HomeMy WebLinkAbout20165793 - PermitCity of Santa Ana
Permit Counter: (7 14) 647-5800
20 Civic Center Plaza (M-19), Santa Ana, C492702 Electrical
lnspection Requests: (714) 667-2738 lnspector Section: (7'14) 647-5853
Proiect Address: 1030 W Sherwood Ln Unil:
Block: NA
Bldg:
Tract: 1939
Address Range:
Historic: No
Suite Range:
Zoning: Rl
E
Assessor'sParcel: 002-242-02 Lot: 38
Owner:
Address
Tri Pham
1030 W Sherwood Lane
Santa Ana, CA 92706
(7',t413',12-8824
Fee Type
011 16002 5'1600 General Plan Update
Amount
2',t .25
Qry
0.00
Fee
$0.00
Phone
Tenant Name:
South West Sun Solar, lnc.
'13752 Harbor Blvd
Garden Grove, CA 92843
(714) 582-3909Phone
State Lic #: 1004667
Lic Type: C-'10
Bus. Lic #r 350754
Workers' Compensation lnsurance:
carrier: COMMERCE & INDUSTRY INSURANCE COMPANY
Policy #: 033571266
Expires: 06/01/2018
Building Use:
Job Type:
Nature of Work
Single Family Dwelling
Solar
Solar
R-3, U
VB
cEc 2016
lvlisc. Receipt:
Misc. Receipt:
Misc. Receipt:
Total
Plan Checked By:
Permit lssued By:
Subject to Field:
Building Permit #:
msden, Julie
10196348 $0.00
$0.00
$0.00
lnspector MID#: 2018-143187
Fee Total:
Paid to Date:
Balance Due:
Permit #: 20{65793
Pin #: 246,89
Contractor:
Address:
Occupancy:
Constr Type:
Code:Notes: lnstall(15) roof mounted solar panels. FEES PD ON
'10196348
Planning Conditions:
Planning Approval By:Date:
Date:
Date:
Every permil issued shall becone invalid unless the work on the slle
authorized by such pemit is commenced within180 days after its
issuance, ot if the work authoized on the sile by such pemit is suspended
or abandoned fot a period o1180 days aftet lhe time the wotk is
commenced.
ost07l201a
Account#
ELECTRICAL-INSPECTOR RECORD
APPROVALS DATE ID/SIG.COMMENTS OWNElr BUIt,DER DELCARATI('N
I hcrcby rfllnD und$ Nnally of |].rjury lhat I on .xcmfl rft'm
'hc
Conkn.ror' Liccnr rjB for thc lollowins reN,n (56 70:11.5
Busircss .nd Profcsio Codc): Any Cily or Counry which r{uncs . p.nnll ro clnllrucl. altcr, improvc. d.mlhh or rcF'n any
sto.rurc, prirto irr iss!m.. akorcquies rhcnpplicanr nn such Frmir k' filc! \igtul sdrdn.' ihnl hcor sh. is liccnEd !u.$!nt
ro Ihc pmvhions of lhc ConlGtolx l-iccnscd Iiw (Chrptcr 9. ComNrcir8 wiri Sccrion 7(x)0 oa Divntun ] olrhr Busincs\ rnd,
PDfe.\ionsCodc)orrhlr hc or shc n cienpr rhcrefromlrdric hasn for rhc alkscd crcmrrion Anyriolarionors(lionr0ll5brrny
amlicxnr for a l]cmir s!br.{k rhr +llicDnr t, a .ivil l,.Mlry of nol mr. rhu fivc hxndrcil dollrs ($50O)
-1.
as osrc! ol rhc pmreny. or my cmployccs $ilh qa8cs as lhct snc conrpcn\slion- will do lhc sor{ a.d rh. strtm N nor
i,trcndcd or orcrcd fir uk 1S.r 7044. Bu\i'res hnd lk,lcs\ions Codc: Thc G)nh.ror's Lkcnk llw docs nol rr/y to !n o{ncr ol
Ihc tmpcny wtk)t ilds or iml,mls rtENn. and who d6 sEh m* hnnscllor hcnclfor rhmuBh his or h.r owncmplorcc\,
pnridcd rh such impovcrnk m r inrcd.i o, oftcr.n nr st li h'w(r rtE builling or irqrorrnr i\ skl wilhin utu ttr
of conroLlhn. lhc Owmr Builds *ill haE rhc l,urdcn ol proviry lhd lt or shc dit nor buikl o! ri\rmvc lhc lmpcny tu rhc purF){ .l
L is ownd orrhc ptup.dy. ancr.lusivclycotrtr.rin8 wirh li..n\cd conr..ror lo consrucl lhe I'rojccl (Sr.'. 7Or4. Bd\incs
and PFI$si,n Codc: The Conlr.ctols Liccnsc Law docs.ol upplyro M.*nc, ol propc.ry rh(, btilds or innrovcs rhc.con.
rnd who c.nrft.rs for !u.h l)ft,Fi* wirh a Contucro(s) liccn\ed ru*usnr rotheContu lor's Liccns tjq)
-l
ifl cxcmfl undcr Secl
D.l.: okm.
W('RKFRS ('oMPEiSATI(N
DSsl,a.EArp!
I hcrct'yorlnmundcrn nlltyolpqjurloncoirnctollowin8dcclarori(nN:
-lhrvcmdwillmrinr.in!CcrrificoreofConscnrtoSclf.lnsurcforwortcr'c.mpcnslrn,n,!sprolidddrubys*lionlTmorrhrtltxtr Codc, for rhc p.rfornErc. olrhc wor* for whdh rhc pdlnil i$ hsu.d.
Ll harc and *ill nrirrnir {o.kcR conDcnsrlion insurancc. as rcquncd 6yScclior]700 o{rhc l-3bor Codc, rur rh psao.nBn.c oi
lic work ior which rhisr.rmilis hsucd. My trorkcrs. om|xnsrron insurumcca cr aDd polny nu'nbcr rc:At/;
6 t?
-l
ccniryrhit in th. pcrroirun.c oflnc work lhr which rhk ncflnir h hsucd. I shallnor cnpn,y lny F$oo i. any m,nncr
$ k, bcom subjccr ro thc work.F Lx,iprnsdi,i laes orCrli{omia Md iCN rhd irl should tNom slbic.l tolhc
workcc..nlrjnunrtdvhk,n\urSccrionlT0OolrhchlrrCdio,lshnll,fonhsilhcomlilywilhlhosprovhions
WARNIN(i: Fnihr. ro {curc q.rkcr' omPrtrsdiotr .ov.rn8. is urhwful. 0nd (hrll sublcd or crqrlo}r! ro Eirninaili.nrkic\ md
.ivil rinc\ un ro otu hr Jnl rhou\rtrd dolhr\ (\l(I).rXXr). i'l cost ofcomf.nsllion. daroscs 6 tn,vidcd ttt ric
- S&rion .1076 or rh. Ltsr Gxl.
&"., 5- 7-,f
inlcrc{ and ormilry\ tccc
--
ArptloDt.
DECI.ASAIION
I hcEby afirm udcr I'cMlly of pcrjury lhal , !n licenscd u(lcr pmvisioi ofchsprd9 (@nmn ing eirh Sccrion 7m0, ofDivision l
of th. BuBi6.ss and Ptufe$ions Codc.
'd
my lic.ns is in rull rn r nnd crcct.
C- (J lao\o b )
9""
,('"( - 14 f,, c*r^"*,
c()Ns'tllti('[oN I ll:tDtN(i acla\(]l
I hcrchy arrn undc, Fmhy ol p.rjury lhar lhec is a .onsid.lbn lcndin8 lscrcy fo! rh. Morurc ot rh. eork for whih thn pcmir ir
hsu.n (56. J097. Civ. C.).
AIPIIIANI.DEqLAEAIION
I hceby ,tim uidei pendry or perju,y om or lhc rollosing deld,! ions
Dcmlirion Pcrmirs-Ashcsros Norifi clrion Fcdcral Rc8!lorions (Tirlc 40, Pln6)
-Req!ncd
Lcllerof Noriarclrion
I ..niryrhar rhc r.dcr.lrcSuldioN rcSrdire a$.sos rcm,vrlrc mr aptli.ahlc to rhis lrojc.r
-l
ccniryrhd I nrvcrc.drhh !,,I1licirion md n arc rlFr rhc rtnvc nrlnrMri.n G cotrccr I trsr&!o.onfty*iihsllciry.fld Counry
odimnccs flnd Sratc tj*s Ehrins ro buildi.E con(ructiotr. oM hcrch, (urhorirc repE\cnlnrnc\ orrhis Ciry Md Countyto cnlcr u,'nn rrt
L$.rc nrnrtr,Nd rm|cny n flntFri' rrI[rFG.\
Jtppri.rntorAaenrsr*MroF -k
\ Pemirerume,prin.: L/*'.L l/'l
I)=lS-
Site-Work
Underground
Pole Bases
Light Standards
Spas, Pool, Fountains
Signs (monument)
Life Safety /Low Voltage
Fire Alarm / Dampers
Communications Cable
Buildinq
Under Slab / Floor
Bondinq / Groundinq / UFER
Transformers
Torqueino
Sub-Panels
Air Conditioners
Roof Top Equipment
Factory Wired Unit
Walls (Conduit)
Walls (Rough)
Ceilings (Hard & Soffit Rouoh
Ceilinqs (T-Bar Rouoh)
[,4eter Release
Rouqh
Service Meter
FINAL Ut/lq Sir 1\rFfi6
Notes, Remarks, Etc.
r,n,r,", 0l& t'-)-, z r. r,pn".,
I
--I
------f----
I
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
soL-01 cBc 2013
Solar Photovoltaic (PV) Checklist tor Detached STNGLE FAMTLY RESIDENCES Onty
lnstructions: The licensed contractor of record shall complete all sections, answer lhe ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum'11" x 17" size. lf answerino NOt o anv of the questions. Dlan check shall be required.
Proiect Address:1O3O S. SHERWOOD LANE, SANTA ANA, CA 92706
Contractor Company Name:SOUTHWEST SUN SOLAR, INC
contractor License Number: 1004667
2
YES NOatr
Ettr
Etr
Etr
Etr
Etr
atr
Etr
Ettr
Etr
Are the following applicable to the proposed project?
Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan?
Will the PV system be installed on a roof having only one rooling layer with no
overlays?
Will the PV array be flush mounted to the exisling roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
Will the PV system weigh maximum 4 pounds per square feet or less?
Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be installed with a space of 2, minimum to 10" maximum between
the underside of modules and the surface of the roof?
Will the PV system be installed without using any ballast system or counter-weight
system?
Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on lhe plans?
Are ALL tha structural pages of the plans WET stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
3
6
7
I
I
10.
anchorage spacing, anchorage details and manufacturefs PV supp ort information
I certify under penalty of periury under the laws of the Slate of California above is true:
print Name: TRANG CONG PHAM Signature
phone Number: 714 582 3909 Dale:c
Emait Address: PERIV lT@SOUTHWESTSUNSOLAR.COM
Revi 8/'1 7/201 5
at
,--SANTA
NA-"ffiT
Planning & Building Agency
Building Satety Division
20 Civic Cenler Plaza
P.O. Box '1988 (M-19)
Santa Ana, CA 92702
(714) 647-s8oo
www.santa.ana.org
4.
5.
-:al---PERt\ffrwPE' El-iit
,.-lbs133
, R$ o \'
irr- \R _-2n\\j
--*
JtetlL JL t
EXPEDITED PERMIT PROCESS FOR PV SYSTEMS
MICRO-INVERTER
The Solar America Board for Codes and Standards (Solar ABCS) Expedited Permit Pro-
cess provides a means to differentiate systems that can be permirted quickly and easily
due ro their similarily with the majoriry of small-scale PV systems. Those systems with
unique characteristics may be handled with small addirions to this Expedited Permit
Process or may require much more information, depending on the uniqueness of the
insaallation.
The following pages contain forms for the Micro-lnverter to use with the Expedited Per-
mit Process. The Standard String. AC Module. and Supply-Side Connection lorms
are also available as inrerac[ive PDF files ar www.solarabcs.org/permitting. In jurisdic-
tions that have adopted the Expedired Permit Process for PV Systems, rhese forms can
be filled out eleccronically and submirted in either prinred form and via email. An elec-
tronic Format is used so that the supplied information is standardized and legible for rhe
local jurisdiction.
t
occ. GBOi
CODE EDIIK)Ii
t
I
I
EXPEDITID PERMIT PROCESS FOR PV SYSTEMS - MICRO,INVERTER
EXPEDITED PER]VIIT PROCESS FOR SMALL.SCALE PV SYSTEMS
NA ICRo-I NVERTE R
The information in this guideline is inrended ro help local jurisdictions and contractors idenrify when PV system installations
are simple, needing only a basic review and when an installation is more complex. It is likely that 50%-75 % of all residential
systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolulion steps have been
suggested to provide as a path to permit approval.
Required Information Jor Permit:
l. Sire plan showing location of major componenB on the properry. This drawing need not be exactly to scale, but it
should represent relative locarion of components at site (see supplied example site plan). PV arrays on dwellings
with a 3'perimeter space at ridge and sides may nor need separare fire service review.
2. Electrical diagram showing PV array conhguration, wiring system, overcurrent protection, inverter, disconnects,
required signs, and ac connecrion to building (see supplied standard electrical diagram).
3. Specificarion sheets and insrallarion manuals (if available) for all manufacrured components including. but not
limired ro. PV modules, inverter(s), combiner box, disconnects, and mounring sysrem.
Step 1 : Structural Review o[ PV Array Mounting System
Is the aray to be mounted on a dehned, permitted roof structure? @Yes lNo
U No due to non-compLiant roo.f or a ground mount. submit completed worhsheet lor the structure wKSl.
Roof Infonnation:
Yes1 Is the roohng rype Iighrweight (Yes = composition, Iightweight masonry, metal, etc ..)
l. Provide method and type of weatherproofing roof penetrarions (eg nashing. caulk)F las hing
M o untin g Sy st em InJonnation :
L. Is rhe mounting sLructure an
benearh the module Frames?
cIl neered producr designed ro mounr PV modules with no more rhan an l8' gap
Yes ! no
IJ No, provide details o.f structural attachment certifed by a design prolessionaL
2. For manufactured mounting sysrems, nll our information on the mounring system below
producr Name nn6 114o4"1y Solar Mounta Mounrino svsrem Manutacrurer SWH
b. Total weighr of PV Modules and Rails 736 Ibs
c. Total Number of Attachment Poin r. 32
d. Weight per Aftachment Poinr (b + c)23 bs (if greater than 45 lbs, see WKS l)
e
242.39 tur
2.61 Ibs/fu'?
IJ distributed weight oJ the Pv system is grcatet than 5 lbs/ft'., see wKSl .
Step 2: Electrical Review o[ PV System (Calculations lor Electrical Diagram)
ln order for a Pv system to be considered for an expedited permit process, the fotlowing must apply:
l. PV modules, utiliry-interactive inverters, and combiner boxes are identined for use in PV systems.
2. The PV array is composed of 4 series slrings or less per inverter
3. The total invener capacity has a continuous ac power output I J,440 Watts or less
4. The ac interconnection point is on the load side of service disconnecting means (690.64(8)).
5. One ot the standard electrical diagrams(El.1,E1.1a,E1.1b,orEl.1c)canbeusedtoaccuratelyrepresentrhePV
sysrem. lnteractive PDF diagrams are available ar www.solarabcs.org/permitting.
Fill out the standard electrtcal diagram completely. A guide to the electrical diagram is provided to help the applicant
understand each blank to ftl tn. U the elec1'ical system is more complex than the standard electrical dtagram can elJectively
communicatq provide an alternative diagram with appropriate detail.
2 ExpEDlrED PERMTT PRocEss FoR PV sysrEMs - MrcRo-lNVErrrER
Maximum Spacing Between Attachment Points on a Rail 72 inches (see product manual tor
maximum spacing allowed based on maximum design wind speed)
f. Total Surface Area of PV Modules (square feeo
g. Distribured Weight of PV Module on Roof (b + 0
IJ No, submit completed worksheetJor roo.f structure w(S, (No = heary masonry, slqte, etc...).
2. Does rhe rool have a single roof coveringr Eyes f]no
If No, submit completed worksheetJor rool structure WKSI .
Property Layout
SHERWOOD LN
I
DRIVEWAY
1
Uz
=rdUcotI
!vo!m7
1
trz
m
+F*l
I
o
I I
PROPERTY LINE
LEGEND
lMPlMain Electrical Service Panel
fAclAC Disconnect
IINMlnverter
SUESub Panel/Electrical Load Center
fCEfl Combi ner Box/Panelboa rd
lSfClPanelboard For Solar Only
fElExisting Solar Equipment
PATIO
PV-A2
Property Layout
Scale: 3/32" = 1'
Rev:5/3/1 I
Drawn:5/3/20 1 I
I
G
oo
oo'd
0-
zEJN
= X Q?g E yod s i<
-ouZE -l r<F J o<
6Zo{
o olrldI_Nl. _6 0 0 IoF:d d^ lE
B#esftqB,rlg
atrc*68 llo
;EsEs!F:1F
t\
/,
NA ICRO-I NVERTER ELECTRICAL DIRC RAM
M
8
7
MOD MOD MOD
L 6
5
3 4
AC D|SCO
2 Mj-Box
MAIN SERVICE PANEL
MAIN )
INVERTER
OCPD
a
MOD MOD MOD
aI
a
B
E8AC COMStN
PANEL
5
L
4
3
CONDUIT AND CONDUCTOR SCHEDULE
NUi/BER OF CONDUITTAGDESCRIPTION OR CONDUCTOR TYPE COND.CONDUIT
GAUGE CONDUCTORS TYPE
1 USE-2 fl or PV WIRE E!MFG t!4FG Cable N/A
One-Line Standard Electrical Diagram
for Micro-lnverter PV Systems2GEC E EGC tr X ALL THAT APPLY N/A
3 EXTERIOR CABLE LISTED W/ INV MFG I\,,1FG Cable N/A
4 THWN-2 E or XHHW-2 E or RHW-2 E
GEC B EGC tr X ALL THAT APPLY SAME SAME
SIZE
N/A
N/A
N/A T SUN SOLAR. INC
HARBOR BLVD
GROVE, CA 92843
Conlractor Name.
Address and Phonel
Site Name: rRr PHAM
site Address: 1030 SHERWOOD, SANTA ANA, CA 92706
System trQ $i2s; 4.80
DWG NO REVNO DC GEC IF 690.35 SYSTEM
Drawn By
5 THWN-2 E or XHHW-2 E or RHW-2 E
SAMEGEC E] EGC E] X ALL THAT APPLY Chected By:SAME scAtt NTS Date:SBEII
o EQUIPMENT SCHEDULE
TAG DESCRIPTION PART NUMBER NOTES
1 PV DC or AC MODULE TRINA SOLAR -TSM-300DD05A.05(ll)
2 DC/AC INVERTER (IVICRO)Enphase lQ6-60-X-US(240V)
3 J-BOX (IF USED)Nema 3R
4 PV ARRAY
5 AC COMB. PANEL (IF USED)
6 GEN IVETER (IF USED)
7 AC DISCONNECT (IF USED)Square D 30amp DU221 RB / 60amp DU222RB NEMA 3R
8 SERVICE PANEL
UTILITY
SERVICE
qEE GIJIDE APPENDIX D FOB
a a a aa ARRAY GROUNDING
N/ICRO.INVERTERS
IN BRANCH-
CIRCUIT
a a a aa BUILDING
GROUNDING
ELECTRODE
T,4ICRO-INVERTERS
IN BRANCH.
CIRCUIT
a
I
I
a
EQB-]JNUS LD.MO_D U I- E S
P!T_N/A" in ELANKASOVE
:
UJF6
lr'\
n-
&oL
a
U
c-
F
:
aa-
og.lioa
o-x
trJ
rl-
-------!
aI
a
I
Notes for One-Line Standard Electrical
Diagram for Single-Phase PV Systems
Site Name: TRI PHAM
Site Address: 1o3o sHERWooo SANTAANA, cA 92706
System AC Size: 4.80
NT5
PV MODULE RATINGS @ sTC (Guide Sect on 5)
MODULE MAKE TRINA SOLAR
MODULE MODEL TSrV-300DD05A.os(il)
I\,4AX PoWER-POINT CURRENT (lvp)9.1 I
Jt.o
OPEN-CIRCUIT VOLTAGE (VO')
SHORT.CIRCUIT CURRENT (IS')
39.9
9.64
[,lAX SERIES FUSE (OCPD)20
MAXIMUM POWER (P',d)300
[,4AX VOLTAGE (TYP 6OOVDC)600
VoC TEMP CoEFF (mvfctr or %fctr)1.12
IF COEFF SUPPLIED, CIRCLE UNITS
NOTES FOR ALL DRAW NGS
OCPD = OVERCURRENT PROTECTION DEVICE
NATtoNAL ELEcTRIcAL coDE" REFERENcES
sHowN AS rNEC XXX.XX)
IUVIBIIB BAIINGILGu id! 5cc!1al4)
INVERTER MAKE Enphase
INVERTER MODEL
I\,{AX OC VOLT RATING
r\rAX POWER @ 40oC
NON4INAI AC VOL IAGF
244
240
I\,4AX AC CURRENT
MAX OCPD RAT NG
0.96
20
r06-60-s-us (240v)
48
S GN FOR DC D SCONNECT
No sign necessary since 690.51
marking on PV module covers
needed information
SIGN FOR NVFRTFR O'PD AND A'
DrscoNNEcT (rF usED)
SOLAR PV SYSTEM
AC POINT OF CONNECTION
AC OUTPUI CURRENI 15.36
NO[,4INAL AC VOLTAG E 240V
THIS PANEL FED BY MULTIPLE
SOURCES (UTILITY AND SOLAR)
NoTES FoR ARRAY!IBCU[]&!8!NG iGuide section 6 and 8 and Aooendix EJ
1,) LOWEST EXPECT AMBIENT TEI\,lPERATURE BASED ON ASHRAE MINII\,4UM MEAN
EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOSI SIMILAR IO
INSTALLATION LOCATION. LOWEST EXPECIED AI\,'lBlENT TEI\4P 10 oC
2,) HIGHEST CONTINUOUS AIIBIENT TEI\,IPERATURE BASED ON ASHRAE HIGNEST
I!,4ONTH 2% DRY BULB TEI\4PERATURE FOR ASHRAE LOCATION ]VOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINI]OUS TEI/PERATURE 65 "C
2.r 2009 ASHRAE F-NDAI\,IEN IAL S 2olo DESIGN TEMPERATURES DO NOT EXCEED
4IOc IN -HE UNTTED STATES IPALM SPqINGS, CA IS 4a .OC) FOR LESS THAN 9
CURRENT.CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT
LEAST 0,5'ABOVE ROOF AND USING IHE OUTDOOR DESIGN TEMPERATURE OF
47"C OR LESS (ALL OF UNITED STATES)
a, 12 AwG, 90'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR I\,4ODLLES
wlTH lsc oF 7.68 AI PS OR LESS WHEN PROTECTED BY A l2-AMP OR SMAL-ER
FUSE,
b) .O AWG, gO.C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR I\,4ODLt FS
Wllrl lsc OF 9.6 AMPS OR LESS WrIEN PRO IFC I l-D BY A 1s-AMP OR SMALLER
FUSE,
NoLESIOB INVEBIEEoACUIIS lG! € :
1) IF UTILITY REOUIRES A VISIALE.BREAK SWITCH, DOES THIS SWITCH MEET THE
REQUIREIVIENT? YES E NOtr N/AE
2) IF GENERATION IVETER REOUIREO, DOES TNIS [,4ETER SOCKET MEET THE
REOUIREMENT? YES E NO tr N/A tr
3)SIZE PHOTOVOLTAIC POWER SOURCE (DC)CONDUCTORS BASED ON I!,1AX
CURRENT ON NEC 690,53 SIGN OR OCPD RATING AT DISCONNECI
4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER
OCPD AMPERE RATING. (See Guide Seclion 9)
5)TOTAL OF INVERTER OUTPUT CIRCUIT OCPD(S), ONE FOR EACH l\,llcRo-
INVERTER CIRCUIT. DOES TOTAL SUPPLY AREAKERS COMPLY WITT] 12OOIO AUSEAR
EXCEPTION lN 690 64(B)(2)(a)? YESE NOtr
NOTES FOR NAICRO-INVERTER ELECTRICAL DIAGRAM
F
a
Uo
t
d
o
io
SOUTHWEST SUN SOLAR INC
13752 HARAOR BLVO
GARDEN GROVE CA 92843
SIGNS-SEE GU]DE SECTION 7