Moment of Inertia I = 0.2 in^4 wtrib =2.825 ft Section Modules S = 0.168 in^3 Uniform Load = wind load * wtrib Yield Strength y =35000 psi wSWH =42 plf Tensile Strength u =38000 psi Span = distance between attachment points = L Masd allow = 0.6*y*S 294 lb-ft L = 5.33 ft MSWH = Wswh*L2/8 150.5 lb-ft < 294 lb-ft OK 11/26/2024 GUC-3004 PROJECT: CLIENT: BY: PV Panels for Robert Dominguez Guyou Construction, Inc. Doug Engineering 1422 W Marion Way1/24/2025 SHEET: 7 OF 7 DATE: DE JOB NO.: LATERAL ANALYSIS DETERMINE ADDITIONAL LOAD COMPARED TO EXISTING FOR LATERAL LOADING Aroofexisting== 2090 sf W panel =47.4 lb W roofexisting =10.2*2090 = 21318 lb 14 *W panel = 663.6 lb W wallexisting =15*80*4 = 4800 lb W restofarray =218.4 lb W existing =26118 lb W array = 882 lb V = 0.206 W Vroofexisting =5380 lb Existing Total Lateral Force Vroofwpanels =5562 lb New Total Later Force % increase = 5562 increase which results in less than a 10% increase in the 5380 stress of existing lateral resisting elements OK *100%-100% = 3% BY: Doug Engineering GUC-3004 PROJECT: PV Panels for Robert Dominguez CLIENT: Guyou Construction, Inc. 11/26/2024 1422 W Marion Way1/24/2025 Owner: Robert Dominguez Address: 1422 Marion Way West, Santa Ana, CA 92706 Sheet Item 1-2 Wind parameters 3-4 Seismic parameters and determination of Fp 5 design loads, roof member check, wind uplift check, deflection 6 attachment check, rail span check 7 lateral check 8 Battery attachment check Project Number: GUC-3004 Date: Revised: BASIS FOR DESIGN CODE:2022 California Building Code ASCE 7-16 LIVE LOADS ROOF 20.0 psf SNOW 0.0 psf 1/13/2025 CALCULATIONS FOR SOLAR PHOTOVOLTAIC PANELS: INDEX TO CALCULATIONS Engineering Calculations Performed By: Doug Engineering 5 Via Belmonte, Rancho Santa Margarita, CA 92688 949-285-5104 Engineering Calculations For: Guyou Construction, Inc. 9880 Indiana Avenue, Suite 2, Riverside, CA 92503 (866) 464-8968 11/26/2024 1422 W Marion Way1/24/2025 FLUSH MOUNTED SOLAR PANELS Type of Roof Gable Roof Slope - = Angle of plane of roof from horizontal, in degrees =5 deg Mean Roof Height - Eave height will be used for <= 10deg h = 22 ft Building dimensions s1 = 30 ft s2 = 30 ft a = 10% of least horizontal dimension or 0.4h, whichever is smaller, but not less than 4% of the least horizontal direction or 3 ft a = 3 ft B = Horizontal dimension of building normal to wind direction, in ft. B = 20 ft Horizontal dimension of building Attachment Spacing Effective Area A = 13 ft2 p = qh(GCp)(E)(a)29.4-7 Velocity pressure Exposure Coefficients ROOF OVERHANG Wind Exposure C (GCp)down = 0.51 0.51 Kzt =1 (GCp)upz1 = -2 -2.5 Kd =0.85 (GCp)upz2e = -2 -2.5 Kz =0.85 (GCp)upz2n = -2.84 -3.38 Ke =1 (GCp)upz2r = -2.84 -3.38 E =1 (GCp)upz3e = -2.84 -3.89 a = 0.75 (GCp)upz3r = -3.39 -4.43 V = 95 mph qh = 0.00256KzKztKdKeV2 qh = 16.7 psf p = 12.525 *(GCp) FIGURE 30.3-2A Components & Cladding h<= 60 ft: External Pressure Coefficients, (GCp), for Enclosed and Partially Enclosed Buildings - Gable roofs 0<=7deg ASCE 7-16 1 1422 W Marion Way1/24/2025 Wind Pressures Wind Down - All Zones 6.4 psf 10 psf, MIN ROOF OVERHANG Zone 1 -25.05 psf -31.31 psf Zone 2e -25.05 psf -31.31 psf Zone 2n -35.57 psf -42.33 psf Zone 2r -35.57 psf -42.33 psf Zone 3e -35.57 psf -48.72 psf Zone 3r -42.46 psf -55.49 psf All panels are in Zones 1 and 2e ROOF OVERHANG Use -25.05 psf -31.31 psf 0.6*W -15 psf -18.8 psf ASCE 7-16 2 1422 W Marion Way1/24/2025 Soil Site Class = D Risk Category = II SS = 1.671 Mapped Spectral Response acceleration in short periods S1 = 0.614 Mapped Spectral Response acceleration at one second periods SS< 0.25 SS= 1.0 SS>1.25 SS>1.5 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.3 1.2 1.2 1.2 1.6 1.1 1.0 1.0 2.4 - - - ---- Fa = 1.200 (interpolated) SMS = Fa*SS = 2.005 Min. 1.2 per 11.4.3 S1< 0.1 S1= 0.4 S1>0.5 S1>0.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.5 1.5 1.5 1.4 2.4 1.6 1.5 1.7 4.2 - - - ---- Fv = 1.700 (interpolated) SM1 = Fv*S1 = 1.044 SDS = 2/3 *SMS = 1.337 SD1 = 2/3 *SM1 = 0.696 SDS RISK CATEGORY SD1 RISK CATEGORY > I, II III IV > I, II III IV 0A A A 0A A A 0.167 B B C 0.067 B B C 0.33 C C D 0.133 C C D 0.5 D D D 0.2 D D D Seismic Design Category = D 1.5 1.5 B E-- F-- 2.2 2.0D C 0.8 0.8 1.3 Table 1613.2.3(2) 0.8 Values of Site Coefficient Fv S1= 0.2 S1= 0.3SITE CLASS 1.7 A 0.8 1.3 C E -F- 1.2 SITE CLASS SS= 0.5 SS= 0.75 A 0.8 0.8 B 1.2 0.9 D 1.4 0.9 ASCE 7-16 Table 1613.2.3(1) Values of Site Coefficient Fa 1422 W Marion Way1/24/2025 Soil Site Class D Risk Category = II Seismic Design Category = Null I=1 SS = 1.671 S1 = 0.614 SMS = 2.005 SM1 = Null R = 6.5 Height = 11.375 T = 0.035*hn^.75 = 0.21679 r (Reliability/Redundancy Factor) = 1 SDS = 1.337 SD1 = Null Equivalent Lateral Force procedure (ASCE 7-16 12.8-2)Cs = SDS/(R/I) =Cs *W (ASCE 7-16 12.8-3)Cs <= SD1/[(R/I)T] = 0.2057 W (ASCE 7-16 12.8-5)Cs >= .01 = Null W If S1>0.6g = 0.01 W (ASCE 7-16 12.8-5)Cs >= 0.5*S1/[R/I] = 0.047 W V(controls) = 0.2057 W Determine Fp for seismic loading on attachments Seismic Load on Nonstructural Components Spacing of attachments 5.33 ft Tributary width of attachments = 1/2 Panel length = 33.9 in Ap =15.1 ft2 PV unit weight including racking = 3 psf W p =45.17175 lb Other mechanical/electrical components ap =1 Fp = 0.4apSDS*Wp/(Rp/Ip)(1+2z/h)48.32 lb 13.3-1 Rp =1.5 Ip =1 Fp <= 1.6SDS*IpW p 96.63 lb 13.3-2 SDS = 1.337 Wp = 45.17175 lb Fp >= 0.3SDS*IpW p 18.12 lb 13.3-3 z= 22 ft h= 22 ft ASCE 7-16 1422 W Marion Way1/24/2025 SHEET: 5 OF 8 DATE: DE JOB NO.: DESIGN LOADS Dead Loads Uplift Roof 0.6WL ROLLED COMP 4.0 psf 0.6WL Zone 3 -13.43 psf, MIN 10 PSF 5/8" Ply shtg 1.9 Rf Frm'g 2.8 pWLdown =6.4 psf 10 psf, MIN 10 PSF Misc. 1.5 Uplift 0.6DL+0.6WL (N) PV System 3.0 Zone 3 0.6*3 -13.4268 -11.6 psf Total DL 13.2 psf Downward DL+0.6WL LL 20.0 psf PDL+WL =13.0 psf SNOW 0.0 psf Rafter Check Existing 2x4 RAFTERS @ 16" o.c Spacing 1.33 ft Trib panel width = 5.33 ft E 1500000 psi Fb =900*1.5*1.15 1553 psi I5.4in^4MallowWind =1110 ft-lb Span1 6.92 ft MallowLL =867 ft-lb Span2 6.92 ft See below for Wind Uplift loads Span3 0.00 ft due to concentated loads at attachments Span4 0.00 ft (Distance to Att. Pts)a b R1 (lb) R2 (lb Load (psf) Trib W (ft) Wind Uplift (lb) Mmax wind(ft- lb) Wind Down (lb) P = PVDL (lb) 1.00 1 1.99 1.99 4.93 144.0 58.1 13.427 5.3 202.2 287 150.6 45.2 195.7 2 5.63 5.63 1.29 37.7 164.5 13.427 5.3 202.2 212 150.6 45.2 195.7 3 7.62 0.70 6.22 181.7 20.5 13.427 5.3 202.2 127 150.6 45.2 195.7 4 11.26 4.34 2.58 75.4 126.8 13.427 5.3 202.2 327 150.6 45.2 195.7 12.25 Span 1 Uniform DL 6.92 28.2 28.2 6.1 psf 1.3 8.2 plf 48.8 Span 2 Uniform DL 6.92 28.2 28.2 6.1 psf 1.3 8.2 48.8 Reactions at Span1 210.0 250.9 Negative values are uplift reactions Reactions at Span2 103.6 155.0 Mmaxwindup = 241 ft-lb < 1110 ft-lb OK Mmaxwinddown = 417 ft-lb < 1110 ft-lb OK For DL+LL including the PV system weight point loads w = 40.3 plf P = 45.2 lb Mmax =315 ft-lb < 867 ft-lb OK Deflection Check DDL = 5wL4/(384EI)(5*13.2*6.92^4)*1728 = 0.113 in = L/ 735 OK 384*1.5E6*5.4 PROJECT: CLIENT: BY: PV Panels for Robert Dominguez Guyou Construction, Inc. Doug Engineering 11/26/2024 GUC-3004 P = DL+WL (lb) 1422 W Marion Way1/24/2025 SHEET: 6 OF 8 DATE: DE JOB NO.: CHECK SCREW ATTACHMENTS FOR WIND UPLIFT Pwuplift =202.2 lb 5/16" Lag with min 1.5" penetration for each attachment Table 12.2A - NDS - Lag Screw Withdrawal Values For 5/16" Lag into .5G wood 266 lb Allowable wind load = 1.6*1.5*266 638.4 lb > 202.2 lb OK CHECK SCREW ATTACHMENTS FOR SHEAR DUE TO SEISMIC Fp Fp = 48.32 lb Roof slope/module tilt 5 deg Shear = Fp*cos( 5 ) = 48.1 lb Fp sin(ang) Tension = Fp*sin( 5 ) = 4.2 lb Fp cos(ang) Table 11K - NDS Z = 190 lb CD = 1.6 ` Z' = Z*CD =304 lb > 48.1 lb OK Withdrawal capacity W' = 638.4 lb Interaction Equation ft/Ft+fv/Fv 0.323 + 0.158 = 0.481 < 1 OK RAIL SPAN CHECK Unirac NXT Rail check Invisimount Rail Properties Tributary width = half a panel Moment of Inertia I = 0.2 in^4 wtrib =2.825 ft Section Modules S = 0.168 in^3 Uniform Load = wind load * wtrib Yield Strength y =35000 psi wSWH =42 plf Tensile Strength u =38000 psi Span = distance between attachment points = L Masd allow = 0.6*y*S 294 lb-ft L = 5.33 ft MSWH = Wswh*L2/8 150.5 lb-ft < 294 lb-ft OK PROJECT: CLIENT: BY: PV Panels for Robert Dominguez Guyou Construction, Inc. Doug Engineering 11/26/2024 GUC-3004 1422 W Marion Way1/24/2025 SHEET: 7 OF 8 DATE: DE JOB NO.: LATERAL ANALYSIS DETERMINE ADDITIONAL LOAD COMPARED TO EXISTING FOR LATERAL LOADING Aroofexisting== 2090 sf W panel =47.4 lb W roofexisting =10.2*2090 = 21318 lb 14 *W panel = 663.6 lb W wallexisting =15*80*4 = 4800 lb W restofarray =218.4 lb W existing =26118 lb W array = 882 lb V = 0.206 W Vroofexisting =5380 lb Existing Total Lateral Force Vroofwpanels =5562 lb New Total Later Force % increase = 5562 increase which results in less than a 10% increase in the 5380 stress of existing lateral resisting elements OK BY: Doug Engineering GUC-3004 PROJECT: PV Panels for Robert Dominguez CLIENT: Guyou Construction, Inc. 11/26/2024 *100%-100% = 3% 1422 W Marion Way1/24/2025 SHEET: 8 OF 8 DATE: DE JOB NO.: BATTERY ATTACHMENT CHECK HORIZONTAL AND LATERAL LOADS 287 lb TESLA POWERWALL 3 Weight = 287 lb 1.5 ft Number of screws 4 Shear acting on all screws = 287lb/ 71.75 lb, minimal, OK Withdrawal acting on 2 screws due to eccentric load = eccentricity = 6.1"/2 3.05 in Eccentric Moment = 72.946 ft-lb Distance between brackets = 1.5 ft Total load distributed between 2 screws at the top bracket = 48.6 lb Load per screw = 24.3 lb Check 1/4" or M6 screws For 1/4" Lag into .5G wood 200 lb 1/4" Lag with min 2" penetration for each attachment Capacity per screw 500 lb Z' = Z*CD =170*1 lb > 170 lb OK Interaction Equation ft/Ft+fv/Fv 0.0486 + 0.42206 = 0.4707 < 1 OK BY: Doug Engineering GUC-3004 PROJECT: PV Panels for Robert Dominguez CLIENT: Guyou Construction, Inc. 11/26/2024 1422 W Marion Way1/24/2025 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.Will the PV system weigh maximum 4 pounds per square feet or less? 5.Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.Will the PV system be installed without using any ballast system or counter-weight system? 8.Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1422 MARION WAY WESTSANTA ANA, CA 92706 GUYOU CONSTRUCTION INC 997054 DAVID VITELA 657-224-2652 12/02/2024 permits@guyouconstruction.com 1422 W Marion Way1/24/2025 A B -- ISSUED FOR: PERMIT DATE: SR P RR R S 11/26/2024 ROBERTO DOMINGUEZ 1422 MARION WAY WESTSANTA ANA, CA 9270624-1937 (714)-742-42569880 I A , S 2R , CA 92503P R : (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XGUYOU CONSTRUCTION,INC.PV-1 PROJECT INFORMATION/SCOPE OF WORK VICINITY MAP SHEET INDEX APPLICABLE CODES PLAN SET LEGEND SUB SERVICE PANEL AC DISCONNECT DC DISCONNECT SOLAR COMBINER BOX INVERTER SUB AC DC SLC INV JUNCTION BOXJB ABBREVIATIONS EXTERIOR INTERIOR EXT INT NEW(N) EXISTING(E) ELECTRICAL METALLIC TUBINGEMT RIGID METALLIC CONDUITRMC VOLTAGE OPEN CIRCUITVOC VOLTAGE AT MAX. POWERVMP SHORT CIRCUIT CURRENTISC CURRENT AT MAX. POWERIMP AHJ NOTES PV MONITORINGM NOT TO SCALENTS MAIN SERVICE PANEL MSP PROJECT INFORMATION PV-1 PROJECT INFORMATION PV-1A SITE PLAN, HOUSE PHOTO PV-1B FIRE ACCESS PATHWAY PLAN PV-2 ROOF PLAN PV-2A ATTACHMENT DETAILS PV-2B BATTERY DETAILS PV-3 ELECTRICAL LINE DIAGRAM & ELECTRICAL CALCULATIONS PV-3A ELECTRICAL NOTES PV-4 & 4A REQUIRED SIGNAGE ENPHASE AC SOLAR PVENCOMBINER BOX PROJECT SITE FLEXIBLE METALLIC CONDUITFMC PERFORMANCE METER STORAGE BATTERYBAT PLP PROTECTED LOAD PANEL AUTHORITY HAVINGAHJ JURISDICTION RIGID GALVANIZED STEELRGS ENERGY STORAGEESS SYSTEM 14 X 400 W LONG G E T R R CR., L . LR5-54HABB-400M ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 14 X 290 W E E IQ8PLUS-72-2-US (SI1-JUN20) (240V) SYSTEM SIZE: 5.600 W DC STC, 5.083 W CEC-AC ARRAY AREA: 294 SF PANEL UPGRADE:225 A AHJ:CITY OF SANTA ANA APN:001-055-05 ROBERTO DOMINGUEZ 1422 MARION WAY WEST SANTA ANA, CA 92706 INSTALLATION OF NEW SOLAR PV & ESS SYSTEM: ALL WORK TO COMPLY WITH THE FOLLOWING CODES: 2022 CA BUILDING CODE 2022 CA RESIDENTIAL CODE 2022 CA MECHANICAL CODE 2022 CA ELECTRICAL CODE 2022 CA GREEN CODE 2022 CA PLUMBING CODE 2022 CA ENERGY CODE 2022 CA FIRE CODE LOCAL JURISDICTION AMENDMENTS GAT TESLA BACKUP GATEWAY 2 1 X TESLA BACKUP GATEWAY 2 LATITUDE 33.767250 - LONGITUDE -117.887090 OCCUPANCY: R-3 CONSTRUCTION TYPE: VB UNSPRINKLERED 1 X TESLA POWERWALL 3 BATTERY PER SECTION R314 AND R315 OF CRC 2022, IT'S REQUIRED THAT SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLING FOR A PERMIT WITH REPAIRS OR ADDITIONS EXCEEDING 1,000. ALL NEW UTILITY CONNECTIONS ARE REQUIRED TO BE INSTALLED BELOW GRADE BY SANTA ANA MUNICOPAL CODE 41-626(B). THERE IS A STANDING EXCEPTION FOR EXISTING ONE AND TWO FAMILY DWELLINGS. THIS EXCEPTION APPLIES ONLY WHEN THE NEW ELECTRICAL SERVICE IS DESIGNATED TO BE FED FROM BELOW GRADE AS WELL AS OVERHEAD. ONLY LISTED COMBINATION OVERHEAD AND UNDERGROUND FEED SERVICE BOXES MAY BE USED TO CONNECT TO AN OVERHEAD UTILITY DROP. THIS EXCEPTION TO AN UNDERGROUND FED SERVICE APPLIES ONLY TO EXISTING SINGLE FAMILY AND TWO FAMILY RESIDENCES. **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. ** Bldg#:101121871 Elec#: 20184663 Approvals: Bldg: T Le Elec: M Smith 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.SCALE: 1":15'-0" N SCALE: N.T.S.HOUSE PHOTOSITE PLAN PV-1ASITE PLAN, HOUSE PHOTOARRAY LOCATION BRANCH CIRCUIT # OF PANELS TILT, AZIMUTH 17 5°, 180° 27 5°, 180° dKd>ηK& WE>^ϭϰ 4 2 3 (E) ONE-STORY HOUSE (N) SOLAR PV ARRAY PER TABLE BELOW FIRE ACCESS POINT 1 2 3 SITE PLAN LEGEND (E) DRIVEWAY 4 5 6 1 (N) PV & ESS EQUIPMENT TOTAL ROOF AREA:2,090 SF TOTAL MODULE AREA: 294 SF TOTAL ROOF COVERAGE:14.1 % (E) DETACHED GARAGE SEE PV1B FOR FIRE ACCESS PATHWAYS PV-2 FOR ROOFTOP EQUIPMENT CALLOUTS AND ROOF AND ARRAY DIMENSIONS. 6 MICROINVERTERWITH BUILT INRAPID SHUTDOWNLOCATED AT EACHMODULE MSPAC BAT ACPLPGAT5 5 33'-3"11'-11" 5'-0"17'-8"63'-8"101'-4"101'-4"63'-8" B1 B1 B1B1 B1 B1 B2 B2B2 B2B2 B2B2 B1 MARION WAY WEST PL PLPL PL EN A 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.SCALE: 1":10'-0"ROOF PLAN N ARRAY & ROOF INFO MODULE TYPE, DIMENSIONS & WEIGHT PV-2ROOF PLAN1 1 LAYER OF ROLLED COMP 2x4 RAFTERS @ 16" o.c 180 5 635 180 5 294 14.1% 14 64 Roof Plane Roof Type: Roof Framing: Roof Azimuth (deg): Roof Slope (deg): Roof Area (sf): Array Azimuth (deg): Array Tilt (deg): Array Area (sf): % Coverage of Roof # of Panels Attachment spacing (in): PANEL TYPE: LR5-54HABB-400M PANEL WEIGHT: 49.6 LB PANEL DIMENSIONS: 67.8 IN. X 44.7 IN. PANEL AREA:21.00 SF UNIT WEIGHT OF PANELS:49.6LB/21SF = 2.36 PSF RACKING 0.19 PSF AREA PER ATTACHMENT: 5.33'X2.83' = 15.1 SF WEIGHT PER ATTACHMENT: 15.1SFX2.55PSF = 40.8 LB FIRE ACCESS POINT1 2 3 ROOF PLAN LEGEND 1 2 4 (N) CONDUIT ROUTE MICROINVERTERWITH BUILT INRAPID SHUTDOWNLOCATED AT EACHMODULE (E) INTERIOR RAFTER SUPPORT 5 6 3 ACCESSES IDENTIFIED ARE AT STRONG POINTS OF ROOF WHICH DO NOT HAVE OPENINGS BELOW LADDER ACCESSES. PER CRC R331.4.1. (E) RISER (E) EXTERIOR WALL (E) PLUMBING VENT 4 5 7 7 (E) CHIMNEY 8 (E) AC UNIT ALL ARRAY AND ROOF INFORMATION IS SHOWN TO THE RIGHT INCLUDING FRAMING AND ATTACHMENT SPACING. CONDUIT SHALL BE EMT CONDUIT (EXTERIOR) OR EMT OR FMC AS AHJ ALLOWS (INTERIOR), CONTRACTOR TO RUN CONDUIT ON ROOF AND UNDER EAVES OR WITHIN ATTIC. CONDUIT RUN TO BE DETERMINED AT THE TIME OF INSTALL. ANY EXPOSED CONDUIT SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE. 6 8 1'-6"6'-11"6'-11"1'-8"2'-5"10'-0"MSPEN ACPLPGATAC JB R1 SLOPE5'-4"4'-0"A BAT 1422 W Marion Way1/24/2025 AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.SCALE: 1":15'-0" N FIRE ACCESS PATHWAYS & RIDGE SETBACK PLAN PV-1BPATHWAY PLANTOTAL ROOF AREA:2,090 SF TOTAL MODULE AREA:294 SF TOTAL ROOF COVERAGE:14.1 FIRE ACCESS R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCHWIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A MINIMUM 36-INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. R324.6.2 SETBACK AT RIDGE: FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN AN 18-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN A 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING: PANELS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. LEGEND PATHWAY ON STREET OR DRIVEWAY1 SIDE OF THE ROOF FIRE ACCESS POINT2 18" SETBACK TO HIP/VALLEY 1 36" FIRE ACCESS PATHWAYS 18" SETBACK ON BOTH SIDES OF RIDGE PER R324.6.2 2 3 (E) ROOF SLOPE LESS THAN 2:123 R324.6.2 RIDGE SETBACK EXCEPTION: 2:12 (9.5) OR LESS ROOF SLOPES 1422 W Marion Way1/24/2025 UNIRAC STRONGHOLD BUTYL UNIRAC NXT UMOUNT RAIL 5/16" STAINLESS STEEL LAG BOLTMIN. 1.5" PENETRATION SEALED W/ BUTYL SEALANT (E) ROOF FRAMING, SEE ROOF INFO MATCH (E) ROOF SLOPEPV MODULES ATTACHMENTS 0' -4" UNIRAC STRONGHOLD CLAMP AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.EXISTING 2"X4" RAFTERS @ 16" O.C. (E) INTERIOR WALL 6'-11"6'-11" 2"x4" PURLIN NEW 225A /200A MAIN BREAKER 120/240V 1ɸ 3W OVERHEAD MAIN SERVICE PANEL & METER SOUTH WALL OUTSIDE NEW 30A PV DISCONNECT NEW TESLA POWERWALL 3 INVERTER / BATTERY WEST WALL OUTSIDE Gas EXISTING GATE NEW TESLA GATEWAY 2 NEW PROTECTED LOAD PANEL EXISTING WINDOW NEW 60A BATTERY DISCONNECT EXISTING WINDOW NEW ENPHASE AC COMBINER BOX TESLA POWERWALL 3 BATTERY1/4" LAG SCREWS 2 PER END (E) 2X4 WALL STUD @ 16" o.c. PV-2AATTACHMENT DETAILSSCALE: 1/2" = 1'-0"ATTACHMENT DETAIL SCALE: 3/8" = 1'-0"EQUIPMENT ELEVATION DETAIL SCALE: 1/2" = 1'-0"RAFTER SECTION DETAIL 3'-0"1'-0"BATTERY MOUNT DETAIL SCALE: N.T.S A 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.SINGLE LINE DIAGRAMSCALE: N.T.S.ELECTRICAL SINGLE LINE DIAGRAM PV-3 STRINGS CONNECTED IN PARALLEL SEE PV-3A FOR ELECTRICAL NOTES >KtDEdDWWZ ^,Z,EKK< D&ZsK>d'dDW K&&//Ed;ŽͿ sK>d'>KtdDW͘ KZZ͘;ŽͿ ,/',D/EddDW ;ŽͿ KEh/d,/',d ;ŝŶͿ ZKK&dKWdDWWZ dĂďůĞϯϭϬ͘ϭϱ;Ϳ;ϯͿΞ;ŽͿ :h^ddDW dDW KZZd/KE ZKK&Ϯ -0.265 1.06 ϯϭ KsϳͬϴΗD/E͘Ϭϯϭ͘ϵϲ t>>Ϯ ϯϭ EͬϬϯϭ͘ϵϲ 5.600kW DC STC, 5.083 kW CEC-AC SOLAR ARRAY 14 LONGi Green Energy Technology Co., Ltd. 400W MODULES TOTAL TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1PH, 120/240V, 3W (N) 225A MAIN SERVICE PANEL (N) MAIN SERVICE DISCONNECT 240V, 200A NOT CENTER FED PANEL DECAL LONGi Green Energy Technology Co., Ltd. LR5-54HABB-400M 400W Vmp= 30.94V Voc= 37.05V Isc= 13.72A Imp= 12.93A CEC PTC POWER=374.3W Enphase Energy IQ8PLUS-72-2-US (SI1-JUN20) (240V) INVERTER MAX DC VOLTAGE: 60V DC VOLTAGE INPUT RANGE: 25-58V @240V PEAK POWER TRACKING VOLTAGE: 29-45V @240V AC NOMINAL VOLTAGE/RANGE: 211-264V @240V MAX AC OUTPUT CURRENT: 1.21A CEC WEIGHTED EFFICIENCY: 97% @240V BRANCH CIRCUIT # OF PANELS TILT, AZIMUTH 17 5°, 180° 27 5°, 180° dKd>ηK& WE>^ϭϰ 600 V, NEMA 3R W/ EUROSTRIP OR POLARIS IT CONNECTORS JUNCTION BOXA ELECTRICAL EQUIPMENT CALLOUTS B Ϭ͘ϮϵŬt/EsZdZhE'ZKhE EW,^EZ'z/YϴW>h^ͲϳϮͲϮͲh^ ;^/ϭͲ:hEϮϬͿ;ϮϰϬsͿ;ϮϰϬsͿ/EsZdZϮϰϬs͕ ϭ͘ϮϭEDϯZ͕h>>/^d͕;t/d, /Ed'Zd/^KEEdͿ t/Z d'η KEh/d t/ZYdz ;ZZz hZZEdͿ t/Z 'h' ;t'Ϳ t/ZdzW t/Z >E'd, ;&dͿ dDW Zd/E'͗ t/Z >Kd/KE :h^d t/ZdDW t/Z DW dDW KZZd/KEWZ d> ϯϭϬ͘ϭϱ;Ϳ;ϮͿ;ĂͿ͗ KEh/d&/>>WZ dĂďůĞ ϯϭϬ͘ϭϱ;Ϳ;ϯͿ;ĂͿ͗ t/Z KW͗ dZD/E> ϳϱŽZd/E'/EsZdZYdz͗KhdWhd hZZEd ϲϵϬ͘ϴ;Ϳ ^dZ/E' DW^ 'ZKhE ^/ 'ZKhE dzWKW,< ϭEKE Ϯ ϭϮ dZhE< >ϭϱ ϵϬΣ ZKK& ϯϭ ϯϬ y Ϭ͘ϵϲ y ϭ с Ϯϴ͘ϴ Ϯϱ ϳ y ϭ͘Ϯϭ y ϭ͘Ϯϱ с ϭϬ͘ϱϵ ηϲ ^ EKE Ϯ ϯͬϰΗDd ϰϭϬd,tEͲϮ ϳϬ ϵϬΣ ZKK& ϯϭ ϰϬ y Ϭ͘ϵϲ y Ϭ͘ϴ с ϯϬ͘ϳϮ ϯϱ ϳ y ϭ͘Ϯϭ y ϭ͘Ϯϱ с ϭϬ͘ϱϵ ηϴ d,tEͲϮ ϮϬϮW ϳyϭ͘Ϯϭ yϭ͘Ϯϱ с ϭϬ͘ϱϵ ηϴ d,tEͲϮ ϮϬϮW ϮĂ ϯͬϰΗDd ϯϲd,tEͲϮ ϭϬ ϵϬΣ t>> ϯϭ ϳϱ y Ϭ͘ϵϲ y ϭсϳϮϲϱ ϭ y ϰϴ y ϭ͘Ϯϱ с ϲϬ ηϴ d,tEͲϮ ϲϬϮW ϯ ϯͬϰΗDd ϯϭϬd,tEͲϮ ϱ ϵϬΣ t>> ϯϭ ϰϬ y Ϭ͘ϵϲ y ϭсϯϴ͘ϰ ϯϱ ϭϰ y ϭ͘Ϯϭ yϭ͘Ϯϱ с Ϯϭ͘ϭϴ ηϴ d,tEͲϮ ϮϱϮW ϰ ϭϭͬϰΗDd ϯϯd,tEͲϮϱ ϵϬΣ t>> ϯϭ ϭϭϱ y Ϭ͘ϵϲ y ϭ с ϭϭϬ͘ϰ ϭϬϬ ;ϮϮyϭ͘ϮϭͿн;ϰϴͿ y ϭ͘Ϯϱ с ϴϭ͘ϭϴ ηϴ d,tEͲϮ ϭϬϬϮW C AC DISCONNECT 240 VAC, 60A NEMA 3R, UL LISTED ENPHASE COMBINER BOX, 125A ENPHASE IQ COMBINER 4 X2-IQ-AM1-240-4 240V, NEMA 3R, UL 1741 2-POLE 100A GATEWAY BREAKER,BOND TO EXISTING UFER DyWssK>d'ΘhZZEd>^͗ RECORD LOW TEMP (˚C): (PER ASHRAE HANDBOOK)Ϯ TEMP COEFFICIENT (Voc) PER MANUFACTURER:ͲϬ͘Ϯϲϱйͬ VOLTAGE CORRECTION:ϭ͘Ϭϲ DyWs^z^dDsK>d';WZϮϬϮϮϲϵϬ͘ϳͿ͗ ;sĐŽƌƌĞĐƚŝŽŶΎsŽĐͿ ;ϭ͘ϬϲΎϯϳ͘ϬϱͿсϯϵ͘ϯs DyWsKEd/EhKh^hZZEdWZϮϬϮϮ ϲϵϬ͘ϴ;Ϳ;ϭͿ͗ ϭ͘Ϯϱy/ƐĐyη^dZ/E'^ ϭ͘ϮϱΎϭϯ͘ϳϮсϭϳ͘ϭϱ CT CT CT CT CT MONITOR AUTOMATIC TRANSFER SWITCH CTRL H + - CTRL F BATTERY BREAKER 240 V, A, 2P60 PV BREAKER 240 V, A, 2P25 G C D E PV BREAKER 240 V, A, 2P20 PV BREAKER 240 V, A, 2P20 MONITOR BREAKER 240 V, 15A, 2P JB A BRANCH CIRCUIT BB 1 MICROINVERTER PER PANEL2 BRANCH CIRCUIT BB 1 MICROINVERTER PER PANEL1 INTERCONNECTION METHOD PER 705.12(B)(3)(3): 100A GATEWAY BREAKER 50A AC UNIT BREAKER 150A </= 225A MAIN & BUS RATING, OK MODULES ARE CONNECTED IN PARALLEL, NOT IN SERIES. EACH MICROINVERTER IS EQUIPPED WITH RAPID SHUTDOWN CAPABILITIES. F TESLA POWERWALL 3 BATTERY AC OUTPUT:48A H TESLA BACKUP GATEWAY 2, NEMA 3R, WITH AUTOMATIC TRANSFER SWITCH G 125A PROTECTED LOAD PANEL WITH 100A MAIN BREAKER D BATTERY DISCONNECT 240 VAC, 60A NEMA 3R, UL LISTED E BOND #4 AWG TO UNDERGROUND WATER SERVICE LESS THAN 5' FROM WHERE IT ENTERS THE BUILDING 100A MAIN BREAKER NOTE: (E) BRANCH BREAKER RELOCATED FROM MAIN. IF EXTENDED BEYOND 6', 15A & 20A CIRCUITS SHALL BE COMBINATION-TYPE AFCI PROTECTED IN COMPLIANCE WITH NEC 210.12(B) A (N) 26 - #12 THWN-2, 6 - #10 THWN-2, 15 - #10 GND IN 1 1/2" EMT, L < 24" 1422 W Marion Way1/24/2025 AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-3AELECTRICAL NOTESELECTRICAL NOTES PER 2022 CEC, 690.64 (B)(7): LOCATE INVERTER OUTPUT AS FAR AS POSSIBLE FROM NORMAL POWER SUPPLY AT SERVICE PANEL. RELOCATION OF EXISTING CIRCUITS MAY BE NEEDED. DO NOT CHANGE PHASING OF MULTI-WIRE CIRCUITS. PERMANENT SIGNAGE AT PV SUPPLY CIRCUIT BREAKERS MUST SAY: WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. SIGNAGE TO BE LOCATED ADJACENT TO BACKFED BREAKER. ADDITIONAL AHJ REQUIRED ELECTRICAL NOTES 1. PV ARRAYS ARE PER SINGLE LINE.. 2. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 3. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER CEC 250.58. 4. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. 5. CONNECTORS SHALL BE POLARIS OR EUROSTRIP IT CONNECTORS. 6. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHED CUT SHEET. 7. AC DISCONNECT SHALL BE PER SINGLE LINE. 8. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO CEC 690. 9. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. 10. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5 11. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 12. ALL WORK TO COMPLY WITH 2022 CALIFORNIA ELECTRIC CODE, 2022 CALIFORNIA BUILDING CODE 13. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. 14. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. 15. CONDUCTORS ON ROOF ARE TO BE A MINIMUM OF 7/8" OFF OF THE ROOF SURFACE. 16.GEC TO BE CONNECTED TO EXISTING UFER. IF UFER IS NOT PRESENT THEN A NEW GROUND ROD WILL BE ADDED FOR GROUNDNG PURPOSES. 17. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS WHITE. 18. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE SMALLER THAN 14 AWG. 19. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. RACKING & MODULES ARE CONNECTED TO THE EGC W/ UNIRAC NXT UMOUNT LUG. MODULES ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS DC SIDE OF ARRAY IS UNGROUNDED AND THEREFORE GEC IS NOT REQUIRED. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES PER CEC 690.9 (A) GROUNDING: UNIRAC NXT UMOUNT LUG UL LISTED 2703 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.PV-3BPLP SCHEDULE PROTECTED PANEL LOAD CALCULATIONSPROTECTED PANEL LOAD CALCULATIONS ISSUEDFOR:PE24-1937PV-3BPLP SCHEDUAB1/9/2025-ERMITDATE:11/26/2024R14SA(7LE Solar PhotovROBERTO DOMINGUE422 MARION WAY WESTANTA ANA, CA 92706714)-742-4256voltaic SystemEZ98RivPhCSX_GIN880 Indiana Avenue, Suite 2verside, CA 92503hone:(866) 464-8968SLB #997054 (B,C-10,C-46,C-39)_______________________UYOU CONSTRUCTION,NC.)A 1422 W Marion Way1/24/2025 AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.PV-4REQUIRED SIGNAGEFRONT OF HOME CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: SOLAR ARRAY MAP PLACARD ON FACE OF THE MAIN SERVICE PANEL PER CEC 705.10: MSP6 MARION WAY WEST 1422 MARION WAY WESTSANTA ANA, CA 92706 YOU ARE HERE ON THE FACE OF THE MAIN SERVICE DISCONNECT PER CEC 690.13(B): PV SYSTEM DISCONNECT THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8" HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. ON FACE OF THE SERVICE METER PANEL: SIGNAGE AT MAIN SERVICE PANEL: MSP1 MSP2 MSP5 MSP3 MAXIMUM AC OPERATING CURRENT = 16.94A MAXIMUM AC OPERATING VOLTAGE = 240V RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM ON FACE OF THE SERVICE METER PANEL PER CEC 690.56 (C)(1)(a): SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 3/8" IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16" IN BLACK ON WHITE BACKGROUND. ON RAPID SHUTDOWN SWITCH LOCATED ON OR WITHIN 3' FROM SWITCH, IN 38" LETTERS IN WHITE ON RED BACKGROUND ON A REFLECTIVE LABEL PER CEC 690.56 (C)(3): MSP4 WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LOCATED AT BACKFED BREAKER PER CEC 705.12(B)(2)(3)(b): MSP7 ON FACE OF THE SERVICE METER PANEL PER CEC 705.10: CAUTION MULTIPLE SOURCES OF POWER SERVICE POINT & UTILITY METERING BATTERY DISCONNECT MSP8 WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR LOCATED AT MAIN SERVICE PANEL PER CEC 705.12(B)(3)(3):PV DISCONNECT PROTECTED LOAD PANEL GATEWAY PV COMBINER BOX STORAGE BATTERY A 1422 W Marion Way1/24/2025 AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-4AREQUIRED SIGNAGESIGNAGE AT COMBINER BOX/ SUBPANEL: E1 E2 ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): PV SYSTEM DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): ON FACE OF THE SUB PANEL: E3 E4 PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS ON FACE OF THE PV COMBINER PANELBOARD: MAXIMUM AC OPERATING CURRENT = 16.94A MAXIMUM AC OPERATING VOLTAGE = 240V SIGNAGE AT BATTERY STORAGE: ENERGY STORAGE SYSTEM DISCONNECT: NOMINAL ESS AC VOLTAGE =240 V MAXIMUM ESS DC VOLTAGE = F1 ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): 550 V F2 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): F3 ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): WARNING ENERGY STORAGE SYSTEM F4 BATTERY DISCONNECTING MEANS ON THE FACE OF THE BATTERY/ESS DISCONNECT PER 706.15(C): SIGNAGE AT AC DISCONNECT: C1 C2 ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): PV SYSTEM DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ON THE FACE OF THE PV DISCONNECT PER CEC 690.13(B): 1422 W Marion Way1/24/2025 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018)The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.IQ Combiner 4/4CTo learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Gateway for communication and control• Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C• Includes solar shield to match Enphase IQ Battery EIWXLIXMGWERHHIƥIGXLIEX• Supports Wi-Fi, Ethernet, or cellular connectivity• Optional AC receptacle available for PLC bridge• Provides production metering and consumption monitoringSimple• Mounts on single stud with centered brackets• Supports bottom, back and side conduit entry• Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included)• 80A total PV or storage branch circuitsReliableŵ (YVEFPI2680GIVXMƤIH2)1%X]TI6IRGPSWYVI• Five-year limited warranty• Two years labor reimbursement program coverage included for both the IQ Combiner SKU's•UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with -)))907&rd Ed.)X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018)Q-AM1-240-4C QAM12404C(IEEE 1547 2M1-240-4 2018)2018)-5''(7)297© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change.MODEL NUMBERIQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018)IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to HIƥIGXLIEXIQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018)IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the -5&EXXIV]ERH-57]WXIQ'SRXVSPPIVERHXSHIƥIGXLIEXACCESSORIES AND REPLACEMENT PARTS(not included, order separately)Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8)Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year AT&T data planCircuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B7YTTSVXW)EXSR&6&6&6&6&6&6ERH&6GMVGYMXFVIEOIVW Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit supportXA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C<%409+Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01)X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screwsConsumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP)A pair of 200A split core current transformersELECTRICAL SPECIFICATIONSRating Continuous dutySystem voltage 120/240VAC, 60 HzEaton BR series busbar rating 125AMax. continuous current rating 65AMax. continuous current rating (input from PV/storage) 64AMax. fuse/circuit rating (output)%Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. total branch circuit breaker rating (input)%SJHMWXVMFYXIHKIRIVEXMSR%[MXL-5+EXI[E]FVIEOIVMRGPYHIHIQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton includedProduction metering CT 200A solid core pre-installed and wired to IQ GatewayMECHANICAL DATADimensions (WxHxD)GQ\GQ\GQMR\MR\MR ,IMKLXMWGQMR [MXLQSYRXMRKFVEGOIXWWeight 7.5 kg (16.5 lbs)Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF)Cooling Natural convection, plus heat shieldEnclosure environmental rating3YXHSSV2680GIVXMƤIH2)1%X]TI6TSP]GEVFSREXIGSRWXVYGXMSRWire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors• 60A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductors• Always follow local code requirements for conductor sizing.Altitude9TXSQIXIVWJIIX INTERNET CONNECTION OPTIONSIntegrated Wi-Fi IEEE 802.11b/g/nCellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations.Ethernet3TXMSREP-)))'EX)SV'EX 984)XLIVRIXGEFPIRSXMRGPYHIH COMPLIANCECompliance, IQ Combiner CA Rule 21 (UL 1741-SA)-)))907&rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)'%2'7%'2S8MXPI'*64EVX'PEWW&-')7Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Consumption metering: accuracy class 2.5Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1IQ Combiner 4/4C-5''(7)2971422 W MarionWay1/24/2025 IQ8 and IQ8+ MicroinvertersOur newest IQ8 Microinverters are the industry’s first grid-forming microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesGrid-forming• Complies with the latest advanced grid support• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) requirements© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change.IQ8SP-DS-0002-01-EN-US-2021-10-19DATA SHEET(1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8 and IQ8+ MicroinvertersINPUT DATA (DC) IQ8-60-2-USIQ8PLUS-72-2-USCommonly used module pairings1W235 – 350 235 – 440Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cellMPPT voltage rangeV27 – 37 29 – 45Operating rangeV25 – 48 25 – 58Min/max start voltageV30 / 48 30 / 58Max input DC voltageV50 60Max DC current2 [module Isc]A15Overvoltage class DC portIIDC port backfeed currentmA0PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ8-60-2-USIQ8PLUS-72-2-USPeak output powerVA245 300Max continuous output powerVA240 290Nominal (L-L) voltage/range3V240 / 211 – 264Max continuous output currentA1.0 1.21Nominal frequencyHz60Extended frequency rangeHz50 – 68Max units per 20 A (L-L) branch circuit416 13Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed currentmA30Power factor setting1.0Grid-tied power factor (adjustable) 0.85 leading – 0.85 laggingPeak efficiency%97.5 97.6CEC weighted efficiency%97 97Night-time power consumptionmW60MECHANICAL DATAAmbient temperature range -40ºC to +60ºC (-40ºF to +140ºF)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (HxWxD) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesAcoustic noise at 1 m<60 dBAPollution degreePD3Enclosure Class II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure rating NEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8SP-DS-0002-01-EN-US-2021-10-191422 W MarionWay1/24/2025 1422 W MarionWay1/24/2025 1422 W MarionWay1/24/2025 TESLA.COM/ENERGYBackup Gateway 2POWERWALL660411149The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONSOperating Temperature–20°C to 50°C (–4°F to 122°F)Operating Humidity (RH)Up to 100%, condensingMaximum Elevation3000 m (9843 ft) EnvironmentIndoor and outdoor ratedEnclosure TypeNEMA 3RPERFORMANCE SPECIFICATIONSAC Voltage (Nominal)120/240VFeed-In TypeSplit PhaseGrid Frequency60 HzCurrent Rating200 AMaximum Input Short Circuit Current10 kA1Overcurrent Protection Device100-200A; Service Entrance Rated1Overvoltage CategoryCategory IVAC MeterRevenue accurate (+/– 0.2 %)Primary ConnectivityEthernet, Wi-FiSecondary ConnectivityCellular (3G, LTE/4G)2User InterfaceTesla AppOperating ModesSupport for solar self-consumption, time-based control, and backupBackup TransitionAutomatic disconnect for seamless backupModularitySupports up to 10 AC-coupled PowerwallsOptional Internal Panelboard200A 6-space / 12 circuit Eaton BR Circuit BreakersWarranty10 yearsCOMPLIANCE INFORMATIONCertificationsUL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205EmissionsFCC Part 15, ICES 003NA 2020-05-231 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes.2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength.MECHANICAL SPECIFICATIONSDimensions660 mm x 411 mm x 149 mm(26 in x 16 in x 6 in)Weight20.4 kg (45 lb)Mounting optionsWall mount, Semi-flush mount1422 W MarionWay1/24/2025 32023Powerwall 3 Datasheet Mechanical Specifications Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in) Weight 130 kg (287 lb) Mounting Options Floor or wall mount Powerwall 3 Technical Specifications Environmental Specifications Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IPX7 (Battery & Power Electronics) IPX5 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m <50 db(A) typical <62 db(A) maximum Compliance Information Certifications UL 1642, UL 1699B, UL 1741ȑȆȍȊȆˏ, UL 1741 SA, UL 1741 SB, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 1105 mm 193 mm m 42023Powerwall 3 Datasheet Electrical Specifications Model MCI-1 MCI-2 Nominal Input DC Current Rating (IMP)12 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Specifications Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X / IP65 NEMA 4X / IP65 RSD Module Performance Maximum Number of Devices per String 55 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Specifications Electrical Connections MC4 Connector MC4 Connector Housing Plastic Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip UL 3741 PV Hazard Control (and PVRSA) Compatibility The following categories of solar module meet the UL 3741 PVHCS listing when installed with Powerwall 3 and Solar Shutdown Devices. Tesla Solar Roof PV Hazard Control System: BIPV compliance document Tesla or Hanwha (Q.Peak Duo BLK or BLK-G6+) Modules certified for use with ZEP racking PV Hazard Control System: ZS PVHCS compliance document Other module and racking combinations PV Hazard Control System: Generic PV Array compliance document Compliance Information Certifications UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 7 Maximum System Voltage is limited by Powerwall to 600 V DC. 1422 W Marion Way1/24/2025 Powerwall 3Power Everything2023—Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 150 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production, fast and efficient installations, easy system expansion, and simple connection to any electrical service. 22023Powerwall 3 DatasheetSolar Technical SpecificationsMaximum Solar STC Input20 kWWithstand Voltage600 V DCPV DC Input Voltage Range60 — 550 V DCPV DC MPPT Voltage Range150 — 480 V DCMPPTs6Maximum Current per MPPT (Imp)13 A 5Maximum Short Circuit Current per MPPT (Isc)15 A 5Powerwall 3 Technical Specifications1 Typical solar shifting use case.2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power.3 Tested using CEC weighted efficiency methodology.4 Cellular connectivity subject to network service coverage and signal strength.5 Where the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A ISC.Battery Technical SpecificationsNominal Battery Energy13.5 kWh AC 2Maximum Continuous Discharge Power11.5 kWACMaximum Continuous Charge Power5 kW ACOutput Power Factor Rating0 - 1 (Grid Code configurable)Maximum Continuous Current48 ALoad Start Capability (1 s)150 A LRAPower ScalabilityUp to 4 Powerwall 3 units supportedSystem Technical SpecificationsModel Number1707000-xx-yNominal Grid Voltage120/240 V AC Grid ConfigurationSplit phaseGrid Frequency60 HzOvercurrent Protection DeviceConfigurable up to 60 ASolar to Battery to Grid Round Trip Efficiency89% 1,2Solar to Grid Efficiency97% 3Supported Islanding DevicesBackup Gateway 2, Backup SwitchConnectivityWi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4)Hardware InterfaceDry contact relay, Rapid Shutdown (RSD) certified switch and 2-pin connector, RS-485 for metersAC MeteringRevenue Grade (+/- 0.5%)ProtectionsIntegrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI), PV Rapid Shutdown (RSD) using Tesla Mid-Circuit InterruptersCustomer InterfaceTesla Mobile AppWarranty10 years1422 W MarionWay1/24/2025