HomeMy WebLinkAbout1930 S Artesia St - 101121407 & 20184383 - Plan0 PV SYSTEM AS INDICATED July 30, 2024 BERTA J SIBRIAN 1930 S ARTESIA ST, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.40KW PV SYSTEM AC SIZE 4.07KW COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 6 7 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET RACKING CERTIFICATE ATTACHMENT DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V ROOF PLAN MODULE MAP RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV BERTA J SIBRIAN 11 1930 S ARTESIA ST, SANTA ANA, CA 92704 SSP Service Sub Panel COMPOSITION SHINGLE 1,775 SQFT 40836409 CITY OF SANTA ANA WIRE SIZE CALCULATIONS INVERTER MAP D2 D3 D4 D5 D6 GROUNDING SPECSD7 ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 4.40 KW DC 4.40 KW 4.07 KW AC NEW UPGRADED ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS OPTIMIZER DATA SHEET 1 2 6,100 SQFT 1.1 SITE PLAN Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown BoxRSB Itron Meter IM UNIT INDEX CODE REFERENCES IRONRIDGE RACKING RAFTERS 2"X4" @ 24" O.C OCCUPANCY: R ONE STORY BUILDING 200A 200A (don't delete this note) AC DisconnectACD Visible Lockable Labeled DisconnectVLLD D8 BATTERY DATA SHEET LONGI SOLAR 400W LR5-54HABB-400M 1 SOLAR EDGE ENERGY HUB SE6000H-USSN 1 SOLAREDGE BAT-10K1PS0B-01 ENERGY BANK 10KWH D9 D10 BATTERY INSTALLATION MANUAL BATTERY MOUNTING DETAILS **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. ** Bldg#: 101121407 Elec#: 20184383 Approvals: Elec: M Smith 1930 S Artesia St 11/27/2024 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWROOF AREA CALCULATIONSFIRE SPRINKLERS - NOTOTAL ROOF AREA (SQ.FT.) - 3375SOLAR AREA (SQ.FT.) - 231% OF COVERED AREA - 6.8%PHOTOVOLTAIC SYSTEMFROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVERTHE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.40 KW DCROOF PLAN36'' Setback18'' Setback11Longi Solar 400W Modules (LR5-54HABB-400M)11Solar Edge S500 Power OptimizersNOTE: BATTERIES WILL BE INSTALLED A MIN 3FT AWAYFROM DOORS AND WINDOWS LEADING INSIDE THE HOUSE1Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSN (240V)N 0°S 180°E 90°W 270°SCALE1" = 10'MSPINVACDS A R T E S I A S TSolar Array 18 Longi Solar 400W8 S500 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S500 OptimizersTilt: 16 DegAzimuth: 115 DegSolarEdge Energy Bank BatteryJ/BDCDPV 0.01930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSITE PLANN 0°S 180°E 90°W 270°SCALE1" = 15'MSPINVACD100'20'5'32'44'DrivewayPu b l i c S i d e w a l k Public Sidewalk S A R T E S I A S T S RAITT ST (E) M A I N H O U S EPROPERTY LINESolarEdge Energy Bank Battery15'60'10'(E) PATIO(E) PATIODCDPV 1.01930 S Artesia St11/27/2024 S 1.0PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSTRUCTURAL STAMPROOFPITCHROOFINGTYPEATTACHMENTTYPEFRAMINGTYPEFRAMINGSIZEPENETRATIONPATTERN16°RACKINGTYPEMAXPENETRATIONSPACINGROOFINGLAYERSWIND SPEED95 MPHSNOW LOAD0 PSFEXPOSURECLAG BOLTSMOUNTS AND MOUNTING HARDWARE WILL BESEALED WITH CHEM LINK SEALANT OR EQUIVALENT.MODULE WEIGHT (LBS)# OF MODULESTOTAL MODULE WEIGHT (LBS)RACK WEIGHT (LBS)TOTAL SYSTEM WEIGHT (LBS)# OF STANDOFFSLOADING PER STANDOFF (LBS)TOTAL MODULE AREA (SQ.FT.)LOADING (PSF)WEIGHT LOAD CALCULATIONINDEXROOF SHEATHED WITH 1/2" PLYWOOD AND UPPERSURFACE IS FACED WITH FELT PAPERTOTAL ROOF AREA (Sq. FT)% OF COVERED AREAPV MODULE MODEL #11Roof1 LayerComp ShingleIronridge XR10RafterStacked48"2"X4" @ 24" O.C3124ITEM NO.1DESCRIPTION234BOLT LAG 5/16 X 4.75"ASSY, FLASHINGASSY, CAPFOOTWASHER, EPDM BACKEDQty in Kit44445/16" X 4.75"Flash Foot 2MIN 2.5" EMBEDMENTRACKING RAILATTACHMENTROOF FRAMING2823133755461091767124.02.916.82''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar TieSOLAR MODULEROOFASCE 7-16Max 3.5'' ATTACHMENTLAYOUT49.6LR5-54HABB-400MOPTIMIZERS WEIGHT (LBS)48"24"1930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWITEMDESCRIPTIONQTY#PV MODULEMAIN SERVICE PANELMAIN SERVICE PANEL& UTILITY METERBUSBAR RATINGBREAKER RATING1ITEMDESCRIPTIONQTY#PVC JUNCTION BOX4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 311143146MAINSERVICEPANEL120/240V1P,3W2EXISTINGGROUNDING SYSTEMUTILITY2360AAC DISCONNECTNON FUSED AC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 120/240V16NEW UPGRADEDNEW2133200A200A200AFOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3String: (11) Modules, (11) OptimizersSINGLE LINEDIAGRAM7(2)#10 AWG (10-12 AWG), 600V insulated(1)#24 AWG (16-24 AWG), 600V insulated or CAT61" EMT TYPE ConduitBATTERY17EXTERIOR KNIFE SWITCH TYPE DISCONNECTINSTALL 2P40A CB(PV) ATOPPOSITE ENDOF BUS FROMMAIN FEEDER CB(N)200A11LONGI SOLAR 400WLR5-54HABB-400MVoc = 37.05VVmp = 30.94VIsc = 13.72AImp = 12.93ASOLAREDGE POWER OPTIMIZERRATED DC INPUT POWERMAXIMUM INPUT VOLTAGEMPPT RANGEMAXIMUM SHORT CIRCUIT CURRENT (Isc)MAXIMUM OUTPUT CURRENTOPTIMIZER WEIGHTMAXIMUM POWER PER STRING5S500500W60 Vdc8 to 60 Vdc15.0 Adc15 Adc1.5 Lbs11POWER OPTIMIZER5700WINVERTERPEAK PWR TRACKING VOLTAGEINVERTER EFFICIENCYENCLOSURE :MAXIMUM INPUT CURRENTMAXIMUM OUTPUT CURRENTMAXIMUM INPUT POWERMAXIMUM OUTPUT POWER41380 V99.0 %NEMA 3R16.5 A25.0 A12,000 W6,000 WSOLAREDGE ENERGY HUB SE6000H-USSN (240V)BATTERY SYSTEMSSOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P8DC DISCONNECT18NON FUSED DC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 600V30AE 1.01930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWE 1.1FROM PV MODULES TO JBOXFROM JBOX TO INVERTER(2)1(1) #6 AWG BARE CU EGC,2 #10 AWG CU EGC,(3)3(1) #10 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A)OUTPUT CALCULATIONSPV SYSTEM MAX DC OUTPUTPV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A)1.251.251.250.91(2)(1) Pmax (PTC Rating)1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOFADJST. FACTOR (1 thru 3 WIRES)1.0FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS3/4'' EMT TYPE CONDUIT1'' EMT TYPE CONDUITMAIN SERVICE PANEL RATINGBUSBAR RATINGMAIN BREAKERPV BACKFEED BREAKER SIZE120% RULE:MAX ALLOWED FEED40A*/*1.25*1.2511400 38018.1/ /18.10.581.031.2#10 AWG THWN-2WIRE CHARTWIRE CHART *11400 4.40 KW* *11373.70.994.07 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT200A200A240A200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAXFROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING11#10 AWG PV-WIREWIRE SIZECALCULATIONS11400LR5-54HABB-400M400 W373.7 W25.0380199.0 %25.0 * 1.25 / 0.9134.4 #8 AWG THWN-2SOLAR EDGE SE6000H-USSN25.0 * 1.2531.31930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWJB BOXWARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)Inverter / PV LoadWARNINGTHE DISCONNECTION OF THEGROUNDING CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTCEC 690.31(E)CEC 690.54AC DisconnectCEC 690.54WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)PM METERMain/Sub PanelCEC 690.54CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59CEC 690.15 (B) & CEC 690.33(D)(2)CEC 690.13(B)SINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUIT!CEC 710.15(C)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)CEC 705.12 (B)(3)(2)LABELING REQUIREMENTS FOR ARTICLE 690CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whetherin the open (off) or closed (on) position and be permanently marked “PV SYSTEMDISCONNECT” or equivalent. Additional markings shall be permitted based uponthe specific system configuration.CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shallsimultaneously disconnect the PV system conductors that are not solidly groundedfrom all conductors of other wiring systems. The PV system disconnecting means orits remote operating device or the enclosure providing access to the disconnectingmeans shall be capable of being locked in accordance with 110.25.CEC 690.15(B) An isolating device shall not be required to have an interruptingrating. Where an isolating device is not rated for interrupting the circuit current, it shallbe marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." Anisolating device shall not be required to simultaneously disconnect all current-carryingconductors of a circuit.CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at alltermination, connection, and splice points by color coding, marking tape, tagging, orother approved means.CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiringmethods and enclosures that contain PV system dc circuit conductors shall be marked with thewording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means ofpermanently affixed labels or other approved permanent marking.CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiringsystem that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing betweenlabels or markings, or between a label and a marking, shall not be more than 3 m (10 ft).Labels required in this section shall be suitable for the environment where they are installed.CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with apermanent, legible warning notice indicating that the disconnection of the groundedconductor(s) may result in overvoltage on the equipment.CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of atool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”.CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors,and inverters shall be considered as internal components of an ac module or ac modulesystem.CEC 690.53 A permanent readily visible label indicating the highestmaximum dc voltage in a PV system, calculated in accordance with 690.7,shall be provided by the installer.CEC 690.54 All interactive system(s) points of interconnection with othersources shall be marked at an accessible location at the disconnectingmeans as a power source and with the rated ac output current and thenominal operating ac voltage.CEC 690.55 The PV system output circuit conductors shall be marked toindicate polarity where connected to energy storage systems.CEC 690.56(A) Plaques or directories shall be installed in accordance with705.10.CEC 690.56(C)(2) A rapid shutdown switch shall have a label located onor no more than 1 meter (3 ft) from the switch.CEC 690.59 PV systems connected to other sources shall be installed inaccordance with Parts I and II of Article 705 and Article 712.SOLAR ELECTRICPV PANELSSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH ON THE"OFF" POSITION TOSHUTDOWN PV SYSTEMAND REDUCESHOCK HAZARDIN ARRAYCFC 1205.4.1(1) & CEC 690.56(C)CEC 690.56(C)(2)CEC 690.31(D)(2)CEC 690.31(D)(2)CONDUIT RATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTWARNINGRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTWARNINGCAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDWARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.WARNINGDO NOT DISCONNECTUNDER LOADRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMWARNING: PHOTOVOLTAICPOWER SOURCEWARNINGPHOTOVOLTAIC POWER SOURCEDO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOWFOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUTDOWN THE ARRAY AND THE CONDUCTORS LEAVINGTHE ARRAY, A LABEL SHALL BE PROVIDED. THEFIRST TWO LINES OF THE LABEL SHALL BEUPPERCASE CHARACTERS WITH A MINIMUMHEIGHT OF 3/8 INCH (10 MM) IN BLACK ON AYELLOW BACKGROUND. THE REMAININGCHARACTERS SHALL BE UPPERCASE WITH AMINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ONA WHITE BACKGROUND. [CFC 1205.4.1(1)]240 Vac240 Vac240 VacCEC 690.13(B)AC DISCONNECTPHOTOVOLTAIC25.0 A25.0 A25.0 A CEC 705.10CAUTIONMULTIPLE SOURCES OF POWER CEC 705.10CAUTIONMULTIPLE SOURCES OF POWERCEC 690.53MAXIMUM SYSTEM VOLTAGERATED SHORT CIRCUIT CURRENTN/AMAX RATED AC OPERATING VOLTAGEN/ARATED AC OPERATING VOLTAGEMAX RATED AC OPERATING CURRENTRATED AC OPERATING CURRENTN/AN/AN/AN/ACODE REQUIREDSIGNAGECAUTIONN 0°S 180°E 90°W 270°MULTIPLE SOURCES OF POWERCEC 705.10 & CEC 710.10Permanent directory or plaque providing location of service disconnecting means andphotovoltaic system disconnecting means, if not located at the same location. (Plaques shallbe metal or plastic, with engraved or machine printed letters, or electro-photo plating, in acontrasting color to the plaque. Plaques shall be permanently attached to the equipment or in therequired location using an approved method that is suitable to withstand the environment to which itis exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesionrequirements of Underwriters Laboratories marking and labeling system 969(UL969).Plaques will have red background & white lettering.CEC 480.7(B)EMERGENCY DISCONNECTS A R T E S I A S T INVERTERAC DISCONNECTMAIN SERVICE PANELESS DISCONNECTDC DISCONNECTPV 2.01930 S Artesia St11/27/2024 PV 2.1PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KW[FOR INSTALLER USE ONLY]PHOTOVOLTAIC SYSTEM4.40 KW DCMODULE MAP11 Longi Solar 400W Modules (LR5-54HABB-400M)11Solar Edge S500 Power Optimizers1Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNSolar Array 18 Longi Solar 400W8 S500 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S500 OptimizersTilt: 16 DegAzimuth: 115 Deg1930 S Artesia St11/27/2024 PV 3.0PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWINVERTERPHOTOVOLTAIC SYSTEM4.40 KW DC[FOR INSTALLER USE ONLY]INVERTER MAP11Longi Solar 400W Modules (LR5-54HABB-400M)11Solar Edge S500 Power Optimizers1Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNSolar Array 18 Longi Solar 400W8 S500 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S500 OptimizersTilt: 16 DegAzimuth: 115 Deg1930 S Artesia St11/27/2024 PV 3.1PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWMODULEDATA SHEET1930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 4.0INVERTERDATA SHEET1930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 5.1ATTACHMENTDATA SHEET1930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 5.0RACKINGDATA SHEET1930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 6.0GROUNDINGSPECS1930 S Artesia St11/27/2024 PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 6.1BATTERYDATA SHEET1930 S Artesia St11/27/2024 1930 S. ARTESIA ST. SANTA ANA, CA 92704 SIBRIAN, BERTA Design Criteria 1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16 2 - Wind: 95 MPH, Exposure: C 3 - Wood Species: DF-L No. 2 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. 1-844-PV ELITE | info@yoursolarplans.com 3000 E. Birch Street Suite 201 | Brea CA 92821 7/30/2024 Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: Job: 1930 S Artesia St 11/27/2024 1930 S Artesia St 11/27/2024 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope =16 ° Roof Shape Hip Tributary Width s =4.00 ft Tributary Length l =2.82 ft Effective Area Ae =11.30 ft2 Height of Structure h =15 ft Wind Speed V =95 mph Exposure Category C Building Width B =30 ft Building Length L =50 ft Zone Width a =3ft Elevation Height zg =49 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.64 psf Solar Array Pressure Equalization a =0.79 Array Edge Factor E =1.50 Zone GCp p = qz(GCp)(E)(a) 3 2.59 -51.38 3r - - 3e - - 2-- 2r 2.38 -47.27 2e 2.59 -51.38 2n - - 1 1.80 -35.69 1' - - 1930 S Artesia St 11/27/2024 LAG SCREW ANALYSIS Loads Wind Pressures qz =-51.38 psf Solar Panel Load QD =3 psf Panel Length l =5.650 ft Panel Width b 3.7205 ft Attachment Spacing s =4ft Portrait Tributary Area At =11.30 ft2 Wind Load PW = qz * At =-581 lbs Dead Load PD = QD * At =33.898 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-328 lbs Landscape Tributary Area At = b * s =7.4409 ft2 Wind Load PW = qz * At =-382 lbs Dead Load PD = QD * At =22.323 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-216 lbs Lag Screw Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch) Diameter of Lag Screw D =5/16 in Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in Depth of Embedment lp =2.50 in Total Nominal Withdrawal Value W = W * l p =665 lbs Load Duration Factor CD =1.6 Withdrawal Design Value W' = W * C D =1064 lbs Demand Capacity Ratio DCR = Pa / W'=0.31 < 1 OK 1930 S Artesia St 11/27/2024 ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check Roof Slope =16 ° Roof Shape Hip Tributary Width s =2.00 ft Tributary Length L =13.50 ft Effective Area A = L ( MAX [ s , L/3] )=61 ft2 Height of Structure h =15 ft Wind Speed V =95 mph Exposure Category C Building Width B =30 ft Building Length L =50 ft Zone Width a =3ft Elevation Height zg =49 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.64 psf Internal Pressure Coefficient (GCpi)=-0.18 Zone GCp p = qz [(GCp) - (Gcpi)] 3 2.28 -40.93 3r - - 3e - - 2-- 2r 1.78 -32.61 2e 2.28 -40.93 2n - - 1 1.39 -26.17 1' - - 1930 S Artesia St 11/27/2024 Beam/ Top Chord Check Lumber: Moment Demand # of Attachment per Rafter NA =Span :Orientation Lenght (ft) : Dead Load Roof Material:QD =psf Live Load QLr =psf Wind Load p = psf Snow Load QS =psf Rafter Spacing s = in Wind Load, Portrait Portrait UL = Wind Load, Landscape Landscape UW = Linear Dead Load wd =plf Live Load wLr = plf Start ft Start ft End ft End ft Snow Load ws = plf Start ft Start ft End ft End ft Ma, Moment D lb-ft D+Lr lb-ft D+S lb-ft 0.6D+0.6W lb-ft D+0.45W+0.75Lr lb-ft D+0.45W+0.75S lb-ft Moment Capacity Framing Member Size Lumber Grade : DF-L No. 2 CM = 1 Ct = 1 Cr=CF = fb =psi Cfu =Ci = Breadth b = in Depth d = in Section Modulus Sx = bd 2 / 6 =in3 Bending Stress Capacity Fb = CM * Ct * Cr * C F * fb =psi Table 4.3.1 NDS 2015 Deflection Limit E = ksi I =in4 Transient Deflection in Transient Deflection Allowed > [OKAY] Total Deflection in Total Deflection Allowed > [OKAY] -40.93 DF-L No. 2 4 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs) Portrait 1 2.2 33.9 -462 0.0 6.4 33.9 -462 -462 0.0 4 12.1 33.9 -462 0.0 0.0 8.00 4.50 0.00 0.00 1.00 Portrait 3 7.9 33.9 10.00 1234Eave 2 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0 0.0 Portrait 0 0.0 0.0 0 0.0 20 40 0.0 0.0 0.0 0.0 0 0.0 Portrait 0 0.022.323 -305 0 0 0.0 0 1.5 0 0 0.0 Portrait 1.5 0.0Portrait0 0.0 0.0 AT (ft2) 11.299 7.4409 pd (lbs) 33.898 -462 pw (lbs) ps (lbs) 0 12.80 2x4 1.15 1.5 13.50 12.80 13.50 900 1.50 3.50 169 174 169 367 192 192 DCR 0.9 1397 psi D 662 psi 0.47 3.06 1553 CD Fb' = CD * Fb ASD Load Ma / Sx 1.15 1785 psi D+S 662 psi 0.37 OKAY OKAY 1.25 1941 psi D+Lr 684 psi 0.35 OKAY 1.6 2484 psi 0.364 263 120 1600 5.36 0.6D+0.6W 1437 psi 0.58 OKAY 1.0 1 20 0.00 24 Comp 0.330 291 180 1.6 2484 psi D+0.45W+0.75S 751 psi 0.30 OKAY 1.6 2484 psi D+0.45W+0.75Lr 751 psi 0.30 OKAY 𝑴𝒙ൌ𝑹𝒊ሺ𝒙െ𝑳𝒊ሻെ𝑷𝒋𝒙െ𝒍𝒋െ 𝒘𝒅𝒙𝟐 𝟐 ‐400.0 ‐200.0 0.0 200.0 400.0 600.0 0.000 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000 1930 S Artesia St 11/27/2024 EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model Longi Panel Weight W panel = 49.6 lbs Number of Panels NPV =11 Total PV System Weight W PV = W panel * NPV =545.6 lbs Existing Roof Weight Roof Weight QD =10.0 psf Building Length Lbuild =50 ft Building Width W build =30 ft Roof Area Abuild =1500 ft2 Building Perimeter Pbuild =160 ft Wall Height ht =8ft Wall weight Qwall =15 psf Interior wall weight Qint =10 psf Roof Load W floor = Abuild * QD =15000 lbs Wall LoadW wall = ht /2 * Qwall * Pbuild + Abuild * Qint /2 =17100 lbs Total Story Weight W build = W floor + W wall =32100 lbs Percentage Weight Increase WPV / Wbuild = 1.70% < 10% OKAY 1930 S Artesia St 11/27/2024 •• ••• •• CLEAN ENERGY SOLUTIONS To whom it may concern, Clean Energy Solutions 417 W. Allen Ave Suite #105 San Dimas CA, 91773 800)994-1134 This letter authorizes Bernard Albosta to pull permits/ business license on behalf of Clean Energy Solutions. If you have any question, please call us at 800) 994-1134 Sincerely, David Gomez CEO A notary public or other officer comple�ng this cerlificate verifies only the Identity of the individual who signed lhe document 10 which lhis certificate is attached, and nol the lruthlulness accuracy, or validily of lhat document. State of California County of / f)S �lc.J Subscribe�nd sworn to (or affirmed)beore me on thisl_day of ?:(� ,20 1-!J by � Q-y\<k (-,ol\Jv+;. proved to me on the basis of satisfactory evidence to be the person( who app ared before me. Signature (Nolary Seat) ' @ ANDRE ROBINSONI , r. COMM # 2433203 � :;; NOTARY PUBLIC· CAUFORNIA !'? I LOS ANGELES COUNTY Ilily Com! Ell)ltS JANUARY ll. 2027 q • 0 1930 S Artesia St 11/27/2024 1930 S Artesia St11/27/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1930 S Artesia St Santa Ana, CA 92704 Bernard Albosta 998787 Bernard Albosta mluna@cleanenrgysolar.orgPhone Number: 8009941134 10/4/24 1930 S Artesia St 11/27/2024 0 PV SYSTEM AS INDICATED November 12, 2024 BERTA J SIBRIAN 1930 S ARTESIA ST, SANTA ANA, CA 92704 Clean Energy Solutions Inc. Address: 1055 West 7th Street 33rd Floor, Los Angeles, CA 90017 Phone Number: (800) 994 1134 Lic# 998787 Class C-10 CONTRACTOR Designed By: Intersolar CAD www.intersolarcad.com PV SYSTEM DC SIZE 4.40KW PV SYSTEM AC SIZE 4.07KW COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 6 7 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET RACKING CERTIFICATE ATTACHMENT DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V ROOF PLAN MODULE MAP RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV BERTA J SIBRIAN 11 1930 S ARTESIA ST, SANTA ANA, CA 92704 SSP Service Sub Panel COMPOSITION SHINGLE 1,775 SQFT 40836409 CITY OF SANTA ANA WIRE SIZE CALCULATIONS INVERTER MAP D2 D3 D4 D5 D6 GROUNDING SPECSD7 ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 4.40 KW DC 4.40 KW 4.07 KW AC NEW UPGRADED ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS OPTIMIZER DATA SHEET 1 2 6,100 SQFT 1.1 SITE PLAN Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown ControllerRSC Rapid Shutdown BoxRSB Itron MeterIM UNIT INDEX CODE REFERENCES IRONRIDGE RACKING RAFTERS 2"X4" @ 24" O.C OCCUPANCY: R ONE STORY BUILDING 200A 200A (don't delete this note) AC DisconnectACD Visible Lockable Labeled DisconnectVLLD D8 BATTERY DATA SHEET LONGI SOLAR 400W LR5-54HABB-400M SOLAR EDGE SE5700H-USMNUBL15 (240V) 1 SOLAREDGE BAT-10K1PS0B-01 ENERGY BANK 10KWH D9 D10 BATTERY INSTALLATION MANUAL BATTERY MOUNTING DETAILS 1 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101122088 Elec#: 20184808 Revision to: Bldg#: 101121407 Elec#: 20184383 Approvals: Elec: M Smith 1930 S Artesia St 1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWROOF AREA CALCULATIONSFIRE SPRINKLERS - NOTOTAL ROOF AREA (SQ.FT.) - 3375SOLAR AREA (SQ.FT.) - 231% OF COVERED AREA - 6.8%PHOTOVOLTAIC SYSTEMFROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVERTHE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.40 KW DCROOF PLAN36'' Setback18'' Setback11Longi Solar 400W Modules (LR5-54HABB-400M)Solar Edge S440 Power Optimizers11NOTE: BATTERIES WILL BE INSTALLED A MIN 3FT AWAYFROM DOORS AND WINDOWS LEADING INSIDE THE HOUSE1Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V)N 0°S 180°E 90°W 270°SCALE1" = 10'MSPINVACDS A R T E S I A S TSolar Array 18 Longi Solar 400W8 S440 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S440 OptimizersTilt: 16 DegAzimuth: 115 DegSolarEdge Energy Bank BatteryJ/BDCDPV 0.01930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSITE PLANN 0°S 180°E 90°W 270°SCALE1" = 15'MSPINVACD100'20'5'32'44'DrivewayPu b l i c S i d e w a l k Public Sidewalk S A R T E S I A S T S RAITT ST (E) M A I N H O U S EPROPERTY LINESolarEdge Energy Bank Battery15'60'10'(E) PATIO(E) PATIODCDPV 1.01930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSTRUCTURAL STAMPROOFPITCHROOFINGTYPEATTACHMENTTYPEFRAMINGTYPEFRAMINGSIZEPENETRATIONPATTERN16°RACKINGTYPEMAXPENETRATIONSPACINGROOFINGLAYERSWIND SPEED95 MPHSNOW LOAD0 PSFEXPOSURECLAG BOLTSMOUNTS AND MOUNTING HARDWARE WILL BESEALED WITH CHEM LINK SEALANT OR EQUIVALENT.MODULE WEIGHT (LBS)# OF MODULESTOTAL MODULE WEIGHT (LBS)RACK WEIGHT (LBS)TOTAL SYSTEM WEIGHT (LBS)# OF STANDOFFSLOADING PER STANDOFF (LBS)TOTAL MODULE AREA (SQ.FT.)LOADING (PSF)WEIGHT LOAD CALCULATIONINDEXROOF SHEATHED WITH 1/2" PLYWOOD AND UPPERSURFACE IS FACED WITH FELT PAPERTOTAL ROOF AREA (Sq. FT)% OF COVERED AREAPV MODULE MODEL #11Roof1 LayerComp ShingleIronridge XR10RafterStacked48"2"X4" @ 24" O.C3124ITEM NO.1DESCRIPTION234BOLT LAG 5/16 X 4.75"ASSY, FLASHINGASSY, CAPFOOTWASHER, EPDM BACKEDQty in Kit44445/16" X 4.75"Flash Foot 2MIN 2.5" EMBEDMENTRACKING RAILATTACHMENTROOF FRAMING2823133755461091767124.02.916.82''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar TieSOLAR MODULEROOFASCE 7-16Max 3.5'' ATTACHMENTLAYOUT49.6LR5-54HABB-400MOPTIMIZERS WEIGHT (LBS)48"24"S 1.01930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWITEMDESCRIPTIONQTY#PV MODULEMAIN SERVICE PANELMAIN SERVICE PANEL& UTILITY METERBUSBAR RATINGBREAKER RATING1ITEMDESCRIPTIONQTY#PVC JUNCTION BOX4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 311143146MAINSERVICEPANEL120/240V1P,3W2EXISTINGGROUNDING SYSTEMUTILITY2360AAC DISCONNECTNON FUSED AC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 120/240V16NEW UPGRADEDNEW2133200A200A200AFOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3String: (11) Modules, (11) OptimizersSINGLE LINEDIAGRAM7(2)#10 AWG (10-12 AWG), 600V insulated(1)#24 AWG (16-24 AWG), 600V insulated or CAT61" EMT TYPE ConduitBATTERY17EXTERIOR KNIFE SWITCH TYPE DISCONNECTINSTALL 2P30A CB(PV) ATOPPOSITE ENDOF BUS FROMMAIN FEEDER CB(N)200A11LONGI SOLAR 400WLR5-54HABB-400MVoc = 37.05VVmp = 30.94VIsc = 13.72AImp = 12.93ASOLAREDGE POWER OPTIMIZERRATED DC INPUT POWERMAXIMUM INPUT VOLTAGEMPPT RANGEMAXIMUM SHORT CIRCUIT CURRENT (Isc)MAXIMUM OUTPUT CURRENTOPTIMIZER WEIGHTMAXIMUM POWER PER STRING5S440440W60 Vdc8 to 60 Vdc14.5 Adc15 Adc1.5 Lbs11POWER OPTIMIZER380 V99.0 %NEMA 413.5 A24.0 A11,520 W5,760 WINVERTERPEAK PWR TRACKING VOLTAGEMAXIMUM INPUT CURRENTMAXIMUM OUTPUT CURRENTMAXIMUM INPUT POWERMAXIMUM CONTINUOUS OUTPUT POWER45700W1SOLAREDGE SE5700H-USMNUBL15 (240V)ENCLOSURE:INVERTER EFFICIENCYBATTERY SYSTEMSSOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P8DC DISCONNECT18NON FUSED DC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 600V30AE 1.01930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWFROM PV MODULES TO JBOXFROM JBOX TO INVERTER(2)1(1) #6 AWG BARE CU EGC,2 #10 AWG CU EGC,(3)3(1) #10 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A)OUTPUT CALCULATIONSPV SYSTEM MAX DC OUTPUTPV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A)1.251.251.250.91(2)(1) Pmax (PTC Rating)1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOFADJST. FACTOR (1 thru 3 WIRES)1.0FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS3/4'' EMT TYPE CONDUIT1'' EMT TYPE CONDUITMAIN SERVICE PANEL RATINGBUSBAR RATINGMAIN BREAKERPV BACKFEED BREAKER SIZE120% RULE:MAX ALLOWED FEED30A*/*1.25*1.251140038018.1//18.10.581.031.2#10 AWG THWN-2WIRE CHARTWIRE CHART *11400 4.40 KW**11373.70.994.07 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT200A200A240A200A ''MB'' + 30A "SOLAR" = 230A ≤ 240A MAXFROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING11#10 AWG PV-WIREWIRE SIZECALCULATIONS11400LR5-54HABB-400M400 W373.7 W38099 %1 #10 AWG THWN-224.0 * 1.25 / 0.9124.033.0 SOLAR EDGE SE5700H-USMNUBL15 (240V)24.0 * 1.2530.0E 1.11930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWJB BOXWARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)Inverter / PV LoadWARNINGTHE DISCONNECTION OF THEGROUNDING CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTCEC 690.31(E)CEC 690.54AC DisconnectCEC 690.54WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)PM METERMain/Sub PanelCEC 690.54CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59CEC 690.15 (B) & CEC 690.33(D)(2)CEC 690.13(B)SINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUIT!CEC 710.15(C)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)CEC 705.12 (B)(3)(2)LABELING REQUIREMENTS FOR ARTICLE 690CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whetherin the open (off) or closed (on) position and be permanently marked “PV SYSTEMDISCONNECT” or equivalent. Additional markings shall be permitted based uponthe specific system configuration.CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shallsimultaneously disconnect the PV system conductors that are not solidly groundedfrom all conductors of other wiring systems. The PV system disconnecting means orits remote operating device or the enclosure providing access to the disconnectingmeans shall be capable of being locked in accordance with 110.25.CEC 690.15(B) An isolating device shall not be required to have an interruptingrating. Where an isolating device is not rated for interrupting the circuit current, it shallbe marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." Anisolating device shall not be required to simultaneously disconnect all current-carryingconductors of a circuit.CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at alltermination, connection, and splice points by color coding, marking tape, tagging, orother approved means.CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiringmethods and enclosures that contain PV system dc circuit conductors shall be marked with thewording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means ofpermanently affixed labels or other approved permanent marking.CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiringsystem that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing betweenlabels or markings, or between a label and a marking, shall not be more than 3 m (10 ft).Labels required in this section shall be suitable for the environment where they are installed.CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with apermanent, legible warning notice indicating that the disconnection of the groundedconductor(s) may result in overvoltage on the equipment.CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of atool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”.CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors,and inverters shall be considered as internal components of an ac module or ac modulesystem.CEC 690.53 A permanent readily visible label indicating the highestmaximum dc voltage in a PV system, calculated in accordance with 690.7,shall be provided by the installer.CEC 690.54 All interactive system(s) points of interconnection with othersources shall be marked at an accessible location at the disconnectingmeans as a power source and with the rated ac output current and thenominal operating ac voltage.CEC 690.55 The PV system output circuit conductors shall be marked toindicate polarity where connected to energy storage systems.CEC 690.56(A) Plaques or directories shall be installed in accordance with705.10.CEC 690.56(C)(2) A rapid shutdown switch shall have a label located onor no more than 1 meter (3 ft) from the switch.CEC 690.59 PV systems connected to other sources shall be installed inaccordance with Parts I and II of Article 705 and Article 712.SOLAR ELECTRICPV PANELSSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH ON THE"OFF" POSITION TOSHUTDOWN PV SYSTEMAND REDUCESHOCK HAZARDIN ARRAYCFC 1205.4.1(1) & CEC 690.56(C)CEC 690.56(C)(2)CEC 690.31(D)(2)CEC 690.31(D)(2)CONDUIT RATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTWARNINGRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTWARNINGCAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDWARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.WARNINGDO NOT DISCONNECTUNDER LOADRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMWARNING: PHOTOVOLTAICPOWER SOURCEWARNINGPHOTOVOLTAIC POWER SOURCEDO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOWFOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUTDOWN THE ARRAY AND THE CONDUCTORS LEAVINGTHE ARRAY, A LABEL SHALL BE PROVIDED. THEFIRST TWO LINES OF THE LABEL SHALL BEUPPERCASE CHARACTERS WITH A MINIMUMHEIGHT OF 3/8 INCH (10 MM) IN BLACK ON AYELLOW BACKGROUND. THE REMAININGCHARACTERS SHALL BE UPPERCASE WITH AMINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ONA WHITE BACKGROUND. [CFC 1205.4.1(1)]240 Vac240 Vac240 VacCEC 690.13(B)AC DISCONNECTPHOTOVOLTAIC25.0 A25.0 A25.0 A CEC 705.10CAUTIONMULTIPLE SOURCES OF POWER CEC 705.10CAUTIONMULTIPLE SOURCES OF POWERCEC 690.53MAXIMUM SYSTEM VOLTAGERATED SHORT CIRCUIT CURRENTN/AMAX RATED AC OPERATING VOLTAGEN/ARATED AC OPERATING VOLTAGEMAX RATED AC OPERATING CURRENTRATED AC OPERATING CURRENTN/AN/AN/AN/ACODE REQUIREDSIGNAGECAUTIONN 0°S 180°E 90°W 270°MULTIPLE SOURCES OF POWERCEC 705.10 & CEC 710.10Permanent directory or plaque providing location of service disconnecting means andphotovoltaic system disconnecting means, if not located at the same location. (Plaques shallbe metal or plastic, with engraved or machine printed letters, or electro-photo plating, in acontrasting color to the plaque. Plaques shall be permanently attached to the equipment or in therequired location using an approved method that is suitable to withstand the environment to which itis exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesionrequirements of Underwriters Laboratories marking and labeling system 969(UL969).Plaques will have red background & white lettering.CEC 480.7(B)EMERGENCY DISCONNECTS A R T E S I A S T INVERTERAC DISCONNECTMAIN SERVICE PANELESS DISCONNECTDC DISCONNECTPV 2.01930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KW[FOR INSTALLER USE ONLY]PHOTOVOLTAIC SYSTEM4.40 KW DCMODULE MAP11Longi Solar 400W Modules (LR5-54HABB-400M)Solar Edge S440 Power Optimizers111Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V)Solar Array 18 Longi Solar 400W8 S440 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S440 OptimizersTilt: 16 DegAzimuth: 115 DegPV 2.11930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWINVERTERPHOTOVOLTAIC SYSTEM4.40 KW DC[FOR INSTALLER USE ONLY]INVERTER MAP11Longi Solar 400W Modules (LR5-54HABB-400M)Solar Edge S440 Power Optimizers111Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V)Solar Array 18 Longi Solar 400W8 S440 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S440 OptimizersTilt: 16 DegAzimuth: 115 DegPV 3.01930 S Artesia St1/23/2025 PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWINVERTERDATA SHEETPV 4.01930 S Artesia St1/23/2025 1930 S Artesia St1/23/2025 --- - - --- - - - - 1930 S Artesia St Santa Ana, CA 92704 101121407 11/25/2024 $460.36 Smith, Mark Bernard Albosta Clean Energy Solutions web_issue 800 994-1134 Melissa Luna mluna@cleanenergysolar.org 800 994-1134 The equipment location has been changed. The power optimizer has been changed. The inverter type has been changed. The PV breaker size has been changed. 1930 S Artesia St 1/23/2025