HomeMy WebLinkAbout2051 S Garnsey St - REV 2 - PlanFOUNDATION PLAN SCALE: 1/4" = 1' 1. PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM 4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. 2. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 3. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS IN ACCORDANCE WITH TABLE 2306.5 OF THE LABC. 4. FOUNDATION ANCHOR BOLTS IN WALLS WITH LATERAL LOADS GREATER THAN 300 POUNDS/FOOT SHALL HAVE AN APPROVED PLATE WASHER UNDER EACH NUT; AND THE NUTS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 5. UNO THE FOUNDATION BOLTS SHALL BE 5/8" DIA. WITH 3"x3"x1/4" PLATE WASHERS EMBEDDED AT LEAST 9 INCHES INTO THE CONCRETE (OR) MASONRY FOUNDATION SPACED NOT MORE THAN 6 FEET APART. 6. MIN 2 BOLTS PER PIECE OF SILL PLATE AND ONE LOCATED WITHIN 12" AND NOT LESS THAN 7 BOLT DIAMETER OR 4-3/8" OF EACH END OF EACH SILL PLATE. 7. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 8. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. PLATE WASHERS ARE REQUIRED FOR ALL HOLDOWNS. 9. ALL FOUNDATION EXCAVATIONS MUST BE OBSERVED AND APPROVED BY THE PROJECT ENGINEERING GEOLOGIST AND/OR PROJECT GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. 10. IF ADVERSE SOIL CONDITIONS ARE IN ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. 11. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 12. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. NOTES: DENOTES NEW FOOTING LEGEND: ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE JOINTS OCCURRING IN BRACED WALL PANELS SOLID BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL COMMON NAILS OR GALVANIZED BOX. 1" Ø BOLT - 3.5"x3.5"x3/8" b) 3 x STUDS AND BLOCKS BETWEEN ADJACENT PANELS c) 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING d) ALL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED. e) SQUARE PLATE WASHERS SHALL BE USED WITH ANCHOR BOLTS 5/8" Ø BOLT - 3"x3"x1/4" 7/8" Ø BOLT - 3"x3"x5/16" a) 3 x FOUNDATION SILL PLATES ALL SHEAR WALLS WITH A SHEAR VALUE GREATER THAN 300 lb/ft SHOULD BE PROVIDED: 3/4" Ø BOLT - 3"x3"x5/16" d) STAGGER NAILS IF NAIL SPACING IS LESS THAN 2" O.C. 2. DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. 3. AN AITC CERTIFICATE OF INSPECTION FOR ALL GLU-LAM BEAMS INCLUDING PARALLAM BEAMS SHALL BE SUBMITTED TO THE BUILDING AND SAFETY DEPT. PRIOR TO ERECTION. 4. GLUE LAM BEAMS MUST BE FABRICATED IN A LADBS LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5A, 2005 NDS SUPP. 6. SHOP WELDS MUST BE PERFORMED IN A LADBS LICENSED FABRICATORS SHOP. 8. ALL WOOD MEMBERS MUST BE GRADE MARKED WITH GRADE AND SPECIES. 9. BEARING WALL STUDS CANNOT BE NOTCHED MORE THAN 25% OF THEIR WIDTH. BORED HOLES CANNOT HAVE A DIAMETER GREATER THAN 40% OF THE STUD WIDTH 10. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 11. STRUCTURAL OBSERVATION IS REQUIRED FOR ALL PLYWOOD SHEAR WALLS WITH A DESIGN LOAD OVER 300 PLF. 12. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 14. EXTERIOR STAIRS AND BALCONIES MUST BE POSITIVELY ATTACHED TO THE STRUCTURE WITHOUT THE USE OF TOE NAILS OR NAILS IN WITHDRAWAL. 16. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/ COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 17. CONTINUOUS SPECIAL INSPECTION REQUIRED BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH f'c>2500 PSI, HIGH STRENGTH BOLTING, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 7. LADBS LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 18. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS MORE THAN 4 INCHES ON CENTER. 13. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 15. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. 1. ALL WALLS OVER 10' IN HEIGHT TO BE 2x6 @16" O.C. FRAMING. NOTES: FRAMING BOUNDARY 4x4 POST INTERIOR WALL (U.N.O.) SHEAR WALL PER PLAN FRAMING MEMBERS LEGEND: POST FROM ABOVE ON TOP OF BEAM/HEADER ON TOP OF BEAM/HEADER POST W/STRAP OR HOLDOWN FROM ABOVE ON TOP OF POST BELOW POST FROM ABOVE W/STRAP OR HOLDOWN POST FROM ABOVE ON TOP OF POST BELOW 19. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 20. FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LADBS. CONTINUOUS INSPECTION IS REQUIRED, 21. A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE 4x6 POST EXTERIOR WALL (U.N.O.) ROOF FRAMING PLAN SCALE: 1/4" = 1' DENOTES EXISTING FOOTING 380 650 498 PLATE TO BLKG. REQUIREMENTS SDS 1/4"x 6 SDS 1/4"x 6 SDS 1/4"x 6 SHEAR WALL SCHEDULE 12" O.C. PANEL NAILING 12" O.C. 12" O.C. 12" O.C. 10d @215/32" PLYWOOD 15/32" PLYWOOD STRUCTURAL 1 STRUCTURAL 1 STRUCTURAL 1 15/32" PLYWOOD4 3 2" O.C. 10d @ 10d @ 3" O.C. 4" O.C. OF SHEAR STRUCTURAL 1 WALL MATERIAL 15/32" PLYWOOD DESCRIPTION TYPE 1 PERIMETER 6" O.C. 10d @ 10d @ 12" O.C. OR LPT4 @ 8" O.C. 8" O.C. OR 10" O.C. OR LPT4 @ 10" O.C. LPT4 @ 12" O.C. 10d @ 10d @ A35 @ A35 @ @ 4" O.C. @ 8" O.C. @ 6" O.C. REQUIREMENTS BLKG. TO PLATE 16" O.C. OR CONNECTION LPT4 @ 16" O.C. 10d @ FIELD A35 @ A35 @ CONNECTION @ 6" O.C. 20d NAILS OR 5/8" Ø @ 24" O.C. 3/4" Ø @ 32" O.C. 3/4" Ø @ 32" O.C. 5/8" Ø @ 32" O.C. 3/4" Ø @ 48" O.C. OR OR 9" 9" 9" 9" 9" 3/4" Ø @ 6'-0" O.C. 5/8" Ø @ 48" O.C. 5/8" Ø @ 32" O.C. ANCHOR BOLTS FOUND CONN. SILL PLATE TO OR 9" 255 ANCHOR EMB. BOLTS 9" 9" ALLOWABLE SHEAR LOAD PLF MIN 12" WIDTH x 18" DEPTH MIN 12" WIDTH x 24" DEPTH No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # AD D R E S S : 20 5 1 S G A R N S E Y S T . , SA N T A A N A , C A 9 2 7 0 7 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 S.S. S.S. 24-1021 11/5/2024 8/4/2025 1/4” = 1’-0” S1 RO O F & F O U N D A T I O N PL A N Revision to 101122391 (issued on 5/2/25) REV 2 #101124644 APPROVALS:BLDG - CSG No DATE REVISIONS BY SEAL CITY APPROVAL SHEET DRAWN BY CHECKED DATE DRAWN DATE SCALE JOB # AD D R E S S : 20 5 1 S G A R N S E Y S T . , SA N T A A N A , C A 9 2 7 0 7 OW N E R : 818 747 7269 | shant.sps@gmail.com 15445 Ventura Blvd. #63, Sherman Oaks,CA 91403 S.S. S.S. 24-1021 11/5/2024 8/4/2025 N.T.S. S2 DE T A I L STRUCTURAL CALCULATIONS PROJECT: 2049 S Garnsey St., Santa Ana, CA 92707 JOB #24-1021 08-04-25 BY: Shant Shahbaz Roof: D.L (psf)16 L.L (psf)20 Floor:Wall: D.L (psf)16 L.L (psf)15 10 L.L (psf)40 15 D.L. =Dead Load T.A = Tributary Area L.L = Live Load wD = (T.A.i * D.L.i) wL = (T.A.i * L.L.i) Deck:Ceiling D.L (psf)16 D.L (psf) L= Length L.L (psf) Roof Framing: L.L (psf)60 ←wD, wL RR (1) L (ft)9' T.A. (ft)1.33 wD 21 wL 27 2-2 x 4 @ 16" O.C. (No.2)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 9' ←D, wL CJ (1) L (ft)16.5' T.A. (ft)1.33 wD 13 wL 20 2 x 10 @ 16" O.C. (No.2)↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 16.5' ←D, wL HDR(1) L (ft)2' T.A.roof (ft)3 ceilling (ft)0 wD 48 wL 60 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 2' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com Roof Framing: ←wD, wL HDR(2) L (ft)4' T.A.roof (ft)9 ceilling (ft)9 wD 234 wL 315 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 4' ←D, wL HDR(3) L (ft)3' T.A.roof (ft)11 ceilling (ft)9 wD 266 wL 355 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 3' ←D, wL HDR(4) L (ft)6' T.A.roof (ft)9 ceilling (ft)0 wD 144 wL 180 4 x 8 (No. 2) ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 6' ←D, wL HDR(5) L (ft)6' T.A.roof (ft)9 ceilling (ft)9 wD 234 wL 315 4 x 8 (No. 2) ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 6' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com Roof Framing: ←wD, wL HDR(6) L (ft)6' T.A.roof (ft)9 ceilling (ft)9 wD 234 wL 315 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 6' SPS ENGINEERING 818 747 7269 | shant.sps@gmail.com Wood Beam LIC# : KW-06019339, Build:20.25.05.07 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: garnsey st.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 2-2x4 Span = 9.0 ft 1 2 D(0.0160) L(0.020) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0160, L = 0.020 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.487: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 4.500 ft 21.79 psi= = 1,466.25 psi 2-2x4Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 180.00 psi== Section used for this span 2-2x4 Maximum Shear Stress Ratio 0.121 : 1 8.737 ft= = 714.12 psi Maximum Deflection 467 <360 259 Ratio =0 <240 Max Downward Transient Deflection 0.231 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.416 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L+H n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 9.0 ft 1 0.241 0.060 0.90 1.500 1.151.00 1.00 0.16 317.4 1,319.6 0.07 162.01.00 9.71.00 1.00+D+L+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.487 0.121 1.00 1.500 1.151.00 1.00 0.36 714.1 1,466.3 0.15 180.01.00 21.81.00 1.00+D+Lr+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.173 0.043 1.25 1.500 1.151.00 1.00 0.16 317.4 1,832.8 0.07 225.01.00 9.71.00 1.00+D+S+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.188 0.047 1.15 1.500 1.151.00 1.00 0.16 317.4 1,686.2 0.07 207.01.00 9.71.00 Wood Beam LIC# : KW-06019339, Build:20.25.05.07 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:RR1 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: garnsey st.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+0.750Lr+0.750L+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.336 0.083 1.25 1.500 1.151.00 1.00 0.31 614.9 1,832.8 0.13 225.01.00 18.81.00 1.00+D+0.750L+0.750S+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.365 0.091 1.15 1.500 1.151.00 1.00 0.31 614.9 1,686.2 0.13 207.01.00 18.81.00 1.00+D+0.60W+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.135 0.034 1.60 1.500 1.151.00 1.00 0.16 317.4 2,346.0 0.07 288.01.00 9.71.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.262 0.065 1.60 1.500 1.151.00 1.00 0.31 614.9 2,346.0 0.13 288.01.00 18.81.00 1.00+D+0.750L+0.750S+0.450W+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.262 0.065 1.60 1.500 1.151.00 1.00 0.31 614.9 2,346.0 0.13 288.01.00 18.81.00 1.00+0.60D+0.60W+0.60H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.081 0.020 1.60 1.500 1.151.00 1.00 0.10 190.4 2,346.0 0.04 288.01.00 5.81.00 1.00+D+0.70E+0.60H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.135 0.034 1.60 1.500 1.151.00 1.00 0.16 317.4 2,346.0 0.07 288.01.00 9.71.00 1.00+D+0.750L+0.750S+0.5250E+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.262 0.065 1.60 1.500 1.151.00 1.00 0.31 614.9 2,346.0 0.13 288.01.00 18.81.00 1.00+0.60D+0.70E+H 1.500 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.081 0.020 1.60 1.500 1.151.00 1.00 0.10 190.4 2,346.0 0.04 288.01.00 5.81.00 . LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+L+H1 0.4156 4.533 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.162 0.162 Max Upward from Load Combinations 0.162 0.162 Max Upward from Load Cases 0.090 0.090 +D+H 0.072 0.072 +D+L+H 0.162 0.162 +D+Lr+H 0.072 0.072 +D+S+H 0.072 0.072 +D+0.750Lr+0.750L+H 0.140 0.140 +D+0.750L+0.750S+H 0.140 0.140 +D+0.60W+H 0.072 0.072 +D+0.750Lr+0.750L+0.450W+H 0.140 0.140 +D+0.750L+0.750S+0.450W+H 0.140 0.140 +0.60D+0.60W+0.60H 0.043 0.043 +D+0.70E+0.60H 0.072 0.072 +D+0.750L+0.750S+0.5250E+H 0.140 0.140 +0.60D+0.70E+H 0.043 0.043 D Only 0.072 0.072 L Only 0.090 0.090 H Only Wood Beam LIC# : KW-06019339, Build:20.25.06.16 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:CJ1 SPS Engineering 15445 Ventura Blvd. #63 Sherman Oaks. CA 91403 818 747 7269 Project File: garnsey st.ec6 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 Material Properties Beam Bracing :Beam bracing is defined as a set spacing over all spans Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 Unbraced Lengths First Brace starts at ft from Left-Most support Regular spacing of lateral supports on length of beam = 8.0 ft 2x10 Span = 16.50 ft 1 2 D(0.0130) L(0.020) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0130, L = 0.020 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.973: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 8.250 ft 26.85 psi= = 647.46 psi 2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 180.00 psi== Section used for this span 2x10 Maximum Shear Stress Ratio 0.149 : 1 0.000 ft= = 630.01 psi Maximum Deflection 700 <360 424 Ratio =0 <240 Max Downward Transient Deflection 0.283 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.466 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L+H n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 0.66Length = 7.949 ft 1 0.388 0.065 0.90 1.100 1.151.00 1.00 0.44 247.9 638.9 0.10 162.01.00 10.61.00 0.66Length = 8.009 ft 1 0.390 0.065 0.90 1.100 1.151.00 1.00 0.44 248.2 635.6 0.10 162.01.00 10.61.00 0.99Length = 0.5420 ft 1 0.033 0.065 0.90 1.100 1.151.00 1.00 0.06 31.5 962.4 0.10 162.01.00 10.61.00 0.99+D+L+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 Wood Beam LIC# : KW-06019339, Build:20.25.06.16 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:CJ1 SPS Engineering 15445 Ventura Blvd. #63 Sherman Oaks. CA 91403 818 747 7269 Project File: garnsey st.ec6 Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 0.61Length = 7.949 ft 1 0.966 0.149 1.00 1.100 1.151.00 1.00 1.12 629.2 651.0 0.25 180.01.00 26.91.00 0.60Length = 8.009 ft 1 0.973 0.149 1.00 1.100 1.151.00 1.00 1.12 630.0 647.5 0.25 180.01.00 26.91.00 0.99Length = 0.5420 ft 1 0.075 0.149 1.00 1.100 1.151.00 1.00 0.14 80.1 1,068.5 0.25 180.01.00 26.91.00 0.99+D+Lr+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.50Length = 7.949 ft 1 0.371 0.047 1.25 1.100 1.151.00 1.00 0.44 247.9 667.9 0.10 225.01.00 10.61.00 0.49Length = 8.009 ft 1 0.374 0.047 1.25 1.100 1.151.00 1.00 0.44 248.2 664.0 0.10 225.01.00 10.61.00 0.99Length = 0.5420 ft 1 0.024 0.047 1.25 1.100 1.151.00 1.00 0.06 31.5 1,333.3 0.10 225.01.00 10.61.00 0.99+D+S+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.54Length = 7.949 ft 1 0.374 0.051 1.15 1.100 1.151.00 1.00 0.44 247.9 662.7 0.10 207.01.00 10.61.00 0.53Length = 8.009 ft 1 0.377 0.051 1.15 1.100 1.151.00 1.00 0.44 248.2 658.9 0.10 207.01.00 10.61.00 0.99Length = 0.5420 ft 1 0.026 0.051 1.15 1.100 1.151.00 1.00 0.06 31.5 1,227.5 0.10 207.01.00 10.61.00 0.99+D+0.750Lr+0.750L+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.50Length = 7.949 ft 1 0.799 0.101 1.25 1.100 1.151.00 1.00 0.95 533.8 667.9 0.21 225.01.00 22.81.00 0.49Length = 8.009 ft 1 0.805 0.101 1.25 1.100 1.151.00 1.00 0.95 534.6 664.0 0.21 225.01.00 22.81.00 0.99Length = 0.5420 ft 1 0.051 0.101 1.25 1.100 1.151.00 1.00 0.12 67.9 1,333.3 0.21 225.01.00 22.81.00 0.99+D+0.750L+0.750S+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.54Length = 7.949 ft 1 0.806 0.110 1.15 1.100 1.151.00 1.00 0.95 533.8 662.7 0.21 207.01.00 22.81.00 0.53Length = 8.009 ft 1 0.811 0.110 1.15 1.100 1.151.00 1.00 0.95 534.6 658.9 0.21 207.01.00 22.81.00 0.99Length = 0.5420 ft 1 0.055 0.110 1.15 1.100 1.151.00 1.00 0.12 67.9 1,227.5 0.21 207.01.00 22.81.00 0.99+D+0.60W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.365 0.037 1.60 1.100 1.151.00 1.00 0.44 247.9 678.8 0.10 288.01.00 10.61.00 0.39Length = 8.009 ft 1 0.368 0.037 1.60 1.100 1.151.00 1.00 0.44 248.2 674.7 0.10 288.01.00 10.61.00 0.99Length = 0.5420 ft 1 0.019 0.037 1.60 1.100 1.151.00 1.00 0.06 31.5 1,702.0 0.10 288.01.00 10.61.00 0.99+D+0.750Lr+0.750L+0.450W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.786 0.079 1.60 1.100 1.151.00 1.00 0.95 533.8 678.8 0.21 288.01.00 22.81.00 0.39Length = 8.009 ft 1 0.792 0.079 1.60 1.100 1.151.00 1.00 0.95 534.6 674.7 0.21 288.01.00 22.81.00 0.99Length = 0.5420 ft 1 0.040 0.079 1.60 1.100 1.151.00 1.00 0.12 67.9 1,702.0 0.21 288.01.00 22.81.00 0.99+D+0.750L+0.750S+0.450W+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.786 0.079 1.60 1.100 1.151.00 1.00 0.95 533.8 678.8 0.21 288.01.00 22.81.00 0.39Length = 8.009 ft 1 0.792 0.079 1.60 1.100 1.151.00 1.00 0.95 534.6 674.7 0.21 288.01.00 22.81.00 0.99Length = 0.5420 ft 1 0.040 0.079 1.60 1.100 1.151.00 1.00 0.12 67.9 1,702.0 0.21 288.01.00 22.81.00 0.99+0.60D+0.60W+0.60H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.219 0.022 1.60 1.100 1.151.00 1.00 0.27 148.7 678.8 0.06 288.01.00 6.31.00 0.39Length = 8.009 ft 1 0.221 0.022 1.60 1.100 1.151.00 1.00 0.27 148.9 674.7 0.06 288.01.00 6.31.00 0.99Length = 0.5420 ft 1 0.011 0.022 1.60 1.100 1.151.00 1.00 0.03 18.9 1,702.0 0.06 288.01.00 6.31.00 0.99+D+0.70E+0.60H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.365 0.037 1.60 1.100 1.151.00 1.00 0.44 247.9 678.8 0.10 288.01.00 10.61.00 0.39Length = 8.009 ft 1 0.368 0.037 1.60 1.100 1.151.00 1.00 0.44 248.2 674.7 0.10 288.01.00 10.61.00 0.99Length = 0.5420 ft 1 0.019 0.037 1.60 1.100 1.151.00 1.00 0.06 31.5 1,702.0 0.10 288.01.00 10.61.00 0.99+D+0.750L+0.750S+0.5250E+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.786 0.079 1.60 1.100 1.151.00 1.00 0.95 533.8 678.8 0.21 288.01.00 22.81.00 0.39Length = 8.009 ft 1 0.792 0.079 1.60 1.100 1.151.00 1.00 0.95 534.6 674.7 0.21 288.01.00 22.81.00 0.99Length = 0.5420 ft 1 0.040 0.079 1.60 1.100 1.151.00 1.00 0.12 67.9 1,702.0 0.21 288.01.00 22.81.00 0.99+0.60D+0.70E+H 1.100 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 0.39Length = 7.949 ft 1 0.219 0.022 1.60 1.100 1.151.00 1.00 0.27 148.7 678.8 0.06 288.01.00 6.31.00 0.39Length = 8.009 ft 1 0.221 0.022 1.60 1.100 1.151.00 1.00 0.27 148.9 674.7 0.06 288.01.00 6.31.00 0.99Length = 0.5420 ft 1 0.011 0.022 1.60 1.100 1.151.00 1.00 0.03 18.9 1,702.0 0.06 288.01.00 6.31.00 . Wood Beam LIC# : KW-06019339, Build:20.25.06.16 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:CJ1 SPS Engineering 15445 Ventura Blvd. #63 Sherman Oaks. CA 91403 818 747 7269 Project File: garnsey st.ec6 LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+L+H1 0.4663 8.310 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.272 0.272 Max Upward from Load Combinations 0.272 0.272 Max Upward from Load Cases 0.165 0.165 +D+H 0.107 0.107 +D+L+H 0.272 0.272 +D+Lr+H 0.107 0.107 +D+S+H 0.107 0.107 +D+0.750Lr+0.750L+H 0.231 0.231 +D+0.750L+0.750S+H 0.231 0.231 +D+0.60W+H 0.107 0.107 +D+0.750Lr+0.750L+0.450W+H 0.231 0.231 +D+0.750L+0.750S+0.450W+H 0.231 0.231 +0.60D+0.60W+0.60H 0.064 0.064 +D+0.70E+0.60H 0.107 0.107 +D+0.750L+0.750S+0.5250E+H 0.231 0.231 +0.60D+0.70E+H 0.064 0.064 D Only 0.107 0.107 L Only 0.165 0.165 H Only Wood Beam LIC# : KW-06019339, Build:20.25.05.07 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:HDR1-3 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: garnsey st.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 4x6 Span = 4.0 ft 1 2 D(0.310) L(0.3550) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.310, L = 0.3550 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.819: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 2.000 ft 80.19 psi= = 1,105.00 psi 4x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 4x6 Maximum Shear Stress Ratio 0.445 : 1 3.547 ft= = 904.46 psi Maximum Deflection 1358 <360 725 Ratio =0 <240 Max Downward Transient Deflection 0.035 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.066 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 4.0 ft 1 0.424 0.231 0.90 1.300 1.001.00 1.00 0.62 421.6 994.5 0.48 162.01.00 37.41.00 1.00+D+L 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 4.0 ft 1 0.819 0.445 1.00 1.300 1.001.00 1.00 1.33 904.5 1,105.0 1.03 180.01.00 80.21.00 1.00+D+0.750L 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 4.0 ft 1 0.567 0.309 1.25 1.300 1.001.00 1.00 1.15 783.8 1,381.3 0.89 225.01.00 69.51.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 4.0 ft 1 0.143 0.078 1.60 1.300 1.001.00 1.00 0.37 253.0 1,768.0 0.29 288.01.00 22.41.00 . Wood Beam LIC# : KW-06019339, Build:20.25.05.07 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:HDR1-3 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: garnsey st.ec6 LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+L1 0.0662 2.015 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.330 1.330 Max Upward from Load Combinations 1.330 1.330 Max Upward from Load Cases 0.710 0.710 D Only 0.620 0.620 +D+L 1.330 1.330 +D+0.750L 1.153 1.153 +0.60D 0.372 0.372 L Only 0.710 0.710 Wood Beam LIC# : KW-06019339, Build:20.25.05.07 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:HDR4-6 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: garnsey st.ec6 CODE REFERENCES Calculations per NDS 2018, IBC 2021 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 4x8 Span = 6.0 ft 1 2 D(0.270) L(0.3150) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.270, L = 0.3150 k/ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.932: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 3.000 ft 83.30 psi= = 1,105.00 psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.463 : 1 0.000 ft= = 1,030.28 psi Maximum Deflection 1039 <360 559 Ratio =0 <240 Max Downward Transient Deflection 0.069 in 0 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.129 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 6.0 ft 1 0.478 0.237 0.90 1.300 1.001.00 1.00 1.22 475.5 994.5 0.65 162.01.00 38.41.00 1.00+D+L 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.932 0.463 1.00 1.300 1.001.00 1.00 2.63 1,030.3 1,105.0 1.41 180.01.00 83.31.00 1.00+D+0.750L 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.645 0.320 1.25 1.300 1.001.00 1.00 2.28 891.6 1,381.3 1.22 225.01.00 72.11.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.161 0.080 1.60 1.300 1.001.00 1.00 0.73 285.3 1,768.0 0.39 288.01.00 23.11.00 . Wood Beam LIC# : KW-06019339, Build:20.25.05.07 SPS Engineering (c) ENERCALC, LLC 1982-2025 DESCRIPTION:HDR4-6 SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks Ca, 91403 818 747 7269 Project File: garnsey st.ec6 LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+L1 0.1286 3.022 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.755 1.755 Max Upward from Load Combinations 1.755 1.755 Max Upward from Load Cases 0.945 0.945 D Only 0.810 0.810 +D+L 1.755 1.755 +D+0.750L 1.519 1.519 +0.60D 0.486 0.486 L Only 0.945 0.945 ASCE Hazards Report Address: 2049 S Garnsey St Santa Ana, California 92707 Standard:ASCE/SEI 7-16 Latitude:33.720743 Risk Category:II Longitude:-117.87473 Soil Class:D - Default (see Section 11.4.3) Elevation:0 ft (NAVD 88) Page 1 of 3https://ascehazardtool.org/Tue Nov 05 2024 SS : 1.285 S1 : 0.46 F a : 1.2 F v : N/A SMS : 1.541 SM1 : N/A SDS : 1.028 SD1 : N/A T L : 8 PGA : 0.545 PGA M : 0.654 F PGA : 1.2 Ie : 1 C v : 1.357 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Tue Nov 05 2024 Page 2 of 3https://ascehazardtool.org/Tue Nov 05 2024 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Tue Nov 05 2024 ASCE 7-16 Seismic Base Shear LIC# : KW-06019339, Build:20.24.10.30 SPS Engineering (c) ENERCALC, LLC 1982-2024 DESCRIPTION:Seismic Base Shear Analysis SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: Garnsey st.ec6 Risk Category ASCE 7-16, Page 4, Table 1.5-1 Calculations per ASCE 7-16 "II" : All Buildings and other structures except those listed as Category I, III, and IV Risk Category of Building or Other Structure : Seismic Importance Factor =1 ASCE 7-16, Page 5, Table 1.5-2 Specific Description: EARTHQUAKE USER DEFINED Ground Motion ASCE 7-16 11.4.2 Max. Ground Motions, 5% Damping : S =1.285 Longitude =0.000 deg West S Latitude =0.000 g, 0.2 sec response deg North S 0.4501 g, 1.0 sec response= Conforms to ASCE 7 Section 12.8.1.3: Regular structure with period of 0.5 s or less, SDS limited to max of 0.7*SDS or 1.0 for calculation of Cs. For the closest datapoint grid location . . . Site Class, Site Coeff. and Design Category Classification:ASCE 7-16 Table 20.3-1"D" : Shear Wave Velocity 600 to 1,200 ft/sec =D Site Coefficients Fa & Fv ASCE 7-16 Table 11.4-1 & 11.4-2 (using straight-line interpolation from table values) Fa =1.20 Fv =1.85 Maximum Considered Earthquake Acceleration ASCE 7-16 Eq. 11.4-1S = Fa * Ss 1.542=MS S = Fv * S1 =0.833M1 ASCE 7-16 Eq. 11.4-2 Design Spectral Acceleration ASCE 7-16 Eq. 11.4-3S = S * 2/3 =1.028DSMS =0.555 ASCE 7-16 Eq. 11.4-4S = S * 2/3D1M1 Seismic Design Category ASCE 7-16 Table 11.6-1 & -2=D (By Default per 11.4.3) Resisting System ASCE 7-16 Table 12.2-1 Basic Seismic Force Resisting System . . .Bearing Wall Systems 15.Light-frame (wood) walls sheathed w/wood structural panels rated for shear resistance. NOTE! See ASCE 7-16 for all applicable footnotes. Building height Limits :Response Modification Coefficient " R "=6.50 Category "A & B" Limit:No LimitSystem Overstrength Factor " Wo "=3.00 Category "C" Limit:No LimitDeflection Amplification Factor " Cd "=4.00 Category "D" Limit:Limit = 65 Category "E" Limit:Limit = 65 Category "F" Limit:Limit = 65 Lateral Force Procedure ASCE 7-16 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8 Use ASCE 12.8-7Determine Building Period Structure Type for Building Period Calculation :All Other Structural Systems " Ct " value 0.020= " x " value " hn " : Height from base to highest level =13.0 ft " Ta " Approximate fundemental period using Eq. 12.8-7 : 8.000"TL" : Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17 sec Ta = Ct * (hn ^ x) =0.137 0.75 sec = Building Period " Ta " Calculated from Approximate Method selected=0.137 ASCE 7-16 Seismic Base Shear LIC# : KW-06019339, Build:20.24.10.30 SPS Engineering (c) ENERCALC, LLC 1982-2024 DESCRIPTION:Seismic Base Shear Analysis SPS Engineering 15445 Ventura Blvd #63 Sherman Oaks CA, 91403 818 747 7269 Project File: Garnsey st.ec6 " Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1 S : Short Period Design Spectral Response 1.028 " R " : Response Modification Factor 6.50 " I " : Seismic Importance Factor =1 0.154From Eq. 12.8-2, Preliminary Cs = 0.624From Eq. 12.8-3 & 12.8-4 , Cs need not exceed = From Eq. 12.8-5 & 12.8-6, Cs not be less than =0.044 DS =Cs : Seismic Response Coefficient =0.1538User has selected ASCE 12.8.1.3 : Regular structure, Less than 5 Stories and with T <<= 0.5 sec, SO Ss <= 1.5 for Cs calculation = = Seismic Base Shear ASCE 7-16 Section 12.8.1 W ( see Sum Wi below ) =0.00 kCs =0.1538 from 12.8.1.1 Seismic Base Shear V = Cs * W =0.00 k Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3 " k " : hx exponent based on Ta =1.00 Table of building Weights by Floor Level... Wi : Weight Hi : Height (Wi * Hi^k)Cvx Fx=Cvx * V Sum Story Shear Sum Story MomentLevel # Sum Wi =0.00 k Total Base Shear =0.00 k Base Moment = 0.00 k-ftSum Wi * Hi = 0.0 k-ft Diaphragm Forces : Seismic Design Category "B" to "F"ASCE 7-16 12.10.1.1 Level #Wi Fi Fpx : MaxFpx : CalcdSum Fi Sum Wi Fpx Dsgn. ForceFpx : Min Wpx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weight at level of diaphragm and other structure elements attached to it. Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Lateral Force applied at the level. Sum Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sum of "Lat. Force" of current level plus all levels above 0.20 * S * I * WpxMIN Req'd Force @ Level . . . . . . . . . .DS DSMAX Req'd Force @ Level . . . . . . . . . .0.40 * S * I * Wpx Fpx : Design Force @ Level . . . . . . . . . .Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level LT i i r r r r r=1.3 5.40 psf Lateral Analysis: ENGINEERING 818 747 7269 | shant.sps@gmail.com Line A: LT s V =1080 (lbs)OM =576 (lbs) OM = v * H ν =72 (lb/ft)v = V/L RM =672 (lbs) RM = 14*Ls Line B: T s V =1080 (lbs)2nd ν =320 (lb/ft)RM =392 s Line 1: T s V =1080 (lbs)OM =617 (lbs) OM = v * H ν =77 (lb/ft)v = V/L RM =1568 (lbs) RM = 14*Ls Line 2: T s V =1080 (lbs)OM =1727 (lbs) OM = v * H ν =216 (lb/ft)v = V/L RM =560 (lbs) RM = 14*Ls r Roof Lateral Analysis: (1st Floor Walls) r ENGINEERING 818 747 7269 | shant.sps@gmail.com