Laserfiche WebLink
LEGEND AND ABBREVIATIONS <br />DISCLAIMER: PLEASE NOTE THAT THE ABBREVIATIONS, ANNOTATIONS, AND SYMBOLS LISTED ARE <br />INTENDED TO ILLUSTRATE THOSE THAT ARE COMMONLY USED; NOT ALL ARE NECESSARILY <br />UTILIZED WITHIN THIS SET OF DRAWINGS. <br />ATTIC VENT <br />FLUSH ATTIC VENT <br />PVC PIPE VENT <br />SATELLITE DISH <br />T-VENT <br />CHIMNEY <br />FIRE SETBACKS <br />METAL PIPE VENT <br />HARDSCAPE <br />PROPERTY LINEPL <br />MAIN PANEL & SUB <br />PANELS <br />INVERTER(S) WITH <br />INTEGRATED DC <br />DISCONNECT AND AFCI <br />GENERAL LOCATION OF <br />EQUIPMENT <br />METER SOCKET & <br />DISCONNECTS <br />PV LOAD CENTER <br />BESS <br />(IF APPLICABLE) <br />GENERAL NOTES <br />VICINITY MAP <br />AMPERE <br />ALTERNATING CURRENT <br />AC DISCONNECT <br />AMERICANS WITH DISABILITIES ACT <br />AVAILABLE FAULT CURRENT <br />AMERICAN SOCIETY FOR TESTING AND MATERIALS <br />BATTERY ENERGY STORAGE SYSTEM <br />BUILDING <br />CLEAR <br />CARPORT, NEW <br />CONCRETE <br />CONDITIONS OF USE <br />CARPORT, RETROFIT <br />DIRECT CURRENT <br />DIAMETER <br />DISTANCE <br />EQUAL <br />EQUIPMENT GROUNDING CONDUCTOR <br />EXISTING <br />EACH <br />ELECTRICAL METALLIC TUBING <br />GALVANIZED <br />GROUNDING ELECTRODE CONDUCTOR <br />GROUND <br />HOT DIPPED GALVANIZED <br />CURRENT <br />CURRENT AT MAX POWER <br />INVERTERS <br />SHORT CIRCUIT CURRENT <br />KILOVOLT AMPERE <br />KILOWATT <br />KILOWATT-HOUR <br />LOAD BEARING WALL <br />MAXIMUM <br />MINIMUM <br />NEW <br />NATIONAL ELECTRIC CODE <br />NOT IN CONTRACT <br />NOT TO SCALE <br />ON CENTER <br />OVERCURRENT PROTECTION <br />POWER CONTROL SYSTEM <br />PROPERTY LINES <br />PHOTOVOLTAIC <br />POLYVINYL CHLORIDE <br />ROOF, BALLAST <br />ROOF, FLUSH MOUNT <br />SCHEDULE <br />SQUARE INCHES <br />STAINLESS STEEL <br />SEE STRUCTURAL DRAWINGS <br />STANDARD TESTING CONDITIONS <br />TYPICAL <br />UNLESS OTHERWISE NOTED <br />UNINTERRUPTIBLE POWER SUPPLY <br />VERIFY IN FIELD <br />VOLT <br />VOLTAGE AT MAX POWER <br />VOLTAGE AT OPEN CIRCUIT <br />WATT <br />NEMA 3R, RAINTIGHT <br />A <br />AC <br />ACDS <br />ADA <br />AFC <br />ASTM <br />BESS <br />BLDG <br />CLR <br />CN <br />CONC <br />C.O.U <br />CR <br />DC <br />DIA <br />DIST <br />EQ <br />EGC <br />(E) <br />EA. <br />EMT <br />GALV <br />GEC <br />GND <br />HDG <br />I <br />Imp <br />INVS <br />Isc <br />kVA <br />kW <br />kWh <br />LBW <br />MAX <br />MIN <br />(N) <br />NEC <br />NIC <br />NTS <br />OC <br />OCP <br />PCS <br />PL <br />PV <br />PVC <br />RB <br />RF <br />SCH <br />SQ. IN. <br />SS <br />SSD <br />STC <br />TYP <br />UON <br />UPS <br />VIF <br />V <br />Vmp <br />Voc <br />W <br />3R <br />ABBREVIATIONS <br />DESIGN WIND SPEED: 96 MPH <br />EXPOSURE: B <br />SNOWLOAD: 0 PSF <br />WEATHER STATION: POLARIS DATA <br />DESIGN LOW TEMP: -2°C <br />2% DRY BULB: 38°C <br />SDS: 1.039 <br />MOUNTING PLANE HEIGHT(S): 20 FT <br />BUILDING STORIES: 2 <br />CONSTRUCTION TYPE: V <br />OCCUPANCY GROUP: R-2 <br />AUTOMATIC FIRE SPRINKLERS: No <br />PROJECT INFORMATION <br />RAIL <br />STANDOFFS & <br />FOOTINGS <br />SOLAR MODULES <br />AERIAL MAP <br />SITE NOTES: <br />·A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. <br />·THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. <br />·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. <br />·ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S <br />INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. <br />·NO CHANGE TO PARKING OR STRIPING <br />·PV MODULES ARE TYPE I FIRE RATED AND THE CARPORT STRUCTURE IS OPEN AIR AND NON-HABITABLE. <br />EQUIPMENT LOCATIONS: <br />·ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. <br />·WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND <br />NEC TABLES 310.15 (B)(1) AND 310.15 (B)(2) IF RACEWAYS ARE < 7/8" ABOVE THE ROOF. <br />·JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. <br />·ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. <br />·ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. <br />·ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. <br />STRUCTURAL NOTES: <br />·RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE <br />BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL <br />MANUFACTURER’S INSTRUCTIONS. <br />·JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL <br />REQUIREMENTS. <br />·ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED <br />CONTRACTOR. <br />·ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. <br />·WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. <br />DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: <br />·DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO <br />THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). <br />·DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. <br />·DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED WITHIN 6 FT, ACCORDING TO NEC 690.15(B). <br />·ALL PV CIRCUITS LOCATED OUTSIDE THE ARRAY BOUNDARY OR MORE THAN 3 FT FROM THE POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT <br />MORE THAN 30 VOLTS WITHIN 30 SECONDS, CIRCUITS INSIDE THE ARRAY BOUNDARY OR NOT MORE THAN 3 FT FROM THE POINT OF PENETRATION SHALL BE <br />LIMITED TO NOT MORE THAN 80 VOLTS UPON RAPID SHUT-DOWN INITIATION PER 690.12. <br />·ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. <br />WIRING & CONDUIT NOTES: <br />·ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE <br />REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. <br />·CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. <br />·ALL CONDUIT MUST ACCOUNT FOR ENVIRONMENTAL CONDITIONS AND THERMAL EXPANSIONS ACCORDING TO NEC 300.7. <br />·PV WIRE BLACK WIRE MAY BE FIELD-MARKED BY MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, <br />TAGGING, OR OTHER APPROVED MEANS. <br />·MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. <br />·RACKING, MID CLIPS, END CLIPS, AND MODULES UL2703 LISTED <br />·ACCORDING TO NEC 200.7, SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS: <br />···DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GRAY AND GREEN <br />···DC NEGATIVE- BLACK, OR ANY COLOR EXCLUDING WHITE, GRAY AND GREEN <br />·AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: <br />···PHASE A OR L1- BLACK <br />···PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE <br />···PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION <br />···NEUTRAL- WHITE OR GRAY <br />*IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. <br />CODES AND STANDARDS <br />SHEET INDEXBILL OF MATERIALS <br />NEW PV AND ENERGY STORAGE SYSTEM: <br />ON ROOFPV SYSTEM: 31.16 DCkW, 22.8 ACkW, 29.035 CEC ACkWENERGY STORAGE SYSTEM: 11.4 ACkW, 29.1 kWHTOWNSEND & RAITT I817 S TOWNSEND ST, SANTA ANA, CA 92704, USA <br />APN #: 109-611-20 <br />BUILDING: IBC 2021 <br />LOCAL BUILDING: CBC 2019 <br />OCCUPANCY GROUP: R-2 <br />ELECTRICAL: NEC 2020 <br />LOCAL ELECTRICAL: CEC 2022 <br />FIRE: CFC 2022 <br />AHJ: CITY OF SANTA ANA <br />UTILITY: SCE <br />MODULES: <br />(76) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 <br />OPTIMIZERS: <br />(76) SOLAREDGE U650 <br />INVERTERS: <br />(2) SOLAREDGE SE11400H-US HOME HUB [SI1-SB] <br />MONITORING: <br />MANUFACTURE INTEGRATED <br />BESS: <br />(3) SOLAREDGE BAT-10K1P <br />(1) SOLAREDGE HOME NET CARD <br />(3) SEDG FLOOR MOUNT <br />RACKING: <br />FLUSH ROOF: ULTRAFOOT RAFTER - 1 LAG <br />C100 : COVERSHEET <br />E100 : ELECTRICAL SITE PLAN <br />E200 : ELECTRICAL PLAN VIEWS <br />E300 : ELECTRICAL STRINGING <br />E400 : ELECTRICAL DETAILS <br />E401 : ELECTRICAL DETAILS <br />E500 : ELECTRICAL NOTES <br />E600 : ONELINE DIAGRAM POI-1 <br />E800 : WARNING LABELS <br />E801 : WARNING LABELS <br />E810 : SITE PLACARDS <br />S100 : STRUCTURAL SITE PLAN <br />S200 : STRUCTURAL ARRAY DETAIL <br />S300 : STRUCTURAL SIDE SECTIONS <br />S400 : STRUCTURAL ATTACHMENT DETAILS <br />R100 : REFERENCE SHEETS <br />R101 : REFERENCE SHEETS <br />R102 : REFERENCE SHEETS <br />C:\USERS\THADDEUS.STEERMAN\DESKTOP\WORKING PROJECTS\1233 - TOWNSEND & RAITT I\3 VA - AHJ COMMENTS AND MOD SWAP\1233_TOWNSEND & RAITT I_CAD_V0\TOWNSEND & RAITT I.DWG <br />COVER SHEET <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />TOWNSEND & RAITT I <br />817 S TOWNSEND ST, <br />SANTA ANA, CA 92704, USA <br />APN:109-611-20 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL05/14/25 <br />AAHJ COMMENTS 08/08/25 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·31.16 kW DC <br />·22.8 kW AC <br />·29.035 CEC AC <br />ENERGY STORAGE: <br />·11.4 kW AC <br />·29.1 kWH <br />C100 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: FINS_PK <br />A <br />CONTRACT NUMBER: <br />3003197588 <br />PJT #: PROP-001233 <br />A <br />A <br />A <br />Bldg# 101124141 <br />Elec# 20186225 <br />& 20186819 <br />APPROVALS: <br />PLNG - CSantana <br />BLDG - TLe <br />ELEC - MSmith