Loading...
HomeMy WebLinkAbout1601 N Bristol St - Wall - Phase 1 - Plan65 NO PA R K I N G 15'-0" BLDG SETBACK 41'-3" 10'-2" 25'-0" 174'-6" STREET FRONTAGE 285'-6" PTO W. 17TH STREET 10'-1" 10 ' - 2 " 3' - 2 " 12'-0" 49'-6"16'-0"7'-6"11'-0"3'-6" 45 ' - 1 0 " 5' - 2 " 12 ' - 0 " 50 ' - 1 0 " 44'-5" 28'-0" 12 ' - 2 " 38'-0"4'-0"4'-0" 11'-0" 13 ' - 2 " 1' - 6 " 12 ' - 0 " 3' - 1 0 " 6' - 4 " 6' - 6 " 17 ' - 4 " 18'-1"19'-0" 8' - 7 " 25 ' - 1 1 " W. 1 7 T H S T R E E T 8'-0" 13 ' - 4 " 18 ' - 2 " 22'-0" 10'-0" 15'-0"15'-0" 8' - 6 " 0'-8" (E) MCDONALD'S ZONE: SP1 ZONE: SP1 ZONE: R1 R. 20' R. 20' R. 20' R. 20' R. 20' (N) "NO LEFT TURN" SIGN N1° 32' 07"E 92.24' L=27.89', R=185.00'D=8°38'11" L=12.41', R=72.00'D=9°52'46" S11° 24' 53"W 42.82' R. 20' 3'-0" LANDSCAPED SETBACK 4' LANDSCAPED SETBACK PROPERTY LINE (N) MONUMENT SIGN (UNDER SEPARATE PERMIT) (E) PORTION OF ISLAND TO BE REMOVED (E) PUBLIC SIDEWALK (N) CURB CUT (N) 8' CMU WALL TO BE INSTALLED AT PROPERTY LINE. SEE CIVIL DRAWINGS (ENGINEERING PLAN CHECK IN PROGRESS: 1601_BRISTOL_P0115118_2022_178030) (E) 6' CMU WALL (E) CONCRETE CURB PROPERTY LINE (E) LANDSCAPE AREA (E) LANDSCAPE AREA (E) LANDSCAPE AREA (E) 8' CMU WALL TO BE REMOVED 10' LANDSCAPED SETBACK (E) PUBLIC SIDEWALK (E) FIRE HYDRANT S1° 32' 05"W174.36' N8 9 ° 1 1 ' 5 9 " W 11 0 . 6 9 ' S8 9 ° 1 1 ' 5 6 " E 9 9 . 5 7 ' (E) STREET LIGHT 24" VEHICLE OVERHANG COVERED TRASH ENCLOSURE UNDER SEPARATE PERMIT 3' LANDSCAPE SETBACK NEW LANDSCAPING PROPERTY LINE HERRINGBONE STAMPED AND COLORED CONCRETE R. 24'R. 20' R. 20' 203'-7" TO P/UWDW. 80'-1" TO MENU BD. 15' SIGHT TRIANGLE PER EXHIBIT 'A' AT DRIVEWAY 15' SIGHT TRIANGLE PER EXHIBIT 'A' AT DRIVEWAY DN. PROPERTY LINE (E) 5' CMU WALL AT PROPERTY LINE 40' X 16' STAGING AREA. DRIVEWAY AND STAGING AREA TO WITHSTAND 60,000 LBS. (2) 3 YARD DUMPSTERS 64 GALLON TRASH BIN GREASE INTERCEPTOR BY OTHERS 10' LANDSCAPED SETBACK (4) BICYCLE PARKING SPACES N. BRISTOL STREET 2'-0" 4'-0" (E) STREET LIGHT 18'-0" 17'-8" HEIGHT CLEARANCE BAR UNDER SEPARATE TENANT PERMIT PREVIEW MENU BOARD UNDER SEPARATE TENANT PERMIT LANDSCAPED AREA DRIVE THRU ORDER/ MENU BOARD UNDER SEPARATE TENANT PERMIT (N) SPEAKER POST AND CANOPY WITH DETECTOR LOOP UNDER SEPARATE TENANT PERMIT EN T R Y ENTRY NO PARKING SIGN 8 AS2.1 SIGNAGE UNDER SEPARATE TENANT PERMIT DRIVE THRU CONCRETE PAVEMENT UNDER TENANT PERMIT END OF PAVING UNDER THIS SCOPE ALL FLATWORK & PATIO IMPROVEMENTS UNDER SEPARATE TENANT PERMIT (N) ELECTRICAL SWITCHGEAR (N) LIGHT POLE, TYP (N) LIGHT POLE, TYP (E) POWER POLE WITH (N) POLE-MOUNTED TRANSFORMER HANDRAIL UNDER SEPARATE TENANT PERMIT 4'-0" DN DN 2'-0"4'-6" 4'-7" 4' - 0 " 5'-2" 4' - 0 " 10'-2" 4'-0" BUILDING UNDER SEPARATE PERMIT APPROX. 1,753 GROSS S.F. 1,634 NET S.F. ACCESSIBLE PATH OF TRAVEL ALL SITE CURBING, PAVING, AND WET UTILITIES PER CIVIL DRAWINGS (BEING REVIEWED BY ENGINEERING). ACCESSIBLE PATH OF TRAVEL NOTE: SEE CIVIL FOR GRADING/DRAINAGE, SITE UTILITIES (SEWER, WATER, GREASE INTERCEPTOR), SITE CURBS & SITE AC PAVING. (ENGINEERING PLAN CHECK IN PROGRESS: 1601_BRISTOL_P0115118_2022_178030) SI T E P L A N AS1.1SITE PLAN SCALE 81" = 10'-0" N GENERAL NOTES 1.THIS IS A CONCEPTUAL SITE PLAN. UNLESS OTHERWISE NOTED, ALL ELEMENTS AND CONDITIONS ARE EXISTING. 2.GENERAL (E) SURFACE DRAINAGE PATTERN, INCLUDING (E) ROOF DRAINAGE LOAD TRANSFERRED TO GROUND LEVEL, IS TO REMAIN AS IS. 3.VEHICULAR ACCESS DRIVES MUST BE PROVIDED AND MAINTAINED SERVICEABLE THROUGHOUT CONSTRUCTION. 4.CONTRACTOR SHALL ERECT AND MAINTAIN BARRICADES, WARNING SIGNS AND TRAFFIC CONES PER LOCAL REQUIREMENTS. ACCESS TO DRIVEWAYS TO BE MAINTAINED AT ALL TIMES. ALL TRAFFIC CONTROL MEASURES SHALL BE APPROVED AND IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITY. 5.ALL MATERIALS AND WORKMANSHIP FOR PUBLIC FACILITIES TO CONFORM TO CITY STANDARD CONSTRUCTION SPECIFICATIONS. 6.CONTRACTOR SHALL SWEEP ENTIRE SITE OR PORTIONS OF SITE TO BE USED BY THE PUBLIC AND SURROUNDING RIGHT-OF-WAY AREA OF THE STREET PRIOR TO USE BY THE GENERAL PUBLIC, IF ACCESSIBLE TO THE PUBLIC. 7.THE SITE SHALL BE KEPT FREE OF FIRE HAZARDS FROM THE START OF CONSTRUCTION TO FINAL INSPECTION. 8.THE G.C. SHALL IMPLEMENT A BEST MANAGEMENT PRACTICE STORMWATER FOR ALL ACTIVITIES PER CAL GREEN REQUIREMENTS. 9.THE G.C. IS RESPONSIBLE TO VERIFY ALL UNDERGROUND UTILITIES PRIOR TO PERFORMING EXTERIOR WORK. CALL 811 BEFORE DIGGING. 10.G.C. TO VERIFY ANY ABRUPT CHANGE IN LEVEL EXCEEDING 1/2" EXISTING CONCRETE SLAB/ASPHALT TRANSITION FROM ENTRY TO PUBLIC WAY/ ACCESS. G.C. TO PROVIDE CLEAR PATH OF TRAVEL, PER SECTION 11B-303. 11.SITE & PARKING ARE EXISTING TO REMAIN UNCHANGED, UNLESS OTHERWISE NOTED. 12.BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, CONTRASTING WITH THEIR BACKGROUND. NUMBERS SHALL BE A MINIMUM OF 6 INCHES HIGH WITH A MINIMUM STROKE OF .5 INCHES. WHERE ACCESS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. (CFC 505.1) 13.THE G.C. IS RESPONSIBLE TO FIELD VERIFY AND LOCATE ALL WET AND DRY UTILITIES CONNECTION POINTS PRIOR TO ANY DEMOLITION OR CONSTRUCTION. (I.E. GAS, WATER AND SEWER, CLEAN OUTS, ETC. LEGEND ACCESSIBLE PATH OF TRAVEL PATH OF TRAVEL NOTE: NO ABRUPT CHANGES OF ELEVATION ALONG THE PATH OF TRAVEL SHOWN. THE SLOPE AND CROSS SLOPE ALONG THE PATH OF TRAVEL SHALL NOT EXCEED 5% AND 2% RESPECTIVELY. INSPECTOR TO VERIFY. 1 AS2.1 S H E E T N U M B E R A2157 Pl o t t e d : 5/ 2 / 2 0 2 5 8 : 5 1 A M ( la u r e ) F i l e : 04 _ a 2 1 5 7 _ a s 1 . 1 _ s i t e p l a n . d w g PROJECT NUMBER 2025.05.02 DATE R E V I S I O N S S T A M P SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED. P R O J E C T L O C A T I O N C O N S U L T A N T S H E E T T I T L E C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL. 16 0 1 N B R I S T O L S T , SA N T A A N A , C A 9 2 7 0 6 9431 HAVEN AVENUE, SUITE 212 RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com WEST COAST | CENTRAL | EAST COAST SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED. DATE SIGNED: 05/02/2025 BRISTOL CENTER PROPERTIES LLC 714 S PLYMOUTH BLVD LOS ANGELES, CA 90005 AMIR HOURIANI aihouriani@gmail.com SI T E D E V E L O P M E N T TE STA RNFOAOCFLI AI LICENSED ARCHITECTWILLIAA.AMOR DATE 8/31/2025 M C - 24421 RENEWAL 1 1/31/25 PLAN CHECK CORRECTIONS 2 4/1/25 PLAN CHECK CORRECTIONS 3 5/2/25 PLAN CHECK CORRECTIONS 10 AS2.1 20 AS2.1 3 Bldg #101124645 APPROVALS:PLNG - F. Arias BLDG - W. Lee PUBLIC WORKS - Y. Soto BEFOREYOUDIG TOLLFREE DIAL 1-800-227-2600 BehroozSarlak 7/29/2025 EXHIBIT FOR EAST PROPERTY LINE WALL ONLY BEFORE YOU DIG TOLL FREE DIAL 1-800-227-2600 PH (951) 736-0200 CL (949) 370-7099 PERRIS, CA 92570 20730 KNOB PLACE CornerstoneLand Surveying Inc. PH (951) 736-0200 CL (949) 370-7099 PERRIS, CA 92570 20730 KNOB PLACE CornerstoneLand Surveying Inc. BEFORE YOU DIG TOLL FREE DIAL 1-800-227-2600 PH (951) 736-0200 CL (949) 370-7099 PERRIS, CA 92570 20730 KNOB PLACE CornerstoneLand Surveying Inc. PH (951) 736-0200 CL (949) 370-7099 PERRIS, CA 92570 20730 KNOB PLACE CornerstoneLand Surveying Inc. CITY OF SAP TA ANA Planning and Building Agency PROPOSED RETAINING BLOCK WALL FOR 1601 BRISTOL ST. SANTA ANA, CA STRUCTURAL CALCULATIONS Contents Wind Load calculations Retain Pro Calculations & Diagrams Typical Wall Detail Owner Southwest Group Properties, LLC 714 S. Plymouth Blvd. Los Angeles, CA 90005 Prepared by: Cornerstone Surveying , Inc. 20730 Knob Place Perris, CA 92570 O (951) 736-0200 / M (949) 370-7099 stefan@coronasurveyor.com 04 August 2025 /'E-F�MEll IT �kSSUANCE 6 cs���� Ma to ID: Date. °%�, -1v PROJECT: LOCATION: DESIGNER: CMU WALL - WIND LOAD CALCULATION DESCRIPTION:5'-0" Exposed Ht (max) Wall total Height =8'-0" max 1. Design Data: Solidity factor for Wall = 100% Wall Geometry: Tributary Width of wall, B:1.00 ft. Width of wall in the direction under consideration, L:174.4 ft. Wall Exposed Height, H:5.00 ft. Wind Design Parameters: F = qh G Cf As (ASCE 7-22 Sec. 29.3-1) Pw = qh G Cf (ASCE 7-22 Sec. 26.7.3) ASD factor:0.6 Exposure Category:C Where: F = Design wind force, = Pw As (lbs.)(ASCE 7-22 Eq. 29.3-1) qh = velocity pressure evaluated at height, h (ASCE 7-22 Sec. 29.3.2) Cf = Net force coefficient (ASCE 7-22 Fig. 29.4-1) As = Gross area of the solid freestanding wall (ft 2 ) G = Gust Factor (ASCE 7-22 Sec. 26.11) Pw = Design Wind Pressure, = qh G Cf (psf ) Calculate Design Wind Pressure, Pw: Net Force Coefficient, Cf:(ASCE 7-22 Sec. 29.3) Case:A & B (Fig. 29.3-1) height of free standing wall or fence, s: (Exposed height)5.00 ft Height from top of wall to ground surface, h:7.33 ft Clearance ratio, s/h: 5.00 7.33 Aspect ratio of the fence, L/s: 174.40 5.00 By Interpolation, Cf: 1.55 Gust Factor Coefficient, G:(ASCE 7-22 Sec. 26.11) Check if Structure is Flexible or Rigid: Calculate approx. natural frequency, na: Mean gate height (exposed height): (use full height H)5.00 ft 22.2 22.2 (Eq. 26.11-2) 3.624 na= 6.126 > 1 Hz Rigid Frame System 1+1.7gQ Iz Q (eq.26.11-6) 1+1.7gv Iz From: z= equivalent height of structure = 0.6h =34.88 DESIGN CALCULATION na= = G=0.925 RET.WALL_Better Buzz Bristol Santa Ana,CA GATS&M =0.68 ℎ. PROJECT: LOCATION: DESIGNER: DESIGN CALCULATION RET.WALL_Better Buzz Bristol Santa Ana,CA GATS&M z = 3.000 < Zmin: 15.0 ft use z = 15 ft c = 0.2 (Turbulence Intensity factor)(Table 26.11-1) Intensity of turbulence at equivalent height z, Iz: (Eq. 26.11-7) Iz = 0.228 3.4 (Sec. 26.11.4) Integral length scale of turbulence at equivalent height z, Lz: (Eq. 26.11-9) I =500 ft (equivalent length scale factor) (Table 26.11-1) z =15 ft (equivalent height of structure) ε =0.2 (ratio of Asolid to Agross - Free standing structures) (Table 26.11-1) B+H =6.00 ft Solving Lz: Lz = 428 Background Response Coefficient, Q: (Eq. 26.11-8) =0.979 2.2910 2.3183 G = 0.914 Q = G = 0.925 *1 + 1.7gQ Iz Q 1 + 1.7gv Iz = 0.925 𝐼𝑧= 𝑐 (33 𝑧)⁄⁄ 𝒈𝑸 𝒂𝒏𝒅 𝒈𝒗: 𝐿𝑧=𝐼 (𝑧33)⁄ [1 1 + 0.63 𝑏 +ℎ 𝐿𝑧 .]. PROJECT: LOCATION: DESIGNER: DESIGN CALCULATION RET.WALL_Better Buzz Bristol Santa Ana,CA GATS&M Velocity pressure, qh:(ASCE 7-22 Sec. 29.10) qh = 0.00256 Kz Kzt Kd V2 (psf)(Eq. 26.10-1) Wind Directionality, Kd: (Per Section 26.6, Kd shall only be included when the load combinations in Sec. 2.3 and 2.4 are used in the design) kd = 0.85 (ASCE 7-22 Table 26.6-1) Velocity Pressure Exposure Coefficient, Kz:(ASCE 7-22 Table 26.10-1) Nominal height of the atmospheric boundary layer, Zg: 900 ft z = height above ground level:(h < 15 ft, use 15ft. Min.)15 ft 3 sec. gust-speed power law exponent, α: 9.5 kz = 0.849 Topographic Factor, Kzt: Kzt = 1 + (k1 k2 k3)2 (ASCE 7-22 Eq. 26.8-1) Kzt = 1.0 (site conditions do not meet Sec 26.8.1) Basic Wind speed, V (ASCE 7-22 Figs. 26.5-1A through 26.5-2D) Risk Category:II (Table 1.5-1) V =95 mph (Fig. 26.5-1B) qh = 0.00256 Kz Kzt Kd Ke V2 =19.6126 (note: Kd not considered) qh = 19.61 psf Design Wind Pressure, Pw: Pw = qh G Cf x (ASD Factor) Pw = (19.61) x (0.914) x (1.55) x 0.6 = 16.67 psf say: = 17.00 psf Pw =17.00 psf (ASD) 𝐾𝑧= 2.01 [𝑧𝑧𝑔] ⁄ ASCE Hazards Report Address: 1601 N Bristol St Santa Ana, California 92706 Standard:ASCE/SEI 7-22 Latitude:33.758813 Risk Category:II Longitude:-117.88464 Soil Class:Default Elevation:108.05144117746228 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 102 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 133 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Sun Aug 03 2025 Page 1 of 3https://ascehazardtool.org/Sun Aug 03 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service Level wind speeds, all other wind speeds are Ultimate wind speeds. Site is not in a hurricane-prone region as defined in ASCE/SEI 7-22 Section 26.2. Page 2 of 3https://ascehazardtool.org/Sun Aug 03 2025 Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall Code References Calculations per IBC 2012 1807.3, CBC 2013, ASCE 7-10 3.00 5.00 0.00 8.00 1,200.0 45.0 0.0 250.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water table above =ft = = 110.00=pcf = Soil Density, Heel = Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 110.00 pcf Footing||Soil Friction =0.400 Soil height to ignore for passive pressure =12.00 in Equivalent Fluid Pressure Method bottom of footing Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf17.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Spread Footing Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall Design Summary Wall Stability Ratios Overturning =5.50 Global Stability =4.29 OK Sliding =2.65 OK Total Bearing Load =2,587 lbs ...resultant ecc.=3.53 in Eccentricity within middle third Soil Pressure @ Toe =657 psf OK Soil Pressure @ Heel =315 psf OK Allowable =1,200 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =920 psf ACI Factored @ Heel =440 psf Footing Shear @ Toe =0.0 psi OK Footing Shear @ Heel =0.3 psi OK Allowable =94.9 psi Sliding Calcs Lateral Sliding Force =507.5 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 972.0 375.0 == 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type = Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Masonry Thickness =8.00 Rebar Size =#5 Rebar Spacing =16.00 Rebar Placed at =Center Design Data fb/FB + fa/Fa =0.517 Total Force @ Section =287.5lbs Moment....Actual =670.0ft-# Moment.....Allowable =1,294.8 =6.0psi Shear.....Allowable =43.6psi Wall Weight =0.0psf Rebar Depth 'd'=3.81in Masonry Data f'm =1,500psiFs=psi 20,000 Solid Grouting =No Modular Ratio 'n'=21.48 Equiv. Solid Thick.=5.48in Concrete Data f'c =psi Fy = Masonry Design Method ASD= Load Factors Building Code Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.600 Seismic, E 1.000 psi Service Level =lbsStrength Level Service Level Strength Level =ft-# Service Level Strength Level =psi Design Method =ASD SD SD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=47.54in2 Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall 0.00 5.00 16.00 Footing Torsion, Tu = = ft-lbs0.00 Min. As % Footing Allow. Torsion, ij Tn 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =4,000 psi Toe Width =ft Heel Width = Footing Thickness =in 5.00= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete Density Fy =60,000 psi Footing Design Results Key: = No key defined Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:Flush toe condition. No reinforcing required. #4@ 6.94 in, #5@ 10.76 in, #6@ 15.27 in, #7@ 20.83 in, #8@ 27.43 in, #9@ 34.72 in, #10@ 44.09 in =None Spec'd = = = = = 920 0 0 0 0.00 0.00 Heel: 440 5,437 6,431 994 0.33 94.87 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 10.76 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing = Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 1.73 0.35 #4@ 6.94 in #5@ 10.76 in #6@ 15.28 in in2 in2 /ft If two layers of horizontal bars: #4@ 13.89 in #5@ 21.53 in #6@ 30.56 in supplemental design for footing torsion. ij Mn 20,898= Flush toe condition. No reinforcing required. OK - Flush Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = 85.0 6.83 580.8 = = = = = Stem Weight(s) =Earth @ Stem Transitions =Footing Weight = 1,000.0 2.50 2,500.0 Key Weight = Added Lateral Load lbs =1,191.1 Vert. Component Total = 2,430.0 6,551.7 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =507.5 O.T.M. = Resisting/Overturning Ratio =5.50 Vertical Loads used for Soil Pressure =2,586.9 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,430.0 2.83 2.83 4,051.7 4,051.7 Water Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 422.5 1.44 610.3 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.029 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Calculated Rebar Stress, fs = 10349.06 psi Lap Splice length for #5 bar specified in this stem design segment (25.4.2.3a) =25.00 in Development length for #5 bar specified in this stem design segment =12.94 in Hooked embedment length into footing for #5 bar specified in this stem design segment =6.00 in As Provided =0.2325 in2/ft As Required =0.1184 in2/ft Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall Cantilevered Retaining Wall LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 DESCRIPTION:8 ft high wall_L Type Ftg Project File: Bristol_better buzz.ec6 Project Title:Better Buzz_Bristol Engineer: Project ID: Project Descr:Retaining Wall ADJACENT PROPERTY ONSITE PROPERTY LINE 811 !� . --2" HIGH MORTAR 0 w STD. 90° BEND ■�f111» — TOP OF WALL (TW). SEE ELEVATION PER PLAN ON SHEET 2 & PROFILE ON SHEET 7. 811 X 611 X 1611 COLOR AND TEXTURE PER ARCH SPECS. #5 @ 16" O.C. @ CENTER (GROUT ALL CELLS WITH REBAR) #5 CONTINUOUS @ 2411 O.C. 5 1 -011 FINISH GRADE CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANCE Master ID: Date: #5 @ 1611L O.C. (GROUT ALL CELLS WITH REBAR) TOP OF FOOTING (TF). SEE ELEVATION PER PLAN ON SHEET 2 AND PROFILE ON SHEET 7. 0 #5 @ 12" TOP & BOTTOM re) J U l.LR �11 n1 n !�j 4—#5 CONT. — TOP & BOTTOM M 1211 TYP WALL SECTION NTS YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs