HomeMy WebLinkAbout526 S Ross St - 101122337 & 20185008 - PlanPAGE
REV: C 2/1/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD.SUITE A,IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
COVER SHEET
SCOPE OF WORK GENERAL NOTES
PV-1.0
VICINITY MAP
#SSTAMPCS
#ESTAMPCS
ABBREVIATIONS
A AMPERE
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT
(E)EXISTING
ESS ENERGY STORAGE SYSTEM
MSP MAIN SERVICE PANEL
(N) NEW
PRE-FAB PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS
V VOLTS
W WATTS
SHEET INDEX
REV NAME DATE COMMENTS
PAGE # DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-3.0 LAYOUT
PV-3.1 MOUNTING DETAIL
PV-4.0 ELECTRICAL
PV-4.1 ELECTRICAL CONT.
PV-4.2 ELECTRICAL CALCS
PV-4.3 BACKUPLOAD CALCS
PV-4.4 PANEL SCHEDULE
PV-5.0 SIGNAGE
PV-5.1 SIGNAGE
2022 CRC/CBC/CEBC, 7-16 ASCE & 2018 NDS,
MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS.
CEC 2022.
CEC 2022.
INVERTER. SYSTEM COMPLIES WITH 690.41(A).
ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE
THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS
14.88 AMPS MODULE SHORT CIRCUIT CURRENT.
23.25 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)].
VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B).
THROUGH A WALL OR PARTITION PER 706.15(D).
THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D).
BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A)
LTD: LR5-54HABB-400M
1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh PER
PW3
TOTAL ENERGY CAPACITY (IN kWh): 27kWH
(MCI-2) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS
BACKUP GATEWAY : (1) 200A TESLA, 1841000-01-C, ENERGY
GATEWAY 3
EXISTING SYSTEM SIZE: 5.265KW DC, 3800KW AC
COMBINED SYSTEM SIZE: 10.865KW DC, 26800KW AC
**The scope of the plans is for the installation
of the solar photovoltaic system only and the
approval is subject to compliance with all
applicable city and state codes and
regulations regarding construction. The
approval of the plans does not constitute any
certification of the accuracy, completeness, or
building permit status of the existing
buildings and structures as shown. **
Bldg #101122337 & Elect #20185008
APPROVALS:
ELECT - M. Smith
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: E 2/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
PL PL PL PL
PLPLPLPLPLPL
SITE PLAN
PV-2.0
#SSTAMPSP
#ESTAMPSP
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
NOTE: ROOFTOP MODULE LEVEL RAPID
SHUTDOWN DEVICE INSTALLED PER CEC
690.12
SITE PLAN - SCALE = 0'-0 3/64" = 1'-0"
(E) DETACHED
GARAGE (TYP.)
(E) PV ARRAY (TYP.)
(N) ARRAY AR-01
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
(N) ARRAY AR-02
(E) FENCE
AINV
AC AGP
MP
SE
MD
AC
INVAAA AAA(E) RESIDENCE
ROOF PATHWAYS
(3' TYP)
(E) GATE (TYP.)BBBBBBS ROSS STSITE PLAN - SCALE =
(E) PV EQUIPMENT
NOTES:
RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
TOTAL ROOF SURFACE AREA: 2172.0 SQFT.
TOTAL PV ARRAY AREA(E+N): 564.72 SQ FT.
PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 (E+N)= 26%
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 26° 168.2
AR-02 26° 126.1590°
TRUE
AZIM
MAG
AZIM
348°0°
78°
(E) DETACHED
STORAGE (TYP.)
(E) DETACHED
SHED (TYP.)
INTERIOR EQUIPMENT
SHOWN AS DASHED
POWERWALL ENERGY
STORAGE SYSTEM (ESS)
COMMUNICATION
WIRES
GROUNDING
ELECTRODE
SE
MP
SM
PM
SP
MAIN PANEL
SERVICE ENTRANCE
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
LC
LEGEND ELECTRIC VEHICLE
SUPPLY EQUPMENT
ACREL METER
IQ COMBINER BOX
ENERGY STORAGE
SYSTEMDC DISCONNECT(S)
AC DISCONNECT(S)
INVERTER(S)
SOLAREDGE METER
INV
DC
SUB-PANEL
AC
DEDICATED PV METER
SUNRUN METER
SEMPV LOAD CENTER
EV
AM
CB BP
BI 1 BACKUP INTERFACE
METER ADAPTER
BACKUP LOADS PANEL
MD MICROGRID
INTERCONNECT DEVICE
MA
GENERATION PANELGP
BACKUP GATEWAYBG
RSD
EXTERNAL
RAPID
SHUTDOWN
SWITCH
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
SP
E
E
Signed: 03/01/2025
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: A 1/16/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
MOUNTING DETAIL
PV-3.1
#SSTAMP
UR-40 RAIL | UR-60 RAIL
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
PENETRATION DETAIL
INSTALLED SECTION VIEW
DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER:
APPROVED BY:
REVISION:
Sunrun South LLC
595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA
PHONE (415) 580-6900 ● FAX (415) 580-6902
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE
WRITTEN CONSENT OF SUNRUN SOUTH LLC.
ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA
L FOOT TO RAFTERSNR-DC-00339
1 5 7 2019 NEW DETAIL
1 6 18 2019 DRO-00138
B 6 22 2023 DC002707
REV:
ADATE:
DNS
6 22 2023
DRAFTER: M.AFFENTRANGER
E.FERGUSON
M.AFFENTRANGER
Solar Mounting Solutions
MJA
MJA
MJA
BIN:
8
214"
112"
112"
158"
SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING
FOR COMPOSTION ROOF MOUNTING
REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL
SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON
THIS DRAWING
516"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212" INTO
STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING.
REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE
REFER TO SNAPNRACK INSTALLATION MANUAL FOR516"Ø HARDWARE
TORQUE SPECIFICATIONS
RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT
FOR LEVELING DETAILS, REFER TO SNAPNRACK
DETAIL DRAWING "SNR-DC-00447"
STRUCUTRAL MEMBER,
WOOD RAFTER, TYP.
ROOF DECKING, TYP.
SNAPNRACK5 16"n UMBRELLA
LAG SCREW, S.S.
COMP SHINGLE ROOFING, TYP.
SNAPNRACK
ULTRA RAIL
SNAPNRACK UMBRELLA FLASHING
212" MIN. EMBEDMENT
INTO WOOD MEMBER
MODULE HEIGHT OFF ROOF:
UR-40: 338" - 438"
UR-60: 4" - 5"
SNAPNRACK ULTRA RAIL
UMBRELLA L FOOT
STRUCUTRAL MEMBER,
WOOD RAFTER, TYP.
ROOF DECKING, TYP.
COMP SHINGLE ROOFING, TYP.
SNAPNRACK ULTRA RAIL
UMBRELLA L FOOT WITH
UMBRELLA LAG AND FLASHING
SNAPNRACK
UMBRELLA FLASHING
01/16/2025
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: A 1/16/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
#SSTAMP
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED:
96 MPH 3-SEC GUST.
FASTENERS:
(1) 5/16" DIA S.S. UMBRELLA
SCREW: 2.5" MIN EMBEDMENT
INTO FRAMING
PV-3.0
LAYOUT
SOLAR MODULE
SNAPNRACK
RACKING
4"
MODULE ELEVATION DETAIL - SCALE: NTS
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Name Type Height Type
Max
Span
OC
Spacing Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-01 COMP SHINGLE - UR -
UMBRELLA L FOOT 1-Story 2X4 RAFTERS 7'-5"24"
ULTRA RAIL, ATTACHMENT DETAIL,
UMBRELLA L FOOT TO FRAMING,
SNR-DC-00339
6'-0"2'-4"6'-0" 2'-3" STACKED
AR-02 COMP SHINGLE - UR -
UMBRELLA L FOOT 1-Story 2X4 RAFTERS 8'-1" 24"
ULTRA RAIL, ATTACHMENT DETAIL,
UMBRELLA L FOOT TO FRAMING,
SNR-DC-00339
6'-0" 2'-4" 6'-0" 2'-3" STACKED
INSTALLERS SHALL NOTIFY ENGINEER OF ANY
POTENTIAL STRUCTURAL ISSUES OBSERVED
PRIOR TO PROCEEDING W/ INSTALLATION.
D1 - AR-01 - SCALE: 1/8" = 1'-0"
AZIM: 0°
PITCH:26°
D2 - AR-02 - SCALE: 1/8" = 1'-0"
AZIM: 90°
PITCH:26°
6' TYP
11'-3"12'11'-3"
5'-8"
6"6"
1'-8"
9'-10"
6' TYP
7'-6"
5'-8"
10'-5"12'-2"
5'
3'-4"
22'-8"11"
* IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY
REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS),
THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG
REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS
FOLLOWS:
** ALLOWABLE ATTACHMENT SPACING INDICATED ON
PLANS TO BE REDUCED BY 50%.
** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED
ON PLANS.
1'-8"
5'-8"
6'-9"
01/16/2025
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: E 2/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
FACILITY
GROUND
EXISTING 100A
MAIN BREAKER
END FED
EXISTING 100A
MAIN PANEL
100A BUS
M
100A
NEW 225 A GENERATION
AND BACKUP LOAD
PANEL
(N) 60A (PV+ESS)
BREAKER
(E) 20A PV BREAKER
4 60A
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A , 2P
120/240VAC
3
POINT OF INTERCONNECTION:CEC 705.13, GATEWAY
BREAKER AT OPPOSITE END OF BUSBAR
METER
NUMBER: 222013-456821
EQUIPMENT CHARACTERISTICS
INCLUDED IN SPEC SHEETS
NOTE: TOTAL PV BACKFEED(E+N)
= 80A USED FOR INTERCONNECTION CALCULATIONS
NEW 200A
BACKUP GATEWAY 3
1841000-X1-Y
5
Existing Inverter(s)E
SolarEdge Technologies: SE3800H-US
J-BOX
13 Hanwha Q-Cells: Q.PEAK
DUO ML-G10+ 405
EE
Existing
Knife Disconnect 30A Rated
E
E
E
(N) TESLA REMOTE
METER
SOLAR
CURRENT
TRANSFORMER
6
J-BOX
TESLA POWERWALL 3
1707000-XX-Y
TESLA:TESLA: POWERWALL 3
1707000-XX-Y
11500 WATT INVERTER
LOAD RARED DC DISCONNECT
WITH AFCI RAPID SHUTDOWN
COMPLIANT, POWER CONTROL
SYSTEM
LONGI GREEN ENERGY TECHNOLOGY
CO LTD: LR5-54HABB-400M
STRING 2 OF 6 MODULES
2 MODULES LEVEL RAPID SHUTDOWN
DEVICES
1
1
2
3 LONGI GREEN ENERGY TECHNOLOGY
CO LTD: LR5-54HABB-400M
STRING 1 OF 8 MODULES
3 MODULES LEVEL RAPID SHUTDOWN
DEVICES
(1) TESLA
POWERWALL 3
EXPANSION PACK
1807000-XX-Y
UL 9450
FACTORY
WIRING
ASSEMBLY
PV-4.0
ELECTRICAL
#ESTAMP
E
HISTORIC-526 S
Ross St3/21/2025
Inverter Calculations
Each Inverter has the following values which are calculated following these
formulas:
Inverter X:
(Continuous Load)(690.8(B)(1))
Load)(690.8(B)(1))
[((Temp Coef Voc) x (Voc)) / 100] x (Low Temp -
STC Temp) + Voc * (# Modules / String)
Inverter Powerwall 3 1707000-xx-y
Combinded Inverter Output:
Wire Calculations
Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient
temperature calculations from 310.15(B)(3)(c) and raceway fill adjustments from
310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above the
roof deck. PV Circuit conductor ampacity is constrained using the 75°C column
with the continuous duty uprating or the 90°C column with the relevant ambient
temperature and raceway fill adjustments without the continuous duty uprating
per 690.8(B), whichever results with a larger wire size. Non-PV Circuit
Conductors use the ampacity in the 75°C column or the 90°C column with the
relevant ambient temperature and raceway fill adjustments, whichever is less
(110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall
be greater than, or equal to, the continuous duty uprated current.
Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor
>= Output Current
PAGE
REV: E 02/27/25
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN/TMK #: APN: 010-134-15
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-4.2
ELECTRICAL CALCS
ALLOWABLE BACKFEED
MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING =
100A
100A ≤ 100A→ INTERCONNECTION MEETS CEC 705.13 REQUIREMENTS
E
E
HISTORIC-526 S
Ross St3/21/2025
----Inverter Calculations
Each Inverter has the following values which are calculated following these
formulas:
Inverter X:
(Continuous Load)(690.8(B)(1))
Load)(690.8(B)(1))
[((Temp Coef Voc) x (Voc)) / 100] x (Low Temp -
STC Temp) + Voc * (# Modules / String)
Inverter Powerwall 3 1707000-xx-y
Inverter Powerwall 3 1707000-xx-y
Combinded Inverter Output:
Wire Calculations
Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient
temperature calculations from 310.15(B)(3)(c) and raceway fill adjustments from
310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above the
roof deck. PV Circuit conductor ampacity is constrained using the 75°C column
with the continuous duty uprating or the 90°C column with the relevant ambient
temperature and raceway fill adjustments without the continuous duty uprating
per 690.8(B), whichever results with a larger wire size. Non-PV Circuit
Conductors use the ampacity in the 75°C column or the 90°C column with the
relevant ambient temperature and raceway fill adjustments, whichever is less
(110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall
be greater than, or equal to, the continuous duty uprated current.
Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor
>= Output Current
PAGE
REV: A 01/16/25
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN/TMK #: APN: 010-134-15
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-4.2
ELECTRICAL CALCS
ALLOWABLE BACKFEED
MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING =
100A
70A ≤ 100A→ INTERCONNECTION MEETS CEC 705.13 REQUIREMENTS
HISTORIC-526 S
Ross St3/21/2025
BACKUP LOADS
LOAD BREAKER RATING
(AMPS)LABEL DEMAND
LOAD
1 15A-1P GAR LITES 1500 VA
2 15A-1P LIGHTING/RECEPTACLES 1500 VA
3 20A-1P GAR OUTSIDE 1500 VA
4 20A-1P PLUGS 1500 VA
5 20A-1P MASTER BATH 1500 VA
6 20A-1P DISH WASHER 1500 VA
7 20A-1P DISPOSAL 1500 VA
8 20A-1P GAR PLUGS 1500 VA
9 20A-1P LIGHTS 1500 VA
10 20A-1P LIGHTING/RECEPTACLES 1500 VA
11 50A-2P SUB PANEL 9600 VA
PAGE
REV: A 1/16/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
#ESTAMP
PV-4.3
ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE
PANEL.
BACKED UP LOADS CALCULATION:
(9600VA)/ 240V = 40 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15.
THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 40 A.
(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) =
40 A X 1.25 = 50A
GATEWAY FEEDER BREAKER = 70A
50 A < 70A.
THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD.
AC WIRE SIZING FOR BACKUP LOADS PANEL
MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] =
40 A X 1.25 = 50A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X
(CONDUCTOR AMPACITY)[TABLE 310.16] =
0.91 X .5X 55A = 25.02A
TERMINAL RATING[110.14(C)] =
8 AWG, 75°C RATED =50A
25.02A < 50A TERMINAL RATING GOVERNS CONDUCTOR SIZING
40A ≤ 50A 8 AWG AMPACITY OK
THEREFORE 8 AWG IS SUFFICIENT.
BACKUP LOAD CALCS
BACKUP LOAD
CALCS
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: E 2/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
#ESTAMP
PV-4.4
PANEL SCHEDULE
MAIN
BREAKER
EXISTING 100A/100A
MAIN PANEL
100NEW 225A GENERATION AND
BACKUP LOADS PANEL
MAIN
BREAKER
FUTURE 100A/100A
MAIN PANEL
100100GATEWAY
FEEDER
BREAKER152015205020202020202020 50
STUDIO PLUGS
GAR PLUGS
LIGHTS BACK
DISH WASHER
DISPOSAL
AC
GAR OUTSIDE
LIGHTING/RECEPTACLS
LIGHTING/RECEPTACLS
GAR LITES
SUB PANEL
(E) PV
BREAKER
GAR PLUGS 15201520202020202020 50502060(E) PV
BREAKER
(E) PV
BREAKER
SUB PANEL
DISH WASHER
DISPOSAL
AC
STUDIO PLUGS
GAR PLUGS
LIGHTS BACK
GAR PLUGS
GAR LITES
LIGHTING/RECEPTACLS
GAR OUTSIDE
LIGHTING/RECEPTACLS
EXISTING 125A
SUB PANEL
151515202020202020152020202020DINING ROOM LIGHTS
KITCHEN LIGHTS
HALLWAY LIGHTS WASHING MACHINE
NORTH WALL PLUGS NORTH WALL PLUGS
REFRIGERATORDINING ROOM PLUGS
HALLWAY PLUGS
OFFICE PLUGS
GFCI
STOVE PLUGS
BEDROOM PLUGS
GUEST ROOM PLUGS
E
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: E 2/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE
PV-5.0
#ESTAMP
NOMINAL ESS VOLTAGE VAC
LABEL LOCATION:
ENERGY STORAGE SYSTEM
PER CODE(S): NEC 706.15(C), CEC 706.15(C)
120/240
520 VDCMAXIMUM ESS DC VOLTAGE:60
ENERGY STORAGE SYSTEM DISCONNECT
ENERGY STORAGE SYSTEM
PREMISES WIRING MAY REMAIN
ENERGIZED AFTER LOSS OF
UTILITY POWER
CAUTION!
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C)
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020: 705.12(B)(3)(2),
CEC 2022: 705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC
2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE
REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.
SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING
EFFECTIVE WORDS, COLORS AND SYMBOLS.
LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR
WIRING METHOD AND SHALL NOT BE HAND WRITTEN.
LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE
ENVIRONMENT INVOLVED.
SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT
SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
DO NOT COVER EXISTING MANUFACTURER LABELS.
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C)
4"
3"
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B), CEC
2022: 690.13(B)
!
INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC550
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:
690.31(D)(2)CAUTION
526 S ROSS ST, SANTA ANA, CA, 92701
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
MULTIPLE SOURCES OF POWER
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),
CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C), CEC
2022: 705.12(C)
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
48 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54
PV SYSTEM DISCONNECT
AC DISCONNECT (EXT)
ESS - PCS CONTROLLED
(E) PV EQUIPMENT
RAPID SHUTDOWN DISCONNECT LOCATION
(EXISTING SYSTEM AC DISCONNECT)
EXPANSION PACK
E
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: E 2/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE
PV-5.1
#ESTAMP
LABEL LOCATION:
BACKUP LOAD PANEL
(MAIN PANEL)
NO ADDITIONAL
LOADS TO BE
ADDED
WARNING: THIS SENSOR IS PART
OF A POWER CONTROL SYSTEM.
DO NOT REMOVE. REPLACE ONLY
WITH THE SAME TYPE AND RATING.
WARNING: THIS SENSOR IS PART
OF A POWER CONTROL SYSTEM.
DO NOT REMOVE. REPLACE ONLY
WITH THE SAME TYPE AND RATING.
REQUIREMENT: UL 1741, SECTION 206.3
LOCATION: AROUND THE CT WIRE BY CLAMP
SIZE 4.25" X 0.75"
INVERTER 1
LABEL LOCATION:
REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4
LOCATION: MAIN PANEL
SIZE: 4.25" X 1.25"
PCS CONTROLLED CURRENT SETTING: 80 A
THE MAXIMUM OUTPUT CURRENT FROM THIS
SYSTEM IS CONTROLLED ELECTRONICALLY.
REFER TO THE MANUFACTURER'S
INSTRUCTIONS FOR MORE INFORMATION.
ONLY THIS
INVERTER HAS
RAPID SHUT DOWN
E
HISTORIC-526 S
Ross St3/21/2025
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] HISTORIC-526 SRoss St3/21/2025
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 41.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) HISTORIC-526 SRoss St3/21/2025
PAGE
REV: E 2/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
CHIPPY PRINCE
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
#ESTAMP
PV-4.4
PANEL SCHEDULE
MAIN
BREAKER
EXISTING 100A/100A
MAIN PANEL
100NEW 225A GENERATION AND
BACKUP LOADS PANEL
MAIN
BREAKER
FUTURE 100A/100A
MAIN PANEL
100100GATEWAY
FEEDER
BREAKER152015205020202020202020 50
STUDIO PLUGS
GAR PLUGS
LIGHTS BACK
DISH WASHER
DISPOSAL
AC
GAR OUTSIDE
LIGHTING/RECEPTACLS
LIGHTING/RECEPTACLS
GAR LITES
SUB PANEL
(E) PV
BREAKER
GAR PLUGS 15201520202020202020 50502060(E) PV
BREAKER
(E) PV
BREAKER
SUB PANEL
DISH WASHER
DISPOSAL
AC
STUDIO PLUGS
GAR PLUGS
LIGHTS BACK
GAR PLUGS
GAR LITES
LIGHTING/RECEPTACLS
GAR OUTSIDE
LIGHTING/RECEPTACLS
EXISTING 125A
SUB PANEL
151515202020202020152020202020DINING ROOM LIGHTS
KITCHEN LIGHTS
HALLWAY LIGHTS WASHING MACHINE
NORTH WALL PLUGS NORTH WALL PLUGS
REFRIGERATORDINING ROOM PLUGS
HALLWAY PLUGS
OFFICE PLUGS
GFCI
STOVE PLUGS
BEDROOM PLUGS
GUEST ROOM PLUGS
E
HISTORIC-526 S
Ross St3/21/2025
!
"
#$$% &
!
" '() *$
' *
" +
'
,(-./)0
1'
*
#1
$
1'
#
2 $"
+)
$"
+ %
#$% & !
1'
)+
!
%
#
')
#2* $"
+1
*
$"
+
3
#
43 5
)6
57...*
57...&*
5#+#
&8
!
97
'"
*
"
1
""
%
5
#
!
)+
9
*
7
':$"
-
# ;.<2=><2?0
(1
"
+
"
+
#
" '
" '+
+
+
,22
E
F
'"
"G
H
*8 '
"
+
.Sep 16, 20205 .>-2=&>2?0
.&2=2?%!
"
1
+
&2@9=2@?2@9=2@?
+
/%-;
#
#
#'A3B1$% &0 )
0%&71C$><;;>>&<$".+ *#.
*
#
8
# ="?&.-2"=/)?=&.;2*#?
" 'D
'+#/)
*#/
*
#
# .2=.>2?
*
#
8 .>2=&;.<><2?
*
#
# &.<2=<.>>2?++
)
" ')
"
++
7
%
#
% 0
% +
+)3D
%/)0
!
%/)0
1:
!'
+
D
'+
D
)
:
+
D
)
#
)
!
)
= +
)
#
?%!
0
%!
+
HISTORIC-526 SRoss St3/21/2025
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547-2018 IEEE 1547.1-2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547-2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547-2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547-2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547-2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547-2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547-2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA-V2.0 (HECO) Part II B HIGH FREQUENCY RIDE-THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA-V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547-2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547-2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547-2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547-2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547-2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547-2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547-2018 IEEE 1547.1-2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547-2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547-2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547-2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547-2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547-2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547-2018 VOLTAGE-ACTIVE POWER (VOLT-WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547-2018 TEST FOR FREQUENCY-DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY—ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA-V2.0 (HECO) Part II C TEST FOR FREQUENCY-DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY—BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA-V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547-2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547-2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547-2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547-2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547-2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547-2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547-2018 HISTORIC-526 SRoss St3/21/2025
HISTORIC-526 S
Ross St3/21/2025
Powerwall 3
Power Everything
2024
—
Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers
can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while
participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system
behavior to meet their energy goals.
Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has
the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3
isdesignedformassproduction,fastandefcientinstallations,easysystemexpansion,andsimpleconnectiontoanyelectrical
service.
22024Powerwall 3 Datasheet
Solar Technical
Specications
Maximum Solar STC Input 20 kW
WithstandVoltage 600 V DC
PVDCInputVoltageRange 60 — 550 V DC
PVDCMPPTVoltageRange 60 — 480 V DC
MPPTs 6
Maximum Current per MPPT (Imp)13 A 5
Maximum Short Circuit Current per MPPT (Isc)15 A 5
Powerwall3 Technical Specifications
1 Typical solar shifting use case.
2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power.
3 TestedusingCECweightedefciencymethodology.
4 ThecustomerisexpectedtoprovideinternetconnectivityforPowerwall3;cellularshouldnotbeusedastheprimarymodeof
connectivity. Cellular connectivity subject to network operator service coverage and signal strength.
5 WheretheDCinputcurrentexceedstheMPPTrating,ajumpercanbeusedtocombinetwoMPPTsintoasingleinputto
intake DC current up to 26 A IMP / 30 A ISC.
Battery Technical
Specications
Nominal Battery Energy 13.5 kWh AC 2
MaximumContinuousDischargePower 11.5 kW AC
MaximumContinuousChargePower 5 kW AC
OutputPowerFactorRating 0-1(GridCodecongurable)
MaximumContinuousCurrent 48 A
Maximum Output Fault Current 10 kA
LoadStartCapability(1s)185 A LRA
PowerScalability Up to 4 Powerwall 3 units supported
SystemTechnical
Specications
ModelNumber 1707000-xx-y
NominalGridVoltage(Input&Output)120/240 VAC
GridType Split phase
Frequency 60 Hz
OvercurrentProtectionDevice 60 A
SolartoBatterytoHome/GridEfciency 89% 1,2
SolartoHome/GridEfciency 97.5% 3
SupportedIslandingDevices Gateway 3, Backup Switch, Backup Gateway 2
Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet,
Cellular (LTE/4G 4)
HardwareInterface Drycontactrelay,RapidShutdown(RSD)certiedswitch
and 2-pin connector, RS-485 for meters
AC Metering Revenue Grade (+/- 0.5%)
Protections Integrated arc fault circuit interrupter (AFCI), Isolation
MonitorInterrupter(IMI),PVRapidShutdown(RSD)using
TeslaMid-CircuitInterrupters
CustomerInterface TeslaMobileApp
Warranty 10 years
HISTORIC-526 S
Ross St3/21/2025
HISTORIC-526 S
Ross St3/21/2025
!"#!$%$&
'
(
)( *+ ,-
((* ,
. ) ./
( *
00+&1&2!!%
. .3(
4
/
*4
.
.3#!5$
/
.(
/(
671.(
.3%$&..
*8
./)(
..
4
*.
((
(.
%. .3*8
/
-)
/(
(
(..
.3 *
.3
.
( *"(
3
.3 !"$
9
$:222$&
(-.-$: 222$&88
-8(
-
.
* :;#2615--<72715.=
3 2#!5--<;2#&5.=
8 ;1215--<&2715.=3
..3 >
&2;152-<&15()/2.=!2!!?!2!:5.@<2!6?12#5--@=$: 222$:!=&2;152-<&15()/2.=$: 222$:!=12!652-< 15()/2.=!2!:5.@<62&75--@=$6=12!652-< 15()/2.=!2!?!2!&5.@<:2&?:2:5--@=$#222$ =12#152-<1!5()/2.=!2! 5.@<#2#75--@=$&=
.3
.88.3
(
3*!!:!#AB%$&B&!!!$.
(
:$(
-
+-
.
.. .
.
)
/
.. )
/
-..3
)( *
(
)( */
8 /8
/
88(
.Feb 3, 2020:!!761;!: ;: ;:
,
3
4
3 <)=2::5,3< 2#15()<==
.
)( *C
. */3.%D//
.
)( *
.
)(
//
.
--8
(/.
88 .#1$+8
.
E8
*
-
(.(.3+
.(
-8.4,.4.
/
(/.
.3
.A
8 '
-2-
./-
.3 44428#14
..32
23'$
3(
.$
(
.$/
/"C
'
-8(
.
(
.E
'*-
(/
C
%
*/
C
E
-8 ../-
.C
.
3(
..
(
.
'
.
(
.< /.
(
3
(8
=.'.-
.
((
.'.-
.
(/(
(
*/(
.
/8
/
*(.38
..
(4
. *
. *:6-. HISTORIC-526 SRoss St3/21/2025
32024Powerwall 3 Datasheet
Mechanical
Specications
Dimensions 1099x609x193mm(43.25x24x7.6in)
Weight 130 kg (287 lb)
MountingOptions Floor or wall mount
Powerwall3 Technical Specifications
Environmental
Specications
Operating Temperature –20°C to 50°C (–4°F to 122°F) 6
OperatingHumidity(RH)Up to 100%, condensing
Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non-
condensing, State of Energy (SOE): 25% initial
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
EnclosureRating NEMA3R
IngressRating IP67 (Battery & Power Electronics)
IP45 (Wiring Compartment)
PollutionRating PD3
OperatingNoise@1m < 50 db(A) typical
<62db(A)maximum
Compliance
Information
Certications UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL
1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547-
2018, IEEE 1547.1, UN 38.3
GridConnection United States
Emissions FCC Part 15 Class B
Environmental RoHS Directive 2011/65/EU
Seismic AC156, IEEE 693-2005 (high)
FireTesting Meetstheunitlevelperformancecriteria
of UL 9540A
6 Performance may be de-rated at operating temperatures above 40°C (104°F).
609 mm 193
mm
1099 mm
42024Powerwall 3 Datasheet
Electrical
Specications
Model MCI-1 MCI-2
NominalInputDCCurrentRating(IMP)13 A 13 A
Maximum Input Short Circuit Current (ISC)19 A 17 A
MaximumSystemVoltage(PVHCS)600 V DC 1000 V DC
7
Solar Shutdown Device Technical Specifications
Environmental
Specications
Operating Temperature -40°C to 50°C
(-40°F to 122°F)
-45°C to 70°C
(-49°F to 158°F)
Storage Temperature –30°C to 70°C
(–22°F to 158°F)
–30°C to 70°C
(–22°F to 158°F)
EnclosureRating NEMA4X/IP65NEMA4X/IP65
RSDModule
Performance
MaximumNumberofDevicesperString 5 5
Control PowerLineExcitation PowerLineExcitation
PassiveState Normally Open Normally Open
MaximumPowerConsumption 7 W 7 W
Warranty 25 years 25 years
—
TheSolarShutdownDeviceisaMid-CircuitInterrupter(MCI)andispartofthePVsystemrapidshutdown(RSD)functionin
accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss
of AC power.
Mechanical
Specications
ElectricalConnections MC4Connector MC4Connector
Housing Plastic Plastic
Dimensions 125x150x22mm
(5x6x1in)
173x45x22mm
(6.8x1.8x1in)
Weight 350 g (0.77 lb) 120 g (0.26 lb)
MountingOptions ZEP Home Run Clip
M4Screw(#10)
M8Bolt(5/16")
Nail / Wood screw
Wire Clip
Compliance
Information
Certications UL 1741 PVRSE, UL 3741,
PVRSA (Photovoltaic Rapid Shutdown Array)
RSDInitiationMethod ExternalSystemShutdownSwitchor
Powerwall 3 Enable Switch
7MaximumSystemVoltageislimitedbyPowerwallto600VDC.
UL3741PVHazardControl
(andPVRSA)Compatibility SeePowerwall3InstallationManual
HISTORIC-526 S
Ross St3/21/2025
52024Powerwall 3 Datasheet
Gateway 3
8 Only Eaton CSR or BWH main breakers are 25 kA rated.
Performance
Specications
ModelNumber 1841000-01-y
NominalGridVoltage 120/240 V AC
GridConguration Split phase
GridFrequency 60 Hz
ContinuousCurrent
Rating
200 A
Maximum Supply Short
Circuit Current
22 kA with Square D or
Eaton main breaker
25 kA with Eaton main
breaker 8
IECProtectiveClass Class I
Overvoltage Category Category IV
Mechanical
Specications
Dimensions 660x411x149mm
(26x16x6in)
Weight 16.3 kg (36 lb)
Mountingoptions Wall mount
Environmental
Specications
Operating Temperature –20°C to 50°C (–4°F to 122°F)
OperatingHumidity(RH)Up to 100%, condensing
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
EnclosureType NEMA3R
Compliance
Information
Certications UL 67, UL 869A, UL 916, UL 1741 PCS,
CSA 22.2 107.1, CSA 22.2 29
Emissions FCC Part 15, ICES 003
—
Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless
transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based
control, and backup operation.
411 mm
660
mm
149
mm
AC Meter Revenue accurate (+/- 0.5%)
Communication CAN
UserInterface Tesla App
BackupTransition Automatic disconnect for
seamless backup
Overcurrent
ProtectionDevice
100–200 A
Service entrance rated
Eaton CSR, BWH, or BW, or
SquareDQOMbreakers
InternalPanelboard 200 A
8-space/16 circuit breakers
Eaton BR, Siemens QP, or
SquareDHOMbreakersrated
to 10–125A
Warranty 10 years
62024Powerwall 3 Datasheet
Backup Switch
9Breakermaximumsupplyshortcircuitcurrentratingmustbeequaltoorgreaterthantheavailablefaultcurrent.
Performance
Specications
ModelNumber 1624171-xx-y
ContinuousLoadRating 200 A, 120/240 V split phase
Maximum Supply Short Circuit Current 22 kA with breaker 9
Communication CAN
AC Meter Revenue accurate (+/- 0.5%)
ExpectedServiceLife 21 years
Warranty 10 years
Mechanical
Specications
Dimensions 176x205x74mm(6.9x8.1x2.9in)
Weight 2.8 lb
MeterandSocketCompatibility ANSI Type 2S, ringless or ring type
External Service Interface Contactor manual override 10
Reset button
ConduitCompatibility 1/2-inch NPT
Environmental
Specications
Operating Temperature –40°C to 50°C (–40°F to 122°F)
Storage Temperature –40°C to 85°C (–40°F to 185°F)
EnclosureRating NEMA3R
PollutionRating PD3
Compliance
Information
SafetyStandards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65
Emissions FCC, ICES
10Manuallyoverridesthecontactorpositionduringaserviceevent.
—
The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility
meter or in a standalone meter panel downstream of the utility meter.
The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates
directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app.
204.86
74
176 mm
205 mm
74 mm
HISTORIC-526 S
Ross St3/21/2025
72024Powerwall 3 Datasheet
Backup Gateway 2
Performance
Specications
ModelNumber 1232100-xx-y
ACVoltage(Nominal)120/240 V
Feed-inType Split phase
GridFrequency 60 Hz
CurrentRating 200 A
Maximum Supply Short
Circuit Current
10 kA 11
Overcurrent Protection
Device
100 - 200 A, Service
entrance rated 9
Overvoltage Category Category IV
Internal Primary
AC Meter
Revenue accurate
(+/- 0.2%)
Internal Auxiliary
AC Meter
Revenue accurate
(+/- 2%)
Primary Connectivity Ethernet, Wi-Fi
SecondaryConnectivity Cellular (3G, LTE/4G) 12
Mechanical
Specications
Dimensions 660x411x149mm
(26x16x6in)
Weight 20.4 kg (45 lb)
Mountingoptions Wall mount,
Semi-Đushmount
Environmental
Specications
Operating Temperature –20°C to 50°C (–4°F to 122°F)
OperatingHumidity(RH)Up to 100%, condensing
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
EnclosureType NEMA3R
Compliance
Information
Certications UL 67, UL 869A, UL 916, UL 1741 PCS,
CSA 22.2 0.19, CSA 22.2 205
Emissions FCC Part 15, ICES 003
411 mm
660 mm
149
mm
11 When protected by Class J fuses, Backup Gateway 2 is
suitable for use in circuits capable of delivering not more
than 22kA symmetrical amperes.
12 Cellular connectivity subject to network operator service
coverage and signal strength.
—
Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing
seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based
control, and backup operation.
Inthissystemconguration,Powerwall3actsastheSiteController,withtheBackupGateway2SiteControllerdisabled.
UserInterface Tesla App
OperatingModes Support for solar self-
consumption, time-based
control, and backup
BackupTransition Automatic disconnect for
seamless backup
Modularity Supports up to 10 AC-
coupled Powerwalls
Optional Internal
Panelboard
200 A 6-space / 12 circuit
breakers
Siemens QP or Square D
HOMbreakersrated10-
80A or Eaton BR breakers
rated 10 - 125A
Warranty 10 years
82024Powerwall 3 Datasheet
Powerwall3 Example System Configurations
Powerwall 3 with Backup Switch
Whole Home Backup
Powerwall 3 with Gateway 3
Whole Home Backup
Powerwall 3 with Backup Gateway 2
Partial Home Backup
HISTORIC-526 S
Ross St3/21/2025
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 HISTORIC-526 SRoss St3/21/2025
Service Voltage
240
Section 220.82 Dwelling Unit
Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft:
Amps Box A (VA)
27.15 6516
Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits:
Size in VA Size in VA
1500
1500
1500
1000
600
1000
1600
Amps Box B (VA)
36.25 8700
Total VA from Parts #1 and #2 combined:Box A + Box B =15216
Total VA 15216
First 10000 VA @ 100%10000 Remaining VA @ 40%
Remaining VA =5216 5216 x 40% =2086.4 VA
Adding First 10000 VA, if possible 10000 VA
Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:12086.4 VA
Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:50.36 Amps
Part #3 - Section 220.82(C) Heating and A/C loads:
*Combine the larger loads of either the Heating or the A/C loads togther
100% of all the Heating or A/C loads in VA:0 VA
100% of all the Heating or A/C loads in Amps:0.00 A
VA Volts Amps
Parts #1 & #2 12086.4 240 50.36
Part #3 0 240 0.00
Total VA for all Parts:12,086
Totals Service/Feeder Load 50.36
Dedicated circuit Dedicated circuit
Article 220 - Dedicated Backup Panel Calculation Job Code
526 S Ross St
Santa Ana, CA 92701
109R-526VEL1
Building Square Footage VA (watts)Amps
House 2172.00 6516 27.15
Total for Part #1:
Laundry
Appliance Circuit - 1
Appliance Circuit - 2
Dishwasher
Disposal
Refrigerator
Microwave
Totals for Part #2:
Totals from all Parts
HISTORIC-526 S
Ross St3/21/2025
Section 220.82 Dwelling Unit
Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft:
Amps Box A (VA)
27.15 6516
Part #2 - Section 220.82
Size in VA Size in VA
1500 N/A
3000 N/A
1000 N/A
600 N/A
1000 N/A
1600 N/A
N/A N/A
N/A N/A
N/A N/A
N/A Amps Box B (VA)
N/A 36.25 8700
Total VA from Parts #1 and #2 combined:Box A + Box B =15216
Total VA 15216
First 10,000 VA @ 100%10000 Remaining VA @ 40%
Remaining VA =5216 5216 x 40% =2086.4 VA
Adding First 10,000 VA 10000 VA
Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:12086.4 VA
Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:50.36 Amps
Part #3 - Section 220.82 (C) Heating and A/C loads:
*Combine the larger loads of either the Heating or the A/C loads togther
100% of all the Heating or A/C loads in VA:8,160 VA
100% of all the Heating or A/C loads in Amps:34.00 A
VA Volts Amps
Parts #1 & #2 12086.4 240 50.36
Part #3 8,160 240 34.00
Total VA for all Parts:20,246
Totals Service/Feeder Load 84.36
#ESTAMP
Laundry
Appliance Circuit(s)
Dishwasher(s)
Disposal(s)
Dedicated circuit
House
Square Footage
2172
Article 220 - Service/Feeder calculation for (address):
526 S Ross St
Santa Ana, CA 92701
Building VA (watts)
6516
Amps
27.15
Job Code
109R-526VEL1
Totals from all Parts
Dedicated circuit
Total for Part #1:
Water Heater
Refrigerator(s)
Microwave(s)
Totals for Part #2:Pool Equipment
Dryer
Range
Oven
Cooktop
HISTORIC-526 S
Ross St3/21/2025
Bus Rating:100
Main Rating:100
0%0%
Itemized House and 240V Loads for Panel: (VA)
8160
Not Fed by other panels
Feeds: Panel 2 50.36
34.00
84.36
Bus Rating:225
Main Rating:70
100%100%
Itemized House and 240V Loads for Panel: (VA)
1500 1500
1500 1000
600 1000
1600
Fed by: Panel 1
50.36
50.36
Panel 1 of 2
Panel % of Sq.Ft:Panel % of 100% VA:
A/C Unit - 240V
Panel % of Sq.Ft:Panel % of 100% VA:
Load Calc: (This Panel)
Total Load Calc:
Load Calc: (This Panel)
Total Load Calc:
Panel 2 of 2
Disposal Refrigerator
Microwave
Laundry Appliance Circuit - 1
Appliance Circuit - 2 Dishwasher
HISTORIC-526 S
Ross St3/21/2025
City of Santa Ana,
I, Ruben Velasco, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar
on my residence located at 526 s ross st , SANTA ANA, CA, 92704.
SIGNATURE:___________________ DATE:__________
717 17th Street, Ste. 200 | Denver, CO 80202
Docusign Envelope ID: 42CCA612-3454-4BCD-A5E7-483DB334B4C6
1/22/2025
HISTORIC-526 S
Ross St3/21/2025
Certificate Of Completion
Envelope Id: 42CCA612-3454-4BCD-A5E7-483DB334B4C6 Status: Completed
Subject: SUNRUN URGENT NEEDED FOR PERMITS Complete with Docusign: Solar Authorization Letter.pdf
Source Envelope:
Document Pages: 1 Signatures: 1 Envelope Originator:
Certificate Pages: 5 Initials: 0 Bobby Cautela
AutoNav: Enabled
EnvelopeId Stamping: Enabled
Time Zone: (UTC-08:00) Pacific Time (US & Canada)
225 Bush Street, Suite 1400
San Francisco, CA 94104
robert.cautela@sunrun.com
IP Address: 174.65.135.37
Record Tracking
Status: Original
1/17/2025 3:45:25 PM
Holder: Bobby Cautela
robert.cautela@sunrun.com
Location: DocuSign
Signer Events Signature Timestamp
Ruben Velasco
yuyos5@aol.com
Security Level: Email, Account Authentication
(None)
Signature Adoption: Pre-selected Style
Using IP Address: 68.126.219.42
Sent: 1/17/2025 3:46:50 PM
Resent: 1/22/2025 8:47:39 AM
Viewed: 1/22/2025 4:55:34 PM
Signed: 1/22/2025 4:55:46 PM
Electronic Record and Signature Disclosure:
Accepted: 1/22/2025 4:55:34 PM
ID: fe610500-9d6d-410b-bceb-cc98b632345b
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 1/17/2025 3:46:50 PM
Certified Delivered Security Checked 1/22/2025 4:55:34 PM
Signing Complete Security Checked 1/22/2025 4:55:46 PM
Completed Security Checked 1/22/2025 4:55:46 PM
Payment Events Status Timestamps
Electronic Record and Signature Disclosure
HISTORIC-526 S
Ross St3/21/2025
CONSUMER DISCLOSURE
From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you
certain written notices or disclosures. Described below are the terms and conditions for providing
to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign)
electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY
AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION
ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND
CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE'
BUTTON AT THE BOTTOM OF THIS DOCUMENT.
Getting paper copies
At any time, you may request from us a paper copy of any record provided or made available
electronically to you by us. You will have the ability to download and print documents we send
to you through the DocuSign system during and immediately after signing session and, if you
elect to create a DocuSign signer account, you may access them for thirty (30) days after such
documents are first sent to you. After such time, if you wish for us to send you paper copies of
any such documents from our office to you, please request delivery of such paper copies from us
by following the procedure described below.
Withdrawing your consent
If you decide to receive notices and disclosures from us electronically, you may at any time
change your mind and tell us that thereafter you want to receive required notices and disclosures
only in paper format. How you must inform us of your decision to receive future notices and
disclosure in paper format and withdraw your consent to receive notices and disclosures
electronically is described below.
Consequences of changing your mind
If you elect to receive required notices and disclosures only in paper format, it will slow the
speed at which we can complete certain steps in transactions with you and delivering services to
you because we will need first to send the required notices or disclosures to you in paper format,
and then wait until we receive back from you your acknowledgment of your receipt of such
paper notices or disclosures. To indicate to us that you are changing your mind, you must
withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a
DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your
consent to receive required notices and disclosures electronically from us and you will no longer
be able to use the DocuSign system to receive required notices and consents electronically from
us or to sign electronically documents from us.
All notices and disclosures will be sent to you electronically
Unless you tell us otherwise in accordance with the procedures described herein, we will provide
electronically to you through the DocuSign system all required notices, disclosures,
authorizations, acknowledgements, and other documents that are required to be provided or made
available to you during the course of our relationship with you. To reduce the chance of you
inadvertently not receiving any notice or disclosure, we prefer to provide all of the required
notices and disclosures to you by the same method and to the same address that you have given
us. Thus, you can receive all the disclosures and notices electronically or in paper format through
the paper mail delivery system. If you do not agree with this process, please let us know as
described below. Please also see the paragraph immediately above that describes the
consequences of your electing not to receive delivery of the notices and disclosures
electronically from us.
Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM
Parties agreed to: Ruben Velasco HISTORIC-526 S
Ross St3/21/2025
How to contact Sunrun Inc.:
You may contact us to let us know of your changes as to how we may contact you electronically,
to request paper copies of certain information from us, and to withdraw your prior consent to
receive notices and disclosures electronically as follows:
To contact us by email send messages to: customercare@sunrun.com
You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105
or by phone at 1-855-478-6786.
To advise Sunrun Inc. of your new e-mail address
To let us know of a change in your e-mail address where we should send notices and disclosures
electronically to you, you must send an email message to us at customercare@sunrun.com and in
the body of such request you must state: your previous e-mail address, your new e-mail
address. We do not require any other information from you to change your email address.
In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email
address to be reflected in your DocuSign account by following the process for changing e-mail in
the DocuSign system.
To request paper copies from Sunrun Inc.
To request delivery from us of paper copies of the notices and disclosures previously provided
by us to you electronically, you must contact us by (a) sending us an e-mail to
customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San
Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request
you must state your e-mail address, full name, US Postal address, and telephone number.
To withdraw your consent with Sunrun Inc.
To inform us that you no longer want to receive future notices and disclosures in electronic
format you may:
i. decline to sign a document from within your DocuSign session, and on the subsequent
page, select the check-box indicating you wish to withdraw your consent, or you may;
ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us
at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us
at 1-855-478-6786, and in connection with your request you must state your e-mail, full
name, US Postal Address, and telephone number. We do not need any other information
from you to withdraw consent.. The consequences of your withdrawing consent for
online documents will be that transactions may take a longer time to process..
Required hardware and software
Operating
Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X
HISTORIC-526 S
Ross St3/21/2025
Browsers:
Final release versions of Internet Explorer® 6.0 or above (Windows only);
Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above
(Mac only)
PDF Reader: Acrobat® or similar software may be required to view and print PDF files
Screen
Resolution: 800 x 600 minimum
Enabled Security
Settings: Allow per session cookies
** These minimum requirements are subject to change. If these requirements change, you will be
asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and
browsers are not supported.
Notices
Any notice or other communication to be made hereunder, even if otherwise required to be in
writing under other provisions of this Consent or any other documents or agreements that have
been provided to you in connection with this Consent, may alternatively be made in an electronic
record transmitted electronically to the electronic addresses provided by you. Any notice or other
communication made in electronic form will have the same legal effect and enforceability as if
made in non-electronic form.
Acknowledging your access and consent to receive materials electronically
To confirm to us that you can access this information electronically, which will be similar to
other electronic notices and disclosures that we will provide to you, please verify that you were
able to read this electronic disclosure and that you also were able to print on paper or
electronically save this page for your future reference and access or that you were able to e-mail
this disclosure and consent to an address where you will be able to print on paper or save it for
your future reference and access. Further, if you consent to receiving notices and disclosures
exclusively in electronic format on the terms and conditions described above, please let us know
by clicking the ‘I agree’ button below.
By checking the ‘I agree’ box, I confirm that:
I can access and read and have accessed, read and understood the terms of this
ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC
CONSUMER DISCLOSURES document; and
I can print on paper the disclosure or save or send the disclosure to a place where I can
print it, for future reference and access; and
Until or unless I notify Sunrun Inc. as described above, I consent to receive from
exclusively through electronic means all notices, disclosures, authorizations,
acknowledgements, and other documents that are required to be provided or made
available to me by Sunrun Inc. during the course of my relationship with you.
Entire Agreement Provision
This agreement and the consumer disclosure statement executed by the customer in conjunction
with and simultaneously with its review and acceptance of the terms set forth herein constitute
HISTORIC-526 S
Ross St3/21/2025
the entire agreement between the parties with respect to the subject matter hereof and supersede
any prior understandings, agreements, or representations by or between the parties, written or
oral, to the extent they relate in any way to the subject matter hereof.
HISTORIC-526 S
Ross St3/21/2025
01/16/2025
RE: Structural Certification for Installation of Residential Solar
RUBEN VELASCO:526 S ROSS ST, SANTA ANA, CA, 92701
Attn: To Whom It May Concern
Design Criteria
Code 2022 California Building Code (ASCE 7-16)
Risk category II Wind Load (component and Cladding)
Roof Dead Load Dr 10 psf V 96 mph
PV Dead Load DPV 3 psf Exposure B
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
If you have any questions on the above, please do not hesitate to call.
Signed:01/16/2025
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com
Exp: 06/30/2026
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment
of the PV system to existing roof framing. From the field observation report, the roof is made of
Composition Shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the
roof was approximated to be 26 degrees.
After review and based on our structural capacity calculation, the existing roof framing has been
determined to be adequate to support the imposed loads without structural upgrades.
I certify that the PV module assembly including all attachments supporting it have been reviewed to be in
accordance with manufacturer's specifications. Capacity Calculations were done in accordance with
applicable building codes.
projects@evengineersnet.com
http://www.evengineersnet.com
HISTORIC-526 S
Ross St3/21/2025
Wind Load Cont.
96 mph ASCE 7-16 Figure 26.5-1B
B
1.0 ASCE 7-16 Sec 26.8.2
0.57 ASCE 7-16 Table 26.10-1
0.85 ASCE 7-16 Table 26.6-1
1.00 ASCE 7-16 Table 26.9-1
11.39 psf
26.0 Degrees
1.5
0.8
Uplift (W)Zone(1,2e)Zone(2r, 2n)Zone(3e)Zone(3r)
Fig. 30-3-2 GCp=-1.3 -1.7 -1.7 -1.8
Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-17.77 -23.24 -23.24 -24.61
GCp=0.6 Figure 30.3-2
P=qh(GCp)(γE)(γa)=4.51 Equation 29.4-7
Rafter Attachments: 0.6D+0.6W (CD=1.6)
Connection Check
Attachment max. spacing=6 ft
5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS
2.5 in DFL#2 Assumed
Prying Coefficient 1.4
Allowable Capacity=760 lbs
Zone Trib Width Area (ft)Uplift (lbs)Down (lbs)
Zone(1,2e)6 16.5 113.1 123.9
Zone(2r, 2n)6 16.5 142.9 123.9
Zone(3e)6 16.5 142.9 123.9
Zone(3r)6 16.5 150.3 123.9
Conservative Max=150.3 <760
2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw.
Embedment in sheading or other material does not count.
II
V=
Exposure =
1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift
governs
γE=
γa=
KZt =
qh= 0.00256KzKztKdKeV2=
Pitch =
Lag Screw Penetration=
CONNECTION IS OK
Risk Category =
KZ =
Kd =
Ke =
projects@evengineersnet.com
http://www.evengineersnet.com
HISTORIC-526 S
Ross St3/21/2025
Vertical Load Resisting System Design
Roof Framing Rafters
Snow Load Fully Exposed
pg=0 psf Ct =1.1
Ce =0.9 Is =1.0 ps = 0 psf
pf = 0 psf pfmin. = 0.0 psf 0 plf
Max Length, L =8.1 ft
Tributary Width, WT =24 in
RLL =20 psf 17.98 plf
Dr =10 psf 20 plf
PvDL =3 psf 6 plf
Load Case: DL w=26 plf
M=189 lb-ft
Mallowable = Sx x Fb'=309 lb-ft >189 lb-ft OK
Load Case: DL+RLL DL+Lr=38 plf
Mdown=276 lb-ft
Mallowable = Sx x Fb'=429 lb-ft >276 lb-ft OK
Load Case: DL+S DL+S=26 plf
Mdown=189 lb-ft
Mallowable = Sx x Fb'=412 lb-ft >189 lb-ft OK
Load Case: DL+0.6W w=31.4 plf
Mu=228 lb-ft
Mallowable = Sx x Fb' (wind)=549 lb-ft >228 lb-ft OK
Load Case: 0.6DL+0.6W w=20.2 plf
Mu=146 lb-ft
Mallowable = Sx x Fb' (wind)=549 lb-ft >146 lb-ft OK
DL+0.45W+0.75(RLL or S)29 plf
Mdown=213 lb-ft
Mallowable = Sx x Fb'=549 lb-ft >213 lb-ft OK
Member Capacity
DF-L No.2
2X4 CL CF Ci Cr
Fb =900 psi 1.0 1.3 1.0 1.15 1346 psi
Fv =180 psi N/A N/A 1.0 N/A 180 psi
E =1600000 psi N/A N/A 1.0 N/A 1600000 psi
Emin =580000 psi N/A N/A 1.0 N/A 580000 psi
Depth, d =3.5 in
Width, b =1.5 in
Cross-Sectonal Area, A =5.25 in2
Moment of Inertia, Ixx =5.35938 in4
Section Modulus, Sxx =3.0625 in3
Allowable Moment, Mall = Fb'Sxx =343.4 lb-ft DCR=Mu/Mall =0.64 < 1
Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.24 < 1
Design Value Adjusted Value
Satisfactory
Satisfactory
projects@evengineersnet.com
http://www.evengineersnet.com
HISTORIC-526 S
Ross St3/21/2025
Siesmic Loads Check
Roof Dead Load 10 psf
% or Roof with Pv 26.00%
Dpv and Racking 3 psf
Average Total Dead Load 10.8 psf
Increase in Dead Load 3.5%OK
Limits of Scope of Work and Liability
The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure
and therefore no further seismic analysis is required.
We have based our structural capacity determination on information in pictures and a drawing set titled PV
plans -RUBEN VELASCO. The analysis was according to applicable building codes, professional engineering
and design experience, opinions and judgments. The calculations produced for this structure's assessment
are only for the proposed solar panel installation referenced in the stamped plan set and were made
according to generally recognized structural analysis standards and procedures.
projects@evengineersnet.com
http://www.evengineersnet.com
HISTORIC-526 S
Ross St3/21/2025
Rev: 8/29/19
SOL-01 CBC 2016
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SUNRUN
CA CL #750184
526 S Ross St Santa Ana CA USA 92701
caitlyn Hernandez
3854005019
oc_permits@sunrun.com
1.28.25
HISTORIC-526 S
Ross St3/21/2025
PAGE
REV: F1 3/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD.SUITE A,IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
PL PL PL PL
PLPLPL PL PL PLSITE PLAN
PV-2.0
#SSTAMPSP
#ESTAMPSP
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
NOTE: ROOFTOP MODULE LEVEL RAPID
SHUTDOWN DEVICE INSTALLED PER CEC
690.12
SITE PLAN -SCALE =0'-0 3/64" = 1'-0"
(E) DETACHED
GARAGE (TYP.)
(E) PV ARRAY (TYP.)
(N) ARRAY AR-01
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
(N) ARRAY AR-02
(E) FENCE
A INV
AC AMP
SE MDAC
INV A A A AA A (E) RESIDENCE
ROOF PATHWAYS
(3' TYP)
(E) GATE (TYP.)B B B BB B S ROSS STSITE PLAN - SCALE =
(E) PV EQUIPMENT
NOTES:
RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
TOTAL ROOF SURFACE AREA: 2172.0 SQFT.
TOTAL PV ARRAY AREA(E+N): 564.72 SQ FT.
PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 (E+N)= 26%
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 26° 168.2
AR-02 26° 126.1590°
TRUE
AZIM
MAG
AZIM
348° 0°
78°
(E) DETACHED
STORAGE (TYP.)
(E) DETACHED
SHED (TYP.)
INTERIOR EQUIPMENT
SHOWN AS DASHED
POWERWALL ENERGY
STORAGE SYSTEM (ESS)
COMMUNICATION
WIRES
GROUNDING
ELECTRODE
SE
MP
SM
PM
SP
MAIN PANEL
SERVICE ENTRANCE
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
LC
LEGEND ELECTRIC VEHICLE
SUPPLY EQUPMENT
ACREL METER
IQ COMBINER BOX
ENERGY STORAGE
SYSTEMDC DISCONNECT(S)
AC DISCONNECT(S)
INVERTER(S)
SOLAREDGE METER
INV
DC
SUB-PANEL
AC
DEDICATED PV METER
SUNRUN METER
SEM PV LOAD CENTER
EV
AM
CB BP
BI 1BACKUP INTERFACE
METER ADAPTER
BACKUP LOADS PANEL
MD MICROGRID
INTERCONNECT DEVICE
MA
GENERATION PANEL GP
BACKUP GATEWAYBG
RSD
EXTERNAL
RAPID
SHUTDOWN
SWITCH
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
SP BP
RSD
F1
F1
Signed: 03/26/2025
Revision to 20185008 (issued on 3/21/25)
Revision 1 #20185512
APPROVALS:
ELECT - M. Smith
HISTORIC-526 S
Ross St4/17/2025
PAGE
REV: F1 3/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
FACILITY
GROUND
EXISTING 100A
MAIN BREAKER
END FED
EXISTING 100A
MAIN PANEL
100A BUS
M
100A
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A , 2P
120/240VAC
3
POINT OF INTERCONNECTION:CEC 705.13, GATEWAY
BREAKER AT OPPOSITE END OF BUSBAR
METER
NUMBER: 222013-456821
EQUIPMENT CHARACTERISTICS
INCLUDED IN SPEC SHEETS
NOTE: TOTAL PV BACKFEED(E+N)
= 80A USED FOR INTERCONNECTION CALCULATIONS
Existing Inverter(s)E
SolarEdge Technologies: SE3800H-US
J-BOX
13 Hanwha Q-Cells: Q.PEAK
DUO ML-G10+ 405
EE
Existing
Knife Disconnect 30A Rated
E
E
E
(N) TESLA REMOTE
METER
SOLAR
CURRENT
TRANSFORMER
J-BOX
TESLA POWERWALL 3
1707000-XX-Y
TESLA:TESLA: POWERWALL 3
1707000-XX-Y
11500 WATT INVERTER
LOAD RARED DC DISCONNECT
WITH AFCI RAPID SHUTDOWN
COMPLIANT, POWER CONTROL
SYSTEM
LONGI GREEN ENERGY TECHNOLOGY
CO LTD: LR5-54HABB-400M
STRING 2 OF 6 MODULES
2 MODULES LEVEL RAPID SHUTDOWN
DEVICES
1
1
2
3 LONGI GREEN ENERGY TECHNOLOGY
CO LTD: LR5-54HABB-400M
STRING 1 OF 8 MODULES
3 MODULES LEVEL RAPID SHUTDOWN
DEVICES
(1) TESLA
POWERWALL 3
EXPANSION PACK
1807000-XX-Y
UL 9450
FACTORY
WIRING
ASSEMBLY
NEW 200A
BACKUP GATEWAY
1841000-X1-Y
(N) INTERNAL PANELBOARD
WITH (1)60A ESS+PV BREAKER
(E) 20A EXISTING PV SYSTEM
(N) 15A TRM BREAKER
5
A
A
NEW 125A BACKUP
LOAD PANEL
RELOCATED (E) LOADS
4
FACILITY
GROUND
60A
15A
20A
6
(N) IMO PE69-3020,
DISCONNECT
SWITCH, 3P, 16A
PV-4.0
ELECTRICAL
#ESTAMP
F1
F1
F1
HISTORIC-526 S
Ross St4/17/2025
PAGE
REV: F1 3/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
#ESTAMP
PV-4.4
PANEL SCHEDULE
MAIN
BREAKER
EXISTING 100A/100A
MAIN PANEL
100NEW 125A BACKUP
LOADS PANEL
MAIN
BREAKER
FUTURE 100A/100A
MAIN PANEL
100100GATEWAY
FEEDER
BREAKER152015205020202020202020 50
STUDIO PLUGS
GAR PLUGS
LIGHTS BACK
DISH WASHER
DISPOSAL
AC
GAR OUTSIDE
LIGHTING/RECEPTACLS
LIGHTING/RECEPTACLS
GAR LITES
SUB PANEL
(E) PV
BREAKER
GAR PLUGS 20202020202020202020 5050SUB PANEL
DISH WASHER
DISPOSAL
AC
STUDIO PLUGS
GAR PLUGS
LIGHTS BACK
GAR PLUGS
GAR LITES
LIGHTING/RECEPTACLS
GAR OUTSIDE
LIGHTING/RECEPTACLS
EXISTING 125A
SUB PANEL
151515202020202020152020202020DINING ROOM LIGHTS
KITCHEN LIGHTS
HALLWAY LIGHTS WASHING MACHINE
NORTH WALL PLUGS NORTH WALL PLUGS
REFRIGERATORDINING ROOM PLUGS
HALLWAY PLUGS
OFFICE PLUGS
GFCI
STOVE PLUGS
BEDROOM PLUGS
GUEST ROOM PLUGS
200A BACKUP
GATEWAY
(N) TRM
BREAKER
(E) PV
BREAKER6020(N) ESS+PV
BREAKER
15F1
F1
HISTORIC-526 S
Ross St4/17/2025
PAGE
REV: F1 3/27/2025
RUBEN VELASCO
526 S ROSS ST, SANTA ANA, CA,
92701
PROJECT NUMBER:
109R-526VEL1
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. 7143818044
APN: 010-134-15
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE
PV-5.0
#ESTAMP
NOMINAL ESS VOLTAGE VAC
LABEL LOCATION:
ENERGY STORAGE SYSTEM
PER CODE(S): NEC 706.15(C), CEC 706.15(C)
120/240
520 VDCMAXIMUM ESS DC VOLTAGE:60
ENERGY STORAGE SYSTEM DISCONNECT
ENERGY STORAGE SYSTEM
PREMISES WIRING MAY REMAIN
ENERGIZED AFTER LOSS OF
UTILITY POWER
CAUTION!
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C)
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020: 705.12(B)(3)(2),
CEC 2022: 705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC
2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE
REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.
SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING
EFFECTIVE WORDS, COLORS AND SYMBOLS.
LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR
WIRING METHOD AND SHALL NOT BE HAND WRITTEN.
LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE
ENVIRONMENT INVOLVED.
SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT
SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
DO NOT COVER EXISTING MANUFACTURER LABELS.
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C)
4"
3"
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B), CEC
2022: 690.13(B)
!
INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC550
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:
690.31(D)(2)CAUTION
526 S ROSS ST, SANTA ANA, CA, 92701
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
MULTIPLE SOURCES OF POWER
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),
CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C), CEC
2022: 705.12(C)
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
48 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54
PV SYSTEM DISCONNECT
AC DISCONNECT (EXT)
ESS - PCS CONTROLLED
(E) PV EQUIPMENT
RAPID SHUTDOWN DISCONNECT LOCATION
(EXISTING SYSTEM AC DISCONNECT)
EXPANSION PACK
SERVICE ENTRANCE AND GATEWAY
FEEDER BREAKER DISCONNECT
BACKUP GATEWAY(EXT)
BACKUP LOADS PANEL (EXT)
PV SYSTEM(S) ARE EQUIPPED WITH
RAPID SHUTDOWN DEVICE(S)
RAPID SHUTDOWN SWITCH
SUB PANEL
F1
HISTORIC-526 S
Ross St4/17/2025