Loading...
HomeMy WebLinkAbout10196145 - PermitCity of Santa Ana Permit Counter (714) 647-5800 20 Civic Center Plaza (N,4-19), Santa Ana lnspection Requests: (714) 667-2738 lnspector Section: (714\ 647-5853 Building w Permit #: {O{96{45 Pin #: 19154 Project Address: 2315 N Riverside Dr Assessor's Parcel. 002-131-30 Lot: 45 Unit:Bldg: Address Range:Suite Range: Zoning: RlBlock NA Tracl.425 Historic Yes Building Use: Job Type: Nature of Work: Existing Bldg. & Use Proposed Use: Single Family Dwelling Solar Solar SFD w/att garage R-3, U VB cBc 2016 x-0602320163J 1 st FL Area 2nd FL Area Other Areas Garage Area Totat Occupancy: Constr Type: Code: Flood Zone: # of Stories: Description of Work: lnstall solar panels Planning Conditions: Owner: Address Contractor: Pure Solar Address: 4047 Grant Street Corona, CA 92879 Phone: (951) 258-1030 State Lic #: 1005423 Lic Type: C-10 Bus. Lic #r 352854 Workers' Compensation lnsurance Carrier: State Fund Policy #: 9146997 Expires: 1111912018 Loyd W Martin Engineering + I Loyd W MartinThomas Proprofsky 23'15 N Riverside Dr Santa Ana, CA 92706 (714) 309-90s7 Engineer Address 2510 W 237th St, Suite 206 Torrance, CA 90505 (310) 464-1804 csa724 P hone Tcnant t P hone: License # Phone: License # Architect / Desiqner: Address: RuiIdin, 01 l16ill. Blde sti 011 16rlr.l I(:t. (:t!e, Planning Approval By: Plan Checked By; Permit lssued By: NPDES lnsp. Req'dl PWA lnsp Req'd: Planning lnsp. Req'd: Landscaping lnsp. Req'd Zuniga, Alliss Date: Date Date: 05/31/20'18 Subject to Field: M Misc. Receipt L4isc. Receipt l\4isc. Receipt 07776002 57607 Pe(mil Fee 07776002 57672 gldg Stds. Revolving 07716002 57600 Genercl Plan Update No No No No Fire lnsp. Req'd: Police lnsp. Req'd No No Account#Total Flood Zone Cert. Req'di No Ol1i6002 5160i Every permit issued shall become invalid unless the wo* on lhe site authoized by such permit is commenced within 180 days aftet its issuance,ot if the wok aulhoized on the site by such permit is suspended ot abandoned for a poriod of 180 days aftet the time the work is commenced $4s0.00 $1 00 $451.00 $0 00 $45't.00 lnspector MtD# 2018-142719 01 1 '16002 51612 Fee Total Paid to Date: Balance Due: ! I Patio: T.l.Area: Yards Req'd Valuation: $14,000.00 $450.00 $1 00 $0.00 DING. INSPECTOR RECORD SITE.WORK DATE lD/stG. -hirEttTS ISet Backs Forms/Steel/Holdowns Erection Pads UFER Ground SLAB Floor Subf loor/Vent/lnsulation Roof Sheathinq Shear Wall Framing lnsu lation/Enerqy Drywall Ext./lnt. Lath Brown Coat lVlasonry Pool Fence T-Bar Handicap Req Deputy Final Report Engineer Final Report Flood Zone Cenif ,,^fdt4tr 4$hciirlg/.7-7-x l- lq)t"/{jtI FINAL 7"1t-l'l t.wlil Certilicate of Occupancy v t\7 Notes, Remarks, Etc. OWNER BUILDER DELCARATION I hcrcl'y aafirnr uDdcr rEnxlry {)i r^-^rjUry tn:( l on cxcmDr lnnr rlN Conrrrnm l,iccn{ L]ls tnr rhc rallo*ing rrnv,n (Ss7oll5 Buli'rcss r Pnncssn Codc): Any Cny or Cor y which rstrnc\ p.nnir lo .otr{ru.i, rlicr, i'nFrvc. dcnnnish or rcpatr rny nfl.trtrc. pr ro ih issuancc. iho rcluncs thc ilpli..nr lor nkh Frnn Io filc.1i3trcd slolcmctrr rhrlhco! shc n liccnscd pusurtrr b rhc prcvi\i,nr of rhc Conkr.rtr s Li.c.{d I-aw tchrprcr 9, Co mcking wirh S.crdn 7fin or Diri\ion :l ol rhc Bu\irc* ,nd Prolcssions C.d.) orrld hcorshc iscxcmp( rhcrc(onrnnd rhc brsir ktrrh. illcScd cxcmrrion. Anyvnn bnolSeclionT0lll 5bynny applicanrinral.nnilsuhjechrlrc.prlicanl(,arivilpcnilryolnolnnrclhxnfivchnndrc do!lrr\($t(x)) -1. !s owner oI lhc lmrcny. or nry cmplores wili uscs is rhct vrc conrpcnelion. rill do rhc sorl and rtE {turm n nor imc cd orollcrcd fu elc tSLr 7{X1, Au\ifts\ nd Pbfc*in\ Codc: Thc G,ntr.kr'\ Lhcnsc bw dds not +r,ly h m oqncr ol rh. pmncny wh) hdilds or inlmv$ rhcNn, and wk' dds suh *odt htr.scli.r hcr\cllor rhough hh or h.r osn cothr.cs, 8)vidcd rhrr \x.h i'npmrc'Enrs m mr ifcn]dt d ollcRal fd slc. !( lk)mrcr. rhc hurlding or impmtuEnr is stl sirhin .m )rr ofcomphrion. rhc O$nc! Blil.icr willhlve rtE hurd.n nfpovin-q lhlr h.or\hcdil to buikr or in\,oft rlf la,tdy nr rh. rurlrr{ ol l. as o*ncrolrhc nmFdy. rmcrclurivclycontrcriig sirh liccn{d cotua6n b.onnrud rtr la,jccr (SLr. 7(x,r. Bu\inc$ rtrd RoL$i,nCod.:ThcContri.roi\LiccnscL!$docstrotrt,rlyl,)!no*ncr.lp'opc,whobuildsornnpnrvcslhrcotr. rid {ho conk cr\ lor rurh !n,}irB sirh , Conhcn*(, li..d\cd Nr$a io rhc Cutrtr.crols l-iccnr tiw) lu,ddnrt, un,lcrS.cri{tri .B &PC ln'rhnrcr([ l)!le O*n.r ]!.QA[[BS:raUr[Nl.lIl!.)N UI'g.JAAL9I I lNnh! rfinn uidcr pci3lrt ol trlury.rtr.l rhc lnlk)wi'rs dc.lnrrri, !l Ihrv.aidwillnrn anrccniturlcolQr*nltusclllnsurcfosorkcm.oDrtcnsilion.as pn,virtcd fu l,rSLrti.n:l7tx).fihc trhor C.dc, for rh. pdr.ntuncc ofrh. {ork for shi.h rhc Jxnni it nucd. ,l lurcrnd willn[intlin *orkc .onlrn\rri{nr i'xtrrm.- J\ rcqun d byS&li( :]Tlnofrhc L{t!tr(od..lorrhc t^-rfonlrNc.l rhe shrk li)rshichrhn Frn,ir is i\\hl My*orkc comFn\di,,n i'rsurdncc.,ni$ Ilolicy Nnlhir nc: _l.cnilyrh r h rhc !crln.n,n.cotrhc *ork fitr ehi.hrhn pciinir n is\ucd.l\hrllforcmrloy rtry trNon i.Mynrlnncr $ r\ro b.conr sxhF-r ro rhc qor kcr{ conlJ*r\r r i lrws ol Cllili,nir Md lgrec rhrr if I sturuld h.cotrr \dhj!--r h rhc workcrs compcrr0rion nroli\ions olS.crion 3700ot(hc lf,txr Codc.l shrll, Ldhwirh.orpl, wlh rh.* B)visiois WARNING [nilur. t, {rnrc aork$J co.r,f,r\nrion..vcn8c i\ unh$lnl. r \h!ll \rhic.r d rtrlPkitrr b di riMl Ftrnlric( r.d c'vil li..\ ur n, onc hd rcd rhou\itrd Sr.!i.n 1076 olihc l-rhtrCodc. nnrr.n trin, x h!c\ r\ nnvLJcd tnr I s 3I IK at)I.( L\Rltl()\ I hcEby,fatrfl undcr pcnalt]olrcrjury th.t I o liccKn undcr pr.vhion orChrpr.t 9 (.onnmncir8 wlh Sati]n 70(xr) otDilhion.l ol rhr Bu$nc$ Nnd Prorcssons codc. nnd my rrccnr rs rn full forcc m,: cnali D IDO Lor4z\ \rK MdVT^Atud- C!}NEIIIISIONIEBDINC.&EINCI I hc(by ir undfiFtrrllyol|xjurythallhcrcnrcon(ruclionhdineascmyforrhcpcrrormn.corrhcworliorwhichlhisPctnrilis issucd (Ss 1097. Cit. C.) L€ndcrs Nam: - AIllllAltDEcL/$AIIllN I lItb, dr6n und.r FnaX, or !.!ury om of thc {dl{rw,ng d{laral iom: Dc!tunii.i P.mir\ A\hcdo\ Norincriio. F.dcirl Rcgnl.rio.s (Titlc.10. Pan6) _Rcquncd lf, ncr ot Norit.drirl I ccniiyrtu rlE lcdelrLrcgulrrion\ rc8rding r\h.{os rcnn,vrlrrc m( lpIl'crhlc t) rhn |,oj..r _l.cnilyrhdIhrvcrclll]rhi\xfrfhcrio dd {rrcrhrrrhcrhJvc nnn idr ir corecr lilrccroconrlly*irhrllCitylndCounry on!inxnc.s xnd sri. l)s\ rcltng n)Drcsctrr0tivcs olrhi\ Ciiy rnd Cou y b cnrcr up.n rtr rhivc nrnri(nrcJ f0r^-dy rbr in Appli({nl or E.nl SiEnoluE tr! con!nr.1(i. I h.rub) +bt ltx ) L'.'l \ ^.lJn.. I I Planning & Bu ilding Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M!19) Santa Ana, CA 92702 (714) 647-s800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST sol-01 cBC 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Project Address:2315 N. Riverside Ave. Santa Ana 92706 Contractor Company Name: Pure Solar ContractorLicenseNumber: 1006423 4 5 YES NO1 gfI 2 Q, tr 3 Eltr gD gtr 9s 10 Eltr Eltrgtr Eltr Are the following applicable to the proposed project? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Wll the PV system weigh maxjmum 4 pounds per square feet or less? Wlll the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the underside of modules and the surface of the roof? Will the PV system be installed without using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages ofthe plans stamped and signed by a California licensed professional engineer? (including project speciflc site plan, PV layout, anchorage spacing, anchorage details and manufacturels PV support information.) 6 7 8 o I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: David Valadez Signature PhoneNumber: 951'426-4602 Date: 5130118 Email Address: ash ley @ pu resolarpros. com **SNIA NA,'ffi .l lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11" x17" size. lf answerinq NO to anv of the ouestions. olan check shall be reouired. *-SANTA NA PL$][tG &ttjlilrc lfi]Icl Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.or9 RESIDENTIAL PHOTOVOLTAIC CHECKLIST Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certiflcation section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11" x 17" size. lf answerinq NO to anv of the questions, plan check shall be required. Project Address:2315 N. Riverside Ave. Santa Ana 9270 6 Contractor Company Name: Pure Solar ContractorLicenseNumber: 1006423 YES NO Eltr Eltr EID gtrgtr Eltr 1 2 o 7 4 Are the following applicable to the proposed project? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the underside of modules and the surface of the roof? Will the PV system be installed without using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Wll the minimum 5/16" lag screws be installed with a minimum of 2-112 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer's PV support information.) I Eltr gtr Uu 10 gtr Email Address: ash ley @ pu resolarpros.com sol-01 cBc 2013 o I certify under penalty of periury under the laws of the State of California that the above is true: Print Name: David Valadez Signature: :+zt7-- Phone Number: 951-426-4602 Date: 5/30/18