PV SYSTEM
AS INDICATED
July 30, 2024
BERTA J SIBRIAN
1930 S ARTESIA ST,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Intersolar CAD
www.intersolarcad.com
PV SYSTEM DC SIZE 4.40KW
PV SYSTEM AC SIZE 4.07KW
COVER PAGE
1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE
COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY
2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED
3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED
4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER.
5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING
COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED.
6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY
AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL
INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY.
7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE
COORDINATED WITH OTHER TRADES.
8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS
RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT.
9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE
WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE.
10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE
SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS.
OWNER
SCOPE
PROJECT
ADDRESS
PROJECT DATA GENERAL NOTES VICINITY MAP
SHEET INDEX
0 COVER PAGE
PHOTOVOLTAIC NOTES
SATELLITE VIEW
BUILDING
INFORMATION:
SINGLE LINE DIAGRAM
CODE REQUIRED SIGNAGE
3
4
ATTACHMENT LAYOUT5
6
7
INVERTER DATA SHEET
D1 MODULE DATA SHEET
RACKING DATA SHEET
RACKING CERTIFICATE
ATTACHMENT DATA SHEET
ELECTRICAL
INFORMATION
MAIN SERVICE PANEL
BUSBAR RATING
MAIN SERVICE
BREAKER RATING
1ɸ, 3W, 120/240V
ROOF PLAN
MODULE MAP
RACKING
INFORMATION
Main Service Panel
Solar Module
Micro Inverter /
Optimizer
EMT / FMT / PVC
/ RMC type conduit/
Romex NM Cable/
FNMT (Fluid non-metalic tube)
36'' SetbackInverter
Utility Meter
Production Meter
PV Load Center
IQ Combiner Box
Junction Box
Sunpower PV Supervisor
18'' Setback
EV Outlet
CONSTRUCTION TYPE: V-B
ROOF
TYPE
AHJ
APN
LOT AREA
LIVING AREA
MSP
UM
PM
INV
PV
PVS6
IQ
J/B
EV
BERTA J SIBRIAN
11
1930 S ARTESIA ST,
SANTA ANA, CA 92704
SSP Service Sub Panel
COMPOSITION SHINGLE
1,775 SQFT
40836409
CITY OF SANTA ANA
WIRE SIZE CALCULATIONS
INVERTER MAP
D2
D3
D4
D5
D6
GROUNDING SPECSD7
ROOF MOUNT INSTALLATION OF
DC PHOTOVOLTAIC SYSTEM
4.40 KW DC
4.40 KW
4.07 KW AC
NEW UPGRADED
ALL OTHER ORDINANCE ADOPTED BY THE
LOCAL GOVERNING AGENCIES
THE INSTALLATION OF SOLAR ARRAYS AND
PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY
WITH THE FOLLOWING CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
2022 CALIFORNIA HISTORICAL CODE
2022 CALIFORNIA EXISTING BUILDING CODE
2022 CALIFORNIA REFERENCED STANDARDS CODE
2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE
1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703.
2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS
3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED.
4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER
OUTAGE.
5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING
ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS.
6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE.
7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE
ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED.
8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION
9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED
10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT.
11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING
MEANS AS PER 230.82(6)
12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING
AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122
13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122.
14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS
OPTIMIZER DATA SHEET
1
2
6,100 SQFT 1.1 SITE PLAN
Battery BackupBB
Auto TransformerAT
Solar Edge Meter EnclosureSEM
Distribution PanelDP
Rapid Shutdown Controller RSC
Rapid Shutdown BoxRSB
Itron Meter IM
UNIT INDEX
CODE REFERENCES
IRONRIDGE RACKING
RAFTERS 2"X4" @ 24" O.C
OCCUPANCY: R
ONE STORY BUILDING
200A
200A
(don't delete this note)
AC DisconnectACD
Visible Lockable
Labeled DisconnectVLLD
D8 BATTERY DATA SHEET
LONGI SOLAR 400W
LR5-54HABB-400M
1 SOLAR EDGE ENERGY HUB SE6000H-USSN
1 SOLAREDGE BAT-10K1PS0B-01
ENERGY BANK 10KWH
D9
D10
BATTERY INSTALLATION MANUAL
BATTERY MOUNTING DETAILS
**The scope of the plans is for the
installation of the solar photovoltaic
system only and the approval is subject to
compliance with all applicable city and
state codes and regulations regarding
construction. The approval of the plans
does not constitute any certification of the
accuracy, completeness, or building
permit status of the existing buildings and
structures as shown. **
Bldg#: 101121407
Elec#: 20184383
Approvals:
Elec: M Smith
1930 S Artesia St
11/27/2024
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWROOF AREA CALCULATIONSFIRE SPRINKLERS - NOTOTAL ROOF AREA (SQ.FT.) - 3375SOLAR AREA (SQ.FT.) - 231% OF COVERED AREA - 6.8%PHOTOVOLTAIC SYSTEMFROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVERTHE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.40 KW DCROOF PLAN36'' Setback18'' Setback11Longi Solar 400W Modules (LR5-54HABB-400M)11Solar Edge S500 Power OptimizersNOTE: BATTERIES WILL BE INSTALLED A MIN 3FT AWAYFROM DOORS AND WINDOWS LEADING INSIDE THE HOUSE1Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSN (240V)N 0°S 180°E 90°W 270°SCALE1" = 10'MSPINVACDS A
R
T
E
S
I
A
S
TSolar Array 18 Longi Solar 400W8 S500 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S500 OptimizersTilt: 16 DegAzimuth: 115 DegSolarEdge Energy Bank BatteryJ/BDCDPV 0.01930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSITE PLANN 0°S 180°E 90°W 270°SCALE1" = 15'MSPINVACD100'20'5'32'44'DrivewayPu
b
l
i
c
S
i
d
e
w
a
l
k
Public Sidewalk
S A
R
T
E
S
I
A
S
T
S RAITT ST
(E)
M
A
I
N
H
O
U
S
EPROPERTY LINESolarEdge Energy Bank Battery15'60'10'(E) PATIO(E) PATIODCDPV 1.01930 S Artesia St11/27/2024
S 1.0PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSTRUCTURAL STAMPROOFPITCHROOFINGTYPEATTACHMENTTYPEFRAMINGTYPEFRAMINGSIZEPENETRATIONPATTERN16°RACKINGTYPEMAXPENETRATIONSPACINGROOFINGLAYERSWIND SPEED95 MPHSNOW LOAD0 PSFEXPOSURECLAG BOLTSMOUNTS AND MOUNTING HARDWARE WILL BESEALED WITH CHEM LINK SEALANT OR EQUIVALENT.MODULE WEIGHT (LBS)# OF MODULESTOTAL MODULE WEIGHT (LBS)RACK WEIGHT (LBS)TOTAL SYSTEM WEIGHT (LBS)# OF STANDOFFSLOADING PER STANDOFF (LBS)TOTAL MODULE AREA (SQ.FT.)LOADING (PSF)WEIGHT LOAD CALCULATIONINDEXROOF SHEATHED WITH 1/2" PLYWOOD AND UPPERSURFACE IS FACED WITH FELT PAPERTOTAL ROOF AREA (Sq. FT)% OF COVERED AREAPV MODULE MODEL #11Roof1 LayerComp ShingleIronridge XR10RafterStacked48"2"X4" @ 24" O.C3124ITEM NO.1DESCRIPTION234BOLT LAG 5/16 X 4.75"ASSY, FLASHINGASSY, CAPFOOTWASHER, EPDM BACKEDQty in Kit44445/16" X 4.75"Flash Foot 2MIN 2.5" EMBEDMENTRACKING RAILATTACHMENTROOF FRAMING2823133755461091767124.02.916.82''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar TieSOLAR MODULEROOFASCE 7-16Max 3.5'' ATTACHMENTLAYOUT49.6LR5-54HABB-400MOPTIMIZERS WEIGHT (LBS)48"24"1930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWITEMDESCRIPTIONQTY#PV MODULEMAIN SERVICE PANELMAIN SERVICE PANEL& UTILITY METERBUSBAR RATINGBREAKER RATING1ITEMDESCRIPTIONQTY#PVC JUNCTION BOX4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 311143146MAINSERVICEPANEL120/240V1P,3W2EXISTINGGROUNDING SYSTEMUTILITY2360AAC DISCONNECTNON FUSED AC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 120/240V16NEW UPGRADEDNEW2133200A200A200AFOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3String: (11) Modules, (11) OptimizersSINGLE LINEDIAGRAM7(2)#10 AWG (10-12 AWG), 600V insulated(1)#24 AWG (16-24 AWG), 600V insulated or CAT61" EMT TYPE ConduitBATTERY17EXTERIOR KNIFE SWITCH TYPE DISCONNECTINSTALL 2P40A CB(PV) ATOPPOSITE ENDOF BUS FROMMAIN FEEDER CB(N)200A11LONGI SOLAR 400WLR5-54HABB-400MVoc = 37.05VVmp = 30.94VIsc = 13.72AImp = 12.93ASOLAREDGE POWER OPTIMIZERRATED DC INPUT POWERMAXIMUM INPUT VOLTAGEMPPT RANGEMAXIMUM SHORT CIRCUIT CURRENT (Isc)MAXIMUM OUTPUT CURRENTOPTIMIZER WEIGHTMAXIMUM POWER PER STRING5S500500W60 Vdc8 to 60 Vdc15.0 Adc15 Adc1.5 Lbs11POWER OPTIMIZER5700WINVERTERPEAK PWR TRACKING VOLTAGEINVERTER EFFICIENCYENCLOSURE :MAXIMUM INPUT CURRENTMAXIMUM OUTPUT CURRENTMAXIMUM INPUT POWERMAXIMUM OUTPUT POWER41380 V99.0 %NEMA 3R16.5 A25.0 A12,000 W6,000 WSOLAREDGE ENERGY HUB SE6000H-USSN (240V)BATTERY SYSTEMSSOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P8DC DISCONNECT18NON FUSED DC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 600V30AE 1.01930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWE 1.1FROM PV MODULES TO JBOXFROM JBOX TO INVERTER(2)1(1) #6 AWG BARE CU EGC,2 #10 AWG CU EGC,(3)3(1) #10 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A)OUTPUT CALCULATIONSPV SYSTEM MAX DC OUTPUTPV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A)1.251.251.250.91(2)(1) Pmax (PTC Rating)1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOFADJST. FACTOR (1 thru 3 WIRES)1.0FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS3/4'' EMT TYPE CONDUIT1'' EMT TYPE CONDUITMAIN SERVICE PANEL RATINGBUSBAR RATINGMAIN BREAKERPV BACKFEED BREAKER SIZE120% RULE:MAX ALLOWED FEED40A*/*1.25*1.2511400 38018.1/ /18.10.581.031.2#10 AWG THWN-2WIRE CHARTWIRE CHART *11400 4.40 KW* *11373.70.994.07 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT200A200A240A200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAXFROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING11#10 AWG PV-WIREWIRE SIZECALCULATIONS11400LR5-54HABB-400M400 W373.7 W25.0380199.0 %25.0 * 1.25 / 0.9134.4 #8 AWG THWN-2SOLAR EDGE SE6000H-USSN25.0 * 1.2531.31930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWJB BOXWARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)Inverter / PV LoadWARNINGTHE DISCONNECTION OF THEGROUNDING CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTCEC 690.31(E)CEC 690.54AC DisconnectCEC 690.54WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)PM METERMain/Sub PanelCEC 690.54CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59CEC 690.15 (B) & CEC 690.33(D)(2)CEC 690.13(B)SINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUIT!CEC 710.15(C)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)CEC 705.12 (B)(3)(2)LABELING REQUIREMENTS FOR ARTICLE 690CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whetherin the open (off) or closed (on) position and be permanently marked “PV SYSTEMDISCONNECT” or equivalent. Additional markings shall be permitted based uponthe specific system configuration.CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shallsimultaneously disconnect the PV system conductors that are not solidly groundedfrom all conductors of other wiring systems. The PV system disconnecting means orits remote operating device or the enclosure providing access to the disconnectingmeans shall be capable of being locked in accordance with 110.25.CEC 690.15(B) An isolating device shall not be required to have an interruptingrating. Where an isolating device is not rated for interrupting the circuit current, it shallbe marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." Anisolating device shall not be required to simultaneously disconnect all current-carryingconductors of a circuit.CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at alltermination, connection, and splice points by color coding, marking tape, tagging, orother approved means.CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiringmethods and enclosures that contain PV system dc circuit conductors shall be marked with thewording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means ofpermanently affixed labels or other approved permanent marking.CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiringsystem that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing betweenlabels or markings, or between a label and a marking, shall not be more than 3 m (10 ft).Labels required in this section shall be suitable for the environment where they are installed.CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with apermanent, legible warning notice indicating that the disconnection of the groundedconductor(s) may result in overvoltage on the equipment.CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of atool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”.CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors,and inverters shall be considered as internal components of an ac module or ac modulesystem.CEC 690.53 A permanent readily visible label indicating the highestmaximum dc voltage in a PV system, calculated in accordance with 690.7,shall be provided by the installer.CEC 690.54 All interactive system(s) points of interconnection with othersources shall be marked at an accessible location at the disconnectingmeans as a power source and with the rated ac output current and thenominal operating ac voltage.CEC 690.55 The PV system output circuit conductors shall be marked toindicate polarity where connected to energy storage systems.CEC 690.56(A) Plaques or directories shall be installed in accordance with705.10.CEC 690.56(C)(2) A rapid shutdown switch shall have a label located onor no more than 1 meter (3 ft) from the switch.CEC 690.59 PV systems connected to other sources shall be installed inaccordance with Parts I and II of Article 705 and Article 712.SOLAR ELECTRICPV PANELSSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH ON THE"OFF" POSITION TOSHUTDOWN PV SYSTEMAND REDUCESHOCK HAZARDIN ARRAYCFC 1205.4.1(1) & CEC 690.56(C)CEC 690.56(C)(2)CEC 690.31(D)(2)CEC 690.31(D)(2)CONDUIT RATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTWARNINGRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTWARNINGCAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDWARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.WARNINGDO NOT DISCONNECTUNDER LOADRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMWARNING: PHOTOVOLTAICPOWER SOURCEWARNINGPHOTOVOLTAIC POWER SOURCEDO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOWFOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUTDOWN THE ARRAY AND THE CONDUCTORS LEAVINGTHE ARRAY, A LABEL SHALL BE PROVIDED. THEFIRST TWO LINES OF THE LABEL SHALL BEUPPERCASE CHARACTERS WITH A MINIMUMHEIGHT OF 3/8 INCH (10 MM) IN BLACK ON AYELLOW BACKGROUND. THE REMAININGCHARACTERS SHALL BE UPPERCASE WITH AMINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ONA WHITE BACKGROUND. [CFC 1205.4.1(1)]240 Vac240 Vac240 VacCEC 690.13(B)AC DISCONNECTPHOTOVOLTAIC25.0 A25.0 A25.0 A CEC 705.10CAUTIONMULTIPLE SOURCES OF POWER CEC 705.10CAUTIONMULTIPLE SOURCES OF POWERCEC 690.53MAXIMUM SYSTEM VOLTAGERATED SHORT CIRCUIT CURRENTN/AMAX RATED AC OPERATING VOLTAGEN/ARATED AC OPERATING VOLTAGEMAX RATED AC OPERATING CURRENTRATED AC OPERATING CURRENTN/AN/AN/AN/ACODE REQUIREDSIGNAGECAUTIONN 0°S 180°E 90°W 270°MULTIPLE SOURCES OF POWERCEC 705.10 & CEC 710.10Permanent directory or plaque providing location of service disconnecting means andphotovoltaic system disconnecting means, if not located at the same location. (Plaques shallbe metal or plastic, with engraved or machine printed letters, or electro-photo plating, in acontrasting color to the plaque. Plaques shall be permanently attached to the equipment or in therequired location using an approved method that is suitable to withstand the environment to which itis exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesionrequirements of Underwriters Laboratories marking and labeling system 969(UL969).Plaques will have red background & white lettering.CEC 480.7(B)EMERGENCY DISCONNECTS A
R
T
E
S
I
A
S
T INVERTERAC DISCONNECTMAIN SERVICE PANELESS DISCONNECTDC DISCONNECTPV 2.01930 S Artesia St11/27/2024
PV 2.1PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KW[FOR INSTALLER USE ONLY]PHOTOVOLTAIC SYSTEM4.40 KW DCMODULE MAP11 Longi Solar 400W Modules (LR5-54HABB-400M)11Solar Edge S500 Power Optimizers1Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNSolar Array 18 Longi Solar 400W8 S500 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S500 OptimizersTilt: 16 DegAzimuth: 115 Deg1930 S Artesia St11/27/2024
PV 3.0PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWINVERTERPHOTOVOLTAIC SYSTEM4.40 KW DC[FOR INSTALLER USE ONLY]INVERTER MAP11Longi Solar 400W Modules (LR5-54HABB-400M)11Solar Edge S500 Power Optimizers1Solar Edge Energy Hub 6.0 Kw Inverter SE6000H-USSNSolar Array 18 Longi Solar 400W8 S500 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S500 OptimizersTilt: 16 DegAzimuth: 115 Deg1930 S Artesia St11/27/2024
PV 3.1PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWMODULEDATA SHEET1930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 4.0INVERTERDATA SHEET1930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 5.1ATTACHMENTDATA SHEET1930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 5.0RACKINGDATA SHEET1930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 6.0GROUNDINGSPECS1930 S Artesia St11/27/2024
PV SYSTEMAS INDICATEDJuly 30, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWPV 6.1BATTERYDATA SHEET1930 S Artesia St11/27/2024
1930 S. ARTESIA ST.
SANTA ANA, CA 92704
SIBRIAN, BERTA
Design Criteria
1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16
2 - Wind: 95 MPH, Exposure: C
3 - Wood Species: DF-L No. 2 (SG = 0.5 )
Notice: Use restrictions of these calculations.
The attached Calculations are valid only when bearing original signature hereon.
Contractor/Client to verify existing dimensions/conditions prior to construction
& solar racking is installed per manufacturer span requirements.
The use of these calculations is solely intended for the above mentioned project.
1-844-PV ELITE | info@yoursolarplans.com
3000 E. Birch Street Suite 201 | Brea CA 92821
7/30/2024
Structural Calculations for
SOLAR POWER SYSTEM CONNECTION CHECK AT:
Job:
1930 S Artesia St
11/27/2024
1930 S Artesia St
11/27/2024
ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes.
Roof Slope =16 °
Roof Shape Hip
Tributary Width s =4.00 ft
Tributary Length l =2.82 ft
Effective Area Ae =11.30 ft2
Height of Structure h =15 ft
Wind Speed V =95 mph
Exposure Category C
Building Width B =30 ft
Building Length L =50 ft
Zone Width a =3ft
Elevation Height zg =49 ft
Wind Directionality Kd =0.85
Topography Factor Kt =1.00
Ground Elevation Factor Ke =1.00
Velocity Pressure Exposure Coefficient Kz =0.85
Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.64 psf
Solar Array Pressure Equalization a =0.79
Array Edge Factor E =1.50
Zone GCp p = qz(GCp)(E)(a)
3 2.59 -51.38
3r - -
3e - -
2--
2r 2.38 -47.27
2e 2.59 -51.38
2n - -
1 1.80 -35.69
1' - -
1930 S Artesia St
11/27/2024
LAG SCREW ANALYSIS
Loads
Wind Pressures qz =-51.38 psf
Solar Panel Load QD =3 psf
Panel Length l =5.650 ft
Panel Width b 3.7205 ft
Attachment Spacing s =4ft
Portrait
Tributary Area At =11.30 ft2
Wind Load PW = qz * At =-581 lbs
Dead Load PD = QD * At =33.898 lbs
Uplift Pa = 0.6 PD + 0.6 Pw =-328 lbs
Landscape
Tributary Area At = b * s =7.4409 ft2
Wind Load PW = qz * At =-382 lbs
Dead Load PD = QD * At =22.323 lbs
Uplift Pa = 0.6 PD + 0.6 Pw =-216 lbs
Lag Screw
Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch)
Diameter of Lag Screw D =5/16 in
Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in
Depth of Embedment lp =2.50 in
Total Nominal Withdrawal Value W = W * l p =665 lbs
Load Duration Factor CD =1.6
Withdrawal Design Value W' = W * C D =1064 lbs
Demand Capacity Ratio DCR = Pa / W'=0.31 < 1 OK
1930 S Artesia St
11/27/2024
ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check
Roof Slope =16 °
Roof Shape Hip
Tributary Width s =2.00 ft
Tributary Length L =13.50 ft
Effective Area A = L ( MAX [ s , L/3] )=61 ft2
Height of Structure h =15 ft
Wind Speed V =95 mph
Exposure Category C
Building Width B =30 ft
Building Length L =50 ft
Zone Width a =3ft
Elevation Height zg =49 ft
Wind Directionality Kd =0.85
Topography Factor Kt =1.00
Ground Elevation Factor Ke =1.00
Velocity Pressure Exposure Coefficient Kz =0.85
Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.64 psf
Internal Pressure Coefficient (GCpi)=-0.18
Zone GCp
p = qz [(GCp) - (Gcpi)]
3 2.28 -40.93
3r - -
3e - -
2--
2r 1.78 -32.61
2e 2.28 -40.93
2n - -
1 1.39 -26.17
1' - -
1930 S Artesia St
11/27/2024
Beam/ Top Chord Check Lumber:
Moment Demand
# of Attachment per Rafter NA =Span :Orientation
Lenght (ft) :
Dead Load Roof Material:QD =psf
Live Load QLr =psf
Wind Load p = psf
Snow Load QS =psf
Rafter Spacing s = in
Wind Load, Portrait Portrait UL =
Wind Load, Landscape Landscape UW =
Linear Dead Load wd =plf
Live Load wLr = plf Start ft Start ft
End ft End ft
Snow Load ws = plf Start ft Start ft
End ft End ft
Ma, Moment
D lb-ft
D+Lr lb-ft
D+S lb-ft
0.6D+0.6W lb-ft
D+0.45W+0.75Lr lb-ft
D+0.45W+0.75S lb-ft
Moment Capacity Framing Member Size Lumber Grade : DF-L No. 2
CM = 1 Ct = 1 Cr=CF = fb =psi Cfu =Ci =
Breadth b = in
Depth d = in
Section Modulus Sx = bd 2 / 6 =in3
Bending Stress Capacity Fb = CM * Ct * Cr * C F * fb =psi Table 4.3.1 NDS 2015
Deflection Limit E = ksi I =in4
Transient Deflection in
Transient Deflection Allowed > [OKAY]
Total Deflection in
Total Deflection Allowed > [OKAY]
-40.93
DF-L No. 2
4 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs)
Portrait 1 2.2 33.9 -462 0.0
6.4 33.9 -462
-462 0.0
4 12.1 33.9 -462 0.0
0.0
8.00 4.50 0.00 0.00 1.00
Portrait 3 7.9 33.9
10.00
1234Eave
2
0.0
0.0 0.0 0.0
0.0
0 0.0 0.0 0.0 0.0
0 0.0 0.0 0.0
0.0
0 0.0 0.0 0 0.0
Portrait 0 0.0 0.0 0
0.0
20
40
0.0 0.0 0.0 0.0
0 0.0
Portrait 0
0.022.323 -305 0
0
0.0
0
1.5
0
0
0.0
Portrait
1.5
0.0Portrait0 0.0 0.0
AT (ft2)
11.299
7.4409
pd (lbs)
33.898 -462
pw (lbs) ps (lbs)
0
12.80
2x4
1.15 1.5
13.50
12.80
13.50
900
1.50
3.50
169
174
169
367
192
192
DCR
0.9 1397 psi D 662 psi 0.47
3.06
1553
CD Fb' = CD * Fb ASD Load Ma / Sx
1.15 1785 psi D+S 662 psi 0.37 OKAY
OKAY
1.25 1941 psi D+Lr 684 psi 0.35 OKAY
1.6 2484 psi
0.364
263 120
1600 5.36
0.6D+0.6W 1437 psi 0.58 OKAY
1.0 1
20
0.00
24
Comp
0.330
291 180
1.6 2484 psi D+0.45W+0.75S 751 psi 0.30 OKAY
1.6 2484 psi D+0.45W+0.75Lr 751 psi 0.30 OKAY
𝑴𝒙ൌ𝑹𝒊ሺ𝒙െ𝑳𝒊ሻെ𝑷𝒋𝒙െ𝒍𝒋െ 𝒘𝒅𝒙𝟐
𝟐
‐400.0
‐200.0
0.0
200.0
400.0
600.0
0.000 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000
1930 S Artesia St
11/27/2024
EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5)
PV System Weight
Module Model Longi
Panel Weight W panel = 49.6 lbs
Number of Panels NPV =11
Total PV System Weight W PV = W panel * NPV =545.6 lbs
Existing Roof Weight
Roof Weight QD =10.0 psf
Building Length Lbuild =50 ft
Building Width W build =30 ft
Roof Area Abuild =1500 ft2
Building Perimeter Pbuild =160 ft
Wall Height ht =8ft
Wall weight Qwall =15 psf
Interior wall weight Qint =10 psf
Roof Load W floor = Abuild * QD =15000 lbs
Wall LoadW wall = ht /2 * Qwall * Pbuild + Abuild * Qint /2 =17100 lbs
Total Story Weight W build = W floor + W wall =32100 lbs
Percentage Weight Increase WPV / Wbuild = 1.70% < 10% OKAY
1930 S Artesia St
11/27/2024
•• ••• ••
CLEAN ENERGY
SOLUTIONS
To whom it may concern,
Clean Energy Solutions
417 W. Allen Ave Suite #105
San Dimas CA, 91773
800)994-1134
This letter authorizes Bernard Albosta to pull permits/ business license on behalf of Clean Energy Solutions.
If you have any question, please call us at 800) 994-1134
Sincerely,
David Gomez
CEO
A notary public or other officer comple�ng this
cerlificate verifies only the Identity of the
individual who signed lhe document 10 which lhis
certificate is attached, and nol the lruthlulness
accuracy, or validily of lhat document.
State of California County of / f)S �lc.J
Subscribe�nd sworn to (or affirmed)beore me
on thisl_day of ?:(� ,20 1-!J
by � Q-y\<k (-,ol\Jv+;.
proved to me on the basis of satisfactory evidence
to be the person( who app ared before me.
Signature (Nolary Seat)
'
@
ANDRE ROBINSONI , r. COMM # 2433203 �
:;; NOTARY PUBLIC· CAUFORNIA !'? I LOS ANGELES COUNTY Ilily Com! Ell)ltS JANUARY ll. 2027
q • 0
1930 S Artesia St
11/27/2024
1930 S Artesia St11/27/2024
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
1930 S Artesia St Santa Ana, CA 92704
Bernard Albosta
998787
Bernard Albosta
mluna@cleanenrgysolar.orgPhone Number: 8009941134 10/4/24
1930 S Artesia St
11/27/2024
0
PV SYSTEM
AS INDICATED
November 12, 2024
BERTA J SIBRIAN
1930 S ARTESIA ST,
SANTA ANA, CA 92704
Clean Energy Solutions Inc.
Address:
1055 West 7th Street
33rd Floor, Los Angeles,
CA 90017
Phone Number:
(800) 994 1134
Lic# 998787
Class C-10
CONTRACTOR
Designed By: Intersolar CAD
www.intersolarcad.com
PV SYSTEM DC SIZE 4.40KW
PV SYSTEM AC SIZE 4.07KW
COVER PAGE
1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE
COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY
2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED
3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED
4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER.
5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING
COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED.
6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY
AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL
INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY.
7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE
COORDINATED WITH OTHER TRADES.
8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS
RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT.
9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE
WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE.
10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE
SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS.
OWNER
SCOPE
PROJECT
ADDRESS
PROJECT DATA GENERAL NOTES VICINITY MAP
SHEET INDEX
0 COVER PAGE
PHOTOVOLTAIC NOTES
SATELLITE VIEW
BUILDING
INFORMATION:
SINGLE LINE DIAGRAM
CODE REQUIRED SIGNAGE
3
4
ATTACHMENT LAYOUT5
6
7
INVERTER DATA SHEET
D1 MODULE DATA SHEET
RACKING DATA SHEET
RACKING CERTIFICATE
ATTACHMENT DATA SHEET
ELECTRICAL
INFORMATION
MAIN SERVICE PANEL
BUSBAR RATING
MAIN SERVICE
BREAKER RATING
1ɸ, 3W, 120/240V
ROOF PLAN
MODULE MAP
RACKING
INFORMATION
Main Service Panel
Solar Module
Micro Inverter /
Optimizer
EMT / FMT / PVC
/ RMC type conduit/
Romex NM Cable/
FNMT (Fluid non-metalic tube)
36'' SetbackInverter
Utility Meter
Production Meter
PV Load Center
IQ Combiner Box
Junction Box
Sunpower PV Supervisor
18'' Setback
EV Outlet
CONSTRUCTION TYPE: V-B
ROOF
TYPE
AHJ
APN
LOT AREA
LIVING AREA
MSP
UM
PM
INV
PV
PVS6
IQ
J/B
EV
BERTA J SIBRIAN
11
1930 S ARTESIA ST,
SANTA ANA, CA 92704
SSP Service Sub Panel
COMPOSITION SHINGLE
1,775 SQFT
40836409
CITY OF SANTA ANA
WIRE SIZE CALCULATIONS
INVERTER MAP
D2
D3
D4
D5
D6
GROUNDING SPECSD7
ROOF MOUNT INSTALLATION OF
DC PHOTOVOLTAIC SYSTEM
4.40 KW DC
4.40 KW
4.07 KW AC
NEW UPGRADED
ALL OTHER ORDINANCE ADOPTED BY THE
LOCAL GOVERNING AGENCIES
THE INSTALLATION OF SOLAR ARRAYS AND
PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY
WITH THE FOLLOWING CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
2022 CALIFORNIA HISTORICAL CODE
2022 CALIFORNIA EXISTING BUILDING CODE
2022 CALIFORNIA REFERENCED STANDARDS CODE
2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE
1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703.
2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS
3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED.
4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER
OUTAGE.
5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING
ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS.
6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE.
7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE
ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED.
8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION
9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED
10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT.
11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING
MEANS AS PER 230.82(6)
12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING
AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122
13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122.
14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS
OPTIMIZER DATA SHEET
1
2
6,100 SQFT 1.1 SITE PLAN
Battery BackupBB
Auto TransformerAT
Solar Edge Meter EnclosureSEM
Distribution PanelDP
Rapid Shutdown ControllerRSC
Rapid Shutdown BoxRSB
Itron MeterIM
UNIT INDEX
CODE REFERENCES
IRONRIDGE RACKING
RAFTERS 2"X4" @ 24" O.C
OCCUPANCY: R
ONE STORY BUILDING
200A
200A
(don't delete this note)
AC DisconnectACD
Visible Lockable
Labeled DisconnectVLLD
D8 BATTERY DATA SHEET
LONGI SOLAR 400W
LR5-54HABB-400M
SOLAR EDGE SE5700H-USMNUBL15 (240V)
1 SOLAREDGE BAT-10K1PS0B-01
ENERGY BANK 10KWH
D9
D10
BATTERY INSTALLATION MANUAL
BATTERY MOUNTING DETAILS
1
The scope of the plans is for the
installation of the solar photovoltaic
system only and the approval is subject
to compliance with all applicable city
and state codes and regulations
regarding construction. The approval of
the plans does not constitute any
certification of the accuracy,
completeness, or building permit status
of the existing buildings and structures
as shown.
Bldg# 101122088
Elec#: 20184808
Revision to:
Bldg#: 101121407
Elec#: 20184383
Approvals:
Elec: M Smith
1930 S Artesia St
1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWROOF AREA CALCULATIONSFIRE SPRINKLERS - NOTOTAL ROOF AREA (SQ.FT.) - 3375SOLAR AREA (SQ.FT.) - 231% OF COVERED AREA - 6.8%PHOTOVOLTAIC SYSTEMFROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVERTHE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.40 KW DCROOF PLAN36'' Setback18'' Setback11Longi Solar 400W Modules (LR5-54HABB-400M)Solar Edge S440 Power Optimizers11NOTE: BATTERIES WILL BE INSTALLED A MIN 3FT AWAYFROM DOORS AND WINDOWS LEADING INSIDE THE HOUSE1Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V)N 0°S 180°E 90°W 270°SCALE1" = 10'MSPINVACDS A
R
T
E
S
I
A
S
TSolar Array 18 Longi Solar 400W8 S440 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S440 OptimizersTilt: 16 DegAzimuth: 115 DegSolarEdge Energy Bank BatteryJ/BDCDPV 0.01930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSITE PLANN 0°S 180°E 90°W 270°SCALE1" = 15'MSPINVACD100'20'5'32'44'DrivewayPu
b
l
i
c
S
i
d
e
w
a
l
k
Public Sidewalk
S A
R
T
E
S
I
A
S
T
S RAITT ST
(E)
M
A
I
N
H
O
U
S
EPROPERTY LINESolarEdge Energy Bank Battery15'60'10'(E) PATIO(E) PATIODCDPV 1.01930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWSTRUCTURAL STAMPROOFPITCHROOFINGTYPEATTACHMENTTYPEFRAMINGTYPEFRAMINGSIZEPENETRATIONPATTERN16°RACKINGTYPEMAXPENETRATIONSPACINGROOFINGLAYERSWIND SPEED95 MPHSNOW LOAD0 PSFEXPOSURECLAG BOLTSMOUNTS AND MOUNTING HARDWARE WILL BESEALED WITH CHEM LINK SEALANT OR EQUIVALENT.MODULE WEIGHT (LBS)# OF MODULESTOTAL MODULE WEIGHT (LBS)RACK WEIGHT (LBS)TOTAL SYSTEM WEIGHT (LBS)# OF STANDOFFSLOADING PER STANDOFF (LBS)TOTAL MODULE AREA (SQ.FT.)LOADING (PSF)WEIGHT LOAD CALCULATIONINDEXROOF SHEATHED WITH 1/2" PLYWOOD AND UPPERSURFACE IS FACED WITH FELT PAPERTOTAL ROOF AREA (Sq. FT)% OF COVERED AREAPV MODULE MODEL #11Roof1 LayerComp ShingleIronridge XR10RafterStacked48"2"X4" @ 24" O.C3124ITEM NO.1DESCRIPTION234BOLT LAG 5/16 X 4.75"ASSY, FLASHINGASSY, CAPFOOTWASHER, EPDM BACKEDQty in Kit44445/16" X 4.75"Flash Foot 2MIN 2.5" EMBEDMENTRACKING RAILATTACHMENTROOF FRAMING2823133755461091767124.02.916.82''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar TieSOLAR MODULEROOFASCE 7-16Max 3.5'' ATTACHMENTLAYOUT49.6LR5-54HABB-400MOPTIMIZERS WEIGHT (LBS)48"24"S 1.01930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWITEMDESCRIPTIONQTY#PV MODULEMAIN SERVICE PANELMAIN SERVICE PANEL& UTILITY METERBUSBAR RATINGBREAKER RATING1ITEMDESCRIPTIONQTY#PVC JUNCTION BOX4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 311143146MAINSERVICEPANEL120/240V1P,3W2EXISTINGGROUNDING SYSTEMUTILITY2360AAC DISCONNECTNON FUSED AC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 120/240V16NEW UPGRADEDNEW2133200A200A200AFOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3String: (11) Modules, (11) OptimizersSINGLE LINEDIAGRAM7(2)#10 AWG (10-12 AWG), 600V insulated(1)#24 AWG (16-24 AWG), 600V insulated or CAT61" EMT TYPE ConduitBATTERY17EXTERIOR KNIFE SWITCH TYPE DISCONNECTINSTALL 2P30A CB(PV) ATOPPOSITE ENDOF BUS FROMMAIN FEEDER CB(N)200A11LONGI SOLAR 400WLR5-54HABB-400MVoc = 37.05VVmp = 30.94VIsc = 13.72AImp = 12.93ASOLAREDGE POWER OPTIMIZERRATED DC INPUT POWERMAXIMUM INPUT VOLTAGEMPPT RANGEMAXIMUM SHORT CIRCUIT CURRENT (Isc)MAXIMUM OUTPUT CURRENTOPTIMIZER WEIGHTMAXIMUM POWER PER STRING5S440440W60 Vdc8 to 60 Vdc14.5 Adc15 Adc1.5 Lbs11POWER OPTIMIZER380 V99.0 %NEMA 413.5 A24.0 A11,520 W5,760 WINVERTERPEAK PWR TRACKING VOLTAGEMAXIMUM INPUT CURRENTMAXIMUM OUTPUT CURRENTMAXIMUM INPUT POWERMAXIMUM CONTINUOUS OUTPUT POWER45700W1SOLAREDGE SE5700H-USMNUBL15 (240V)ENCLOSURE:INVERTER EFFICIENCYBATTERY SYSTEMSSOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P8DC DISCONNECT18NON FUSED DC DISCONNECT LOCKABLE,BLADE TYPE, NEMA 3R, 600V30AE 1.01930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWFROM PV MODULES TO JBOXFROM JBOX TO INVERTER(2)1(1) #6 AWG BARE CU EGC,2 #10 AWG CU EGC,(3)3(1) #10 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A)OUTPUT CALCULATIONSPV SYSTEM MAX DC OUTPUTPV SYSTEM MAX AC OUTPUT MAXIMUM POWER (W) PEAK PWR TRACKING VOLTAGE (V) CONSIDER CONTINUOUS COEFFICIENT SHORT CIRCUIT CURRENT (A) ADJUSTED CONDUCTOR AMPACITY (A)1.251.251.250.91(2)(1) Pmax (PTC Rating)1 1/2'' (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOFADJST. FACTOR (1 thru 3 WIRES)1.0FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS3/4'' EMT TYPE CONDUIT1'' EMT TYPE CONDUITMAIN SERVICE PANEL RATINGBUSBAR RATINGMAIN BREAKERPV BACKFEED BREAKER SIZE120% RULE:MAX ALLOWED FEED30A*/*1.25*1.251140038018.1//18.10.581.031.2#10 AWG THWN-2WIRE CHARTWIRE CHART *11400 4.40 KW**11373.70.994.07 KW CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS COEFFICIENT200A200A240A200A ''MB'' + 30A "SOLAR" = 230A ≤ 240A MAXFROM INVERTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) MAX NUMBER OF MODULES IN STRING11#10 AWG PV-WIREWIRE SIZECALCULATIONS11400LR5-54HABB-400M400 W373.7 W38099 %1 #10 AWG THWN-224.0 * 1.25 / 0.9124.033.0 SOLAR EDGE SE5700H-USMNUBL15 (240V)24.0 * 1.2530.0E 1.11930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWJB BOXWARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)Inverter / PV LoadWARNINGTHE DISCONNECTION OF THEGROUNDING CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTCEC 690.31(E)CEC 690.54AC DisconnectCEC 690.54WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)PM METERMain/Sub PanelCEC 690.54CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59CEC 690.15 (B) & CEC 690.33(D)(2)CEC 690.13(B)SINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUIT!CEC 710.15(C)TURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELCEC 110.27(C)WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONCEC 690.13(B)CEC 705.12 (B)(3)(2)LABELING REQUIREMENTS FOR ARTICLE 690CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whetherin the open (off) or closed (on) position and be permanently marked “PV SYSTEMDISCONNECT” or equivalent. Additional markings shall be permitted based uponthe specific system configuration.CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shallsimultaneously disconnect the PV system conductors that are not solidly groundedfrom all conductors of other wiring systems. The PV system disconnecting means orits remote operating device or the enclosure providing access to the disconnectingmeans shall be capable of being locked in accordance with 110.25.CEC 690.15(B) An isolating device shall not be required to have an interruptingrating. Where an isolating device is not rated for interrupting the circuit current, it shallbe marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." Anisolating device shall not be required to simultaneously disconnect all current-carryingconductors of a circuit.CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at alltermination, connection, and splice points by color coding, marking tape, tagging, orother approved means.CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiringmethods and enclosures that contain PV system dc circuit conductors shall be marked with thewording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means ofpermanently affixed labels or other approved permanent marking.CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiringsystem that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing betweenlabels or markings, or between a label and a marking, shall not be more than 3 m (10 ft).Labels required in this section shall be suitable for the environment where they are installed.CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with apermanent, legible warning notice indicating that the disconnection of the groundedconductor(s) may result in overvoltage on the equipment.CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of atool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”.CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors,and inverters shall be considered as internal components of an ac module or ac modulesystem.CEC 690.53 A permanent readily visible label indicating the highestmaximum dc voltage in a PV system, calculated in accordance with 690.7,shall be provided by the installer.CEC 690.54 All interactive system(s) points of interconnection with othersources shall be marked at an accessible location at the disconnectingmeans as a power source and with the rated ac output current and thenominal operating ac voltage.CEC 690.55 The PV system output circuit conductors shall be marked toindicate polarity where connected to energy storage systems.CEC 690.56(A) Plaques or directories shall be installed in accordance with705.10.CEC 690.56(C)(2) A rapid shutdown switch shall have a label located onor no more than 1 meter (3 ft) from the switch.CEC 690.59 PV systems connected to other sources shall be installed inaccordance with Parts I and II of Article 705 and Article 712.SOLAR ELECTRICPV PANELSSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH ON THE"OFF" POSITION TOSHUTDOWN PV SYSTEMAND REDUCESHOCK HAZARDIN ARRAYCFC 1205.4.1(1) & CEC 690.56(C)CEC 690.56(C)(2)CEC 690.31(D)(2)CEC 690.31(D)(2)CONDUIT RATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTWARNINGRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTRATED AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE:PHOTOVOLTAIC AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTWARNINGCAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDWARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.WARNINGDO NOT DISCONNECTUNDER LOADRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMWARNING: PHOTOVOLTAICPOWER SOURCEWARNINGPHOTOVOLTAIC POWER SOURCEDO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOWFOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUTDOWN THE ARRAY AND THE CONDUCTORS LEAVINGTHE ARRAY, A LABEL SHALL BE PROVIDED. THEFIRST TWO LINES OF THE LABEL SHALL BEUPPERCASE CHARACTERS WITH A MINIMUMHEIGHT OF 3/8 INCH (10 MM) IN BLACK ON AYELLOW BACKGROUND. THE REMAININGCHARACTERS SHALL BE UPPERCASE WITH AMINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ONA WHITE BACKGROUND. [CFC 1205.4.1(1)]240 Vac240 Vac240 VacCEC 690.13(B)AC DISCONNECTPHOTOVOLTAIC25.0 A25.0 A25.0 A CEC 705.10CAUTIONMULTIPLE SOURCES OF POWER CEC 705.10CAUTIONMULTIPLE SOURCES OF POWERCEC 690.53MAXIMUM SYSTEM VOLTAGERATED SHORT CIRCUIT CURRENTN/AMAX RATED AC OPERATING VOLTAGEN/ARATED AC OPERATING VOLTAGEMAX RATED AC OPERATING CURRENTRATED AC OPERATING CURRENTN/AN/AN/AN/ACODE REQUIREDSIGNAGECAUTIONN 0°S 180°E 90°W 270°MULTIPLE SOURCES OF POWERCEC 705.10 & CEC 710.10Permanent directory or plaque providing location of service disconnecting means andphotovoltaic system disconnecting means, if not located at the same location. (Plaques shallbe metal or plastic, with engraved or machine printed letters, or electro-photo plating, in acontrasting color to the plaque. Plaques shall be permanently attached to the equipment or in therequired location using an approved method that is suitable to withstand the environment to which itis exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesionrequirements of Underwriters Laboratories marking and labeling system 969(UL969).Plaques will have red background & white lettering.CEC 480.7(B)EMERGENCY DISCONNECTS A
R
T
E
S
I
A
S
T INVERTERAC DISCONNECTMAIN SERVICE PANELESS DISCONNECTDC DISCONNECTPV 2.01930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KW[FOR INSTALLER USE ONLY]PHOTOVOLTAIC SYSTEM4.40 KW DCMODULE MAP11Longi Solar 400W Modules (LR5-54HABB-400M)Solar Edge S440 Power Optimizers111Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V)Solar Array 18 Longi Solar 400W8 S440 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S440 OptimizersTilt: 16 DegAzimuth: 115 DegPV 2.11930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWINVERTERPHOTOVOLTAIC SYSTEM4.40 KW DC[FOR INSTALLER USE ONLY]INVERTER MAP11Longi Solar 400W Modules (LR5-54HABB-400M)Solar Edge S440 Power Optimizers111Solar Edge 5.7 Kw Inverter SE5700H-USMNUBL15 (240V)Solar Array 18 Longi Solar 400W8 S440 OptimizersTilt: 16 DegAzimuth: 205 DegSolar Array 23 Longi Solar 400W3 S440 OptimizersTilt: 16 DegAzimuth: 115 DegPV 3.01930 S Artesia St1/23/2025
PV SYSTEMAS INDICATEDNovember 12, 2024BERTA J SIBRIAN1930 S ARTESIA ST,SANTA ANA, CA 92704Clean Energy Solutions Inc.Address:1055 West 7th Street33rd Floor, Los Angeles,CA 90017Phone Number:(800) 994 1134Lic# 998787Class C-10CONTRACTORDesigned By: Intersolar CADwww.intersolarcad.comPV SYSTEM DC SIZE 4.40KWPV SYSTEM AC SIZE 4.07KWINVERTERDATA SHEETPV 4.01930 S Artesia St1/23/2025
1930 S Artesia St1/23/2025
--- - -
---
-
-
-
-
1930 S Artesia St Santa Ana, CA 92704
101121407 11/25/2024
$460.36
Smith, Mark
Bernard Albosta
Clean Energy Solutions
web_issue
800 994-1134
Melissa Luna
mluna@cleanenergysolar.org
800 994-1134
The equipment location has been changed.
The power optimizer has been changed.
The inverter type has been changed.
The PV breaker size has been changed.
1930 S Artesia St
1/23/2025