Loading...
HomeMy WebLinkAbout5313 W Henderson Pl - 101121650 & 20185409 - PlanPAGE REV: A3 10/29/2024 MARIA VALADEZ 5313 W HENDERSON PL, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024.02.28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX SURGE PROTECTOR TO BE INSTALLED PER MANUFACTURER AND PANEL BOARD SPECS. PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-3.2 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CALCS PV-4.2 BACKUP LOAD CALCS PV-4.3 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE LTD: LR5-54HABB-400M TESLA: POWERWALL 3 1707000-XX-Y WITH STANDOFF TO FRAMING: SNR-DC-01249 [FLAT, FLUSH MOUNT ( ROLLED COMP/ MEMBRANE/ FOAM) 1 LAG OMNIBASE]; ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING, SNR-DC-00339 1707000-XX-Y, 27 kWh (MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE PANEL WITH 50 AMP MAIN BREAKER TO BE REPLACED WITH NEW 125 AMP MAIN PANEL WITH 125 AMP MAIN BREAKER AND 225 AMP BUSBAR. MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). MODULES, ARE CLASS A FIRE RATED. CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg#: 101121650 Elec#: 20184540 Approvals: Elec: M Smith 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46PLPLPLPLPLPLPLPLPLPL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 2538 SQFT.  TOTAL PV ARRAY AREA: 441.4 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 = 17.4% ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN  ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM  EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER  SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE  BASED ON LARGE/SCALE FIRE TESTING. POWERWALL ENERGY  STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANEL ELECTRIC VEHICLE  SUPPLY EQUPMENTEV MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE  INTERIOR EQUIPMENT  SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMA GROUNDING  ELECTRODE ENERGY STORAGE  SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE  1 COMMUNICATION  WIRESAM MD MICROGRID  INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEMPV LOAD CENTERLC LEGEND  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN RAIL STANDOFFS &  FOOTINGS SOLAR  MODULES SITE PLAN - SCALE = 0'-0 3/64" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) SE MP AC INV INV W HENDERSON PL GP RSD MD ROOF PATHWAYS (3' TYP) AC (E) FENCE  (E) GATE (TYP.) EXTERNAL RAPID SHUTDOWN SWITCH RSD A A A A A A A A B B B B B B B C C C C C C (E) DETACHED  STRUCTURE (E) PATIO ARRAY  PITCH PV AREA  (SQFT) AR-01 6° 126.1 AR-02 18° 315.3179° TRUE  AZIM MAG  AZIM 167°179° 167° NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE  INSTALLED MODULE PER NEC 690.12 AC AC    10/29/2024 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. LAG SCREW: 2.5"  MIN EMBEDMENT INTO FRAMING PV-3.0 LAYOUT SOLAR MODULE SNAPNRACK  RACKING 4" MODULE ELEVATION DETAIL - SCALE: NTS INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED  PRIOR TO PROCEEDING W/ INSTALLATION. * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF  ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS  NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE  REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF  ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max  Span OC  Spacing Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 FLAT, ROLLED COMP  [FLUSH MOUNT] -  OMNIBASE 1 LAG - UR 1-Story 2X6 RAFTERS 7'-1" 24" ULTRA RAIL, ATTACHMENT DETAIL,  OMNIBASE WITH STANDOFF TO FRAMING:  SNR-DC-01249  [FLAT, FLUSH MOUNT (  ROLLED COMP/ MEMBRANE/ FOAM) 1 LAG  OMNIBASE] 6'-0" 2'-4" 6'-0" 2'-3" STACKED AR-02 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X4 PRE-FABRICATED TRUSSES 7'-7" 24" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 6'-0" 2'-4" 6'-0" 2'-3" STACKED SEE SITE PLAN FOR NORTH ARROW D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 179° PITCH: 6° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 179° PITCH: 18° SOLAR MODULE SNAPNRACK RACKING AND  STANDOFF MODULE ELEVATION DETAIL - SCALE: NTS 7" 6' TYP 30'-2" 11'-4" 8"20'-6" 1'-6" 1'-2" 6' TYP 22'-8" 5'-8" 3'3'-4" 1'-6" 1' FASTENERS:  (1) 5/16" DIA S.S. UMBRELLA  SCREW: 2.5" MIN EMBEDMENT  INTO FRAMING 10/29/2024 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP PV-3.1 MOUNTING DETAIL DESCRIPTION: UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS 15 8" 11 2" 11 2" 21 4" SNAPNRACK ULTRA RAIL STANDARD STANDOFF  ON OMNIBASE FOR MOUNTING TO VARIOUS  ROOF TYPES REFER TO SNAPNRACK ENGINEERING CHARTS  FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON  CHART SHOULD MATCH "BIN" NUMBER ON THIS  DRAWING 5 16"Ø S.S. LAG SCREW MUST EMBED A MIN. OF  21 2" INTO STRUCTURAL MEMBER REFER TO SNAPNRACK INSTALLATION MANUAL  FOR  5 16"Ø HARDWARE TORQUE SPECIFICATIONS SNAPNRACK OMNIBASE CAN MOUNT IN ANY  ORIENTATION ON THE ROOF RAILS CAN MOUNT ON ANY SIDE OF THE  STANDOFF POST FOR LEVELING DETAILS, REFER TO SNAPNRACK  DETAIL DRAWING "SNR-DC-00334 ULTRA RAIL,  COMPONENT DETAIL, LEVELING SPACER ON  STANDOFF" AND "SNR-DC-00447 ULTRA RAIL,  COMPONENT DETAIL, UR LEVELING SPACER" *A POURED SEALANT-STYLE FLASHING MAY BE  USED WHEN INSTALLED PER THE  MANUFACTURER'S SPECIFICATIONS INSTALLED ATTACHMENT DETAIL SNAPNRACK OMNIBASE EXPLODED SNAPNRACK, OMNIBASE SNAPNRACK STANDOFF, LENGTH VARIES SNAPNRACK, UR STANDOFF CLAMP ASSEMBLY. VARIES FOR FLUSH AND TILT APPLICATIONS  MODULE HEIGHT OFF ROOF, RANGE: UR-40: 73 4" - 87 8" UR-60: 83 8" - 91 2" (SHOWN FOR 7" STANDOFF, ADJUST PER STANDOFF LENGTH) OMNIBASE, TOP BASE HEIGHT: .70 4.00 3.00 7" STANDOFF SHOWN, LENGTH VARIES SNAPNRACK, ULTRA RAIL (UR-40 SHOWN) SNAPNRACK, ULTRA RAIL (UR-40 SHOWN) STRUCTURAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. *FLASH STANDOFF APPROPRIATELY. 1"Ø VENT PIPE FLASHING SHOWN, VARIES BY APPLICATION SNAPNRACK RUBBER RAIN COLLAR FOR 1"Ø CONE FLASHINGS 5 16"Ø S.S. LAG SCREW WITH S.S. FLAT WASHER. CHOOSE LENGTH FOR PROPER EMBEDMENT 5 16"Ø S.S. LAG SCREW WITH S.S. FLAT WASHER. CHOOSE LENGTH FOR PROPER EMBEDMENT STRUCTURAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. (1) 5/16" Ø S.S. LAG SCREW:  2.5" MIN EMBEDMENT INTO  FRAMING SNR-DC-01249_UR_OMNI_STANDOFF TO RAFTER 10/29/2024 5313 W Henderson Pl2/5/2025 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air 2 Inverter Input (2) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 2a Inverter Input (4) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Backup gateway/ Generation panel Output (2) 1 AWG THHN/THWN-2 (1) 1 AWG THHN/THWN-2 6 AWG THHN/THWN-2 1-1/4 EMT 5 Backup load Output (4) 6 AWG THHN/THWN-2 (4) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 1-1/4 EMT (4) 6 AWG THHN/THWN-2 (2) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 PAGE REV: B 1/29/2025 MARIA VALADEZ 5313 W HENDERSON PL, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024.02.28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 NEW125A MAIN BREAKER END FED NEW 125A MAIN PANEL 225A BUS NEW 200A BACKUP GATEWAY 1841000-X1-Y 4 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 1 OF 7 MODULES 3 MODULE LEVEL RAPID SHUTDOWN DEVICES LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 2 OF 8 MODULES 3 MODULE LEVEL RAPID SHUTDOWN DEVICES 1 1 2a J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 1 OF 6 MODULES 2 MODULE LEVEL RAPID SHUTDOWN DEVICES 12 POINT OF INTERCONNECTION:705.12(B)(3)(2), GATEWAY BREAKER AT OPPOSITE END OF BUSBAR METER NUMBER: 222013-570957 REPLACE EXISTING 50 MAIN PANEL WITH NEW 125A MAIN PANEL 125A MAIN BREAKER AND 225A BUS BAR EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED = 120A USED FOR INTERCONNECTION CALCULATIONS M 125A (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A RSD TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 RSD TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 NEW 225 A GENERATION AND BACKUP LOAD PANEL (N) (2) 60A (PV+ESS) BREAKER 4 60A 60A FACILITY GROUND (E) RELOCATED BACKUP LOADS 5 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M 400 W OPEN CIRCUIT VOLTAGE 37.05 V MAX POWER VOLTAGE 30.94 V SHORT CIRCUIT CURRENT 13.72 A GENERAL NOTES: GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER CONDUCTORS IN TWO SEPARATE CONDUITS. B 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.1 ELECTRICAL CALCS ELECTRICAL CALCS SYSTEM INFORMATION 8.4 KW DC PHOTOVOLTAIC SYSTEM      (15) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y      (6) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y SYSTEM OCPD SIZE (COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  96 A X 1.25 = 120 A → 125 A OVERCURRENT PROTECTION GATEWAY SYSTEM AC WIRE SIZING MAX AC OUTPUT CURRENT = 125 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 145A = 131.95A TERMINAL RATING[110.14(C)] = 1 AWG, 75°C RATED = 130A 130A < 131.95A   TERMINAL RATING GOVERNS CONDUCTOR SIZING 125A < 130A   1 AWG AMPACITY OK THEREFORE 1 AWG IS SUFFICIENT. ALLOWABLE BACKFEED ALLOWABLE BACKFEED = (MAIN PANEL RATING) X 1.2 - (MAIN BREAKER RATING) =  225A X 1.2 - 125A = 145A 125A ≤ 145A → INTERCONNECTION MEETS 705.12(B)(3)(2) REQUIREMENTS. INVERTER INFORMATION 6.0 KW DC PHOTOVOLTAIC SYSTEM      (15) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=  13.72 A X 1.25 X 1.25= 21.44A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 0.8 X 40A = 29.12A TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A 29.12A < 35A    TERMINAL RATING GOVERNS CONDUCTOR SIZING.          21.44A < 29.12A   10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =          0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] =         6 AWG,75°C RATED = 65A 65A < 68.25A   TERMINAL RATING GOVERNS CONDUCTOR SIZING.         60A < 65A   6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X  (# MODULES / STRING) = {[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 8 = 317 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 13.72 A X 2 = 34.3A INVERTER INFORMATION 2.4 KW DC PHOTOVOLTAIC SYSTEM      (6) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3  1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  LOAD)[690.8(B)(1)]=  13.72 A X 1.25 X 1.25= 21.44A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE  310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG,  RATED = 35A 35A < 36.4A    TERMINAL RATING GOVERNS CONDUCTOR SIZING.         21.44A < 35A   10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE  310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =          0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] =         6 AWG,75°C RATED = 65A 65A < 68.25A   TERMINAL RATING GOVERNS CONDUCTOR SIZING.         60A < 65A   6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X  (# MODULES / STRING) = {[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 6 = 238 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 13.72 A X 1 = 17.15A 5313 W Henderson Pl2/5/2025 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL DEMAND  LOAD 1 20A-1P KITCHEN 1500 VA 2 20A-1P KITCHEN 1500 VA 3 20A-2P OTHER 3840 VA 5 15A-1P ROOMS 1500 VA 6 15A-1P ROOMS 1500 VA 7 30A-2P DRYER 5760 VA PAGE REV: A3 10/29/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 BACKUP LOAD CALCS ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE  PANEL. BACKED UP LOADS CALCULATION: (5760 VA)/ 240V = 24 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 40A. (MAX LOADS OUTPUT) X (CONTINUOUS LOADS) =  24 A X 1.25 = 30A BACKED UP LOADS PANEL BREAKER = 125A 30 A < 125A. THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. AC WIRE SIZING FOR BACKUP LOADS PANEL MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 24 A X 1.25 = 30 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A 35A < 36.4A    TERMINAL RATING GOVERNS CONDUCTOR SIZING. 30A < 35A   10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT.      PV-4.2 BACKUP LOAD  CALCS 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 (N) GATEWAY  FEEDER BREAKER MAIN BREAKER 125 NEW PV+ESS  BREAKER60 FUTURE BACKUP LOAD  PANEL 30LIGHTS /RECEPTABLES 151520ROOMS LIGHTS /RECEPTABLES DRYER NEW 225/125A   MAIN PANEL PANEL SCHEDULE PANEL SCHEDULE PV-4.312520KITCHEN NEW PV+ESS  BREAKER6020OTHER 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP ENERGY STORAGE SYSTEM  DISCONNECT LABEL LOCATION: ENERGY STORAGE SYSTEM DISCONNECT PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022  ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY  SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING  EFFECTIVE WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR  WIRING METHOD AND SHALL NOT BE HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE  ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT  SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2)CAUTION  5313 W HENDERSON PL, SANTA ANA, CA, 92704 SOLAR PANELS ON ROOF PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) AC DISCONNECT INVERTER & ENERGY STORAGE  (EXT) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT INVERTER 2 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 BACKUP GATEWAY GENERATION AND BACKUP LOADS PANEL  SERVICE ENTRANCE AND  GATEWAY FEEDER BREAKER  RAPID SHUTDOWN SWITCH 5313 W Henderson Pl2/5/2025 PAGE REV: A3 10/29/2024 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.1 #ESTAMP LABEL LOCATION: BACKUP LOAD PANEL NO ADDITIONAL  LOADS TO BE  ADDED ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS VOLTAGE VAC LABEL LOCATION: MAIN PANEL. 120 240 CEC 2022 - PW3 PER CODE(S): CEC 2022: NEC 706.15(C) 5313 W Henderson Pl2/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] 5313 W HendersonPl2/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 41.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) 5313 W HendersonPl2/5/2025                    !  "  # $$% &  !  " '() *$ ' *  " +  ' ,(-./)0  1'     * #1  $       1'  #    2 $" +)  $" + %   #$% & ! 1' )+  ! %     #    ')      #2* $" +1   *  $" +      3 # 43 5 )6 57...*  57...&* 5#+# &8 ! 9 7 '" *     "   1  " " %    5  # !    )+  9  *    7 ':$" - # ;.<2=><2?0   (1           "   +    "  + #  " '  " '+  +  +    ,22  E  F  '"  "G         H *8 '  "   +    .Sep 16, 20205 .>-2=&>2?0  .&2=2?%!  "   1    +  &2@9=2@?2@9=2@?   +  /%-; #  #   #'A3B1$% &0  )  0%&71C$><;;>>&<$".+ *#. * # 8 # =" ?&.-2"=/)?=&.;2*#?  " 'D  '+#/) *#/  * #  # .2=.>2? * # 8 .>2=&;.<><2? * #  # &.<2=<.>>2?++ )  " ')  " ++   7   %   # %  0   %  + +)3D %/)0  !   %/)0   1: !' + D  '+ D ) :  + D   ) #   )     !   )   = +  ) #   ?%!  0    %!  + 5313 W HendersonPl2/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547-2018 IEEE 1547.1-2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547-2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547-2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547-2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547-2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547-2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547-2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547-2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA-V2.0 (HECO) Part II B HIGH FREQUENCY RIDE-THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA-V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547-2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547-2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547-2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547-2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547-2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547-2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547-2018 IEEE 1547.1-2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547-2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547-2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547-2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547-2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547-2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547-2018 VOLTAGE-ACTIVE POWER (VOLT-WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547-2018 TEST FOR FREQUENCY-DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY—ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA-V2.0 (HECO) Part II C TEST FOR FREQUENCY-DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY—BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA-V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547-2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547-2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547-2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547-2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547-2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547-2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547-2018 5313 W HendersonPl2/5/2025 5313 W Henderson Pl2/5/2025 Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 isdesignedformassproduction,fastandef𿿿cientinstallations,easysystemexpansion,andsimpleconnectiontoanyelectrical service. 22024Powerwall 3 Datasheet Solar Technical Speci￿cations Maximum Solar STC Input 20 kW WithstandVoltage 600 V DC PVDCInputVoltageRange 60 — 550 V DC PVDCMPPTVoltageRange 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (Imp)13 A 5 Maximum Short Circuit Current per MPPT (Isc)15 A 5 Powerwall3 Technical Specifications 1 Typical solar shifting use case. 2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. 3 TestedusingCECweightedef𿿿ciencymethodology. 4 ThecustomerisexpectedtoprovideinternetconnectivityforPowerwall3;cellularshouldnotbeusedastheprimarymodeof connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 WheretheDCinputcurrentexceedstheMPPTrating,ajumpercanbeusedtocombinetwoMPPTsintoasingleinputto intake DC current up to 26 A IMP / 30 A ISC. Battery Technical Speci￿cations Nominal Battery Energy 13.5 kWh AC 2 MaximumContinuousDischargePower 11.5 kW AC MaximumContinuousChargePower 5 kW AC OutputPowerFactorRating 0-1(GridCodecon𿿿gurable) MaximumContinuousCurrent 48 A Maximum Output Fault Current 10 kA LoadStartCapability(1s)185 A LRA PowerScalability Up to 4 Powerwall 3 units supported SystemTechnical Speci￿cations ModelNumber 1707000-xx-y NominalGridVoltage(Input&Output)120/240 VAC GridType Split phase Frequency 60 Hz OvercurrentProtectionDevice 60 A SolartoBatterytoHome/GridEf￿ciency 89% 1,2 SolartoHome/GridEf￿ciency 97.5% 3 SupportedIslandingDevices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4) HardwareInterface Drycontactrelay,RapidShutdown(RSD)certi𿿿edswitch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation MonitorInterrupter(IMI),PVRapidShutdown(RSD)using TeslaMid-CircuitInterrupters CustomerInterface TeslaMobileApp Warranty 10 years 5313 W Henderson Pl2/5/2025 5313 W Henderson Pl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eb 3, 2020:!!761;!: ;: ;: , 3 4 3 <) =2::5,3< 2#15()<== . )( *C . */3.%D//  . )( * . )( //    . --8  (/. 88  .#1$+  8  . E8 *  - ( .(.3+  .( -8. 4   ,.4.   / (/.     .3 .A 8 '  -2- ./- .3 44428#14 ..3 2 23'$  3( .$  (  .$ / /"C   ' -8( .  (  .E '*- (/ C % */ C  E -8 ../- .C  .  3( . .  (  .  '  .  (  .< / . ( 3 ( 8 =.'.- . ( (   .'.- . (/( (  */( . / 8 / *(.38  . .    (4  . *  . *:6-. 5313 W HendersonPl2/5/2025 32024Powerwall 3 Datasheet Mechanical Speci￿cations Dimensions 1099x609x193mm(43.25x24x7.6in) Weight 130 kg (287 lb) MountingOptions Floor or wall mount Powerwall3 Technical Specifications Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 OperatingHumidity(RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated EnclosureRating NEMA3R IngressRating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) PollutionRating PD3 OperatingNoise@1m < 50 db(A) typical <62db(A)maximum Compliance Information Certi￿cations UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 GridConnection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) FireTesting Meetstheunitlevelperformancecriteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 193 mm 1099 mm 42024Powerwall 3 Datasheet Electrical Speci￿cations Model MCI-1 MCI-2 NominalInputDCCurrentRating(IMP)13 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A MaximumSystemVoltage(PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Speci￿cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) EnclosureRating NEMA4X/IP65NEMA4X/IP65 RSDModule Performance MaximumNumberofDevicesperString 5 5 Control PowerLineExcitation PowerLineExcitation PassiveState Normally Open Normally Open MaximumPowerConsumption 7 W 7 W Warranty 25 years 25 years — TheSolarShutdownDeviceisaMid-CircuitInterrupter(MCI)andispartofthePVsystemrapidshutdown(RSD)functionin accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Speci￿cations ElectricalConnections MC4Connector MC4Connector Housing Plastic Plastic Dimensions 125x150x22mm (5x6x1in) 173x45x22mm (6.8x1.8x1in) Weight 350 g (0.77 lb) 120 g (0.26 lb) MountingOptions ZEP Home Run Clip M4Screw(#10) M8Bolt(5/16") Nail / Wood screw Wire Clip Compliance Information Certi￿cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSDInitiationMethod ExternalSystemShutdownSwitchor Powerwall 3 Enable Switch 7MaximumSystemVoltageislimitedbyPowerwallto600VDC. UL3741PVHazardControl (andPVRSA)Compatibility SeePowerwall3InstallationManual 5313 W Henderson Pl2/5/2025 52024Powerwall 3 Datasheet Gateway 3 8 Only Eaton CSR or BWH main breakers are 25 kA rated. Performance Speci￿cations ModelNumber 1841000-01-y NominalGridVoltage 120/240 V AC GridCon￿guration Split phase GridFrequency 60 Hz ContinuousCurrent Rating 200 A Maximum Supply Short Circuit Current 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker 8 IECProtectiveClass Class I Overvoltage Category Category IV Mechanical Speci￿cations Dimensions 660x411x149mm (26x16x6in) Weight 16.3 kg (36 lb) Mountingoptions Wall mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) OperatingHumidity(RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated EnclosureType NEMA3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 107.1, CSA 22.2 29 Emissions FCC Part 15, ICES 003 — Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based control, and backup operation. 411 mm 660 mm 149 mm AC Meter Revenue accurate (+/- 0.5%) Communication CAN UserInterface Tesla App BackupTransition Automatic disconnect for seamless backup Overcurrent ProtectionDevice 100–200 A Service entrance rated Eaton CSR, BWH, or BW, or SquareDQOMbreakers InternalPanelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or SquareDHOMbreakersrated to 10–125A Warranty 10 years 62024Powerwall 3 Datasheet Backup Switch 9Breakermaximumsupplyshortcircuitcurrentratingmustbeequaltoorgreaterthantheavailablefaultcurrent. Performance Speci￿cations ModelNumber 1624171-xx-y ContinuousLoadRating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 9 Communication CAN AC Meter Revenue accurate (+/- 0.5%) ExpectedServiceLife 21 years Warranty 10 years Mechanical Speci￿cations Dimensions 176x205x74mm(6.9x8.1x2.9in) Weight 2.8 lb MeterandSocketCompatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override 10 Reset button ConduitCompatibility 1/2-inch NPT Environmental Speci￿cations Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) EnclosureRating NEMA3R PollutionRating PD3 Compliance Information SafetyStandards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 Emissions FCC, ICES 10Manuallyoverridesthecontactorpositionduringaserviceevent. — The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 204.86 74 176 mm 205 mm 74 mm 5313 W Henderson Pl2/5/2025 72024Powerwall 3 Datasheet Backup Gateway 2 Performance Speci￿cations ModelNumber 1232100-xx-y ACVoltage(Nominal)120/240 V Feed-inType Split phase GridFrequency 60 Hz CurrentRating 200 A Maximum Supply Short Circuit Current 10 kA 11 Overcurrent Protection Device 100 - 200 A, Service entrance rated 9 Overvoltage Category Category IV Internal Primary AC Meter Revenue accurate (+/- 0.2%) Internal Auxiliary AC Meter Revenue accurate (+/- 2%) Primary Connectivity Ethernet, Wi-Fi SecondaryConnectivity Cellular (3G, LTE/4G) 12 Mechanical Speci￿cations Dimensions 660x411x149mm (26x16x6in) Weight 20.4 kg (45 lb) Mountingoptions Wall mount, Semi-Đushmount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) OperatingHumidity(RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated EnclosureType NEMA3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 411 mm 660 mm 149 mm 11 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 12 Cellular connectivity subject to network operator service coverage and signal strength. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. Inthissystemcon𿿿guration,Powerwall3actsastheSiteController,withtheBackupGateway2SiteControllerdisabled. UserInterface Tesla App OperatingModes Support for solar self- consumption, time-based control, and backup BackupTransition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOMbreakersrated10- 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 82024Powerwall 3 Datasheet Powerwall3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup 5313 W Henderson Pl2/5/2025 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 5313 W HendersonPl2/5/2025 Service Voltage 240 Section 220.82 Dwelling Unit Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 15.63 3750 Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 1500 1500 1000 600 1000 1600 5760 3840 Amps Box B (VA) 76.25 18300 Total VA from Parts #1 and #2 combined:Box A + Box B =22050 Total VA 22050 First 10000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =12050 12050 x 40% =4820 VA Adding First 10000 VA, if possible 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:14820 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:61.75 Amps Part #3 - Section 220.82(C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:0 VA 100% of all the Heating or A/C loads in Amps:0.00 A VA Volts Amps Parts #1 & #2 14820 240 61.75 Part #3 0 240 0.00 Total VA for all Parts:14,820 Totals Service/Feeder Load 61.75 Dedicated circuit Dedicated circuit Article 220 - Dedicated Backup Panel Calculation Job Code 5313 W Henderson Pl Santa Ana, CA 92704 109R-313VALA Building Square Footage VA (watts)Amps House 1250.00 3750 15.63 Total for Part #1: Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Dryer OTHER Totals for Part #2: Totals from all Parts 5313 W Henderson Pl2/5/2025 Section 220.82 Dwelling Unit Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 15.63 3750 Part #2 - Section 220.82 Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A 5760 N/A 3840 N/A N/A N/A N/A Amps Box B (VA) N/A 76.25 18300 Total VA from Parts #1 and #2 combined:Box A + Box B =22050 Total VA 22050 First 10,000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =12050 12050 x 40% =4820 VA Adding First 10,000 VA 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:14820 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:61.75 Amps Part #3 - Section 220.82 (C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:0 VA 100% of all the Heating or A/C loads in Amps:0.00 A VA Volts Amps Parts #1 & #2 14820 240 61.75 Part #3 0 240 0.00 Total VA for all Parts:14,820 Totals Service/Feeder Load 61.75 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 1250 Article 220 - Service/Feeder calculation for (address): 5313 W Henderson Pl Santa Ana, CA 92704 Building VA (watts) 3750 Amps 15.625 Job Code 109R-313VALA Totals from all Parts Dedicated circuit Total for Part #1: Refrigerator(s) Microwave(s) Totals for Part #2: Dryer OTHER 5313 W Henderson Pl2/5/2025 Bus Rating:225 Main Rating:125 0%0% Not Fed by other panels Feeds: Panel 2 61.75 0.00 61.75 Bus Rating:225 Main Rating:125 100%100% Itemized House and 240V Loads for Panel: (VA) 1500 1500 1500 1000 600 1000 1600 5760 3840 Fed by: Panel 1 61.75 61.75 Load Calc: (This Panel) Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Dryer OTHER Panel 2 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Laundry Appliance Circuit - 1 Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Load Calc: (This Panel) Total Load Calc: Total Load Calc: 5313 W Henderson Pl2/5/2025 STRUCTURAL CERTIFICATION REPORT Roof-mounted Solar Panels October 16, 2024 To: Sunrun Re: Maria Valadez 1800 Ashton Blvd 5313 W Henderson Pl Lehi, UT 84043 Santa Ana, CA 92704 AHJ: Santa Ana (City), CA Sunrun proposes to install new roof-mounted solar panels at this residence and asked Right Angle Engineering to review the existing structure for suitability. This letter summarizes the methods that were used to survey, evaluate, and certify the existing roof framing and the attachment of the new solar panels to it. STRUCTURAL DESIGN Building Code:California Residential Code 2022 Design Standards:ASCE 7-16 Snow:Ground: pg= 0.0 psf | Flat Roof: pf= 0.0 psf | Sloped Roof: ps= 0.0 psf Wind:Ultimate Wind Speed = 96.0 mph | Exposure = C Seismic:Risk Category = 2 | Seismic Design Category = A | Site Class = D STRUCTURE Field Technicians from Sunrun visited the site and observed the existing structure : Array Name Panel Quantity Roof Framing Material Pitch Array 1 6 2x6 Rafter| 24" o.c.Rolled Shingle Roof 6° Array 2 15 Pre-Manufactured Truss (2x4) Truss| 24" o.c.Rolled Shingle Roof 18° ANCHORAGE The solar panel anchorage shall be installed according to the manufacturer's most current installation manual. The attachment configuration should match the certified building plans. The solar panels should be mounted parallel (max 5 inches) to the roof surface. Array Name Connection Type Fastener Max Anchorage Spacing Array 1 OmniBase Tilt Mount 5/16” lag screw (2.5" embedment) into roof substructure 72" Array 2 OmniBase Tilt Mount 5/16” lag screw (2.5" embedment) into roof substructure 72" Installation Instructions Solar panels and the equipment shall be installed per the manufacturer's installation specifications. Improper installation will void this certification. If deviations from the approved structural plans occur, Right Angle Engineering must be notified. Prior to installation, the installer should: •Confirm that the existing structure matches the information provided in the site survey, the approved installation plans and this certification. •Identify discrepancies between this certification and the approved installation plans. If found, then this certification shall govern. •Identify structural elements that are dangerous (cracked, broken, excessive sag, signs of overstress, rot, decay, fire, water). If found, installation shall cease until those elements are adequately abated and made to comply with the referenced building code. •Verify that both the existing structure and the solar addition has been permitted through the AHJ. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 1 of 9 5313 W Henderson Pl2/5/2025 STRUCTURAL CERTIFICATION I certify the addition of solar panels on the roof of this structure does not cause the structure to become unsafe or make it generally less compliant with the life-safety requirements of the referenced building code. Based on the evaluation methods described below, for the loads that exist at this site, the existing framing will safely support the new solar panels if they are installed and attached correctly. Electrical design is not included in this certification. Array Name Certification Method Retrofits Array 1 Stress analysis California Residential code 324.4.1 None required Array 2 Stress analysis California Residential code 324.4.1 None required Regards, 10/16/2024 Robert D. Smythe, P.E. Right Angle Engineering 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 2 of 9 5313 W Henderson Pl2/5/2025 Job Details Roof Snow Load - ASCE 7-16 Ground Snow Load (pg) Section 7.2 0.0 psf Exposure Factor (Ce) Table 7.3-1 0.9 Thermal Factor (Ct) Table 7.3-2 1.1 Importance Factor (Is) Table 1.5-2 1 Flat Roof Snow Load (pƒ) Equation 7.3-1 0.0 psf Non-Slippery Surface Slope Factor (Cs) Figure 7.4-1 1 Slippery Surface Slope Factor (Cs) Figure 7.4-1 1 Roof Snow Load Equation 7.4-1 0.0 psf Reduced Snow Load (Slippery Surface) Equation 7.4-1 0.0 psf Design Criteria Wind Speed (Vult) Local Design Criteria 96.0mph Exposure Category C Risk Category 2 Mean Roof Height 20 ft Roof Type Gable Roof Building Type Enclosed Roof Live Load Existing Roof Live Load ASCE 7-16 Table 4.3-1 20 psf 1Roof Dead Load Rolled Shingle Roof 1.5 psf No Drywall 0.0 psf 5/8" Plywood Sheathing 2.0 psf Solar Panel Array 2.74 psf Roof Framing 1.57 psf Dead Load Without Panels 6.27 psf Insulation 1.2 psf 1Roof Dead Load is taken from the worst case scenario dead load from all arrays of the job in order to provide a more conservative evaluation. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 3 of 9 5313 W Henderson Pl2/5/2025 Array 1 Array Details Roof Framing 2x6 Rafter DF No.2 Spacing 24.0" Beam Span 6.0' Roof Pitch 6° Solar Rails UR-40 Panel Quantity 6 Panel Array Area 129.81 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type OmniBase Tilt Mount 5/16” lag screw Shear Capacity NDS 190.0 lbs Pullout Capacity NDS 665.0 lbs Velocity Pressure Equation 26.10-1 (Kz=0.9, Kht=1, Kd=0.85, Ke=1.0) 15.61 psf GCP Zones 1'/1 2 3 GCp Figure 30.3-(2A-5B)-1.56 -2.12 -2.84 Design Pressure Up [psf] Equation 29.4-7 ga=0.53 gE=1.0,-16 -17.7 -23.7 Factored Design Pressure Up [psf] ASD LC (.6D + .6W) -8.0 -9.0 -12.6 Exposed Design Pressure Up [psf] ga=0.53 gE=1.5, -19.5 -26.5 -35.5 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]83.5 74.3 52.9 Maximum Connection Spacing [in]320 285 203 Maximum Rail Span [in]80 80 78 Maximum Rail Cantilever [in]24 24 24 Design Connection Spacing [in] *Adjusted 72 72 72 Design Connection Spacing (exposed) [in]72 72 72 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 4 of 9 5313 W Henderson Pl2/5/2025 Design Ratio Member ID Axial Momentz Sheary Combined Slenderness Deflection Status 1 0.0 0.047 0.052 0.042 0.044 0.009 Pass 2 0.001 0.047 0.046 0.047 0.044 0.029 Pass Member Design Capacity (LRFD) Member ID FI b(ksi)FI t(ksi)FI v(ksi)FI c(ksi)FI cp(ksi)EI(ksi)Emin I(ksi) 1 2.324 1.292 0.311 2.566 0.939 1600.0 1041.216 2 2.324 1.292 0.311 2.566 0.939 1600.0 1041.216 Node Coordinates ID X Coordinate Y Coordinate 1 0.000 0.000 2 6.000 0.631 3 -1.500 -0.158 Members ID Node A Node B Section Node A Fixity Node B Fixity Length 1 1 2 1 FFFFFF FFFFFF 6.033 2 3 1 1 FFFFFF FFFFFF 1.508 Supports ID Node ID Restraint Code 1 2 RFFRRR 2 1 FFFFFR Materials ID Name Young's Modulus Density Poisson's Ratio 1 NDS - Table 4A - DOUGLAS FIR-LARCH - No.2- 2in & wider 1600.000 33.308 0.400 Sections ID Name Depth Width Shear Area Z Shear Area Y Torsion Radius 1 1.5 x 5.5 6.000 1.500 7.502 7.500 1.495 ID Centroid Y Centroid Z Area Y-Axis Mol Z-Axis Mol Torsion Constant 1 0.750 3.000 9.000 1.688 27.000 5.687 Point Loads ID Load Group Member Position %Y Magnitude 1 Solar-Snow 1 8.333%0.000 2 Solar 1 8.333%-0.032 Member Distributed Loads ID Load Group Start Position End Position Member Y Magnitude 1 Dead Load 0.000%100.000%2 -0.013 2 Dead Load 0.000%100.000%1 -0.013 3 Roof Live Load 0.000%66.667%2 -0.040 4 Roof Live Load 95.371%100.000%1 -0.040 5 Snow Load 0.000%66.667%2 0.000 6 Snow Load 95.371%100.000%1 0.000 Load Combinations ID Name Dead Load Factor Snow Load Factor Solar Factor Solar-Snow Factor Roof Live Load Factor 1 1. 1.4D 1.4 0 1.4 0 0 2 3. 1.2D + 1.6Lr 1.2 0 1.2 0 1.6 3 3. 1.2D + 1.6S 1.2 1.6 1.2 1.6 0 4 4. service loads A 0 1 0 1 0 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 5 of 9 5313 W Henderson Pl2/5/2025 5 5. service loads B 0 0 0 0 1 Internal Member Forces and Moments Member Axial Force (Min/Max) Shear Force Y (Min/Max) Shear Force Z (Min/Max) Torsion (Min/Max) Bending Moment Y (Min/Max) Bending Moment Z (Min/Max) 1 -0.006 / 0.010 -0.053 / 0.097 0.000 / 0.000 0.000 / 0.000 0.000 / 0.000 -0.081 / 0.042 2 -0.009 / 0.000 -0.087 / 0.000 0.000 / 0.000 0.000 / 0.000 0.000 / 0.000 -0.081 / 0.000 Member Displacement Span Check Member Length Max Relative Displacement Span Method 1 1 6.033 0.004 L/20133 2 1.508 0.006 L/3137 Member Stresses Member Axial Stress (Min/Max) Torsion Stress (Min/Max) Shear Stress Y (Min/Max) Shear Stress Z (Min/Max) Top Bending Moment Z (Min/Max) Bottom Bending Moment Z (Min/Max) 1 -0.001 / 0.001 0.000 / 0.000 -0.009 / 0.016 -0.000 / -0.000 -0.108 / 0.056 -0.056 / 0.108 2 -0.001 / 0.000 0.000 / 0.000 -0.014 / 0.000 0.000 / 0.000 -0.108 / 0.000 0.000 / 0.108 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 6 of 9 5313 W Henderson Pl2/5/2025 Array 2 Array Details Roof Framing Pre-Manufactured Truss (2x4) Non Standard DF No.2 Spacing 24.0" Beam Span 12.5' Roof Pitch 18° Solar Rails UR-40 Panel Quantity 15 Panel Array Area 324.53 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type OmniBase Tilt Mount 5/16” lag screw Shear Capacity NDS 190.0 lbs Pullout Capacity NDS 665.0 lbs Velocity Pressure Equation 26.10-1 (Kz=0.9, Kht=1, Kd=0.85, Ke=1.0) 15.61 psf GCP Zones 1/2e 2n/2r /3e 3r GCp Figure 30.3-(2A-5B)-1.93 -2.52 -3.0 Design Pressure Up [psf] Equation 29.4-7 ga=0.53 gE=1.0,-16.0 -21.0 -24.9 Factored Design Pressure Up [psf] ASD LC (.6D + .6W) -8.1 -11.0 -13.4 Exposed Design Pressure Up [psf] ga=0.53 gE=1.5, -24.0 -31.4 -37.4 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]82.6 60.4 49.7 Maximum Connection Spacing [in]317 232 191 Maximum Rail Span [in]80 80 77 Maximum Rail Cantilever [in]24 24 24 Design Connection Spacing [in] *Adjusted 72 72 72 Design Connection Spacing (exposed) [in]72 72 72 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 7 of 9 5313 W Henderson Pl2/5/2025 Design Ratio Member ID Axial Momentz Sheary Combined Slenderness Deflection Status 1 0.004 0.569 0.14 0.568 0.035 0.04 Pass 2 0.003 0.084 0.066 0.087 0.035 0.142 Pass Member Design Capacity (LRFD) Member ID FI b(ksi)FI t(ksi)FI v(ksi)FI c(ksi)FI cp(ksi)EI(ksi)Emin I(ksi) 1 2.681 1.49 0.311 2.683 0.939 1600.0 1041.216 2 2.681 1.49 0.311 2.683 0.939 1600.0 1041.216 Node Coordinates ID X Coordinate Y Coordinate 1 0.000 0.000 2 12.500 4.061 3 -1.500 -0.487 Members ID Node A Node B Section Node A Fixity Node B Fixity Length 1 1 2 1 FFFFFF FFFFFF 13.143 2 3 1 1 FFFFFF FFFFFF 1.577 Supports ID Node ID Restraint Code 1 2 RFFRRR 2 1 FFFFFR Materials ID Name Young's Modulus Density Poisson's Ratio 1 NDS - Table 4A - DOUGLAS FIR-LARCH - No.2- 2in & wider 1600.000 33.308 0.400 Sections ID Name Depth Width Shear Area Z Shear Area Y Torsion Radius 1 1.5 x 3.5 4.000 1.500 5.000 5.000 1.463 ID Centroid Y Centroid Z Area Y-Axis Mol Z-Axis Mol Torsion Constant 1 0.750 2.000 6.000 1.125 8.000 3.437 Point Loads ID Load Group Member Position %Y Magnitude 1 Solar-Snow 1 5.333%0.000 2 Solar 1 5.333%-0.033 3 Solar-Snow 1 52.936%0.000 4 Solar 1 52.936%-0.033 Member Distributed Loads ID Load Group Start Position End Position Member Y Magnitude 1 Dead Load 0.000%100.000%2 -0.013 2 Dead Load 0.000%100.000%1 -0.013 3 Roof Live Load 0.000%77.778%2 -0.032 4 Roof Live Load 92.539%100.000%1 -0.032 5 Snow Load 0.000%77.778%2 0.000 6 Snow Load 92.539%100.000%1 0.000 Load Combinations ID Name Dead Load Factor Snow Load Factor Solar Factor Solar-Snow Factor Roof Live Load Factor 1 1. 1.4D 1.4 0 1.4 0 0 2 3. 1.2D + 1.6Lr 1.2 0 1.2 0 1.6 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 8 of 9 5313 W Henderson Pl2/5/2025 3 3. 1.2D + 1.6S 1.2 1.6 1.2 1.6 0 4 4. service loads A 0 1 0 1 0 5 5. service loads B 0 0 0 0 1 Internal Member Forces and Moments Member Axial Force (Min/Max) Shear Force Y (Min/Max) Shear Force Z (Min/Max) Torsion (Min/Max) Bending Moment Y (Min/Max) Bending Moment Z (Min/Max) 1 -0.043 / 0.056 -0.134 / 0.174 0.000 / 0.000 0.000 / 0.000 0.000 / 0.000 -0.021 / 0.508 2 -0.027 / 0.000 -0.082 / 0.000 0.000 / 0.000 0.000 / 0.000 0.000 / 0.000 -0.075 / 0.000 Member Displacement Span Check Member Length Max Relative Displacement Span Method 1 1 13.143 0.035 L/4506 2 1.577 0.030 L/633 Member Stresses Member Axial Stress (Min/Max) Torsion Stress (Min/Max) Shear Stress Y (Min/Max) Shear Stress Z (Min/Max) Top Bending Moment Z (Min/Max) Bottom Bending Moment Z (Min/Max) 1 -0.007 / 0.009 0.000 / 0.000 -0.034 / 0.044 -0.000 / -0.000 -0.062 / 1.525 -1.525 / 0.062 2 -0.004 / 0.000 0.000 / 0.000 -0.021 / 0.000 -0.000 / -0.000 -0.226 / 0.000 0.000 / 0.226 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 9 of 9 5313 W Henderson Pl2/5/2025 City of Santa Ana, SIGNATURE:___________________ DATE:__________ 717 17th Street, Ste. 200 | Denver, CO 80202  I, Maria Valdez , grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar on my residence located at 5313 w henderson pl , SANTA ANA, CA, 92704. Docusign Envelope ID: 8D9C8E98-4991-4B64-8953-FA7B4C1C80F2 11/4/2024 5313 W Henderson Pl2/5/2025 Certificate Of Completion Envelope Id: 8D9C8E9849914B648953FA7B4C1C80F2 Status: Completed Subject: Complete with Docusign: 109R-313VALA.unsignedauthorizationdoc.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Stephanie Phillips AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 stephanie.phillips@sunrun.com IP Address: 12.133.93.10 Record Tracking Status: Original 11/4/2024 1:03:11 PM Holder: Stephanie Phillips stephanie.phillips@sunrun.com Location: DocuSign Signer Events Signature Timestamp Maria Valadez juanitapham2@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 71.136.238.250 Signed using mobile Sent: 11/4/2024 1:04:34 PM Viewed: 11/4/2024 6:48:59 PM Signed: 11/4/2024 6:49:04 PM Electronic Record and Signature Disclosure: Accepted: 11/4/2024 6:48:59 PM ID: 5ac9e216-7206-435a-80aa-52ee366fcead In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 11/4/2024 1:04:34 PM Certified Delivered Security Checked 11/4/2024 6:48:59 PM Signing Complete Security Checked 11/4/2024 6:49:04 PM Completed Security Checked 11/4/2024 6:49:04 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure 5313 W Henderson Pl2/5/2025 CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Maria Valadez 5313 W Henderson Pl2/5/2025 How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X 5313 W Henderson Pl2/5/2025 Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute 5313 W Henderson Pl2/5/2025 the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. 5313 W Henderson Pl2/5/2025 5313 W Henderson Pl2/5/2025 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST caitlyn hernandez 3854005019 oc_permits@sunrun.com 11.20.24 5313 W Henderson Pl2/5/2025