HomeMy WebLinkAbout610 S BroadwayV2 - 101110702 & 20176387 - PlanSHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-1 COVER SHEET PROJECT NARRATIVE: SYSTEM DESCRIPTION: 1. 5.135 KW DC GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM 2. (1) ARRAY ON A SINGLE STORY RESIDENCE WITH A COMPOSITION SHINGLE ROOF. 3. (1) INVERTER LOCATED NORTH WALL. 4. CONNECT SYSTEM TO MSP WITH A NEW 2-POLE PV BREAKER. 5. RUN EMT ON ROOF, UNDER EAVES ON THE EXTERIOR OF THE RESIDENCE. 6. ROOF STRUCTURE: 2" X 4" RAFTERS @ 24" O.C 7. FIRE RATING: CANADIAN TYPE-2 MODULE WITH UNIRAC CLASS-A RACKING SYSTEM EQUIPMENT LIST: (13) CANADIAN SOLAR CS3N-395MS (395W) (13) SOLAREDGE POWER OPTIMIZERS: P400 (1) SOLAREDGE WAVE 3.8KW INVERTER: SE3800H-US-RGM (22) UNIRAC UNIVERSAL AF MID CLAMPS (8) UNIRAC UNIVERSAL AF END CLAMPS (26) UNIRAC FLASHLOCK MOUNT FOOTING (~92FT) UNIRAC SOLARMOUNT STANDARD RAIL (1) 20 AMP 2-POLE PV BREAKER (AT MSP) REFERENCE CODES AND CONSTRUCTION NOTES: THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: 2019 CALIFORNIA ELECTRICAL CODE (CEC), 2019 CALIFORNIA RESIDENTIAL CODE (CRC), 2019 CALIFORNIA BUILDING CODE (CBC), 2019 CALIFORNIA FIRE CODE (CFC), 2019 CALIFORNIA PLUMBING CODE (CPC), 2019 CALIFORNIA MECHANICAL CODE (CMC), MANUFACTURER AND PV INDUSTRY STANDARDS, AND ALL STATE AND JURISDICTION BY-LAWS AND ORDINANCES. PROJECT SHALL BE INSTALLED BY A LICENSED CONTRACTOR. VICINITY MAP: (NOT TO SCALE)FRONT OF RESIDENCE PV SYSTEM SUMMARY : 5.135KW ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM SYYSTEM SIZE (DC) : STC: 13 X 395 = 5135 W DC : PTC: 13 X 372.75 = 4845.75 W DC SYSTEM SIZE (CEC-AC): 13 X 372.75 X 99% = 4797.29 W AC MODULES : 13 X CANADIAN SOLAR CS3N-395MS (395W) INVERTER : 1 X SOLAR EDGE SE3800H-US-[RGM] ROOF : COMPOSITION SHINGLE TILT : 20° PITCH AZIMUTH : 180° SHEET INTEX PV-1 COVER PV-2 SITE PLAN PV-2A OPTIMIZER CHART PV-3 ARRAY LAYOUT PV-3A FIRE NOTES PV-4 STRUCTURAL ELEVATION PV-5 SINGLE LINE DIAGRAM PV-5A ELEVATION PV-6 ELECTRICAL NOTES PV-7 PLACARDS ATTACHMENTS: + MODULE SPEC SHEET + INVERTER SPEC SHEET + RACKING SPEC SHEET + ENGINEERING LETTER # OF ARRAYS PITCH ORIENTATION 1 20°180° JURISDICTION CITY OF SANTA ANA Bldg# 101110702 Elec# 20176387 Issued 06/08/22 610 S Broadway 06/09/22 MSP AC INV JB SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 SITE PLAN SCALE: 1/16" = 1'-0"1 PV-2 SITE PLAN NOTES: · SMOKE / CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED AND IN WORKING CONDITION. · NOTIFY UTILITY COMPANY BEFORE ACTIVATION OF PV SYSTEM. · DO NOT INSTALL INVERTER WHERE IT COULD BE EXPOSED TO DIRECT SUNLIGHT TO AVOID UNWANTED POWER REDUCTION DUE TO AN INCREASE IN THE INTERNAL TEMPERATURE OF THE INVERTER. NORTHNORTH APN #: 6212013049 SPRINKLER SYSTEM: NO TOTAL ROOF AREA: 2179.72 SOLAR ARRAY AREA: 289.96 % AREA COVERAGE: 13.30% (N) AC DISCONNECT SWITCH (E) RESIDENCE (E) MAIN SERVICE PANEL (SOLAR POINT OF CONNECTION) (N) PV ARRAY AR-01 (E) PROPERTY LINE (E) GARAGE 49'-2"(N) SOLAR EDGE SE3800H-US-[RGM] INVERTER W/ INTEGRATED DC DISCONNECT (NORTH WALL)S BROADWAY(E) DRIVEWAY 1204.2.1.1 PATHWAYS TO RIDGE NOT FEWER THAN TWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES FIRE CODE 1204.2.1.2 SETBACKS AT RIDGE FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. ROOF ACCESS POINT 141'-8"49'-2"141'-8" (E) SHED ROOF ACCESS POINT 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-2A OPTIMIZER CHART 610 S Broadway 06/09/22 MSP AC INV JB SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-3 ARRAY LAYOUT 2" X 4" RAFTERS @ 24" O.C MODULE DETAILS SCALE: 1/2" = 1'-0" 2 ROOF PLAN WITH MODULES LAYOUT SCALE: 1/8" = 1'-0" 1 (N) UNIRAC SOLARMOUNT STANDARD RAIL (N) CONDUIT RUN: 3/4" EMT (N) ROOF MOUNTS EVERY 72" O.C MAX (N) JUNCTION BOX (UNDER ARRAY) ADDITIONAL NOTES: · FINAL LOCATION OF ALL CONDUIT AND JUNCTION BOXES TO BE DETERMINED AT TIME OF INSTALLATION. · CONDUIT TO BE PAINTED TO MATCH EXTERIOR OF RESIDENCE WHERE APPLICABLE AND IS TO BE SUPPORTED EVERY 10' MAX. · 30" WIDE X 36" DEEP WORKING SPACE CLEARANCES REQUIRED ABOUT ALL ELECTRICAL EQUIPMENT. · STAGGER PENETRATIONS TO EVENLY DISTRIBUTE LOAD ACROSS ALL TRUSSES UNDER ARRAY. · ALL DIMENSIONS ARE APPROXIMATIONS. · DO NOT INSTALL INVERTER WHERE IT COULD BE EXPOSED TO DIRECT SUNLIGHT TO AVOID UNWANTED POWER REDUCTION DUE TO AN INCREASE IN THE INTERNAL TEMPERATURE OF THE INVERTER. CONSTRUCTION NOTES · ROOF PITCH: 20° · ROOF CLADDING: COMPOSITION SHINGLE · ROOF STRUCTURE: 2" X 4" RAFTERS @ 24" O.C O/C · MOUNTS ARE ON GRID SPACING, OCCURRING AT RAFTERS. · VERIFY RAFTER LOCATIONS IN FIELD. · REFER TO MODULE AND RACKING MFR'S INSTALL MANUALS. · MAX SPAN BETWEEN MOUNTS: 72" O.C. · PLUMBING AND MECHANICAL VENTS SHALL NOT BE COVERED BY SOLAR MODULES. · ALL FASTENERS STAINLESS STEEL U.O.N. (N) PV ARRAY AR-01 (289.96 SQ.FT.) (E) MAIN SERVICE PANEL (SOLAR POINT OF CONNECTION) (N) AC DISCONNECT SWITCH STRING 1 ROOF AREA STATEMENT ROOF MODULES QTY PITCH TRUE ORIENTATION 1 13 20°180° PV-4 1 SPECS: L : 76.4" W : 41.3" D : 1.38" 49.6 LBS CANADIAN SOLAR CS3N-395MS (395W) 76.4" 41.3" 1.38" 20° (N) SOLAR EDGE SE3800H-US-[RGM] INVERTER W/ INTEGRATED DC DISCONNECT (NORTH WALL) 13 MODULES 180° AZIMUTH MODULE ROOF AREA: 851.01 SOLAR ARRAY AREA: 289.96 % AREA COVERAGE: 34.07% NORTH 3' 3' 26'-7" 20'-8" This item has been digitally signed and sealed on May 12, 2022 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-3A FIRE NOTES 1204.1 General Solar photovoltaic systems shall be installed in accordance with sections 1204.2 through 1204.5, and the California Building Code or California Residential Code. The electrical portion of solar PV systems shall be installed in accordance with the California Electrical Code. 1204.2 Access and Pathways Chapter 12 Energy Systemshttps://up.codes/viewer_export/juris_key/california/pub/california_fire_code_2019/ref/12 6/24Roof access, pathways, and spacing requirements shall be provided in accordance with Sections 1204.2.1 through 1204.3.3. Pathways shall be over areas capable of supporting fire fighter accessing the roof. Pathways shall be located in areas with minimal obstructions, such as vent pipes, conduit or mechanical equipment.Exceptions:1. Detached, no habitable group structures including, but not limited to, detached garages serving group R-3 buildings, parking shade structures, carports, solar trellises and similar structures.2. Roof access, pathways and spacing requirements need not be provided where the fire code official has determined that rooftop operations will not be employed. 1204.2.1 Solar Photovoltaic Systems for Group R-3 Buildings Solar photovoltaic systems for Group R-3 buildings shall comply with Sections 1204.2.1.1 through 1204.2.1.3.Exceptions :1.These requirements shall not apply to structures designed and constructed in accordance with the California Residential Code.2. These requirements shall not apply to roofs with slopes of 2 units vertical in 12 units horizontal or less. 1204.2.1.1 Pathways to ridge not fewer than two 36-inch-wide (914 mm) pathways on separate roof planes, from lowest roof edge to ridge, shall be provided on all buildings. Not fewer than one pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, not fewer than one 36-inch-wide (914 mm) pathway from lowest roof edge to ridge shall be provided on the same roof plane as the photovoltaic array, on an adjacent roof plane or straddling the same and adjacent roof planes 1204.2.1.2 Setbacks at ridge for photovoltaic arrays occupying 33 percent or less of the plan view total roof area, a setback of not less than 18 inches (457 mm) wide is required on both sides of a horizontal ridge. For photovoltaic arrays occupying more than 33 percent of the plan view total roof area, a setback of not less than 36 inches (457 mm) wide is required on both sides of a horizontal ridge. 1204.2.1.3 Alternative setbacks at ridge where an automatic sprinkler system is installed within the dwelling in accordance with Section 903313 setbacks at the ridge shall conform within the dwelling in accordance with Section 903.3.1.3, setbacks at the ridge shall conform to one of the following:1For photovoltaic arrays occupying 66 percent or less of the plan view one of the following:1. For photovoltaic arrays occupying 66 percent or less of the plan view total roof area a setback of not less than 18inches (457 mm) wide is required on both sides total roof area, a setback of not less than 18inches (457 mm) wide is required on both sides of a horizontal ridge 2 For photovoltaic arrays occupying more than 66 percent of the plan view a horizontal ridge.3. For photovoltaic arrays occupying more than 66 percent of the plan view total roof area a setback of not less than 36inches (914 mm) wide is required on both sides total roof area, a setback of not less than 36inches (914 mm) wide is required on both sides of a horizontal ridge a horizontal ridge. 120.4.2.2 Emergen1204.2.2 Emergency escape and rescue openings panels and modules installed on Group R-3 buildings shall not be placed on the portion of a roof that is below an emergency escape buildings shall not be placed on the portion of a roof that is below an emergency escape and rescue opening A pathway of not less than 36 inches (914 mm) wide shall be provided and rescue opening. A pathway of not less than 36 inches (914 mm) wide shall be provided to the emergency escape and rescue opening the emergency escape and rescue opening.120.4.2.3 Locations of DC Conductors Conduit 1204.2.3 Locations of DC conductors conduit, wiring systems, and raceways for photovoltaic circuits shall be located as close as possible to the ridge or hip or valley and from the hip or circuits shall be located as close as possible to the ridge or hip or valley and from the hip or valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilate valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilation opportunities conduit runs between sub arrays and to DC combiner boxes shall be installed in opportunities. Conduit runs between sub arrays and to DC combiner boxes shall be installed in a manner that minimizes the total amount of conduit on the roof by taking the shortest path from a manner that minimizes the total amount of conduit on the roof by taking the shortest path from the array to the DC combiner box. The DC combiner boxes shall be located such that conduit the array to the DC combiner box. The DC combiner boxes shall be located such that conduit runs are minimized in the pathways between arrays DC wiring shall be installed in metallic runs are minimized in the pathways between arrays. DC wiring shall be installed in metallic conduit or raceways when located within enclosed spaces in a building Conduit shall run a conduit or raceways when located within enclosed spaces in a building. Conduit shall run along the bottom of load bearing members the bottom of load bearing members. 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-4 STRUCTURAL ELEVATION QUANTITY WEIGHT / UNIT TOTAL WEIGHT MODULE 13 49.6 LBS 644.80 LBS OPTIMIZER 13 1.40 LBS 18.20 LBS FOOTINGS 26 1.25 LBS 32.50 LBS RAILING 92FT 0.75 LBS/FT 69.00 LBS UFO CLAMPS 22 0.10 LBS 2.2 LBS END CLAMPS 8 0.10 LBS 0.80 LBS WEIGHT OF ARRAY 767.50 LBS AREA 851.01 SQFT WEIGHT PER AREA 0.90 LBS/SQFT STRUCTURAL EVALUATION: DEAD LOAD: 0.90 PSF < 4.0 PSF OK 24.9 LBS/PEN < 45 LBS/PEN OK FOOTING SPACING: 72" = 72"" OK LAG BOLT SCHEDULE LOCATION INFIELD 3' SIDE ZONES 3' CORNER ZONES BOLT SIZE 5/16" x 3-1/2" 5/16" x 3-1/2" 5/16" x 3-1/2" MIN EMBED 2-1/2" 2-1/2" 2-1/2" TOP PLATE LOAD BEARING WALL RIDGE BOARD 2" X 4" RAFTERS @ 24" O.C MID CLAMP SOLAR MODULE 5/16" X 3-1/2" LAG BOLT WITH 2-1/2" MIN. EMBEDMENT (2 PER FOOTING) 20° UNIRAC SOLARMOUNT STANDARD RAIL UNIRAC SOLARHOOK FLASH LOCK FOOTING MATERIAL LIST 1 SOLAR EDGE SE3800H-US-[RG M] QTY EQUIPMENT DESCRIPTION 13 CANADIAN SOLAR CS3N-395MS (395W) 1 JUNCTION BOX 600VDC, NEMA 3R, UL LISTED 1 AC DISCONNECT 600VAC, 30A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 20A 26 ATTACHMENTS UNIRAC FLASHLOCK MOUNT FOOTING 92' RAIL UNIRAC RACKING 22 MID CLAMPS UNIRAC UNIVERSAL AF MID CLAMPS 8 END CLAMPS UNIRAC UNIVERSAL AF END CLAMPS 50' CONDUIT 3/4" OR LARGER EMT CONDUIT 1/2" PLYWOOD SHEATHING COMPOSITION SHINGLE ROOF @ 20° PITCH OPEN CIRCUIT VOLTAGE (Voc) : MAX. POWER VOLTAGE (Vmp) : SHORT CIRCUIT CURRENT (Isc) : MAX. POWER CURRENT (Imp) : PTC RATING : 44.3V 37.0V 11.44A 10.68A 372.75W MAX. DC INPUT VOLTAGE : MAX. AC OUTPUT VOLTAGE RANGE : MAX. AC OUTPUT CURRENT : MAX. AC POWER OUPUT : CEC EFFICIENCY : 480V 211-264V 16.0A 3800W 99% This item has been digitally signed and sealed on May 12, 2022 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-5 SINGLE LINE DIAGRAM NOTES: · CONDUTORS ON ROOF MUST BE SUNLIGHT RESISTANT, 90°C RATED AND SUITABLE FOR WET LOCATIONS. · SEE RACKING SPEC SHEETS FOR RACKING EQUIPMENT GROUNDING METHOD. · ALL GROUNDING CONDUCTORS MUST BE PROTECTED FROM DAMAGE IF NOT INSTALLED IN CONDUIT. · ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF. · ALL DEVICES USED FOR BONDING FRAMES OF MODULES OR OTHER EQUIPMENT TO THE GROUNDING SYSTEM MUST BE LISTED AND IDENTIFIED FOR THE PURPOSE. · SOLAREDGE OPTIMIZERS ARE TO BE BONDED TO RACKING BY USING EITHER AN OPTIMIZER ATTACHMENT KIT OR A SOLAREDGE GROUNDING PLATE. (SEE SPEC SHEETS). · ALL CONDUCTORS SHALL BE COPPER. · ALL ROOFTOP RACEWAYS SHALL BE INSTALLED A>=7/8" ABOVE ROOF. · INTEGRATED GROUNDING IN ACCORDANCE WITH THE RACKING MANUFACTURER INSTALLATION INSTRUCTIONS CAN ONLY BE USED FOR BONDING THE MODULES TO THE RACKING WHERE THE SPECIFIC MODULE CATALOG NUMBER HAS BEEN TESTED TO UL2703 STANDARDS BY AN ACCREDITED NRTL. WHERE THE MODULE CATALOG NUMBER IS NOT PART OF THE RACKING SYSTEM APPROVED MODULE LIST, BOND ALL MODULES AND ALL RAILS USING A UL2703 LISTED LAY-IN LUG SUCH AS ILSCO GBL-4DBT. 5.135 kW (DC) SOLAR ARRAY: (13) CANADIAN SOLAR CS3N-395MS (395W) WITH (13) SOLAREDGE POWER OPTIMIZERS: P400 WITH (1) SOLAREDGE WAVE 3.8KW INVERTER: SE3800H-US-RGM (1) STRING OF (13) MODULES UTILITY METER 100AMP 2-POLE MAIN BREAKER (N)20AMP 2-POLE PV BREAKER N G 3/4" EMT OR EQUIVALENT (ON ROOF, UNDER EAVES) (2) #10 AWG THWN-2 CONDUCTORS (1) #8 AWG THWN-2 GROUND CONDUCTORS EXPOSED TO FREE AIR (2) #10 AWG PV-WIRE 600V/RHW-2 (1) #6 AWG BARE COPPER GROUND WIRE IN CONDUIT CAN BE #8 AWG THWN-2 3/4" EMT OR EQUIVALENT (2) #8 AWG THWN-2 CONDUCTORS (1) #8 AWG THWN-2 NEUTRAL (1) #8 AWG THWN-2 GROUND AC DISCONNECT (WITHIN 10' OF MSP) NEMA TYPE 3R UL LISTED JUNCTION BOX AR-01 (13) CANADIAN SOLAR CS3N-395MS (395W) IN (1) STRING OF (13) MODULES AT (20°) PITCH AND (180°) ORIENTATION 120/240 VAC SERVICE EXISTING 100A MAIN SERVICE PANEL W/ 100A MAIN BREAKER ON CENTER FED. INSTALL NEW 20A 2-POLE PV BREAKER AT END OF BUS BAR. AC OUT DC IN NOTE: INTEGRATED DC DISCONNECT IS INSTALLED WITH RAPID SHUTDOWN DEVICE BY MANUFACTURER IN COMPLIANCE WITH NEC 690.12. (13) SOLAREDGE: P400 DC OPTIMIZERS NEW SQUARE D DU221RB 30A, 240V, 2P NON-FUSED, NEMA 3R ENCLOSURE (OR EQUIV.) SOLAREDGE TECHNOLOGIES: SE3800H-US-RGM (240V) GRID TIED 2-POLE 3800 WATTS INVERTER AC MAX OUTPUT CURRENT OF 16A MAX OUTPUT CURRENT 16.89A 1.56 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.71 AMPACITY OF #10 WIRE (THWN-2 @ 90 °C) 40A MAXIMUM AMPACITY 16.89A * 1.56 = 26.34A < 40A CONTINUOUS DUTY AND HIGH IRIDESCENCE FACTOR DC AMPACITY CALCULATION 40A * 1.0 * 0.71 = 28.4A > 16.89A ADJUSTED AMPACITY INVERTER OUTPUT CURRENT 16A CONTINUOUS DUTY FACTOR 1.25 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.88 AMPACITY OF #8 WIRE (USE 75°)50A MAXIMUM AMPACITY 16A * 1.25 = 20.0A < 50A ADJUSTED AMPACITY INVERTER OCPD RATING AC AMPACITY CALCULATION FOR 3.8KW INVERTER 50A * 0.88 = 44.0A > 16A 20A (E) UFER #4 AWG CU GEC 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-5A ELEVATION (N) AC DISCONNECT (E) MAIN SERVICE PANEL ELEVATION SCALE: 3/16"=1'-0"1 (N) INVERTER 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-6 ELECTRICAL CALCS ASSUMPTIONS: HIGH TEMPERATURE = 37 °C LOW TEMPERATURE = -10 °C ADDED TEMPERATURE FOR CONDUIT RUN ON ROOF = 22 °C 90 °C RATED WIRE FOR DC CURRENT 75 °C RATED WIRE FOR AC CURRENT THAT TERMINATES AT A BREAKER ELECTRICAL NOTES: · ALL PV MODULES, ARRAY FRAMING AND RACKING SHALL BE GROUNDED PER MFR'S SPECIFICATIONS. · ALL EQUIPMENT WILL BE UL 1703, UL 1741, OR UL 2703 LISTED AND CERTIFIED. · INTEGRATED GROUNDING IN ACCORDANCE WITH THE RACKING MANUFACTURER INSTALLATION INSTRUCTIONS CAN ONLY BE USED FOR BONDING THE MODULES TO THE RACKING WHERE THE SPECIFIC MODULE CATALOG NUMBER HAS BEEN TESTED TO UL2703 STANDARDS BY AN ACCREDITED NRTL. WHERE THE MODULE CATALOG NUMBER IS NOT PART OF THE RACKING SYSTEM APPROVED MODULE LIST, BOND ALL MODULES AND ALL RAILS USING A UL2703 LISTED LAY-IN LUG SUCH AS ILSCO GBL-4DBT. · ALL WIRE TERMINATIONS, SPLICES AND CONNECTIONS SHALL BE MADE USING A LISTED DEVICE OR ELECTRICAL BOX SUITED FOR THE PURPOSE. ALL WIRES NOT IN CONDUIT TO BE PROVIDED WITH STRAIN RELIEF AT ENTRY INTO JUNCTION BOXES. · PROVIDE AND INSTALL CONDUIT EXPANSION FITTINGS, PER MANUFACTURER'S SPECIFICATIONS, IN CONDUIT RUNS WHERE THERMAL EXPANSION IS 0.25" OR MORE, BASED ON RECORD MAXIMUM AND MINIMUM TEMPERATURES FOR THE SITE (SEE NEC TABLE 310.15(B)(2)(C), AND USING EXPANSION COEFFICIENT OF STEEL. · BOTH ENDS OF ALL METALLIC CONDUIT CONTAINING GROUNDING ELECTRODE CONDUCTORS SHALL BE BONDED PER NEC 250.64(E). · PROVIDE AND INSTALL ALL GROUNDING AS REQUIRED BY NEC ARTICLES 250, 690 AND SYSTEM MANUFACTURER. · INSTALLATIONS WHICH USE TRANSFORMER-LESS INVERTERS - PV WIRE-600V/RHW-2 TYPE IS REQUIRED FOR ALL DC WIRE RUNS IN FREE AIR, OR NOT IN CONDUIT. · EACH CURRENT CARRYING CONDUCTOR IN ALL PV SOURCE CIRCUITS OR PV OUTPUT CIRCUITS SHALL BE DISCONNECTED/ FUSED, WHEN NECESSARY. ·CONTRACTOR SHALL VERIFY EXISTENCE OF UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATIONS. ·ELECTRICAL TRENCH RUNS, WHERE USED, SHALL USE SCHEDULE 40 PVC CONDUIT AND PROVIDE 18" MIN CLEARANCE FROM TOP OF CONDUIT TO GRADE, AND MAGNETIC WARNING TAPE AT 12" BELOW GRADE. 24" CLEARANCE AND SCHEDULE 80 PVC IS REQUIRED IN AREAS WHERE SUBJECT TO VEHICLE TRAFFIC. · CHECK WITH LOCAL JURISDICTION FOR ANY ADDITIONAL FILL AND COMPACTION REQUIREMENTS, SPOILS TREATMENT AND/OR EROSION CONTROL MEASURES PRIOR TO EXCAVATION. · INSTALLATIONS IN LIGHTENING-PRONE LOCATIONS ARE RECOMMENDED TO UTILIZE DC LIGHTENING ARRESTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ·SUPPLY SIDE CONNECTIONS SHALL ONLY BE MADE WITH LISTED AND APPROVED TAPS. ·ALL WIRE RUNS SHALL NOT EXCEED 2% CALCULATED VOLTAGE DROP. ·USE WATERPROOF FITTINGS FOR ALL EXTERIOR CONDUIT. ·GROUNDING CONDUCTOR (DC SIDE OF INVERTER) IS #10 IF IN CONDUIT, OR #6 awg IF EXPOSED AND SUBJECT TO DAMAGE (NEC 690.46). PV MODULE SPECS MAKE MODEL SHORT CIRCUIT CURRENT OPEN CIRCUIT VOLTAGE OPERATING CURRENT OPERATING VOLTAGE NOMINAL POWER 5.135 kW (DC) SOLAR ARRAY: (13) CANADIAN SOLAR CS3N-395MS (395W) WITH (13) SOLAREDGE POWER OPTIMIZERS: P400 WITH (1) SOLAREDGE WAVE 3.8KW INVERTER: SE3800H-US-RGM (1) STRING OF (13) MODULES POWER OPTIMIZER SPECS MAKE MODEL RATED DC POWER MAX INPUT VOLTAGE MPPT OPERATING RANGE MAX ISC INPUT CURRENT MAX OUTPUT CURRENT BUS BAR RATING 100A MAIN BREAKER RATING 100A TOTAL SOLAR BACKFEED NEEDED 20A MAX ALLOWABLE BACKFEED (100A X 120%) - 100A FEEDER BREAKER = 20A ALLOWABLE = 20A SOLAR, SO OK TO CONNECT (PER NEC 705.12) ALLOWABLE SOLAR BACKFEED CALCULATION AT MSP MAX OUTPUT CURRENT 16.89A 1.56 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.71 AMPACITY OF #10 WIRE (THWN-2 @ 90 °C) 40A MAXIMUM AMPACITY 16.89A * 1.56 = 26.34A < 40A CONTINUOUS DUTY AND HIGH IRIDESCENCE FACTOR DC AMPACITY CALCULATION 40A * 1.0 * 0.71 = 28.4A > 16.89A ADJUSTED AMPACITY CALCULATIONS: Vmpp = 380V Vmax = 480V Impp = (13 MODULES) * 395W / 380V = 13.51A Imax = 13.51 * 1.25 = 16.89A INVERTER OUTPUT CURRENT 16A CONTINUOUS DUTY FACTOR 1.25 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.88 AMPACITY OF #8 WIRE (USE 75°)50A MAXIMUM AMPACITY 16A * 1.25 = 20.0A < 50A ADJUSTED AMPACITY INVERTER OCPD RATING AC AMPACITY CALCULATION FOR 3.8KW INVERTER 50A * 0.88 = 44.0A > 16A 20A OPERATING OUTPUT VOLTAGE MAX ALLOWED SYSTEM VOLTAGE NUMBER OF UNITS PER STRING MAX POWER PER STRING INVERTER SPECS RATED AC POWER MODEL MAKE TRANSFORMERLESS, UNGROUNDED MAX INPUT VOLTAGE MAX INPUT CURRENT RATED AC VOLTAGE NOMINAL INPUT VOLTAGE AC VOLTAGE RANGE MAX AC OUTPUT CURRENT AC OVERCURRENT PROTECTION CANADIAN SOLAR CS3N-395MS (395W) 11.44A 44.3V 10.68A 37.0V 395W SOLAR EDGE P400 400 W 80 VDC 8 - 80 VDC 10.1 A 15 A 5 - 60 VDC 480 VDC 8-18 5700 W SOLAR EDGE SE3800H-US-RGM 3800 W YES 480VDC 380VDC 10.5A 240 VAC 211 - 264 VAC 16.0 A 20.0 A 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-6 ELECTRICAL CALCS ASSUMPTIONS: HIGH TEMPERATURE = 37 °C LOW TEMPERATURE = -10 °C ADDED TEMPERATURE FOR CONDUIT RUN ON ROOF = 22 °C 90 °C RATED WIRE FOR DC CURRENT 75 °C RATED WIRE FOR AC CURRENT THAT TERMINATES AT A BREAKER ELECTRICAL NOTES: · ALL PV MODULES, ARRAY FRAMING AND RACKING SHALL BE GROUNDED PER MFR'S SPECIFICATIONS. · ALL EQUIPMENT WILL BE UL 1703, UL 1741, OR UL 2703 LISTED AND CERTIFIED. · INTEGRATED GROUNDING IN ACCORDANCE WITH THE RACKING MANUFACTURER INSTALLATION INSTRUCTIONS CAN ONLY BE USED FOR BONDING THE MODULES TO THE RACKING WHERE THE SPECIFIC MODULE CATALOG NUMBER HAS BEEN TESTED TO UL2703 STANDARDS BY AN ACCREDITED NRTL. WHERE THE MODULE CATALOG NUMBER IS NOT PART OF THE RACKING SYSTEM APPROVED MODULE LIST, BOND ALL MODULES AND ALL RAILS USING A UL2703 LISTED LAY-IN LUG SUCH AS ILSCO GBL-4DBT. · ALL WIRE TERMINATIONS, SPLICES AND CONNECTIONS SHALL BE MADE USING A LISTED DEVICE OR ELECTRICAL BOX SUITED FOR THE PURPOSE. ALL WIRES NOT IN CONDUIT TO BE PROVIDED WITH STRAIN RELIEF AT ENTRY INTO JUNCTION BOXES. · PROVIDE AND INSTALL CONDUIT EXPANSION FITTINGS, PER MANUFACTURER'S SPECIFICATIONS, IN CONDUIT RUNS WHERE THERMAL EXPANSION IS 0.25" OR MORE, BASED ON RECORD MAXIMUM AND MINIMUM TEMPERATURES FOR THE SITE (SEE NEC TABLE 310.15(B)(2)(C), AND USING EXPANSION COEFFICIENT OF STEEL. · BOTH ENDS OF ALL METALLIC CONDUIT CONTAINING GROUNDING ELECTRODE CONDUCTORS SHALL BE BONDED PER NEC 250.64(E). · PROVIDE AND INSTALL ALL GROUNDING AS REQUIRED BY NEC ARTICLES 250, 690 AND SYSTEM MANUFACTURER. · INSTALLATIONS WHICH USE TRANSFORMER-LESS INVERTERS - PV WIRE-600V/RHW-2 TYPE IS REQUIRED FOR ALL DC WIRE RUNS IN FREE AIR, OR NOT IN CONDUIT. · EACH CURRENT CARRYING CONDUCTOR IN ALL PV SOURCE CIRCUITS OR PV OUTPUT CIRCUITS SHALL BE DISCONNECTED/ FUSED, WHEN NECESSARY. ·CONTRACTOR SHALL VERIFY EXISTENCE OF UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATIONS. ·ELECTRICAL TRENCH RUNS, WHERE USED, SHALL USE SCHEDULE 40 PVC CONDUIT AND PROVIDE 18" MIN CLEARANCE FROM TOP OF CONDUIT TO GRADE, AND MAGNETIC WARNING TAPE AT 12" BELOW GRADE. 24" CLEARANCE AND SCHEDULE 80 PVC IS REQUIRED IN AREAS WHERE SUBJECT TO VEHICLE TRAFFIC. · CHECK WITH LOCAL JURISDICTION FOR ANY ADDITIONAL FILL AND COMPACTION REQUIREMENTS, SPOILS TREATMENT AND/OR EROSION CONTROL MEASURES PRIOR TO EXCAVATION. · INSTALLATIONS IN LIGHTENING-PRONE LOCATIONS ARE RECOMMENDED TO UTILIZE DC LIGHTENING ARRESTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ·SUPPLY SIDE CONNECTIONS SHALL ONLY BE MADE WITH LISTED AND APPROVED TAPS. ·ALL WIRE RUNS SHALL NOT EXCEED 2% CALCULATED VOLTAGE DROP. ·USE WATERPROOF FITTINGS FOR ALL EXTERIOR CONDUIT. ·GROUNDING CONDUCTOR (DC SIDE OF INVERTER) IS #10 IF IN CONDUIT, OR #6 awg IF EXPOSED AND SUBJECT TO DAMAGE (NEC 690.46). PV MODULE SPECS MAKE MODEL SHORT CIRCUIT CURRENT OPEN CIRCUIT VOLTAGE OPERATING CURRENT OPERATING VOLTAGE NOMINAL POWER 5.135 kW (DC) SOLAR ARRAY: (13) CANADIAN SOLAR CS3N-395MS (395W) WITH (13) SOLAREDGE POWER OPTIMIZERS: P400 WITH (1) SOLAREDGE WAVE 3.8KW INVERTER: SE3800H-US-RGM (1) STRING OF (13) MODULES POWER OPTIMIZER SPECS MAKE MODEL RATED DC POWER MAX INPUT VOLTAGE MPPT OPERATING RANGE MAX ISC INPUT CURRENT MAX OUTPUT CURRENT BUS BAR RATING 100A MAIN BREAKER RATING 100A TOTAL SOLAR BACKFEED NEEDED 20A MAX ALLOWABLE BACKFEED (100A X 120%) - 100A FEEDER BREAKER = 20A ALLOWABLE = 20A SOLAR, SO OK TO CONNECT (PER NEC 705.12) ALLOWABLE SOLAR BACKFEED CALCULATION AT MSP MAX OUTPUT CURRENT 16.89A 1.56 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.71 AMPACITY OF #10 WIRE (THWN-2 @ 90 °C) 40A MAXIMUM AMPACITY 16.89A * 1.56 = 26.34A < 40A CONTINUOUS DUTY AND HIGH IRIDESCENCE FACTOR DC AMPACITY CALCULATION 40A * 1.0 * 0.71 = 28.4A > 16.89A ADJUSTED AMPACITY CALCULATIONS: Vmpp = 380V Vmax = 480V Impp = (13 MODULES) * 395W / 380V = 13.51A Imax = 13.51 * 1.25 = 16.89A INVERTER OUTPUT CURRENT 16A CONTINUOUS DUTY FACTOR 1.25 MULTIPLE CONDUCTOR FACTOR 1.0 TEMP CORRECTION FACTOR 0.88 AMPACITY OF #8 WIRE (USE 75°)50A MAXIMUM AMPACITY 16A * 1.25 = 20.0A < 50A ADJUSTED AMPACITY INVERTER OCPD RATING AC AMPACITY CALCULATION FOR 3.8KW INVERTER 50A * 0.88 = 44.0A > 16A 20A OPERATING OUTPUT VOLTAGE MAX ALLOWED SYSTEM VOLTAGE NUMBER OF UNITS PER STRING MAX POWER PER STRING INVERTER SPECS RATED AC POWER MODEL MAKE TRANSFORMERLESS, UNGROUNDED MAX INPUT VOLTAGE MAX INPUT CURRENT RATED AC VOLTAGE NOMINAL INPUT VOLTAGE AC VOLTAGE RANGE MAX AC OUTPUT CURRENT AC OVERCURRENT PROTECTION CANADIAN SOLAR CS3N-395MS (395W) 11.44A 44.3V 10.68A 37.0V 395W SOLAR EDGE P400 400 W 80 VDC 8 - 80 VDC 10.1 A 15 A 5 - 60 VDC 480 VDC 8-18 5700 W SOLAR EDGE SE3800H-US-RGM 3800 W YES 480VDC 380VDC 10.5A 240 VAC 211 - 264 VAC 16.0 A 20.0 A 610 S Broadway 06/09/22 SHEET: DRAFTER SIGNATURE PROJECT ADDRESS: REVISION # DATE: 05/12/2022 DRAWING TYPE PENGUIN HOME SOLUTIONS IBARRA, BELEN 610 S BROADWAY, SANTA ANA, CA 92701 (000) 000-0000 21860 VAN BUREN BLVD, BLDG 11, SUITE 101, RIVERSIDE, CA 92518 (888) 488 8001 LICENSE#: C-10 1033658 PV-7 PLACARDS WARNING WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. NEC SECTION LOCATION OF LABEL LABEL TEXT AND APPERANCE NEC SECTION LOCATION OF LABEL LABEL TEXT AND APPERANCE 690.54 ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. 690.56(B) 690.4(D) 705.10 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS FOR THE BUILDING OR STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. THE PLAQUE OR DIRECTORY SHALL BE MARKED WITH THE WORDING “C UTION: MULTIPLE SOURCES OF POWER͘” NY POSTED DIAGRAMS SHALL BE CORRECTLY ORIENTED WITH RESPECT TO THE DIAGRAM'S LOCATION. THE MARKING SHALL COMPLY WITH 110.21(B). 690.13(B) 690.15 705.20 EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED: “PV SYSTEM DISCONNECT” OR EQUIVALENT. 690.53 A PERMANENT READILY VISIBLE LABEL INDICATING THE HIGHEST MAXIMUM DC VOLTAGE IN A PV SYSTEM, CALCULATED IN ACCORDANCE WITH 690.7, SHALL BE PROVIDED BY THE INSTALLER AT ONE OF THE THREE LOCATIONS. 690.31 (D)(2) UNLESS THE PURPOSE IS EVIDENT, THE FOLLOWING WIRING METHODS AND ENCLOSURES THAT CONTAIN PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE MARKED: (1) EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS (2) COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION BOXES (3) CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. 690.13(B) 690.15(C) 705.12 (B)(3)(2) 705.12 (B)(3)(3) 690.56 (C) A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER. PHOTOVOLTAIC SYSTEM AC DISCONNECT PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT (2) A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH THAT INCLUDES THIS WORDING. THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED BACKGROUND . BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF A BUILDING WITH A ROOF AND SHALL INCLUDE THE FOLLOWING WORDS: THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 16 AMPS 240 VOLTS RAPI' SHUT'OWN SWIT&H )OR SOLAR P 9 S<STEM WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC DC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT MAXIMUM DC VOLTAGE OF PV SYSTEM SOLAR PV DC CIRCUIT PHOTOVOLTAIC POWER SOURCE (1) BUILDING WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS WITH BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND PV SYSTEM WITH NO RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING EACH DIFFERENT PV SYSTEM AND DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID SHUTDOWN SWITCH IS OPERATED. PHOTOVOLTAIC AC DISCONNECT CAUTION: MULTIPLE SOURCES OF POWER WITH DISCONNECTS LOCATED AS SHOWN NS BROADWAY NE& LA%ELING RE4UIREMENTS MAIN SERVICE PANEL "YOU ARE HERE" PV AC DISCONNECT SWITCH PV DC DISCONNECT ON INVERTER (NEAR MSP) MSP AC INV JB 610 S Broadway 06/09/22