Loading...
HomeMy WebLinkAbout526 S Ross St - 101122337 & 20185008 - PlanPAGE REV: C 2/1/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD.SUITE A,IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CONT. PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUPLOAD CALCS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2022 CRC/CBC/CEBC, 7-16 ASCE & 2018 NDS, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. CEC 2022. CEC 2022. INVERTER. SYSTEM COMPLIES WITH 690.41(A). ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS 14.88 AMPS MODULE SHORT CIRCUIT CURRENT. 23.25 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)]. VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). THROUGH A WALL OR PARTITION PER 706.15(D). THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) LTD: LR5-54HABB-400M 1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh PER PW3 TOTAL ENERGY CAPACITY (IN kWh): 27kWH (MCI-2) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS BACKUP GATEWAY : (1) 200A TESLA, 1841000-01-C, ENERGY GATEWAY 3 EXISTING SYSTEM SIZE: 5.265KW DC, 3800KW AC COMBINED SYSTEM SIZE: 10.865KW DC, 26800KW AC **The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. ** Bldg #101122337 & Elect #20185008 APPROVALS: ELECT - M. Smith HISTORIC-526 S Ross St3/21/2025 PAGE REV: E 2/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PLPLPLPLPLPL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS  IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE  SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET  EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE  DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE  FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID  SHUTDOWN DEVICE INSTALLED PER CEC  690.12 SITE PLAN - SCALE = 0'-0 3/64" = 1'-0" (E) DETACHED  GARAGE (TYP.) (E) PV ARRAY (TYP.) (N) ARRAY AR-01 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) (N) ARRAY AR-02 (E) FENCE AINV AC AGP MP SE MD AC INVAAA AAA(E) RESIDENCE ROOF PATHWAYS (3' TYP) (E) GATE (TYP.)BBBBBBS ROSS STSITE PLAN - SCALE =  (E) PV EQUIPMENT NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 2172.0 SQFT.  TOTAL PV ARRAY AREA(E+N): 564.72 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 (E+N)= 26% ARRAY  PITCH PV AREA  (SQFT) AR-01 26° 168.2 AR-02 26° 126.1590° TRUE  AZIM MAG  AZIM 348°0° 78° (E) DETACHED  STORAGE (TYP.) (E) DETACHED  SHED (TYP.) INTERIOR EQUIPMENT  SHOWN AS DASHED POWERWALL ENERGY  STORAGE SYSTEM (ESS) COMMUNICATION  WIRES GROUNDING  ELECTRODE SE MP SM PM SP MAIN PANEL SERVICE ENTRANCE  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN LC LEGEND ELECTRIC VEHICLE  SUPPLY EQUPMENT ACREL METER IQ COMBINER BOX ENERGY STORAGE  SYSTEMDC DISCONNECT(S) AC DISCONNECT(S) INVERTER(S) SOLAREDGE METER INV DC SUB-PANEL AC DEDICATED PV METER SUNRUN METER SEMPV LOAD CENTER EV AM CB BP BI  1 BACKUP INTERFACE METER ADAPTER BACKUP LOADS PANEL MD MICROGRID  INTERCONNECT DEVICE MA GENERATION PANELGP BACKUP GATEWAYBG RSD EXTERNAL  RAPID SHUTDOWN  SWITCH RAIL STANDOFFS &  FOOTINGS SOLAR MODULES SP E E Signed: 03/01/2025 HISTORIC-526 S Ross St3/21/2025 PAGE REV: A 1/16/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 MOUNTING DETAIL PV-3.1 #SSTAMP UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL INSTALLED SECTION VIEW DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO RAFTERSNR-DC-00339 1 5 7 2019 NEW DETAIL 1 6 18 2019 DRO-00138 B 6 22 2023 DC002707 REV: ADATE: DNS 6 22 2023 DRAFTER:    M.AFFENTRANGER E.FERGUSON M.AFFENTRANGER Solar Mounting Solutions MJA MJA MJA BIN: 8 214" 112" 112" 158" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 516"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212" INTO STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING. REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE REFER TO SNAPNRACK INSTALLATION MANUAL FOR516"Ø HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447" STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. SNAPNRACK5 16"n UMBRELLA LAG SCREW, S.S. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL SNAPNRACK UMBRELLA FLASHING 212" MIN. EMBEDMENT INTO WOOD MEMBER MODULE HEIGHT OFF ROOF: UR-40: 338" - 438" UR-60: 4" - 5" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA LAG AND FLASHING SNAPNRACK UMBRELLA FLASHING 01/16/2025 HISTORIC-526 S Ross St3/21/2025 PAGE REV: A 1/16/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. UMBRELLA  SCREW: 2.5" MIN EMBEDMENT  INTO FRAMING PV-3.0 LAYOUT SOLAR MODULE SNAPNRACK  RACKING 4" MODULE ELEVATION DETAIL - SCALE: NTS ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max  Span OC  Spacing Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X4 RAFTERS 7'-5"24" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 6'-0"2'-4"6'-0" 2'-3" STACKED AR-02 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X4 RAFTERS 8'-1" 24" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 6'-0" 2'-4" 6'-0" 2'-3" STACKED INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED  PRIOR TO PROCEEDING W/ INSTALLATION. D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 0° PITCH:26° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 90° PITCH:26° 6' TYP 11'-3"12'11'-3" 5'-8" 6"6" 1'-8" 9'-10" 6' TYP 7'-6" 5'-8" 10'-5"12'-2" 5' 3'-4" 22'-8"11" * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY  REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS),  THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG  REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS  FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON  PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE  1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED  ON PLANS. 1'-8" 5'-8" 6'-9" 01/16/2025 HISTORIC-526 S Ross St3/21/2025 PAGE REV: E 2/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 FACILITY  GROUND EXISTING 100A MAIN BREAKER END FED EXISTING 100A MAIN PANEL 100A  BUS M 100A NEW 225 A GENERATION AND BACKUP LOAD  PANEL (N) 60A (PV+ESS)  BREAKER (E) 20A PV BREAKER      4 60A (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 POINT OF INTERCONNECTION:CEC 705.13, GATEWAY BREAKER AT OPPOSITE END OF BUSBAR METER NUMBER: 222013-456821 EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED(E+N) = 80A USED FOR INTERCONNECTION CALCULATIONS NEW 200A BACKUP GATEWAY 3 1841000-X1-Y 5 Existing Inverter(s)E SolarEdge Technologies: SE3800H-US J-BOX 13 Hanwha Q-Cells: Q.PEAK  DUO ML-G10+ 405 EE Existing Knife Disconnect 30A Rated E E E (N) TESLA REMOTE  METER SOLAR  CURRENT  TRANSFORMER 6 J-BOX TESLA POWERWALL 3  1707000-XX-Y TESLA:TESLA: POWERWALL 3  1707000-XX-Y 11500 WATT INVERTER LOAD RARED DC DISCONNECT  WITH AFCI RAPID SHUTDOWN  COMPLIANT, POWER CONTROL  SYSTEM LONGI GREEN ENERGY TECHNOLOGY  CO LTD: LR5-54HABB-400M STRING 2 OF 6 MODULES 2 MODULES LEVEL RAPID SHUTDOWN  DEVICES 1 1 2 3 LONGI GREEN ENERGY TECHNOLOGY  CO LTD: LR5-54HABB-400M STRING 1 OF 8 MODULES 3 MODULES LEVEL RAPID SHUTDOWN  DEVICES (1) TESLA POWERWALL 3 EXPANSION PACK  1807000-XX-Y UL 9450 FACTORY WIRING  ASSEMBLY PV-4.0 ELECTRICAL #ESTAMP E HISTORIC-526 S Ross St3/21/2025 Inverter Calculations Each Inverter has the following values which are calculated following these formulas: Inverter X: (Continuous Load)(690.8(B)(1)) Load)(690.8(B)(1)) [((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc * (# Modules / String) Inverter Powerwall 3 1707000-xx-y Combinded Inverter Output: Wire Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit Conductors use the ampacity in the 75°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current PAGE REV: E 02/27/25 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN/TMK #: APN: 010-134-15 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.2 ELECTRICAL CALCS ALLOWABLE BACKFEED MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = 100A 100A ≤ 100A→ INTERCONNECTION MEETS CEC 705.13 REQUIREMENTS E E HISTORIC-526 S Ross St3/21/2025 ----Inverter Calculations Each Inverter has the following values which are calculated following these formulas: Inverter X: (Continuous Load)(690.8(B)(1)) Load)(690.8(B)(1)) [((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc * (# Modules / String) Inverter Powerwall 3 1707000-xx-y Inverter Powerwall 3 1707000-xx-y Combinded Inverter Output: Wire Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit Conductors use the ampacity in the 75°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current PAGE REV: A 01/16/25 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN/TMK #: APN: 010-134-15 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.2 ELECTRICAL CALCS ALLOWABLE BACKFEED MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = 100A 70A ≤ 100A→ INTERCONNECTION MEETS CEC 705.13 REQUIREMENTS HISTORIC-526 S Ross St3/21/2025 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL DEMAND  LOAD 1 15A-1P GAR LITES 1500 VA 2 15A-1P LIGHTING/RECEPTACLES 1500 VA 3 20A-1P GAR OUTSIDE 1500 VA 4 20A-1P PLUGS 1500 VA 5 20A-1P MASTER BATH 1500 VA 6 20A-1P DISH WASHER 1500 VA 7 20A-1P DISPOSAL 1500 VA 8 20A-1P GAR PLUGS 1500 VA 9 20A-1P LIGHTS 1500 VA 10 20A-1P LIGHTING/RECEPTACLES 1500 VA 11 50A-2P SUB PANEL 9600 VA PAGE REV: A 1/16/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP PV-4.3 ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE  PANEL. BACKED UP LOADS CALCULATION: (9600VA)/ 240V = 40 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 40 A. (MAX LOADS OUTPUT) X (CONTINUOUS LOADS) =  40 A X 1.25 = 50A GATEWAY FEEDER BREAKER = 70A 50 A < 70A. THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. AC WIRE SIZING FOR BACKUP LOADS PANEL MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 40 A X 1.25 = 50A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X .5X 55A = 25.02A TERMINAL RATING[110.14(C)] = 8 AWG, 75°C RATED =50A 25.02A < 50A   TERMINAL RATING GOVERNS CONDUCTOR SIZING 40A ≤ 50A  8 AWG AMPACITY OK THEREFORE 8 AWG IS SUFFICIENT.      BACKUP LOAD CALCS BACKUP LOAD  CALCS HISTORIC-526 S Ross St3/21/2025 PAGE REV: E 2/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP PV-4.4 PANEL SCHEDULE MAIN  BREAKER EXISTING 100A/100A  MAIN PANEL 100NEW 225A GENERATION AND  BACKUP LOADS PANEL MAIN  BREAKER FUTURE 100A/100A  MAIN PANEL 100100GATEWAY  FEEDER  BREAKER152015205020202020202020 50 STUDIO PLUGS GAR PLUGS LIGHTS BACK DISH WASHER DISPOSAL AC GAR OUTSIDE LIGHTING/RECEPTACLS LIGHTING/RECEPTACLS GAR LITES SUB PANEL (E) PV  BREAKER GAR PLUGS 15201520202020202020 50502060(E) PV  BREAKER (E) PV  BREAKER SUB PANEL DISH WASHER DISPOSAL AC STUDIO PLUGS GAR PLUGS LIGHTS BACK GAR PLUGS GAR LITES LIGHTING/RECEPTACLS GAR OUTSIDE LIGHTING/RECEPTACLS EXISTING 125A  SUB PANEL 151515202020202020152020202020DINING ROOM LIGHTS KITCHEN LIGHTS HALLWAY LIGHTS WASHING MACHINE NORTH WALL PLUGS NORTH WALL PLUGS REFRIGERATORDINING ROOM PLUGS HALLWAY PLUGS OFFICE PLUGS GFCI STOVE PLUGS BEDROOM PLUGS GUEST ROOM PLUGS E HISTORIC-526 S Ross St3/21/2025 PAGE REV: E 2/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): NEC 706.15(C), CEC 706.15(C) 120/240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC  2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE  REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING  EFFECTIVE WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR  WIRING METHOD AND SHALL NOT BE HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE  ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT  SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2)CAUTION  526 S ROSS ST, SANTA ANA, CA, 92701 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT AC DISCONNECT (EXT) ESS - PCS CONTROLLED (E) PV EQUIPMENT  RAPID SHUTDOWN DISCONNECT LOCATION  (EXISTING SYSTEM AC DISCONNECT) EXPANSION PACK E HISTORIC-526 S Ross St3/21/2025 PAGE REV: E 2/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.1 #ESTAMP LABEL LOCATION: BACKUP LOAD PANEL (MAIN PANEL) NO ADDITIONAL  LOADS TO BE  ADDED WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE  BY CLAMP SIZE 4.25" X 0.75" INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING:  80 A   THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. ONLY THIS  INVERTER HAS  RAPID SHUT DOWN E HISTORIC-526 S Ross St3/21/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] HISTORIC-526 SRoss St3/21/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 41.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) HISTORIC-526 SRoss St3/21/2025 PAGE REV: E 2/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP PV-4.4 PANEL SCHEDULE MAIN  BREAKER EXISTING 100A/100A  MAIN PANEL 100NEW 225A GENERATION AND  BACKUP LOADS PANEL MAIN  BREAKER FUTURE 100A/100A  MAIN PANEL 100100GATEWAY  FEEDER  BREAKER152015205020202020202020 50 STUDIO PLUGS GAR PLUGS LIGHTS BACK DISH WASHER DISPOSAL AC GAR OUTSIDE LIGHTING/RECEPTACLS LIGHTING/RECEPTACLS GAR LITES SUB PANEL (E) PV  BREAKER GAR PLUGS 15201520202020202020 50502060(E) PV  BREAKER (E) PV  BREAKER SUB PANEL DISH WASHER DISPOSAL AC STUDIO PLUGS GAR PLUGS LIGHTS BACK GAR PLUGS GAR LITES LIGHTING/RECEPTACLS GAR OUTSIDE LIGHTING/RECEPTACLS EXISTING 125A  SUB PANEL 151515202020202020152020202020DINING ROOM LIGHTS KITCHEN LIGHTS HALLWAY LIGHTS WASHING MACHINE NORTH WALL PLUGS NORTH WALL PLUGS REFRIGERATORDINING ROOM PLUGS HALLWAY PLUGS OFFICE PLUGS GFCI STOVE PLUGS BEDROOM PLUGS GUEST ROOM PLUGS E HISTORIC-526 S Ross St3/21/2025                    !  "  # $$% &  !  " '() *$ ' *  " +  ' ,(-./)0  1'     * #1  $       1'  #    2 $" +)  $" + %   #$% & ! 1' )+  ! %     #    ')      #2* $" +1   *  $" +      3 # 43 5 )6 57...*  57...&* 5#+# &8 ! 9 7 '" *     "   1  " " %    5  # !    )+  9  *    7 ':$" - # ;.<2=><2?0   (1           "   +    "  + #  " '  " '+  +  +    ,22  E  F  '"  "G         H *8 '  "   +    .Sep 16, 20205 .>-2=&>2?0  .&2=2?%!  "   1    +  &2@9=2@?2@9=2@?   +  /%-; #  #   #'A3B1$% &0  )  0%&71C$><;;>>&<$".+ *#. * # 8 # =" ?&.-2"=/)?=&.;2*#?  " 'D  '+#/) *#/  * #  # .2=.>2? * # 8 .>2=&;.<><2? * #  # &.<2=<.>>2?++ )  " ')  " ++   7   %   # %  0   %  + +)3D %/)0  !   %/)0   1: !' + D  '+ D ) :  + D   ) #   )     !   )   = +  ) #   ?%!  0    %!  + HISTORIC-526 SRoss St3/21/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547-2018 IEEE 1547.1-2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547-2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547-2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547-2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547-2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547-2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547-2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA-V2.0 (HECO) Part II B HIGH FREQUENCY RIDE-THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA-V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547-2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547-2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547-2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547-2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547-2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547-2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547-2018 IEEE 1547.1-2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547-2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547-2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547-2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547-2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547-2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547-2018 VOLTAGE-ACTIVE POWER (VOLT-WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547-2018 TEST FOR FREQUENCY-DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY—ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA-V2.0 (HECO) Part II C TEST FOR FREQUENCY-DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY—BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA-V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547-2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547-2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547-2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547-2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547-2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547-2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547-2018 HISTORIC-526 SRoss St3/21/2025 HISTORIC-526 S Ross St3/21/2025 Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 isdesignedformassproduction,fastandef𿿿cientinstallations,easysystemexpansion,andsimpleconnectiontoanyelectrical service. 22024Powerwall 3 Datasheet Solar Technical Speci￿cations Maximum Solar STC Input 20 kW WithstandVoltage 600 V DC PVDCInputVoltageRange 60 — 550 V DC PVDCMPPTVoltageRange 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (Imp)13 A 5 Maximum Short Circuit Current per MPPT (Isc)15 A 5 Powerwall3 Technical Specifications 1 Typical solar shifting use case. 2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. 3 TestedusingCECweightedef𿿿ciencymethodology. 4 ThecustomerisexpectedtoprovideinternetconnectivityforPowerwall3;cellularshouldnotbeusedastheprimarymodeof connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 WheretheDCinputcurrentexceedstheMPPTrating,ajumpercanbeusedtocombinetwoMPPTsintoasingleinputto intake DC current up to 26 A IMP / 30 A ISC. Battery Technical Speci￿cations Nominal Battery Energy 13.5 kWh AC 2 MaximumContinuousDischargePower 11.5 kW AC MaximumContinuousChargePower 5 kW AC OutputPowerFactorRating 0-1(GridCodecon𿿿gurable) MaximumContinuousCurrent 48 A Maximum Output Fault Current 10 kA LoadStartCapability(1s)185 A LRA PowerScalability Up to 4 Powerwall 3 units supported SystemTechnical Speci￿cations ModelNumber 1707000-xx-y NominalGridVoltage(Input&Output)120/240 VAC GridType Split phase Frequency 60 Hz OvercurrentProtectionDevice 60 A SolartoBatterytoHome/GridEf￿ciency 89% 1,2 SolartoHome/GridEf￿ciency 97.5% 3 SupportedIslandingDevices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4) HardwareInterface Drycontactrelay,RapidShutdown(RSD)certi𿿿edswitch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation MonitorInterrupter(IMI),PVRapidShutdown(RSD)using TeslaMid-CircuitInterrupters CustomerInterface TeslaMobileApp Warranty 10 years HISTORIC-526 S Ross St3/21/2025 HISTORIC-526 S Ross St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eb 3, 2020:!!761;!: ;: ;: , 3 4 3 <) =2::5,3< 2#15()<== . )( *C . */3.%D//  . )( * . )( //    . --8  (/. 88  .#1$+  8  . E8 *  - ( .(.3+  .( -8. 4   ,.4.   / (/.     .3 .A 8 '  -2- ./- .3 44428#14 ..3 2 23'$  3( .$  (  .$ / /"C   ' -8( .  (  .E '*- (/ C % */ C  E -8 ../- .C  .  3( . .  (  .  '  .  (  .< / . ( 3 ( 8 =.'.- . ( (   .'.- . (/( (  */( . / 8 / *(.38  . .    (4  . *  . *:6-. HISTORIC-526 SRoss St3/21/2025 32024Powerwall 3 Datasheet Mechanical Speci￿cations Dimensions 1099x609x193mm(43.25x24x7.6in) Weight 130 kg (287 lb) MountingOptions Floor or wall mount Powerwall3 Technical Specifications Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 OperatingHumidity(RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated EnclosureRating NEMA3R IngressRating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) PollutionRating PD3 OperatingNoise@1m < 50 db(A) typical <62db(A)maximum Compliance Information Certi￿cations UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 GridConnection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) FireTesting Meetstheunitlevelperformancecriteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 193 mm 1099 mm 42024Powerwall 3 Datasheet Electrical Speci￿cations Model MCI-1 MCI-2 NominalInputDCCurrentRating(IMP)13 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A MaximumSystemVoltage(PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Speci￿cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) EnclosureRating NEMA4X/IP65NEMA4X/IP65 RSDModule Performance MaximumNumberofDevicesperString 5 5 Control PowerLineExcitation PowerLineExcitation PassiveState Normally Open Normally Open MaximumPowerConsumption 7 W 7 W Warranty 25 years 25 years — TheSolarShutdownDeviceisaMid-CircuitInterrupter(MCI)andispartofthePVsystemrapidshutdown(RSD)functionin accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Speci￿cations ElectricalConnections MC4Connector MC4Connector Housing Plastic Plastic Dimensions 125x150x22mm (5x6x1in) 173x45x22mm (6.8x1.8x1in) Weight 350 g (0.77 lb) 120 g (0.26 lb) MountingOptions ZEP Home Run Clip M4Screw(#10) M8Bolt(5/16") Nail / Wood screw Wire Clip Compliance Information Certi￿cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSDInitiationMethod ExternalSystemShutdownSwitchor Powerwall 3 Enable Switch 7MaximumSystemVoltageislimitedbyPowerwallto600VDC. UL3741PVHazardControl (andPVRSA)Compatibility SeePowerwall3InstallationManual HISTORIC-526 S Ross St3/21/2025 52024Powerwall 3 Datasheet Gateway 3 8 Only Eaton CSR or BWH main breakers are 25 kA rated. Performance Speci￿cations ModelNumber 1841000-01-y NominalGridVoltage 120/240 V AC GridCon￿guration Split phase GridFrequency 60 Hz ContinuousCurrent Rating 200 A Maximum Supply Short Circuit Current 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker 8 IECProtectiveClass Class I Overvoltage Category Category IV Mechanical Speci￿cations Dimensions 660x411x149mm (26x16x6in) Weight 16.3 kg (36 lb) Mountingoptions Wall mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) OperatingHumidity(RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated EnclosureType NEMA3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 107.1, CSA 22.2 29 Emissions FCC Part 15, ICES 003 — Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based control, and backup operation. 411 mm 660 mm 149 mm AC Meter Revenue accurate (+/- 0.5%) Communication CAN UserInterface Tesla App BackupTransition Automatic disconnect for seamless backup Overcurrent ProtectionDevice 100–200 A Service entrance rated Eaton CSR, BWH, or BW, or SquareDQOMbreakers InternalPanelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or SquareDHOMbreakersrated to 10–125A Warranty 10 years 62024Powerwall 3 Datasheet Backup Switch 9Breakermaximumsupplyshortcircuitcurrentratingmustbeequaltoorgreaterthantheavailablefaultcurrent. Performance Speci￿cations ModelNumber 1624171-xx-y ContinuousLoadRating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 9 Communication CAN AC Meter Revenue accurate (+/- 0.5%) ExpectedServiceLife 21 years Warranty 10 years Mechanical Speci￿cations Dimensions 176x205x74mm(6.9x8.1x2.9in) Weight 2.8 lb MeterandSocketCompatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override 10 Reset button ConduitCompatibility 1/2-inch NPT Environmental Speci￿cations Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) EnclosureRating NEMA3R PollutionRating PD3 Compliance Information SafetyStandards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 Emissions FCC, ICES 10Manuallyoverridesthecontactorpositionduringaserviceevent. — The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 204.86 74 176 mm 205 mm 74 mm HISTORIC-526 S Ross St3/21/2025 72024Powerwall 3 Datasheet Backup Gateway 2 Performance Speci￿cations ModelNumber 1232100-xx-y ACVoltage(Nominal)120/240 V Feed-inType Split phase GridFrequency 60 Hz CurrentRating 200 A Maximum Supply Short Circuit Current 10 kA 11 Overcurrent Protection Device 100 - 200 A, Service entrance rated 9 Overvoltage Category Category IV Internal Primary AC Meter Revenue accurate (+/- 0.2%) Internal Auxiliary AC Meter Revenue accurate (+/- 2%) Primary Connectivity Ethernet, Wi-Fi SecondaryConnectivity Cellular (3G, LTE/4G) 12 Mechanical Speci￿cations Dimensions 660x411x149mm (26x16x6in) Weight 20.4 kg (45 lb) Mountingoptions Wall mount, Semi-Đushmount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) OperatingHumidity(RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated EnclosureType NEMA3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 411 mm 660 mm 149 mm 11 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 12 Cellular connectivity subject to network operator service coverage and signal strength. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. Inthissystemcon𿿿guration,Powerwall3actsastheSiteController,withtheBackupGateway2SiteControllerdisabled. UserInterface Tesla App OperatingModes Support for solar self- consumption, time-based control, and backup BackupTransition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOMbreakersrated10- 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 82024Powerwall 3 Datasheet Powerwall3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup HISTORIC-526 S Ross St3/21/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 HISTORIC-526 SRoss St3/21/2025 Service Voltage 240 Section 220.82 Dwelling Unit Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 27.15 6516 Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 1500 1500 1000 600 1000 1600 Amps Box B (VA) 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =15216 Total VA 15216 First 10000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =5216 5216 x 40% =2086.4 VA Adding First 10000 VA, if possible 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:12086.4 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:50.36 Amps Part #3 - Section 220.82(C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:0 VA 100% of all the Heating or A/C loads in Amps:0.00 A VA Volts Amps Parts #1 & #2 12086.4 240 50.36 Part #3 0 240 0.00 Total VA for all Parts:12,086 Totals Service/Feeder Load 50.36 Dedicated circuit Dedicated circuit Article 220 - Dedicated Backup Panel Calculation Job Code 526 S Ross St Santa Ana, CA 92701 109R-526VEL1 Building Square Footage VA (watts)Amps House 2172.00 6516 27.15 Total for Part #1: Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Totals for Part #2: Totals from all Parts HISTORIC-526 S Ross St3/21/2025 Section 220.82 Dwelling Unit Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 27.15 6516 Part #2 - Section 220.82 Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A N/A N/A N/A N/A N/A N/A N/A Amps Box B (VA) N/A 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =15216 Total VA 15216 First 10,000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =5216 5216 x 40% =2086.4 VA Adding First 10,000 VA 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:12086.4 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:50.36 Amps Part #3 - Section 220.82 (C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:8,160 VA 100% of all the Heating or A/C loads in Amps:34.00 A VA Volts Amps Parts #1 & #2 12086.4 240 50.36 Part #3 8,160 240 34.00 Total VA for all Parts:20,246 Totals Service/Feeder Load 84.36 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 2172 Article 220 - Service/Feeder calculation for (address): 526 S Ross St Santa Ana, CA 92701 Building VA (watts) 6516 Amps 27.15 Job Code 109R-526VEL1 Totals from all Parts Dedicated circuit Total for Part #1: Water Heater Refrigerator(s) Microwave(s) Totals for Part #2:Pool Equipment Dryer Range Oven Cooktop HISTORIC-526 S Ross St3/21/2025 Bus Rating:100 Main Rating:100 0%0% Itemized House and 240V Loads for Panel: (VA) 8160 Not Fed by other panels Feeds: Panel 2 50.36 34.00 84.36 Bus Rating:225 Main Rating:70 100%100% Itemized House and 240V Loads for Panel: (VA) 1500 1500 1500 1000 600 1000 1600 Fed by: Panel 1 50.36 50.36 Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: A/C Unit - 240V Panel % of Sq.Ft:Panel % of 100% VA: Load Calc: (This Panel) Total Load Calc: Load Calc: (This Panel) Total Load Calc: Panel 2 of 2 Disposal Refrigerator Microwave Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher HISTORIC-526 S Ross St3/21/2025 City of Santa Ana, I, Ruben Velasco, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar on my residence located at 526 s ross st , SANTA ANA, CA, 92704. SIGNATURE:___________________ DATE:__________ 717 17th Street, Ste. 200 | Denver, CO 80202  Docusign Envelope ID: 42CCA612-3454-4BCD-A5E7-483DB334B4C6 1/22/2025 HISTORIC-526 S Ross St3/21/2025 Certificate Of Completion Envelope Id: 42CCA612-3454-4BCD-A5E7-483DB334B4C6 Status: Completed Subject: SUNRUN URGENT NEEDED FOR PERMITS Complete with Docusign: Solar Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Bobby Cautela AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 robert.cautela@sunrun.com IP Address: 174.65.135.37 Record Tracking Status: Original 1/17/2025 3:45:25 PM Holder: Bobby Cautela robert.cautela@sunrun.com Location: DocuSign Signer Events Signature Timestamp Ruben Velasco yuyos5@aol.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 68.126.219.42 Sent: 1/17/2025 3:46:50 PM Resent: 1/22/2025 8:47:39 AM Viewed: 1/22/2025 4:55:34 PM Signed: 1/22/2025 4:55:46 PM Electronic Record and Signature Disclosure: Accepted: 1/22/2025 4:55:34 PM ID: fe610500-9d6d-410b-bceb-cc98b632345b In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 1/17/2025 3:46:50 PM Certified Delivered Security Checked 1/22/2025 4:55:34 PM Signing Complete Security Checked 1/22/2025 4:55:46 PM Completed Security Checked 1/22/2025 4:55:46 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure HISTORIC-526 S Ross St3/21/2025 CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Ruben Velasco HISTORIC-526 S Ross St3/21/2025 How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X HISTORIC-526 S Ross St3/21/2025 Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute HISTORIC-526 S Ross St3/21/2025 the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. HISTORIC-526 S Ross St3/21/2025 01/16/2025 RE: Structural Certification for Installation of Residential Solar RUBEN VELASCO:526 S ROSS ST, SANTA ANA, CA, 92701 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 96 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Signed:01/16/2025 Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2026 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition Shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was approximated to be 26 degrees. After review and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with manufacturer's specifications. Capacity Calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com HISTORIC-526 S Ross St3/21/2025 Wind Load Cont. 96 mph ASCE 7-16 Figure 26.5-1B B 1.0 ASCE 7-16 Sec 26.8.2 0.57 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 1.00 ASCE 7-16 Table 26.9-1 11.39 psf 26.0 Degrees 1.5 0.8 Uplift (W)Zone(1,2e)Zone(2r, 2n)Zone(3e)Zone(3r) Fig. 30-3-2 GCp=-1.3 -1.7 -1.7 -1.8 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-17.77 -23.24 -23.24 -24.61 GCp=0.6 Figure 30.3-2 P=qh(GCp)(γE)(γa)=4.51 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing=6 ft 5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS 2.5 in DFL#2 Assumed Prying Coefficient 1.4 Allowable Capacity=760 lbs Zone Trib Width Area (ft)Uplift (lbs)Down (lbs) Zone(1,2e)6 16.5 113.1 123.9 Zone(2r, 2n)6 16.5 142.9 123.9 Zone(3e)6 16.5 142.9 123.9 Zone(3r)6 16.5 150.3 123.9 Conservative Max=150.3 <760 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration= CONNECTION IS OK Risk Category = KZ = Kd = Ke = projects@evengineersnet.com http://www.evengineersnet.com HISTORIC-526 S Ross St3/21/2025 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg=0 psf Ct =1.1 Ce =0.9 Is =1.0 ps = 0 psf pf = 0 psf pfmin. = 0.0 psf 0 plf Max Length, L =8.1 ft Tributary Width, WT =24 in RLL =20 psf 17.98 plf Dr =10 psf 20 plf PvDL =3 psf 6 plf Load Case: DL w=26 plf M=189 lb-ft Mallowable = Sx x Fb'=309 lb-ft >189 lb-ft OK Load Case: DL+RLL DL+Lr=38 plf Mdown=276 lb-ft Mallowable = Sx x Fb'=429 lb-ft >276 lb-ft OK Load Case: DL+S DL+S=26 plf Mdown=189 lb-ft Mallowable = Sx x Fb'=412 lb-ft >189 lb-ft OK Load Case: DL+0.6W w=31.4 plf Mu=228 lb-ft Mallowable = Sx x Fb' (wind)=549 lb-ft >228 lb-ft OK Load Case: 0.6DL+0.6W w=20.2 plf Mu=146 lb-ft Mallowable = Sx x Fb' (wind)=549 lb-ft >146 lb-ft OK DL+0.45W+0.75(RLL or S)29 plf Mdown=213 lb-ft Mallowable = Sx x Fb'=549 lb-ft >213 lb-ft OK Member Capacity DF-L No.2 2X4 CL CF Ci Cr Fb =900 psi 1.0 1.3 1.0 1.15 1346 psi Fv =180 psi N/A N/A 1.0 N/A 180 psi E =1600000 psi N/A N/A 1.0 N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 580000 psi Depth, d =3.5 in Width, b =1.5 in Cross-Sectonal Area, A =5.25 in2 Moment of Inertia, Ixx =5.35938 in4 Section Modulus, Sxx =3.0625 in3 Allowable Moment, Mall = Fb'Sxx =343.4 lb-ft DCR=Mu/Mall =0.64 < 1 Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.24 < 1 Design Value Adjusted Value Satisfactory Satisfactory projects@evengineersnet.com http://www.evengineersnet.com HISTORIC-526 S Ross St3/21/2025 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 26.00% Dpv and Racking 3 psf Average Total Dead Load 10.8 psf Increase in Dead Load 3.5%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -RUBEN VELASCO. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com HISTORIC-526 S Ross St3/21/2025 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST SUNRUN CA CL #750184 526 S Ross St Santa Ana CA USA 92701 caitlyn Hernandez 3854005019 oc_permits@sunrun.com 1.28.25 HISTORIC-526 S Ross St3/21/2025 PAGE REV: F1 3/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-526VEL1 SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD.SUITE A,IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PLPLPL PL PL PLSITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED PER CEC 690.12 SITE PLAN -SCALE =0'-0 3/64" = 1'-0" (E) DETACHED GARAGE (TYP.) (E) PV ARRAY (TYP.) (N) ARRAY AR-01 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) (N) ARRAY AR-02 (E) FENCE A INV AC AMP SE MDAC INV A A A AA A (E) RESIDENCE ROOF PATHWAYS (3' TYP) (E) GATE (TYP.)B B B BB B S ROSS STSITE PLAN - SCALE = (E) PV EQUIPMENT NOTES: RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: TOTAL ROOF SURFACE AREA: 2172.0 SQFT. TOTAL PV ARRAY AREA(E+N): 564.72 SQ FT. PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 (E+N)= 26% ARRAY PITCH PV AREA (SQFT) AR-01 26° 168.2 AR-02 26° 126.1590° TRUE AZIM MAG AZIM 348° 0° 78° (E) DETACHED STORAGE (TYP.) (E) DETACHED SHED (TYP.) INTERIOR EQUIPMENT SHOWN AS DASHED POWERWALL ENERGY STORAGE SYSTEM (ESS) COMMUNICATION WIRES GROUNDING ELECTRODE SE MP SM PM SP MAIN PANEL SERVICE ENTRANCE SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN LC LEGEND ELECTRIC VEHICLE SUPPLY EQUPMENT ACREL METER IQ COMBINER BOX ENERGY STORAGE SYSTEMDC DISCONNECT(S) AC DISCONNECT(S) INVERTER(S) SOLAREDGE METER INV DC SUB-PANEL AC DEDICATED PV METER SUNRUN METER SEM PV LOAD CENTER EV AM CB BP BI 1BACKUP INTERFACE METER ADAPTER BACKUP LOADS PANEL MD MICROGRID INTERCONNECT DEVICE MA GENERATION PANEL GP BACKUP GATEWAYBG RSD EXTERNAL RAPID SHUTDOWN SWITCH RAIL STANDOFFS & FOOTINGS SOLAR MODULES SP BP RSD F1 F1 Signed: 03/26/2025 Revision to 20185008 (issued on 3/21/25) Revision 1 #20185512 APPROVALS: ELECT - M. Smith HISTORIC-526 S Ross St4/17/2025 PAGE REV: F1 3/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 FACILITY  GROUND EXISTING 100A MAIN BREAKER END FED EXISTING 100A MAIN PANEL 100A  BUS M 100A (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 POINT OF INTERCONNECTION:CEC 705.13, GATEWAY BREAKER AT OPPOSITE END OF BUSBAR METER NUMBER: 222013-456821 EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED(E+N) = 80A USED FOR INTERCONNECTION CALCULATIONS Existing Inverter(s)E SolarEdge Technologies: SE3800H-US J-BOX 13 Hanwha Q-Cells: Q.PEAK  DUO ML-G10+ 405 EE Existing Knife Disconnect 30A Rated E E E (N) TESLA REMOTE  METER SOLAR  CURRENT  TRANSFORMER J-BOX TESLA POWERWALL 3  1707000-XX-Y TESLA:TESLA: POWERWALL 3  1707000-XX-Y 11500 WATT INVERTER LOAD RARED DC DISCONNECT  WITH AFCI RAPID SHUTDOWN  COMPLIANT, POWER CONTROL  SYSTEM LONGI GREEN ENERGY TECHNOLOGY  CO LTD: LR5-54HABB-400M STRING 2 OF 6 MODULES 2 MODULES LEVEL RAPID SHUTDOWN  DEVICES 1 1 2 3 LONGI GREEN ENERGY TECHNOLOGY  CO LTD: LR5-54HABB-400M STRING 1 OF 8 MODULES 3 MODULES LEVEL RAPID SHUTDOWN  DEVICES (1) TESLA POWERWALL 3 EXPANSION PACK  1807000-XX-Y UL 9450 FACTORY WIRING  ASSEMBLY NEW 200A BACKUP GATEWAY 1841000-X1-Y (N) INTERNAL PANELBOARD WITH (1)60A ESS+PV BREAKER (E) 20A EXISTING PV SYSTEM (N) 15A TRM BREAKER 5 A A NEW 125A BACKUP LOAD PANEL RELOCATED (E) LOADS 4 FACILITY  GROUND 60A 15A 20A 6 (N) IMO PE69-3020,  DISCONNECT  SWITCH, 3P, 16A PV-4.0 ELECTRICAL #ESTAMP F1 F1 F1 HISTORIC-526 S Ross St4/17/2025 PAGE REV: F1 3/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP PV-4.4 PANEL SCHEDULE MAIN  BREAKER EXISTING 100A/100A  MAIN PANEL 100NEW 125A BACKUP  LOADS PANEL MAIN  BREAKER FUTURE 100A/100A  MAIN PANEL 100100GATEWAY  FEEDER  BREAKER152015205020202020202020 50 STUDIO PLUGS GAR PLUGS LIGHTS BACK DISH WASHER DISPOSAL AC GAR OUTSIDE LIGHTING/RECEPTACLS LIGHTING/RECEPTACLS GAR LITES SUB PANEL (E) PV  BREAKER GAR PLUGS 20202020202020202020 5050SUB PANEL DISH WASHER DISPOSAL AC STUDIO PLUGS GAR PLUGS LIGHTS BACK GAR PLUGS GAR LITES LIGHTING/RECEPTACLS GAR OUTSIDE LIGHTING/RECEPTACLS EXISTING 125A  SUB PANEL 151515202020202020152020202020DINING ROOM LIGHTS KITCHEN LIGHTS HALLWAY LIGHTS WASHING MACHINE NORTH WALL PLUGS NORTH WALL PLUGS REFRIGERATORDINING ROOM PLUGS HALLWAY PLUGS OFFICE PLUGS GFCI STOVE PLUGS BEDROOM PLUGS GUEST ROOM PLUGS 200A BACKUP  GATEWAY (N) TRM  BREAKER (E) PV  BREAKER6020(N) ESS+PV  BREAKER 15F1 F1 HISTORIC-526 S Ross St4/17/2025 PAGE REV: F1 3/27/2025 RUBEN VELASCO 526 S ROSS ST, SANTA ANA, CA,  92701 PROJECT NUMBER:   109R-526VEL1 SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. 7143818044 APN: 010-134-15 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): NEC 706.15(C), CEC 706.15(C) 120/240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC  2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE  REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING  EFFECTIVE WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR  WIRING METHOD AND SHALL NOT BE HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE  ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT  SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2)CAUTION  526 S ROSS ST, SANTA ANA, CA, 92701 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT AC DISCONNECT (EXT) ESS - PCS CONTROLLED (E) PV EQUIPMENT  RAPID SHUTDOWN DISCONNECT LOCATION  (EXISTING SYSTEM AC DISCONNECT) EXPANSION PACK SERVICE ENTRANCE AND GATEWAY  FEEDER BREAKER DISCONNECT BACKUP GATEWAY(EXT) BACKUP LOADS PANEL (EXT) PV SYSTEM(S) ARE EQUIPPED WITH  RAPID SHUTDOWN DEVICE(S) RAPID SHUTDOWN SWITCH SUB PANEL F1 HISTORIC-526 S Ross St4/17/2025