HomeMy WebLinkAbout3000 3%4 W MacArthur Blvd WCC01 - Plan1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 GN-1 1GENERAL NOTES & SPECIFICATIONS2ABBREVIATIONS & SYMBOLS 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 GN-2 3 FIRE DEPARTMENT 2 BATTERY NOTES BATTERY SPECIFICATIONS 1 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 T-1 UNDERGROUND SOUTHERN CALIFORNIA SERVICE ALERT OF 800-227-2600 SITE INFORMATION VICINITY MAP LOCAL MAP LOCATION MAPS PROJECT TEAM DRIVING DIRECTIONS CODE COMPLIANCEDO NOT SCALE DRAWINGS PROJECT: 5G NR 1SR CBAND SITE TYPE: ROOFTOP (INDOOR) SITE ADDRESS: 3000 WEST MCARTHUR BLVD. SANTA ANA, CA 92704 FA NUMBER: 10087079 USID NUMBER: 12478 PACE NUMBER: WSLOS0025041/ WSLOS0025486/ WSLOS0025691/ WSLOS0067306 SITE NUMBER: CLU3418/CLL03418 SITE NAME: FAIRVIEW / MACARTHUR PROJECT DESCRIPTION DRAWING INDEX · · · · · · · · · · · · · · · ·. · · · · · · · CONSTRUCTION DRAWINGS SI SI Bldg #101124327 APPROVALS: PLNG - F. DAlessandro BLDG - W. Lee PUBLIC WORKS - Y. Soto 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-1 1SITE PLAN 15'30'60'1"=30'-0" SCALE: SECTOR 'B' 230° SECTOR 'C' 5° W L A K E C E N T E R D R I V E W MA C A R T H U R B L V D . SECTOR 'A' 100° SECTOR 'C' 350° W A L P I N E S T R E E T 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-2 1ROOF PLAN 3/32"=1'-0" SCALE: 2(E) EQUIPMENT PLAN 3/8"=1'-0" SCALE: 3(N) EQUIPMENT PLAN 3/8"=1'-0" SCALE: SECTOR 'B' 230° SECTOR 'C' 5° SECTOR 'A' 100° SECTOR 'C' 350° 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-3 1(E) ANTENNA PLAN 3/8"=1'-0" SCALE: 3ANTENNA/RRUS SCHEDULE 2(N) ANTENNA PLAN 3/8"=1'-0" SCALE: SECTOR 'B' 230° SECTOR 'C' 5° SECTOR 'A' 100° SECTOR 'B' 230° SECTOR 'C' 5° SECTOR 'A' 100° SECTOR 'C' 350° 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-4 2(N) SOUTHEAST ELEVATION 3/32"=1'-0" SCALE: 1(E) SOUTHEAST ELEVATION 3/32"=1'-0" SCALE: 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-5 2(N) SOUTHWEST ELEVATION 3/32"=1'-0" SCALE: 1(E) SOUTHWEST ELEVATION 3/32"=1'-0" SCALE: 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-6 2ANTENNA SPECIFICATIONS 1ANTENNA SPECIFICATIONS ERICSSON 4RRUS SPECIFICATIONS 3RRUS SPECIFICATIONS 5RRUS SPECIFICATIONS MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT MARATHON M12V185FT 6-48V BATTERY RACK SPECIFICATIONS 7STUCCO FINISH BY "STO" 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 A-7 3WALL MOUNT (SITEPRO#1 WWM01) 4RRUS MOUNT 5RRU BRACKET @ PIPE & RRUS MOUNTING BRACKET A DETAIL A 6" 6" 8" 1ANTENNA MOUNT @ SECTOR 'A' 2ANTENNA MOUNT @ SECTOR 'B' & 'C' STRUCTURAL NOTES NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THESE STANDARD STRUCTURAL NOTES.DETAILS NOTED AS "TYPICAL"SHALL BE USED WHENEVER APPLICABLE. REFER TO SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE NOTES OR DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK, AND THE ENGINEER/ARCHITECT SHALL BE IMMEDIATELY NOTIFIED, IN WRITING, OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL DRAWINGS. ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF, AND RESOLVED WITH, THE ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. WHERE A CONSTRUCTION DETAIL IS NOT SPECIFICALLY SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE EXCAVATED, BEFORE BEGINNING EXCAVATION. NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN OR THRU SLABS, BEAMS, OR WALLS, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. EXCEPT AS INDICATED ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. RETAIN A CALIFORNIA REGISTERED CIVIL ENGINEER TO DESIGN ALL TEMPORARY BRACING, SHORING, AND SUPPORT REQUIRED DURING CONSTRUCTION. INCLUDE ENGINEERING FEES, ENGINEERING DESIGN TIME AND BUILDING DEPARTMENT APPROVAL TIME IN THE COST OF PROPOSED MATERIAL ALTERNATES. CONTACT ENGINEER FOR FEE AMOUNT. SUBMIT MATERIAL ALTERNATE FOR REVIEW BEFORE CONSTRUCTION. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2019 CBC. 1. 2. 3. 4. 5. 6. 8. 9. 10. 7. GENERAL 11. IF STRUCTURAL OBSERVATIONS ARE REQUIRED, PROVIDE 72 HOURS NOTICE PRIOR TO OBSERVATION. STRUCTURAL STEEL ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE CBC CHAPTER 22, FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL BUILDINGS. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. OTHER ROLLED SHAPES AND PLATES SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE. HSS SHALL CONFORM TO ASTM A500, GRADE-B. PIPES SHALL CONFORM TO ASTM A53, GRADE-B. IDENTIFICATION PROCEDURES SHALL CONFORM TO ASTM A6. MACHINE BOLTS SHALL BE GRADE-A CONFORMING TO ASTM A307. ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. NUTS FOR MACHINE BOLTS AND ANCHOR BOLTS SHALL CONFORM TO ASTM A563, HEX GRADE-A. THREADED RODS SHALL CONFORM TO ASTM A36. THREADED AND NUTTED ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. ROUND WASHERS SHALL CONFORM TO ASTM F436. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325. NUTS FOR HEIGHT STRENGTH BOLTS SHALL BE HEAVY HEX, GRADE-C, CONFORMING TO ASTM A563. INSTALLATION OF HIGH STRENGTH BOLTS SHALL BE INSPECTED AS REQUIRED BY "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A 490 BOLTS" (JUNE 2004). ALL BOLT HOLES SHALL BE 1/16" LARGER THAN THE BOLT, UNLESS NOTED OTHERWISE. HEADED STUDS EMBEDDED IN CONCRETE SHALL CONFORM TO ASTM A108. NON-SHRINK GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 7000 SPI PER ASTM C109. NON-SHRINK GROUT SHALL BE INSTALLED IMMEDIATELY AFTER COLUMN IS PLUMBED. CONTRACTOR SHALL NOT LOAD COLUMN ANCHOR BOLTS BEFORE PLACEMENT OF NON-SHRINK GROUT WITHOUT TAKING MEASURES TO PREVENT BUCKLING OF ANCHOR BOLTS UNDER CONSTRUCTION LOAD. WELDING SHALL CONFORM TO THE LATEST EDITION OF AWS D1.1 AND SHALL USE EITHER THE SHIELDED OR FLUX CORE METHODS. ELECTRODES USED SHALL BE E70XX, E71-T8 OR E70-T6. WELDERS SHALL BE CERTIFIED. WELDS IDENTIFIED AS REQUIRING CONTINUOUS OR PERIODIC SPECIAL INSPECTION NEED NOT HAVE CONTINUOUS SPECIAL INSPECTION WHEN THE WELDING IS DONE IN AN APPROVED FABRICATOR'S SHOP. HOWEVER, THE APPROVED FABRICATOR MUST SUBMIT A CERTIFICATE OF COMPLIANCE IN ACCORDANCE WITH CBC SECTION 1704.2. ALL FULL PENETRATION GROOVE WELDS FOR MOMENT FRAME MEMBERS SHALL BE ULTRASONICALLY INSPECTED BY AN APPROVED TESTING AGENCY AND SHALL CONFORM TO THE LATEST EDITION OF AWS D1.1, SECTION 5 & 6. ALL STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED AND ALL FIELD WELDS FOR SUCH MEMBERS SHALL BE TOUCHED UP WITH GALVALOID. STEEL FABRICATOR TO VERIFY ALL DIMENSIONS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. STEEL FABRICATOR TO COORDINATE WITH MECHANICAL SUBCONTRACTOR FOR THE SIZE, LOCATION, AND DIMENSIONS OF MECHANICAL UNITS AND OPENINGS. ALL FABRICATION SHALL BE DONE IN A SHOP OF AN APPROVED FABRICATOR. STRUCTURAL STEEL SHOP DRAWINGS SHALL BE SUBMITTED TO AND REVIEWED BY THE ENGINEER BEFORE FABRICATION. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. SPECIAL INSPECTION REQUIRED SPECIAL INSPECTION 1.SPECIAL INSPECTION SHALL MEET THE REQUIREMENTS OF CBC SECTION 1704. 2.SPECIAL INSPECTORS SHALL: A.BE UNDER THE SUPERVISION OF A CALIFORNIA REGISTERED CIVIL ENGINEER. B.OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE APPROVED DRAWINGS AND SPECIFICATIONS. C.FURNISH INSPECTION REPORTS TO THE ENGINEER AND BUILDING DEPARTMENT. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN IF NOT CORRECTED, TO THE ENGINEER AND BUILDING DEPARTMENT. D.SUBMIT TO THE ENGINEER AND BUILDING DEPARTMENT A FINAL REPORT, SIGNED BY A CALIFORNIA REGISTERED CIVIL ENGINEER, STATING THAT THE WORK WAS IN CONFORMANCE WITH THE APPROVED DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CBC. 3.INSPECTION NOTES: A.CONSTRUCTION INSPECTIONS LISTED ARE IN ADDITION TO THE CALLED INSPECTIONS REQUIRED BY CBC SECTION 109,APPENDIX CHAPTER 1. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY A BUILDING OFFICIAL. SPECIALLY INSPECTED WORK WHICH IS INSTALLED OR COVERED WITHOUT APPROVAL OF THE BUILDING OFFICIAL IS SUBJECT TO REMOVAL OR EXPOSURE. B.CONTINUOUS INSPECTION IS ALWAYS REQUIRED DURING PERFORMANCE OF THE WORK UNLESS SPECIFICALLY NOTED. C.SPECIAL INSPECTORS MUST BE CERTIFIED BY THE BUILDING DEPARTMENT TO PERFORM THE TYPES OF INSPECTIONS SPECIFIED. D.IT IS THE RESPONSIBILITY OF THE OWNER TO INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT LEAST ONE WORKING DAY BEFORE PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION. ALL WORK PERFORMED WITHOUT REQUIRED SPECIAL INSPECTION IS SUBJECT TO REMOVAL. 1.ANCHORS, ANCHOR BOLTS, & DOWELS A.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS (AND TESTING) OF EPOXIED DOWELS IN CONCRETE AT (HOLDOWNS) (EXISTING FOOTINGS) (CONCRETE REPAIRS). B.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS OF WEDGE AND SLEEVE ANCHORS (WHERE INDICATED). SCHED.SCHEDULEHDHOLD DOWNBOTTOMBTM. DITTO (REPEAT) EXST. (E) EXP. EXT. EXPANSION EXTERIOR EXISTING DP (D) EL. EQ. ENG. E.N. EMBD. ELEV. ELEC. EQPT. DWG. DWL. EA. E.J. E.F. ELEVATION ENGINEER EDGE NAIL/SCREWS EMBED(MENT) ELECTRICAL EQUIPMENT EQUAL ELEVATOR DEEP (DEPTH) DRAWING(S) EXPANSION JOINT EACH FACE DOWEL(S) EACHEACH EACH CONSTRUCTIONCONST. DIA. ( ) DIAPH. DEPT. D.F. DIAG. DIM. DN. do CONT. CTR. C.Y. d DBL. CTSK. DEPARTMENT DOUGLAS FIR DIAPHRAGM DIMENSION Ø DIAMETER DIAGONAL DOWN CONTINUOUS CENTER(ED) CUBIC YARD PENNY(NAILS) COUNTERSINK DOUBLE CAMB.(C) CONN. CL. OR C.J. CLG. CLR. CMU. COL. CONC. BTWN. CANT. C.F. C.G. C.I.P. CONSTRUCTION JOINT CENTER LINE CONCRETE CONNECTION CONC. MASONRY UNIT CEILING CLEAR COLUMN L(C) CAMBER(ED) CANTILEVERED CAST IN PLACE CUBIC FEET (FOOT) CENTER OF GRAVITY BETWEEN VERIFY IN FIELD VERTICAL UNLESS NOTED OTHERWISE UNIFORM BUILDING CODE WELDED WIRE FABRIC WELDED STUD(S) WEAKENED PLANE JOINT WORK POINT WIDE (WIDTH) DOUBLE EXTRA STRONG EXTRA STRONG OPEN WEB JOISTS OUTSIDE DIAMETER ON CENTER ORIENTATE(ION) OPENING OPPOSITE HAND OUTSIDE FACE O.C. ORNT. OPNG. O.H. O.F. O.D. XX-STG YD YARD NON-SHRINK GROUT MTL.METAL NOT TO SCALE NEAR SIDE NUMBER NEW N.T.S. N.S.G. N.S. NO. (#) (N) MACHINE BOLT MECHANICAL MEZZANINE MANUFACTURER MISCELLANEOUS MINI-LAM-BM. MINIMUM M.B. MECH. MEZZ. MFR. MISC. MLB MIN. WOODWD. X-STG WWF WT W.S. WPJ W.P. WEIGHT VIF VERT. U.N.O. UBC w/ (W) WITH SQUARE SIMILAR SELECT STRUCTURAL SPECIFICATION(S) SPACE(S)(ING) SKEW(ED) SHEATHING STAGGER(ED) SYMMETRICAL SUSPENDED(TION) STRUCTURAL STIRRUP(S) STIFFENER(S) TOP AND BOTTOM TOP OF WALL TOP OF SHEATHING TOE NAIL TEMPORARY THREADED THICK(NESS) TONGUE AND GROOVE TEMPERATURE TYPICAL TOP OF STEEL TRANSVERSE STANDARD SYMM.K KIPS (1000) LINEAR FEET (FOOT) LGTH LENGTH LONG LEG HORIZ. LONG LEG VERT. LIGHT WEIGHT MASONRY MATERIAL MAXIMUM LLH LLV LT.WT. MAS. MAT'L. MAX. LATERAL POUNDS LAG BOLTS LEDGER LONG(ITUDINAL) LAT. LB (#) L.B. LDGR L.F. LG. TMPRY. TRANSV. T.O.W. T.O.S. T.N. TYP. T.S. T & B T & G THRD. THK. TEMP. (T)TOP INCH(ES) INTERIOR JOIST JOINT INSIDE FACE IN. (") INT. JST. JT. I.F. HEADER HANGER HORIZONTAL HIGH STRENGTH BOLTS HEIGHT INSIDE DIAMETER INVERT ELEVATION HDR. HGR. HORZ. (H) HSB HT. I.D. I.E. STRUC. SUSP. STL. STIR. STIFF. STGR. STD. STEEL SHT. SS SQ. SPEC. SPC. SKW. SIM. SHTG. SHEET STRUCTURAL ABBREVIATIONS APPROXIMATE(LY)APPRX. BNDRY. BLKG. BM. B.N. B.O.F. BRDG. BRG. ARCH. & OR @ B.F. BLDG. BLK. BEL. BLOCKING BOUNDARY BRIDGE(ING) BOUNDARY NAILING BOTTOM OF FOOTING BEAM BEARING ARCHITECT(TURAL) BRACED FRAME AND AT BUILDING BLOCK BELOW A.B. ABV. ADD'L ADJ. ALUM. ALT. ANCHOR BOLT ADDITIONAL ADJACENT ALUMINUM ALTERNATE ABOVE RIDGE BOARD PARALLEL PRECAST CONCRETE PERPENDICULAR PARALLEL STRAND LUMBER PLYWOOD POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED POSTTENSIONED (PRESTRESSED) QUANTITY REINFORCED CONCRETE PIPE REFERENCE REINFORCEMENT(ING) REQUIRED RIGID FRAME ROUGH OPENING P.S.F.F.O.C.FACE OF CONCRETE FACE OF MASONRY GLUED LAMINATED BEAM GYPSUM WALLBOARD GAUGE GALVANIZED GRADE BEAM GRADE GA. GALV. GB GLB GRD. GYPDB. FACE OF STUD FACE OF WALL FRAME(ING) FOOT (FEET) FOOTING FAR SIDE F.O.M. F.O.S. F.O.W. FRM. FT. (') FTG. F.S. RAD. (R) REQ'D. R.B. R.C.P. REF. REINF. R.F. R.O. P.S.I. P.T. P/T QTY. RADIUS FABRICATION FOUNDATION FINISH(ED) FLANGE FLOOR FIELD (FACE) NAIL FAB. FND. FIN. FLG. FLR. F.N. PAR. (//) P PERP. ( ) PL. ( ) P/C PSL PLY. L PLATE OWJ. E.S.EDGE SCREWS FIELD VERIFYF.V. 4. 5. 6. THE MAXIMUM THICKNESS APPROVED FOR THE USE IS 14" WITH THE EXCEPTION FIBREBOLTS WHICH ARE LIMITED TO 12" AND 5 8" DIAMETER BOLTS. PRODUCTS SHALL BE LABELED OR PACKAGE CLEARLY IDENTIFYING THE PRODUCT AS EXTREN 525 MANUFACTURED BY STRONGWELL COMPANY. 7. THE MAXIMUM ALLOWABLE TENSILE LOAD FOR 12" & 5 8" DIAMETER BOLTS SHALL BE 550 LBS., AND682 LBS. RESPECTIVELY, THE MAXIMUM ALLOWABLE SHEAR LOAD FOR THE 12" AND 5 8" DIAMETER BOLTS SHALL BE 861 LBS. AND 1052 LBS. RESPECTIVELY. 6 2. 1. PROPERTIES OF FRP: FU= 30,000 PSI FIBERGLASS REINFORCED PLASTIC IS A COMPOSITE CONSISTING OF A PLASTIC RESIN MATRIX REINFORCED BY EMBEDDED GLASS FIBERS. FIBERGLASS REINFORCED PLASTIC (FRP) 3.ANCHOR BOLTS SHALL BE 1/2"Ø FRP BOLTS UNLESS NOTED OTHERWISE. E= 2.6x10 PSI 8. 9.THE FIBERGLASS PRODUCT SHALL PROTECTED WITH AN MFG APPROVED UV INHIBITOR. THE DESIGN OF ALL FRP STRUCTURAL SHAPES, EXCLUDING BOLTS EXCEPT AS APPROVED HEREIN, SHALL BE IN ACCORDANCE WITH THE ASCE PRE-STANDARD FOR LOAD & RESISTANCE FACTOR DESIGN (LRFD) OF PULTRUDED FIBER REINFORCED POLYMER (FRP) STRUCTURES. ONLY FIBERGLASS NUTS SHALL BE USED WITH THE FIBREBOLTS, STEEL NUTS SHALL BE PROHIBITED. 10.ALL FRP MEMBERS SHALL BE IDENTIFIED WITH LARR #25536 AND FIBERGATE LABEL. DESIGN CRITERIA LATERAL LOADS: A) EARTHQUAKE DESIGN DATA: SEISMIC IMPORTANCE FACTOR...................................... OCCUPANCY CATEGORY................................................. MAPPED SPECTRAL RESPONSE ACCEL.....................Ss S1 SITE CLASS......................................................................... SPRECTRAL RESPONSE COEFF................................SDS SD1 SEISMIC DESIGN CATEGORY.......................................... B) WIND: BASIC WIND SPEED........................................................ SITE EXPOSURE.............................................................. I.......................................................................................... =1.25 =II =1.304 =0.468 =D =1.043 =N/A =D 101 MPH = D =1.25 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 S-1 George Gomez, P.E. C VI C 92845 EORGE GOME REGISTERED PROFESSIONALENGINEER STATE OF CAL IFORNIAIL ZG 9 7 6 5 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E ) W 1 2 x 1 9 (E) W18x40 (E) TAPERED STEEL BEAM (E) TAPERED STEEL BEAM (E) COL. TYP. (E) COL. TYP. (E) W18x40 (E) TAPERED STEEL BEAM 1ROOF PLAN2ROOF PLAN 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 S-2 3/32"=1'-0" SCALE: 1/4"=1'-0" SCALE: SECTOR 'B' 230° SECTOR 'C' 5° SECTOR 'A' 100° SECTOR 'C' 350° George Gomez, P.E. C VI C 92845 EORGE GOME REGISTERED PROFESSIONALENGINEER STATE OF CAL IFORNIAIL ZG 1ANTENNA FRP SCREEN @ SECTOR 'A' 3ANTENNA FRP SCREEN @ SECTORS 'B' & 'C' 4ANTENNA FRP SCREEN PLAN VIEW @ SECTORS 'A','B' & 'C' 7ANTENNA FRP SCREEN ELEVATION VIEW @ SECTORS 'A','B' & 'C' 8DETAIL11ANTENNA MOUNT ANCHORAGE @ SECTOR 'A', 'B' & 'C' 9DETAIL12DETAIL EQ . EQ . 5' - 6 " M A X . H E I G H T FR P S C R E E N W A L L 6" MI N . 6" MI N . 6" MI N . 6" MI N . STEEL L4x4x14 FRP ANGLE BRACE L4x4x14 TYP. FRP ANGLE L4x4x14 TYP. 5 8"Ø FRP THROUGH BOLTS TYP. 5 8"Ø FRP THROUGH BOLTS TYP. 5 8" Ø A307 THROUGH BOLT 5 8" Ø A307 THROUGH BOLT 5 8" Ø A307 THROUGH BOLT 5 8"Ø FRP THROUGH BOLTS TYP. 5 8" Ø A307 THROUGH BOLT 5 8" Ø A307 THROUGH BOLT EQ. 12'-0" MAX. FRP SCREEN WALL EQ.EQ.EQ. 5 8" Ø A307 THROUGH BOLT TYP. STEEL L4x4x14 TYP. (E) 71 4" THICK CONCRETE WALL (FIELD VERIFY) FRP SCREEN FRP SCREEN FRP ANGLE L4x4x1 4" TYP. 5 8"Ø FRP THROUGH BOLTS TYP. FRP ANGLE BRACE L4x4x14 TYP. 5 8"Ø FRP THROUGH BOLTS TYP. EQ. 12'-0" MAX. HEIGHT FRP SCREEN WALL EQ.EQ.EQ. FRP SCREEN FRP ANGLE L4x4x14(TYP.) 5 8"Ø FRP THROUGH BOLTS TYP. 5 8"Ø FRP THROUGH BOLTS TYP. 2'-6" MAX. EQ . EQ . 5' - 6 " M A X . H E I G H T FR P S C R E E N W A L L STEEL L4x4x14 FRP ANGLE BRACE L4x4x14 TYP. FRP ANGLE L4x4x14 TYP. 5 8"Ø FRP THROUGH BOLTS TYP. 5 8"Ø FRP THROUGH BOLTS TYP. 5 8"Ø FRP THROUGH BOLTS TYP. FRP SCREEN 2'-6" MAX. 2' - 6 " MA X . FRP SCREEN 5' - 6 " M A X . H E I G H T FR P S C R E E N W A L L FRP ANGLE BRACE L4x4x14 TYP. FRP ANGLE L4x4x1 4 (TYP.) 1,3 S4.0 4 S-3 (N) BATTERY CABINET 3276 LBS MAX.(4) - 5 8" Ø HILTI KWIK BOLT (KB-TZ2) EXPANSION ANCHORS w/ 3- 14 " MIN. EMBED PER ESR-4266. (2) ANCHORS EACH SIDE OF CABINET MINIMUM, TO ATTACH UNIT TO (E) CONCRETE DECK (SPECIAL INSPECTION REQUIRED). EXISTING METAL DECKING w/ 6" CONC. TOPPING (FIELD VERIFY) 4 S-3 4 S-3 (E) TILT UP CONCRETE WALL (N) FRP SCREEN PER DETAILS ON THIS SHEET SITEPRO #1 WWM01 w/ (4) 5 8" Ø HILTI KWIK BOLT (KB-TZ2) EXPANSION ANCHORS w/ 314" NOMINAL EMBED PER ESR-4266. PANEL ANTENNA PER ARCH. X X EMBED EMBED X 5 8" Ø SS HILTI KWIK BOLT TZ 314" NOMINAL EMBED (ICC ESR#4266) TO CONC. WALL TYP. 5 8" Ø SS HILTI KWIK BOLT TZ 314" NOMINAL EMBED (ICC ESR#4266) TO CONC. WALL TYP. 5 8" Ø SS HILTI KWIK BOLT TZ 314" NOMINAL EMBED (ICC ESR#4266) TO CONC. WALL TYP. (E) 714" THICK CONCRETE WALL (FIELD VERIFY) (E) 714" THICK CONCRETE WALL (FIELD VERIFY) SITEPRO #1 WWM01 w/ (4) 5 8" Ø HILTI KWIK BOLT (KB-TZ2) EXPANSION ANCHORS w/ 31 4" NOMINAL EMBED PER ESR-4266. 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 S-3 George Gomez, P.E. C VI C 92845 EORGE GOME REGISTERED PROFESSIONALENGINEER STATE OF CAL IFORNIAIL ZG 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 10 CHURCH CIRCLE ANNAPOLIS, MD 21401 4430 E. MIRALOMA AVE. SUITE D ANAHEIM, CALIFORNIA 92807 E-1 5EQUIPMENT ELECTRICAL/GROUNDING PLAN 6ANTENNA GROUNDING PLAN 3GROUNDING NOTES 1GROUND BAR 2INSTL OF GRND CONDUCTOR4INTERIOR TWO HOLE LUG 3/8"=1'-0" SCALE: 1/2"=1'-0" SCALE: YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 4430 E. Miraloma Ave. Suite D Anaheim, California 92807 CLU3418/CLL03418 FAIRVIEW / MACARTHUR 5G NR 1SR CBAND 3000 West Macarthur Santa Ana, CA 92704 Prepared for STRUCTURAL CALCULATIONS Structural Analysis By June 9, 2025 1452 EDINGER AVE. TUSTIN, CALIFORNIA 92780 George Gomez, P.E. C VI C 92845 EORGE GOME REGISTERED PROFESSIONALENGINEER STATE OF CAL IFORNIAIL ZG Design Criteria I. Applicable Codes -California Building Code (CBC) 2022 -ASCE 7-16 -TIA 222-H -AISC 360-16 -AISC 341-16 -ACI 318-19 II. Scope of Work This project consists of replacing existing antennas with new antennas. All antennas will be mounted onto new antenna mounts attached to the existing concrete walls of the building. New frp screen enclosures will be installed around the new antennas. Additionally, we will be replacing an existing equipment cabinet with a new cabinet in the equipment room. Equipment Cabinet: 1. NEQ. 20326 48V NETSURE VRLA BATTERY RACK Antenna Equipment (see architectural plans for quantities and locations): 1. KATHREIN 800-10964K 2. ERICSSON AIR6419 B77D 3. COMMSCOPE NNH4-65A-R6H4 4. RRUS 32 B30 5. RRUS 4449 B5/B12 6. RRUS 4890 B25/B66 7. RRUS 4494 B14/B29 8. COMMSCOPE CBC61923T-DS-43 III. Structural Assessment New Battery Cabinet Anchorage to slab 61.0% PASS Antenna Mount Stress Level with Proposed Equipment 10.0% PASS FRP Screens 29.1% PASS IV. Provisions of Analysis & Disclaimer Our structural calculations are completed assuming all information provided to us is accurate and applicable to this site. For the purposes of calculations, we assume an overall structure condition of “like new” and all members, connections, anchors, and surfaces to be free of corrosion and/or structural defects. The structure owner and/or contractor shall verify the structure’s condition prior to installation of any proposed equipment. If actual conditions differ from those described in this report, the Engineer of record should be notified immediately to complete a revised evaluation. AT&T CLU3418 1 of 39 ASCE Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Latitude:33.69971 Risk Category:III Longitude:-117.91083 Soil Class:D - Default (see Section 11.4.3) Elevation:37.48642610770208 ft (NAVD 88) Wind Results: Wind Speed 101 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1C and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Jun 09 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 3% probability of exceedance in 50 years (annual exceedance probability = 0.000588, MRI = 1,700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Mon Jun 09 2025 AT&T CLU3418 2 of 39 SS : 1.304 S1 : 0.468 F a : 1.2 F v : N/A SMS : 1.565 SM1 : N/A SDS : 1.043 SD1 : N/A T L : 8 PGA : 0.56 PGA M : 0.672 F PGA : 1.2 Ie : 1.25 C v : 1.361 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Mon Jun 09 2025 Page 2 of 3https://ascehazardtool.org/Mon Jun 09 2025 AT&T CLU3418 3 of 39 AT&T CLU3418 4 of 39 project by CASA location date 6/9/2025 client job no. 25-181 (Based on USGS and ASCE 7 Standard)Wind - ASCE 7 Sec 29.5.1 Sds=1.043 g Fh = qh*GCr*Af Sd1=N/A g kz = 0.85 V = 101 MPH Unit Series: qh = 18.87 psf Unit height=84 inch GCr = 1.9 Unit width=22.7 inch Af = 16.0 sf Unit length=27.5 inch Fh = 575 lbs Unit dead load(Wp)=3276 lbs less than Fp*Omega Unit live load=0 lbs SEISMIC - ASCE 7 Sec 13.3.1 ( ASCE EQ. 13.3-1) Rp=2.5 ( ASCE table 13.6-1) ap=1 ( ASCE table 13.6-1) Ip=1.0 ( ASCE sec 13.1.3) Wp= 3276 lbs 1+2(z/h) = 2.14 Fp= 1171 lbs omega = 2 Fp-max = 1.6*Sds*I*Wp 5467 lbs Fp * omega need not be greater than Fp-max Fp-omega 2343 Load Combinations LRFD DL LL Eh or W Ev Sds Total Horiz Total Vert LC1 (eq. 16-1) 1.4 0 0 0 1 0 4586 LC2 (eq. 16-2) 1.2 1.6 0 0 1 0 3931 LC3 (eq. 16-5) 1.2 0.5 1 683 1 2343 4615 LC4 (eq. 16-7) 0.9 0 1 683 1 2343 3632 LC5 (eq. 16-1) 1.4 0 0 0 -1 0 4586 LC6 (eq. 16-2) 1.2 1.6 0 0 -1 0 3931 LC7 (eq. 16-5) 1.2 0.5 1 -683 -1 2343 3248 LC8 (eq. 16-7) 0.9 0 1 -683 -1 2343 2265 note: Ev=0.2*Sds*D CLU3418 3000 WEST MACARTHUR SMARTLINK Mechanical Unit Anchorage NEQ. 20326 48V NETSURE VRLA BATTERY RACK 𝐹𝑝 =.∗ ∗ ∗ /(1+2*z/h) AT&T CLU3418 5 of 39 project by CASA location date 6/9/2025 client job no. 25-181 CLU3418 3000 WEST MACARTHUR SMARTLINK Note: For maximum tension load, consider Ev is in the opposite direction of the gravity. 2343 lbs C.G. 2265 lbs 1133 lbs 1133 lbs 4335 lbs 4335 lbs Mot=total horizontal*unit height/2 Mot=98406 lb.in T/C= Mot/ unit width T/C= 4335 lbs Vertical Reaction= Total Vertical/2 Vertical Reaction= 1133 lbs Net omega tension = Vertical Reaction-T/C Net omega tension =-3203 lbs CHECK ANCHORGE FOR PULLOUT AT&T CLU3418 6 of 39 project by CASA location date 6/9/2025 client job no. 25-181 CLU3418 3000 WEST MACARTHUR SMARTLINK Note: for maximum compression load, consider Ev is in the same direction of the gravity 2343 lbs 4615 lbs 2307 lbs 2307 lbs 4335 lbs 4335 lbs Mot=total horizontal*unit height/2 Mot=98406 lbs-in T/C= Mot/ unit width T/C=4335 lbs Vertical Reaction= Total Vertical/2 Vertical Reaction= 2307 lbs Net Omega Compression = Vertical Reaction+T/C Net Omega Compression= 6642 lbs (compression) Compression Force (lb)= 6642 Shear Force (lb)= 2343 < 3000 (V allow)OK Tension Force (lb)= 3203 < 1870 (T allow)Fails t/T + v/V= 2.49 <Fails(4.2.2, ESR 1917) Use Four (4) 5/8 inch diameter x 3-1/4 inch embedment Hilti Kwik Bolt TZ2 expansion anchors, (2) each side of unit (minimum), to attach unit to new pad on grade, per ESR-4266. Fill all holes in support rails with anchors, typical. See following pages for anchorage calcs. AT&T CLU3418 7 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 1 6/9/2025 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (3 1/4) hnom2 Item number: 2210271 KB-TZ2 5/8x4 3/4 Specification text: Hilti Æ 5/8 in Kwik Bolt TZ2 - CS with 3.75 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII, Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.394 in. Anchor plateR : lx x ly x t = 22.700 in. x 27.500 in. x 0.394 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 6.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] AT&T CLU3418 8 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 2 6/9/2025 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = -2,265; Vx = 2,343; Vy = 0; Mx = 0; My = 98,406; Mz = 0; yes 61 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1,817 586 586 0 2 0 586 586 0 3 1,817 586 586 0 4 0 586 586 0 Max. concrete compressive strain: 0.04 [‰] Max. concrete compressive stress: 194 [psi] Resulting tension force in (x/y)=(-9.850/0.000): 3,635 [lb] Resulting compression force in (x/y)=(10.612/0.000): 5,900 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*1,817 13,157 14 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**3,635 5,998 61 OK * highest loaded anchor **anchor group (anchors in tension) AT&T CLU3418 9 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 3 6/9/2025 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.16 106,704 Calculations Nsa [lb] 17,542 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 17,542 0.750 13,157 1,817 3.2 Concrete Breakout Failure Ncbg = (ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b) f Ncbg ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N 3.250 0.000 0.000 ∞1.000 cac [in.]kc l a f' c [psi] 11.500 21 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 190.13 95.06 1.000 1.000 1.000 1.000 6,152 Results Ncbg [lb]f concrete f seismic f nonductile f Ncbg [lb]Nua [lb] 12,304 0.650 0.750 1.000 5,998 3,635 AT&T CLU3418 10 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 4 6/9/2025 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*586 6,668 9 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**2,343 34,451 7 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.16 106,704 1.000 Calculations Vsa,eq [lb] 10,259 Results Vsa,eq [lb]f steel f Vsa,eq [lb]Vua [lb] 10,259 0.650 6,668 586 AT&T CLU3418 11 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 5 6/9/2025 4.2 Pryout Strength Vcpg = kcp [(ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.] 2 3.250 0.000 0.000 ∞ y c,N cac [in.]kc l a f' c [psi] 1.000 11.500 21 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 380.25 95.06 1.000 1.000 1.000 1.000 6,152 Results Vcpg [lb]f concrete f seismic f nonductile f Vcpg [lb]Vua [lb] 49,216 0.700 1.000 1.000 34,451 2,343 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.606 0.088 5/3 46 OK bNV = bz N + bz V <= 1 AT&T CLU3418 12 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 6 6/9/2025 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! AT&T CLU3418 13 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 7 6/9/2025 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 -9.850 -12.250 ---- 2 9.850 -12.250 ---- 3 -9.850 12.250 ---- 4 9.850 12.250 ---- 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (3 1/4) hnom2 Profile: no profile Item number: 2210271 KB-TZ2 5/8x4 3/4 Hole diameter in the fixture: df = 0.687 in. Maximum installation torque: 481 in.lb Plate thickness (input): 0.394 in. Hole diameter in the base material: 0.625 in. Recommended plate thickness: not calculated Hole depth in the base material: 4.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti Æ 5/8 in Kwik Bolt TZ2 - CS with 3.75 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer AT&T CLU3418 14 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | CABINET ANCHORAGE Page: Specifier: E-Mail: Date: 8 6/9/2025 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. AT&T CLU3418 15 of 39 AT&T CLU3418 16 of 39 project by CASA location date 6/9/2025 client job no. 25-181 Seismic Ground Motion Values SDS =1.043 III Table 1.5-1 SD1 =N/A D § 11.4.3 D Table 11.6-1 Seismic Design Force Wpequip.(lb)Wpmounts(lb)ap Rp Ip 1+2(z/h)Ω 94.8 50 1.0 2.5 1.25 3.0 1.0 63.1 50 1.0 2.5 1.25 3.0 1.0 72.8 50 1.0 2.5 1.25 3.0 1.0 53.0 20 1.0 2.5 1.25 3.0 1.0 74.0 20 1.0 2.5 1.25 3.0 1.0 67.2 20 1.0 2.5 1.25 3.0 1.0 57.3 20 1.0 2.5 1.25 3.0 1.0 13.2 0 1.0 2.5 1.25 3.0 1.0 0.0 0 1.0 2.5 1.0 3.0 1.0 0.0 0 1.0 2.5 1.0 3.0 1.0 0.0 0 1.0 2.5 1.0 3.0 1.0 0.0 0 1.0 2.5 1.0 3.0 1.0 0.0 0 1.0 2.5 1.0 3.0 1.0 Fp min (lb)Fp (lb)Fp max (lb)ΩFp ELat (lb)+/- EVert (lb) 56.6 90.6 302.1 90.6 90.6 30.2 44.2 70.7 235.8 70.7 70.7 23.6 48.0 76.8 256.2 76.8 76.8 25.6 28.6 45.7 152.3 45.7 45.7 15.2 36.8 58.8 196.1 58.8 58.8 19.6 34.1 54.6 181.9 54.6 54.6 18.2 30.2 48.4 161.2 48.4 48.4 16.1 5.2 8.3 27.5 8.3 8.3 2.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Seismic Coefficients from Table 13.6-1 COMMSCOPE NNH4-65A-R6H4 RRUS 32 B30 Seismic Loads Table RRUS 4449 B5/B12 0 Item KATHREIN 800-10964K ERICSSON AIR6419 B77D COMMSCOPE NNH4-65A-R6H4 Item CLU3418 3000 WEST MACARTHUR SMARTLINK Risk Category Site Class SDC Seismic Demands on Nonstructural Components ASCE 7-16 Wind and Seismic Analysis for Appurtenances per ASCE 7-16 & TIA 222-H RRUS 32 B30 RRUS 4449 B5/B12 RRUS 4890 B25/B66 RRUS 4494 B14/B29 COMMSCOPE CBC61923T-DS-43 0 KATHREIN 800-10964K ERICSSON AIR6419 B77D 0 0 RRUS 4494 B14/B29 COMMSCOPE CBC61923T-DS-43 0 0 0 0 0 0 RRUS 4890 B25/B66 AT&T CLU3418 17 of 39 project by CASA location date 6/9/2025 client job no. 25-181 CLU3418 3000 WEST MACARTHUR SMARTLINK FA =q z*G h*(EPA)A Wind Force (§2.6.11.2)qz*Gh*Ka*Ca =47.1 lb Gh Gust effect factor from §2.6.9 Gh =1 (EPA)A =K a*C a*A p Ka Effective projected area coefficient from §2.6.11.2 Ka =1.0 Ap Effective projected area qh, qz =0.00256 *K z*K zt*K s*K d*K e*V 2 qz =33.6 psf Kz Velocity pressure exposure coeff. Defined in §2.6.5.2 Kz =1.17 Kzt Topographic factor defined in §2.6.6.2 Kzt =1.0 Ks Rooftop wind speed-up factor from §2.6.7 Ks =1.1 Kd Wind directionality factor from Table 2-2 Kd =1 Ke Ground elevation factor defined in §2.6.8 Ke =1.0 V Basic wind speed V =101 mph Ca Net force coeff. From Table 2-9 Ca =1.4 0.017453293 h (in) w (in) t (in)Ap (ft2) @ 0o Ap (ft2) @ 30o Ap (ft2) @ 60o Ap (ft2) @ 90o 67.0 22.0 10.0 10.24 11.19 9.15 4.65 28.3 16.1 7.9 3.16 3.52 2.93 1.55 59.0 19.6 7.8 8.03 8.55 6.78 3.20 27.2 12.1 7.0 2.29 2.64 2.29 1.32 14.9 13.1 9.3 1.36 1.66 1.51 0.96 20.6 15.7 7.0 2.24 2.44 1.99 1.00 17.5 15.1 5.6 1.84 1.93 1.51 0.68 7.8 6.9 4.6 0.37 0.45 0.40 0.25 0.0 0.0 0.0 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.00 0.00 0.00 0.00 FA (lb) @ 60o FA (lb) @ 90o FA Max (lb) 430.4 218.9 526.6 137.7 73.1 165.5 319.2 150.4 402.4 107.7 62.2 124.2 71.1 45.3 77.9 93.5 47.1 114.8 70.9 32.0 90.8 18.9 11.7 21.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 FA (lb) @ 30o 526.6 165.5 402.4 FA (lb) @ 0o 481.6 148.9 0.0 0.0 0.0 0.0 377.9 107.5 Wind Effective Projected Areas Wind Loads Table 0 RRUS 4494 B14/B29 COMMSCOPE CBC61923T-DS-43 0 0 21.1 RRUS 32 B30 Item Wind and Seismic Analysis for Appurtenances per ASCE 7-16 & TIA 222-H Design Wind Loads TIA-222-H *Per §16.6 Wind shall be considered to occur from directions in 30 degree maximum increments around a mounting system and shall include directions normal and parallel to the face of mount. 114.8 0.0 0.0 17.6 86.3 RRUS 4449 B5/B12 90.8 0 77.9 124.2 105.4 63.8 ERICSSON AIR6419 B77D COMMSCOPE NNH4-65A-R6H4 Item KATHREIN 800-10964K RRUS 4449 B5/B12 RRUS 32 B30 0.0 0.0 RRUS 4890 B25/B66 COMMSCOPE CBC61923T-DS-43 0 0 RRUS 4494 B14/B29 0.0 0.0 0 0 0 RRUS 4890 B25/B66 0 KATHREIN 800-10964K ERICSSON AIR6419 B77D COMMSCOPE NNH4-65A-R6H4 AT&T CLU3418 18 of 39 project by CASA location date 6/9/2025 client job no. 25-181 CLU3418 3000 WEST MACARTHUR SMARTLINK Wp (lb) 144.8 113.1 122.8 73.0 94.0 87.2 77.3 13.2 0.0 0.0 0.0 0.0 0.0 DL ELat EVert W L LC1 1.4 0 0 0 0 LC2 1.2 0 0 1 0 LC3 1.2 1 1 0 0 Total Vert Total Horiz Total Vert Total Horiz Total Vert(+Ev)Total Horiz Vertical Horizontal 202.7 0.0 173.8 526.6 204.0 90.6 204.0 526.6 158.3 0.0 135.7 165.5 159.2 70.7 159.2 165.5 171.9 0.0 147.4 402.4 173.0 76.8 173.0 402.4 102.2 0.0 87.6 124.2 102.8 45.7 102.8 124.2 131.6 0.0 112.8 77.9 132.4 58.8 132.4 77.9 122.1 0.0 104.6 114.8 122.8 54.6 122.8 114.8 108.2 0.0 92.8 90.8 108.9 48.4 108.9 90.8 18.5 0.0 15.8 21.1 18.6 8.3 18.6 21.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0 0 0.0 0.0 0.0 0.0 0.0 0.0 RRUS 4449 B5/B12 0 0 0 ELat (lb) 90.6 76.8 45.7 77.9 LRFD Load Combinations 114.8 0.0 COMMSCOPE NNH4-65A-R6H4 Load Case 1 Load Case 2 Load Case 3 Factored Design Forces (lb) KATHREIN 800-10964K ERICSSON AIR6419 B77D RRUS 32 B30 RRUS 4890 B25/B66 RRUS 4494 B14/B29 COMMSCOPE CBC61923T-DS-43 0 0 Factored Loads 0 0.0 0.0 0.0 KATHREIN 800-10964K COMMSCOPE NNH4-65A-R6H4 RRUS 4890 B25/B66 Wind and Seismic Analysis for Appurtenances per ASCE 7-16 & TIA 222-H Design Loads Summary Seismic Forces Wind Forces 54.6 0.0 0.0 124.2 165.5 RRUS 4494 B14/B29 COMMSCOPE CBC61923T-DS-43 Item FA Max. (lb) 526.6 48.4 8.3 +/- Evert (lb) 30.2 25.6 15.2 19.6 18.2 16.1 2.8 90.8 21.1 *Max Wind and Seismic forces will be analyzed in each orthogonal direction for each component. The worst case appurtenance loading will be used for the (E) mount structure. 0 0.0 0.0 0.0 58.8 RRUS 32 B30 RRUS 4449 B5/B12 ERICSSON AIR6419 B77D 70.7 23.6 402.4 AT&T CLU3418 19 of 39 project by CASA location date 6/9/2025 client job no. 25-181 CLU3418 3000 WEST MACARTHUR SMARTLINK Ecc T1 Fh d V Fv T2 Fh (lb) Fv (lb)Ecc (in) d (in)T1 (lb) gov.V (lb) Stress % 526.6 204.0 12 67.0 299.8 102.0 7.41%OK 165.5 159.2 12 28.3 150.3 79.6 4.52%OK 402.4 173.0 12 59.0 236.4 86.5 6.01%OK 124.2 102.8 12 27.2 107.5 51.4 3.08%OK 77.9 132.4 12 14.9 145.6 66.2 4.07%OK 114.8 122.8 12 20.6 129.0 61.4 3.68%OK 90.8 108.9 12 17.5 120.1 54.4 3.35%OK 21.1 18.6 12 7.8 39.2 9.3 0.85%OK 0.0 0.0 12 0.0 #DIV/0!0.0 #DIV/0!#DIV/0! 0.0 0.0 12 0.0 #DIV/0!0.0 #DIV/0!#DIV/0! 0.0 0.0 12 0.0 #DIV/0!0.0 #DIV/0!#DIV/0! 0.0 0.0 12 0.0 #DIV/0!0.0 #DIV/0!#DIV/0! 0.0 0.0 12 0.0 #DIV/0!0.0 #DIV/0!#DIV/0! FU=60.0 ksi Bolt Diameter=0.5 in Max V=0.102 kip Max T=0.300 kip Φ (Resistance Factor) =0.75 Ab =0.196 in^2 Fnv =24 ksi (A307) Fnt =45 ksi (A307) fv = Vu bolt / Ab =0.5 ksi Vallow = Φ Fnv Ab =3.5 kip >0.102 kip OK Tallow = Φ Fnt Ab =6.6 kip >0.300 kip OK Combined Shear and Tension: F'nt = 1.3F'nt -(Fnt x fv)/ΦFnv < Fnt =57.8 kip <45 kip =45 kip Rn = F'nt x Ab =8.836 kip ΦRn = F'nt x Ab =6.627 kip >0.300 kip OK RRUS 32 B30 RRUS 4449 B5/B12 RRUS 4890 B25/B66 RRUS 4494 B14/B29 COMMSCOPE CBC61923T-DS-43 0 1/2" ø A-307 U-Bolt @ Top & Bottom Appurtenance Anchorage 0 0 0 Wind and Seismic Analysis for Appurtenances per ASCE 7-16 & TIA 222-H KATHREIN 800-10964K COMMSCOPE NNH4-65A-R6H4 ERICSSON AIR6419 B77D 0 AT&T CLU3418 20 of 39 DE T A I L A PA R T S L I S T NE T W T . UN I T W T . LE N G T H PA R T D E S C R I P T I O N PA R T N O . QT Y IT E M 18 . 1 2 18 . 1 2 8" S T A N D - O F F A R M / W A L L M O U N T X- W W M 0 1 1 1 0. 1 0 0. 0 3 5/ 8 " H D G L O C K W A S H E R G5 8 L W 4 2 0. 1 4 0. 0 3 5/ 8 " H D G A 3 2 5 F L A T W A S H E R A5 8 F W 4 3 0. 5 2 0. 1 3 5/ 8 ' ' H D G A 3 2 5 H E X N U T A5 8 N U T 4 4 1. 3 4 0. 3 3 5/ 8 ' ' x 2 - 1 / 2 " H D G A 3 2 5 H E X B O L T A5 8 2 1 1 2 4 5 1. 3 1 0. 6 6 1/ 2 " X 2 - 1 / 2 " X 4 - 1 / 2 " X 2 " G A L V . U - B O L T X- U B 1 2 1 2 2 6 1. 3 9 0. 7 0 1/ 2 " X 3 " X 5 " X 2 " G A L V U - B O L T X- U B 1 3 0 0 2 6 1. 5 4 0. 7 7 1/ 2 " X 3 - 5 / 8 " X 5 - 1 / 2 " X 3 " G A L V U - B O L T X- U B 1 3 5 8 2 6 0. 1 4 0. 0 3 1/ 2 " H D G U S S F L A T W A S H E R G1 2 F W 4 7 0. 2 9 0. 0 7 1/ 2 ' ' H D G H E A V Y 2 H H E X N U T G1 2 N U T 4 8 0. 0 6 0. 0 1 1/ 2 " H D G L O C K W A S H E R G1 2 L W 4 9 A DE S C R I P T I O N DR A W I N G U S A G E C H E C K E D B Y EN G . A P P R O V A L DR A W N B Y DW G . N O . CP D N O . RH 1 8 1 OF 1 BM C 5 / 1 0 / 2 0 1 0 3/ 2 3 / 2 0 1 0 WW M 0 1 8" S T A N D - O F F WI R E L E S S W A L L M O U N T . SI T E P R O 1 47 1 4 CU S T O M E R WW M 0 1 CL A S S S U B PA R T N O . 81 0 1 PAGE TO L E R A N C E S O N D I M E N S I O N S , U N L E S S O T H E R W I S E N O T E D A R E : SA W E D , S H E A R E D A N D G A S C U T E D G E S (± 0 . 0 3 0 " ) DR I L L E D A N D G A S C U T H O L E S (± 0 . 0 3 0 " ) - N O C O N I N G O F H O L E S LA S E R C U T E D G E S A N D H O L E S (± 0 . 0 1 0 " ) - N O C O N I N G O F H O L E S BE N D S A R E ± 1 / 2 D E G R E E AL L O T H E R M A C H I N I N G (± 0 . 0 3 0 " ) AL L O T H E R A S S E M B L Y (± 0 . 0 6 0 " ) TO L E R A N C E N O T E S PR O P R I E T A R Y N O T E : TH E D A T A A N D T E C H N I Q U E S C O N T A I N E D I N T H I S D R A W I N G A R E P R O P R I E T A R Y I N F O R M A T I O N O F V A L M O N T IN D U S T R I E S A N D C O N S I D E R E D A T R A D E S E C R E T . A N Y U S E O R D I S C L O S U R E W I T H O U T T H E C O N S E N T O F VA L M O N T I N D U S T R I E S I S S T R I C T L Y P R O H I B I T E D . En g i n e e r i n g Su p p o r t T e a m : 1 - 8 8 8 - 7 5 3 - 7 4 4 6 va l m o n t Lo c a t i o n s : Ne w Y o r k , N Y At l a n t a , G A Lo s A n g e l e s , C A Pl y m o u t h , I N Sa l e m , O R Da l l a s , T X TO T A L W T . # 2 4 . 9 5 5 4 3 2 1 6 7 8 9 2- 3 / 8 " O D P I P E , 2 - 7 / 8 " O D P I P E o r 3 - 1 / 2 " O D P I P E , PI P E N O T I N C L U D E D . AT&T CLU3418 21 of 39 April 23, 2018 Site Pro 1 / Valmont Mounting System: Part Number = WWM01 and MM01 Part Description = 8” Wireless Stand Off Arm Wall Mount Mount EPA (0 Degree tilt): EPAN = 0.50 sq-Ft EPAN (0.5” Ice) = 0.75 sq-Ft EPAN (1” Ice) = 1.00 sq-Ft EPAT = 0.35 sq-Ft EPAT (0.5” Ice) = 0.52 sq-Ft EPAT (1” Ice) = 0.75 sq-Ft Weight = 20 lb Weight (0.5” Ice) =29 lb Weight (1” Ice) = 42 lb Classification Rating: None Design Standards ANSI/TIA-222-G-2012 ANSI/TIA-222-H-2018 ASCE 7-10 International Building Code 2012 TIA-5053 Analysis and Modeling Technique An elastic, three-dimensional, frame, truss model was developed to examine the structural behavior of the mount. All orientations in the engineering model correspond with the assembly drawing constraints. The mount was analyzed with one (1) mounting locations (antenna, mount pipe, radio, and any other appurtenance) evenly spaced across the face of the mount, with no (0) vertical eccentricity. Wind directions considered were perpendicular (normal) to the face of the frame and at 30 degree increments up to 90 degrees (tangential) to the face of the frame. Wind, dead weight and ice weight on the mount was also included in the model. Modeling Software Autodesk Inventor ANSYS Workbench AT&T CLU3418 22 of 39 Analysis Design Criteria Maximum Mount Height 400' Maximum Ultimate Wind Speed, no Ice 180 mph 3 sec gust Maximum Design Wind Speed, no Ice 140 mph 3 sec gust Maximum Design Wind Speed on Ice 60 mph 3 sec gust Structure Class I or II Exposure Category B or C Topographic Category I Maximum Design Ice Thickness, ti 1" (2.75” factored ice) Wind Direction Probability Factor, Kd 0.95 Gust Effect Factor, Gh 1.0 Capacity Results The following factored loads at each mounting location represent the capacity of the mount based on the criteria and modeling technique described above. no to zo ni ti zi nm tm zm M * In addition to a nominal Live Load of two (2) 250 lb concentrated on either side of a mounting location to provide access for climbers. AT&T CLU3418 23 of 39 Seismic Results The following Seismic Response Coefficient chart below represent the allowable weight capacity of the bracket based on the criteria and modeling technique described in TIA-222-H Section 2.7.7.1.1. Total allowable seismic shear must be less than or equal to the Capacity Results (Fno) stated above. 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0.000 2.000 4.000 6.000 8.000 10.000 12.000To t a l W e i g h t ( D e a d L o a d + M o u n t ) ) Seismic Response Coefficient Cs Weight Capacity VS. Seismic Response Coefficient AT&T CLU3418 24 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 1 6/9/2025 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 5/8 (3 1/4) hnom2 Item number: 2210279 KB-TZ2 5/8x6 SS304 Specification text: Hilti Æ 5/8 in Kwik Bolt TZ2 - SS 304 with 3.75 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII, Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 8.063 in. x 8.063 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x 0.250 in. Base material: cracked concrete, 4000, fc' = 4,000 psi; h = 7.250 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] AT&T CLU3418 25 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 2 6/9/2025 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 527; Vx = 527; Vy = -145; Mx = 1,740; My = 0; Mz = 0; yes 10 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 18 137 132 -36 2 18 137 132 -36 3 273 137 132 -36 4 273 137 132 -36 Max. concrete compressive strain: 0.01 [‰] Max. concrete compressive stress: 23 [psi] Resulting tension force in (x/y)=(0.000/2.620): 583 [lb] Resulting compression force in (x/y)=(-0.000/-3.833): 56 [lb] Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*273 14,132 2 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**583 6,439 10 OK * highest loaded anchor **anchor group (anchors in tension) AT&T CLU3418 26 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 3 6/9/2025 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.16 114,604 Calculations Nsa [lb] 18,843 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 18,843 0.750 14,132 273 3.2 Concrete Breakout Failure Ncbg = (ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b) f Ncbg ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.]y c,N 3.250 0.000 2.620 ∞1.000 cac [in.]kc l a f' c [psi] 6.500 21 1.000 4,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 248.06 95.06 1.000 0.650 1.000 1.000 7,782 Results Ncbg [lb]f concrete f seismic f nonductile f Ncbg [lb]Nua [lb] 13,207 0.650 0.750 1.000 6,439 583 AT&T CLU3418 27 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 4 6/9/2025 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*137 8,034 2 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**547 28,429 2 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.16 114,604 1.000 Calculations Vsa,eq [lb] 12,360 Results Vsa,eq [lb]f steel f Vsa,eq [lb]Vua [lb] 12,360 0.650 8,034 137 AT&T CLU3418 28 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 5 6/9/2025 4.2 Pryout Strength Vcpg = kcp [(ANc ANc0)y ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b) f Vcpg ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ec,N = (1 1 + 2 e' N 3 hef )£ 1.0 ACI 318-19 Eq. (17.6.2.3.1) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ec1,N [in.]ec2,N [in.]ca,min [in.] 2 3.250 0.000 0.000 ∞ y c,N cac [in.]kc l a f' c [psi] 1.000 6.500 21 1.000 4,000 Calculations ANc [in.2]ANc0 [in.2]y ec1,N y ec2,N y ed,N y cp,N Nb [lb] 248.06 95.06 1.000 1.000 1.000 1.000 7,782 Results Vcpg [lb]f concrete f seismic f nonductile f Vcpg [lb]Vua [lb] 40,612 0.700 1.000 1.000 28,429 547 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.090 0.019 5/3 2 OK bNV = bz N + bz V <= 1 AT&T CLU3418 29 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 6 6/9/2025 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! AT&T CLU3418 30 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 7 6/9/2025 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c+y 1 -3.000 -3.000 ---- 2 3.000 -3.000 ---- 3 -3.000 3.000 ---- 4 3.000 3.000 ---- 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 5/8 (3 1/4) hnom2 Profile: Square HSS (AISC), HSS4X4X.25; (L x W x T) = 4.000 in. x 4.000 in. x 0.250 in. Item number: 2210279 KB-TZ2 5/8x6 SS304 Hole diameter in the fixture: df = 0.687 in. Maximum installation torque: 722 in.lb Plate thickness (input): 0.500 in. Hole diameter in the base material: 0.625 in. Recommended plate thickness: not calculated Hole depth in the base material: 4.250 in. Drilling method: Hammer drilled Minimum thickness of the base material: 5.500 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti Æ 5/8 in Kwik Bolt TZ2 - SS 304 with 3.75 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer AT&T CLU3418 31 of 39 www.hilti.com Hilti PROFIS Engineering 3.1.15 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | Concrete - Dec 15, 2021 Page: Specifier: E-Mail: Date: 8 6/9/2025 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. AT&T CLU3418 32 of 39 AT&T CLU3418 33 of 39 project by CASA location date 6/9/2025 client job no. 25-181 Exposure Category = C Wall Height = 5.5 ft F = qh*G*Cf*As = 32.0 psf qh =0.00256KzKztKdKeV^2 = 26.0 psf Kz = 1.17 Kzt = 1.0 Ke =1.0 Kd =0.85 V = 101 MPH G = 0.85 Cf = 1.45 As = 1.0 ft^2 CLU3418 3000 WEST MACARTHUR SMARTLINK Wind Analysis ASCE 7 SECTION 29.3.1 Solid Freestanding Walls and Solid Signs (N) FRP SCREEN WALL AT&T CLU3418 34 of 39 project by CASA location date 6/9/2025 client job no. 25-181 Wwind= 32.0 psf H= 5.5 ft h= 5.5 ft LBR1=3.7 ft LBR2=3.9 ft L=3.0 ft L1=2.5 ft L2=3.0 ft L3=2.5 ft h'1=2.75 ft h'2=2.75 ft h'3=0.0 ft CLU3418 3000 WEST MACARTHUR SMARTLINK FRP Wind Screen (N) FRP SCREEN WALL AT&T CLU3418 35 of 39 project by CASA location date 6/9/2025 client job no. 25-181 Wwind= 32.0 psf L = 3 ft h= 5.5 ft w = Wwind x h/2 = 88.0 plf R = wL/2 =132 lb Mu = wL2/8 =1.2 k-in R = Vu =0.132 k Section Properties Material Properties Calculated A =1.92 in2 EL,f =1600 ksi ΦMn,mat. rup.=20.3 k-in I =3.04 in4 EL,w =1600 ksi ΦMn,loc. stab.=60.0 k-in S =1.04 in3 ET,f =800 ksi ΦMn,ltbuckling.=317.7 k-in bf =4.00 in ET,w =800 ksi ΦVn, mat. rup. =12.5 k h=4.00 in GLT=450 ksi ΦVn, wsbuckling =25.1 k tf =0.25 in VLT=0.32 tw=0.25 in E = 2600 ksi FL=30 ksi FLT=10 ksi Mn Due to Material Rupture: Mn,mat. rup.=31.2 k-in Mn Due to Local Stability: Compression Flange Local Buckling kr=0.875 ξ= 0.259 fcr=72.093 ksi Web Local Buckling fcr=183.316 ksi Nominal flexural strength due to local stability Mn,loc. stab. =75.0 k-in TRY FRP 4x4x1/4 ANGLE CLU3418 3000 WEST MACARTHUR SMARTLINK FRP Wind Screen DESIGN BEAM B1 AT&T CLU3418 36 of 39 project by CASA location date 6/9/2025 client job no. 25-181 CLU3418 3000 WEST MACARTHUR SMARTLINK Mn Due to Lateral Torsional Buckling: DJ=5561.8 k-in2 Cb=1.0 Mn,ltbuckling =453.9 k-in Vu Due to Material Rupture In Shear: Vn, mat. rup. =19.2 k Vu Due to Web Shear Buckling: = 1156 ksi = 1131 ksi = 13.2 = 13.0 = 16.4 = 16.3 Vn, wsbuckling =31.4 k Moment & Shear Capacity: Mu =1.2 k-in <20.3 k-in OK Vu =0.1 k <12.5 k OK AT&T CLU3418 37 of 39 project by CASA location date 6/9/2025 client job no. 25-181 R= 0.528 k Py=0.581 k H= 5.5 ft Px=0.528 k h= 5.5 ft Pu=0.785 k L1=2.5 ft h'1=2.8 ft h'2=2.8 ft h'3=0.0 ft LBR1=3.7 ft K=1.0 Section Properties Material Properties A =1.92 in2 EL=2500 ksi I =3.04 in4 GLT=450 ksi S =1.04 in3 FL c=30 ksi b =4.00 in h =4.00 in t =0.25 in r =1.26 in Effective Slenderness Ratio: = 35 <= 109 AND <300 OK = 35 Factored Critical Stress in Compression: Fcrx =19.7 ksi Fcrft =1.8 ksi ΦPn =2.7 k Pu =0.785 k <2.700 k <40.3 k OK TRY FRP 4x4x1/4 Equal Leg Angle CLU3418 3000 WEST MACARTHUR SMARTLINK FRP Wind Screen DESIGN BEAM Brace BR1 AT&T CLU3418 38 of 39 project by CASA location date 6/9/2025 client job no. 25-181 R2= 0.528 k Py2=0.440 k L= 3.0 ft Px2=0.528 k L2=3.0 ft Pu2=0.687 k L3=2.5 ft LBR2=3.9 ft K=1.0 Section Properties Material Properties A =1.92 in2 EL=2500 ksi I =3.04 in4 GLT=450 ksi S =1.04 in3 FL c=30 ksi b =4.00 in h =4.00 in t =0.25 in r =1.26 in Effective Slenderness Ratio: = 37 <= 117 AND <300 OK = 37 Factored Critical Stress in Compression: Fcrx =17.8 ksi Fcrft =1.8 ksi ΦPn =2.7 k Pu =0.687 k <2.700 k <40.3 k OK TRY FRP L4x4x1/4 Equal Leg Angle CLU3418 3000 WEST MACARTHUR SMARTLINK FRP Wind Screen DESIGN BEAM Brace BR2 AT&T CLU3418 39 of 39