Loading...
HomeMy WebLinkAbout5313 W Henderson Pl - 101121650 & 20184540 - PlanPAGE REV: C2 3/11/2025 MARIA VALADEZ 5313 W HENDERSON PL, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 GILBERT CORREIA, C10, C46 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX SURGE PROTECTOR TO BE INSTALLED PER MANUFACTURER AND PANEL BOARD SPECS. PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-3.2 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CALCS PV-4.2 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE LTD: LR5-54HABB-400M WITH STANDOFF TO FRAMING: SNR-DC-01249 [FLAT, FLUSH MOUNT ( ROLLED COMP/ MEMBRANE/ FOAM) 1 LAG OMNIBASE]; ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING, SNR-DC-00339 1707000-XX-Y, (1) EXPANSION 1807000-XX-Y (MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE PANEL WITH 50 AMP MAIN BREAKER TO BE REPLACED WITH NEW 125 AMP MAIN PANEL WITH 125 AMP MAIN BREAKER AND 225 AMP BUSBAR. MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). MODULES, ARE CLASS A FIRE RATED. CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) D WARNING: POWER SOURCE OUTPUT CONNECTION -- DO NOT RELOCATE THIS OVERCURRENT DEVICE. Revision to 20184540 (issued on 2/4/25) Rev 1 #20185409 APPROVALS: ELECT - M. Smith 5313 W Henderson Pl3/27/2025 PAGE REV: C2 3/11/2025 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 GILBERT CORREIA, C10, C46 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184PLPLPLPLPLPLPLPLPLPL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 2538 SQFT.  TOTAL PV ARRAY AREA: 441.4 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 = 17.4% ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN  ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM  EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER  SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE  BASED ON LARGE/SCALE FIRE TESTING. POWERWALL ENERGY  STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANEL ELECTRIC VEHICLE  SUPPLY EQUPMENTEV MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE  INTERIOR EQUIPMENT  SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMA GROUNDING  ELECTRODE ENERGY STORAGE  SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE  1 COMMUNICATION  WIRESAM MD MICROGRID  INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEMPV LOAD CENTERLC LEGEND  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN RAIL STANDOFFS &  FOOTINGS SOLAR  MODULES SITE PLAN - SCALE = 0'-0 3/64" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) SE MP INV W HENDERSON PL MD ROOF PATHWAYS (3' TYP) AC (E) FENCE  (E) GATE (TYP.) EXTERNAL RAPID SHUTDOWN SWITCH RSD A A A A A A A A B B B B B B B C C C C C C (E) DETACHED  STRUCTURE (E) PATIO ARRAY  PITCH PV AREA  (SQFT) AR-01 6° 126.1 AR-02 18° 315.3179° TRUE  AZIM MAG  AZIM 167°179° 167° NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE  INSTALLED MODULE PER NEC 690.12 RSD D I V I LREGISTERED PR O F ESSIONAL E N G I NEERS T ATE OF C A L IFORNIAROBER T SMYT H EC56136 EXP. 12/31/26 5313 W Henderson Pl3/27/2025 PAGE REV: C2 3/11/2025 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 GILBERT CORREIA, C10, C46 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 NEW125A MAIN BREAKER END FED NEW 125A MAIN PANEL 225A  BUS J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 1 OF 7 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 2 OF 8 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES 1 1 2 POINT OF INTERCONNECTION:705.12(B)(3)(2),  METER NUMBER: 222013-570957 REPLACE EXISTING 50  MAIN PANEL WITH NEW 125A  MAIN PANEL 125A MAIN BREAKER  AND 225A BUS BAR EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED = 60A USED FOR INTERCONNECTION CALCULATIONS TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 FACILITY  GROUND (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 1 LONGI GREEN  ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M STRING 1 OF 6 MODULES 2  MODULE LEVEL RAPID SHUTDOWN DEVICES (N) IMO PE69-3020,  DISCONNECT  SWITCH, 3P, 16A UL 9540  FACTORY WIRING  ASSEMBLY (1 ) TESLA POWERWALL 3 EXPANSION PACK 1807000-XX-Y 60A M TESLA  BACKUP  SWITCH CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG  (PV WIRE)N/A 6 AWG (BARE)Open Air 2 Inverter Input (6) 10 AWG  THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4" EMT 3 Inverter Output (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 3/4" EMT PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY  TECHNOLOGY CO LTD:  LR5-54HABB-400M 400 W OPEN CIRCUIT VOLTAGE 37.05 V MAX POWER VOLTAGE 30.94 V SHORT CIRCUIT CURRENT 13.72 A GENERAL NOTES: GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND IF THE RELOCATED LOADS EXTEND MORE  THAN 6 FEET, AFCI PROTECTION APPLIES  PER 2019 CEC 210.12 ANY MULTIWIRE BRANCH CIRCUITS  RELOCATED ARE TO BE IDENTIFIED,  GROUPED, AND EQUIPPED WITH A  2-POLE OCPD BREAKER PER CEC  210.4(B,D). D D 5313 W Henderson Pl3/27/2025 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL DEMAND  LOAD 1 20A-1P KITCHEN 1500 VA 2 20A-1P KITCHEN 1500 VA 3 20A-2P OTHER 3840 VA 5 15A-1P ROOMS 1500 VA 6 15A-1P ROOMS 1500 VA 7 30A-2P DRYER 5760 VA PV-4.1 ELECTRICAL CALCS ELECTRICAL CALCS SYSTEM INFORMATION 8.4 KW DC PHOTOVOLTAIC SYSTEM      (21) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y ALLOWABLE BACKFEED ALLOWABLE BACKFEED = (MAIN PANEL RATING) X 1.2 - (MAIN BREAKER RATING) =  225A X 1.2 - 125A = 145A 60A ≤ 145A → INTERCONNECTION MEETS 705.12(B)(3)(2) REQUIREMENTS. INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=  13.72 A X 1.25 X 1.25= 21.44A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 0.8 X 40A = 29.12A TERMINAL RATING[110.14(C)] = 10 AWG, 75°C RATED = 35A 29.12A < 35A    TERMINAL RATING GOVERNS CONDUCTOR SIZING.          21.44A < 29.12A   10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =          0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] =         6 AWG,75°C RATED = 65A 65A < 68.25A   TERMINAL RATING GOVERNS CONDUCTOR SIZING.         60A < 65A   6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X  (# MODULES / STRING) = {[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 8 = 317 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 13.72 A X 3 = 51.45A PAGE REV: C2 3/11/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 D 5313 W Henderson Pl3/27/2025 LIGHTS /RECEPTABLES ROOMS LIGHTS /RECEPTABLES PANEL SCHEDULE PANEL SCHEDULE PV-4.2 KITCHEN PAGE REV: C2 3/11/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 MAIN BREAKER 125 NEW 225/125A   MAIN PANEL 60PV + ESS  BREAKER3015152020DRYER20OTHER D 5313 W Henderson Pl3/27/2025 PAGE REV: C2 3/11/2025 MARIA VALADEZ 5313 W HENDERSON PL, SANTA  ANA, CA, 92704 PROJECT NUMBER:   109R-313VALA SHEET DESIGNER: CHIPPY PRINCE CUSTOMER RESIDENCE: TEL. (714) 493-3532 APN: 108-392-16 (415) 580-6920 ex3 Template_version_v5_2024 02 28 GILBERT CORREIA, C10, C46 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 SIGNAGE PV-5.0 #ESTAMP ENERGY STORAGE SYSTEM  DISCONNECT LABEL LOCATION: ENERGY STORAGE SYSTEM DISCONNECT PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022  ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY  SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING  EFFECTIVE WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR  WIRING METHOD AND SHALL NOT BE HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE  ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT  SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2)CAUTION  5313 W HENDERSON PL, SANTA ANA, CA, 92704 SOLAR PANELS ON ROOF PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) AC DISCONNECT INVERTER & ENERGY STORAGE  (EXT) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT MAXIMUM SYSTEM VOLTAGE: LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 EXPANSION ENERGY  STORAGE (EXT) SERVICE ENTRANCE WITH TESLA  BACKUP SWITCH RAPID SHUTDOWN SWITCH D 5313 W Henderson Pl3/27/2025