HomeMy WebLinkAbout2360 N Tustin Ave - REV 1 - PlanS/S KICK PLATE ON 'PUSH' SIDE (BOTH SIDES OF RESTROOM DOORS) 10 " SOLID CORE WOODB 34 " - 4 4 " INSULATED IMPACT DOORC NON-INSULATED IMPACT DOORD SERVICE GATEE 12 " ·AT ALL DRY STORAGE ROOMS ·STAINLESS STEEL WRAPPED FRAME MODEL 200 VINYL DOOR BY CHASE INDUSTRIES, INC. ·FINISH TO BE BLACK, U.N.O. ·DOOR PROVIDED AND INSTALLED BY G.C. ·DOOR FRAME PROVIDED AND INSTALLED BY G.C. ·STAINLESS STEEL WRAPPED FRAME ·SINGE OR PAIR, AS SCHEDULED ·SINGLE PANE WINDOWS ·DOOR HARDWARE SHALL BE LEVER OR PUSH TYPE. MOUNTED 34" TO 44" ABOVE FINISH FLOOR AND BE OPERABLE WITH MAX. EFFORT OF 8.5 LBS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR DOORS ·THE LOWER 10" OF THE DOOR SHALL BE OF A SMOOTH UNINTERRUPTED SURFACE THAT ALLOWS DOORS TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CAUSING A TRAP OR HAZARD, EXCEPT AT AUTOMATIC OR SLIDING DOORS. ·EXISTING FRAME TO REMAIN, TYP. STYLE OF DOOR TO MATCH. NEW FINISH SHALL BE PLASTIC LAMINATE: FORMICA, #5489-NT ESPRESSO PEAR. VERIFY WITH SBM REP TO RE-USE AND/OR REPLACE EXISTING HARDWARE. ·AT ALL COOLER/FREEZER ROOMS ·STAINLESS STEEL WRAPPED FRAME MODEL 200 VINYL DOOR BY CHASE INDUSTRIES, INC. ·FINISH TO BE BLACK, U.N.O. ·DOOR PROVIDED AND INSTALLED BY G.C. ·DOOR FRAME PROVIDED AND INSTALLED BY G.C. ·STAINLESS STEEL WRAPPED FRAME ·SINGLE OR PAIR, AS SCHEDULED ·DUAL PANE WINDOWS DUAL SWING IMPACT DOORF ·ROLL-UP, EXISTING U.N.O. NEW INDUSTRIAL IMPACT DOORS EXTERIOR VIEW ·DUAL PANE WINDOW AT ALL COOLER/FREEZER ROOMS ·SINGLE PANE WINDOW AT ALL STORAGE ROOMS DOOR TYPES NOTE: ALL FRAMES TO MATCH EXISTING FINISH. HOLLOW METAL DOORG 34 " - 4 4 " ·DOOR HARDWARE SHALL BE LEVER OR PUSH TYPE. MOUNTED 34" TO 44" ABOVE FINISH FLOOR AND BE OPERABLE WITH MAX. EFFORT OF 8.5 LBS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR DOORS ·EXISTING FRAME TO REMAIN, TYP. STYLE OF DOOR TO MATCH. PAINT P-1 WINDOW TYPES NOTE: ALL FRAMES TO MATCH EXISTING FINISH. WINDOW GLAZING TO BE SAFETY GLAZING AND DOUBLE PANE CLEAR FLOAT GLASS. U-FACTOR: 0.41 - SHGC: 0.26 - VT: 0.46 VERIFY ALL (E) CONDITIONS PRIOR TO ALL WORK. 15'-112" 15'-512" (FIELD VERIFY) 14 ' - 0 " ( F I E L D V E R I F Y ) 4' - 0 " 6' - 1 0 " 3' - 2 " BL A C K O U T T I N T EN T I R E S T O R E F R O N T 3' - 7 " 3' - 7 " 3' - 7 " 15'-112" 15'-512" (FIELD VERIFY) 14 ' - 0 " ( F I E L D V E R I F Y ) 4' - 0 " 6' - 1 0 " 3' - 2 " BL A C K O U T T I N T EN T I R E S T O R E F R O N T STOREFRONT GLASS DOORA STOREFRONT GLASS DOORB PRINTED: 25 Jul 2025 I: \ M Y D R I V E \ P R O D U C T I O N C L O U D \ D R A W I N G \ S T A T E R B R O S \ 8 1 6 6 - G R O U P 7 \ 8 1 6 6 . 8 - S B 4 0 S A N T A C L A R A ( S A N T A A N A ) \ A R C H I T E C T U R E \ 8 1 6 6 . 8 - A 7 . 0 0 . D W G Fr i d a y , J u l y 2 5 , 2 0 2 5 1 : 5 3 : 1 8 P M 8166.8 GG SHEETOF SH E E T T I T L E JO B N A M E JOB SHEET NO. DA T E DR A W N B Y NO . DA T E CH E C K E D B Y IN AC C E P T I N G AN D UT I L I Z I N G AN Y DR A W I N G S , RE P O R T S AN D DA T A ON AN Y FO R M OF EL E C T R O N I C ME D I A GE N E R A T E D AN D FU R N I S H E D BY RM C A , TH E CL I E N T AG R E E S TH A T AL L SU C H EL E C T R O N I C FI L E S AR E IN S T R U M E N T S OF SE R V I C E OF RM C A , WH O SH A L L BE DE E M E D TH E AU T H O R , AN D SH A L L RE T A I N AL L CO M M O N LA W , ST A T U T O R Y LA W AN D OT H E R RI G H T S , IN C L U D I N G C O P Y R I G H T S . TH E CL I E N T AG R E E S NO T TO RE U S E TH E S E EL E C T R O N I C FI L E S , IN WH O L E OR IN PA R T , IN C L U D I N G DE T A I L S , FO R AN Y PU R P O S E OT H E R TH A N FO R TH I S PR O J E C T . TH E CL I E N T AG R E E S NO T TO TR A N S F E R TH E S E EL E C T R O N I C FI L E S TO OT H E R S WI T H O U T TH E PR I O R WR I T T E N CO N S E N T OF RM C A . TH E CL I E N T FU R T H E R AG R E E S TO WA I V E AL L CL A I M S AG A I N S T RM C A RE S U L T I N G IN AN Y WA Y FR O M AN Y UN A U T H O R I Z E D CH A N G E S TO OR RE U S E OF TH E EL E C T R O N I C FI L E S FO R AN Y OT H E R PR O J E C T BY AN Y O N E OT H E R TH A N RM C A AR C H I T E C T U R E DE S I G N P L A N N I N G , I N C . NO . DA T E S T A T E R B R O S . D E V E L O P M E N T , I N C . 3 0 1 S T I P P E C A N O E A V E N U E S A N B E R N A R D I N O , C A 9 2 4 0 8 JL RE V I S I O N RE V I S I O N 08 / 1 8 / 2 0 2 4 L ICENSED A RCHITECT STATE OF CA L IFORNIA C-41383 12/31/25 J E SUS ANT ONIO LA RA RENEW A L DATE ST A T E R B R O S . # 4 0 S A N T A C L A R A 23 6 0 N T U S T I N A V E . , SA N T A A N A , C A L I F O R N I A 9 2 7 0 5 1 TRANSVERT MULLION SCALE: 3" = 1'-0" 412" 13 4" U.S. ALUM - JS455 GLAZING, SINGLE PANE, LOW E 2 STOREFRONT JAMB SCALE: 3" = 1'-0" STOREFRONT SYSTEM (E) CMU WALL SEALANT W/ BACKER ROD EA. SIDE (N) TITAN HD SCREW ANCHOR 14" @ 16", ESR # 2713 (E) CONC. STOREFRONT SYSTEM SEALANT W/ BACKER ROD EA. SIDE SHIM 3 STOREFRONT SILL SCALE: 3" = 1'-0" (E) SIDEWALK (N) TITEN HD SCREW ANCHOR 14" @ 16", ESR # 2713 SILICON SEALANT, BOTH SIDES (N) STOREFRONT (E) SOFFIT EXTERIOR INTERIOR (N) TITEN HD, SCREW ANCHOR 14" @ 16", ESR # 2713 4 STOREFRONT HEADER SCALE: 1 1/2" = 1'-0" DOOR GENERAL NOTES 1.HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES THAT ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. (11B-309.4). OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MINIMUM AND 44" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND (11B-404.2.7) 2.MAXIMUM FORCE TO FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS: EXTERIOR OR INTERIOR HINGED DOORS SHALL NOT EXCEED FIVE POUNDS. MAXIMUM. FOR FIRE DOORS, NOT TO EXCEED 15 POUNDS. (11B-404.2.9). 3.ALL DOORS HARDWARE SHALL BE IN WORKING CONDITION AND REPAIR HARDWARE & DOOR AS REQUIRED. 4.DOOR/GATE CLOSER SHALL BE ADJUSTED SO THAT FROM OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR/GATE TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECOND MINIMUM. (11B-404.2.8.1) 5.VISION PANELS IN DOOR/GATES AND SIDE LIGHTS: AT LEAST ONE PANEL SHALL HAVE BOTTOM LOCATED NOT MORE THAN 43" ABOVE THE FLOOR. EXITING REQUIREMENTS ACCESSIBLE REQUIREMENTS BUILDIING DEPARTMENT NOTES: ADDITIONAL REQUIREMENTS 1.WEATHERSTRIP ALL EXTERIOR DOORS WITH GASKET-TYPE WEATHERSTRIPPING 2.ALL HARDWARE SHALL BE THE LEVER TYPE WHERE REQUIRED BY 2022 CBC 3.BOTTOM 10" OF DOOR ON PUSH SIDES TO BE SMOOTH 4.PROVIDE A READILY VISIBLE AND DURABLE SIGN WITH A MINIMUM 1" LETTERS ON OR NEAR THE EXIT DOORS READING; 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS' 5.SELF CLOSING COOLER/FREEZER DOOR WITH 36" HIGH ALUM. KICK PALATE AT BOTH SIDE TO BE PROVIDED / INSTALLED BY COOLER/FREEZER MANUFACTURE 60 " MI N . 18" CLR. INT. MIN. 24" CLR. EXT. MIN. 12" CLR. 36" MIN. 48 " MI N . NOTE: 1.EXTERIOR DOOR LANDINGS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60" SQUARE AT A DOOR THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48" WIDE BY 44" DEEP AT A DOOR THAT SWINGS AWAY FROM THE WALK. 2.LEVEL AREA OF EXTERIOR WALKS SHALL EXTEND 24" TO THE SIDE OF THE STRIKE EDGE OF A DOOR THAT SWINGS TOWARD THE WALK. 3.DOOR ADDITIONAL INFORMATION, RE: DA-1, DA-2, DA-3 & DA-4 5 DOOR CLEARANCE SCALE: 1/4" = 1'-0" NO STOP AT CASED OPENING DOOR WOOD FRAMING, RE: STRUCT. PLANS VARIES WOOD STUD WALL, RE: A1.1 CONT. SEALANT, EACH SIDE. 6 JAMB SCALE: 1 1/2" = 1'-0" WOOD STUD WALL, RE:A1.1 NO STOP AT CASED OPENING DOOR VARIES CONT. SEALANT, EACH SIDE 7 HEADER SCALE: 1 1/2" = 1'-0" WOOD FRAMING RE:STRUCT. PLANS FRAME 1 WINDOW NO. WINDOW TYPE REMARKSWINDOW SIZE WIDTH HEIGHT WINDOW SCHEDULE -H.M. - HOLLOW METAL S/S - STAINLESS STEEL B 15'-5 1/2" V.I.F.ALUMINUM14'-0" V.I.F.FIXED, NON-OPERABLE TEMPERED GLAZING TRAFFIC IMPACT DOOR VARIES CONT. CASING BEAD & SEALANT BOTH SIDES 5 8" GYP. BD. OVER WOOD STUD, RE: A1.1 2" DO O R OP E N I N G 1 4"1 4" S.S. FRAME 14" PLATE FULL HT. AT JAMB WELDED INSIDE FRAME BOTH JAMBS 12 IMPACT DOOR DETALS SCALE: 1 1/2" = 1'-0" JAMB AT HINGE 2"DOOR OPENING 4"X3" 12"X14"X3" 12" LEG STL. ANGLES WELDED TO 4"X4" STL. JAMBS M.B. TO CONC. W/ 5 8" Ø REDHEAD ANCHOR 4"X2" STL. CHANNEL BET. JAMBS ABOVE CEILING 16" GA. S.S. CLADDING HEAD 2" DO O R OP E N I N G 18 GA. STAINLESS STL. CLADDING JAMB/HEAD 1.EXTERIOR SWINGING EXIT DOORS - LOCKING HARDWARE SHALL BE OPERATED FROM THE INSIDE AND A DEVICE NOT PROHIBITED BY C.B.C CHAPTER 10 2.MAIN SALES AREA EXIT DOORS SHALL BE PROVIDED WITH A SIGN WITH 1" HIGH LETTERS ON CONTRASTING BACKGROUND AT DOOR TRANSOM THAT READS: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." 3.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND OPERATE IN THE DIRECTION OF EGRESS. 4.ILLUMINATED EXIT SIGNS AT EACH EXIT TO HAVE GREEN LETTERS A MINIMUM OF 6" HIGH, RE: ELECTRICAL PLANS 5.EXIT ILLUMINATION SHALL BE SUPPLIED AS REQUIRED BY C.B.C. SECTION 1008 ALARM LOCK AND PANIC HARDWARE SHALL COMPLY WITH FIRE MARSHALS REQUIREMENTS. 6.ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM THE OUTSIDE WHEN THE DOOR IS CLOSED SHALL HAVE NONREMOVABLE HINGE PINS. IN ADDITION, THEY SHALL HAVE A MINIMUM 1/4" DIAMETER STL. JAMB STUD WITH 1/4" MINIMUM PROJECTIONS UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE HINGE PINS ARE REMOVED. 7. A FLOOR OR LANDING NOT MORE THAN 3/4" BELOW THE THRESHOLD SHALL BE PROVIDED 4 ON BOTH SIDES OF ALL EXIT DOORS AND SHALL COMPLY WITH C.B.C. SEC. 1010.1.6 8.EXTERIOR DOORS TO BE FULLY WEATHER SEALED. 9. PROVIDE NOT MORE THAN 1/4" GAP UNDER ALL EXTERIOR DOORS (TYPICAL). 1.ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 2.ALL HARDWARE SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL HARDWARE SHALL COMPLY WITH CURRENT ACCESSIBLE REQUIREMENTS. 3.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND IN THE PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP, PINCH OR TWIST THE OPENING HARDWARE. 4.EFFORT TO OPEN EXTERIOR AND INTERIOR DOORS SHALL NOT EXCEED 5 LBS. 5.THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. MAXIMUM HEIGHT OF ALL THRESHOLD TO BE 1/2". 6.MAXIMUM VERTICAL CHANGE AT EDGE IS 1/4" WITH MAXIMUM BEVEL OF OF 45 DEGREES. A7.00 DO O R / W I N D O W S S C H E D . & D E T A I L S DOOR SCHEDULE DOOR NO ROOM NO. DOOR TYPE DOOR SIZE DOOR DETAIL FRAME REMARKS WIDTH HEIGHT THICKNESS HEAD JAMB SILL 1 105 C 5'-0"7'-0"1-3/4"12/A7.00 12/A7.00 -MFR EXISTING DOUBLE SWING DOORS, NEW PAINT 2 114 G 2'-0"7'-0"1-3/4"7/A7.00 6/A7.00 -H.M.EXISTING SWING DOOR, NEW PAINT 3 115 C 3'-0"7'-0"1-3/4"12/A7.00 12/A7.00 -S.S.(N) SWING GATE 4 116 D 3'-0"7'-0"1-3/4"7/A7.00 6/A7.00 -H.M.(N) SWING DOOR, SWING INTO ROOM RE: 5 5 119 D 3'-0"7'-0"1-3/4"7/A7.00 6/A7.00 -H.M.(N) SWING DOOR W/ PRIVACY LATCH, RE: 5 6 120 C 6'-0"7'-0"1-3/4"7/A7.00 6/A7.00 -H.M.(N) SWING DOORS 7 122 D 5'-0"------------EXISTING DOUBLE SWING DOORS, NEW PAINT 8 101.6 E 3'-6"------------(N) 1H SWING DOOR; W/ STORAGE LOCKSET, RE: 5 E ----------------(E)(E) - TO REMAIN. NO WORK REQUIRED. NOTES: 1.STATER BROS. SHALL PROVIDE & INSTALL ALL DOOR FINISH HARDWARE. 2.EXISTING DOOR TO REMAIN, NO WORK REQUIRED 3.EXISTING COOLER DOOR TO REMAIN, NO WORK REQUIRED 4.* FOR LOW ACCESS DOORS, CONTRACTOR SHALL SUBMIT MANUFACTURE AND COLOR SAMPLES FOR ARCHITECT'S REVIEW AND APPROVAL. 5. FOR ADDITIONAL DOOR HARDWARE INFO CONTACT STATER BROS. REP. H.M.- HOLLOW METAL MFR.- MANUFACTURER S.S.- STAINLESS STEEL (E)- EXISTING SEE DETAILS ON THIS SHEET SLIDING COLD STORAGE DOOR SPECIFICATIONS COOLER DOOR +34 DEGREES AND ABOVE ·24 GAUGE STUCCO WHITE GALVANIZED FINISH EXTERIOR AND INTERIOR ·12" WHITE THERMALLY BROKEN AIRCRAFT GRADE EXTRUDED ALUMINUM HEADER WITH INTEGRATED DROPTRAC SYSTEM ·6" WHITE THERMALLY BROKEN AIRCRAFT GRADE EXTRUDED ALUMINUM CASINGS ·TWIN TROLLEY DESIGN WITH LARGE DIAMETER UHMW WHEELS WITH SEALED SS BEARINGS ·4" THICK FOAMED-IN-PLACE POLYURETHANE INSULATION MEETING BOT DOE AND IECC CODE R-VALUE REQUIREMENTS ·DUAL BLADE, PANEL MOUNTED SANTOPRENE GASKETS, FLEXIBLE TO -30 DEGREES INTERIOR AND EXTERIOR RECESSED HANDLES ·36" TALL SMOOTH ALUMINUM KICKPLATE ON INTERIOR AND EXTERIOR OF DOOR ·BOTTOM DOOR GUIDE SYSTEM ·LEADING EDGE HOOK AND SNUBBER TO ENSURE A TIGHT SEAL ·INSTALLATION HARDWARE TO INCLUDE 3" WOOD SCREWS AND FINISH WASHERS FOR CASINGS AND 4" LAG BOLTS FOR HEADER COOLER AND FREEZER DOOR +32 DEGREES AND BELOW ·SAME SPECS AS ABOVE ·NO HEAT CABLES IN DOOR PANEL ·HEATERS IN THE FACE CASING AND HEADER WITH THE ELECTRICAL WHIP COMING OUT THE LEADING EDGE FOR THE HEADER 5 RE V I S I O N T O A P P R O V E D P L A N S - E X I S T I N G D O O R 07 / 2 8 / 2 0 2 5 5 5 Revision to 101121930 (issued on 3/21/25) REV 1 #101124637 APPROVALS : PLNG - F. Arias BLDG - CSG 1 1 1 1 3 3 3 2 3 (E) REFRIGERATED PRODUCE (E) WALK-IN FREEZER (E) PRODUCE AREA 1 2 2 2 5 14 6 106 (E) HALL 107 (E) PRODUCE COOLER 14 14 5 7 13 8' - 9 " 3' - 0 " 5'-1" 3' - 0 " 3' - 1 1 " 16 ' - 0 " ALIGN 4'-10" 3'-3" 7'-4" 5' - 0 " 6' - 3 " 6' - 1 " 6' - 3 " 5' - 0 " 6' - 3 " 4' - 1 " 6' - 0 " 8' - 1 1 " 13'-6" 7' - 0 " 7'-7" 3'-0" MIN. 6'-8" 9'-6" 5'-3" 6'-5" 4'-4"3'-2"6'-0" 9 10 TYP. 10 TYP. 9 LP LOW HIGH (N) CUT FRUIT STATION 101.3 8 11 10 TYP. 44 4 3 3 3 3 13 FRP FRP 106 (E) HALL 107 (E) PRODUCE COOLER FREEZER 108 FR P FR P (N) CUT FRUIT STATION 101.3 CR-1 CR-1 S/S -1S/S -1 B C D D B C 1 2 1 2 1 2 PR O D U C E & C U T F R U I T S T A T I O N : EN L A R G E D F L O O R P L A N S & D E T A I L S PRINTED: 13 May 2025 I: \ M Y D R I V E \ P R O D U C T I O N C L O U D \ D R A W I N G \ S T A T E R B R O S \ 8 1 6 6 - G R O U P 7 \ 8 1 6 6 . 8 - S B 4 0 S A N T A C L A R A ( S A N T A A N A ) \ A R C H I T E C T U R E \ 8 1 6 6 . 8 - A 1 . 3 0 . D W G Tu e s d a y , M a y 1 3 , 2 0 2 5 3 : 3 2 : 0 3 P M 8166.8 GG SHEETOF SH E E T T I T L E JO B N A M E JOB SHEET NO. DA T E DR A W N B Y NO . DA T E CH E C K E D B Y IN AC C E P T I N G AN D UT I L I Z I N G AN Y DR A W I N G S , RE P O R T S AN D DA T A ON AN Y FO R M OF EL E C T R O N I C ME D I A GE N E R A T E D AN D FU R N I S H E D BY RM C A , TH E CL I E N T AG R E E S TH A T AL L SU C H EL E C T R O N I C FI L E S AR E IN S T R U M E N T S OF SE R V I C E OF RM C A , WH O SH A L L BE DE E M E D TH E AU T H O R , AN D SH A L L RE T A I N AL L CO M M O N LA W , ST A T U T O R Y LA W AN D OT H E R RI G H T S , IN C L U D I N G C O P Y R I G H T S . TH E CL I E N T AG R E E S NO T TO RE U S E TH E S E EL E C T R O N I C FI L E S , IN WH O L E OR IN PA R T , IN C L U D I N G DE T A I L S , FO R AN Y PU R P O S E OT H E R TH A N FO R TH I S PR O J E C T . TH E CL I E N T AG R E E S NO T TO TR A N S F E R TH E S E EL E C T R O N I C FI L E S TO OT H E R S WI T H O U T TH E PR I O R WR I T T E N CO N S E N T OF RM C A . TH E CL I E N T FU R T H E R AG R E E S TO WA I V E AL L CL A I M S AG A I N S T RM C A RE S U L T I N G IN AN Y WA Y FR O M AN Y UN A U T H O R I Z E D CH A N G E S TO OR RE U S E OF TH E EL E C T R O N I C FI L E S FO R AN Y OT H E R PR O J E C T BY AN Y O N E OT H E R TH A N RM C A AR C H I T E C T U R E DE S I G N P L A N N I N G , I N C . NO . DA T E S T A T E R B R O S . D E V E L O P M E N T , I N C . 3 0 1 S T I P P E C A N O E A V E N U E S A N B E R N A R D I N O , C A 9 2 4 0 8 JL RE V I S I O N RE V I S I O N 08 / 1 8 / 2 0 2 4 L ICENSED A RCHITECT STATE OF CA L IFORNIA C-41383 12/31/25 J E SUS ANT ONIO LA RA RENEW A L DATE ST A T E R B R O S . # 4 0 S A N T A C L A R A 23 6 0 N T U S T I N A V E . , SA N T A A N A , C A L I F O R N I A 9 2 7 0 5 A1.30 ENLARGED EXISTING FLOOR PLAN SCALE: 1/4"=1'-0"1 ENLARGED REMODEL FLOOR PLAN SCALE: 1/4"=1'-0"2 FINISH FLOOR PLAN SCALE: 1/4"=1'-0"3 FLOOR PLAN LEGEND LP EXISTING CMU WALL EXISTING INTERIOR WALL (N) WALL (E) COOLER PANEL (N) COOLER PANEL (N) LOW WALL, RE: 5&14/A2.10 NEW(N) RELOCATED OR TO BE RELOCATED(R) EXISTING(E) (N) FIXTURE, RE: A3.00 EQUIPMENT PLAN (E) FIXTURE, TO REMAIN (E) RELOCATED OR TO BE RELOCATED FIXTURE (E) FIXTURE, TO BE REMOVED 1 DOOR INDICATOR, RE: A7.0 A WINDOW INDICATOR, RE: A7.0 MODIFIED(M) (E) FLOOR SINK, TO REMAIN, U.N.O. FILL IN AND ABANDON (E) FLOOR SINK, U.N.O. (N) FLOOR SINK, RE: 6/A2.10 & PLUMBING PLANS (N) FLOOR DRAIN, RE: 7/A2.10 & PLUMBING PLANS (E) FLOOR DRAIN (R) FLOOR DRAIN KEY NOTES (E) FROZEN CASE, TO REMAIN (E) PRODUCE CASE, TO BE REPLACED REFRIGERATED SPEC. CASE 1-COMP. SINK (N) CUT FRUIT STATION (N) REFRIGERATED BERRY BIN (R) REFRIGERATED PRODUCE WET RACK (N) BANANA TABLE (N) DRY PRODUCE CASE 1 2 3 4 5 6 7 8 9 10 11 12 13 (N) 3-COMP. SINK (N) HAND SINK 14 15 (N) IMPACT DOORS (N) 84" SHELF (N) STORAGE RACK, 63" HIGH (N) FUROUT WALL, RE: 9/A2.10 INTERIOR MATERIALS AND FINISHES LEGEND WALL MATERIAL FLOOR MATERIAL 1.ALL ITEMS ARE EXISTING UNLESS NOTED OTHERWISE 2.SEE ENLARGED PLANS & ELEVATIONS FOR WALL FINISHES 3.SEE FINISH SCHEDULE WT-X FT-1 LVP NEW WALL TILE QUARRY TILE (E) LUXURY VINYL PLANKS, THROUGHOUT SALES FLOOR EPXY- #EXPOXY SC SEALED CONCRETE FRP NEW FIBER REINFORCED PANELS, WHITE PAINT GYP BD. PAINTED VW VINYL WAINSCOT VCT (E) VINYL COMPOSITE TILES S/S-X STAINLESS STEEL WG WALL GRAPHIC, SEE DECOR PLANS SG-1 S/S SPLASH GUARD VB VINYL BASE NORTHNORTHNORTH 1 04 / 1 7 / 2 0 2 5 4 AS I 3 - P R O D U C E L A Y O U T U P D A T E 05 / 1 3 / 2 0 2 5 1 4 CC D 1 - C U T F R U I T L O W W A L L & F R P F U R O U T W A L L 1 1 1 1 44 SL A B D E T A I L S PRINTED: 17 Apr 2025 I: \ M Y D R I V E \ P R O D U C T I O N C L O U D \ D R A W I N G \ S T A T E R B R O S \ 8 1 6 6 - G R O U P 7 \ 8 1 6 6 . 8 - S B 4 0 S A N T A C L A R A ( S A N T A A N A ) \ A R C H I T E C T U R E \ 8 1 6 6 . 8 - A 2 . 1 0 . D W G Th u r s d a y , A p r i l 1 7 , 2 0 2 5 1 2 : 3 0 : 0 7 P M 8166.8 GG SHEETOF SH E E T T I T L E JO B N A M E JOB SHEET NO. DA T E DR A W N B Y NO . DA T E CH E C K E D B Y IN AC C E P T I N G AN D UT I L I Z I N G AN Y DR A W I N G S , RE P O R T S AN D DA T A ON AN Y FO R M OF EL E C T R O N I C ME D I A GE N E R A T E D AN D FU R N I S H E D BY RM C A , TH E CL I E N T AG R E E S TH A T AL L SU C H EL E C T R O N I C FI L E S AR E IN S T R U M E N T S OF SE R V I C E OF RM C A , WH O SH A L L BE DE E M E D TH E AU T H O R , AN D SH A L L RE T A I N AL L CO M M O N LA W , ST A T U T O R Y LA W AN D OT H E R RI G H T S , IN C L U D I N G C O P Y R I G H T S . TH E CL I E N T AG R E E S NO T TO RE U S E TH E S E EL E C T R O N I C FI L E S , IN WH O L E OR IN PA R T , IN C L U D I N G DE T A I L S , FO R AN Y PU R P O S E OT H E R TH A N FO R TH I S PR O J E C T . TH E CL I E N T AG R E E S NO T TO TR A N S F E R TH E S E EL E C T R O N I C FI L E S TO OT H E R S WI T H O U T TH E PR I O R WR I T T E N CO N S E N T OF RM C A . TH E CL I E N T FU R T H E R AG R E E S TO WA I V E AL L CL A I M S AG A I N S T RM C A RE S U L T I N G IN AN Y WA Y FR O M AN Y UN A U T H O R I Z E D CH A N G E S TO OR RE U S E OF TH E EL E C T R O N I C FI L E S FO R AN Y OT H E R PR O J E C T BY AN Y O N E OT H E R TH A N RM C A AR C H I T E C T U R E DE S I G N P L A N N I N G , I N C . NO . DA T E S T A T E R B R O S . D E V E L O P M E N T , I N C . 3 0 1 S T I P P E C A N O E A V E N U E S A N B E R N A R D I N O , C A 9 2 4 0 8 JL RE V I S I O N RE V I S I O N 08 / 1 8 / 2 0 2 4 L ICENSED A RCHITECT STATE OF CA L IFORNIA C-41383 12/31/25 J E SUS ANT ONIO LA RA RENEW A L DATE ST A T E R B R O S . # 4 0 S A N T A C L A R A 23 6 0 N T U S T I N A V E . , SA N T A A N A , C A L I F O R N I A 9 2 7 0 5 A2.10 (FULLY EXPOSED) FULL GRATE SEE FINISH PLAN (HALF EXPOSED) 4" M I N . CASE HALF GRATE REMOVABLE STAINLESS STEEL BASE CONCRETE CURB (ONLY APPLICABLE AT SERVICE CASES) #3 DOWEL @32" O.C. BASE W/ 3 8" MIN. RADIUS COVE SEE FINISH SCHEDULE FLOORING SEE FINISH SCHEDULE EQ . EQ . EQ.EQ. FLOOR SLOPE 2% MAX, TYP. FLOOR DRAIN, RE: PLUMBING PLANS. 0" FLUSHED 0" FLUSHED 0" FLUSHED0" FLUSHED 1/2" PLYWOOD (E) CONC. SLAB SEE FINISH PLAN 2x STUDS @ 16" o/c. 2x P.T. PLATE w/ 5/8"Ø A.B.'s @ 48" o/c. (E ) (E ) #4 DOWEL 1/2" PLYWOOD CONC. CURB SEE FINISH PLAN SEE FINISH PLAN SEE FINISH PLAN 2" COOLER PANEL 5" 6" MA X 2x STUDS @ 16" o/c. #4 CONT. 3X P.T. SILL PLATE W/ 5/8" A.B. @ 32" O.C. 7/8" MILCOR 1/2" RADIUS 6" 2" AIR GAP 1/2" GYP. BOARD SEE FINISH PLAN SILICON SEALANT POLISHED CONC.#4 DOWEL SEE FINISH PLAN COOLER 2" SAND o/ 15 MIL. VAPOR BARRIER FIN. FLOOR WALL WHERE OCCURS PANEL CLIP W/ FASTENERS GIRT BASE CHANNEL W/ FASTENER @ 12" O.C. 1 4" X 2" DRIVE PIN @ 12" O.C. NOTES: 1.FLOOR SINKS SHALL BE 12"X12" SET FLUSH WITH FLOORING HALF OR FULLY EXPOSED(SEE DETAILS) FOR EASY CLEANING WITH HALF OR FULL GRATE COVER(SEE DETAIL). FLOOR SINKS TO COMPLY WITH RIVERSIDE COUNTY HEALTH DEPARTMENT CODES AND REGULATIONS. CONTRACTOR SHALL VERIFY AND COORDINATE LOCATION OF FLOOR SINKS WITH REFRIGERATION & PLUMBING (PRIOR TO INSTALLATION OF WORK). BASE AT COOLER W/ CURB DETAIL SCALE: 1"=1'-0"4 6" EXISTING 8" MASONRY WALL INSULATED PANELS SILICON SEALANT 7/8" MILCOR 1/2" RAD. 2" AIR SPACE COOLER WALL BASE DETAIL SCALE: 1 1/2"=1'-0"3 BASE AT COOLER W/ CURB DETAIL SCALE: 1"=1'-0"1 2X4 STUD AT 16" O.C. 5 8" GYP. BD. SHEAR WALL 2X4 P.T. PLATE W/ 1 2" Ø A.B. AT 48" O.C. MAX. 12" FROM ENDS AND CORNERS WALL MAT. SEE FINISH PLAN 2x4 AT 16" O.C. (FLAT) 2X4 P.T. PLATE W/ 1 2" A.B. 72" O.C. 2 1/2" INSULATION WALL MAT. SEE FINISH PLAN 1 2" GYP. BD. 2" 4" 23 8" 6" 67 8" 914" ℄ #4 DOWELS AT 48" O.C. SEE FINISH PLAN FLOOR SINK SCALE: NONE 6 WALL TO CURB DETAIL SCALE: 1 1/2" = 1'-0"2 DELI LOW WALL DETAIL SCALE: 1 1/2" = 1'-0"5 FLOOR DRAIN SLOPE SCALE: NONE 7 COOLER CONC. CURB CONT. SEALANT RUBBER SEAL GLASS COOLER DOOR (E) CONC. SLAB (E ) 9" SALES AREA 3 8" CHAMFER 5/8"R 2X6 PRESSURE TREATED PLATE DOOR TO CURB DETAIL SCALE: 1-1/2"=1'-0"8 EXISTING CMU FRP 12" PLY WOOD 250T125-33 METAL STUD FASTENED W/ 114" SHOT PIN @ 12" O.C. 8' - 0 " A . F . F . 250S125-33 METAL STUD 200A200-54 (1) #10 SHT. MTL. SCREWS @12" O.C. 114" SHOT PIN @ 12" O.C. FURR OUT AT CMU SCALE: 1"=1'-0"9 (E) FRAMED WOOD WALL FIELD CUT THERMAL BREAK (E) CMU WALL VAPOR BARRIER 18 GA. METAL STRAPPING INSULATED WALL PANEL PER PLAN 2x WOOD BLOCKING 2"x2"x26 GA. INSIDE CORNER TRIM W/ #8x3/4" TEK SCREW INTO PANEL @ 8" O.C. ONE SIDE. LINER TO LINER CONNECTION AT FRAMED/CMU WALL SCALE: 1-1/2"=1'-0"10 INSULATED WALL PANEL PER PLAN 18 GA. GALV. CLIP FASTENED @ PANEL JOINT W/ #14x1-1/2" WOOD SCREW SCREWED INTO (E) FRAMED WOOD WALL INSULATED LINER PANEL PER PLAN 18 GA. GALVANIZED STRAPPING @ EACH STUD FIELD APPLIED BUTYL SEALANT ON WARM SIDE (E) FRAMED WOOD WALL INSULATED PANEL JOINT CONNECTIONAT FRAMED WALL SCALE: 1-1/2"=1'-0"12 RE: 4/A1.61 INSULATED WALL/ CEILING PANEL FIELD APPLIED BUTYL SEALANT PANEL CONNECTION JOINT CONTINUOUS BUTYL SEALANT (AT "WARM"SIDE JOINT)COLD SIDE "WARM" SIDE WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY INSULATED PANEL JOINT AT INTERIOPR PANEL SCALE: 1-1/2"=1'-0"13 FRAMED WOOD WALL VAPOR BARRIER INSULATED WALL PANEL PER PLAN 2" x 2" x 26 GA. INSIDE CORNER TRIM W/ #8 x 3/4" TEK SCREW INTO PANEL @ 8" O.C. FIELD CUT THERMAL BREAK INSULATED WALL PANEL PER PLAN LINER TO LINER CONNECTION AT FRAMED WALL SCALE: 1-1/2"=1'-0"11 CONCRETE CURB (E) CONCRETE SLAB #4 @32" O.C. HOOKED EPOXY DOWEL, W/ 3" EMBED SEE FINISH PLAN SEE FINISH FLOOR PLAN SEE FINISH PLAN SEE STRUCTURAL PLANS 20 GA. STAINLESS STEEL CAP WITH EASED EDGES AT TOP (AT SERVICE DELI) PLYWOOD SUBSTRATE AT TOP OF WALL AT MEAT SERVICE CASES, BREAK METAL FINISH TO MATCH CASE ON CUSTOMER SIDE, U.N.O. TILE CUT FRUIT LOW WALL DETAIL SCALE: 1 1/2" = 1'-0"14 (E) CONCRETE SLAB #4 @32" O.C., W/ 3" EMBED 35 1 / 2 " GLASS SNEEZE GUARD (WHERE OCCURS) SEE FINISH PLAN SEE FINISH FLOOR PLAN SEE FINISH PLAN 60 " SEE STRUCTURAL PLANS SOLID SURFACE TOP MATCH ADJACENT SERVICE CASE AT CUT FRUIT RUBBER BUMPER AT CUT FRUIT - BREAK METAL FINISH TO MATCH CASE ON CUSTOMER SIDE, U.N.O. 1 04 / 1 7 / 2 0 2 5 1 CC D 1 - C U T F R U I T L O W W A L L & F R P F U R O U T W A L L 11 1 D B A C 1 3 4 5 62 D B A C 1 3 4 5 62 EXIT EXIT EXIT EXIT EXIT D B A C 1 3 4 5 62 D B A C 1 3 4 5 62 1 1 13'-10" 7'-10" 7'-6" 7'-6" 1 8'-3" 1 OPEN 8'-5" 7'-6" G 2 2 (E) REFRIGERATED PRODUCE (E) WALK-IN FREEZER (E) STORAGE (E) ALL GENDER RESTROOM (E) ELEC. EQUIPMENT (E) BLOOM BOX (E) POTS/PANS CLEANUP (E)MEAT, DELI & DAIRY COOLER (E) RECEIVING DESK (E) GROCERY STORAGE (E) LIQUOR & CIGS STORAGE (E) SALES AREA (E) HALL (E) PRODUCE AREA (E) ALL GENDER RESTROOM (E) HALL 7'-6" 3 3 3 3 PRINTED: 07 May 2025 I: \ M Y D R I V E \ P R O D U C T I O N C L O U D \ D R A W I N G \ S T A T E R B R O S \ 8 1 6 6 - G R O U P 7 \ 8 1 6 6 . 8 - S B 4 0 S A N T A C L A R A ( S A N T A A N A ) \ A R C H I T E C T U R E \ 8 1 6 6 . 8 - A 4 . 0 0 . D W G We d n e s d a y , M a y 7 , 2 0 2 5 1 1 : 3 3 : 3 9 A M 8166.8 GG SHEETOF SH E E T T I T L E JO B N A M E JOB SHEET NO. DA T E DR A W N B Y NO . DA T E CH E C K E D B Y IN AC C E P T I N G AN D UT I L I Z I N G AN Y DR A W I N G S , RE P O R T S AN D DA T A ON AN Y FO R M OF EL E C T R O N I C ME D I A GE N E R A T E D AN D FU R N I S H E D BY RM C A , TH E CL I E N T AG R E E S TH A T AL L SU C H EL E C T R O N I C FI L E S AR E IN S T R U M E N T S OF SE R V I C E OF RM C A , WH O SH A L L BE DE E M E D TH E AU T H O R , AN D SH A L L RE T A I N AL L CO M M O N LA W , ST A T U T O R Y LA W AN D OT H E R RI G H T S , IN C L U D I N G C O P Y R I G H T S . TH E CL I E N T AG R E E S NO T TO RE U S E TH E S E EL E C T R O N I C FI L E S , IN WH O L E OR IN PA R T , IN C L U D I N G DE T A I L S , FO R AN Y PU R P O S E OT H E R TH A N FO R TH I S PR O J E C T . TH E CL I E N T AG R E E S NO T TO TR A N S F E R TH E S E EL E C T R O N I C FI L E S TO OT H E R S WI T H O U T TH E PR I O R WR I T T E N CO N S E N T OF RM C A . TH E CL I E N T FU R T H E R AG R E E S TO WA I V E AL L CL A I M S AG A I N S T RM C A RE S U L T I N G IN AN Y WA Y FR O M AN Y UN A U T H O R I Z E D CH A N G E S TO OR RE U S E OF TH E EL E C T R O N I C FI L E S FO R AN Y OT H E R PR O J E C T BY AN Y O N E OT H E R TH A N RM C A AR C H I T E C T U R E DE S I G N P L A N N I N G , I N C . NO . DA T E S T A T E R B R O S . D E V E L O P M E N T , I N C . 3 0 1 S T I P P E C A N O E A V E N U E S A N B E R N A R D I N O , C A 9 2 4 0 8 JL RE V I S I O N RE V I S I O N 08 / 1 8 / 2 0 2 4 L ICENSED A RCHITECT STATE OF CA L IFORNIA C-41383 12/31/25 J E SUS ANT ONIO LA RA RENEW A L DATE ST A T E R B R O S . # 4 0 S A N T A C L A R A 23 6 0 N T U S T I N A V E . , SA N T A A N A , C A L I F O R N I A 9 2 7 0 5 RCP LEGEND (N) NEW (D) DEMO (E) EXISTING 2x4 GRID CEILING W/ TILE, RE:5/A4.10 REPAINT & REPLACE AS REQUIRED BY SBM CEILING HEIGHT GYP. BD. CEILING W/ PAINT L.E.D. DROP IN FIXTURE COOLER LIGHT STRIP SURFACE MOUNT LIGHT FIXTURE SERVICE AREA L.E.D. LIGHTING STRIP, SOFFIT FACE MOUNT HEADER TRACK LIGHTING X'-X" SALES FLOOR L.E.D. LIGHTING STRIP M MOTION SENSOR EXISTING REFLECTED CEILING PLAN SCALE: 1/8"=1'-0"1 GENERAL NOTES 1.FOR ADDITIONAL INFO COORDINATE WITH STATER BROS. FIXTURE PLAN. 2.ALL KITCHEN EQUIPMENT AND ALL SINKS ARE SUPPLIED BY STATER BROS. ASSEMBLED AND INSTALLED BY STATER BROS. 3.ALL CUSTOM COUNTERS AND MILLWORK, BY STATER BROS. 4.AT ALL HAND SINK LOCATIONS, PROVIDE A HAND SOAP DISPENSER AND A PAPER TOWEL DISPENSER. 5.SEE A1.21 FOR FINISH PLAN 6.SEE A3.00 & A3.10 FOR EQUIPMENT PLAN & SCHEDULE 7.SEE A2.00 & A2.10 FOR SLAB PLAN & WALL DETAILS 8.SEE A4.00 & A4.10 FOR RCP AND DETAILS 9.REMOVE EXISTING WALL MOUNTED LIGHT FIXTURES, SCONCES ONLY, DELIVER TO STATER BROS. MARKET AS REQUIRED. NORTH KEY NOTES REMOVE EXISTING CEILING TILES (E) SOFFIT1 2 REMOVE EXISTING COILS3 RE F L E C T E D C E I L I N G P L A N A4.00 1 04 / 1 7 / 2 0 2 5 2 1 2 CC D 2 - P R O D U C E P R E P C O I L S CC D 1 - C U T F R U I T L O W W A L L & F R P F U R O U T W A L L 05 / 0 7 / 2 0 2 5 3 3 3 CA. 626-357-5225 Review is only for general confori o4 the submittal with information and the design concept expressed Contract Documents. Comments during thls review do not reliev Contractor from compliance will requirements of those Cc Documents. The Contractoi responsible for confirming correlating all quantities, dimension; conditions, construction m methods, sequences, procedures ar coordination of all tr No Exception Taken fief Notations — Revise and Resubmit Rejected _ Submit spesifi em Relerned Unr ;r �X Sol�e 3��.► CITYfj SANTA ANA e 6 d Building Agency 4—f!' ; Approved FOR PERMIT ISSUANCE ;1 t• Mastor ID: I, it P,xY SLI S 11 OFF IT �V/4�Z Ste '' 0 �/