Loading...
HomeMy WebLinkAbout10195752 - Permitq Project Address: 2009 S Halladay St Assessor's Parcel:o't4-113-23 Lot: 3 Bldg: Address Range Suite Range: Zoning; R'lBlock 10 Tract 550 Historc No City of Santa Ana 20 Civic Center Plaza (l\il-19), Santa Ana, CAg27o2 Building Permit Counter: (714) 647-5800 lnspection Requests: 17'l4l667-2738 lnspector Section: (714) 647-5853 Permit #: 1(J195752 Pin #: 15117 Building Use: Job Type: Nature of Work: Existing Bldg. & Use Proposed Use: Duplex Solar Solar SFO Wdet garage Residential Occupancy: Constr Type Code: Flood Zone. # of Stories: R.3, U VB cBc 2016 x4602320276J 1st FL Area: 2nd FL Area: Other Areas: Garage Area Total: Patio: T l.Area: Yards Req'd: Valuation:$22,000.00 Oescription of Work: lnstall (27) roof mounted solar panels. Per checklist Owner: Addressl Phone: Tenant Julio Flores 2009 S Halladay Street Santa Ana, CA 927072903 (7141 403-3927 Conlraclor Star Sun Solar LLC Address: 12966 Euclid Street, #550 Garden Grove, CA 92840 Phone; (714'1 530-8777 State Lic #: 1008302 Lic Type: C-10 Bus. Lic #r 363540 Workers' Compensation lnsurance: Carrier: State Compensation lnsurance Fur Policy : 9169581 Expires: 1112112018 oass Strg+t{rfll.F4gi1pprs i..,, .,rr1t IDr r 1,,1,:,,ir.,Pmveen PaFl. e: .lyH ti.rrrsi: or.r iL,r l 1655 She{tinglqn ?lace, Z-2O2 F:ptiI 1lll9':i/l-r Newport Esedr,[gA lf,tDBE ,j,\/?tr1g 2:1]7 I'n (949) 295.7lx&,r,-t tor ['rt(l t5rrt'rir-l 74200 ,rr. Sun 5c,lol' I t I t:;u(r.l:l( t1 . irtl $5(t1 . (r(l Engineer Address Architect / Desiqner: Address: Phone: License # ri ld rns I I t6UUl- 5l6r:rl r-rrru- lds Stds ftevolv ios I I 161-r[2- 5l612r.ltrr-r-I Chegh t"rU:,;966 Planning Approval By Plan Checked By: Permit lssued By: NPDES lnsp. Req'd: PWA lnsp. Req'di Planning lnsp. Req'd Amsden. Julie Date: Date: Date: 03/05/2018 Subject to Field: Misc. Receipi Misc. Receipt Misc Receipt $500.00 $1.00 $0.00 07776002 51501 Permit Fee 07776002 57672 gldq. Slds. Revolving 07776002 57600 Genetal Plan Update?No No No No Fire lnsp. Req'd: Police lnsp Req'd No No Account#Total Landscaping lnsp Req'd Flood Zone Cert. Req'd: No 011t6002 S1601 Every pemit issued shell becone invalid unless the wod< on the sile authonzed by such permit ts cofimenced wilhinlS0days €ftet its issuance,ot if lhe wo* aulhoized on lhe site by such peml is suspended ot abendoned for a peiod oi,180 days aftet the lime the wotu is cofimenced . lnspector MtD#. 2018-141852 01 1 16002 51612 $500.00 $1.00 Fee Tolal Paid to Date. Balance Oue $501 00 $0.,t0 050't o0 Unit Planning Conditions: Phone: License # BUILDING- INSPECTOR RECORD DATE ID/SIG.COMMENTS oll NEX AUILDER DEL('ANAT|()N I had, allm uidq Fllly of p.rrury lhd I n dmF 6on th. Cod,rdots l-rw l,* for rh. Llk'qrs rdn (iic 7Ol L Itcin6s ad lkradion cod.): A.y City oi (nudy shich r.qut6 a ,6!n kr $'Blrud, all6. improvq ddnolish or rqutr M, .rrudu.. Fir 'o iis !ffie ito qur6 rh. q,pliEl ror 3uch Fmn to liL i !'sn d {rr'6r thi lE or !h. u lEnR.d ld&ut ro d. rmvdiotu oflh. (orl,tcld's l-rcdscd l,w (Cll.FaF 9, (i'mntrins enh S{1or 7000 of Divtrn I ofln. B{sin6 and Pmf*ions cod.) orrharlr or.h. ii.rdfl rhocGon !d rh. b6! tor rhc dks.d.toflN Anv rrcL{mnoISdIn 70]15 h}.ny lpplicul for r rcnil rubds rlE lprlrcml ro . cn il p.mhy of frn mr. rho lit. hundral dollnr I ls00) l. a osG of th. ForEly. tr hy.,rphlE ai'h $+6 a ln.t $k $.rr.Mio.. $ill d, tt $rrt rt Etumi!Ln iidi.d Dr ofracd ad rr& (Sa 70{t, IIBitB dd PrefsN Cod. 11'. (nltrrrr'. l,rc l.* dE N ,c?ly to d o$E of rhc Frpdty ulx' hoild! or inrpruvBltEqrq ud sb do6 uch $!d hirucllor h.Glaor lhoush hi! o. hs oM6pk,y.6. prolilql rhd $.h trnForEld. c d -rdrLd d oturd [* 5t ll rFEd. rlr txid,s 6r n+rnqci ar sld r'rh ft ]6 ofon{ dbr llE Of,E BuiltE rillllw tlE hd6 of Fnrin! d{ h. or Jk {!n d, bild or nF.!r. U. FDFry ad tlE t nIB of I. 6 o*G of rh. FntEty. m.rclurv.lycod,&1itr* w'rh lic6r.d conr,&-loR lo codru.1llE FmJ<r (56 7044- l,l!ffi ltd ltoksm (ild.: lt. Conlr&tols l.i.d.l-.w do6 nor apprr ro d o$nd.fp.oFnt wno build! or nnplovd rh6dn, .nd who codr&rt ld.kh FF! rnh. Cod8ro(r) lE6Ed Frrut toln. (bnr ld! lid L.*) I dn.\.mfl undn sdrio. D.tc 0*16: woRrirRs, coriiENsAltoN OICIAMIIAT I h(.br rilm undd Fnint of raJUry o.. of th. folbu Es d(lelxoN I h*.8l *,ll @'nl.n r Carrfr . of CoB{ t' Sclf.lME t$ salt6 orrrEldirn. d p.rr d.d tor ti! SdlM l7O0 of rlr lrhir c.dc. lor rh. pofomdcc ollh. wort [or q hich rtu pahi! ir su.d il I h^. lnd q ill Mid.'n $0A6 (omFGdl,n 'tu.rq a (qw!d 1^ s..tri 1'700 olirE l.bor C.&. ir rlt Fftu. of lh. $n* for shEh inii Fmil ir sr.d M, wort6 codnoaaion Euocc cdid &d lolq nunb.r e. ..,*,31,rl,i {,,t-,i Po,k,N6bG lrC qtit [onuli,dlco-- -_- {&tC _ _0.,^rLlurtvort -l cqlitylhdt in rn Ffom.n.c oarh. work for trhi:h r his pmir is i$u.d. I shdll n.t mtloy rny F$n in sy nrinna $ a t' b..om r!q6r ro 'h. *trtd omF!di,. h*! orcJifomq {rj rsc rh, if I irhuB t (tu $b<l ro rtE r!*6 ompdsion Fo\ irhB of Sdbn l7cr) oa$. lrtd cdL, I .luu- lonh* nh 6mpl, snh rbqr.y6ro6 WABNINC: rlrluc ro *u. *orle comparrion cor63[. i! unllwful. md rtull subjer u nploF to qiminal Fr.hi6 od csil n.6 up ro or l$ndrcd rhoend &,lkr (lll)0.0@). in ddnion ro rh. coll of sGrion 1076 otrlEt U, Coda dr6d ud drorE rfs n'n. d.nq6 a pro\dcd fttr ri. t\\1.\{l-roti LlctltELcoNrtal:Iof,Dlcldaallo! I Hr,.lTmo jd Fuh, of Fjurt rhd I m lrc.Gdi !n s Fo!.6i ol (.tieG , {smffiis snh Sdi nn 7Ux,) oa Dr\ nion I of lh.IhinB s<t Pra6ioN ( o&. lxl ny lrc@ n B tuI loN &d cfl..l. (ANIiIAICIIANITTDIIGICIICI I hftny arrd rnld Fnalr, .f tFju' r_ rh.r 'hd. s s c.nsrrud nn lqldra ax6cy ror rh. p{forfucc or rh. \ orl for s h.h rhtr Ffri 6 issu.d (sd 10,17,civ ( ) AIILICANI.DI;CI.d.BAIIA! I hddt t tm ufrr6 Fr.h) of FJu '- oE or th. fououif,[ &(lr, iof,s D.mohlptr Pm s-kb6ros No' ifi.di.n l.d6,l Rcguld{B (Tnk40. Pd6) --R.qurcd L.ir6 of Mxi6dion I rdiry th.l rh. f.rL.rl r.suldD6 r.lfidins stElor rmo\ .l s. not ifi'li(ahl. lo rhn 'rNFs irhar I h.v.r.adrhisaprh.arionmdsrrr.rhalrhcrh)vc rtrfomdL,n B corNt I aarerolofl,plysnhallC(tsnd ( otrmy md srar€ tr$s rcldi.g u &iildi.g codrudio( ari .ultFtu r.!.6aidivd olrhr C y rnd cou.r! N 016 trN. ih. .h\. f,hrFn d pNFt) fd 'r$Cri)n DUrxE. rpplic{trror.\ss signrlur(nrlr; aNrrlo uoti Sel Backs Forms/Steel/Holdowns Erection Pads UFER Ground SLAB Floor Subf loor/VenUl nsulation Roof Sheathing Shear Wall Framing I nsulation/Energy Drywall Ext./lnt. Lath Brown Coat Masonry Pool Fence T-Bar Handicap Req Deputy Final Report Engineer Final Report rl FINAL )t lb ,tl@ Certificate of Occupancy Notes Remarks, Etc. SITE-WORK ( I I I I I I I Flood Zone Certif. Planning & Building Agency 20 Civic Center PIaza Ross Annex P.O. Box 1988 (M.19) Santa Ana, CA 92702 (7'14) 647-5800 'N...sanla-ana.ot al rNsP,02 2013 CRC This document moy be found at h tto.i/,,,r,,r,'i. sa rtr -3n-i.o.q. ooa' (Please use a black or blue ink ball-point pen) Project Addres s: Permit Number:totq€v Contractor:6;.. 5,o\an-License #:o State of California requires that smoke and carbon monoxlde (CO) alarms are installed in residential buildings. California Residential Code (CRC) Section R314.1 and R315.2 states in part that existing dwellings be "retrofitted with smoke alarms and carbon monoxide alarms. CRC Section R314.3 and R314.3,3 define the required locatio ns. 4\ eo,h boxes betow must be checked: SC"rUon monoxide alarms: Are installed outside of each sleeping area in the immediate vicinity of bedrooms and also on each level of the dwelling. Alarms are required in bedrooms with gas-fired appliances (i. e. hot water heater, cooktop, furnace) or a fireplace. fl Smot<e alarms: Are installed in each room used for sleeping, in each hallway outside of a sleeping room, and on each level of the dwelling. Retrofitted detectors may be battery-operated for buildings where no interior alterations are performed. Combination Smoke/CO alarms must comply with all applicable standards and be approved by the State Fire Marshall (5FM). Battery life must be 10 years. I hereby certify that I am the contractor or the property owner of the above project. I further certify that smoke alarms and carbon monoxide alarms have been installed in compliance with the governing Codes and have been tested to be functional. l, also, hereby certify that I will retest the alarms per the m an ufactu rer's instruction s. Signoture:3 o 2ot lcheck onel Lice n se d Con tractor tr P ropert Owner NoTE: rhrs self-certiJicotion is only used lor projects that aflect the ErTERIOR of the structure. This process is opplicable ONLY to projects where access to the interior of the dwelling by a Santo Ano lnspector is not required. ?oo K J e Dot e: Have this completed form and the job-card readily available on final inspection! Smoke & CO Alarm AffidavitI i Property Owner: I l L I dF.dZcd.Fa-dUcdc-Fda-Fa >/1 Y at \U ) r ln0a lI ] T \- / () t( )a, : l_ ) a( .o& = FE t _ E- o o €r : E E : s: : m E g e; ; 5 ; E ; E = P: E .? c : ; ; . v J. q a ; , ! ! g; P A E E =p : ; ! - or r 7 6 - E r o EA : * E : 9; . E ts . E 5p 1 8 t E eh i i € E : d r' = 6€ 2= - t c c eE I E - . E; o t r o O -a = E = = f ?x E E + E Pi , t g. ; f "9 i 9. * c E -, : ' = 5 E - !u , u o ( ! l ! 6 +o F. E \! E! 9 a i i o YY C O T ( . ) . n -[ i I n " E E it (l . ) f/ . t r o - - o. F -o o) 9 .9 6 Do - i : > { ) - ; E d 6I = !. 9 EE ; E i 5 ] 3 '= o - E u, =. : Z -' C) * - . c c E , ! -c = U o o O 9 FE ( ! ; . O E I ? ^r r 9 d r o- oJ > E; .= 'o P Eh EE E s ; A >. ; E [i A- = >, o c -i a 6, = 6) 1a E 1 Et r , f s T E TE E uq ; E o aO *> , 6 bO <o ( ' , t r t r -! > of i oc i r - . E E 3 3s € B. v e !\ ' f rs O) .e ! ; = E l! 6 ( , F : ; o ', - q q di EE = E ar (, , >, _ Jj EE = U E - s .9 6 q, o: ( ! t r ! . EE E E E U _o . r 9 or - :E ! o t Jl ! - >. r p eE E E g H; s g S E! E g E" E E a i€ : ; E - h: P 5 5 0 .J ! ^ o ; 6 (n sl J I o= ,E H g 3E E Fo E 5 0 - . = 2If JFclj - lj Jt- ,, I ri )c- '- lJ cz tf JC- II , JFtuxL. I J >5o: - rr : c, !! dr =a q -' >= - iJ c +b 6 :] l! g , - F { r * . ! B 6' e = E= : ,> vU :' : - Eo _ e, ! :l - = eE 8e S: . :o , ^ a E . n t tg ii 78 y i= ; ,: : " u bE i = ii i 6. , ! i 9 t r c i r : = ;, .( , E E! P , i a e J' z o- , =. ! : . c r. ! O gb 6q o g ' . i : Tg : +. E ; ; I ! 2 .= l . ! ! : r a o : . _ - : ct ,E !l - \. 2 x= t: - Ue ! 4 ! : - . = - ; ! ! ,- E d i g i ; r t i S ' 6& : ; e E ; i ! i ! a sE E s i C : i : i i l = *! i [# : s il i z u {, P ;6 Ia r -! <. ; E - = Ei . = q E ' - ! il t ; 6E i I i E g g E i i i a 8E 8 r 8 . b P Pi : : l{ i s F E t H i. 5 ; i E 5 5 I 3 E e ! it = .; E= u 6E 9 i : ! = / ^e g s . e H b E H + * - : - T SE E i E ; E T: ; .9 >! 6; . 8 ! - ql E pt E r i j s r s 5! ; d" E ; P P E E i !; : FF v o : i = c! (, *: : ^ l- ^ r r . ' l + r o Xi t 6i o :i ! u' > E I: Y N -- j ;E-o > Ssrho.b. !D !E!\ a2 {oodoaoo-o!apoob 3Efoo)=!oEAogE-oF !rDo.occ.9 pEEaE.;Eco!i.go-EaE'iE EgEl!oo.Ec@(octstrE.ccq(. )@.Eo.EaE'i2q. ) lI39c5I(t )oo I6+;'6AcEE.goo- .c , .9 93o 16.Eoo-cEEo,oEazF -o a! r:6tF@t!c=!ooE.g o3EoF-d FzfozotraocooIoo5(. ) =ooEcEz9oo- rl il ltdtalaJc2Ec.Ec1oci qPccEIoEet -c ;i YXE5 5' , c! o LC>Eo- t5 =E o =. 9 E 9 2, tr . q ) - c I P' . 8 t: 6. P e 6q ) d oi ' E c ss Lg s, € 9 E: Ee S 3 Et r E E o! oE- o s E 81 5 € r r E? E P A o. ) c- E .: 5 i T E s u- E 6 E 5d r (] E !_ L: ! E 3; d t p S DO O A Y . .E Eb - ' : E 5. P * "E !D E5 " 9 h o _E 9e E P; E X } E ^- a! o2>s YJloozioJ(!.tEDOciobdc.9to-oIEiEooq3oa. !trEoE()EIoo- r" i 1daiFaEll oo2€t r ! -c Y > '' > !E i E Ib E l. - 5 t or i i- 3 b PE P L OL e; q t -o o ts f -f o 90 \J .c \l a. ! a - E qE 8: 8 .: 3. : E OE 5l J s e^ i e zz \\ tr ,ozIo(LoEr'coE!0g,Egi.9oo-EoIE9o'.E=ao.CrEoeo) I_ :s t ig s' q s* e r' E ; . ?= E 3E E '" 7 r$ g Ei E E : ;H ; S: : H ? ' iE : €E - a f i F E q t A Et i gE E Ig E g ,i 1g ; 5 - €# i E E 5 6: J E -o - q . , .9 r : E 9o iE o) <- 6E E E. 9 q 6E Eo g $ ;; i ; e r- $ [ g E t l Ei iZ e Z * Eg i ga € E ' Eg i? ! = E a E EE i ; i l x; ; * E ;; f l E 1 E[ i E E " E E 5i : ; EE E E , E; E i E ;E ; I E ; Et g E iA E rE E ii + l $ = do i . 5 9 F 5E g E- - : E e ES = i- g i I E ; [ [ B ' * E q t E r i ' EE ; $ $ Fg i Eg i E i Ei E ;i g $ $ - ^i "i ,' E i E . tr E Ad t qo ! S q I ROOF PLAN SCALE I' IO'.0" II ARRAY AND ROOF INFO rlsP s1E rS ^!lE)204 SUB S]ZE 6 AN LEI I25 A Arlra}./EMr potNTS rEiaG!.E rEi5 {?l rrrrc sLrrDorflr .€occ€r€{rs P€F t€€ 3 7 li* $--ro..vEr- i3 ^^a r^c:o. I MODULE TYPE, DIMENSIONS & WEIGHT I:{:{rt-+ :II 1 PA','A TYPE P^ris- t€lo{ PAI|A AFEA (r{T.r€rc+f. * Plr€Ls 'l /EAE9 t EaCXftC ,AEA P€R ATTAC}if,NT VI/EIC}'T PEF ATTA'*/EXT grfowER sPR{t}ID+r. trD arto _ x r7 56 3F autlt5. 233 O:I PsE /r)o 56 . t02 to rrctT - 71 61 SF LS !a ^'IACHrE tiT! oaa'oc ra\ 5 SOtIt raoorE5 !a fi^cHtf.xts {E' A.l,,6r€ rt lt €or, ciot6,6lC. AyEs.r I'lrc FLORES toqc souTr,r P^!LAD^Y STREET rccEfi€3 oEi?t'Eo ^;rE ^r 3-iora .o..ars o. aoo. {r,cF ao ior .^vE ot6xA6s acror uoo6 rcc6!3E3 .4. crc rtr.. t /BLIT sANrA AIA CA 9270t PV-2 rrror AzDrrnr llltiua 5a 4aT l^r YrQ.fT &flln 5rfc,a u3 @i?,sallrca! lo t9, at{lro c.c , PTOI AD|JB l3l IIII!trAI SP SQ-'T ATNAY SQFI RTFTB ITEC5c!|?.9{nctl !!t 14 zr o 2a o.c 1-.1' I I IlltItIlttlr E Site Plan for Small-Scale, Single,Phase PV Systems Site Nant: zos.nx'l^u-.oeysrEEE s.*raxra c^ elo, Sile Addrags: r pREg Syslem AC Size: rr.o tlv Dc arc rTs M IC}{O- I NVERTEI{ SITE I,LAN 2 F C! a o a- L 2 a- c f- c ioo r8f,A 2A2t+ tlcaqa ERrER II@AIEO AT EACH IP{'\E! I I J IrLl ll Fl i i I I I !l MICRO \CTRICAT I)IA(IRAN4 One.Line Standard Electrical Diagram for Micro-lnverter PV Systems ccr..,or ll.m, ,d INP,EI GrnOEll G,lo\/E. C,A l4air3 SitA l{8me: 2m BdnH }l^ruo y arE€r s rr^ aiA cr r,!7 Site AdHress ,.f,o^o.Es System AC Size: o toutPMtNr scHtDULt i rac ioEscRrPr|o lrvoc-mlrco,tr ]oorc rnvenrrn o.cnol fr.sgl rq gqlor 1^c co"" " *L lmseO Toei-fiffn]rr useor Irc usconxeci rr useor I9Elys . - --- I PART Ht,rlBER XOIES l#:=fr,q=. t 1I ?! 5_ 6 L a UIIUTY stRvtct i2{V C llhl.Ba S 12y1@ 1 SEE GUIDE APPE DIX O FOR INFORTTATIO}I O}I MODUTE ANO ARRAY GROUIDIt{G MICRO.INVERTERS III BRATCH ctRcutT IMICRO.IT{VERTERS BUILOING GROUNOING ELECTRODE FOR UNUSED T'ODULES PUT "N/A' 'n BIANK ABOVE A CONDUII AND CONOUcION sCHEDUTT IAG D€SCRIPTION OR COIIOUCTOR TYPE CONO NUMBER oF rcoxDutr lcoNDUtr I USg--z O o.-W vune f I c,aucsl comucronsf rver rrFG uFGCebb lrUA lt{/ArGECI EGCtr x AtL Ill,AT APPLY o 2 lN./A i_exrenron caaLe Lr.sreo nw flr- - j-*g I urc cauc ' vr IrI4'il.r a sllnttr tr gEH!t,s i i9E9 r EGc tr r A+ rHAr4l?lYi rt{O DC G€C lF 600.3t SYSTEIa Il-- I lTHlrri+2 I d XHlrritz O o.RHta*2D Ilorci- Ecc n x-er-r rrrer rppr,vl 10 6 !a'EuT I SAME SAI.IE I 5 6 I I o 1 oc )ocP INVtRTES ocPo MOO MOO l1 ry TT il IEgI I!1tl SAr!,lE 1!lE'tl SAME NT5 1 2 M MODL A A IN BRATCH. ctRcurI A A 3 1 NoTES FOR MICRO-INVERTER EI-EC]'RICAL DIACRAM Notes for On+.Line Standard Eleclrical Diagram for Single-Phase PV Systems c6!Eb. r5t Arr{rn Pncr oAFO€r Ofi.^/E. Cr nr/Xr Sitg ilanE: ,(osonxrarao y ancEr !r^xr^ rria c. sro, Site Address: ,.io'.*s Systern AC Size ...or*E src NI5 stcNs-stt GUtoE s€cllo 7 NOTES FOR ALI- ORA'AINGS I stGN toR oc otscoNNtcl PV MOOUII RAIINGS C sTC (6uide Section 5) SUNPOWER OCPD = OTr'ERCURREIr PROIECTION DEVICE NATIotrAj. ELECTRICAL cooE REFERENCES sHor i{ As rrvEc )oo(.)4, No sign necessary since 690.51 marrdru on PV mgdule cove6 needed iniormalionMODUTT MOOET SPR.E19.32O.D.AC tlAx Po!\ER-Potm CURRE T (*)5.86 MA)( POVIER.POINT VOLTAGE (VF)lrWRT[R RAIINGS (Guide s€ction 4) oPEll4tRCUrT VOLTAGE (Vc)N/A SIGH FOR II{VTRTTR OCPO AIID AC usco r{rCI (rr usED) sHoRT-CrRCUrr CURREt{r 0*)INVERITR MOOII N/A SOLAR PV SYSTEM AC POINT OF CONNECTION MAX SERIES FUSE (OCPO)iIAX DC VOLI RATING N/A 35.9'l l,tAxrMt,t, Po!!ER (Pqo 320 irAx PovrER @ 40'c NOMINAL AC VOLTAG N/A 240 E N/A THIS PANEL FEO 8Y MULTIPLE souRcES (uTrLrTY ANO SO|,.AR) i,lAX AC CURRENT N/A MAX OCPD RATING N/A NOTES FOR ARMY CIRCUIT l^,RI G (Gude Sedo.r 6 and I and Agperdir E)i{OIES FOR |i{VERT€R CIRCUIIS (Gu'de Sedtorl I arld 9) 1 ) LOII/EST EXPECT AMAIENT TEMPERATURE AASED ON ASHRAE MII{IMI,i' MEAN E,XTREME DRY BULE TET'PEMTUR€ FOR ASHME LOCATION ITOST SIMII-AR TO INSTALLATION LOCATION, LOVI'EST EXPECTEO AA.IBIENT TEMP 2 'C .l) rF LmLIY REOUTRESA VrS|BI-E-BREAX SllvTCH, OOES TH|S Sr/"rTC8 MEET THE REOUIREMET{T? YESE NOtr l{/A O 2) rF GEi{ERAIO|T UETER REQUTREO, OOES TH|S UETER SOCXET MEET THE REOUTREIaE}aT? YES O }{O O rUA El 3) S|ZE PHOTCVOTTATC POIA/ER SOURCE (DC) COITDUCTORS BASED Or{ t AX CURREMT ON }IEC 690,53 SIGX OR OCPD RATX{G AT DISCOT{NECT ,l) SIZE IifVERTER OUTRJT CIRCUTT (AC) COITDUCTORS ACCOROII{G TO |i{VERTER OCPO ATaPERE RAI}{G (S€e Glrro Secto.! 9) 5) TOTAL OF N IiIVERTER OUTPUT CIRCUIT OCPIX3) ONE FOR EACH UICRG I}{VERTER CIFUTIT mEs ToTAL SUPPIY BREAKERS id,PLY \MTH 120% sUssAR ExCEPTIOtt lx 89o 64(BX2X')? YESIS l{OO 2.) HTGHES] COr{TrNUOrrS AltBlErI TEITPERATURE EASED ON AS}|RAE HTGHEST iIOXTH 2% ORY BUI-B TETTPERATURE FOR ASHME LOCATIO TTOST $T IAR TO INSTAILAT|ON LOCATTON HTGHEST COi{TI{UOUS TEITPEMTURE !_'C 2 ) 2OOE ASHRAE FUNOAI'ENTAI-S 2% DESIGN IE PERATURES DO IIOT EXCEEO,rrc r THE UNTTEO STATES (PArfl SPRTNGS. CA rS +r 1'C) FOR |-ESS rlr,AN 0 CURREMT.CARRYI'{G CO}IOUCTORS IN ROOF{'OUNIED SUXUT COTIOUIT AT LEAST O 5- ABOVE ROOF ANO USING THE OUTDOOR D€SIGN TEXPERATURE OF 47"C OR LESS (AIL Of UI{IIED SIATES), A) I2 AIA/G, gOOC CO DUCTORS ARE GENERALLY ACCEPTAALE FOR MODULES \llTH lsc OF 7 0a ArrPS OR |ESS WHEX PROIECTED BY A t2.AlrP OR SIIAILER FUSE b) 10 A\AG COOC CONDUCTORS ARE GENEMLLY ACCEPTASLE FOR UOOULES WTH ls OF 0 6 A 4PS OR LESS r/YllEH PROTECTEO SY A 15-AMP OR S ATLER FUSE AC OU'IPUT CURRTNT NOMINAT AC VOTTAGI F Uc 1 L zc a- c F c E, 1643L- 14e xAx \DLTAGE (TYP 6oovo.) 160 vOC TErIP CoEFF (mvfoEl n "/6fcE, . {.3 lr*r**cg{,*!trL ,,,,'SANTA NA tll\\[6 & Bllt0t\c Act\cl Planning & Building Agency Building Safety Division 20 Civlc Center Plaza P.O. Box'1988 (M-19) Santa Ana, CA927O2 (714) 647-5800 www.santa-ana.org RESIDENT!AL PHOTOVOLTAIC CHECKLIST sol{1 cBC 2013 Solar Photovoltaic (PV, Checklist for Detached SINGLE FAMILY RESIDENCES Only lnstructions: The licensed contraclor of record shall fill in the address of the project, contractor's licensing information and answer questions 1 -10 below. Complete and sign the cerlification section "lf ansrlEring NO to any ofthe questions, plan check shall be required." Project Address:2OO9 SOUTH HALLADAY STREET SANTA ANA. CA 92707 contractor License Number. # 1008302 2 3 4 s Eltr9 Etr 10 EIE YES NOtrtr Etrtrtr trtr atr Are the following applicable to the proposed project? Will the PV anay be flush mounted to the existing roof so thal the plane of the modules (panels) are parallel to the plane of the roof? Wll the PV system weigh maximum 3 pounds per square feet or less? Wll the PV system be installed where lhe modules do nol overhang any roof edges (such as eaves, gabled ends, ridges and hips)? \Mll the PV system be installed with a space of 2' minimum to 10' maximum between the underside of modules and lhe surface of the roof? \Mll the PV system be installed without using any ballast system or counter-weight system? Vvill the PV system be installed on a roof having only one roofing layer with no overlays? Vvill the PV system layout provide a three-foot wide clear access pathway per lhe latest edition of 'Guideline tor Fire Satety Elements of Solar Photovoltaic Systems" by OCFA? (Guideline available on lhe OCFA website: hllor//www. ocfa.oro) Do the plans show a maximum horizontal anchor spacing of 6 feet? Do the plans show a minimum ot 2-112 inch lag screw embedment into roof raflers? Are ALL the strudural pages of the plans WET stamped and signed by a Califomia lic€nsed professional engineel? (including projecl specilic site plan, PV layout, anchorage spacing, anchorage details and manufadureis PV support information.) 6 7 Btr trtr I certify under penalty of pedury underthe laws of the State of Califomia that the above is true: print name: JULIO FLORES Signatu re Phone Number: Email Address: Re'l:2117DO15 (7 r4\ 370-8877 Date: 2l 20r8 Contractor Company Name: STAR SUN SOLAR